+ All Categories
Home > Documents > Mod08 Amos

Mod08 Amos

Date post: 27-Oct-2015
Category:
Upload: marcelo-maciel
View: 278 times
Download: 41 times
Share this document with a friend
Popular Tags:
90
EN4401EN00EN_0014 © Siemens Enterprise Communications GmbH & Co. KG 2011. All rights reserved. Siemens Enterprise Communications GmbH & Co. KG is a trademark licensee of Siemens AG 1 AMOs Siemens AMOs Contents 1 Administration and Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 1.1 Types of AMOs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 1.2 Loading operational tasks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 1.3 AMO Syntax. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 1.3.1 Structure of a command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 1.3.2 The parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 2 Syntax for AMO Input . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 2.1 Example of AMO Input. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 2.2 Selecting Important Verbs and Nouns . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 3 Protection of software features (codeword) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 3.1 Feature description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 3.2 Codeword variants . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 3.3 Codew description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 3.4 Service information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 3.5 Generation (example) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 3.6 HiPath 4000 V6 Licensing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 3.7 License Management in the HiPath 4000 Assistant V6 . . . . . . . . . . . . . . . . . . . . . . . . 24 3.8 Relevant AMO . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27 4 AMOs in the User Area . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29 5 WABE - Digit Analysis . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31 5.1 Structure of the DPLN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31 5.2 Overview DARs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32 5.3 Overview of the CPS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43
Transcript
Page 1: Mod08 Amos

AMOs Siemens

AMOs

Contents1 Administration and Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31.1 Types of AMOs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31.2 Loading operational tasks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41.3 AMO Syntax. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5

1.3.1 Structure of a command. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51.3.2 The parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6

2 Syntax for AMO Input . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 72.1 Example of AMO Input. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 82.2 Selecting Important Verbs and Nouns . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9

3 Protection of software features (codeword) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 113.1 Feature description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 113.2 Codeword variants. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 133.3 Codew description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 153.4 Service information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 163.5 Generation (example) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 173.6 HiPath 4000 V6 Licensing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 223.7 License Management in the HiPath 4000 Assistant V6. . . . . . . . . . . . . . . . . . . . . . . . 243.8 Relevant AMO . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27

4 AMOs in the User Area . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29

5 WABE - Digit Analysis . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 315.1 Structure of the DPLN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 315.2 Overview DARs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 325.3 Overview of the CPS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43

EN4401EN00EN_0014© Siemens Enterprise Communications GmbH & Co. KG 2011. All rights reserved.Siemens Enterprise Communications GmbH & Co. KG is a trademark licensee of Siemens AG

1

Page 2: Mod08 Amos

2

AMOsSiemens

6 VBZ - Internal Traffic Restrictions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47

7 COSSU - Classes of Service . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49

8 TAPRO - Key Programming . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55

9 SBCSU - Station and S0 Bus Configuration of SWU. . . . . . . . . . . . . . . . . . . . . . . 59

10 SCSU - Subscriber Configuration of Switching Unit . . . . . . . . . . . . . . . . . . . . . . . 63

11 Configuration of a Subscriber . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6511.1 UP0/E - subscriber . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6511.2 Configuration of an IP subscriber . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6911.3 Deletion of a Subscriber . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 70

12 SDAT - Administration of Individual Subscriber Attributes and General Subscriber Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 71

12.1 CHANGE-SDAT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7112.1.1 Changing Attributes / Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7112.1.2 Changing General Subscriber Data (Branch DATA). . . . . . . . . . . . . . . . . . . 7112.1.3 Changing Subscriber Data (Branch DATA1). . . . . . . . . . . . . . . . . . . . . . . . . 71

12.2 DELETE-SDAT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7212.3 DISPLAY-SDAT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7212.4 REGENERATE-SDAT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 72

13 BERUM - Class of Service Switchover . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 73

14 BERUZ - Times at which Class of Service Switchover is to Occur . . . . . . . . . . . 75

15 ZIEL - Destination Addresses for Stations. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7715.1 ADD-ZIEL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8015.2 DISPLAY-ZIEL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8015.3 REGENERATE-ZIEL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 80

16 ACTDA - Activation of User Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 81

17 PERSI - Personal Identification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 83

18 LRNGZ - List of Central Speed Dialing Numbers. . . . . . . . . . . . . . . . . . . . . . . . . . 85

19 ZRNGZ - Central Speed Calling Digit Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 87

EN4401EN00EN_0014© Siemens Enterprise Communications GmbH & Co. KG 2011. All rights reserved.

Siemens Enterprise Communications GmbH & Co. KG is a trademark licensee of Siemens AG

Page 3: Mod08 Amos

AMOs Siemens

1 Administration and Maintenance

1.1 Types of AMOs

TYPES of AMOs

ADMINISTRATION

MAINTENANCE

SYSTEM

REMOTE ADMIN. & MAINTENANCE

(TELE-SERVICE)

- Configuration of system peripherals

- Administration of features

- Administration of call charge registration parameters

- Initialization of traffic metering

- Trace and diagnostic evaluation (Debugger)- Blocking/unblocking of system units- Checking of system units

- Data file administration

- Access authorizations (passwords)

- Disk processing (CT, MT, HD)

- Memory update

- Date and time

- Database generation

- Documentation

- Transfer of fault messages

- Starting of AMOs

EN4401EN00EN_0014© Siemens Enterprise Communications GmbH & Co. KG 2011. All rights reserved.Siemens Enterprise Communications GmbH & Co. KG is a trademark licensee of Siemens AG

3

Page 4: Mod08 Amos

4

AMOsSiemens

1.2 Loading operational tasks

ADS Administration and Data Server HD Hard DiskAMC Administration and Maintenance

ControlI/O Input/Output

AMO Administration, Maintenance and Organization

LDU Logical Device Unit

BTT Operating Terminal MMI Man Machine Interpreter

SWU or CC

ADP

HD

SubsystemTables

SubsystemProgram

AMO y

AMO z

Overlay

AMC

Polycom CMA Desktop for Apple

zy

AMO x

Program

Polycom CMA Desktop for Apple

AMC

MMI LDU

OS free memory

zy

AMOx

Tables

I / O

Data

D

B

A

R

AMO x

PC

LAN or V24Asy IDE/SCSI

EN4401EN00EN_0014© Siemens Enterprise Communications GmbH & Co. KG 2011. All rights reserved.

Siemens Enterprise Communications GmbH & Co. KG is a trademark licensee of Siemens AG

Page 5: Mod08 Amos

AMOs Siemens

1.3 AMO Syntax

The AMO (Administration, Maintenance and Organization) stands for administration and main-tenance tasks that are needed for setting up, managing, troubleshooting, maintaining and com-missioning the HiPath 4000 system.

It is primarily a script language that is checked for correct syntax by the system. Tips are stored to provide the user with helpful information.

Syntactically incorrect entries are rejected by the system and the AMO enters a so-called prompt status. It requests entry of the correct values.

Syntactically correct but functionally incorrect entries are not queried.

Thus, for example, all executive-secretary groups can be accidentally deleted by an uninten-tional command.

1.3.1 Structure of a command

> An AMO never asks whether you really want to delete everything.

VERBADDCHANGEDISPLAYSTARTSTOP

USW.

NOUN:SBCSU:PERSI:DATE:COPY:GEZAB:

USW.

The VERB, or the action that is to be executed, is separated from the command, the NOUN, by a minus sign.

Between the invocation and the following parameters, acolon is used as a separator from the parameters.

The NOUN can also be entered ina short format.

EN4401EN00EN_0014© Siemens Enterprise Communications GmbH & Co. KG 2011. All rights reserved.Siemens Enterprise Communications GmbH & Co. KG is a trademark licensee of Siemens AG

5

Page 6: Mod08 Amos

6

AMOsSiemens

1.3.2 The parameters

After the invocation command, the necessary parameters are entered.

Parameters can be numerical and alphanumerical values.

To set up a subscriber, you require the SBCSU command (Subscriber Bus Configuration Switching Unit) and the SETUP verb..

ADD-SBCSU:STNO=4711&4713&&4719,OPT=OPTI,PEN=1-1-25-12;,....................;

One option for administration is the keyword-oriented entry. The parameter(s) are named and entered, which can also result in chains linked with a "§".

Parameter&Parameter&& Parameter,

If you would like to set up the same devices multiple times, you can also create the link with "&&", in which case the execution is from value to value. Up to ten links are possible.

The individual parameters are separated by a comma.

In addition to the keyword-oriented entry, a position-oriented entry is also possible. In this case, you need to know the position of the parameters and comment out those that are not re-quired. A mixture of both parameter entry types is not possible.

ADD-SBCSU:4711&4713&&4719,OPTI,1-1-25-12;,,,,,,,,,,,;

A semicolon is always placed at the end of an entry. This is performed automatically by the sys-tem when the AMO is run through but can also take place during entry if no other entries are needed. If parameters are still missing after all, the AMO outputs a query. You can enter a "?" or "??" for each query. You are then given a tip.

Mandatory parameters

Selectable mandatory

Freely selectable pa-rameters

Parameters that the AMO needs in order to fulfill its function and that cannot be replaced by its own values. One example is the station number of a subscriber.

Parameters that must be set but that can be supple-mented through default values or own search en-tries.

Parameters that have optional functions.These are generally not entered.

EN4401EN00EN_0014© Siemens Enterprise Communications GmbH & Co. KG 2011. All rights reserved.

Siemens Enterprise Communications GmbH & Co. KG is a trademark licensee of Siemens AG

Page 7: Mod08 Amos

AMOs Siemens

2 Syntax for AMO Input

COMMAND CODE: PARAMETER, PARAMETER ....;

ACTIVITY - FUNCTIONS PARAMETER NAME =PARAMETER VALUEVERB - NOUN orADD - AUN POSITION-DEPENDENT PARAMETER (VALUE)

( ) EXPLANATORY TEXT PASSAGES[ ] PARAMETER NAME and PARAMETER VALUE may be entered.< > Name of PARAMETER VALUE, all possible values are explained

separately..{ } Entry of at least one PARAMETER, rest optional: Separating COMMAND CODE and PARAMETER- Separating ACTIVITY and FUNCTIONS OF THE COMMAND CODE; END of AMO INPUT

PARAMETER NAME = PARAMETER VALUE

One of the given PARAMETER VALUES must be assigned to the PARAMETER NAME.

PARAMETER NAME = <PARAMETER VALUE>

An individual value, a string of individual values, or a group of individual values must be allocated to the PARAMETER NAME.

[PARAMETER NAME = <PARAMETER VALUE>]

Optional input of PARAMETER NAME, PARAMETER VALUE.

& & STRING of INDIVIDUAL VALUES && GROUP of INDIVIDUAL VALUESI OR GATING - one of the given parameters is entered up to the semicolon as

an alternative.

<number> PARAMETER consists of DECIMAL NUMBER(S)<param> PARAMETER VALUE consists of LETTERS A...Z, DIGITS 0...9<string> PARAMETER VALUE consists of CHARACTERS (all except ', ”)<key-num> PARAMETER VALUE consists of CHARACTERS 0...9, A...D, *, #<a-b-c...> PARAMETER VALUE consists of PARAMETER ARGUMENTS<identifier> PARAMETER VALUE consists of CHARACTERS (A...Z, 0...9)

1. character is a letter

<name> = <param>

EN4401EN00EN_0014© Siemens Enterprise Communications GmbH & Co. KG 2011. All rights reserved.Siemens Enterprise Communications GmbH & Co. KG is a trademark licensee of Siemens AG

7

Page 8: Mod08 Amos

8

AMOsSiemens

2.1 Example of AMO Input

Procedure Overview

Procedure Overview

Command Code Parameter

DISPLAY-PERSI TYPE =SYS;I TYPE = COPIN, [COPIN=<number>] ;I TYPE = MODULO ;I TYPE = NAME, [STNO=<number>] ;I TYPE = PIN, [PIN=<string>] ,[PINTYPE=<number>] ;I TYPE = STN, [STNO=<number>], PINTYPE=<string>] ;I TYPE = CCMS, [CCMSCD=<keynum>],[DPLN=<number>],[STNO=<number>] ;

Command Code Parameter

DISPLAY-SCSU [STNO]=<number>,e.g.ITYPE =COS, COSNO=<number>;

EN4401EN00EN_0014© Siemens Enterprise Communications GmbH & Co. KG 2011. All rights reserved.

Siemens Enterprise Communications GmbH & Co. KG is a trademark licensee of Siemens AG

Page 9: Mod08 Amos

AMOs Siemens

2.2 Selecting Important Verbs and Nouns

The maximum number of inputs for the AMO for the verb (action)

VERB - NOUN

ADD - PERSICHAnge - PERSIDISplay - PERSIDELete - PERSIREGenerate - PERSITest - APSCopy - APSEXEC - UPDATSTArt - INFOSTOP - BELINDUMP - APSCOLLECT - SELSACTivate - DSSUDEACTivate - DSSUSWITCH - DSSM

● AMO - code explained in the BCSU example

B

B board

S subscriberL lineU unitD deviceC cabinetT trunkA attendant

C

C configuration(console)

S switch/subscriberD display

S U

SU switching unitSM server moduleVM voicemail module

EN4401EN00EN_0014© Siemens Enterprise Communications GmbH & Co. KG 2011. All rights reserved.Siemens Enterprise Communications GmbH & Co. KG is a trademark licensee of Siemens AG

9

Page 10: Mod08 Amos

10

AMOsSiemens

EN4401EN00EN_0014© Siemens Enterprise Communications GmbH & Co. KG 2011. All rights reserved.

Siemens Enterprise Communications GmbH & Co. KG is a trademark licensee of Siemens AG

Page 11: Mod08 Amos

AMOs Siemens

3 Protection of software features (codeword)

3.1 Feature description

Features are sold in feature packages. Each package is allocated a marketing value. The fea-ture quantities purchased by a customer are encrypted as an alphanumeric "codeword".The new hardware, HiPath 4000 V2, features a SIM card on the DSCXL board (ADP). The don-gle used for existing hardware is upwards compatible. However, if the system is upgraded to Hipath 4000 V2.0 then a new codeword has to be installed.

