20
8/12/2019 MobisysGateway 313 En http://slidepdf.com/reader/full/mobisysgateway-313-en 1/20  Version: 1.03 Date: 10/22/12  Mobisys GmbH Altrottstr. 26 D-69190 Walldorf www.mobisys.de  Documentation Mobisys Gateway 3.1.3
Transcript
Page 1: MobisysGateway 313 En

8/12/2019 MobisysGateway 313 En

http://slidepdf.com/reader/full/mobisysgateway-313-en 1/20

 

Version: 1.03 

Date: 10/22/12  

Mobisys GmbHAltrottstr. 26

D-69190 Walldorfwww.mobisys.de  

Documentation

Mobisys Gateway 3.1.3

Page 2: MobisysGateway 313 En

8/12/2019 MobisysGateway 313 En

http://slidepdf.com/reader/full/mobisysgateway-313-en 2/20

 

Date: 22 October 2012  Page 2 

Copyright

© Copyright 2012 Mobisys GmbH. All rights reserved.

No part of this brochure may be reproduced or transmitted in any form or for any purpose without theexpress permission of Mobisys GmbH. The information contained herein may be changed withoutprior notice.Mobisys GmbH further does not warrant the accuracy or completeness of the information, text, graphics,links, or other items contained within these materials. Mobisys GmbH shall not be liable for any special,indirect, incidental, or consequential damages, including without limitation, lost revenues or lost profits,which may result from the use of these materials. The information in this documentation is subject tochange without notice and does not represent a commitment on the part of Mobisys GmbH for the future.Some software products marketed by Mobisys GmbH and its distributors contain proprietary softwarecomponents of other software vendors.

Microsoft®, WINDOWS®, NT®, EXCEL® and SQL-Server® are registered trademarks of MicrosoftCorporation.IBM®, DB2®, OS/2®, DB2/6000®, Parallel Sysplex®, MVS/ESA®, RS/6000®, AIX®, S/390®, AS/400®,OS/390®, and OS/400® are registered trademarks of IBM Corporation.OSF/Motif® is a registered trademark of Open Software Foundation.ORACLE® is a registered trademark of ORACLE Corporation, California, USA.INFORMIX®-OnLine for SAP is a registered trademark of Informix Software Incorporated.UNIX® and X/Open® are registered trademarks of SCO Santa Cruz Operation.

 ADABAS® is a registered trademark of Software AG.SAP®, R/2®, R/3®, RIVA®, ABAP/4®, SAP ArchiveLink®, SAPaccess®, SAPmail®, SAPoffice®,

SAP-EDI®, R/3 Retail®, SAP EarlyWatch®, SAP Business Workflow®, ALE/WEB, Team SAP,

BAPI, Management Cockpit are registered or unregistered trademarks of SAP AG, Walldorf, Ger-many.

Page 3: MobisysGateway 313 En

8/12/2019 MobisysGateway 313 En

http://slidepdf.com/reader/full/mobisysgateway-313-en 3/20

 

Date: 22 October 2012  Page 3 

Release Info:

Release Date ID Description

1.00 02.13.2009 TS Document created

1.01 06.10.2010 TS Change for version 3.0.9

1.02 07.15.2010 MB Adjustment for version 3.1.2

1.03 05.05.2011 TS Adjustment for version 3.1.3

Page 4: MobisysGateway 313 En

8/12/2019 MobisysGateway 313 En

http://slidepdf.com/reader/full/mobisysgateway-313-en 4/20

 

Date: 22 October 2012  Page 4 

Table of contents 

Copyright ............................................................................................................. 2 1  Introduction .................................................................................................................... 5 2  Description of Interface................................................................................................... 6 

2.1  Overview ................................................................................................................. 6 2.1.1  Notes ............................................................................................................... 6 

2.2  Create New Connection .......................................................................................... 7 2.2.1  Receiver ........................................................................................................... 7 

2.2.1.1  TCP/IP receiver ......................................................................................... 8 2.2.1.2  HTTP receiver ........................................................................................... 9 2.2.1.3  3964R receiver .........................................................................................10 

2.2.2  Manipulator .....................................................................................................11 2.2.2.1  PrefixPostfix manipulator ..........................................................................11 

2.2.3  Sender ............................................................................................................12 2.2.3.1  TCP/IP sender..........................................................................................12 2.2.3.2  HTTP sender ............................................................................................13 2.2.3.3  3964R sender ..........................................................................................13 2.2.3.4  Serial sender ............................................................................................14 

2.2.4  Logging (receiver + sender) ............................................................................15 2.3  Process connection ................................................................................................16 2.4  Event log ................................................................................................................17 

2.4.1  Settings ...........................................................................................................18 2.4.2  Export events ..................................................................................................19 

3  Notes .............................................................................................................................20 

Page 5: MobisysGateway 313 En

8/12/2019 MobisysGateway 313 En

http://slidepdf.com/reader/full/mobisysgateway-313-en 5/20

 

Date: 22 October 2012  Page 5 

1 Introduction

The Mobisys Gateway serves to forward data of any kind from different source types to var-

ious destination types.It supports both different logs (HTTP, TCP/IP, 3964R) anddifferent interfaces (COM, Ethernet).

