+ All Categories
Home > Documents > m!ka briefing - · PDF fileBLK = 0 V YEL = +12­24VDC For WHITE light connect ... ­...

m!ka briefing - · PDF fileBLK = 0 V YEL = +12­24VDC For WHITE light connect ... ­...

Date post: 15-Mar-2018
Category:
Upload: doannguyet
View: 215 times
Download: 1 times
Share this document with a friend
48
m!ka briefing book
Transcript
Page 1: m!ka briefing -  · PDF fileBLK = 0 V YEL = +12­24VDC For WHITE light connect ... ­ You can deactivate the QuickFix function for security reasons. Turn in the screw next

1

m!kabriefing

book

Page 2: m!ka briefing -  · PDF fileBLK = 0 V YEL = +12­24VDC For WHITE light connect ... ­ You can deactivate the QuickFix function for security reasons. Turn in the screw next

2

Thank you for choosing Yellowtec products.

Enjoy m!ka, the most exciting support system for microphones and monitors. m!ka is robust, sleek and flexible.

All components are designed to fit with each other and can be combined in multiple ways. Check this Briefing Book to get initial infor­mation on how to install and adjust the system.

Please note: Safety instructions should be followed at all times!

Page 3: m!ka briefing -  · PDF fileBLK = 0 V YEL = +12­24VDC For WHITE light connect ... ­ You can deactivate the QuickFix function for security reasons. Turn in the screw next

3

Briefing Book Content

m!ka Mic Armm!ka Mic Arm TVm!ka Studiolight

m!ka MMS PDM Kitm!ka Power Sting

m!ka MMS Ceiling Mountm!ka Wall Mount

m!ka MMS Monitor Mountm!ka EasyLift

m!ka MMS Quick Fixm!ka MMS Cable Clamp

m!ka MMS Safety Stopm!ka Bushing

m!ka MMS Pole Adapterm!ka Table Clamp

m!ka Table Mountsm!ka Wall Mounts

m!ka Pad­Dockm!ka Copy Stand

Remarks

46 121617181920222426272930313234363840

Page 4: m!ka briefing -  · PDF fileBLK = 0 V YEL = +12­24VDC For WHITE light connect ... ­ You can deactivate the QuickFix function for security reasons. Turn in the screw next

4

m!ka Mic Arm „On Air“

RED = High

RED = High

Audio Shield

Audio Shield

BLU = Low

BLU = Low

Cut Off !N/C N/C

YEL = LED Indicator Remarks

5/8“

BLK = LED Indicator

For RED light connect BLK = 0 V YEL = +12­24VDC

For WHITE light connectBLK = +12­24VDC YEL = 0 V

or toggle polarity for dual use

Page 5: m!ka briefing -  · PDF fileBLK = 0 V YEL = +12­24VDC For WHITE light connect ... ­ You can deactivate the QuickFix function for security reasons. Turn in the screw next

5

RED = High

RED = High

Audio Shield

Audio Shield

BLU = Low

BLU = Low

m!ka Mic Arm

5/8“

Remarks

Page 6: m!ka briefing -  · PDF fileBLK = 0 V YEL = +12­24VDC For WHITE light connect ... ­ You can deactivate the QuickFix function for security reasons. Turn in the screw next

6

RED = High

Audio Shield

BLU = Low

m!ka Mic Arm TV „On Air“

BLK = LED Indicator

YEL = LED Indicator

Microphone

Page 7: m!ka briefing -  · PDF fileBLK = 0 V YEL = +12­24VDC For WHITE light connect ... ­ You can deactivate the QuickFix function for security reasons. Turn in the screw next

7

RED = HighAudio Shield

BLU = LowCut Off !

