1 Innovus Power Proprietary- All Rights Reserved- March 2015 Microgrid Power Systems Lowering the LCOE of Hybrid Systems
Transcript
Page 1: Microgrid Power Systems -   · PDF fileMicrogrid Power Systems ... Control Unit Engine & Generator Power Converter Current - Utility Connection ... EPC’s “Standard” Solution

1 Innovus Power Proprietary- All Rights Reserved- March 2015

Microgrid Power Systems

Lowering the LCOE of Hybrid Systems

Page 2: Microgrid Power Systems -   · PDF fileMicrogrid Power Systems ... Control Unit Engine & Generator Power Converter Current - Utility Connection ... EPC’s “Standard” Solution

2 Innovus Power Proprietary- All Rights Reserved- March 2015

Maximizing renewable penetration

Grid stability trade offs Frequency control

Spinning reserve requirements

Storage solutions still expensive

System complexity

Curtailment

Fixed Speed GENSET challenges Minimum load (>30%)

Low efficiency at low loads

O&M Impact at low loads

LCOE Drivers and Challenges for Hybrid Systems

Innovus Power Proprietary- All Rights Reserved- March 2015

Fixed Speed Generators (FSG) How to adapt to challenges?

Diesel

Load

PV

Maximizing Renewable Penetration

Page 3: Microgrid Power Systems -   · PDF fileMicrogrid Power Systems ... Control Unit Engine & Generator Power Converter Current - Utility Connection ... EPC’s “Standard” Solution

3 Innovus Power Proprietary- All Rights Reserved- March 2015

Low efficiency at low loads

Fixed Speed Generator (FSG) Hybrid Challenges

200.0

300.0

400.0

500.0

600.0

0% 20% 40% 60% 80% 100%Average Load on Generator (% of Peak Power)

Fuel

co

nsu

mp

tio

n g

/kw

h

High Penetration Renewables drive GENSETS to operate at low loads

Major OEM Fixed Speed Generator (FSG)

50

55

60

65

70

0

100

200

300

400

500

0 2 4 6 8 10

Freq

uen

cy (

Hz)

RM

S V

olt

age

(V)

Time (seconds)

RMS Voltage, A-B

Frequency (Hz)

Frequency control with rapid load transients

Frequency Instability

Page 4: Microgrid Power Systems -   · PDF fileMicrogrid Power Systems ... Control Unit Engine & Generator Power Converter Current - Utility Connection ... EPC’s “Standard” Solution

4 Innovus Power Proprietary- All Rights Reserved- March 2015

RP

M

Time

Fixed Speed Generator

Innovus Variable Speed Generator

RP

M

Time

Peak Load

Average Load

1800 RPM

Generator Speed

Power Load

Generator speed mirrors the load

Generator speed fixed regardless of load

3 Phase AC

Piston Engine Generator

Engine controller

3 Phase AC Inverter

Active rectifier

Piston Engine

Permanent Magnet

Generator

Signal from Generator varies as electric load varies

Signal is converted to smooth AC output

DemandGenius Controller

Generator Speed

Power Load

Decouple Engine Speed from Frequency & Load

Innovus VSG Decouples Engine Speed from Frequency & Load

Page 5: Microgrid Power Systems -   · PDF fileMicrogrid Power Systems ... Control Unit Engine & Generator Power Converter Current - Utility Connection ... EPC’s “Standard” Solution

200.0

250.0

300.0

350.0

400.0

450.0

500.0

550.0

600.0

0% 20% 40% 60% 80% 100%

Operating Range for High Penetration Renewables

Average Load (% of Peak Power)

Fuel

co

nsu

mp

tio

n g

/kw

h

Innovus Variable Speed fuel consumption

Fixed Speed Generator From major OEM

Innovus VSG Delivers Higher Fuel Efficiency at All Loads

Innovus Power Proprietary- All Rights Reserved- 5

Innovus Variable Speed Generator efficiency

As Renewables reach higher penetration, VSG fuel burn remains low

Fixed Speed Generator (FSGs)

Page 6: Microgrid Power Systems -   · PDF fileMicrogrid Power Systems ... Control Unit Engine & Generator Power Converter Current - Utility Connection ... EPC’s “Standard” Solution

6 Innovus Power Proprietary- All Rights Reserved- March 2015

With stability controlled, Renewables can increase to 100% of Peak

Frequency variability

Fixed Speed Generator (FSG) based Power System

Innovus Variable Speed Generator (VSG) based Power System

Fixed frequency leads to stable Grids

50

52

54

56

58

60

62

64

66

68

70

0

50

100

150

200

250

300

350

400

450

500

0 2 4 6 8 10

Freq

uen

cy (

Hz)

RM

S V

olt

age

(V)

Time (s)

RMS Voltage, A-B

Frequency (Hz)

50

52

54

56

58

60

62

64

66

68

70

0

50

100

150

200

250

300

350

400

450

500

0 2 4 6 8 10Fr

equ

ency

(H

z)

RM

S V

olt

age

(V)

Time (s)

RMS Voltage, A-B

Frequency (Hz)

Page 7: Microgrid Power Systems -   · PDF fileMicrogrid Power Systems ... Control Unit Engine & Generator Power Converter Current - Utility Connection ... EPC’s “Standard” Solution

7 Innovus Power Proprietary- All Rights Reserved- March 2015

Innovus Microgrid Platform Solves the Cost Challenges

High Penetration Renewables Can Be Realized at Lower Cost

100% fossil fuel power 100% Renewable Power

Le

ve

lize

d C

ost

of

Ener

gy (

LCO

E)

