membrane elements - industrial applications Water Technologies & Solutions manual Find a contact near you by visiting www.suezwatertechnologies.com and clicking on “Contact Us.” *Trademark of SUEZ; may be registered in one or more countries. ©2019 SUEZ. All rights reserved. IndustrialCatalog.docx Jan-19
Transcript
Page 1: membrane elements - industrial applications · Membrane flux (water permeability constant) is designated by a letter in position 2. Some membrane types, such A-Series and D-Series,

membrane elements - industrial applications

Water Technologies & Solutions

manual

Find a contact near you by visiting www.suezwatertechnologies.com and clicking on “Contact Us.”

*Trademark of SUEZ; may be registered in one or more countries.

©2019 SUEZ. All rights reserved.

IndustrialCatalog.docx Jan-19

Page 2: membrane elements - industrial applications · Membrane flux (water permeability constant) is designated by a letter in position 2. Some membrane types, such A-Series and D-Series,

Page 2 IndustrialCatalog.docx

contents CONTENTS 1

MEMBRANE ELEMENTS 3

THE FOUR MEMBRANE PROCESSES 4

MEMBRANE MATERIALS 4

INTEGRAL MEMBRANES 4

COMPOSITE MEMBRANES 5

MEMBRANE STRUCTURE 5

MEMBRANE MODULE 5

PRODUCT INFORMATION 6

NOMENCLATURE 7

ELEMENT NOMENCLATURE 7

CAGE VS. FIBERGLASS 8

SHIPPING INFORMATION 8

PRODUCT SELECTION GUIDE 9

PRODUCTS BY MEMBRANE TYPE 10

ACID RECOVERY 10

“HEAVY DUTY” INDUSTRIAL APPLICATIONS 10

HIGH TEMPERATURE APPLICATIONS 11

WATER RECLAMATION APPLICATIONS 11

ORDERING INFORMATION 12

REVERSE OSMOSIS ELEMENTS 13

NANOFILTRATION ELEMENTS 13

ULTRAFILTRATION ELEMENTS 14

MICROFILTRATION ELEMENTS 15

ACID RECOVERY 16

“HEAVY DUTY” INDUSTRIAL APPLICATIONS 16

HIGH TEMPERATURE SANITIZATION AND OPERATION 17

WATER RECLAMATION APPLICATIONS 18

SPARE PARTS 19

GLOSSARY 20

ORDERING PARTS 21

ACCESSORY KITS 21

CONTACT CUSTOMER CARE 25

HAVE A WATER EMERGENCY? 26

Page 3: membrane elements - industrial applications · Membrane flux (water permeability constant) is designated by a letter in position 2. Some membrane types, such A-Series and D-Series,

IndustrialCatalog.docx Page 3

membrane elements

Page 4: membrane elements - industrial applications · Membrane flux (water permeability constant) is designated by a letter in position 2. Some membrane types, such A-Series and D-Series,

Page 4 IndustrialCatalog.docx

the four membrane processes Reverse Osmosis (RO) is the tightest possible membrane process in liquid/liquid separation. Water is, in

principle, the only material passing through the membrane; essentially all dissolved and suspended material

is rejected. The more open types of RO membranes are sometimes confused with nanofiltration (NF).

True NF combines two rejection mechanisms; one based on molecular weight or size and shape of the molecule

(regardless of the ionic charge), the other is based on electrical repulsion between the negatively charged

membrane and the anionic species of the salt present in solution. NF highly rejects (min 96% rejection)

multivalent salts such as magnesium sulfate (MgSO4) regardless of the feed concentration. It will also reject

monovalent salts, such as sodium chloride, but only between 0-50% depending on the feed concentration. In

contrast, “loose RO” is a RO membrane with reduced salt rejection of all salts (monovalent and multivalent).

Ultrafiltration (UF) is a process where the high molecular weight compounds are concentrated, such as protein,

and undesirable substances (ie salts or amino acids or simple sugars) permeate through the membrane due to

their small molecular weight. Ultrafiltration can also be used for pyrogen removal in ultrapure water systems.

Microfiltration (MF) is a clarification process where suspended solids, fats and very large organics are rejected.

membrane materials The selection of membranes offered by the various suppliers in the business may appear to be confusing since

many materials may be used to make membranes, and they are provided under an array of trade names. In

reality, relatively few materials are actually used in quantity, and only a few basic membrane types form the

bulk of the membranes being sold and used.

integral membranes

Cellulose acetate (CA) is the “original” membrane and is used for RO, NF and UF applications. The material has

a number of limitations, mostly with respect to pH and temperature. The main advantage of CA is its low price,

and the fact that it is hydrophilic, which makes it less prone to fouling. There are many “die hard” membrane

users who insist on buying “the same membrane as last time,” and who simply stay with CA because it works

for them. An inherent weakness of CA is that is can be eaten by microorganisms.

Polysulfone (PSO) in a number of varieties has been used for UF and MF membrane since 1975. PSO’s main

advantage is its exceptional temperature and pH resistance. PSO is practically the only membrane material

used in high quantity for a number of food and dairy applications. As a rule, PSO membranes do not tolerate oil,

grease, fat and polar solvents. However, there is one type of hydrophilic PSO membrane which apparently defies

this rule and seems to work well with oil emulsions.

Polyvinylidenedifluoride (PVDF) is a traditional membrane material, but it is not used much because it is difficult

to make membranes with good and consistent separation characteristics. Its main advantage is its high

resistance to hydrocarbons and oxidizing environments.

Page 5: membrane elements - industrial applications · Membrane flux (water permeability constant) is designated by a letter in position 2. Some membrane types, such A-Series and D-Series,

IndustrialCatalog.docx Page 5

composite membranes

Composites membranes, also called thin-film composite

membranes, appear under various acronyms such as TFC

(thin-film composite) and TFM (thin-film membrane), and were

made to replace cellulose acetate (CA) RO membranes. The

main advantage is the combination of relatively high flux and

very high salt rejection. Composite RO membranes commonly

reject 99.5% NaCl. They also have good temperature and pH

resistance, but do not tolerate oxidizing environments.

Composite membranes are made in two-layer and three-layer

designs, the precise composition of which is proprietary.

Generally speaking, a thin-film composite membrane consists of a PS membrane as support for the very thin

skin layer which is polymerized in situ on the PS UF membrane. The three layer design has two thin film

membranes on top of the PS support membrane.

membrane structure All RO, NF and UF membranes are asymmetric. This differentiates most membranes from common filters, e.g.

coffee filters, which are symmetric or, in other words, are identical on both sides of the filter. Membranes have

a tight top layer facing the product to be treated. This layer is also called the skin layer. It is thin, typically < 0.1

micron. The membrane itself is approximately 150 - 250 micron where the bulk of the membrane provides

structural support for the skin layer. The asymmetric structure means that the pores are wider as you move

farther away from the surface, which prevents the pores from plugging. This provides good fouling resistance,

since foulants have a tendency to either be totally rejected or to pass all the way through a membrane.

membrane module The spiral wound element type is the workhorse in the membrane world. The spiral wound element design was

originally made exclusively for water desalination, but the very compact design and the low price made it

attractive to other industries. After a lot of trial and failure, redesigned elements emerged which can be used

for a variety of industrial applications in the dairy industry, the pulp and paper industry, for high purity water,

and at high temperature and extreme pH. However, the number of membrane companies who really can and

will develop and supply spiral wound elements for extreme applications is in many cases limited to one.

