+ All Categories
Home > Documents > Models O20 to O50+ Models O65 to O150+ - Oxywise...Performance data is based on 7 barG inlet...

Models O20 to O50+ Models O65 to O150+ - Oxywise...Performance data is based on 7 barG inlet...

Date post: 19-Apr-2020
Category:
Upload: others
View: 4 times
Download: 0 times
Share this document with a friend
2
The premium performance The unique SEP design provides steady high flow rates of oxygen with minimum footprint requirement. Together with molecular sieve protection from moisture substantially lower the service costs, extends the lifetime and provides savings. Standard Features Colored touch screen control Built in purity analyzer for constant monitoring Modbus TCP, Ethernet connection Remote start/stop relay Data-logging via USB interface Optional add-ons Flow control valve – flow & purity adjustment Energy saving valve – reduces compressed air usage during turn down Purity control – off spec purge Sequential start/stop – one button operation SMS alarm Remote monitoring Audio-visual alarm and other www.oxywise.com [email protected] Models O20 to O50+ Models O65 to O150+
Transcript

The premium performanceThe unique SEP design provides steady high flow rates of oxygen with minimum footprint requirement. Together with molecular sieve protection from moisturesubstantially lower the service costs,extends the lifetime and provides savings.

Standard FeaturesColored touch screen controlBuilt in purity analyzer for constant monitoringModbus TCP, Ethernet connectionRemote start/stop relayData-logging via USB interface

Optional add-onsFlow control valve – flow & purity adjustmentEnergy saving valve – reduces compressed air usage during turn downPurity control – off spec purgeSequential start/stop – one button operationSMS alarmRemote monitoringAudio-visual alarmand other

[email protected]

Models O20 to O50+ Models O65 to O150+

KEY BenefitsZeolite anti-crush designNo channeling effectMinimized footprintMolecular sieve protectionSiemens based control systemStainless steel pipingDesigned for dynamic pressure loading

[email protected]

Typical applicationsCutting/WeldingFish farmingGlass productionGold leachingHealth-careOzone productionVeterinaryWater treatment

Model

O20O20+O27O27+O35O35+O50O50+O65O65+O80O80+O100O100+O125O125+O150O150+

Oxygen capacity

m3/h10,111,414,615,518,720,323,326,232,137,340,946,152,557,264,270,079,386,9

kg/h13,515,219,420,724,827,031,034,942,749,654,461,369,976,185,493,1

105,5115,6

kg/h12,614,218,119,323,225,229,032,639,946,450,857,365,371,179,887,098,6108,0

m3/h9,510,713,614,517,418,921,824,530,034,938,243,149,153,560,065,474,181,2

kg/h11,312,816,317,420,922,726,129,335,941,845,751,658,864,071,878,388,797,2

m3/h8,59,612,213,115,717,119,622,127,031,434,438,844,248,154,058,966,773,1

Dimensions(LxWxH)

cm

105x95x210

115x90x226

125x95x220

155x130x230

165x135x235

195x125x225

195x125x250

205x165x315

185x165x360

Weight

kg

750

1000

1100

1800

2300

2800

3000

3300

4000

Notes

Performance data is based on 7 barG inlet pressure and 20°C to 30°C ambient temperature.

Flow stated in cubic meter (m3) is with reference conditions, Temperature: 20°C, Pressure: 1.013 barA.

Conversion factor for m3 with reference conditions, Temperature: 0°C, Pressure: 1.013 barA is 0.69 m3/kg.

Designs and specifications are subject to change without notice or obligation.

Operating conditionsAmbient temperature rangeOxygen outlet pressure Oxygen dew point Air inlet pressure Inlet air quality Pressure dew pointFiltration gradePower supply

5°C to 50°C4 to 6 barG-50°C ( -70°C)7.5 to 10 barGISO: 8573.1:2010 class 1.4.1.3°C0.01 micron110-240V / 50-60Hz

H

L

W

90% 93% 95%


Recommended