Modular Servo System (MSS)
MATLAB 7 (R14 SP2/SP3)
MATLAB R2006a/b, R2007a, R2008a/b, R2009a PCI version
User’s Manual
www.inteco.com.pl
Modular Servo System - User’s Manual 2
COPYRIGHT NOTICE
© Inteco Sp. z o.o.
All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted, in any form or by any means, electronic, mechanical, photocopying, recording or otherwise, without the prior permission of Inteco Sp. z o.o.
ACKNOWLEDGEMENTS
Inteco acknowledges all trademarks. MICROSOFT, WINDOWS are registered trademarks of Microsoft Corporation. MATLAB, Simulink, RTWT and RTW are registered trademarks of Mathworks Inc.
Modular Servo System - User’s Manual 3
Contents
1. INTRODUCTION AND GENERAL DESCRIPTION ............ ................................................................ 5
1.1. Product overview................................................................................................................................... 5 1.2. Equipment and requirements ................................................................................................................. 6 1.3. Hardware installation............................................................................................................................. 7 1.4. Software installation .............................................................................................................................. 7
2. STARTING, TESTING AND STOPPING PROCEDURES ................................................................... 8
2.1. Starting procedure..................................................................................................................................8 2.2. Testing and troubleshooting.................................................................................................................. 8
3. SERVO CONTROL WINDOW ............................................................................................................... 13
3.1. Basic test.............................................................................................................................................. 13 3.2. Manual setup........................................................................................................................................13 3.3. RTWT Driver ...................................................................................................................................... 17 3.4. Simulation Models............................................................................................................................... 18 3.5. Identification........................................................................................................................................ 20 3.6. Demo Controllers................................................................................................................................. 20
4. MATHEMATICAL MODEL OF THE SERVO SYSTEM.......... ......................................................... 22
4.1. Linear Model ....................................................................................................................................... 22 4.2. Nonlinear model .................................................................................................................................. 24
5. RTWT MODEL......................................................................................................................................... 26
5.1. Creating a model.................................................................................................................................. 26 5.2. Code generation and the build process ................................................................................................ 28
6. BASIC ASSIGNMENTS........................................................................................................................... 31
6.1. Basic measurements............................................................................................................................. 31 6.2. Steady state characteristics of the DC servo ........................................................................................ 33 6.3. Identification in time domain............................................................................................................... 35
6.3.1. Identification task by the surface method..................................................................................... 35 6.3.2. Time domain identification experiment........................................................................................ 36
7. ADVANCED ASSIGNMENTS ................................................................................................................ 38
7.1. PID position control............................................................................................................................. 38 7.2. PID Velocity control............................................................................................................................ 48 7.3. Multivariable control design............................................................................................................... 51
7.3.1. Pole-placement method................................................................................................................ 51 7.3.2. Deadbeat controller ..................................................................................................................... 54
7.4. Optimal design method: LQ controller ................................................................................................ 58 7.4.1. The continuous case..................................................................................................................... 59 7.4.2. The discrete case.......................................................................................................................... 63
8. DESCRIPTION OF THE MODULAR SERVO CLASS PROPERTIE S............................................. 66
8.1. BaseAddress ........................................................................................................................................ 67 8.2. BitstreamVersion ................................................................................................................................. 67 8.3. Encoder................................................................................................................................................ 67 8.4. Angle ................................................................................................................................................... 68 8.5. AngleScaleCoeff.................................................................................................................................. 68 8.6. PWM.................................................................................................................................................... 68 8.7. PWMPrescaler ..................................................................................................................................... 69 8.8. Stop...................................................................................................................................................... 69 8.9. ResetEncoder ....................................................................................................................................... 69 8.10. Voltage............................................................................................................................................... 70 8.11. Therm ................................................................................................................................................ 70 8.12. ThermFlag ......................................................................................................................................... 70 8.13. Time................................................................................................................................................... 71 8.14. Quick reference table......................................................................................................................... 71
Modular Servo System - User’s Manual 4
8.15. CServo Example ................................................................................................................................ 71
9. SOME TECHNICAL DATA.................................................................................................................... 75
Modular Servo System - User’s Manual 5
Modular Servo System
1. Introduction and general description The Modular Servo System (MSS) consists of the Inteco digital servomechanism and
open-architecture software environment for real-time control experiments. The main concept of the MSS is to create a rapid and direct path from the control system design to hardware implementation. The MSS supports the real-time design and implementation of advanced control methods using MATLAB and Simulink tools and extends the MATLAB environment in the solution of digital servomechanism control problems.
The integrated software supports all phases of a control system development: • on-line process identification, • control system modelling, design and simulation, • real-time implementation of control algorithms.
The Modular Servo System uses standard PC hardware platforms and Microsoft Windows
operating systems. Besides the hardware and the related software you obtain the User’s Manual. The manual: • shows step-by-step how to design and generate your own real-time controller in
MATLAB/Simulink environment, • contains the library of ready to use real-time controllers and • includes the set of preprogrammed experiments.
1.1. Product overview
The MSS setup (Fig. 1.1) consists of several modules mounted at the metal rail and coupled with small clutches. The modules are arranged in the chain. The DC motor together with tachogenerator opens the chain. The gearbox with the output disk closes the chain. The potentiometer module is located outside the chain. For example the DC motor can drive activates the following modules: inertia, backlash, encoder module, magnetic brake and the gearbox with the output disk. The rotation angle of the DC motor shaft is measured using an incremental encoder. Anywhere the rotational angle measurement is required we can place the encoder. A tachogenerator is connected directly to the DC motor and generates a voltage signal proportional to the angular velocity.
Tachogenerator DC motor
5
Inertia load Backlash
Modular Servo System - User’s Manual 6
Encoder Magnetic brake
Gearbox with output disk
N
Fig. 1.1 The MSS setup
The servomechanism is connected to a computer where a control algorithm is realized based on measurements of angle and angular velocity. The system has no inner feedback for dead zone compensation. The accuracy of measurement of velocity is 5% while the accuracy of angle measurement is 0.1%. The armature voltage of the DC motor is controlled by PWM signal. For this reason the dimensionless control signal is the scaled input voltage,
max/)()( vtvtu = The admissible controls satisfy 1|)(| ≤tu and 12max =v [V].
The measurement system is based on RTDAC/PCI acquisition board equipped with A/D converters.
The I/O board communicates with the power interface unit. The whole logic necessary to activate and read the encoder signals and to generate the appropriate sequence of PWM pulses to control the DC motor is configured in the Xilinx chip of the RT-DAC/PCI board. All functions of the board are accessed from the Modular Servo Toolbox which operates directly in the MATLAB/Simulink environment.
Features • The set-up is fully integrated with MATLAB/Simulink and operates in real-time in
MS Windows 2000/XP. • Real-time control algorithms can be rapidly prototyped. No C code programming is
required. • The software includes complete dynamic models. • The User’s Manual contains a number of pre-programmed experiments familiarising
the user with the system in a fast way.
1.2. Equipment and requirements
The following minimum configuration is required: Hardware: • MSS including the following modules: Input Potentiometer, DC Motor with
Tachogenerator, Gearbox with output disk, Magnetic Brake, Inertia Load, Digital Encoder, Backlash module.
• Computer system based on INTEL or AMD processor. • Specialised RT-DAC/PCI-D I/O board. • Power Interface unit. Software:
Modular Servo System - User’s Manual 7
• MS Windows 2000/XP, MATLAB 7 (R14 SP2/SP3), R2006a/b, R2007a, R2008a/b or R2009a appropriate Simulink, Real Time Workshop and Real Time Windows Target toolboxes, MSS Control/Simulation Toolbox.
�
The Modular Servo Toolbox supports Matlab 7 (R14 SP2, SP3), MATLAB R2006a/b, R2007a and R2008a/b and R2009a.
Manuals: • Installation Manual • User’s Manual
�
The experiments and corresponding to them measurements have been conducted by the use of the standard INTECO system. Every new system manufactured and developed by INTECO can be slightly different to the standard. It explains why a user can obtain results that are not identical to these given in the manual.
1.3. Hardware installation
Hardware installation is described in the Installation Manual.
1.4. Software installation
Insert the installation CD and proceed step by step following displayed commands. Software installation is described in the Installation Manual.
Modular Servo System - User’s Manual 8
2. Starting, testing and stopping procedures
2.1. Starting procedure
Invoke MATLAB by double clicking on the MATLAB icon. The MATLAB command window opens. Then simply type:
Servo Servo Control Window opens (see Fig. 2.1). The pushbuttons indicate actions that execute
callback routines when the user selects a menu item.
Fig. 2.1 The Servo Control Window
The Servo Control Window contains: testing tools, drivers, models and demo applications. See section 3 for a detailed description.
