+ All Categories
Home > Documents > Models: Installers Guide 6000TRI-IPI 6000TRI-SP• Do not use any phone in your building. •...

Models: Installers Guide 6000TRI-IPI 6000TRI-SP• Do not use any phone in your building. •...

Date post: 11-Aug-2020
Category:
Upload: others
View: 0 times
Download: 0 times
Share this document with a friend
30
Heat & Glo 6000TRI-IPI, 6000TRI-SP 385-901 Rev. F 5/05 1 - Do not store or use gasoline or other flam- mable vapors and liquids in the vicinity of this or any other appliance. - What to do if you smell gas Do not try to light any appliance. Do not touch any electrical switch. Do not use any phone in your building. Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's instructions. If you cannot reach your gas supplier, call the fire department. - Installation and service must be performed by a qualified installer, service agency, or the gas supplier. Installers Guide WARNING: IMPROPER INSTALLA- TION, ADJUSTMENT, ALTERATION, SERVICE OR MAINTENANCE CAN CAUSE INJURY OR PROPERTY DAM- AGE. REFER TO THIS MANUAL. FOR ASSISTANCE OR ADDITIONAL INFOR- MATION CONSULT A QUALIFIED IN- STALLER, SERVICE AGENCY, OR THE GAS SUPPLIER. Underwriters Laboratories Listed READ THIS MANUAL BEFORE INSTALLING OR OPERATING THIS APPLIANCE. THIS INSTALLERS GUIDE MUST BE LEFT WITH APPLIANCE FOR FUTURE REFERENCE. 1. This appliance may be installed in an af- termarket, permanently located, manufac- tured (mobile) home, where not prohibited by local codes. 2. This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases, unless a certified kit is used. Please contact your Heat & Glo dealer with any questions or concerns. For the number of your nearest Heat & Glo dealer, please call 1-888-427-3973. Printed in U.S.A. Copyright 2005, Heat & Glo, a brand of Hearth & Home Technologies Inc. 20802 Kensington Boulevard, Lakeville, MN 55044 WARNING: IF THE INFORMATION IN THESE INSTRUCTIONS IS NOT FOLLOWED EXACTLY, A FIRE OR EXPLOSION MAY RESULT CAUS- ING PROPERTY DAMAGE, PER- SONAL INJURY, OR DEATH. This product is covered by one or more of the following patents: (United States) 4,112,913; 4,408,594; 4,422,426; 4,424,792; 4,520,791; 4,793,322; 4,852,548; 4,875,464; 5,000,162; 5,016,609; 5,076,254 5,191,877; 5,218,953; 5,328,356; 5,429,495; 5,452,708; 5,542,407; 5,613,487; (Australia) 543790; 586383; (Canada) 1,123,296; 1,297,746; 2,195,264; (Mexico) 97-0457; (New Zealand) 200265; or other U.S. and foreign patents pending. Models: 6000TRI-IPI 6000TRI-SP
Transcript
Page 1: Models: Installers Guide 6000TRI-IPI 6000TRI-SP• Do not use any phone in your building. • Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's

Heat & Glo • 6000TRI-IPI, 6000TRI-SP • 385-901 Rev. F • 5/05 1

- Do not store or use gasoline or other flam-mable vapors and liquids in the vicinity of thisor any other appliance.

- What to do if you smell gas• Do not try to light any appliance.• Do not touch any electrical switch.• Do not use any phone in your building.• Immediately call your gas supplier from a

neighbor's phone. Follow the gas supplier'sinstructions.

• If you cannot reach your gas supplier, callthe fire department.

- Installation and service must be performed by aqualified installer, service agency, or the gassupplier.

Installers Guide

WARNING: IMPROPER INSTALLA-TION, ADJUSTMENT, ALTERATION,SERVICE OR MAINTENANCE CANCAUSE INJURY OR PROPERTY DAM-AGE. REFER TO THIS MANUAL. FORASSISTANCE OR ADDITIONAL INFOR-MATION CONSULT A QUALIFIED IN-STALLER, SERVICE AGENCY, OR THEGAS SUPPLIER.

UnderwritersLaboratories Listed

READ THIS MANUAL BEFORE INSTALLING OROPERATING THIS APPLIANCE. THIS INSTALLERSGUIDE MUST BE LEFT WITH APPLIANCE FORFUTURE REFERENCE.

1. This appliance may be installed in an af-termarket, permanently located, manufac-tured (mobile) home, where not prohibitedby local codes.

2. This appliance is only for use with the typeof gas indicated on the rating plate. Thisappliance is not convertible for use withother gases, unless a certified kit is used.

Please contact your Heat & Glo dealer with anyquestions or concerns. For the number of your nearestHeat & Glo dealer, please call 1-888-427-3973.

Printed in U.S.A. Copyright 2005,Heat & Glo, a brand of Hearth & Home Technologies Inc.20802 Kensington Boulevard, Lakeville, MN 55044

WARNING: IF THE INFORMATIONIN THESE INSTRUCTIONS IS NOTFOLLOWED EXACTLY, A FIRE OREXPLOSION MAY RESULT CAUS-ING PROPERTY DAMAGE, PER-SONAL INJURY, OR DEATH.

This product is covered by one or more of the following patents: (United States) 4,112,913; 4,408,594; 4,422,426; 4,424,792; 4,520,791; 4,793,322;4,852,548; 4,875,464; 5,000,162; 5,016,609; 5,076,254 5,191,877; 5,218,953; 5,328,356; 5,429,495; 5,452,708; 5,542,407; 5,613,487; (Australia)543790; 586383; (Canada) 1,123,296; 1,297,746; 2,195,264; (Mexico) 97-0457; (New Zealand) 200265; or other U.S. and foreign patents pending.

Models:6000TRI-IPI6000TRI-SP

laquas
New Stamp
Page 2: Models: Installers Guide 6000TRI-IPI 6000TRI-SP• Do not use any phone in your building. • Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's

Heat & Glo • 6000TRI-IPI, 6000TRI-SP • 385-901 Rev. F • 5/052

These units MUST use one of the vent systemsdescribed in the Installing the Fireplace section ofthe Installers Guide. NO OTHER vent systems orcomponents MAY BE USED.

This gas fireplace and vent assembly MUST bevented directly to the outside and MUST NEVER beattached to a chimney serving a separate solid fuelburning appliance. Each gas appliance MUST USEa separate vent system. Common vent systems arePROHIBITED.

INSPECT the external vent cap on a regular basis tomake sure that no debris is interfering with the airflow.

The glass door assembly MUST be in place andsealed, and the trim door assembly MUST be inplace on the fireplace before the unit can be placedinto safe operation.

DO NOT OPERATE this appliance with the glassdoor removed, cracked, or broken. Replacement ofthe glass door should be performed by a licensedor qualified service person. DO NOT strike or slamthe glass door.

The glass door assembly SHALL ONLY bereplaced as a complete unit, as supplied by the gasfireplace manufacturer. NO SUBSTITUTE materialmay be used.

DO NOT USE abrasive cleaners on the glass doorassembly. DO NOT ATTEMPT to clean the glassdoor when it is hot.

Turn off the gas before servicing this appliance. It isrecommended that a qualified service technicianperform an appliance check-up at the beginning ofeach heating season.

Any safety screen or guard removed for servicingmust be replaced before operating this appliance.

DO NOT place furniture or any other combustiblehousehold objects within 36 inches of the fireplacefront.

READ and UNDERSTAND all instructions carefullybefore starting the installation. FAILURE TOFOLLOW these installation instructions may resultin a possible fire hazard and will void the warranty.

Prior to the first firing of the fireplace, READ theUsing Your Fireplace section of the Owners Guide.

DO NOT USE this appliance if any part has beenunder water. Immediately CALL a qualified servicetechnician to inspect the unit and to replace any partof the control system and any gas control which hasbeen under water.

THIS UNIT IS NOT FOR USE WITH SOLID FUEL.

Installation and repair should be PERFORMED by aqualified service person. The appliance and ventingsystem should be INSPECTED before initial useand at least annually by a professional serviceperson. More frequent cleaning may be requireddue to excessive lint from carpeting, beddingmaterial, etc. It is IMPERATIVE that the unit’scontrol compartment, burners, and circulating airpassageways BE KEPT CLEAN to provide foradequate combustion and ventilation air.

Always KEEP the appliance clear and free fromcombustible materials, gasoline, and otherflammable vapors and liquids.

NEVER OBSTRUCT the flow of combustion andventilation air. Keep the front of the applianceCLEAR of all obstacles and materials for servicingand proper operations.

Due to the high temperature, the appliance shouldbe LOCATED out of traffic areas and away fromfurniture and draperies. Clothing or flammablematerial SHOULD NOT BE PLACED on or near theappliance.

Children and adults should be ALERTED to thehazards of high surface temperature and shouldSTAY AWAY to avoid burns or clothing ignition.Young children should be CAREFULLY SUPERVISEDwhen they are in the same room as the appliance.

