M2000 V200R013 Performance
Management
Confidential Information of Huawei. No
Spreading Without Permission 1
www.huawei.com
Copyright © 2013 Huawei Technologies Co., Ltd. All rights reserved.
M2000 V200R013Performance Management
Copyright © 2013 Huawei Technologies Co., Ltd. All rights reserved. Page1
Objectives
� Upon completion of this course, you will be able to:
� Understand the role of performance management in the M2000.
� Perform performance management operations.
M2000 V200R013 Performance
Management
Confidential Information of Huawei. No
Spreading Without Permission 2
Copyright © 2013 Huawei Technologies Co., Ltd. All rights reserved. Page2
Contents
1. Basic Concept of Performance Management
2. Preferences Settings
3. Database Capacity Parameters
4. Measurement Management
5. Custom Counter Management
6. Querying Performance Measurement Results
7. Missing Result Diagnosis Tool
8. Other Functions
Copyright © 2013 Huawei Technologies Co., Ltd. All rights reserved. Page3
Overall Performance Management Process
M2000 V200R013 Performance
Management
Confidential Information of Huawei. No
Spreading Without Permission 3
Copyright © 2013 Huawei Technologies Co., Ltd. All rights reserved. Page4
Overall Performance Management Process
Copyright © 2013 Huawei Technologies Co., Ltd. All rights reserved. Page5
Process of Recollecting Performance data
M2000 V200R013 Performance
Management
Confidential Information of Huawei. No
Spreading Without Permission 4
Copyright © 2013 Huawei Technologies Co., Ltd. All rights reserved. Page6
Three Mandatory Elements of Performance
Measurement� Measurement counter: What is to be measured?
� System counters: common counters and extended counters
� Custom counters
� Measurement object: Who is to be measured?
� Physical objects (boards and subracks)
� Logical objects (eNodeBs, cells, and TRXs)
� Measurement period: How to measure?
� 5-minute, 15-minute, 30-minute, 60-minute, and 24-hour
Copyright © 2013 Huawei Technologies Co., Ltd. All rights reserved. Page7
Three Mandatory Elements of Performance Measurement
Measurement objects (logical) Measurement period Measurement counter
M2000 V200R013 Performance
Management
Confidential Information of Huawei. No
Spreading Without Permission 5
Copyright © 2013 Huawei Technologies Co., Ltd. All rights reserved. Page8
Measurement Counter
� The following figure shows the hierarchical structure of
measurement counters:
Function subset m
Function subset 1
Function set 1
……
…
Function set n
Counter 1
Counter j
Counter 1
Counter k
Performance
Copyright © 2013 Huawei Technologies Co., Ltd. All rights reserved. Page9
Measurement Counter (Continued)
Function set
Function subset
Measurement
counter
M2000 V200R013 Performance
Management
Confidential Information of Huawei. No
Spreading Without Permission 6
Copyright © 2013 Huawei Technologies Co., Ltd. All rights reserved. Page10
Contents
1. Basic Concept of Performance Management
2. Preference Settings
3. Database Capacity Parameters
4. Measurement Management
5. Custom Counter Management
6. Querying Performance Measurement Results
7. Missing Result Diagnosis Tool
8. Other Functions
Copyright © 2013 Huawei Technologies Co., Ltd. All rights reserved. Page11
Preferences SettingsSee 1-PM Preferences.mp4.
Or
M2000 V200R013 Performance
Management
Confidential Information of Huawei. No
Spreading Without Permission 7
Copyright © 2013 Huawei Technologies Co., Ltd. All rights reserved. Page12
Contents
1. Basic Concept of Performance Management
2. Preferences Settings
3. Database Capacity Parameters
4. Measurement Management
5. Custom Counter Management
6. Querying Performance Measurement Results
7. Missing Result Diagnosis Tool
8. Other Functions
Copyright © 2013 Huawei Technologies Co., Ltd. All rights reserved. Page13
Database Capacity Parameters
M2000 V200R013 Performance
Management
Confidential Information of Huawei. No
Spreading Without Permission 8
Copyright © 2013 Huawei Technologies Co., Ltd. All rights reserved. Page14
Database Capacity Parameters
Copyright © 2013 Huawei Technologies Co., Ltd. All rights reserved. Page15
Contents
1. Basic Concept of Performance Management
2. Preferences Settings
3. Database Capacity Parameters
4. Measurement Management
5. Custom Counter Management
6. Querying Performance Measurement Results
7. Missing Result Diagnosis Tool
8. Other Functions
M2000 V200R013 Performance
Management
Confidential Information of Huawei. No
Spreading Without Permission 9
Copyright © 2013 Huawei Technologies Co., Ltd. All rights reserved. Page16
Process of Querying Performance Measurement Results
Set performance measurement.
