2
MODEL TC-34 Gastight design Pump and motor are fully submerged in liquid minimizing loss and guaranteeing quick response pumping Vacuum jacketed sump provides extremely low heat leak—ideal pumping conditions (optional) Sealess and submerged design minimizes maintenance requirements Vertical pump design provides greater stability and longer life Special design VFD motor provides broad range of operation Use where product loss is not acceptable Liquid storage transfer Mobile delivery transfer – LAR, LN 2 Vehicle fueling stations – LNG Liquid nitrogen Liquid argon Methane (LNG) Vacuum jacketed sump Variable frequency drive Differential pressure gauge Loss of prime detector (cavitation protection) Safety relief valve Dual conduit box per NFPA standards for LNG service FEATURES & BENEFITS APPLICATIONS LIQUIDS PUMPED OPTIONAL ACCESSORIES * See back page for details SPECIFICATIONS Flow Range gpm 2 – 135 lpm 8 – 510 NPSHR feet 1.5 – 12 meters 0.5 – 4 Differential Head feet 50 – 1,600 meters 15 – 488 Pump Design Rating hp 10 up to 38 kw 7.5 up to 34 RPM Range* rpm 1,500 – 7,200 SUBMERGED MOTOR PUMP Not suitable for O 2 service
Transcript

Model TC-34

• Gastight design

• Pump and motor are fully submerged in liquid minimizing loss and guaranteeing quick response pumping

• Vacuum jacketed sump provides extremely low heat leak—ideal pumping conditions (optional)

• Sealess and submerged design minimizes maintenance requirements

• Vertical pump design provides greater stability and longer life

• Special design VFD motor provides broad range of operation

Use where product loss is not acceptable

• Liquid storage transfer

• Mobile delivery transfer – LAR, LN2

• Vehicle fueling stations – LNG

• Liquid nitrogen

• Liquid argon

• Methane (LNG)

• Vacuum jacketed sump

• Variable frequency drive

•Differentialpressuregauge

• Loss of prime detector (cavitation protection)

• Safety relief valve

• Dual conduit box per NFPA standards for LNG service

Features & BeneFits applications

liquids pumped

optional accessories

* See back page for details

speciFications

Flow Rangegpm 2 – 135

lpm 8 – 510

NPSHRfeet 1.5 – 12

meters 0.5 – 4

Differential Head

feet 50 – 1,600

meters 15 – 488

Pump Design Rating

hp 10 up to 38

kw 7.5 up to 34

RPM Range* rpm 1,500 – 7,200

SubMeRgeD MotoR PuMP

Not suitable for O2 service

Manufacturing

2321 S. Pullman Street Santa Ana, CA 92705 USATel 800.525.4216 (USA only)Tel +1.949.261.7533 • Fax [email protected] • www.acdcom.com

global service

north americaatlantaAtlanta, Georgia, USA+1 404.696.8113 • Fax +1 [email protected] • cryoindservice.com

california (acd service) Santa Ana, California, USA+1.714.568.0201 • Fax [email protected] • acdcom.com

houstonHouston, Texas, USA+1 281.590.4800 • Fax +1 [email protected] • cryoindservice.com

pittsburghImperial, Pennsylvania, USA+1 724.695.1910 • Fax +1 [email protected] • cryoindservice.com

red deerRed Deer, Alberta, Canada+1.403.352.4436 • Fax [email protected] • cryoindservice.com

torontoToronto, Ontario, Canada+1 416.502.1950 • Fax +1 [email protected] • cryoindservice.com

internationalaustraliaDandenong, Victoria, Australia+61.3.9791.7888 • Fax [email protected] • cryoquip.com

chinaHangzhou, China+86.571.8619.4799 • Fax [email protected] • cryoindservice.com

europe (acd crYo)CH-4142 Muenchenstein Switzerland+41.61.413.0230 • Fax: [email protected] • acdcryo.com

D-79415 Bad Bellingen Germany+49.7635.8105.0 • Fax: [email protected] • acdcryo.com

united arab emiratesJebel Ali Free Zone, Dubai, UAETel: [email protected] • acdcom.com

indiaA Division of Rhine Engineering Pvt. Ltd.Vadodara, Gujarat, India+91.265.283 0113 • Fax +91.265.283 [email protected] • acdcom.comKolkatta, West Bengal, India+91.973.216 [email protected] • acdcom.com

KoreaYongin-si, Gyeonggi-do, Korea+82.31.286.6114 • Fax [email protected] • cryoindservice.com

malaysiaShah Alam, Selangor D.Ehsan, Malaysia+60 (3) 5740.4800 • Fax +60 (3) [email protected] • cryoindservice.com

Bulletin No. ACD TC 34-R2.17© 2017 ACD LLC, Printed in USASPECIFICATIonS SUbJECT To CHAngE wITHoUT noTICE

Model TC-34

overall dimensions: SUCTIon bARREL MoUnTED

pump perFormance curve

• Pump and integral VFD designed motor with hermetically sealed lead through

•Mountingflangesformatingconnections• Junction box

tYpical scope oF supplY† Speed range – 1,500 to 6,000 rpm† † Speed range (KA) – 1,500 to 7,200 rpmNote: Consult factory for LNG/LN2/LAR pump speeds

550

490

425

365

305

245

185

120

60

0 20 40 60 80 100 120 140 160

Diff

eren

tial H

ead

– fe

et

Diff

eren

tial H

ead

– m

eter

s

200

400

600

800

1000

1600

1400

1800

1200

Flow Rate – lpm

75 155 230 310 390 470 550

Flow Rate – gpm

1x2x6-4 Stage†

1x2x6-2 Stage††

1.5x2.5x6-2 Stage†

Motor

1"– 300# Flange(Supplied by Customer)

Pass Thru Harness

ASME Code Vacuum JacketedPressure Vessel And Cover(Customer Supplied)

Vent1"–150#

Submersible

“Typical” InstallationDimensions

Suction2"–150#

13.7[348]

30.2[ 767]

37.5[953]

31.0[787]

8.9[226]

10.5[267]

inch/[mm]


Recommended