!

!

!

!

!!

!

! !

!

!

!

!

!

!

!

!

SAFETY AND WARNING INFORMATION

!

!

Page 3: Models: Installers Guide 6000TRI-IPI 6000TRI-SP• Do not use any phone in your building. • Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's

Heat & Glo • 6000TRI-IPI, 6000TRI-SP • 385-901 Rev. F • 5/05 3

TABLE OF CONTENTS

Safety and Warning Information ................................................ 2

Service Parts Lists ..................................................................... 4

Section 1: Approvals and Codes ............................................... 8Appliance Certification................................................................... 8Installation Codes .......................................................................... 8High Altitude Installations ............................................................... 8

Section 2: Getting Started ......................................................... 9Introducing the Heat & Glo Gas Fireplaces ................................... 9Pre-installation Preparation ........................................................... 9

Section 3: Installing the Fireplace ........................................... 11Constructing the Fireplace Chase ............................................... 11Step 1 Locating the Fireplace .................................................. 11Step 2 Framing the Fireplace.................................................. 12Step 3 Installing the Vent System............................................ 14

A. Vent System Approvals ........................................... 14B. Installing Vent Components .................................... 21C. Vent Termination .................................................... 24

Step 4 Positioning, Leveling, andSecuring the Fireplace................................................. 26

Step 5 Installing the Optional Heat-Zone Kit ............................ 27Step 6 The Gas Control Systems ........................................... 27Step 7 The Gas Supply Line ................................................... 28Step 8 Gas Pressure Requirements ...................................... 28Step 9 Wiring the Fireplace .................................................... 30Step 10 Finishing ...................................................................... 31Step 11 Installing Trim, Logs, and Ember Material .................... 32

Installing the Trim ......................................................... 32Positioning the Logs .................................................... 32Shutter Settings ........................................................... 32Placing the Ember Material .......................................... 32Glass Specifications .................................................... 32

Step 12 Before Lighting the Fireplace ....................................... 33Step 13 Lighting the Fireplace .................................................. 34After the Installation ..................................................................... 34

Section 4: Maintaining and Servicing Your Fireplace ......... 34

= Contains updated information.

Page 4: Models: Installers Guide 6000TRI-IPI 6000TRI-SP• Do not use any phone in your building. • Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's

Heat & Glo • 6000TRI-IPI, 6000TRI-SP • 385-901 Rev. F • 5/058

Appliance CertificationThe Heat & Glo fireplace models discussed in this InstallersGuide have been tested to certification standards and listedby the applicable laboratories.

CertificationMODELS: 6000TRI-IPI, 6000TRI-SPLABORATORY: Underwriters LaboratoriesTYPE: Direct Vent Gas Fireplace HeaterSTANDARD: ANSI Z21.88-2000•CSA2.33-M98•UL307B

Installation CodesThe fireplace installation must conform to local codes. Beforeinstalling the fireplace, consult the local building codeagency to ensure that you are in compliance with allapplicable codes, including permits and inspections.

In the absence of local codes, the fireplace installation mustconform to the National Fuel Gas Code ANSI Z223.1 (inthe United States) or the CAN/CGA-B149 Installation Codes(in Canada). The appliance must be electrically groundedin accordance with local codes or, in the absence of localcodes with the National Electric Code ANSI/NFPA No. 70(in the United States), or to the CSA C22.1 Canadian ElectricCode (in Canada).

These models may be installed in a bedroom or bed-sittingroom in the U.S.A. and Canada.

1Approvals andCodes

High Altitude InstallationsU.L. Listed gas appliances are tested and approved withoutrequiring changes for elevations from 0 to 2,000 feet in theU. S. A. and in Canada.

When installing this appliance at an elevation above 2,000feet, it may be necessary to decrease the input rating bychanging the existing burner orifice to a smaller size. Inputrate should be reduced by 4% for each 1000 feet above a2000 foot elevation in the U.S.A. or 10% for elevationsbetween 2000 and 4500 feet in Canada. If the heating valueof the gas has been reduced, these rules do not apply. Toidentify the proper orifice size, check with the local gasutility.

If installing this appliance at an elevation above 4,500 feet(in Canada), check with local authorities.

Heat & Glo Quality Systemsregistered by SGS ICS

Page 5: Models: Installers Guide 6000TRI-IPI 6000TRI-SP• Do not use any phone in your building. • Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's

Heat & Glo • 6000TRI-IPI, 6000TRI-SP • 385-901 Rev. F • 5/05 9

2Getting Started

Introducing the Heat & Glo Gas FireplacesHeat & Glo direct vent gas fireplaces are designed to oper-ate with all combustion air siphoned from outside of thebuilding and all exhaust gases expelled to the outside.

The information contained in this Installers Guide, unlessnoted otherwise, applies to all models and gas controlsystems. Gas fireplace diagrams, including the dimensions,are shown in this section.

Pre-install PreparationThis gas fireplace and its components are tested and safewhen installed in accordance with this Installers Guide.Report to your dealer any parts damaged in shipment,particularly the condition of the glass. Do not install anyunit with damaged, incomplete, or substitute parts.

The vent system components and trim doors are shippedin separate packages. The gas logs may be packagedseparately and must be field installed.

Read all of the instructions before starting theinstallation. Follow these instructions carefully duringthe installation to ensure maximum safety and benefit.Failure to follow these instructions will void theowner’s warranty and may present a fire hazard.

The Heat & Glo Warranty will be voided by, and Heat & Glodisclaims any responsibility for, the following actions:• Installation of any damaged fireplace or vent system

component.• Modification of the fireplace or direct vent system.• Installation other than as instructed by Heat & Glo.• Improper positioning of the gas logs or the glass door.• Installation and/or use of any component part not manu-

factured and approved by Heat & Glo, not withstandingany independent testing laboratory or other party approvalof such component part or accessory.

ANY SUCH ACTION MAY POSSIBLY CAUSE A FIREHAZARD.

When planning a fireplace installation, it’s necessary todetermine:• Where the unit is to be installed.• The vent system configuration to be used.• Gas supply piping.• Electrical wiring.• Framing and finishing details.• Whether optional accessories—devices such as a fan,

wall switch, or remote control—are desired.If the fireplace is to be installed on carpeting or tile, or onany combustible material other than wood flooring, thefireplace should be installed on a metal or wood panel thatextends the full width and depth of the fireplace.

Page 6: Models: Installers Guide 6000TRI-IPI 6000TRI-SP• Do not use any phone in your building. • Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's

Heat & Glo • 6000TRI-IPI, 6000TRI-SP • 385-901 Rev. F • 5/0510

Figure 1. Diagram of the 6000TRI-IPI, 6000TRI-SP

TOP VENT COLLARS

REAR VENT COLLARS

GASLINE

ACCESS ELECTRICALACCESS

GASCONTROLS

RATING PLATEAND LABELS

TRIMDOOR

HOOD

TOP STANDOFFS

41 1/8[1044mm]

38[965mm]

36 1/8[916mm]

25 1/4[642mm]

34 5/8[879mm]

VENTCOLLARS

ELECTRICALACCESS

26 7/8[682mm]

12 3/4[323mm]

3 1/2[90mm]

GAS LINEACCESS

2 1/8[55mm]

6 7/8 [174mm]

14 1/4 [362mm]

8 [203mm]VENT COLLARS

21 1/2 [548mm]

11 5/8 [297mm]

28 1/2 [724mm]

8 [203mm]

Page 7: Models: Installers Guide 6000TRI-IPI 6000TRI-SP• Do not use any phone in your building. • Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's

Heat & Glo • 6000TRI-IPI, 6000TRI-SP • 385-901 Rev. F • 5/05 11

3 Installing the Fireplace

Step 1. Locating the FireplaceThe following diagram shows space and clearance require-ments for locating a fireplace within a room.

Minimum Clearances from the Fireplace to Combustible Materials

Inches mmGlass Front ........................ 36 .................... 914Floor ................................... 0 ....................... 0Rear ...................................1/2 ..................... 13Sides .................................1/2 ..................... 13Surround Sides* .................. 0 ....................... 0Top ................................... 3 1/2 ................... 89Ceiling** ............................. 31 .................... 787

Figure 2. Fireplace Dimensions, Locations, and Space Requirements

Minimum Clearances from the Vent Pipe to Combustible Materials

Inches mmVertical Sections. ............. 1 ................ 25

Horizontal SectionsTop ..................................... 3 ................ 75Bottom ............................... 1 ................ 25Sides ................................. 1 ................ 25

At Wall FirestopsTop ..................................... 3 ................ 75Bottom ............................... 1 ................ 25Sides ................................. 1 ................ 25

* See Figure 3.** The clearance to the ceiling is measured from the top

of the unit, excluding the standoffs (see Figure 39).

The distance from the unit to combustible constructionis to be measured from the unit outer wrap surface tothe combustible construction, NOT from the screw headsthat secure the unit together.

