A POWERFUL CHOICE FOR I.V. THERAPIESThe PowerMidline™ Catheter and Bard® Poly Midline o�er reliable short-term peripheral access (less than 30 days) to the venous system for selected intravenous therapies and blood sampling. The PowerMidline™ Catheter and Bard® Poly Midline Max Barrier and Full trays contain many of the same high-quality kit components as Bard® PowerPICC® Catheter trays.
BENEFITS• Available in Full and Max Barrier kit nursing configurations with Modified Seldinger Technique (MST) components
• Helps to improve patient comfort due to the potential for decreased needle sticks
• Body-softening polyurethane helps minimize vessel wall trauma
• No x-ray required during the placement procedure
• StatLock® Stabilization Device compatible
A POWERFUL CHOICE FOR I.V. THERAPIESThe PowerMidline™ Catheter and Bard® Poly Midline o�er reliable short-term peripheral access (less than 30 days) to the venous system for selected intravenous therapies and blood sampling. The PowerMidline™ Catheter and Bard® Poly Midline Max Barrier and Full trays contain many of the same high-quality kit components as Bard® PowerPICC® Catheter trays.
• Available in Full and Max Barrier kit nursing configurations with Modified Seldinger Technique (MST) components
• Helps to improve patient comfort due to the potential for decreased needle sticks
• Body-softening polyurethane helps minimize vessel wall trauma
Unique hub design further identifies the catheter as a midline which
helps liminate atheter confusion and promotes patient safety.
20 cm Length - distally trimmable allows for customization to ndividual atient’s anatomy.
Reverse taper gently plugs the insertion s te and provides
excellent kink-resistance.
Clea ly labeled as a midli e catheter to assist with ca heter identification.
POWER-INJECTABLE MIDLINE*
Unique hub design further identifies the catheter as a midline which
helps eliminate catheter confusion and promotes patient safety.
20 cm Length - distally trimmable allows for customization to
individual patient’s anatomy.
Reverse taper gently plugs the insertion site and provides
excellent kink-resistance.
Clearly labeled as a midline catheter to assist with catheter identification.
POWER-INJECTABLE MIDLINE*
*Please consult PowerMidline™ Catheter labels and inserts for power injection warnings, precautions and directions for use.
PRODUCT CODE CATHETER SIZE LUMENS TRAY AVERAGE PRIMING VOLUME (ML)
MAX ACHIEVABLE PUMP FLOW RATE1 (ML/HR)
AVERAGE GRAVITY FLOW RATE2 (ML/HR) LUMEN SIZE
4153108D 3 F Single Max Barrier 0.31 Saline (1.0 cP) > 999 708 20 G
4153108 3 F Single Full 0.31 Saline (1.0 cP) > 999 708 20 G
4154108D 4 F Single Max Barrier 0.41Saline (1.0 cP) > 999Blood (3.5 cP) = 959
1988 18 G
4154108 4 F Single Full 0.41Saline (1.0 cP) > 999Blood (3.5 cP) = 959
1988 18 G
PRODUCT CODE CATHETER SIZE LUMENS TRAY AVERAGE PRIMING
VOLUME (ML)MAX ACHIEVABLE PUMP FLOW RATE1 (ML/HR)
POWER INJECTION RATE (ML/SEC)
AVERAGE GRAVITY FLOW RATE2 (ML/HR)
LUMEN SIZE
P4153108D 3 F Single Max Barrier 0.31 Saline (1.0 cP) > 999 3 729 20 G
P4153108 3 F Single Full 0.31 Saline (1.0 cP) > 999 3 729 20 G
P4154108D 4 F Single Max Barrier 0.37Saline (1.0 cP) > 999Blood (3.5 cP) = 959
7 2116 18 G
P4154108 4 F Single Full 0.37Saline (1.0 cP) > 999Blood (3.5 cP) = 959
7 2116 18 G
Bard® Poly Midline | Product Ordering Information & Specifications
PowerMidline™ Catheter | Product Ordering Information & Specifications
1. Estimates based on a pump alarm setting of 500 mmHg and full length catheter at 20 cm. 2 Testing performed using water.
Please consult product labels and inserts for any indications, contraindications, hazards, warnings, cautions and instructions for use.
BARD ACCESS SYSTEMS, INC. • 605 North 5600 West • Salt Lake City, Utah 84116 USA • Main: 801-522-5000 • Customer Service: 1-800-545-0890
Clinical Information: 1-800-446-3385 • www.bardaccess.com
Bard, StatLock, and PowerMidline are trademarks and/or registered trademarks of C. R. Bard, Inc. All other trademarks are the property of their respective owners. © 2016 C. R. Bard, Inc. All rights reserved. BAS/PWRM/0116/0003
Indications for Use: The Bard® Poly Midline catheters are indicated for short-term (less than 30 days) peripheral access to the peripheral venous system for selected intravenous therapies and blood sampling (See Contraindications). For blood therapy, it is recommended that a 4 French or larger catheter be used.
Indications for Use: The PowerMidline™ Catheters are indicated for short term access to the peripheral venous system for selected intravenous therapies, blood sampling, and power injection of contrast media. These catheters may be used for any patient population with consideration given to adequacy of vascular anatomy and appropriateness of the procedure. The PowerMidline™ Catheters are suitable for use with power injectors.
1. Estimates based on a pump alarm setting of 500 mmHg and full length catheter at 20 cm. 2 Testing performed using water.