8/18/2019 mc-dptac http://slidepdf.com/reader/full/mc-dptac 1/20 Premium Amana ®  Brand Quality Web-Based Monitoring Wise Decision. It’s an Amana ®  brand. Amana is a registered trademark of Maytag Corporation or its related companies and is used under license to Goodman Company, L.P., Houston, TX, USA. All rights reserved. Featuring DigiSmart ® PACKAGE TERMINAL AIR CONDITIONER (PTAC)  AND HEAT PUMP Specifications and Accessories Catalog
Transcript
Page 1: mc-dptac

8182019 mc-dptac

httpslidepdfcomreaderfullmc-dptac 120

Premium Amanareg Brand Quality

Web-BasedMonitoring

Wise Decision

Itrsquos an Amanareg brand

Amana is a registered trademark of Maytag Corporation or

its related companies and is used un der license to Goodman

Company LP Houston TX USA All r ights reser ved

FeaturingDigiSmartreg

PACKAGE TERMINAL AIR CONDITIONER (PTAC) AND HEAT PUMP

Specifications and Accessories Catalog

8182019 mc-dptac

httpslidepdfcomreaderfullmc-dptac 220

DIGISMARTreg

A Combination of Energy Management and PTAC Performance

Amanareg brand DigiSmartreg brings together our best PTAC with our best energy management sofware that now integrates

with optional property management and ront desk management sofware Reduce PTAC energy consumption up to

35 OR MORE through the power o the in-unit energy management system programmable temperature set-back and

temperature limiting combined Our Maintenance Notification System can alert when there is a potential maintenance

issue with the PTAC

Amana brand DigiSmart SolutionI n -R o o m Self - I n s t al lable W ireles s Peripherals

The DigiSmart Wireless Remote

Thermostat can be mounted on the

wall anywhere in the guest room It is

Battery powered and with its own wire-

less ability to communicate with the

PTAC to maintain room temperature

Best of all there are no wires to run The PTAC and thermostat

connect at the press of a button and work in-sync to display

accurate temperature

The DigiSmart Occupancy Sensor

and Door Switch Combo Device

completes the in-room equipmentThis inrared sensor can determine

whether the room is occupied or

empty and when empty signal the PTAC to adjust the tem-

perature to save energy based on programmable set-backs

The DigiSmart Wireless Antenna

installs inside the PTAC with a snap-in

connector like a telephone jack In-

stalling the antenna allows the PTAC

to communicate wirelessly with other

devices in the room and to the DigiSmart network

60000+ rooms have had wireless installations

since 2005

Total wireless devices deployed to date 425000+

The Amana brand DigiSmart PTAC with antenna combined

with the self-installable wireless thermostat and occupancy

sensor give the property owner complete control over the

equipment settings and can reduce PTAC energy usage up

to 35 OR MORE

Site-Level mdash Central Wireless Controller

Site-wide PTAC Coniguration

Site-wide PTAC Diagnostics

Front-Desk System Interace

Email Reporting

Internet Accessible Web User Interace Enterprise

DigiSmart

Controller

These savings represent estimated savings over time and were generated using generalassumptions including energy loads local weather averages and use o occupancy controlsActual savings will vary according to actual use habits room square ootage and how the

unit is installed and maintained

8182019 mc-dptac

httpslidepdfcomreaderfullmc-dptac 320

3

Talk to your Amana brand dealer about opportunities to optimize the efficiency

of your new unit Before purchasing this appliance read important information

about its estimated annual energy consumption yearly operating cost or energy

efficiency rating that is available rom your dealer

wwwamana-ptaccom

wwwamana-ptaccom

Site 1 Site 2 Site 3

Internet

DigiSmartController

DigiSmartController

DigiSmartController

Maintenance Staff

Owner

Front Desk Staff General Managers

E n t e r p

r i s e o r

S i g n a l

S i g n a l

Data Warehouse Site Managment

P l a t f o r m

A c c e s s

E nt e r p r i s e o r P l at f o r m A c c e s s

Web-Based Monitoring ndashAmanareg brand DigiSmartreg ControllerAll PTACs in a building can be managed

through a single interace on a PC

Features Include

Full unit details or every PTAC visible rom the ront

desk or home oice

Automatic emails or PTAC maintenance

Ability to change all settings on the unit

Enhanced diagnostics

Monitors up to 170 PTACs WIRELESSLY with

one controller

Expand the network with additional controllers

ndash System Veriication ndash Site Statistics

ndash Global Setbacks ndash Email Reporting

ndash EMS Coniguration ndash Unit Health

ndash Site Statistics ndash Unit Code Alerts

Unrented Set-Points

By integrating with your propertyrsquos Front Desk System

the PTACs will adjust to specific set-points when no longer

identiied as rented in the system

Temp Limiting

Each PTAC can be configured with a heating and cooling

temperature set-point limit

Set-backs

Once a room is declared unoccupied by the occupancy

sensor the PTAC progresses through three different tem-

perature set-backs configured as three degree and time

pairs (An example coniguration is listed below)

1 2deg 30 mins ndash Setback the temp 2 degrees

ater 30 minutes

2 4deg 1 hr ndash Setback the temp 2 more degrees

ater 30 more minutes

3 8deg 3 hrs ndash Setback the temp 4 more degrees

ater 2 more hours

Enterprise ndash Multiple Wireless Controllers

Central Monitoring and Control o Multiple Properties

Data Warehousing

Virtual Metering

Savings Analysis

Load Shedding

Email Reporting

8182019 mc-dptac

httpslidepdfcomreaderfullmc-dptac 420

4 wwwamana-ptaccom

Standard Features Energy Efficiencies With EERs up to 120 and COPs

up to 34 our unitrsquos high eiciencies may qualiy

you or many o the rebates oered by electrical

power companies

Quiet Operation Our PTAC has been redesigned to be

the quietest PTAC wersquove ever built The unitrsquos state-

o-the-art design and construction provide a quiet

environment allowing guests to enjoy peaceul

sleep-illed nights

ndash Two an motors (indooroutdoor)

ndash Indoor tangential an or quiet operation

ndash STC o 28

Assembled in the USA for 35 years assembled at our

plant in Fayetteville TN using Goodman resources

including engineering production and testing

Increased Dehumidification Capacity Maintain lower

humidity levels in rooms while cooling them without

the need or expensive add-ons As a result guests eel

more comortable at higher temperatures thus

reducing cooling costs

Seven-Button Touch Pad Provides complete control

to guests or in-room comort while maintaining

energy e iciency

Five-Year Limited Warranty Enjoy one o the most

comprehensive warranties in the industry First Year

parts amp labor Second through ith years parts

amp labor on certain sealed system components

second through ith years on certain unctional

parts only For complete warranty details visit

wwwamana-ptaccom

100 Run Tested All units are 100 run tested atour plant in Fayetteville TN including leak checks

during manuacturing and again prior to shipment

at the warehouse

7⅝ Unit Front Depth Enhance valuable room

space with our slim unit ront which has a sleek

7⅝ depth one o the shallowest silhouettes in

the industry today In addition to inhibit guest-

tampering the ront can be secured to the chassis

with a hidden screw

Easy Pull-Out Filters Our ilters are washable and

easy to maintain

Filter Dryer for Sealed System Refrigerant Standard

in all units to protect the compressor and lengthen the

lie o the unit by removing moisture and preventing

acid ormation

Condensate Dispersion System Our condensate

dispersion system removes condensate rom indoor

cooling operation by throwing water directly on to

the outdoor coil or rapid evaporation and increased

cooling eiciencies The slinger ring on the new

enhanced an draws water up and into the an blades

This water is then atomized and evaporated into the

atmosphere through the condenser Increased surace

area rom the coil allows more water to be evaporatedon the sides o the coils and helps to minimize

condensate run-o

Front Desk Control Each unit comes equipped with

the DigiSmarttrade control and energ y management

sotware Using the DigiSmarttrade sotware and optional

RF Antenna all units can be wirelessly connected

to a central hub or enhanced energy savings and

diagnostics Amana brand PTACs also have a low-

voltage interace capability with a ield-supplied

ront-desk ONOFF switch (See inside ront cover)

8182019 mc-dptac

httpslidepdfcomreaderfullmc-dptac 520

5Specifications and Accessories Catalog

Room Freeze Protection When the unit senses

temperatures o 40degF or below the unit activates

the an motor and either the electric resistance

heater or the hydronic heater

Easy-to-use Controls No complex controls to conuse

your guests and create phone calls or your manager

Controls are easy to read understand and activate

Our new 7-button control panel provides guests with

complete control o the unit or their in-room comort

while maintaining overall energ y e iciency

Easy to Service with On-Board LED Diagnostics

The main components are easily serviced and there

is no guessing to determine the problem with our

easy-to-read diagnostics

Stonewood Room Front Our Stonewood room ront

strikes the balance between attractive st yling and

practical design Distinctive contours and a modern

appearance enhance the character o even the most

luxurious room while the sleek 7⅝ depth maximizes

usable space or your guests

Remote Thermostat Control When the DigiSmarttradewireless remote thermostat (DS01E sold separately) is

set up both the remote thermostat and unit control

panel continue to control the unit providing lexibility

and home-like system control Installation requires no

more than pressing two buttons No need to run wires

or make electrical connections

Extended Heat Pump Heating Heat pump models

will operate in the heating mode down to as low as

24degF outdoor ambient temperature

Zero Floor Clearance The unit can be installed lush

to a inished loor i desired (Some accessories do

not have zero clearance)

30-Second Fan-Off Delay The an continues to run

30 seconds ater the compressor has stopped in either

cooling or heat pump mode and ater electric heat has

been turned o This improves eiciency by dispersing

the conditioned air on the coils into the room

Compressor Lock-In This eature helps prolong the lie

o the compressor by preventing short-cycling When

the compressor is switched rom O to On because

room temperature has risen or allen below the

speciied limit it will remain on or at least 4 minutes

I the temperature set-point is changed during this4 minutes the lock-in eature is overridden

Automatic Emergency Heat No more ldquomy unit is not

heatingrdquo complaints during the middle o the night

Heat pump units will automatically switch over to

electric resistance heat i the heat pump compressor

system ails or i the heating load is greater than the

unit capacity

Constant Fan Mode Take advantage o each unitrsquos

dual options mdash select continuous an operation or

cycle the an ON and OFF with the thermostatOur 7-button design allows guests to select an

perormance while allowing the owner to have the

unit revert to the desired program o continuous

an or cycle with conditioning

Hidden Ventilation Control The ventilation control

lever is hidden rom the occupants view to allow you

to manage ventilation requirements

High-Pressure Switch Protects the unit rom high

pressure and damage to the unit helping to ensure

long unit lie

8182019 mc-dptac

httpslidepdfcomreaderfullmc-dptac 620

6 wwwamana-ptaccom

Nomenclature

123 45 6 7 89 1415

Basic Model Type Engineering

PTC Standard Cooler PTAC Major amp Minor Revisions

PTH Standard Heat Pump PTHP

DRY Dehumid Cooler PTAC Features Code

PMC DigiAIR Cooler PTAC A Standard Model

PMH DigiAIR Heat Pump PTAC C Corrosion Protection (Seacoast)

D Power Door

Nominal Cooling Capacity F Fuse Holder (230208 Only)

07 7000 BTUh 60 Hz L Lighting Control

09 9000 BTUh 60 Hz H Hydronic Heat-Capable

10 10000 BTUh 50 Hz P Condensate Pump (PTH Only)

12 12000 BTUh 50 or 60 Hz Q Quiet STC 31 Chassis

15 15000 BTUh 60 Hz R RF Antenna

17 17000 BTUh 60 Hz V Power Vent

X placeholder

Rated Voltage W Hard-Wired (PTQC)

2 115V 60 Hz 1 Phase

3 230208V 60 Hz 1 Phase Heater Size

4 265V 60 Hz 1 Phase 00 No Electric Heat 35 35 kW (230208V)

5 240220V 50 Hz 1 Phase Export 15 15 kW 37 kW (265V)

25 25 kW 50 50 kW

Design Series

G R-410A Use up to 4 as needed in alphabetical order Examples

PTC12350AXXX PTC07335CRXX

PTC12350CXXX PTC07325CQRW

AXXX AA

10111213

PTC 07 3 G 35

Power Cord Configuration

Power Receptacle Configuration

NEMA6-15R 250V

receptacle used on

230208V units

NEMA6-20R 250V

receptacle used on

230208V units

NEMA6-30R 250V

receptacle used on

230208V units

NEMA7-20R 277V receptacle

used on 265V units

NEMA7-30R 277V receptacle

used on 265V units

G

W

20 amp

G W

30 amp

15 amp 20 amp 30 amp

277V Rating Power Cord Plugs

NEMA 7 Configuration

250V Rating Power Cord Plugs with LCDI Device

NEMA 6 Configuration

Power Cord Plugs

All units come with factor-installed power cords

All units less than 250 volts come with LCDI device

8182019 mc-dptac

httpslidepdfcomreaderfullmc-dptac 720

7Specifications and Accessories Catalog

Product Speciications PTC Models mdash CoolingElectric Heat230208 Volts

Model 983094 983096 983097PTC

073GXXXPTC

093GXXXPTC

123GXXXPTC

153GXXXPTC

173GXXX

Voltage 983219 230 208 230 208 230 208 230 208 230 208Capacity (BTUh) 7700 7700 9000 9000 12000 11700 15000 14700 16400 16200Amps 983225⁰ 35 35 41 41 56 56 70 70 84Watts 983225⁰ 658 658 796 783 1114 1085 1500 1470 1740 1720EER 117 117 113 115 104 105 100 100 94

Unit without Electric Heater

Min Circuit Amps 983090 983092 983089983088 42 49 68 85 102

CFM (CoolWet Coil)High 290 290 290 340 340Low 264 264 264 314 314

CFM (Dry Coil)

High 310 310 310 360 360

Low 282 282 282 332 332Ventilated Air CFM (Fan Only) 65 65 65 65 65Dehumidification (PintsHr) 17 22 36 44 48Net Weight (lbs) 98 102 102 113 113Ship Weight (lbs) 113 117 119 130 130

265277 Volts

Model 983089 983094 983096PTC

074GXXXPTC

094GXXXPTC

124GXXXPTC

154GXXX

Voltage 983225 983219 265 265 265 265Capacity (BTUh) 7700 9000 12000 14800Amps 983225⁰ 30 36 48 60Watts 983225⁰ 658 796 1154 1480EER 117 113 104 100

Unit without Electric Heater

Min Circuit Amps 983090 983092983089983088 36 44 59 74

CFM (CoolWet Coil)High 290 290 290 340Low 264 264 264 314

CFM (Dry Coil)High 310 310 310 360Low 282 282 282 332

Ventilated Air CFM (Fan Only) 65 65 65 65Dehumidification (PintsHr) 17 22 36 44Net Weight (lbs) 98 102 102 113Ship Weight (lbs) 113 117 119 130

Actual vent CFM perormance will vary due to application and installation conditions

N983151983156983141983155983225 All 265-volt models must use an Amanareg brand sub-base (PTSB4E) or an Amanareg brand hard-wire kit PTPWHWK4 and

disconnect switch PSHW04A

983218 Minimum Circuit Ampacity (MCA) ratings conorm to the National Electric Code however local codes should apply

983219 Minimum voltage on 230208-volt models is 197 volts maximum is 253 volts Minimum voltage on 265-volt models is 239 volts

maximum is 292 volts⁴ Overcurrent protection or all units without electric heaters is 15 amps Overcurrent protection on 265-volt models must be

cartridge-style time-delay uses (included and actory-installed on all Amana reg brand 265-volt chassis) See heater perormance

⁵ Heating capacity and efficiency based on unit operation without condensate pump unit automatically switches to electricheat at approximately 24degF outdoor ambient

⁶ Speciy two-digit heater kW size to complete model number

⁷ R-410A rerigerant used in all systems

⁸ All units meet or exceed ASHRAE 901 standards

⁹ All units less than 250 volts have a Leak Current Detector Interrupter (LCDI) power cord and meet UL 484 standards

983225⁰ Reer to electric heat perormance data or total MCA and recommended overcurrent protection Amps and Watts notationreers to compressor only

8182019 mc-dptac

httpslidepdfcomreaderfullmc-dptac 820

8 wwwamana-ptaccom

Product Speciications PTH Models mdash CoolingHeat PumpElectric HeatM983151983140983141983148 983089 983094 983096 983097

PTH073GAXXX

PTH093GAXXX

PTH123GAXXX

PTH153GAXXX

PTH074GAXXX

PTH094GAXXX

PTH124GAXXX

PTH154GAXXX

Voltage 983225 983219 230 208 230 208 230 208 230 208 265 265 265 265

Capacity (BTUh) 7600 7600 9000 900012000 12000

14700 14700

7600 9100 12000 14600

Amps 983225⁰ 39 39 42 42 58 58 70 70 31 37 50 61

Watts 983225⁰ 650 633 750 750 1090 1090 1515 1515 650 758 1091 1505

EER 117 120 120120 110110 97 97 117 120 110 97

U983150983145983156 983159983145983156983144983151983157983156 E983148983141983139983156983154983145983139 H983141983137983156983141983154

Min Circuit Amps 983090 983092983089983088 47 51 71 85 38 45 61 74

CFM (CoolWet Coil) High 340 330 340 390 340 330 340 390Low 245 245 245 340 245 245 245 340

CFM (Dry Coil)High 370 360 370 410 370 360 370 410

Low 270 270 270 370 270 270 270 370

Ventilated Air CFM (Fan Only) 65 65 65 65 65 65 65 65

Dehumidiication (PintsHr) 17 22 36 44 17 22 36 44

Net Weight (lbs) 108 112 115 126 108 112 115 125

Ship Weight (lbs) 123 127 132 143 123 127 132 142

Actual vent CFM perormance will vary due to application and installation conditions

N983151983156983141983155983225 All 265-volt models must use an Amanareg brand sub-base (PTSB4E) or an Amanareg brand hard-wire kit (PTPWHWK4)983218 Minimum Circuit Ampacity (MCA) ratings conorm to the National Electric Code however local codes should apply

Minimum voltage on 230208-volt models is 197 volts maximum is 253 volts983219 Minimum voltage on 265-volt models is 239 volts maximum is 292 volts⁴ Overcurrent protection or all units without electric heaters is 15 amps Overcurrent protection on 265-volt models must be

cartridge-style time-delay uses (included and actory-installed on all Amanareg brand 265-volt chassis)⁵ Heating capacity and efficiency based on unit operation without condensate pump unit automatically switches to electric

heat at approximately 24degF outdoor ambient⁶ Speciy two-digit heater kW size to complete model number⁷ R-410A rerigerant used in all systems⁸ All units meet or exceed ASHRAE 901 standards⁹ All units less than 250 volts have a Leak Current Detector Interrupter (LCDI) power cord and meet UL 484 standards983225⁰ Reer to electric heat perormance data or total MCA and recommended overcurrent protection Amps and Watts notation

reers to compressor only

8182019 mc-dptac

httpslidepdfcomreaderfullmc-dptac 920

9Specifications and Accessories Catalog

Actual vent CFM perormance will vary due to application and installation conditions

N983151983156983141983155983225 Minimum Circuit Ampacity (MCA) ratings conorm to the National Electric Code however local codes should apply983090 Minimum voltage on 115-volt models is 109 volts maximum is 127 volts983091 Overcurrent protection or all units without electric heaters is 15 amps⁴ R-410A rerigerant used in all systems

⁵ All units meet or exceed ASHRAE 901 standards⁶ All units less than 250 volts have a Leak Current Detector Interrupter (LCDI) power cord and meet UL 484 standards

M983151983140983141983148 983093 983094PTC

072GXXXPTC

092GXXX

Voltage 983090 115 115

Capacity (BTUh) 7000 9000

Amps 69 83

Watts 585 795

EER 119 113

Min Circuit Amps 983089 983091 83 101

CFM (CoolWet Coil)High 290 290

Low 264 264

CFM (Dry Coil)High 310 310

Low 282 282

Ventilated Air (Fan Only) 65 65

Dehumidiication (PintsHr) 17 23

Net Weight (lbs) 98 102

Ship Weight (lbs) 113 117

Product Speciications PTC 115-Volt Models mdashCoolingHydronic Heat or No-Heat Models

8182019 mc-dptac

httpslidepdfcomreaderfullmc-dptac 1020

10 wwwamana-ptaccom

Product Speciications PTH Models mdash Reverse-Cycle Heating PerormanceH983141983137983156983145983150983143

C983137983152983137983139983145983156983161983225PTH073G

AXXXPTH093G

AXXXPTH123G

AXXXPTH153G

AXXXPTH074G

AXXXPTH094G

AXXXPTH124G

AXXXPTH154G

AXXX

Voltage 983225 983219 230 208 230 208 230 208 230 208 265 265 265 265

BTUh ⁵ 6800 6800 8300 8100 11500 11300 13800 13600 6800 8300 11400 13700

Amps 983225⁰ 39 39 42 42 58 58 70 70 31 37 50 61

Watts 983225⁰ 585 585 715 700 1085 1035 1350 1330 585 715 1080 1340

COP ⁵ 34 34 34 34 31 32 30 30 34 34 31 30

CFM (Dry) 370 360 370 410 370 360 370 410

COP = Coefficiency o Perormance per AHRI Test Procedures units are rated or capacities and efficiencies

N983151983156983141983155

983225 All 265-volt models must use an Amanareg brand sub-base (PTSB4E) or an Amanareg brand hard-wire kit (PTPWHWK4)983218 Minimum branch circuit ampacity ratings conorm to the National Electric Code however local codes should apply983219 Minimum voltage on 230208-volt models is 197 volts maximum is 253 volts

Minimum voltage on 265-volt models is 239 volts maximum is 292 volts⁴ Overcurrent protection or all units without electric heaters is 15 amps Overcurrent protection on 265-volt models must

be cartridge-style time-delay uses (included and actory-installed on all Amanareg brand 265-volt chassis)⁵ Heating capacity and efficiency based on unit operation without condensate pump unit automatically switches to electric

heat at approximately 24degF outdoor ambient⁶ Speciy two-digit heater kW size to complete model number⁷ R-410A rerigerant used in all systems⁸ All units meet or exceed ASHRAE 901 standards⁹ All units less than 250 volts have a Leak Current Detector Interrupter (LCDI) power cord and meet UL 484 standards983225⁰ Reer to electric heat perormance data or total MCA and recommended overcurrent protection

Amps and Watts notation reers to compressor only

Product Speciications PTC PTH Models mdash Electric Heat Perormance(Primary Heating or PTC Models Auxiliary Heating or PTH Models See below or Power Cord Coniguration)

V983151983148983156983137983143983141E983148983141983139983156983154983145983139H983141983137983156983141983154

S983145983162983141 (983147W)

N983151 983151983142S983156983137983143983141983155

N983151983149983145983150983137983148 H983141983137983156983145983150983143 (BTU983144)T983151983156983137983148

W983137983156983156983155983094T983151983156983137983148 A983149983152983155

M983145983150 C983145983154983139983157983145983156 A983149983152983137983139983145983156983161983218

MOP983092(983137983149983152983155)

P983151983159983141983154C983151983154983140

10486269830911048624V 104862610486241048632V 104862610486301048629V

230208V 15 13 1 5100 4200 - - 1570 1295 68 62 85 15 6-15 P

230208V 25 21 1 8500 6800 - - 2570 2115 112 101 141 15 6-15 P

230208V 35 30 1 12000 9900 - - 3570 2935 155 141 195 20 6-20 P

230208V 50 41 1 17100 14000 - - 5070 4160 221 200 276 30 6-30 P

265V 15 1 - - - - 5100 1570 59 74 15 7-20P

265V 25 1 - - - - 8500 2570 97 122 15 7-20 P

265V 37 1 - - - - 12600 3770 142 179 20 7-20 P265V 5 1 - - - - 17100 5070 192 239 25 7-30 P

N983151983156983141983155983225 All 265-volt models must use an Amanareg brand sub-base (PTSB4E) or an Amanareg brand hard-wire kit (PTPWHWK4)983218 Minimum branch circuit ampacity ratings conorm to the National Electric Code however local codes should apply983219 Minimum voltage on 230208-volt models is 197 volts maximum is 253 volts Minimum voltage on 265-volt models is 239 volts maximum is 292 volts⁴ Overcurrent protection or all units without electric heaters is 15 amps Overcurrent protection on 265-volt models must be cartridge-style

time-delay uses (included and actory-installed on all Amanareg brand 265-volt chassis)⁵ Heating capacity and efficiency based on unit operation without condensate pump unit automatically switches to electric heat at

approximately 24degF outdoor ambient⁶ Total watts or 15000 BTUh models subtract 20 watts or PT070912⁷ Speciy two-digit heater kW size to complete model number⁸ R-410A rerigerant used in all systems⁹ All units meet or exceed ASHRAE 901 standards983225⁰ All units less than 250 volts have a Leak Current Detector Interrupter (LCDI) power cord and meet UL 484 standards

8182019 mc-dptac

httpslidepdfcomreaderfullmc-dptac 1120

11Specifications and Accessories Catalog

AccessoriesW983137983148983148 S983148983141983141983158983141983155All our wall sleeves have industry standard dimensionso 42 wide x 16⅟ ₁₆ high The WS900E SC and INTERNAL14⅛ depth is the industry standard Sleeves maybe shipped separately to allow or installationduring construction

C983151983150983140983141983150983155983137983156983141 D983154983137983145983150 K983145983156Attaches to the wall sleeve base pan or controlledinternal or external disposal o condensate

L983151983159983085V983151983148983156983137983143983141 W983145983154983141 H983137983154983150983141983155983155 K983145983156 (983150983151983156 983155983144983151983159983150)For quick connections o the remote or wiredthermostats wired EMS or ront desk with jumpers andconnectors

R983141983149983151983156983141 E983155983139983157983156983139983144983141983151983150 K983145983156 (983150983151983156 983155983144983151983159983150)Optional kit or use with units controlled via a wiredremote thermostat Covers control touch-pad or wiredthermostat installations

Each ldquoBrdquo kit contains 80 wires and wire nutsenough to attach a thermostat and oneadditional accessory to 10 PTAC units Wirescome in assorted colors or easy attachmentEach ldquoArdquo kit contains 10 Escutcheon plates only

O983157983156983140983151983151983154 G983154983145983148983148983141983155Available in stamped-aluminum or architecturallylouvered or application with an Amana brand WS900Ewall sleeve

AGK Extruded aluminum architectural grille availablewith anodized aluminum inish or a baked-on paintinish or durability Choose rom 3 stock colors or acustom color to blend with your buildingrsquos exteriorcolor scheme Colors include

CB (Clear Anodized) DB (Dark BrownBronze)TB (Stonewood Beige) WB (White)SB (SpecialCustom Colors)

PGK One-piece injection molded grille using a polymerblend o engineered thermoplastic high-impactstrength material with chemical resistance andan exterior UV protective coating

Choose from 3 stock colorsDB (Dark BrownBronze) TB (Stonewood Beige)

WB (White)

S983156983137983150983140983137983154983140983085D983141983152983156983144 S983148983141983141983158983141983155

WS900E-GS Heavy Sound Isolation Insulation Sleeve

WS900E Standard PTAC sleeve

WS900SC Seacoast triple protected

WS900D-INTERNAL

Internal drain only or window-wallinstallations (DK900D sold separately)

E983160983156983154983137 D983141983141983152 S983148983141983141983158983141983155 in several depths orthicker wall installations or special roomconigurations

WS9XXD1 16 to 24 in 1 increments

WS928D1 Extra deep 28

WS930D1 Extra deep 30

WS936D1 Extra deep 36

WS9XXD1-Interna

Extra deep Internal drain onlyor window-wall installations(DK900D sold separately) 1 4

⅛ 4 2

1 6

1

1 6

S983156983137983150983140983137983154983140 O983157983156983140983151983151983154 G983154983145983148983148983141

SGK01B Single Pack

SGK01TB Stonewood Beige

A983154983139983144983145983156983141983139983156983157983154983137983148 O983157983156983140983151983151983154 G983154983145983148983148983141

AGK01CB Anodized Aluminum

AGK01DB Dark BronzeBrown

AGK01TB Stonewood Beige

AGK01WB Amana White

AGK01SB Custom Colors

PGK01DB Dark BronzeBrown

PGK01TB Stonewood Beige

PGK01WB Amana White

AGKor

PGK

SGK

DK900DCondensate Drain Kit(use with WS900E)

DK9001DCondensate Drain Kit(use with WS900B)

DK900D

PWHK01C Wire Harness Kit

REK10BRemote Escutcheon Kit(10-pack)

REK10A Remote Escutcheon Plates

8182019 mc-dptac

httpslidepdfcomreaderfullmc-dptac 1220

12 wwwamana-ptaccom

Accessories (cont)S983157983138983085983138983137983155983141 K983145983156The ully skirted sub-base conceals wiring whileproviding strong support i needed Plug-in receptacleand ield-wiring access speeds installation Electricalaccessories such as use holders circuit breakers anddisconnect switches meet NEC requirements

L983141983158983141983148983145983150983143 L983141983143983155Gives wall sleeve ront support and helps to level theunit or installation

H983137983154983140983085983159983145983154983141 K983145983156983155Used to permanently wire to the chassis when astandard sub-base and power cord are not utilized

F983137983139983156983151983154983161 I983150983155983156983137983148983148983141983140 Feature Code - W

P983151983159983141983154 D983145983155983139983151983150983150983141983139983156 S983159983145983156983139983144The PSHWA power disconnect switch can be usedor 265-volt or 230208-volt physical disconnectwhere required by local codes The switch is ratedat 30-amp capacity The switch is or use with andAmanareg brand standard sub-bases or PTPWHWK4Hard Wire Kit

F983157983155983141 H983151983148983140983141983154 K983145983156Cartridge-style uses can be installed in the useholder or use in the sub-base or chassis Available in15 20 and 30 amp (included on 265-volt unit)

C983145983154983139983157983145983156 B983154983141983137983147983141983154 K983145983156 (983090983091983088983090983088983096V 983151983150983148983161)The circuit breaker kit available in 15 20 or 30 ampcan be used with Amana brand sub-bases It givesovercurrent protection and its location allows you toturn the unit on or off without tools

PTSB215E 115V15A

PTSB320E 230208V 1520A

PTSB330E 230208V 30A

PTSB420E 265V 1520A

PTSB430E 265V 25A

PTSB000E Non-electrical

LL2B Leveling legs or WS9 sleeves

PTPWHWK4 Armored Cable ndash all voltages

PTQC3A Quick Connect ndash 230208V

PTQC4A Quick Connect ndash 265 amp 115 V

PSHW03A 230208V

PSHW04A 265V

FHK315E 230208V 15A

FHK315E 230208V 15A (R-410A)

FHK320C 230208V 20A

FHK320E 230208V 20A (R-410A)

FHK330C 230208V 30A

FHK330E 230208V 30A (R-410A)

CBK15C 15 amp Circuit Breaker Kit

CBK20C 20 amp Circuit Breaker Kit

CBK30C 30 amp Circuit Breaker Kit

8182019 mc-dptac

httpslidepdfcomreaderfullmc-dptac 1320

13Specifications and Accessories Catalog

Accessories (cont)

P983151983159983141983154 V983141983150983156 K983145983156Installation o Power Vent increases CFM up toapproximately 95 Vent door will automatically closewhen unit an is off

F983137983139983156983151983154983161 I983150983155983156983137983148983148983141983140 Feature Code - VR-410A models must have these kits installed atthe actory

C983151983150983140983141983150983155983141983154 B983137983142983142983148983141 K983145983156For use on non-baffled grilles These delectors directthe air in toward the center and away rom the inlet toprevent recirculation o the hot condenser air

S983157983138983085983138983137983155983141 E983160983156983141983150983155983145983151983150 C983151983158983141983154 K983145983156Converts older 30-amp sub-bases to allow or installationo the larger 30-amp LCDI power cord and plugs

S983141983139983157983154983145983156983161 K983141983161 L983151983139983147983155In conjunction with the tamper-resistant ront theinstallation o Amanareg brand security key locks preventstampering o the controls used to set temperature heatingand cooling unctions UL approved or institutionaluse only

C983151983150983140983141983150983155983137983156983141 R983141983149983151983158983137983148 P983157983149983152Can be ield-installed Assists in removing condensatedeveloped by heat pump operation and transers it to

indoor coil to dissipate into room while adding humidityto the room

F983137983139983156983151983154983161 I983150983155983156983137983148983148983141983140 Feature Code - P

PVK3A 230208V ndash R-22

PVK4A 265V ndash R-22

D983157983139983156 E983160983156983141983150983155983145983151983150 K983145983156Extends air distribution to an adjoining room Consistsof a main duct for the room of origin and an extensionduct to reach the adjoining room and terminal ductPTDK01A allows for the ldquoBrdquo series unit to work with theldquoArdquo series duct kits

MDK02B Main Duct ndash R-22

MDK01E Main Duct ndash R-410A

EDK02B 42 Extension Duct

TRANSITION BAFFLES

Main Duct Kit

TDK02B Terminal Duct

PTDK01A Transition Duct Only ndash R-22

PTDK01E Transition Duct Only ndash R-410A

Extension Duct Kit

Terminal Duct Kit

DGK1B Condenser Baffle Kit

SBEC10A 10 Pack

Basepan

Condenser

Condenser Baffles

KL03B Security Key Lock (R-22)

KL03E Security Key Lock (R-410A)

CDP302 230208V ndash R-22

CDP402 265V ndash R-22

CDP303E 230208V ndash R-410A

8182019 mc-dptac

httpslidepdfcomreaderfullmc-dptac 1420

14 wwwamana-ptaccom

Accessories (cont)

HWK03B Hydronic Water Kit ndash R-22

HVK03B Hydronic Steam Kit ndash R-22

HWK03E Hydronic Water Kit ndash R-410A

HVK03E Hydronic Steam Kit ndash R-410A

ThermostatsThe ollowing thermostats offer remote control Any thermostat other than those listed must be submitted to Goodman Company LPor approval prior to use

H983161983140983154983151983150983145983139 H983141983137983156 K983145983156Add-on kits it all units allowing the addition o hydronicwater or hydronic steam heat to cooling and heating unitsThe kits eature lef- or right-hand piping Unit retainscomplete service access with a kit installed Unit must beconnected to and operated by a wall thermostat

Hydronic Heat Kit Top View

Hydronic Heat Kit Right View

M983151983140983141983148 H983141983137983156 S983156983137983143983141983155 C983151983151983148 S983156983137983143983141983155 F983137983150 S983152983141983141983140 983151983142 W983145983154983141983155R983141983153983157983145983154983141983140

T983141983149983152L983145983149983145983156983145983150983143

B983137983139983147983148983145983156 D983145983155983152983148983137983161 T983161983152983141S983144983137983152983141 983078

O983154983145983141983150983156983137983156983145983151983150C983151983150983150983141983139983156983145983151983150

2246002 1 1 1 5 No Yes Digital Manual RectHoriz Wired

2246003 2 2 2 7 Yes Yes Digital Manual RectHoriz Wired

2246007 2 2 1 7 Yes Yes Digital Auto-Change RectHoriz Wired

2246008 2 2 1 7 Yes Yes Digital Programmable RectHoriz Wired

DS01E 2 2 2 0 Yes Yes Digital Manual RectHoriz Wireless

Battery powered but has optional hard wire capability Requires DT01G Antennae or operation

Hydronic Heat KitSide View

8182019 mc-dptac

httpslidepdfcomreaderfullmc-dptac 1520

15Specifications and Accessories Catalog

Accessories (cont)P983151983159983141983154 D983151983151983154 K983145983156Vent door will automatically open when unit an is on

Factory Installed Feature Code - D

H983161983140983154983151983150983145983139 V983137983148983158983141983155Water and steam valves are available or use with theHWK03 (water) and HVK03 (steam) heat kits

W983145983154983141983148983141983155983155 RF (R983137983140983145983151 F983154983141983153983157983141983150983139983161) C983151983150983156983154983151983148983155All DigiSmart PTACs come actory-ready to be con-trolledvia wireless RF devices 24 Ghz 802 154 protocol assuresrobust communications and response

W983137983148983148 S983148983141983141983158983141 E983160983156983141983150983155983145983151983150 A983140983137983152983156983141983154 K983145983156983155Room-side extension kits to increase the depth o theexisting sleeve to allow or an industry-standard PTAC tobe installed

C983157983154983156983137983145983150 B983137983142983142983148983141 K983145983156The color matched polymer curtain baffles help toprevent curtains rom alling into the discharge airstream and causing recirculation reducing efficienciesand shortening compressor lie

PDK3A 230208V ndash R-22

PDK4A 265V ndash R-22

PDK3E 230208V ndash R-410A

PDK4E 265V ndash R-410A

VS2WNCA 2-way24VNCSteam VS2WNOA 2-way24VNOSteam VW2WNCA 2-way24VNCEnd Switch

VW2WNOA 2-way24VNOEnd Switch VW3WNC2B 3-way24VNCNOEnd Switch

Poptop Actuator

DS01EThermostat 2-way2 Communications

DD01EOccupancy SensorEMS Activation2

DT01GAntenna RouterFactory InstalledFeature Code - R

GT01GGeneric RadioAntenna Router3

DD01F Door Switch EMS Activation2

DP01G Web-enabled Platorm Server

DL01GWeb-enabled PlatormServer Link BAC-NET capable

DR01G Mesh Repeater1

DL01G-SERIAL

Serial Repeater1

1 Consult Amana Sales representative priorto purchase

2 Requires DT01G or use3 Requires DS01E or use

SECM1001A 15 Extension or 12frac12 Climate Master Sleeve (10 Pack)

SEZA0501A 25 Extension or 11frac12 Zone Air Sleeve (5 pack)

PTCB10B 10 Pack or R-22 units

PTCB10E 10 Pack or R-410A units

8182019 mc-dptac

httpslidepdfcomreaderfullmc-dptac 1620

16 wwwamana-ptaccom

Unit with Accessory Wall Sleeve and Sub-base Accessory

3

11

6- 18 9- 91624 -5 16

40

42

Location of external drain holes on bottom flange of Wall Sleeve

3 Clearance

to side walls

Air Flow

Air Flow

Air Flow

Air Discharge Grille ControlDoor

T983151983152 V983145983141983159

F983154983151983150983156 V98314598314198315958 LCDI CORD SET mdash 230V208V UNIT

58 CORD SET 230V208V UNIT

18 CORD SET 2 65V UNIT

3-14

MIN

2

MAX

2-58

42

16-116

RI GHTLEFT

1 and frac34 Concentric knock-outs back ampbottom o sub-base (electrical only)

R983145983143983144983156 V983145983141983159

2frac34

4

11⅜

983225983219 frasl ₁₆

983225983219 frasl ₁₆ 1⅜

16983225 frasl ₁₆

1⅜Arch Grille

⅞Stamped Grille

14⅛Wall Sleeve

21frac12

7⅜

Optional

Sub-base

HingedControlDoor

15deg

40deg

Air discharge grille is reversible to provideeither 15deg or 40deg discharge angle

frac12 ODCopperDrain Tube

8182019 mc-dptac

httpslidepdfcomreaderfullmc-dptac 1720

17Specifications and Accessories Catalog

Framing or Accessory Wall Sleeve (WS9XX)F983137983155983156983141983150983145983150983143 W983137983148983148 S983148983141983141983158983141When installed in an opening the Wall Sleeve must behorizontally level (side-to-side) and pitched frac14 bubble to the outside

(NOTE To ensure unitrsquos maximum efficiency DO NOT over- or under-pitch)

I983150983155983156983137983148983148983137983156983145983151983150 N9831519831569831419831551 I Sub-base (PTSBE) is installed allow minimum

3frac14 height clearance and maximum 5 heightclearance between wall sleeve and loor allowminimum 2frac34 protrusion rom a inished wallSee Note 4 if using hydronic units

2 Drain Kit (DK900D) shipped separately Can bemounted either right side lef side or bottom osleeve I mounted to bottom o sleeve allow2 height clearance rom loor to bottom o sleeve

3 For UL approval 265V units must use Amanareg brandSub-base (PTSBE) or Amanareg brand Hard WireKit (PSHW04A) Overcurrent protection on 265V unitsmust be by cartridge-style time delay uses whichare included and factory-installed on the Amanareg brand 265V chassis

4 I Hydronic Kit (HWK03 or HVK03) is installedWall Sleeve must extend exactly 3 into the roomrom the inished interior wall I using the Amana reg brand Sub-base (PTSBE) only the minimum3frac14 height clearance between wall sleeve and loor

is permissible Unit must also be operated with aremote-mounted thermostat

5 I Duct Kit (MDK) is installed allow a minimum o2⅜ into the room rom the inished interior wall

MountingHoles(Drilled byInstaller)

PlasticAnchor

Screws

ExpansionAnchor Bolt

Toggle Bolt

Wood Screw

AlternativeFastening Method(Field Supplied)

Wall Sleeve must extend a minimum o frac14 beyond outside wall to allow orproper caulking

FINISHED FLOOR

4 2 1 4

16 14

MIN

MAIN STUD

JACK STUDS

HEADER - 4 x 4 OR

DOUBLE 2x 4 ON EDGE

SUB-FLOOR

CRIPPLE

JACK STUD

ADJUST FRAMING TO

SECURE THIS DIMENSION

Wall sleeve opening height should be squared withwall sleeve opening width

H = 16frac14

W = 42frac14

8182019 mc-dptac

httpslidepdfcomreaderfullmc-dptac 1820

Notes

8182019 mc-dptac

httpslidepdfcomreaderfullmc-dptac 1920

Our continuing commitment to quality products may mean a change in speciications without noticecopy 2015 Goodman Company LP Amana is a registered trademark o Maytag Corporation or its related

companies and is used under license to Goodman Company LP Houston TX USA All rights reserved

Quiet two-an motor system

Energy-eicient perormance

DigiSmartreg wireless controls on select models

Wise DecisionItrsquos an Amanareg brand

8182019 mc-dptac

httpslidepdfcomreaderfullmc-dptac 2020

Our continuing commitment to quality products may mean a change in speciications without notice copy 2015 Goodman Company LPAmana is a registered trademark o Maytag Corporation or its related companies and is used under license to Goodman Company L P

wwwamana-ptaccom

Call your Amana brand PTAC sales representative at 800-647-2982 or complete details

Beore purchasing this appliance read important inormation about its estimated annual energy

consumption yearly operating cost or energy efficiency rating that is available rom your retailer

A legacy o comortThe impeccable reputation oan American original

Amana heating and cooling systems are a part of the

enduring legacy of one of Americarsquos most recognized

and respected brands Originating eight decades ago in

Amana Iowa the brand is synonymous with long-last-

ing premium-quality products mdash from home appliances

to heating and air conditioning equipment Chances

are you and generations beore you have enjoyed the

dependable performance and longevity the Amana

brand continues to deliver

MC-DPTAC 07-15Supersedes 06-15

Page 2: mc-dptac

8182019 mc-dptac

httpslidepdfcomreaderfullmc-dptac 220

DIGISMARTreg

A Combination of Energy Management and PTAC Performance

Amanareg brand DigiSmartreg brings together our best PTAC with our best energy management sofware that now integrates

with optional property management and ront desk management sofware Reduce PTAC energy consumption up to

35 OR MORE through the power o the in-unit energy management system programmable temperature set-back and

temperature limiting combined Our Maintenance Notification System can alert when there is a potential maintenance

issue with the PTAC

Amana brand DigiSmart SolutionI n -R o o m Self - I n s t al lable W ireles s Peripherals

The DigiSmart Wireless Remote

Thermostat can be mounted on the

wall anywhere in the guest room It is

Battery powered and with its own wire-

less ability to communicate with the

PTAC to maintain room temperature

Best of all there are no wires to run The PTAC and thermostat

connect at the press of a button and work in-sync to display

accurate temperature

The DigiSmart Occupancy Sensor

and Door Switch Combo Device

completes the in-room equipmentThis inrared sensor can determine

whether the room is occupied or

empty and when empty signal the PTAC to adjust the tem-

perature to save energy based on programmable set-backs

The DigiSmart Wireless Antenna

installs inside the PTAC with a snap-in

connector like a telephone jack In-

stalling the antenna allows the PTAC

to communicate wirelessly with other

devices in the room and to the DigiSmart network

60000+ rooms have had wireless installations

since 2005

Total wireless devices deployed to date 425000+

The Amana brand DigiSmart PTAC with antenna combined

with the self-installable wireless thermostat and occupancy

sensor give the property owner complete control over the

equipment settings and can reduce PTAC energy usage up

to 35 OR MORE

Site-Level mdash Central Wireless Controller

Site-wide PTAC Coniguration

Site-wide PTAC Diagnostics

Front-Desk System Interace

Email Reporting

Internet Accessible Web User Interace Enterprise

DigiSmart

Controller

These savings represent estimated savings over time and were generated using generalassumptions including energy loads local weather averages and use o occupancy controlsActual savings will vary according to actual use habits room square ootage and how the

unit is installed and maintained

8182019 mc-dptac

httpslidepdfcomreaderfullmc-dptac 320

3

Talk to your Amana brand dealer about opportunities to optimize the efficiency

of your new unit Before purchasing this appliance read important information

about its estimated annual energy consumption yearly operating cost or energy

efficiency rating that is available rom your dealer

wwwamana-ptaccom

wwwamana-ptaccom

Site 1 Site 2 Site 3

Internet

DigiSmartController

DigiSmartController

DigiSmartController

Maintenance Staff

Owner

Front Desk Staff General Managers

E n t e r p

r i s e o r

S i g n a l

S i g n a l

Data Warehouse Site Managment

P l a t f o r m

A c c e s s

E nt e r p r i s e o r P l at f o r m A c c e s s

Web-Based Monitoring ndashAmanareg brand DigiSmartreg ControllerAll PTACs in a building can be managed

through a single interace on a PC

Features Include

Full unit details or every PTAC visible rom the ront

desk or home oice

Automatic emails or PTAC maintenance

Ability to change all settings on the unit

Enhanced diagnostics

Monitors up to 170 PTACs WIRELESSLY with

one controller

Expand the network with additional controllers

ndash System Veriication ndash Site Statistics

ndash Global Setbacks ndash Email Reporting

ndash EMS Coniguration ndash Unit Health

ndash Site Statistics ndash Unit Code Alerts

Unrented Set-Points

By integrating with your propertyrsquos Front Desk System

the PTACs will adjust to specific set-points when no longer

identiied as rented in the system

Temp Limiting

Each PTAC can be configured with a heating and cooling

temperature set-point limit

Set-backs

Once a room is declared unoccupied by the occupancy

sensor the PTAC progresses through three different tem-

perature set-backs configured as three degree and time

pairs (An example coniguration is listed below)

1 2deg 30 mins ndash Setback the temp 2 degrees

ater 30 minutes

2 4deg 1 hr ndash Setback the temp 2 more degrees

ater 30 more minutes

3 8deg 3 hrs ndash Setback the temp 4 more degrees

ater 2 more hours

Enterprise ndash Multiple Wireless Controllers

Central Monitoring and Control o Multiple Properties

Data Warehousing

Virtual Metering

Savings Analysis

Load Shedding

Email Reporting

8182019 mc-dptac

httpslidepdfcomreaderfullmc-dptac 420

4 wwwamana-ptaccom

Standard Features Energy Efficiencies With EERs up to 120 and COPs

up to 34 our unitrsquos high eiciencies may qualiy

you or many o the rebates oered by electrical

power companies

Quiet Operation Our PTAC has been redesigned to be

the quietest PTAC wersquove ever built The unitrsquos state-

o-the-art design and construction provide a quiet

environment allowing guests to enjoy peaceul

sleep-illed nights

ndash Two an motors (indooroutdoor)

ndash Indoor tangential an or quiet operation

ndash STC o 28

Assembled in the USA for 35 years assembled at our

plant in Fayetteville TN using Goodman resources

including engineering production and testing

Increased Dehumidification Capacity Maintain lower

humidity levels in rooms while cooling them without

the need or expensive add-ons As a result guests eel

more comortable at higher temperatures thus

reducing cooling costs

Seven-Button Touch Pad Provides complete control

to guests or in-room comort while maintaining

energy e iciency

Five-Year Limited Warranty Enjoy one o the most

comprehensive warranties in the industry First Year

parts amp labor Second through ith years parts

amp labor on certain sealed system components

second through ith years on certain unctional

parts only For complete warranty details visit

wwwamana-ptaccom

100 Run Tested All units are 100 run tested atour plant in Fayetteville TN including leak checks

during manuacturing and again prior to shipment

at the warehouse

7⅝ Unit Front Depth Enhance valuable room

space with our slim unit ront which has a sleek

7⅝ depth one o the shallowest silhouettes in

the industry today In addition to inhibit guest-

tampering the ront can be secured to the chassis

with a hidden screw

Easy Pull-Out Filters Our ilters are washable and

easy to maintain

Filter Dryer for Sealed System Refrigerant Standard

in all units to protect the compressor and lengthen the

lie o the unit by removing moisture and preventing

acid ormation

Condensate Dispersion System Our condensate

dispersion system removes condensate rom indoor

cooling operation by throwing water directly on to

the outdoor coil or rapid evaporation and increased

cooling eiciencies The slinger ring on the new

enhanced an draws water up and into the an blades

This water is then atomized and evaporated into the

atmosphere through the condenser Increased surace

area rom the coil allows more water to be evaporatedon the sides o the coils and helps to minimize

condensate run-o

Front Desk Control Each unit comes equipped with

the DigiSmarttrade control and energ y management

sotware Using the DigiSmarttrade sotware and optional

RF Antenna all units can be wirelessly connected

to a central hub or enhanced energy savings and

diagnostics Amana brand PTACs also have a low-

voltage interace capability with a ield-supplied

ront-desk ONOFF switch (See inside ront cover)

8182019 mc-dptac

httpslidepdfcomreaderfullmc-dptac 520

5Specifications and Accessories Catalog

Room Freeze Protection When the unit senses

temperatures o 40degF or below the unit activates

the an motor and either the electric resistance

heater or the hydronic heater

Easy-to-use Controls No complex controls to conuse

your guests and create phone calls or your manager

Controls are easy to read understand and activate

Our new 7-button control panel provides guests with

complete control o the unit or their in-room comort

while maintaining overall energ y e iciency

Easy to Service with On-Board LED Diagnostics

The main components are easily serviced and there

is no guessing to determine the problem with our

easy-to-read diagnostics

Stonewood Room Front Our Stonewood room ront

strikes the balance between attractive st yling and

practical design Distinctive contours and a modern

appearance enhance the character o even the most

luxurious room while the sleek 7⅝ depth maximizes

usable space or your guests

Remote Thermostat Control When the DigiSmarttradewireless remote thermostat (DS01E sold separately) is

set up both the remote thermostat and unit control

panel continue to control the unit providing lexibility

and home-like system control Installation requires no

more than pressing two buttons No need to run wires

or make electrical connections

Extended Heat Pump Heating Heat pump models

will operate in the heating mode down to as low as

24degF outdoor ambient temperature

Zero Floor Clearance The unit can be installed lush

to a inished loor i desired (Some accessories do

not have zero clearance)

