+ All Categories
Home > Documents > MEASUREMENT AND INSTRUMENTATION K.ANISH Lecturer/EEE.

MEASUREMENT AND INSTRUMENTATION K.ANISH Lecturer/EEE.

Date post: 04-Jan-2016
Category:
Upload: edgar-holland
View: 232 times
Download: 4 times
Share this document with a friend
45
MEASUREMENT AND MEASUREMENT AND INSTRUMENTATION INSTRUMENTATION K.ANISH Lecturer/EEE
Transcript
Page 1: MEASUREMENT AND INSTRUMENTATION K.ANISH Lecturer/EEE.

MEASUREMENT AND MEASUREMENT AND INSTRUMENTATIONINSTRUMENTATION

K.ANISH

Lecturer/EEE

Page 2: MEASUREMENT AND INSTRUMENTATION K.ANISH Lecturer/EEE.

2

UNIT I Concepts of Measurement

Measurements( Ref 4, Chapter 1,pg no 1-11) Instrumentation( Ref 4, Chapter 1,pg no 1-11) Errors in measurements (Ref 4, Chapter 3,pg

no 60) Calibration Standard (Ref 4, Chapter 5,pg no 181)

Page 3: MEASUREMENT AND INSTRUMENTATION K.ANISH Lecturer/EEE.

3

Measurements

Measurement of a given quantity is essentially an act or result of comparison between the quantity (whose magnitude is unknown) and predetermined or predefined standards.

Two quantities are compared the result is expressed in numerical values.

Page 4: MEASUREMENT AND INSTRUMENTATION K.ANISH Lecturer/EEE.

4

Basic requirements for a meaningful measurement

The standard used for comparison purposes must be accurately defined and should be commonly accepted.

The apparatus used and the method adopted must be provable (verifiable).

Page 5: MEASUREMENT AND INSTRUMENTATION K.ANISH Lecturer/EEE.

5

Significance Of Measurement

Importance of Measurement is simply and eloquently expressed in the following statement of famous physicist Lord Kelvin: ”I often say that when you can measure what you are speaking about and can express it in numbers, you know something about it; when you cannot express in it numbers your knowledge is of meager and unsatisfactory kind”

Page 6: MEASUREMENT AND INSTRUMENTATION K.ANISH Lecturer/EEE.

6

Two major functions of all branch of engineering

Design of equipment and processes Proper Operation and maintenance of

equipment and processes.

Page 7: MEASUREMENT AND INSTRUMENTATION K.ANISH Lecturer/EEE.

7

Methods of Measurement

Direct Methods

Indirect Methods

Page 8: MEASUREMENT AND INSTRUMENTATION K.ANISH Lecturer/EEE.

8

DIRECT METHODS: In these methods, the unknown quantity (called the measurand ) is directly compared against a standard.

INDIRECT METHOD: Measurements by direct methods are not always possible, feasible and practicable. In engineering applications measurement systems are used which require need of indirect method for measurement purposes.

Page 9: MEASUREMENT AND INSTRUMENTATION K.ANISH Lecturer/EEE.

9

Instruments and Measurement Systems.

Measurement involve the use of instruments as a physical means of determining quantities or variables.

Because of modular nature of the elements within it, it is common to refer the measuring instrument as a MEASUREMENT SYSTEM.

Page 10: MEASUREMENT AND INSTRUMENTATION K.ANISH Lecturer/EEE.

10

Evolution of Instruments.

a) Mechanical b)Electrical c) Electronic Instruments. MECHANICAL: These instruments are

very reliable for static and stable conditions. But their disadvantage is that they are unable to respond rapidly to measurements of dynamic and transient conditions.

Page 11: MEASUREMENT AND INSTRUMENTATION K.ANISH Lecturer/EEE.

11

Contd

ELECTRICAL: It is faster than mechanical, indicating the output are rapid than mechanical methods. But it depends on the mechanical movement of the meters. The response is 0.5 to 24 seconds.

ELECTRONIC: It is more reliable than other system. It uses semiconductor devices and weak signal can also be detected.

Page 12: MEASUREMENT AND INSTRUMENTATION K.ANISH Lecturer/EEE.

12

Classification Of Instruments Absolute Instruments. Secondary Instruments.

ABSOLUTE: These instruments give the magnitude if the quantity under measurement terms of physical constants of the instrument.SECONDARY: These instruments are calibrated by the comparison with absolute instruments which have already been calibrated.

Page 13: MEASUREMENT AND INSTRUMENTATION K.ANISH Lecturer/EEE.

13

Further its classified as

Deflection Type Instruments

Null Type Instruments.

Page 14: MEASUREMENT AND INSTRUMENTATION K.ANISH Lecturer/EEE.

14

Functions of instrument and measuring system can be classified into three. They are:

i) Indicating function.

ii) Recording function.

iii) Controlling function. Application of measurement systems are:

i) Monitoring of process and operation.

ii) Control of processes and operation.

iii) Experimental engineering analysis.

Page 15: MEASUREMENT AND INSTRUMENTATION K.ANISH Lecturer/EEE.