For minimum clearances, see the direct vent terminationclearance diagrams on pages 24 and 25 in this manual.

1/2” MIN. (13mm)

D

C

E

B

1” MIN. (25mm)

A

Clearance RequirementsThe top, back, and sides of the fireplace are defined bystand-offs. The minimum clearance to a perpendicular wallextending past the face of the fireplace is one inch (25 mm).The back of the fireplace may be recessed 21 1/2 inches(546 mm) into combustible construction.

Constructing the Fireplace Chase

A chase is a vertical box-like structure built to enclose thegas fireplace and/or its vent system. Vertical vents that runon the outside of a building may be, but are not required tobe, installed inside a chase.

CAUTION: TREATMENT OF FIRESTOP SPACERS ANDCONSTRUCTION OF THE CHASE MAY VARY WITH THETYPE OF BUILDING. THESE INSTRUCTIONS ARE NOTSUBSTITUTES FOR THE REQUIREMENTS OF LOCALBUILDING CODES. THEREFORE, YOUR LOCAL BUILD-ING CODES MUST BE CHECKED TO DETERMINE THEREQUIREMENTS FOR THESE STEPS.

Factory-built fireplace chases should be constructed in themanner of all outside walls of the home to prevent cold airdrafting problems. The chase should not break the outsidebuilding envelope in any manner.

This means that the walls, ceiling, base plate and cantile-ver floor of the chase should be insulated. Vapor and airinfiltration barriers should be installed in the chase as perregional codes for the rest of the home. Additionally, Heat &Glo recommends that the inside surfaces be sheetrockedand taped for maximum air tightness.

To further prevent drafts, the firestops should be caulked toseal gaps. Gas line holes and other openings should becaulked or stuffed with insulation. If the unit is being in-stalled on a cement slab, we recommend that a layer ofplywood be placed underneath to prevent conducting coldup into the room. Be sure to include spark arrestors forwoodburning units if they are required.

THE CHASE SHOULD BE CONSTRUCTED SO THAT ALLCLEARANCES TO THE FIREPLACE ARE MAINTAINEDAS SPECIFIED WITHIN THIS INSTALLERS GUIDE.

A B C D E42” 22” 36” 51” 72”

Note* 42” 22” 40” 57” 80”*If venting with (2) 900 elbows off rear of unit the dimensions C, D, and E, will change.

Page 8: Models: Installers Guide 6000TRI-IPI 6000TRI-SP• Do not use any phone in your building. • Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's

Heat & Glo • 6000TRI-IPI, 6000TRI-SP • 385-901 Rev. F • 5/0512

Framing should beconstructed of 2 X 4lumber or heavier.

A. ............. 42”*

B. ......... 38 1/2”

C. ............... 22”

D. ......... 42 3/4”

E. ......... 27 7/8”

Figure 3. Framing Dimensions

Step 2. Framing the Fireplace

Fireplace framing can be built before or after the fireplace isset in place. Framing should be positioned to accommo-date wall coverings and fireplace facing material. The dia-gram below shows framing reference dimensions.

CAUTION: MEASURE FIREPLACE DIMENSIONS ANDVERIFY FRAMING METHODS AND WALL COVERINGDETAILS BEFORE FRAMING.

1/2” CLEARANCE FROM BACK OF FIREPLACE TO COMBUSTIBLE

0” CLEARANCE TOFRAMING MEMBER0” CLEARANCE

1/2” CLEARANCEFROM BOTH SIDES

OF FIREPLACETO COMBUSTIBLE

FRAMINGMEMBER

Shows center of 10” x 12” vent framingholes for top and rear venting. The centerof the hole is one (1) inch (25.4mm) abovethe center of the horizontal vent pipe.

E D

A

B

C

WALLSTUD

3 1/2”

3”

Noncombustible zone is definedby 3” above the elbow for theentire width and depth (behindthe front header) of the firebox.

Page 9: Models: Installers Guide 6000TRI-IPI 6000TRI-SP• Do not use any phone in your building. • Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's

Heat & Glo • 6000TRI-IPI, 6000TRI-SP • 385-901 Rev. F • 5/05 13

Figure 4. DVP-Series Direct Vent Component Specifications (5-inch inner pipe / 8-inch outer pipe)

NOTE: PIPES OVERLAP 1-1/4 INCHES AT EACH JOINT.

DVP90ST

12-9/16

11-1/4

7-1/4

1-1/4 TYP

1/2 TYP8-9/16

DVP36

DVP48

48

24

36

46

DVP4

DVP6

12

DVP12

2MIN.

DVP12A

12-3/16MAX.

DVP249-7/8

45.0O

10-1/4

DVP45

14-1/4

Page 10: Models: Installers Guide 6000TRI-IPI 6000TRI-SP• Do not use any phone in your building. • Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's

Heat & Glo • 6000TRI-IPI, 6000TRI-SP • 385-901 Rev. F • 5/0514

Figure 5. Vent System Components and Termination Kits

Step 3. Installing the Vent SystemA. Vent System Approvals

These models are approved to use DVP-series direct ventpipe components and terminations (see Figures 4 and 5).Approved vent system components are labeled for identifi-cation. This pipe is tested and listed as an approved com-ponent of the fireplace. The pipe is tested to be run insidean enclosed wall. There is no requirement for inspectionopenings at each joint within the wall. There is no requiredpitch for horizontal vent runs. NO OTHER VENTING SYS-TEMS OR COMPONENTS MAY BE USED.

Detailed installation instructions are included with each venttermination kit and should be used in conjunction with thisInstallers Guide.

The flame and ember appearance may vary based on the typeof fuel burned and the venting configuration used.

Identifying Vent Components

The vent systems installed on this gas fireplace may in-clude one, two, or three 90° elbow assemblies. The rela-tionships of vertical rise to horizontal run in vent configura-tions using 90° elbows MUST BE strictly adhered to. Therise to run relationships are shown in the venting drawingsand tables. Refer to the diagrams on the next several pages.

NOTE: Two 45° elbows may be used in place of one90° elbow. Rise to run ratios in the vent system mustbe followed if 45° elbows are used.

This model has vent starting collars on both the top and theback of the unit. Depending upon the installation, decidewhich ONE set of starting collars will be used to attach thevent system. The starting collar sealing cap must remainon the starting collar NOT used.

HORIZONTALTERMINATION

WALL FIRESTOP

90 DEGREEELBOW

PIPE LENGTH

CEILINGFIRESTOP

VERTICALTERMINATION

STORM COLLAR

ROOF FLASHING

Terminations Kits

(For use on IPI units only)DVP-TVPVK-80

DVP-TVHWDVP-TRAP DVP-TB1(Required to have a minimum of 3feet of vertical in the vent system)

SERIES

Page 11: Models: Installers Guide 6000TRI-IPI 6000TRI-SP• Do not use any phone in your building. • Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's

Heat & Glo • 6000TRI-IPI, 6000TRI-SP • 385-901 Rev. F • 5/05 15

Figure 6.Straight Up Vertical Venting

STRAIGHT UPVERTICAL VENTING

V (FT.)

40' MAX. (12.4 M)

Flue Restrictor Instructions

1. Remove Exhaust Shield using a 1/4” nut driver byremoving the four screws securing it in place (seeFigure 7).

Figure 8. Flue Restrictor

BREAKHERE

Figure 7

EXHAUSTSHIELD

FLUERESTRICTOR

2. Break the Flue Restrictor into two pieces. Do thisby bending the part back and forth until it breaks(see Figure 8).

NOTE: On vertical ventingconfigurations over 10 feetinstall the flue restrictor(385-128) included in themanual bag assembly. Seeflue restrictor instructions.

Page 12: Models: Installers Guide 6000TRI-IPI 6000TRI-SP• Do not use any phone in your building. • Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's

Heat & Glo • 6000TRI-IPI, 6000TRI-SP • 385-901 Rev. F • 5/0516

HORIZONTAL VENTINGKit No. H Max. RunDVP-TRAP 24" (610 mm)

Figure 11. Corner Installation

NOTE: This model is tested and approved to use45° elbows in corner installations. However, 90°elbows will result in better performance. Theuse of two 900 elbows in a corner installationwill affect space requirements (see Figure 2).

45-DEGREEELBOW

90-DEGREEELBOWS

H

3. Match the amount of vertical you have in the sys-tem with the chart to find the appropriate positionto set the Flue Restrictor (see Figure 9).