2.2. Testing and troubleshooting
This section explains how to perform the tests. These tests allow checking if mechanical assembling and wiring has been done correctly. The tests have to be performed obligatorily after assembling the system. They are also necessary if an incorrect operation of the system takes place. The tests are helpful to look for reasons of errors when the system fails. The tests have been designed to validate the existence and sequence of measurements and controls. They do not relate to accuracy of the signals.
First, you have to be aware that all signals are transferred in a proper way. Five testing
steps are applied.
Modular Servo System - User’s Manual 9
• Double click the Basic Tests button. The following window appears (Fig. 2.2):
Fig. 2.2 The Basic Tests window
The first step in testing of the MSS is to check if the RT-DAC/PCI I/O board is installed properly.
• Double click the Detect RTDAC/PCI board button. One of the messages shown in Fig. 2.3
opens. If the board has been correctly installed, the base address, and number of logic version of the board are displayed.
Fig. 2.3 Result of the step 1
If the board is not detected check if the board is put into the slot properly. The boards are tested very precisely before sending to a customer and only wrong assembly procedure invokes errors.
In the next step one can reset encoders. One sets the initial position of the servo system. • Double click the Reset Angle Encoders button. When the window (Fig. 2.4) opens
click the Yes option. The encoders are reset and zero position of the servo system are stored.
Modular Servo System - User’s Manual 10
Fig. 2.4 The Reset Encoders window
The next step of the testing procedure refers to the angle measurement. • Double click the Check Angles button, next click the Yes button and rotate the inertia
load by hand. The rotational angle of the inertia is measured and displayed (Fig. 2.5 ).
Fig. 2.5 Angle measurement test
• To check whether the potentiometer works correctly double click the Check Reference Pot button. Next click the Yes and turn the potentiometer right and left.
Fig. 2.6 shows an example of the proper measurements of the potentiometer position.
Modular Servo System - User’s Manual 11
Fig. 2.6 Position of the reference potentiometer
In the next step of the basic tests one can check whether the control and measurements of
the angle and velocity in MSS are correct. This experiment is not performed in real-time mode.
• Double click the Control Impulse Response button and start experiment clicking the Yes button.
The results of experiments are shown in Fig. 2.7. The control impulse has a square wave form. The first part of the control signal is positive, and the second one is negative. Note that angle and velocity signals are positive at the beginning and next fall down to the negative values. It means that the measurements are correct.
Modular Servo System - User’s Manual 12
Fig. 2.7 The response of the system
Modular Servo System - User’s Manual 13
3. Servo Control Window The user has a quick access to all basic functions of the modular servo control system from
the Servo Control Window. It includes tests, drivers, models and application examples. Type at the Matlab prompt servo command and Servo Control Window shown in Fig. 2.1
opens. Simultaneously start.m m-file is executed which set the default values of the coefficients of the MSS: 186=sK [rad/s] and 04.1=sT [s]. Also the sampling time 0T is set
equal to 0.002 [s]. The window contains four groups of the menu items: • Tools - Basic Test, Manual Setup, Reset Encoders and Stop Experiment, • Drivers - RTWT Device Driver, • Simulation Models: linear and nonlinear, • Identification - Basic Measurements, Steady-State Characteristics and Time Domain
Identification, • Demo Controllers –PID Controller and State Feedback Controller applied to a
position control and PID controller applied to a velocity control.
3.1. Basic test
The Basic Test tool was described in the previous section.
3.2. Manual setup
The Servo Manual Setup program gives access to the basic parameters of the laboratory modular servo setup. The most important data transferred from the RT-DAC/PCI board and the measurements of the servo may be visualised. Moreover, the control signals can be set. Double click the Manual Setup button and the screen shown in Fig. 3.1 opens.
The application contains four frames: • RT-DAC/PCI board, • Encoders, • Control and • Analog inputs.
All data presented by the Servo Manual Setup program are updated 10 times per second.
• RT-DAC/PCI board frame The RT-DAC/PCI board frame presents the main parameters of the RT-DAC/PCI I/O
board. No of detected boards Presents the number of detected RT-DAC/PCI boards. If the number is equal to zero it
means that the software has not detect any RT-DAC/PCI board. When more then one board is detected the Board list must be used to select the board that communicates with the MSS control program.
Modular Servo System - User’s Manual 14
Board Contains the list applied to select the board currently used by the program. The list
contains a single entry for each RT-DAC/PCI board installed in the computer. A new selection at the list automatically changes values of the remaining parameters.
Fig. 3.1 View of the Servo Manual Setup window
Bus number Displays the number of the PCI bus where the current RT-DAC/PCI board is plugged-in.
The parameter may be useful to distinguish boards, when more then one board is used. Slot number The number of the PCI slot where the current RT-DAC/PCI board is plugged-in. The
parameter may be useful to distinguish boards, when more then one board is used. Base address The base address of the selected RT-DAC/PCI board. The RT-DAC/PCI board occupies
256 bytes of the I/O address space of the microprocessor. The base address is equal to the beginning of the occupied I/O range. The I/O space is assigned to the board by the computer operating system and may differ from one computer to another.
The base address is given in the decimal and hexadecimal forms. Logic version The number of the configuration logic of the on-board FPGA chip. A logic version
corresponds to the configuration of the RT-DAC/PCI boards defined by this logic. Application
Modular Servo System - User’s Manual 15
The name of the application the board is dedicated for. The name contains four characters. In the case of the MSS it has to be SERV string.
I/O driver status The status of the driver that allows the access to the I/O address space of the
microprocessor. The status displayed has to be OK string. In other case the driver HAS TO BE INSTALLED.
• Encoders frame
The state of the encoder channels is given in the Encoder frame. Channel 0, Channel 1 The values of the encoder counters, the angles expressed in radians and the encoder reset
flags are displayed in the Channel 0 and Channel 1 row. In this version MSS may use a single encoder module. In such a case only one channel presents the current data.
Value The values of the encoder counters are given in the respective columns. The values are 24-
bit integer numbers. When an encoder remains in the reset state the corresponding value is equal to zero.
Angle [rad] The angular positions of the encoders expressed in radians are given in the respective
columns. When the encoder remains in the reset state the corresponding angle is equal to zero. Reset When the checkbox is selected the corresponding encoder remains in the reset state. The
checkbox has to be unchecked to allow the encoder to count the position.
• Control frame
The Control frame allows to change the control signal. Edit field, slider The control edit box and the slider are applied to set a new control value. The control value
may vary from –1.0 to 1.0. STOP The pushbutton is applied to switch off the control signal. When pressed the control value
is set to zero. PWM prescaler The divider of the PWM reference signal. The frequency of the PWM control is equal to:
][)1(
40KHz
erPWMprescalf pwm +
=
Thermal flag / status
Modular Servo System - User’s Manual 16
The thermal flag and the thermal status of the power amplifier. If the thermal status box is checked the power interface is overheated. If the thermal flag is set and the power interface is overheated the RT-DAC/PCI board automatically switches off the PWM control signal.
• Analog inputs frame
The Analog inputs frame displays two measured analog signals. Potentiometer Presents the voltage at the output of the potentiometer block. Tacho Presents the voltage at the output of the tachogenerator.
Modular Servo System - User’s Manual 17
3.3. RTWT Driver
The main driver is located in the RTWT Device Driver column. The driver is a software “go-between” for the real-time MATLAB environment and the RT-DAC/PCI I/O board. This driver serves the control and measurement signals. Click the Modular Servo Device Driver button and the driver window opens (Fig. 3.2).
Fig. 3.2 RTWT Device Driver
When one wants to build his own application he has to copy this driver to a new Simulink diagram.
�
Do not introduce changes inside the original driver. They can be done only inside its copy!
The device driver has two inputs: control [ ]11)( +−⊂tu and signal Reset. If the Reset
signal changes to one the encoders are reset and do not work. If the Reset signal is equal to zero encoders work in the standard way. It means when switching occurs, encoders reset and start measure when the switch returns to the zero (normal) position. It is important that the Reset switch works only when the real-time code is executed.
Modular Servo System - User’s Manual 18
The mask of the Servo block
(presented in Fig. 3.3) contains base address of the RT-DAC/PCI board (automatically detected with the help RTDACPCIBaseAddress function) and the sampling period which default value is set to 0.002 sec. If one wants to change the default sampling time he must do it in this mask also.
Fig. 3.3 Mask of the device driver
The details of the device driver are depicted in Fig. 3.4. The driver uses functions which
communicates directly with a logic applied at the RTDAC/PCI board. Notice, that the driver is ready to use a second (optional) encoder, as well.
