4
© 2016-2018 American Innovations, Ltd. The following procedures are general steps for a typical installation. For specific instructions, see the MicroMax Interrupters User Guide (part no. 122204-000) available from your website account under the Help menu. Installing the Equipment Required Tools Voltmeter Windows ® Laptop PC Bullhorn ® Tools configuration software USB to mini-USB cable Optional Tools (Continued) MicroMax GPS350 Installation and Configuration Part No. 122207-000, Rev. 1 1 of 4 Derating Table Ambient Temperature Interruption Cycle Celsius Fahrenheit 0.8 s ON - 0.2 s OFF 4 s ON - 1 s OFF 25 ⁰C 35 ⁰C 45 ⁰C 55 ⁰C 65 ⁰C 149 ⁰F 95 ⁰F 113 ⁰F 131 ⁰F 77 ⁰F 60 A 60 A 58 A 49 A 38 A 51 A 66 A 78 A 80 A 80 A CAUTION: Metal relay casing on the MicroMax GPS350 will get hot. Allow 5 - 10 minutes after interruption stops before handling the unit. CAUTION: Do not connect the MicroMax GPS350 to primary mains power. WARNING: Before beginning any wiring to the MicroMax GPS350, ensure that power has been turned off at the rectifier. GPS350 Installation & Configuration Quick Reference Guide
Transcript
Page 1: MicroMax GPS350 QRG - testbatweb.bullhornsys.comLocate Power Source for MicroMax GPS350 1 Determine how to power the MicroMax GPS350 using one 1 of the following sources: Tap Change

© 2016-2018 American Innovations, Ltd.

The following procedures are general steps for a typical installation. For specific instructions, see the MicroMax Interrupters User Guide (part no. 122204-000) available from your website account under the Help menu.

Installing the Equipment

Required Tools Voltmeter Windows® Laptop PC

Bullhorn® Tools configuration software USB to mini-USB cable

Optional Tools

(Continued)

MicroMax GPS350Installation and Configuration

Part No. 122207-000, Rev. 11 of 4

Derating Table

Ambient Temperature Interruption Cycle

Celsius Fahrenheit 0.8 s ON - 0.2 s OFF 4 s ON - 1 s OFF

25 ⁰C

35 ⁰C

45 ⁰C

55 ⁰C

65 ⁰C 149 ⁰F

95 ⁰F

113 ⁰F

131 ⁰F

77 ⁰F 60 A

60 A

58 A

49 A

38 A 51 A

66 A

78 A

80 A

80 A

CAUTION: Metal relay casing on the MicroMax GPS350 will get hot. Allow 5 - 10 minutes after interruption stops before handling the unit.

CAUTION: Do not connect the MicroMax GPS350 to primary mains power.

WARNING: Before beginning any wiring to the MicroMax GPS350, ensure that power has been turned off at the rectifier.

GPS350 Installation & ConfigurationQuick Reference Guide

MicroMax GPS350Installation and Configuration

Page 2: MicroMax GPS350 QRG - testbatweb.bullhornsys.comLocate Power Source for MicroMax GPS350 1 Determine how to power the MicroMax GPS350 using one 1 of the following sources: Tap Change

(Continued)

Quick Reference Guide

Part No. 122207-000, Rev. 12 of 4

MicroMax GPS350 Quick Reference Guide

January 2017

1 To interrupt the AC power:

Connect Relay to Rectifier

GPS350 Relay Connected to Rectifier

Positive Output

2 To interrupt the DC power:

NOTE: These connections are not polarity sensitive.

b Slide shrink wrap tube (provided) onto the second MicroMax GPS350 relay cable.

d Wrap assembly with shrink wrap to prevent equipment shorting.

GPS350 Relay Cable & DC Output Cable

GPS350 Relay Cable & DC Output Cable Wrapped

a Remove the tap change bar from the taps.

b Connect the two MicroMax GPS350 relay wires to the taps.

NOTE: Connect relay wires to the same taps that were connected by the change bar.

c Connect the MicroMax GPS350 relay cable to the DC output cable using available hardware.

a Disconnect the DC output cable. Then connect one of the MicroMax GPS350 relay cables to output.

GPS350 Relay Connected to Rectifier AC

CAUTION: Do not connect the MicroMax GPS350 to primary power.