Page 6: membrane elements - industrial applications · Membrane flux (water permeability constant) is designated by a letter in position 2. Some membrane types, such A-Series and D-Series,

Page 6 IndustrialCatalog.docx

product information

Page 7: membrane elements - industrial applications · Membrane flux (water permeability constant) is designated by a letter in position 2. Some membrane types, such A-Series and D-Series,

IndustrialCatalog.docx Page 7

nomenclature

element nomenclature

The element nomenclature consists of a 6-position base model designation. There may be exceptions to the

nomenclature. As an example: DK8040F30

Nomenclature

1 2 3 4 5 6

D K 80 40 F 30

Membrane Type Membrane Flux Diameter Length Outer wrap Spacer

Position 1 DK8040F30. The product membrane family is designated by a letter/word in position 1. In the

example shown, the letter D designates D-Series thin-film membrane. Other membrane types are described

below.

Position 1

Membrane Product Type

S RO S-Series TFM

D NF D-Series TFM

G UF G-Series TFM

P UF P-Series PES

M UF M-Series PAN

J MF J-Series PVDF

DURACID NF K-Series TFM

INDUSTRIAL RO, NF S-Series, A-Series, D-Series TFM

DURATHERM HWS RO, NF A-Series, D-Series TFM

DURATHERM EXL RO, NF, UF D-Series, G-Series, S-Series TFM

DURATHERM STD RO, UF A-Series, P-Series TFM, PES

DURASLICK RO, NF D-Series, S-Series TFM

Position 2 DK8040F30. Membrane flux (water permeability constant) is designated by a letter in position 2.

Some membrane types, such A-Series and D-Series, may have multiple flux models and, therefore, several

different flux letters. Flux codes range from A to Z, with A representing the lowest water permeability constant.

Positions 3 DK8040F30. The element diameter in inches is designated by position 3. In the example shown, the

D-Series element is 8.0 inches in diameter.

Positions 4 DK8040F30. Element length in inches is designated by position 4. In the example shown, element

length is 40 inches.

Position 5 DK8040F30. Element outer wrap is designated by position 5. In the example shown, F refers to

fiberglass. Other possibilities include:

Position 5

Wrap

F Fiberglass

C Cage

Position 6 DK8040F30. Element spacer is designated by position 6. In the example shown, the 6th position

indicates elements having a 30 mil spacer for a low solids application.

Position 6

Spacer (mm)

30 30mil (0.76)

35 35mil (0.89)

50 50mil (1.27)

Page 8: membrane elements - industrial applications · Membrane flux (water permeability constant) is designated by a letter in position 2. Some membrane types, such A-Series and D-Series,

Page 8 IndustrialCatalog.docx

cage vs. fiberglass

Cage outer wrap eliminates the voids and dead spaces inside the membrane housing. Industrial caged elements

have glued-on ATD’s where a brine seal may be used in order to have a restricted by-pass around the element.

All Duratherm elements are caged. When using caged elements higher feed flows are required to achieve

sufficient turbulences inside the element, and an adequate pressure drop.

Fiberglass (FRP) element casings eliminate by-pass and optimize the energy consumption of the recirculation

pump. They are engineered to be compatible with high pressure operations.

shipping information

Female connection with ATD Male connection with ATD

Shipping Information

Size1 Connection Dimension Inches (cm) Boxed Weight lbs. (kg)

A B2 C3 Dry

2540 Male 40.00 (101.6) 0.75 (1.9) OD 2.4 (6.1) 4 (1.8)

4025 Female 40.00 (101.6) 0.625 (1.6) 3.9 (9.8) 5 (2.3)

4040C4 Female 38.75 (98.4) 0.625 (1.6) 3.98 (10.1) 8 (3.5)

4040F Male 40.00 (101.6) 0.75 (1.9) OD 3.9 (9.8) 9 (4.1)

8040 Female 40.00 (101.6) 1.125 (2.85) 7.9 (20.1) 29 (13.2)

8340 Female 40.00 (101.6) 1.138 (2.89) 8.3 (21.1) 42 (19.1)

1 These elements are shipped dry/dried unless specified wet.

2 Internal diameter unless specified OD (outside diameter).

3 The element diameter (dimension C) is designed for optimum performance in SUEZ pressure vessels. Others pressure

vessel dimension and tolerance may result in excessive bypass and loss of capacity.

4 The length listed in the table above is the element length without ATD installed. These elements are provided with

interconnectors used to connect consecutive elements when installed in multiple element housings. Every element is

delivered with a kit containing 1 Interconnector (0.75” long), 8 O-rings and 2 Anti Telescoping Devices (0.25” wide). When

the element, ATD’s and interconnector are all in place the element measures 40”.

Page 9: membrane elements - industrial applications · Membrane flux (water permeability constant) is designated by a letter in position 2. Some membrane types, such A-Series and D-Series,

IndustrialCatalog.docx Page 9

product selection guide

Page 10: membrane elements - industrial applications · Membrane flux (water permeability constant) is designated by a letter in position 2. Some membrane types, such A-Series and D-Series,

Page 10 IndustrialCatalog.docx

Membrane protection matters – to better protect your membrane treatment system, SUEZ offers a line of the

industry’s best pre-filters. By providing the whole solution and not just portions of it, SUEZ helps our customers

extend membrane life and reduce operating costs. For more information on which SUEZ filters to use with

which SUEZ membranes, see below or talk with your SUEZ representative.

products by membrane type

Reverse osmosis elements

Material Rejection Size Outer wrap Spacer Max temp Chlorine tolerance

SE TFM 99% NaCl 2540 8040 Fiberglass Cage 30 50 50°C 500 ppm-hours

TFM: Thin Film Membrane

To protect your RO membranes, use ROSave.Z for 30mil spacer elements and ZCore (20micron) for the 50mil spacer elements.

Nanofiltration elements

Material Rejection Size Outer wrap Spacer Max temp Chlorine tolerance

DK TFM 98% MgSO4 2540 4040 8040 Fiberglass Cage 30 50 50°C 500 ppm-hours

DL TFM 96% MgSO4 2540 4040 8040 Fiberglass Cage 30 50 50°C 500 ppm-hours

TFM: Thin Film Membrane

To protect your NF membranes, use ROSave.Z for 30mil spacer elements and ZCore (20micron) for the 50mil spacer elements.

Ultrafiltration elements

Material MWCO (Da) Size Outer wrap Spacer Max temp Chlorine tolerance

GE TFM 1,000 2540 4040 8040 Fiberglass Cage 30 50 50°C 20-50 ppm days

GH TFM 2,500 2540 4040 8040 Fiberglass Cage 30 50 50°C 20-50 ppm days

GK TFM 3,500 2540 4040 8040 Fiberglass Cage 30 50 50°C 1,000 ppm days

PT PES 5,000 8040 Fiberglass Cage 30 50 50°C 5,000 ppm days

PW PES 30,000 2540 4025 4040 8340 8040 Fiberglass Cage Tape 30 50 50°C 5,000 ppm-hours

MW PAN 50,000 2540 4040 8040 Fiberglass Cage 30 50 50°C 200,000 ppm-hours

TFM: Thin Film Membrane – PES: Polyethersulfone – PAN: Polyacrylonitrile

To protect your UF membranes, use ROSave.Z for 30mil spacer elements and ZCore (20micron) for the 50mil spacer elements.

Microfiltration elements

Material Pore Size (µ) Size Outer wrap Spacer Max temp Chlorine tolerance

JX PVDF 0.3 2540 4040 8040 Fiberglass Cage 30 50 50°C 5,000 ppm days

PS: Polysulfone – PVDF: Polyvinylidene Fluoride

To protect your MF membranes, ZCore (20micron) for the 50mil spacer elements.

acid recovery

Duracid

Material Rejection Size Outer wrap Spacer Max temp Chlorine tolerance

DURACID TFM 98% NaCl 2540 4040 8040 Fiberglass 30 35 70°C 500 ppm-hours

TFM: Thin Film Membrane

To protect your UF membranes, use ROSave.Z for 30mil spacer elements and ZCore (20micron) for the 50mil spacer elements.