New hardware: Old hardware:

The dongle or the SIM card and the codeword "tell" the system which feature packages and quantities were purchased by the customer. When the system is configured, a special plausi-bility check is used to ensure that the configuration data corresponds to the purchased features and quantities.

SIM card on the DSCXL board (ADP) Dongle for existing systems

EN4401EN00EN_0014© Siemens Enterprise Communications GmbH & Co. KG 2011. All rights reserved.Siemens Enterprise Communications GmbH & Co. KG is a trademark licensee of Siemens AG

11

Page 12: Mod08 Amos

12

AMOsSiemens

ComScendo CC-AP for AP Emergency

PNE

Voice com-pression IP Entry Agent

Protection of software features

Remote Survivability Cordless E

CODEWORD

EN4401EN00EN_0014© Siemens Enterprise Communications GmbH & Co. KG 2011. All rights reserved.

Siemens Enterprise Communications GmbH & Co. KG is a trademark licensee of Siemens AG

Page 13: Mod08 Amos

AMOs Siemens

3.2 Codeword variants

In HiPath 4000 V2.0 and later, the CODEWORD will feature four variants:

1. Normal mode:This is the approved operating mode as implemented in HiPath 1.0. In normal mode, a codeword and licenses are requested for all relevant licenses in the database.

2. Trial mode:This feature introduces a time-limited trial mode. When you activate trial mode, you can skip the license restrictions that are temporarily displayed. During this time, the AMOs work as if unrestricted licenses were available except that an advisory message is sent to the users if license restriction violations occur.

3. Emergency mode: The system activates the Emergency mode, in case of special situations. Special situations are:Validity of the Codeword is expired;Dongle resp. SIM card is missing;Codeword is missing;Dongle resp. SIM card does not match to Codeword;In the Emergency mode the AMO execution is blocked in the SWU. The only AMOs that can be executed are the AMO CODEW / DATE.

4. Escalated Emergency mode:The feature triggers an additional system operation restriction (it blocks the FEASU fea-ture) when the system is in escalation mode for an extended period of time. This restriction is known as escalation of the Emergency mode.

EN4401EN00EN_0014© Siemens Enterprise Communications GmbH & Co. KG 2011. All rights reserved.Siemens Enterprise Communications GmbH & Co. KG is a trademark licensee of Siemens AG

13

Page 14: Mod08 Amos

14

AMOsSiemens

CODEW variants with dongle in HiPath 4000 at V2.0

● In a network the network codeword from the Hipath 4000 Manager (LMT) is used. The original Codeword must be added previously in the system. The Network codeword then overwrites the Codeword on a daily basis. If this does not hap-pen then a 60 day test mode begins.

● The 30 Day Service-Dongle will no longer be given in Hipath4000 V2.0.

● The creation date is coded in the Codeword and is stored in the database, when the Code-word is added in the system. The possibility to add an older Codeword is blocked in this way.

TYPE Description Dongle Sim Card

TYPE 1 (Customer) standard: 2 x Test mode each for 30 days(then a new Codeword is required)

X X

TYPE 2 (Special) Via LMT (Licence Management Tool) with a time limit of 60 days or an agreed time limit

X X

Via LMT (Licence Management Tool) without a time limit

X X

EN4401EN00EN_0014© Siemens Enterprise Communications GmbH & Co. KG 2011. All rights reserved.

Siemens Enterprise Communications GmbH & Co. KG is a trademark licensee of Siemens AG

Page 15: Mod08 Amos

AMOs Siemens

3.3 Codew description

Unit Description AMOs Parameter

COMSCENDO Counting/marketingper configured B channel/ana-log channel to:

– station (optiset = 1 B chan-nel; optiset E or optiPoint 500... with adapter = 2 B chan-nels; optiip = 1 B channel, butmax. 2 B channels per Up0E)or attendant console

ACSU ACTYPE=AC4/ACW2Q/ACW-MQ

BCSU TYPE=SIGNOFF

RCSU RECAPL=ACDR/ACDMUS/HMUSIC

SBCSU DVCFIG=ANAFAX/ANADTE/ANADEV/FAX/DTE/OPTIP500/OP-TISET/S0PP/S2PP/SET600/OPTIIP

SCSU DVCFIG=ANATE/ANATECM/AUXDIGI

SSC TYPE=GENANS/MSGR/EX-TANN/CC/VMXMWI

SBCSU ART=OPTIERW

– Trunk or tie(including ATM Networking)

TACSU DEVTYPE=TC/TC1/TC2/NW/TT/TT1/TT2/TT3/TT4

TDCSU DEV=S0COD/S0CONN/S1COD/S1CONN/S1PVC/S1SVC/LAN/S1PVCCO/S2COD/S2CONN/S2PVC/S2SVC/S2PVCCO/VCCOD/VCCONN/HG3550/CDG-CONN/CDGCOD/30/ATMS-VC/ATMPVC3/ATMPVC7/ATMPVC15/ATMPVC23/ATMPVC2X/ATMPVC30/ATMPVCCO

TSCSU DEV=CC/CCM/ANS/RA/RAS/DICT/SPKR/DOOR

CORDLESS E Counting/marketing of the acti-vation license per B channel (for example SLC16 to base station) irrespective of the operating software

SBCSU DVCFIG=BASE

EN4401EN00EN_0014© Siemens Enterprise Communications GmbH & Co. KG 2011. All rights reserved.Siemens Enterprise Communications GmbH & Co. KG is a trademark licensee of Siemens AG

15

Page 16: Mod08 Amos

16

AMOsSiemens

3.4 Service information

● The counters bear no relationship to the feature dimensioning values administered with the AMO DIMSU.

● For the purposes of software feature protection, "ComScendo" is the equivalent of "station" for the following components:

– Optiset E

– optiPoint 500 / optiPoint 400 / optiPoint 410

– ANATE

– ANATECM

– AUXDIGI

– Signed off TSI instead of signed off station

– PP (all S0/S2)

– FBUS (all call numbers)

● The dongle or the SIM card is immediately activated on startup.

● The validity of a codeword may be limited to a specific period. It is calculated in days from the creation date.

PNE Counting/marketing per VPN B channel configured from/to the board with PNEDIUS2 line type (use the AMO BGDAT to check the line type of a board)

TDCSU DEV=S2CONN

HIPATH PRO-CENTER ENTRY AGENT

Counting/marketing per active (logged in) agent

AGENT AGTID=<number>

HIPATH AP REMOTE SURVIVABILITY

Counting the IPDA survivability remote shelves for connections over ISDN (ID9206)(AMO SIPCO parameter SURV-NET)

APRT CONF=ROUTER/AP

CC-AP FORAP EMERGEN-CY

Counting/marketing per CC con-figured for AP Emergency

APESU DATA=CCAP

Unit Description AMOs Parameter

EN4401EN00EN_0014© Siemens Enterprise Communications GmbH & Co. KG 2011. All rights reserved.

Siemens Enterprise Communications GmbH & Co. KG is a trademark licensee of Siemens AG

Page 17: Mod08 Amos

AMOs Siemens

● The expiry date is shown after each LOGON command or after the initial ADD command. You can also check the date with the DISPLAY-CODEW command.

● A new codeword is needed every time the purchased quantity is expanded.(Except "HIPATH AP VOICE COMPRESSION IP" where only the coding is dynamically changed (from G.729 to G.711) when the limit is reached.)The purchased quantity can be temporarily expanded in trial mode (see Section 1.2).

● An installed codeword only can be replaced by a new one. The creation date is saved in the codeword; the serial number is used for information purposes only.

● The codeword can be changed with the codeword tool.

● The hardware ID and codeword must match.

● In order to enter a codeword the date of the system must be valid.

● In the event of contractual violation, the user interface is disabled and you are prevented from starting any more SWU AMOs (for configuration).

● If the system prevents access although the codeword and dongle are valid, you can acti-vate the dongle with the following actions: unplug/plug in the dongle, enable line8 or per-form an A1 soft restart.

● Further information on the AMO CODEW can be found in the AMO description in theservice manual.

3.5 Generation (example)

● Add a codeword (dongle or SIM card must be inserted):

ADD-CODEW:CODEW1=W1RAZWX6HPK8HS5G39TKV6X9MKVAM9ENERJTVTZBDX34KFNHRUTP4GU1EC132N93,CODEW2=LJJ9MKK381DASTYEZNNU67366HMWAM33VVKKRKG7UHTDUGFWJN2PBBREGX;

EN4401EN00EN_0014© Siemens Enterprise Communications GmbH & Co. KG 2011. All rights reserved.Siemens Enterprise Communications GmbH & Co. KG is a trademark licensee of Siemens AG

17

Page 18: Mod08 Amos

18

AMOsSiemens

● Display counters for purchased quantities / configured quantities:

1. Customer Dongle / SIM (TYPE 1 - Codeword)

DISPLAY-CODEW;

H500: AMO CODEW STARDED

SALES UNIT COUNTERS

===================

CODEWORD: AFTKSB3CJYN4LKZN7GNWZH8TXH63M29A5GA2L2JN261LGKEA8CPHLZV5UGKHVPHP

XGRZDWDF83BG6BLE2U6LSP8GYS8VY5NADW88BUAE6RA58HXMD2N99TJSC9

VERSION : H205

SERIAL NUMBER: 7

HARDWARE ID : C6EB8F3B

ENTRY DATE : 22.02.2004

TRIAL MODE : NOT ACTIVATED

CONFIRMATION : 3706

+---------------------------------------------+-------+-------+-------+-------+

| | | | | |

| UNIT | CON- | USED | FREE |BLOCKED|

| | TRACT | | | |

+---------------------------------------------+-------+-------+-------+-------+

| COMSCENDO | 976 | 913 | 63 | |

| CORDLESS E | 0 | 0 | 0 | |

| PNE | 0 | 0 | 0 | |

| HIPATH PROCENTER ENTRY AGENT | 0 | 0 | 0 | |

| SIGNALING SURVIVABILITY | 0 | 0 | 0 | |

| CC-AP FOR AP EMERGENCY | 0 | 0 | 0 | |

+---------------------------------------------+-------+-------+-------+-------+

H07: THE TEST MODE IS AVAILABLE (ANOTHER) 2 TIMES.

AMO-CODEW-111 CODEWORD FOR ADMINISTRATION LOCK IN SWU

DISPLAY COMPLETED;

EN4401EN00EN_0014© Siemens Enterprise Communications GmbH & Co. KG 2011. All rights reserved.

Siemens Enterprise Communications GmbH & Co. KG is a trademark licensee of Siemens AG

Page 19: Mod08 Amos

AMOs Siemens

2. Dongle / SIM with TYPE 2 - Codeword

DISPLAY-CODEW;

DISPLAY-CODEW;

H500: AMO CODEW STARTED

SALES UNIT COUNTERS

===================

CODEWORD: 3SK2N24LR9RF4G9919DZL3GN8C8SVWTN7RX7BWNBCTLTZPGMZN9FBXP97RRFTT72

R283HCUX6LSJXW5YD147WGWTV9FXD2CZBSWN7RY63VL9R7ASMWJ546YM7R

VERSION : H205

SERIAL NUMBER: 0

HARDWARE ID : 7ED439FB

ENTRY DATE : 07.01.2004

VALID UNTIL : 17.12.2005

TRIAL MODE : NOT ACTIVATED

CONFIRMATION : 0

+---------------------------------------------+-------+-------+-------+-------+

| | | | | |

| UNIT | CON- | USED | FREE |BLOCKED|

| | TRACT | | | |

+---------------------------------------------+-------+-------+-------+-------+

| COMSCENDO | | 110 | | |

| CORDLESS E | | 0 | | |

| PNE | | 0 | | |

| HIPATH PROCENTER ENTRY AGENT | | 0 | | |

| SIGNALING SURVIVABILITY | | 0 | | |

| CC-AP FOR AP EMERGENCY | | 0 | | |

+---------------------------------------------+-------+-------+-------+-------+

H12: CURRENT CODEWORD IS A TYPE 2 CODEWORD.

AMO-CODEW-111 CODEWORD FOR ADMINISTRATION LOCK IN SWU

DISPLAY COMPLETED;

EN4401EN00EN_0014© Siemens Enterprise Communications GmbH & Co. KG 2011. All rights reserved.Siemens Enterprise Communications GmbH & Co. KG is a trademark licensee of Siemens AG

19

Page 20: Mod08 Amos

20

AMOsSiemens

Trial mode

The purchased quantity can be temporarily expanded with trial mode.Trial mode is activated with CHANGE-CODEW. Utilization is not unlimited (maximum number specified in codeword, generally 2) and has a maximum utilization time (generally 30 days).

SWU administration is not disabled even if license violation is shown in trial mode ("!!!!!" in the "FREE" column). A mark that can be displaced with the AMO SDSU is applied to elements that exceed the license limit (stations, trunks, etc.). The number of units marked is also displayed in the AMO CODEW.

Trial mode is automatically terminated if not manually deactivated within the maximum time lim-it. When this happens, marked elements are disabled for security reasons and can only be en-abled if an appropriate codeword is set up.

No elements are marked or disabled for the features HIPATH PROCENTER ENTRY AGENT and HIPATH AP VOICE COMPRESSION IP. However, when trial mode ends, no agents above and beyond the license limits can log on and compressed connections cannot be set up.

Trial mode does not apply to the features HIPATH AP REMOTE SURVIVABILITY and CC-AP FOR AP EMERGENCY. The codeword’s license limit cannot be exceeded here.

● Activate trial mode:

CHANGE-CODEW:TRIAL=YES;

....(activated after consultation)

● Administration above and beyond the quantities purchased:

ADD-SCSU:STNO=4711,DVCFIG=ANATE;

EN4401EN00EN_0014© Siemens Enterprise Communications GmbH & Co. KG 2011. All rights reserved.

