20
heat pumps MODERN R290 PROPANE
Transcript
Page 1: MODERN heat pumps - HKS Lazar

heat pumps

MODERN

R290PROPANE

Page 2: MODERN heat pumps - HKS Lazar

heatpumps

MODERN

High quality is a core area of HKS LAZAR strat-

egy: from the design, manufacture until

maintenance service.

Top quality

All components are delivered by reputable suppliers

Strict quality control at any phase of production.

Automatic operation.

Extraordinary noise reduction.

Compatible with Internet.

Colour control touch panel.

Cascade heat pumps operation possible

Two heating circuits, and extension possible.

Compatible with wireless thermostat.

Hot water circulation

One of the main priorities for HKS LAZAR is client’s satisfaction.

Comfort

Unique designSome design options available.

A wide range of finish available: exotic wood, com-

posite wood, polycarbonate, architectural concrete.

Different design options available upon request.

Page 3: MODERN heat pumps - HKS Lazar

Caring for the natural environment is one of the pri-

ority mission HKS LAZAR, that is why our heat

pumps operate on the natural refrigerant R290

(propane). This gas is neutral to the ozone layer

and has a negligible global warming potential

of GWP = 3 (for comparison, the GWP of the

most popular refrigerant R410A is 2088). This is

undoubtedly a great relief for our environment.

However, users will also benefit from having a heat

pump running on R290. There is no obligation to register this

type of equipment and to pay for emissions*. And supple-

menting the losses of R290 is much cheaper, given the rapid

increase in f-gases prices related to the progressive restric-

tions in their production and use. Above all there is no concern

about the necessity to withdraw our pump from use, as it may

be in the case of pumps operating on fluorinated gases (f-gas-

es, eg R410A).

Natural refrigerant R290 (propane)

EfficiencyVery high COP up to 4.78.

No registration or gas-emission fees*.

Wide operation range – prevents use

of other heat sources.

Professional license not required for

installation*.

Programmable weekly operation.

Temperature control.

EcologyCarbon-free heating.

Renewable heat source.

Ozone-friendly R290 gas (ODP=0) that features with low global warming

impact (GWP =3).

* - depends on local laws

Page 4: MODERN heat pumps - HKS Lazar

Uniquedesign

ASAnthracite | Silver

AAAnthracite | Anthracite

AWCAnthracite | Composite

wood

AWIAnthracite | Iroco exotic

wood

Page 5: MODERN heat pumps - HKS Lazar

ACAnthracite | Architectural

concrete

GCGrey |

Architectural concrete

GWCGrey | Composite

wood

GSGrey | Silver

GGGrey | Grey

GWIGrey | Iroco exotic

wood

Page 6: MODERN heat pumps - HKS Lazar

Water heating up to 62ºC

Absorbs heat from the outside air

High efficiency

Natural refrigerant – R 290

Operation at outside temperature down to -25ºC

High COP up to 4.78

Module with an internal heater

High heating output

It limits the work of the additional heat source

Big evaporator

11,5 kW - 22,2 kWPower:

HT 10heat pump

Module with a heaterThe HT10 heat pump with an internal module

for the water or glycol system consists of

an outdoor unit, an indoor unit and a commu-

nication cable.

SCOP3,899

The contents of the internal module:

controller, installation, electric heater.

The HT10 heat pump is equipped with an advanced ecoNET300 communication module as standard, which enables remote pump operation, servicing, viewing the history of parameter changes and sending e-mail messages with alarms.

Page 7: MODERN heat pumps - HKS Lazar

PC

TB

TCWU

T1, T2

H1

G1, G2

B1

O1

O2

PO1

PO2

PO3

ZT

ZC

ZW1, ZW2

ZM1

ZB1/ZB2

Heat pump

Buffer temperature sensor

DHW tank temperature sensor

Heating circuit temperature sensor

Indoor module with heater

Heaters

Heat buffer

Heating circuit 1

Heating circuit 2

Top source pump

Circuit pump 2

Circuit pump 3

Three-way valve

DHW tank

Non-return valve

Mixing valve 1

Safety valveM

O1 O2T1 T2

PO2 PO3

ZM1

ZW2B1 TB

ZB2

ZW1H1

G2

ZT

PO1

G1

ZB1

ZC

TCWU

PC

Hot water circuit

Cold water circuit

DISTRIBUTOR

The outdoor unit is a monobloc heating pump

made of the highest quality components and

a modern cooling system manufactured in ac-

cordance with COCH module A2 accreditation,

which guarantees the highest quality and safety.

