Storage capacity : 12,000 measurement pointsWith or without 1-line display
Class 100temperature and humidity dataloggers
Class 200temperature and humidity dataloggers
Temperature - KT 100 1 internal sensor - with or without input for external probeExternal probes temperature, current, voltageMeasuring ranges -40°C to +70°C and -40°C to +120°C (external)Resolution 0.1°CIP 40 or IP 67 housing protection
1 internal sensor - 4 inputs for external probesExternal probes temperature, current, voltageMeasuring ranges from -40°C to +70°C and from -40°C to +120°C (external)Resolution 0.1°CIP 40 or IP 67 housing protection
3 internal sensors - 2 inputs for external probesExternal probes temperature, current, voltage
Measuring ranges from 5 to 95%RH, -20°C to +70°C or -20°C to +80°C,-40°C to 120°C (external) and 0 to 10000 lux
Resolution 0.1%RH, 0.1°C and 1 luxIP 40 or IP 67 housing protection
Temperature / Humidity / Light - KH 200
Temperature - KT 200
Storage capacity : 16,000 measurement pointsWith or without 2-line display
3 internal sensorsParameters humidity, temperature and light
Measuring ranges from 5 to 95%RH, from -20°C to +70°C, from 0 to 10000 luxResolution 0.1%RH, 0.1°C and 1 lux
IP 40 housing protection
Temperature / Humidity / Light - KH 100
Data collector(storage capacity of500,000 values).
Portable printer fordata collector
PT100 andthermocoupletemperatureprobes
Ammeterclamps from
0-20 A to 0-600 A
Temperature •Humidity •
Light •Voltage •
Current •
Temperature •Humidity •
Light •Voltage •
Current •
KILOG CFRsoftware in accordancewith 21 CFR part 11standards
2
3
PT100 remote probe2 inputs for external probesExternal probes temperature, current, voltageMeasuring range from -100 to +400°CResolution 0.1°CIP 67 housing protectionSuitable for prevention of Legionella risks in water systems
PT100 Temperature - KTR 300
Thermocoupletemperature - KTT 300
Thermocouple K, J, or T remote probe2 inputs for external probes
Measuring rangesfrom -200°C to +400°C T
-100°C to +750°C J-200°C to +1000°C K
Resolution 0.1°CIP 43 housing protection
Ambient and remote probe PT100 and capacitiveWith 2 or without internal sensors
1 or 2 inputs for external probesDew point temperature
External probes temperature, current, voltageMeasuring ranges 0 to 100%RH, -20°C to +70°C or
-20°C to +120°C or -40°C to +180°C,and -100 to +400°C (external)
Resolution 0.1%RH, 0.1°CIP 54/ IP 67 housing protection
PT100 Temperature /Humidity - KTH 300
Probesand accessories
KISTOCKdata processingsoftware
Ideal for food produce, archive material or any goodssensitive to environmental conditions...4 specific ranges
to meet all your applications.
Hygrometryprobes -40 to
+180°C
Class 300temperature and humidity
dataloggersStorage capacity : 100,000 measurement points
With 2-line display
0-10 V voltage and 0/4-20 mAcurrent input cables
Wall-mountingbracket with anti-theft system andmagnetic fixing
1- Easy configuration.
2- Fast data download : 1,000values/second via USB 2.0 cable.
3- Data processing or data acquisition in real time.
5
From 0 to 100%RH and from -40 to +180°C.Polycarbonate or stainless steel probe, standard or
remote (lengths available 100 mm, 150 mm or 300 mm)with 2m cable.
PTFE or stainless steel sintered tip, protective plastichead, stainless steel perforated head.Functions : relative and absolute humidity, wet and dry
temperature, dew point, enthalpy.
Temperature / Humidity - TH 200
Class 200for HVAC and process
Remote probe
Common features Configuration via keypad, remote control and software
Advanced calculation functions Simultaneous display of 2 parameters 2 Configurable relays with visual alarm 18-30 Vdc or 24 Vac/Vdc power supply 2 4-20 mA or 0-10 V analogue outputs 1 RS 232 output With or without display ABS housing
Connected to DEBIMO measuring blades, and with SQR 2function, CP200 can control air velocity and airflow in a duct,
from the differential pressure.