“heavy duty” industrial applications

Industrial

Material Rejection Size Outer wrap Spacer Max temp Max operating pressure psi (bar) Chlorine tolerance

INDUSTRIAL

RO3

TFM 99.0% NaCl 4040 8040 Fiberglass 35 50 50°C 1200 (80) 500 ppm hours

INDUSTRIAL

RO5

TFM 99.5% NaCl 4040 8040 Fiberglass 35 50 50°C 1200 (80) 500 ppm hours

TFM: Thin Film Membrane

To protect your UF membranes, use ROSave.Z for 30mil spacer elements and ZCore (20micron) for the 50mil spacer elements.

Page 11: membrane elements - industrial applications · Membrane flux (water permeability constant) is designated by a letter in position 2. Some membrane types, such A-Series and D-Series,

IndustrialCatalog.docx Page 11

high temperature applications

The rejection characteristics of the Duratherm elements are dependent on temperature.

Duratherm HWS

Material Rejection Size Outer wrap Spacer Operating temp HWS temp Chlorine tolerance

RO HR TFM 99.5% 2540 4040 8040 Cage 30 50°C 90°C 500 ppm hours

RO TFM 99% 2540 4040 8040 Cage 30 50°C 90°C 500 ppm hours

NF TFM 99.5% 4040 8040 Cage 30 50°C 90°C 500 ppm hours

UF PES 30,000 Da 8040 Cage 30 50°C 90°C 5000 ppm hours

Duratherm STLD

Material Rejection Size Outer wrap Spacer Operating temp HWS temp Chlorine tolerance

RO TFM 99.5% 4040 8040 Cage 30 70°C 90°C 500 ppm hours

UF PES 5,000 Da 8040 Cage 30 70°C 90°C 5,000 ppm days

Duratherm EXL

Material Rejection Size Outer wrap Spacer Operating temp HWS temp Chlorine tolerance

RO HR TFM 99% 2540 4040 8040 Cage 50 70°C 90°C 500 ppm hours

NF HR TFM 99.5% 2540 4040 8040 Cage 50 70°C 90°C 500 ppm hours

NF TFM 99.5% 4040 8040 Cage 50 70°C 90°C 500 ppm hours

UF TFM 2,500 Da 8040 Cage 50 70°C 90°C 500 ppm days

HWS: Hot Water Sanitization

TFM: Thin Film Membrane

EXL: For process streams

STD: For water and condensate streams

To protect your UF membranes, use ROSave.Z for 30mil spacer elements and ZCore (20micron) for the 50mil spacer elements.

water reclamation applications

These membranes are used for secondary and tertiary effluent purification, organic load reduction and salt

removal to meet discharge regulations or industrial water needs such as cooling water.

Duraslick

Material Rejection Size Outer wrap Spacer Max temp Chlorine tolerance

RO TFM 98.6% NaCl 2540 4040 8040 Fiberglass 30 50°C 500 ppm-hours

NF TFM 98.6%

MgSO4

2540 4040 8040 Fiberglass 30 50°C 500 ppm-hours

TFM: Thin Film Membrane

To protect your UF membranes, use ROSave.Z for 30mil spacer elements and ZCore (20micron) for the 50mil spacer elements.

Page 12: membrane elements - industrial applications · Membrane flux (water permeability constant) is designated by a letter in position 2. Some membrane types, such A-Series and D-Series,

Page 12 IndustrialCatalog.docx

ordering information

Page 13: membrane elements - industrial applications · Membrane flux (water permeability constant) is designated by a letter in position 2. Some membrane types, such A-Series and D-Series,

IndustrialCatalog.docx Page 13

reverse osmosis elements The S-Series SE High Rejection Brackish Water Elements are used for brackish water desalination and process

stream concentration. The SE elements feature either a fiberglass or a patented Durasan* cage outer wrap,

30mil or 50mil spacer and polysulfone or Noryl plastic parts.

SE Elements

Model Average flow gpd (m3/day) Average NaCl rejection Active Area ft² (m²) Outer wrap Connection Spacer mil (mm) Part Number

SE2540F30 550 (2.1) 99% 28 (2.6) Fiberglass Male 30 (0.76) 1207431

SE2540F50 370 (1.4) 99% 22 (2,0) Fiberglass Male 50 (1.27) 1207427

SE8040C30 8,500 (32.2) 99% 374 (34,7) Cage Female 30 (0.76) 1207488

Testing conditions: 2,000mg/l NaCl solution at 425psi (2,930kPa) operating pressure, 77°F (25°C), pH 6.5 and 15% recovery

To protect your UF membranes, use ROSave.Z for 30mil spacer elements and ZCore (20micron) for the 50mil spacer elements.

nanofiltration elements The D-Series DK and DL family of proprietary thin-film nanofiltration membrane elements is characterized by

an approximate molecular weight cut-off of 150-300 Dalton for uncharged organic molecules with the ability to

permeate monovalent salts while retaining divalent ions. The DK and DL elements are used for applications

including brine purification, dye desalting /concentration, diluted acid purification and COD removal from

effluents.

DK Elements

Model Average flow gpd

(m3/day)

Average MgSO4

rejection

Active Area ft² (m²) Outer wrap Connection Spacer mil (mm) Part Number

DK2540C30 560 (2.1) 98% 24 (2.2) Cage Male 30 (0.76) 1206918

DK2540C50 350 (1.3) 98% 18 (1.6) Cage Male 50 (1.27) 1206919

DK2540F30 540 (2.0) 98% 28 (2.6) Fiberglass Male 30 (0.76) 1206925

DK2540F50 340 (1.3) 98% 22 (2,0) Fiberglass Male 50 (1.27) 1206926

DK4040C30 1,900 (7.2) 98% 89 (8.2) Cage Female 30 (0.76) 1206947

DK4040C50 1,400 (5.3) 98% 67 (6.2) Cage Female 50 (1.27) 1206946

DK4040F30 1,900 (7.2) 98% 85 (7.9) Fiberglass Male 30 (0.76) 3050075

DK4040F50 1,400 (5.3) 98% 66 (6,1) Fiberglass Male 50 (1.27) 3050073

DK8040C30

8,100 (30.7) 98% 374 (34,7) Cage Female 30 (0.76) 1206978

DK8040C50 6,500 (24.6) 98% 300 (27.9) Cage Female 50 (1.27) 1206979

DK8040F30 8,100 (30.7) 98% 364 (33.8) Fiberglass Female 30 (0.76) 1206993

DK8040F50 6,500 (24.6) 98% 284 (26.4) Fiberglass Female 50 (1.27) 1206994

Testing conditions: 2,000mg/l MgSO4 solution at 110psi (760kPa) operating pressure, 77°F (25°C), and 15% recovery.

To protect your UF membranes, use ROSave.Z for 30mil spacer elements and Zcore (20micron) for the 50mil spacer elements.

The DL nanofiltration elements are used in applications that require superior desalting efficiency and/or higher

fluxes compared to DK and when a higher passage in the permeate is acceptable.

