© 2013 GMV Eurolift. The information provided in this document is subject to change without notice. 1/4 MODERNIZATIONS Power Unit NGV-EK Range 02C13ENG006 The NGV-EK Power Units have been designed to upgrade existing hydraulic elevators with mechanical valves. You can install the latest technology of Electronic Valves NGV-EK in a fast and easy way, without making any changes to the control panel. ADVANTAGES FOR LIFT COMPANY Fast and easy modernization of existing installation, with no costs for changing control panels. Offering a quick and economical solution to the customer. Reduced cost of maintenance and service. GMV Warranty. Adjustable inspection speed, increasing security during maintenance works. Produces a customized study to reduce consumption and contracted power. USER ADVANTAGES Improved comfort during the start, running and stop phases. Improved stopping by using NGV-EK Valves. Increasing SPH (starting per hour). Integrates dual security system according to EN 81.2-A3. Reduced energy consumption of lifts up to 40% depending on installation, thanks to DRY motors, which leads to a reduction of contracted power and electricity cost. TECHNOLOGY DRY-GMV Important note: the replacement of a power unit installed under Directive 95/16/EC - 81.2 with the new NGV-EK Power Unit does not require an amendment of the control panel and any additional adjustment for EN 81.2-A3. In case of substantial changes to the installation which requires an adaptation to EN81.2-A3, GMV can provide the product according to Annex A3. For any questions, please contact our sales department. POWER UNIT NGV-EK RANGE SPEED 0 5 10 15 20 25 5,57 ,5 9,2 CURRENT RATING (A) DRY GMV DRY GMV DRY GMV HYDRAULIC DRIVE POWER (kW)
Transcript
Page 1: MODERNIATIONS - local gmv...213 GMV E T . 3/4 MODERNIATIONS Power Unit NGV-EK Range OPTIONAL ACCESSORIES Electrical Emergency Downward 12 Vdc PT-01 NGV-EK range is made …

© 2013 GMV Eurolift. The information provided in this document is subject to change without notice.1/4

MODERNIZATIONS Power Unit NGV-EK Range

02C13ENG006

The NGV-EK Power Units have been designed to upgrade existing hydraulic elevators with mechanical valves. You can install the latest technology of Electronic Valves NGV-EK in a fast and easy way, without making any changes to the control panel.

ADVANTAGES FOR LIFT COMPANY

• Fast and easy modernization of existing installation, with no costs for changing control panels.

• Offering a quick and economical solution to the customer.• Reduced cost of maintenance and service.• GMV Warranty.• Adjustable inspection speed, increasing security during maintenance

works.• Produces a customized study to reduce consumption and contracted

power.

USER ADVANTAGES

• Improved comfort during the start, running and stop phases.

• Improved stopping by using NGV-EK Valves.• Increasing SPH (starting per hour).• Integrates dual security system according to EN 81.2-A3.• Reduced energy consumption of lifts up to 40% depending on installation,

thanks to DRY motors, which leads to a reduction of contracted power and electricity cost.

TECHNOLOGY DRY-GMV

Important note: the replacement of a power unit installed under Directive 95/16/EC - 81.2 with the new NGV-EK Power Unit does not require an amendment of the control panel and any additional adjustment for EN 81.2-A3.In case of substantial changes to the installation which requires an adaptation to EN81.2-A3, GMV can provide the product according to Annex A3.

For any questions, please contact our sales department.

POWER UNIT NGV-EK RANGE

SPEE

D

0

5

10

15

20

25

5,57 ,5 9,2

CU

RR

ENT

RA

TIN

G (

A)

DR

Y G

MV

DR

Y G

MV

DR

Y G

MV

HYDRAULIC DRIVE POWER (kW)

Page 2: MODERNIATIONS - local gmv...213 GMV E T . 3/4 MODERNIATIONS Power Unit NGV-EK Range OPTIONAL ACCESSORIES Electrical Emergency Downward 12 Vdc PT-01 NGV-EK range is made …

© 2013 GMV Eurolift. The information provided in this document is subject to change without notice.2/4

MODERNIZATIONS Power Unit NGV-EK Range

VALVES GROUP NGV-EK CHARACTERISTICS

ELECTRONIC CHARACTERISTICS

TECHNICAL SPECIFICATION

Type NGV-EK - 1” 1/4

RegulationsEN 81.2 -/ EN 81.70Double safety system

Technology FLUITRONIC - Stepping System

Flow Range L/Min 55 ÷ 300 [l/min]

Maximum car speed 1 [m/s]

Maximum static pressure (full load) 45 / 4.5 [bar/MPa]

Minimum static pressure (no load) 12 / 1,2 [bar/MPa]

Flow < 250 l/min ≥ 250 l/min

Valves exit 1” 1/4 1” 1/2

Departure orientation G.V. vertical / Horizontal Horizontal

Flexible hose- 1” 1/4

stiff pipe - 35 L

Flexible hose 1” 1/2

stiff pipe42 L

Operating temperature 5 ÷ 70 ºC

Fluid type Ecological / Mineral ISO VG 46(1)

(1) Fluid recommended ensures optimal performance of the equipment.