Airflow - Air Velocity - SQR 2 option
Pressure - CP 200From 0/+100 Pa to -2000/+2000 mbar.
Manual auto-zero.Barbed or compression fittings.
Functions : pressure, air velocity, airflow,integration of pressure measurement,
measurement correction factor,temperature compensation.
Air Velocity - CTV 200
From 0-1 m/s to 0-20 m/s and from 0 to +50°C.Stainless steel remote probe (150 or 300 mm long.)Functions : air velocity, airflow, measurement
correction factor.
Pressure •Temperature •
Humidity •Velocity •
Airflow •
Pressure •Temperature •
Humidity •Velocity •
Airflow •
PressureFrom 0/+1000 Pa to
-5000/+10 000 Paand -1000/+2000 mbar.
TemperatureFrom 0 to +50°C (ambient)From -20 to +80°C (duct
mount or airtight probe)Depends on Pt100 probe
(on terminal block)
Air VelocityFrom 0 to 30 m/sFrom 0 to +50°C
Duct mount orremote probe
(150 or 300 mm long.)
Temperature / HumidityFrom 0 to 100%RHFrom -20 to +80°C
Probe type : standard, remote, duct mount or ambient
Humidity
From 0 to 100%RH
Class 50 and Class 100for HVACCommon features
Air tight model Terminal block model
Ambient model model Duct mount model
Duct mount model
Monostatsfor HVAC
From 0 to +50°C (ambient)From -20 to +80°C (airtight)
Depends on Pt100 probe (on terminal block)
From 0 to100%RH, from 0 to+50°C (ambient) orfrom -20 to +80°C(duct mount orremote probe).
From -500/+1000 Pa to-1000/+2000 mbar.
Manostats - PST
Hygrostats - HSTThermostats - TST
Remote probe model
Duct mount model
Airtight model Ambient model
Common featuresConfiguration via DIP switch and software
18-30 Vdc or 24 Vac/Vdc power supplySPDT relay (Single Pole Double Throw)
With displayABS housing
Configuration via DIP switch and software18-30 Vdc or 24 Vac/Vdc power supply
4-20 mA or 0-10 V analogue outputsWith or without displayABS housing
4
6
Temperature / HumidityTH 300
PressureCPA 300
From 0/+10 Pa to -10 000/+10 000 PaSelf-calibration liBarbed connectionsFunctions : pressure, air velocity, airflow, integration of pressure measurement, measurement correction factor, automatic or manual temperature compensation (thermocouple K input).
From 0-100%RH and -40 to +180°CFunctions : relative and absolute humidity, wet and dry temperature, dew point, enthalpy.Polycarbonate or stainlees steel probe, standard or remote probe(lengths available 100 mm, 150 mm or 300 mm) with 2m cable.
Stainless steel or PTFE sintered tip, protectiveplastic head, stainless steel perforated head.
Class 300for HVAC and process
ABS model
Temperature / HumidityTHA 300
Common features
Standard probe model
Configuration via keypad, remote control and softwareInterchangeable probesAdvanced calculation functions
Display of 4 parameters simultaneously2 or 4 configurable relays with visual alarm
24 Vac/Vdc or 230/115 Vac power supply2 4-20 mA or 0-10 V analogue outputs
1 RS 232 outputRS 232 connection and RS 485 Modbus network
With or without digital displayStainless steel or ABS housing
Connected to DEBIMO measuring blades, and with SQR 2function, CP200 can control air velocity and airflow in a
duct, from the differential pressure.
Airflow - Air Velocity - SQR 2 option
PressureCP 300
Pressure •Temperature •
Humidity •Velocity •
Airflow •
Pressure •Temperature •
Humidity •Velocity •
Airflow •
7
Class 300flush-mount
Designed to measure and monitor cleanrooms,this model is perfect for flush-mounting in a
wall or a panel.
From -100/+100 Pa, -500/+500 Pa, -1000/+1000 Pa Front made of brushed stainless steel or white lacquered
Outputs : 4-20 mA or 0-10V and RS 232 Configuration via software or infrared remote control
Power supply : 24 Vac/Vdc
Flush-mount pressure sensor - CPE 300
Face calibration : innovative system whichallows you to connect your transmitter (wheninstalled) to a dynamic pressure calibration
bench.