DL Elements

Model Average flow gpd (m3/day) Average MgSO4 rejection Active Area ft² (m²) Outer wrap Connection Spacer mil (mm) Part Number

DL2540C50 430 (1.6) 96% 18 (1.7) Cage Male 50 (1.27) 1207015

DL2540F30 650 (2.5) 96% 28 (2.6) Fiberglass Male 30 (0.76) 1207018

DL2540F50 450 (1.7) 96% 22 (2,0) Fiberglass Male 50 (1.27) 1207019

DL4040C30 2,400 (9.1) 96% 89 (8.2) Cage Female 30 (0.76) 1207030

DL4040C50 1,800 (6.8) 96% 67 (6.2) Cage Female 50 (1.27) 1207028

DL4040F30 2,400 (9.1) 96% 85 (7.9) Fiberglass Male 30 (0.76) 3050068

DL4040F50 1,800 (6.8) 96% 66 (6,1) Fiberglass Male 50 (1.27) 3050067

DL8040C30 10,200 (38.6) 96% 374 (34,7) Cage Female 30 (0.76) 1207040

DL8040C50 8,200 (31.0) 96% 300 (27.9) Cage Female 50 (1.27) 1207041

DL8040F30 10,200 (38.6) 96% 364 (33.8) Fiberglass Female 30 (0.76) 1207048

DL8040F50 8,200 (31.0) 96% 284 (26.4) Fiberglass Female 50 (1.27) 1207049

Testing conditions: 2,000mg/l MgSO4 solution at 110psi (760kPa) operating pressure, 77°F (25°C), and 15% recovery.

To protect your UF membranes, use ROSave.Z for 30mil spacer elements and Zcore (20micron) for the 50mil spacer elements.

Page 14: membrane elements - industrial applications · Membrane flux (water permeability constant) is designated by a letter in position 2. Some membrane types, such A-Series and D-Series,

Page 14 IndustrialCatalog.docx

ultrafiltration elements The G-Series SUEZ family of proprietary thin-film ultrafiltration membrane elements is characterized by a

molecular weight cutoff of 1,000 on polyethylene glycol and a smooth, fouling resistant membrane surface.

SUEZ elements are used for precise fractionation of organic solutions.

GE Elements

Model MWCO (Dalton) Active Area ft² (m²) Outer wrap Connection Spacer mil (mm) Part Number

GE2540F30 1,000 28 (2.6) Fiberglass Male 30 (0.76) 1207086

GE2540F50 1,000 22 (2,0) Fiberglass Male 50 (1.27) 1207087

GE4040C50 1,000 67 (6.2) Cage Female 50 (1.27) 1207091

GE4040F30 1,000 85 (7.9) Fiberglass Male 30 (0.76) 3050063

GE8040F30 1,000 364 (33.8) Fiberglass Female 30 (0.76) 1207098

GE8040F50 1,000 284 (26.4) Fiberglass Female 50 (1.27) 1207096

Flux specification are based on fouling free water at 410psi (2,827kPa) operating pressure, 77°F (25°C), and 10% recovery.

To protect your UF membranes, use ROSave.Z for 30mil spacer elements and Zcore (20micron) for the 50mil spacer elements.

The G-Series GH family of proprietary thin-film ultrafiltration membrane elements is characterized by a

molecular weight cutoff of 2,500 on polyethylene glycol and a smooth, fouling resistant membrane surface. GH

membranes are used for color/TOC reduction and the removal of sulphate salts from organic solutions.

GH Elements

Model MWCO (Dalton) Active Area ft² (m²) Outer wrap Connection Spacer mil (mm) Part Number

GH2540C50 2,500 18 (1.7) Cage Male 50 (1.27) 1207101

GH2540F30 2,500 28 (2.6) Fiberglass Male 30 (0.76) 1207102

GH4040F30 2,500 85 (7.9) Fiberglass Male 50 (1.27) 3050061

GH4040F50 2,500 66 (6,1) Fiberglass Male 50 (1.27) 3050060

GH8040C30 2,500 374 (34,7) Cage Female 30 (0.76) 1207118

GH8040C50 2,500 300 (27.9) Cage Female 50 (1.27) 1207119

GH8040F30 2,500 364 (33.8) Fiberglass Female 30 (0.76) 1207120

GH8040F50 2,500 284 (26.4) Fiberglass Female 50 (1.27) 1207121

Flux specification are based on fouling free water at 160psi (1,103kPa) operating pressure, 77°F (25°C), and 10% recovery.

To protect your UF membranes, use ROSave.Z for 30mil spacer elements and Zcore (20micron) for the 50mil spacer elements.

The G-Series GK family of proprietary thin-film ultrafiltration membrane elements is characterized by a

molecular weight cutoff of 3,500 on polyethylene glycol and a smooth, fouling resistant membrane surface. GK

elements are used for chemical purification.

GK Elements

Model MWCO (Dalton) Active Area ft² (m²) Outer wrap Connection Spacer mil (mm) Part Number

GK2540F30 3,500 28 (2.6) Fiberglass Male 30 (0.76) 1207129

GK2540F50 3,500 22 (2,0) Fiberglass Male 50 (1.27) 1207130

GK4040F30 3,500 85 (7.9) Fiberglass Male 30 (0.76)) 3050009

GK4040F50 3,500 66 (6,1) Fiberglass Male 50 (1.27) 3050008

GK8040C50 3,500 300 (27.9) Cage Female 50 (1.27) 1207151

GK8040F30 3,500 364 (33.8) Fiberglass Female 30 (0.76) 1207152

GK8040F50 3,500 284 (26.4) Fiberglass Female 50 (1.27) 1207153

Flux specification are based on fouling free water at 85psi (586kPa) operating pressure, 77°F (25°C), and 10% recovery.

To protect your UF membranes, use ROSave.Z for 30mil spacer elements and Zcore (20micron) for the 50mil spacer elements.

The P-Series PT family of polyethersulfone ultrafiltration membrane elements is characterized by a 5,000

molecular weight cut-off. PT elements are typically used for fractionation of organics solutions in the chemical

industry.

PT Elements

Model MWCO (Dalton) Active Area ft² (m²) Outer wrap Connection Spacer mil (mm) Part Number

PT8040C50 5,000 264(24,5) Cage Female 50 (1.27) 1240574

PT8040F30 5,000 340 (31,6) Fiberglass Female 30 (0.76) 1229772

To protect your UF membranes, use ROSave.Z for 30mil spacer elements and ZCore (20micron) for the 50mil spacer elements.

Page 15: membrane elements - industrial applications · Membrane flux (water permeability constant) is designated by a letter in position 2. Some membrane types, such A-Series and D-Series,

IndustrialCatalog.docx Page 15

The P-Series PW family of polyethersulfone ultrafiltration membrane elements is characterized by a 30,000

molecular weight cut-off and greater than 96% rejection of Cytochrome-C (13,200 MC protein). PW elements

are used for pretreatment of process water and post treatment of ultrapure water.

PW Elements

Model MWCO (Dalton) Active Area ft² (m²) Outer wrap Connection Spacer mil (mm) Part Number

PW2540C30 30,000 23 (2,1) Cage Male 30 (0.76) 1207350

PW2540F30 30,000 28 (2.6) Fiberglass Male 30 (0.76) 1207352

PW2540F50 30,000 22 (2,0) Fiberglass Male 50 (1.27) 1207351

PW4025T 30,000 50 (4.6) Tape Female 50 (1.27) 1207369

PW4040C30 30,000 82 (7,6) Cage Female 30 (0.76) 1207372

PW4040C50 30,000 63 (5.8) Cage Female 50 (1.27) 1207371

PW4040F30 30,000 79 (7.3) Fiberglass Male 30 (0.76 3050051

PW8040C50 30,000 264 (24.5) Cage Female 50 (1.27) 1207399

PW8040F30 30,000 340 (31,6) Fiberglass Female 30 (0.76) 1207404

PW8040F50 30,000 269 (25.0) Fiberglass Female 50 (1.27) 1207403

PW8340C50 30,000 276 (25,6) Cage Female 50 (1.27) 1223936

To protect your UF membranes, use ROSave.Z for 30mil spacer elements and ZCore (20micron) for the 50mil spacer elements.