30-Second Fan-Off Delay The an continues to run

30 seconds ater the compressor has stopped in either

cooling or heat pump mode and ater electric heat has

been turned o This improves eiciency by dispersing

the conditioned air on the coils into the room

Compressor Lock-In This eature helps prolong the lie

o the compressor by preventing short-cycling When

the compressor is switched rom O to On because

room temperature has risen or allen below the

speciied limit it will remain on or at least 4 minutes

I the temperature set-point is changed during this4 minutes the lock-in eature is overridden

Automatic Emergency Heat No more ldquomy unit is not

heatingrdquo complaints during the middle o the night

Heat pump units will automatically switch over to

electric resistance heat i the heat pump compressor

system ails or i the heating load is greater than the

unit capacity

Constant Fan Mode Take advantage o each unitrsquos

dual options mdash select continuous an operation or

cycle the an ON and OFF with the thermostatOur 7-button design allows guests to select an

perormance while allowing the owner to have the

unit revert to the desired program o continuous

an or cycle with conditioning

Hidden Ventilation Control The ventilation control

lever is hidden rom the occupants view to allow you

to manage ventilation requirements

High-Pressure Switch Protects the unit rom high

pressure and damage to the unit helping to ensure

long unit lie

8182019 mc-dptac

httpslidepdfcomreaderfullmc-dptac 620

6 wwwamana-ptaccom

Nomenclature

123 45 6 7 89 1415

Basic Model Type Engineering

PTC Standard Cooler PTAC Major amp Minor Revisions

PTH Standard Heat Pump PTHP

DRY Dehumid Cooler PTAC Features Code

PMC DigiAIR Cooler PTAC A Standard Model

PMH DigiAIR Heat Pump PTAC C Corrosion Protection (Seacoast)

D Power Door

Nominal Cooling Capacity F Fuse Holder (230208 Only)

07 7000 BTUh 60 Hz L Lighting Control

09 9000 BTUh 60 Hz H Hydronic Heat-Capable

10 10000 BTUh 50 Hz P Condensate Pump (PTH Only)

12 12000 BTUh 50 or 60 Hz Q Quiet STC 31 Chassis

15 15000 BTUh 60 Hz R RF Antenna

17 17000 BTUh 60 Hz V Power Vent

X placeholder

Rated Voltage W Hard-Wired (PTQC)

2 115V 60 Hz 1 Phase

3 230208V 60 Hz 1 Phase Heater Size

4 265V 60 Hz 1 Phase 00 No Electric Heat 35 35 kW (230208V)

5 240220V 50 Hz 1 Phase Export 15 15 kW 37 kW (265V)

25 25 kW 50 50 kW

Design Series

G R-410A Use up to 4 as needed in alphabetical order Examples

PTC12350AXXX PTC07335CRXX

PTC12350CXXX PTC07325CQRW

AXXX AA

10111213

PTC 07 3 G 35

Power Cord Configuration

Power Receptacle Configuration

NEMA6-15R 250V

receptacle used on

230208V units

NEMA6-20R 250V

receptacle used on

230208V units

NEMA6-30R 250V

receptacle used on

230208V units

NEMA7-20R 277V receptacle

used on 265V units

NEMA7-30R 277V receptacle

used on 265V units

G

W

20 amp

G W

30 amp

15 amp 20 amp 30 amp

277V Rating Power Cord Plugs

NEMA 7 Configuration

250V Rating Power Cord Plugs with LCDI Device

NEMA 6 Configuration

Power Cord Plugs

All units come with factor-installed power cords

All units less than 250 volts come with LCDI device

8182019 mc-dptac

httpslidepdfcomreaderfullmc-dptac 720

7Specifications and Accessories Catalog

Product Speciications PTC Models mdash CoolingElectric Heat230208 Volts

Model 983094 983096 983097PTC

073GXXXPTC

093GXXXPTC

123GXXXPTC

153GXXXPTC

173GXXX

Voltage 983219 230 208 230 208 230 208 230 208 230 208Capacity (BTUh) 7700 7700 9000 9000 12000 11700 15000 14700 16400 16200Amps 983225⁰ 35 35 41 41 56 56 70 70 84Watts 983225⁰ 658 658 796 783 1114 1085 1500 1470 1740 1720EER 117 117 113 115 104 105 100 100 94

Unit without Electric Heater

Min Circuit Amps 983090 983092 983089983088 42 49 68 85 102

CFM (CoolWet Coil)High 290 290 290 340 340Low 264 264 264 314 314

CFM (Dry Coil)

High 310 310 310 360 360

Low 282 282 282 332 332Ventilated Air CFM (Fan Only) 65 65 65 65 65Dehumidification (PintsHr) 17 22 36 44 48Net Weight (lbs) 98 102 102 113 113Ship Weight (lbs) 113 117 119 130 130

265277 Volts

Model 983089 983094 983096PTC

074GXXXPTC

094GXXXPTC

124GXXXPTC

154GXXX

Voltage 983225 983219 265 265 265 265Capacity (BTUh) 7700 9000 12000 14800Amps 983225⁰ 30 36 48 60Watts 983225⁰ 658 796 1154 1480EER 117 113 104 100

Unit without Electric Heater

Min Circuit Amps 983090 983092983089983088 36 44 59 74

CFM (CoolWet Coil)High 290 290 290 340Low 264 264 264 314

CFM (Dry Coil)High 310 310 310 360Low 282 282 282 332

Ventilated Air CFM (Fan Only) 65 65 65 65Dehumidification (PintsHr) 17 22 36 44Net Weight (lbs) 98 102 102 113Ship Weight (lbs) 113 117 119 130

Actual vent CFM perormance will vary due to application and installation conditions

N983151983156983141983155983225 All 265-volt models must use an Amanareg brand sub-base (PTSB4E) or an Amanareg brand hard-wire kit PTPWHWK4 and

disconnect switch PSHW04A

983218 Minimum Circuit Ampacity (MCA) ratings conorm to the National Electric Code however local codes should apply

983219 Minimum voltage on 230208-volt models is 197 volts maximum is 253 volts Minimum voltage on 265-volt models is 239 volts

maximum is 292 volts⁴ Overcurrent protection or all units without electric heaters is 15 amps Overcurrent protection on 265-volt models must be

cartridge-style time-delay uses (included and actory-installed on all Amana reg brand 265-volt chassis) See heater perormance

⁵ Heating capacity and efficiency based on unit operation without condensate pump unit automatically switches to electricheat at approximately 24degF outdoor ambient

⁶ Speciy two-digit heater kW size to complete model number

⁷ R-410A rerigerant used in all systems

⁸ All units meet or exceed ASHRAE 901 standards

⁹ All units less than 250 volts have a Leak Current Detector Interrupter (LCDI) power cord and meet UL 484 standards

983225⁰ Reer to electric heat perormance data or total MCA and recommended overcurrent protection Amps and Watts notationreers to compressor only

8182019 mc-dptac

httpslidepdfcomreaderfullmc-dptac 820

8 wwwamana-ptaccom

Product Speciications PTH Models mdash CoolingHeat PumpElectric HeatM983151983140983141983148 983089 983094 983096 983097

PTH073GAXXX

PTH093GAXXX

PTH123GAXXX

PTH153GAXXX

PTH074GAXXX

PTH094GAXXX

PTH124GAXXX

PTH154GAXXX

Voltage 983225 983219 230 208 230 208 230 208 230 208 265 265 265 265

Capacity (BTUh) 7600 7600 9000 900012000 12000

14700 14700

7600 9100 12000 14600

Amps 983225⁰ 39 39 42 42 58 58 70 70 31 37 50 61

Watts 983225⁰ 650 633 750 750 1090 1090 1515 1515 650 758 1091 1505

EER 117 120 120120 110110 97 97 117 120 110 97

U983150983145983156 983159983145983156983144983151983157983156 E983148983141983139983156983154983145983139 H983141983137983156983141983154

Min Circuit Amps 983090 983092983089983088 47 51 71 85 38 45 61 74

CFM (CoolWet Coil) High 340 330 340 390 340 330 340 390Low 245 245 245 340 245 245 245 340

CFM (Dry Coil)High 370 360 370 410 370 360 370 410

Low 270 270 270 370 270 270 270 370

Ventilated Air CFM (Fan Only) 65 65 65 65 65 65 65 65

Dehumidiication (PintsHr) 17 22 36 44 17 22 36 44

Net Weight (lbs) 108 112 115 126 108 112 115 125

Ship Weight (lbs) 123 127 132 143 123 127 132 142

Actual vent CFM perormance will vary due to application and installation conditions

N983151983156983141983155983225 All 265-volt models must use an Amanareg brand sub-base (PTSB4E) or an Amanareg brand hard-wire kit (PTPWHWK4)983218 Minimum Circuit Ampacity (MCA) ratings conorm to the National Electric Code however local codes should apply

Minimum voltage on 230208-volt models is 197 volts maximum is 253 volts983219 Minimum voltage on 265-volt models is 239 volts maximum is 292 volts⁴ Overcurrent protection or all units without electric heaters is 15 amps Overcurrent protection on 265-volt models must be

cartridge-style time-delay uses (included and actory-installed on all Amanareg brand 265-volt chassis)⁵ Heating capacity and efficiency based on unit operation without condensate pump unit automatically switches to electric

heat at approximately 24degF outdoor ambient⁶ Speciy two-digit heater kW size to complete model number⁷ R-410A rerigerant used in all systems⁸ All units meet or exceed ASHRAE 901 standards⁹ All units less than 250 volts have a Leak Current Detector Interrupter (LCDI) power cord and meet UL 484 standards983225⁰ Reer to electric heat perormance data or total MCA and recommended overcurrent protection Amps and Watts notation

reers to compressor only

8182019 mc-dptac

httpslidepdfcomreaderfullmc-dptac 920

9Specifications and Accessories Catalog

Actual vent CFM perormance will vary due to application and installation conditions

N983151983156983141983155983225 Minimum Circuit Ampacity (MCA) ratings conorm to the National Electric Code however local codes should apply983090 Minimum voltage on 115-volt models is 109 volts maximum is 127 volts983091 Overcurrent protection or all units without electric heaters is 15 amps⁴ R-410A rerigerant used in all systems

⁵ All units meet or exceed ASHRAE 901 standards⁶ All units less than 250 volts have a Leak Current Detector Interrupter (LCDI) power cord and meet UL 484 standards

M983151983140983141983148 983093 983094PTC

072GXXXPTC

092GXXX

Voltage 983090 115 115

Capacity (BTUh) 7000 9000

Amps 69 83

Watts 585 795

EER 119 113

Min Circuit Amps 983089 983091 83 101

CFM (CoolWet Coil)High 290 290

Low 264 264

CFM (Dry Coil)High 310 310

Low 282 282

Ventilated Air (Fan Only) 65 65

Dehumidiication (PintsHr) 17 23

Net Weight (lbs) 98 102

Ship Weight (lbs) 113 117

Product Speciications PTC 115-Volt Models mdashCoolingHydronic Heat or No-Heat Models

8182019 mc-dptac

httpslidepdfcomreaderfullmc-dptac 1020

10 wwwamana-ptaccom

Product Speciications PTH Models mdash Reverse-Cycle Heating PerormanceH983141983137983156983145983150983143

C983137983152983137983139983145983156983161983225PTH073G

AXXXPTH093G

AXXXPTH123G

AXXXPTH153G

AXXXPTH074G

AXXXPTH094G

AXXXPTH124G

AXXXPTH154G

AXXX

Voltage 983225 983219 230 208 230 208 230 208 230 208 265 265 265 265

BTUh ⁵ 6800 6800 8300 8100 11500 11300 13800 13600 6800 8300 11400 13700

Amps 983225⁰ 39 39 42 42 58 58 70 70 31 37 50 61

Watts 983225⁰ 585 585 715 700 1085 1035 1350 1330 585 715 1080 1340

COP ⁵ 34 34 34 34 31 32 30 30 34 34 31 30

CFM (Dry) 370 360 370 410 370 360 370 410

COP = Coefficiency o Perormance per AHRI Test Procedures units are rated or capacities and efficiencies

N983151983156983141983155

983225 All 265-volt models must use an Amanareg brand sub-base (PTSB4E) or an Amanareg brand hard-wire kit (PTPWHWK4)983218 Minimum branch circuit ampacity ratings conorm to the National Electric Code however local codes should apply983219 Minimum voltage on 230208-volt models is 197 volts maximum is 253 volts

Minimum voltage on 265-volt models is 239 volts maximum is 292 volts⁴ Overcurrent protection or all units without electric heaters is 15 amps Overcurrent protection on 265-volt models must

be cartridge-style time-delay uses (included and actory-installed on all Amanareg brand 265-volt chassis)⁵ Heating capacity and efficiency based on unit operation without condensate pump unit automatically switches to electric

heat at approximately 24degF outdoor ambient⁶ Speciy two-digit heater kW size to complete model number⁷ R-410A rerigerant used in all systems⁸ All units meet or exceed ASHRAE 901 standards⁹ All units less than 250 volts have a Leak Current Detector Interrupter (LCDI) power cord and meet UL 484 standards983225⁰ Reer to electric heat perormance data or total MCA and recommended overcurrent protection

Amps and Watts notation reers to compressor only

Product Speciications PTC PTH Models mdash Electric Heat Perormance(Primary Heating or PTC Models Auxiliary Heating or PTH Models See below or Power Cord Coniguration)

V983151983148983156983137983143983141E983148983141983139983156983154983145983139H983141983137983156983141983154

S983145983162983141 (983147W)

N983151 983151983142S983156983137983143983141983155

N983151983149983145983150983137983148 H983141983137983156983145983150983143 (BTU983144)T983151983156983137983148

W983137983156983156983155983094T983151983156983137983148 A983149983152983155

M983145983150 C983145983154983139983157983145983156 A983149983152983137983139983145983156983161983218

MOP983092(983137983149983152983155)

P983151983159983141983154C983151983154983140

10486269830911048624V 104862610486241048632V 104862610486301048629V

230208V 15 13 1 5100 4200 - - 1570 1295 68 62 85 15 6-15 P

230208V 25 21 1 8500 6800 - - 2570 2115 112 101 141 15 6-15 P

230208V 35 30 1 12000 9900 - - 3570 2935 155 141 195 20 6-20 P

230208V 50 41 1 17100 14000 - - 5070 4160 221 200 276 30 6-30 P

265V 15 1 - - - - 5100 1570 59 74 15 7-20P

265V 25 1 - - - - 8500 2570 97 122 15 7-20 P

265V 37 1 - - - - 12600 3770 142 179 20 7-20 P265V 5 1 - - - - 17100 5070 192 239 25 7-30 P

N983151983156983141983155983225 All 265-volt models must use an Amanareg brand sub-base (PTSB4E) or an Amanareg brand hard-wire kit (PTPWHWK4)983218 Minimum branch circuit ampacity ratings conorm to the National Electric Code however local codes should apply983219 Minimum voltage on 230208-volt models is 197 volts maximum is 253 volts Minimum voltage on 265-volt models is 239 volts maximum is 292 volts⁴ Overcurrent protection or all units without electric heaters is 15 amps Overcurrent protection on 265-volt models must be cartridge-style

time-delay uses (included and actory-installed on all Amanareg brand 265-volt chassis)⁵ Heating capacity and efficiency based on unit operation without condensate pump unit automatically switches to electric heat at

approximately 24degF outdoor ambient⁶ Total watts or 15000 BTUh models subtract 20 watts or PT070912⁷ Speciy two-digit heater kW size to complete model number⁸ R-410A rerigerant used in all systems⁹ All units meet or exceed ASHRAE 901 standards983225⁰ All units less than 250 volts have a Leak Current Detector Interrupter (LCDI) power cord and meet UL 484 standards

8182019 mc-dptac

httpslidepdfcomreaderfullmc-dptac 1120

11Specifications and Accessories Catalog

AccessoriesW983137983148983148 S983148983141983141983158983141983155All our wall sleeves have industry standard dimensionso 42 wide x 16⅟ ₁₆ high The WS900E SC and INTERNAL14⅛ depth is the industry standard Sleeves maybe shipped separately to allow or installationduring construction

C983151983150983140983141983150983155983137983156983141 D983154983137983145983150 K983145983156Attaches to the wall sleeve base pan or controlledinternal or external disposal o condensate

L983151983159983085V983151983148983156983137983143983141 W983145983154983141 H983137983154983150983141983155983155 K983145983156 (983150983151983156 983155983144983151983159983150)For quick connections o the remote or wiredthermostats wired EMS or ront desk with jumpers andconnectors

R983141983149983151983156983141 E983155983139983157983156983139983144983141983151983150 K983145983156 (983150983151983156 983155983144983151983159983150)Optional kit or use with units controlled via a wiredremote thermostat Covers control touch-pad or wiredthermostat installations

Each ldquoBrdquo kit contains 80 wires and wire nutsenough to attach a thermostat and oneadditional accessory to 10 PTAC units Wirescome in assorted colors or easy attachmentEach ldquoArdquo kit contains 10 Escutcheon plates only

O983157983156983140983151983151983154 G983154983145983148983148983141983155Available in stamped-aluminum or architecturallylouvered or application with an Amana brand WS900Ewall sleeve

AGK Extruded aluminum architectural grille availablewith anodized aluminum inish or a baked-on paintinish or durability Choose rom 3 stock colors or acustom color to blend with your buildingrsquos exteriorcolor scheme Colors include

CB (Clear Anodized) DB (Dark BrownBronze)TB (Stonewood Beige) WB (White)SB (SpecialCustom Colors)

PGK One-piece injection molded grille using a polymerblend o engineered thermoplastic high-impactstrength material with chemical resistance andan exterior UV protective coating

Choose from 3 stock colorsDB (Dark BrownBronze) TB (Stonewood Beige)

WB (White)

S983156983137983150983140983137983154983140983085D983141983152983156983144 S983148983141983141983158983141983155

WS900E-GS Heavy Sound Isolation Insulation Sleeve

WS900E Standard PTAC sleeve

WS900SC Seacoast triple protected

WS900D-INTERNAL

Internal drain only or window-wallinstallations (DK900D sold separately)

E983160983156983154983137 D983141983141983152 S983148983141983141983158983141983155 in several depths orthicker wall installations or special roomconigurations

WS9XXD1 16 to 24 in 1 increments

WS928D1 Extra deep 28

WS930D1 Extra deep 30

WS936D1 Extra deep 36

WS9XXD1-Interna

Extra deep Internal drain onlyor window-wall installations(DK900D sold separately) 1 4

⅛ 4 2

1 6

1

1 6

S983156983137983150983140983137983154983140 O983157983156983140983151983151983154 G983154983145983148983148983141

SGK01B Single Pack

SGK01TB Stonewood Beige

A983154983139983144983145983156983141983139983156983157983154983137983148 O983157983156983140983151983151983154 G983154983145983148983148983141

AGK01CB Anodized Aluminum

AGK01DB Dark BronzeBrown

AGK01TB Stonewood Beige

AGK01WB Amana White

AGK01SB Custom Colors

PGK01DB Dark BronzeBrown

PGK01TB Stonewood Beige

PGK01WB Amana White

AGKor

PGK

SGK

DK900DCondensate Drain Kit(use with WS900E)

DK9001DCondensate Drain Kit(use with WS900B)

DK900D

PWHK01C Wire Harness Kit

REK10BRemote Escutcheon Kit(10-pack)

REK10A Remote Escutcheon Plates

8182019 mc-dptac

httpslidepdfcomreaderfullmc-dptac 1220

12 wwwamana-ptaccom

Accessories (cont)S983157983138983085983138983137983155983141 K983145983156The ully skirted sub-base conceals wiring whileproviding strong support i needed Plug-in receptacleand ield-wiring access speeds installation Electricalaccessories such as use holders circuit breakers anddisconnect switches meet NEC requirements

L983141983158983141983148983145983150983143 L983141983143983155Gives wall sleeve ront support and helps to level theunit or installation

H983137983154983140983085983159983145983154983141 K983145983156983155Used to permanently wire to the chassis when astandard sub-base and power cord are not utilized

F983137983139983156983151983154983161 I983150983155983156983137983148983148983141983140 Feature Code - W

P983151983159983141983154 D983145983155983139983151983150983150983141983139983156 S983159983145983156983139983144The PSHWA power disconnect switch can be usedor 265-volt or 230208-volt physical disconnectwhere required by local codes The switch is ratedat 30-amp capacity The switch is or use with andAmanareg brand standard sub-bases or PTPWHWK4Hard Wire Kit

F983157983155983141 H983151983148983140983141983154 K983145983156Cartridge-style uses can be installed in the useholder or use in the sub-base or chassis Available in15 20 and 30 amp (included on 265-volt unit)

C983145983154983139983157983145983156 B983154983141983137983147983141983154 K983145983156 (983090983091983088983090983088983096V 983151983150983148983161)The circuit breaker kit available in 15 20 or 30 ampcan be used with Amana brand sub-bases It givesovercurrent protection and its location allows you toturn the unit on or off without tools

PTSB215E 115V15A

PTSB320E 230208V 1520A

PTSB330E 230208V 30A

PTSB420E 265V 1520A

PTSB430E 265V 25A

PTSB000E Non-electrical

LL2B Leveling legs or WS9 sleeves

PTPWHWK4 Armored Cable ndash all voltages

PTQC3A Quick Connect ndash 230208V

PTQC4A Quick Connect ndash 265 amp 115 V

PSHW03A 230208V

PSHW04A 265V

FHK315E 230208V 15A

FHK315E 230208V 15A (R-410A)

FHK320C 230208V 20A

FHK320E 230208V 20A (R-410A)

FHK330C 230208V 30A

FHK330E 230208V 30A (R-410A)

CBK15C 15 amp Circuit Breaker Kit

CBK20C 20 amp Circuit Breaker Kit

CBK30C 30 amp Circuit Breaker Kit

8182019 mc-dptac

httpslidepdfcomreaderfullmc-dptac 1320

13Specifications and Accessories Catalog

Accessories (cont)

P983151983159983141983154 V983141983150983156 K983145983156Installation o Power Vent increases CFM up toapproximately 95 Vent door will automatically closewhen unit an is off

F983137983139983156983151983154983161 I983150983155983156983137983148983148983141983140 Feature Code - VR-410A models must have these kits installed atthe actory

C983151983150983140983141983150983155983141983154 B983137983142983142983148983141 K983145983156For use on non-baffled grilles These delectors directthe air in toward the center and away rom the inlet toprevent recirculation o the hot condenser air

S983157983138983085983138983137983155983141 E983160983156983141983150983155983145983151983150 C983151983158983141983154 K983145983156Converts older 30-amp sub-bases to allow or installationo the larger 30-amp LCDI power cord and plugs

S983141983139983157983154983145983156983161 K983141983161 L983151983139983147983155In conjunction with the tamper-resistant ront theinstallation o Amanareg brand security key locks preventstampering o the controls used to set temperature heatingand cooling unctions UL approved or institutionaluse only

C983151983150983140983141983150983155983137983156983141 R983141983149983151983158983137983148 P983157983149983152Can be ield-installed Assists in removing condensatedeveloped by heat pump operation and transers it to

indoor coil to dissipate into room while adding humidityto the room

F983137983139983156983151983154983161 I983150983155983156983137983148983148983141983140 Feature Code - P

PVK3A 230208V ndash R-22

PVK4A 265V ndash R-22

D983157983139983156 E983160983156983141983150983155983145983151983150 K983145983156Extends air distribution to an adjoining room Consistsof a main duct for the room of origin and an extensionduct to reach the adjoining room and terminal ductPTDK01A allows for the ldquoBrdquo series unit to work with theldquoArdquo series duct kits

MDK02B Main Duct ndash R-22

MDK01E Main Duct ndash R-410A

EDK02B 42 Extension Duct

TRANSITION BAFFLES

Main Duct Kit

TDK02B Terminal Duct

PTDK01A Transition Duct Only ndash R-22

PTDK01E Transition Duct Only ndash R-410A

Extension Duct Kit

Terminal Duct Kit

DGK1B Condenser Baffle Kit

SBEC10A 10 Pack

Basepan

Condenser

Condenser Baffles

KL03B Security Key Lock (R-22)

KL03E Security Key Lock (R-410A)

CDP302 230208V ndash R-22

CDP402 265V ndash R-22

CDP303E 230208V ndash R-410A

8182019 mc-dptac

httpslidepdfcomreaderfullmc-dptac 1420

14 wwwamana-ptaccom

Accessories (cont)

HWK03B Hydronic Water Kit ndash R-22

HVK03B Hydronic Steam Kit ndash R-22

HWK03E Hydronic Water Kit ndash R-410A

HVK03E Hydronic Steam Kit ndash R-410A

ThermostatsThe ollowing thermostats offer remote control Any thermostat other than those listed must be submitted to Goodman Company LPor approval prior to use

H983161983140983154983151983150983145983139 H983141983137983156 K983145983156Add-on kits it all units allowing the addition o hydronicwater or hydronic steam heat to cooling and heating unitsThe kits eature lef- or right-hand piping Unit retainscomplete service access with a kit installed Unit must beconnected to and operated by a wall thermostat

Hydronic Heat Kit Top View

Hydronic Heat Kit Right View

M983151983140983141983148 H983141983137983156 S983156983137983143983141983155 C983151983151983148 S983156983137983143983141983155 F983137983150 S983152983141983141983140 983151983142 W983145983154983141983155R983141983153983157983145983154983141983140

T983141983149983152L983145983149983145983156983145983150983143

B983137983139983147983148983145983156 D983145983155983152983148983137983161 T983161983152983141S983144983137983152983141 983078

O983154983145983141983150983156983137983156983145983151983150C983151983150983150983141983139983156983145983151983150

2246002 1 1 1 5 No Yes Digital Manual RectHoriz Wired

2246003 2 2 2 7 Yes Yes Digital Manual RectHoriz Wired

2246007 2 2 1 7 Yes Yes Digital Auto-Change RectHoriz Wired

2246008 2 2 1 7 Yes Yes Digital Programmable RectHoriz Wired

DS01E 2 2 2 0 Yes Yes Digital Manual RectHoriz Wireless

Battery powered but has optional hard wire capability Requires DT01G Antennae or operation

Hydronic Heat KitSide View

8182019 mc-dptac

httpslidepdfcomreaderfullmc-dptac 1520

15Specifications and Accessories Catalog

Accessories (cont)P983151983159983141983154 D983151983151983154 K983145983156Vent door will automatically open when unit an is on

Factory Installed Feature Code - D

H983161983140983154983151983150983145983139 V983137983148983158983141983155Water and steam valves are available or use with theHWK03 (water) and HVK03 (steam) heat kits

W983145983154983141983148983141983155983155 RF (R983137983140983145983151 F983154983141983153983157983141983150983139983161) C983151983150983156983154983151983148983155All DigiSmart PTACs come actory-ready to be con-trolledvia wireless RF devices 24 Ghz 802 154 protocol assuresrobust communications and response

W983137983148983148 S983148983141983141983158983141 E983160983156983141983150983155983145983151983150 A983140983137983152983156983141983154 K983145983156983155Room-side extension kits to increase the depth o theexisting sleeve to allow or an industry-standard PTAC tobe installed

C983157983154983156983137983145983150 B983137983142983142983148983141 K983145983156The color matched polymer curtain baffles help toprevent curtains rom alling into the discharge airstream and causing recirculation reducing efficienciesand shortening compressor lie

PDK3A 230208V ndash R-22

PDK4A 265V ndash R-22

PDK3E 230208V ndash R-410A

PDK4E 265V ndash R-410A

VS2WNCA 2-way24VNCSteam VS2WNOA 2-way24VNOSteam VW2WNCA 2-way24VNCEnd Switch

VW2WNOA 2-way24VNOEnd Switch VW3WNC2B 3-way24VNCNOEnd Switch

Poptop Actuator

DS01EThermostat 2-way2 Communications

DD01EOccupancy SensorEMS Activation2

DT01GAntenna RouterFactory InstalledFeature Code - R

GT01GGeneric RadioAntenna Router3

DD01F Door Switch EMS Activation2

DP01G Web-enabled Platorm Server

DL01GWeb-enabled PlatormServer Link BAC-NET capable

DR01G Mesh Repeater1

DL01G-SERIAL

Serial Repeater1

1 Consult Amana Sales representative priorto purchase

2 Requires DT01G or use3 Requires DS01E or use

SECM1001A 15 Extension or 12frac12 Climate Master Sleeve (10 Pack)

SEZA0501A 25 Extension or 11frac12 Zone Air Sleeve (5 pack)

PTCB10B 10 Pack or R-22 units

PTCB10E 10 Pack or R-410A units

8182019 mc-dptac

httpslidepdfcomreaderfullmc-dptac 1620

16 wwwamana-ptaccom

Unit with Accessory Wall Sleeve and Sub-base Accessory

3

11

6- 18 9- 91624 -5 16

40

42

Location of external drain holes on bottom flange of Wall Sleeve

3 Clearance

to side walls

Air Flow

Air Flow

Air Flow

Air Discharge Grille ControlDoor

T983151983152 V983145983141983159

F983154983151983150983156 V98314598314198315958 LCDI CORD SET mdash 230V208V UNIT

58 CORD SET 230V208V UNIT

18 CORD SET 2 65V UNIT

3-14

MIN

2

MAX

2-58

42

16-116

RI GHTLEFT

1 and frac34 Concentric knock-outs back ampbottom o sub-base (electrical only)

R983145983143983144983156 V983145983141983159

2frac34

4

11⅜

983225983219 frasl ₁₆

983225983219 frasl ₁₆ 1⅜

16983225 frasl ₁₆

1⅜Arch Grille

⅞Stamped Grille

14⅛Wall Sleeve

21frac12

7⅜

Optional

Sub-base

HingedControlDoor

15deg

40deg

Air discharge grille is reversible to provideeither 15deg or 40deg discharge angle

frac12 ODCopperDrain Tube

8182019 mc-dptac

httpslidepdfcomreaderfullmc-dptac 1720

17Specifications and Accessories Catalog

Framing or Accessory Wall Sleeve (WS9XX)F983137983155983156983141983150983145983150983143 W983137983148983148 S983148983141983141983158983141When installed in an opening the Wall Sleeve must behorizontally level (side-to-side) and pitched frac14 bubble to the outside

(NOTE To ensure unitrsquos maximum efficiency DO NOT over- or under-pitch)

I983150983155983156983137983148983148983137983156983145983151983150 N9831519831569831419831551 I Sub-base (PTSBE) is installed allow minimum

3frac14 height clearance and maximum 5 heightclearance between wall sleeve and loor allowminimum 2frac34 protrusion rom a inished wallSee Note 4 if using hydronic units

2 Drain Kit (DK900D) shipped separately Can bemounted either right side lef side or bottom osleeve I mounted to bottom o sleeve allow2 height clearance rom loor to bottom o sleeve

3 For UL approval 265V units must use Amanareg brandSub-base (PTSBE) or Amanareg brand Hard WireKit (PSHW04A) Overcurrent protection on 265V unitsmust be by cartridge-style time delay uses whichare included and factory-installed on the Amanareg brand 265V chassis

4 I Hydronic Kit (HWK03 or HVK03) is installedWall Sleeve must extend exactly 3 into the roomrom the inished interior wall I using the Amana reg brand Sub-base (PTSBE) only the minimum3frac14 height clearance between wall sleeve and loor

is permissible Unit must also be operated with aremote-mounted thermostat

5 I Duct Kit (MDK) is installed allow a minimum o2⅜ into the room rom the inished interior wall

MountingHoles(Drilled byInstaller)

PlasticAnchor

Screws

ExpansionAnchor Bolt

Toggle Bolt

Wood Screw

AlternativeFastening Method(Field Supplied)

Wall Sleeve must extend a minimum o frac14 beyond outside wall to allow orproper caulking

FINISHED FLOOR

4 2 1 4

16 14

MIN

MAIN STUD

JACK STUDS

HEADER - 4 x 4 OR

DOUBLE 2x 4 ON EDGE

SUB-FLOOR

CRIPPLE

JACK STUD

ADJUST FRAMING TO

SECURE THIS DIMENSION

Wall sleeve opening height should be squared withwall sleeve opening width

H = 16frac14

W = 42frac14

8182019 mc-dptac

httpslidepdfcomreaderfullmc-dptac 1820

Notes

8182019 mc-dptac

httpslidepdfcomreaderfullmc-dptac 1920

Our continuing commitment to quality products may mean a change in speciications without noticecopy 2015 Goodman Company LP Amana is a registered trademark o Maytag Corporation or its related

companies and is used under license to Goodman Company LP Houston TX USA All rights reserved

Quiet two-an motor system

Energy-eicient perormance

DigiSmartreg wireless controls on select models

Wise DecisionItrsquos an Amanareg brand

8182019 mc-dptac

httpslidepdfcomreaderfullmc-dptac 2020

Our continuing commitment to quality products may mean a change in speciications without notice copy 2015 Goodman Company LPAmana is a registered trademark o Maytag Corporation or its related companies and is used under license to Goodman Company L P

wwwamana-ptaccom

Call your Amana brand PTAC sales representative at 800-647-2982 or complete details

Beore purchasing this appliance read important inormation about its estimated annual energy

consumption yearly operating cost or energy efficiency rating that is available rom your retailer

A legacy o comortThe impeccable reputation oan American original

Amana heating and cooling systems are a part of the

enduring legacy of one of Americarsquos most recognized

and respected brands Originating eight decades ago in

Amana Iowa the brand is synonymous with long-last-

ing premium-quality products mdash from home appliances

to heating and air conditioning equipment Chances

are you and generations beore you have enjoyed the

dependable performance and longevity the Amana

brand continues to deliver

MC-DPTAC 07-15Supersedes 06-15

Page 3: mc-dptac

8182019 mc-dptac

httpslidepdfcomreaderfullmc-dptac 320

3

Talk to your Amana brand dealer about opportunities to optimize the efficiency

of your new unit Before purchasing this appliance read important information

about its estimated annual energy consumption yearly operating cost or energy

efficiency rating that is available rom your dealer

wwwamana-ptaccom

wwwamana-ptaccom

Site 1 Site 2 Site 3

Internet

DigiSmartController

DigiSmartController

DigiSmartController

Maintenance Staff

Owner

Front Desk Staff General Managers

E n t e r p

r i s e o r

S i g n a l

S i g n a l

Data Warehouse Site Managment

P l a t f o r m

A c c e s s

E nt e r p r i s e o r P l at f o r m A c c e s s

Web-Based Monitoring ndashAmanareg brand DigiSmartreg ControllerAll PTACs in a building can be managed

through a single interace on a PC

Features Include

Full unit details or every PTAC visible rom the ront

desk or home oice

Automatic emails or PTAC maintenance

Ability to change all settings on the unit

Enhanced diagnostics

Monitors up to 170 PTACs WIRELESSLY with

one controller

Expand the network with additional controllers

ndash System Veriication ndash Site Statistics

ndash Global Setbacks ndash Email Reporting

ndash EMS Coniguration ndash Unit Health

ndash Site Statistics ndash Unit Code Alerts

Unrented Set-Points

By integrating with your propertyrsquos Front Desk System

the PTACs will adjust to specific set-points when no longer

identiied as rented in the system

Temp Limiting

Each PTAC can be configured with a heating and cooling

temperature set-point limit

Set-backs

Once a room is declared unoccupied by the occupancy

sensor the PTAC progresses through three different tem-

perature set-backs configured as three degree and time

pairs (An example coniguration is listed below)

1 2deg 30 mins ndash Setback the temp 2 degrees

ater 30 minutes

2 4deg 1 hr ndash Setback the temp 2 more degrees

ater 30 more minutes

3 8deg 3 hrs ndash Setback the temp 4 more degrees

ater 2 more hours

Enterprise ndash Multiple Wireless Controllers

Central Monitoring and Control o Multiple Properties

Data Warehousing

Virtual Metering

Savings Analysis

Load Shedding

Email Reporting

8182019 mc-dptac

httpslidepdfcomreaderfullmc-dptac 420

4 wwwamana-ptaccom

Standard Features Energy Efficiencies With EERs up to 120 and COPs

up to 34 our unitrsquos high eiciencies may qualiy

you or many o the rebates oered by electrical

power companies

Quiet Operation Our PTAC has been redesigned to be

the quietest PTAC wersquove ever built The unitrsquos state-

o-the-art design and construction provide a quiet

environment allowing guests to enjoy peaceul

sleep-illed nights

ndash Two an motors (indooroutdoor)

ndash Indoor tangential an or quiet operation

ndash STC o 28

Assembled in the USA for 35 years assembled at our

plant in Fayetteville TN using Goodman resources

including engineering production and testing

Increased Dehumidification Capacity Maintain lower

humidity levels in rooms while cooling them without

the need or expensive add-ons As a result guests eel

more comortable at higher temperatures thus

reducing cooling costs

Seven-Button Touch Pad Provides complete control

to guests or in-room comort while maintaining

energy e iciency

Five-Year Limited Warranty Enjoy one o the most

comprehensive warranties in the industry First Year

parts amp labor Second through ith years parts

amp labor on certain sealed system components

second through ith years on certain unctional

parts only For complete warranty details visit

wwwamana-ptaccom

100 Run Tested All units are 100 run tested atour plant in Fayetteville TN including leak checks

during manuacturing and again prior to shipment

at the warehouse

7⅝ Unit Front Depth Enhance valuable room

space with our slim unit ront which has a sleek

7⅝ depth one o the shallowest silhouettes in

the industry today In addition to inhibit guest-

tampering the ront can be secured to the chassis

with a hidden screw

Easy Pull-Out Filters Our ilters are washable and

easy to maintain

Filter Dryer for Sealed System Refrigerant Standard

in all units to protect the compressor and lengthen the

lie o the unit by removing moisture and preventing

acid ormation

Condensate Dispersion System Our condensate

dispersion system removes condensate rom indoor

cooling operation by throwing water directly on to

the outdoor coil or rapid evaporation and increased

cooling eiciencies The slinger ring on the new

enhanced an draws water up and into the an blades

This water is then atomized and evaporated into the

atmosphere through the condenser Increased surace

area rom the coil allows more water to be evaporatedon the sides o the coils and helps to minimize

condensate run-o

Front Desk Control Each unit comes equipped with

the DigiSmarttrade control and energ y management

sotware Using the DigiSmarttrade sotware and optional

RF Antenna all units can be wirelessly connected

to a central hub or enhanced energy savings and

diagnostics Amana brand PTACs also have a low-

voltage interace capability with a ield-supplied

ront-desk ONOFF switch (See inside ront cover)

8182019 mc-dptac

httpslidepdfcomreaderfullmc-dptac 520

5Specifications and Accessories Catalog

Room Freeze Protection When the unit senses

temperatures o 40degF or below the unit activates

the an motor and either the electric resistance

heater or the hydronic heater

Easy-to-use Controls No complex controls to conuse

your guests and create phone calls or your manager

Controls are easy to read understand and activate

Our new 7-button control panel provides guests with

complete control o the unit or their in-room comort

while maintaining overall energ y e iciency

Easy to Service with On-Board LED Diagnostics

The main components are easily serviced and there

is no guessing to determine the problem with our

easy-to-read diagnostics

Stonewood Room Front Our Stonewood room ront

strikes the balance between attractive st yling and

practical design Distinctive contours and a modern

appearance enhance the character o even the most

luxurious room while the sleek 7⅝ depth maximizes

usable space or your guests

Remote Thermostat Control When the DigiSmarttradewireless remote thermostat (DS01E sold separately) is

set up both the remote thermostat and unit control

panel continue to control the unit providing lexibility

and home-like system control Installation requires no

more than pressing two buttons No need to run wires

or make electrical connections

Extended Heat Pump Heating Heat pump models

will operate in the heating mode down to as low as

24degF outdoor ambient temperature

Zero Floor Clearance The unit can be installed lush

to a inished loor i desired (Some accessories do

not have zero clearance)

30-Second Fan-Off Delay The an continues to run

30 seconds ater the compressor has stopped in either

cooling or heat pump mode and ater electric heat has

been turned o This improves eiciency by dispersing

the conditioned air on the coils into the room

Compressor Lock-In This eature helps prolong the lie

o the compressor by preventing short-cycling When

the compressor is switched rom O to On because

room temperature has risen or allen below the

speciied limit it will remain on or at least 4 minutes

I the temperature set-point is changed during this4 minutes the lock-in eature is overridden

Automatic Emergency Heat No more ldquomy unit is not

heatingrdquo complaints during the middle o the night

Heat pump units will automatically switch over to

electric resistance heat i the heat pump compressor

system ails or i the heating load is greater than the

unit capacity

Constant Fan Mode Take advantage o each unitrsquos

dual options mdash select continuous an operation or

cycle the an ON and OFF with the thermostatOur 7-button design allows guests to select an

perormance while allowing the owner to have the

unit revert to the desired program o continuous

an or cycle with conditioning

Hidden Ventilation Control The ventilation control

lever is hidden rom the occupants view to allow you

to manage ventilation requirements

High-Pressure Switch Protects the unit rom high

pressure and damage to the unit helping to ensure

long unit lie

8182019 mc-dptac

httpslidepdfcomreaderfullmc-dptac 620

6 wwwamana-ptaccom

Nomenclature

123 45 6 7 89 1415

Basic Model Type Engineering

PTC Standard Cooler PTAC Major amp Minor Revisions

PTH Standard Heat Pump PTHP

DRY Dehumid Cooler PTAC Features Code

PMC DigiAIR Cooler PTAC A Standard Model

PMH DigiAIR Heat Pump PTAC C Corrosion Protection (Seacoast)

D Power Door

Nominal Cooling Capacity F Fuse Holder (230208 Only)

07 7000 BTUh 60 Hz L Lighting Control

09 9000 BTUh 60 Hz H Hydronic Heat-Capable

10 10000 BTUh 50 Hz P Condensate Pump (PTH Only)

12 12000 BTUh 50 or 60 Hz Q Quiet STC 31 Chassis

15 15000 BTUh 60 Hz R RF Antenna

17 17000 BTUh 60 Hz V Power Vent

X placeholder

Rated Voltage W Hard-Wired (PTQC)

2 115V 60 Hz 1 Phase

3 230208V 60 Hz 1 Phase Heater Size

4 265V 60 Hz 1 Phase 00 No Electric Heat 35 35 kW (230208V)

5 240220V 50 Hz 1 Phase Export 15 15 kW 37 kW (265V)

25 25 kW 50 50 kW

Design Series

G R-410A Use up to 4 as needed in alphabetical order Examples

PTC12350AXXX PTC07335CRXX

PTC12350CXXX PTC07325CQRW

AXXX AA

10111213

PTC 07 3 G 35

Power Cord Configuration

Power Receptacle Configuration

NEMA6-15R 250V

receptacle used on

230208V units

NEMA6-20R 250V

receptacle used on

230208V units

NEMA6-30R 250V

receptacle used on

230208V units

NEMA7-20R 277V receptacle

used on 265V units

NEMA7-30R 277V receptacle

used on 265V units

G

W

20 amp

G W

30 amp

15 amp 20 amp 30 amp

277V Rating Power Cord Plugs

NEMA 7 Configuration

250V Rating Power Cord Plugs with LCDI Device

NEMA 6 Configuration

Power Cord Plugs

All units come with factor-installed power cords

All units less than 250 volts come with LCDI device

8182019 mc-dptac

httpslidepdfcomreaderfullmc-dptac 720

7Specifications and Accessories Catalog

Product Speciications PTC Models mdash CoolingElectric Heat230208 Volts

Model 983094 983096 983097PTC

073GXXXPTC

093GXXXPTC

123GXXXPTC

153GXXXPTC

173GXXX

Voltage 983219 230 208 230 208 230 208 230 208 230 208Capacity (BTUh) 7700 7700 9000 9000 12000 11700 15000 14700 16400 16200Amps 983225⁰ 35 35 41 41 56 56 70 70 84Watts 983225⁰ 658 658 796 783 1114 1085 1500 1470 1740 1720EER 117 117 113 115 104 105 100 100 94

Unit without Electric Heater

Min Circuit Amps 983090 983092 983089983088 42 49 68 85 102

CFM (CoolWet Coil)High 290 290 290 340 340Low 264 264 264 314 314

CFM (Dry Coil)

High 310 310 310 360 360

Low 282 282 282 332 332Ventilated Air CFM (Fan Only) 65 65 65 65 65Dehumidification (PintsHr) 17 22 36 44 48Net Weight (lbs) 98 102 102 113 113Ship Weight (lbs) 113 117 119 130 130

265277 Volts

Model 983089 983094 983096PTC

074GXXXPTC

094GXXXPTC

124GXXXPTC

154GXXX

Voltage 983225 983219 265 265 265 265Capacity (BTUh) 7700 9000 12000 14800Amps 983225⁰ 30 36 48 60Watts 983225⁰ 658 796 1154 1480EER 117 113 104 100

Unit without Electric Heater

Min Circuit Amps 983090 983092983089983088 36 44 59 74

CFM (CoolWet Coil)High 290 290 290 340Low 264 264 264 314

CFM (Dry Coil)High 310 310 310 360Low 282 282 282 332

Ventilated Air CFM (Fan Only) 65 65 65 65Dehumidification (PintsHr) 17 22 36 44Net Weight (lbs) 98 102 102 113Ship Weight (lbs) 113 117 119 130

Actual vent CFM perormance will vary due to application and installation conditions

N983151983156983141983155983225 All 265-volt models must use an Amanareg brand sub-base (PTSB4E) or an Amanareg brand hard-wire kit PTPWHWK4 and

disconnect switch PSHW04A

983218 Minimum Circuit Ampacity (MCA) ratings conorm to the National Electric Code however local codes should apply

983219 Minimum voltage on 230208-volt models is 197 volts maximum is 253 volts Minimum voltage on 265-volt models is 239 volts

maximum is 292 volts⁴ Overcurrent protection or all units without electric heaters is 15 amps Overcurrent protection on 265-volt models must be

cartridge-style time-delay uses (included and actory-installed on all Amana reg brand 265-volt chassis) See heater perormance

⁵ Heating capacity and efficiency based on unit operation without condensate pump unit automatically switches to electricheat at approximately 24degF outdoor ambient

⁶ Speciy two-digit heater kW size to complete model number

⁷ R-410A rerigerant used in all systems

⁸ All units meet or exceed ASHRAE 901 standards

⁹ All units less than 250 volts have a Leak Current Detector Interrupter (LCDI) power cord and meet UL 484 standards

983225⁰ Reer to electric heat perormance data or total MCA and recommended overcurrent protection Amps and Watts notationreers to compressor only

8182019 mc-dptac

httpslidepdfcomreaderfullmc-dptac 820

8 wwwamana-ptaccom

Product Speciications PTH Models mdash CoolingHeat PumpElectric HeatM983151983140983141983148 983089 983094 983096 983097

PTH073GAXXX

PTH093GAXXX

PTH123GAXXX

PTH153GAXXX

PTH074GAXXX

PTH094GAXXX

PTH124GAXXX

PTH154GAXXX

Voltage 983225 983219 230 208 230 208 230 208 230 208 265 265 265 265

Capacity (BTUh) 7600 7600 9000 900012000 12000

14700 14700

7600 9100 12000 14600

Amps 983225⁰ 39 39 42 42 58 58 70 70 31 37 50 61

Watts 983225⁰ 650 633 750 750 1090 1090 1515 1515 650 758 1091 1505

EER 117 120 120120 110110 97 97 117 120 110 97

U983150983145983156 983159983145983156983144983151983157983156 E983148983141983139983156983154983145983139 H983141983137983156983141983154

Min Circuit Amps 983090 983092983089983088 47 51 71 85 38 45 61 74

CFM (CoolWet Coil) High 340 330 340 390 340 330 340 390Low 245 245 245 340 245 245 245 340

CFM (Dry Coil)High 370 360 370 410 370 360 370 410

Low 270 270 270 370 270 270 270 370

Ventilated Air CFM (Fan Only) 65 65 65 65 65 65 65 65

Dehumidiication (PintsHr) 17 22 36 44 17 22 36 44

Net Weight (lbs) 108 112 115 126 108 112 115 125

Ship Weight (lbs) 123 127 132 143 123 127 132 142

Actual vent CFM perormance will vary due to application and installation conditions

N983151983156983141983155983225 All 265-volt models must use an Amanareg brand sub-base (PTSB4E) or an Amanareg brand hard-wire kit (PTPWHWK4)983218 Minimum Circuit Ampacity (MCA) ratings conorm to the National Electric Code however local codes should apply

Minimum voltage on 230208-volt models is 197 volts maximum is 253 volts983219 Minimum voltage on 265-volt models is 239 volts maximum is 292 volts⁴ Overcurrent protection or all units without electric heaters is 15 amps Overcurrent protection on 265-volt models must be

cartridge-style time-delay uses (included and actory-installed on all Amanareg brand 265-volt chassis)⁵ Heating capacity and efficiency based on unit operation without condensate pump unit automatically switches to electric

heat at approximately 24degF outdoor ambient⁶ Speciy two-digit heater kW size to complete model number⁷ R-410A rerigerant used in all systems⁸ All units meet or exceed ASHRAE 901 standards⁹ All units less than 250 volts have a Leak Current Detector Interrupter (LCDI) power cord and meet UL 484 standards983225⁰ Reer to electric heat perormance data or total MCA and recommended overcurrent protection Amps and Watts notation

reers to compressor only

8182019 mc-dptac

httpslidepdfcomreaderfullmc-dptac 920

9Specifications and Accessories Catalog

Actual vent CFM perormance will vary due to application and installation conditions

N983151983156983141983155983225 Minimum Circuit Ampacity (MCA) ratings conorm to the National Electric Code however local codes should apply983090 Minimum voltage on 115-volt models is 109 volts maximum is 127 volts983091 Overcurrent protection or all units without electric heaters is 15 amps⁴ R-410A rerigerant used in all systems

⁵ All units meet or exceed ASHRAE 901 standards⁶ All units less than 250 volts have a Leak Current Detector Interrupter (LCDI) power cord and meet UL 484 standards

M983151983140983141983148 983093 983094PTC

072GXXXPTC

092GXXX

Voltage 983090 115 115

Capacity (BTUh) 7000 9000

Amps 69 83

Watts 585 795

EER 119 113

Min Circuit Amps 983089 983091 83 101

CFM (CoolWet Coil)High 290 290

Low 264 264

CFM (Dry Coil)High 310 310

Low 282 282

Ventilated Air (Fan Only) 65 65

Dehumidiication (PintsHr) 17 23

Net Weight (lbs) 98 102

Ship Weight (lbs) 113 117

Product Speciications PTC 115-Volt Models mdashCoolingHydronic Heat or No-Heat Models

8182019 mc-dptac

httpslidepdfcomreaderfullmc-dptac 1020

10 wwwamana-ptaccom

Product Speciications PTH Models mdash Reverse-Cycle Heating PerormanceH983141983137983156983145983150983143