The indoor unit includes a controller that gives

the user many possibilities, electric installation

and auxiliary electric heater.

The units are connected by the supplied com-

munication cable and the hydraulic system.

Control module with heater

Page 8: MODERN heat pumps - HKS Lazar

Water heating up to 62ºC

Absorbs heat from the outside air

High efficiency

Natural refrigerant – R 290

Operation at outside temperature down to -25ºC

High COP up to 4.78

Internal Smart Module

High heating output

It limits the work of the additional heat source

Big evaporator

11,5 kW - 22,2 kWPower:

HT 10heat pump

Module SmartHT10 heat pump with Smart indoor module for

water or glycol circuit. In this configuration,

the HT10 heat pump consists of an outdoor unit,

a Smart indoor unit and a communication cable.

The contents of the Smart indoor module:

controller, installation, electric heater,

CH/DHW switching valve, circuit pump.

The HT10 heat pump is equipped with an advanced ecoNET300 communication module as standard, which enables remote pump operation, servicing, viewing the history of parameter changes and sending e-mail messages with alarms.

SCOP3,899

Page 9: MODERN heat pumps - HKS Lazar

PC

G1

B1

O1

O2

TB

TCWU

T1, T2

HK2

P02

P03

ZC

ZM1

ZB1

Heat Pump

Heater

Heat buffer

Heating circuit 1

Heating circuit 2

Buffer temperature sensor

DHW tank temperature sensor

Temperature sensor of the heating circuit

Internal Smart Module

Circuit pump 2

Circuit pump 3

DHW tank

Mixing valve 1

Safety valve

The outdoor unit is a monoblock heating pump

made of the highest quality components and

a modern refrigeration system manufactured in

accordance with COCH module A2 accreditation,

which guarantees the highest quality and safety.

The Smart indoor unit includes a controller

that gives the user many possibilities, an electri-

cal installation, an auxiliary electric heater and

a hydraulic system with a CH/DHW switching

valve.

The units are connected by the supplied com-

munication cable and the hydraulic system.

Smartcontrolmodule

O1 O2T1 T2

PO2 PO3

ZM1

TBB1

G1

HK2

ZB1

ZC

TCWU

PC

Hot water circuit

Cold water circuit

DISTRIBUTOR

Page 10: MODERN heat pumps - HKS Lazar

Water heating up to 62ºC

Absorbs heat from the outside air

High efficiency

Natural refrigerant – R 290

Operation at outside temperature down to -25ºC

Internal SmartSplit Module

Big evaporator

High heating output

It limits the work of the additional heat source

High COP up to 4.78

11,5 kW - 22,2 kWPower:

HT 10heat pump

Anti-Freeze Module SmartSplitHT10 heat pump with SmartSplit indoor module

for water / glycol circuit consists of outdoor

unit, SmartSplit indoor unit and communication

cable.

The contents of the SmartSplit indoor module:

controller, installation, electric heater,

CH/DHW switching valve, plate exchanger, CH

circuit pump, PC circuit pump, glycol circuit

expansion vessel.

The HT10 heat pump is equipped with an advanced ecoNET300 communication module as standard, which enables remote pump operation, servicing, viewing the history of parameter changes and sending e-mail messages with alarms.