The M-Series MW family of polyacrylonitrile ultrafiltration membrane elements have been engineered to be

extremely hydrophilic (water attracting) as compared to conventional membranes that are oleophilic (oil

attracting) to avoid fouling by “free” oils. MW Elements are used to remove emulsified oil from water,

concentrate oily effluents and to protect RO or NF from oil spills. MW elements can be operated on hot

emulsions and produced water up to 75˚C. They typically require some form of mechanical pretreatment to

remove free oil and gross solids.

MW Elements

Model MWCO (Dalton) Active Area ft² (m²) Outer wrap Connection Spacer mil (mm) Part Number

MW2540F30 50,000 28 (2.6) Fiberglass Male 30 (0.76) 1233383

MW4040F50 50,000 62 (5,8) Fiberglass Male 50 (1.27) 3050562

MW8040C50 50,000 264 (24.7) Cage Female 50 (1.27) 1220654

MW8040F50 50,000 269 (25.0) Fiberglass Female 50 (1.27) 1229852

To protect your UF membranes, use ROSave.Z for 30mil spacer elements and ZCore (20micron) for the 50mil spacer elements.

microfiltration elements The J-Series JX family of polyvinylidene fluoride microfiltration membrane elements is used for process stream

clarification and electro-deposition paint concentration.

JX Elements

Model Pore Size (µ) Active Area ft² (m²) Outer wrap Connection Spacer mil (mm) Part Number

JX2540F30 0.3 28 (2.6) Fiberglass Male 30 (0.76) 1207253

JX2540F50 0.3 22 (2,0) Fiberglass Male 50 (1.27) 1207252

JX4040C30 0.3 82 (7,6) Cage Female 30 (0.76) 1207264

JX4040F30 0.3 79 (7,3) Fiberglass Male 30 (0.76) 3049975

JX4040F50 0.3 62 (5.8) Fiberglass Male 50 (1.27) 3049974

JX8040F30 0.3 340 (31,6) Fiberglass Female 30 (0.76) 1207283

JX8040F50 0.3 269 (25,0) Fiberglass Female 50 (1.27) 1207284

To protect your UF membranes, use ZCore (20micron) for the 50mil spacer elements.

Page 16: membrane elements - industrial applications · Membrane flux (water permeability constant) is designated by a letter in position 2. Some membrane types, such A-Series and D-Series,

Page 16 IndustrialCatalog.docx

acid recovery DURACID NF is a propriety nanofiltration membrane developed by SUEZ and is designed to operate continuously

under extreme acid conditions where pH is at or below zero. These elements are engineered to withstand high

pressure and operating temperatures up to 75˚C in order to enable metal concentration in sulphuric and

phosphoric acid solutions up to 20-25%. Among other applications, DURACID NF Elements are used for acid

purification and metals concentration in low pH streams. They feature patented feed spacers, polysulfone parts

and a fiberglass outer wrap. All materials of construction are low pH tolerant.

Duracid Elements

Model Average flow

gpd (m3/day)1,2

Average MgSO4

rejection1,2

Active Area ft² (m²) Outer wrap Connection Spacer mil (mm) Part Number

DURACID NF2540F30 560 (2.1) 98% 28 (2,6) Fiberglass Male 30 (0.76) 1231058

DURACID NF4040F35 525 (2.0) 98% 77 (7.1) Fiberglass Male 35 (0.89) 3050564

DURACID NF8040F35 2,050 (2.8) 98% 333 (30.9) Fiberglass Female 35 (0.89) 1231068 1 Average permeate flow and salt rejection measured on pre-conditioned elements after 24 hours operation. Individual flow rate may vary ±25% 2 Testing conditions: 2,000ppm MgSO4 solution at 110psi (760kPa) operating pressure, 77 °F (25°C), 15 % recovery. 3 Testing conditions: 3% glucose solution at 440psi (3034kPa) operating pressure, 77⁰F (25⁰C), 15% recovery.

“heavy duty” industrial applications The Industrial RO Series elements feature membrane chemistries and materials of construction compatible

with end of pipe wastewater applications such as Secondary and Tertiary Effluent, where significant reduction

of COD as well as reduction of total dissolved solids is desired. Industrial RO F50 elements are specially

designed for comparatively higher suspended solids levels.

Industrial

Model Average flow

gpd (m3/day)

Average NaCl

rejection

Active Area ft² (m²) Outer wrap Connection Spacer mil (mm) Part Number

INDUSTRIAL RO3 4040F35 1,900 (7.2) 99% 77 (7.1) Fiberglass Male 30 (0.76) 3050577

INDUSTRIAL RO3 4040F50 1,450 (5.5) 99% 61 (5.7) Fiberglass Male 50 (1.27)) 3049999

INDUSTRIAL RO3 8040F35 7,800 (29.5) 99% 333(30.9) Fiberglass Female 30 (0.76) 1207451

INDUSTRIAL RO3 8040F50 6,500 (24.6) 99% 269 (25.0) Fiberglass Female 50 (1.27) 1207450

Page 17: membrane elements - industrial applications · Membrane flux (water permeability constant) is designated by a letter in position 2. Some membrane types, such A-Series and D-Series,

IndustrialCatalog.docx Page 17

high temperature sanitization and operation The membranes in this category are specifically designed to maximize the benefits of hot water sanitization for

industries relying on chemical-free sanitization for product quality and/or industry compliance standards.

The Duratherm HWS elements are suitable for separation systems purifying water at temperatures up to 50°C

(122°F) in low cross-flow environment and no suspended solids.

Duratherm HWS Elements

Model Average flow

gpd (m3/day)

Average

NaCl/MgSO4

rejection /MWCO

Active Area

ft² (m²)

Connection Spacer mil

(mm)

Maximum Temperature (⁰C) Part Number

Operation Sanitization

DURATHERM HWS RO2540HR1,4 620 (2.3) 99.5% 24 (2.2) Male 30 (0.76) 50 90 1263600

DURATHERM HWS RO4040HR1,4 2,250 (8.5) 99.5% 89 (8.3) Male 30 (0.76) 50 90 1263435

DURATHERM HWS RO8040HR1,4 9,000 (34.1) 99.5% 374 (34.8) Female 30 (0.76) 50 90 1263599

DURATHERM HWS RO25402,4 760 (2.9) 99% 24 (2.2) Male 30 (0.76) 50 90 1228430

DURATHERM HWS RO40402,4 2,250 (8.5) 99% 89 (8.3) Male 30 (0.76) 50 90 1228459

DURATHERM HWS RO80402,4 9,000 (34.1) 99% 374 (34.8) Female 30 (0.76) 50 90 1228481

DURATHERM HWS SG80402 8,600 (32.6) 98.5% 374 (34.8) Female 30 (0.76) 50 90 1207613

DURATHERM HWS NF40403,4 2,400 (9.1) 99.5% 89 (8.3) Male 30 (0.76) 50 90 1263437

DURATHERM HWS NF80403,4 10,200 (38.6) 99.5% 374 (34.8) Female 30 (0.76) 50 90 1262377

DURATHERM HWS UF8040 - 10,000 Da 348 (32.3) Female 30 (0.76) 50 90 1263602

1Testing conditions: 2,000ppm NaCl solution at 225psig (1,550kPa) operating pressure, 77°F, pH7.5 and 15% recovery before any hot water

sanitization. 2 Testing conditions: 500ppm NaCl solution at 115psig (790kPa) operating pressure, 77°F, pH7.5 and 15% recovery before any hot water

sanitization. 3 Testing conditions: 2,000ppm MgSO4 solution at 110psig (760kPa) operating pressure, 77°F, pH7.5 and 15% recovery before any hot

water sanitization. 4 Average salt rejection after 24 hours operation. Individual flow rate may vary +25%/-15%. Final permeate flow rate is subject to

variations in the heat treatments. In most cases, the permeate flow rate after heat treatments will stabilize at 30-50 percent below the

nominal flowrate before heat treatment. For a conservative design, consider a permeate flow reduction of 50%.