1 2 3 4 5

SETTINGS

1 2 3 4 5

Figure 10

- CHART -Vertical Top Vent

NGTop Vent

LPRear Vent

NGRear Vent

LP

4' 1-1 NoRestrictor

NoRestrictor

NoRestrictor

8' 2-2 1-2 1-1 NoRestrictor

15' 3-3 3-2 2-2 1-2

20' 3-4 3-3 3-3 2-3

25' 3-4 3-3 3-3 2-3

30' 4-4 3-4 3-4 3-3

35' 4-4 3-4 3-4 3-3

40' 5-4 4-4 4-4 3-4

4. Center the Flue Restrictor on vent and secure inplace by using two self-tapping screws.

5. Reinstall the Exhaust Shield.

Figure 9

Page 13: Models: Installers Guide 6000TRI-IPI 6000TRI-SP• Do not use any phone in your building. • Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's

Heat & Glo • 6000TRI-IPI, 6000TRI-SP • 385-901 Rev. F • 5/05 17

V H 1' MIN. (305mm) 2' MAX. (610mm) 2' MIN. (610mm) 4' MAX. (1.22m) 3' MIN. (914mm) 6' MAX. (1.86m) 4' MIN. (1.22m) 8' MAX. (2.4m)

V+H=40' MAX. (12.4m) H = 8' MAX. (2.4m)

NOTE: On vertical venting configurations wherethe vertical component is over 10 feet, installthe flue restrictor included in the manual bagassembly to improve flame appearance.

Figure 12. Venting with One 90° Elbow

VENTING WITH ONE (1) 90° ELBOW

VENTING WITH ONE (1) 90° ELBOW

V (FT.) H (FT.) 1' MIN. (305mm) 5' MAX. (1.52m) 2' MIN. (610mm) 10' MAX. (3.1m) 3' MIN. (914mm) 15' MAX. (4.65m) 4' MIN. (1.22m) 20' MAX. (6.2m)

V+H= 40’ MAX. (12.4MM) H = 20' MAX. (6.2m)

Figure 13. Venting with One 90° Elbow

NOTE: If a 90o elbow is first attached to the unit,the maximum horizontal run is 3-feet (914mm).

NOTE: For corner installations: A 6-inch (152mm)section of straight pipe may need to be attached tothe fireplace before a 90o elbow, to allow the ventpipe to clear the top standoffs.

H

V

V

H

H

V

Page 14: Models: Installers Guide 6000TRI-IPI 6000TRI-SP• Do not use any phone in your building. • Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's

Heat & Glo • 6000TRI-IPI, 6000TRI-SP • 385-901 Rev. F • 5/0518

Figure 14. Venting with Two 90° Elbows

VENTING WITH TWO (2)90° ELBOWS

V H H + H1

1´ MIN. (305 mm) 2´ MAX. (610 mm) 5´ MAX. (1.52m)2´ MIN. (610 mm) 4´ MAX. (1.22 m) 10´ MAX. (3.1m)3´ MIN. (914 mm) 6´ MAX. (1.86 m) 15´ MAX. (4.65m)4´ MIN. (1.22 m) 8´ MAX. (2.48 m) 20´ MAX. (6.2m)

V+H+H1= 40´ MAX. (12.4 m) H = 8´ MAX. (2.48 m) H+H1= 20´ MAX. (6.2m)

Figure 15. Venting with Two 90° Elbows

VENTING WITH TWO (2) 90o ELBOWS

V FT. H + H1 (FT.)1' MIN. (305mm) 5´ MAX. (1.52m)2' MIN. (610mm) 10´ MAX. (3.1m)3' MIN. (914mm) 15´ MAX. (4.65m)4' MIN. (1.22m) 20´ MAX. (6.2m)

V+H+H1= 40' MAX.(12.4m) H+H1 = 20´ MAX. (6.2m)V+V1+H= 40' MAX.(12.4m)

H1

V

H

H1

H

V

V

V1

H

Page 15: Models: Installers Guide 6000TRI-IPI 6000TRI-SP• Do not use any phone in your building. • Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's

Heat & Glo • 6000TRI-IPI, 6000TRI-SP • 385-901 Rev. F • 5/05 19

Figure 16. Venting with three 90° elbows

VENTING WITH THREE (3) 90° ELBOWS

1´MIN. (305mm) 2´MAX. (610mm) 5´MAX. (1.52m)2´MIN. (610mm) 4´MAX. (1.22m) 10´MAX. (3.1m)3´MIN. (914mm) 6´MAX. (1.86m) 15´MAX. (4.65m)4´MIN. (1.22m) 8´MAX. (2.48m) 20´MAX. (6.2m)

V+H+H1+H2 = 40´ MAX. (12.4 m) H = 8´ MAX. (2.48 m) H+H1+H2 = 20´ MAX. (6.2 m)

V H H + H1 + H2

1´MIN. (305mm) 2´MAX. (610mm) 5´MAX. (1.52m)2´MIN. (610mm) 4´MAX. (1.22m) 10´MAX. (3.1m)3´MIN. (914mm) 6´MAX. (1.86m) 15´MAX. (4.65m)4´MIN. (1.22m) 8´MAX. (2.48m) 20´MAX. (6.2m)

V1+V+H+H1 = 40´ MAX.(12.4 m) H = 8´MAX.(2.48 m) H+H1 = 20´MAX.(6.2 m)

V H H + H1

H

H1

H2

V

H

V

H1

V1

Page 16: Models: Installers Guide 6000TRI-IPI 6000TRI-SP• Do not use any phone in your building. • Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's

Heat & Glo • 6000TRI-IPI, 6000TRI-SP • 385-901 Rev. F • 5/0520

VENTING WITH THREE (3) 90° ELBOWS

V (FT.) H (FT.)1' MIN. (305mm) 5' MAX. (1.52m)2' MIN. (610mm) 10' MAX. (3.1m)3' MIN. (914mm) 15' MAX. (4.65m)4' MIN. (1.22m) 20' MAX. (6.2m)

NOTE: H + H1 = 20' MAX. (6.2m)V + V1 + H + H1= 40' MAX. (12.4m)

V + V1 (FT.) H + H1 (FT.)1' MIN. (305mm) 5' MAX. (1.52m)2' MIN. (610mm) 10' MAX. (3.1m)3' MIN. (914mm) 15' MAX. (4.65m)4' MIN. (1.22m) 20' MAX. (6.2m)

H +H1 = 20' MAX. (6.2m)NOTE: V+V1+H +H1= 40' MAX. (12.4m)

Figure 17. Venting with three 90° elbows

V

H

H1

V1

VH

H1

V1

Page 17: Models: Installers Guide 6000TRI-IPI 6000TRI-SP• Do not use any phone in your building. • Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's

Heat & Glo • 6000TRI-IPI, 6000TRI-SP • 385-901 Rev. F • 5/05 21

!

B. Installing Vent ComponentsAfter determining which set of starting collars will be used(top or rear), follow venting instructions accordingly.Venting Out the Rear VentRemove the installed rear seal cap from the rear startingcollars by cutting the strap at each end. (see Figure 18).Follow the vent configuration tables accordingly.

Remove the insulation from the REAR five inch flue, pullthe heat shield out from outside of the firebox.

WARNING: THE TOP HEAT SHIELD (INSIDETHE FIREBOX) MUST REMAIN ATTACHED IFTHE VENT SYSTEM IS ATTACHED TO THEREAR STARTING COLLARS. SEE FIGURE 18.

Venting Out the Top VentRemove the two screws in the top vent collar seal cap andremove the top vent collar seal cap and two pieces of in-sulation inside the top two starting collars (See Figure 18).

Remove the heat shield from inside the TOP five inch fluefrom outside of the firebox.

The glass must be taken off again for positioning the logswhen the unit is finally installed in place and finished aroundit. Re-install the glass door. Attach vent system to the topstarting collars.

Figure 18

Cut the seal capstrap and remove white

gasket material.

CUTHERE

Venting Out Rear Venting Out Top

HEATSHIELD

DISCARD INSULATION

andHEAT SHIELD

HEAT SHIELD

INSULATIONDISCARD BOTH

PIECES andHEAT SHIELD

SEAL CAP

SEALCAP

1. Attach the First Vent Component to the Starting CollarsTo attach the first vent component to the starting collars ofthe fireplace:• Make sure that the fiberglass gasket supplied in the

manual bag seals between the first 8 inch (203mm)vent component and the outer fireplace wrap. Using 2self-tapping screws from the manual bag secure thatgasket to the outer wrap (see Figure 19).

Figure 19. Fiberglass Gasket

FIRST VENTCOMPONENT

FIBERGLASSGASKET

OUTERWRAP

DVP PIPE:

2. Assembling Vent SectionsRefer to Cinch Pipe and Termination Cap installation in-structions.

1. Attaching the Venting to the FireplaceRefer to Cinch Pipe and Termination Cap installation in-structions.

! WARNING: THE REAR VENT COLLAR SEALCAP MUST REMAIN ATTACHED TO THE REAR

VENT COLLARS IF THE VENT SYSTEM IS ATTACHEDTO THE TOP STARTING COLLARS.

!WARNING: FAILURE TO REMOVE INSULATIONIN THE SET OF COLLARS YOU ARE USINGCOULD NEGATIVELY AFFECT FIREPLACEPERFORMANCE.

