MistCatcherVOL4.indd
MCA-05 MCA-07 MCA-15MCA-05
2
WWJ
1. 1. Spreads the air and extends the area of the filter. 2. 1st 2.
Filters grainy mist and prevents the chips from entering. 3. 2nd
1st 3. Filters the rest of mist from the first filter.
2nd Second filter (Drum type)
Integrated sheet metal design to prevent oil from leaking
Using spot welding and calking material will cause oil leaking due
to time passing.
1st First filter
High efficiency and energy saving motor application
Model MCA-05 MCA-07 MCA-15 Out power [kW] 0.375 0.75 1.5 Suction
inlet diameter [mm] φ 123 φ 148 φ 148 Poles/Phase 2pole 2pole 2pole
Voltage [V] 200 220 380 200 220 380 200 220 380 Frequency [Hz] 50
60 50 60 50 60 50 60 50 60 50 60 50 60 50 60 50 60 Current [A] 2.09
1.98 1.9 1.8 1.8 1.04 3.65 3.47 3.32 3.15 1.92 1.82 6.93 6.73 6.3
6.12 3.65 3.54 1.1 1.1 1.7 1.6 2.7 3.5 Maximum capacity [m3/min]
8.3 10 8.3 10 8.3 10 10.5 13 10.5 13 10.5 13 17 20 17 20 17 20 Size
L × W × H [mm] 568 × 310 × 451 573 × 360 × 463 683 × 433 × 595
Weight [kg] 30.5 34 54 [ºC] 50 50 50
99.7%
Mist Catcher is three-stage filter structure, developed by our
company, which can collect 99.7% from big to small size mist.
3
WWJ
The product equips the basic functions with reasonable price.
1 Mist Catcher was developed to pursue for low cost based on the
assurance of basic performance. It can operate for both water-base
and oil-base mist. Quick maintenance can be finished in one minute
with the design that you can change th e filter easily. The mist
catcher is energy-saving with the highly efficiency motor.
• Applicable for all kinds of oil mist & water mist
99.7 Collect 99.7% mist which is great or small through three-stage
filter structure.
• Low noise 74db
Only 74dB of low noise with low price
• Easy maintenance 2 The cover can be opened only unfasten the
buckles at both sides. Filter can be exchanged without any tool.
Consumable filters are set at lower price.
• Energy saving
Applying high efficiency motor not only save energy but also make
some efforts to global warming prevention.
• Applicable to specifications worldwide CE
In order to internationalize, we obtain the CE certification in
Europe.
•1 One year limited warranty (The warrant does not cover consumable
parts.)
• Depending on each country, standard electric voltage is
changeable. (When ordering, specify the electric voltage.)
• Performance curve
MIST COLLECTOR/MIST CATCHER
50Hz 1.4
0.8 0.6 0.4 0.2 0
[m3/min] [m3/min] 1614121086420 18
MCA-05 MCA-05 MCA-07 MCA-07
F-123 1
SM-125 1
2P-125 2
H-140 4
16mm
MS-05 1
⇔ 3m ⇔ 2m PVC CONTROL CABLE 1.25mm2× 4C 600V R1.25-5
4
1st MCA-05 1st 1
2nd MCA-05 2nd 1
1 5P13 2 3
TS-15H TS-153rd TS-15H_2
3rd Must install before installing 3rd filter
3rd Simple type 3rd filter
2 Applicable for both water soluble and oiliness cutting
fluid*2
Dimensional drawing 4
Noise reduction board
Dimensional drawing 5
Air intake duct
φ 125 5m10m15m Choose the length from φ 125 5m, 10m, 15m
3rd 1
2 3rd
Please kindly install the noise reduction board if has no 3rd
filter. *1 Using oiliness cutting fluid and having fire protection
inside machine,
we recommend to install fire damper device. *2 The collection rate
is lower than 3rd filter.
Optional parts
φ350 683
Selection method
High airtightness within a cover Qm3/minW× D× H×α Q
Mist Catcher airflow W× D× H m3
Cubic content α
Experience 3 4 Less amount of mist and less times of the cover
closing and opening = 3 Lots of mist and more times of the cover
closing and opening = 4
Hz Voltage
MCA-05 10
MCA-07 13
MCA-15 20
Machine center (Installing on the top) Machine center (Using fixed
frame) Lathe Electric discharge machine
Low airtightness without a cover Qm3/minA× B× V(m/min) Q
Mist Catcher airflow A× B m2
The area of opening V 7 15m/min
The requirement of airspeed in absorbing oil mist (0.5m/s) (=
7-15m/min)
Installation examples
↓ ↓ HEPA 0.3μ MCA-05/07 3rd HEPA 0.3µ MCA-05 3rd TS-05H MCA-05 3rd
TS-05_2
MCA-05/07 3rd HEPA 0.3µ MCA-07 3rd TS-07 MCA-07 3rd TS-07H
MCA-15 3rd HEPA 0.3Mµ MCA-15 3rd TS-15 MCA-15 3rd TS-15_2
3rd
12
WWJ
3rd 1st2nd
2 Unlock two snap locks, and open the cover.
1st Remove the first frame.
1st Replace the first filter.
2nd Replace the second filter.
1 1 minute maintenance
Maintenance
13
WWJ
MCA-15 HEPA 0.3µ 600212
MCA 600204
We offer a rental service of the tool for installation.
2-M12 If install on the upper end of machine, please kindly refer
to the following dimension place for processing.
To install a flange to machine cover, please kindly refer to the
following dimension place for processing.
φ7 φ7
14
495
3
MCA-07 5 1kWh20 0.97×5hrs× 2097
Installation examples
2930036 132 TEL0439805109 FAX0439805140 2128560 58016 TEL0445553820
FAX0445553828 4650025 2243 TEL0527694888 5320012 349 2F
TEL0668384188