Modification to Log-Amp position measurement in TT2- TT10 BDI day 2003 BDI day 2003 T Bogey AB/BDI-EM T Bogey AB/BDI-EM
Transcript
Page 1: Modification to Log-Amp position measurement in TT2-TT10

Modification to Log-Ampposition measurement in TT2-TT10Modification to Log-Ampposition measurement in TT2-TT10

BDI day 2003BDI day 2003T Bogey AB/BDI-EMT Bogey AB/BDI-EM

Page 2: Modification to Log-Amp position measurement in TT2-TT10

BDI day 2003 2

OutlineOutline

TTPOS principle Recall of problems Solutions implemented in 2003 Things to be done for 2004 Conclusions

Page 3: Modification to Log-Amp position measurement in TT2-TT10

BDI day 2003 3

PrinciplePrinciple

PS

SPS

TT2

TT10

BPCL100618

BPCL100509

FT16UDC151

FT16UDC211

FT16UDC251

FT16UDC311

FT16UDC346

FT16UDC368

BPCL100407

BPCL100208

BPCL101302

BPCL101502

BPCL101902

BPCL102073

BPCL102302

BPCL102402

BPCL102573

BPCL102739

BPCL102911

BPCL102963

BMU02T

BMU10T

Trigger

Trigger

Page 4: Modification to Log-Amp position measurement in TT2-TT10

BDI day 2003 4

PrinciplePrinciple

Pickup

BP FilterLogAmp

BP FilterLogAmp

BP FilterLogAmp

BP FilterLogAmp

Up-Down

Up

Down

Left

Right

Left-Right

100 / 600 m

Op Amp Integrator ADC

Op Amp Integrator ADC

VMECrate

Tunnel Auxiliary Building

Vertical

Horizontal

Auto Trigger

Page 5: Modification to Log-Amp position measurement in TT2-TT10

BDI day 2003 5

Recall of problemsRecall of problems

Auto trigger BMU10T● Position● Lead ions (stripped)

Radiation damage (102963) Position signal with no beam Loading settings when SSC changes Remote diagnostics

Page 6: Modification to Log-Amp position measurement in TT2-TT10

BDI day 2003 6

Auto trigger BMU10Twith lead ions (stripped)Auto trigger BMU10Twith lead ions (stripped)

2002: Auto trigger works with Pb53+

(unstripped) but does not work with Pb82+ (stripped)

2003: A new electronics for the auto trigger

module solved the problem.

Page 7: Modification to Log-Amp position measurement in TT2-TT10

BDI day 2003 7

Autotrigger position for BMU10TAutotrigger position for BMU10T

1013

1015

1019

1020

1023

1024

1025

1027

1029

1030

BMU10T

2003 Problem

2004

Solution

Page 8: Modification to Log-Amp position measurement in TT2-TT10

BDI day 2003 8

Radiations damages (102963)Radiations damages (102963)

The monitor is very close to the dump

During 2002 run ~ 23 E+3 gray on the electronics module

We moved the electronics away from the BPM

No more radiation damage during 2003 (but still a problem on the vertical plane)

Page 9: Modification to Log-Amp position measurement in TT2-TT10

BDI day 2003 9

Position signal with no beamPosition signal with no beam

Without beam Log-Amp still gives an output signal

No information of intensity

Autotrigger module gives a hardware interrupt to validate the data

A software algorithm check the data

Page 10: Modification to Log-Amp position measurement in TT2-TT10

BDI day 2003 10

Loading settingsLoading settings

When SSC changes MCR have to call experts to load settings

Stephen Jackson has implemented an option on the PCR Operational Software - BI applications web page to help operation

For a new SSC specialist still needed

Page 11: Modification to Log-Amp position measurement in TT2-TT10

BDI day 2003 11

Page 12: Modification to Log-Amp position measurement in TT2-TT10

BDI day 2003 12

Page 13: Modification to Log-Amp position measurement in TT2-TT10

BDI day 2003 13

Remote timing diagnosticRemote timing diagnostic

Already exists but requires expert

Solution has to be implemented for operators

Page 14: Modification to Log-Amp position measurement in TT2-TT10

BDI day 2003 14

ConclusionsConclusions

TT2/10 experience helps us for TT40/41 CNGS electronics

Each Log-Amp will have its own autotrigger

Position and Intensity available Possibility to use the same electronics

in TT2/10 upgrade