MINIIMIZE THE HASSLE OF ESR TESTING IN YOUR LAB *miniiSED ® is a registered trademark of ALCOR Scientific Inc. ®
Transcript
Page 1: MINIIMIZE THE HASSLE OF ESR TESTING IN ... - Alcor Scientific...24 x 18 x 26 cm (9.5 x 7.1 x 10.4 in) Principle of measure Analytical range Sample requirements Tube requirements Barcode

MINIIMIZE THE HASSLE OFESR TESTING IN YOUR LAB

*miniiSED® is a registered trademark of ALCOR Scientific Inc.

®

Page 2: MINIIMIZE THE HASSLE OF ESR TESTING IN ... - Alcor Scientific...24 x 18 x 26 cm (9.5 x 7.1 x 10.4 in) Principle of measure Analytical range Sample requirements Tube requirements Barcode

+1 (401) 737.4519 | www.alcorscientific.comminiSED® is a registered trademark of ALCOR Scientific Inc.

HOW miniSED® WORKS

The miniSED® utilizes photometric readings to quantify the Rouleaux formation, which is the earliest and most critical phase of sedimentation.

Results are obtained less than 17 seconds!

The miniSED® technology makes it possible to eliminate variables commonly associated with traditional ESR methodologies, such as hematocrit, MCV and temperature.

IDEAL FOR EMERGENCY ROOMS, POL, AND IDEAL AS A BACKUP ANALYZER IN THE TYPICAL HOSPITAL LABORATORY.

EVERYTHING YOU NEED TO GET STARTEDminiSED® Automated ESR Analyzer

Test Card of various denominations

Seditrol® Quality Control Kit

Photometrical rheoscope

1-130mm/hr

100μL whole blood (500μL dead volume)

13 x 75mm test tube in EDTA anti-coagulant, capped

Internal

Serial RS232 port for LIS connection

100-240VAC; 50-60Hz; 160W

Human-based quality control

24 x 18 x 26 cm (9.5 x 7.1 x 10.4 in)

Principle of measure

Analytical range

Sample requirements

Tube requirements

Barcode reader

Interface

Power requirements

Quality control

Dimensions

SPECIFICATIONS

RHEOLOGY TECHNOLOGY The miniiSED® is the latest addition to the line of Erythrocyte Sedimentation Rate (ESR) analyzers from ALCOR Scientific Inc. The miniiSED® is a single position, fully automated ESR analyzer that works directly from the primary EDTA tube and requires just 100 microliters of sample to deliver a result in just 15 seconds. The miniiSED’s small footprint and advanced features like its integrated barcode reader and touch screen user interface, together with its rapid time to result make it the ideal solution to ESR testing for small laboratories, POL’s, and emergency clinics. ALCOR Scientific utilizes photometric reading to quantify the Rouleaux formation, which is the earliest and most critical phase of sedimentation. Our analyzers’ micro-flow cell captures the critical kinetics of RBCs in a highly controlled testing environment to produce ESR results in 15-20 seconds. The analyzers’ results are unaffected by variables commonly associated with traditional ESR testing methods. Some of these variables include hematocrit, MCV, and temperature.

MINIIMIZE TATFast, accurate and reliable results in just 15 seconds.

MINIIMIZE COSTSImprove workflow while reducing test time and money spent running sed rates.

MINIIMIZE SAMPLE SIZEOnly 100μL of sample is required for testing.

®

ALCORSCIENTIFIC.COM

1017-09-200 02/2020