To protect your UF membranes, use ROSave.Z for 30mil spacer elements and ZCore (20micron) for the 50mil spacer elements

The Duratherm STD are suitable for separation systems purifying hot water streams at temperatures up to

70°C (158°F) in low crossflow environment and no suspended solids. Condensate recycling is a typical

application where these elements are used.

Duratherm STD Elements

Model Average

flow gpd

(m3/day)

Average

NaCl/MgSO4

rejection /MWCO)

Active

Area

ft² (m²)

Connection Spacer mil

(mm)

Maximum Temperature (⁰C) Part Number

Operation Sanitization

DURATHERM STD RO40401,2, 2,250 (8.5) 99.5 89 (8.3) Female 30 (0.76) 70 90 1228197

DURATHERM STD RO80401,2, 9,000

(34.1)

99.5 374 (34.8) Female 30 (0.76) 70 90 1228225

DURATHERM STD UF8040HR4 N/A 10,000Da 348 (32.3) Female 30 (0.76) 70 90 1207315

1 Testing conditions: 2,000ppm NaCl solution at 225psig (1,550kPa) operating pressure, 77°F, pH7.5 and 15% recovery before any hot

water sanitization. 2 Average salt rejection after 24 hours operation. Individual flow rate may vary +25%/-15%. Final permeate flow rate is subject to variations

in the heat treatments. In most cases, the permeate flow rate after heat treatments will stabilize at 30-50 percent below the nominal

flowrate before heat treatment. For a conservative design, consider a permeate flow reduction of 50%.

N/A – not available

To protect your UF membranes, use ROSave.Z for 30mil spacer elements and ZCore (20micron) for the 50mil spacer elements

Page 18: membrane elements - industrial applications · Membrane flux (water permeability constant) is designated by a letter in position 2. Some membrane types, such A-Series and D-Series,

Page 18 IndustrialCatalog.docx

The DURATHERM EXL elements are also suitable for separation systems (either water or process streams) at

temperatures up to 70°C (158°F). All element constructions include polysulfone ATD & central tube and a

patented DURASAN cage outer wrap. These elements can be used to concentrate high temperature process

streams. Typical applications include concentration, purification and fractionation of high dissolved solid

streams that would be too viscous to enable membrane process at colder temperatures.

Duratherm EXL Elements

Model Average

flow gpd

(m3/day)

Average

NaCl/MgSO4

rejection* /MWCO

Active

Area

ft² (m²)

Connection Spacer mil

(mm)

Maximum Temperature (⁰C) Part Number

Operation Sanitization

DURATHERM EXL RO2540HR1,3 400 (1.5) 99% 18 (1.7) Male 50 (1.27) 70 90 1228306

DURATHERM EXL RO8040HR1,3 6,500 (24.6) 99% 275 (25.5) Female 50 (1.27) 70 90 1228840

DURATHERM EXL NF2540HR1,3 350 (1.3) 99.5% 18 (1.7) Male 50 (1.27) 70 90 1206922

DURATHERM EXL NF4040HR1,3 1,350 (5.1) 99.5% 65 (6.0) Female 50 (1.27) 70 90 1206950

DURATHERM EXL NF40402,3 1,750 (6.6) 99.5% 65 (6.0 Female 50 (1.27) 70 90 1207032

DURATHERM EXL NF8040HR2,3 6,400 (24.2) 99.5% 275 (25.5) Female 50 (1.27) 70 90 1206982

DURATHERM EXL NF80402,3 7,800 (29.5) 99.5% 275 (25.5) Female 50 (1.27) 70 90 1207045

DURATHERM EXL UF280403 N/A 2,500 275 (25.5) Female 50 (1.27) 70 90 3002290

*Salt rejection rate measured at 25°C 1Testing conditions: 2,000ppm NaCl solution at 420psig (1,550kPa) operating pressure, 77°F, pH7.5 and 15% recovery before any hot water

sanitization. 2 Testing conditions: 2,000ppm MgSO4 solution at 110psig (760kPa) operating pressure, 77°F, pH7.5 and 15% recovery before any hot water

sanitization. 3 Average salt rejection after 24 hours operation. Individual flow rate may vary +25%/-15%. Final permeate flow rate is subject to

variations in the heat treatments. In most cases, the permeate flow rate after heat treatments will stabilize at 30-50 percent below the

nominal flowrate before heat treatment. For a conservative design, consider a permeate flow reduction of 50%.

To protect your membranes, use and ZCore (20micron) for the 50mil spacer elements with high temperature exposure.

water reclamation applications Duraslick* is a series of membrane elements engineered for use with fouling-prone brackish water

applications and industrial effluent treatment before reuse or discharge. Duraslick is designed to utilize an

innovative three-layer membrane, of which a proprietary middle layer creates extreme smoothness, and

neutral charge.

Duraslick Elements

Model Average flow gpd

(m3/day)

Average NaCl/

MgSO4 rejection

Active Area

ft² (m²)

Outer wrap Connection Spacer mil (mm) Part Number

DURASLICK RO2540,1,2 550 (2.1) 98.5% 28 (2,6) Fiberglass Male 30 (0.76) 1231055

DURASLICK RO40401,2 1,900 (7.2) 98.5% 85 (7.9) Fiberglass Male 30 (0.76) 1231048

DURASLICK RO80401,2 7,700 (29.1) 98.5% 369 (34.3) Fiberglass Female 30 (0.76) 1231014

DURASLICK NF2540,1,3 600 (2.2) 98% 28 (2,6) Fiberglass Male 30 (0.76) 1234385

DURASLICK NF40401,3 2,400 (9.1) 98% 85 (7.9) Fiberglass Male 30 (0.76) 1234307

DURASLICK NF80401,3 8,600 (32.6) 98% 369 (34.3) Fiberglass Female 30 (0.76) 1234182

1Average salt rejection after 24 hours operation. Individual flow rate may vary +25%/-25%. 2Testing conditions: 2,000ppm NaCl solution at 225psig (1,551 kPa) operating pressure, 77°F (25°C), pH7.5 and 15% recovery. 3Testing conditions: 2,000ppm MgSO4 solution at 110psi (760kPa) operating pressure, 77°F (25°C), pH7.5 and 15% recovery.

To protect your UF membranes, use ROSave.Z for 30mil spacer elements and ZCore (20micron) for the 50mil spacer elements

Page 19: membrane elements - industrial applications · Membrane flux (water permeability constant) is designated by a letter in position 2. Some membrane types, such A-Series and D-Series,

IndustrialCatalog.docx Page 19

spare parts

Page 20: membrane elements - industrial applications · Membrane flux (water permeability constant) is designated by a letter in position 2. Some membrane types, such A-Series and D-Series,

Page 20 IndustrialCatalog.docx

Some membrane elements are not supplied with ATD or an IC kit. Refer to “Product Selection Guide” section

to select your element and order these pieces separately if necessary.

glossary

Interconnector (IC) - The interconnector is used to connect

the permeate tubes of adjacent elements.

Interconnectors for female/male elements

Product End Adaptor (PEA) - The product end adaptor is

used to connect the permeate tube of the element to the

permeate port of the pressure vessel end cap assembly.