N/C

N/C

Remarks

m!ka Mic Arm TV „On Air“

For RED light connect BLK = 0 V YEL = +12­24VDC

For WHITE light connectBLK = +12­24VDC YEL = 0 V

or toggle polarity for dual use

Microphone

Page 8: m!ka briefing -  · PDF fileBLK = 0 V YEL = +12­24VDC For WHITE light connect ... ­ You can deactivate the QuickFix function for security reasons. Turn in the screw next

8

m!ka Mic Arm TV

RED = High

Audio ShieldBLU = Low

Microphone

Page 9: m!ka briefing -  · PDF fileBLK = 0 V YEL = +12­24VDC For WHITE light connect ... ­ You can deactivate the QuickFix function for security reasons. Turn in the screw next

9

m!ka Mic Arm TV

RED = HighAudio Shield

BLU = Low

Remarks

Microphone

Page 10: m!ka briefing -  · PDF fileBLK = 0 V YEL = +12­24VDC For WHITE light connect ... ­ You can deactivate the QuickFix function for security reasons. Turn in the screw next

10

Remarks

m!ka Mic Arm (all models)

Page 11: m!ka briefing -  · PDF fileBLK = 0 V YEL = +12­24VDC For WHITE light connect ... ­ You can deactivate the QuickFix function for security reasons. Turn in the screw next

11

m!ka Mic Arm (all models)

Remarks

Page 12: m!ka briefing -  · PDF fileBLK = 0 V YEL = +12­24VDC For WHITE light connect ... ­ You can deactivate the QuickFix function for security reasons. Turn in the screw next

12

Remarks

m!ka Studiolight

Page 13: m!ka briefing -  · PDF fileBLK = 0 V YEL = +12­24VDC For WHITE light connect ... ­ You can deactivate the QuickFix function for security reasons. Turn in the screw next

13

Remarks

m!ka Studiolight

Page 14: m!ka briefing -  · PDF fileBLK = 0 V YEL = +12­24VDC For WHITE light connect ... ­ You can deactivate the QuickFix function for security reasons. Turn in the screw next

14

1.

2.

Remarks

m!ka Studiolight

Page 15: m!ka briefing -  · PDF fileBLK = 0 V YEL = +12­24VDC For WHITE light connect ... ­ You can deactivate the QuickFix function for security reasons. Turn in the screw next

15

Remarks

m!ka Studiolight

Page 16: m!ka briefing -  · PDF fileBLK = 0 V YEL = +12­24VDC For WHITE light connect ... ­ You can deactivate the QuickFix function for security reasons. Turn in the screw next

16

Remarks

m!ka MMS PDM­Kit

C

Page 17: m!ka briefing -  · PDF fileBLK = 0 V YEL = +12­24VDC For WHITE light connect ... ­ You can deactivate the QuickFix function for security reasons. Turn in the screw next

17

Remarks

m!ka Power Sting

Page 18: m!ka briefing -  · PDF fileBLK = 0 V YEL = +12­24VDC For WHITE light connect ... ­ You can deactivate the QuickFix function for security reasons. Turn in the screw next

18

Remarks

m!ka MMS Ceiling Mount

Page 19: m!ka briefing -  · PDF fileBLK = 0 V YEL = +12­24VDC For WHITE light connect ... ­ You can deactivate the QuickFix function for security reasons. Turn in the screw next

19

Remarks

m!ka Wall Mount

Page 20: m!ka briefing -  · PDF fileBLK = 0 V YEL = +12­24VDC For WHITE light connect ... ­ You can deactivate the QuickFix function for security reasons. Turn in the screw next

20

3

4 Remarks

m!ka MMS Monitor Mount

Page 21: m!ka briefing -  · PDF fileBLK = 0 V YEL = +12­24VDC For WHITE light connect ... ­ You can deactivate the QuickFix function for security reasons. Turn in the screw next

21

Remarks

m!ka MMS Monitor Mount

Page 22: m!ka briefing -  · PDF fileBLK = 0 V YEL = +12­24VDC For WHITE light connect ... ­ You can deactivate the QuickFix function for security reasons. Turn in the screw next

22

m!ka EasyLift

Remarks

Page 23: m!ka briefing -  · PDF fileBLK = 0 V YEL = +12­24VDC For WHITE light connect ... ­ You can deactivate the QuickFix function for security reasons. Turn in the screw next

23

m!ka EasyLift

Remarks

Page 24: m!ka briefing -  · PDF fileBLK = 0 V YEL = +12­24VDC For WHITE light connect ... ­ You can deactivate the QuickFix function for security reasons. Turn in the screw next