Standard Solution LCOE

Increasing Renewables

Innovus Power System LCOE

Page 8: Microgrid Power Systems -   · PDF fileMicrogrid Power Systems ... Control Unit Engine & Generator Power Converter Current - Utility Connection ... EPC’s “Standard” Solution

8 Innovus Power Proprietary- All Rights Reserved- March 2015

400kW Hybrid System LCOE Case Study - Australia

Master Control Unit

Engine & Generator

Power Converter

Current - Utility Connection

Average load 400 kW

2,808,321 Annual kWh Usage

Large annual utility rate increases

AVG $0.32 kWh

EPC’s “Standard” Solution

FSG-Solar-Batteries-Converter

Non Solar Capex $1.6M

AVG LCOE $0.25 kWh

Innovus Solution

VSG-Solar-Energy Buffer

Non Solar Capex $ 1.4M

AVG LCOE $0.18 kWh

$394,000 per year savings • No Storage • High efficiency VSG at low load • Stable frequency control

Page 9: Microgrid Power Systems -   · PDF fileMicrogrid Power Systems ... Control Unit Engine & Generator Power Converter Current - Utility Connection ... EPC’s “Standard” Solution

Innovus Power Proprietary- All Rights Reserved 9

Innovus Microgrid Platform Enables Lower LCOE

Engine & Generator

Power Converter System

GridGenius Controller

Innovus FSG Solution Enables

High renewable penetration with grid stability

Efficiency at low loads

Efficient spinning reserves

100% penetration without storage

Stable frequency control

Integrated generation/control

Innovus Microgrid Platform

Page 10: Microgrid Power Systems -   · PDF fileMicrogrid Power Systems ... Control Unit Engine & Generator Power Converter Current - Utility Connection ... EPC’s “Standard” Solution

Innovus Power Proprietary- All Rights Reserved- March 2015

The New Backbone for Distributed Power

Mike Wanebo Innovus Power [email protected] +1.408.455.0358

Page 11: Microgrid Power Systems -   · PDF fileMicrogrid Power Systems ... Control Unit Engine & Generator Power Converter Current - Utility Connection ... EPC’s “Standard” Solution

11 Innovus Power Proprietary- All Rights Reserved- March 2015

FSGs cost rise with high renewable penetration

100% fossil fuel power 100% Peak Power from Renewables

Le

ve

lize

d C

ost

of

Ener

gy

(LC

OE)

LCOE of Renewables Plus Dispatchable Fixed Speed Generator (FSGs)

Cost increase assets are added to stabilize Grid

Maximum penetration without stability issues

Increasing Renewables

Fixed Speed Generator (FSG)

Page 12: Microgrid Power Systems -   · PDF fileMicrogrid Power Systems ... Control Unit Engine & Generator Power Converter Current - Utility Connection ... EPC’s “Standard” Solution

12 Innovus Power Proprietary- All Rights Reserved- March 2015

Innovus Microgrid Platform deploys the lowest cost power

AC Load

Interchangeable Rack Mount Power Converter Modules Allow for Easy System Configuration

Hybrid Energy Storage

DemandGenius Controller

DC Bus

PowerBridge

Active Rectifier

Inverter

AC

Stablizing

Load

Page 13: Microgrid Power Systems -   · PDF fileMicrogrid Power Systems ... Control Unit Engine & Generator Power Converter Current - Utility Connection ... EPC’s “Standard” Solution

13 Innovus Power Proprietary- All Rights Reserved- March 2015

1 MW

0

200 kW

800 kW

400 kW

600 kW Total Demand Load

Diesel Power utilized

Days

Wind Power Utilized

Current situation with FSG based System

Projected results with Innovus System

Current- Energy by power source*

Customer Case Study: Wind-Diesel Application

Wind power severely curtailed

due to stability issues

Savings 52% below plan

Wind capacity can be fully deployed

Additional energy available for heating

53% reduction in diesel cost

With Innovus- Energy by power source

*Wind turbine in operation since 2012

1 MW

0

200 kW

400 kW

600 kW

800 kW Total Demand Load Diesel Power consumed

Days

Wind Power Utilized

Grid operator will save $525,000 per year in fuel

Wind Turbine Capacity

Wind Turbine Capacity

Page 14: Microgrid Power Systems -   · PDF fileMicrogrid Power Systems ... Control Unit Engine & Generator Power Converter Current - Utility Connection ... EPC’s “Standard” Solution

14 Innovus Power Proprietary- All Rights Reserved- March 2015

The only way to maintain constant 60 Hz ‘AC’ power frequency was fixing the speed of generators

Fixed Speed Generators (FSGs) have serious challenges

Fixed Speed Generators were invented 125 years ago

The Synchronous ‘Fixed Speed’ Generator

Prime Mover Generato

r AC Power

System turns at 1 speed at all loads

Limited ability to handle large and frequent load changes

Limited ability to handle rapid changes in renewable generation

Rapid decline in fuel efficiency as loads decrease

Must be run at high minimum loads to prevent reliability issues

Page 15: Microgrid Power Systems -   · PDF fileMicrogrid Power Systems ... Control Unit Engine & Generator Power Converter Current - Utility Connection ... EPC’s “Standard” Solution

Innovus Power at a glance

• Microgrid Power Systems from up to 25 MW

• Only Variable Speed Generators above 100 kW

Target Markets

Products

• Founded in 2013

• Key IP and asset acquisition in 2012

• Marine Diesel Electric Propulsion since 2002

• Robust patent portfolio and proprietary technologies

• Based in Fremont, CA. near San Francisco

Background & Other

• Microgrids

• Grid Load Defection

• Mining

• Grid Stabilization

• Oil & Gas

• Military

• Construction

• DE Generation

Fremont, CA Headquarters


Recommended