Siemens Enterprise Communications GmbH & Co. KG is a trademark licensee of Siemens AG

Page 21: Mod08 Amos

AMOs Siemens

● Display codeword the test mode is expired:

DISPLAY-CODEW;

DISP-CODEW;

H500: AMO CODEW STARTED

SALES UNIT COUNTERS

===================

CODEWORD: 3SK2N24LR9RF4G9919DZL3GN8C8SVWTN7RX7BWNBCTLTZPGMZN9FBXP97RRFTT72

R283HCUX6LSJXW5YD147WGWTV9FXD2CZBSWN7RY63VL9R7ASMWJ546YM7R

VERSION : H205

SERIAL NUMBER: 0

HARDWARE ID : 7ED439FB

ENTRY DATE : 18.12.2003

VALID UNTIL : 17.12.2004

TRIAL MODE : NOT ACTIVATED

CONFIRMATION : 0

+---------------------------------------------+-------+-------+-------+-------+

| | | | | |

| UNIT | CON- | USED | FREE |BLOCKED|

| | TRACT | | | |

+---------------------------------------------+-------+-------+-------+-------+

| COMSCENDO | 110 | 110 | !!!!! | 1 |

| CORDLESS E | | 0 | | |

| PNE | | 0 | | |

| HIPATH PROCENTER ENTRY AGENT | | 0 | | |

| SIGNALING SURVIVABILITY | | 0 | | |

| CC-AP FOR AP EMERGENCY | | 0 | | |

+---------------------------------------------+-------+-------+-------+-------+

H12: THE TEST MODE IS AVAILABLE (ANOTHER) ONCE.

AMO-CODEW-111 CODEWORD FOR ADMINISTRATION LOCK IN SWU

DISPLAY COMPLETED;

EN4401EN00EN_0014© Siemens Enterprise Communications GmbH & Co. KG 2011. All rights reserved.Siemens Enterprise Communications GmbH & Co. KG is a trademark licensee of Siemens AG

21

Page 22: Mod08 Amos

22

AMOsSiemens

3.6 HiPath 4000 V6 Licensing

A new license concept based on the HiPath License Management (HLM) is used. The SIM card is not used anymore.

A HiPath 4000 V6 Flex License pro Port for all HiPath 4000 subscriber and Trunking connec-tions is available: analog, digital, HFA, SIP, Cordless, PSTN and SIP Service Provider.

EN4401EN00EN_0014© Siemens Enterprise Communications GmbH & Co. KG 2011. All rights reserved.

Siemens Enterprise Communications GmbH & Co. KG is a trademark licensee of Siemens AG

Page 23: Mod08 Amos

AMOs Siemens

HiPath 4000 V6 Flex License

subscriber analog per user

digital per user

IP (HFA or SIP) per user

trunk analog per channel

TDM per channel

Cornet IP Trunk and SIP Trunk for HG3550 Common Gateway

per channel

SIP Trunk for HiPath 4000 SoftGate no license required

SIP Service Provider per channel

Mobility Cordless Enterprise per channel base station

HiPath 4000 V6 Basis and Survivability License

System Base License per system

HiPath 4000 V6 Duplex Control per system

IP Access Point Signaling Survivability per AP3x00IP

Survivability Unit (AP-Emergency) per AP-Emergency Server

SoftGate 50 Base License per SoftGate Server

SoftGate 50 package max. 50 User and max. 50 active connections

SoftGate 1000 Basis License per SoftGate Server

SoftGate 1000 package max. 1000 User and max. 256 active connections

OpenScape 4000 V6 CSTA connectivity

CSTA CSTA connectivity with SEN Application part of the HiPath 4000 V6 base packet

Packet 10 User for 3rd party Application part of the HiPath 4000 V6 base packet

Packet 100 User for 3rd party Application per CSTA Application Link

Unlimited Packet for 3rd party Application per CSTA Application Link

Table 3-1

EN4401EN00EN_0014© Siemens Enterprise Communications GmbH & Co. KG 2011. All rights reserved.Siemens Enterprise Communications GmbH & Co. KG is a trademark licensee of Siemens AG

23

Page 24: Mod08 Amos

24

AMOsSiemens

After a first configuration with the Portal automatically a „grace period“ license will be generat-ed. This license is valid for 30 days.

A customer license must be created with MAC address (e.g. eth0 of the DSCXL2 board) and L-number. The created „.lic file“ can be downloaded with the Assistant. The Assistant creates a Codew for the RMX.

3.7 License Management in the HiPath 4000 Assistant V6

With the menu „HiPath 4000 Assistant V6 --> Access Management --> License Management“ the license can be downloaded and displayed.

EN4401EN00EN_0014© Siemens Enterprise Communications GmbH & Co. KG 2011. All rights reserved.

Siemens Enterprise Communications GmbH & Co. KG is a trademark licensee of Siemens AG

Page 25: Mod08 Amos

AMOs Siemens

The link „Display installed license data“ shows the licenses in detail, e.g. duration of validity.

The link “Display Server MAC address“ display the possible MAC addresses for the creation of the licenses.

EN4401EN00EN_0014© Siemens Enterprise Communications GmbH & Co. KG 2011. All rights reserved.Siemens Enterprise Communications GmbH & Co. KG is a trademark licensee of Siemens AG

25

Page 26: Mod08 Amos

26

AMOsSiemens

The Link “Display license details“ shows the actual used license data.

EN4401EN00EN_0014© Siemens Enterprise Communications GmbH & Co. KG 2011. All rights reserved.

Siemens Enterprise Communications GmbH & Co. KG is a trademark licensee of Siemens AG

Page 27: Mod08 Amos

AMOs Siemens

In the menu „HiPath 4000 Assistant V6 --> Access Management--> Licence Management --> Tool“ you can get information about the licenses, e.g. alarms.

3.8 Relevant AMO

AMO Parameter Sprache/Language

Beschreibung/ Description

EINR-CODEW CODEW1 d Erster Teil des Codewortes

CODEW2 d Zweiter Teil des Codewortes

ADD-CODEW CODEW1 e First part of codeword

CODEW2 e Second part of codeword

AE-CODEW TESTMOD d Testmodus ein/ausschalten

CHANGE-CODEW TRIAL e Activate/deactivate trial mode

AB-SDSU LICMARK d Markierte Lizenz (im Testmodus)

LICBLOCK d Gesperrte Lizenez (Testmodus abgelaufen)

DISP-SDSU LICMARK e Marked License (in testmode)

LICBLOCK e Blocked License (testmode expired)

EN4401EN00EN_0014© Siemens Enterprise Communications GmbH & Co. KG 2011. All rights reserved.Siemens Enterprise Communications GmbH & Co. KG is a trademark licensee of Siemens AG

27

Page 28: Mod08 Amos

28

AMOsSiemens

EN4401EN00EN_0014© Siemens Enterprise Communications GmbH & Co. KG 2011. All rights reserved.

Siemens Enterprise Communications GmbH & Co. KG is a trademark licensee of Siemens AG

Page 29: Mod08 Amos

AMOs Siemens

4 AMOs in the User Area

Messen-ger no.

STNNo.

ITR groupUser no.WABE group

List no. COS no.LCOS (V/D)

COSSUClasses of

service

LRNGZSPDC lists and

Speed dialing No.

VBZITR matrix

WABEDialing plan

TACSULine config.

individual night STN

VBZAITR matrixID card, IDcard reader

TGERSharing of

NV terminals

SSCSpecial Subscr.MESSENGER

ZRNGZSPDC

dest. callnumbers

HOTLNHotline/

Code blue Destinations

TAPROKey

programmingindiv.

BERUMCOSX

manually controlled

BERUZCOSX time

controlled

NAVARNight

options

SAHunt group

data

Secretary

STNNo.

RNGZ 1, 2

ITR groupCOSXgroup

SCSU / SBCSUPer STN No. personal and

device-related data

PERSIPersonal

identificationPIN / Name

ZIELDest. no. for MESSGR, FWD,

No.Redial, SPDI, DSS, Name, dest. key

RUFUMNumber mapping

combi-code

AUNCall pick-up

group

SDATAdministration of subscr.-related

features.

SXSUSTN

Exchange of Voice Terminals

CHESEExec./secretary

system

ZAND

ZANDE

TAPROStandard

RCSUAdding music

per user

EN4401EN00EN_0014© Siemens Enterprise Communications GmbH & Co. KG 2011. All rights reserved.Siemens Enterprise Communications GmbH & Co. KG is a trademark licensee of Siemens AG

29

Page 30: Mod08 Amos

30

AMOsSiemens

AUN Call pick-up groups

BERUM Class-of-service changeover

BERUZ Class-of-service changeover times

CHESE Executive/secretary system (integrated outer office system)

COSSU Classes of service

HOTLN Destinations for HOTLINE/CODE BLUE

LRNGZ Lists for central number generator

NAVAR Administration of the stat. night variant data

PERSI Personal identification

RCSU Announcement devices in the SWU

RUFUM Number mapping

SA Hunt group

SBCSU Terminals and S0 bus configuration in the SWU

SCSU Configuration of users in the SWU

SDAT Administration of user-related features

SSC Configuration of special users

SXSU Reconfiguration of user voice terminals

TACSU Configuration of analog line ports

TAPRO Key programming for digital terminals

TGER User devices assignment

VBZ Internal traffic restriction (ITR) matrix

VBZA ITR for users with ID card readers

VBZGR ITR groups

WABE Dialing assessment

ZAND Central system data

ZANDE Central system data - extended

ZIEL Destination addresses for users

ZRNGZ Central number generator destinations

EN4401EN00EN_0014© Siemens Enterprise Communications GmbH & Co. KG 2011. All rights reserved.

Siemens Enterprise Communications GmbH & Co. KG is a trademark licensee of Siemens AG

Page 31: Mod08 Amos

AMOs Siemens

5 WABE - Digit Analysis

"Digit analysis" refers to the assignment of a digit analysis result (DAR) to a dialed digit se-quence or code. This assignment is dependent on the call progress state (CPS) and digit anal-ysis group or dial plan (DPLN). There are two types of digit analysis result: DARs with a specific dialing outcome (e.g. ’STN’; dialing result is station number), and DARs whose dialing outcome must be defined in other AMOs (e.g. ’CO’; the trunk routes which can be accessed via this DAR are defined with the AMO RICHT).

5.1 Structure of the DPLN

Digit Analysis is comprised of a general DPLN (WABE) part and one of 16 DPLN groups.

DPLN - General Part (valid for all dial plans)

Here are listed all codes for those digit analysis results (DAR) which are to be accessible for all stations (valid for all dial plans).

All stations (DAR=STN) must be listed here.

DIS-WABE:GEN;

Displays only the general part!

DPLN 0 DPLN 1 DPLN 2 . . .14 DPLN 15

Codes for digit analysis results (DAR) in this area are only accessi-ble for stations belong-ing to DPLN 1.

Station Number 4511 DIS-WABE:GEN,1;

Displays all DPLN entries for stations with DPLN 1.(DPLN general part and DPLN 1)

If STN is assigned to DPLN 1, SCSU/S(B)CSU must have parameter DPLN=1.

With this he gets access to all codes of the DPLN valid for all DPLN groups as well as the codes of DPLN 1.

EN4401EN00EN_0014© Siemens Enterprise Communications GmbH & Co. KG 2011. All rights reserved.Siemens Enterprise Communications GmbH & Co. KG is a trademark licensee of Siemens AG

31

Page 32: Mod08 Amos

32

AMOsSiemens

5.2 Overview DARs

General DARs

ALL All DAR´s

ACBK Activate callback

DCBK Delete callback or line queueing

ACOSX Activate cos changeover from station

DCOSX Deactivate cos changeover from station

ADND Activate do not disturb

DDND Deactivate do not disturb

ANSCO Answering device for central office

ANSINT Answering device, internal

APIN1 to APIN 15

Activate PIN for COPIN 1 to Activate PIN for COPIN 15

DPIN Deactivate PIN

AREM Activate reminder

DREM Deactivate reminder

ATND Attendant / internal operator code

ATNDDID Indial to attendant console

ATNDIND Individual attendant console

BABYLSNG Baby listening

BUZZ Alert (buzz) a target station

CDRACC CDR account code

CO Central office

CTDL Seize lines

DICT Dictation equipment

DIGIDAT DIGITE data input

DISUOFF Display suppression off

EN4401EN00EN_0014© Siemens Enterprise Communications GmbH & Co. KG 2011. All rights reserved.

Siemens Enterprise Communications GmbH & Co. KG is a trademark licensee of Siemens AG

Page 33: Mod08 Amos

AMOs Siemens

DISUON Display suppression on

DOORCL Query of the entrance telephone system

DOOROPEN Open via the entrance telephone system

DTE Code for DTE service for analog traffic via DIUC

DTED Code for DTE service for digital traffic via DIUC

DTMFCONV DTMF conversion when dailing to public network

EOVR Emergency override (feature emergency override/release)

EXTANS Interception by console in partner system

FAX Code for Fax service

GATEWAY Gateway

GENANS General answering / universal night answering

HOLD Call hold by an analog phone

KNOVR Camp on (knocking) / override

LNR Last number redial

MANDOWNL Manual downloading

MHFALGOF Logoff by a mobile HFA subscriber

MHFALGON Logon by a mobile HFA subscriber

NETRTE Auxiliary DAR for networking

NETW DAR for a voice feature in another node, route is automatically seized via DESTNO and the dialed digit sequence is repeated

NETWDTE DAR for a DTE feature in another node, route is automatically seized via DESTNO and the dialed digit sequence is repeated

NETWFAX DAR for a FAX feature in another node, route is automatically seized via DESTNO and the dialed digit sequence is repeated

NOPT Change of night switch option

OUTPULSE Outpulse specific digits on the line during call status for cut-through or suffix dialing in tie traffic

OWNNODE Code number for own node

PUEXT Acceptance (or pickup) of ext.consult call from remote system in simple tie trunk traffic

EN4401EN00EN_0014© Siemens Enterprise Communications GmbH & Co. KG 2011. All rights reserved.Siemens Enterprise Communications GmbH & Co. KG is a trademark licensee of Siemens AG

33

Page 34: Mod08 Amos

34

AMOsSiemens

RA Recorded announcement for a specific area

RELEASE Release (feature emergency override/release)

REMKY Reminder Key

RESDOWNl Reset of modified parameters by downloading the basic parameter sets (DCI)

SIGNOFF Sign off a line via terminal device (Autoset Relocate)

SIGNON Sign on a line via terminal device (Autoset Relocate)

SNR Stored number redial

SPD Change the speed (DCI)

SPDC1 Speed dialing central 1

SPDC2 Speed dialing central 2

SPDI Speed dialing individual

SPDIPROG Speed dialing individual programming code

SPLIT Split / alternating calls

STN Station

STNREL STN DAR for destination dependent release

TRACE Malicious call tracing

VOICECAL Voice call

WHISANN Whisper Announcement

DARs for call forwarding feature

for voice service

AFWDVCE Activate fixed call forwarding voice

DFWDVCE Deactivate fixed call forwarding voice

AFFWDVCE Program and activate fixed forwarding voice

DFFWDVCE Deactivate and delete fixed forwarding voice

for Fax service

AFWDFAX Activate call forwarding fax

DFWDFAX Deactivate call forwarding fax

EN4401EN00EN_0014© Siemens Enterprise Communications GmbH & Co. KG 2011. All rights reserved.