Measurements
Control
Parameters
3Set-up
2Tacho
1A Angle
1
ThermFlagSource
1
ThermFlagGain
Servo_ThermFlag
ThermFlag
Servo_PWMTherm
Therm Status
1
0.25s+1
Simple filter
Saturation
1
ResetEncoderGain
Servo_ResetEncoder
ResetEncoder
servo_analoginputs
RT-DACAnalog Inputs1
2
PWMPrescalerSource
1
PWMPrescalerGain
Servo_PWMPrescaler
PWMPrescaler
1
PWMGain
1
PWM Therm Status
Servo_PWM
PWM
Mux
1
Encoder1024 PPR
Servo_Encoder
Encoder
0
Display Version
0
Display Therm Flag
0
Display Status
0
Display Reset
0
Display Prescaler
0
Display PWM
0
Display Encoder
Demux
Demux
-K-
Convert to rad/s
-K-
Convert to rad
Servo_BitstreamVersion
Bitstream Version
2Reset Encoder
1PWM Control
Fig. 3.4 Interior of the RTWT device driver
3.4. Simulation Models
There are two simulation models available for the servo system. The first one is a linear model and the second one is nonlinear. The linear model is used to design controllers. The nonlinear model is used to check the quality of the designed control system.
Linear and Nolinear Simulation Model – the simulation models of the servo are located
under these buttons. The external view of the simulation models is identical as the model described in the Modular Servo Device Driver except the Reset Encoder input and reference Potentiometer output which are not used in the simulation mode.
Modular Servo System - User’s Manual 19
Linear Simulation Model
Linear Simulation Model
0
Control
Angle
Velocity
Fig. 3.5 Linear Simulation Model and its mask
The vector of the initial conditions of the state variables of the simulation model is the
parameter available in the mask.
�
The model has no constrained control (as in the case of the real servo system). If you use the linear simulation model in a closed-loop remember that control should satisfy 1≤u . You can include the Saturation block to limit the control.
In the case of the nonlinear simulation model two additional parameters appear. The gain
of the model and the vector which contains the static characteristics of the servo system. Refer to section 4 for the details.
Nonlinear Simulation Model
Nonlinear Simulation Model
0
Control
Angle
Velocity
Fig. 3.6 Nonlinear Simulation Model and its mask
The simulation models are running in the normal simulation mode.
�
Choose Fixed step solver options and set Fixed-step size equal to 0.002. It is necessary because the default value of the sampling time of all real-time models is equal to 0.002 [s].
Modular Servo System - User’s Manual 20
3.5. Identification
The consecutive buttons in the group Identification of the Servo Control Window perform the following tasks:
Basic Measurements – contains a real-time Simulink model where a saw shape control
signal is given as the input of the servo system and four velocities are plotted in a scope:
• measurements reconstructed from encoder, • measurement directly from tachogenerator, • filtered tachogenerator voltage using low pass Butterworth filter, • filtered tachogenerator voltage using simple first order filter.
The experiment allows to decide which kind of velocity measurements can be used in following experiments.
Plot basic measurements push button - activates the plot_basic.m file to plot
measurements visible in the scope in the previous experiment. Static Characteristics - performs experiment aimed to measure of the static characteristics
of the loaded DC motor (angular velocity [rad/s] vs. input voltage [dimensionless] in the steady state). The characteristics can be measured for the servo system with or without magnetic brake module. The measurements are stored in the ChStat.mat file.
Plot & Save Characteristics - uses plot_stat.m file which plots measured characteristics,
performs some normalisations of the data, and saves characteristics in servo_chstat.mat file. Time Domain Identification – opens the real-time Simulink model which starts
identification based on a step system response. The button Identify Model - takes advantage of identification data and calculates
coefficients of a linear model of the servo system. The surface method is applied by the identification procedure.
3.6. Demo Controllers
The respective buttons in the column Demo Controllers perform the following tasks: Position control PID Control Continous - contains the Simulink model for real-time experiments in closed-
loop with PID position controller, and simulation model of the PID controlled servo system. State Feedback Control - opens the Simulink model to start real-time experiments for
closed-loop system with state feedback. This model can be used for experiments with LQ or deadbeat controllers. Also simulation model of the closed-loop system is included under this button.
Modular Servo System - User’s Manual 21
All the Simulink models mentioned above are examples of position control problems. Calculate LQ controller – uses Servo_calc_lq.m file to obtain state feedback controller
coefficients by solving the appropriate LQ problem. In the Servo_calc_lq.m file one can set matrices of the objective function to obtain appropriate behaviour of the system.
Velocity control PID Controller - opens the Simulink model to start-real time experiments for the closed-
loop system with velocity PID controller.
Modular Servo System - User’s Manual 22
4. Mathematical model of the servo system
4.1. Linear Model
A DC motor with a negligible armature inductance (Fig. 4.1)
αω ,
iKm=τ
R
v(t) ωeK
+
-
J
β
Fig. 4.1 Diagram of the DC motor
is described by two classical equations: electrical
)()()( tKtiRtv eω+=
and mechanical
)()()( ttiKtJ m ωβω −=&
where: )(tv is the input voltage,
)(ti is the armature current, )(tω is the angular velocity of the rotor,
R is the resistance of the armature winding, J is the inertia moment of the moving parts, β is the damping coefficient due to the viscous friction,
)(tKeω is the back EMF,
and )(tiKm=τ is the electromechanical torque.
This model is linear because the static and dry kinetic friction, as well as the saturation are neglected. By combining the electrical and mechanical equations we obtain the equation of a first order inertial system
)()()( tvKttT sms +−= ωω&
where the motor time constant sT and motor gain smK are given by
mes KKR
RJT
+=
β,
me
msm KKR
KK
+=
β.
The transfer function has the form
Modular Servo System - User’s Manual 23
1)(
)()(
+==
sT
K
sv
ssG
s
smω
The transfer function for the motor position has the form:
)1()(
)()(
+==
sTs
K
sv
ssG
s
smα
The control applied in the system is a PWM signal that’s way we assume the
dimensionless control signal as the scaled input voltage max/)()( vtvtu = . The admissible
controls satisfy
1|)(| ≤tu .
Defining also maxvKK sms = we obtain transfer functions in the forms:
Velocity transfer function Angle transfer function
1)(
)()(
+==
sT
K
su
ssG
s
sω
)1()(
)()(
+==
sTs
K
su
ssG
s
sα
The model can be written using a state space notation. Let ),(col 21 xxx = be the state vector
where 1x is the angle α (in [rad]) determining the position of the motor shaft, and ω=2x is the respective angular velocity (in [rad/s]). Time t is measured in [s].
There are the following state equations
21 xx =&
buaxx += 22&
where
0,01 >=<−=
s
s
s T
K b
Ta .
The equivalent classical matrix state space notation has the form
BuAxx +=& Cxy =
where:
−=sT
A 10
10,
=
s
s
T
KB0
, IC = .
The system can be classified as a multivariable (SIMO) because it has two measurable state variables and one control variable. The parameters sT and sK must be identified by a user.
Modular Servo System - User’s Manual 24
The default values assumed for identification experiments are as follows: 12max =v [V],
04.1=sT [s], 186=sK [rad/s], which gives ]s[961.0 2−−=a , and 8.178=b ]rad/s[ 2 .
These values have been identified by the manufacturer for the DC motor with the tachogenerator loaded by the inertia module and connected to the gearbox module equipped with the output disk.
4.2. Nonlinear model
Very often small changes of the state variables are assumed. Therefore, the control system can be considered as a linear one. However, in some applications nonlinearities in the control loop have to be taken into account. This includes non-linear static characteristics such as hysteresis and saturation, which may occur if the following devices are applied: operational amplifiers, actuators, finite word length in A/D and D/A converters. Often the signal constraint first appears for the control variable. We will assume a nonlinear model of the DC motor in the form
21 xx =&
))(( 22 xgucx −=&
where the state variables 1x , 2x and control u are defined as in the linear model. The function g is the inverted steady state characteristics of the system, which can be
determined experimentally (see section 6.2). The original steady state characteristics (see Fig. 6.8) is obtained from measurements. The results of measurements undergo a preliminary treatment consisting of scaling (to express them in appropriate units) and a shift (to remove the bias). The function g is presented in Fig. 4.2. An interesting property of the g function is that it is discontinuous at zero and shows distinct effects of dry friction in a vicinity of the origin.
�
The static characteristics was obtained for the system consisting of DC motor, inertia load, encoder and gearbox modules. If a magnetic break module is added to the system a measured characteristics are quite different.
The c coefficient was identified and 206=c [rad/s].
Modular Servo System - User’s Manual 25
Fig. 4.2 Function )( 2xg is the inverted static characteristics of the servo
Modular Servo System - User’s Manual 26
5. RTWT model
In this section the process of building your own control system is described. The Real Time Windows Target (RTWT) toolbox is used. An example how to use the MSS software will be shown in section 6. In this section some hints how to proceed in the RTWT environment are given.