24

m!ka MMS QuickFix

Remarks

Page 25: m!ka briefing -  · PDF fileBLK = 0 V YEL = +12­24VDC For WHITE light connect ... ­ You can deactivate the QuickFix function for security reasons. Turn in the screw next

25

Remarks

m!ka MMS QuickFix

Page 26: m!ka briefing -  · PDF fileBLK = 0 V YEL = +12­24VDC For WHITE light connect ... ­ You can deactivate the QuickFix function for security reasons. Turn in the screw next

26

Remarks

m!ka MMS Cable Clamp

Page 27: m!ka briefing -  · PDF fileBLK = 0 V YEL = +12­24VDC For WHITE light connect ... ­ You can deactivate the QuickFix function for security reasons. Turn in the screw next

27

STOP

Remarks

m!ka MMS Safety Stop

Page 28: m!ka briefing -  · PDF fileBLK = 0 V YEL = +12­24VDC For WHITE light connect ... ­ You can deactivate the QuickFix function for security reasons. Turn in the screw next

28

Remarks

m!ka MMS Monitor Arm (Friction)

Page 29: m!ka briefing -  · PDF fileBLK = 0 V YEL = +12­24VDC For WHITE light connect ... ­ You can deactivate the QuickFix function for security reasons. Turn in the screw next

29

Remarks

22 mm

m!ka Bushing

Page 30: m!ka briefing -  · PDF fileBLK = 0 V YEL = +12­24VDC For WHITE light connect ... ­ You can deactivate the QuickFix function for security reasons. Turn in the screw next

30

3

m!ka MMS Pole Adapter

Remarks

Page 31: m!ka briefing -  · PDF fileBLK = 0 V YEL = +12­24VDC For WHITE light connect ... ­ You can deactivate the QuickFix function for security reasons. Turn in the screw next

31

Remarks

m!ka Table Clamp

Page 32: m!ka briefing -  · PDF fileBLK = 0 V YEL = +12­24VDC For WHITE light connect ... ­ You can deactivate the QuickFix function for security reasons. Turn in the screw next

32

m!ka Table Through Mount

Page 33: m!ka briefing -  · PDF fileBLK = 0 V YEL = +12­24VDC For WHITE light connect ... ­ You can deactivate the QuickFix function for security reasons. Turn in the screw next

33

Remarks

m!ka Table Top Mount

Page 34: m!ka briefing -  · PDF fileBLK = 0 V YEL = +12­24VDC For WHITE light connect ... ­ You can deactivate the QuickFix function for security reasons. Turn in the screw next

34

Remarks

m!ka Wall Bracket

Page 35: m!ka briefing -  · PDF fileBLK = 0 V YEL = +12­24VDC For WHITE light connect ... ­ You can deactivate the QuickFix function for security reasons. Turn in the screw next

35

3

m!ka System Wall Adapter

Page 36: m!ka briefing -  · PDF fileBLK = 0 V YEL = +12­24VDC For WHITE light connect ... ­ You can deactivate the QuickFix function for security reasons. Turn in the screw next

36

Remarks

m!ka Pad­Dock

Page 37: m!ka briefing -  · PDF fileBLK = 0 V YEL = +12­24VDC For WHITE light connect ... ­ You can deactivate the QuickFix function for security reasons. Turn in the screw next

37

min 160mmmax 300mm

Remarks

m!ka Pad­Dock

Page 38: m!ka briefing -  · PDF fileBLK = 0 V YEL = +12­24VDC For WHITE light connect ... ­ You can deactivate the QuickFix function for security reasons. Turn in the screw next

38

m!ka Copy Stand

Remarks

Page 39: m!ka briefing -  · PDF fileBLK = 0 V YEL = +12­24VDC For WHITE light connect ... ­ You can deactivate the QuickFix function for security reasons. Turn in the screw next

39

Remarks

m!ka Copy Stand

Page 40: m!ka briefing -  · PDF fileBLK = 0 V YEL = +12­24VDC For WHITE light connect ... ­ You can deactivate the QuickFix function for security reasons. Turn in the screw next

40

Declaration of Conformity for m!ka Studiolight:

We declare under our sole responsibility that m!ka Studiolight meets the health and safety requirements of the EC Directive for General Product Safety.