Siemens Enterprise Communications GmbH & Co. KG is a trademark licensee of Siemens AG

Page 35: Mod08 Amos

AMOs Siemens

AFFWDFAX Program and activate fixed forwarding fax

DFFWDFAX Deactivate fixed forwarding fax

for DTE service

AFWDDTE Activate call forwarding DTE

DFWDDTE Deactivate call forwarding DTE

AFFWDDTE Activate fixed call forwarding DTE

DFFWDDTE Deactivate fixed call forwarding DTE

Activate via the attendant console

AFWDREM Activate call forwarding remote / follow me

DFWDREM Deactivate call forwarding remote / follow me

FWDREM Show call forwarding remote / follow me

Miscellaneous

AFWDDWD Activate call forwarding for DIGITE without display

FWDTERM Call forwarding for all STNs assoc. to terminal

FWDIGNOR Ignore call forwarding

DFWDEXT Deactivate call forwarding external

AFWDEXT Activate call forwarding external

DFWDINT

AFWDINT

Deactivate call forwarding internal

Activate call forwarding internal

AFWDEXIN Activate call forwarding internal

AFWDB Activate call forwarding busy

AFWDNA Activate call forwarding no answer

AFWDBNA Activate call forwarding busy or no answer

DSYSFWD Deactivate system call forwarding voice

ASYSFWD Activate system call forwarding voice

FFWDREMK Store call forwarding via remote by key

EN4401EN00EN_0014© Siemens Enterprise Communications GmbH & Co. KG 2011. All rights reserved.Siemens Enterprise Communications GmbH & Co. KG is a trademark licensee of Siemens AG

35

Page 36: Mod08 Amos

36

AMOsSiemens

DARs for call pickup feature

PU Call pickup

PUGDIS Display group pickup information on request

PUDIR Directed call pickup

DARs for call park feature

PARK Call park and retrieve to system slot

CALLPARK Call park for anate

DCPA Park a user at a specific user

SELFPA Park a user on one´s own line

RECONNPA Reconnect on held call

DARs for combi code feature

DTEDNE Combi code for DTE terminal with digital traffic via DIUC

DTENO Combi code for DTE terminal with analog traffic via DIUC

FAXNO Combi code for FAX terminal

DARs for hunting group feature

HUNT Hunting group (HT)

HTKY Hunt group key (on / off)

AHTVCE Add station to hunt group voice

DHTVCE Disassociate stn from hunt group, voice eqpt.

AHTFAX Add station to hunt group fax

DHTFAX Disassociate station from hunt group, fax eqpt.

AHTDTE Add station to hunt group DTE

DHTDTE Disassociate stn from hunt group, DTE eqpt.

EN4401EN00EN_0014© Siemens Enterprise Communications GmbH & Co. KG 2011. All rights reserved.

Siemens Enterprise Communications GmbH & Co. KG is a trademark licensee of Siemens AG

Page 37: Mod08 Amos

AMOs Siemens

DARs for code calling feature

(Single code calling / multiple code calling)

CCKY Code calling key

CCDIS Code calling display with code

CCMEETME Code calling meet me with code

CCSTN Code calling station A with code

CCVCE Code calling for voice with code

CCSURG Code calling urgent search with code

CCS Code calling normal search with code

CCANS Code calling answer

CCSCD Code calling search with code

CCSN Code calling search normal

CCMANS Code calling answer to multi task page attempt

CCMSURG Code calling multiple paging urgent

CCMS Code calling multiple task paging normal

DARs for tie traffic feature

(network / wide features)

TIE Tie line access

TIEATND Analogue tie line, special seizure type

SCONSCO Sat. connection in consultation hold from CO

SCONSI Sat. connection in consult hold from internal

SAT Extend indial or trunk call to satellite system

DARs for IP Distributed Architecture (IPDA) feature

FRCALTRT Force alternate route

INCALTRT Incoming alternate route

NOEC CLC without echo cancellation for encrypted calls

EN4401EN00EN_0014© Siemens Enterprise Communications GmbH & Co. KG 2011. All rights reserved.Siemens Enterprise Communications GmbH & Co. KG is a trademark licensee of Siemens AG

37

Page 38: Mod08 Amos

38

AMOsSiemens

DARs for key function assignment

KYPROG Key programming on digite

KNOVRKY Knocking / Camp on, override key

DNDKY Do not disturb

IUSEKY Show line key i use key

FWDKY Call forwarding key

MSGRKY Messenger key (CHESE)

MBKY Mailbox key

DAKY Non-Voice key

VCRKY Voice call reject key

VCKY Voice call key

DSSKY Direct station select key

EXHOLDKY Exclusive hold key

HOLDKY Hold key

CONFKY Conference key

TOGGLEKY Toggle key

NAMEKY Name key

PARKKY Park key

PRIVKY Privacy key

CONSKY Consultation key

CBKKY Callback key

RCTOFFKY Ringer cutoff key

HTKY Hunt group key (on / off)

FLASHCD Equivalent flash signal code

STKY Start key / output

RLSKY Release / Cancel key

TRNSKY Call transfer key

TIMEKY Time / date key

EN4401EN00EN_0014© Siemens Enterprise Communications GmbH & Co. KG 2011. All rights reserved.

Siemens Enterprise Communications GmbH & Co. KG is a trademark licensee of Siemens AG

Page 39: Mod08 Amos

AMOs Siemens

LNRKY Last number redial key

SNRKY Saved number redial key

DARs for answering machine functions

MBON Mailbox LED on

MBOFF Mailbox LED off

VMOWN Access to own voice mailbox

VMFOR Access to other user´s voice mailbox

MWACT Message waiting activation

MWANS Message waiting answer

MWCAN Message waiting cancel by terminating party

MWCANORI Message waiting cancel by originating party

DARs for broadcast functions

BROADCST speaker call - one way broadcast

COMGRP COM group call

COMSPK COM group speaker call - two way

SPKRCALL Speaker call - one way

DARs for conference features

CONFKY Conference key

CONF Establish conference / add party to conference

RMCONFLP Remove last party from conference

RMCONFP1to RMCONFP8

Remove party at position 1 from conference up toRemove party at position 8 from conference

DARs for MLPP features

FLASH MLPP flash call

FLASHOV MLPP Flash Override call (high level)

EN4401EN00EN_0014© Siemens Enterprise Communications GmbH & Co. KG 2011. All rights reserved.Siemens Enterprise Communications GmbH & Co. KG is a trademark licensee of Siemens AG

39

Page 40: Mod08 Amos

40

AMOsSiemens

IMMED MLPP immediate call

PRTY MLPP priority call (low level)

DSNR MLPP dsn routine

DARs for call center features

ACC Account code

ACDWORK Agent work

ACDSHMSG Short message

ACDLOGON Agent logon

ACDLOGOF Agent logoff

ACDEMMSG Emergency message

ACDNAV Agent not available

ACDPGS Primary group status

ACDPQS Primary queue status

ACDSGS Secondary group status

ACDSQS Secondary queue status

ACDAV Agent available

CAFDFWD CAF deactivate forwarding of RCG

CAFAFWD CAF activate forwarding of RCG

CAFGROFF CAF group logoff

CAFGRNAV CAF group not available

CAFGRAV CAF group available

CAFLOGOF CAF agent logoff

CAFNAV CAF agent not available

CAFAV CAF agent available

MONSLNT Silent monitoring

MONTONE Tone monitoring

RCG Route control group number

EN4401EN00EN_0014© Siemens Enterprise Communications GmbH & Co. KG 2011. All rights reserved.

Siemens Enterprise Communications GmbH & Co. KG is a trademark licensee of Siemens AG

Page 41: Mod08 Amos

AMOs Siemens

DARs for key functionality feature

IUSEKY Show line key i use key

EXHOLDLKY Exclusive hold key

HOLDKY Hold key

KEYPADIE Keypad IE

TOGGLEKY Toggle Key

APRIV Activate privacy

DPRIV Deactivate privacy

PRIVKY Privacy key

CONSKY Consultation key

CBKKY Callback key

RCTOFFKY Ringer cutoff key

RLSKY Release / Cancel key

TRNSKY Call transfer key

LNRKY Last number redial key

SNRKY Saved number redial key

DARs for national features

PROT Override protection (Belgium)

ASTN Check a Station number in the case of transit

CALLPARK Call park for anate

OPROVR Demand to override by CO operator in call status

DCPA Park a user at a specific user

SELFPA Park a user on one own line

RECONNPA Reconnect on held call

RERING Ring partner again

CTDL Line seizure for cut through or suffix dailing in tie traffic

OUTPULSE Suffix transmission of digits on the line during call status for cut through or suffix dailing in tie traffic

EN4401EN00EN_0014© Siemens Enterprise Communications GmbH & Co. KG 2011. All rights reserved.Siemens Enterprise Communications GmbH & Co. KG is a trademark licensee of Siemens AG

41

Page 42: Mod08 Amos

42

AMOsSiemens

DARs for the Optiset API feature

WSS Start workstation session

DARs for service functions

FLTRACE Activate the flag trace

FREQTEST Test the DTMF and MFC transmitters

CTLS Controlled Trunk and Line Selection

HWTEST Start the HW test of the terminal (optiset)

TESTLN Test line

TESTTONE Connect test tone transmitter for 800hz test

COMBO Combination test (transmission test termination)

LOOPBACK Loopback test (transmission test termination)

MILLWAT Milliwatt test (transmission test termination)

SILENCE Silence test (transmission test termination)

PRITEST Primary rate test line loopback

EN4401EN00EN_0014© Siemens Enterprise Communications GmbH & Co. KG 2011. All rights reserved.

Siemens Enterprise Communications GmbH & Co. KG is a trademark licensee of Siemens AG

Page 43: Mod08 Amos

AMOs Siemens

5.3 Overview of the CPS

Possible AMO values: 0 - 22 (from Version V 2.3 --» V 3.x )

0 Auxiliary CPS for networking (DAR NETRTE)

1 Suffix dialing (station / attendant)

2 Switching of in-house call at attendant console

3 Switching of central office call at attendant console

4 Prefix dialing at attendant console

5 Prefix dialing by station

6 CO incoming DID

7 IDN connection from CO incoming DID

8 Consultation of station user from in-house call

9 Consultation of a station user from CO call

10 Incoming station line traffic

11 Incoming tie line traffic

12 Incoming link traffic

13 Seizure from satellite PABX for data traffic

14 CHECK mode on attendant console

15 CHECK mode on HICOM terminal

16 Seizure in private network

17 Seizure during consultation in private network

18 Single code calling device: code digits in suffix dialing

19 Expiration of time supervision

20 Function assignment to key on HICOM terminal

21 Used only in USA

22 Consultation of station user from conference

EN4401EN00EN_0014© Siemens Enterprise Communications GmbH & Co. KG 2011. All rights reserved.Siemens Enterprise Communications GmbH & Co. KG is a trademark licensee of Siemens AG

43

Page 44: Mod08 Amos

44

AMOsSiemens

Associated pairs for simultaneous processing are listed in Table 5-1 and pairs for sequential processing in Table 5-2. Digit analysis results AFWDVCE, ADND and ACOSX can also be used as 'feature toggling' digit analysis results. Thus, in the case of these digit analysis results, it is no longer necessary to handle them in pairs with the corresponding deactivation digit analysis results.

There are more features connected to special DARs, e.g. there are only decimal digits allowed with DAR STN or FLASHCD, also only 1 digit is allowed for DAR FLASHCD

Add simultaneously

DAR 1 DAR 2

AFWDREM DFWDREM

AFWDDTE DFWDDTE

AFWDFAX DFWDFAX

AFFWDDTE DFFWDDTE

AFFWDFAX DFFWDFAX

AFFWDVCE DFFWDVCE

ACBK DCBK

AHTDTE DHTDTE

AHTFAX DHTFAX

AHTVCE DHTVCE

AREM DREM

VMOWN VMFOR

MBON MBOFF

Table 5-1 Digit analysis result pairs

Must be entered in sequence

Enter first Enter second

SPDC1 SPDC2

CCS CCSURG

CCMS CCMSURG

Table 5-2 DAR pairs for sequential processing

EN4401EN00EN_0014© Siemens Enterprise Communications GmbH & Co. KG 2011. All rights reserved.

Siemens Enterprise Communications GmbH & Co. KG is a trademark licensee of Siemens AG

Page 45: Mod08 Amos

AMOs Siemens

Function:

● ADD Assign digit analysis results

● CHA Change digit analysis results

● DISPLAY Delete digit analysis results

● DEL Display digit analysis results

● REG Regenerate digit analysis results

EN4401EN00EN_0014© Siemens Enterprise Communications GmbH & Co. KG 2011. All rights reserved.Siemens Enterprise Communications GmbH & Co. KG is a trademark licensee of Siemens AG

45

Page 46: Mod08 Amos

46

AMOsSiemens

EN4401EN00EN_0014© Siemens Enterprise Communications GmbH & Co. KG 2011. All rights reserved.