�
Before start, test your MATLAB configuration by bui lding and running an example of real-time application. Real-time Windows Target Toolbox includes the rtvdp.mdl model. Running this model will test the installation by running Real-Time Workshop, Real-Time Windows Target, and the Real-Time Windows Target kernel. In the MATLAB window, type
rtvdp Next, build and run the real-time model.
To build the control application that operates in the real-time mode the user has to: • create a Simulink model of the control system which consists of the Modular Servo
Device Driver and other blocks selected from the Simulink library, • build the executable file under RTWT, • start the real-time code to run from the Simulation/Start real-time code pull-down
menus.
5.1. Creating a model
The simplest way to create a Simulink model of the control system is to use one of the models available from the Servo Control Window as a template. For example, click on the Basic Measurements button and save it as MySystem.mdl name. The MySystem Simulink model is shown in Fig. 5.1.
Now, you can modify the model. You have absolute freedom to modify the model and to develop your own control system. Remember to leave the Servo driver block in the window. This is necessary to work in RTWT environment.
Though it is not obligatory, we recommend you to leave the scope. You need a scope to watch how the system runs. The saturation blocks are built in the Servo driver block. They limit currents to DC motor for safety reasons. However they are not visible for the user who may amaze at the saturation of controls. Other blocks remaining in the window are not necessary for our new project.
Creating your own model on the basis of an old example ensures that all-internal options of the model are set properly. These options are required to proceed with compiling and linking in a proper way. To put the Servo Device Driver into the real-time code a special make-file is required. This file is included in the MSS software.
Modular Servo System - User’s Manual 27
Fig. 5.1 The MySystem Simulink model
You can apply most of the blocks from the Simulink library. However, some of them cannot be used (see RTW or RTWT references manual).
The scope block properties are important for appropriate data acquisition and supervising how the system runs.
The Scope block properties are defined in the Scope property window (see Fig. 5.2). This window opens after the selection of the Scope/Properties tab. You can gather measurement data to the Matlab Workspace marking the Save data to workspace checkbox. The data is placed under Variable name. The variable format can be set as structure or matrix. The default Sampling Decimation parameter value is set to 1. This means that each measured point is plotted and saved. Often we choose the Decimation parameter value equal to 5. This is a good choice to get enough points to describe the signal behaviour and to save the computer memory. In this case the time space of the plot is equal to 0.01 [s].
Fig. 5.2 Setting the parameters of the Scope block
Modular Servo System - User’s Manual 28
When the Simulink model is ready, click the Tools/External Mode Control Panel option and next click the Signal Triggering button. The window presented in Fig. 5.3 opens. Select Select All check button, set Source as manual, set Duration equal to the number of samples you intend to collect and close the window.
Fig. 5.3 External Signal & Triggering window
5.2. Code generation and the build process
Once a model of the system has been designed the code for real-time mode can be generated, compiled, linked and downloaded into the computer.
The code is generated by the use of Target Language Compiler (TLC) (see description of the Simulink Target Language). The make-file is used to build and download object files to the target hardware automatically.
First, you have to specify the simulation parameters of your Simulink model in the Simulation parameters dialog box. The RTW page appears when you select the RTW tab (Fig. 5.4). The RTW page allows you to set the real-time build options and then to start the building process of the executable file.
Modular Servo System - User’s Manual 29
Fig. 5.4 RTW page of the Simulation parameters dialog box (MATLAB 6.5)
The system target file name is rtwin.tlc. It manages the code generation process. The servo_win_vc.tmf template make-file is devoted to C code generation using the Microsoft Visual C++ compiler. The servo_win_watc.tmf template file has to be applied if the Open Watcom 1.3 compiler is used.
If the Matlab 7.0.4 or higher version is used a third party compiler is not required. The
built-in Open Watcom compiler is used to creating real-time executable code for RTWT. The Configuration parameters page for MATLAB 7.04 is shown in Fig. 5.5. Notice that
rtwin.tmf template makefile is used. This file is default one for RTWT building process.
-
Fig. 5.5. Configuration parameters page for MATLAB 7.04 and higher versions
Modular Servo System - User’s Manual 30
The Solver page appears when you select the Solver tab (Fig. 5.6). The Solver page allows you to set the simulation parameters. Several parameters and options are available in the window. The Fixed-step size editable text box is set to 0.002 (this is the sampling period in seconds).
�
The Fixed-step solver is obligatory for real-time applications. If you use an arbitrary block from the discrete Simulink library or a block from the driver library remember that different sampling periods must have a common divider.
The Start time has to be set to 0. The solver has to be selected. In our example the fifth-
order integration method − ode5 is chosen.
Fig. 5.6 Simulation parameters
If all parameters are set properly you can start the executable building process. For this purpose press the Build push button on the RTW page (Fig. 5.4).
Successful compilation and linking processes generate the following message: ### Created Real-Time Windows Target module MySystem.rwd. ### Successful completion of Real-Time Workshop build procedure for model: MySystem Otherwise, an error massage is displayed in the MATLAB command window.
Modular Servo System - User’s Manual 31
6. Basic Assignments All experiments described in this manual are performed with servo system consisting of
the following modules: DC motor with tachogenerator, inertia load, encoder and gearbox with the output disk. In one experiment additionally the backlash module is applied.
6.1. Basic measurements
In this section quality of measurements in the servo system is concerned. The shaft angle is measured with high accuracy by an incremental encoder. If the tachogenerator is not used the shaft angular velocity must be reconstructed from the angle measurements. If the tachogenerator is used as a velocity sensor then its voltage signal comes together with disturbances, therefore it must be filtered.
Fig. 6.1 Simulink model of Basic Measurements
The Signal generator block produces a saw shape control signal for the servo system. This shape was selected to demonstrate the full range of the control values.
The velocity measurements are shown in Fig. 6.2. One can see that the most disturbed is
signal obtained directly from the tachogenerator. The reconstructed velocity (from encoder measurements of the angle) is the best one. Two types of the filters are applied: the fourth order Buterworth filter and a simple first order filter. Details and differences between the measurements are shown in Fig. 6.3 and Fig. 6.4. A user can choose which one of the velocity measurement will be used in his own real-time experiments.
Modular Servo System - User’s Manual 32
Fig. 6.2 Velocity measurements
0 10 20 30 40 50 60-200
-150
-100
-50
0
50
100
150
200Velocity measurements: red - encoder, blue - directly from tacho
time [s] press any key
40.02 40.04 40.06 40.08 40.1 40.12 40.14 40.16 40.18 40.2
-100
-95
-90
-85
-80Velocity measurements: red - encoder, blue - directly from tacho
time [s] press any key
Fig. 6.3 Comparison of the velocity measurements
Modular Servo System - User’s Manual 33
0 10 20 30 40 50 60-200
-150
-100
-50
0
50
100
150
200Filtered velocity: red - Butterworth filter, blue - simple filter
time [s] press any key 40 40.02 40.04 40.06 40.08 40.1 40.12 40.14 40.16 40.18 40.2
-94.5
-94
-93.5
-93
-92.5
-92
-91.5
-91
-90.5
Filtered velocity: red - Butterworth filter, blue - simple filter
time [s] press any key
Fig. 6.4 Comparison of the velocity measurements
6.2. Steady state characteristics of the DC servo
Double click the Static characteristics button in Servo Control Window. The window given in Fig. 6.5 opens. In this window one defines the minimal and maximal control values and a number of measured points. Also the control order can be set as: Ascending, Descending or Reverse.
Fig. 6.5 Parameters of measurement of static characteristics
The Run button starts the experiment. The constant value of the control activates the DC
motor so long as a steady state of the shaft angular velocity is achieved. Then, the velocity is measured and the control value is changed to the next constant value and DC motor is activated again. These steps are repeated to the end of the control range. Simultaneously, the measurements are displayed in the screen (see Fig. 6.6). There are two sources of DC motor velocity: the reconstruction from the incremental encoder pulses and the tachogenerator voltage. After the identification process the measurements are saved in the ChStat.mat file.
Modular Servo System - User’s Manual 34
Fig. 6.6 Visualisation of measurements the static characteristic
When the measurements are completed, close the window and double click the Plot & save button. The ChStat.mat file is loaded and the static characteristics is plotted (see Fig. 6.7). Notice that when the characteristics is measured in Reverse mode (the control is changed from –1 to +1 and in the reverse order). The plots are slightly different. Next, the characteristics are averaged and shifted to zero for a number of points to diminish influence of the dry friction. Next, the plot (see Fig. 6.6) is drawn and the characteristic is saved in the servo_chstat.mat file. If this file exists it is overwritten.