2

Locate Power Source for MicroMax GPS350 1 Determine how to power the MicroMax GPS350 using one

of the following sources:1

Tap Change Bar

a Rectifier — with power turned on to the rectifier, use a voltmeter to locate a power source across any two available AC taps. The MicroMax GPS350 requires 8 - 42 V AC.

b A 120 V AC convenience outlet with the 12 V DC wall adapter.

c A DC source, such as a 10 - 60 V DC battery.2 Turn off rectifier power.

POWER DEVICE WITH:

FINE/COARSE TAPS8 V - 42 V AC

OR

12 V DC WALL ADAPTER

OR

BATTERY 10 V - 60 V DC

Page 3: MicroMax GPS350 QRG - testbatweb.bullhornsys.comLocate Power Source for MicroMax GPS350 1 Determine how to power the MicroMax GPS350 using one 1 of the following sources: Tap Change

Part No. 122207-000, Rev. 1

(Continued)

MicroMax GPS350 Quick Reference Guide

3 of 4© 2016-2017 American Innovations,

Power

GPS AntennaConnection

Connect Power Cable

Connect GPS Antenna Cable toMicroMax GPS350

3 Connect red/white twisted wire cable to INPUT connection on Power Cable. Then clip alligator clips to rectifier AC taps. Voltage range is 8 - 42 V AC.

1 Connect GPS antenna cable to MicroMax GPS350 GPS Antenna connection.

2 Place GPS antenna outside of rectifier in an area with a clear view of the sky.

1 Connect Power Cable to MicroMax GPS350 Power connection.

GPS350 Power Connection

2 OPTIONAL: If external relay is used, connect relay control or coil to Power Cable OUTPUT. Be sure to observe proper polarity, especially if a flyback diode is present on a mercury relay coil.

Power CableOUTPUT

Alligator Clipson Rectifier Taps

Power Cable

GPS Antenna GPS350 GPSAntenna Connection

Twisted Wire Cable Connected to Power Cable

Power

GPS AntennaConnection

4

3

WARNING: Ensure that the antenna connection does not come into contact with any conductive surface of the rectifier.

Page 4: MicroMax GPS350 QRG - testbatweb.bullhornsys.comLocate Power Source for MicroMax GPS350 1 Determine how to power the MicroMax GPS350 using one 1 of the following sources: Tap Change

Part No. 122207-000, Rev. 1January 20174 of 4

MicroMax GPS350 Quick Reference Guide

Program MicroMax GPS350 5

9 Close and lock the clear cover on the MicroMax GPS350. Place interrupter inside the rectifier.

a Press to select interruption schedule - Daily, Continuous, or Start/Stop.

b Use and to move through fields; use keypad to change settings.

c Press to begin program.

to move through fields; use to move through fields; use

6 For Interruption, enter a number between 1 and 9 for the program number.

1 Power on the rectifier.

2 Press to view GPS information.

3 Use and to change display contrast.

4 OPTIONAL: From the main menu, press to

run Test Mode. Press to return to main menu.

5 Press to set up an Interruption program ORto set up an Interference program.

to change display contrast. to change display contrast.

Press to set up an Press to set up an

Press to view GPS information. Press to view GPS information.

MicroMax GPS350 Main Menu

12:01:03 02/25

1:Interrupt 2:GPS

3:Interference

4:Options :Test

Interruption Program

# 5 On 12.0 Off 03.0

Start 06:00 01/01/14

Stop 18:00 12/31/99

Change: / Set:Change: / Set:

#10 On 13.0 Off 05.0

Delay 002.0

Cycle Time 0088s

Unit #07/10 Next:

Interference Program

8 For Interference:

a Use and to move through fields. Use keypad to change settings.

b Press to select type of interruption.

c Press to select interruption schedule - Daily,

Continuous, or Start/Stop.

d Use and to move through fields. Use

keypad to change settings.

e Press to begin program.

to move through fields. Use to move through fields. Use

a Press to access a list of Options and thento view or edit Switch and Int. Cycle options.

b To change settings, move the cursor to the option and press .

7 For Interruption Output Parameters:

To change settings, move the cursor to the optionTo change settings, move the cursor to the option and press . and press .

Switch: Norm Closed

Int. Cycle: ON/OFF

Move: Change:

Done: Cancel:PREVDone: Cancel:PREV

Move: Change:Move: Change:Move: Change:

Done: Cancel:PREVDone: Cancel:PREV

Out Parameters

The following procedures are general steps for programming the GPS350 using the unit keypad. For instructions on programming the unit with Bullhorn Tools, refer to the online help available from the Bullhorn Tools Help menu or to the MicroMax Interrupters User Guide.


Recommended