15

Types Of Instrumentation System

Intelligent Instrumentation (data has been refined for the purpose of presentation )

Dumb Instrumentation (data must be processed by the observer)

Page 16: MEASUREMENT AND INSTRUMENTATION K.ANISH Lecturer/EEE.

16

Elements of Generalized Measurement System

Primary sensing element. Variable conversion element. Data presentation element. PRIMARY SENSING ELEMENT: The

quantity under measurement makes its first contact with the primary sensing element of a measurement system.

VARIABLE CONVERSION ELEMENT: It converts the output of the primary sensing element into suitable form to preserve the information content of the original signal.

Page 17: MEASUREMENT AND INSTRUMENTATION K.ANISH Lecturer/EEE.

17

Contd..

DATA PRESENTATION ELEMENT: The information about the quantity under measurement has to be conveyed to the personnel handling the instrument or the system for monitoring, control or analysis purpose.

Page 18: MEASUREMENT AND INSTRUMENTATION K.ANISH Lecturer/EEE.

18

Functional Elements of an Instrumentation System

PRIMARY SENSING ELEMENT

VARIABLE CONVER-SION ELEMENT

VARIABLE MANIPULATI-ON ELEMENT

DATA TRANSMISSIO-N ELEMENT

DATA CONDITIONING ELEMENT

INTERMEDIATE STAGE DETECTOR TRANSDUCER STAGE

TERMINATING STAGE

QUANTITY TO BE MEASURED

DATA PRESENTATION ELEMENT

Page 19: MEASUREMENT AND INSTRUMENTATION K.ANISH Lecturer/EEE.

19

Static Characteristics Of Instruments And Measurement

Systems ( Ref 4, Chapter 2) Application involved measurement of

quantity that are either constant or varies slowly with time is known as static.

AccuracyDriftDead Zone Static ErrorSensitivityReproducibility

Page 20: MEASUREMENT AND INSTRUMENTATION K.ANISH Lecturer/EEE.

20

Static Characteristics

Static correctionScale rangeScale spanNoiseDead TimeHysteresis.Linearity

Page 21: MEASUREMENT AND INSTRUMENTATION K.ANISH Lecturer/EEE.

21

ACCURACY: It is the closeness with an instrument reading approaches the true value of the quantity being measured.

TRUE VALUE: True value of quantity may be defined as the average of an infinite no. of measured value.

SENSITIVITY is defined as the ratio of the magnitude of the output response to that of input response.

Page 22: MEASUREMENT AND INSTRUMENTATION K.ANISH Lecturer/EEE.

22

STATIC ERROR: It is defined as the difference between the measured value and true value of the quantity.

A=Am-At

Where Am =measured value of quantity

At =true value of quantity.

It is also called as the absolute static error.

Page 23: MEASUREMENT AND INSTRUMENTATION K.ANISH Lecturer/EEE.

23

SCALE RANGE: The scale range of an instrument is defined as the difference between the largest and the smallest reading of the instrument.

Suppose highest point of calibration is Xmax units while the lowest is Xmin units, then the instrument range is between Xmin and Xmax.

SCALE SPAN: Scale span or instrument span is given as Scale span= Xmax - Xmin

It is the difference between highest and lowest point of calibration.

Page 24: MEASUREMENT AND INSTRUMENTATION K.ANISH Lecturer/EEE.

24

Reproducibility is specified in terms of scale readings over a given period of time.

Drift is an undesirable quality in industrial instruments because it is rarely apparent and cannot be maintained.

It is classified as

a) Zero drift

b) Span drift or sensitivity drift

c) Zonal drift.

Page 25: MEASUREMENT AND INSTRUMENTATION K.ANISH Lecturer/EEE.

25

Noise

A spurious current or voltage extraneous to the current or voltage of interest in an electrical or electronic circuit is called noise.

Page 26: MEASUREMENT AND INSTRUMENTATION K.ANISH Lecturer/EEE.

26

Noise

Generated Noise

Conducted Noise

Radiated Noise

Page 27: MEASUREMENT AND INSTRUMENTATION K.ANISH Lecturer/EEE.

27

Dynamic Characteristics of Measurement System

( Ref 4, Chapter 4)

• Speed of response

• Measuring lag

• Fidelity

• Dynamic error

Page 28: MEASUREMENT AND INSTRUMENTATION K.ANISH Lecturer/EEE.

28

. SPEED OF RESPONSE :It is defined as

the rapidity with which a measurement system responds to changes in measured quantity. It is one of the dynamic characteristics of a measurement system.

FIDELITY: It is defined as the degree to which a measurement system indicates changes in the measured quantity without any dynamic error.

Page 29: MEASUREMENT AND INSTRUMENTATION K.ANISH Lecturer/EEE.

29

Dynamic Error

It is the difference between the true value of the quantity changing with time and the value indicated by the measurement system if no static error is assumed. It is also called measurement error. It is one the dynamic characteristics.

Page 30: MEASUREMENT AND INSTRUMENTATION K.ANISH Lecturer/EEE.

30

Measuring Lag

It is the retardation delay in the response of a measurement system to changes in the measured quantity. It is of 2 types:

Retardation type: The response begins immediately after a change in measured quantity has occurred.

