+ All Categories
Home > Documents > Measurement of mesh tension on the L-chamber drift panels

Measurement of mesh tension on the L-chamber drift panels

Date post: 24-Feb-2016
Category:
Upload: hanh
View: 45 times
Download: 0 times
Share this document with a friend
Description:
Measurement of mesh tension on the L-chamber drift panels. Fabian Kuger December 10 th 2013 Weekly Micromegas meeting - CERN. Goal & Setup. Measure mesh tension, with respect to: absolute values (nominal value: 10 N/cm) in homogeneities / systematics Aspects not jet addressed - PowerPoint PPT Presentation
Popular Tags:
6
Measurement of mesh tension on the L-chamber drift panels Fabian Kuger December 10 th 2013 Weekly Micromegas meeting - CERN
Transcript
Page 1: Measurement of mesh tension on the L-chamber drift panels

Measurement of mesh tensionon the L-chamber drift panels

Fabian Kuger

December 10th 2013Weekly Micromegas meeting - CERN

Page 2: Measurement of mesh tension on the L-chamber drift panels

Goal & Setup

Dezember 10th 2013 MM Weekly Meeting - CERN 2

Measure mesh tension, with respect to:

• absolute values (nominal value: 10 N/cm)• in homogeneities / systematics

Aspects not jet addressed

• influence of spacer gluing process• QC of delivered, pre-stretched meshes• influence of panel gluing process

Setup:• horizontal setup of the drift panel (mesh upside)• panel supported on left & right edge (Al-bars) • measuring every 20cm on 5 (equal-spaced) lines along the panel

Page 3: Measurement of mesh tension on the L-chamber drift panels

Instrument of measure

Dezember 10th 2013 MM Weekly Meeting - CERN 3

Reproducibility of all measurements on ±0.2 N/cm level

☒ Small drift gap leads to touching on the drift panel at some measurement points

Page 4: Measurement of mesh tension on the L-chamber drift panels

Panel L2-old (without spacers)

  left mid-left centermid-right right

   5 cm 26 cm 46 cm 66 cm 87 cm

5 cm 15.2 12.4 14.8 12.2 12.0

25 cm 13.8 12.4 13.4 11.8 10.8

45 cm 12.4 11.6 12.2 10.8 10.0

65 cm 13.4 12.4 12.6 11.6 10.6

85 cm 13.0 12.4 12.4 11.4 10.6

105 cm 13.2 12.0 13.6 10.8 10.4

125 cm 12.2 11.2 12.0 10.8 10.2

145 cm 14.0 11.8 12.0 11.0 10.6

165 cm 13.2 11.2 12.2 11.0 10.2

185 cm 13.6 10.4 11.2 10.8 10.4

205 cm 17.0 10.6 13.0 11.8 13.2

Results L2 (old)

Dezember 10th 2013 MM Weekly Meeting - CERN 4

Page 5: Measurement of mesh tension on the L-chamber drift panels

Panel 2 (L3) - with 3 spacers

  left mid-left centermid-right right

   5 cm 26 cm 46 cm 66 cm 87 cm

5 cm 13.6 10.8 12.2 13.8 16.6

25 cm 11.0 10.6 10.8 12.4 14.0

45 cm 9.0 12.4 10.2 12.2 10.2

65 cm 10.6 12.0 12.6 12.2 12.6

85 cm 12.0 12.0 11.8 13.0 13.8

105 cm 12.2 11.0 10.4 13.6 15.0

125 cm 10.4 11.2 11.8 11.6 12.0

145 cm 9.4 11.6 10.8 11.8 12.2

165 cm 9.8 12.2 10.2 11.8 11.2

185 cm 9.6 12.0 12.4 11.2 12.2

205 cm 10.2 9.2 10.2 11.6 12.0

Results L3

Dezember 10th 2013 MM Weekly Meeting - CERN 5

Page 6: Measurement of mesh tension on the L-chamber drift panels

• Re-measure L2 panel after spacer gluing Influence of spacer gluing process?

• Measure the pre-stretched meshes for MSW Enables us to measure influence of panel gluing

process during MSW production

• Need to agree on upper / lower limits for mesh tension Ideas of how to proceed & help are highly welcome