Via RS232 connection, CPE300 can displayalternatively (in addition to the pressure) other
parameters such as temperature and humidity froma TH200 transmitter for example.
Modbus network (RS 485system)
Pt 100, Pt 1000 Thermocouple K, J, T
Head type : threaded, with metallic protection, DIN B, plastic, standards...
Type of probe : contact, food, soft (to be glued), penetration, insulated sheath...
Cables : PVC, Teflon, sheathed, glass silk...
Head holder andoutput on cable
Temperatureprobes
Via current or voltage input cable,ATT300 display can be connectedto any type of transmitter :
pressure, humidity, temperature,airflow, air velocity...
Large display - ATT 300
Common featuresRS 232 communication and RS 485
Modbus network24 Vac/Vdc power supply
Pre-programmed measurement units
Can display up to 3 parameters(example : humidity, temperatureand pressure). Can be installedflush-mounted or wall-mounted.
Multi-channelflush-mount display - ATE 300
DisplaysRegulators
Mounting accessories :clamps, sliding
connections, spikes...
8
5 measuring ranges available between 0 ±1000 Pa and 2 barManual zero and autozero, or self-calibrationAir velocity and airflow with Pitot tube or Debimo blades2 thermocouple K channels from -200 to +1300°CUp to 8,000 measurement points, output for printerand PC connection
Vane anemometer from 0.20 to 35 m/s, -20 to +80°CHotwire anemometer from 0.00 to 30 m/s, -20 to +80°CAirflow function (in duct or with cones)2 Pt100 channels from -100 to +400 °CUp to 8,000 measurement points, output for printerand PC connection
MicromanometersClass 100/200 MP
AnemometersClass 100/200 LV and VT
Range from 60 to 50,000 RPM and 4 to 2500 m/minOptical or contact probe
Relative humidity from 5 to 95%RH and from 3 to 98%RHAmbient, wet and dry temperature from -20 to +80°CAbsolute humidity, dew point, surface and ambient2 Pt100 channels from -100 to +400°CUp to 8,000 measurement points, output for printerand PC connection
TachometerClass 100 CT
HygrometersClass 100/200 HD
Pressure •Temperature •
Humidity •Velocity •
Airflow •Tachometer •
Pressure •Temperature •
Humidity •Velocity •
Airflow •Tachometry •
MultifunctionsClass 300 AMI and VT
Common featuresEvolutionary, these instruments can measure several parameters
simultaneously. Their SMART PRO probes are automaticallyidentified by the instrument and are interchangeable.
Accessoriesfor portable instruments
SMART PRO PROBESDedicaced to Class 200/300 portable instruments, these
probes are interchangeable and are automatically reco-gnized by the instruments. These probes come withadjustment certificate.
Class 300 AMIMicromanometer from 0 to ±1000 Pa or from 0 to ±1000 mmH2O
Vane anemometer from 0.20 to 35 m/s, -20 to +80°CHotwire anemometer 0.00 to 30 m/s, -20 to +80°C
Hygrometer from 3 to 98%RH, -20 to +80°C2-channel Pt100 thermometer from -100 to +400°C
2-channel thermocouple K from -200 to +1300°CTachometer from 60 to 50,000 RPM and from 4 to 2500 m/minAir velocity and airflow with Pitot tube and with Debimo blades
from 2 to 40 m/s or 4 to 100 m/sUp to 8,000 measurement points, output for printer
and PC connection
Class 300 VTVane anemometer from 0.20 to 35 m/s, -20 to +80°CHotwire anemometer from 0.00 to 30 m/s, -20 to +80°CHygrometer from 3 to 98%RH, -20 to +80°C
2-channel Pt100 thermometer from -100 to +400°C2-channel thermocouple K from -200 to +1300°CTachometer from 60 to 50,000 RPM and from 4 to 2500 m/minUp to 8,000 measurement points, output for printerand PC connection
Thermocouple K temperature probesPitot tubes with or without temperature compensationPrinterData processing softwareProtective cover and protection hands-free holderAirflow conesDebimo blades...