Siemens Enterprise Communications GmbH & Co. KG is a trademark licensee of Siemens AG

Page 47: Mod08 Amos

AMOs Siemens

6 VBZ - Internal Traffic Restrictions

The internal traffic restriction matrix regulates communications among the traffic groups (ITR groups). Stations and trunks are combined into ITR groups which have an identical traffic re-striction matrix, i.e. which have the same traffic restrictions to other ITR groups.

Relations between ITR groups can be set up and changed as desired with the ITR matrix.

Only a portion of the total communications of the switching unit is regulated with the ITR matrix. The matrix is only queried when the dialing outcome is a station (also master station in a hunt group).

The following traffic relations between two groups are possible:

● A = allowed

● D = denied

Thus directional traffic restrictions between two ITR groups can also be regulated.

The traffic relation within one group must always be allowed. For that reason, the diagonal line of the matrix may not be altered (always contains the entry "A").

A second static matrix is used to regulate traffic relations between card users and card readers. This matrix is administrated by the AMO VBZA.

The features "controlled station restriction" and "controlled station restriction - group", as well as "controlled station-to-station restriction", do not affect the ITR matrix. For these features, a separate table exists, which is administrated by the AMO ACTDA.

The ITR matrix is created from the database and initialized with A (= allowed). As a result, an ADD branch for the AMO VBZ is not necessary.

Function:

E.g.: ITR-Gr 05 --> 03 allowed

ITR-Gr 03 --> 05 denied

● DISPLAY Interrogate the ITR matrix

● CHANGE Change the ITR matrix

● REGENERATE Regenerate the ITR matrix

EN4401EN00EN_0014© Siemens Enterprise Communications GmbH & Co. KG 2011. All rights reserved.Siemens Enterprise Communications GmbH & Co. KG is a trademark licensee of Siemens AG

47

Page 48: Mod08 Amos

48

AMOsSiemens

EN4401EN00EN_0014© Siemens Enterprise Communications GmbH & Co. KG 2011. All rights reserved.

Siemens Enterprise Communications GmbH & Co. KG is a trademark licensee of Siemens AG

Page 49: Mod08 Amos

AMOs Siemens

7 COSSU - Classes of Service

The classes of service contain combinations of authorizations and features and are assigned to one ore more stations (AMO-ACSU, AMO-SBCSU, AMO-SCSU resp. AMO-SSCSU). Class-es of service are also assigned to trunks for call traffic (AMO-TACSU, AMO-TDCSU resp. AMO-TSCSU).

Each class of service is divided into 3 services:

– Voice (VCE)

– Facsimile (FAX)

– Data Terminal (DTE)

Table 1 shows the COS authorizations, a description of the authorization, the service in which each authorization is applicable, and whether an autorization effects a station and/or a trunk. This table is only a compilation of classmarks. It does not allow you to establish cross-referenc-es between the different authorizations.

The -without direct trunk access- and -without tie trunk access- authorizations for the specified service are indicated by the fact that the direct trunk access and tie trunk access authorizations are not set for the corresponding service.

● COS 0 is not a valid class of service.

● LCR classes of service

Change, display, and regenerate LCR classes of service, each with up to 64 LCR authori-zations and LCR options (for example, LCR expensive route tone).

Sixty-four LCR classes of service are permanently configured, 32 of which are for voice, fax, and 32 of which are for data.

LCOSV=1 is initialized for the attendant console with all the authorizations. The others are initialized without contents and edited by means of the branch CHANGE

EN4401EN00EN_0014© Siemens Enterprise Communications GmbH & Co. KG 2011. All rights reserved.Siemens Enterprise Communications GmbH & Co. KG is a trademark licensee of Siemens AG

49

Page 50: Mod08 Amos

50

AMOsSiemens

Authoriza-tion

Description ServiceVCE.FAX .DTE

Application STA ...TRU

General Classmarks

ACTMAN Manual CDR Account Code possible X X X X

ANSYN Announcements with synchronized start of text

X X

APHOT Application hotline X X

ATRACE Automatic station number identification X X

BASIC Basic device authorization X X X

BDCP Disable selective call pickup X X

COIN Coinbox telephone X

COSXD Class-of-service changeover with code X X

CTLS Selective trunk and station dialing X X

DATA Non-voice data authorization X X

DICT Dictation authorization X X

DSSKEY KEY functionality with DSS key X X

DPSTN Dial pulsing X X X X

DSM Access to service module (DTE) X X

DNDOVR Override do not disturb X X

DIDBLK DID barring X X X X

FAX Access to service module (FAX) X X

GRPCAL Group call X X

HGICLD Hunt group code in call party number X X X X

HOT HOT Hotline X X X

INATCP International call in private network X X X X

LOCCPV Local connection in private network X X X X

MANOV Manual override X X

MB Mailbox (authorization to read mail) X X

EN4401EN00EN_0014© Siemens Enterprise Communications GmbH & Co. KG 2011. All rights reserved.

Siemens Enterprise Communications GmbH & Co. KG is a trademark licensee of Siemens AG

Page 51: Mod08 Amos

AMOs Siemens

MTRACE Manual station number identification X X

NOARNO Ports to which recall is not permitted X X

NOCHRG Without call charges X X X

NOPTCD Change night service variant of an AC group via code

X X

NPINDP No pin for dailing pattern required X X

OFHKRC Off hook recall X X

PINAFM PIN Identification and Follow-Me in one step X X

RKOABS Absolute override/camp-on security X X

REVCHA Reception of a collect call X

RSVLN Access to reserved trunks X X

SPKR Loudspeaker announcement authorization X

SUBEPP Consulting party is responsible for call charg-es

X

SUTVA Station can transfer before answer X X

TOLLPV National call in private network X X X X

TRACE Automatic call trace X X

TRANSG Indirect access to private network X

TTT Transfer Trunk to Trunk X X X X

VCE Access to service module (Voice ) X X

General Country-Specific Authorizations

PRCO External party with priority X

PRCO1 External party 1 with priority X

PRISTN Station with priority X

TSUID External party identification X X X X

Call Forwarding

CFB Call forwarding on busy X X

Authoriza-tion

Description ServiceVCE.FAX .DTE

Application STA ...TRU

EN4401EN00EN_0014© Siemens Enterprise Communications GmbH & Co. KG 2011. All rights reserved.Siemens Enterprise Communications GmbH & Co. KG is a trademark licensee of Siemens AG

51

Page 52: Mod08 Amos

52

AMOsSiemens

CFNR Call forwarding on no reply X X

CFSWF Automatic changeover to fixed call forwarding after deactivating variable call forwarding

X X

FWDBAR Prevent call forwarding X X

FWDECA CF-EXT as a function of COS 1 / 2 X X

FWDEXT Extended call forwarding X

FWDNWK Call forwarding to exchange X

Emergency Override/Emergency Disconnect

AOBTR Autom. emergency override to busy trunk X X

REOVR Rejection of emergency override/disconnect X X

Direct Trunk Access and Tie Trunk Access Authorizations

NOCO Without direct trunk access X X X X

RTA Restricted trunk access X X X X

TA Unrestricted toll access authorization X X X X

NOTIE Without tie trunk access X X X X

RTIEA Restricted tie trunk access X X X X

TTCR11 Partial tie trunk access authorization 1 X X X X

TTCR12 Partial tie trunk access authorization 2 X X X X

TTCR13 Partial tie trunk access authorization 3 X X X X

TTCR14 Partial tie trunk access authorization 4 X X X X

TTCR15 Partial tie trunk access authorization 5 X X X X

TTCR16 Partial tie trunk access authorization 6 X X X X

TNOTCR Tie trunk access authorization X X X X X

EURO-ISDN Terminals

MSN Multiple Subscriber Number X X X X

MULTRA Multi-Trans (called terminal seized several times) X X X X

OVCAT Override Category X X X X

Authoriza-tion

Description ServiceVCE.FAX .DTE

Application STA ...TRU

EN4401EN00EN_0014© Siemens Enterprise Communications GmbH & Co. KG 2011. All rights reserved.

Siemens Enterprise Communications GmbH & Co. KG is a trademark licensee of Siemens AG

Page 53: Mod08 Amos

AMOs Siemens

SPECAR Special arrangement X X X X

SUBCAL B is notified of A station number X X X X

SUBDB B is notified of default B station number X X X X

SUBMSN B is notified of MSN X X X X

Services on DSS1 - Multi-Device Connection

CCBS Completion of calls to busy subscribers X X X X

COLR Connected line identification restriction X X X X

CW Call waiting X X

MCIDM Malicious Call Identification - manual X X X

MCIDA Malicious Call Identification - automatic X X X

TP Subscriber not in call pickup group X

UUS1IM Implicit use of UUS1 service X X X

UUS3 Use of UUS3 service X X X

QSIG + DSS1 to the Public Exchange

FWDBAS Call forwarding programmed by another sub-scriber

X X X X

FWDDIR Activation, deactivation and display of incom-ing call forwarding

X X X X

FWDFAS Call forwarding programmed for another sub-scriber

X X X X

KIESIG Keypad IE signaling possible X X X X

Call Charge Identification for Data Selection

CDRATN Call detail recording at attendant console X X

CDRC Call detail recording central X

CDRINT Call detail recording of internal call X X X X

CDRSTN Call charge display during the call X X X X X

CDRS Call detail recording per station X X

Authoriza-tion

Description ServiceVCE.FAX .DTE

Application STA ...TRU

EN4401EN00EN_0014© Siemens Enterprise Communications GmbH & Co. KG 2011. All rights reserved.Siemens Enterprise Communications GmbH & Co. KG is a trademark licensee of Siemens AG

53

Page 54: Mod08 Amos

54

AMOsSiemens

Functions

Features for Public Telephones with Metering Pulses(these class marks can be released on a country specific basis only)

MTEQ Maintenance equipment X

PUPHON Public telephone X

SCRNCA Station with no charge party A X

SCRNCB SCRNCB Station with no charge party B X

SCRSPC Station with special call detail recording X

China

Service Documentation

Spain

Service Documentation

ANI outgoing GUS

Service Documentation

GUS Stufe 2&3

Service Documentation

● ADD Add a Class of Service

● CHANGE Change of Classes of Service

● DELETE Delete Classes of Service

● DISPLAY Display Classes of Service

● REGENERATE Regenerate Classes of Service

Authoriza-tion

Description ServiceVCE.FAX .DTE

Application STA ...TRU

EN4401EN00EN_0014© Siemens Enterprise Communications GmbH & Co. KG 2011. All rights reserved.

Siemens Enterprise Communications GmbH & Co. KG is a trademark licensee of Siemens AG

Page 55: Mod08 Amos

AMOs Siemens

8 TAPRO - Key Programming

The AMO TAPRO is used for loading the programmable key functions of digital and IP voice terminals.

Various standard or individual key assignments can be loaded. The AMO TAPRO also allows individual key functions to be changed. Furthermore, the AMO is used for the administration of the standard key assignments. As Spirit IP Phones will be configured using the already existing opti-IP device configuration, the required TAPRO functionality to allow administration of Key Layouts for Spirit IP Phones (with or without Key System Functionality) is already present. TAP-RO is extended to delete information on which type of Electronic Key Label shall be used and which individual text shall be used for the Electronic Key Label

In the generation sequence, AMO TAPRO is called at two points in the batch: before AMO SBC-SU to change standard key assignments, and after AMO SBCSU/SSCSU to change individual keys

Functions

The AMO TAPRO can be used for the following terminal types:

● optiset E T3 / T8 / T12

● optiPoint 500 T8 / T12 / T19

● optiPoint 600 T19

● optiPoint 4x0 T8 / T12 / T19

● optiPoint WL2 professional

● OpenStage 10, 15, 20, 30, 40,60 and 80

● OpenClient

● as well as the various add-on terminal types

With the AMO TAPRO, it is not necessary to set up the standard key assignments, since all 127 for optiset valid standard assignments for each terminal type are already stored in the data-base. All terminals are allocated one of these standard assignments when they are first config-ured.

● The terminal will be not deactivated from the AMO TAPRO, exception deletion of DSS keys.

● If the terminal was deactivated before the processing, it remain deactivated.

● A standard key layout with add-on terminal can be assigned to a subscriber OPTISET with-out add-on terminal, but only the key functions of the basic terminal are accepted.

EN4401EN00EN_0014© Siemens Enterprise Communications GmbH & Co. KG 2011. All rights reserved.Siemens Enterprise Communications GmbH & Co. KG is a trademark licensee of Siemens AG

55

Page 56: Mod08 Amos

56

AMOsSiemens

● Zulässige Angaben und ihre Bedeutung

DISPLAY-TAPRO:TYPE=STN,STNO=7243;

+--------------+----+---------+------------------------------------------------+

| STATION |STD | DIGTYP | FUNCTION KEYS WHICH DIFFER FROM STANDARD |

+--------------+----+---------+------------------------------------------------+

| 7243 |101 | OPTISET | |

+--------------+----+---------+------------------------------------------------+

CHANGE-TAPRO:STD=101,DIGTYP=OPTIT19,KY09=DSS;

DISPLAY-TAPRO:TYPE=STN,STNO=7243;

+--------------+----+---------+------------------------------------------------+

| STATION |STD | DIGTYP | FUNCTION KEYS WHICH DIFFER FROM STANDARD |

+--------------+----+---------+------------------------------------------------+

| 7243 |101 | OPTISET | 9 DSS |

+--------------+----+---------+------------------------------------------------+

OptionsforSTD,STNO

Basic terminal(s) Add-onterminal(s)

No terminaltypespecified

STD Load new std. key layout for sp. basic terminal type

Load new standard key layout for add-on terminal

Error messageF03

STND Load new function for freely-prog., ind. keys at sp. STNs with sp. (basic) terminal type

Load new function for freely-programmable, in-div. keys at specified add-on terminal.

Load new function for freely prog., ind. keys at spec. terminals

STNO and STD

Load new standard key layout plus new functions for freely-prog., ind. keys at spec. STNs with spec. (basic) terminal type.

Error messageF05

Load new std. key layout at spec. STN and freely-prog. key functions at ba-sic terminal.