This part is supplied by housing manufacturer. Please

contact your SUEZ representative for further information.

Product End Adaptors for female/male elements

Spacer Tube - The spacer tube is used as a permeate tube

extension to fill space between the upstream element(s) and

the permeate port of the pressure vessel end cap assembly.

It is often utilized in retrofit situations with a product end

adaptor and/or a closed end plug. The spacer tube helps

prevent shifting of the elements in the pressure vessel in

conjunction with a thrust ring provided by the system

manufacturer.

Anti-Telescoping Device (ATD) - The anti-telescoping disc

is connected to the element to provide support to the ends

of the element preventing displacement of the outer portion

relative to the permeate tube (telescoping).

Brine Seal - The brine seal, most often located at the feed

end of the element, seals the outer-most part of the element

with the inside of the pressure vessel wall and directs the

feed solution to the inside of the element. The brine seal

minimizes passage of the feed solution around the outside

of the element.

Dead End Plugs (DEP) - The dead end plug is used to seal

the open end of the permeate tube farthest from the

permeate removal end of the pressure vessel when

permeate removal is from only one end of the vessel. It is

used in retrofit situations where there is space between the

upstream element and the pressure vessel end cap.

Dead End Plug for female/male elements

Page 21: membrane elements - industrial applications · Membrane flux (water permeability constant) is designated by a letter in position 2. Some membrane types, such A-Series and D-Series,

IndustrialCatalog.docx Page 21

ordering parts

accessory kits

One accessory IC kit is included with each standard membrane element. The accessory kit for fiberglass and tape

elements includes one interconnector and two sets of O-rings. The kit for the cage elements includes one

interconnector, two flat anti-telescoping discs and two sets of O-rings.

Following kits (DEP or IC) available as a separate item for service maintenance change-outs include:

- one interconnector IC / dead end plug DEP.

- o-rings, number being specified in “o-ring part #” column between brackets.

All elements are supplied with ATDs. Only fiberglass and tape wrap elements are supplied with brine seals. The

below parts are for ordering spares.

Interconnector Kits

Diameter Kit # IC kit Part # IC Part # O-ring Part #

Permeate Tube: Stinger style male elements (0.75 in)

2.5in 6 1206581 CELCON/BUNA-N 1205503 CELCON (8) 3052771 BUNA-N

2.5in/4in 35 1206609 PSO/Viton 1205381 PSO (8) 1205600 Viton

2.5in/4in 113 1224608 PSO/EPDM 1205381 PSO (8) 3052372 EPDM

4in 70 1226284 CELCON/EPDM 1205503 CELCON (8) 3052372 EPDM

Permeate Tube: Flush cut female elements

4in 2 1206577 PSO/BUNA-N 1205423 PSO (8) 3052189 BUNA-N

8in 24 1206598 NORYL/EPDM 1205451 NORYL (6) 1118747 EPDM

8in 122 1229989 NORYL/BUNA 1205451 NORYL (6) 3055547 BUNA-N

8in 67 1206624 PSO/EPDM* 1205428 PSO (6) 1227634 EPDM

8in 1231007 316SS/EPDM** 1231006 316SS (6) 1118747 EPDM

8in 127 1231077 PSO/Viton 1205428 PSO (6) 3052257 Viton

8in 1200883 316SS/EPDM 1200195 316SS (6) 1118747 EPDM

8in solid 1200196 316SS Electro polish 1156517 316SS

*600psi

**1200psi

Dead End Plug Kits

Diameter Kit # DEP kit Part # DEP Part # O-ring Part #

Permeate Tube: Stinger style male elements (0.75in)

2.5in/4in 101 1206575 CELCON/BUNA-N 1205507 CELCON (4) 3052771 BUNA-N

4in 116 3052015 PSO/Viton 3052070 PSO (4) 1205660 Viton

4in 117 3052016 PSO/EPDM 3052070 PSO (4) 3052372 EPDM

Permeate Tube: Flush cut female elements

4in 87 1206534 PSO/BUNA 1205436 PSO (2) 3052189 BUNA-N

4in 17 (Millipore) 1206592 PVC/BUNA-N 1205468 PVC (4) 3052186 BUNA-N

8in 119 1229773 PSO/EPDM 1205439 PSO (2) 1205593 EPDM

Anti-Telescoping Device Kits

Diameter Kit # Outer wrap ATD Part #

2.5in Fiberglass, tape, cage (2) 1205379 PSO

4in Fiberglass, tape (2) 1117163 ABS 5 Vane

4in Net (2) 1117602 ABS 5 Vane

4in 4 & 149 Cage (2) 1205382 PSO Flat Disc

8in Fiberglass, Net (2) 3031386 ABS 16 Vane

8in Cage (2) 1205388 PSO 8 Vane

Page 22: membrane elements - industrial applications · Membrane flux (water permeability constant) is designated by a letter in position 2. Some membrane types, such A-Series and D-Series,