-1 -0.8 -0.6 -0.4 -0.2 0 0.2 0.4 0.6 0.8 1-200
-150
-100
-50
0
50
100
150
200Static characteristic of DC servo
u [normalised]
Ang
ular
vel
ocity
[ra
d/s]
Fig. 6.7 Collecting points of the static characteristic
Fig. 6.8 Averaged and shifted static characteristic
Building a new static characteristics is a seldom operation. Please do not forget to save the old characteristics (with an appropriate description) in a safe place. The details are included in the plot_stat.m file which executes all operations mentioned above.
Modular Servo System - User’s Manual 35
The characteristics saved in the servo_stat.mat file is used in the construction of a nonlinear model of the servo system.
6.3. Identification in time domain
The task is to find the parameters sT and sK of the linear model of the servo system
described by the transfer function
1)(
)(2 s+T
K
su
sxG(s)=
s
s= (6.1)
that the states of the model fit to the experimentally measured states. The step input signal u(t)= 1(t) is applied to the servo system and the velocity vs. time is acquired. The surface method is applied to find the system parameters.
6.3.1. Identification task by the surface method The velocity signal is denoted as )(2 tx . Applying the model (6.1) the required parameters
SS and TK can be calculated using the following relations:
∞→−==
∞→=
∫ txKKK
KT
ttxK
ss
s
s
,d))((lim where
,)(limt
0
211
2
λλ
The surface method is the useful identification algorithm in the presence of disturbances. In this case the integral formula filtrates the measurement noises. Fig. 6.9 shows a typical application of this method to a DC servo identification problem.
sK
surface 1K
t
)()(2 twtx +
Fig. 6.9 Surface method in the presence of disturbances )(tw
Modular Servo System - User’s Manual 36
6.3.2. Time domain identification experiment In this experiment MSS includes the following modules: the DC motor with
tachogenerator, inertia load, encoder module and gearbox module with the output disk. The magnetic break module can be added but in such a case the identified parameters of the system will be different.
To start the identification experiment type servo at the MATLAB prompt and Servo Control Window appears. Now, double click the Time domain identification button. The model shown in Fig. 6.10 opens.
Build model (in the case if it has not been done before). Next, select the Simulation/Connect to target option and click the Simulation/Start real-time code. The servo starts to move and one can observe the velocities displayed in the screen (see Fig. 6.11).
Fig. 6.10 Real-time Simulink model for identification
Fig. 6.11 Step response of the servo
Modular Servo System - User’s Manual 37
Click the Calculate model button. This action starts the plot_ident.m file where the surface method is applied and the parameters of the servo model are calculated. Consequently, Fig. 6.12 opens and two plots are displayed in the screen:
• velocity obtained from the measurements (red), • velocity calculated from the model (black).
At the top of the figure the obtained coefficients and the Mean square error denoted by J
corresponding to data fitting are displayed. The coefficients are also displayed in the Matlab window.
Fig. 6.12 Measured (red) and modelled (black) velocities
�
Remember that your servo can be different to the system described in this
manual. The time domain identification has to be performed before any experiment.
Modular Servo System - User’s Manual 38
7. Advanced Assignments
7.1. PID position control
A PID controller is the most common form of feedback. In process control today, more than 95% of the control loops are of a PID type, in principle a PI control. The PID controllers are today present in all areas where control is used. In our case only P and PD controllers are concerned. The servo itself behaves as an integrator.
In this section a problem of the position control of the servo is concerned. The background
to simple tuning methods is introduced. All real-time experiments related to the PID position control are performed using the
model given in Fig. 7.1.
PID controller
1
0.05s+1
Simple fil ter
SignalGenerator1
Servo
Saturation
ResetEncoders
Real-time only
1
Reset
0
Normal
-K-
Kp
-K-
Ki
-K-
Kd
rad-to-rad/s
CalculateVelocity1
Angle & Reference& velocity
Angle & ref
Angle (encoder)
Reset
v elocity (tacho)
f ilterd v elocity
control
control
Fig. 7.1 Real-time model of the servo with the PID controller
The transfer function of a continuous PID controller used in this manual has the form:
DI
p sK s
K = K
s
suK(s)= ++
)(
)(
ε
where: ε - error ,
pK - proportionality coefficient, IK - integration coefficient and DK -
derivation coefficient. P controller A goal of the control is to track a reference signal which is defined as a square wave. In
this section the P controller is investigated.
Modular Servo System - User’s Manual 39
αrefα
- )1( +s
s
sTs
KpK
Fig. 7.2 Position servo control with the P controller
The diagram of the closed loop system is shown in Fig. 7.2. It is well known that increasing gain leads to oscillations. To test the real-time system for different gains of the P controller click PID control continuous button in Servo Control Window. The model given in Fig. 7.1 opens. We start with a small value of the gain of the P controller. Type K=[0.0064 0 0] at the MATLAB prompt. It set proportional coefficient pK of the P controller. Assuming a desired
range of the change of the output disk equal to pi/2 set reference input signal equal to 25*pi/2 (it is the measured angle at the input to the gearbox). Also set frequency of the reference input to 0.05 Hz and sample time to 0.002 s. • Build the model. • Click the Simulation/Connect to target and Start real-time code options to start
experiment. Next, repeat the experiment for the new setting: 0127.0=pK and 0254.0=pK .
The results of all experiments are given in Fig. 7.3 and Fig. 7.4. Note, that oscillations of the system response appear if 0127.0=pK and 0254.0=pK .
0 5 10 15 20 25 30-80
-60
-40
-20
0
20
40
60
80Position control with P controller
time [s]
Kp=0.0127
Kp=0.0064
Kp=0.0254
Fig. 7.3 Response of the closed-loop system with the P controller
Modular Servo System - User’s Manual 40
The controls shown in Fig. 7.4 do not reach the zero value. It is due to the dead zone of the system which can be observed at the steady state characteristic shown in Fig. 6.8. The dead zone of the normalized u is in the range from -0.15 to 0.15.. Notice, that the control saturates for 0254.0=pK .
0 5 10 15 20 25 30-1
-0.8
-0.6
-0.4
-0.2
0
0.2
0.4
0.6
0.8
1Controls
time [s]
Kp=0.0127
Kp=0.0064
Kp=0.0254
Fig. 7.4 Controls for different gains of the P controller
In the table below the steady state error is shown for the gain coefficients applied in these experiments. In accordance with theory if the pK increases the steady state error decreases.
K 0.0064 0.0127 0.0254
∞ε 20 % 9.1 % 4.8 %
PD controller The main goal of the controller tuning is to obtain the standard second order system step
response. The general form of the second order transfer function is
22
2
2)(
nn
ns
sssG
ωζωω
++=
If 10 << ζ , then the step response of )(sGs exhibits an exponentially damped sinusoidal
character with the following features:
Modular Servo System - User’s Manual 41
• percentage overshoot 21
% 100 ζ
ζπ
−
−
= ep
• 2% settling time n
st ζω4=
• time to peak 21 ζω
π−
=n
pt
For given %p and st one can calculate the damping coefficient ζ and natural frequency
nω . Comparing a transfer function of the closed-loop system, which contains the coefficients
of the controller, with the standard transfer function )(sGs one can calculate the controller
coefficients.
EXAMPLE
Assume that we would like to design a PD controller for the position control of the servo system as it is shown in Fig. 7.5: Note that at the first glance the state feedback controller is
used. But remember that dt
dαω = . For this reason the applied controller is PD type.
The requirements corresponding to the dynamics of the closed-loop system are as follows:
• settling time ][ 5.2 sts ≤
• and maximal overshoot 10% ≤p
Reference Signal
-K- Ks/Ts
-K-
Kp
-K- Kd
-K- 1/Ts
e alfa ref angle
controller servo
velocity
1/s 1/s
Fig. 7.5 Position control with the PD controller
The servo system has the transfer function )1(
)(+
=sTs
KsG
s
s . The transfer function of the
PD controller is sKKsK Dp )( += . The default values of the system coefficients are
186=sK [rad/s] and 04.1=sT [s].
Closing the control system we obtain the transfer function in the form
Modular Servo System - User’s Manual 42
s
sp
s
Ds
s
sp
z
T
KK
T
KKss
T
KK
sG
++
+=
1)(
2
.
Substituting values for the coefficients into the transfer function we obtain
pD
pz KKss
KsG
846.178)9615.0 846.178(
846.178)(
2 +++= .
The following relationships are obtained by comparing the transfer function with the standard transfer function of the second order system
2 846.178 npK ω= ,
9615.0 846.1782 += Dn Kζω .
Considering the formula and the condition for the settling time ][ 5.2 sts ≤ one obtains the
inequality 0125.0≥DK . Consequently, respecting the formula and the condition 10% ≤p related to the assumed
percentage overshoot one can calculate an unknown value as 5912.0=ζ , later 7039.2=nω
and 0409.0=pK .