SCOP3,899

Page 11: MODERN heat pumps - HKS Lazar

PC

G1

B1

O1

O2

TB

TCWU

T1, T2

HK2

PO2

PO3

ZC

ZM1

ZB1

Heat Pump

Heater

Heat buffer

Heating circuit 1

Heating circuit 2

Buffer temperature sensor

DHW tank temperature sensor

Temperature sensor of the heating circuit

Internal Smart Split Module

Circuit pump 2

Circuit pump 3

DHW tank

Mixing valve 1

Safety valve

The outdoor unit is a monobloc heating pump

made of the highest quality components and

a modern cooling system manufactured in accord-

ance with COCH module A2 accreditation, which

guarantees the highest quality and safety.

The SmartSplit indoor unit includes a con-

troller that gives the user many possibilities,

electrical installation, auxiliary electric heater,

CH/DHW switching valve and a hydraulic system

separating the external and internal installation.

As a result, the installation outside the building

can be filled with glycol to protect it against

freezing, while the installation inside the build-

ing can be filled with water.

The units are connected with the supplied com-

munication cable and the hydraulic system.SmartSplit Anti-Freeze Control Module

O1 O2T1 T2

PO2 PO3

ZM1

TBB1

G1

HK2

ZB1

ZC

TCWU

PC

Cold water circuit

Hot water circuit

Glycol

DISTRIBUTOR

Page 12: MODERN heat pumps - HKS Lazar

Product card

Special precautions when assem-

bling, installing or maintaining the

heat pump. Observe all assembly, in-

stallation and maintenance require-

ments in the device’s instruction

manual.

POWER / COP A7 / W35:

POWER / COP A7 / W65:

POWER / COP A2 / W35:

POWER / COP A-7 / W35:

POWER / COP A-15 / W35:

POWER / COP A-15 / W55:

Communication cable:

Working temperature range:

Maximum flow temperature:

Refrigerant amount:

Power:

Weight:

Dimensions:

Hydraulic connection:

Indoor module with 2-9 kW flow heater:

Internal Smart Module:

Internal SmartSplit Module:

11,5 kW / 4,78

10,1 kW / 2,75

9,1 kW / 4,0

7,1 kW / 3,0

6,1 kW / 2,64

5,7 kW / 1,76

YES

-25ºC ÷ 35ºC

62 ºC

2,0 kg

3x400 V lub 1~230 V

180kg

810 x 1380 x 810

G5/4

YES

14,1 kW

12,8 kW

13,2 kW

9,7 kW

7,5 kW

7 kW

YES

-25ºC ÷ 35ºC

62 ºC

2,1 kg

3x400 V lub 1~230 V

180kg

810 x 1380 x 810

G5/4

YES

17,7 kW

15 kW

15,3 kW

11,3 kW

8,7 kW

8,3 kW

YES

-25ºC ÷ 35ºC

62 ºC

2,2 kg

3 x 400 V

185kg

810 x 1380 x 810

G5/4

YES

22,2 kW

18,8 kW

19,2 kW

14,2 kW

11 kW

10,2 kW

YES

-25ºC ÷ 35ºC

62 ºC

2,4 kg

3 x 400 V

190kg

810 x 1380 x 810

G5/4

YES

HT 10 / 12 HT 10 / 14 HT 10 / 16 HT 10 / 20

ENERGY EF. CLASSPOWER [COOL CLIMATE]

POWER [TEMPERATE CLIMATE]POWER [WARM CLIMATE]

ηs [COOL CLIMETE]ηs [TEMPERATE CLIMATE]

HT 10 / 12A++

10kW12kW14kW134%155%

HT 10 / 14A++

12kW14kW16kW135%154%

HT 10 / 16A++

14kW16kW20kW136%153%

HT 10 / 20A++

16kW20kW22kW135%154%

ηs [WARM CLIMATE]

Qhe [COOL CLIMETE]

Qhe [TEMPERATE CLIMATE]

Qhe [WARM CLIMATE]

LWA

HT 10 / 12180%

4883 kWh

4192 kWh

3620 kWh

54 dB

HT 10 / 14178%

4892 kWh

4208 kWh

3632 kWh

54 dB

HT 10 / 16175%

4558 kWh

4235 kWh

3780 kWh

54 dB

HT 10 / 20170%

4576 kWh

4235 kWh

3874 kWh

54 dB

Special precautions when assem-

bling, installing or maintaining

the heat pump: Observe all as-

sembly, installation and mainte-

nance requirements in the equip-

ment manual.