C983137983152983137983139983145983156983161983225PTH073G

AXXXPTH093G

AXXXPTH123G

AXXXPTH153G

AXXXPTH074G

AXXXPTH094G

AXXXPTH124G

AXXXPTH154G

AXXX

Voltage 983225 983219 230 208 230 208 230 208 230 208 265 265 265 265

BTUh ⁵ 6800 6800 8300 8100 11500 11300 13800 13600 6800 8300 11400 13700

Amps 983225⁰ 39 39 42 42 58 58 70 70 31 37 50 61

Watts 983225⁰ 585 585 715 700 1085 1035 1350 1330 585 715 1080 1340

COP ⁵ 34 34 34 34 31 32 30 30 34 34 31 30

CFM (Dry) 370 360 370 410 370 360 370 410

COP = Coefficiency o Perormance per AHRI Test Procedures units are rated or capacities and efficiencies

N983151983156983141983155

983225 All 265-volt models must use an Amanareg brand sub-base (PTSB4E) or an Amanareg brand hard-wire kit (PTPWHWK4)983218 Minimum branch circuit ampacity ratings conorm to the National Electric Code however local codes should apply983219 Minimum voltage on 230208-volt models is 197 volts maximum is 253 volts

Minimum voltage on 265-volt models is 239 volts maximum is 292 volts⁴ Overcurrent protection or all units without electric heaters is 15 amps Overcurrent protection on 265-volt models must

be cartridge-style time-delay uses (included and actory-installed on all Amanareg brand 265-volt chassis)⁵ Heating capacity and efficiency based on unit operation without condensate pump unit automatically switches to electric

heat at approximately 24degF outdoor ambient⁶ Speciy two-digit heater kW size to complete model number⁷ R-410A rerigerant used in all systems⁸ All units meet or exceed ASHRAE 901 standards⁹ All units less than 250 volts have a Leak Current Detector Interrupter (LCDI) power cord and meet UL 484 standards983225⁰ Reer to electric heat perormance data or total MCA and recommended overcurrent protection

Amps and Watts notation reers to compressor only

Product Speciications PTC PTH Models mdash Electric Heat Perormance(Primary Heating or PTC Models Auxiliary Heating or PTH Models See below or Power Cord Coniguration)

V983151983148983156983137983143983141E983148983141983139983156983154983145983139H983141983137983156983141983154

S983145983162983141 (983147W)

N983151 983151983142S983156983137983143983141983155

N983151983149983145983150983137983148 H983141983137983156983145983150983143 (BTU983144)T983151983156983137983148

W983137983156983156983155983094T983151983156983137983148 A983149983152983155

M983145983150 C983145983154983139983157983145983156 A983149983152983137983139983145983156983161983218

MOP983092(983137983149983152983155)

P983151983159983141983154C983151983154983140

10486269830911048624V 104862610486241048632V 104862610486301048629V

230208V 15 13 1 5100 4200 - - 1570 1295 68 62 85 15 6-15 P

230208V 25 21 1 8500 6800 - - 2570 2115 112 101 141 15 6-15 P

230208V 35 30 1 12000 9900 - - 3570 2935 155 141 195 20 6-20 P

230208V 50 41 1 17100 14000 - - 5070 4160 221 200 276 30 6-30 P

265V 15 1 - - - - 5100 1570 59 74 15 7-20P

265V 25 1 - - - - 8500 2570 97 122 15 7-20 P

265V 37 1 - - - - 12600 3770 142 179 20 7-20 P265V 5 1 - - - - 17100 5070 192 239 25 7-30 P

N983151983156983141983155983225 All 265-volt models must use an Amanareg brand sub-base (PTSB4E) or an Amanareg brand hard-wire kit (PTPWHWK4)983218 Minimum branch circuit ampacity ratings conorm to the National Electric Code however local codes should apply983219 Minimum voltage on 230208-volt models is 197 volts maximum is 253 volts Minimum voltage on 265-volt models is 239 volts maximum is 292 volts⁴ Overcurrent protection or all units without electric heaters is 15 amps Overcurrent protection on 265-volt models must be cartridge-style

time-delay uses (included and actory-installed on all Amanareg brand 265-volt chassis)⁵ Heating capacity and efficiency based on unit operation without condensate pump unit automatically switches to electric heat at

approximately 24degF outdoor ambient⁶ Total watts or 15000 BTUh models subtract 20 watts or PT070912⁷ Speciy two-digit heater kW size to complete model number⁸ R-410A rerigerant used in all systems⁹ All units meet or exceed ASHRAE 901 standards983225⁰ All units less than 250 volts have a Leak Current Detector Interrupter (LCDI) power cord and meet UL 484 standards

8182019 mc-dptac

httpslidepdfcomreaderfullmc-dptac 1120

11Specifications and Accessories Catalog

AccessoriesW983137983148983148 S983148983141983141983158983141983155All our wall sleeves have industry standard dimensionso 42 wide x 16⅟ ₁₆ high The WS900E SC and INTERNAL14⅛ depth is the industry standard Sleeves maybe shipped separately to allow or installationduring construction

C983151983150983140983141983150983155983137983156983141 D983154983137983145983150 K983145983156Attaches to the wall sleeve base pan or controlledinternal or external disposal o condensate

L983151983159983085V983151983148983156983137983143983141 W983145983154983141 H983137983154983150983141983155983155 K983145983156 (983150983151983156 983155983144983151983159983150)For quick connections o the remote or wiredthermostats wired EMS or ront desk with jumpers andconnectors

R983141983149983151983156983141 E983155983139983157983156983139983144983141983151983150 K983145983156 (983150983151983156 983155983144983151983159983150)Optional kit or use with units controlled via a wiredremote thermostat Covers control touch-pad or wiredthermostat installations

Each ldquoBrdquo kit contains 80 wires and wire nutsenough to attach a thermostat and oneadditional accessory to 10 PTAC units Wirescome in assorted colors or easy attachmentEach ldquoArdquo kit contains 10 Escutcheon plates only

O983157983156983140983151983151983154 G983154983145983148983148983141983155Available in stamped-aluminum or architecturallylouvered or application with an Amana brand WS900Ewall sleeve

AGK Extruded aluminum architectural grille availablewith anodized aluminum inish or a baked-on paintinish or durability Choose rom 3 stock colors or acustom color to blend with your buildingrsquos exteriorcolor scheme Colors include

CB (Clear Anodized) DB (Dark BrownBronze)TB (Stonewood Beige) WB (White)SB (SpecialCustom Colors)

PGK One-piece injection molded grille using a polymerblend o engineered thermoplastic high-impactstrength material with chemical resistance andan exterior UV protective coating

Choose from 3 stock colorsDB (Dark BrownBronze) TB (Stonewood Beige)

WB (White)

S983156983137983150983140983137983154983140983085D983141983152983156983144 S983148983141983141983158983141983155

WS900E-GS Heavy Sound Isolation Insulation Sleeve

WS900E Standard PTAC sleeve

WS900SC Seacoast triple protected

WS900D-INTERNAL

Internal drain only or window-wallinstallations (DK900D sold separately)

E983160983156983154983137 D983141983141983152 S983148983141983141983158983141983155 in several depths orthicker wall installations or special roomconigurations

WS9XXD1 16 to 24 in 1 increments

WS928D1 Extra deep 28

WS930D1 Extra deep 30

WS936D1 Extra deep 36

WS9XXD1-Interna

Extra deep Internal drain onlyor window-wall installations(DK900D sold separately) 1 4

⅛ 4 2

1 6

1

1 6

S983156983137983150983140983137983154983140 O983157983156983140983151983151983154 G983154983145983148983148983141

SGK01B Single Pack

SGK01TB Stonewood Beige

A983154983139983144983145983156983141983139983156983157983154983137983148 O983157983156983140983151983151983154 G983154983145983148983148983141

AGK01CB Anodized Aluminum

AGK01DB Dark BronzeBrown

AGK01TB Stonewood Beige

AGK01WB Amana White

AGK01SB Custom Colors

PGK01DB Dark BronzeBrown

PGK01TB Stonewood Beige

PGK01WB Amana White

AGKor

PGK

SGK

DK900DCondensate Drain Kit(use with WS900E)

DK9001DCondensate Drain Kit(use with WS900B)

DK900D

PWHK01C Wire Harness Kit

REK10BRemote Escutcheon Kit(10-pack)

REK10A Remote Escutcheon Plates

8182019 mc-dptac

httpslidepdfcomreaderfullmc-dptac 1220

12 wwwamana-ptaccom

Accessories (cont)S983157983138983085983138983137983155983141 K983145983156The ully skirted sub-base conceals wiring whileproviding strong support i needed Plug-in receptacleand ield-wiring access speeds installation Electricalaccessories such as use holders circuit breakers anddisconnect switches meet NEC requirements

L983141983158983141983148983145983150983143 L983141983143983155Gives wall sleeve ront support and helps to level theunit or installation

H983137983154983140983085983159983145983154983141 K983145983156983155Used to permanently wire to the chassis when astandard sub-base and power cord are not utilized

F983137983139983156983151983154983161 I983150983155983156983137983148983148983141983140 Feature Code - W

P983151983159983141983154 D983145983155983139983151983150983150983141983139983156 S983159983145983156983139983144The PSHWA power disconnect switch can be usedor 265-volt or 230208-volt physical disconnectwhere required by local codes The switch is ratedat 30-amp capacity The switch is or use with andAmanareg brand standard sub-bases or PTPWHWK4Hard Wire Kit

F983157983155983141 H983151983148983140983141983154 K983145983156Cartridge-style uses can be installed in the useholder or use in the sub-base or chassis Available in15 20 and 30 amp (included on 265-volt unit)

C983145983154983139983157983145983156 B983154983141983137983147983141983154 K983145983156 (983090983091983088983090983088983096V 983151983150983148983161)The circuit breaker kit available in 15 20 or 30 ampcan be used with Amana brand sub-bases It givesovercurrent protection and its location allows you toturn the unit on or off without tools

PTSB215E 115V15A

PTSB320E 230208V 1520A

PTSB330E 230208V 30A

PTSB420E 265V 1520A

PTSB430E 265V 25A

PTSB000E Non-electrical

LL2B Leveling legs or WS9 sleeves

PTPWHWK4 Armored Cable ndash all voltages

PTQC3A Quick Connect ndash 230208V

PTQC4A Quick Connect ndash 265 amp 115 V

PSHW03A 230208V

PSHW04A 265V

FHK315E 230208V 15A

FHK315E 230208V 15A (R-410A)

FHK320C 230208V 20A

FHK320E 230208V 20A (R-410A)

FHK330C 230208V 30A

FHK330E 230208V 30A (R-410A)

CBK15C 15 amp Circuit Breaker Kit

CBK20C 20 amp Circuit Breaker Kit

CBK30C 30 amp Circuit Breaker Kit

8182019 mc-dptac

httpslidepdfcomreaderfullmc-dptac 1320

13Specifications and Accessories Catalog

Accessories (cont)

P983151983159983141983154 V983141983150983156 K983145983156Installation o Power Vent increases CFM up toapproximately 95 Vent door will automatically closewhen unit an is off

F983137983139983156983151983154983161 I983150983155983156983137983148983148983141983140 Feature Code - VR-410A models must have these kits installed atthe actory

C983151983150983140983141983150983155983141983154 B983137983142983142983148983141 K983145983156For use on non-baffled grilles These delectors directthe air in toward the center and away rom the inlet toprevent recirculation o the hot condenser air

S983157983138983085983138983137983155983141 E983160983156983141983150983155983145983151983150 C983151983158983141983154 K983145983156Converts older 30-amp sub-bases to allow or installationo the larger 30-amp LCDI power cord and plugs

S983141983139983157983154983145983156983161 K983141983161 L983151983139983147983155In conjunction with the tamper-resistant ront theinstallation o Amanareg brand security key locks preventstampering o the controls used to set temperature heatingand cooling unctions UL approved or institutionaluse only

C983151983150983140983141983150983155983137983156983141 R983141983149983151983158983137983148 P983157983149983152Can be ield-installed Assists in removing condensatedeveloped by heat pump operation and transers it to

indoor coil to dissipate into room while adding humidityto the room

F983137983139983156983151983154983161 I983150983155983156983137983148983148983141983140 Feature Code - P

PVK3A 230208V ndash R-22

PVK4A 265V ndash R-22

D983157983139983156 E983160983156983141983150983155983145983151983150 K983145983156Extends air distribution to an adjoining room Consistsof a main duct for the room of origin and an extensionduct to reach the adjoining room and terminal ductPTDK01A allows for the ldquoBrdquo series unit to work with theldquoArdquo series duct kits

MDK02B Main Duct ndash R-22

MDK01E Main Duct ndash R-410A

EDK02B 42 Extension Duct

TRANSITION BAFFLES

Main Duct Kit

TDK02B Terminal Duct

PTDK01A Transition Duct Only ndash R-22

PTDK01E Transition Duct Only ndash R-410A

Extension Duct Kit

Terminal Duct Kit

DGK1B Condenser Baffle Kit

SBEC10A 10 Pack

Basepan

Condenser

Condenser Baffles

KL03B Security Key Lock (R-22)

KL03E Security Key Lock (R-410A)

CDP302 230208V ndash R-22

CDP402 265V ndash R-22

CDP303E 230208V ndash R-410A

8182019 mc-dptac

httpslidepdfcomreaderfullmc-dptac 1420

14 wwwamana-ptaccom

Accessories (cont)

HWK03B Hydronic Water Kit ndash R-22

HVK03B Hydronic Steam Kit ndash R-22

HWK03E Hydronic Water Kit ndash R-410A

HVK03E Hydronic Steam Kit ndash R-410A

ThermostatsThe ollowing thermostats offer remote control Any thermostat other than those listed must be submitted to Goodman Company LPor approval prior to use

H983161983140983154983151983150983145983139 H983141983137983156 K983145983156Add-on kits it all units allowing the addition o hydronicwater or hydronic steam heat to cooling and heating unitsThe kits eature lef- or right-hand piping Unit retainscomplete service access with a kit installed Unit must beconnected to and operated by a wall thermostat

Hydronic Heat Kit Top View

Hydronic Heat Kit Right View

M983151983140983141983148 H983141983137983156 S983156983137983143983141983155 C983151983151983148 S983156983137983143983141983155 F983137983150 S983152983141983141983140 983151983142 W983145983154983141983155R983141983153983157983145983154983141983140

T983141983149983152L983145983149983145983156983145983150983143

B983137983139983147983148983145983156 D983145983155983152983148983137983161 T983161983152983141S983144983137983152983141 983078

O983154983145983141983150983156983137983156983145983151983150C983151983150983150983141983139983156983145983151983150

2246002 1 1 1 5 No Yes Digital Manual RectHoriz Wired

2246003 2 2 2 7 Yes Yes Digital Manual RectHoriz Wired

2246007 2 2 1 7 Yes Yes Digital Auto-Change RectHoriz Wired

2246008 2 2 1 7 Yes Yes Digital Programmable RectHoriz Wired

DS01E 2 2 2 0 Yes Yes Digital Manual RectHoriz Wireless

Battery powered but has optional hard wire capability Requires DT01G Antennae or operation

Hydronic Heat KitSide View

8182019 mc-dptac

httpslidepdfcomreaderfullmc-dptac 1520

15Specifications and Accessories Catalog

Accessories (cont)P983151983159983141983154 D983151983151983154 K983145983156Vent door will automatically open when unit an is on

Factory Installed Feature Code - D

H983161983140983154983151983150983145983139 V983137983148983158983141983155Water and steam valves are available or use with theHWK03 (water) and HVK03 (steam) heat kits

W983145983154983141983148983141983155983155 RF (R983137983140983145983151 F983154983141983153983157983141983150983139983161) C983151983150983156983154983151983148983155All DigiSmart PTACs come actory-ready to be con-trolledvia wireless RF devices 24 Ghz 802 154 protocol assuresrobust communications and response

W983137983148983148 S983148983141983141983158983141 E983160983156983141983150983155983145983151983150 A983140983137983152983156983141983154 K983145983156983155Room-side extension kits to increase the depth o theexisting sleeve to allow or an industry-standard PTAC tobe installed

C983157983154983156983137983145983150 B983137983142983142983148983141 K983145983156The color matched polymer curtain baffles help toprevent curtains rom alling into the discharge airstream and causing recirculation reducing efficienciesand shortening compressor lie

PDK3A 230208V ndash R-22

PDK4A 265V ndash R-22

PDK3E 230208V ndash R-410A

PDK4E 265V ndash R-410A

VS2WNCA 2-way24VNCSteam VS2WNOA 2-way24VNOSteam VW2WNCA 2-way24VNCEnd Switch

VW2WNOA 2-way24VNOEnd Switch VW3WNC2B 3-way24VNCNOEnd Switch

Poptop Actuator

DS01EThermostat 2-way2 Communications

DD01EOccupancy SensorEMS Activation2

DT01GAntenna RouterFactory InstalledFeature Code - R

GT01GGeneric RadioAntenna Router3

DD01F Door Switch EMS Activation2

DP01G Web-enabled Platorm Server

DL01GWeb-enabled PlatormServer Link BAC-NET capable

DR01G Mesh Repeater1

DL01G-SERIAL

Serial Repeater1

1 Consult Amana Sales representative priorto purchase

2 Requires DT01G or use3 Requires DS01E or use

SECM1001A 15 Extension or 12frac12 Climate Master Sleeve (10 Pack)

SEZA0501A 25 Extension or 11frac12 Zone Air Sleeve (5 pack)

PTCB10B 10 Pack or R-22 units

PTCB10E 10 Pack or R-410A units

8182019 mc-dptac

httpslidepdfcomreaderfullmc-dptac 1620

16 wwwamana-ptaccom

Unit with Accessory Wall Sleeve and Sub-base Accessory

3

11

6- 18 9- 91624 -5 16

40

42

Location of external drain holes on bottom flange of Wall Sleeve

3 Clearance

to side walls

Air Flow

Air Flow

Air Flow

Air Discharge Grille ControlDoor

T983151983152 V983145983141983159

F983154983151983150983156 V98314598314198315958 LCDI CORD SET mdash 230V208V UNIT

58 CORD SET 230V208V UNIT

18 CORD SET 2 65V UNIT

3-14

MIN

2

MAX

2-58

42

16-116

RI GHTLEFT

1 and frac34 Concentric knock-outs back ampbottom o sub-base (electrical only)

R983145983143983144983156 V983145983141983159

2frac34

4

11⅜

983225983219 frasl ₁₆

983225983219 frasl ₁₆ 1⅜

16983225 frasl ₁₆

1⅜Arch Grille

⅞Stamped Grille

14⅛Wall Sleeve

21frac12

7⅜

Optional

Sub-base

HingedControlDoor

15deg

40deg

Air discharge grille is reversible to provideeither 15deg or 40deg discharge angle

frac12 ODCopperDrain Tube

8182019 mc-dptac

httpslidepdfcomreaderfullmc-dptac 1720

17Specifications and Accessories Catalog

Framing or Accessory Wall Sleeve (WS9XX)F983137983155983156983141983150983145983150983143 W983137983148983148 S983148983141983141983158983141When installed in an opening the Wall Sleeve must behorizontally level (side-to-side) and pitched frac14 bubble to the outside

(NOTE To ensure unitrsquos maximum efficiency DO NOT over- or under-pitch)

I983150983155983156983137983148983148983137983156983145983151983150 N9831519831569831419831551 I Sub-base (PTSBE) is installed allow minimum

3frac14 height clearance and maximum 5 heightclearance between wall sleeve and loor allowminimum 2frac34 protrusion rom a inished wallSee Note 4 if using hydronic units

2 Drain Kit (DK900D) shipped separately Can bemounted either right side lef side or bottom osleeve I mounted to bottom o sleeve allow2 height clearance rom loor to bottom o sleeve

3 For UL approval 265V units must use Amanareg brandSub-base (PTSBE) or Amanareg brand Hard WireKit (PSHW04A) Overcurrent protection on 265V unitsmust be by cartridge-style time delay uses whichare included and factory-installed on the Amanareg brand 265V chassis

4 I Hydronic Kit (HWK03 or HVK03) is installedWall Sleeve must extend exactly 3 into the roomrom the inished interior wall I using the Amana reg brand Sub-base (PTSBE) only the minimum3frac14 height clearance between wall sleeve and loor

is permissible Unit must also be operated with aremote-mounted thermostat

5 I Duct Kit (MDK) is installed allow a minimum o2⅜ into the room rom the inished interior wall

MountingHoles(Drilled byInstaller)

PlasticAnchor

Screws

ExpansionAnchor Bolt

Toggle Bolt

Wood Screw

AlternativeFastening Method(Field Supplied)

Wall Sleeve must extend a minimum o frac14 beyond outside wall to allow orproper caulking

FINISHED FLOOR

4 2 1 4

16 14

MIN

MAIN STUD

JACK STUDS

HEADER - 4 x 4 OR

DOUBLE 2x 4 ON EDGE

SUB-FLOOR

CRIPPLE

JACK STUD

ADJUST FRAMING TO

SECURE THIS DIMENSION

Wall sleeve opening height should be squared withwall sleeve opening width

H = 16frac14

W = 42frac14

8182019 mc-dptac

httpslidepdfcomreaderfullmc-dptac 1820

Notes

8182019 mc-dptac

httpslidepdfcomreaderfullmc-dptac 1920

Our continuing commitment to quality products may mean a change in speciications without noticecopy 2015 Goodman Company LP Amana is a registered trademark o Maytag Corporation or its related

companies and is used under license to Goodman Company LP Houston TX USA All rights reserved

Quiet two-an motor system

Energy-eicient perormance

DigiSmartreg wireless controls on select models

Wise DecisionItrsquos an Amanareg brand

8182019 mc-dptac

httpslidepdfcomreaderfullmc-dptac 2020

Our continuing commitment to quality products may mean a change in speciications without notice copy 2015 Goodman Company LPAmana is a registered trademark o Maytag Corporation or its related companies and is used under license to Goodman Company L P

wwwamana-ptaccom

Call your Amana brand PTAC sales representative at 800-647-2982 or complete details

Beore purchasing this appliance read important inormation about its estimated annual energy

consumption yearly operating cost or energy efficiency rating that is available rom your retailer

A legacy o comortThe impeccable reputation oan American original

Amana heating and cooling systems are a part of the

enduring legacy of one of Americarsquos most recognized

and respected brands Originating eight decades ago in

Amana Iowa the brand is synonymous with long-last-

ing premium-quality products mdash from home appliances

to heating and air conditioning equipment Chances

are you and generations beore you have enjoyed the

dependable performance and longevity the Amana

brand continues to deliver

MC-DPTAC 07-15Supersedes 06-15

Page 4: mc-dptac

8182019 mc-dptac

httpslidepdfcomreaderfullmc-dptac 420

4 wwwamana-ptaccom

Standard Features Energy Efficiencies With EERs up to 120 and COPs

up to 34 our unitrsquos high eiciencies may qualiy

you or many o the rebates oered by electrical

power companies

Quiet Operation Our PTAC has been redesigned to be

the quietest PTAC wersquove ever built The unitrsquos state-

o-the-art design and construction provide a quiet

environment allowing guests to enjoy peaceul

sleep-illed nights

ndash Two an motors (indooroutdoor)

ndash Indoor tangential an or quiet operation

ndash STC o 28

Assembled in the USA for 35 years assembled at our

plant in Fayetteville TN using Goodman resources

including engineering production and testing

Increased Dehumidification Capacity Maintain lower

humidity levels in rooms while cooling them without

the need or expensive add-ons As a result guests eel

more comortable at higher temperatures thus

reducing cooling costs

Seven-Button Touch Pad Provides complete control

to guests or in-room comort while maintaining

energy e iciency

Five-Year Limited Warranty Enjoy one o the most

comprehensive warranties in the industry First Year

parts amp labor Second through ith years parts

amp labor on certain sealed system components

second through ith years on certain unctional

parts only For complete warranty details visit

wwwamana-ptaccom

100 Run Tested All units are 100 run tested atour plant in Fayetteville TN including leak checks

during manuacturing and again prior to shipment

at the warehouse

7⅝ Unit Front Depth Enhance valuable room

space with our slim unit ront which has a sleek

7⅝ depth one o the shallowest silhouettes in

the industry today In addition to inhibit guest-

tampering the ront can be secured to the chassis

with a hidden screw

Easy Pull-Out Filters Our ilters are washable and

easy to maintain

Filter Dryer for Sealed System Refrigerant Standard

in all units to protect the compressor and lengthen the

lie o the unit by removing moisture and preventing

acid ormation

Condensate Dispersion System Our condensate

dispersion system removes condensate rom indoor

cooling operation by throwing water directly on to

the outdoor coil or rapid evaporation and increased

cooling eiciencies The slinger ring on the new

enhanced an draws water up and into the an blades

This water is then atomized and evaporated into the

atmosphere through the condenser Increased surace

area rom the coil allows more water to be evaporatedon the sides o the coils and helps to minimize

condensate run-o

Front Desk Control Each unit comes equipped with

the DigiSmarttrade control and energ y management

sotware Using the DigiSmarttrade sotware and optional

RF Antenna all units can be wirelessly connected

to a central hub or enhanced energy savings and

diagnostics Amana brand PTACs also have a low-

voltage interace capability with a ield-supplied

ront-desk ONOFF switch (See inside ront cover)

8182019 mc-dptac

httpslidepdfcomreaderfullmc-dptac 520

5Specifications and Accessories Catalog

Room Freeze Protection When the unit senses

temperatures o 40degF or below the unit activates

the an motor and either the electric resistance

heater or the hydronic heater

Easy-to-use Controls No complex controls to conuse

your guests and create phone calls or your manager

Controls are easy to read understand and activate

Our new 7-button control panel provides guests with

complete control o the unit or their in-room comort

while maintaining overall energ y e iciency

Easy to Service with On-Board LED Diagnostics

The main components are easily serviced and there

is no guessing to determine the problem with our

easy-to-read diagnostics

Stonewood Room Front Our Stonewood room ront

strikes the balance between attractive st yling and

practical design Distinctive contours and a modern

appearance enhance the character o even the most

luxurious room while the sleek 7⅝ depth maximizes

usable space or your guests

Remote Thermostat Control When the DigiSmarttradewireless remote thermostat (DS01E sold separately) is

set up both the remote thermostat and unit control

panel continue to control the unit providing lexibility

and home-like system control Installation requires no

more than pressing two buttons No need to run wires

or make electrical connections

Extended Heat Pump Heating Heat pump models

will operate in the heating mode down to as low as

24degF outdoor ambient temperature

Zero Floor Clearance The unit can be installed lush

to a inished loor i desired (Some accessories do

not have zero clearance)

30-Second Fan-Off Delay The an continues to run

30 seconds ater the compressor has stopped in either

cooling or heat pump mode and ater electric heat has

been turned o This improves eiciency by dispersing

the conditioned air on the coils into the room

Compressor Lock-In This eature helps prolong the lie

o the compressor by preventing short-cycling When

the compressor is switched rom O to On because

room temperature has risen or allen below the

speciied limit it will remain on or at least 4 minutes

I the temperature set-point is changed during this4 minutes the lock-in eature is overridden

Automatic Emergency Heat No more ldquomy unit is not

heatingrdquo complaints during the middle o the night

Heat pump units will automatically switch over to

electric resistance heat i the heat pump compressor

system ails or i the heating load is greater than the

unit capacity

Constant Fan Mode Take advantage o each unitrsquos

dual options mdash select continuous an operation or

cycle the an ON and OFF with the thermostatOur 7-button design allows guests to select an

perormance while allowing the owner to have the

unit revert to the desired program o continuous

an or cycle with conditioning

Hidden Ventilation Control The ventilation control

lever is hidden rom the occupants view to allow you

to manage ventilation requirements

High-Pressure Switch Protects the unit rom high

pressure and damage to the unit helping to ensure

long unit lie

8182019 mc-dptac

httpslidepdfcomreaderfullmc-dptac 620

6 wwwamana-ptaccom

Nomenclature

123 45 6 7 89 1415

Basic Model Type Engineering

PTC Standard Cooler PTAC Major amp Minor Revisions

PTH Standard Heat Pump PTHP

DRY Dehumid Cooler PTAC Features Code

PMC DigiAIR Cooler PTAC A Standard Model

PMH DigiAIR Heat Pump PTAC C Corrosion Protection (Seacoast)

D Power Door

Nominal Cooling Capacity F Fuse Holder (230208 Only)

07 7000 BTUh 60 Hz L Lighting Control

09 9000 BTUh 60 Hz H Hydronic Heat-Capable

10 10000 BTUh 50 Hz P Condensate Pump (PTH Only)

12 12000 BTUh 50 or 60 Hz Q Quiet STC 31 Chassis

15 15000 BTUh 60 Hz R RF Antenna

17 17000 BTUh 60 Hz V Power Vent

X placeholder

Rated Voltage W Hard-Wired (PTQC)

2 115V 60 Hz 1 Phase

3 230208V 60 Hz 1 Phase Heater Size

4 265V 60 Hz 1 Phase 00 No Electric Heat 35 35 kW (230208V)

5 240220V 50 Hz 1 Phase Export 15 15 kW 37 kW (265V)

25 25 kW 50 50 kW

Design Series

G R-410A Use up to 4 as needed in alphabetical order Examples

PTC12350AXXX PTC07335CRXX

PTC12350CXXX PTC07325CQRW

AXXX AA

10111213

PTC 07 3 G 35

Power Cord Configuration

Power Receptacle Configuration

NEMA6-15R 250V

receptacle used on

230208V units

NEMA6-20R 250V

receptacle used on

230208V units

NEMA6-30R 250V

receptacle used on

230208V units

NEMA7-20R 277V receptacle

used on 265V units

NEMA7-30R 277V receptacle

used on 265V units

G

W

20 amp

G W

30 amp

15 amp 20 amp 30 amp

277V Rating Power Cord Plugs

NEMA 7 Configuration

250V Rating Power Cord Plugs with LCDI Device

NEMA 6 Configuration

Power Cord Plugs

All units come with factor-installed power cords

All units less than 250 volts come with LCDI device

8182019 mc-dptac

httpslidepdfcomreaderfullmc-dptac 720

7Specifications and Accessories Catalog

Product Speciications PTC Models mdash CoolingElectric Heat230208 Volts

Model 983094 983096 983097PTC

073GXXXPTC

093GXXXPTC

123GXXXPTC

153GXXXPTC

173GXXX

Voltage 983219 230 208 230 208 230 208 230 208 230 208Capacity (BTUh) 7700 7700 9000 9000 12000 11700 15000 14700 16400 16200Amps 983225⁰ 35 35 41 41 56 56 70 70 84Watts 983225⁰ 658 658 796 783 1114 1085 1500 1470 1740 1720EER 117 117 113 115 104 105 100 100 94

Unit without Electric Heater

Min Circuit Amps 983090 983092 983089983088 42 49 68 85 102

CFM (CoolWet Coil)High 290 290 290 340 340Low 264 264 264 314 314

CFM (Dry Coil)

High 310 310 310 360 360

Low 282 282 282 332 332Ventilated Air CFM (Fan Only) 65 65 65 65 65Dehumidification (PintsHr) 17 22 36 44 48Net Weight (lbs) 98 102 102 113 113Ship Weight (lbs) 113 117 119 130 130

265277 Volts

Model 983089 983094 983096PTC

074GXXXPTC

094GXXXPTC

124GXXXPTC

154GXXX

Voltage 983225 983219 265 265 265 265Capacity (BTUh) 7700 9000 12000 14800Amps 983225⁰ 30 36 48 60Watts 983225⁰ 658 796 1154 1480EER 117 113 104 100

Unit without Electric Heater

Min Circuit Amps 983090 983092983089983088 36 44 59 74

CFM (CoolWet Coil)High 290 290 290 340Low 264 264 264 314

CFM (Dry Coil)High 310 310 310 360Low 282 282 282 332

Ventilated Air CFM (Fan Only) 65 65 65 65Dehumidification (PintsHr) 17 22 36 44Net Weight (lbs) 98 102 102 113Ship Weight (lbs) 113 117 119 130

Actual vent CFM perormance will vary due to application and installation conditions

N983151983156983141983155983225 All 265-volt models must use an Amanareg brand sub-base (PTSB4E) or an Amanareg brand hard-wire kit PTPWHWK4 and

disconnect switch PSHW04A

983218 Minimum Circuit Ampacity (MCA) ratings conorm to the National Electric Code however local codes should apply

983219 Minimum voltage on 230208-volt models is 197 volts maximum is 253 volts Minimum voltage on 265-volt models is 239 volts

maximum is 292 volts⁴ Overcurrent protection or all units without electric heaters is 15 amps Overcurrent protection on 265-volt models must be

cartridge-style time-delay uses (included and actory-installed on all Amana reg brand 265-volt chassis) See heater perormance

⁵ Heating capacity and efficiency based on unit operation without condensate pump unit automatically switches to electricheat at approximately 24degF outdoor ambient

⁶ Speciy two-digit heater kW size to complete model number

⁷ R-410A rerigerant used in all systems

⁸ All units meet or exceed ASHRAE 901 standards

⁹ All units less than 250 volts have a Leak Current Detector Interrupter (LCDI) power cord and meet UL 484 standards

983225⁰ Reer to electric heat perormance data or total MCA and recommended overcurrent protection Amps and Watts notationreers to compressor only

8182019 mc-dptac

httpslidepdfcomreaderfullmc-dptac 820

8 wwwamana-ptaccom

Product Speciications PTH Models mdash CoolingHeat PumpElectric HeatM983151983140983141983148 983089 983094 983096 983097

PTH073GAXXX

PTH093GAXXX

PTH123GAXXX

PTH153GAXXX

PTH074GAXXX

PTH094GAXXX

PTH124GAXXX

PTH154GAXXX

Voltage 983225 983219 230 208 230 208 230 208 230 208 265 265 265 265

Capacity (BTUh) 7600 7600 9000 900012000 12000

14700 14700

7600 9100 12000 14600

Amps 983225⁰ 39 39 42 42 58 58 70 70 31 37 50 61

Watts 983225⁰ 650 633 750 750 1090 1090 1515 1515 650 758 1091 1505

EER 117 120 120120 110110 97 97 117 120 110 97

U983150983145983156 983159983145983156983144983151983157983156 E983148983141983139983156983154983145983139 H983141983137983156983141983154

Min Circuit Amps 983090 983092983089983088 47 51 71 85 38 45 61 74

CFM (CoolWet Coil) High 340 330 340 390 340 330 340 390Low 245 245 245 340 245 245 245 340

CFM (Dry Coil)High 370 360 370 410 370 360 370 410

Low 270 270 270 370 270 270 270 370

Ventilated Air CFM (Fan Only) 65 65 65 65 65 65 65 65

Dehumidiication (PintsHr) 17 22 36 44 17 22 36 44

Net Weight (lbs) 108 112 115 126 108 112 115 125

Ship Weight (lbs) 123 127 132 143 123 127 132 142

Actual vent CFM perormance will vary due to application and installation conditions

N983151983156983141983155983225 All 265-volt models must use an Amanareg brand sub-base (PTSB4E) or an Amanareg brand hard-wire kit (PTPWHWK4)983218 Minimum Circuit Ampacity (MCA) ratings conorm to the National Electric Code however local codes should apply

Minimum voltage on 230208-volt models is 197 volts maximum is 253 volts983219 Minimum voltage on 265-volt models is 239 volts maximum is 292 volts⁴ Overcurrent protection or all units without electric heaters is 15 amps Overcurrent protection on 265-volt models must be

cartridge-style time-delay uses (included and actory-installed on all Amanareg brand 265-volt chassis)⁵ Heating capacity and efficiency based on unit operation without condensate pump unit automatically switches to electric

heat at approximately 24degF outdoor ambient⁶ Speciy two-digit heater kW size to complete model number⁷ R-410A rerigerant used in all systems⁸ All units meet or exceed ASHRAE 901 standards⁹ All units less than 250 volts have a Leak Current Detector Interrupter (LCDI) power cord and meet UL 484 standards983225⁰ Reer to electric heat perormance data or total MCA and recommended overcurrent protection Amps and Watts notation

reers to compressor only

8182019 mc-dptac

httpslidepdfcomreaderfullmc-dptac 920

9Specifications and Accessories Catalog

Actual vent CFM perormance will vary due to application and installation conditions

N983151983156983141983155983225 Minimum Circuit Ampacity (MCA) ratings conorm to the National Electric Code however local codes should apply983090 Minimum voltage on 115-volt models is 109 volts maximum is 127 volts983091 Overcurrent protection or all units without electric heaters is 15 amps⁴ R-410A rerigerant used in all systems

⁵ All units meet or exceed ASHRAE 901 standards⁶ All units less than 250 volts have a Leak Current Detector Interrupter (LCDI) power cord and meet UL 484 standards

M983151983140983141983148 983093 983094PTC

072GXXXPTC

092GXXX

Voltage 983090 115 115

Capacity (BTUh) 7000 9000

Amps 69 83

Watts 585 795

EER 119 113

Min Circuit Amps 983089 983091 83 101

CFM (CoolWet Coil)High 290 290

Low 264 264

CFM (Dry Coil)High 310 310

Low 282 282

Ventilated Air (Fan Only) 65 65

Dehumidiication (PintsHr) 17 23

Net Weight (lbs) 98 102

Ship Weight (lbs) 113 117

Product Speciications PTC 115-Volt Models mdashCoolingHydronic Heat or No-Heat Models

8182019 mc-dptac

httpslidepdfcomreaderfullmc-dptac 1020

10 wwwamana-ptaccom

Product Speciications PTH Models mdash Reverse-Cycle Heating PerormanceH983141983137983156983145983150983143

C983137983152983137983139983145983156983161983225PTH073G

AXXXPTH093G

AXXXPTH123G

AXXXPTH153G

AXXXPTH074G

AXXXPTH094G

AXXXPTH124G

AXXXPTH154G

AXXX

Voltage 983225 983219 230 208 230 208 230 208 230 208 265 265 265 265

BTUh ⁵ 6800 6800 8300 8100 11500 11300 13800 13600 6800 8300 11400 13700

Amps 983225⁰ 39 39 42 42 58 58 70 70 31 37 50 61

Watts 983225⁰ 585 585 715 700 1085 1035 1350 1330 585 715 1080 1340

COP ⁵ 34 34 34 34 31 32 30 30 34 34 31 30

CFM (Dry) 370 360 370 410 370 360 370 410

COP = Coefficiency o Perormance per AHRI Test Procedures units are rated or capacities and efficiencies

N983151983156983141983155

983225 All 265-volt models must use an Amanareg brand sub-base (PTSB4E) or an Amanareg brand hard-wire kit (PTPWHWK4)983218 Minimum branch circuit ampacity ratings conorm to the National Electric Code however local codes should apply983219 Minimum voltage on 230208-volt models is 197 volts maximum is 253 volts

Minimum voltage on 265-volt models is 239 volts maximum is 292 volts⁴ Overcurrent protection or all units without electric heaters is 15 amps Overcurrent protection on 265-volt models must

be cartridge-style time-delay uses (included and actory-installed on all Amanareg brand 265-volt chassis)⁵ Heating capacity and efficiency based on unit operation without condensate pump unit automatically switches to electric

heat at approximately 24degF outdoor ambient⁶ Speciy two-digit heater kW size to complete model number⁷ R-410A rerigerant used in all systems⁸ All units meet or exceed ASHRAE 901 standards⁹ All units less than 250 volts have a Leak Current Detector Interrupter (LCDI) power cord and meet UL 484 standards983225⁰ Reer to electric heat perormance data or total MCA and recommended overcurrent protection

Amps and Watts notation reers to compressor only

Product Speciications PTC PTH Models mdash Electric Heat Perormance(Primary Heating or PTC Models Auxiliary Heating or PTH Models See below or Power Cord Coniguration)

V983151983148983156983137983143983141E983148983141983139983156983154983145983139H983141983137983156983141983154

S983145983162983141 (983147W)

N983151 983151983142S983156983137983143983141983155

N983151983149983145983150983137983148 H983141983137983156983145983150983143 (BTU983144)T983151983156983137983148

W983137983156983156983155983094T983151983156983137983148 A983149983152983155

M983145983150 C983145983154983139983157983145983156 A983149983152983137983139983145983156983161983218

MOP983092(983137983149983152983155)

P983151983159983141983154C983151983154983140

10486269830911048624V 104862610486241048632V 104862610486301048629V

230208V 15 13 1 5100 4200 - - 1570 1295 68 62 85 15 6-15 P

230208V 25 21 1 8500 6800 - - 2570 2115 112 101 141 15 6-15 P

230208V 35 30 1 12000 9900 - - 3570 2935 155 141 195 20 6-20 P

230208V 50 41 1 17100 14000 - - 5070 4160 221 200 276 30 6-30 P

265V 15 1 - - - - 5100 1570 59 74 15 7-20P

265V 25 1 - - - - 8500 2570 97 122 15 7-20 P

265V 37 1 - - - - 12600 3770 142 179 20 7-20 P265V 5 1 - - - - 17100 5070 192 239 25 7-30 P

N983151983156983141983155983225 All 265-volt models must use an Amanareg brand sub-base (PTSB4E) or an Amanareg brand hard-wire kit (PTPWHWK4)983218 Minimum branch circuit ampacity ratings conorm to the National Electric Code however local codes should apply983219 Minimum voltage on 230208-volt models is 197 volts maximum is 253 volts Minimum voltage on 265-volt models is 239 volts maximum is 292 volts⁴ Overcurrent protection or all units without electric heaters is 15 amps Overcurrent protection on 265-volt models must be cartridge-style

time-delay uses (included and actory-installed on all Amanareg brand 265-volt chassis)⁵ Heating capacity and efficiency based on unit operation without condensate pump unit automatically switches to electric heat at

approximately 24degF outdoor ambient⁶ Total watts or 15000 BTUh models subtract 20 watts or PT070912⁷ Speciy two-digit heater kW size to complete model number⁸ R-410A rerigerant used in all systems⁹ All units meet or exceed ASHRAE 901 standards983225⁰ All units less than 250 volts have a Leak Current Detector Interrupter (LCDI) power cord and meet UL 484 standards

8182019 mc-dptac

httpslidepdfcomreaderfullmc-dptac 1120

11Specifications and Accessories Catalog

AccessoriesW983137983148983148 S983148983141983141983158983141983155All our wall sleeves have industry standard dimensionso 42 wide x 16⅟ ₁₆ high The WS900E SC and INTERNAL14⅛ depth is the industry standard Sleeves maybe shipped separately to allow or installationduring construction

C983151983150983140983141983150983155983137983156983141 D983154983137983145983150 K983145983156Attaches to the wall sleeve base pan or controlledinternal or external disposal o condensate

L983151983159983085V983151983148983156983137983143983141 W983145983154983141 H983137983154983150983141983155983155 K983145983156 (983150983151983156 983155983144983151983159983150)For quick connections o the remote or wiredthermostats wired EMS or ront desk with jumpers andconnectors

R983141983149983151983156983141 E983155983139983157983156983139983144983141983151983150 K983145983156 (983150983151983156 983155983144983151983159983150)Optional kit or use with units controlled via a wiredremote thermostat Covers control touch-pad or wiredthermostat installations

Each ldquoBrdquo kit contains 80 wires and wire nutsenough to attach a thermostat and oneadditional accessory to 10 PTAC units Wirescome in assorted colors or easy attachmentEach ldquoArdquo kit contains 10 Escutcheon plates only

O983157983156983140983151983151983154 G983154983145983148983148983141983155Available in stamped-aluminum or architecturallylouvered or application with an Amana brand WS900Ewall sleeve

AGK Extruded aluminum architectural grille availablewith anodized aluminum inish or a baked-on paintinish or durability Choose rom 3 stock colors or acustom color to blend with your buildingrsquos exteriorcolor scheme Colors include

CB (Clear Anodized) DB (Dark BrownBronze)TB (Stonewood Beige) WB (White)SB (SpecialCustom Colors)

PGK One-piece injection molded grille using a polymerblend o engineered thermoplastic high-impactstrength material with chemical resistance andan exterior UV protective coating

Choose from 3 stock colorsDB (Dark BrownBronze) TB (Stonewood Beige)

WB (White)

S983156983137983150983140983137983154983140983085D983141983152983156983144 S983148983141983141983158983141983155

WS900E-GS Heavy Sound Isolation Insulation Sleeve

WS900E Standard PTAC sleeve

WS900SC Seacoast triple protected

WS900D-INTERNAL

Internal drain only or window-wallinstallations (DK900D sold separately)

E983160983156983154983137 D983141983141983152 S983148983141983141983158983141983155 in several depths orthicker wall installations or special roomconigurations

WS9XXD1 16 to 24 in 1 increments

WS928D1 Extra deep 28

WS930D1 Extra deep 30

WS936D1 Extra deep 36

WS9XXD1-Interna

Extra deep Internal drain onlyor window-wall installations(DK900D sold separately) 1 4

⅛ 4 2

1 6

1

1 6

S983156983137983150983140983137983154983140 O983157983156983140983151983151983154 G983154983145983148983148983141

SGK01B Single Pack

SGK01TB Stonewood Beige

A983154983139983144983145983156983141983139983156983157983154983137983148 O983157983156983140983151983151983154 G983154983145983148983148983141

AGK01CB Anodized Aluminum

AGK01DB Dark BronzeBrown

AGK01TB Stonewood Beige

AGK01WB Amana White

AGK01SB Custom Colors

PGK01DB Dark BronzeBrown

PGK01TB Stonewood Beige

PGK01WB Amana White

AGKor

PGK

SGK

DK900DCondensate Drain Kit(use with WS900E)

DK9001DCondensate Drain Kit(use with WS900B)

DK900D

PWHK01C Wire Harness Kit

REK10BRemote Escutcheon Kit(10-pack)

REK10A Remote Escutcheon Plates

8182019 mc-dptac

httpslidepdfcomreaderfullmc-dptac 1220

12 wwwamana-ptaccom

Accessories (cont)S983157983138983085983138983137983155983141 K983145983156The ully skirted sub-base conceals wiring whileproviding strong support i needed Plug-in receptacleand ield-wiring access speeds installation Electricalaccessories such as use holders circuit breakers anddisconnect switches meet NEC requirements

L983141983158983141983148983145983150983143 L983141983143983155Gives wall sleeve ront support and helps to level theunit or installation

H983137983154983140983085983159983145983154983141 K983145983156983155Used to permanently wire to the chassis when astandard sub-base and power cord are not utilized

F983137983139983156983151983154983161 I983150983155983156983137983148983148983141983140 Feature Code - W

P983151983159983141983154 D983145983155983139983151983150983150983141983139983156 S983159983145983156983139983144The PSHWA power disconnect switch can be usedor 265-volt or 230208-volt physical disconnectwhere required by local codes The switch is ratedat 30-amp capacity The switch is or use with andAmanareg brand standard sub-bases or PTPWHWK4Hard Wire Kit

F983157983155983141 H983151983148983140983141983154 K983145983156Cartridge-style uses can be installed in the useholder or use in the sub-base or chassis Available in15 20 and 30 amp (included on 265-volt unit)

C983145983154983139983157983145983156 B983154983141983137983147983141983154 K983145983156 (983090983091983088983090983088983096V 983151983150983148983161)The circuit breaker kit available in 15 20 or 30 ampcan be used with Amana brand sub-bases It givesovercurrent protection and its location allows you toturn the unit on or off without tools

PTSB215E 115V15A

PTSB320E 230208V 1520A

PTSB330E 230208V 30A

PTSB420E 265V 1520A

PTSB430E 265V 25A

PTSB000E Non-electrical

LL2B Leveling legs or WS9 sleeves

PTPWHWK4 Armored Cable ndash all voltages

PTQC3A Quick Connect ndash 230208V

PTQC4A Quick Connect ndash 265 amp 115 V

PSHW03A 230208V

PSHW04A 265V

FHK315E 230208V 15A

FHK315E 230208V 15A (R-410A)

FHK320C 230208V 20A

FHK320E 230208V 20A (R-410A)

FHK330C 230208V 30A

FHK330E 230208V 30A (R-410A)

CBK15C 15 amp Circuit Breaker Kit

CBK20C 20 amp Circuit Breaker Kit

CBK30C 30 amp Circuit Breaker Kit

8182019 mc-dptac

httpslidepdfcomreaderfullmc-dptac 1320

13Specifications and Accessories Catalog

Accessories (cont)

P983151983159983141983154 V983141983150983156 K983145983156Installation o Power Vent increases CFM up toapproximately 95 Vent door will automatically closewhen unit an is off

F983137983139983156983151983154983161 I983150983155983156983137983148983148983141983140 Feature Code - VR-410A models must have these kits installed atthe actory

C983151983150983140983141983150983155983141983154 B983137983142983142983148983141 K983145983156For use on non-baffled grilles These delectors directthe air in toward the center and away rom the inlet toprevent recirculation o the hot condenser air

S983157983138983085983138983137983155983141 E983160983156983141983150983155983145983151983150 C983151983158983141983154 K983145983156Converts older 30-amp sub-bases to allow or installationo the larger 30-amp LCDI power cord and plugs

S983141983139983157983154983145983156983161 K983141983161 L983151983139983147983155In conjunction with the tamper-resistant ront theinstallation o Amanareg brand security key locks preventstampering o the controls used to set temperature heatingand cooling unctions UL approved or institutionaluse only

C983151983150983140983141983150983155983137983156983141 R983141983149983151983158983137983148 P983157983149983152Can be ield-installed Assists in removing condensatedeveloped by heat pump operation and transers it to

indoor coil to dissipate into room while adding humidityto the room

F983137983139983156983151983154983161 I983150983155983156983137983148983148983141983140 Feature Code - P

PVK3A 230208V ndash R-22

PVK4A 265V ndash R-22

D983157983139983156 E983160983156983141983150983155983145983151983150 K983145983156Extends air distribution to an adjoining room Consistsof a main duct for the room of origin and an extensionduct to reach the adjoining room and terminal ductPTDK01A allows for the ldquoBrdquo series unit to work with theldquoArdquo series duct kits

MDK02B Main Duct ndash R-22

MDK01E Main Duct ndash R-410A

EDK02B 42 Extension Duct

TRANSITION BAFFLES

Main Duct Kit

TDK02B Terminal Duct

PTDK01A Transition Duct Only ndash R-22

PTDK01E Transition Duct Only ndash R-410A

Extension Duct Kit

Terminal Duct Kit

DGK1B Condenser Baffle Kit

SBEC10A 10 Pack

Basepan

Condenser

Condenser Baffles

KL03B Security Key Lock (R-22)

KL03E Security Key Lock (R-410A)

CDP302 230208V ndash R-22

CDP402 265V ndash R-22

CDP303E 230208V ndash R-410A

8182019 mc-dptac

httpslidepdfcomreaderfullmc-dptac 1420

14 wwwamana-ptaccom

Accessories (cont)