The device complies with the following standards

•EN60589-1 •EN60589-2-4 •EN62031 •EN62471-2-1 •EN55015 •EN61547 •EN61000-3-2 •EN61000-3-3 •EN60589-1

according to the requirements of directives

•2006/95/EG •2004/108/EG

For YellowtecThum + Mahr GmbHHeinrich­Hertz­Str. 1­3D­40789 Monheim am Rhein

Monheim, 12.06.2015 Hanno Mahr, MD

m!ka Remarks

Page 41: m!ka briefing -  · PDF fileBLK = 0 V YEL = +12­24VDC For WHITE light connect ... ­ You can deactivate the QuickFix function for security reasons. Turn in the screw next

41

Page 4, 7­ We suggest using XLR­5 pin connectors for microphone signal and on air light feed on lower end of cable and XLR­3 type connectors for microphone on upper end of cable. ­ When installing the connector on upper end, cut off the black and yellow wires. They are not connected and do not carry any voltage.­ Always make sure to leave adequate cable lengths before you cut the cable to fit. It is not possible to install a new cable loom inside the arm.

Page 5, 9­ We suggest using XLR­3 type connectors on both ends of the loom.­ Always make sure to leave adequate cable lengths before you cut the cable to fit. It is not possible to install a new cable loom inside the arm.

Page 10­ Make sure the bolt at the bottom of your m!ka Mic Arm has its black plastic sleeve on. The sleeve is needed to fit the arm smoothly to the various mounting devices.­ Make sure that each mounting device has a yellow spacer installed.­ No yellow spacer will be needed when using the metal bushing.

Page 11­ You can adjust your m!ka Mic Arm to properly balance with the weight of your microphone. Follow two simple steps:­ Step 1: Do not pull the three knurled screws tight but keep them in a somewhat loose position. Identify the screw in the bottom of the m!ka Mic Arm and adjust it to have your microphone levitate when the arm is in an upright and 90 degree angled position. ­Step 2: Now fasten the knurled screws just enough to hold the microphone in the position wherever you pull it.

Page 42: m!ka briefing -  · PDF fileBLK = 0 V YEL = +12­24VDC For WHITE light connect ... ­ You can deactivate the QuickFix function for security reasons. Turn in the screw next

42

­ Do not pull the knurled screws too tight. They may break and the joints may squeak. Instead re­adjust the screw inside the bottom as in Step 1.­ If necessary, use Teflon spray in case of joint squeak.

Page 12­ Make sure the bolt at the bottom of your m!ka Studiolight has its black plastic sleeve on. The sleeve is needed to fit smoothly to the various mounting devices.­ Make sure that the mounting device has a yellow spacer installed.­ No yellow spacer will be needed when using the metal bushing.

Page 13­ Your m!ka Studiolight is prebalanced. Do not pull the knurled screws too tight. They may break and the joints may squeak. ­ Use Teflon spray in case of joint squeak.

Page 14Pay attention when connecting your m!ka Studiolight to mains voltage!­ Step 1: Always connect the low voltage connector prior to connecting to the mains.­ Step 2: Select the correct mains adapter for your country and clip it to the wall PSU.

Page 15Your m!ka Studiolight has an integrated DIM function.­ Press short for switching ON/OFF. ­ Press long to DIM up, press long again to DIM down. m!ka Studiolight will remember the last DIM value when switching it on again.

Page 16­ To secure proper upright mounting of the MMS pole we suggest drilling a minimum

m!ka Remarks

Page 43: m!ka briefing -  · PDF fileBLK = 0 V YEL = +12­24VDC For WHITE light connect ... ­ You can deactivate the QuickFix function for security reasons. Turn in the screw next

43

hole of 12mm diameter for the PDM Kit. ­ Use black or silver washer according to your choice, but always use one on both sides of the table top!­ If you need to use your own threaded bolt make sure you use M10 metric thread.­ The cable organizer clip will help to tidy your wiring.

Page 17­ Never use the Power Sting other than with the original m!ka Bushing. Table clamps are not suitable to hold an MMS arm. Use a gripper to fix the Power Sting.

Page 18­ When installing the m!ka Ceiling Mount it is your obligation to verify that your ceiling and your fasteners are suitable to hold the load.