Time delay: The response of the measurement system begins after a dead zone after the application of the input.

Page 31: MEASUREMENT AND INSTRUMENTATION K.ANISH Lecturer/EEE.

31

Errors in Measurement Limiting Errors (Guarantee Errors) Known Error

Classification

Gross Error

Systematic Or Cumulative Error

Random Or Residual Or Accidental Error

Instrumental Environmental Observational

Page 32: MEASUREMENT AND INSTRUMENTATION K.ANISH Lecturer/EEE.

32

Gross Error Human Mistakes in reading , recording and

calculating measurement results. The experimenter may grossly misread the

scale. E.g.: Due to oversight instead of 21.5oC,

they may read as 31.5oC

They may transpose the reading while recording (like reading 25.8oC and record as 28.5oC)

Page 33: MEASUREMENT AND INSTRUMENTATION K.ANISH Lecturer/EEE.

33

Systematic Errors INSTRUMENTAL ERROR: These errors arise

due to 3 reasons-• Due to inherent short comings in the

instrument• Due to misuse of the instrument• Due to loading effects of the instrument

ENVIRONMENTAL ERROR: These errors are due to conditions external to the measuring device. These may be effects of temperature, pressure, humidity, dust or of external electrostatic or magnetic field.

OBSERVATIONAL ERROR: The error on account of parallax is the observational error.

Page 34: MEASUREMENT AND INSTRUMENTATION K.ANISH Lecturer/EEE.

34

Residual error

This is also known as residual error. These errors are due to a multitude of small factors which change or fluctuate from one measurement to another. The happenings or disturbances about which we are unaware are lumped together and called “Random” or “Residual”. Hence the errors caused by these are called random or residual errors.

Page 35: MEASUREMENT AND INSTRUMENTATION K.ANISH Lecturer/EEE.

35

Arithmetic Mean

The most probable value of measured variable is the arithmetic mean of the number of readings taken.

It is given by

Where = arithmetic mean x1,x2,.. x3= readings of samples n= number of readings

n

x

n

xxxx n

.....21

x

Page 36: MEASUREMENT AND INSTRUMENTATION K.ANISH Lecturer/EEE.

36

Deviation Deviation is departure of the observed reading

from the arithmetic mean of the group of readings.

0

)...(

)(..)()()(

0.....

321

321

321

33

22

11

XnXn

Xnxxxx

XxXxXxXx

ie

dddd

Xxd

Xxd

Xxd

Xxd

n

n

n

nn

Page 37: MEASUREMENT AND INSTRUMENTATION K.ANISH Lecturer/EEE.

37

Standard Deviation

The standard deviation of an infinite number of data is defined as the square root of the sum of the individual deviations squared divided by the number of readings.

nobservation

d

n

ddddsDS

nobservation

d

n

ddddDS

2011

....

20...

.

224

23

22

21

224

23

22

21

Page 38: MEASUREMENT AND INSTRUMENTATION K.ANISH Lecturer/EEE.

38

Variance

nobservation

dsDSVariance

nobservation

dDSVariance

201

.

20

.

222

222

Page 39: MEASUREMENT AND INSTRUMENTATION K.ANISH Lecturer/EEE.

39

Probable Error

Probable error of one reading(r1)=0.6745s

Probable error of mean (rm)

11

n

rrm

Page 40: MEASUREMENT AND INSTRUMENTATION K.ANISH Lecturer/EEE.

40

Problem

Question: The following 10 observation were recorded when measuring a voltage:

41.7,42.0,41.8,42.0,42.1,

41.9,42.0,41.9,42.5,41.8 volts.

1. Mean

2. Standard Deviation

3. Probable Error

4. Range.

Page 41: MEASUREMENT AND INSTRUMENTATION K.ANISH Lecturer/EEE.

41

Answer

Mean=41.97 volt S.D=0.22 volt Probable error=0.15 volt Range=0.8 volt.

Page 42: MEASUREMENT AND INSTRUMENTATION K.ANISH Lecturer/EEE.

42

Calibration

Calibration of all instruments is important since it affords the opportunity to check the instruments against a known standard and subsequently to find errors and accuracy.

Calibration Procedure involve a comparison of the particular instrument with either

a Primary standard a secondary standard with a higher accuracy than

the instrument to be calibrated. an instrument of known accuracy.

Page 43: MEASUREMENT AND INSTRUMENTATION K.ANISH Lecturer/EEE.

43

Standards

A standard is a physical representation of a unit of measurement. The term ‘standard’ is applied to a piece of equipment having a known measure of physical quantity.

Page 44: MEASUREMENT AND INSTRUMENTATION K.ANISH Lecturer/EEE.

44

Types of Standards – International Standards (defined based

on international agreement )

– Primary Standards (maintained by national standards laboratories)

– Secondary Standards ( used by industrial measurement laboratories)

– Working Standards ( used in general laboratory)

Page 45: MEASUREMENT AND INSTRUMENTATION K.ANISH Lecturer/EEE.

45

THANK YOU


Recommended