! WARNING: YOU MUST LEAVE THE INSULA-TION IN PLACE IN THE SET OF COLLARS YOUARE NOT USING. FAILURE TO DO THIS COULDCAUSE A FIRE.

Page 18: Models: Installers Guide 6000TRI-IPI 6000TRI-SP• Do not use any phone in your building. • Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's

Heat & Glo • 6000TRI-IPI, 6000TRI-SP • 385-901 Rev. F • 5/0522

3. Continue Adding Vent Components

WARNING: INSTALLATION OF THIS FIRE-PLACE REQUIRES THE USE OF HEAT

SHIELD 570-290 ABOVE THE FIRST 900 ELBOW INTHE VENTING SYSTEM.

Figure 20

To Install the Heat Shield:1. Determine if the heat shield is required. Do so by mea-

suring the vertical distance between the top horizontalsurface of the elbow to any combustible surface above.If the distance is more than 4 inches, the heat shield isNOT required. If it is 4 inches or less, the heat shield ISREQUIRED. Install per the following steps. See Figure 20.

!

Figure 21

CORRECT INCORRECT

2. Fasten the shield in place using the four pilot holes pro-vided in the part. The shield should be oriented such thatthe 13 1/8 inch dimension (longest dimension) is run-ning in the same direction the elbow is pointing. Theshield should be centered directly above the elbow, andpositioned so that it creates a 1/2 inch airspace betweenthe shield and the combustible surface. See Figure 21.

HEATSHIELD

3” MIN.(76mm)

COMBUSTIBLESURFACE

COMBUSTIBLE SURFACE

DIRECTIONUP

HEAT SHIELD

90 ELBOW0

Figure 22

• If the combustible materials are not in place at the timeof install the elbow heat shield may be screwed to theexhaust pipe (see Figure 22). Cut the tabs as shownand bend down. Secure the heat shield to the pipe main-taining 3” to 4” between the pipe and shield.

3”(76mm)

SCREW

! WARNING: ENSURE THAT THE FIBERGLASSGASKET SUPPLIED WITH THE FIREPLACE

SEALS BETWEEN THE FIRST VENT COMPONENTAND THE OUTER FIREPLACE WRAP.

If the installation is for a termination cap attached directlyto the fireplace, skip to the sections, Install Firestops andVent Termination.

4. Install Support BracketsRefer to Cinch Pipe and Termination Cap installation in-structions.

• Refer to Cinch Pipe and Termination Cap installation in-structions.

• Continue adding vent components, locking each succeed-ing component into place.

• Ensure that each succeeding vent component is secure-ly fitted and locked into the preceding component in thevent system.

• 90° elbows may be installed and rotated to any pointaround the preceding component’s vertical axis. If an el-bow does not end up in a locked position with the pre-ceding component, attach with a minimum of two (2)sheet metal screws.

Page 19: Models: Installers Guide 6000TRI-IPI 6000TRI-SP• Do not use any phone in your building. • Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's

Heat & Glo • 6000TRI-IPI, 6000TRI-SP • 385-901 Rev. F • 5/05 23

5. Install FirestopsFor Horizontal Runs - Firestops are REQUIRED on bothsides of a combustible wall through which the vent passes.NOTE: Model DVP-TRAP does not need an exteriorfirestop on an exterior combustible wall.To install firestops for horizontal runs that pass througheither interior or exterior walls:• Cut a 10-inch by 12-inch (254mm x 305mm) hole through

the wall.NOTE: The center of the hole is one (1) inch (25.4mm)above the center of the horizontal vent pipe.

• Position the firestops on both sides of the hole previ-ously cut and secure the firestops with nails or screws.

• The heat shields of the firestops MUST BE placed to-wards the top of the hole.

• Continue the vent run through the firestops.

Figure 23. 10" x 12" Hole and Vent Pipe

Figure 24. Heat Shield, Interior & Exterior Firestops

TRIM HEATSHIELD IF TOOLONG, ADD TO SHIELD IF TOOSHORT

EXTERIORFIRESTOP

INTERIORFIRESTOP

HEAT SHIELD

NOTE: There must be NO INSULATION or othercombustibles inside the framed firestop opening.

10"

12"

INTERIORWALL SHIELD

For Vertical Runs - One ceiling firestop is REQUIRED atthe hole in each ceiling through which the vent passes.To install firestops for vertical runs that pass through ceilings:• Position a plumb bob directly over the center of the verti-

cal vent component.

• Mark the ceiling to establish the centerpoint of the vent.

• Drill a hole or drive a nail through this centerpoint.

• Check the floor above for any obstructions, such as wir-ing or plumbing runs.

• Reposition the fireplace and vent system, if necessary,to accommodate the ceiling joists and/or obstructions.

• Cut an 10-inch X 10-inch (254mm X 254mm) hole throughthe ceiling, using the centerpoint previously marked.

• Frame the hole with framing lumber the same size as theceiling joists.

Figure 25. 10" x 10" Hole & New Framing Members

CEILING

NEWFRAMINGMEMBERS

EXISTING CEILING JOISTS

CHIMNEYHOLE

10" (254mm) 10" (254mm)

Page 20: Models: Installers Guide 6000TRI-IPI 6000TRI-SP• Do not use any phone in your building. • Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's

Heat & Glo • 6000TRI-IPI, 6000TRI-SP • 385-901 Rev. F • 5/0524

Figure 28. Trapezoid Termination Cap

7 1/4”(184mm)

Figure 26. Ceiling Firestop (Ceiling Side)

If the area above the ceiling is NOT an attic, position andsecure the ceiling firestop on the ceiling side of the previouslycut and framed hole.

If the area above the ceiling IS an attic, position and securethe firestop on top of the previously framed hole.

NOTE: Keep insulation away from the vent pipe at least1 inch (25mm).

Figure 27. Attic Firestop

JOIST

CEILING FIRESTOP

CEILING

NAILS (4 REQUIRED)

CEILING

CEILING FIRESTOP

RAFTER

NAILS (4 REQUIRED)

NOTE: There must be NO INSULATION or othercombustibles inside the framed firestop opening. !

C. Vent TerminationRefer to Cinch Pipe and Termination Cap installation in-structions.

WARNING: THE TERMINATION CAP MUST BEPOSITIONED SO THAT THE ARROW IS POINT-ING UP.

! WARNING: VENTING TERMINALS SHALLNOT BE RECESSED INTO A WALL OR SID-

ING. VENT TERMINATION CLEARANCES MUSTBE FOLLOWED TO AVOID FIRE DANGER. SEEVENT TERMINATION MINIMUM CLEARANCES DI-AGRAM ON FOLLOWING PAGE.

Page 21: Models: Installers Guide 6000TRI-IPI 6000TRI-SP• Do not use any phone in your building. • Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's

Heat & Glo • 6000TRI-IPI, 6000TRI-SP • 385-901 Rev. F • 5/05 25

V = VENT TERMINAL X = AIR SUPPLY INLET = AREA WHERE TERMINAL IS NOT PERMITTED

Figure 29. Vent Termination Minimum Clearances

A = 12" ....................... clearances above grade, veran-da, porch, deck or balcony

B = 12" ....................... clearances to window or doorthat may be opened, or to per-manently closed window.

D* = 18" ....................... vertical clearance to unventilat-ed soffit or to ventilated soffit lo-cated above the terminal

*30” ...................... for vinyl clad soffits and belowelectrical service

F = 9" ........................ clearance to outside cornerG = 6" ......................... clearance to inside cornerH = 3 ft. (Canada) ...... not to be installed above a gas

meter/regulator assembly within3 feet (90cm) horizontally from thecenter-line of the regulator

I = 3 ft. (U.S.A.)6 ft. (Canada) ...... clearance to gas service regu-

lator vent outletJ = 9" (U.S.A.)

12" (Canada) ........ clearance to non-mechanical airsupply inlet to building or thecombustion air inlet to any otherappliance

K = 3 ft. (U.S.A.)6 ft. (Canada) ......... clearance to a mechanical

air supply inletL** = 7 ft. ......................... clearance above paved

sidewalk or a paved drivewaylocated on public property

M*** = 18" ......................... clearance under veranda,porch, deck, balcony or over-hang

42” ......................... vinylN = 6” ........................... non-vinyl sidewalls

12” ......................... vinyl sidewallsP = 8 ft.

CAUTION: IF EXTERIOR WALLS ARE FINISHED WITH VINYL SIDING, IT IS SUGGESTED THAT A VINYL PROTECTOR KIT BEINSTALLED.

** a vent shall not terminate directly above a sidewalk or paveddriveway which is located between two single family dwellingsand serves both dwellings.

*** only permitted if veranda, porch, deck or balcony is fully open ona minimum of 2 sides beneath the floor, or meets Note 2.

NOTE 1: On private property where termination is less than 7 feetabove a sidewalk, driveway, deck, porch, veranda or balcony, use ofa listed cap shield is suggested.