Page 6: MobisysGateway 313 En

8/12/2019 MobisysGateway 313 En

http://slidepdf.com/reader/full/mobisysgateway-313-en 6/20

 

Date: 22 October 2012  Page 6 

2 Description of Interface

2.1 Overview

In the overview, you see connections that have already been created and their status(whether they are activated or deactivated).

 A connection can be selected either by mouse-click or by using the arrow keys.

New …: Create new connection (key combination: [ALT] + [N] )Edit …: Edit selected connection (key combination: [F2] or [ALT] + [E] )Delete: Delete selected connection (key combination: [DEL] or [ALT] + [D] )Activate: Activate or deactivate selected connection (key combination: [space] or  

[ALT] + [A] )Start service: Starts the Mobisys Gateway serviceStop service: Stops the Mobisys Gateway serviceEvent log…: The Windows event display is opened

2.1.1 Notes

If connections have been created or processed, these are not used by Mobisys Gatewayuntil after the service has been restarted. To do this, click the Start servicebutton. If the service is already running, you must first click the Stop service button. 

Page 7: MobisysGateway 313 En

8/12/2019 MobisysGateway 313 En

http://slidepdf.com/reader/full/mobisysgateway-313-en 7/20

 

Date: 22 October 2012  Page 7 

2.2 Create New Connection

To create a new connection, click New … (or use the key combination: [ALT] + [N] ).You can select any name for the new connection, which is shown in the overview. After this, the receiver, manipulator, and sender must be selected and configured.These are described in the following.

2.2.1 Receiver

When you select a receiver (or click on config…), the relevantconfiguration window opens.

Page 8: MobisysGateway 313 En

8/12/2019 MobisysGateway 313 En

http://slidepdf.com/reader/full/mobisysgateway-313-en 8/20

 

Date: 22 October 2012  Page 8 

2.2.1.1 TCP/IP receiver

Port: The data is received at this port

Timeout: Specification of duration in milliseconds in which attempts are made to read furtherdata following the arrival of the first data.Close connection after send failure: If you activate this, the connection is closed in theevent that it is not possible to reach the destination.STX: Start characters as hex input as of which the data transmitted is collected.ETX: End characters as hex input as of which no further data is collected.

Note: The character codes STX and ETX are passed on together with transaction data to thesender that has been set.If STX and ETX are to be filtered, this must be configured in the manipulator.

White list: If the list does not contain any entries, data is accepted from each device thatconnects up. If data is to be accepted from certain devices only, you can enter the IP of eachrelevant device here. All other connection attempts are then rejected.

Page 9: MobisysGateway 313 En

8/12/2019 MobisysGateway 313 En

http://slidepdf.com/reader/full/mobisysgateway-313-en 9/20

 

Date: 22 October 2012  Page 9 

2.2.1.2 HTTP receiv er

Port: The data is received at this portSSL: Here you specify whether an encryption log is to be used for the secure sockets layer(SSL) to ensure the secure transfer of data. By setting thisindicator, you activate SSL encryption.White list: If the list does not contain any entries, data is accepted from each device thatconnects up. If data is to be accepted from certain devices only, you can enter the IP of eachrelevant device here. All other connection attempts are then rejected.

Page 10: MobisysGateway 313 En

8/12/2019 MobisysGateway 313 En

http://slidepdf.com/reader/full/mobisysgateway-313-en 10/20

 

Date: 22 October 2012  Page 10 

2.2.1.3 3964R receiver

COM port: Select the name of the COM port that is to be usedBaud rate: Set the correct Baud rate (bits per second)Parity: Select the parityStopBits: Select the number of stop bitsDataBits: Select the number of data bitsChecksum: If you activate this, the check sum is sent and checked.

(with check sum = 3964, without check sum = 3964R)

The settings you select must be suitablefor the hardware. Please refer to the doc-umentation for the hardware in this re-spect.

Page 11: MobisysGateway 313 En

8/12/2019 MobisysGateway 313 En

http://slidepdf.com/reader/full/mobisysgateway-313-en 11/20

 

Date: 22 October 2012  Page 11 

2.2.2 Manipulator

When you select a manipulator (or click config…) the appropriate

configuration window opens.

2.2.2.1 PrefixPostf ix manip ulator

Via Add to Request and Remove from Request, you can add start and end charactercodes to a request received by the receiver - or remove them from the request - before thelatter is forwarded to the sender.The same applies to the response. The start and end code can be added to or removed fromthis using Add to Response and Remove from Response .

STX: Hex input that is to be added to or removed from the request or response.ETX: Hex input that is to be added to or removed from the request or response.

Page 12: MobisysGateway 313 En

8/12/2019 MobisysGateway 313 En

http://slidepdf.com/reader/full/mobisysgateway-313-en 12/20

 

Date: 22 October 2012  Page 12 

2.2.3 Sender

When you select a sender (or click on config…), the relevant

configuration window opens.