To check if the behaviour of the closed-loop system is consistent with requirements one can use the simulation method. Type at the Matlab prompt K=[0.0409 0 0.0125] to save the coefficients of the PD controller in the workspace. Click the PID controller & linear model button. The model depicted in Fig. 7.6 opens. Note, that the linear model of the servo is applied. The simulation results are shown in Fig. 7.7.
PID controller (simulation)
ReferenceSignal
Linear Simulation Model
-K-
Kp
-K-
Ki
-K-
Kd
Angle & Ref
e alf aref
Angle
v elocity
Fig. 7.6 Simulation model of the closed-loop system with the PD controller
Modular Servo System - User’s Manual 43
Fig. 7.7 Simulation results of the system with the PD controller
The percentage overshoot is too large, namely 16.4%. However the settling time is equal to 2.4[s] what is a satisfactory result. The steady state error is equal to 1.2% what shows that the goal of the control is satisfied but the requirement related to the percentage overshoot is missed.
Before redesigning a controller a real time experiment should be performed. Click the PID control continuous button. Click PID controller and the model presented in Fig. 7.1 opens. Build it and start the real-time code. The results are presented in Fig. 7.8. Notice, that the response of the real system always differs slightly from the simulated one.
Fig. 7.8 Results of the real-time experiment with the PD controller
Modular Servo System - User’s Manual 44
To see in details differences between the real time and simulation responses of the closed-loop system execute the servo_plot_pid.m file. This file is included in the Servo Toolbox but is accessible only from Matlab Command Window. The plot is depicted in Fig. 7.9. The table below includes the details read from the figure.
Simulation Real-time experiment
st [s] 2.4 3
%p [%] 16.5 8.14
Steady state error [%] 0.2 4.02
Fig. 7.9 Comparison of the real-time and simulation experiments with the PD controller
The overshoot of the real-time experiment is small but the steady state error is too large
and the settling time is too long. We are trying to increase proportional coefficient pK of the PD controller. It will increase
the overshoot (that is an admissible step) and decrease the steady state error (to a value which is required) and shorten the settling time what is required also.
Type at Matlab prompt: K=[0.0609 0 0.0125] and repeat the real-time experiment with the PD controller and observe the results in the scope of the model. To see all details of responses vs. time type the following commands:
a=1;b1=length(PD_C.time); t=PD_C.time(a:b); a=1; b=10/(t(2)-t(1)); %plot only first 10 seconds of r esponse t=t(a:b); plot(t,PD_C.signals(1).values(a:b,1),'b',t,PD_C.sig nals(1).va lues(a:b,2),'k');grid;
Modular Servo System - User’s Manual 45
title('Responses of: real system with corrected PD controller'); xlabel('time [s]');
The plot which is obtained is shown in Fig. 7.10 The values of the percentage overshoot,
settling time and steady state error are as follows:
5.12% =p [%] , 23.2=st [s] and 33.0=∞ε [%].
The overshoot is a little greater than the assumed one but the settling time is fine and the
steady-state error is perfect. We can conclude that the goal of the control is satisfied and that the PD controller just designed works well.
0 1 2 3 4 5 6 7 8 9 10-50
-40
-30
-20
-10
0
10
20
30
40
50Response of real system with corrected PD controller
time [s]
Fig. 7.10 Response of the real-system with the corrected PD controller
Position control with the backlash module
In this section position control problem is considered when the backlash exists in the servo
system as it is shown in Fig. 7.11.
αrefα
-
pK Backlash )1( +s
s
sTs
K
Fig. 7.11 Position servo control with the backlash and P controller
Modular Servo System - User’s Manual 46
The backlash is present in a number of mechanical and hydraulic systems. In many cases backlash is necessary to proper work of a mechanical system. A gearbox without backlash will not work if temperature rises. The backlash in a system deacreases control performance and in most applications introduces oscillations to the controlled system.
At the beginning the backlash have to be added to existing servo system. Add this module between the inertia and the encoder modules in the system chain. It is important that encoder measures an angle after the backlash module.
To test a behaviour of the real-time system with the backlash module for different gains of the P controller click PID control continuous button in Servo Control Window. The model given in Fig. 7.1 opens. Type K=[0.1024 0 0] at the MATLAB prompt. It sets the proportional coefficient pK of the
P controller. Assuming a desired range of the change of the output disk equal to pi/2 set the reference input signal equal to 25*pi/2 (it is the measured angle at the input to the gearbox). Also set the frequency of the reference input to 0.05 Hz and sample time to 0.002 [s]. • Build the model. • Click the Simulation/Connect to target and Start real-time code options to start the
experiment. The results are given in Fig. 7.12 and Fig. 7.13.
0 5 10 15 20 25 30-80
-60
-40
-20
0
20
40
60
80Position control with P controller
time [s]
Fig. 7.12 Position control with the backlash module - 1024.0=pK
Notice, that there are oscillations in the system. The oscillations are far from the harmonic shape. They are generated as the result of a limit cycle in the system. The control shown in Fig. 7.13 is saturated. It is the well known fact that decreasing the proportional gain of the controller can correct this unfavourable behaviour of the servo system.
Modular Servo System - User’s Manual 47
0 5 10 15 20 25 30-1
-0.5
0
0.5
1Controls
time [s]
Fig. 7.13 Control signal
Repeat the experiment for 0128.0=pK . The results are shown in Fig. 7.14 and Fig. 7.15.
0 5 10 15 20 25 30-60
-40
-20
0
20
40
60
80Position control with P controller
time [s]
Fig. 7.14 Position control with backlash module 0128.0=pK
Notice, that oscillations are not present in this case. The desired position is reached with 2.8% accuracy. The control does not saturate. We conclude that the closed-loop system behaviour is satisfactory.
Modular Servo System - User’s Manual 48
0 5 10 15 20 25 30-1
-0.5
0
0.5
1Controls
time [s]
Fig. 7.15 Control signal
7.2. PID Velocity control
The task of the velocity control is to keep the desired velocity in the presence of disturbances. The disturbances can be introduced as a change of the velocity reference signal or as a change of the motor load. To disturb the reference velocity the potentiometer can be used. The load disturbances can be introduced by braking slightly the inertia load of the system. In the example the load disturbances are introduced manually.
Click the Velocity control button in Servo Control Window and model shown in Fig. 7.16
opens.
PID velocity control
1
0.2s+1
Simple fi lter1
1
0.05s+1
Simple fi lter
SignalGenerator
Servo
Saturation
ResetEncoders
real-time only
1
Reset
Reference& Velocity
Control
0
Pot
PID
0
Normal
rad-to-rad/s
CalculateVelocity
Angle (encoder)
Reset
v elocity (tacho)
f ilterd v elocity
Control
Velocity & Ref erence
f iltered control
Fig. 7.16 PID velocity control in the real-time system
Modular Servo System - User’s Manual 49
Set the sine reference velocity, amplitude equal to 40 [rad/s] and frequency equal to 0.1 [Hz] . Simulation time set equal to 30 [s]. The Gain of the potentiometer set equal to zero. The coefficients of the PID controller set to the following values: 15.0=pK and 03.0=iK .
Fig. 7.17 The results of the PID velocity control
Build the model and run the real time code. The results of the experiment are given in Fig. 7.17.
One can see that the disturbances of the motor load are introduced manually after five seconds from the start and remain active in tha period of 15 seconds. Note, that the control increases in this time interval. The results are stored in the VelCtrl variable stored in the Matlab workspace.
Type at the Matlab prompt : plot(VelCtrl.time,VelCtrl.signals(1).values(:,2),'r ',VelCtrl.time,VelCtrl
.signals(1).values(:,1),'k');grid;xlabel('time [s]' );title('Reference velocity (red) - measured velocity (black)');
The plot is shown in Fig. 7.18 . In this scale the differences between the diagrams are unvisible. The details of the reference velocity and the measured velocity are shown in Fig. 7.19.
Modular Servo System - User’s Manual 50
0 5 10 15 20 25 30-50
-40
-30
-20
-10
0
10
20
30
40
50
time [s]
Reference velocity (red) - measured velocity (black)
Fig. 7.18 Reference and measured velocity
12.2 12.3 12.4 12.5 12.6 12.7 12.8 12.9
38.4
38.6
38.8
39
39.2
39.4
39.6
39.8
40
time [s]
Reference velocity (red) - measured velocity (black)
Fig. 7.19 Zoomed data
The tracking error of the velocity (at 12.5 seconds) is equal to 1%. Of course this error varies in time but it is rather small as far as the error of the velocity measurements is concerned.
Modular Servo System - User’s Manual 51
7.3. Multivariable control design
The section demonstrates how properties of a closed-loop system are influenced by the design parameters: the closed-loop roots and sampling period. Two methods of the closed-loop systems design are shown. The first is based on the pole placement and is applied for continuous systems. The second control method, known as "deadbeat control" is used for discrete systems.