EN4401EN00EN_0014© Siemens Enterprise Communications GmbH & Co. KG 2011. All rights reserved.

Siemens Enterprise Communications GmbH & Co. KG is a trademark licensee of Siemens AG

Page 57: Mod08 Amos

AMOs Siemens

Function

● CHANGE Change a standard key layout Change freely-programmable key layout

● DISPLAY Display standard and freely-programmable key layoutsDisplay standard key layouts Display freely-programmable key layouts

● REGENERIATE Regenerate standard and freely-programmable key layouts Regenerate standard key layouts Regenerate freely-programmable key layouts

EN4401EN00EN_0014© Siemens Enterprise Communications GmbH & Co. KG 2011. All rights reserved.Siemens Enterprise Communications GmbH & Co. KG is a trademark licensee of Siemens AG

57

Page 58: Mod08 Amos

58

AMOsSiemens

EN4401EN00EN_0014© Siemens Enterprise Communications GmbH & Co. KG 2011. All rights reserved.

Siemens Enterprise Communications GmbH & Co. KG is a trademark licensee of Siemens AG

Page 59: Mod08 Amos

AMOs Siemens

9 SBCSU - Station and S0 Bus Configuration of SWU

The AMO SBCSU configures terminal devices (stations) at S0 bus connections, S0 interfaces, Up0/E interfaces, IP interface and on the ATM switch. A maximum of one voice terminal may be assigned to an S0 bus. A maximum of three terminals with three different station numbers can be set up per Up0/E access. Apart from configuring stations, the AMO SBCSU offers the options of displaying, regenerating and changing the associated data, as well as cancelling sta-tion assignments.

The AMO SBCSU assigns all station combinations which contain the following terminals. All other station combinations are assigned with the aid of the AMOs SCSU or SSCSU.

● The following terminals are configured for the VOICE service:

– OPTISET: Digital telephone for Up0/E interface and CorNet-TS protocol

– OPTIP500: Digital telephone for Up0/E interface and CorNet-TS protocol

– OPTIIP: Digital telephone for IP interface and CorNet-TS protocol

– SET600: Digital telephone for S0 interface and EDSS1 (EURO-ISDN) or NI-BRI protocol

– ANADEV: Analog voice terminal(connected to Up0/E via terminal adapter a/b)

– Terminal equipment for Cordless Multicell Integration (CMI Version >= V2.2):BASE: CMI base station with Up0/E interface and CorNet-TS protocolRADIO: CMI mobile user with Up0/E interface and CorNet-TS protocolEXTLINE: CMI Extension connection with S0 interface and EDSS1 (EURO-ISDN) pro-tocol

– Voice terminal equipment with SIP or S0 or S2 interfaces

● The following terminals are configured for non-voice services only:

– API: Workstation protocol interface and CorNet protocol (DATA service)

– ANADEV: analog non-voice terminal (DTE and FAX)(connected to Up0/E via terminal adapter a/b)

● DTE:

– digital DTE with S0 interface, EDSS1 (EURO-ISDN) protocol

– digital DTE with U2B1Q interface, NI-BRI protocol

– digital DTE with V.24 interface (connected via terminal adapter), EDSS1 (EURO-ISDN) protocol

EN4401EN00EN_0014© Siemens Enterprise Communications GmbH & Co. KG 2011. All rights reserved.Siemens Enterprise Communications GmbH & Co. KG is a trademark licensee of Siemens AG

59

Page 60: Mod08 Amos

60

AMOsSiemens

– digital DTE with U2B1Q interface (connected via terminal adapter),NI-BRI protocol

– analog DTE (connected to S0 via terminal adapter a/b and modem)

● FAX:

– Group 2 and 3 (connected to S0 via terminal adapter a/b)

– Group 4, EDSS1 (EURO-ISDN) or NI-BRI??? protocol

● Non-voice terminal equipment with S0 or S2 interfaces, e.g. DP systems, LANs, Servers.

The type of non-voice terminal equipment for DTE and FAX connected to S0 (analog, digital S0, digital X.21) is not taken into account for the purpose of assignment in this AMO. In addition to the terminal name, only the protocol type parameter DPROT resp. FPROT must be declared. The terminal attributes, which are not relevant for assignment purposes, are determined when the terminal first responds to a polling message at the bus connection or the station line circuit.

The terminals are assigned to the following modules:SLMS (S0 interface) (to Hicom H V1.0)

STMD (S0 interface) (to Hicom H V1.0)

STMD2, STMD3 (S0 interface)

DIU-N2, DIU-N4 (S2 interface)

DIU-S2 (S2 interface)

SLMQ (ANSI-U interface)In the case of extremely long lines (from 1-2 km up to 9 km)

SLMQ3 (U2B1Q interface)

SLC16 / SLC24 (Up0/E interface)

SLMO, SLMO16, SLMO24, SLMOP, SLOP2

(Up0/E interface)

STHC, STHC2 (combination of STMD and SLMO, i.e. S0 as well as Up0/E interface)

STMA (IWU to the ATM switch)

STMI-HFA (HFA gateway version 1 to IP)

STMI2, STMI4 (HFA gateway version 2 to IP)

EN4401EN00EN_0014© Siemens Enterprise Communications GmbH & Co. KG 2011. All rights reserved.

Siemens Enterprise Communications GmbH & Co. KG is a trademark licensee of Siemens AG

Page 61: Mod08 Amos

AMOs Siemens

Functions

● ADD Configuring the static and dynamic memories in the CC and the LTGs for the above-described device combinations as well as entering the static device data

● CHANGE Changing the static device data .

● DELETE Deleting specific service assignments or an entire station configura-tion

● DISPLAY Interrogating existing station configurations

● REGENERATE Regenerating existing station configurations

EN4401EN00EN_0014© Siemens Enterprise Communications GmbH & Co. KG 2011. All rights reserved.Siemens Enterprise Communications GmbH & Co. KG is a trademark licensee of Siemens AG

61

Page 62: Mod08 Amos

62

AMOsSiemens

EN4401EN00EN_0014© Siemens Enterprise Communications GmbH & Co. KG 2011. All rights reserved.

Siemens Enterprise Communications GmbH & Co. KG is a trademark licensee of Siemens AG

Page 63: Mod08 Amos

AMOs Siemens

10 SCSU - Subscriber Configuration of Switching Unit

AMO SCSU is used to configure ports for the connection of the following terminals:

● ANATE to SLMA, SLMA2, SLMA3, SLMA24, SLMAB, SLMAR, SLMAC, SLMAE

● Charge Metering ANATE (ANATECM) to SLMAR

● AUXDIGI to SLMB, SLMB4

The digital terminals at S0/Up0/UpoE such as SET600/OPTISET/OPTIP500 are set up using AMO SBCSU.

Special subscribers (e.g. Hicom Trading Board subscribers) are configured by AMO SSCSU.

Each STN number can be assigned personalized data such as names or personal identification numbers (PIN) using AMO PERSI.

AMO TGER is used to assign additional station numbers to non-voice terminals which have al-ready been assigned a number (AMO SCSU/SBCSU).

It is also possible to configure "virtual" ports for all device types which have not been assigned to a module but are configured in the same way as regular physical ports. Virtual ports are iden-tified as INS=FLOAT or INS=ACLSTN. These ports are used by any ID card user who identifies himself at another terminal by inserting his ID card or by keying in the PIN, and who then makes the call using the features of his virtual port such as classmarks, speed dialing digit series etc.. An ANATECM is not allowed to be configured as virtual port.

It is also possible to install a signed off fictive station by depicting INS=SIGNOFF. A signed off station can only be an ANATE. Signed off stations can be signed on

● by entering a PIN-Number and a key number at the specific terminal or

● by being signed on terminal by means of service staff

● by administration command (AMO DSSU)

Signed off stations can be added to communication groups such as pick up groups, hunting groups etc. This allows a complete preconfiguration of subscribers.

For "virtual" ports (e.g. INS=FLOAT) PEN-specific parameters (e.g. COFIDX) are ignored.

A suffix-dialing connection is required for connecting special facilities such as VMX servers. This connection is identified as SPEC=SUFDIAL and parameterized using the parameter DH-PAR.

For special stations (e.g. COMTEL) and for special country specific adaptions in SLMA1/SLMA2/SLMA3/SLMA24/SLMAB/SLMAR-Loadware parameterization can be done by using parameter DHPAR.

Some special subscribers like Voice Pagers etc. are configured using parameter SPEC.

EN4401EN00EN_0014© Siemens Enterprise Communications GmbH & Co. KG 2011. All rights reserved.Siemens Enterprise Communications GmbH & Co. KG is a trademark licensee of Siemens AG

63

Page 64: Mod08 Amos

64

AMOsSiemens

Functions

● ADD Configuring the static and dynamic memories in the CC and the LTGs for the above-described device combinations as well as entering the static device data

● CHANGE Changing the static device data .

● DELETE Deleting specific service assignments or an entire station configura-tion

● DISPLAY Interrogating existing station configurations

● REGENERATE Regenerating existing station configurations

EN4401EN00EN_0014© Siemens Enterprise Communications GmbH & Co. KG 2011. All rights reserved.

Siemens Enterprise Communications GmbH & Co. KG is a trademark licensee of Siemens AG

Page 65: Mod08 Amos

AMOs Siemens

11 Configuration of a Subscriber

11.1 UP0/E - subscriber

Configuration of an optiPoint 500 subscriber with a description of the parameter and cross ref-erences to the related AMOs.

New subscriber number:Related AMO: WABEDAR=STN has to be reserved (R), destinationnumber (DESTNO) = 0

PEN:optional parameter, system is using thenext free PEN of a SLMO24/SLMOP, if theparameter PEN isn’t used. Related AMO: BCSU/SDSU

EN4401EN00EN_0014© Siemens Enterprise Communications GmbH & Co. KG 2011. All rights reserved.Siemens Enterprise Communications GmbH & Co. KG is a trademark licensee of Siemens AG

65

Page 66: Mod08 Amos

66

AMOsSiemens

Authorizations (COS)- and LCR-Authorizations (LCOS) classesLCOSV for service voiceLCOSD for service data1 for day authorization2 for night authorizationRelated AMOs:- for content:COSSU, SDAT- for LCR:LDPLN, LDAT

DPLN-group 0-15Standard=0Related AMO:WABE

ITR-group 0-15Standard=0Related AMO:VBZ

Secret station numberIf “yes” is selected, the setting of the AMOZAND instead of PERSI is used.Related AMOs:ZAND: ALLDATA2, DISPNUUM=XXXIf ONLYEXT is selected, it is possible to trans-mit an other number instead of the extensionnumber.Related AMO:KNMAT: MODCON=REPEXT

COSX-group 0-15Standard=0Related AMOs:BERUM, BERUZ for switchingFEASU: COSXCD, COSXDB, COSXKEY,COSXATND, COSXTWABE: DAR ACOSX/DCOSXPERSI: PIN for COPIN 7 for the STN

Speed Calling Individual0, 10, 20, 30 destinationsRelated AMOs:DIMSU: SPDIFEASU: SPDIWABE: KZP=SPDI and SPDIPROGZIEL

Central speed calling lists: 0-15SPDC1: table 1SPDC2: table 2“16” code for deletingRelated AMOs:LRNGZ, ZRNGZDIMSU: SPDCL, SPDCDFEASU: SPDCWABE: DAR SPDC1, SPDC2

EN4401EN00EN_0014© Siemens Enterprise Communications GmbH & Co. KG 2011. All rights reserved.

Siemens Enterprise Communications GmbH & Co. KG is a trademark licensee of Siemens AG

Page 67: Mod08 Amos

AMOs Siemens

IDCRStation with identity card reader

Key layout standardStandard=0-127Related AMO:TAPRO

SecretarySubscriber is secretary of a “CHESE”executive-secretary groupRelated AMO:CHESE

Number of add-on devicesdependent of the device: 0-4

Station in serviceyes/no or signed off (no PEN is used)

Alarm number0: no alarm assigned8-519: number of directional alarm group520-583: number of personal alarm groupRelated AMOs:VADSU

Reject call back on busyAttention to parameter CBKBMAX in AMOSBCSU.

Related AMOs:FEASU: CBK, DCBB, DCBNOAZAND: ALLDATA, CBKNO(number of callbacks for a STN activated incase of busy or no answer)

Reject call back on no answerAttention to parameter CBKBMAX in AMOSBCSU.

Related AMOs:FEASU: CBK, DCBB, DCBNOAZAND: ALLDATA, CBKNO(number of callbacks for a STN activated incase of busy or no answer)

Max. number of callback1-5 or 99Attention to parameter RCBKB in AMO SBCSU Related AMOs:FEASU: CBK, DCBB, DCBNOAZAND: ALLDATA, CBKNO(number of callbacks for a STN activated incase of busy or no answer)

EN4401EN00EN_0014© Siemens Enterprise Communications GmbH & Co. KG 2011. All rights reserved.Siemens Enterprise Communications GmbH & Co. KG is a trademark licensee of Siemens AG

67

Page 68: Mod08 Amos

68

AMOsSiemens

HeadsetWITHIND Headset with HW indicationNOIND: Headset without HW indicationAttention to parameter HSKEY in AMO SBCSU

Function of the HS key (Head set key)NORMAL: HS key must be used for answerHSGIND: HS key for indication of the head setRelated AMO:TAPRO

Text selector for display

Related AMOs:ZAND: ALLDATA2, TEXTSELIn ACTIVE TEXTSEL up to 5 languages can beselected.An user should select the language with a key:TAPRO: key LANSELSDAT: Attribute LNGDYN or LNGSTAT

Callback on no answer is stored in the mail-boxAttention to parameter RCBKNA in AMO SBC-SU

Related AMOs:FEASU: CBK, DCBB, DCBNOAZAND: ALLDATA, CBKNO

EN4401EN00EN_0014© Siemens Enterprise Communications GmbH & Co. KG 2011. All rights reserved.

