6
Home > Products > Pumps > MODEL VPF Site Map VERTICAL MIXED FLOW PUMP 30 Years MTBF (Mean Time Between Failures) 4 Years MTBO (Mean Time Between Overhaul) IMPELLER Stainless Steel/Duplex/Super Duplex SHAFT Stainless Steel/Duplex/Super Duplex CASING Cast iron/2%Ni Cast iron/Ni- Resist/Duplex/Super Duplex WEARING RING Stainless Steel/Duplex/Super Duplex Other material is also applicable like Monel, PEEK bearing, etc. Japanese
Transcript
Page 1: MODEL VPF VERTICAL MIXED FLOW PUMP - DMW · DMW's vertical mixed flow pumps, Model "VPF" are utilized in Irrigation, Drainage, ... There are hydraulic type and mechanical type for

Home > Products > Pumps > MODEL VPF Site Map

VERTICAL MIXED FLOW PUMP

30 Years MTBF (Mean Time Between Failures)

4 Years MTBO (Mean Time Between Overhaul)

IMPELLER Stainless Steel/Duplex/Super DuplexSHAFT Stainless Steel/Duplex/Super DuplexCASING Cast iron/2%Ni Cast iron/Ni-

Resist/Duplex/Super DuplexWEARING RING Stainless Steel/Duplex/Super Duplex

Other material is also applicable like Monel, PEEK bearing, etc.

Japanese

Page 2: MODEL VPF VERTICAL MIXED FLOW PUMP - DMW · DMW's vertical mixed flow pumps, Model "VPF" are utilized in Irrigation, Drainage, ... There are hydraulic type and mechanical type for

Home > Products > Pumps > MODEL VPF > Introduction Site Map

VERTICAL MIXED FLOW PUMP

DMW's vertical mixed flow pumps, Model "VPF" are utilized inIrrigation, Drainage, Sewage, Power Plant(CWP), Sea water vaporizerat LNG Receiving Terminal, Sea Water Intake at various plants, etc. We, DMW, can deliver highly-reliable pumps by design verificationand quality control represented by FEM, CFD, vibration analysis,sump model study and etc.

Japanese

Page 3: MODEL VPF VERTICAL MIXED FLOW PUMP - DMW · DMW's vertical mixed flow pumps, Model "VPF" are utilized in Irrigation, Drainage, ... There are hydraulic type and mechanical type for

Home > Products > Pumps > MODEL VPF > Explanation of Pump parts Site Map

VERTICAL MIXED FLOW PUMP

Japanese

Page 4: MODEL VPF VERTICAL MIXED FLOW PUMP - DMW · DMW's vertical mixed flow pumps, Model "VPF" are utilized in Irrigation, Drainage, ... There are hydraulic type and mechanical type for

Home > Products > Pumps > MODEL VPF > Pump type Site Map

VERTICAL MIXED FLOW PUMP

Pump type will be decided by following elements.・One floor type, Two floors type.・Non-pull-out type/Pull-out type/Rotor pull-out type.・Pump thrust:Supported by pump /by motor.・Fixed blade /Variable pitch blade

Pump type will be decided finally by considering following elements.・Comparison between costs of machinary and civil.・Relation between land condition and water intake level.・Way of maintenance.

Japanese

Page 5: MODEL VPF VERTICAL MIXED FLOW PUMP - DMW · DMW's vertical mixed flow pumps, Model "VPF" are utilized in Irrigation, Drainage, ... There are hydraulic type and mechanical type for

Home > Products > Pumps > MODEL VPF > Bearing design Site Map

VERTICAL MIXED FLOW PUMP

Thrust bearing will installed on either pump or motor.In case of thrust bearing being installed on pump, anti-friction bearing or tilting pad bearing will be used.

・ Self-contained oil lubricated antifriction bearing forstandard applications.

・Tilting pad thrust bearing for high thrustapplications.

Water filling is required at the first time of operation, also this bearing is used for submerged portion (bowl caseinternal).There are a lot of supply experiences and it is of high reliability.

Medium-lubricated, i.e. no lubricant supply system, no water pollution, no monitoring, no external piping,no valves,no filter.

Japanese

Page 6: MODEL VPF VERTICAL MIXED FLOW PUMP - DMW · DMW's vertical mixed flow pumps, Model "VPF" are utilized in Irrigation, Drainage, ... There are hydraulic type and mechanical type for

Home > Products > Pumps > MODEL VPF > Variable pitch blade pump Site Map

VERTICAL MIXED FLOW PUMP

By adjusting blade opening to infinite stage, water flow and head can be achivedand acordingly it makes energy-saving.There are hydraulic type and mechanical type for variable pitch blade pump.The pump can be started with impeller set at minimum opening, which faciliatesstarting with small starting torque.Operation near best efficiency point makes effective against cavitation.

H-Q curve, System curve "R",and B.H.P.curve "L" are shown asleft.Pump operating point will be thecrossing point of H-Q curve andSystem curve "R".B.H.P. will be the point on theB.H.P. curve corresponding tothe point on the operatingcurve.B.H.P. shown as oblique lineswill be reduced.

OperationPower Oil pressure Electric actuatorPump size Large size of 2000mm or more Minor size below 2000mm

Operationmechanism

Pressure oil is introduced intoservo cylinder and operating rod isoperated up and down with a servopiston

An operating rod is operated upand down with worm gear andscrew mechanism

Installationposition ofblade controlsystem

Motor top Middle of pump and motor

Features

・Big power can be obtained・An operation mechanism is smalland can make pump height low・It is necessary to make a motorshaft hollow・Oil unit is necessary

・Oil unit is unnecessary・There is no necessity ofmaking a motor shaft hollow・Blade control system becomescomparatively large-size andpump height becomes height

Japanese