Page 22 IndustrialCatalog.docx

PEA Kits

Diameter Kit # Kit Part # PEA Part # O-ring Part # Membrane Element

Manufacturer

Housing Manufacturer / Housing Type

0.625-in female permeate tube

4in 50 1206614 (1) 1205391 PSO (4) 3052189 BUNA-N

(4) 1205580 BUNA-N

SUEZ SUEZ/Victaulic

4in 1160110 (2) 1160111 PVC (2) 1143426 EPDM SUEZ SUEZ/Flared

0.75-in male permeate tube

4in 90 1206539 (1)1205448 PSO (4) 3052189 BUNA-N SUEZ

4in 82 1206525 (1) 1205406 PSO (2) 1205580 BUNA-N

(2) 1205581 BUNA-N

Koch/Fluid Systems

4in 62 1206619 (1) 1205463 PVC (4) 1205581 BUNA-N SUEZ Pentair 4B

4in 1162524 (2) 1140413 PVC (4) 1151580 EPDM

(4) 1118748 EPDM

SUEZ SUEZ/Victaulic

4in 1158438 (2) PVC

Hydranautics

Hydranautics

4in 1159435 (1) 1158438 PVC (4) 1151580 EPDM( SUEZ SUEZ/Victaulic

4in 1162142 (2) 1162141 PVC (4) 1143426EPDM

(4) 1118748 EPDM

Trisep, TSA SUEZ/Victualic

4in 1159435 (1) 1158348 PVC (1) 1151580 EPDM SUEZ/Filmtec SUEZ/Flared

4in 1159437 (2) 1158438 PVC (2) 1151580 EPDM Hydranautics MSA SUEZ/Flared

4in 3051678 Protec (1) 50400003-1 PVC Protec Protec

0.75-in female permeate tube

4in 1162524 (2) 1140413 PVC (4) 1151580 EPDM

(4) 1118748 EPDM

SUEZ/Filmtec SUEZ/Victaulic

4in 1160112 (2) 1160113 PVC (2) 1118748 EPDM Trisep SUEZ/Flared

0.775-in female permeate tube

4in 1162851 (2) 1117167 PVC (8) 1118748 EPDM SUEZ SUEZ/Victaulic – Standard

4in 1163362 (2) 1118737 NORYL (8) 1118748 EPDM SUEZ SUEZ/Victaulic – High Purity

4in 1159436 (2) 1158347 PVC (2) 1118748 EPDM SUEZ SUEZ/Flared

0.830-in male permeate tube

4in 1162513 (2) 1162496 PVC (4) 1162468 EPDM

(2) 1162503 EPDM

Hydranautics SUEZ/Victaulic

1.125-in female permeate tube

8in 1239522 (1) 1223016 NORYL-

SOLID

(4) 1118747 EPDM SUEZ SUEZ/RC

8in 1231007 (1) 1231006 SS316 (4) 1118747 EPDM SUEZ SUEZ/RC

8in 1239474 (1) 1231004 SS316

SOLID

(4) 1118747 EPDM SUEZ SUEZ/RC

8in 1239496 (2) 1239475 PVC (4) 1118747 EPDM

(4) 1162525 EPDM

Koch/Fluid Systems SUEZ/RC

8in 1239491 (2) 1239490 PVC (2) 1158677 EPDM

(4) 1118747 EPDM

(3) 1159955 PVC spacer

Hydranautics SUEZ/RC

8in 1239489 (2) 1239488 PVC (4) 1162501 EPDM

(4) 1118747 EPDM

Trisep SUEZ/RC

8in 106 1227365 (1) 1205454 NORYL (4) 1118747 EPDM SUEZ Codeline

8in 1239489 (2) 1239488 PVC (4) 1162501 EPDM

(4) 1118747 EPDM

Trisep/Filmtec SUEZ/RC

8in 3015550 50161 SUEZ Codeline 80A-450

1.135-in female permeate tube

8in 1162504 (2) 1115808 PVC (8) 1118747 EPDM SUEZ SUEZ/Tri-Clamp

8in 1163363 (2) 1144885 PVC (4) 1118747 EPDM

(4) 1185024 EPDM

SUEZ/Desal SUEZ/Tri-Clamp

8in 1162521 (2) 1144919 PVC (8) 1118747 EPDM SUEZ/Filmtec SUEZ/Tri-Clamp

8in 1162522 (2) 1144886 PVC (4) 1118747 EPDM

(4) 1162525 EPDM

Koch/Fluid Systems SUEZ/Tri-Clamp

8in 1162523 (1) 1158676 PVC (1) 1158677 EPDM

(2) 1118747 EPDM

(3) 1159955 PVC spacer

Hydranautics SUEZ/Tri-Clamp

8in 1162514 (2) 1162497 PVC (4) 1124149 EPDM

(4) 1162501 EPDM

Nitto-Denko SUEZ/Tri-Clamp

8in 1162509 (2) 1162493 PVC (2) 1162501 EPDM

(4) 1185039 EPDM

Trisep SUEZ/Tri-Clamp

8in 105 122734 (1) 1205444 PSO (4) 1118747 EPDM SUEZ SUEZ/Tri-Clamp

Page 23: membrane elements - industrial applications · Membrane flux (water permeability constant) is designated by a letter in position 2. Some membrane types, such A-Series and D-Series,

IndustrialCatalog.docx Page 23

PEA Kits

Diameter Kit # Kit Part # PEA Part # O-ring Part # Membrane Element

Manufacturer

Housing Manufacturer / Housing Type

1.5-in female permeate tube

8in 3012625 5080049 Protec

3-inch Ports

8in 1204557 (2) 1204565 PVC (8) 1118747 EPDM SUEZ SUEZ

8in 1204558 (2) 1204566 PVC (8) 1118747 EPDM SUEZ SUEZ

Spacer Tubes (40in Length)

Diameter Part # Description Dimensions (in)

0.75-in male permeate tube

4in 1155194 TUBE, PERM, PVC, BLANK 0.83 x 40

1.125-in female permeate tube

8in 1221315 SPACER TUBE NORYL 1.125 x 1.125 x 40

8in 1227836 SPACER TUBE PSO 1.125 x 1.125 x 40

1.139-in female permeate tube

8in 1148066 PVC 1.139 x 1.139 x 40

8in 1118744 NORYL 1.139 x 1.139 x 40

4” wave cyber parts

Dwg Ref # Part # Quantity Description

1 3031359 1 SEAL, PORT, 300, WAVE, EPDM 512

2 3031390 1 PIN, SIDE PORT, ANIT-ROTATE, SS304

3 3031391 1 SIDE PORT, SA – 312, SS316L

4 3031392 1 RING, RETAINING, A580, SS316

5 3031393 1 RING, RETAINING, SIDE PORT, A580, SS316

6 3031394 2 BAFFLE, A580, SS304

7 3031395 1 ADPTR, PORT, PERMEATE, ABS

8 3031396 1 SEAL, HEAD, EPDM 512

9 3031397 1 SEAL, MVP, EPDM 512

10 3032878 1 PORT, PERMEATE, 4.0, 300PSI, PP

8” wave cyber parts

Dwg Ref # Part # Quantity Description

20 3041838 2 RING, EMBEDDED, PERMEATE, 450, WAVE

19 3041837 8 O-RING, SIDE PORT, 450, WAVE

18 3041836 4 RING, RETAINING, SIDE PORT, 2.0, EXT, WAVE

17 3041835 2 PLATE, BEARING, ALUMINUM, 6061-T651

16 3041834 4 ADPTR, SIDE PORT, 450, 2.0, WAVE, COD

15 3035616 1 PLUG, UNION, H-OPTION, ABS, 1.0, WAVE

14 3035615 1 ADPTR, VIC, V-OPTION, PVC, 1.00, WAVE

13 3035613 2 O-RING, H-OPTION, EPDM, 33MM X 0.31MM, WAVE

12 3035612 2 UNION, NUT, H-OPTION, PVC, C1, 50-11, WAVE

11 3035611 2 PLATE, PERM, H-OPTION, PP-FG,C1, 50-11, WAVE

10 3022445 4 RING, RETAINING, SIDE PORT, 2.0, WAVE

9 3021976 2 RING, LOCKING, 316SS, WAVE

8 3021975 2 LTD, CONE, WAVE

7 3021974 2 RING, RETAINING, PERMEATE, WAVE

6 3021973 4 O-RING, PERMEATE, ADPTR, WAVE

5 3012624 4 SEAL, SIDE PORT, 450, 2.0, WAVE

4 3012623 4 SEAL, SIDE PORT, CURVE, 450, 2.0, WAVE

3 3012621 2 SEAL, PERMEATE PORT, 450, WAVE

2 3012611 2 ADPTR, ENDCAP, 450, WAVE

1 3012610 2 SEAL, HEAD, 450, WAVE

Page 24: membrane elements - industrial applications · Membrane flux (water permeability constant) is designated by a letter in position 2. Some membrane types, such A-Series and D-Series,

Page 24 IndustrialCatalog.docx

Accessories

Diameter Part # Type of Accessory

2.0in 1151580 O-Ring, EPDM, 116,70DUR End Cap Permeate Connection

2.0in 1159957 O-Ring EPDM, 342,70DUR End Cap Housing Connection

2.5in 1205611 EPDM Brine Seal

2.5in 1151580 O-Ring EPDM, 116,70DUR End Cap Permeate Connection

2.5in 1151581O-ring EPDM, 227 End Cap Housing Connection

4in 1115762 BUNA-N

1116160 EPDM

Concentrate Seal

Concentrate Seal

4in 1146970 Victaulic EPDM Gasket

4in 1111624 Victaulic Nitrile Gasket

8in 1118751 EPDM Concentrate Seal

8in 1156580 O-Ring, BUNA-N, 367,60DUR End Cap (1 per end cap)

8in 1151287 LTC, Viton, 1.5 Gasket, 3A, Tri-clamp

8in 1151289 LTC, Viton, 2.0 Gasket, 3A, Tri-clamp

8in 1151290 LTC, Viton, 3.0 Gasket, 3A, Tri-clamp

8in 1153147 LTC, EPDM, 1.5 Gasket, 3A, Tri-clamp

8in 1155327 LTC, EPDM, 2.0 Gasket, 3A, Tri-clamp

8in 1163023 LTC, EPDM, 3.0 Gasket, 3A, Tri-clamp

8.3in 1118749 BUNA-N Concentrate Seal


Recommended