2.2.3.1 TCP/IP sen der

IP: The data is sent to this IP.Port: The IP is to be available at this port as server.Connect timeout: Specification of duration in milliseconds in which attempts are made to

reach the IP.Receive timeout: Specification of a duration in milliseconds in which a response is awaitedfrom the IP.STX: Start characters as hex input as of which the data transmitted is collected.ETX: End characters as hex input as of which no further data is collected.

Page 13: MobisysGateway 313 En

8/12/2019 MobisysGateway 313 En

http://slidepdf.com/reader/full/mobisysgateway-313-en 13/20

 

Date: 22 October 2012  Page 13 

2.2.3.2 HTTP sender

IP: The data is sent to this IP.Port: The IP is to be available at this port as server.Service: If an SAP system is defined under IP:Port, here you can enter a service.This must be set up in the SAP system.Timeout: Specification of duration in milliseconds in which attempts are made to reach theIP.SSL: Here you specify whether an encryption log is to be used for the secure sockets layer(SSL) to ensure the secure transfer of data. By setting thisindicator, you activate SSL encryption.

2.2.3.3 3964R sen der

COM port: Select the name of the COM port that is to be usedBaud rate: Set the correct Baud rate (bits per second)Parity: Select the parityStopBits: Select the number of stop bitsDataBits: Select the number of data bitsChecksum: If you activate this, the check sum is sent and checked.

(with check sum = 3964, without check sum = 3964R)

The settings you select must be suitablefor the hardware. Please refer to the doc-umentation for the hardware in this re-

spect.

Page 14: MobisysGateway 313 En

8/12/2019 MobisysGateway 313 En

http://slidepdf.com/reader/full/mobisysgateway-313-en 14/20

 

Date: 22 October 2012  Page 14 

2.2.3.4 Serial send er

COM port: Select the name of the COM port that is to be usedBaud rate: Set the correct Baud rate (bits per second)Parity: Select the parityStopBits: Select the number of stop bitsDataBits: Select the number of data bitsTimeout: Duration in milliseconds awaited until the response is read.ACK/NAK: Check for ACK/NAK. If NAK is sent, an attempt is made to resend the request.

(See Retries) Retries: Number of attempts if NAK was read as response.Raw response: If checked, the data is returned as delivered by the hardware. Otherwise, ACK, NAK, ETB, SI, SO, and EOT are returned as text.

Page 15: MobisysGateway 313 En

8/12/2019 MobisysGateway 313 En

http://slidepdf.com/reader/full/mobisysgateway-313-en 15/20

 

Date: 22 October 2012  Page 15 

2.2.4 Logging (receiver + sender)

You can activate a logging function for each receiver and sender. In the process, eachdata record that is sent and received is individually logged in a file.The file name has the following structure:R_127_0_0_1_5000_20090212103243839

R or S = Receiver or sender127_0_0_1 = IP5000/6000 = Port20090212 = Year, month, day103243839 = Hours (XX), minutes (XX), seconds (XX), milliseconds (XXX)

Log received data: Activate loggingLifetime: Duration in hours in which the files remain stored. Older files are automatically de-leted.Select location…: Select destination directory

 After the selection and configuration of the receiver, manipulator, and sender, the newconnection can be stored by clicking Save and then appears in the overview:

Page 16: MobisysGateway 313 En

8/12/2019 MobisysGateway 313 En

http://slidepdf.com/reader/full/mobisysgateway-313-en 16/20

 

Date: 22 October 2012  Page 16 

2.3 Process connection

When you click Edit … (or use the Key combination: [F2] or [ALT] + [E] ), you canprocess an existing connection.In the process, the same configuration screens are used as for the creation of a newconnection. Refer to Chapter 2.2 for the relevant possible settings.

Page 17: MobisysGateway 313 En

8/12/2019 MobisysGateway 313 En

http://slidepdf.com/reader/full/mobisysgateway-313-en 17/20

 

Date: 22 October 2012  Page 17 

2.4 Event log

If you click Event log… in the configurator, the Windows event display opens, in which theactions are logged by the Mobisys Gateway.

Page 18: MobisysGateway 313 En

8/12/2019 MobisysGateway 313 En

http://slidepdf.com/reader/full/mobisysgateway-313-en 18/20

 

Date: 22 October 2012  Page 18 

2.4.1 Settings

You can call up the settings via right-click/Property on MobisysGateway.

Here Overwrite events if necessary must be selected so thatnew events will continue to be logged if the maximum log size is exceeded.

The maximum log size can be changed as required.

Page 19: MobisysGateway 313 En

8/12/2019 MobisysGateway 313 En

http://slidepdf.com/reader/full/mobisysgateway-313-en 19/20

 

Date: 22 October 2012  Page 19 

2.4.2 Export events

Via right-click/Save log file under…, you can save the log file as*.evt.

Via right-click/Export list…, you can save the log file as *.txt(among other options).

Page 20: MobisysGateway 313 En

8/12/2019 MobisysGateway 313 En

http://slidepdf.com/reader/full/mobisysgateway-313-en 20/20

 

3 Notes