TECHNICAL SPECIFICATIONS

Type NGV EK 01

Technology Digital fluitronic- Stepping System

Regulations EMC EN 12015 y EN 12016

Stand-by consumption 3 W

Maximum consumption 25 W

Supply voltage for electronic board 24 Vdc -5% +20% (2)

Input signals 3010 / 3010-VMP / 3010 - 2CH

Supply voltage for input signals24 ÷ 60 Vdc/AC ±10 %80 ÷ 180 Vdc ±10 %

230 Vac ±10 %

Electrical emergency lowering coil voltage (2)

12 Vdc - 2,-2 A

Location Enclosure installed on power unit(3)

Outputs to control panel3 Programmable relay outputs(minimum / maximum pressure and overload (NO/NC)

1 Fault relay output (NO/NC)

Relay outputs characteristics 2A@250Vac

Indicators LEDs status

Optional accessories Programmer / MicroSD Card

(2) ALM03 power supply is provided for powering the control board.

(3) The electronic board supplied is installed on the power unit and pre-wired toward the valves.

Page 3: MODERNIATIONS - local gmv...213 GMV E T . 3/4 MODERNIATIONS Power Unit NGV-EK Range OPTIONAL ACCESSORIES Electrical Emergency Downward 12 Vdc PT-01 NGV-EK range is made …

© 2013 GMV Eurolift. The information provided in this document is subject to change without notice.3/4

MODERNIZATIONS Power Unit NGV-EK Range

OPTIONAL ACCESSORIES

Electrical Emergency Downward 12 Vdc PT-01

NGV-EK range is made up of the following models of power unit:

MODELGL F1 GL DRY F1 DRY T2 T3(*)

Motor type SUBMERGED SUBMERGED DRY DRY SUBMERGED SUBMERGED

Frequency [Hz] 50 - 60

Motor power [KW] 2,2 ÷14.7 2,2 ÷ 14,7 2,2 ÷ 9,2 2,2 ÷ 9,2 2,2 ÷ 22 11 ÷ 29,4

Motor power [CV] 3,0 ÷ 20 3,0 ÷ 20 3,0 ÷ 12,5 3,0 ÷ 12,5 3,0 ÷ 25 3,0 ÷ 40

Rated pump flow[l/min] 55 ÷ 210 55 ÷ 210 55 ÷ 150 55 ÷ 150 55 ÷ 216 55 ÷ 300

Maximum weight [kg] 90 100 90 100 180 270

Circulating Oil [l] 75 90 75 90 150 300

Minimum Oil [l] 45 40 15 20 70 100

Total capacity [l] 120 120 90 110 220 400

(*) The power unit Type 3 is available up to 300 l/min - for higher flows contact the sales department

The power unit NGV-EK range includes as standard::• Power unit with NGV-EK (1”1/4) valve with pulsation damper• Inspection Gauge fitting according to EN 81.2• Oil temperature sensor 70 °C• Motor terminals box• Electronic board 24 Vdc with 4 outputs (3 programmables) • Shut-off valve 1” 1/4• Power supply ALM 03 - 20-230 Vac/dc• MP-ISO device for direct start• Hand pump

POWER UNITS RANGE

Page 4: MODERNIATIONS - local gmv...213 GMV E T . 3/4 MODERNIATIONS Power Unit NGV-EK Range OPTIONAL ACCESSORIES Electrical Emergency Downward 12 Vdc PT-01 NGV-EK range is made …

© 2013 GMV Eurolift. The information provided in this document is subject to change without notice.4/4

MODERNIZATIONS Power Unit NGV-EK Range

BOX NGV-EK connections box / control panelC1 VRP Chamber

C2 Inlet chamber

C3 VB Discharge chamber

C4 OS spool chamber

CARD NGV-EK control boardDAL Micro-levelingDN DownwardFLT FilterISP Inspection gauge fitting EN 81.2J JackK One-way valveM, Ma MotorM1 VRP spool

MAN Pressure gauge

ML Manual lowering buttonMP Motor - pumpMPS Pressure relief spoolNGV-EK NGV-EK Valves P OS spoolPAM Hand pumpPT Pressure transducerSM Stepping systemTO Thermostat oilTT Temperature transducerVB Flow adjustment main valveVBP By-pass valveVC Rupture valveVMD Downward solenoid valveVR One-way valve (flow)

VR1 One-way valve (inlet)VR2 One-way valve (outlet)VRP One-way valve - controlledVS1, VS10

Pressure relief valve

VSMA Valve manual / electrical

1 Regulator of the pressure safety valve (pressure limiter)10 Regulator of the pressure safety valve (hand pump)7 Regulator of the ram pressure (only 2:1 acting jacks)6 Pressure gauge shut-off valve5 Rupture valve test screw

HYDRAULIC CIRCUIT


Recommended