HWK03B Hydronic Water Kit ndash R-22

HVK03B Hydronic Steam Kit ndash R-22

HWK03E Hydronic Water Kit ndash R-410A

HVK03E Hydronic Steam Kit ndash R-410A

ThermostatsThe ollowing thermostats offer remote control Any thermostat other than those listed must be submitted to Goodman Company LPor approval prior to use

H983161983140983154983151983150983145983139 H983141983137983156 K983145983156Add-on kits it all units allowing the addition o hydronicwater or hydronic steam heat to cooling and heating unitsThe kits eature lef- or right-hand piping Unit retainscomplete service access with a kit installed Unit must beconnected to and operated by a wall thermostat

Hydronic Heat Kit Top View

Hydronic Heat Kit Right View

M983151983140983141983148 H983141983137983156 S983156983137983143983141983155 C983151983151983148 S983156983137983143983141983155 F983137983150 S983152983141983141983140 983151983142 W983145983154983141983155R983141983153983157983145983154983141983140

T983141983149983152L983145983149983145983156983145983150983143

B983137983139983147983148983145983156 D983145983155983152983148983137983161 T983161983152983141S983144983137983152983141 983078

O983154983145983141983150983156983137983156983145983151983150C983151983150983150983141983139983156983145983151983150

2246002 1 1 1 5 No Yes Digital Manual RectHoriz Wired

2246003 2 2 2 7 Yes Yes Digital Manual RectHoriz Wired

2246007 2 2 1 7 Yes Yes Digital Auto-Change RectHoriz Wired

2246008 2 2 1 7 Yes Yes Digital Programmable RectHoriz Wired

DS01E 2 2 2 0 Yes Yes Digital Manual RectHoriz Wireless

Battery powered but has optional hard wire capability Requires DT01G Antennae or operation

Hydronic Heat KitSide View

8182019 mc-dptac

httpslidepdfcomreaderfullmc-dptac 1520

15Specifications and Accessories Catalog

Accessories (cont)P983151983159983141983154 D983151983151983154 K983145983156Vent door will automatically open when unit an is on

Factory Installed Feature Code - D

H983161983140983154983151983150983145983139 V983137983148983158983141983155Water and steam valves are available or use with theHWK03 (water) and HVK03 (steam) heat kits

W983145983154983141983148983141983155983155 RF (R983137983140983145983151 F983154983141983153983157983141983150983139983161) C983151983150983156983154983151983148983155All DigiSmart PTACs come actory-ready to be con-trolledvia wireless RF devices 24 Ghz 802 154 protocol assuresrobust communications and response

W983137983148983148 S983148983141983141983158983141 E983160983156983141983150983155983145983151983150 A983140983137983152983156983141983154 K983145983156983155Room-side extension kits to increase the depth o theexisting sleeve to allow or an industry-standard PTAC tobe installed

C983157983154983156983137983145983150 B983137983142983142983148983141 K983145983156The color matched polymer curtain baffles help toprevent curtains rom alling into the discharge airstream and causing recirculation reducing efficienciesand shortening compressor lie

PDK3A 230208V ndash R-22

PDK4A 265V ndash R-22

PDK3E 230208V ndash R-410A

PDK4E 265V ndash R-410A

VS2WNCA 2-way24VNCSteam VS2WNOA 2-way24VNOSteam VW2WNCA 2-way24VNCEnd Switch

VW2WNOA 2-way24VNOEnd Switch VW3WNC2B 3-way24VNCNOEnd Switch

Poptop Actuator

DS01EThermostat 2-way2 Communications

DD01EOccupancy SensorEMS Activation2

DT01GAntenna RouterFactory InstalledFeature Code - R

GT01GGeneric RadioAntenna Router3

DD01F Door Switch EMS Activation2

DP01G Web-enabled Platorm Server

DL01GWeb-enabled PlatormServer Link BAC-NET capable

DR01G Mesh Repeater1

DL01G-SERIAL

Serial Repeater1

1 Consult Amana Sales representative priorto purchase

2 Requires DT01G or use3 Requires DS01E or use

SECM1001A 15 Extension or 12frac12 Climate Master Sleeve (10 Pack)

SEZA0501A 25 Extension or 11frac12 Zone Air Sleeve (5 pack)

PTCB10B 10 Pack or R-22 units

PTCB10E 10 Pack or R-410A units

8182019 mc-dptac

httpslidepdfcomreaderfullmc-dptac 1620

16 wwwamana-ptaccom

Unit with Accessory Wall Sleeve and Sub-base Accessory

3

11

6- 18 9- 91624 -5 16

40

42

Location of external drain holes on bottom flange of Wall Sleeve

3 Clearance

to side walls

Air Flow

Air Flow

Air Flow

Air Discharge Grille ControlDoor

T983151983152 V983145983141983159

F983154983151983150983156 V98314598314198315958 LCDI CORD SET mdash 230V208V UNIT

58 CORD SET 230V208V UNIT

18 CORD SET 2 65V UNIT

3-14

MIN

2

MAX

2-58

42

16-116

RI GHTLEFT

1 and frac34 Concentric knock-outs back ampbottom o sub-base (electrical only)

R983145983143983144983156 V983145983141983159

2frac34

4

11⅜

983225983219 frasl ₁₆

983225983219 frasl ₁₆ 1⅜

16983225 frasl ₁₆

1⅜Arch Grille

⅞Stamped Grille

14⅛Wall Sleeve

21frac12

7⅜

Optional

Sub-base

HingedControlDoor

15deg

40deg

Air discharge grille is reversible to provideeither 15deg or 40deg discharge angle

frac12 ODCopperDrain Tube

8182019 mc-dptac

httpslidepdfcomreaderfullmc-dptac 1720

17Specifications and Accessories Catalog

Framing or Accessory Wall Sleeve (WS9XX)F983137983155983156983141983150983145983150983143 W983137983148983148 S983148983141983141983158983141When installed in an opening the Wall Sleeve must behorizontally level (side-to-side) and pitched frac14 bubble to the outside

(NOTE To ensure unitrsquos maximum efficiency DO NOT over- or under-pitch)

I983150983155983156983137983148983148983137983156983145983151983150 N9831519831569831419831551 I Sub-base (PTSBE) is installed allow minimum

3frac14 height clearance and maximum 5 heightclearance between wall sleeve and loor allowminimum 2frac34 protrusion rom a inished wallSee Note 4 if using hydronic units

2 Drain Kit (DK900D) shipped separately Can bemounted either right side lef side or bottom osleeve I mounted to bottom o sleeve allow2 height clearance rom loor to bottom o sleeve

3 For UL approval 265V units must use Amanareg brandSub-base (PTSBE) or Amanareg brand Hard WireKit (PSHW04A) Overcurrent protection on 265V unitsmust be by cartridge-style time delay uses whichare included and factory-installed on the Amanareg brand 265V chassis

4 I Hydronic Kit (HWK03 or HVK03) is installedWall Sleeve must extend exactly 3 into the roomrom the inished interior wall I using the Amana reg brand Sub-base (PTSBE) only the minimum3frac14 height clearance between wall sleeve and loor

is permissible Unit must also be operated with aremote-mounted thermostat

5 I Duct Kit (MDK) is installed allow a minimum o2⅜ into the room rom the inished interior wall

MountingHoles(Drilled byInstaller)

PlasticAnchor

Screws

ExpansionAnchor Bolt

Toggle Bolt

Wood Screw

AlternativeFastening Method(Field Supplied)

Wall Sleeve must extend a minimum o frac14 beyond outside wall to allow orproper caulking

FINISHED FLOOR

4 2 1 4

16 14

MIN

MAIN STUD

JACK STUDS

HEADER - 4 x 4 OR

DOUBLE 2x 4 ON EDGE

SUB-FLOOR

CRIPPLE

JACK STUD

ADJUST FRAMING TO

SECURE THIS DIMENSION

Wall sleeve opening height should be squared withwall sleeve opening width

H = 16frac14

W = 42frac14

8182019 mc-dptac

httpslidepdfcomreaderfullmc-dptac 1820

Notes

8182019 mc-dptac

httpslidepdfcomreaderfullmc-dptac 1920

Our continuing commitment to quality products may mean a change in speciications without noticecopy 2015 Goodman Company LP Amana is a registered trademark o Maytag Corporation or its related

companies and is used under license to Goodman Company LP Houston TX USA All rights reserved

Quiet two-an motor system

Energy-eicient perormance

DigiSmartreg wireless controls on select models

Wise DecisionItrsquos an Amanareg brand

8182019 mc-dptac

httpslidepdfcomreaderfullmc-dptac 2020

Our continuing commitment to quality products may mean a change in speciications without notice copy 2015 Goodman Company LPAmana is a registered trademark o Maytag Corporation or its related companies and is used under license to Goodman Company L P

wwwamana-ptaccom

Call your Amana brand PTAC sales representative at 800-647-2982 or complete details

Beore purchasing this appliance read important inormation about its estimated annual energy

consumption yearly operating cost or energy efficiency rating that is available rom your retailer

A legacy o comortThe impeccable reputation oan American original

Amana heating and cooling systems are a part of the

enduring legacy of one of Americarsquos most recognized

and respected brands Originating eight decades ago in

Amana Iowa the brand is synonymous with long-last-

ing premium-quality products mdash from home appliances

to heating and air conditioning equipment Chances

are you and generations beore you have enjoyed the

dependable performance and longevity the Amana

brand continues to deliver

MC-DPTAC 07-15Supersedes 06-15

Page 5: mc-dptac

8182019 mc-dptac

httpslidepdfcomreaderfullmc-dptac 520

5Specifications and Accessories Catalog

Room Freeze Protection When the unit senses

temperatures o 40degF or below the unit activates

the an motor and either the electric resistance

heater or the hydronic heater

Easy-to-use Controls No complex controls to conuse

your guests and create phone calls or your manager

Controls are easy to read understand and activate

Our new 7-button control panel provides guests with

complete control o the unit or their in-room comort

while maintaining overall energ y e iciency

Easy to Service with On-Board LED Diagnostics

The main components are easily serviced and there

is no guessing to determine the problem with our

easy-to-read diagnostics

Stonewood Room Front Our Stonewood room ront

strikes the balance between attractive st yling and

practical design Distinctive contours and a modern

appearance enhance the character o even the most

luxurious room while the sleek 7⅝ depth maximizes

usable space or your guests

Remote Thermostat Control When the DigiSmarttradewireless remote thermostat (DS01E sold separately) is

set up both the remote thermostat and unit control

panel continue to control the unit providing lexibility

and home-like system control Installation requires no

more than pressing two buttons No need to run wires

or make electrical connections

Extended Heat Pump Heating Heat pump models

will operate in the heating mode down to as low as

24degF outdoor ambient temperature

Zero Floor Clearance The unit can be installed lush

to a inished loor i desired (Some accessories do

not have zero clearance)

30-Second Fan-Off Delay The an continues to run

30 seconds ater the compressor has stopped in either

cooling or heat pump mode and ater electric heat has

been turned o This improves eiciency by dispersing

the conditioned air on the coils into the room

Compressor Lock-In This eature helps prolong the lie

o the compressor by preventing short-cycling When

the compressor is switched rom O to On because

room temperature has risen or allen below the

speciied limit it will remain on or at least 4 minutes

I the temperature set-point is changed during this4 minutes the lock-in eature is overridden

Automatic Emergency Heat No more ldquomy unit is not

heatingrdquo complaints during the middle o the night

Heat pump units will automatically switch over to

electric resistance heat i the heat pump compressor

system ails or i the heating load is greater than the

unit capacity

Constant Fan Mode Take advantage o each unitrsquos

dual options mdash select continuous an operation or

cycle the an ON and OFF with the thermostatOur 7-button design allows guests to select an

perormance while allowing the owner to have the

unit revert to the desired program o continuous

an or cycle with conditioning

Hidden Ventilation Control The ventilation control

lever is hidden rom the occupants view to allow you

to manage ventilation requirements

High-Pressure Switch Protects the unit rom high

pressure and damage to the unit helping to ensure

long unit lie

8182019 mc-dptac

httpslidepdfcomreaderfullmc-dptac 620

6 wwwamana-ptaccom

Nomenclature

123 45 6 7 89 1415

Basic Model Type Engineering

PTC Standard Cooler PTAC Major amp Minor Revisions

PTH Standard Heat Pump PTHP

DRY Dehumid Cooler PTAC Features Code

PMC DigiAIR Cooler PTAC A Standard Model

PMH DigiAIR Heat Pump PTAC C Corrosion Protection (Seacoast)

D Power Door

Nominal Cooling Capacity F Fuse Holder (230208 Only)

07 7000 BTUh 60 Hz L Lighting Control

09 9000 BTUh 60 Hz H Hydronic Heat-Capable

10 10000 BTUh 50 Hz P Condensate Pump (PTH Only)

12 12000 BTUh 50 or 60 Hz Q Quiet STC 31 Chassis

15 15000 BTUh 60 Hz R RF Antenna

17 17000 BTUh 60 Hz V Power Vent

X placeholder

Rated Voltage W Hard-Wired (PTQC)

2 115V 60 Hz 1 Phase

3 230208V 60 Hz 1 Phase Heater Size

4 265V 60 Hz 1 Phase 00 No Electric Heat 35 35 kW (230208V)

5 240220V 50 Hz 1 Phase Export 15 15 kW 37 kW (265V)

25 25 kW 50 50 kW

Design Series

G R-410A Use up to 4 as needed in alphabetical order Examples

PTC12350AXXX PTC07335CRXX

PTC12350CXXX PTC07325CQRW

AXXX AA

10111213

PTC 07 3 G 35

Power Cord Configuration

Power Receptacle Configuration

NEMA6-15R 250V

receptacle used on

230208V units

NEMA6-20R 250V

receptacle used on

230208V units

NEMA6-30R 250V

receptacle used on

230208V units

NEMA7-20R 277V receptacle

used on 265V units

NEMA7-30R 277V receptacle

used on 265V units

G

W

20 amp

G W

30 amp

15 amp 20 amp 30 amp

277V Rating Power Cord Plugs

NEMA 7 Configuration

250V Rating Power Cord Plugs with LCDI Device

NEMA 6 Configuration

Power Cord Plugs

All units come with factor-installed power cords

All units less than 250 volts come with LCDI device

8182019 mc-dptac

httpslidepdfcomreaderfullmc-dptac 720

7Specifications and Accessories Catalog

Product Speciications PTC Models mdash CoolingElectric Heat230208 Volts

Model 983094 983096 983097PTC

073GXXXPTC

093GXXXPTC

123GXXXPTC

153GXXXPTC

173GXXX

Voltage 983219 230 208 230 208 230 208 230 208 230 208Capacity (BTUh) 7700 7700 9000 9000 12000 11700 15000 14700 16400 16200Amps 983225⁰ 35 35 41 41 56 56 70 70 84Watts 983225⁰ 658 658 796 783 1114 1085 1500 1470 1740 1720EER 117 117 113 115 104 105 100 100 94

Unit without Electric Heater

Min Circuit Amps 983090 983092 983089983088 42 49 68 85 102

CFM (CoolWet Coil)High 290 290 290 340 340Low 264 264 264 314 314

CFM (Dry Coil)

High 310 310 310 360 360

Low 282 282 282 332 332Ventilated Air CFM (Fan Only) 65 65 65 65 65Dehumidification (PintsHr) 17 22 36 44 48Net Weight (lbs) 98 102 102 113 113Ship Weight (lbs) 113 117 119 130 130

265277 Volts

Model 983089 983094 983096PTC

074GXXXPTC

094GXXXPTC

124GXXXPTC

154GXXX

Voltage 983225 983219 265 265 265 265Capacity (BTUh) 7700 9000 12000 14800Amps 983225⁰ 30 36 48 60Watts 983225⁰ 658 796 1154 1480EER 117 113 104 100

Unit without Electric Heater

Min Circuit Amps 983090 983092983089983088 36 44 59 74

CFM (CoolWet Coil)High 290 290 290 340Low 264 264 264 314

CFM (Dry Coil)High 310 310 310 360Low 282 282 282 332

Ventilated Air CFM (Fan Only) 65 65 65 65Dehumidification (PintsHr) 17 22 36 44Net Weight (lbs) 98 102 102 113Ship Weight (lbs) 113 117 119 130

Actual vent CFM perormance will vary due to application and installation conditions

N983151983156983141983155983225 All 265-volt models must use an Amanareg brand sub-base (PTSB4E) or an Amanareg brand hard-wire kit PTPWHWK4 and

disconnect switch PSHW04A

983218 Minimum Circuit Ampacity (MCA) ratings conorm to the National Electric Code however local codes should apply

983219 Minimum voltage on 230208-volt models is 197 volts maximum is 253 volts Minimum voltage on 265-volt models is 239 volts

maximum is 292 volts⁴ Overcurrent protection or all units without electric heaters is 15 amps Overcurrent protection on 265-volt models must be

cartridge-style time-delay uses (included and actory-installed on all Amana reg brand 265-volt chassis) See heater perormance

⁵ Heating capacity and efficiency based on unit operation without condensate pump unit automatically switches to electricheat at approximately 24degF outdoor ambient

⁶ Speciy two-digit heater kW size to complete model number

⁷ R-410A rerigerant used in all systems

⁸ All units meet or exceed ASHRAE 901 standards

⁹ All units less than 250 volts have a Leak Current Detector Interrupter (LCDI) power cord and meet UL 484 standards

983225⁰ Reer to electric heat perormance data or total MCA and recommended overcurrent protection Amps and Watts notationreers to compressor only

8182019 mc-dptac

httpslidepdfcomreaderfullmc-dptac 820

8 wwwamana-ptaccom

Product Speciications PTH Models mdash CoolingHeat PumpElectric HeatM983151983140983141983148 983089 983094 983096 983097

PTH073GAXXX

PTH093GAXXX

PTH123GAXXX

PTH153GAXXX

PTH074GAXXX

PTH094GAXXX

PTH124GAXXX

PTH154GAXXX

Voltage 983225 983219 230 208 230 208 230 208 230 208 265 265 265 265

Capacity (BTUh) 7600 7600 9000 900012000 12000

14700 14700

7600 9100 12000 14600

Amps 983225⁰ 39 39 42 42 58 58 70 70 31 37 50 61

Watts 983225⁰ 650 633 750 750 1090 1090 1515 1515 650 758 1091 1505

EER 117 120 120120 110110 97 97 117 120 110 97

U983150983145983156 983159983145983156983144983151983157983156 E983148983141983139983156983154983145983139 H983141983137983156983141983154

Min Circuit Amps 983090 983092983089983088 47 51 71 85 38 45 61 74

CFM (CoolWet Coil) High 340 330 340 390 340 330 340 390Low 245 245 245 340 245 245 245 340

CFM (Dry Coil)High 370 360 370 410 370 360 370 410

Low 270 270 270 370 270 270 270 370

Ventilated Air CFM (Fan Only) 65 65 65 65 65 65 65 65

Dehumidiication (PintsHr) 17 22 36 44 17 22 36 44

Net Weight (lbs) 108 112 115 126 108 112 115 125

Ship Weight (lbs) 123 127 132 143 123 127 132 142

Actual vent CFM perormance will vary due to application and installation conditions

N983151983156983141983155983225 All 265-volt models must use an Amanareg brand sub-base (PTSB4E) or an Amanareg brand hard-wire kit (PTPWHWK4)983218 Minimum Circuit Ampacity (MCA) ratings conorm to the National Electric Code however local codes should apply

Minimum voltage on 230208-volt models is 197 volts maximum is 253 volts983219 Minimum voltage on 265-volt models is 239 volts maximum is 292 volts⁴ Overcurrent protection or all units without electric heaters is 15 amps Overcurrent protection on 265-volt models must be

cartridge-style time-delay uses (included and actory-installed on all Amanareg brand 265-volt chassis)⁵ Heating capacity and efficiency based on unit operation without condensate pump unit automatically switches to electric

heat at approximately 24degF outdoor ambient⁶ Speciy two-digit heater kW size to complete model number⁷ R-410A rerigerant used in all systems⁸ All units meet or exceed ASHRAE 901 standards⁹ All units less than 250 volts have a Leak Current Detector Interrupter (LCDI) power cord and meet UL 484 standards983225⁰ Reer to electric heat perormance data or total MCA and recommended overcurrent protection Amps and Watts notation

reers to compressor only

8182019 mc-dptac

httpslidepdfcomreaderfullmc-dptac 920

9Specifications and Accessories Catalog

Actual vent CFM perormance will vary due to application and installation conditions

N983151983156983141983155983225 Minimum Circuit Ampacity (MCA) ratings conorm to the National Electric Code however local codes should apply983090 Minimum voltage on 115-volt models is 109 volts maximum is 127 volts983091 Overcurrent protection or all units without electric heaters is 15 amps⁴ R-410A rerigerant used in all systems

⁵ All units meet or exceed ASHRAE 901 standards⁶ All units less than 250 volts have a Leak Current Detector Interrupter (LCDI) power cord and meet UL 484 standards

M983151983140983141983148 983093 983094PTC

072GXXXPTC

092GXXX

Voltage 983090 115 115

Capacity (BTUh) 7000 9000

Amps 69 83

Watts 585 795

EER 119 113

Min Circuit Amps 983089 983091 83 101

CFM (CoolWet Coil)High 290 290

Low 264 264

CFM (Dry Coil)High 310 310

Low 282 282

Ventilated Air (Fan Only) 65 65

Dehumidiication (PintsHr) 17 23

Net Weight (lbs) 98 102

Ship Weight (lbs) 113 117

Product Speciications PTC 115-Volt Models mdashCoolingHydronic Heat or No-Heat Models

8182019 mc-dptac

httpslidepdfcomreaderfullmc-dptac 1020

10 wwwamana-ptaccom

Product Speciications PTH Models mdash Reverse-Cycle Heating PerormanceH983141983137983156983145983150983143

C983137983152983137983139983145983156983161983225PTH073G

AXXXPTH093G

AXXXPTH123G

AXXXPTH153G

AXXXPTH074G

AXXXPTH094G

AXXXPTH124G

AXXXPTH154G

AXXX

Voltage 983225 983219 230 208 230 208 230 208 230 208 265 265 265 265

BTUh ⁵ 6800 6800 8300 8100 11500 11300 13800 13600 6800 8300 11400 13700

Amps 983225⁰ 39 39 42 42 58 58 70 70 31 37 50 61

Watts 983225⁰ 585 585 715 700 1085 1035 1350 1330 585 715 1080 1340

COP ⁵ 34 34 34 34 31 32 30 30 34 34 31 30

CFM (Dry) 370 360 370 410 370 360 370 410

COP = Coefficiency o Perormance per AHRI Test Procedures units are rated or capacities and efficiencies

N983151983156983141983155

983225 All 265-volt models must use an Amanareg brand sub-base (PTSB4E) or an Amanareg brand hard-wire kit (PTPWHWK4)983218 Minimum branch circuit ampacity ratings conorm to the National Electric Code however local codes should apply983219 Minimum voltage on 230208-volt models is 197 volts maximum is 253 volts

Minimum voltage on 265-volt models is 239 volts maximum is 292 volts⁴ Overcurrent protection or all units without electric heaters is 15 amps Overcurrent protection on 265-volt models must

be cartridge-style time-delay uses (included and actory-installed on all Amanareg brand 265-volt chassis)⁵ Heating capacity and efficiency based on unit operation without condensate pump unit automatically switches to electric

heat at approximately 24degF outdoor ambient⁶ Speciy two-digit heater kW size to complete model number⁷ R-410A rerigerant used in all systems⁸ All units meet or exceed ASHRAE 901 standards⁹ All units less than 250 volts have a Leak Current Detector Interrupter (LCDI) power cord and meet UL 484 standards983225⁰ Reer to electric heat perormance data or total MCA and recommended overcurrent protection

Amps and Watts notation reers to compressor only

Product Speciications PTC PTH Models mdash Electric Heat Perormance(Primary Heating or PTC Models Auxiliary Heating or PTH Models See below or Power Cord Coniguration)

V983151983148983156983137983143983141E983148983141983139983156983154983145983139H983141983137983156983141983154

S983145983162983141 (983147W)

N983151 983151983142S983156983137983143983141983155

N983151983149983145983150983137983148 H983141983137983156983145983150983143 (BTU983144)T983151983156983137983148

W983137983156983156983155983094T983151983156983137983148 A983149983152983155

M983145983150 C983145983154983139983157983145983156 A983149983152983137983139983145983156983161983218

MOP983092(983137983149983152983155)

P983151983159983141983154C983151983154983140

10486269830911048624V 104862610486241048632V 104862610486301048629V

230208V 15 13 1 5100 4200 - - 1570 1295 68 62 85 15 6-15 P

230208V 25 21 1 8500 6800 - - 2570 2115 112 101 141 15 6-15 P

230208V 35 30 1 12000 9900 - - 3570 2935 155 141 195 20 6-20 P

230208V 50 41 1 17100 14000 - - 5070 4160 221 200 276 30 6-30 P

265V 15 1 - - - - 5100 1570 59 74 15 7-20P

265V 25 1 - - - - 8500 2570 97 122 15 7-20 P

265V 37 1 - - - - 12600 3770 142 179 20 7-20 P265V 5 1 - - - - 17100 5070 192 239 25 7-30 P

N983151983156983141983155983225 All 265-volt models must use an Amanareg brand sub-base (PTSB4E) or an Amanareg brand hard-wire kit (PTPWHWK4)983218 Minimum branch circuit ampacity ratings conorm to the National Electric Code however local codes should apply983219 Minimum voltage on 230208-volt models is 197 volts maximum is 253 volts Minimum voltage on 265-volt models is 239 volts maximum is 292 volts⁴ Overcurrent protection or all units without electric heaters is 15 amps Overcurrent protection on 265-volt models must be cartridge-style

time-delay uses (included and actory-installed on all Amanareg brand 265-volt chassis)⁵ Heating capacity and efficiency based on unit operation without condensate pump unit automatically switches to electric heat at

approximately 24degF outdoor ambient⁶ Total watts or 15000 BTUh models subtract 20 watts or PT070912⁷ Speciy two-digit heater kW size to complete model number⁸ R-410A rerigerant used in all systems⁹ All units meet or exceed ASHRAE 901 standards983225⁰ All units less than 250 volts have a Leak Current Detector Interrupter (LCDI) power cord and meet UL 484 standards

8182019 mc-dptac

httpslidepdfcomreaderfullmc-dptac 1120

11Specifications and Accessories Catalog

AccessoriesW983137983148983148 S983148983141983141983158983141983155All our wall sleeves have industry standard dimensionso 42 wide x 16⅟ ₁₆ high The WS900E SC and INTERNAL14⅛ depth is the industry standard Sleeves maybe shipped separately to allow or installationduring construction

C983151983150983140983141983150983155983137983156983141 D983154983137983145983150 K983145983156Attaches to the wall sleeve base pan or controlledinternal or external disposal o condensate

L983151983159983085V983151983148983156983137983143983141 W983145983154983141 H983137983154983150983141983155983155 K983145983156 (983150983151983156 983155983144983151983159983150)For quick connections o the remote or wiredthermostats wired EMS or ront desk with jumpers andconnectors

R983141983149983151983156983141 E983155983139983157983156983139983144983141983151983150 K983145983156 (983150983151983156 983155983144983151983159983150)Optional kit or use with units controlled via a wiredremote thermostat Covers control touch-pad or wiredthermostat installations

Each ldquoBrdquo kit contains 80 wires and wire nutsenough to attach a thermostat and oneadditional accessory to 10 PTAC units Wirescome in assorted colors or easy attachmentEach ldquoArdquo kit contains 10 Escutcheon plates only

O983157983156983140983151983151983154 G983154983145983148983148983141983155Available in stamped-aluminum or architecturallylouvered or application with an Amana brand WS900Ewall sleeve

AGK Extruded aluminum architectural grille availablewith anodized aluminum inish or a baked-on paintinish or durability Choose rom 3 stock colors or acustom color to blend with your buildingrsquos exteriorcolor scheme Colors include

CB (Clear Anodized) DB (Dark BrownBronze)TB (Stonewood Beige) WB (White)SB (SpecialCustom Colors)

PGK One-piece injection molded grille using a polymerblend o engineered thermoplastic high-impactstrength material with chemical resistance andan exterior UV protective coating

Choose from 3 stock colorsDB (Dark BrownBronze) TB (Stonewood Beige)

WB (White)

S983156983137983150983140983137983154983140983085D983141983152983156983144 S983148983141983141983158983141983155

WS900E-GS Heavy Sound Isolation Insulation Sleeve

WS900E Standard PTAC sleeve

WS900SC Seacoast triple protected

WS900D-INTERNAL

Internal drain only or window-wallinstallations (DK900D sold separately)

E983160983156983154983137 D983141983141983152 S983148983141983141983158983141983155 in several depths orthicker wall installations or special roomconigurations

WS9XXD1 16 to 24 in 1 increments

WS928D1 Extra deep 28

WS930D1 Extra deep 30

WS936D1 Extra deep 36

WS9XXD1-Interna

Extra deep Internal drain onlyor window-wall installations(DK900D sold separately) 1 4

⅛ 4 2

1 6

1

1 6

S983156983137983150983140983137983154983140 O983157983156983140983151983151983154 G983154983145983148983148983141

SGK01B Single Pack

SGK01TB Stonewood Beige

A983154983139983144983145983156983141983139983156983157983154983137983148 O983157983156983140983151983151983154 G983154983145983148983148983141

AGK01CB Anodized Aluminum

AGK01DB Dark BronzeBrown

AGK01TB Stonewood Beige

AGK01WB Amana White

AGK01SB Custom Colors

PGK01DB Dark BronzeBrown

PGK01TB Stonewood Beige

PGK01WB Amana White

AGKor

PGK

SGK

DK900DCondensate Drain Kit(use with WS900E)

DK9001DCondensate Drain Kit(use with WS900B)

DK900D

PWHK01C Wire Harness Kit

REK10BRemote Escutcheon Kit(10-pack)

REK10A Remote Escutcheon Plates

8182019 mc-dptac

httpslidepdfcomreaderfullmc-dptac 1220

12 wwwamana-ptaccom

Accessories (cont)S983157983138983085983138983137983155983141 K983145983156The ully skirted sub-base conceals wiring whileproviding strong support i needed Plug-in receptacleand ield-wiring access speeds installation Electricalaccessories such as use holders circuit breakers anddisconnect switches meet NEC requirements

L983141983158983141983148983145983150983143 L983141983143983155Gives wall sleeve ront support and helps to level theunit or installation

H983137983154983140983085983159983145983154983141 K983145983156983155Used to permanently wire to the chassis when astandard sub-base and power cord are not utilized

F983137983139983156983151983154983161 I983150983155983156983137983148983148983141983140 Feature Code - W

P983151983159983141983154 D983145983155983139983151983150983150983141983139983156 S983159983145983156983139983144The PSHWA power disconnect switch can be usedor 265-volt or 230208-volt physical disconnectwhere required by local codes The switch is ratedat 30-amp capacity The switch is or use with andAmanareg brand standard sub-bases or PTPWHWK4Hard Wire Kit

F983157983155983141 H983151983148983140983141983154 K983145983156Cartridge-style uses can be installed in the useholder or use in the sub-base or chassis Available in15 20 and 30 amp (included on 265-volt unit)

C983145983154983139983157983145983156 B983154983141983137983147983141983154 K983145983156 (983090983091983088983090983088983096V 983151983150983148983161)The circuit breaker kit available in 15 20 or 30 ampcan be used with Amana brand sub-bases It givesovercurrent protection and its location allows you toturn the unit on or off without tools

PTSB215E 115V15A

PTSB320E 230208V 1520A

PTSB330E 230208V 30A

PTSB420E 265V 1520A

PTSB430E 265V 25A

PTSB000E Non-electrical

LL2B Leveling legs or WS9 sleeves

PTPWHWK4 Armored Cable ndash all voltages

PTQC3A Quick Connect ndash 230208V

PTQC4A Quick Connect ndash 265 amp 115 V

PSHW03A 230208V

PSHW04A 265V

FHK315E 230208V 15A

FHK315E 230208V 15A (R-410A)

FHK320C 230208V 20A

FHK320E 230208V 20A (R-410A)

FHK330C 230208V 30A

FHK330E 230208V 30A (R-410A)

CBK15C 15 amp Circuit Breaker Kit

CBK20C 20 amp Circuit Breaker Kit

CBK30C 30 amp Circuit Breaker Kit

8182019 mc-dptac

httpslidepdfcomreaderfullmc-dptac 1320

13Specifications and Accessories Catalog

Accessories (cont)

P983151983159983141983154 V983141983150983156 K983145983156Installation o Power Vent increases CFM up toapproximately 95 Vent door will automatically closewhen unit an is off

F983137983139983156983151983154983161 I983150983155983156983137983148983148983141983140 Feature Code - VR-410A models must have these kits installed atthe actory

C983151983150983140983141983150983155983141983154 B983137983142983142983148983141 K983145983156For use on non-baffled grilles These delectors directthe air in toward the center and away rom the inlet toprevent recirculation o the hot condenser air

S983157983138983085983138983137983155983141 E983160983156983141983150983155983145983151983150 C983151983158983141983154 K983145983156Converts older 30-amp sub-bases to allow or installationo the larger 30-amp LCDI power cord and plugs

S983141983139983157983154983145983156983161 K983141983161 L983151983139983147983155In conjunction with the tamper-resistant ront theinstallation o Amanareg brand security key locks preventstampering o the controls used to set temperature heatingand cooling unctions UL approved or institutionaluse only

C983151983150983140983141983150983155983137983156983141 R983141983149983151983158983137983148 P983157983149983152Can be ield-installed Assists in removing condensatedeveloped by heat pump operation and transers it to

indoor coil to dissipate into room while adding humidityto the room

F983137983139983156983151983154983161 I983150983155983156983137983148983148983141983140 Feature Code - P

PVK3A 230208V ndash R-22

PVK4A 265V ndash R-22

D983157983139983156 E983160983156983141983150983155983145983151983150 K983145983156Extends air distribution to an adjoining room Consistsof a main duct for the room of origin and an extensionduct to reach the adjoining room and terminal ductPTDK01A allows for the ldquoBrdquo series unit to work with theldquoArdquo series duct kits

MDK02B Main Duct ndash R-22

MDK01E Main Duct ndash R-410A

EDK02B 42 Extension Duct

TRANSITION BAFFLES

Main Duct Kit

TDK02B Terminal Duct

PTDK01A Transition Duct Only ndash R-22

PTDK01E Transition Duct Only ndash R-410A

Extension Duct Kit

Terminal Duct Kit

DGK1B Condenser Baffle Kit

SBEC10A 10 Pack

Basepan

Condenser

Condenser Baffles

KL03B Security Key Lock (R-22)

KL03E Security Key Lock (R-410A)

CDP302 230208V ndash R-22

CDP402 265V ndash R-22

CDP303E 230208V ndash R-410A

8182019 mc-dptac

httpslidepdfcomreaderfullmc-dptac 1420

14 wwwamana-ptaccom

Accessories (cont)

HWK03B Hydronic Water Kit ndash R-22

HVK03B Hydronic Steam Kit ndash R-22

HWK03E Hydronic Water Kit ndash R-410A

HVK03E Hydronic Steam Kit ndash R-410A

ThermostatsThe ollowing thermostats offer remote control Any thermostat other than those listed must be submitted to Goodman Company LPor approval prior to use

H983161983140983154983151983150983145983139 H983141983137983156 K983145983156Add-on kits it all units allowing the addition o hydronicwater or hydronic steam heat to cooling and heating unitsThe kits eature lef- or right-hand piping Unit retainscomplete service access with a kit installed Unit must beconnected to and operated by a wall thermostat

Hydronic Heat Kit Top View

Hydronic Heat Kit Right View

M983151983140983141983148 H983141983137983156 S983156983137983143983141983155 C983151983151983148 S983156983137983143983141983155 F983137983150 S983152983141983141983140 983151983142 W983145983154983141983155R983141983153983157983145983154983141983140

T983141983149983152L983145983149983145983156983145983150983143

B983137983139983147983148983145983156 D983145983155983152983148983137983161 T983161983152983141S983144983137983152983141 983078

O983154983145983141983150983156983137983156983145983151983150C983151983150983150983141983139983156983145983151983150

2246002 1 1 1 5 No Yes Digital Manual RectHoriz Wired

2246003 2 2 2 7 Yes Yes Digital Manual RectHoriz Wired

2246007 2 2 1 7 Yes Yes Digital Auto-Change RectHoriz Wired

2246008 2 2 1 7 Yes Yes Digital Programmable RectHoriz Wired

DS01E 2 2 2 0 Yes Yes Digital Manual RectHoriz Wireless

Battery powered but has optional hard wire capability Requires DT01G Antennae or operation

Hydronic Heat KitSide View

8182019 mc-dptac

httpslidepdfcomreaderfullmc-dptac 1520

15Specifications and Accessories Catalog

Accessories (cont)P983151983159983141983154 D983151983151983154 K983145983156Vent door will automatically open when unit an is on

Factory Installed Feature Code - D

H983161983140983154983151983150983145983139 V983137983148983158983141983155Water and steam valves are available or use with theHWK03 (water) and HVK03 (steam) heat kits

W983145983154983141983148983141983155983155 RF (R983137983140983145983151 F983154983141983153983157983141983150983139983161) C983151983150983156983154983151983148983155All DigiSmart PTACs come actory-ready to be con-trolledvia wireless RF devices 24 Ghz 802 154 protocol assuresrobust communications and response

W983137983148983148 S983148983141983141983158983141 E983160983156983141983150983155983145983151983150 A983140983137983152983156983141983154 K983145983156983155Room-side extension kits to increase the depth o theexisting sleeve to allow or an industry-standard PTAC tobe installed

C983157983154983156983137983145983150 B983137983142983142983148983141 K983145983156The color matched polymer curtain baffles help toprevent curtains rom alling into the discharge airstream and causing recirculation reducing efficienciesand shortening compressor lie

PDK3A 230208V ndash R-22

PDK4A 265V ndash R-22

PDK3E 230208V ndash R-410A

PDK4E 265V ndash R-410A

VS2WNCA 2-way24VNCSteam VS2WNOA 2-way24VNOSteam VW2WNCA 2-way24VNCEnd Switch

VW2WNOA 2-way24VNOEnd Switch VW3WNC2B 3-way24VNCNOEnd Switch

Poptop Actuator

DS01EThermostat 2-way2 Communications

DD01EOccupancy SensorEMS Activation2

DT01GAntenna RouterFactory InstalledFeature Code - R

GT01GGeneric RadioAntenna Router3

DD01F Door Switch EMS Activation2

DP01G Web-enabled Platorm Server

DL01GWeb-enabled PlatormServer Link BAC-NET capable

DR01G Mesh Repeater1

DL01G-SERIAL

Serial Repeater1

1 Consult Amana Sales representative priorto purchase

2 Requires DT01G or use3 Requires DS01E or use

SECM1001A 15 Extension or 12frac12 Climate Master Sleeve (10 Pack)

SEZA0501A 25 Extension or 11frac12 Zone Air Sleeve (5 pack)

PTCB10B 10 Pack or R-22 units

PTCB10E 10 Pack or R-410A units

8182019 mc-dptac

httpslidepdfcomreaderfullmc-dptac 1620

16 wwwamana-ptaccom

Unit with Accessory Wall Sleeve and Sub-base Accessory

3

11

6- 18 9- 91624 -5 16

40

42

Location of external drain holes on bottom flange of Wall Sleeve

3 Clearance

to side walls

Air Flow

Air Flow

Air Flow

Air Discharge Grille ControlDoor

T983151983152 V983145983141983159

F983154983151983150983156 V98314598314198315958 LCDI CORD SET mdash 230V208V UNIT

58 CORD SET 230V208V UNIT

18 CORD SET 2 65V UNIT

3-14

MIN

2

MAX

2-58

42

16-116

RI GHTLEFT

1 and frac34 Concentric knock-outs back ampbottom o sub-base (electrical only)

R983145983143983144983156 V983145983141983159

2frac34

4

11⅜

983225983219 frasl ₁₆

983225983219 frasl ₁₆ 1⅜

16983225 frasl ₁₆

1⅜Arch Grille

⅞Stamped Grille

14⅛Wall Sleeve

21frac12

7⅜

Optional

Sub-base

HingedControlDoor

15deg

40deg

Air discharge grille is reversible to provideeither 15deg or 40deg discharge angle

frac12 ODCopperDrain Tube

8182019 mc-dptac

httpslidepdfcomreaderfullmc-dptac 1720

17Specifications and Accessories Catalog

Framing or Accessory Wall Sleeve (WS9XX)F983137983155983156983141983150983145983150983143 W983137983148983148 S983148983141983141983158983141When installed in an opening the Wall Sleeve must behorizontally level (side-to-side) and pitched frac14 bubble to the outside

(NOTE To ensure unitrsquos maximum efficiency DO NOT over- or under-pitch)

I983150983155983156983137983148983148983137983156983145983151983150 N9831519831569831419831551 I Sub-base (PTSBE) is installed allow minimum

3frac14 height clearance and maximum 5 heightclearance between wall sleeve and loor allowminimum 2frac34 protrusion rom a inished wallSee Note 4 if using hydronic units

2 Drain Kit (DK900D) shipped separately Can bemounted either right side lef side or bottom osleeve I mounted to bottom o sleeve allow2 height clearance rom loor to bottom o sleeve

3 For UL approval 265V units must use Amanareg brandSub-base (PTSBE) or Amanareg brand Hard WireKit (PSHW04A) Overcurrent protection on 265V unitsmust be by cartridge-style time delay uses whichare included and factory-installed on the Amanareg brand 265V chassis

4 I Hydronic Kit (HWK03 or HVK03) is installedWall Sleeve must extend exactly 3 into the roomrom the inished interior wall I using the Amana reg brand Sub-base (PTSBE) only the minimum3frac14 height clearance between wall sleeve and loor

is permissible Unit must also be operated with aremote-mounted thermostat

5 I Duct Kit (MDK) is installed allow a minimum o2⅜ into the room rom the inished interior wall

MountingHoles(Drilled byInstaller)

PlasticAnchor

Screws

ExpansionAnchor Bolt

Toggle Bolt

Wood Screw

AlternativeFastening Method(Field Supplied)

Wall Sleeve must extend a minimum o frac14 beyond outside wall to allow orproper caulking

FINISHED FLOOR

4 2 1 4

16 14

MIN

MAIN STUD

JACK STUDS

HEADER - 4 x 4 OR

DOUBLE 2x 4 ON EDGE

SUB-FLOOR

CRIPPLE

JACK STUD

ADJUST FRAMING TO

SECURE THIS DIMENSION

Wall sleeve opening height should be squared withwall sleeve opening width

H = 16frac14

W = 42frac14

8182019 mc-dptac

httpslidepdfcomreaderfullmc-dptac 1820

Notes

8182019 mc-dptac

httpslidepdfcomreaderfullmc-dptac 1920

Our continuing commitment to quality products may mean a change in speciications without noticecopy 2015 Goodman Company LP Amana is a registered trademark o Maytag Corporation or its related

companies and is used under license to Goodman Company LP Houston TX USA All rights reserved

Quiet two-an motor system

Energy-eicient perormance

DigiSmartreg wireless controls on select models

Wise DecisionItrsquos an Amanareg brand

8182019 mc-dptac

httpslidepdfcomreaderfullmc-dptac 2020

Our continuing commitment to quality products may mean a change in speciications without notice copy 2015 Goodman Company LPAmana is a registered trademark o Maytag Corporation or its related companies and is used under license to Goodman Company L P

wwwamana-ptaccom

Call your Amana brand PTAC sales representative at 800-647-2982 or complete details

Beore purchasing this appliance read important inormation about its estimated annual energy

consumption yearly operating cost or energy efficiency rating that is available rom your retailer

A legacy o comortThe impeccable reputation oan American original

Amana heating and cooling systems are a part of the

enduring legacy of one of Americarsquos most recognized

and respected brands Originating eight decades ago in

Amana Iowa the brand is synonymous with long-last-

ing premium-quality products mdash from home appliances

to heating and air conditioning equipment Chances

are you and generations beore you have enjoyed the

dependable performance and longevity the Amana

brand continues to deliver

MC-DPTAC 07-15Supersedes 06-15

Page 6: mc-dptac

8182019 mc-dptac

httpslidepdfcomreaderfullmc-dptac 620

6 wwwamana-ptaccom

Nomenclature

123 45 6 7 89 1415

Basic Model Type Engineering

PTC Standard Cooler PTAC Major amp Minor Revisions

PTH Standard Heat Pump PTHP

DRY Dehumid Cooler PTAC Features Code

PMC DigiAIR Cooler PTAC A Standard Model

PMH DigiAIR Heat Pump PTAC C Corrosion Protection (Seacoast)

D Power Door

Nominal Cooling Capacity F Fuse Holder (230208 Only)

07 7000 BTUh 60 Hz L Lighting Control

09 9000 BTUh 60 Hz H Hydronic Heat-Capable

10 10000 BTUh 50 Hz P Condensate Pump (PTH Only)

12 12000 BTUh 50 or 60 Hz Q Quiet STC 31 Chassis

15 15000 BTUh 60 Hz R RF Antenna

17 17000 BTUh 60 Hz V Power Vent

X placeholder

Rated Voltage W Hard-Wired (PTQC)

2 115V 60 Hz 1 Phase

3 230208V 60 Hz 1 Phase Heater Size

4 265V 60 Hz 1 Phase 00 No Electric Heat 35 35 kW (230208V)

5 240220V 50 Hz 1 Phase Export 15 15 kW 37 kW (265V)

25 25 kW 50 50 kW

Design Series

G R-410A Use up to 4 as needed in alphabetical order Examples

PTC12350AXXX PTC07335CRXX

PTC12350CXXX PTC07325CQRW

AXXX AA

10111213

PTC 07 3 G 35

Power Cord Configuration

Power Receptacle Configuration

NEMA6-15R 250V

receptacle used on

230208V units

NEMA6-20R 250V

receptacle used on

230208V units

NEMA6-30R 250V

receptacle used on

230208V units

NEMA7-20R 277V receptacle

used on 265V units

NEMA7-30R 277V receptacle

used on 265V units

G

W

20 amp

G W

30 amp

15 amp 20 amp 30 amp

277V Rating Power Cord Plugs

NEMA 7 Configuration

250V Rating Power Cord Plugs with LCDI Device

NEMA 6 Configuration

Power Cord Plugs

All units come with factor-installed power cords

All units less than 250 volts come with LCDI device

8182019 mc-dptac

httpslidepdfcomreaderfullmc-dptac 720

7Specifications and Accessories Catalog

Product Speciications PTC Models mdash CoolingElectric Heat230208 Volts

Model 983094 983096 983097PTC

073GXXXPTC

093GXXXPTC

123GXXXPTC

153GXXXPTC

173GXXX

Voltage 983219 230 208 230 208 230 208 230 208 230 208Capacity (BTUh) 7700 7700 9000 9000 12000 11700 15000 14700 16400 16200Amps 983225⁰ 35 35 41 41 56 56 70 70 84Watts 983225⁰ 658 658 796 783 1114 1085 1500 1470 1740 1720EER 117 117 113 115 104 105 100 100 94

Unit without Electric Heater

Min Circuit Amps 983090 983092 983089983088 42 49 68 85 102

CFM (CoolWet Coil)High 290 290 290 340 340Low 264 264 264 314 314

CFM (Dry Coil)

High 310 310 310 360 360

Low 282 282 282 332 332Ventilated Air CFM (Fan Only) 65 65 65 65 65Dehumidification (PintsHr) 17 22 36 44 48Net Weight (lbs) 98 102 102 113 113Ship Weight (lbs) 113 117 119 130 130

265277 Volts

Model 983089 983094 983096PTC

074GXXXPTC

094GXXXPTC

124GXXXPTC

154GXXX

Voltage 983225 983219 265 265 265 265Capacity (BTUh) 7700 9000 12000 14800Amps 983225⁰ 30 36 48 60Watts 983225⁰ 658 796 1154 1480EER 117 113 104 100

Unit without Electric Heater

Min Circuit Amps 983090 983092983089983088 36 44 59 74

CFM (CoolWet Coil)High 290 290 290 340Low 264 264 264 314

CFM (Dry Coil)High 310 310 310 360Low 282 282 282 332

Ventilated Air CFM (Fan Only) 65 65 65 65Dehumidification (PintsHr) 17 22 36 44Net Weight (lbs) 98 102 102 113Ship Weight (lbs) 113 117 119 130

Actual vent CFM perormance will vary due to application and installation conditions

N983151983156983141983155983225 All 265-volt models must use an Amanareg brand sub-base (PTSB4E) or an Amanareg brand hard-wire kit PTPWHWK4 and

disconnect switch PSHW04A

983218 Minimum Circuit Ampacity (MCA) ratings conorm to the National Electric Code however local codes should apply

983219 Minimum voltage on 230208-volt models is 197 volts maximum is 253 volts Minimum voltage on 265-volt models is 239 volts

maximum is 292 volts⁴ Overcurrent protection or all units without electric heaters is 15 amps Overcurrent protection on 265-volt models must be

cartridge-style time-delay uses (included and actory-installed on all Amana reg brand 265-volt chassis) See heater perormance

⁵ Heating capacity and efficiency based on unit operation without condensate pump unit automatically switches to electricheat at approximately 24degF outdoor ambient

⁶ Speciy two-digit heater kW size to complete model number

⁷ R-410A rerigerant used in all systems

⁸ All units meet or exceed ASHRAE 901 standards

⁹ All units less than 250 volts have a Leak Current Detector Interrupter (LCDI) power cord and meet UL 484 standards

983225⁰ Reer to electric heat perormance data or total MCA and recommended overcurrent protection Amps and Watts notationreers to compressor only

8182019 mc-dptac

httpslidepdfcomreaderfullmc-dptac 820

8 wwwamana-ptaccom

Product Speciications PTH Models mdash CoolingHeat PumpElectric HeatM983151983140983141983148 983089 983094 983096 983097

PTH073GAXXX

PTH093GAXXX

PTH123GAXXX

PTH153GAXXX

PTH074GAXXX

PTH094GAXXX

PTH124GAXXX

PTH154GAXXX

Voltage 983225 983219 230 208 230 208 230 208 230 208 265 265 265 265

Capacity (BTUh) 7600 7600 9000 900012000 12000

14700 14700

7600 9100 12000 14600

Amps 983225⁰ 39 39 42 42 58 58 70 70 31 37 50 61

Watts 983225⁰ 650 633 750 750 1090 1090 1515 1515 650 758 1091 1505

EER 117 120 120120 110110 97 97 117 120 110 97

U983150983145983156 983159983145983156983144983151983157983156 E983148983141983139983156983154983145983139 H983141983137983156983141983154

Min Circuit Amps 983090 983092983089983088 47 51 71 85 38 45 61 74

CFM (CoolWet Coil) High 340 330 340 390 340 330 340 390Low 245 245 245 340 245 245 245 340