NOTE 2: Termination in an alcove space (spaces open only on one sideand with an overhang) are permitted with the dimensions specified forvinyl or non-vinyl siding and soffits. 1. There must be 3 feet minimumbetween termination caps. 2. All mechanical air intakes within 10 feetof a termination cap must be a minimum of 3 feet below the terminationcap. 3. All gravity air intakes within 3 feet of a termination cap must bea minimum of 1 foot below the termination cap.

(See Note 1)

(See Note 1)

(See Note 2)

S = 6" .......................... clearance from sides of elec-trical service

T = 12" ......................... clearance above electricalservice

______________________________________________________________________

______________________________________________________________________

______________________________________________________________________

______________________________________________________________________

QMIN RMAX

1 cap 3 feet 2 x Q ACTUAL

2 caps 6 feet 1 x Q ACTUAL

3 caps 9 feet 2/3 x Q ACTUAL

4 caps 12 feet 1/2 x Q ACTUAL

QMIN = # termination caps x 3 RMAX = (2 / # termination caps) x QACTUAL

(See Note 5)

(See Note 5)

ElectricalService

V

SV S

V

T

D*

V

NOTE 3: Local codes or regulations may require differentclearances.

NOTE 4: Termination caps may be hot. Consider their proximity todoors or other traffic areas.

NOTE 5: Location of the vent termination must not interfere withaccess to the electrical service.

WARNING: In the U.S: Vent system termination is NOT permittedin screened porches. You must follow side wall, overhang andground clearances as stated in the instructions.

In Canada: Vent system termination is NOT permitted in screenedporches. Vent system termination is permitted in porch areaswith two or more sides open. You must follow all side walls,overhang and ground clearances as stated in the instructions.

Heat & Glo assumes no responsibility for the improper perfor-mance of the fireplace when the venting system does not meetthese requirements.

DE

BL

v

v v

v

v

v

v

v

BB

A H

MX

J or K

I

A

G

F

U.S.(3 FT)B

MN

PR

Q

Page 22: Models: Installers Guide 6000TRI-IPI 6000TRI-SP• Do not use any phone in your building. • Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's

Heat & Glo • 6000TRI-IPI, 6000TRI-SP • 385-901 Rev. F • 5/0526

For Vertical Terminations - To locate the vent and installthe vent sections:• Locate and mark the vent centerpoint on the underside

of the roof, and drive a nail through the centerpoint.• Make the outline of the roof hole around the centerpoint

nail.• The size of the roof hole framing dimensions depend on the

pitch of the roof. There MUST BE a 1-inch (25.4mm) clear-ance from the vertical vent pipe to combustible materials.

• Mark the roof hole accordingly.• Cover the opening of the installed vent pipes.• Cut and frame the roof hole.• Use framing lumber the same size as the roof rafters

and install the frame securely. Flashing anchored to theframe must withstand heavy winds.

• Continue to install concentric vent sections up throughthe roof hole (for inside vent installations) or up past theroof line until you reach the appropriate distance abovethe roof (for outside terminations).

!

Roof Pitch H (min.) ft.

flat to 6/12 1.06/12 to 7/12 1.25over 7/12 to 8/12 1.5over 8/12 to 9/12 2.0over 9/12 to 10/12 2.5over 10/12 to 11/12 3.25over 11/12 to 12/12 4.0over 12/12 to 14/12 5.0over 14/12 to 16/12 6.0over 16/12 to 18/12 7.0over 18/12 to 20/12 7.5over 20/12 to 21/12 8.0

Figure 30. Minimum Height from Roof to Lowest Discharge Opening

To seal the roof hole, and to divert rain and snow from thevent system:

• Attach a flashing to the roof using nails, and use a non-hardening mastic around the edges of the flashing basewhere it meets the roof.

• Attach a storm collar over the flashing joint to form awater-tight seal. Place non-hardening mastic around thejoint, between the storm collar and the vertical pipe.

• Slide the termination cap over the end of the vent pipeand snap into place.

HORIZONTALOVERHANG

VERTICALWALL

TERMINATIONCAP

12X

ROOF PITCHIS X/ 12

LOWEST DISCHARGE

OPENING

H (MIN.) - MINIMUM HEIGHT FROM ROOFTO LOWEST DISCHARGE OPENING

2 FT.MIN.

20 INCH MIN.

WARNING: MAJOR U.S. BUILDING CODESSPECIFY MINIMUM CHIMNEY AND/OR

VENT HEIGHT ABOVE THE ROOF TOP. THESE MIN-IMUM HEIGHTS ARE NECESSARY IN THE INTER-EST OF SAFETY. SEE THE FOLLOWING DIAGRAMFOR MINIMUM HEIGHTS, PROVIDED THE TERMI-NATION CAP IS AT LEAST 20 INCHES FROM AVERTICAL WALL AND 2-FEET BELOW A HORIZON-TAL OVERHANG.

NOTE: This also pertains to vertical vent systems in-stalled on the outside of the building.

Step 4. Positioning, Leveling, and Securing the Fireplace

• Place the fireplace into position.• Level the fireplace from side to side and front to back.• Shim the fireplace with non-combustible material, such

as sheet metal, as necessary.• Secure the fireplace to the framing by nailing or screwing.

The diagram below shows how to properly position, level,and secure the fireplace.

Figure 31. Proper Positioning,Leveling and Securing of a Fireplace

NAILING TABS(BOTH SIDES)

Page 23: Models: Installers Guide 6000TRI-IPI 6000TRI-SP• Do not use any phone in your building. • Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's

Heat & Glo • 6000TRI-IPI, 6000TRI-SP • 385-901 Rev. F • 5/05 27

!

!

Step 6. The Gas Control Systems

WARNING: THIS UNIT IS NOT FOR USE WITHSOLID FUEL.

The types of gas control systems used with this model areIntermittent Pilot Ignition (IPI) and Standing Pilot Ignition (SP).

WARNING: CONTINUOUS 110-120 VAC SER-VICE MUST BE WIRED DIRECTLY TO THE FIRE-PLACE JUNCTION BOX.

Figure 33. Gas Control System (IPI)

FLAME SENSORROD

Step 5. Installing the Optional Heat-Zone Kit

NOTE: There must be NO INSULATION or other com-bustibles inside the framed firestop opening.

HEAT-ZONEATTACHES

HERE

Figure 32.

1. Remove the knockout from the fireplace and discard it(see Figure 32).

2. Center the duct collar around the exposed hole and at-tach it to the fireplace with 3 screws. NOTE: Do this BE-FORE final positioning of the fireplace.

3. Determine the location for the air register/fan housingassembly.

Reference the Heat-Zone kit instructions for the remaininginstallation steps.

!

Figure 34. Gas Control System (Standing Pilot)

Standing Pilot Ignition SystemThis system includes millivolt control valve, standing pilot,thermopile/thermocouple flame sensor, and piezo ignitor.

WARNING: 110-120 VAC MUST NEVER BECONNECTED TO A CONTROL VALVE IN AMILLIVOLT SYSTEM.

Intermittent Pilot Ignition (IPI) SystemThis system includes a 3V control valve, electronic moduleand intermittent pilot.

Page 24: Models: Installers Guide 6000TRI-IPI 6000TRI-SP• Do not use any phone in your building. • Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's

Heat & Glo • 6000TRI-IPI, 6000TRI-SP • 385-901 Rev. F • 5/0528

Figure 35. Gas Supply Line

• At the gas line access hole, use insulation to re-packthe space around the gas pipe.

• Insert insulation from the outside of the fireplace andpack the insulation tightly to totally seal between thepipe and the outer casing.

Step 7. The Gas Supply LineNOTE: Have the gas supply line installed in accordancewith local building codes by a qualified installer ap-proved and/or licensed as required by the locality. (Inthe Commonwealth of Massachusetts installation mustbe performed by a licensed plumber or gas fitter).NOTE: Before the first firing of the fireplace, the gassupply line should be purged of any trapped air.NOTE: Consult local building codes to properly sizethe gas supply line leading to the 1/2 inch (13mm)hook-up at the unit.This gas fireplace is designed to accept a 1/2 inch(13 mm) gas supply line. To install the gas supply line:• A listed (and Commonwealth of Massachusetts approved)

1/2 inch (13mm) tee-handle manual shut-off valve and alisted flexible gas connector are connected to the 1/2inch (13mm) inlet of the control valve. NOTE: If substi-tuting for these components, please consult local codesfor compliance.

• Locate the gas line access hole in the outer casing ofthe fireplace.

• The gas line may be run from either side of the fireplaceprovided the hole in the outer wrap does not exceed 2 1/2”in diameter and it does not penetrate the actual firebox.

• The gap between the supply piping and gas access holecan be plugged with non-combustible insulation to pre-vent cold air infiltration.

• Open the fireplace lower grille, insert the gas supply linethrough the gas line hole, and connect it to the shut-off valve.

