Click here to load reader
Date post: | 27-Nov-2014 |
Category: |
Documents |
Upload: | nirav-desai |
View: | 106 times |
Download: | 5 times |
Click here to load reader
I N D U S T R I E S
NIRMAL INDUSTRIES, MUMBAI - 80.
'
MESURA' B25 & B50 SERIESTWO-STAGE REGULATOR
REF. : MS/6/02/RO PAGE 1 OF 2
'These B25 & B50 Series two-stage
pressure regulators from MESURA'
France, are designed for use in a wide
range of both domestic and industrial
applications.
These regulators can be employed with
natural gas, LPG, butane, propane and
other gases.
These regulator can be installed both
outdoors and indoors with ensured
trouble-free operation in all mounting
positions.
Figure 1 : Typical Two-Stage Regulator
FEATURES
'
l Tradition of Excellence : Half a century's experience has made MESURA' the leader in domestic and industrial gas pressure regulators and their products are recognised worldwide.
Construction : Compact and light weight design with minimum number of moving parts.
Set Pressure : Different springs are available to cover wide range of outlet set pressure.
Two Stage Regulator :
l
l
l This ensures high precision outlet pressure control even at varying inlet pressure from 0.5 to 5 Barg.
In case of overpressure (outlet) : - Internal relief valve action.- Integrated slam shut valve action.
In case of underpressure (inlet) : - Integrated slam shut valve action.
In case of overflow : - Integrated slam shut valve action.
In case of 2nd stage diaphragm bursting : - Internal relief valve action.- Integrated slam shut valve action.
0Shut-off : - By turning start lever by 90 .
INTEGRATED SAFETY DEVICES
MESURA
R
TM
I N D U S T R I E S
NIRMAL INDUSTRIES, MUMBAI - 80.
REF. : MS/6/02/RO PAGE 2 OF 2
Represented by :
l ENQUIRY SPECIFICATIONS l
INLET PRESSURE
OUTLET PRESSURE
LINE/SIZE
SERVICE FLUID
FLOW MIN./MAX.
MAX. TEMP.
e. g. (B25-UO1R-EDX Or B50-UO2X-HXX)
Series
B
B
2
5
5
0
U
X
R
X
= Yes
= No
= Yes
= No
=At 150 mbarg
=At 275 mbarg
=No
O
O
X
1
2
X
1 2 3 4 5 6 7 8 9 10
X = No loose Spring.
A = 020-035 mbar,
C = 048-060 mbar,
E = 072-085 mbar,
G = 115-145 mbar,
B = 035-048 mbar,
D = 060-072 mbar,
F = 085-120 mbar,
H = 140-170 mbar,
Under Pressure
Shut-off
Over Pressure
Shut-off
Relief
Valve
Range Spring Fitted
In Regulator
Loose
Spring
Additional
Loose Spring
MODEL SPECIFICATION
4, NAHUR INDUSTRIAL ESTATE, L. B. S. MARG,
MULUND (W), MUMBAI - 400 080. INDIA.
PH. : 565 02 60 / 591 60 16
FAX : 91-22-568 27 71.
E-mail : [email protected]
WEBSITE : www.nirmalindustries.com
I N D U S T R I E S
Figure 2 : Gas Train
# : 5
40
0
4 6
9. E
-m
ail : g
iri_
ad
ho
me
@indiatim
es.com
Nominal Capacity : For B25 = 25 NM /Hr of Natural Gas & 30 Kg/Hr of LPG
3
3For B50 = 50 NM /Hr of Natural Gas & 60 Kg/Hr of LPG
Inlet Pressure : 0.5 to 5 Barg (7 to 70 psig)
Outlet Pressure : 20 to 170 mbar g (With different springs)
Over Pressure Shut-off : 150 or 275 mbar g
Inlet x Outlet Connection : 3/4" x 11/4" BSPT, Inlet & Outlet connection in line or
0at 90
SPECIFICATIONS
INLET
PR
ST
PG-1
OUTLET
IV
PG-2
MESURA
R
EN ISO 9001
Cer t i f i ca te : 041009509
TM
TM
OUTLET
Relief
Valve
Second Stage Regulation
Regulating Valve
First Stage
Regulation
Seat
U. P. S. O.
O. P. S. O.
INLET
'
MESURA' B25 & B50 SERIESTWO-STAGE REGULATOR