CFM (Dry Coil)High 370 360 370 410 370 360 370 410

Low 270 270 270 370 270 270 270 370

Ventilated Air CFM (Fan Only) 65 65 65 65 65 65 65 65

Dehumidiication (PintsHr) 17 22 36 44 17 22 36 44

Net Weight (lbs) 108 112 115 126 108 112 115 125

Ship Weight (lbs) 123 127 132 143 123 127 132 142

Actual vent CFM perormance will vary due to application and installation conditions

N983151983156983141983155983225 All 265-volt models must use an Amanareg brand sub-base (PTSB4E) or an Amanareg brand hard-wire kit (PTPWHWK4)983218 Minimum Circuit Ampacity (MCA) ratings conorm to the National Electric Code however local codes should apply

Minimum voltage on 230208-volt models is 197 volts maximum is 253 volts983219 Minimum voltage on 265-volt models is 239 volts maximum is 292 volts⁴ Overcurrent protection or all units without electric heaters is 15 amps Overcurrent protection on 265-volt models must be

cartridge-style time-delay uses (included and actory-installed on all Amanareg brand 265-volt chassis)⁵ Heating capacity and efficiency based on unit operation without condensate pump unit automatically switches to electric

heat at approximately 24degF outdoor ambient⁶ Speciy two-digit heater kW size to complete model number⁷ R-410A rerigerant used in all systems⁸ All units meet or exceed ASHRAE 901 standards⁹ All units less than 250 volts have a Leak Current Detector Interrupter (LCDI) power cord and meet UL 484 standards983225⁰ Reer to electric heat perormance data or total MCA and recommended overcurrent protection Amps and Watts notation

reers to compressor only

8182019 mc-dptac

httpslidepdfcomreaderfullmc-dptac 920

9Specifications and Accessories Catalog

Actual vent CFM perormance will vary due to application and installation conditions

N983151983156983141983155983225 Minimum Circuit Ampacity (MCA) ratings conorm to the National Electric Code however local codes should apply983090 Minimum voltage on 115-volt models is 109 volts maximum is 127 volts983091 Overcurrent protection or all units without electric heaters is 15 amps⁴ R-410A rerigerant used in all systems

⁵ All units meet or exceed ASHRAE 901 standards⁶ All units less than 250 volts have a Leak Current Detector Interrupter (LCDI) power cord and meet UL 484 standards

M983151983140983141983148 983093 983094PTC

072GXXXPTC

092GXXX

Voltage 983090 115 115

Capacity (BTUh) 7000 9000

Amps 69 83

Watts 585 795

EER 119 113

Min Circuit Amps 983089 983091 83 101

CFM (CoolWet Coil)High 290 290

Low 264 264

CFM (Dry Coil)High 310 310

Low 282 282

Ventilated Air (Fan Only) 65 65

Dehumidiication (PintsHr) 17 23

Net Weight (lbs) 98 102

Ship Weight (lbs) 113 117

Product Speciications PTC 115-Volt Models mdashCoolingHydronic Heat or No-Heat Models

8182019 mc-dptac

httpslidepdfcomreaderfullmc-dptac 1020

10 wwwamana-ptaccom

Product Speciications PTH Models mdash Reverse-Cycle Heating PerormanceH983141983137983156983145983150983143

C983137983152983137983139983145983156983161983225PTH073G

AXXXPTH093G

AXXXPTH123G

AXXXPTH153G

AXXXPTH074G

AXXXPTH094G

AXXXPTH124G

AXXXPTH154G

AXXX

Voltage 983225 983219 230 208 230 208 230 208 230 208 265 265 265 265

BTUh ⁵ 6800 6800 8300 8100 11500 11300 13800 13600 6800 8300 11400 13700

Amps 983225⁰ 39 39 42 42 58 58 70 70 31 37 50 61

Watts 983225⁰ 585 585 715 700 1085 1035 1350 1330 585 715 1080 1340

COP ⁵ 34 34 34 34 31 32 30 30 34 34 31 30

CFM (Dry) 370 360 370 410 370 360 370 410

COP = Coefficiency o Perormance per AHRI Test Procedures units are rated or capacities and efficiencies

N983151983156983141983155

983225 All 265-volt models must use an Amanareg brand sub-base (PTSB4E) or an Amanareg brand hard-wire kit (PTPWHWK4)983218 Minimum branch circuit ampacity ratings conorm to the National Electric Code however local codes should apply983219 Minimum voltage on 230208-volt models is 197 volts maximum is 253 volts

Minimum voltage on 265-volt models is 239 volts maximum is 292 volts⁴ Overcurrent protection or all units without electric heaters is 15 amps Overcurrent protection on 265-volt models must

be cartridge-style time-delay uses (included and actory-installed on all Amanareg brand 265-volt chassis)⁵ Heating capacity and efficiency based on unit operation without condensate pump unit automatically switches to electric

heat at approximately 24degF outdoor ambient⁶ Speciy two-digit heater kW size to complete model number⁷ R-410A rerigerant used in all systems⁸ All units meet or exceed ASHRAE 901 standards⁹ All units less than 250 volts have a Leak Current Detector Interrupter (LCDI) power cord and meet UL 484 standards983225⁰ Reer to electric heat perormance data or total MCA and recommended overcurrent protection

Amps and Watts notation reers to compressor only

Product Speciications PTC PTH Models mdash Electric Heat Perormance(Primary Heating or PTC Models Auxiliary Heating or PTH Models See below or Power Cord Coniguration)

V983151983148983156983137983143983141E983148983141983139983156983154983145983139H983141983137983156983141983154

S983145983162983141 (983147W)

N983151 983151983142S983156983137983143983141983155

N983151983149983145983150983137983148 H983141983137983156983145983150983143 (BTU983144)T983151983156983137983148

W983137983156983156983155983094T983151983156983137983148 A983149983152983155

M983145983150 C983145983154983139983157983145983156 A983149983152983137983139983145983156983161983218

MOP983092(983137983149983152983155)

P983151983159983141983154C983151983154983140

10486269830911048624V 104862610486241048632V 104862610486301048629V

230208V 15 13 1 5100 4200 - - 1570 1295 68 62 85 15 6-15 P

230208V 25 21 1 8500 6800 - - 2570 2115 112 101 141 15 6-15 P

230208V 35 30 1 12000 9900 - - 3570 2935 155 141 195 20 6-20 P

230208V 50 41 1 17100 14000 - - 5070 4160 221 200 276 30 6-30 P

265V 15 1 - - - - 5100 1570 59 74 15 7-20P

265V 25 1 - - - - 8500 2570 97 122 15 7-20 P

265V 37 1 - - - - 12600 3770 142 179 20 7-20 P265V 5 1 - - - - 17100 5070 192 239 25 7-30 P

N983151983156983141983155983225 All 265-volt models must use an Amanareg brand sub-base (PTSB4E) or an Amanareg brand hard-wire kit (PTPWHWK4)983218 Minimum branch circuit ampacity ratings conorm to the National Electric Code however local codes should apply983219 Minimum voltage on 230208-volt models is 197 volts maximum is 253 volts Minimum voltage on 265-volt models is 239 volts maximum is 292 volts⁴ Overcurrent protection or all units without electric heaters is 15 amps Overcurrent protection on 265-volt models must be cartridge-style

time-delay uses (included and actory-installed on all Amanareg brand 265-volt chassis)⁵ Heating capacity and efficiency based on unit operation without condensate pump unit automatically switches to electric heat at

approximately 24degF outdoor ambient⁶ Total watts or 15000 BTUh models subtract 20 watts or PT070912⁷ Speciy two-digit heater kW size to complete model number⁸ R-410A rerigerant used in all systems⁹ All units meet or exceed ASHRAE 901 standards983225⁰ All units less than 250 volts have a Leak Current Detector Interrupter (LCDI) power cord and meet UL 484 standards

8182019 mc-dptac

httpslidepdfcomreaderfullmc-dptac 1120

11Specifications and Accessories Catalog

AccessoriesW983137983148983148 S983148983141983141983158983141983155All our wall sleeves have industry standard dimensionso 42 wide x 16⅟ ₁₆ high The WS900E SC and INTERNAL14⅛ depth is the industry standard Sleeves maybe shipped separately to allow or installationduring construction

C983151983150983140983141983150983155983137983156983141 D983154983137983145983150 K983145983156Attaches to the wall sleeve base pan or controlledinternal or external disposal o condensate

L983151983159983085V983151983148983156983137983143983141 W983145983154983141 H983137983154983150983141983155983155 K983145983156 (983150983151983156 983155983144983151983159983150)For quick connections o the remote or wiredthermostats wired EMS or ront desk with jumpers andconnectors

R983141983149983151983156983141 E983155983139983157983156983139983144983141983151983150 K983145983156 (983150983151983156 983155983144983151983159983150)Optional kit or use with units controlled via a wiredremote thermostat Covers control touch-pad or wiredthermostat installations

Each ldquoBrdquo kit contains 80 wires and wire nutsenough to attach a thermostat and oneadditional accessory to 10 PTAC units Wirescome in assorted colors or easy attachmentEach ldquoArdquo kit contains 10 Escutcheon plates only

O983157983156983140983151983151983154 G983154983145983148983148983141983155Available in stamped-aluminum or architecturallylouvered or application with an Amana brand WS900Ewall sleeve

AGK Extruded aluminum architectural grille availablewith anodized aluminum inish or a baked-on paintinish or durability Choose rom 3 stock colors or acustom color to blend with your buildingrsquos exteriorcolor scheme Colors include

CB (Clear Anodized) DB (Dark BrownBronze)TB (Stonewood Beige) WB (White)SB (SpecialCustom Colors)

PGK One-piece injection molded grille using a polymerblend o engineered thermoplastic high-impactstrength material with chemical resistance andan exterior UV protective coating

Choose from 3 stock colorsDB (Dark BrownBronze) TB (Stonewood Beige)

WB (White)

S983156983137983150983140983137983154983140983085D983141983152983156983144 S983148983141983141983158983141983155

WS900E-GS Heavy Sound Isolation Insulation Sleeve

WS900E Standard PTAC sleeve

WS900SC Seacoast triple protected

WS900D-INTERNAL

Internal drain only or window-wallinstallations (DK900D sold separately)

E983160983156983154983137 D983141983141983152 S983148983141983141983158983141983155 in several depths orthicker wall installations or special roomconigurations

WS9XXD1 16 to 24 in 1 increments

WS928D1 Extra deep 28

WS930D1 Extra deep 30

WS936D1 Extra deep 36

WS9XXD1-Interna

Extra deep Internal drain onlyor window-wall installations(DK900D sold separately) 1 4

⅛ 4 2

1 6

1

1 6

S983156983137983150983140983137983154983140 O983157983156983140983151983151983154 G983154983145983148983148983141

SGK01B Single Pack

SGK01TB Stonewood Beige

A983154983139983144983145983156983141983139983156983157983154983137983148 O983157983156983140983151983151983154 G983154983145983148983148983141

AGK01CB Anodized Aluminum

AGK01DB Dark BronzeBrown

AGK01TB Stonewood Beige

AGK01WB Amana White

AGK01SB Custom Colors

PGK01DB Dark BronzeBrown

PGK01TB Stonewood Beige

PGK01WB Amana White

AGKor

PGK

SGK

DK900DCondensate Drain Kit(use with WS900E)

DK9001DCondensate Drain Kit(use with WS900B)

DK900D

PWHK01C Wire Harness Kit

REK10BRemote Escutcheon Kit(10-pack)

REK10A Remote Escutcheon Plates

8182019 mc-dptac

httpslidepdfcomreaderfullmc-dptac 1220

12 wwwamana-ptaccom

Accessories (cont)S983157983138983085983138983137983155983141 K983145983156The ully skirted sub-base conceals wiring whileproviding strong support i needed Plug-in receptacleand ield-wiring access speeds installation Electricalaccessories such as use holders circuit breakers anddisconnect switches meet NEC requirements

L983141983158983141983148983145983150983143 L983141983143983155Gives wall sleeve ront support and helps to level theunit or installation

H983137983154983140983085983159983145983154983141 K983145983156983155Used to permanently wire to the chassis when astandard sub-base and power cord are not utilized

F983137983139983156983151983154983161 I983150983155983156983137983148983148983141983140 Feature Code - W

P983151983159983141983154 D983145983155983139983151983150983150983141983139983156 S983159983145983156983139983144The PSHWA power disconnect switch can be usedor 265-volt or 230208-volt physical disconnectwhere required by local codes The switch is ratedat 30-amp capacity The switch is or use with andAmanareg brand standard sub-bases or PTPWHWK4Hard Wire Kit

F983157983155983141 H983151983148983140983141983154 K983145983156Cartridge-style uses can be installed in the useholder or use in the sub-base or chassis Available in15 20 and 30 amp (included on 265-volt unit)

C983145983154983139983157983145983156 B983154983141983137983147983141983154 K983145983156 (983090983091983088983090983088983096V 983151983150983148983161)The circuit breaker kit available in 15 20 or 30 ampcan be used with Amana brand sub-bases It givesovercurrent protection and its location allows you toturn the unit on or off without tools

PTSB215E 115V15A

PTSB320E 230208V 1520A

PTSB330E 230208V 30A

PTSB420E 265V 1520A

PTSB430E 265V 25A

PTSB000E Non-electrical

LL2B Leveling legs or WS9 sleeves

PTPWHWK4 Armored Cable ndash all voltages

PTQC3A Quick Connect ndash 230208V

PTQC4A Quick Connect ndash 265 amp 115 V

PSHW03A 230208V

PSHW04A 265V

FHK315E 230208V 15A

FHK315E 230208V 15A (R-410A)

FHK320C 230208V 20A

FHK320E 230208V 20A (R-410A)

FHK330C 230208V 30A

FHK330E 230208V 30A (R-410A)

CBK15C 15 amp Circuit Breaker Kit

CBK20C 20 amp Circuit Breaker Kit

CBK30C 30 amp Circuit Breaker Kit

8182019 mc-dptac

httpslidepdfcomreaderfullmc-dptac 1320

13Specifications and Accessories Catalog

Accessories (cont)

P983151983159983141983154 V983141983150983156 K983145983156Installation o Power Vent increases CFM up toapproximately 95 Vent door will automatically closewhen unit an is off

F983137983139983156983151983154983161 I983150983155983156983137983148983148983141983140 Feature Code - VR-410A models must have these kits installed atthe actory

C983151983150983140983141983150983155983141983154 B983137983142983142983148983141 K983145983156For use on non-baffled grilles These delectors directthe air in toward the center and away rom the inlet toprevent recirculation o the hot condenser air

S983157983138983085983138983137983155983141 E983160983156983141983150983155983145983151983150 C983151983158983141983154 K983145983156Converts older 30-amp sub-bases to allow or installationo the larger 30-amp LCDI power cord and plugs

S983141983139983157983154983145983156983161 K983141983161 L983151983139983147983155In conjunction with the tamper-resistant ront theinstallation o Amanareg brand security key locks preventstampering o the controls used to set temperature heatingand cooling unctions UL approved or institutionaluse only

C983151983150983140983141983150983155983137983156983141 R983141983149983151983158983137983148 P983157983149983152Can be ield-installed Assists in removing condensatedeveloped by heat pump operation and transers it to

indoor coil to dissipate into room while adding humidityto the room

F983137983139983156983151983154983161 I983150983155983156983137983148983148983141983140 Feature Code - P

PVK3A 230208V ndash R-22

PVK4A 265V ndash R-22

D983157983139983156 E983160983156983141983150983155983145983151983150 K983145983156Extends air distribution to an adjoining room Consistsof a main duct for the room of origin and an extensionduct to reach the adjoining room and terminal ductPTDK01A allows for the ldquoBrdquo series unit to work with theldquoArdquo series duct kits

MDK02B Main Duct ndash R-22

MDK01E Main Duct ndash R-410A

EDK02B 42 Extension Duct

TRANSITION BAFFLES

Main Duct Kit

TDK02B Terminal Duct

PTDK01A Transition Duct Only ndash R-22

PTDK01E Transition Duct Only ndash R-410A

Extension Duct Kit

Terminal Duct Kit

DGK1B Condenser Baffle Kit

SBEC10A 10 Pack

Basepan

Condenser

Condenser Baffles

KL03B Security Key Lock (R-22)

KL03E Security Key Lock (R-410A)

CDP302 230208V ndash R-22

CDP402 265V ndash R-22

CDP303E 230208V ndash R-410A

8182019 mc-dptac

httpslidepdfcomreaderfullmc-dptac 1420

14 wwwamana-ptaccom

Accessories (cont)

HWK03B Hydronic Water Kit ndash R-22

HVK03B Hydronic Steam Kit ndash R-22

HWK03E Hydronic Water Kit ndash R-410A

HVK03E Hydronic Steam Kit ndash R-410A

ThermostatsThe ollowing thermostats offer remote control Any thermostat other than those listed must be submitted to Goodman Company LPor approval prior to use

H983161983140983154983151983150983145983139 H983141983137983156 K983145983156Add-on kits it all units allowing the addition o hydronicwater or hydronic steam heat to cooling and heating unitsThe kits eature lef- or right-hand piping Unit retainscomplete service access with a kit installed Unit must beconnected to and operated by a wall thermostat

Hydronic Heat Kit Top View

Hydronic Heat Kit Right View

M983151983140983141983148 H983141983137983156 S983156983137983143983141983155 C983151983151983148 S983156983137983143983141983155 F983137983150 S983152983141983141983140 983151983142 W983145983154983141983155R983141983153983157983145983154983141983140

T983141983149983152L983145983149983145983156983145983150983143

B983137983139983147983148983145983156 D983145983155983152983148983137983161 T983161983152983141S983144983137983152983141 983078

O983154983145983141983150983156983137983156983145983151983150C983151983150983150983141983139983156983145983151983150

2246002 1 1 1 5 No Yes Digital Manual RectHoriz Wired

2246003 2 2 2 7 Yes Yes Digital Manual RectHoriz Wired

2246007 2 2 1 7 Yes Yes Digital Auto-Change RectHoriz Wired

2246008 2 2 1 7 Yes Yes Digital Programmable RectHoriz Wired

DS01E 2 2 2 0 Yes Yes Digital Manual RectHoriz Wireless

Battery powered but has optional hard wire capability Requires DT01G Antennae or operation

Hydronic Heat KitSide View

8182019 mc-dptac

httpslidepdfcomreaderfullmc-dptac 1520

15Specifications and Accessories Catalog

Accessories (cont)P983151983159983141983154 D983151983151983154 K983145983156Vent door will automatically open when unit an is on

Factory Installed Feature Code - D

H983161983140983154983151983150983145983139 V983137983148983158983141983155Water and steam valves are available or use with theHWK03 (water) and HVK03 (steam) heat kits

W983145983154983141983148983141983155983155 RF (R983137983140983145983151 F983154983141983153983157983141983150983139983161) C983151983150983156983154983151983148983155All DigiSmart PTACs come actory-ready to be con-trolledvia wireless RF devices 24 Ghz 802 154 protocol assuresrobust communications and response

W983137983148983148 S983148983141983141983158983141 E983160983156983141983150983155983145983151983150 A983140983137983152983156983141983154 K983145983156983155Room-side extension kits to increase the depth o theexisting sleeve to allow or an industry-standard PTAC tobe installed

C983157983154983156983137983145983150 B983137983142983142983148983141 K983145983156The color matched polymer curtain baffles help toprevent curtains rom alling into the discharge airstream and causing recirculation reducing efficienciesand shortening compressor lie

PDK3A 230208V ndash R-22

PDK4A 265V ndash R-22

PDK3E 230208V ndash R-410A

PDK4E 265V ndash R-410A

VS2WNCA 2-way24VNCSteam VS2WNOA 2-way24VNOSteam VW2WNCA 2-way24VNCEnd Switch

VW2WNOA 2-way24VNOEnd Switch VW3WNC2B 3-way24VNCNOEnd Switch

Poptop Actuator

DS01EThermostat 2-way2 Communications

DD01EOccupancy SensorEMS Activation2

DT01GAntenna RouterFactory InstalledFeature Code - R

GT01GGeneric RadioAntenna Router3

DD01F Door Switch EMS Activation2

DP01G Web-enabled Platorm Server

DL01GWeb-enabled PlatormServer Link BAC-NET capable

DR01G Mesh Repeater1

DL01G-SERIAL

Serial Repeater1

1 Consult Amana Sales representative priorto purchase

2 Requires DT01G or use3 Requires DS01E or use

SECM1001A 15 Extension or 12frac12 Climate Master Sleeve (10 Pack)

SEZA0501A 25 Extension or 11frac12 Zone Air Sleeve (5 pack)

PTCB10B 10 Pack or R-22 units

PTCB10E 10 Pack or R-410A units

8182019 mc-dptac

httpslidepdfcomreaderfullmc-dptac 1620

16 wwwamana-ptaccom

Unit with Accessory Wall Sleeve and Sub-base Accessory

3

11

6- 18 9- 91624 -5 16

40

42

Location of external drain holes on bottom flange of Wall Sleeve

3 Clearance

to side walls

Air Flow

Air Flow

Air Flow

Air Discharge Grille ControlDoor

T983151983152 V983145983141983159

F983154983151983150983156 V98314598314198315958 LCDI CORD SET mdash 230V208V UNIT

58 CORD SET 230V208V UNIT

18 CORD SET 2 65V UNIT

3-14

MIN

2

MAX

2-58

42

16-116

RI GHTLEFT

1 and frac34 Concentric knock-outs back ampbottom o sub-base (electrical only)

R983145983143983144983156 V983145983141983159

2frac34

4

11⅜

983225983219 frasl ₁₆

983225983219 frasl ₁₆ 1⅜

16983225 frasl ₁₆

1⅜Arch Grille

⅞Stamped Grille

14⅛Wall Sleeve

21frac12

7⅜

Optional

Sub-base

HingedControlDoor

15deg

40deg

Air discharge grille is reversible to provideeither 15deg or 40deg discharge angle

frac12 ODCopperDrain Tube

8182019 mc-dptac

httpslidepdfcomreaderfullmc-dptac 1720

17Specifications and Accessories Catalog

Framing or Accessory Wall Sleeve (WS9XX)F983137983155983156983141983150983145983150983143 W983137983148983148 S983148983141983141983158983141When installed in an opening the Wall Sleeve must behorizontally level (side-to-side) and pitched frac14 bubble to the outside

(NOTE To ensure unitrsquos maximum efficiency DO NOT over- or under-pitch)

I983150983155983156983137983148983148983137983156983145983151983150 N9831519831569831419831551 I Sub-base (PTSBE) is installed allow minimum

3frac14 height clearance and maximum 5 heightclearance between wall sleeve and loor allowminimum 2frac34 protrusion rom a inished wallSee Note 4 if using hydronic units

2 Drain Kit (DK900D) shipped separately Can bemounted either right side lef side or bottom osleeve I mounted to bottom o sleeve allow2 height clearance rom loor to bottom o sleeve

3 For UL approval 265V units must use Amanareg brandSub-base (PTSBE) or Amanareg brand Hard WireKit (PSHW04A) Overcurrent protection on 265V unitsmust be by cartridge-style time delay uses whichare included and factory-installed on the Amanareg brand 265V chassis

4 I Hydronic Kit (HWK03 or HVK03) is installedWall Sleeve must extend exactly 3 into the roomrom the inished interior wall I using the Amana reg brand Sub-base (PTSBE) only the minimum3frac14 height clearance between wall sleeve and loor

is permissible Unit must also be operated with aremote-mounted thermostat

5 I Duct Kit (MDK) is installed allow a minimum o2⅜ into the room rom the inished interior wall

MountingHoles(Drilled byInstaller)

PlasticAnchor

Screws

ExpansionAnchor Bolt

Toggle Bolt

Wood Screw

AlternativeFastening Method(Field Supplied)

Wall Sleeve must extend a minimum o frac14 beyond outside wall to allow orproper caulking

FINISHED FLOOR

4 2 1 4

16 14

MIN

MAIN STUD

JACK STUDS

HEADER - 4 x 4 OR

DOUBLE 2x 4 ON EDGE

SUB-FLOOR

CRIPPLE

JACK STUD

ADJUST FRAMING TO

SECURE THIS DIMENSION

Wall sleeve opening height should be squared withwall sleeve opening width

H = 16frac14

W = 42frac14

8182019 mc-dptac

httpslidepdfcomreaderfullmc-dptac 1820

Notes

8182019 mc-dptac

httpslidepdfcomreaderfullmc-dptac 1920

Our continuing commitment to quality products may mean a change in speciications without noticecopy 2015 Goodman Company LP Amana is a registered trademark o Maytag Corporation or its related

companies and is used under license to Goodman Company LP Houston TX USA All rights reserved

Quiet two-an motor system

Energy-eicient perormance

DigiSmartreg wireless controls on select models

Wise DecisionItrsquos an Amanareg brand

8182019 mc-dptac

httpslidepdfcomreaderfullmc-dptac 2020

Our continuing commitment to quality products may mean a change in speciications without notice copy 2015 Goodman Company LPAmana is a registered trademark o Maytag Corporation or its related companies and is used under license to Goodman Company L P

wwwamana-ptaccom

Call your Amana brand PTAC sales representative at 800-647-2982 or complete details

Beore purchasing this appliance read important inormation about its estimated annual energy

consumption yearly operating cost or energy efficiency rating that is available rom your retailer

A legacy o comortThe impeccable reputation oan American original

Amana heating and cooling systems are a part of the

enduring legacy of one of Americarsquos most recognized

and respected brands Originating eight decades ago in

Amana Iowa the brand is synonymous with long-last-

ing premium-quality products mdash from home appliances

to heating and air conditioning equipment Chances

are you and generations beore you have enjoyed the

dependable performance and longevity the Amana

brand continues to deliver

MC-DPTAC 07-15Supersedes 06-15

Page 7: mc-dptac

8182019 mc-dptac

httpslidepdfcomreaderfullmc-dptac 720

7Specifications and Accessories Catalog

Product Speciications PTC Models mdash CoolingElectric Heat230208 Volts

Model 983094 983096 983097PTC

073GXXXPTC

093GXXXPTC

123GXXXPTC

153GXXXPTC

173GXXX

Voltage 983219 230 208 230 208 230 208 230 208 230 208Capacity (BTUh) 7700 7700 9000 9000 12000 11700 15000 14700 16400 16200Amps 983225⁰ 35 35 41 41 56 56 70 70 84Watts 983225⁰ 658 658 796 783 1114 1085 1500 1470 1740 1720EER 117 117 113 115 104 105 100 100 94

Unit without Electric Heater

Min Circuit Amps 983090 983092 983089983088 42 49 68 85 102

CFM (CoolWet Coil)High 290 290 290 340 340Low 264 264 264 314 314

CFM (Dry Coil)

High 310 310 310 360 360

Low 282 282 282 332 332Ventilated Air CFM (Fan Only) 65 65 65 65 65Dehumidification (PintsHr) 17 22 36 44 48Net Weight (lbs) 98 102 102 113 113Ship Weight (lbs) 113 117 119 130 130

265277 Volts

Model 983089 983094 983096PTC

074GXXXPTC

094GXXXPTC

124GXXXPTC

154GXXX

Voltage 983225 983219 265 265 265 265Capacity (BTUh) 7700 9000 12000 14800Amps 983225⁰ 30 36 48 60Watts 983225⁰ 658 796 1154 1480EER 117 113 104 100

Unit without Electric Heater

Min Circuit Amps 983090 983092983089983088 36 44 59 74

CFM (CoolWet Coil)High 290 290 290 340Low 264 264 264 314

CFM (Dry Coil)High 310 310 310 360Low 282 282 282 332

Ventilated Air CFM (Fan Only) 65 65 65 65Dehumidification (PintsHr) 17 22 36 44Net Weight (lbs) 98 102 102 113Ship Weight (lbs) 113 117 119 130

Actual vent CFM perormance will vary due to application and installation conditions

N983151983156983141983155983225 All 265-volt models must use an Amanareg brand sub-base (PTSB4E) or an Amanareg brand hard-wire kit PTPWHWK4 and

disconnect switch PSHW04A

983218 Minimum Circuit Ampacity (MCA) ratings conorm to the National Electric Code however local codes should apply

983219 Minimum voltage on 230208-volt models is 197 volts maximum is 253 volts Minimum voltage on 265-volt models is 239 volts

maximum is 292 volts⁴ Overcurrent protection or all units without electric heaters is 15 amps Overcurrent protection on 265-volt models must be

cartridge-style time-delay uses (included and actory-installed on all Amana reg brand 265-volt chassis) See heater perormance

⁵ Heating capacity and efficiency based on unit operation without condensate pump unit automatically switches to electricheat at approximately 24degF outdoor ambient

⁶ Speciy two-digit heater kW size to complete model number

⁷ R-410A rerigerant used in all systems

⁸ All units meet or exceed ASHRAE 901 standards

⁹ All units less than 250 volts have a Leak Current Detector Interrupter (LCDI) power cord and meet UL 484 standards

983225⁰ Reer to electric heat perormance data or total MCA and recommended overcurrent protection Amps and Watts notationreers to compressor only

8182019 mc-dptac

httpslidepdfcomreaderfullmc-dptac 820

8 wwwamana-ptaccom

Product Speciications PTH Models mdash CoolingHeat PumpElectric HeatM983151983140983141983148 983089 983094 983096 983097

PTH073GAXXX

PTH093GAXXX

PTH123GAXXX

PTH153GAXXX

PTH074GAXXX

PTH094GAXXX

PTH124GAXXX

PTH154GAXXX

Voltage 983225 983219 230 208 230 208 230 208 230 208 265 265 265 265

Capacity (BTUh) 7600 7600 9000 900012000 12000

14700 14700

7600 9100 12000 14600

Amps 983225⁰ 39 39 42 42 58 58 70 70 31 37 50 61

Watts 983225⁰ 650 633 750 750 1090 1090 1515 1515 650 758 1091 1505

EER 117 120 120120 110110 97 97 117 120 110 97

U983150983145983156 983159983145983156983144983151983157983156 E983148983141983139983156983154983145983139 H983141983137983156983141983154

Min Circuit Amps 983090 983092983089983088 47 51 71 85 38 45 61 74

CFM (CoolWet Coil) High 340 330 340 390 340 330 340 390Low 245 245 245 340 245 245 245 340

CFM (Dry Coil)High 370 360 370 410 370 360 370 410

Low 270 270 270 370 270 270 270 370

Ventilated Air CFM (Fan Only) 65 65 65 65 65 65 65 65

Dehumidiication (PintsHr) 17 22 36 44 17 22 36 44

Net Weight (lbs) 108 112 115 126 108 112 115 125

Ship Weight (lbs) 123 127 132 143 123 127 132 142

Actual vent CFM perormance will vary due to application and installation conditions

N983151983156983141983155983225 All 265-volt models must use an Amanareg brand sub-base (PTSB4E) or an Amanareg brand hard-wire kit (PTPWHWK4)983218 Minimum Circuit Ampacity (MCA) ratings conorm to the National Electric Code however local codes should apply

Minimum voltage on 230208-volt models is 197 volts maximum is 253 volts983219 Minimum voltage on 265-volt models is 239 volts maximum is 292 volts⁴ Overcurrent protection or all units without electric heaters is 15 amps Overcurrent protection on 265-volt models must be

cartridge-style time-delay uses (included and actory-installed on all Amanareg brand 265-volt chassis)⁵ Heating capacity and efficiency based on unit operation without condensate pump unit automatically switches to electric

heat at approximately 24degF outdoor ambient⁶ Speciy two-digit heater kW size to complete model number⁷ R-410A rerigerant used in all systems⁸ All units meet or exceed ASHRAE 901 standards⁹ All units less than 250 volts have a Leak Current Detector Interrupter (LCDI) power cord and meet UL 484 standards983225⁰ Reer to electric heat perormance data or total MCA and recommended overcurrent protection Amps and Watts notation

reers to compressor only

8182019 mc-dptac

httpslidepdfcomreaderfullmc-dptac 920

9Specifications and Accessories Catalog

Actual vent CFM perormance will vary due to application and installation conditions

N983151983156983141983155983225 Minimum Circuit Ampacity (MCA) ratings conorm to the National Electric Code however local codes should apply983090 Minimum voltage on 115-volt models is 109 volts maximum is 127 volts983091 Overcurrent protection or all units without electric heaters is 15 amps⁴ R-410A rerigerant used in all systems

⁵ All units meet or exceed ASHRAE 901 standards⁶ All units less than 250 volts have a Leak Current Detector Interrupter (LCDI) power cord and meet UL 484 standards

M983151983140983141983148 983093 983094PTC

072GXXXPTC

092GXXX

Voltage 983090 115 115

Capacity (BTUh) 7000 9000

Amps 69 83

Watts 585 795

EER 119 113

Min Circuit Amps 983089 983091 83 101

CFM (CoolWet Coil)High 290 290

Low 264 264

CFM (Dry Coil)High 310 310

Low 282 282

Ventilated Air (Fan Only) 65 65

Dehumidiication (PintsHr) 17 23

Net Weight (lbs) 98 102

Ship Weight (lbs) 113 117

Product Speciications PTC 115-Volt Models mdashCoolingHydronic Heat or No-Heat Models

8182019 mc-dptac

httpslidepdfcomreaderfullmc-dptac 1020

10 wwwamana-ptaccom

Product Speciications PTH Models mdash Reverse-Cycle Heating PerormanceH983141983137983156983145983150983143

C983137983152983137983139983145983156983161983225PTH073G

AXXXPTH093G

AXXXPTH123G

AXXXPTH153G

AXXXPTH074G

AXXXPTH094G

AXXXPTH124G

AXXXPTH154G

AXXX

Voltage 983225 983219 230 208 230 208 230 208 230 208 265 265 265 265

BTUh ⁵ 6800 6800 8300 8100 11500 11300 13800 13600 6800 8300 11400 13700

Amps 983225⁰ 39 39 42 42 58 58 70 70 31 37 50 61

Watts 983225⁰ 585 585 715 700 1085 1035 1350 1330 585 715 1080 1340

COP ⁵ 34 34 34 34 31 32 30 30 34 34 31 30

CFM (Dry) 370 360 370 410 370 360 370 410

COP = Coefficiency o Perormance per AHRI Test Procedures units are rated or capacities and efficiencies

N983151983156983141983155

983225 All 265-volt models must use an Amanareg brand sub-base (PTSB4E) or an Amanareg brand hard-wire kit (PTPWHWK4)983218 Minimum branch circuit ampacity ratings conorm to the National Electric Code however local codes should apply983219 Minimum voltage on 230208-volt models is 197 volts maximum is 253 volts

Minimum voltage on 265-volt models is 239 volts maximum is 292 volts⁴ Overcurrent protection or all units without electric heaters is 15 amps Overcurrent protection on 265-volt models must

be cartridge-style time-delay uses (included and actory-installed on all Amanareg brand 265-volt chassis)⁵ Heating capacity and efficiency based on unit operation without condensate pump unit automatically switches to electric

heat at approximately 24degF outdoor ambient⁶ Speciy two-digit heater kW size to complete model number⁷ R-410A rerigerant used in all systems⁸ All units meet or exceed ASHRAE 901 standards⁹ All units less than 250 volts have a Leak Current Detector Interrupter (LCDI) power cord and meet UL 484 standards983225⁰ Reer to electric heat perormance data or total MCA and recommended overcurrent protection

Amps and Watts notation reers to compressor only

Product Speciications PTC PTH Models mdash Electric Heat Perormance(Primary Heating or PTC Models Auxiliary Heating or PTH Models See below or Power Cord Coniguration)

V983151983148983156983137983143983141E983148983141983139983156983154983145983139H983141983137983156983141983154

S983145983162983141 (983147W)

N983151 983151983142S983156983137983143983141983155

N983151983149983145983150983137983148 H983141983137983156983145983150983143 (BTU983144)T983151983156983137983148

W983137983156983156983155983094T983151983156983137983148 A983149983152983155

M983145983150 C983145983154983139983157983145983156 A983149983152983137983139983145983156983161983218

MOP983092(983137983149983152983155)

P983151983159983141983154C983151983154983140

10486269830911048624V 104862610486241048632V 104862610486301048629V

230208V 15 13 1 5100 4200 - - 1570 1295 68 62 85 15 6-15 P

230208V 25 21 1 8500 6800 - - 2570 2115 112 101 141 15 6-15 P

230208V 35 30 1 12000 9900 - - 3570 2935 155 141 195 20 6-20 P

230208V 50 41 1 17100 14000 - - 5070 4160 221 200 276 30 6-30 P

265V 15 1 - - - - 5100 1570 59 74 15 7-20P

265V 25 1 - - - - 8500 2570 97 122 15 7-20 P

265V 37 1 - - - - 12600 3770 142 179 20 7-20 P265V 5 1 - - - - 17100 5070 192 239 25 7-30 P

N983151983156983141983155983225 All 265-volt models must use an Amanareg brand sub-base (PTSB4E) or an Amanareg brand hard-wire kit (PTPWHWK4)983218 Minimum branch circuit ampacity ratings conorm to the National Electric Code however local codes should apply983219 Minimum voltage on 230208-volt models is 197 volts maximum is 253 volts Minimum voltage on 265-volt models is 239 volts maximum is 292 volts⁴ Overcurrent protection or all units without electric heaters is 15 amps Overcurrent protection on 265-volt models must be cartridge-style

time-delay uses (included and actory-installed on all Amanareg brand 265-volt chassis)⁵ Heating capacity and efficiency based on unit operation without condensate pump unit automatically switches to electric heat at

approximately 24degF outdoor ambient⁶ Total watts or 15000 BTUh models subtract 20 watts or PT070912⁷ Speciy two-digit heater kW size to complete model number⁸ R-410A rerigerant used in all systems⁹ All units meet or exceed ASHRAE 901 standards983225⁰ All units less than 250 volts have a Leak Current Detector Interrupter (LCDI) power cord and meet UL 484 standards

8182019 mc-dptac

httpslidepdfcomreaderfullmc-dptac 1120

11Specifications and Accessories Catalog

AccessoriesW983137983148983148 S983148983141983141983158983141983155All our wall sleeves have industry standard dimensionso 42 wide x 16⅟ ₁₆ high The WS900E SC and INTERNAL14⅛ depth is the industry standard Sleeves maybe shipped separately to allow or installationduring construction

C983151983150983140983141983150983155983137983156983141 D983154983137983145983150 K983145983156Attaches to the wall sleeve base pan or controlledinternal or external disposal o condensate

L983151983159983085V983151983148983156983137983143983141 W983145983154983141 H983137983154983150983141983155983155 K983145983156 (983150983151983156 983155983144983151983159983150)For quick connections o the remote or wiredthermostats wired EMS or ront desk with jumpers andconnectors

R983141983149983151983156983141 E983155983139983157983156983139983144983141983151983150 K983145983156 (983150983151983156 983155983144983151983159983150)Optional kit or use with units controlled via a wiredremote thermostat Covers control touch-pad or wiredthermostat installations

Each ldquoBrdquo kit contains 80 wires and wire nutsenough to attach a thermostat and oneadditional accessory to 10 PTAC units Wirescome in assorted colors or easy attachmentEach ldquoArdquo kit contains 10 Escutcheon plates only

O983157983156983140983151983151983154 G983154983145983148983148983141983155Available in stamped-aluminum or architecturallylouvered or application with an Amana brand WS900Ewall sleeve

AGK Extruded aluminum architectural grille availablewith anodized aluminum inish or a baked-on paintinish or durability Choose rom 3 stock colors or acustom color to blend with your buildingrsquos exteriorcolor scheme Colors include

CB (Clear Anodized) DB (Dark BrownBronze)TB (Stonewood Beige) WB (White)SB (SpecialCustom Colors)

PGK One-piece injection molded grille using a polymerblend o engineered thermoplastic high-impactstrength material with chemical resistance andan exterior UV protective coating

Choose from 3 stock colorsDB (Dark BrownBronze) TB (Stonewood Beige)

WB (White)

S983156983137983150983140983137983154983140983085D983141983152983156983144 S983148983141983141983158983141983155

WS900E-GS Heavy Sound Isolation Insulation Sleeve

WS900E Standard PTAC sleeve

WS900SC Seacoast triple protected

WS900D-INTERNAL

Internal drain only or window-wallinstallations (DK900D sold separately)

E983160983156983154983137 D983141983141983152 S983148983141983141983158983141983155 in several depths orthicker wall installations or special roomconigurations

WS9XXD1 16 to 24 in 1 increments

WS928D1 Extra deep 28

WS930D1 Extra deep 30

WS936D1 Extra deep 36

WS9XXD1-Interna

Extra deep Internal drain onlyor window-wall installations(DK900D sold separately) 1 4

⅛ 4 2

1 6

1

1 6

S983156983137983150983140983137983154983140 O983157983156983140983151983151983154 G983154983145983148983148983141

SGK01B Single Pack

SGK01TB Stonewood Beige

A983154983139983144983145983156983141983139983156983157983154983137983148 O983157983156983140983151983151983154 G983154983145983148983148983141

AGK01CB Anodized Aluminum

AGK01DB Dark BronzeBrown

AGK01TB Stonewood Beige

AGK01WB Amana White

AGK01SB Custom Colors

PGK01DB Dark BronzeBrown

PGK01TB Stonewood Beige

PGK01WB Amana White

AGKor

PGK

SGK

DK900DCondensate Drain Kit(use with WS900E)

DK9001DCondensate Drain Kit(use with WS900B)

DK900D

PWHK01C Wire Harness Kit

REK10BRemote Escutcheon Kit(10-pack)

REK10A Remote Escutcheon Plates

8182019 mc-dptac

httpslidepdfcomreaderfullmc-dptac 1220

12 wwwamana-ptaccom

Accessories (cont)S983157983138983085983138983137983155983141 K983145983156The ully skirted sub-base conceals wiring whileproviding strong support i needed Plug-in receptacleand ield-wiring access speeds installation Electricalaccessories such as use holders circuit breakers anddisconnect switches meet NEC requirements

L983141983158983141983148983145983150983143 L983141983143983155Gives wall sleeve ront support and helps to level theunit or installation

H983137983154983140983085983159983145983154983141 K983145983156983155Used to permanently wire to the chassis when astandard sub-base and power cord are not utilized

F983137983139983156983151983154983161 I983150983155983156983137983148983148983141983140 Feature Code - W

P983151983159983141983154 D983145983155983139983151983150983150983141983139983156 S983159983145983156983139983144The PSHWA power disconnect switch can be usedor 265-volt or 230208-volt physical disconnectwhere required by local codes The switch is ratedat 30-amp capacity The switch is or use with andAmanareg brand standard sub-bases or PTPWHWK4Hard Wire Kit

F983157983155983141 H983151983148983140983141983154 K983145983156Cartridge-style uses can be installed in the useholder or use in the sub-base or chassis Available in15 20 and 30 amp (included on 265-volt unit)

C983145983154983139983157983145983156 B983154983141983137983147983141983154 K983145983156 (983090983091983088983090983088983096V 983151983150983148983161)The circuit breaker kit available in 15 20 or 30 ampcan be used with Amana brand sub-bases It givesovercurrent protection and its location allows you toturn the unit on or off without tools

PTSB215E 115V15A

PTSB320E 230208V 1520A

PTSB330E 230208V 30A

PTSB420E 265V 1520A

PTSB430E 265V 25A

PTSB000E Non-electrical

LL2B Leveling legs or WS9 sleeves

PTPWHWK4 Armored Cable ndash all voltages

PTQC3A Quick Connect ndash 230208V

PTQC4A Quick Connect ndash 265 amp 115 V

PSHW03A 230208V

PSHW04A 265V

FHK315E 230208V 15A

FHK315E 230208V 15A (R-410A)

FHK320C 230208V 20A

FHK320E 230208V 20A (R-410A)

FHK330C 230208V 30A

FHK330E 230208V 30A (R-410A)

CBK15C 15 amp Circuit Breaker Kit

CBK20C 20 amp Circuit Breaker Kit

CBK30C 30 amp Circuit Breaker Kit

8182019 mc-dptac

httpslidepdfcomreaderfullmc-dptac 1320

13Specifications and Accessories Catalog

Accessories (cont)

P983151983159983141983154 V983141983150983156 K983145983156Installation o Power Vent increases CFM up toapproximately 95 Vent door will automatically closewhen unit an is off

F983137983139983156983151983154983161 I983150983155983156983137983148983148983141983140 Feature Code - VR-410A models must have these kits installed atthe actory

C983151983150983140983141983150983155983141983154 B983137983142983142983148983141 K983145983156For use on non-baffled grilles These delectors directthe air in toward the center and away rom the inlet toprevent recirculation o the hot condenser air

S983157983138983085983138983137983155983141 E983160983156983141983150983155983145983151983150 C983151983158983141983154 K983145983156Converts older 30-amp sub-bases to allow or installationo the larger 30-amp LCDI power cord and plugs

S983141983139983157983154983145983156983161 K983141983161 L983151983139983147983155In conjunction with the tamper-resistant ront theinstallation o Amanareg brand security key locks preventstampering o the controls used to set temperature heatingand cooling unctions UL approved or institutionaluse only

C983151983150983140983141983150983155983137983156983141 R983141983149983151983158983137983148 P983157983149983152Can be ield-installed Assists in removing condensatedeveloped by heat pump operation and transers it to

indoor coil to dissipate into room while adding humidityto the room

F983137983139983156983151983154983161 I983150983155983156983137983148983148983141983140 Feature Code - P

PVK3A 230208V ndash R-22

PVK4A 265V ndash R-22

D983157983139983156 E983160983156983141983150983155983145983151983150 K983145983156Extends air distribution to an adjoining room Consistsof a main duct for the room of origin and an extensionduct to reach the adjoining room and terminal ductPTDK01A allows for the ldquoBrdquo series unit to work with theldquoArdquo series duct kits

MDK02B Main Duct ndash R-22

MDK01E Main Duct ndash R-410A

EDK02B 42 Extension Duct

TRANSITION BAFFLES

Main Duct Kit

TDK02B Terminal Duct

PTDK01A Transition Duct Only ndash R-22

PTDK01E Transition Duct Only ndash R-410A

Extension Duct Kit

Terminal Duct Kit

DGK1B Condenser Baffle Kit

SBEC10A 10 Pack

Basepan

Condenser

Condenser Baffles

KL03B Security Key Lock (R-22)

KL03E Security Key Lock (R-410A)

CDP302 230208V ndash R-22

CDP402 265V ndash R-22

CDP303E 230208V ndash R-410A

8182019 mc-dptac

httpslidepdfcomreaderfullmc-dptac 1420

14 wwwamana-ptaccom

Accessories (cont)

HWK03B Hydronic Water Kit ndash R-22

HVK03B Hydronic Steam Kit ndash R-22

HWK03E Hydronic Water Kit ndash R-410A

HVK03E Hydronic Steam Kit ndash R-410A

ThermostatsThe ollowing thermostats offer remote control Any thermostat other than those listed must be submitted to Goodman Company LPor approval prior to use

H983161983140983154983151983150983145983139 H983141983137983156 K983145983156Add-on kits it all units allowing the addition o hydronicwater or hydronic steam heat to cooling and heating unitsThe kits eature lef- or right-hand piping Unit retainscomplete service access with a kit installed Unit must beconnected to and operated by a wall thermostat

Hydronic Heat Kit Top View

Hydronic Heat Kit Right View

M983151983140983141983148 H983141983137983156 S983156983137983143983141983155 C983151983151983148 S983156983137983143983141983155 F983137983150 S983152983141983141983140 983151983142 W983145983154983141983155R983141983153983157983145983154983141983140

T983141983149983152L983145983149983145983156983145983150983143

B983137983139983147983148983145983156 D983145983155983152983148983137983161 T983161983152983141S983144983137983152983141 983078

O983154983145983141983150983156983137983156983145983151983150C983151983150983150983141983139983156983145983151983150

2246002 1 1 1 5 No Yes Digital Manual RectHoriz Wired

2246003 2 2 2 7 Yes Yes Digital Manual RectHoriz Wired

2246007 2 2 1 7 Yes Yes Digital Auto-Change RectHoriz Wired

2246008 2 2 1 7 Yes Yes Digital Programmable RectHoriz Wired

DS01E 2 2 2 0 Yes Yes Digital Manual RectHoriz Wireless

Battery powered but has optional hard wire capability Requires DT01G Antennae or operation

Hydronic Heat KitSide View

8182019 mc-dptac

httpslidepdfcomreaderfullmc-dptac 1520

15Specifications and Accessories Catalog

Accessories (cont)P983151983159983141983154 D983151983151983154 K983145983156Vent door will automatically open when unit an is on

Factory Installed Feature Code - D

H983161983140983154983151983150983145983139 V983137983148983158983141983155Water and steam valves are available or use with theHWK03 (water) and HVK03 (steam) heat kits

W983145983154983141983148983141983155983155 RF (R983137983140983145983151 F983154983141983153983157983141983150983139983161) C983151983150983156983154983151983148983155All DigiSmart PTACs come actory-ready to be con-trolledvia wireless RF devices 24 Ghz 802 154 protocol assuresrobust communications and response

W983137983148983148 S983148983141983141983158983141 E983160983156983141983150983155983145983151983150 A983140983137983152983156983141983154 K983145983156983155Room-side extension kits to increase the depth o theexisting sleeve to allow or an industry-standard PTAC tobe installed

C983157983154983156983137983145983150 B983137983142983142983148983141 K983145983156The color matched polymer curtain baffles help toprevent curtains rom alling into the discharge airstream and causing recirculation reducing efficienciesand shortening compressor lie

PDK3A 230208V ndash R-22

PDK4A 265V ndash R-22

PDK3E 230208V ndash R-410A

PDK4E 265V ndash R-410A

VS2WNCA 2-way24VNCSteam VS2WNOA 2-way24VNOSteam VW2WNCA 2-way24VNCEnd Switch

VW2WNOA 2-way24VNOEnd Switch VW3WNC2B 3-way24VNCNOEnd Switch

Poptop Actuator

DS01EThermostat 2-way2 Communications

DD01EOccupancy SensorEMS Activation2

DT01GAntenna RouterFactory InstalledFeature Code - R

GT01GGeneric RadioAntenna Router3

DD01F Door Switch EMS Activation2

DP01G Web-enabled Platorm Server

DL01GWeb-enabled PlatormServer Link BAC-NET capable

DR01G Mesh Repeater1

DL01G-SERIAL

Serial Repeater1

1 Consult Amana Sales representative priorto purchase

2 Requires DT01G or use3 Requires DS01E or use

SECM1001A 15 Extension or 12frac12 Climate Master Sleeve (10 Pack)

SEZA0501A 25 Extension or 11frac12 Zone Air Sleeve (5 pack)

PTCB10B 10 Pack or R-22 units

PTCB10E 10 Pack or R-410A units

8182019 mc-dptac

httpslidepdfcomreaderfullmc-dptac 1620

16 wwwamana-ptaccom

Unit with Accessory Wall Sleeve and Sub-base Accessory

3

11

6- 18 9- 91624 -5 16

40

42

Location of external drain holes on bottom flange of Wall Sleeve

3 Clearance

to side walls

Air Flow

Air Flow

Air Flow

Air Discharge Grille ControlDoor

T983151983152 V983145983141983159

F983154983151983150983156 V98314598314198315958 LCDI CORD SET mdash 230V208V UNIT