7.3.1. Pole-placement method A closed-loop system with feedback gains from the states is analysed. The approach we
wish to apply is the pole placement. It means that we can change the closed-loop system roots. There are different ways of achieving this. One of the design methods is described below.
The continuous-time system is represented by the state equation:
BuAxx +=& Cxy =
The state controller realises a linear feedback control law in the form: )( yyKu d −= ,
where K is the feedback gain matrix and dy is the desired output vector.
We request that the roots of the closed system are equal to λ λ1 2, (fixed). The design methods consist in finding K that the roots of the closed-loop system are in the desired locations. That means, we assume dynamic properties of the closed system. It can be shown that there exists a linear feedback that gives a closed-loop system with roots specified if and only if the pair (A,B) is controllable. It is clear that closed-loop system has to be stable and it is a 'sine qua non' assumption of the design.
The state matrix of the closed-loop system is
)( BKCAAc −= .
For the case of the DC motor the matrix cA is given as
+−−=
s
s
s
sc
T
kK
T
kKA 21 110
,
and the characteristics equation has the form
01 122 =+++
s
s
s
s
T
kK
T
kKλλ .
By means of the feedback gains, the location of roots of the characteristics equation may be changed. From the Vieta's formula we obtain
s
s
T
kKλλ
121 =⋅
s
s
T
kKλλ
221
1)(
+−=+ ,
and we can calculate 1k and 2k from
Modular Servo System - User’s Manual 52
s
s
K
Tλλk
⋅⋅= 211
s
s
K
Tλλk
1)( 212
++−= . (7.1)
It is clear that we can require the desired behaviour of the closed-loop system but we have to keep the control between appropriate limits 1|)(| ≤tu . When the control variable saturates, it is necessary to be sure that the system behaves properly.
EXAMPLE Assume that we would like to design a closed-loop system without oscillations. A possible
selection of the roots is: 21 −=λ and 32 −=λ .
For the identified parameters (an example) 186=sK [rad/s] and 04.1=sT [s] we can
calculate 21,kk from formula (7.1) 0335.01 =k and 0226.02 =k Then, we simulate the closed-loop system with the feedback gains 21,kk . Perform the following steps:
• type K=[0.0335 0.0226] and servo at the MATLAB prompt. • Double click the State feedback control continuous and State feedback controller
buttons. The model shown in Fig. 7.20 opens. Assuming a desired range of the change of the output disk position equal to pi/2 set the reference input signal equal to 25*pi/2 (it is the measured angle at the input to the gearbox). Also set the frequency of the reference input equal to 0.1 Hz and sample time equal to 0.002 s.
• Build the model. • Click the Simulation/Connect to target and Start real-time code options to start the
experiment. The results are presented in Fig. 7.21. Notice, that the response of the system is slow and not accurate. The reference angle is reached with accuracy equal to 6% and the settling time is about 4[s].
We can change the roots of the closed-loop system to make the system faster. Assuming 41 −=λ and 52 −=λ we obtain: 1118.01 =k and 0449.02 =k .
Modular Servo System - User’s Manual 53
State feedback controller
1
0.05s+1
Simple fi l ter
SignalGenerator1
Servo
Saturation
ResetEncoders
Real-time only
1
Reset
0
Normal
-K-
-K-
rad-to-rad/s
CalculateVelocity1
Angle & Reference& velocity
Angle & ref
Angle (encoder)
Reset
v elocity (tacho)
f ilterd v elocity
control
control
Fig. 7.20 Real-time model with state feedback controller
Type at the Matlab prompt K=[0.0335 0.0226] and repeat the experiment with the new
values of 21 and kk . The experimental results are shown in Fig. 7.22. Notice, that the response of the system is faster and more accurate. The reference angle is reached with accuracy equal to 2.3% and the settling time is 2.5 [s]. These results outperform the previous one.
In both experiments the control saturates despite that the goals of the design are achieved.
Fig. 7.21 Experiment of the closed-loop system , 21 −=λ and 32 −=λ
Modular Servo System - User’s Manual 54
Fig. 7.22 Experiment of the closed-loop system , 41 −=λ and 52 −=λ
7.3.2. Deadbeat controller It is the control method unique to discrete systems in which we calculate feedback gains in
such a way that the roots of the closed system are equal to zero. This control strategy has the property that it drives the states of a closed-loop system from arbitrary values to zero in at most N steps (dim(A)=N). It is the fastest possible discrete controller.
The sampling time T0 is the only design parameter. The magnitude of the control variable u can be decreased by increasing the sampling time T0, or vice versa. For a given range of the reference variable step a suitable sample time can be determined. The main problem of the design is the saturation of the system actuators.
The discrete system is described by a discrete state equation:
].[][
][][])1[(
00
000
nTxCnTy
nTuBnTxATnx
D
DD
=
+=+
The matrices DA and DB are calculated from the continuous state-space model using the
following, well known, relations:
0ATD eA = BdteB
TAt
D
= ∫
0
0
CCD = = I .
For a discrete model of the DC motor matrices dA and dB have the form
Modular Servo System - User’s Manual 55
−
−−=
−==
−
−
−
−
)1(
))1((
0
)1(10
0
0
0
0 0
s
s
s
s
T
T
S
T
T
SSD
T
T
T
T
SATD
eK
eTTK, B
e
eTeA .
If we assume reachability of the pair (DA , DB ) and a control law in the form ])[][(])[( 000 nTynTyKTnu d −=
][ 21kkK = , we obtain the closed-loop system shown in Fig. 7.23.
u K -
][ 0nTyd
][][][][])1[(
00000
nTxCnTynTuBnTxATnx
ddd
=+=+
][ 0nTy
Fig. 7.23. Closed-loop system with the feedback gain
The closed-loop system is described by the equation
][][)(])1[( 000 nTKyBnTxKCBATnx dDDDD +−=+ .
Feedback gains for the deadbeat controller are calculated from the equation:
0|))(det( 2,1,0 =−− == iDDD i
KCBAI λλ .
Design method
We can design the deadbeat controller using a simulation method. The following steps are necessary in this case:
1. choose the sampling time 0T ,
2. create the discrete model, 3. calculate feedback gains, 4. simulate the closed-loop discrete system, 5. if the control overruns saturation limits increase the sampling time 0T and repeat
the steps from 1 to 5. EXAMPLE This example shows how to design the deadbeat controller.
Modular Servo System - User’s Manual 56
A goal of the control is to track a reference signal (the angle of the motor shaft). The reference signal is assumed to be a square wave.
Type servo at the MATLAB prompt and then double click the State feedback control discrete button. To design the controller click the Calculate deadbeat controller button. It executes the servo_calc_db.m file where a coefficients of deadbeat controller are calculated according to the algorithm shown above. The body of this file is listed below. Note the comments in the file.
% Continuous linear model of the servo system. % Parameters of the servo are read from workspace A=[0 1;0 -1/Ts]; B=[0; Ks/Ts]; C = [1 0;0 1]; D = zeros( 2, 1 ); % If the distance to the reference signal is big co ntrol value in the % first sample time is big too. Due to we are looki ng for such a T0 % when control does not saturate,we must assume the maximum change of % the reference signal. delta_ref=[25*pi;0]; && it is maximal change of t he reference signal % we start look for T0 T0=0.1; for i = 1:200 T0=T0+0.005; % ** Discrete model for sampling time T0* [Ad,Bd]=c2d(A,B, T0); % Now we calculate a coeffitients of deadbeat contr oller % using the formula : eig(Ad-Bd*K)=0 Z=[Bd(1) Bd(2); Ad(2,2)*Bd(1)-Ad(1,2)*Bd(2) Ad(1, 1)*Bd(2)]; X=[Ad(1,1)+Ad(2,2);Ad(1,1)*Ad(2,2)]; K=(Z\X)'; % Now coefficients of the controller are saved in K % checking if the control saturates in the first s ample time: % u(1)=K*delta_ref;
if abs(K*delta_ref)<=1 K T0 && write K and T0 in Matlab command wi ndow
return end
end The variables K and 0T are stored in the MATLAB workspace after the execution of the
above m-file. In our case for 186=sK [rad/s] and 04.1=sT [s] we obtain
0.0091] 0127.0[=K and 7950.00 =T .
Now double click the State feedback controller buttons to perform the real-time experiment and the model depicted in Fig. 7.24 opens.
Modular Servo System - User’s Manual 57
Fig. 7.24 State feedback controller – a discrete model
This model differs in details from the other models. Due to the fact that the model is discrete, and the sampling time 0T can vary from experiment to experiment 0T is read from
the Matlab workspace. Variable 0T is located in the Simulink model in the following places:
in Fixed step size in tag Solver which is located in Simulation/Simulation Parameters option, in all Zero-Order Hold blocks and in the mask of the Servo device driver. There is no filter connected to the output of the tachogenerator. The filter applied in other models is not discrete one and can not be used here. However it is interesting how the controller works without filtering of the velocity signal.