Query measurement results.
•Measurement counters
•Measurement objects
•Measurement period
•By criteria
•By template
Step 1
Step 2
Copyright © 2013 Huawei Technologies Co., Ltd. All rights reserved. Page17
Setting Performance Measurement
See 2-Measurement Settings.mp4.
Measurement period
Measurement
counter
Measurement object
M2000 V200R013 Performance
Management
Confidential Information of Huawei. No
Spreading Without Permission 10
Copyright © 2013 Huawei Technologies Co., Ltd. All rights reserved.
Diagnosing Missing Objects
Page18
� Operation entry: Click Diagnose Object Missing on the Measurement Management tab page. The Diagnose Object Missing dialog box is displayed.
Copyright © 2013 Huawei Technologies Co., Ltd. All rights reserved.
Principle of Missing Object Diagnosis
� The process of creating measurement objects is as follows:
Page19
NE M2000
configuration
module
M2000performance
module
M2000performance
database
Filter
criteria
Object
model
M2000 V200R013 Performance
Management
Confidential Information of Huawei. No
Spreading Without Permission 11
Copyright © 2013 Huawei Technologies Co., Ltd. All rights reserved. Page20
Contents
1. Basic Concept of Performance Management
2. Preferences Settings
3. Database Capacity Parameters
4. Measurement Management
5. Custom Counter Management
6. Querying Performance Measurement Results
7. Missing Result Diagnosis Tool
8. Other Functions
Copyright © 2013 Huawei Technologies Co., Ltd. All rights reserved. Page21
Customizing Counters
� Use the User-defined Counter Management to customize new
counters based on existing counters.
See 3-User-Defined Counter.mp4.
M2000 V200R013 Performance
Management
Confidential Information of Huawei. No
Spreading Without Permission 12
Copyright © 2013 Huawei Technologies Co., Ltd. All rights reserved. Page22
Customizing Counters (Continued)Existing custom counter
Enter a constant
in the brackets.
Existing counters
Example: (Counter 1 + Counter 2) x {100}/(Counter 3 + Counter 4 + Counter 6)
Measurement
Period for the customizing
counter
Copyright © 2013 Huawei Technologies Co., Ltd. All rights reserved. Page23
Contents
1. Basic Concept of Performance Management
2. Preferences Settings
3. Database Capacity Parameters
4. Measurement Management
5. Custom Counter Management
6. Querying Performance Measurement Results
7. Missing Result Diagnosis Tool
8. Other Functions
M2000 V200R013 Performance
Management
Confidential Information of Huawei. No
Spreading Without Permission 13
Copyright © 2013 Huawei Technologies Co., Ltd. All rights reserved. Page24
Querying Performance Measurement Results
� Two modes are provided for querying performance
measurement results:
� By criteria
� By template
See 4-Querying Performance Results.mp4.
Copyright © 2013 Huawei Technologies Co., Ltd. All rights reserved. Page25
By Criteria
The counters are set to be
measured for at least one NE at
the period.
M2000 V200R013 Performance
Management
Confidential Information of Huawei. No
Spreading Without Permission 14
Copyright © 2013 Huawei Technologies Co., Ltd. All rights reserved. Page26
By Criteria (Continued)
Some counters can be
queried by using this
option. This option
becomes available after
Function subset is
selected in the
Organization Style area.
The criteria can be
saved as a query
template.
Copyright © 2013 Huawei Technologies Co., Ltd. All rights reserved. Page27
By Template
M2000 V200R013 Performance
Management
Confidential Information of Huawei. No
Spreading Without Permission 15
Copyright © 2013 Huawei Technologies Co., Ltd. All rights reserved. Page28
Contents
1. Basic Concept of Performance Management
2. Preferences Settings
3. Database Capacity Parameters
4. Measurement Management
5. Custom Counter Management
6. Querying Performance Measurement Results
7. Missing Result Diagnosis Tool
8. Other Functions
Copyright © 2013 Huawei Technologies Co., Ltd. All rights reserved.
Diagnosing Missing Measurement Results
Page29
See 5-Result Loss Diagnosing .mp4.