58 CORD SET 230V208V UNIT

18 CORD SET 2 65V UNIT

3-14

MIN

2

MAX

2-58

42

16-116

RI GHTLEFT

1 and frac34 Concentric knock-outs back ampbottom o sub-base (electrical only)

R983145983143983144983156 V983145983141983159

2frac34

4

11⅜

983225983219 frasl ₁₆

983225983219 frasl ₁₆ 1⅜

16983225 frasl ₁₆

1⅜Arch Grille

⅞Stamped Grille

14⅛Wall Sleeve

21frac12

7⅜

Optional

Sub-base

HingedControlDoor

15deg

40deg

Air discharge grille is reversible to provideeither 15deg or 40deg discharge angle

frac12 ODCopperDrain Tube

8182019 mc-dptac

httpslidepdfcomreaderfullmc-dptac 1720

17Specifications and Accessories Catalog

Framing or Accessory Wall Sleeve (WS9XX)F983137983155983156983141983150983145983150983143 W983137983148983148 S983148983141983141983158983141When installed in an opening the Wall Sleeve must behorizontally level (side-to-side) and pitched frac14 bubble to the outside

(NOTE To ensure unitrsquos maximum efficiency DO NOT over- or under-pitch)

I983150983155983156983137983148983148983137983156983145983151983150 N9831519831569831419831551 I Sub-base (PTSBE) is installed allow minimum

3frac14 height clearance and maximum 5 heightclearance between wall sleeve and loor allowminimum 2frac34 protrusion rom a inished wallSee Note 4 if using hydronic units

2 Drain Kit (DK900D) shipped separately Can bemounted either right side lef side or bottom osleeve I mounted to bottom o sleeve allow2 height clearance rom loor to bottom o sleeve

3 For UL approval 265V units must use Amanareg brandSub-base (PTSBE) or Amanareg brand Hard WireKit (PSHW04A) Overcurrent protection on 265V unitsmust be by cartridge-style time delay uses whichare included and factory-installed on the Amanareg brand 265V chassis

4 I Hydronic Kit (HWK03 or HVK03) is installedWall Sleeve must extend exactly 3 into the roomrom the inished interior wall I using the Amana reg brand Sub-base (PTSBE) only the minimum3frac14 height clearance between wall sleeve and loor

is permissible Unit must also be operated with aremote-mounted thermostat

5 I Duct Kit (MDK) is installed allow a minimum o2⅜ into the room rom the inished interior wall

MountingHoles(Drilled byInstaller)

PlasticAnchor

Screws

ExpansionAnchor Bolt

Toggle Bolt

Wood Screw

AlternativeFastening Method(Field Supplied)

Wall Sleeve must extend a minimum o frac14 beyond outside wall to allow orproper caulking

FINISHED FLOOR

4 2 1 4

16 14

MIN

MAIN STUD

JACK STUDS

HEADER - 4 x 4 OR

DOUBLE 2x 4 ON EDGE

SUB-FLOOR

CRIPPLE

JACK STUD

ADJUST FRAMING TO

SECURE THIS DIMENSION

Wall sleeve opening height should be squared withwall sleeve opening width

H = 16frac14

W = 42frac14

8182019 mc-dptac

httpslidepdfcomreaderfullmc-dptac 1820

Notes

8182019 mc-dptac

httpslidepdfcomreaderfullmc-dptac 1920

Our continuing commitment to quality products may mean a change in speciications without noticecopy 2015 Goodman Company LP Amana is a registered trademark o Maytag Corporation or its related

companies and is used under license to Goodman Company LP Houston TX USA All rights reserved

Quiet two-an motor system

Energy-eicient perormance

DigiSmartreg wireless controls on select models

Wise DecisionItrsquos an Amanareg brand

8182019 mc-dptac

httpslidepdfcomreaderfullmc-dptac 2020

Our continuing commitment to quality products may mean a change in speciications without notice copy 2015 Goodman Company LPAmana is a registered trademark o Maytag Corporation or its related companies and is used under license to Goodman Company L P

wwwamana-ptaccom

Call your Amana brand PTAC sales representative at 800-647-2982 or complete details

Beore purchasing this appliance read important inormation about its estimated annual energy

consumption yearly operating cost or energy efficiency rating that is available rom your retailer

A legacy o comortThe impeccable reputation oan American original

Amana heating and cooling systems are a part of the

enduring legacy of one of Americarsquos most recognized

and respected brands Originating eight decades ago in

Amana Iowa the brand is synonymous with long-last-

ing premium-quality products mdash from home appliances

to heating and air conditioning equipment Chances

are you and generations beore you have enjoyed the

dependable performance and longevity the Amana

brand continues to deliver

MC-DPTAC 07-15Supersedes 06-15

Page 8: mc-dptac

8182019 mc-dptac

httpslidepdfcomreaderfullmc-dptac 820

8 wwwamana-ptaccom

Product Speciications PTH Models mdash CoolingHeat PumpElectric HeatM983151983140983141983148 983089 983094 983096 983097

PTH073GAXXX

PTH093GAXXX

PTH123GAXXX

PTH153GAXXX

PTH074GAXXX

PTH094GAXXX

PTH124GAXXX

PTH154GAXXX

Voltage 983225 983219 230 208 230 208 230 208 230 208 265 265 265 265

Capacity (BTUh) 7600 7600 9000 900012000 12000

14700 14700

7600 9100 12000 14600

Amps 983225⁰ 39 39 42 42 58 58 70 70 31 37 50 61

Watts 983225⁰ 650 633 750 750 1090 1090 1515 1515 650 758 1091 1505

EER 117 120 120120 110110 97 97 117 120 110 97

U983150983145983156 983159983145983156983144983151983157983156 E983148983141983139983156983154983145983139 H983141983137983156983141983154

Min Circuit Amps 983090 983092983089983088 47 51 71 85 38 45 61 74

CFM (CoolWet Coil) High 340 330 340 390 340 330 340 390Low 245 245 245 340 245 245 245 340

CFM (Dry Coil)High 370 360 370 410 370 360 370 410

Low 270 270 270 370 270 270 270 370

Ventilated Air CFM (Fan Only) 65 65 65 65 65 65 65 65

Dehumidiication (PintsHr) 17 22 36 44 17 22 36 44

Net Weight (lbs) 108 112 115 126 108 112 115 125

Ship Weight (lbs) 123 127 132 143 123 127 132 142

Actual vent CFM perormance will vary due to application and installation conditions

N983151983156983141983155983225 All 265-volt models must use an Amanareg brand sub-base (PTSB4E) or an Amanareg brand hard-wire kit (PTPWHWK4)983218 Minimum Circuit Ampacity (MCA) ratings conorm to the National Electric Code however local codes should apply

Minimum voltage on 230208-volt models is 197 volts maximum is 253 volts983219 Minimum voltage on 265-volt models is 239 volts maximum is 292 volts⁴ Overcurrent protection or all units without electric heaters is 15 amps Overcurrent protection on 265-volt models must be

cartridge-style time-delay uses (included and actory-installed on all Amanareg brand 265-volt chassis)⁵ Heating capacity and efficiency based on unit operation without condensate pump unit automatically switches to electric

heat at approximately 24degF outdoor ambient⁶ Speciy two-digit heater kW size to complete model number⁷ R-410A rerigerant used in all systems⁸ All units meet or exceed ASHRAE 901 standards⁹ All units less than 250 volts have a Leak Current Detector Interrupter (LCDI) power cord and meet UL 484 standards983225⁰ Reer to electric heat perormance data or total MCA and recommended overcurrent protection Amps and Watts notation

reers to compressor only

8182019 mc-dptac

httpslidepdfcomreaderfullmc-dptac 920

9Specifications and Accessories Catalog

Actual vent CFM perormance will vary due to application and installation conditions

N983151983156983141983155983225 Minimum Circuit Ampacity (MCA) ratings conorm to the National Electric Code however local codes should apply983090 Minimum voltage on 115-volt models is 109 volts maximum is 127 volts983091 Overcurrent protection or all units without electric heaters is 15 amps⁴ R-410A rerigerant used in all systems

⁵ All units meet or exceed ASHRAE 901 standards⁶ All units less than 250 volts have a Leak Current Detector Interrupter (LCDI) power cord and meet UL 484 standards

M983151983140983141983148 983093 983094PTC

072GXXXPTC

092GXXX

Voltage 983090 115 115

Capacity (BTUh) 7000 9000

Amps 69 83

Watts 585 795

EER 119 113

Min Circuit Amps 983089 983091 83 101

CFM (CoolWet Coil)High 290 290

Low 264 264

CFM (Dry Coil)High 310 310

Low 282 282

Ventilated Air (Fan Only) 65 65

Dehumidiication (PintsHr) 17 23

Net Weight (lbs) 98 102

Ship Weight (lbs) 113 117

Product Speciications PTC 115-Volt Models mdashCoolingHydronic Heat or No-Heat Models

8182019 mc-dptac

httpslidepdfcomreaderfullmc-dptac 1020

10 wwwamana-ptaccom

Product Speciications PTH Models mdash Reverse-Cycle Heating PerormanceH983141983137983156983145983150983143

C983137983152983137983139983145983156983161983225PTH073G

AXXXPTH093G

AXXXPTH123G

AXXXPTH153G

AXXXPTH074G

AXXXPTH094G

AXXXPTH124G

AXXXPTH154G

AXXX

Voltage 983225 983219 230 208 230 208 230 208 230 208 265 265 265 265

BTUh ⁵ 6800 6800 8300 8100 11500 11300 13800 13600 6800 8300 11400 13700

Amps 983225⁰ 39 39 42 42 58 58 70 70 31 37 50 61

Watts 983225⁰ 585 585 715 700 1085 1035 1350 1330 585 715 1080 1340

COP ⁵ 34 34 34 34 31 32 30 30 34 34 31 30

CFM (Dry) 370 360 370 410 370 360 370 410

COP = Coefficiency o Perormance per AHRI Test Procedures units are rated or capacities and efficiencies

N983151983156983141983155

983225 All 265-volt models must use an Amanareg brand sub-base (PTSB4E) or an Amanareg brand hard-wire kit (PTPWHWK4)983218 Minimum branch circuit ampacity ratings conorm to the National Electric Code however local codes should apply983219 Minimum voltage on 230208-volt models is 197 volts maximum is 253 volts

Minimum voltage on 265-volt models is 239 volts maximum is 292 volts⁴ Overcurrent protection or all units without electric heaters is 15 amps Overcurrent protection on 265-volt models must

be cartridge-style time-delay uses (included and actory-installed on all Amanareg brand 265-volt chassis)⁵ Heating capacity and efficiency based on unit operation without condensate pump unit automatically switches to electric

heat at approximately 24degF outdoor ambient⁶ Speciy two-digit heater kW size to complete model number⁷ R-410A rerigerant used in all systems⁸ All units meet or exceed ASHRAE 901 standards⁹ All units less than 250 volts have a Leak Current Detector Interrupter (LCDI) power cord and meet UL 484 standards983225⁰ Reer to electric heat perormance data or total MCA and recommended overcurrent protection

Amps and Watts notation reers to compressor only

Product Speciications PTC PTH Models mdash Electric Heat Perormance(Primary Heating or PTC Models Auxiliary Heating or PTH Models See below or Power Cord Coniguration)

V983151983148983156983137983143983141E983148983141983139983156983154983145983139H983141983137983156983141983154

S983145983162983141 (983147W)

N983151 983151983142S983156983137983143983141983155

N983151983149983145983150983137983148 H983141983137983156983145983150983143 (BTU983144)T983151983156983137983148

W983137983156983156983155983094T983151983156983137983148 A983149983152983155

M983145983150 C983145983154983139983157983145983156 A983149983152983137983139983145983156983161983218

MOP983092(983137983149983152983155)

P983151983159983141983154C983151983154983140

10486269830911048624V 104862610486241048632V 104862610486301048629V

230208V 15 13 1 5100 4200 - - 1570 1295 68 62 85 15 6-15 P

230208V 25 21 1 8500 6800 - - 2570 2115 112 101 141 15 6-15 P

230208V 35 30 1 12000 9900 - - 3570 2935 155 141 195 20 6-20 P

230208V 50 41 1 17100 14000 - - 5070 4160 221 200 276 30 6-30 P

265V 15 1 - - - - 5100 1570 59 74 15 7-20P

265V 25 1 - - - - 8500 2570 97 122 15 7-20 P

265V 37 1 - - - - 12600 3770 142 179 20 7-20 P265V 5 1 - - - - 17100 5070 192 239 25 7-30 P

N983151983156983141983155983225 All 265-volt models must use an Amanareg brand sub-base (PTSB4E) or an Amanareg brand hard-wire kit (PTPWHWK4)983218 Minimum branch circuit ampacity ratings conorm to the National Electric Code however local codes should apply983219 Minimum voltage on 230208-volt models is 197 volts maximum is 253 volts Minimum voltage on 265-volt models is 239 volts maximum is 292 volts⁴ Overcurrent protection or all units without electric heaters is 15 amps Overcurrent protection on 265-volt models must be cartridge-style

time-delay uses (included and actory-installed on all Amanareg brand 265-volt chassis)⁵ Heating capacity and efficiency based on unit operation without condensate pump unit automatically switches to electric heat at

approximately 24degF outdoor ambient⁶ Total watts or 15000 BTUh models subtract 20 watts or PT070912⁷ Speciy two-digit heater kW size to complete model number⁸ R-410A rerigerant used in all systems⁹ All units meet or exceed ASHRAE 901 standards983225⁰ All units less than 250 volts have a Leak Current Detector Interrupter (LCDI) power cord and meet UL 484 standards

8182019 mc-dptac

httpslidepdfcomreaderfullmc-dptac 1120

11Specifications and Accessories Catalog

AccessoriesW983137983148983148 S983148983141983141983158983141983155All our wall sleeves have industry standard dimensionso 42 wide x 16⅟ ₁₆ high The WS900E SC and INTERNAL14⅛ depth is the industry standard Sleeves maybe shipped separately to allow or installationduring construction

C983151983150983140983141983150983155983137983156983141 D983154983137983145983150 K983145983156Attaches to the wall sleeve base pan or controlledinternal or external disposal o condensate

L983151983159983085V983151983148983156983137983143983141 W983145983154983141 H983137983154983150983141983155983155 K983145983156 (983150983151983156 983155983144983151983159983150)For quick connections o the remote or wiredthermostats wired EMS or ront desk with jumpers andconnectors

R983141983149983151983156983141 E983155983139983157983156983139983144983141983151983150 K983145983156 (983150983151983156 983155983144983151983159983150)Optional kit or use with units controlled via a wiredremote thermostat Covers control touch-pad or wiredthermostat installations

Each ldquoBrdquo kit contains 80 wires and wire nutsenough to attach a thermostat and oneadditional accessory to 10 PTAC units Wirescome in assorted colors or easy attachmentEach ldquoArdquo kit contains 10 Escutcheon plates only

O983157983156983140983151983151983154 G983154983145983148983148983141983155Available in stamped-aluminum or architecturallylouvered or application with an Amana brand WS900Ewall sleeve

AGK Extruded aluminum architectural grille availablewith anodized aluminum inish or a baked-on paintinish or durability Choose rom 3 stock colors or acustom color to blend with your buildingrsquos exteriorcolor scheme Colors include

CB (Clear Anodized) DB (Dark BrownBronze)TB (Stonewood Beige) WB (White)SB (SpecialCustom Colors)

PGK One-piece injection molded grille using a polymerblend o engineered thermoplastic high-impactstrength material with chemical resistance andan exterior UV protective coating

Choose from 3 stock colorsDB (Dark BrownBronze) TB (Stonewood Beige)

WB (White)

S983156983137983150983140983137983154983140983085D983141983152983156983144 S983148983141983141983158983141983155

WS900E-GS Heavy Sound Isolation Insulation Sleeve

WS900E Standard PTAC sleeve

WS900SC Seacoast triple protected

WS900D-INTERNAL

Internal drain only or window-wallinstallations (DK900D sold separately)

E983160983156983154983137 D983141983141983152 S983148983141983141983158983141983155 in several depths orthicker wall installations or special roomconigurations

WS9XXD1 16 to 24 in 1 increments

WS928D1 Extra deep 28

WS930D1 Extra deep 30

WS936D1 Extra deep 36

WS9XXD1-Interna

Extra deep Internal drain onlyor window-wall installations(DK900D sold separately) 1 4

⅛ 4 2

1 6

1

1 6

S983156983137983150983140983137983154983140 O983157983156983140983151983151983154 G983154983145983148983148983141

SGK01B Single Pack

SGK01TB Stonewood Beige

A983154983139983144983145983156983141983139983156983157983154983137983148 O983157983156983140983151983151983154 G983154983145983148983148983141

AGK01CB Anodized Aluminum

AGK01DB Dark BronzeBrown

AGK01TB Stonewood Beige

AGK01WB Amana White

AGK01SB Custom Colors

PGK01DB Dark BronzeBrown

PGK01TB Stonewood Beige

PGK01WB Amana White

AGKor

PGK

SGK

DK900DCondensate Drain Kit(use with WS900E)

DK9001DCondensate Drain Kit(use with WS900B)

DK900D

PWHK01C Wire Harness Kit

REK10BRemote Escutcheon Kit(10-pack)

REK10A Remote Escutcheon Plates

8182019 mc-dptac

httpslidepdfcomreaderfullmc-dptac 1220

12 wwwamana-ptaccom

Accessories (cont)S983157983138983085983138983137983155983141 K983145983156The ully skirted sub-base conceals wiring whileproviding strong support i needed Plug-in receptacleand ield-wiring access speeds installation Electricalaccessories such as use holders circuit breakers anddisconnect switches meet NEC requirements

L983141983158983141983148983145983150983143 L983141983143983155Gives wall sleeve ront support and helps to level theunit or installation

H983137983154983140983085983159983145983154983141 K983145983156983155Used to permanently wire to the chassis when astandard sub-base and power cord are not utilized

F983137983139983156983151983154983161 I983150983155983156983137983148983148983141983140 Feature Code - W

P983151983159983141983154 D983145983155983139983151983150983150983141983139983156 S983159983145983156983139983144The PSHWA power disconnect switch can be usedor 265-volt or 230208-volt physical disconnectwhere required by local codes The switch is ratedat 30-amp capacity The switch is or use with andAmanareg brand standard sub-bases or PTPWHWK4Hard Wire Kit

F983157983155983141 H983151983148983140983141983154 K983145983156Cartridge-style uses can be installed in the useholder or use in the sub-base or chassis Available in15 20 and 30 amp (included on 265-volt unit)

C983145983154983139983157983145983156 B983154983141983137983147983141983154 K983145983156 (983090983091983088983090983088983096V 983151983150983148983161)The circuit breaker kit available in 15 20 or 30 ampcan be used with Amana brand sub-bases It givesovercurrent protection and its location allows you toturn the unit on or off without tools

PTSB215E 115V15A

PTSB320E 230208V 1520A

PTSB330E 230208V 30A

PTSB420E 265V 1520A

PTSB430E 265V 25A

PTSB000E Non-electrical

LL2B Leveling legs or WS9 sleeves

PTPWHWK4 Armored Cable ndash all voltages

PTQC3A Quick Connect ndash 230208V

PTQC4A Quick Connect ndash 265 amp 115 V

PSHW03A 230208V

PSHW04A 265V

FHK315E 230208V 15A

FHK315E 230208V 15A (R-410A)

FHK320C 230208V 20A

FHK320E 230208V 20A (R-410A)

FHK330C 230208V 30A

FHK330E 230208V 30A (R-410A)

CBK15C 15 amp Circuit Breaker Kit

CBK20C 20 amp Circuit Breaker Kit

CBK30C 30 amp Circuit Breaker Kit

8182019 mc-dptac

httpslidepdfcomreaderfullmc-dptac 1320

13Specifications and Accessories Catalog

Accessories (cont)

P983151983159983141983154 V983141983150983156 K983145983156Installation o Power Vent increases CFM up toapproximately 95 Vent door will automatically closewhen unit an is off

F983137983139983156983151983154983161 I983150983155983156983137983148983148983141983140 Feature Code - VR-410A models must have these kits installed atthe actory

C983151983150983140983141983150983155983141983154 B983137983142983142983148983141 K983145983156For use on non-baffled grilles These delectors directthe air in toward the center and away rom the inlet toprevent recirculation o the hot condenser air

S983157983138983085983138983137983155983141 E983160983156983141983150983155983145983151983150 C983151983158983141983154 K983145983156Converts older 30-amp sub-bases to allow or installationo the larger 30-amp LCDI power cord and plugs

S983141983139983157983154983145983156983161 K983141983161 L983151983139983147983155In conjunction with the tamper-resistant ront theinstallation o Amanareg brand security key locks preventstampering o the controls used to set temperature heatingand cooling unctions UL approved or institutionaluse only

C983151983150983140983141983150983155983137983156983141 R983141983149983151983158983137983148 P983157983149983152Can be ield-installed Assists in removing condensatedeveloped by heat pump operation and transers it to

indoor coil to dissipate into room while adding humidityto the room

F983137983139983156983151983154983161 I983150983155983156983137983148983148983141983140 Feature Code - P

PVK3A 230208V ndash R-22

PVK4A 265V ndash R-22

D983157983139983156 E983160983156983141983150983155983145983151983150 K983145983156Extends air distribution to an adjoining room Consistsof a main duct for the room of origin and an extensionduct to reach the adjoining room and terminal ductPTDK01A allows for the ldquoBrdquo series unit to work with theldquoArdquo series duct kits

MDK02B Main Duct ndash R-22

MDK01E Main Duct ndash R-410A

EDK02B 42 Extension Duct

TRANSITION BAFFLES

Main Duct Kit

TDK02B Terminal Duct

PTDK01A Transition Duct Only ndash R-22

PTDK01E Transition Duct Only ndash R-410A

Extension Duct Kit

Terminal Duct Kit

DGK1B Condenser Baffle Kit

SBEC10A 10 Pack

Basepan

Condenser

Condenser Baffles

KL03B Security Key Lock (R-22)

KL03E Security Key Lock (R-410A)

CDP302 230208V ndash R-22

CDP402 265V ndash R-22

CDP303E 230208V ndash R-410A

8182019 mc-dptac

httpslidepdfcomreaderfullmc-dptac 1420

14 wwwamana-ptaccom

Accessories (cont)

HWK03B Hydronic Water Kit ndash R-22

HVK03B Hydronic Steam Kit ndash R-22

HWK03E Hydronic Water Kit ndash R-410A

HVK03E Hydronic Steam Kit ndash R-410A

ThermostatsThe ollowing thermostats offer remote control Any thermostat other than those listed must be submitted to Goodman Company LPor approval prior to use

H983161983140983154983151983150983145983139 H983141983137983156 K983145983156Add-on kits it all units allowing the addition o hydronicwater or hydronic steam heat to cooling and heating unitsThe kits eature lef- or right-hand piping Unit retainscomplete service access with a kit installed Unit must beconnected to and operated by a wall thermostat

Hydronic Heat Kit Top View

Hydronic Heat Kit Right View

M983151983140983141983148 H983141983137983156 S983156983137983143983141983155 C983151983151983148 S983156983137983143983141983155 F983137983150 S983152983141983141983140 983151983142 W983145983154983141983155R983141983153983157983145983154983141983140

T983141983149983152L983145983149983145983156983145983150983143

B983137983139983147983148983145983156 D983145983155983152983148983137983161 T983161983152983141S983144983137983152983141 983078

O983154983145983141983150983156983137983156983145983151983150C983151983150983150983141983139983156983145983151983150

2246002 1 1 1 5 No Yes Digital Manual RectHoriz Wired

2246003 2 2 2 7 Yes Yes Digital Manual RectHoriz Wired

2246007 2 2 1 7 Yes Yes Digital Auto-Change RectHoriz Wired

2246008 2 2 1 7 Yes Yes Digital Programmable RectHoriz Wired

DS01E 2 2 2 0 Yes Yes Digital Manual RectHoriz Wireless

Battery powered but has optional hard wire capability Requires DT01G Antennae or operation

Hydronic Heat KitSide View

8182019 mc-dptac

httpslidepdfcomreaderfullmc-dptac 1520

15Specifications and Accessories Catalog

Accessories (cont)P983151983159983141983154 D983151983151983154 K983145983156Vent door will automatically open when unit an is on

Factory Installed Feature Code - D

H983161983140983154983151983150983145983139 V983137983148983158983141983155Water and steam valves are available or use with theHWK03 (water) and HVK03 (steam) heat kits

W983145983154983141983148983141983155983155 RF (R983137983140983145983151 F983154983141983153983157983141983150983139983161) C983151983150983156983154983151983148983155All DigiSmart PTACs come actory-ready to be con-trolledvia wireless RF devices 24 Ghz 802 154 protocol assuresrobust communications and response

W983137983148983148 S983148983141983141983158983141 E983160983156983141983150983155983145983151983150 A983140983137983152983156983141983154 K983145983156983155Room-side extension kits to increase the depth o theexisting sleeve to allow or an industry-standard PTAC tobe installed

C983157983154983156983137983145983150 B983137983142983142983148983141 K983145983156The color matched polymer curtain baffles help toprevent curtains rom alling into the discharge airstream and causing recirculation reducing efficienciesand shortening compressor lie

PDK3A 230208V ndash R-22

PDK4A 265V ndash R-22

PDK3E 230208V ndash R-410A

PDK4E 265V ndash R-410A

VS2WNCA 2-way24VNCSteam VS2WNOA 2-way24VNOSteam VW2WNCA 2-way24VNCEnd Switch

VW2WNOA 2-way24VNOEnd Switch VW3WNC2B 3-way24VNCNOEnd Switch

Poptop Actuator

DS01EThermostat 2-way2 Communications

DD01EOccupancy SensorEMS Activation2

DT01GAntenna RouterFactory InstalledFeature Code - R

GT01GGeneric RadioAntenna Router3

DD01F Door Switch EMS Activation2

DP01G Web-enabled Platorm Server

DL01GWeb-enabled PlatormServer Link BAC-NET capable

DR01G Mesh Repeater1

DL01G-SERIAL

Serial Repeater1

1 Consult Amana Sales representative priorto purchase

2 Requires DT01G or use3 Requires DS01E or use

SECM1001A 15 Extension or 12frac12 Climate Master Sleeve (10 Pack)

SEZA0501A 25 Extension or 11frac12 Zone Air Sleeve (5 pack)

PTCB10B 10 Pack or R-22 units

PTCB10E 10 Pack or R-410A units

8182019 mc-dptac

httpslidepdfcomreaderfullmc-dptac 1620

16 wwwamana-ptaccom

Unit with Accessory Wall Sleeve and Sub-base Accessory

3

11

6- 18 9- 91624 -5 16

40

42

Location of external drain holes on bottom flange of Wall Sleeve

3 Clearance

to side walls

Air Flow

Air Flow

Air Flow

Air Discharge Grille ControlDoor

T983151983152 V983145983141983159

F983154983151983150983156 V98314598314198315958 LCDI CORD SET mdash 230V208V UNIT

58 CORD SET 230V208V UNIT

18 CORD SET 2 65V UNIT

3-14

MIN

2

MAX

2-58

42

16-116

RI GHTLEFT

1 and frac34 Concentric knock-outs back ampbottom o sub-base (electrical only)

R983145983143983144983156 V983145983141983159

2frac34

4

11⅜

983225983219 frasl ₁₆

983225983219 frasl ₁₆ 1⅜

16983225 frasl ₁₆

1⅜Arch Grille

⅞Stamped Grille

14⅛Wall Sleeve

21frac12

7⅜

Optional

Sub-base

HingedControlDoor

15deg

40deg

Air discharge grille is reversible to provideeither 15deg or 40deg discharge angle

frac12 ODCopperDrain Tube

8182019 mc-dptac

httpslidepdfcomreaderfullmc-dptac 1720

17Specifications and Accessories Catalog

Framing or Accessory Wall Sleeve (WS9XX)F983137983155983156983141983150983145983150983143 W983137983148983148 S983148983141983141983158983141When installed in an opening the Wall Sleeve must behorizontally level (side-to-side) and pitched frac14 bubble to the outside

(NOTE To ensure unitrsquos maximum efficiency DO NOT over- or under-pitch)

I983150983155983156983137983148983148983137983156983145983151983150 N9831519831569831419831551 I Sub-base (PTSBE) is installed allow minimum

3frac14 height clearance and maximum 5 heightclearance between wall sleeve and loor allowminimum 2frac34 protrusion rom a inished wallSee Note 4 if using hydronic units

2 Drain Kit (DK900D) shipped separately Can bemounted either right side lef side or bottom osleeve I mounted to bottom o sleeve allow2 height clearance rom loor to bottom o sleeve

3 For UL approval 265V units must use Amanareg brandSub-base (PTSBE) or Amanareg brand Hard WireKit (PSHW04A) Overcurrent protection on 265V unitsmust be by cartridge-style time delay uses whichare included and factory-installed on the Amanareg brand 265V chassis

4 I Hydronic Kit (HWK03 or HVK03) is installedWall Sleeve must extend exactly 3 into the roomrom the inished interior wall I using the Amana reg brand Sub-base (PTSBE) only the minimum3frac14 height clearance between wall sleeve and loor

is permissible Unit must also be operated with aremote-mounted thermostat

5 I Duct Kit (MDK) is installed allow a minimum o2⅜ into the room rom the inished interior wall

MountingHoles(Drilled byInstaller)

PlasticAnchor

Screws

ExpansionAnchor Bolt

Toggle Bolt

Wood Screw

AlternativeFastening Method(Field Supplied)

Wall Sleeve must extend a minimum o frac14 beyond outside wall to allow orproper caulking

FINISHED FLOOR

4 2 1 4

16 14

MIN

MAIN STUD

JACK STUDS

HEADER - 4 x 4 OR

DOUBLE 2x 4 ON EDGE

SUB-FLOOR

CRIPPLE

JACK STUD

ADJUST FRAMING TO

SECURE THIS DIMENSION

Wall sleeve opening height should be squared withwall sleeve opening width

H = 16frac14

W = 42frac14

8182019 mc-dptac

httpslidepdfcomreaderfullmc-dptac 1820

Notes

8182019 mc-dptac

httpslidepdfcomreaderfullmc-dptac 1920

Our continuing commitment to quality products may mean a change in speciications without noticecopy 2015 Goodman Company LP Amana is a registered trademark o Maytag Corporation or its related

companies and is used under license to Goodman Company LP Houston TX USA All rights reserved

Quiet two-an motor system

Energy-eicient perormance

DigiSmartreg wireless controls on select models

Wise DecisionItrsquos an Amanareg brand

8182019 mc-dptac

httpslidepdfcomreaderfullmc-dptac 2020

Our continuing commitment to quality products may mean a change in speciications without notice copy 2015 Goodman Company LPAmana is a registered trademark o Maytag Corporation or its related companies and is used under license to Goodman Company L P

wwwamana-ptaccom

Call your Amana brand PTAC sales representative at 800-647-2982 or complete details

Beore purchasing this appliance read important inormation about its estimated annual energy

consumption yearly operating cost or energy efficiency rating that is available rom your retailer

A legacy o comortThe impeccable reputation oan American original

Amana heating and cooling systems are a part of the

enduring legacy of one of Americarsquos most recognized

and respected brands Originating eight decades ago in

Amana Iowa the brand is synonymous with long-last-

ing premium-quality products mdash from home appliances

to heating and air conditioning equipment Chances

are you and generations beore you have enjoyed the

dependable performance and longevity the Amana

brand continues to deliver

MC-DPTAC 07-15Supersedes 06-15

Page 9: mc-dptac

8182019 mc-dptac

httpslidepdfcomreaderfullmc-dptac 920

9Specifications and Accessories Catalog

Actual vent CFM perormance will vary due to application and installation conditions

N983151983156983141983155983225 Minimum Circuit Ampacity (MCA) ratings conorm to the National Electric Code however local codes should apply983090 Minimum voltage on 115-volt models is 109 volts maximum is 127 volts983091 Overcurrent protection or all units without electric heaters is 15 amps⁴ R-410A rerigerant used in all systems

⁵ All units meet or exceed ASHRAE 901 standards⁶ All units less than 250 volts have a Leak Current Detector Interrupter (LCDI) power cord and meet UL 484 standards

M983151983140983141983148 983093 983094PTC

072GXXXPTC

092GXXX

Voltage 983090 115 115

Capacity (BTUh) 7000 9000

Amps 69 83

Watts 585 795

EER 119 113

Min Circuit Amps 983089 983091 83 101

CFM (CoolWet Coil)High 290 290

Low 264 264

CFM (Dry Coil)High 310 310

Low 282 282

Ventilated Air (Fan Only) 65 65

Dehumidiication (PintsHr) 17 23

Net Weight (lbs) 98 102

Ship Weight (lbs) 113 117

Product Speciications PTC 115-Volt Models mdashCoolingHydronic Heat or No-Heat Models

8182019 mc-dptac

httpslidepdfcomreaderfullmc-dptac 1020

10 wwwamana-ptaccom

Product Speciications PTH Models mdash Reverse-Cycle Heating PerormanceH983141983137983156983145983150983143

C983137983152983137983139983145983156983161983225PTH073G

AXXXPTH093G

AXXXPTH123G

AXXXPTH153G

AXXXPTH074G

AXXXPTH094G

AXXXPTH124G

AXXXPTH154G

AXXX

Voltage 983225 983219 230 208 230 208 230 208 230 208 265 265 265 265

BTUh ⁵ 6800 6800 8300 8100 11500 11300 13800 13600 6800 8300 11400 13700

Amps 983225⁰ 39 39 42 42 58 58 70 70 31 37 50 61

Watts 983225⁰ 585 585 715 700 1085 1035 1350 1330 585 715 1080 1340

COP ⁵ 34 34 34 34 31 32 30 30 34 34 31 30

CFM (Dry) 370 360 370 410 370 360 370 410

COP = Coefficiency o Perormance per AHRI Test Procedures units are rated or capacities and efficiencies

N983151983156983141983155

983225 All 265-volt models must use an Amanareg brand sub-base (PTSB4E) or an Amanareg brand hard-wire kit (PTPWHWK4)983218 Minimum branch circuit ampacity ratings conorm to the National Electric Code however local codes should apply983219 Minimum voltage on 230208-volt models is 197 volts maximum is 253 volts

Minimum voltage on 265-volt models is 239 volts maximum is 292 volts⁴ Overcurrent protection or all units without electric heaters is 15 amps Overcurrent protection on 265-volt models must

be cartridge-style time-delay uses (included and actory-installed on all Amanareg brand 265-volt chassis)⁵ Heating capacity and efficiency based on unit operation without condensate pump unit automatically switches to electric

heat at approximately 24degF outdoor ambient⁶ Speciy two-digit heater kW size to complete model number⁷ R-410A rerigerant used in all systems⁸ All units meet or exceed ASHRAE 901 standards⁹ All units less than 250 volts have a Leak Current Detector Interrupter (LCDI) power cord and meet UL 484 standards983225⁰ Reer to electric heat perormance data or total MCA and recommended overcurrent protection

Amps and Watts notation reers to compressor only

Product Speciications PTC PTH Models mdash Electric Heat Perormance(Primary Heating or PTC Models Auxiliary Heating or PTH Models See below or Power Cord Coniguration)

V983151983148983156983137983143983141E983148983141983139983156983154983145983139H983141983137983156983141983154

S983145983162983141 (983147W)

N983151 983151983142S983156983137983143983141983155

N983151983149983145983150983137983148 H983141983137983156983145983150983143 (BTU983144)T983151983156983137983148

W983137983156983156983155983094T983151983156983137983148 A983149983152983155

M983145983150 C983145983154983139983157983145983156 A983149983152983137983139983145983156983161983218

MOP983092(983137983149983152983155)

P983151983159983141983154C983151983154983140

10486269830911048624V 104862610486241048632V 104862610486301048629V

230208V 15 13 1 5100 4200 - - 1570 1295 68 62 85 15 6-15 P

230208V 25 21 1 8500 6800 - - 2570 2115 112 101 141 15 6-15 P

230208V 35 30 1 12000 9900 - - 3570 2935 155 141 195 20 6-20 P

230208V 50 41 1 17100 14000 - - 5070 4160 221 200 276 30 6-30 P

265V 15 1 - - - - 5100 1570 59 74 15 7-20P

265V 25 1 - - - - 8500 2570 97 122 15 7-20 P

265V 37 1 - - - - 12600 3770 142 179 20 7-20 P265V 5 1 - - - - 17100 5070 192 239 25 7-30 P

N983151983156983141983155983225 All 265-volt models must use an Amanareg brand sub-base (PTSB4E) or an Amanareg brand hard-wire kit (PTPWHWK4)983218 Minimum branch circuit ampacity ratings conorm to the National Electric Code however local codes should apply983219 Minimum voltage on 230208-volt models is 197 volts maximum is 253 volts Minimum voltage on 265-volt models is 239 volts maximum is 292 volts⁴ Overcurrent protection or all units without electric heaters is 15 amps Overcurrent protection on 265-volt models must be cartridge-style

time-delay uses (included and actory-installed on all Amanareg brand 265-volt chassis)⁵ Heating capacity and efficiency based on unit operation without condensate pump unit automatically switches to electric heat at

approximately 24degF outdoor ambient⁶ Total watts or 15000 BTUh models subtract 20 watts or PT070912⁷ Speciy two-digit heater kW size to complete model number⁸ R-410A rerigerant used in all systems⁹ All units meet or exceed ASHRAE 901 standards983225⁰ All units less than 250 volts have a Leak Current Detector Interrupter (LCDI) power cord and meet UL 484 standards

8182019 mc-dptac

httpslidepdfcomreaderfullmc-dptac 1120

11Specifications and Accessories Catalog

AccessoriesW983137983148983148 S983148983141983141983158983141983155All our wall sleeves have industry standard dimensionso 42 wide x 16⅟ ₁₆ high The WS900E SC and INTERNAL14⅛ depth is the industry standard Sleeves maybe shipped separately to allow or installationduring construction

C983151983150983140983141983150983155983137983156983141 D983154983137983145983150 K983145983156Attaches to the wall sleeve base pan or controlledinternal or external disposal o condensate

L983151983159983085V983151983148983156983137983143983141 W983145983154983141 H983137983154983150983141983155983155 K983145983156 (983150983151983156 983155983144983151983159983150)For quick connections o the remote or wiredthermostats wired EMS or ront desk with jumpers andconnectors

R983141983149983151983156983141 E983155983139983157983156983139983144983141983151983150 K983145983156 (983150983151983156 983155983144983151983159983150)Optional kit or use with units controlled via a wiredremote thermostat Covers control touch-pad or wiredthermostat installations

Each ldquoBrdquo kit contains 80 wires and wire nutsenough to attach a thermostat and oneadditional accessory to 10 PTAC units Wirescome in assorted colors or easy attachmentEach ldquoArdquo kit contains 10 Escutcheon plates only

O983157983156983140983151983151983154 G983154983145983148983148983141983155Available in stamped-aluminum or architecturallylouvered or application with an Amana brand WS900Ewall sleeve

AGK Extruded aluminum architectural grille availablewith anodized aluminum inish or a baked-on paintinish or durability Choose rom 3 stock colors or acustom color to blend with your buildingrsquos exteriorcolor scheme Colors include

CB (Clear Anodized) DB (Dark BrownBronze)TB (Stonewood Beige) WB (White)SB (SpecialCustom Colors)

PGK One-piece injection molded grille using a polymerblend o engineered thermoplastic high-impactstrength material with chemical resistance andan exterior UV protective coating

Choose from 3 stock colorsDB (Dark BrownBronze) TB (Stonewood Beige)

WB (White)

S983156983137983150983140983137983154983140983085D983141983152983156983144 S983148983141983141983158983141983155

WS900E-GS Heavy Sound Isolation Insulation Sleeve

WS900E Standard PTAC sleeve

WS900SC Seacoast triple protected

WS900D-INTERNAL

Internal drain only or window-wallinstallations (DK900D sold separately)

E983160983156983154983137 D983141983141983152 S983148983141983141983158983141983155 in several depths orthicker wall installations or special roomconigurations

WS9XXD1 16 to 24 in 1 increments

WS928D1 Extra deep 28

WS930D1 Extra deep 30

WS936D1 Extra deep 36

WS9XXD1-Interna

Extra deep Internal drain onlyor window-wall installations(DK900D sold separately) 1 4

⅛ 4 2

1 6

1

1 6

S983156983137983150983140983137983154983140 O983157983156983140983151983151983154 G983154983145983148983148983141

SGK01B Single Pack

SGK01TB Stonewood Beige

A983154983139983144983145983156983141983139983156983157983154983137983148 O983157983156983140983151983151983154 G983154983145983148983148983141

AGK01CB Anodized Aluminum

AGK01DB Dark BronzeBrown

AGK01TB Stonewood Beige

AGK01WB Amana White

AGK01SB Custom Colors

PGK01DB Dark BronzeBrown

PGK01TB Stonewood Beige

PGK01WB Amana White

AGKor

PGK

SGK

DK900DCondensate Drain Kit(use with WS900E)

DK9001DCondensate Drain Kit(use with WS900B)

DK900D

PWHK01C Wire Harness Kit

REK10BRemote Escutcheon Kit(10-pack)

REK10A Remote Escutcheon Plates

8182019 mc-dptac

httpslidepdfcomreaderfullmc-dptac 1220

12 wwwamana-ptaccom

Accessories (cont)S983157983138983085983138983137983155983141 K983145983156The ully skirted sub-base conceals wiring whileproviding strong support i needed Plug-in receptacleand ield-wiring access speeds installation Electricalaccessories such as use holders circuit breakers anddisconnect switches meet NEC requirements

L983141983158983141983148983145983150983143 L983141983143983155Gives wall sleeve ront support and helps to level theunit or installation

H983137983154983140983085983159983145983154983141 K983145983156983155Used to permanently wire to the chassis when astandard sub-base and power cord are not utilized

F983137983139983156983151983154983161 I983150983155983156983137983148983148983141983140 Feature Code - W

P983151983159983141983154 D983145983155983139983151983150983150983141983139983156 S983159983145983156983139983144The PSHWA power disconnect switch can be usedor 265-volt or 230208-volt physical disconnectwhere required by local codes The switch is ratedat 30-amp capacity The switch is or use with andAmanareg brand standard sub-bases or PTPWHWK4Hard Wire Kit

F983157983155983141 H983151983148983140983141983154 K983145983156Cartridge-style uses can be installed in the useholder or use in the sub-base or chassis Available in15 20 and 30 amp (included on 265-volt unit)

C983145983154983139983157983145983156 B983154983141983137983147983141983154 K983145983156 (983090983091983088983090983088983096V 983151983150983148983161)The circuit breaker kit available in 15 20 or 30 ampcan be used with Amana brand sub-bases It givesovercurrent protection and its location allows you toturn the unit on or off without tools

PTSB215E 115V15A

PTSB320E 230208V 1520A

PTSB330E 230208V 30A

PTSB420E 265V 1520A

PTSB430E 265V 25A

PTSB000E Non-electrical

LL2B Leveling legs or WS9 sleeves

PTPWHWK4 Armored Cable ndash all voltages

PTQC3A Quick Connect ndash 230208V

PTQC4A Quick Connect ndash 265 amp 115 V

PSHW03A 230208V

PSHW04A 265V

FHK315E 230208V 15A

FHK315E 230208V 15A (R-410A)

FHK320C 230208V 20A

FHK320E 230208V 20A (R-410A)

FHK330C 230208V 30A

FHK330E 230208V 30A (R-410A)

CBK15C 15 amp Circuit Breaker Kit

CBK20C 20 amp Circuit Breaker Kit

CBK30C 30 amp Circuit Breaker Kit

8182019 mc-dptac

httpslidepdfcomreaderfullmc-dptac 1320

13Specifications and Accessories Catalog

Accessories (cont)

P983151983159983141983154 V983141983150983156 K983145983156Installation o Power Vent increases CFM up toapproximately 95 Vent door will automatically closewhen unit an is off

F983137983139983156983151983154983161 I983150983155983156983137983148983148983141983140 Feature Code - VR-410A models must have these kits installed atthe actory

C983151983150983140983141983150983155983141983154 B983137983142983142983148983141 K983145983156For use on non-baffled grilles These delectors directthe air in toward the center and away rom the inlet toprevent recirculation o the hot condenser air

S983157983138983085983138983137983155983141 E983160983156983141983150983155983145983151983150 C983151983158983141983154 K983145983156Converts older 30-amp sub-bases to allow or installationo the larger 30-amp LCDI power cord and plugs

S983141983139983157983154983145983156983161 K983141983161 L983151983139983147983155In conjunction with the tamper-resistant ront theinstallation o Amanareg brand security key locks preventstampering o the controls used to set temperature heatingand cooling unctions UL approved or institutionaluse only

C983151983150983140983141983150983155983137983156983141 R983141983149983151983158983137983148 P983157983149983152Can be ield-installed Assists in removing condensatedeveloped by heat pump operation and transers it to

indoor coil to dissipate into room while adding humidityto the room

F983137983139983156983151983154983161 I983150983155983156983137983148983148983141983140 Feature Code - P

PVK3A 230208V ndash R-22

PVK4A 265V ndash R-22

D983157983139983156 E983160983156983141983150983155983145983151983150 K983145983156Extends air distribution to an adjoining room Consistsof a main duct for the room of origin and an extensionduct to reach the adjoining room and terminal ductPTDK01A allows for the ldquoBrdquo series unit to work with theldquoArdquo series duct kits

MDK02B Main Duct ndash R-22

MDK01E Main Duct ndash R-410A

EDK02B 42 Extension Duct

TRANSITION BAFFLES

Main Duct Kit

TDK02B Terminal Duct

PTDK01A Transition Duct Only ndash R-22

PTDK01E Transition Duct Only ndash R-410A

Extension Duct Kit

Terminal Duct Kit

DGK1B Condenser Baffle Kit

SBEC10A 10 Pack

Basepan

Condenser

Condenser Baffles

KL03B Security Key Lock (R-22)

KL03E Security Key Lock (R-410A)

CDP302 230208V ndash R-22

CDP402 265V ndash R-22

CDP303E 230208V ndash R-410A

8182019 mc-dptac

httpslidepdfcomreaderfullmc-dptac 1420

14 wwwamana-ptaccom

Accessories (cont)

HWK03B Hydronic Water Kit ndash R-22

HVK03B Hydronic Steam Kit ndash R-22

HWK03E Hydronic Water Kit ndash R-410A

HVK03E Hydronic Steam Kit ndash R-410A

ThermostatsThe ollowing thermostats offer remote control Any thermostat other than those listed must be submitted to Goodman Company LPor approval prior to use

H983161983140983154983151983150983145983139 H983141983137983156 K983145983156Add-on kits it all units allowing the addition o hydronicwater or hydronic steam heat to cooling and heating unitsThe kits eature lef- or right-hand piping Unit retainscomplete service access with a kit installed Unit must beconnected to and operated by a wall thermostat

Hydronic Heat Kit Top View

Hydronic Heat Kit Right View

M983151983140983141983148 H983141983137983156 S983156983137983143983141983155 C983151983151983148 S983156983137983143983141983155 F983137983150 S983152983141983141983140 983151983142 W983145983154983141983155R983141983153983157983145983154983141983140

T983141983149983152L983145983149983145983156983145983150983143

B983137983139983147983148983145983156 D983145983155983152983148983137983161 T983161983152983141S983144983137983152983141 983078

O983154983145983141983150983156983137983156983145983151983150C983151983150983150983141983139983156983145983151983150

2246002 1 1 1 5 No Yes Digital Manual RectHoriz Wired

2246003 2 2 2 7 Yes Yes Digital Manual RectHoriz Wired

2246007 2 2 1 7 Yes Yes Digital Auto-Change RectHoriz Wired

2246008 2 2 1 7 Yes Yes Digital Programmable RectHoriz Wired

DS01E 2 2 2 0 Yes Yes Digital Manual RectHoriz Wireless

Battery powered but has optional hard wire capability Requires DT01G Antennae or operation

Hydronic Heat KitSide View

8182019 mc-dptac

httpslidepdfcomreaderfullmc-dptac 1520

15Specifications and Accessories Catalog

Accessories (cont)P983151983159983141983154 D983151983151983154 K983145983156Vent door will automatically open when unit an is on

Factory Installed Feature Code - D

H983161983140983154983151983150983145983139 V983137983148983158983141983155Water and steam valves are available or use with theHWK03 (water) and HVK03 (steam) heat kits

W983145983154983141983148983141983155983155 RF (R983137983140983145983151 F983154983141983153983157983141983150983139983161) C983151983150983156983154983151983148983155All DigiSmart PTACs come actory-ready to be con-trolledvia wireless RF devices 24 Ghz 802 154 protocol assuresrobust communications and response

W983137983148983148 S983148983141983141983158983141 E983160983156983141983150983155983145983151983150 A983140983137983152983156983141983154 K983145983156983155Room-side extension kits to increase the depth o theexisting sleeve to allow or an industry-standard PTAC tobe installed

C983157983154983156983137983145983150 B983137983142983142983148983141 K983145983156The color matched polymer curtain baffles help toprevent curtains rom alling into the discharge airstream and causing recirculation reducing efficienciesand shortening compressor lie

PDK3A 230208V ndash R-22

PDK4A 265V ndash R-22

PDK3E 230208V ndash R-410A

PDK4E 265V ndash R-410A

VS2WNCA 2-way24VNCSteam VS2WNOA 2-way24VNOSteam VW2WNCA 2-way24VNCEnd Switch

VW2WNOA 2-way24VNOEnd Switch VW3WNC2B 3-way24VNCNOEnd Switch

Poptop Actuator

DS01EThermostat 2-way2 Communications

DD01EOccupancy SensorEMS Activation2

DT01GAntenna RouterFactory InstalledFeature Code - R

GT01GGeneric RadioAntenna Router3

DD01F Door Switch EMS Activation2

DP01G Web-enabled Platorm Server

DL01GWeb-enabled PlatormServer Link BAC-NET capable

DR01G Mesh Repeater1

DL01G-SERIAL

Serial Repeater1

1 Consult Amana Sales representative priorto purchase

2 Requires DT01G or use3 Requires DS01E or use

SECM1001A 15 Extension or 12frac12 Climate Master Sleeve (10 Pack)

SEZA0501A 25 Extension or 11frac12 Zone Air Sleeve (5 pack)

PTCB10B 10 Pack or R-22 units

PTCB10E 10 Pack or R-410A units

8182019 mc-dptac

httpslidepdfcomreaderfullmc-dptac 1620

16 wwwamana-ptaccom

Unit with Accessory Wall Sleeve and Sub-base Accessory

3

11

6- 18 9- 91624 -5 16

40

42

Location of external drain holes on bottom flange of Wall Sleeve

3 Clearance

to side walls

Air Flow

Air Flow

Air Flow

Air Discharge Grille ControlDoor

T983151983152 V983145983141983159

F983154983151983150983156 V98314598314198315958 LCDI CORD SET mdash 230V208V UNIT