Siemens Enterprise Communications GmbH & Co. KG is a trademark licensee of Siemens AG

Page 69: Mod08 Amos

AMOs Siemens

11.2 Configuration of an IP subscriber

An IP-device like e.g. optiPoint 400, optiPoint 410, optiPoint 420 and optiPoint 600 will be con-figured in principle like a UP0/E subscriber. Additional resp. other parameters will be shown in the next part.

IP: connected to a STMIIP2: connected to a STMI2

Password for IP login procedure.

Codec, used by the ResourceManager.

EN4401EN00EN_0014© Siemens Enterprise Communications GmbH & Co. KG 2011. All rights reserved.Siemens Enterprise Communications GmbH & Co. KG is a trademark licensee of Siemens AG

69

Page 70: Mod08 Amos

70

AMOsSiemens

11.3 Deletion of a Subscriber

EN4401EN00EN_0014© Siemens Enterprise Communications GmbH & Co. KG 2011. All rights reserved.

Siemens Enterprise Communications GmbH & Co. KG is a trademark licensee of Siemens AG

Page 71: Mod08 Amos

AMOs Siemens

12 SDAT - Administration of Individual Subscriber Attributes and General Subscriber Data

The AMO SDAT can be used to administer subscriber-related attributes and features for the voice service. It can process subscribers who have been added with the AMO SCSU, SBCSU, or SBCSU.

It can also be used to administer general data that is independent of any particular device.

12.1 CHANGE-SDAT

12.1.1 Changing Attributes / Features

When attributes are changed (added / removed), compatibility checks are carried out to test the following:

a) whether the attributes entered - or those already existing - are compatible with each other,

b) whether the attributes entered are compatible with the type of equipment belonging to the subscriber,

c) whether the attributes entered are compatible with special subscriber data

When attributes are added for ACD SUPERVISOR a check is carried out to establish whether there are sufficient purchased subscribers of this type.

When an ACD attribute is removed, a check is carried out to establish whether there are still ACD group relationships.

12.1.2 Changing General Subscriber Data (Branch DATA)

In this branch, it is possible to change general subscriber data that is independent of any device. This data consists of parameters that are processed in the AMO SBCSU and in the AMO SCSU and SSCSU.The checks correspond to the checks in the AMO with which the subscriber being changed was added.

12.1.3 Changing Subscriber Data (Branch DATA1)

In this branch, it is possible to change additional subscriber data. This data consists of param-eters that are processed with AMO SDAT only. AMO SBCSU, SCSU and SSCSU can not pro-cess this data.

EN4401EN00EN_0014© Siemens Enterprise Communications GmbH & Co. KG 2011. All rights reserved.Siemens Enterprise Communications GmbH & Co. KG is a trademark licensee of Siemens AG

71

Page 72: Mod08 Amos

72

AMOsSiemens

12.2 DELETE-SDAT

The action DELETE-SDAT can be used to delete specific subscriber attributes which were con-figured with CHANGE-SDAT, TYPE=DATA1.

PUBNUM

When deleting PUBNUM the parameters TON and NPI are deleted, too.

12.3 DISPLAY-SDAT

The action DISPLAY-SDAT results in the following:

1. In the branch SUBDATAthe general subscriber data and the subscriber-related attributes / features of a subscriber are output in tabular form.

2. In the branch SUBFINDsubscribers with a particular subscriber-related attribute / feature are output in tabular form.

3. In the branch SUBOVthe assigned device and the AMO used to add the subscriber are output in tabular form for the subscribers entered.

4. In the branch NNOFINDsubscribers with a particular NNO are output in tabular form.

12.4 REGENERATE-SDAT

The action REGENERATE-SDAT can be used to restrict the output to subscribers with particular subscriber-related attributes / features.

EN4401EN00EN_0014© Siemens Enterprise Communications GmbH & Co. KG 2011. All rights reserved.

Siemens Enterprise Communications GmbH & Co. KG is a trademark licensee of Siemens AG

Page 73: Mod08 Amos

AMOs Siemens

13 BERUM - Class of Service Switchover

Stations are allocated two classes of service (COS1 and COS2) in (COS1 = normal or day COS COS2 = alternative or night COS) in their line tables.The class of service are maintained by AMO COSSU and assigned to stations with the AMOs SCSU and SBCSU.An identifier (COS pointer) in the line tables indicates which COS is active.

AMO SCSU and AMO SBCSU subdivides the stations into COS switchover groups (COSX groups). This is performed in order to group stations so that a certain COS can be switched active for all of them.If no specific allocation has been made, a station belongs to COSX group 00. Stations with an active key switch (KEYSTN) are not changed over, but they are still assigned to a COSX group. The COSX groups are independent of other station groups formed on the basis of other fea-tures.

Switchover between the two classes of service can be performed from a station, from an atten-dant console, centrally using the AMO, via data channel and/or by means of a timed switchover.

a) COS Switchover from the Station

A station authorized for this type of switchover can switch over between the COSs us-ing the personal ID number (PIN) and a code for switchover using an active key switch (KEYSTN). As long as the alternative COS (COS2) is active, the user hears the special dial tone when he lifts the receiver. The station is assigned the authorization COSXCD (COS switchover by code) by AMO COSSU in order to be able to perform a switchover using the PIN. The PIN (maximum of 12 digits) is defined by the AMO PERSI.

b) COS Switchover from the Attendant Console (ATND)

Switchover of the normal COS of the COSX groups to an alternative COS can be per-formed from every attendant console, including the night attendant console (performed with the task BEZUM).

c) COS Switchover by AMO

COS switchover for COSX groups of stations can be performed using the AMO BERUM.

d) COS switchover using a data processing system (DVA) is implemented via a data channel.

EN4401EN00EN_0014© Siemens Enterprise Communications GmbH & Co. KG 2011. All rights reserved.Siemens Enterprise Communications GmbH & Co. KG is a trademark licensee of Siemens AG

73

Page 74: Mod08 Amos

74

AMOsSiemens

e) Automatic COS Switchover

The COS switchover for COSX groups can be carried out automatically at a specific, definable time. This time is defined using the AMO BERUZ (time table for times at which class of service switchover is to occur). Switchover is carried out by the task BEZUM.

Priorities for COS Switchover

The last COS switchover performed for a station is always in effect, regardless of where this change was carried out (from the station, from the attendant console or automatically).

Function:

CHANGE-BERUM;

DISPLAY-BERUM:

EN4401EN00EN_0014© Siemens Enterprise Communications GmbH & Co. KG 2011. All rights reserved.

Siemens Enterprise Communications GmbH & Co. KG is a trademark licensee of Siemens AG

Page 75: Mod08 Amos

AMOs Siemens

14 BERUZ - Times at which Class of Service Switchover is to Occur

Stations (configured by AMO SCSU and AMO SBCSU) are allocated two classes of service COS1 and COS2) in their line tables. A class of service contains the authorizations of a station. An identifier (COS pointer) in the line tables indicates which COS is active, i.e. which of the sta-tion’s authorizations are currently activated; this is usually COS1. AMO SCSU and AMO SBCSU subdivides stations into COS switchover groups. This is per-formed in order to group stations so that a certain COS can be switched active for all of them. The COSX groups are independent of other station groups formed by other features. If no specific allocation has been made, a station belongs to COSX group 0. Stations with an active key switch (KEYSTN) are not switched over, but they are still assigned to a COSX group.

The classes of service can be switched over from a station, from an attendant console, y means of AMO BERUM, via data channel, and/or by means of a timed switchover.

Switchover at a fixed Time (timed Switchover) A table is created in the database, in which the following data is entered for each day of the week and for each COS switchover group:

● A time at which COS1 is switched to active (COS1T),

● A time at which COS2 is switched to active (COS2T),

● A program switch indicating whether the displayed switchover to COS1 is to be carried out on that day (COS1),

● A program switch indicating whether the displayed switchover to COS2 is to be carried out on that day (COS2).

AMO BERUZ administrates this table. (The switchover is carried out with the task BEZUM.)

MON(1) TUE(2) WED(3) THU(4) FRI(5) SAT(6) SUN(7)

COSX 006.5515.40off/on

06.5515.40off/on

06.5515.40on/on

06.5515.40on/on

06.5515.40on/on

00.0000.00off/off

00.0000.00off/off

COSX 106.5515.40on/on

06.5515.40on/on

06.5515.40on/on

06.5515.40on/on

06.5515.40on/on

00.0012.00on/on

00.0012.00off/off

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

COSX1500.0000.00off/off

00.0000.00off/off

00.0000.00off/off

00.0000.00off/off

00.0000.00off/off

00.0000.00off/off

00.0000.00off/off

(COSX = Class of service switchover group)

Table 14-1

EN4401EN00EN_0014© Siemens Enterprise Communications GmbH & Co. KG 2011. All rights reserved.Siemens Enterprise Communications GmbH & Co. KG is a trademark licensee of Siemens AG

75

Page 76: Mod08 Amos

76

AMOsSiemens

Function:

ADD-BERUZ:

DISPLAY-BERUZ:

REGENERATE-BERUZ:

EN4401EN00EN_0014© Siemens Enterprise Communications GmbH & Co. KG 2011. All rights reserved.

Siemens Enterprise Communications GmbH & Co. KG is a trademark licensee of Siemens AG

Page 77: Mod08 Amos

AMOs Siemens

15 ZIEL - Destination Addresses for Stations

This AMO is used to enter, interrogate or regenerate destinations in the database (DB) for the following features:

● Call forwarding - fixed (FWD)

● Messenger Call (MSGR)

● Direct station select keys (DSS)

● Name/repertory key (NAME)

● Individual speed dialling (SPDI)

● Saved Number Redial (SNR)

● Attendant Console Direct Destination Select keys (DDS)

● Destinations for the BUZZ Feature

AMO-ZIEL is also used to add, delete, interrogate or regenerate for:

● dialing external servers to deposit messages

● identifying external servers when retrieving messages with the START key

Call forwarding - fixed

Two forwarding variants are possible:

● STATION forwarding can be added or deleted by AMO ZIEL or by the subscriber, and activated or deactivated by the subscriber or by AMO ACTDA.

● SYSTEM forwarding is a new forwarding typeAdding and deleting destinations is only possible by AMO ZIEL, whereby different destina-tions can be entered for different forwarding types (eg.busy, no response), immaterial, if the incoming call is internal or external. The forwarding can be activated or deactivated by AMO ACTDA, or by the subscriber using the relevant codes.

● Call forwarding on no responseThe fixed call forwarding destinations do not act ad destinations for call forwarding on no response any more. These can be added as fixed destinations for forwarding type CFNR (no response) or CFB (busy) in the SYSTEM forwarding (AMO ZIEL), and activated by AMOACTDA, or can be added and activated as variable forwarding (CFNR or CFB) (AMO ACTDA).

EN4401EN00EN_0014© Siemens Enterprise Communications GmbH & Co. KG 2011. All rights reserved.Siemens Enterprise Communications GmbH & Co. KG is a trademark licensee of Siemens AG

77

Page 78: Mod08 Amos

78

AMOsSiemens

Fixed destinations can be created for each service. This AMO however does not activate or de-activate forwarding. Destinations can be entered in the services VCE (voice), FAX and DTE. Destinations for devices working to the DSS1 protocol can only be activated as variable for-warding destinations by AMO ACTDA.Destinations can be entered for all created STNOs (station numbers) with the exception of at-tendant terminals, irrespective of whether or not the station concerned has any terminal devic-es.

The following diversion types can be used:

for SYSTEM forwarding

● CFU (Call Forward Unconditional)

● CFB (Call Forward Busy)

● CFNR (Call Forward No Reply)

● CFDND (Call Forward Do Not Disturb)

for STATION forwarding

● CFU (Call Forward Unconditional)

Messenger Call

The members of an integrated executive/secretary system can have a messenger call key on their voice terminal for which a fixed destination can be entered. This destination can also be pro-grammed at the administration and maintenance terminal. Only analog stations are permitted.

Direct station select keys

Direct station select (DSS) keys can be assigned to all terminals. The key functions for OPTISET and Optipoint 500 are defined with the help of the AMO TAPRO. Only internal destinations are possible (analog telephone, digital voice terminal, and personal attendant call number). In addition to entering the destination in the database, the AMO ZIEL also enters partner infor-mation for the destination station (controls the lamps in the DSS key).

Name/repertory key

The key functions for the OPTISET and Optipoint 500 are defined with the help of the AMO TAPRO. Destinations can only be entered after the key functions have been defined. The des-tination entry may be any combination of digits comprising a maximum of 22 characters. Destination entries may be protected against changing and deleting by the destination terminal user, using parameter PROTECT=YES. Changing or deleting by AMO will be possible further-more.Name/repertory keys of OPTISET / Optipoint 500 add on terminals have two levels to store des-tination entries. A level can be selected by entering a value for parameter LEVEL.

EN4401EN00EN_0014© Siemens Enterprise Communications GmbH & Co. KG 2011. All rights reserved.

Siemens Enterprise Communications GmbH & Co. KG is a trademark licensee of Siemens AG

Page 79: Mod08 Amos

AMOs Siemens

Individual speed dialling

Stations that are permitted to use the SPDI are provided an SPDI list when created by means of AMO SBCSU. Stations with an analog telephone, a voice terminal, mobile users (without a device, but with a separate terminal connection), and DTE stations may use the SPDI. Voice terminals can also used name/repertory keys and DSS keys.

Saved Number Redial

Each analog telephone and voice terminal can store a dialed number with up to 22 digits for redial. The destination can be any combination of digits (0-9,*,#,A,B,C,D).

Attendant Console Direct Destination Select keys

Each attendant console has 42 destination (DDS) keys

● 40 destinations via the destination keys

● 2 destinations via R1, R2 keys (trunk group keys for reserving lines).

The destinations are entered into a storage area that can hold up to 42 The configuration is carried out when the attendant console is created by means of AMO AC-SU. The destination keys write memory locations 1-40, while the trunk group keys R1 and R2 are always defined at locations 41 and 42.

Destinations for the BUZZ Feature

The buzz feature allows a user to alert (buzz) a predefined keyset or DFT (optiset and optiPoint 500) by pressing the BUZZ key or by keying an access code. Voice communication is not pos-sible. Buzz causes the target keyset or DFT to be alerted and the originator’s station number to be displayed for two seconds. The buzz target (destination) and the originator must be locat-ed in the same node.