• When attaching the pipe, support the control so that thelines are not bent or torn.

• After the gas line installation is complete, use a com-mercially-available, non-corrosive leak check solution tocarefully check all gas connections for leaks.

WARNING: DO NOT USE AN OPEN FLAME TOCHECK FOR GAS LEAKS.!

Step 8. Gas Pressure RequirementsPressure requirements for Heat & Glo gas fireplaces areshown in the table below.

Pressure Natural Gas PropaneMinimum 5.0 inches 11.0 inchesInlet Pressure w.c. w.c.Maximum Inlet 14.0 inches 14.0 inchesGas Pressure w.c. w.c.Manifold 3.5 inches 10.0 inchesPressure w.c. w.c.

A one-eighth (1/8) inch (3 mm) N.P.T. plugged tapping isprovided on the inlet and outlet side of the gas control for atest gauge connection to measure the manifold pressure.Use a small flat blade screwdriver to crack open the screwin the center of the tap. Position a rubber hose over the tapto obtain the pressure reading.

The fireplace and its individual shut-off valve must bedisconnected from the gas supply piping system duringany pressure testing of the system at test pressures inexcess of one-half (1/2) psig (3.5 kPa).

The fireplace must be isolated from the gas supply pipingsystem by closing its individual shut-off valve during anypressure testing of the gas supply piping system at testpressures equal to or less than one-half (1/2) psig (3.5 kPa).

Use a wrench onshut-off valve whentightening gas line.

CONTROL VALVE

GAS LINEACCESS HOLE

GASVALVE

MANUAL SHUT-OFF

VALVE

FLEXCONNECTOR

Page 25: Models: Installers Guide 6000TRI-IPI 6000TRI-SP• Do not use any phone in your building. • Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's

Heat & Glo • 6000TRI-IPI, 6000TRI-SP • 385-901 Rev. F • 5/05 29

Figure 36. Intermittent Pilot Ignition (IPI) Wiring Diagram

IGNITION MODULE3 VAC

TRANSFORMER3 VAC

GR

NOR

G

INTERMITTENTPILOT

IGNITOR

IGNITIONMODULE

(3V)

ON/OFFWALL

SWITCH

LOW VOLTAGE

PLUG-IN3V TRANSFORMER

NEUTRAL HOT

GROUND

FLAME SPARKER/SENSOR

REMOTECONTROL

SEE NOTE 1

ORG

WHT

VALVE

PIGGYBACK ON/OFF SWITCH

WHITE WIRECAN BE

PLUGGEDINTO ANYOF #1-#5

LOCATIONSON THE

NEUTRAL SIDE

BLACK WIRE CAN BEPLUGGED INTO ANY OF

#1 - #5 LOCATIONSON THE HOT SIDE

BR

N

BR

N

VALVE

PLUG IN

GROUND TOFIREPLACECHASSIS

I

S

Figure 37. Standing Pilot (SP) Ignition Wiring Diagram

BLACK S2

ON

OFF

ON/OFFSWITCHWHITE T2

RED T1THERMOPILE

GAS VALVE

BLACK S1

3/16” PIGGYBACK CONNECTOR

THERMOCOUPLE

REMOTE SWITCHPIGTAIL

OPTIONAL WALL SWITCH,THERMOSTAT OR REMOTE

THTP

Page 26: Models: Installers Guide 6000TRI-IPI 6000TRI-SP• Do not use any phone in your building. • Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's

Heat & Glo • 6000TRI-IPI, 6000TRI-SP • 385-901 Rev. F • 5/0530

Figure 38. Fan Wiring Diagram

NOTE: IF ANY OF THE ORIGINAL WIREAS SUPPLIED WITH THE APPLIANCE MUST BE REPLACED, IT MUST BE REPLACED WITH TYPE 105 C RATED WIRE.OJUNCTION BOX

VARIABLE SPEED CONTROL

TEMPERATURESENSOR SWITCH

WHT

GRN

BLK

BLK

110-120 VAC

BLOWER

BLOWER RECEPTACLEBLK

BLK

BLK

BLK

WHT

GROUND

WHT

BLK

BLK

BLK

BLOWERSENSORSWITCH

“FAN”RECEPTACLE SPEED

CONTROL

NOTE: Electrical wiring must be installed by a licensedelectrician.

CAUTION: DISCONNECT REMOTE CONTROLS IF AB-SENT FOR EXTENDED TIME PERIODS. THIS WILL PRE-VENT ACCIDENTAL FIREPLACE OPERATION.

For Standing Pilot Ignition Wiring (see Figure 37).Appliance Requirements• This appliance DOES NOT require 110-120 VAC to operate.

WARNING: DO NOT CONNECT 110-120 VAC TOTHE GAS CONTROL VALVE OR WALL SWITCHOR THE APPLIANCE WILL MALFUNCTIONAND THE VALVE WILL BE DESTROYED.

!

Step 9. Wiring the FireplaceIntermittent Pilot Ignition (IPI) Wiring

3 Volt TransformerThis appliance comes with a 3 volt transformer found in themanual bag. Plug the transformer leads to the green con-trol module (see Figure 36). Then plug the transformer intothe side outlet on the junction box.

!

Appliance Requirements• This appliance DOES NOT require 110-120 VAC to operate.

WARNING: DO NOT CONNECT 110-120 VACTO THE GAS CONTROL VALVE OR THE AP-PLIANCE WILL MALFUNCTION AND THEVALVE WILL BE DESTROYED.

Operation using Battery Power

This fireplace has an optional battery operation. The sys-tem is fully functional with the use of two “D” size batterieswithout ordinary 110-120 VAC power.Wiring to the battery pack should be left disconnected inorder to conserve battery life. In the case of a loss of power,simply connect red and black wire leads to activate batterypower (connect red to red, black to black). The fireplacecan be used as necessary. Once power (110 VAC) is re-stored, disconnect red and black wire leads to extend bat-tery life.

Optional AccessoriesOptional fan and remote control kits require that 110-120VAC be wired to the factory installed junction box beforethe fireplace is permanently installed (see Figure 38)

Wall SwitchPosition the wall switch in the desired position on a wall.Run a maximum of 25 feet (7.8 m) or less length of 18A.W.G. minimum wire and connect it to the fireplace ON/OFF switch pigtails.

CAUTION: LABEL ALL WIRES PRIOR TO DISCONNEC-TION WHEN SERVICING CONTROLS. WIRING ERRORSCAN CAUSE IMPROPER AND DANGEROUS OPERATION.VERIFY PROPER OPERATION AFTER SERVICING.

Page 27: Models: Installers Guide 6000TRI-IPI 6000TRI-SP• Do not use any phone in your building. • Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's

Heat & Glo • 6000TRI-IPI, 6000TRI-SP • 385-901 Rev. F • 5/05 31

Step 10. FinishingFigure 39 shows the minimum vertical and correspondingmaximum horizontal dimensions of fireplace mantels or othercombustible projections above the top front edge of thefireplace. See Figures 2 and 3 for other fireplace clearances.Only non-combustible materials may be used to cover theblack fireplace front.

WARNING: WHEN FINISHING THE FIREPLACE,NEVER OBSTRUCT OR MODIFY THE AIR IN-LET/OUTLET GRILLES IN ANY MANNER.

!

Figure 39.Minimum Vertical and Maximum HorizontalDimensions of Combustibles above Fireplace

CAUTION: IF JOINTS BETWEEN THE FINISHED WALLSAND THE FIREPLACE SURROUND (TOP AND SIDES)ARE SEALED, A 300° F. MINIMUM SEALANT MATE-RIAL MUST BE USED. THESE JOINTS ARE NOT RE-QUIRED TO BE SEALED. ONLY NON-COMBUSTIBLEMATERIAL (USING 300° F. MINIMUM ADHESIVE, IFNEEDED) CAN BE APPLIED AS FACING TO THE FIRE-PLACE SURROUND. SEE THE DIAGRAM BELOW.

Hearth ExtensionsA hearth extension may be desirable for aesthetic reasons.However, ANSI or CAN/CGA testing standards do not requirehearth extensions for gas fireplace appliances.

Figure 40. Sealant Material

0”

FINISH WALL MATERIAL MAY BE COMBUSTIBLE - TOP AND SIDES

0”

0”NON-COMBUSTIBLE

BOARD

HIGH TEMPERATURE (3000F/ 1490C MIN.)TOP & SIDE SEAL JOINT

Note: There are 3 metal tabs holding the non-combustibleboard in place for shipping. These tabs are to be cut off orbent back before finishing around the fireplace front.

TOP FRONT EDGE OF FIREPLACE

1” 4”9”

10”

11”

1”

2-1/2”

12”13”

14”15”

16”17”

18”

31”TO CEILING9”

10”11”

12”

8”7”

6”5”

4”3”

Page 28: Models: Installers Guide 6000TRI-IPI 6000TRI-SP• Do not use any phone in your building. • Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's

Heat & Glo • 6000TRI-IPI, 6000TRI-SP • 385-901 Rev. F • 5/0532

Installing the TrimCombustible materials may be brought up to the specifiedclearances on the side and top front edges of the fireplace,but MUST NEVER overlap onto the front face. The jointsbetween the finished wall and the fireplace top and sidescan only be sealed with a 300° F. (149° C) minimum sealant.