58 CORD SET 230V208V UNIT

18 CORD SET 2 65V UNIT

3-14

MIN

2

MAX

2-58

42

16-116

RI GHTLEFT

1 and frac34 Concentric knock-outs back ampbottom o sub-base (electrical only)

R983145983143983144983156 V983145983141983159

2frac34

4

11⅜

983225983219 frasl ₁₆

983225983219 frasl ₁₆ 1⅜

16983225 frasl ₁₆

1⅜Arch Grille

⅞Stamped Grille

14⅛Wall Sleeve

21frac12

7⅜

Optional

Sub-base

HingedControlDoor

15deg

40deg

Air discharge grille is reversible to provideeither 15deg or 40deg discharge angle

frac12 ODCopperDrain Tube

8182019 mc-dptac

httpslidepdfcomreaderfullmc-dptac 1720

17Specifications and Accessories Catalog

Framing or Accessory Wall Sleeve (WS9XX)F983137983155983156983141983150983145983150983143 W983137983148983148 S983148983141983141983158983141When installed in an opening the Wall Sleeve must behorizontally level (side-to-side) and pitched frac14 bubble to the outside

(NOTE To ensure unitrsquos maximum efficiency DO NOT over- or under-pitch)

I983150983155983156983137983148983148983137983156983145983151983150 N9831519831569831419831551 I Sub-base (PTSBE) is installed allow minimum

3frac14 height clearance and maximum 5 heightclearance between wall sleeve and loor allowminimum 2frac34 protrusion rom a inished wallSee Note 4 if using hydronic units

2 Drain Kit (DK900D) shipped separately Can bemounted either right side lef side or bottom osleeve I mounted to bottom o sleeve allow2 height clearance rom loor to bottom o sleeve

3 For UL approval 265V units must use Amanareg brandSub-base (PTSBE) or Amanareg brand Hard WireKit (PSHW04A) Overcurrent protection on 265V unitsmust be by cartridge-style time delay uses whichare included and factory-installed on the Amanareg brand 265V chassis

4 I Hydronic Kit (HWK03 or HVK03) is installedWall Sleeve must extend exactly 3 into the roomrom the inished interior wall I using the Amana reg brand Sub-base (PTSBE) only the minimum3frac14 height clearance between wall sleeve and loor

is permissible Unit must also be operated with aremote-mounted thermostat

5 I Duct Kit (MDK) is installed allow a minimum o2⅜ into the room rom the inished interior wall

MountingHoles(Drilled byInstaller)

PlasticAnchor

Screws

ExpansionAnchor Bolt

Toggle Bolt

Wood Screw

AlternativeFastening Method(Field Supplied)

Wall Sleeve must extend a minimum o frac14 beyond outside wall to allow orproper caulking

FINISHED FLOOR

4 2 1 4

16 14

MIN

MAIN STUD

JACK STUDS

HEADER - 4 x 4 OR

DOUBLE 2x 4 ON EDGE

SUB-FLOOR

CRIPPLE

JACK STUD

ADJUST FRAMING TO

SECURE THIS DIMENSION

Wall sleeve opening height should be squared withwall sleeve opening width

H = 16frac14

W = 42frac14

8182019 mc-dptac

httpslidepdfcomreaderfullmc-dptac 1820

Notes

8182019 mc-dptac

httpslidepdfcomreaderfullmc-dptac 1920

Our continuing commitment to quality products may mean a change in speciications without noticecopy 2015 Goodman Company LP Amana is a registered trademark o Maytag Corporation or its related

companies and is used under license to Goodman Company LP Houston TX USA All rights reserved

Quiet two-an motor system

Energy-eicient perormance

DigiSmartreg wireless controls on select models

Wise DecisionItrsquos an Amanareg brand

8182019 mc-dptac

httpslidepdfcomreaderfullmc-dptac 2020

Our continuing commitment to quality products may mean a change in speciications without notice copy 2015 Goodman Company LPAmana is a registered trademark o Maytag Corporation or its related companies and is used under license to Goodman Company L P

wwwamana-ptaccom

Call your Amana brand PTAC sales representative at 800-647-2982 or complete details

Beore purchasing this appliance read important inormation about its estimated annual energy

consumption yearly operating cost or energy efficiency rating that is available rom your retailer

A legacy o comortThe impeccable reputation oan American original

Amana heating and cooling systems are a part of the

enduring legacy of one of Americarsquos most recognized

and respected brands Originating eight decades ago in

Amana Iowa the brand is synonymous with long-last-

ing premium-quality products mdash from home appliances

to heating and air conditioning equipment Chances

are you and generations beore you have enjoyed the

dependable performance and longevity the Amana

brand continues to deliver

MC-DPTAC 07-15Supersedes 06-15

Page 10: mc-dptac

8182019 mc-dptac

httpslidepdfcomreaderfullmc-dptac 1020

10 wwwamana-ptaccom

Product Speciications PTH Models mdash Reverse-Cycle Heating PerormanceH983141983137983156983145983150983143

C983137983152983137983139983145983156983161983225PTH073G

AXXXPTH093G

AXXXPTH123G

AXXXPTH153G

AXXXPTH074G

AXXXPTH094G

AXXXPTH124G

AXXXPTH154G

AXXX

Voltage 983225 983219 230 208 230 208 230 208 230 208 265 265 265 265

BTUh ⁵ 6800 6800 8300 8100 11500 11300 13800 13600 6800 8300 11400 13700

Amps 983225⁰ 39 39 42 42 58 58 70 70 31 37 50 61

Watts 983225⁰ 585 585 715 700 1085 1035 1350 1330 585 715 1080 1340

COP ⁵ 34 34 34 34 31 32 30 30 34 34 31 30

CFM (Dry) 370 360 370 410 370 360 370 410

COP = Coefficiency o Perormance per AHRI Test Procedures units are rated or capacities and efficiencies

N983151983156983141983155

983225 All 265-volt models must use an Amanareg brand sub-base (PTSB4E) or an Amanareg brand hard-wire kit (PTPWHWK4)983218 Minimum branch circuit ampacity ratings conorm to the National Electric Code however local codes should apply983219 Minimum voltage on 230208-volt models is 197 volts maximum is 253 volts

Minimum voltage on 265-volt models is 239 volts maximum is 292 volts⁴ Overcurrent protection or all units without electric heaters is 15 amps Overcurrent protection on 265-volt models must

be cartridge-style time-delay uses (included and actory-installed on all Amanareg brand 265-volt chassis)⁵ Heating capacity and efficiency based on unit operation without condensate pump unit automatically switches to electric

heat at approximately 24degF outdoor ambient⁶ Speciy two-digit heater kW size to complete model number⁷ R-410A rerigerant used in all systems⁸ All units meet or exceed ASHRAE 901 standards⁹ All units less than 250 volts have a Leak Current Detector Interrupter (LCDI) power cord and meet UL 484 standards983225⁰ Reer to electric heat perormance data or total MCA and recommended overcurrent protection

Amps and Watts notation reers to compressor only

Product Speciications PTC PTH Models mdash Electric Heat Perormance(Primary Heating or PTC Models Auxiliary Heating or PTH Models See below or Power Cord Coniguration)

V983151983148983156983137983143983141E983148983141983139983156983154983145983139H983141983137983156983141983154

S983145983162983141 (983147W)

N983151 983151983142S983156983137983143983141983155

N983151983149983145983150983137983148 H983141983137983156983145983150983143 (BTU983144)T983151983156983137983148

W983137983156983156983155983094T983151983156983137983148 A983149983152983155

M983145983150 C983145983154983139983157983145983156 A983149983152983137983139983145983156983161983218

MOP983092(983137983149983152983155)

P983151983159983141983154C983151983154983140

10486269830911048624V 104862610486241048632V 104862610486301048629V

230208V 15 13 1 5100 4200 - - 1570 1295 68 62 85 15 6-15 P

230208V 25 21 1 8500 6800 - - 2570 2115 112 101 141 15 6-15 P

230208V 35 30 1 12000 9900 - - 3570 2935 155 141 195 20 6-20 P

230208V 50 41 1 17100 14000 - - 5070 4160 221 200 276 30 6-30 P

265V 15 1 - - - - 5100 1570 59 74 15 7-20P

265V 25 1 - - - - 8500 2570 97 122 15 7-20 P

265V 37 1 - - - - 12600 3770 142 179 20 7-20 P265V 5 1 - - - - 17100 5070 192 239 25 7-30 P

N983151983156983141983155983225 All 265-volt models must use an Amanareg brand sub-base (PTSB4E) or an Amanareg brand hard-wire kit (PTPWHWK4)983218 Minimum branch circuit ampacity ratings conorm to the National Electric Code however local codes should apply983219 Minimum voltage on 230208-volt models is 197 volts maximum is 253 volts Minimum voltage on 265-volt models is 239 volts maximum is 292 volts⁴ Overcurrent protection or all units without electric heaters is 15 amps Overcurrent protection on 265-volt models must be cartridge-style

time-delay uses (included and actory-installed on all Amanareg brand 265-volt chassis)⁵ Heating capacity and efficiency based on unit operation without condensate pump unit automatically switches to electric heat at

approximately 24degF outdoor ambient⁶ Total watts or 15000 BTUh models subtract 20 watts or PT070912⁷ Speciy two-digit heater kW size to complete model number⁸ R-410A rerigerant used in all systems⁹ All units meet or exceed ASHRAE 901 standards983225⁰ All units less than 250 volts have a Leak Current Detector Interrupter (LCDI) power cord and meet UL 484 standards

8182019 mc-dptac

httpslidepdfcomreaderfullmc-dptac 1120

11Specifications and Accessories Catalog

AccessoriesW983137983148983148 S983148983141983141983158983141983155All our wall sleeves have industry standard dimensionso 42 wide x 16⅟ ₁₆ high The WS900E SC and INTERNAL14⅛ depth is the industry standard Sleeves maybe shipped separately to allow or installationduring construction

C983151983150983140983141983150983155983137983156983141 D983154983137983145983150 K983145983156Attaches to the wall sleeve base pan or controlledinternal or external disposal o condensate

L983151983159983085V983151983148983156983137983143983141 W983145983154983141 H983137983154983150983141983155983155 K983145983156 (983150983151983156 983155983144983151983159983150)For quick connections o the remote or wiredthermostats wired EMS or ront desk with jumpers andconnectors

R983141983149983151983156983141 E983155983139983157983156983139983144983141983151983150 K983145983156 (983150983151983156 983155983144983151983159983150)Optional kit or use with units controlled via a wiredremote thermostat Covers control touch-pad or wiredthermostat installations

Each ldquoBrdquo kit contains 80 wires and wire nutsenough to attach a thermostat and oneadditional accessory to 10 PTAC units Wirescome in assorted colors or easy attachmentEach ldquoArdquo kit contains 10 Escutcheon plates only

O983157983156983140983151983151983154 G983154983145983148983148983141983155Available in stamped-aluminum or architecturallylouvered or application with an Amana brand WS900Ewall sleeve

AGK Extruded aluminum architectural grille availablewith anodized aluminum inish or a baked-on paintinish or durability Choose rom 3 stock colors or acustom color to blend with your buildingrsquos exteriorcolor scheme Colors include

CB (Clear Anodized) DB (Dark BrownBronze)TB (Stonewood Beige) WB (White)SB (SpecialCustom Colors)

PGK One-piece injection molded grille using a polymerblend o engineered thermoplastic high-impactstrength material with chemical resistance andan exterior UV protective coating

Choose from 3 stock colorsDB (Dark BrownBronze) TB (Stonewood Beige)

WB (White)

S983156983137983150983140983137983154983140983085D983141983152983156983144 S983148983141983141983158983141983155

WS900E-GS Heavy Sound Isolation Insulation Sleeve

WS900E Standard PTAC sleeve

WS900SC Seacoast triple protected

WS900D-INTERNAL

Internal drain only or window-wallinstallations (DK900D sold separately)

E983160983156983154983137 D983141983141983152 S983148983141983141983158983141983155 in several depths orthicker wall installations or special roomconigurations

WS9XXD1 16 to 24 in 1 increments

WS928D1 Extra deep 28

WS930D1 Extra deep 30

WS936D1 Extra deep 36

WS9XXD1-Interna

Extra deep Internal drain onlyor window-wall installations(DK900D sold separately) 1 4

⅛ 4 2

1 6

1

1 6

S983156983137983150983140983137983154983140 O983157983156983140983151983151983154 G983154983145983148983148983141

SGK01B Single Pack

SGK01TB Stonewood Beige

A983154983139983144983145983156983141983139983156983157983154983137983148 O983157983156983140983151983151983154 G983154983145983148983148983141

AGK01CB Anodized Aluminum

AGK01DB Dark BronzeBrown

AGK01TB Stonewood Beige

AGK01WB Amana White

AGK01SB Custom Colors

PGK01DB Dark BronzeBrown

PGK01TB Stonewood Beige

PGK01WB Amana White

AGKor

PGK

SGK

DK900DCondensate Drain Kit(use with WS900E)

DK9001DCondensate Drain Kit(use with WS900B)

DK900D

PWHK01C Wire Harness Kit

REK10BRemote Escutcheon Kit(10-pack)

REK10A Remote Escutcheon Plates

8182019 mc-dptac

httpslidepdfcomreaderfullmc-dptac 1220

12 wwwamana-ptaccom

Accessories (cont)S983157983138983085983138983137983155983141 K983145983156The ully skirted sub-base conceals wiring whileproviding strong support i needed Plug-in receptacleand ield-wiring access speeds installation Electricalaccessories such as use holders circuit breakers anddisconnect switches meet NEC requirements

L983141983158983141983148983145983150983143 L983141983143983155Gives wall sleeve ront support and helps to level theunit or installation

H983137983154983140983085983159983145983154983141 K983145983156983155Used to permanently wire to the chassis when astandard sub-base and power cord are not utilized

F983137983139983156983151983154983161 I983150983155983156983137983148983148983141983140 Feature Code - W

P983151983159983141983154 D983145983155983139983151983150983150983141983139983156 S983159983145983156983139983144The PSHWA power disconnect switch can be usedor 265-volt or 230208-volt physical disconnectwhere required by local codes The switch is ratedat 30-amp capacity The switch is or use with andAmanareg brand standard sub-bases or PTPWHWK4Hard Wire Kit

F983157983155983141 H983151983148983140983141983154 K983145983156Cartridge-style uses can be installed in the useholder or use in the sub-base or chassis Available in15 20 and 30 amp (included on 265-volt unit)

C983145983154983139983157983145983156 B983154983141983137983147983141983154 K983145983156 (983090983091983088983090983088983096V 983151983150983148983161)The circuit breaker kit available in 15 20 or 30 ampcan be used with Amana brand sub-bases It givesovercurrent protection and its location allows you toturn the unit on or off without tools

PTSB215E 115V15A

PTSB320E 230208V 1520A

PTSB330E 230208V 30A

PTSB420E 265V 1520A

PTSB430E 265V 25A

PTSB000E Non-electrical

LL2B Leveling legs or WS9 sleeves

PTPWHWK4 Armored Cable ndash all voltages

PTQC3A Quick Connect ndash 230208V

PTQC4A Quick Connect ndash 265 amp 115 V

PSHW03A 230208V

PSHW04A 265V

FHK315E 230208V 15A

FHK315E 230208V 15A (R-410A)

FHK320C 230208V 20A

FHK320E 230208V 20A (R-410A)

FHK330C 230208V 30A

FHK330E 230208V 30A (R-410A)

CBK15C 15 amp Circuit Breaker Kit

CBK20C 20 amp Circuit Breaker Kit

CBK30C 30 amp Circuit Breaker Kit

8182019 mc-dptac

httpslidepdfcomreaderfullmc-dptac 1320

13Specifications and Accessories Catalog

Accessories (cont)

P983151983159983141983154 V983141983150983156 K983145983156Installation o Power Vent increases CFM up toapproximately 95 Vent door will automatically closewhen unit an is off

F983137983139983156983151983154983161 I983150983155983156983137983148983148983141983140 Feature Code - VR-410A models must have these kits installed atthe actory

C983151983150983140983141983150983155983141983154 B983137983142983142983148983141 K983145983156For use on non-baffled grilles These delectors directthe air in toward the center and away rom the inlet toprevent recirculation o the hot condenser air

S983157983138983085983138983137983155983141 E983160983156983141983150983155983145983151983150 C983151983158983141983154 K983145983156Converts older 30-amp sub-bases to allow or installationo the larger 30-amp LCDI power cord and plugs

S983141983139983157983154983145983156983161 K983141983161 L983151983139983147983155In conjunction with the tamper-resistant ront theinstallation o Amanareg brand security key locks preventstampering o the controls used to set temperature heatingand cooling unctions UL approved or institutionaluse only

C983151983150983140983141983150983155983137983156983141 R983141983149983151983158983137983148 P983157983149983152Can be ield-installed Assists in removing condensatedeveloped by heat pump operation and transers it to

indoor coil to dissipate into room while adding humidityto the room

F983137983139983156983151983154983161 I983150983155983156983137983148983148983141983140 Feature Code - P

PVK3A 230208V ndash R-22

PVK4A 265V ndash R-22

D983157983139983156 E983160983156983141983150983155983145983151983150 K983145983156Extends air distribution to an adjoining room Consistsof a main duct for the room of origin and an extensionduct to reach the adjoining room and terminal ductPTDK01A allows for the ldquoBrdquo series unit to work with theldquoArdquo series duct kits

MDK02B Main Duct ndash R-22

MDK01E Main Duct ndash R-410A

EDK02B 42 Extension Duct

TRANSITION BAFFLES

Main Duct Kit

TDK02B Terminal Duct

PTDK01A Transition Duct Only ndash R-22

PTDK01E Transition Duct Only ndash R-410A

Extension Duct Kit

Terminal Duct Kit

DGK1B Condenser Baffle Kit

SBEC10A 10 Pack

Basepan

Condenser

Condenser Baffles

KL03B Security Key Lock (R-22)

KL03E Security Key Lock (R-410A)

CDP302 230208V ndash R-22

CDP402 265V ndash R-22

CDP303E 230208V ndash R-410A

8182019 mc-dptac

httpslidepdfcomreaderfullmc-dptac 1420

14 wwwamana-ptaccom

Accessories (cont)

HWK03B Hydronic Water Kit ndash R-22

HVK03B Hydronic Steam Kit ndash R-22

HWK03E Hydronic Water Kit ndash R-410A

HVK03E Hydronic Steam Kit ndash R-410A

ThermostatsThe ollowing thermostats offer remote control Any thermostat other than those listed must be submitted to Goodman Company LPor approval prior to use

H983161983140983154983151983150983145983139 H983141983137983156 K983145983156Add-on kits it all units allowing the addition o hydronicwater or hydronic steam heat to cooling and heating unitsThe kits eature lef- or right-hand piping Unit retainscomplete service access with a kit installed Unit must beconnected to and operated by a wall thermostat

Hydronic Heat Kit Top View

Hydronic Heat Kit Right View

M983151983140983141983148 H983141983137983156 S983156983137983143983141983155 C983151983151983148 S983156983137983143983141983155 F983137983150 S983152983141983141983140 983151983142 W983145983154983141983155R983141983153983157983145983154983141983140

T983141983149983152L983145983149983145983156983145983150983143

B983137983139983147983148983145983156 D983145983155983152983148983137983161 T983161983152983141S983144983137983152983141 983078

O983154983145983141983150983156983137983156983145983151983150C983151983150983150983141983139983156983145983151983150

2246002 1 1 1 5 No Yes Digital Manual RectHoriz Wired

2246003 2 2 2 7 Yes Yes Digital Manual RectHoriz Wired

2246007 2 2 1 7 Yes Yes Digital Auto-Change RectHoriz Wired

2246008 2 2 1 7 Yes Yes Digital Programmable RectHoriz Wired

DS01E 2 2 2 0 Yes Yes Digital Manual RectHoriz Wireless

Battery powered but has optional hard wire capability Requires DT01G Antennae or operation

Hydronic Heat KitSide View

8182019 mc-dptac

httpslidepdfcomreaderfullmc-dptac 1520

15Specifications and Accessories Catalog

Accessories (cont)P983151983159983141983154 D983151983151983154 K983145983156Vent door will automatically open when unit an is on

Factory Installed Feature Code - D

H983161983140983154983151983150983145983139 V983137983148983158983141983155Water and steam valves are available or use with theHWK03 (water) and HVK03 (steam) heat kits

W983145983154983141983148983141983155983155 RF (R983137983140983145983151 F983154983141983153983157983141983150983139983161) C983151983150983156983154983151983148983155All DigiSmart PTACs come actory-ready to be con-trolledvia wireless RF devices 24 Ghz 802 154 protocol assuresrobust communications and response

W983137983148983148 S983148983141983141983158983141 E983160983156983141983150983155983145983151983150 A983140983137983152983156983141983154 K983145983156983155Room-side extension kits to increase the depth o theexisting sleeve to allow or an industry-standard PTAC tobe installed

C983157983154983156983137983145983150 B983137983142983142983148983141 K983145983156The color matched polymer curtain baffles help toprevent curtains rom alling into the discharge airstream and causing recirculation reducing efficienciesand shortening compressor lie

PDK3A 230208V ndash R-22

PDK4A 265V ndash R-22

PDK3E 230208V ndash R-410A

PDK4E 265V ndash R-410A

VS2WNCA 2-way24VNCSteam VS2WNOA 2-way24VNOSteam VW2WNCA 2-way24VNCEnd Switch

VW2WNOA 2-way24VNOEnd Switch VW3WNC2B 3-way24VNCNOEnd Switch

Poptop Actuator

DS01EThermostat 2-way2 Communications

DD01EOccupancy SensorEMS Activation2

DT01GAntenna RouterFactory InstalledFeature Code - R

GT01GGeneric RadioAntenna Router3

DD01F Door Switch EMS Activation2

DP01G Web-enabled Platorm Server

DL01GWeb-enabled PlatormServer Link BAC-NET capable

DR01G Mesh Repeater1

DL01G-SERIAL

Serial Repeater1

1 Consult Amana Sales representative priorto purchase

2 Requires DT01G or use3 Requires DS01E or use

SECM1001A 15 Extension or 12frac12 Climate Master Sleeve (10 Pack)

SEZA0501A 25 Extension or 11frac12 Zone Air Sleeve (5 pack)

PTCB10B 10 Pack or R-22 units

PTCB10E 10 Pack or R-410A units

8182019 mc-dptac

httpslidepdfcomreaderfullmc-dptac 1620

16 wwwamana-ptaccom

Unit with Accessory Wall Sleeve and Sub-base Accessory

3

11

6- 18 9- 91624 -5 16

40

42

Location of external drain holes on bottom flange of Wall Sleeve

3 Clearance

to side walls

Air Flow

Air Flow

Air Flow

Air Discharge Grille ControlDoor

T983151983152 V983145983141983159

F983154983151983150983156 V98314598314198315958 LCDI CORD SET mdash 230V208V UNIT

58 CORD SET 230V208V UNIT

18 CORD SET 2 65V UNIT

3-14

MIN

2

MAX

2-58

42

16-116

RI GHTLEFT

1 and frac34 Concentric knock-outs back ampbottom o sub-base (electrical only)

R983145983143983144983156 V983145983141983159

2frac34

4

11⅜

983225983219 frasl ₁₆

983225983219 frasl ₁₆ 1⅜

16983225 frasl ₁₆

1⅜Arch Grille

⅞Stamped Grille

14⅛Wall Sleeve

21frac12

7⅜

Optional

Sub-base

HingedControlDoor

15deg

40deg

Air discharge grille is reversible to provideeither 15deg or 40deg discharge angle

frac12 ODCopperDrain Tube

8182019 mc-dptac

httpslidepdfcomreaderfullmc-dptac 1720

17Specifications and Accessories Catalog

Framing or Accessory Wall Sleeve (WS9XX)F983137983155983156983141983150983145983150983143 W983137983148983148 S983148983141983141983158983141When installed in an opening the Wall Sleeve must behorizontally level (side-to-side) and pitched frac14 bubble to the outside

(NOTE To ensure unitrsquos maximum efficiency DO NOT over- or under-pitch)

I983150983155983156983137983148983148983137983156983145983151983150 N9831519831569831419831551 I Sub-base (PTSBE) is installed allow minimum

3frac14 height clearance and maximum 5 heightclearance between wall sleeve and loor allowminimum 2frac34 protrusion rom a inished wallSee Note 4 if using hydronic units

2 Drain Kit (DK900D) shipped separately Can bemounted either right side lef side or bottom osleeve I mounted to bottom o sleeve allow2 height clearance rom loor to bottom o sleeve

3 For UL approval 265V units must use Amanareg brandSub-base (PTSBE) or Amanareg brand Hard WireKit (PSHW04A) Overcurrent protection on 265V unitsmust be by cartridge-style time delay uses whichare included and factory-installed on the Amanareg brand 265V chassis

4 I Hydronic Kit (HWK03 or HVK03) is installedWall Sleeve must extend exactly 3 into the roomrom the inished interior wall I using the Amana reg brand Sub-base (PTSBE) only the minimum3frac14 height clearance between wall sleeve and loor

is permissible Unit must also be operated with aremote-mounted thermostat

5 I Duct Kit (MDK) is installed allow a minimum o2⅜ into the room rom the inished interior wall

MountingHoles(Drilled byInstaller)

PlasticAnchor

Screws

ExpansionAnchor Bolt

Toggle Bolt

Wood Screw

AlternativeFastening Method(Field Supplied)

Wall Sleeve must extend a minimum o frac14 beyond outside wall to allow orproper caulking

FINISHED FLOOR

4 2 1 4

16 14

MIN

MAIN STUD

JACK STUDS

HEADER - 4 x 4 OR

DOUBLE 2x 4 ON EDGE

SUB-FLOOR

CRIPPLE

JACK STUD

ADJUST FRAMING TO

SECURE THIS DIMENSION

Wall sleeve opening height should be squared withwall sleeve opening width

H = 16frac14

W = 42frac14

8182019 mc-dptac

httpslidepdfcomreaderfullmc-dptac 1820

Notes

8182019 mc-dptac

httpslidepdfcomreaderfullmc-dptac 1920

Our continuing commitment to quality products may mean a change in speciications without noticecopy 2015 Goodman Company LP Amana is a registered trademark o Maytag Corporation or its related

companies and is used under license to Goodman Company LP Houston TX USA All rights reserved

Quiet two-an motor system

Energy-eicient perormance

DigiSmartreg wireless controls on select models

Wise DecisionItrsquos an Amanareg brand

8182019 mc-dptac

httpslidepdfcomreaderfullmc-dptac 2020

Our continuing commitment to quality products may mean a change in speciications without notice copy 2015 Goodman Company LPAmana is a registered trademark o Maytag Corporation or its related companies and is used under license to Goodman Company L P

wwwamana-ptaccom

Call your Amana brand PTAC sales representative at 800-647-2982 or complete details

Beore purchasing this appliance read important inormation about its estimated annual energy

consumption yearly operating cost or energy efficiency rating that is available rom your retailer

A legacy o comortThe impeccable reputation oan American original

Amana heating and cooling systems are a part of the

enduring legacy of one of Americarsquos most recognized

and respected brands Originating eight decades ago in

Amana Iowa the brand is synonymous with long-last-

ing premium-quality products mdash from home appliances

to heating and air conditioning equipment Chances

are you and generations beore you have enjoyed the

dependable performance and longevity the Amana

brand continues to deliver

MC-DPTAC 07-15Supersedes 06-15

Page 11: mc-dptac

8182019 mc-dptac

httpslidepdfcomreaderfullmc-dptac 1120

11Specifications and Accessories Catalog

AccessoriesW983137983148983148 S983148983141983141983158983141983155All our wall sleeves have industry standard dimensionso 42 wide x 16⅟ ₁₆ high The WS900E SC and INTERNAL14⅛ depth is the industry standard Sleeves maybe shipped separately to allow or installationduring construction

C983151983150983140983141983150983155983137983156983141 D983154983137983145983150 K983145983156Attaches to the wall sleeve base pan or controlledinternal or external disposal o condensate

L983151983159983085V983151983148983156983137983143983141 W983145983154983141 H983137983154983150983141983155983155 K983145983156 (983150983151983156 983155983144983151983159983150)For quick connections o the remote or wiredthermostats wired EMS or ront desk with jumpers andconnectors

R983141983149983151983156983141 E983155983139983157983156983139983144983141983151983150 K983145983156 (983150983151983156 983155983144983151983159983150)Optional kit or use with units controlled via a wiredremote thermostat Covers control touch-pad or wiredthermostat installations

Each ldquoBrdquo kit contains 80 wires and wire nutsenough to attach a thermostat and oneadditional accessory to 10 PTAC units Wirescome in assorted colors or easy attachmentEach ldquoArdquo kit contains 10 Escutcheon plates only

O983157983156983140983151983151983154 G983154983145983148983148983141983155Available in stamped-aluminum or architecturallylouvered or application with an Amana brand WS900Ewall sleeve

AGK Extruded aluminum architectural grille availablewith anodized aluminum inish or a baked-on paintinish or durability Choose rom 3 stock colors or acustom color to blend with your buildingrsquos exteriorcolor scheme Colors include

CB (Clear Anodized) DB (Dark BrownBronze)TB (Stonewood Beige) WB (White)SB (SpecialCustom Colors)

PGK One-piece injection molded grille using a polymerblend o engineered thermoplastic high-impactstrength material with chemical resistance andan exterior UV protective coating

Choose from 3 stock colorsDB (Dark BrownBronze) TB (Stonewood Beige)

WB (White)

S983156983137983150983140983137983154983140983085D983141983152983156983144 S983148983141983141983158983141983155

WS900E-GS Heavy Sound Isolation Insulation Sleeve

WS900E Standard PTAC sleeve

WS900SC Seacoast triple protected

WS900D-INTERNAL

Internal drain only or window-wallinstallations (DK900D sold separately)

E983160983156983154983137 D983141983141983152 S983148983141983141983158983141983155 in several depths orthicker wall installations or special roomconigurations

WS9XXD1 16 to 24 in 1 increments

WS928D1 Extra deep 28

WS930D1 Extra deep 30

WS936D1 Extra deep 36

WS9XXD1-Interna

Extra deep Internal drain onlyor window-wall installations(DK900D sold separately) 1 4

⅛ 4 2

1 6

1

1 6

S983156983137983150983140983137983154983140 O983157983156983140983151983151983154 G983154983145983148983148983141

SGK01B Single Pack

SGK01TB Stonewood Beige

A983154983139983144983145983156983141983139983156983157983154983137983148 O983157983156983140983151983151983154 G983154983145983148983148983141

AGK01CB Anodized Aluminum

AGK01DB Dark BronzeBrown

AGK01TB Stonewood Beige

AGK01WB Amana White

AGK01SB Custom Colors

PGK01DB Dark BronzeBrown

PGK01TB Stonewood Beige

PGK01WB Amana White

AGKor

PGK

SGK

DK900DCondensate Drain Kit(use with WS900E)

DK9001DCondensate Drain Kit(use with WS900B)

DK900D

PWHK01C Wire Harness Kit

REK10BRemote Escutcheon Kit(10-pack)

REK10A Remote Escutcheon Plates

8182019 mc-dptac

httpslidepdfcomreaderfullmc-dptac 1220

12 wwwamana-ptaccom

Accessories (cont)S983157983138983085983138983137983155983141 K983145983156The ully skirted sub-base conceals wiring whileproviding strong support i needed Plug-in receptacleand ield-wiring access speeds installation Electricalaccessories such as use holders circuit breakers anddisconnect switches meet NEC requirements

L983141983158983141983148983145983150983143 L983141983143983155Gives wall sleeve ront support and helps to level theunit or installation

H983137983154983140983085983159983145983154983141 K983145983156983155Used to permanently wire to the chassis when astandard sub-base and power cord are not utilized

F983137983139983156983151983154983161 I983150983155983156983137983148983148983141983140 Feature Code - W

P983151983159983141983154 D983145983155983139983151983150983150983141983139983156 S983159983145983156983139983144The PSHWA power disconnect switch can be usedor 265-volt or 230208-volt physical disconnectwhere required by local codes The switch is ratedat 30-amp capacity The switch is or use with andAmanareg brand standard sub-bases or PTPWHWK4Hard Wire Kit

F983157983155983141 H983151983148983140983141983154 K983145983156Cartridge-style uses can be installed in the useholder or use in the sub-base or chassis Available in15 20 and 30 amp (included on 265-volt unit)

C983145983154983139983157983145983156 B983154983141983137983147983141983154 K983145983156 (983090983091983088983090983088983096V 983151983150983148983161)The circuit breaker kit available in 15 20 or 30 ampcan be used with Amana brand sub-bases It givesovercurrent protection and its location allows you toturn the unit on or off without tools

PTSB215E 115V15A

PTSB320E 230208V 1520A

PTSB330E 230208V 30A

PTSB420E 265V 1520A

PTSB430E 265V 25A

PTSB000E Non-electrical

LL2B Leveling legs or WS9 sleeves

PTPWHWK4 Armored Cable ndash all voltages

PTQC3A Quick Connect ndash 230208V

PTQC4A Quick Connect ndash 265 amp 115 V

PSHW03A 230208V

PSHW04A 265V

FHK315E 230208V 15A

FHK315E 230208V 15A (R-410A)

FHK320C 230208V 20A

FHK320E 230208V 20A (R-410A)

FHK330C 230208V 30A

FHK330E 230208V 30A (R-410A)

CBK15C 15 amp Circuit Breaker Kit

CBK20C 20 amp Circuit Breaker Kit

CBK30C 30 amp Circuit Breaker Kit

8182019 mc-dptac

httpslidepdfcomreaderfullmc-dptac 1320

13Specifications and Accessories Catalog

Accessories (cont)

P983151983159983141983154 V983141983150983156 K983145983156Installation o Power Vent increases CFM up toapproximately 95 Vent door will automatically closewhen unit an is off

F983137983139983156983151983154983161 I983150983155983156983137983148983148983141983140 Feature Code - VR-410A models must have these kits installed atthe actory

C983151983150983140983141983150983155983141983154 B983137983142983142983148983141 K983145983156For use on non-baffled grilles These delectors directthe air in toward the center and away rom the inlet toprevent recirculation o the hot condenser air

S983157983138983085983138983137983155983141 E983160983156983141983150983155983145983151983150 C983151983158983141983154 K983145983156Converts older 30-amp sub-bases to allow or installationo the larger 30-amp LCDI power cord and plugs

S983141983139983157983154983145983156983161 K983141983161 L983151983139983147983155In conjunction with the tamper-resistant ront theinstallation o Amanareg brand security key locks preventstampering o the controls used to set temperature heatingand cooling unctions UL approved or institutionaluse only

C983151983150983140983141983150983155983137983156983141 R983141983149983151983158983137983148 P983157983149983152Can be ield-installed Assists in removing condensatedeveloped by heat pump operation and transers it to

indoor coil to dissipate into room while adding humidityto the room

F983137983139983156983151983154983161 I983150983155983156983137983148983148983141983140 Feature Code - P

PVK3A 230208V ndash R-22

PVK4A 265V ndash R-22

D983157983139983156 E983160983156983141983150983155983145983151983150 K983145983156Extends air distribution to an adjoining room Consistsof a main duct for the room of origin and an extensionduct to reach the adjoining room and terminal ductPTDK01A allows for the ldquoBrdquo series unit to work with theldquoArdquo series duct kits

MDK02B Main Duct ndash R-22

MDK01E Main Duct ndash R-410A

EDK02B 42 Extension Duct

TRANSITION BAFFLES

Main Duct Kit

TDK02B Terminal Duct

PTDK01A Transition Duct Only ndash R-22

PTDK01E Transition Duct Only ndash R-410A

Extension Duct Kit

Terminal Duct Kit

DGK1B Condenser Baffle Kit

SBEC10A 10 Pack

Basepan

Condenser

Condenser Baffles

KL03B Security Key Lock (R-22)

KL03E Security Key Lock (R-410A)

CDP302 230208V ndash R-22

CDP402 265V ndash R-22

CDP303E 230208V ndash R-410A

8182019 mc-dptac

httpslidepdfcomreaderfullmc-dptac 1420

14 wwwamana-ptaccom

Accessories (cont)

HWK03B Hydronic Water Kit ndash R-22

HVK03B Hydronic Steam Kit ndash R-22

HWK03E Hydronic Water Kit ndash R-410A

HVK03E Hydronic Steam Kit ndash R-410A

ThermostatsThe ollowing thermostats offer remote control Any thermostat other than those listed must be submitted to Goodman Company LPor approval prior to use

H983161983140983154983151983150983145983139 H983141983137983156 K983145983156Add-on kits it all units allowing the addition o hydronicwater or hydronic steam heat to cooling and heating unitsThe kits eature lef- or right-hand piping Unit retainscomplete service access with a kit installed Unit must beconnected to and operated by a wall thermostat

Hydronic Heat Kit Top View

Hydronic Heat Kit Right View

M983151983140983141983148 H983141983137983156 S983156983137983143983141983155 C983151983151983148 S983156983137983143983141983155 F983137983150 S983152983141983141983140 983151983142 W983145983154983141983155R983141983153983157983145983154983141983140

T983141983149983152L983145983149983145983156983145983150983143

B983137983139983147983148983145983156 D983145983155983152983148983137983161 T983161983152983141S983144983137983152983141 983078

O983154983145983141983150983156983137983156983145983151983150C983151983150983150983141983139983156983145983151983150

2246002 1 1 1 5 No Yes Digital Manual RectHoriz Wired

2246003 2 2 2 7 Yes Yes Digital Manual RectHoriz Wired

2246007 2 2 1 7 Yes Yes Digital Auto-Change RectHoriz Wired

2246008 2 2 1 7 Yes Yes Digital Programmable RectHoriz Wired

DS01E 2 2 2 0 Yes Yes Digital Manual RectHoriz Wireless

Battery powered but has optional hard wire capability Requires DT01G Antennae or operation

Hydronic Heat KitSide View

8182019 mc-dptac

httpslidepdfcomreaderfullmc-dptac 1520

15Specifications and Accessories Catalog

Accessories (cont)P983151983159983141983154 D983151983151983154 K983145983156Vent door will automatically open when unit an is on

Factory Installed Feature Code - D

H983161983140983154983151983150983145983139 V983137983148983158983141983155Water and steam valves are available or use with theHWK03 (water) and HVK03 (steam) heat kits

W983145983154983141983148983141983155983155 RF (R983137983140983145983151 F983154983141983153983157983141983150983139983161) C983151983150983156983154983151983148983155All DigiSmart PTACs come actory-ready to be con-trolledvia wireless RF devices 24 Ghz 802 154 protocol assuresrobust communications and response

W983137983148983148 S983148983141983141983158983141 E983160983156983141983150983155983145983151983150 A983140983137983152983156983141983154 K983145983156983155Room-side extension kits to increase the depth o theexisting sleeve to allow or an industry-standard PTAC tobe installed

C983157983154983156983137983145983150 B983137983142983142983148983141 K983145983156The color matched polymer curtain baffles help toprevent curtains rom alling into the discharge airstream and causing recirculation reducing efficienciesand shortening compressor lie

PDK3A 230208V ndash R-22

PDK4A 265V ndash R-22

PDK3E 230208V ndash R-410A

PDK4E 265V ndash R-410A

VS2WNCA 2-way24VNCSteam VS2WNOA 2-way24VNOSteam VW2WNCA 2-way24VNCEnd Switch

VW2WNOA 2-way24VNOEnd Switch VW3WNC2B 3-way24VNCNOEnd Switch

Poptop Actuator

DS01EThermostat 2-way2 Communications

DD01EOccupancy SensorEMS Activation2

DT01GAntenna RouterFactory InstalledFeature Code - R

GT01GGeneric RadioAntenna Router3

DD01F Door Switch EMS Activation2

DP01G Web-enabled Platorm Server

DL01GWeb-enabled PlatormServer Link BAC-NET capable

DR01G Mesh Repeater1

DL01G-SERIAL

Serial Repeater1

1 Consult Amana Sales representative priorto purchase

2 Requires DT01G or use3 Requires DS01E or use

SECM1001A 15 Extension or 12frac12 Climate Master Sleeve (10 Pack)

SEZA0501A 25 Extension or 11frac12 Zone Air Sleeve (5 pack)

PTCB10B 10 Pack or R-22 units

PTCB10E 10 Pack or R-410A units

8182019 mc-dptac

httpslidepdfcomreaderfullmc-dptac 1620

16 wwwamana-ptaccom

Unit with Accessory Wall Sleeve and Sub-base Accessory

3

11

6- 18 9- 91624 -5 16

40

42

Location of external drain holes on bottom flange of Wall Sleeve

3 Clearance

to side walls

Air Flow

Air Flow

Air Flow

Air Discharge Grille ControlDoor

T983151983152 V983145983141983159

F983154983151983150983156 V98314598314198315958 LCDI CORD SET mdash 230V208V UNIT

58 CORD SET 230V208V UNIT

18 CORD SET 2 65V UNIT

3-14

MIN

2

MAX

2-58

42

16-116

RI GHTLEFT

1 and frac34 Concentric knock-outs back ampbottom o sub-base (electrical only)

R983145983143983144983156 V983145983141983159

2frac34

4

11⅜

983225983219 frasl ₁₆

983225983219 frasl ₁₆ 1⅜

16983225 frasl ₁₆

1⅜Arch Grille

⅞Stamped Grille

14⅛Wall Sleeve

21frac12

7⅜

Optional

Sub-base

HingedControlDoor

15deg

40deg

Air discharge grille is reversible to provideeither 15deg or 40deg discharge angle

frac12 ODCopperDrain Tube

8182019 mc-dptac

httpslidepdfcomreaderfullmc-dptac 1720

17Specifications and Accessories Catalog

Framing or Accessory Wall Sleeve (WS9XX)F983137983155983156983141983150983145983150983143 W983137983148983148 S983148983141983141983158983141When installed in an opening the Wall Sleeve must behorizontally level (side-to-side) and pitched frac14 bubble to the outside

(NOTE To ensure unitrsquos maximum efficiency DO NOT over- or under-pitch)

I983150983155983156983137983148983148983137983156983145983151983150 N9831519831569831419831551 I Sub-base (PTSBE) is installed allow minimum

3frac14 height clearance and maximum 5 heightclearance between wall sleeve and loor allowminimum 2frac34 protrusion rom a inished wallSee Note 4 if using hydronic units

2 Drain Kit (DK900D) shipped separately Can bemounted either right side lef side or bottom osleeve I mounted to bottom o sleeve allow2 height clearance rom loor to bottom o sleeve

3 For UL approval 265V units must use Amanareg brandSub-base (PTSBE) or Amanareg brand Hard WireKit (PSHW04A) Overcurrent protection on 265V unitsmust be by cartridge-style time delay uses whichare included and factory-installed on the Amanareg brand 265V chassis

4 I Hydronic Kit (HWK03 or HVK03) is installedWall Sleeve must extend exactly 3 into the roomrom the inished interior wall I using the Amana reg brand Sub-base (PTSBE) only the minimum3frac14 height clearance between wall sleeve and loor

is permissible Unit must also be operated with aremote-mounted thermostat

5 I Duct Kit (MDK) is installed allow a minimum o2⅜ into the room rom the inished interior wall

MountingHoles(Drilled byInstaller)

PlasticAnchor

Screws

ExpansionAnchor Bolt

Toggle Bolt

Wood Screw

AlternativeFastening Method(Field Supplied)

Wall Sleeve must extend a minimum o frac14 beyond outside wall to allow orproper caulking

FINISHED FLOOR

4 2 1 4

16 14

MIN

MAIN STUD

JACK STUDS

HEADER - 4 x 4 OR

DOUBLE 2x 4 ON EDGE

SUB-FLOOR

CRIPPLE

JACK STUD

ADJUST FRAMING TO

SECURE THIS DIMENSION

Wall sleeve opening height should be squared withwall sleeve opening width

H = 16frac14

W = 42frac14

8182019 mc-dptac

httpslidepdfcomreaderfullmc-dptac 1820

Notes

8182019 mc-dptac

httpslidepdfcomreaderfullmc-dptac 1920

Our continuing commitment to quality products may mean a change in speciications without noticecopy 2015 Goodman Company LP Amana is a registered trademark o Maytag Corporation or its related

companies and is used under license to Goodman Company LP Houston TX USA All rights reserved

Quiet two-an motor system

Energy-eicient perormance

DigiSmartreg wireless controls on select models

Wise DecisionItrsquos an Amanareg brand

8182019 mc-dptac

httpslidepdfcomreaderfullmc-dptac 2020

Our continuing commitment to quality products may mean a change in speciications without notice copy 2015 Goodman Company LPAmana is a registered trademark o Maytag Corporation or its related companies and is used under license to Goodman Company L P

wwwamana-ptaccom

Call your Amana brand PTAC sales representative at 800-647-2982 or complete details

Beore purchasing this appliance read important inormation about its estimated annual energy

consumption yearly operating cost or energy efficiency rating that is available rom your retailer

A legacy o comortThe impeccable reputation oan American original

Amana heating and cooling systems are a part of the

enduring legacy of one of Americarsquos most recognized

and respected brands Originating eight decades ago in

Amana Iowa the brand is synonymous with long-last-

ing premium-quality products mdash from home appliances

to heating and air conditioning equipment Chances

are you and generations beore you have enjoyed the

dependable performance and longevity the Amana

brand continues to deliver

MC-DPTAC 07-15Supersedes 06-15

Page 12: mc-dptac

8182019 mc-dptac

httpslidepdfcomreaderfullmc-dptac 1220

12 wwwamana-ptaccom

Accessories (cont)S983157983138983085983138983137983155983141 K983145983156The ully skirted sub-base conceals wiring whileproviding strong support i needed Plug-in receptacleand ield-wiring access speeds installation Electricalaccessories such as use holders circuit breakers anddisconnect switches meet NEC requirements

L983141983158983141983148983145983150983143 L983141983143983155Gives wall sleeve ront support and helps to level theunit or installation

H983137983154983140983085983159983145983154983141 K983145983156983155Used to permanently wire to the chassis when astandard sub-base and power cord are not utilized

F983137983139983156983151983154983161 I983150983155983156983137983148983148983141983140 Feature Code - W

P983151983159983141983154 D983145983155983139983151983150983150983141983139983156 S983159983145983156983139983144The PSHWA power disconnect switch can be usedor 265-volt or 230208-volt physical disconnectwhere required by local codes The switch is ratedat 30-amp capacity The switch is or use with andAmanareg brand standard sub-bases or PTPWHWK4Hard Wire Kit

F983157983155983141 H983151983148983140983141983154 K983145983156Cartridge-style uses can be installed in the useholder or use in the sub-base or chassis Available in15 20 and 30 amp (included on 265-volt unit)

C983145983154983139983157983145983156 B983154983141983137983147983141983154 K983145983156 (983090983091983088983090983088983096V 983151983150983148983161)The circuit breaker kit available in 15 20 or 30 ampcan be used with Amana brand sub-bases It givesovercurrent protection and its location allows you toturn the unit on or off without tools

PTSB215E 115V15A

PTSB320E 230208V 1520A

PTSB330E 230208V 30A

PTSB420E 265V 1520A

PTSB430E 265V 25A

PTSB000E Non-electrical

LL2B Leveling legs or WS9 sleeves

PTPWHWK4 Armored Cable ndash all voltages

PTQC3A Quick Connect ndash 230208V

PTQC4A Quick Connect ndash 265 amp 115 V

PSHW03A 230208V

PSHW04A 265V

FHK315E 230208V 15A

FHK315E 230208V 15A (R-410A)

FHK320C 230208V 20A

FHK320E 230208V 20A (R-410A)

FHK330C 230208V 30A

FHK330E 230208V 30A (R-410A)

CBK15C 15 amp Circuit Breaker Kit

CBK20C 20 amp Circuit Breaker Kit

CBK30C 30 amp Circuit Breaker Kit

8182019 mc-dptac

httpslidepdfcomreaderfullmc-dptac 1320

13Specifications and Accessories Catalog

Accessories (cont)

P983151983159983141983154 V983141983150983156 K983145983156Installation o Power Vent increases CFM up toapproximately 95 Vent door will automatically closewhen unit an is off

F983137983139983156983151983154983161 I983150983155983156983137983148983148983141983140 Feature Code - VR-410A models must have these kits installed atthe actory

C983151983150983140983141983150983155983141983154 B983137983142983142983148983141 K983145983156For use on non-baffled grilles These delectors directthe air in toward the center and away rom the inlet toprevent recirculation o the hot condenser air

S983157983138983085983138983137983155983141 E983160983156983141983150983155983145983151983150 C983151983158983141983154 K983145983156Converts older 30-amp sub-bases to allow or installationo the larger 30-amp LCDI power cord and plugs

S983141983139983157983154983145983156983161 K983141983161 L983151983139983147983155In conjunction with the tamper-resistant ront theinstallation o Amanareg brand security key locks preventstampering o the controls used to set temperature heatingand cooling unctions UL approved or institutionaluse only

C983151983150983140983141983150983155983137983156983141 R983141983149983151983158983137983148 P983157983149983152Can be ield-installed Assists in removing condensatedeveloped by heat pump operation and transers it to

indoor coil to dissipate into room while adding humidityto the room

F983137983139983156983151983154983161 I983150983155983156983137983148983148983141983140 Feature Code - P

PVK3A 230208V ndash R-22

PVK4A 265V ndash R-22

D983157983139983156 E983160983156983141983150983155983145983151983150 K983145983156Extends air distribution to an adjoining room Consistsof a main duct for the room of origin and an extensionduct to reach the adjoining room and terminal ductPTDK01A allows for the ldquoBrdquo series unit to work with theldquoArdquo series duct kits

MDK02B Main Duct ndash R-22

MDK01E Main Duct ndash R-410A

EDK02B 42 Extension Duct

TRANSITION BAFFLES

Main Duct Kit

TDK02B Terminal Duct

PTDK01A Transition Duct Only ndash R-22

PTDK01E Transition Duct Only ndash R-410A

Extension Duct Kit

Terminal Duct Kit

DGK1B Condenser Baffle Kit

SBEC10A 10 Pack

Basepan

Condenser

Condenser Baffles

KL03B Security Key Lock (R-22)

KL03E Security Key Lock (R-410A)

CDP302 230208V ndash R-22

CDP402 265V ndash R-22

CDP303E 230208V ndash R-410A

8182019 mc-dptac

httpslidepdfcomreaderfullmc-dptac 1420

14 wwwamana-ptaccom

Accessories (cont)

HWK03B Hydronic Water Kit ndash R-22

HVK03B Hydronic Steam Kit ndash R-22

HWK03E Hydronic Water Kit ndash R-410A

HVK03E Hydronic Steam Kit ndash R-410A

ThermostatsThe ollowing thermostats offer remote control Any thermostat other than those listed must be submitted to Goodman Company LPor approval prior to use