Vane probes ø 100, 70 and 16 mmHotwire probesTelescopic hotwire probesHygrometry probesOptical and contact tachometry probesAirflow conesPt100 temperature probes
9
10
From 85 to 4000 m3/h6 sizes of hoods
Supply and exhaust
FlowmeterDBM 700
From 10 to 1200 m3/h4 sizes available :
200 x 200 mm, 300 x 300 mm, 450 x 450 mm, 550 x 100 mm
Installed on hotwire and vane anemometers, theymeasure airflow directly on vent grilles.
Airflow conesfor portable anemometers
20 sizes from 100 to 3000 mmNPL type, as per AFNOR standard
316 L stainless steel
Pitot tubes
Pitot tubesand DEBIMO measuring blades
Temperature •Velocity •
Airflow •
Temperature •Velocity •
Airflow •
From -200 to +1300°C2 thermocouple K and 2 Pt100 channels
Storage of values, interface for printer and PC connection
Class 200Thermometers
ThermometersPortables
Airflow cone for vaneprobe diam. 100 mm
anemometer.
With or without temperaturecompensation
Lengths available from 100to 3000 mmFrom 3 to 100 m/s
Debimo blades
Thermocouple K (from -200 to +1300°C) orPT100 (from -100 to +400°C)1 and 2 channelsSupplied with or without probe
Class 100Thermometers
DBM 700 is the key tool for balancing : itallows you to check airflow on any type of
grilles and onlarge air diffusers.
From the dynamic pressure measured in a duct,Pitot tubes and DEBIMO allow you to calculateair velocity and airflow.
A wide range of accessories is available to fit any installation withproper connections.
Liquid for manometersTube, junctions
Pressure connections, wall-crossing connection
Manometersliquid column
Accessoriesfor manometers
Pressure •Velocity •
Airflow •
Pressure •Velocity •
Airflow •
Allow you to read apressure measurement
and to activate a relay whensetpoint is passed.
From -500 to +500 Paand from -1000 to +1000 mbar.IP 65 protection
ECM - Mano-Pressostats
These models allow you to read a pres-sure measurement and to activate 1 or 2electrical relays, with a great accuracy andrepeatibility.
From 0-10 to 300 mmH2O230 Vac, 115 Vac and 24 Vac/Vdc power supply
Manual configuration of setpoint
Manostats
ManoPressostats
11
For very low differential pressure
Inclined manometers
From 0-5 to 0-100 mmH2OCentre 0 scale
Scale available in mmH2O, Pa, DaPa...
From 0-100 mmH2O to 0-2,6 barDirect reading or reading byaddition of columnsScale available in mmH2O, DaPa, mbar...
Vertical manometersFor high differential pressure with com-pact sizes.
Distributed by : IHSA - Ingenierííííííia en Higiene Seguridad y Ambiente 5411 49319133 [email protected]
Calibrations are carried outas per ISO 9001 standard pro-
cedures, and certificates areissued accordingly (as per
AFNOR standard).
Pressure
Temperature
Airflow
Tachometry
Air velocity
Humidity
KIMO designs, manufactures and sells instruments for measuring and monitoring airparameters in HVAC and industry. With 27-year experience, KIMO offers a large range of
products for your air / heating / refrigeration systems.
Non
-con
trac
tual
doc
umen
t -
We
rese
rve
the
right
to
mod
ify t
he c
hara
cter
istic
s of
our
pro
duct
s w
ithou
t pr
ior
notic
e.
C
ATA
LOG
UE
GE
NE
RA
LE
XP
OR
T-
V1
- A
ngla
is -
04/
06
Boulevard de Beaubourg BP 48EMERAINVILLE - F-77312 MARNE LA VALLEE
Tel + 33 (0)1 60 06 69 25Fax + 33 (0)1 60 06 69 29
With a new factory of 4,000 m2 and high-tech produc-tion units, our team of 140 people has one goal :
satisfy your needs.
Our new laboratories of 600 m2 are dedicated to cali-bration, adjusting and controls of our instruments;
they are equipped with modern calibration benchesregularly checked.