2
ERIDĒS LA GRAND'OURSE 16 rue Jean Sébastien BACH 42000 SAINT-ETIENNE 04 77 530 530 04 77 532 583 [email protected] www.erides.fr ERIDES reserves the right to make any necessary changes to the details contained in this notice. FT MCFC 10 Rev. B MCFC 10 Refrigeration cycle demonstration unit USE The equipment is composed of a transparent unit edged with anodised aluminium and elevated on feet. The transparent walls allow visibility on all sides whilst protecting both the equipment and its users. Once plugged in and connected to the water input and output, the machine works automatically. The visible condensation and evaporation allow for the understanding of the cycle processes. Once the machine has reached steady state, measurements can be taken and can be used even after the machine has been turned off. The fluid used is R134a which is universally accepted by the new European regulation. The regulation is controlled by a thermostatic expansion valve of equalized internal pressure. The unit allows for measurement of flow rate, pressure, temperature and more, depending on the option chosen. The fluid enthalpy chart is transposed onto a transparency at the centre of the unit allowing for rapid analysis of the fluid state parameters at any given point. EDUCATIONAL CAPABILITIES Study of the concept of vapour compression refrigeration Case of hermetic compressor / Fluide used: R134a / Sizing of components / Plot of theoretical refrigeration cycle Unit installation Understanding of safety features / Unit operation / Use during steady state / Understanding of refrigerating cycle via visualisation of changes of states Use of enthalpy chart Plot the different points of measurements / Trace of the real refrigeration cycle / Deduction of enthalpies at characteristic points / Determination of sub-cooling, overheat Measurement of thermal power Thermal power of condenser, evaporator and compressor Efficiencies, Global coefficient of performance DRAWING - DESIGNATION - Hermétic compressor, refrigeration power 200W - High and low pressure switch - Safety valve 15b - Oil separator - Water condenser and evaporator, shell in glass and copper coil tubes – Exchange area: 425 cm² - Filter, Drier, Thermostatic expansion valve with internal pressure equalization - High and Low pressure manometers with temperature scale, Cl. 1 - Temperature probes Pt100Ω at 0°C, Cl. B - Multi-ways temperature indicator - Refrigerating fluid flowmeter - Water flowmeter with needle valve on each water circuit (Condenser on evaporator) - Voltage and consumed intensity measurement 230V-1~50/ 60Hz-16A 50 L/H Evac. Dimensions: 980 x 460 x H690 - Weight: 50Kg Options for this product are listed on next page.
Transcript
Page 1: MCFC 10 - erides.fr · FT MCFC 10 Rev. B MCFC 10 Refrigeration cycle demonstration unit USE The equipment is composed of a transparent unit edged with anodised aluminium and elevated

ERIDĒSLA GRAND'OURSE16 rue Jean Sébastien BACH42000 SAINT-ETIENNE

04 77 530 53004 77 532 [email protected]

ERIDES reserves the right to make any necessary changes to the details contained in this notice. FT MCFC 10 Rev. B

MCFC 10Refrigeration cycle demonstration unit

USEThe equipment is composed of a transparent unit edged withanodised aluminium and elevated on feet. The transparent wallsallow visibility on all sides whilst protecting both the equipment andits users. Once plugged in and connected to the water input andoutput, the machine works automatically. The visible condensationand evaporation allow for the understanding of the cycle processes.Once the machine has reached steady state, measurements can betaken and can be used even after the machine has been turned off.The fluid used is R134a which is universally accepted by the newEuropean regulation.The regulation is controlled by a thermostatic expansion valve ofequalized internal pressure. The unit allows for measurement offlow rate, pressure, temperature and more, depending on theoption chosen. The fluid enthalpy chart is transposed onto atransparency at the centre of the unit allowing for rapid analysis ofthe fluid state parameters at any given point.

EDUCATIONAL CAPABILITIESStudy of the concept of vapour compressionrefrigerationCase of hermetic compressor / Fluide used: R134a /Sizing of components / Plot of theoretical refrigeration cycleUnit installationUnderstanding of safety features / Unit operation / Useduring steady state / Understanding of refrigerating cyclevia visualisation of changes of states

Use of enthalpy chartPlot the different points of measurements / Trace of the realrefrigeration cycle / Deduction of enthalpies at characteristicpoints / Determination of sub-cooling, overheatMeasurement of thermal powerThermal power of condenser, evaporator and compressorEfficiencies, Global coefficient of performance

DRAWING - DESIGNATION- Hermétic compressor, refrigeration power 200W- High and low pressure switch- Safety valve 15b - Oil separator- Water condenser and evaporator, shell in glass and coppercoil tubes – Exchange area: 425 cm²- Filter, Drier, Thermostatic expansion valve with internalpressure equalization- High and Low pressure manometers with temperature scale,Cl. 1- Temperature probes Pt100Ω at 0°C, Cl. B- Multi-ways temperature indicator- Refrigerating fluid flowmeter- Water flowmeter with needle valve on each water circuit(Condenser on evaporator)- Voltage and consumed intensity measurement

230V-1~50/60Hz-16A

50 L/H Evac.

Dimensions: 980 x 460 x H690 - Weight: 50Kg

Options for this product are listed on next page.

Page 2: MCFC 10 - erides.fr · FT MCFC 10 Rev. B MCFC 10 Refrigeration cycle demonstration unit USE The equipment is composed of a transparent unit edged with anodised aluminium and elevated

ERIDĒSLA GRAND'OURSE16 rue Jean Sébastien BACH42000 SAINT-ETIENNE

04 77 530 53004 77 532 [email protected]

ERIDES reserves the right to make any necessary changes to the details contained in this notice. FT MCFC 10 Rev. B

MCFC 10Refrigeration cycle demonstration unit

OPTION REAL-TIME REFRIGARATING CYCLE PLOT Ref. MCFC 10_LOG- Addition of extra pressure and temperature sensors- Acquisition of pressure and temperature measurements needed for cycle plot on PC- Software for real-time refrigerating cycle plot- USB connection

OPTION WATTMETER Ref. MCFC 10_WAT- Addition of a wattmeter displaying consumed compressor power in Watt

OPTION DATAS ACQUISITION Ref. MCFC 10_ACQ- Operation mode still possible in local (parameters display)- Addition of pressure sensors, temperature probes and analogic flowmeters- Addition of wattmeter displaying consumed compressor power in Watt- Acquisition cards and software on Labview- USB connection

OPTION SELF - MOBILE Ref. MCFC 10_AUT- Aluminium frame for supporting the equipment- 4 self directional castors with breake- 100 liters tank with drain valve- Submersible pump- With this option, no connection to water network and waste is needed


Recommended