H983161983140983154983151983150983145983139 H983141983137983156 K983145983156Add-on kits it all units allowing the addition o hydronicwater or hydronic steam heat to cooling and heating unitsThe kits eature lef- or right-hand piping Unit retainscomplete service access with a kit installed Unit must beconnected to and operated by a wall thermostat

Hydronic Heat Kit Top View

Hydronic Heat Kit Right View

M983151983140983141983148 H983141983137983156 S983156983137983143983141983155 C983151983151983148 S983156983137983143983141983155 F983137983150 S983152983141983141983140 983151983142 W983145983154983141983155R983141983153983157983145983154983141983140

T983141983149983152L983145983149983145983156983145983150983143

B983137983139983147983148983145983156 D983145983155983152983148983137983161 T983161983152983141S983144983137983152983141 983078

O983154983145983141983150983156983137983156983145983151983150C983151983150983150983141983139983156983145983151983150

2246002 1 1 1 5 No Yes Digital Manual RectHoriz Wired

2246003 2 2 2 7 Yes Yes Digital Manual RectHoriz Wired

2246007 2 2 1 7 Yes Yes Digital Auto-Change RectHoriz Wired

2246008 2 2 1 7 Yes Yes Digital Programmable RectHoriz Wired

DS01E 2 2 2 0 Yes Yes Digital Manual RectHoriz Wireless

Battery powered but has optional hard wire capability Requires DT01G Antennae or operation

Hydronic Heat KitSide View

8182019 mc-dptac

httpslidepdfcomreaderfullmc-dptac 1520

15Specifications and Accessories Catalog

Accessories (cont)P983151983159983141983154 D983151983151983154 K983145983156Vent door will automatically open when unit an is on

Factory Installed Feature Code - D

H983161983140983154983151983150983145983139 V983137983148983158983141983155Water and steam valves are available or use with theHWK03 (water) and HVK03 (steam) heat kits

W983145983154983141983148983141983155983155 RF (R983137983140983145983151 F983154983141983153983157983141983150983139983161) C983151983150983156983154983151983148983155All DigiSmart PTACs come actory-ready to be con-trolledvia wireless RF devices 24 Ghz 802 154 protocol assuresrobust communications and response

W983137983148983148 S983148983141983141983158983141 E983160983156983141983150983155983145983151983150 A983140983137983152983156983141983154 K983145983156983155Room-side extension kits to increase the depth o theexisting sleeve to allow or an industry-standard PTAC tobe installed

C983157983154983156983137983145983150 B983137983142983142983148983141 K983145983156The color matched polymer curtain baffles help toprevent curtains rom alling into the discharge airstream and causing recirculation reducing efficienciesand shortening compressor lie

PDK3A 230208V ndash R-22

PDK4A 265V ndash R-22

PDK3E 230208V ndash R-410A

PDK4E 265V ndash R-410A

VS2WNCA 2-way24VNCSteam VS2WNOA 2-way24VNOSteam VW2WNCA 2-way24VNCEnd Switch

VW2WNOA 2-way24VNOEnd Switch VW3WNC2B 3-way24VNCNOEnd Switch

Poptop Actuator

DS01EThermostat 2-way2 Communications

DD01EOccupancy SensorEMS Activation2

DT01GAntenna RouterFactory InstalledFeature Code - R

GT01GGeneric RadioAntenna Router3

DD01F Door Switch EMS Activation2

DP01G Web-enabled Platorm Server

DL01GWeb-enabled PlatormServer Link BAC-NET capable

DR01G Mesh Repeater1

DL01G-SERIAL

Serial Repeater1

1 Consult Amana Sales representative priorto purchase

2 Requires DT01G or use3 Requires DS01E or use

SECM1001A 15 Extension or 12frac12 Climate Master Sleeve (10 Pack)

SEZA0501A 25 Extension or 11frac12 Zone Air Sleeve (5 pack)

PTCB10B 10 Pack or R-22 units

PTCB10E 10 Pack or R-410A units

8182019 mc-dptac

httpslidepdfcomreaderfullmc-dptac 1620

16 wwwamana-ptaccom

Unit with Accessory Wall Sleeve and Sub-base Accessory

3

11

6- 18 9- 91624 -5 16

40

42

Location of external drain holes on bottom flange of Wall Sleeve

3 Clearance

to side walls

Air Flow

Air Flow

Air Flow

Air Discharge Grille ControlDoor

T983151983152 V983145983141983159

F983154983151983150983156 V98314598314198315958 LCDI CORD SET mdash 230V208V UNIT

58 CORD SET 230V208V UNIT

18 CORD SET 2 65V UNIT

3-14

MIN

2

MAX

2-58

42

16-116

RI GHTLEFT

1 and frac34 Concentric knock-outs back ampbottom o sub-base (electrical only)

R983145983143983144983156 V983145983141983159

2frac34

4

11⅜

983225983219 frasl ₁₆

983225983219 frasl ₁₆ 1⅜

16983225 frasl ₁₆

1⅜Arch Grille

⅞Stamped Grille

14⅛Wall Sleeve

21frac12

7⅜

Optional

Sub-base

HingedControlDoor

15deg

40deg

Air discharge grille is reversible to provideeither 15deg or 40deg discharge angle

frac12 ODCopperDrain Tube

8182019 mc-dptac

httpslidepdfcomreaderfullmc-dptac 1720

17Specifications and Accessories Catalog

Framing or Accessory Wall Sleeve (WS9XX)F983137983155983156983141983150983145983150983143 W983137983148983148 S983148983141983141983158983141When installed in an opening the Wall Sleeve must behorizontally level (side-to-side) and pitched frac14 bubble to the outside

(NOTE To ensure unitrsquos maximum efficiency DO NOT over- or under-pitch)

I983150983155983156983137983148983148983137983156983145983151983150 N9831519831569831419831551 I Sub-base (PTSBE) is installed allow minimum

3frac14 height clearance and maximum 5 heightclearance between wall sleeve and loor allowminimum 2frac34 protrusion rom a inished wallSee Note 4 if using hydronic units

2 Drain Kit (DK900D) shipped separately Can bemounted either right side lef side or bottom osleeve I mounted to bottom o sleeve allow2 height clearance rom loor to bottom o sleeve

3 For UL approval 265V units must use Amanareg brandSub-base (PTSBE) or Amanareg brand Hard WireKit (PSHW04A) Overcurrent protection on 265V unitsmust be by cartridge-style time delay uses whichare included and factory-installed on the Amanareg brand 265V chassis

4 I Hydronic Kit (HWK03 or HVK03) is installedWall Sleeve must extend exactly 3 into the roomrom the inished interior wall I using the Amana reg brand Sub-base (PTSBE) only the minimum3frac14 height clearance between wall sleeve and loor

is permissible Unit must also be operated with aremote-mounted thermostat

5 I Duct Kit (MDK) is installed allow a minimum o2⅜ into the room rom the inished interior wall

MountingHoles(Drilled byInstaller)

PlasticAnchor

Screws

ExpansionAnchor Bolt

Toggle Bolt

Wood Screw

AlternativeFastening Method(Field Supplied)

Wall Sleeve must extend a minimum o frac14 beyond outside wall to allow orproper caulking

FINISHED FLOOR

4 2 1 4

16 14

MIN

MAIN STUD

JACK STUDS

HEADER - 4 x 4 OR

DOUBLE 2x 4 ON EDGE

SUB-FLOOR

CRIPPLE

JACK STUD

ADJUST FRAMING TO

SECURE THIS DIMENSION

Wall sleeve opening height should be squared withwall sleeve opening width

H = 16frac14

W = 42frac14

8182019 mc-dptac

httpslidepdfcomreaderfullmc-dptac 1820

Notes

8182019 mc-dptac

httpslidepdfcomreaderfullmc-dptac 1920

Our continuing commitment to quality products may mean a change in speciications without noticecopy 2015 Goodman Company LP Amana is a registered trademark o Maytag Corporation or its related

companies and is used under license to Goodman Company LP Houston TX USA All rights reserved

Quiet two-an motor system

Energy-eicient perormance

DigiSmartreg wireless controls on select models

Wise DecisionItrsquos an Amanareg brand

8182019 mc-dptac

httpslidepdfcomreaderfullmc-dptac 2020

Our continuing commitment to quality products may mean a change in speciications without notice copy 2015 Goodman Company LPAmana is a registered trademark o Maytag Corporation or its related companies and is used under license to Goodman Company L P

wwwamana-ptaccom

Call your Amana brand PTAC sales representative at 800-647-2982 or complete details

Beore purchasing this appliance read important inormation about its estimated annual energy

consumption yearly operating cost or energy efficiency rating that is available rom your retailer

A legacy o comortThe impeccable reputation oan American original

Amana heating and cooling systems are a part of the

enduring legacy of one of Americarsquos most recognized

and respected brands Originating eight decades ago in

Amana Iowa the brand is synonymous with long-last-

ing premium-quality products mdash from home appliances

to heating and air conditioning equipment Chances

are you and generations beore you have enjoyed the

dependable performance and longevity the Amana

brand continues to deliver

MC-DPTAC 07-15Supersedes 06-15

Page 13: mc-dptac

8182019 mc-dptac

httpslidepdfcomreaderfullmc-dptac 1320

13Specifications and Accessories Catalog

Accessories (cont)

P983151983159983141983154 V983141983150983156 K983145983156Installation o Power Vent increases CFM up toapproximately 95 Vent door will automatically closewhen unit an is off

F983137983139983156983151983154983161 I983150983155983156983137983148983148983141983140 Feature Code - VR-410A models must have these kits installed atthe actory

C983151983150983140983141983150983155983141983154 B983137983142983142983148983141 K983145983156For use on non-baffled grilles These delectors directthe air in toward the center and away rom the inlet toprevent recirculation o the hot condenser air

S983157983138983085983138983137983155983141 E983160983156983141983150983155983145983151983150 C983151983158983141983154 K983145983156Converts older 30-amp sub-bases to allow or installationo the larger 30-amp LCDI power cord and plugs

S983141983139983157983154983145983156983161 K983141983161 L983151983139983147983155In conjunction with the tamper-resistant ront theinstallation o Amanareg brand security key locks preventstampering o the controls used to set temperature heatingand cooling unctions UL approved or institutionaluse only

C983151983150983140983141983150983155983137983156983141 R983141983149983151983158983137983148 P983157983149983152Can be ield-installed Assists in removing condensatedeveloped by heat pump operation and transers it to

indoor coil to dissipate into room while adding humidityto the room

F983137983139983156983151983154983161 I983150983155983156983137983148983148983141983140 Feature Code - P

PVK3A 230208V ndash R-22

PVK4A 265V ndash R-22

D983157983139983156 E983160983156983141983150983155983145983151983150 K983145983156Extends air distribution to an adjoining room Consistsof a main duct for the room of origin and an extensionduct to reach the adjoining room and terminal ductPTDK01A allows for the ldquoBrdquo series unit to work with theldquoArdquo series duct kits

MDK02B Main Duct ndash R-22

MDK01E Main Duct ndash R-410A

EDK02B 42 Extension Duct

TRANSITION BAFFLES

Main Duct Kit

TDK02B Terminal Duct

PTDK01A Transition Duct Only ndash R-22

PTDK01E Transition Duct Only ndash R-410A

Extension Duct Kit

Terminal Duct Kit

DGK1B Condenser Baffle Kit

SBEC10A 10 Pack

Basepan

Condenser

Condenser Baffles

KL03B Security Key Lock (R-22)

KL03E Security Key Lock (R-410A)

CDP302 230208V ndash R-22

CDP402 265V ndash R-22

CDP303E 230208V ndash R-410A

8182019 mc-dptac

httpslidepdfcomreaderfullmc-dptac 1420

14 wwwamana-ptaccom

Accessories (cont)

HWK03B Hydronic Water Kit ndash R-22

HVK03B Hydronic Steam Kit ndash R-22

HWK03E Hydronic Water Kit ndash R-410A

HVK03E Hydronic Steam Kit ndash R-410A

ThermostatsThe ollowing thermostats offer remote control Any thermostat other than those listed must be submitted to Goodman Company LPor approval prior to use

H983161983140983154983151983150983145983139 H983141983137983156 K983145983156Add-on kits it all units allowing the addition o hydronicwater or hydronic steam heat to cooling and heating unitsThe kits eature lef- or right-hand piping Unit retainscomplete service access with a kit installed Unit must beconnected to and operated by a wall thermostat

Hydronic Heat Kit Top View

Hydronic Heat Kit Right View

M983151983140983141983148 H983141983137983156 S983156983137983143983141983155 C983151983151983148 S983156983137983143983141983155 F983137983150 S983152983141983141983140 983151983142 W983145983154983141983155R983141983153983157983145983154983141983140

T983141983149983152L983145983149983145983156983145983150983143

B983137983139983147983148983145983156 D983145983155983152983148983137983161 T983161983152983141S983144983137983152983141 983078

O983154983145983141983150983156983137983156983145983151983150C983151983150983150983141983139983156983145983151983150

2246002 1 1 1 5 No Yes Digital Manual RectHoriz Wired

2246003 2 2 2 7 Yes Yes Digital Manual RectHoriz Wired

2246007 2 2 1 7 Yes Yes Digital Auto-Change RectHoriz Wired

2246008 2 2 1 7 Yes Yes Digital Programmable RectHoriz Wired

DS01E 2 2 2 0 Yes Yes Digital Manual RectHoriz Wireless

Battery powered but has optional hard wire capability Requires DT01G Antennae or operation

Hydronic Heat KitSide View

8182019 mc-dptac

httpslidepdfcomreaderfullmc-dptac 1520

15Specifications and Accessories Catalog

Accessories (cont)P983151983159983141983154 D983151983151983154 K983145983156Vent door will automatically open when unit an is on

Factory Installed Feature Code - D

H983161983140983154983151983150983145983139 V983137983148983158983141983155Water and steam valves are available or use with theHWK03 (water) and HVK03 (steam) heat kits

W983145983154983141983148983141983155983155 RF (R983137983140983145983151 F983154983141983153983157983141983150983139983161) C983151983150983156983154983151983148983155All DigiSmart PTACs come actory-ready to be con-trolledvia wireless RF devices 24 Ghz 802 154 protocol assuresrobust communications and response

W983137983148983148 S983148983141983141983158983141 E983160983156983141983150983155983145983151983150 A983140983137983152983156983141983154 K983145983156983155Room-side extension kits to increase the depth o theexisting sleeve to allow or an industry-standard PTAC tobe installed

C983157983154983156983137983145983150 B983137983142983142983148983141 K983145983156The color matched polymer curtain baffles help toprevent curtains rom alling into the discharge airstream and causing recirculation reducing efficienciesand shortening compressor lie

PDK3A 230208V ndash R-22

PDK4A 265V ndash R-22

PDK3E 230208V ndash R-410A

PDK4E 265V ndash R-410A

VS2WNCA 2-way24VNCSteam VS2WNOA 2-way24VNOSteam VW2WNCA 2-way24VNCEnd Switch

VW2WNOA 2-way24VNOEnd Switch VW3WNC2B 3-way24VNCNOEnd Switch

Poptop Actuator

DS01EThermostat 2-way2 Communications

DD01EOccupancy SensorEMS Activation2

DT01GAntenna RouterFactory InstalledFeature Code - R

GT01GGeneric RadioAntenna Router3

DD01F Door Switch EMS Activation2

DP01G Web-enabled Platorm Server

DL01GWeb-enabled PlatormServer Link BAC-NET capable

DR01G Mesh Repeater1

DL01G-SERIAL

Serial Repeater1

1 Consult Amana Sales representative priorto purchase

2 Requires DT01G or use3 Requires DS01E or use

SECM1001A 15 Extension or 12frac12 Climate Master Sleeve (10 Pack)

SEZA0501A 25 Extension or 11frac12 Zone Air Sleeve (5 pack)

PTCB10B 10 Pack or R-22 units

PTCB10E 10 Pack or R-410A units

8182019 mc-dptac

httpslidepdfcomreaderfullmc-dptac 1620

16 wwwamana-ptaccom

Unit with Accessory Wall Sleeve and Sub-base Accessory

3

11

6- 18 9- 91624 -5 16

40

42

Location of external drain holes on bottom flange of Wall Sleeve

3 Clearance

to side walls

Air Flow

Air Flow

Air Flow

Air Discharge Grille ControlDoor

T983151983152 V983145983141983159

F983154983151983150983156 V98314598314198315958 LCDI CORD SET mdash 230V208V UNIT

58 CORD SET 230V208V UNIT

18 CORD SET 2 65V UNIT

3-14

MIN

2

MAX

2-58

42

16-116

RI GHTLEFT

1 and frac34 Concentric knock-outs back ampbottom o sub-base (electrical only)

R983145983143983144983156 V983145983141983159

2frac34

4

11⅜

983225983219 frasl ₁₆

983225983219 frasl ₁₆ 1⅜

16983225 frasl ₁₆

1⅜Arch Grille

⅞Stamped Grille

14⅛Wall Sleeve

21frac12

7⅜

Optional

Sub-base

HingedControlDoor

15deg

40deg

Air discharge grille is reversible to provideeither 15deg or 40deg discharge angle

frac12 ODCopperDrain Tube

8182019 mc-dptac

httpslidepdfcomreaderfullmc-dptac 1720

17Specifications and Accessories Catalog

Framing or Accessory Wall Sleeve (WS9XX)F983137983155983156983141983150983145983150983143 W983137983148983148 S983148983141983141983158983141When installed in an opening the Wall Sleeve must behorizontally level (side-to-side) and pitched frac14 bubble to the outside

(NOTE To ensure unitrsquos maximum efficiency DO NOT over- or under-pitch)

I983150983155983156983137983148983148983137983156983145983151983150 N9831519831569831419831551 I Sub-base (PTSBE) is installed allow minimum

3frac14 height clearance and maximum 5 heightclearance between wall sleeve and loor allowminimum 2frac34 protrusion rom a inished wallSee Note 4 if using hydronic units

2 Drain Kit (DK900D) shipped separately Can bemounted either right side lef side or bottom osleeve I mounted to bottom o sleeve allow2 height clearance rom loor to bottom o sleeve

3 For UL approval 265V units must use Amanareg brandSub-base (PTSBE) or Amanareg brand Hard WireKit (PSHW04A) Overcurrent protection on 265V unitsmust be by cartridge-style time delay uses whichare included and factory-installed on the Amanareg brand 265V chassis

4 I Hydronic Kit (HWK03 or HVK03) is installedWall Sleeve must extend exactly 3 into the roomrom the inished interior wall I using the Amana reg brand Sub-base (PTSBE) only the minimum3frac14 height clearance between wall sleeve and loor

is permissible Unit must also be operated with aremote-mounted thermostat

5 I Duct Kit (MDK) is installed allow a minimum o2⅜ into the room rom the inished interior wall

MountingHoles(Drilled byInstaller)

PlasticAnchor

Screws

ExpansionAnchor Bolt

Toggle Bolt

Wood Screw

AlternativeFastening Method(Field Supplied)

Wall Sleeve must extend a minimum o frac14 beyond outside wall to allow orproper caulking

FINISHED FLOOR

4 2 1 4

16 14

MIN

MAIN STUD

JACK STUDS

HEADER - 4 x 4 OR

DOUBLE 2x 4 ON EDGE

SUB-FLOOR

CRIPPLE

JACK STUD

ADJUST FRAMING TO

SECURE THIS DIMENSION

Wall sleeve opening height should be squared withwall sleeve opening width

H = 16frac14

W = 42frac14

8182019 mc-dptac

httpslidepdfcomreaderfullmc-dptac 1820

Notes

8182019 mc-dptac

httpslidepdfcomreaderfullmc-dptac 1920

Our continuing commitment to quality products may mean a change in speciications without noticecopy 2015 Goodman Company LP Amana is a registered trademark o Maytag Corporation or its related

companies and is used under license to Goodman Company LP Houston TX USA All rights reserved

Quiet two-an motor system

Energy-eicient perormance

DigiSmartreg wireless controls on select models

Wise DecisionItrsquos an Amanareg brand

8182019 mc-dptac

httpslidepdfcomreaderfullmc-dptac 2020

Our continuing commitment to quality products may mean a change in speciications without notice copy 2015 Goodman Company LPAmana is a registered trademark o Maytag Corporation or its related companies and is used under license to Goodman Company L P

wwwamana-ptaccom

Call your Amana brand PTAC sales representative at 800-647-2982 or complete details

Beore purchasing this appliance read important inormation about its estimated annual energy

consumption yearly operating cost or energy efficiency rating that is available rom your retailer

A legacy o comortThe impeccable reputation oan American original

Amana heating and cooling systems are a part of the

enduring legacy of one of Americarsquos most recognized

and respected brands Originating eight decades ago in

Amana Iowa the brand is synonymous with long-last-

ing premium-quality products mdash from home appliances

to heating and air conditioning equipment Chances

are you and generations beore you have enjoyed the

dependable performance and longevity the Amana

brand continues to deliver

MC-DPTAC 07-15Supersedes 06-15

Page 14: mc-dptac

8182019 mc-dptac

httpslidepdfcomreaderfullmc-dptac 1420

14 wwwamana-ptaccom

Accessories (cont)

HWK03B Hydronic Water Kit ndash R-22

HVK03B Hydronic Steam Kit ndash R-22

HWK03E Hydronic Water Kit ndash R-410A

HVK03E Hydronic Steam Kit ndash R-410A

ThermostatsThe ollowing thermostats offer remote control Any thermostat other than those listed must be submitted to Goodman Company LPor approval prior to use

H983161983140983154983151983150983145983139 H983141983137983156 K983145983156Add-on kits it all units allowing the addition o hydronicwater or hydronic steam heat to cooling and heating unitsThe kits eature lef- or right-hand piping Unit retainscomplete service access with a kit installed Unit must beconnected to and operated by a wall thermostat

Hydronic Heat Kit Top View

Hydronic Heat Kit Right View

M983151983140983141983148 H983141983137983156 S983156983137983143983141983155 C983151983151983148 S983156983137983143983141983155 F983137983150 S983152983141983141983140 983151983142 W983145983154983141983155R983141983153983157983145983154983141983140

T983141983149983152L983145983149983145983156983145983150983143

B983137983139983147983148983145983156 D983145983155983152983148983137983161 T983161983152983141S983144983137983152983141 983078

O983154983145983141983150983156983137983156983145983151983150C983151983150983150983141983139983156983145983151983150

2246002 1 1 1 5 No Yes Digital Manual RectHoriz Wired

2246003 2 2 2 7 Yes Yes Digital Manual RectHoriz Wired

2246007 2 2 1 7 Yes Yes Digital Auto-Change RectHoriz Wired

2246008 2 2 1 7 Yes Yes Digital Programmable RectHoriz Wired

DS01E 2 2 2 0 Yes Yes Digital Manual RectHoriz Wireless

Battery powered but has optional hard wire capability Requires DT01G Antennae or operation

Hydronic Heat KitSide View

8182019 mc-dptac

httpslidepdfcomreaderfullmc-dptac 1520

15Specifications and Accessories Catalog

Accessories (cont)P983151983159983141983154 D983151983151983154 K983145983156Vent door will automatically open when unit an is on

Factory Installed Feature Code - D

H983161983140983154983151983150983145983139 V983137983148983158983141983155Water and steam valves are available or use with theHWK03 (water) and HVK03 (steam) heat kits

W983145983154983141983148983141983155983155 RF (R983137983140983145983151 F983154983141983153983157983141983150983139983161) C983151983150983156983154983151983148983155All DigiSmart PTACs come actory-ready to be con-trolledvia wireless RF devices 24 Ghz 802 154 protocol assuresrobust communications and response

W983137983148983148 S983148983141983141983158983141 E983160983156983141983150983155983145983151983150 A983140983137983152983156983141983154 K983145983156983155Room-side extension kits to increase the depth o theexisting sleeve to allow or an industry-standard PTAC tobe installed

C983157983154983156983137983145983150 B983137983142983142983148983141 K983145983156The color matched polymer curtain baffles help toprevent curtains rom alling into the discharge airstream and causing recirculation reducing efficienciesand shortening compressor lie

PDK3A 230208V ndash R-22

PDK4A 265V ndash R-22

PDK3E 230208V ndash R-410A

PDK4E 265V ndash R-410A

VS2WNCA 2-way24VNCSteam VS2WNOA 2-way24VNOSteam VW2WNCA 2-way24VNCEnd Switch

VW2WNOA 2-way24VNOEnd Switch VW3WNC2B 3-way24VNCNOEnd Switch

Poptop Actuator

DS01EThermostat 2-way2 Communications

DD01EOccupancy SensorEMS Activation2

DT01GAntenna RouterFactory InstalledFeature Code - R

GT01GGeneric RadioAntenna Router3

DD01F Door Switch EMS Activation2

DP01G Web-enabled Platorm Server

DL01GWeb-enabled PlatormServer Link BAC-NET capable

DR01G Mesh Repeater1

DL01G-SERIAL

Serial Repeater1

1 Consult Amana Sales representative priorto purchase

2 Requires DT01G or use3 Requires DS01E or use

SECM1001A 15 Extension or 12frac12 Climate Master Sleeve (10 Pack)

SEZA0501A 25 Extension or 11frac12 Zone Air Sleeve (5 pack)

PTCB10B 10 Pack or R-22 units

PTCB10E 10 Pack or R-410A units

8182019 mc-dptac

httpslidepdfcomreaderfullmc-dptac 1620

16 wwwamana-ptaccom

Unit with Accessory Wall Sleeve and Sub-base Accessory

3

11

6- 18 9- 91624 -5 16

40

42

Location of external drain holes on bottom flange of Wall Sleeve

3 Clearance

to side walls

Air Flow

Air Flow

Air Flow

Air Discharge Grille ControlDoor

T983151983152 V983145983141983159

F983154983151983150983156 V98314598314198315958 LCDI CORD SET mdash 230V208V UNIT

58 CORD SET 230V208V UNIT

18 CORD SET 2 65V UNIT

3-14

MIN

2

MAX

2-58

42

16-116

RI GHTLEFT

1 and frac34 Concentric knock-outs back ampbottom o sub-base (electrical only)

R983145983143983144983156 V983145983141983159

2frac34

4

11⅜

983225983219 frasl ₁₆

983225983219 frasl ₁₆ 1⅜

16983225 frasl ₁₆

1⅜Arch Grille

⅞Stamped Grille

14⅛Wall Sleeve

21frac12

7⅜

Optional

Sub-base

HingedControlDoor

15deg

40deg

Air discharge grille is reversible to provideeither 15deg or 40deg discharge angle

frac12 ODCopperDrain Tube

8182019 mc-dptac

httpslidepdfcomreaderfullmc-dptac 1720

17Specifications and Accessories Catalog

Framing or Accessory Wall Sleeve (WS9XX)F983137983155983156983141983150983145983150983143 W983137983148983148 S983148983141983141983158983141When installed in an opening the Wall Sleeve must behorizontally level (side-to-side) and pitched frac14 bubble to the outside

(NOTE To ensure unitrsquos maximum efficiency DO NOT over- or under-pitch)

I983150983155983156983137983148983148983137983156983145983151983150 N9831519831569831419831551 I Sub-base (PTSBE) is installed allow minimum

3frac14 height clearance and maximum 5 heightclearance between wall sleeve and loor allowminimum 2frac34 protrusion rom a inished wallSee Note 4 if using hydronic units

2 Drain Kit (DK900D) shipped separately Can bemounted either right side lef side or bottom osleeve I mounted to bottom o sleeve allow2 height clearance rom loor to bottom o sleeve

3 For UL approval 265V units must use Amanareg brandSub-base (PTSBE) or Amanareg brand Hard WireKit (PSHW04A) Overcurrent protection on 265V unitsmust be by cartridge-style time delay uses whichare included and factory-installed on the Amanareg brand 265V chassis

4 I Hydronic Kit (HWK03 or HVK03) is installedWall Sleeve must extend exactly 3 into the roomrom the inished interior wall I using the Amana reg brand Sub-base (PTSBE) only the minimum3frac14 height clearance between wall sleeve and loor

is permissible Unit must also be operated with aremote-mounted thermostat

5 I Duct Kit (MDK) is installed allow a minimum o2⅜ into the room rom the inished interior wall

MountingHoles(Drilled byInstaller)

PlasticAnchor

Screws

ExpansionAnchor Bolt

Toggle Bolt

Wood Screw

AlternativeFastening Method(Field Supplied)

Wall Sleeve must extend a minimum o frac14 beyond outside wall to allow orproper caulking

FINISHED FLOOR

4 2 1 4

16 14

MIN

MAIN STUD

JACK STUDS

HEADER - 4 x 4 OR

DOUBLE 2x 4 ON EDGE

SUB-FLOOR

CRIPPLE

JACK STUD

ADJUST FRAMING TO

SECURE THIS DIMENSION

Wall sleeve opening height should be squared withwall sleeve opening width

H = 16frac14

W = 42frac14

8182019 mc-dptac

httpslidepdfcomreaderfullmc-dptac 1820

Notes

8182019 mc-dptac

httpslidepdfcomreaderfullmc-dptac 1920

Our continuing commitment to quality products may mean a change in speciications without noticecopy 2015 Goodman Company LP Amana is a registered trademark o Maytag Corporation or its related

companies and is used under license to Goodman Company LP Houston TX USA All rights reserved

Quiet two-an motor system

Energy-eicient perormance

DigiSmartreg wireless controls on select models

Wise DecisionItrsquos an Amanareg brand

8182019 mc-dptac

httpslidepdfcomreaderfullmc-dptac 2020

Our continuing commitment to quality products may mean a change in speciications without notice copy 2015 Goodman Company LPAmana is a registered trademark o Maytag Corporation or its related companies and is used under license to Goodman Company L P

wwwamana-ptaccom

Call your Amana brand PTAC sales representative at 800-647-2982 or complete details

Beore purchasing this appliance read important inormation about its estimated annual energy

consumption yearly operating cost or energy efficiency rating that is available rom your retailer

A legacy o comortThe impeccable reputation oan American original

Amana heating and cooling systems are a part of the

enduring legacy of one of Americarsquos most recognized

and respected brands Originating eight decades ago in

Amana Iowa the brand is synonymous with long-last-

ing premium-quality products mdash from home appliances

to heating and air conditioning equipment Chances

are you and generations beore you have enjoyed the

dependable performance and longevity the Amana

brand continues to deliver

MC-DPTAC 07-15Supersedes 06-15

Page 15: mc-dptac

8182019 mc-dptac

httpslidepdfcomreaderfullmc-dptac 1520

15Specifications and Accessories Catalog

Accessories (cont)P983151983159983141983154 D983151983151983154 K983145983156Vent door will automatically open when unit an is on

Factory Installed Feature Code - D

H983161983140983154983151983150983145983139 V983137983148983158983141983155Water and steam valves are available or use with theHWK03 (water) and HVK03 (steam) heat kits

W983145983154983141983148983141983155983155 RF (R983137983140983145983151 F983154983141983153983157983141983150983139983161) C983151983150983156983154983151983148983155All DigiSmart PTACs come actory-ready to be con-trolledvia wireless RF devices 24 Ghz 802 154 protocol assuresrobust communications and response

W983137983148983148 S983148983141983141983158983141 E983160983156983141983150983155983145983151983150 A983140983137983152983156983141983154 K983145983156983155Room-side extension kits to increase the depth o theexisting sleeve to allow or an industry-standard PTAC tobe installed

C983157983154983156983137983145983150 B983137983142983142983148983141 K983145983156The color matched polymer curtain baffles help toprevent curtains rom alling into the discharge airstream and causing recirculation reducing efficienciesand shortening compressor lie

PDK3A 230208V ndash R-22

PDK4A 265V ndash R-22

PDK3E 230208V ndash R-410A

PDK4E 265V ndash R-410A

VS2WNCA 2-way24VNCSteam VS2WNOA 2-way24VNOSteam VW2WNCA 2-way24VNCEnd Switch

VW2WNOA 2-way24VNOEnd Switch VW3WNC2B 3-way24VNCNOEnd Switch

Poptop Actuator

DS01EThermostat 2-way2 Communications

DD01EOccupancy SensorEMS Activation2

DT01GAntenna RouterFactory InstalledFeature Code - R

GT01GGeneric RadioAntenna Router3

DD01F Door Switch EMS Activation2

DP01G Web-enabled Platorm Server

DL01GWeb-enabled PlatormServer Link BAC-NET capable

DR01G Mesh Repeater1

DL01G-SERIAL

Serial Repeater1

1 Consult Amana Sales representative priorto purchase

2 Requires DT01G or use3 Requires DS01E or use

SECM1001A 15 Extension or 12frac12 Climate Master Sleeve (10 Pack)

SEZA0501A 25 Extension or 11frac12 Zone Air Sleeve (5 pack)

PTCB10B 10 Pack or R-22 units

PTCB10E 10 Pack or R-410A units

8182019 mc-dptac

httpslidepdfcomreaderfullmc-dptac 1620

16 wwwamana-ptaccom

Unit with Accessory Wall Sleeve and Sub-base Accessory

3

11

6- 18 9- 91624 -5 16

40

42

Location of external drain holes on bottom flange of Wall Sleeve

3 Clearance

to side walls

Air Flow

Air Flow

Air Flow

Air Discharge Grille ControlDoor

T983151983152 V983145983141983159

F983154983151983150983156 V98314598314198315958 LCDI CORD SET mdash 230V208V UNIT

58 CORD SET 230V208V UNIT

18 CORD SET 2 65V UNIT

3-14

MIN

2

MAX

2-58

42

16-116

RI GHTLEFT

1 and frac34 Concentric knock-outs back ampbottom o sub-base (electrical only)

R983145983143983144983156 V983145983141983159

2frac34

4

11⅜

983225983219 frasl ₁₆

983225983219 frasl ₁₆ 1⅜

16983225 frasl ₁₆

1⅜Arch Grille

⅞Stamped Grille

14⅛Wall Sleeve

21frac12

7⅜

Optional

Sub-base

HingedControlDoor

15deg

40deg

Air discharge grille is reversible to provideeither 15deg or 40deg discharge angle

frac12 ODCopperDrain Tube

8182019 mc-dptac

httpslidepdfcomreaderfullmc-dptac 1720

17Specifications and Accessories Catalog

Framing or Accessory Wall Sleeve (WS9XX)F983137983155983156983141983150983145983150983143 W983137983148983148 S983148983141983141983158983141When installed in an opening the Wall Sleeve must behorizontally level (side-to-side) and pitched frac14 bubble to the outside

(NOTE To ensure unitrsquos maximum efficiency DO NOT over- or under-pitch)

I983150983155983156983137983148983148983137983156983145983151983150 N9831519831569831419831551 I Sub-base (PTSBE) is installed allow minimum

3frac14 height clearance and maximum 5 heightclearance between wall sleeve and loor allowminimum 2frac34 protrusion rom a inished wallSee Note 4 if using hydronic units

2 Drain Kit (DK900D) shipped separately Can bemounted either right side lef side or bottom osleeve I mounted to bottom o sleeve allow2 height clearance rom loor to bottom o sleeve

3 For UL approval 265V units must use Amanareg brandSub-base (PTSBE) or Amanareg brand Hard WireKit (PSHW04A) Overcurrent protection on 265V unitsmust be by cartridge-style time delay uses whichare included and factory-installed on the Amanareg brand 265V chassis

4 I Hydronic Kit (HWK03 or HVK03) is installedWall Sleeve must extend exactly 3 into the roomrom the inished interior wall I using the Amana reg brand Sub-base (PTSBE) only the minimum3frac14 height clearance between wall sleeve and loor

is permissible Unit must also be operated with aremote-mounted thermostat

5 I Duct Kit (MDK) is installed allow a minimum o2⅜ into the room rom the inished interior wall

MountingHoles(Drilled byInstaller)

PlasticAnchor

Screws

ExpansionAnchor Bolt

Toggle Bolt

Wood Screw

AlternativeFastening Method(Field Supplied)

Wall Sleeve must extend a minimum o frac14 beyond outside wall to allow orproper caulking

FINISHED FLOOR

4 2 1 4

16 14

MIN

MAIN STUD

JACK STUDS

HEADER - 4 x 4 OR

DOUBLE 2x 4 ON EDGE

SUB-FLOOR

CRIPPLE

JACK STUD

ADJUST FRAMING TO

SECURE THIS DIMENSION

Wall sleeve opening height should be squared withwall sleeve opening width

H = 16frac14

W = 42frac14

8182019 mc-dptac

httpslidepdfcomreaderfullmc-dptac 1820

Notes

8182019 mc-dptac

httpslidepdfcomreaderfullmc-dptac 1920

Our continuing commitment to quality products may mean a change in speciications without noticecopy 2015 Goodman Company LP Amana is a registered trademark o Maytag Corporation or its related

companies and is used under license to Goodman Company LP Houston TX USA All rights reserved

Quiet two-an motor system

Energy-eicient perormance

DigiSmartreg wireless controls on select models

Wise DecisionItrsquos an Amanareg brand

8182019 mc-dptac

httpslidepdfcomreaderfullmc-dptac 2020

Our continuing commitment to quality products may mean a change in speciications without notice copy 2015 Goodman Company LPAmana is a registered trademark o Maytag Corporation or its related companies and is used under license to Goodman Company L P

wwwamana-ptaccom

Call your Amana brand PTAC sales representative at 800-647-2982 or complete details

Beore purchasing this appliance read important inormation about its estimated annual energy

consumption yearly operating cost or energy efficiency rating that is available rom your retailer

A legacy o comortThe impeccable reputation oan American original

Amana heating and cooling systems are a part of the

enduring legacy of one of Americarsquos most recognized

and respected brands Originating eight decades ago in

Amana Iowa the brand is synonymous with long-last-

ing premium-quality products mdash from home appliances

to heating and air conditioning equipment Chances

are you and generations beore you have enjoyed the

dependable performance and longevity the Amana

brand continues to deliver

MC-DPTAC 07-15Supersedes 06-15

Page 16: mc-dptac

8182019 mc-dptac

httpslidepdfcomreaderfullmc-dptac 1620

16 wwwamana-ptaccom

Unit with Accessory Wall Sleeve and Sub-base Accessory

3

11

6- 18 9- 91624 -5 16

40

42

Location of external drain holes on bottom flange of Wall Sleeve

3 Clearance

to side walls

Air Flow

Air Flow

Air Flow

Air Discharge Grille ControlDoor

T983151983152 V983145983141983159

F983154983151983150983156 V98314598314198315958 LCDI CORD SET mdash 230V208V UNIT

58 CORD SET 230V208V UNIT

18 CORD SET 2 65V UNIT

3-14

MIN

2

MAX

2-58

42

16-116

RI GHTLEFT

1 and frac34 Concentric knock-outs back ampbottom o sub-base (electrical only)

R983145983143983144983156 V983145983141983159

2frac34

4

11⅜

983225983219 frasl ₁₆

983225983219 frasl ₁₆ 1⅜

16983225 frasl ₁₆

1⅜Arch Grille

⅞Stamped Grille

14⅛Wall Sleeve

21frac12

7⅜

Optional

Sub-base

HingedControlDoor

15deg

40deg

Air discharge grille is reversible to provideeither 15deg or 40deg discharge angle

frac12 ODCopperDrain Tube

8182019 mc-dptac

httpslidepdfcomreaderfullmc-dptac 1720

17Specifications and Accessories Catalog

Framing or Accessory Wall Sleeve (WS9XX)F983137983155983156983141983150983145983150983143 W983137983148983148 S983148983141983141983158983141When installed in an opening the Wall Sleeve must behorizontally level (side-to-side) and pitched frac14 bubble to the outside

(NOTE To ensure unitrsquos maximum efficiency DO NOT over- or under-pitch)

I983150983155983156983137983148983148983137983156983145983151983150 N9831519831569831419831551 I Sub-base (PTSBE) is installed allow minimum

3frac14 height clearance and maximum 5 heightclearance between wall sleeve and loor allowminimum 2frac34 protrusion rom a inished wallSee Note 4 if using hydronic units

2 Drain Kit (DK900D) shipped separately Can bemounted either right side lef side or bottom osleeve I mounted to bottom o sleeve allow2 height clearance rom loor to bottom o sleeve

3 For UL approval 265V units must use Amanareg brandSub-base (PTSBE) or Amanareg brand Hard WireKit (PSHW04A) Overcurrent protection on 265V unitsmust be by cartridge-style time delay uses whichare included and factory-installed on the Amanareg brand 265V chassis

4 I Hydronic Kit (HWK03 or HVK03) is installedWall Sleeve must extend exactly 3 into the roomrom the inished interior wall I using the Amana reg brand Sub-base (PTSBE) only the minimum3frac14 height clearance between wall sleeve and loor

is permissible Unit must also be operated with aremote-mounted thermostat

5 I Duct Kit (MDK) is installed allow a minimum o2⅜ into the room rom the inished interior wall

MountingHoles(Drilled byInstaller)

PlasticAnchor

Screws

ExpansionAnchor Bolt

Toggle Bolt

Wood Screw

AlternativeFastening Method(Field Supplied)

Wall Sleeve must extend a minimum o frac14 beyond outside wall to allow orproper caulking

FINISHED FLOOR

4 2 1 4

16 14

MIN

MAIN STUD

JACK STUDS

HEADER - 4 x 4 OR

DOUBLE 2x 4 ON EDGE

SUB-FLOOR

CRIPPLE

JACK STUD

ADJUST FRAMING TO

SECURE THIS DIMENSION

Wall sleeve opening height should be squared withwall sleeve opening width

H = 16frac14

W = 42frac14

8182019 mc-dptac

httpslidepdfcomreaderfullmc-dptac 1820

Notes

8182019 mc-dptac

httpslidepdfcomreaderfullmc-dptac 1920

Our continuing commitment to quality products may mean a change in speciications without noticecopy 2015 Goodman Company LP Amana is a registered trademark o Maytag Corporation or its related

companies and is used under license to Goodman Company LP Houston TX USA All rights reserved

Quiet two-an motor system

Energy-eicient perormance

DigiSmartreg wireless controls on select models

Wise DecisionItrsquos an Amanareg brand

8182019 mc-dptac

httpslidepdfcomreaderfullmc-dptac 2020

Our continuing commitment to quality products may mean a change in speciications without notice copy 2015 Goodman Company LPAmana is a registered trademark o Maytag Corporation or its related companies and is used under license to Goodman Company L P

wwwamana-ptaccom

Call your Amana brand PTAC sales representative at 800-647-2982 or complete details

Beore purchasing this appliance read important inormation about its estimated annual energy

consumption yearly operating cost or energy efficiency rating that is available rom your retailer

A legacy o comortThe impeccable reputation oan American original

Amana heating and cooling systems are a part of the

enduring legacy of one of Americarsquos most recognized

and respected brands Originating eight decades ago in

Amana Iowa the brand is synonymous with long-last-

ing premium-quality products mdash from home appliances

to heating and air conditioning equipment Chances

are you and generations beore you have enjoyed the

dependable performance and longevity the Amana

brand continues to deliver

MC-DPTAC 07-15Supersedes 06-15

Page 17: mc-dptac

8182019 mc-dptac

httpslidepdfcomreaderfullmc-dptac 1720

17Specifications and Accessories Catalog

Framing or Accessory Wall Sleeve (WS9XX)F983137983155983156983141983150983145983150983143 W983137983148983148 S983148983141983141983158983141When installed in an opening the Wall Sleeve must behorizontally level (side-to-side) and pitched frac14 bubble to the outside

(NOTE To ensure unitrsquos maximum efficiency DO NOT over- or under-pitch)

I983150983155983156983137983148983148983137983156983145983151983150 N9831519831569831419831551 I Sub-base (PTSBE) is installed allow minimum

3frac14 height clearance and maximum 5 heightclearance between wall sleeve and loor allowminimum 2frac34 protrusion rom a inished wallSee Note 4 if using hydronic units

2 Drain Kit (DK900D) shipped separately Can bemounted either right side lef side or bottom osleeve I mounted to bottom o sleeve allow2 height clearance rom loor to bottom o sleeve

3 For UL approval 265V units must use Amanareg brandSub-base (PTSBE) or Amanareg brand Hard WireKit (PSHW04A) Overcurrent protection on 265V unitsmust be by cartridge-style time delay uses whichare included and factory-installed on the Amanareg brand 265V chassis

4 I Hydronic Kit (HWK03 or HVK03) is installedWall Sleeve must extend exactly 3 into the roomrom the inished interior wall I using the Amana reg brand Sub-base (PTSBE) only the minimum3frac14 height clearance between wall sleeve and loor

is permissible Unit must also be operated with aremote-mounted thermostat

5 I Duct Kit (MDK) is installed allow a minimum o2⅜ into the room rom the inished interior wall

MountingHoles(Drilled byInstaller)

PlasticAnchor

Screws

ExpansionAnchor Bolt

Toggle Bolt

Wood Screw

AlternativeFastening Method(Field Supplied)

Wall Sleeve must extend a minimum o frac14 beyond outside wall to allow orproper caulking

FINISHED FLOOR

4 2 1 4

16 14

MIN

MAIN STUD

JACK STUDS

HEADER - 4 x 4 OR

DOUBLE 2x 4 ON EDGE

SUB-FLOOR

CRIPPLE

JACK STUD

ADJUST FRAMING TO

SECURE THIS DIMENSION

Wall sleeve opening height should be squared withwall sleeve opening width

H = 16frac14

W = 42frac14

8182019 mc-dptac

httpslidepdfcomreaderfullmc-dptac 1820

Notes

8182019 mc-dptac

httpslidepdfcomreaderfullmc-dptac 1920

Our continuing commitment to quality products may mean a change in speciications without noticecopy 2015 Goodman Company LP Amana is a registered trademark o Maytag Corporation or its related

companies and is used under license to Goodman Company LP Houston TX USA All rights reserved

Quiet two-an motor system

Energy-eicient perormance

DigiSmartreg wireless controls on select models

Wise DecisionItrsquos an Amanareg brand

8182019 mc-dptac

httpslidepdfcomreaderfullmc-dptac 2020

Our continuing commitment to quality products may mean a change in speciications without notice copy 2015 Goodman Company LPAmana is a registered trademark o Maytag Corporation or its related companies and is used under license to Goodman Company L P

wwwamana-ptaccom

Call your Amana brand PTAC sales representative at 800-647-2982 or complete details

Beore purchasing this appliance read important inormation about its estimated annual energy

consumption yearly operating cost or energy efficiency rating that is available rom your retailer

A legacy o comortThe impeccable reputation oan American original

Amana heating and cooling systems are a part of the

enduring legacy of one of Americarsquos most recognized

and respected brands Originating eight decades ago in

Amana Iowa the brand is synonymous with long-last-

ing premium-quality products mdash from home appliances

to heating and air conditioning equipment Chances

are you and generations beore you have enjoyed the

dependable performance and longevity the Amana

brand continues to deliver

MC-DPTAC 07-15Supersedes 06-15

Page 18: mc-dptac

8182019 mc-dptac

httpslidepdfcomreaderfullmc-dptac 1820

Notes

8182019 mc-dptac

httpslidepdfcomreaderfullmc-dptac 1920

Our continuing commitment to quality products may mean a change in speciications without noticecopy 2015 Goodman Company LP Amana is a registered trademark o Maytag Corporation or its related

companies and is used under license to Goodman Company LP Houston TX USA All rights reserved

Quiet two-an motor system

Energy-eicient perormance

DigiSmartreg wireless controls on select models

Wise DecisionItrsquos an Amanareg brand

8182019 mc-dptac

httpslidepdfcomreaderfullmc-dptac 2020

Our continuing commitment to quality products may mean a change in speciications without notice copy 2015 Goodman Company LPAmana is a registered trademark o Maytag Corporation or its related companies and is used under license to Goodman Company L P

wwwamana-ptaccom

Call your Amana brand PTAC sales representative at 800-647-2982 or complete details

Beore purchasing this appliance read important inormation about its estimated annual energy

consumption yearly operating cost or energy efficiency rating that is available rom your retailer

A legacy o comortThe impeccable reputation oan American original

Amana heating and cooling systems are a part of the

enduring legacy of one of Americarsquos most recognized

and respected brands Originating eight decades ago in

Amana Iowa the brand is synonymous with long-last-

ing premium-quality products mdash from home appliances

to heating and air conditioning equipment Chances

are you and generations beore you have enjoyed the

dependable performance and longevity the Amana

brand continues to deliver

MC-DPTAC 07-15Supersedes 06-15

Page 19: mc-dptac

8182019 mc-dptac

httpslidepdfcomreaderfullmc-dptac 1920

Our continuing commitment to quality products may mean a change in speciications without noticecopy 2015 Goodman Company LP Amana is a registered trademark o Maytag Corporation or its related

companies and is used under license to Goodman Company LP Houston TX USA All rights reserved

Quiet two-an motor system

Energy-eicient perormance

DigiSmartreg wireless controls on select models

Wise DecisionItrsquos an Amanareg brand

8182019 mc-dptac

httpslidepdfcomreaderfullmc-dptac 2020

Our continuing commitment to quality products may mean a change in speciications without notice copy 2015 Goodman Company LPAmana is a registered trademark o Maytag Corporation or its related companies and is used under license to Goodman Company L P

wwwamana-ptaccom

Call your Amana brand PTAC sales representative at 800-647-2982 or complete details

Beore purchasing this appliance read important inormation about its estimated annual energy

consumption yearly operating cost or energy efficiency rating that is available rom your retailer

A legacy o comortThe impeccable reputation oan American original

Amana heating and cooling systems are a part of the

enduring legacy of one of Americarsquos most recognized

and respected brands Originating eight decades ago in

Amana Iowa the brand is synonymous with long-last-

ing premium-quality products mdash from home appliances

to heating and air conditioning equipment Chances

are you and generations beore you have enjoyed the

dependable performance and longevity the Amana

brand continues to deliver

MC-DPTAC 07-15Supersedes 06-15

Page 20: mc-dptac

8182019 mc-dptac

httpslidepdfcomreaderfullmc-dptac 2020

Our continuing commitment to quality products may mean a change in speciications without notice copy 2015 Goodman Company LPAmana is a registered trademark o Maytag Corporation or its related companies and is used under license to Goodman Company L P

wwwamana-ptaccom

Call your Amana brand PTAC sales representative at 800-647-2982 or complete details

Beore purchasing this appliance read important inormation about its estimated annual energy

consumption yearly operating cost or energy efficiency rating that is available rom your retailer

A legacy o comortThe impeccable reputation oan American original

Amana heating and cooling systems are a part of the

enduring legacy of one of Americarsquos most recognized

and respected brands Originating eight decades ago in

Amana Iowa the brand is synonymous with long-last-

ing premium-quality products mdash from home appliances

to heating and air conditioning equipment Chances

are you and generations beore you have enjoyed the

dependable performance and longevity the Amana

brand continues to deliver

MC-DPTAC 07-15Supersedes 06-15