* - depending on the heat pump model

*

Page 13: MODERN heat pumps - HKS Lazar
Page 14: MODERN heat pumps - HKS Lazar

Tanks

NOMINAL CAPACITYMAXIMUM TEMPERATURE AND

OPERATING PRESSURE OF THE TANKINSULATION

WEIGHTENERGY CLASS

TB01 / 200200

66C

TB01 / 300 TB01 / 500300

PUR85C

500

108C

TB01 / 400 TB01 / 600400

101C

600

Removable124C

TB01 / 800800

165C

95ºC / 3 Bar

Special precautions for assembly,

installation or maintenance of the

buffer tank: All installation, installa-

tion and maintenance requirements

contained in the device’s instruction

manual must be observed.

NOMINAL CAPACITYSPIRO COIL – SURFACESPIRO COIL – CAPACITY

SPIRO COIL MAXIMUM WORKING TEMP. AND PRESSIRE

WATER TANK MAXIMUM WORKING TEMP. AND PRESSURE

INSULATIONWEIGHT

OPTIONAL ELECTRIC HEATING ELEMENT

ENERGY CLASS

NOMINAL CAPACITYSPIRO COIL – SURFACESPIRO COIL – CAPACITY

LOWER COIL – SURFACELOWER COIL – CAPACITY

SPIRO COIL MAXIMUM WORKING TEMP. AND PRESSIRE

COIL MAXIMUM WORKING TEMP. AND PRESSIRE

WATER TANK MAXIMUM WORKING TEMP. AND PRESSURE

INSULATIONWEIGHT

OPTIONAL ELECTRIC HEATING ELEMENT

ENERGY CLASS

TH02 / 300 HH02 / 800 / 5 / 2,8TH02 / 500 / 5 TH02 / 800 / 53004,018

116

C

8005,0232,814,3

95ºC / 6 Bar

95ºC / 6 Bar

95ºC / 3 Bar Removable

237G.K.2,0(6/4) / G.K.4,5(6/4) / G.K.6,0(6/4)

G.K.9,0(6/4) / G.K.12 (6/4) C

5005,023

126

C

8005,023

Removable180

C

95ºC / 6 Bar

G.K.2,0(6/4) / G.K.4,5(6/4) / G.K.6,0(6/4) G.K.9,0(6/4)

G.K.12 (6/4)-

95ºC / 3 Bar

PUR

Special precautions for assembly, installation or maintenance of the hygienic water heater tank: All installation, installation and maintenance requirements contained in the device’s instruction manual must be observed.

without a coilbuffer tanks

They are used to store energy. Polyurethane foam insulation,

leatherette housing.

hygienic water heatertanks

They are used to store energy and produce DHW water using a corrugated

stainless steel coil. Polyurethane foam insulation, leatherette housing.

Page 15: MODERN heat pumps - HKS Lazar

MIX 3D

pump group with mixing

Distributors and pump groups

pump group without mixing

distributor

It facilitates and accelerates the execution of the

heating system, precisely regulates the supply tem-

perature, includes a circuit pump, a mixing valve

with an actuator, all built in aesthetic isolation.

without mixing 

pump group

It is designed to pump the medium in the heat-

ing installation, facilitates installation, includes

a circuit pump, all built in aesthetic insulation.

2 or 3 circuits

distributor

It facilitates the assembly of pump groups, saves

time, space and installation costs. Made of steel

with polypropylene insulation to reduce heat

loss.

pump group with mixing MIX 3D

Page 16: MODERN heat pumps - HKS Lazar

Thanks to its compact design and small dimensions, it will perfectly fit

into undeveloped, narrow spaces of the attic.

Use the space

The simplicity of the control mod-

ule, the ease of use of the touch

panel and the possibility of using a

mobile application make our device

user-friendly.