M2000 V200R013 Performance
Management
Confidential Information of Huawei. No
Spreading Without Permission 16
Copyright © 2013 Huawei Technologies Co., Ltd. All rights reserved. Page30
Contents
1. Basic Concept of Performance Management
2. Preferences Settings
3. Database Capacity Parameters
4. Measurement Management
5. Custom Counter Management
6. Querying Performance Measurement Results
7. Missing Result Diagnosis Tool
8. Other Functions
Copyright © 2013 Huawei Technologies Co., Ltd. All rights reserved. Page31
Other Functions
� Handling Abnormal Status
� Browsing the measurement Status
� Synchronizing Measurement Results
� Diagnosing Missing Objects
� Counter Threshold Management
M2000 V200R013 Performance
Management
Confidential Information of Huawei. No
Spreading Without Permission 17
Copyright © 2013 Huawei Technologies Co., Ltd. All rights reserved. Page32
Browsing Measurement Status
Legends
See 6-Browse Measurement Status.mp4.
Copyright © 2013 Huawei Technologies Co., Ltd. All rights reserved. Page33
Synchronizing Measurement Results� When some measurement results are missing, you can recollect the missing
data by synchronizing the measurement results. The Synchronize Result
dialog box is on page 40.
M2000 V200R013 Performance
Management
Confidential Information of Huawei. No
Spreading Without Permission 18
Copyright © 2013 Huawei Technologies Co., Ltd. All rights reserved. Page34
Synchronizing Measurement Results (Continued)
Copyright © 2013 Huawei Technologies Co., Ltd. All rights reserved. Page35
Synchronizing Measurement Results (Continued)
See 7-Synchronizing Measurement Results.mp4.
M2000 V200R013 Performance
Management
Confidential Information of Huawei. No
Spreading Without Permission 19
Copyright © 2013 Huawei Technologies Co., Ltd. All rights reserved. Page36
Counter Thresholds
� Benefits
� The system monitors the results of the measurement counters of some
measurement objects. If the result of a measurement counter exceeds the
preset threshold, the system generates an alarm.
� Threshold Types
� Simple thresholds
� Thresholds for single counters
� Composite thresholds
� Thresholds for the logical or arithmetic operation results of multiple
counters.
See 8-Performance Counter Threshold.mp4.
Copyright © 2013 Huawei Technologies Co., Ltd. All rights reserved. Page37
Simple Thresholds
M2000 V200R013 Performance
Management
Confidential Information of Huawei. No
Spreading Without Permission 20
Copyright © 2013 Huawei Technologies Co., Ltd. All rights reserved. Page38
Threshold Alarm
Minor alarm
Critical alarm
Clear the critical alarm.
Clear the minor alarm.
110
100
90
45
40
35
t1 t2 t3 t4 t5 t6 t7 t8 t9 t10 t11 t12
� The higher the value, the
worse the situations.
Copyright © 2013 Huawei Technologies Co., Ltd. All rights reserved. Page39
Threshold Alarm (Continued)
Minor alarm
Critical alarm
Clear the critical alarm.
Clear the minor alarm.
110
100
90
45
40
35
t1 t2 t3 t4 t5 t6 t7 t8 t9 t10
� The lower the value, the
worse the situations.
M2000 V200R013 Performance
Management
Confidential Information of Huawei. No
Spreading Without Permission 21
Copyright © 2013 Huawei Technologies Co., Ltd. All rights reserved. Page40
Composite Threshold
Set the formula in the
Set Triggering
Conditions dialog box.
� The total number of simple thresholds and composite thresholds must be
smaller than or equal to 100.
� The specifications of monitorable object quantity are added. For example,
the quantity of monitorable objects for mid-range M2000 is 200,000.
Copyright © 2013 Huawei Technologies Co., Ltd. All rights reserved. Page41
Composite Threshold (Continued)
The counter name can display different counters
according to the counter type.
Logical
M2000 V200R013 Performance
Management
Confidential Information of Huawei. No
Spreading Without Permission 22
Copyright © 2013 Huawei Technologies Co., Ltd. All rights reserved. Page42
Exercises
1. Save a service statistical result file, which must meet the following
conditions:
2. Query a service statistical result file by template, and ensure that the
result file meets the preceding conditions.
Object eNodeB or others (depends on the actual situations)
Counter All counters for user number measurement unit
Time Morning, afternoon, and busy hours in the evening
Date Last two days
Period 60-minute
Copyright © 2013 Huawei Technologies Co., Ltd. All rights reserved. Page43
Exercises
Object eNodeB or others (depends on the actual situations)
Threshold Name BBUBoard: BBUBoard.CPULoad.Mean
Time 60-minute
Activation Date All January and August
Period 60-minute
Threshold Type Simple
Tendency Descending
Function Subset Equipment Performance Measurement
Counter Name BBUBoard: BBUBoard.CPULoad.Mean
Threshold Critical: 5
Major: 2
Minor: 1
Warning: 0.5
Delay 0.5
0.5
0.2
0.2
3、Set a threshold for the following counter and query its alarm.