EN4401EN00EN_0014© Siemens Enterprise Communications GmbH & Co. KG 2011. All rights reserved.Siemens Enterprise Communications GmbH & Co. KG is a trademark licensee of Siemens AG

79

Page 80: Mod08 Amos

80

AMOsSiemens

15.1 ADD-ZIEL

Example

A fixed call forwarding destination for diversion type CFNR to STNO 3101 for the VOICE service can be created for voice station 2100.

Input:

ADD-ZIEL:TYPE=FWD,SRCNO=2100,SI=VCE,DESTNOF=3101,DTYPE=CFNR,ITYPE=GEN,CFVAR=SYSTEM;

15.2 DISPLAY-ZIEL

Example

Interrogate the call forwarding destination for station 2100.

Input:

DISPLAY-ZIEL:TYPE=FWD,SRCNO=2100;

Output:

FWD SOURCE | SERVICE | DTYPE | ITYPE | CFVAR | DESTINATION -------+----------+-------+---------+---------+----------------------- 2100 | VCE | CFU | INT | SYSTEM | 3140

15.3 REGENERATE-ZIEL

Example

Regenerate the call forwarding destination for station 2100.

Input:

REGENERATE-ZIEL:TYPE=FWD,SRCNO=2100;

Output

ADD-ZIEL :FWD,2100,VCE,2100,VCE,3101,,CFNR,GEN,SYSTEM;

EN4401EN00EN_0014© Siemens Enterprise Communications GmbH & Co. KG 2011. All rights reserved.

Siemens Enterprise Communications GmbH & Co. KG is a trademark licensee of Siemens AG

Page 81: Mod08 Amos

AMOs Siemens

16 ACTDA - Activation of User Features

The AMO ACTDA is used to regenerate feature-specific data entered by a user via the terminal. The functions DISPLAY, REGENERATE, ADD and DELETE are implemented. The AMO en-ables these data to be saved while the software version (APS) is being changed.

Using the DISPLAY function, the user data recorded by ACTDA can be displayed on the admin-istration and maintenance terminal.

A command batch is generated with the REGENERATE function, based on the user data. This command batch is used for reinitializing the database.

The ADD function initializes the database with the user data.

The AMO ACTDA is used mainly for regenerating data. In addition, it can be used for test pur-poses.

In special cases it can be necessary to deactivate the activated call forwarding of a station. This function has been implemented in the branch DELETE.

TYPE Feature

STN DND Do-not-disturb

FWD Fixed call forwarding

Variable call forwarding

OPTISET individual optiset E / optipoint 500 settings

OUTHUNT switch out of hunt group

RCUTOFF Ringer Cutoff

REMIND Timed reminder

REPSECR Deputy for secretary

RNGXFER Ring transfer

VCR Voice call rejection

ATNDGR NOPT Night variant for ATNDGR

ITR DNDGR Group do-not-disturb function

ISTR Controlled station-to-station restriction

Controlled station-to-station restriction for all ISTR groups

MOBHFA MLOGOFF Logoff of mobile hfa-user

MLOGON Logon of mobile hfa-user

EN4401EN00EN_0014© Siemens Enterprise Communications GmbH & Co. KG 2011. All rights reserved.Siemens Enterprise Communications GmbH & Co. KG is a trademark licensee of Siemens AG

81

Page 82: Mod08 Amos

82

AMOsSiemens

Some user data is already administrated by other AMOs. These data are not additionally ad-ministrated by ACTDA.

Function:

ADD-ACTDA:

DELETE-ACTDA:

DISPLAY-ACTDA:

REGENERATE-ACTDA:

AMO Feature-specific data

CHESE Secretarial transfer function destinations

ZIEL Individual speed dialing numbers

Call numbers for stored number redial

Name/repertory key data for DIGITEs

DSS (direct station selection) destinations

Messenger call destinations

Name/repertory key data for ATNDs

TAPRO Store key functions for DIGITEs

BERUM Data for class-of-service changeovers (individual, group, all)

EN4401EN00EN_0014© Siemens Enterprise Communications GmbH & Co. KG 2011. All rights reserved.

Siemens Enterprise Communications GmbH & Co. KG is a trademark licensee of Siemens AG

Page 83: Mod08 Amos

AMOs Siemens

17 PERSI - Personal Identification

The AMO PERSI is used to administer personal data. The cross-reference to the person is in-variably established via the station number.

a) NamesEach station number can be assigned either one or several (any number of) names; the name entered first will be displayed on DIGITE displays. All other names are used for ETD functions. The name can also be made up of 2 parts:

1. Surname, simple or composite, e.g. Hr. Meier, Fr. Dr. Huber

2. Name, and additional information, e.g. Anna, Dept. A3The characters of the "surname" are separated from those of the "name" by means of a "*".

Digite display: The DIGITE has a 24-character display. The type of display, e.g. station number plus name or name only is defined by means of AMO ZAND, TYPE=ALLDATA, DISPMODE-MODE1 to MODE5 (see examples). There is no verification of the last name. The number of blanks between the station number and the name is exactly one.

Examples

Input: Dr. v. Ritter*MartinDisplayMODE1: 32857 DR. V. RITTER M.MODE2: 32857MODE3: DR. V. RITTER MARTINMODE4: DR. V. RITTERMODE5: # DR. V. RITTER

b) Organizational unitEach name can be assigned an organizational unit (for ETD functions).If a station number has not been assigned a name, no org. unit can be assigned.If station number has been assigned several names, but not everyone of these names has been assigned an organizational unit, the organizational unit which was assigned last is automatically assigned to the remaining names.

c) Personal identification number (PIN)The PIN is used for personal identification of a person to the system. Each station number can be assigned any number of PINs. The length of a particular PIN type is determined centrally. The PIN length may or may not be the same for the types of PINs described above. Each PIN (except COSXCD) must be unique throughout the system.

EN4401EN00EN_0014© Siemens Enterprise Communications GmbH & Co. KG 2011. All rights reserved.Siemens Enterprise Communications GmbH & Co. KG is a trademark licensee of Siemens AG

83

Page 84: Mod08 Amos

84

AMOsSiemens

The "class of PIN" (COPIN) is used for each PIN type in order to implement the PIN display feature and in order to distinguish between the different PIN types.The characteristics of the COPINs (1 through 15) are summarized in the so-called COPIN table in which the following default values are assigned to the type of PIN:

Function:

ADD-PERSI:

CHANGE-PERSI:

DELETE-PERSI:

DISPLAY-PERSI:

REGENERATE-PERSI

PINTYPE(COPIN)

PIN COTYPE PIN Meaning of a type of PIN

1 = PIN1 MOBILE Manual identification2 = PIN2 BUSLONG Identification of business calls (remains active until

manual deletion or timeout).3 = PIN3 BUSSHRT Identification of business calls4 = PIN4 PRIVSHRT Identification of private calls5 = PIN5 PCODE Identification of a project for a call (project code =

PCODE).6 = PINC PINCARD Identification by means of a magnetic/chip card which is

inserted into the card reader of the terminal.7 = COSXCD COSXCD Identification of users which are authorized to activate

COS changeover from the terminal.8 = SI SI Pin for service id9 = CDRAC PCODE CDR account code10 = PIN10 PCODE PIN for dialing pattern check11 = PIN11 MOBILE Manual identification12 = PIN12 MOBILE Manual identification13 = PIN13 MOBILE Manual identification14 = PIN14 MOBILE Manual identification15 = PIN15 MOBILE Manual identification

EN4401EN00EN_0014© Siemens Enterprise Communications GmbH & Co. KG 2011. All rights reserved.

Siemens Enterprise Communications GmbH & Co. KG is a trademark licensee of Siemens AG

Page 85: Mod08 Amos

AMOs Siemens

18 LRNGZ - List of Central Speed Dialing Numbers

The central speed dialing facility (SPDC) is used to simplify dialing. Long call numbers (desti-nation numbers) - usually external numbers - can be transmitted by means of a speed dialing number.

The allocation of speed dialing numbers to destination numbers is stored in the central speed dialing lists.

Up to 16 of these lists (0 to 15) can be set up, each with a maximum of 1000 speed dialing num-bers.

Each user can access up to 2 of these lists, which are allocated to him with parameters SPDC1 (List 1) and SPDC2 (LIST 2) of a subscriber AMO (e.g. AMO SCSU or SBCSU).

The AMO LRNGZ is used to set up the lists and to allocate speed dialing numbers to each of them. The allocation of destination numbers is carried out using AMO ZRNGZ.

The SPDC feature is accessed by dialing a code following the speed dialing number.

There are two versions of access.

a) Access of both lists via only one dialing code (digit analysis result SPDC1 in AMO WABE).

In this case the speed dialing numbers of the lists, allocated to the user (parameter SPDC1 and SPDC2 of the subscriber AMO) must be different, since it is the speed di-aling number which determines whether the 1st or 2nd list is dialed. The administrator of the switch has to take care of the so called „unambiguousness“ of the speed dialing number ranges. Because of the various combinations of speed dialing lists, allocated to the users (any two lists out of the available lists 0 to 15 can be allocated to any user), AMO LRNGZ is not able to check the unambiguousness.

In the case of 3 digit speed dialing numbers a user can access a maximum speed di-aling number range of 000 to 999, divided over the two allocated lists. Therefore with this version of access a user has access to maximum 1000 speed dialing numbers.

b) Access of both lists via 2 dialing codes (digit analysis results SPDC1 and SPDC2 in AMO WABE). Via dialing code of digit analysis result SPDC1, the user has access to the 1st list, allocated to the user (parameter SPDC1 of the subscriber AMO) and via dialing code of SPDC2 to the 2nd list (parameter SPDC2 of the subscriber AMO)

In this case the speed dialing numbers of the lists, allocated to the user can be the same, i.e. the speed dialing number ranges can overlap, since the Lists are accessed via the dialing code (digit analysis results SPDC1 and SPDC2 in AMO WABE) and not via the speed dialing number.

EN4401EN00EN_0014© Siemens Enterprise Communications GmbH & Co. KG 2011. All rights reserved.Siemens Enterprise Communications GmbH & Co. KG is a trademark licensee of Siemens AG

85

Page 86: Mod08 Amos

86

AMOsSiemens

In the case of 3 digit speed dialing numbers a user can access a maximum speed di-aling number range of 000 to 999 per list. Therefore with this version of access a user has access to maximum 2000 speed dialing numbers.

The AMO DIMSU is used to establish how many lists (parameter SPDCL) and destinations (pa-rameter SPDCD) can be set up in the system.

Function:

ADD-LRNGZ:

CHANGE-LRNGZ:

DELETE-LRNGZ:

DISPLAY-LRNGZ:

REGENERATE-LRNGZ

EN4401EN00EN_0014© Siemens Enterprise Communications GmbH & Co. KG 2011. All rights reserved.

Siemens Enterprise Communications GmbH & Co. KG is a trademark licensee of Siemens AG

Page 87: Mod08 Amos

AMOs Siemens

19 ZRNGZ - Central Speed Calling Digit Series

The central automatic dialer is a memory area of abbreviated numbers which is distributed among several lists. All system subscribers can access a maximum of two lists each.The speed dialing lists are created by AMO LRNGZ.

An abbreviated number is used to simplify dialing. Each abbreviated number can be assigned an unabbreviated number. The number of suffix dialing digits describes the number of digits in the unabbreviated number which are to be transmitted with a time lag during automatic suffix dialing.

DISPLAY-ZRNGZ:TYPE=SPDNO,LST=00,SPDNO=00&&49;

Output:

LST: 00 KRN-BEREICH: 00 BIS 49

KRN LRN NAWA NAME

00 00897221 ............1 .......SIEMENS MUENCHEN

02 003432564738 ... ..0 .......SPANIEN

03 0613111515 ..... ....0 .......KINODIENST MAINZ

Functions

● ADD

● DELETE

● DISPLAY

● REGENERATE

EN4401EN00EN_0014© Siemens Enterprise Communications GmbH & Co. KG 2011. All rights reserved.Siemens Enterprise Communications GmbH & Co. KG is a trademark licensee of Siemens AG

87

Page 88: Mod08 Amos

88

AMOsSiemens

EN4401EN00EN_0014© Siemens Enterprise Communications GmbH & Co. KG 2011. All rights reserved.

Siemens Enterprise Communications GmbH & Co. KG is a trademark licensee of Siemens AG

Page 89: Mod08 Amos

Abbreviation Siemens

Abbreviation

This table shows some important abbreviations.

Abbreviation Definition

AADP Administration Daten Processor AMC Administration and maintenance controlAMO Administration and maintenance OrganizationAPI Application Interface

CCC Common Control;CMI Cordless Multicell Integration COS Class of Service;

DDBAR Data Base Access Routine / Datenbasis ZugriffsroutineDEE Data Terminal Equipment / DatenendeinrichtungDSCXL Data and Switch Processor for CompactPCI/LANDSS Digital Subscriber Signalling 1

EEDSS1 European Digital Signalling System No1 (Europ. D-Kanal Protokol)

IISDN Integrated System Design Network/

Diensteintegrierendes digitales Nachrichtennetz

LLDU Logical Device Unit

MMMI Man Machine Interface (Mensch Maschine Schnittstelle)

OOS Operating System / Betriebssystem

QQSIG ECMA-Standard für die Signalisierung am Q-Referenzpunkt;

EN4401EN00EN_0014© Siemens Enterprise Communications GmbH & Co. KG 2011. All rights reserved.Siemens Enterprise Communications GmbH & Co. KG is a trademark licensee of Siemens AG

89

Page 90: Mod08 Amos

90

AbbreviationSiemens

SSIP Session Initiation ProtocolSWU Switching Unit (or new Common Control CC)

VVINET Virtual Networking

EN4401EN00EN_0014© Siemens Enterprise Communications GmbH & Co. KG 2011. All rights reserved.

Siemens Enterprise Communications GmbH & Co. KG is a trademark licensee of Siemens AG