Innowacyjny system kontroli przepływu

powietrza pozwala zwiększyć sprawność

układu nawet o 30%. Wentylatory dosto-

sowują prędkość do aktualnych warunków

pracy, utrzymując zrównoważony bilans stru-

mieni powietrza nawiewanego i wywiewanego.

Be in control

The sound source is suppressed at the place where it

is generated, which makes our air handling units quiet

and efficient. An insulation technology in which closed-

cell, waterproof foam also acts as thermal and acoustic

insulation. The exposed surface absorbs the sound wave

and prevents it from being reflected.

Forget about him

Compatible with HT10 heat pump

Two-stage M5 class filters allow to obtain 40% higher

quality of filtered air compared to standard G3 and

G4 class cartridges. The actual dirty filter system

shows you when to replace the filters.

Feel the freshness

When outside temperatures are below freezing,

freezing moisture blocks the air flow. AR 10 equipped

with an anti-freeze system enables balanced ventila-

tion regardless of weather conditions.

Frost does not scare us

The new heat exchangers maintain an exchange effi-

ciency of 90%, which reduces the annual heating cost

by 30%.

High efficiencyOn cool summer evenings, you can safely bypass the

heat exchanger and enjoy the cool, clean air in the

building.

Take care of the climate

The innovative air flow control system allows you to increase

the efficiency of the system by up to 30%. The fans adjust

their speed to the current operating conditions, maintain-

ing a balanced balance of supply and exhaust air streams.

Balance is the basis

recuperationMODERN

One controller panel

One common indoor setpoint temperature

Automatic compatibility of operating modes

One common Internet System

Page 17: MODERN heat pumps - HKS Lazar

Diagram of an example installation:

Page 18: MODERN heat pumps - HKS Lazar

The modern AR 10 dispels doubts!Thanks to its compact design and small dimensions , it will perfectly fit into undeveloped, nar-

row spaces of the attic. The innovative air flow control system allows you to increase the efficiency of the system by up to 30%.

RECUPERATOR

AR 10

Air stream

Maximum heat recovery efficiency

Average annual recovery efficiency

Sound power levelat maximum efficiency

Heat exchanger

Fans

Filters

Power

Maximum current consumed by the device

Dimensions

Weight

Connection stubs

Work temp

SEC – specific energy consumption [kwh/m2/year]:

SEC class:

cool-71,82

A+

temperate-35,63

A

warm-12,27

E

Declared device type:Drive type:

Type of heat recovery system:Thermal efficiency of heat recovery [%]:

The maximum value of the air flow rate [m3/h]:Maximum fan power consumption [W]:

Sound power level [dB(A)]:

BidirectionalStepless fan speed controlDiaphragmatic88%30710050

Flow rate reference value [m3/h]:Pressure difference reference value [Pa]:

Unit power consumption [W(m3/h)]:Control type factor and control type:

Declared maximum internal and external air leakage coefficients [%]:Location and description of the visual warning before replacing the air filter:

Website with assembly instructions:

220500,32CRS = 0,85 MISC = 1,1Internal 2,1%, External 1,9%Control panelwww.hkslazar.com

AEC – annual electricity consumption [kWh/year]:

AHS – annual heating savings [kWh/year]:

cool890

8850

temperate445

4540

warm400

2060

305 m3 / h (100 Pa)

95,00 %

90,00 %

52 dB

Recair with increased efficiency, 100% countercurrent

Centrifugal with EC motors

Filter class orwat M5

230 V / 50 Hz

5,9 A

1122 / 556 / 735 mm

65 kg

200 mm

+0 do +45ºC

Page 19: MODERN heat pumps - HKS Lazar

We deliver safe, energy-efficientand eco-friendly products WWW.HKSLAZAR.COM

An exemplary diagram of a recuperation installation:

Page 20: MODERN heat pumps - HKS Lazar

heat pumps

MODERN

HKS LAZAR Spółka z o. o.

44-335 Jastrzębie-Zdrójul. Wodzisławska 15B POLAND

+48 32 47 57 123 | +48 32 47 29 578 | +48 32 47 51 960

WWW.HKSLAZAR.COM


Recommended