WARNING: WHEN FINISHING THE FIREPLACE,NEVER OBSTRUCT OR MODIFY THE AIR INLET/OUTLET GRILLES IN ANY MANNER.

Install optional marble and brass trim surround kits asdesired. Marble, brass, brick, tile, or other non-combustiblematerials can be used to cover up the gap between thesheet rock and the fireplace.Do not obstruct or modify the air inlet/outlet grilles. Whenoverlapping on both sides, leave enough space so that thebottom grille can be lowered and the trim door removed.

!

Step 11. Installing Trim, Logs, and Ember Material

Figure 43. Placement of the Ember Material

EMBER MATERIAL

___________________________________________

___________________________________________

Shutter Settings

NG LP

Log 3/8” 3/8”

Burner 3/16” FULL OPEN

• Embers CANNOT be placed directly over ports. Careshould be taken not to cover the lighting trail of ports(from back to front).

• When placing Glowing embers onto the burner careshould be taken so that the ports are not covered. Placethe embers along side the port trail, but not on or inbetween the ports (see Figure 43). Failure to follow thisprocedure will likely cause lighting and sooting problems.

Figure 41.Burner Removal

RETAININGSCREW

(BOTH SIDES)

BURNER

Placing the Ember Material

Ember material is shipped with this gas fireplace. To placethe ember material:

• Pull the four glass latches out of the groove on the glassframe. Remove glass door from the unit (see Figure 42).

Figure 42. Glass Assembly

LATCHES(BOTH BOTTOM

AND TOP)

GLASSASSEMBLY

Positioning the LogsIf the gas logs have been factory installed they should notneed to be positioned. If the logs have been packagedseparately, refer to the instructions that accompany thelogs. Save the log instructions with this manual.If sooting occurs, the logs might need to be repositionedslightly to avoid excessive flame impingement.

• Place Mystic embers on areas of base refractory awayfrom port holes. Use this material to give your fireplace arealistic ash bed.

• Save the remaining ember materials for use during fire-place servicing.

• Replace the glass door and a front trim door on the unit.• Pull out and latch the glass clips into the groove on the

glass frame.

Glass Specifications:6000TRI-SP: TEMPERED6000TRI-IPI: TEMPERED

Heat & Glo fireplaces manufactured with tempered glassmay be installed in hazardous locations such as bathtubenclosures as defined by the CPSC. The tempered glasshas been tested and certified to the requirements of ANSIZ97.1-1984 and CPSC 16 CFR 1202. (Safety Glazing Certi-fication Council SGCC # 1595 and 1597. Architectural Test-ing, Inc. Reports 02-31919.01 and 02-31917.01.)

Page 29: Models: Installers Guide 6000TRI-IPI 6000TRI-SP• Do not use any phone in your building. • Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's

Heat & Glo • 6000TRI-IPI, 6000TRI-SP • 385-901 Rev. F • 5/05 33

Step 12. Before Lighting the FireplaceBefore lighting the fireplace, be sure to do the following:Remove all paperwork from underneath the fireplace.Review safety warnings and cautions• Read the Safety and Warning Information section at

the beginning of this Installers Guide.Double-check for gas leaks• Before lighting the fireplace, double-check the unit for

possible gas leaks.Double-check vent terminations and front grilles for

obstructions.• Before lighting the fireplace, double-check the unit for

possible obstructions that could be blocking the vent ter-minations or the front grilles.

Double-check for faulty components• Any component that is found to be faulty MUST BE re-

placed with an approved component. Tampering with thefireplace components is DANGEROUS and voids all war-ranties.

A small amount of air will be in the gas supply lines. Whenfirst lighting the fireplace, it will take a few minutes for thelines to purge themselves of this air. Once the purging iscomplete, the fireplace will light and will operate normally.Subsequent lightings of the fireplace will not require thispurging of air from the gas supply lines, unless the gasvalve has been turned to the OFF position, in whichcase the air would have to be purged.

Air Shutter SettingThis fireplace has an adjustable air shutter (which controlsthe primary air) factory set for the minimum vertical vent run(see Figure 44). If your installation has more than theminimum required vertical vent length, adjustment of the airshutter may be necessary to obtain optimal flameappearance. This should be adjusted by a qualifiedinstaller at the time of installation.

By pushing the air shutter handle in, you will be closing theair shutter. To adjust loosen the wing nut. Care should betaken when adjusting the air shutter so as not to cause thefireplace to soot. If sooting occurs the air shutter will needto be opened by pulling the handle out. When finished tightenwing nut.

Figure 44.

AIR SHUTTERWING NUT

This statement is in compliance with SPCS 16 CFR Sec-tion 1201.5 “Certification and labeling requirements” whichrefers to 15 USC 2063 stating “…Such certificate shall ac-company the product or shall otherwise be furnished to anydistributor or retailer to whom the product is delivered.”

Some local building codes require the use of tempered glasswith permanent marking in such locations. Glass meetingthis requirement is available from the factory. Please con-tact your dealer or distributor to order.

During this break-in period it is recommended that somewindows in the house be opened for air circulation. This willhelp avoid setting off smoke detectors, and help eliminateany odors associated with the fireplace’s initial burning.

NOTE: The fireplace should be run 3 to 4 hours on theinitial start-up. Turn it off and let it cool completely. Removeand clean the glass. Replace the glass and run the fireplacefor an additional 8 hours. This will help to cure the productsused in the paint and logs.

Page 30: Models: Installers Guide 6000TRI-IPI 6000TRI-SP• Do not use any phone in your building. • Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's

Heat & Glo • 6000TRI-IPI, 6000TRI-SP • 385-901 Rev. F • 5/0534

4 Maintaining and Servicing Your Fireplace

Fireplace MaintenanceAlthough the frequency of your fireplace servicing and main-tenance will depend on use and the type of installation, youshould have a qualified service technician perform an appli-ance check-up at the beginning of each heating season.See the table below for specific guidelines regarding eachfireplace maintenance task.

IMPORTANT: TURN OFF THE GAS BEFORE SERVICINGYOUR FIREPLACE.

Replacing old ember materialFrequency: Once annually, during the checkup.By: Qualified service technician.Task: Brush away loose ember material near the burner.Replace old ember material with new Mystic Ember pieces.Save the remaining ember material and repeat this procedureat your next servicing. For more information, see PlacingEmber Material.

Cleaning Burner and ControlsFrequency: Once annually.By: Qualified service technician.Task: Brush or vacuum the control compartment, fireplacelogs and burner areas surrounding the logs.

Cleaning Flame Sensor Rod (IPI Systems)Frequency: Annually.By: Qualified service technician.Task: Make a visual check of the straight flame sensor rod(see Figure 33). Use emery cloth to carefully remove anyexisting film or white deposits.

Checking Flame Patterns, Flame HeightFrequency: Periodically.By: Qualified service technician/Home owner.Task: Make a visual check of your fireplace’s flame pat-terns. Make sure the flames are steady - not lifting orfloating. See Figure 45. The flame sensor (IPI) or thermo-pile/thermocouple tips should be covered with flame. SeeFigure 34.

Figure 45.Burner Flame Patterns

MAKE SURE THE FLAMESARE STEADY—NOTLIFTING OR FLOATING.

Checking Vent SystemFrequency: Before initial use and at least annuallythereafter, more frequently if possible.By: Qualified service technician/Home owner.Task: Inspect the external vent cap on a regular basis toensure that no debris is interfering with the flow of air. Inspectentire vent system for proper function.

Cleaning Glass DoorFrequency: After the first 3 to 4 hours of use. As neces-sary after initial cleaning.By: Home owner.Task: Remove and clean glass after the first 3 to 4 hours ofuse. After the initial cleaning, clean as necessary, particu-larly after adding new ember (flame colorant) material. Filmdeposits on the inside of the glass door should be cleanedoff using a household glass cleaner. NOTE: DO NOT handleor attempt to clean the door when it is hot and DONOT use abrasive cleaners.

!

!

Step 13. Lighting the FireplaceYou’ve reviewed all safety warnings, you’ve checked thefireplace for gas leaks, you know the vent system isunobstructed, and you’ve checked for faulty components.Now you’re ready to light the fireplace.

WARNING: PLEASE REFER TO THE USER’SMANUAL FOR ALL CAUTIONS, SAFETY, AND

WARNING INFORMATION PERTAINING TO THELIGHTING AND OPERATION OF THE FIREPLACE.

After the InstallationLEAVE THIS INSTALLATION MANUAL WITHTHE APPLIANCE FOR FUTURE REFERENCE.


Recommended