3
For Technical Support: www.panduit.com/resources/install_maintain.asp INSTALLATION INSTRUCTIONS © Panduit Corp. 2015 PN366M Page 1 of 3 Strain relief clip Jack Wire cap Blue - Cat. 6A White - Cat. 6 Red - Cat. 5e 2.00" (50.8mm) Drain Wire CWST S/FTP Individual foil pair screen Conductors Braid U/FTP Individual foil pair screen Conductors Drain wire F/UTP Overall foil screen Conductors Drain wire SF/UTP Overall foil screen Conductors Braid 2.00" (50.8mm) 0.50" (12.7mm) CWST 0.50" (12.7mm) CWST 2.00" (50.8mm) 2.00" (50.8mm) 0.50" (12.7mm) Drain Wire CWST Mini-Com Shielded Jack Modules - TG Style Termination Part Numbers: CJS6X88TG**Y, CJSK6X88TG**, CJSQ6X88TGBL, CJSH6X88TG**Y, CJS688TG**Y, CJSK688TG**, CJSQ688TG**, CJSH688TG**Y, CJS5E88TG**Y, CJSK5E88TG**, CJSH5E88TG**Y ** = color. CABLE PREPARATION STEPS
Transcript

For Technical Support: www.panduit.com/resources/install_maintain.asp

INSTALLATION INSTRUCTIONS © Panduit Corp. 2015 PN366M

Page 1 of 3

Strain relief clip

Jack

Wire capBlue - Cat. 6AWhite - Cat. 6Red - Cat. 5e

2.00"(50.8mm)

DrainWire

CWST

S/FTP

Individual foil pair screen

Conductors

Braid

U/FTP

Individual foil pair screen

Conductors

Drain wire

F/UTP

Overall foil screen

Conductors

Drain wire

SF/UTP

Overall foil screen

Conductors

Braid

2.00"(50.8mm)

0.50"(12.7mm)

CWST

0.50"(12.7mm)

CWST2.00"

(50.8mm)

2.00"(50.8mm)

0.50"(12.7mm)

Drain Wire

CWST

Mini-Com Shielded Jack Modules - TG Style Termination

Part Numbers: CJS6X88TG**Y, CJSK6X88TG**, CJSQ6X88TGBL, CJSH6X88TG**Y, CJS688TG**Y, CJSK688TG**, CJSQ688TG**, CJSH688TG**Y, CJS5E88TG**Y, CJSK5E88TG**, CJSH5E88TG**Y

** = color.

CABLE PREPARATION STEPS

For Technical Support: www.panduit.com/resources/install_maintain.asp

INSTALLATION INSTRUCTIONS © Panduit Corp. 2015 PN366M

Page 2 of 3

TERMINATION STEPS

6EGJT

5

Do not pre-arrange conductors.

(OR)

4

2

32

0.5"(12.7mm)

1

Trim pair separator and/or ripcord, if present.

7 T568B Wiring

(OR)

1.

1. 2.

R

F

R

F

T568A Wiring7

(OR)

1.

1.

R

F

R

F

2.

2.

INSTALLATION INSTRUCTIONS © Panduit Corp. 2015 PN366M

For Instructions in Local Languagesand Technical Support:

www.panduit.com/resources/install_maintain.asp www.panduit.com

E-mail:[email protected]

Phone: 866-405-6654

Page 3 of 3

REMOVAL STEPS

1 2 3

Notes:1. For specified performance, follow TIA/EIA 568-C installation guidelines.2. Shielded jack modules can terminate 22-26 AWG solid or stranded IWC data cable with 0.062" (1.57mm) maximum insulated conductor outside diameter.3. Shielded jack modules may be re-terminated a minimum of 20 times.4. For technical and performance information, contact Panduit Technical Support.5. CJSGK-X Grounding Kit is REQUIRED for all Mini-Com Modular Patch Panels, but is optional for Mini-Com All Metal Shielded Modular Patch Panels.

As with all Communication Components, the following statements apply:1. Never install communications wiring during a lightning storm.2. Never install communications wiring in wet locations unless the jack is specifically designed for use in wet locations.3. Never touch uninsulated communications wiring or terminals unless the communication line has been disconnected at the network interface.4. Use caution when installing or modifying communication wiring.

11EGJT

12 13

Grounding Kit,

(See note 5)CJSGK-X

8 Trim conductorsflush

9

Trim drain wire,if present

10