Page 19­ When installing the m!ka Wall Mount it is your obligation to verify that your wall and your fasteners are suitable to hold the load.

Page 20­ Make sure you have checked the max. payload of your m!ka Monitor Arm. The information is printed on the product label on the rearside of the QuickFix.­ See Page 21 for how to secure a minimum headroom under your monitor.

Page 21­ In order to prevent unintended changes to the MMS height position simply remove the thumbscrews by pulling them out. Before you remove the screws make sure they are all properly tightend.

Page 44: m!ka briefing -  · PDF fileBLK = 0 V YEL = +12­24VDC For WHITE light connect ... ­ You can deactivate the QuickFix function for security reasons. Turn in the screw next

44

Page 22­ Use an Allen key to adjust EasyLift‘s pneumatic spring to your monitor‘s weight.­ Use the screwing devices at the rotating joints to adjust the joints.

Page 23­ You can deactivate the QuickFix function for security reasons. Turn in the screw next to the release lever in order to disengage its function.

Page 24­ The MMS QuickFix adapter is suitable to be used with VESA 75 and VESA 100 fixtures.­ Make sure that you use the correct screw size and length. Too long screws will damage your flat panel!

Page 25­ You can deactivate the QuickFix function for security reasons. Turn in the screw next to the release lever in order to disengage its function.

Page 26­ Insert the cable organizer clips into the bottom profile of the MMS Arm and turn it 90° to fix it.

Page 27­ To secure a minimum vertical position of your monitor insert the MMS Safety Stop Nut into the MMS pole. Use an Allen key and fasten it properly.

Page 28­ Use the Allen key of the thumbscrew for the height adjustment to de­ or increase the friction of the joints of your m!ka Monitor Arm

m!ka Remarks

Page 45: m!ka briefing -  · PDF fileBLK = 0 V YEL = +12­24VDC For WHITE light connect ... ­ You can deactivate the QuickFix function for security reasons. Turn in the screw next

45

Page 29­ To secure proper upright positioning of the m!ka Bushing drill a hole with a minimum diameter of 22 mm.­ The thread of the bushing is metric; should you ever need to replace the nut make sure you use the correct M20x1,5 thread.

Page 30­ Use an Allen key to fix the MMS Pole Adapter properly.­ Use a yellow spacer with the MMS Pole Adapter.

Page 31­ Never use the m!ka Table Clamp on curved surfaces ­ it may slip off!

Page 33­ You do not need to drill a central hole when you use a m!ka Table Top Mount. ­ Make sure you have suitable screws for the type of panel you install the base ring to.

Page 34­ When installing the m!ka Wall Bracket it is your obligation to verify that your wall and your fasteners are suitable to hold the load.­ Use a yellow spacer.

Page 36­ Make sure the m!ka Pad­Dock is properly oriented to support the tablet.­ In order to hold the tablet properly its size needs to be min 160mm and max 300mm.­ Tablets will fit at both landscape and upright orientation.

Page 46: m!ka briefing -  · PDF fileBLK = 0 V YEL = +12­24VDC For WHITE light connect ... ­ You can deactivate the QuickFix function for security reasons. Turn in the screw next

46

m!ka Remarks

Page 37­ An audible „click“ signals that the Pad­Dock is securely locked into position.

Page 38­ The cover panel for your m!ka Copy Stand holds and aligns by the integrated magnets.­ Make sure the magnets face each other.­ Follow cleaning instructions, never use detergents or alcohol.­ For daily care use micro fiber cloth supplied with Copy Stand.

Page 39­ You can deactivate the QuickFix function for security reasons. Turn in the screw next to the release lever in order to disengage its function.

Page 47: m!ka briefing -  · PDF fileBLK = 0 V YEL = +12­24VDC For WHITE light connect ... ­ You can deactivate the QuickFix function for security reasons. Turn in the screw next

47

Page 48: m!ka briefing -  · PDF fileBLK = 0 V YEL = +12­24VDC For WHITE light connect ... ­ You can deactivate the QuickFix function for security reasons. Turn in the screw next

48

yellowtec.com

m!ka­BB­V5.0


Recommended