Set the amplitude of the input signal to 25*pi/2 (as in the previous example), the frequency of the reference signal to 0.05 Hz. Set simulation time equal to 60 [s] and time range in the scope also equal to 60 [s].
Due to the fact that the model includes variables K and 0T and some settings are changed
rebuild it. Click Simulation/Connect to target. Click the Start real-time code option to start the experiment. The results are shown in Fig. 7.25.
Modular Servo System - User’s Manual 58
Fig. 7.25 Results of the position control using the deadbeat controller
Note, that the system does not reach the reference angle in two steps. In fact, the servo is a nonlinear system and it is only approximated by a linear model. Notice, that this control is significant only during two first sampling intervals.
7.4. Optimal design method: LQ controller
The linear-quadratic problem (LQ problem) is a central one in the theory and applications
of optimal control. There are two versions of the LQ problem: the open-loop and the closed-loop optimal control problems. Either the optimal control is given as an explicit function of time for fixed initial conditions, or the optimal controller is synthesised. Further only the second case is considered. The main result of the finite-dimensional linear-quadratic theory is that under suitable assumptions the optimal feedback controller is linear with respect to the state, and constant with respect to time.
The synthesis of the discrete and continuous LQ controller is presented below. For a very
small value of the sampling time the response of the discrete system converges to the response of the corresponding continuous system. The most important question for a designer of a control system, as far as LQ control problem is concerned, is how to select the weighting factors in the cost function.
Modular Servo System - User’s Manual 59
Let us examine separately the continuous and discrete LQ problems.
7.4.1. The continuous case The dynamical model of the DC-motor is described by the linear differential equations:
BuAxx +=&
Cxy = ,
where the matrices A, B and C have the form
=
=
−= 10
01 ,
0 ,1
0
10C
T
KBT
A
S
s
S
. (7.2)
The desired input time history of the state vector is given by )](),([)( 21 tytyty ddd = .
Hence, the error vector e is defined
)()()( tytyte d −= .
A typical quadratic cost function (performance index) has the form
∫ +=kT
TT dttRututQeteuJ0
)]()()()([2
1)( ,
where: • matrix Q ≥ 0, Q is a nonnegative definite matrix, • matrix R > 0, R is a positive definite matrix, • the (A,B) pair is controllable.
The weighting matrices Q and R are selected by a designer but they must satisfy the above conditions. It is most easily accomplished by picking the matrix Q to be diagonal with all diagonal elements positive or zero. Some positive weight (|R|≠0) must be selected for the control, otherwise the solution will include infinite control gains.
The values of elements of Q and R matrices weakly correspond to the performance
specification. A certain amount of trial and error is required with a simulation program to achieve a satisfactory result. A few guidelines can be recommended. For example, if all states are to be kept under close regulation and Q are diagonal with entries so selected that a fixed percentage change of each variable makes an equal contribution to the cost. The matrix R is also diagonal.
If the maximum deviations of the servomechanism outputs are: max1y max2y , and the
maximum deviation of control is maxu , then the cost is:
222
21 2211 Ru)y,Q()y,Q( ++
The coefficients of the Q and R matrices can be set related to the rule:
Modular Servo System - User’s Manual 60
2max1 )(
1)1,1(
yQ = ,
2max2 )(
1)2,2(
yQ = and
2max)(
1
uR =
This rule can be modified to satisfy desired root locations and transient response for selected values of weights. One must avoid saturation effects both of outputs and control.
Due to the differences in methods of analysis, problem formulation and the form of results, we strongly distinguish the linear-quadratic problem with a finite settling time from that with a infinite settling time. However in applications we frequently encounter the situation when the termination moment of the control process is so far away that it does not affect the current control actions. The infinite-time optimal control problem is then posed. The cost function is replaced by the formula:
dttRututQeteuJ TT )]()()()([)(0
+= ∫∞
(7.3)
Then the optimal scalar control *u and the optimal trajectory vector *y are given
)( ** yyKu d −= (7.4)
where K is the feedback matrix. The optimal control problem is now defined as follows: find the gain K such that the
feedback law (7.4) minimises the cost function (7.3) subject to the state equation (7.2). The calculation of the control variable which minimizes the criterion (7.3) is a dynamic optimisation problem. This problem can be solved by variation calculus applying the maximum principle due to the Bellman optimisation principle. The procedure returns the optimal feedback matrix K, the matrix S, the unique positive definite solution to the associated matrix Riccati equation:
SA + ATS - SBR-1BTS + Q = 0
Due to the quadratic appearance of S, there is more than one solution, and S must be positive definite to select the correct one. The procedure returns also the matrix E, the closed-loop roots:
E = eig(A - B*K*C)
The vector K can be calculated by a numeric iterative formula on the basis of the Riccati equation. The associated closed-loop system eBKCAe )( −=& is asymptotically stable.
To solve the LQ controller problem the lqry function from the Control System Toolbox can
be used. The synopsis of lqry is: [K,S,E] = lqry(A,B,C,D,Q,R). In this case the matrix of weights Q relate the outputs y instead of the state x. For the
servomechanism D is the row matrix with two zero elements. The function lqry computes the equivalent Q, R and calls lqr,
The control u is not constrained. This assumption can not be satisfied for a real physical system. One must remember that if the control u saturates then it not satisfies the LQ problem. To return to the LQ problem the amplitude of the u signal should be diminished. In such a case a designer tunes the relative weights between state and control variables. To perform that the simulation tools are recommended.
Modular Servo System - User’s Manual 61
EXAMPLE The goal of the control is to track a reference signal which is defined as a square wave. Set
the amplitude of the reference input signal equal to 25*pi/2. Set the frequency of the reference input to 0.1 Hz and sample time to 0.002 [s].
Type Servo at the MATLAB prompt and then double click the State feedback control
continuous button. To design LQ controller click the Calculate LQ controller button. It executes servo_calc_lq.m file presented below:
% State space representation of servo:
A=[0 1;0 -1/Ts]; B=[0; Ks/Ts]; C = [1 0;0 1]; D = zeros( 2, 1 );
% Set Q and R matrices. These values can be chan ged by a user
Q=[50 0;0 1]; R=1000;
% calculate coefficients of the LQ controller
[K,S,lambda]=lqry(A,B,C,D,Q,R); % type K in Matlab command window
K
For the default values: 186=sK [rad/s] and 04.1=sT [s] we obtain 0.054] 2236.0[=K .
To perform the real-time experiment click the State feedback controller button. When the
model opens (see Fig. 7.26), check parameters of the reference signal. Build the model, click Simulation/connect to target and Start real-time code option to start experiment. The results are given in Fig. 7.27. Notice that the reference signal is reached with accuracy equal to 0.58% and without overshoots. The control signal saturates.
Modular Servo System - User’s Manual 62
Fig. 7.26 Real-time model of the servo with the LQ controller
Fig. 7.27 Results of the position control with a continuous LQ controller
Modular Servo System - User’s Manual 63
7.4.2. The discrete case If we introduce the sampling period 0T then the model can be discretized. The discrete
model of the DC motor has the form:
].[][
][][])1[(
00
000
nTxCnTy
nTuBnTxATnx
D
DD
=
+=+ (7.5)
where the matrices: DA , DB and DC are in the form
−
−−=
−==
−
−
−
−
)1(
))1((
0
)1(10
0
0
0
0 0
s
s
s
s
T
T
S
T
T
SSD
T
T
T
T
SATD
eK
eTTK, B
e
eTeA .
The matrix DA is the fundamental solution of the differential equation (7.5) calculated for
the sampling period 0T . The explicit values of the matrices DA and DB of the servo system
can be obtained numerically by the use of c2d function. C2d converts a continuous state representation to the discrete corresponding to the continuous. The procedure is a part of Control System Toolbox. One must simply type the command:
[ DA , DB ]=c2d(A,B, T0) The optimal feedback law:
][][ ],[][ 0000 nTyynTenTKenTu d −==
minimizes the cost function:
∑=
+=N
n
TT nRununenQneuJ0
)]()()()()([)( (7.6)
subject to the state equation (7.5). The dlqry function from the Control System Toolbox is used to solve the discrete-time linear-quadratic control problem. The synopsis of the dlqry and lqry programs are identical. The dlqr also solves and returns matrix S, the unique positive definite solution to the associated discrete iterative matrix Riccati equation:
QASBBSBRBSAASAS Di
TDDi
TDDi
TDDi
TDi ++−= −
+1
1 )( .
The feedback matrix is derived from S by D
TDD
TD SABSBBRK 1)( −+=
Modular Servo System - User’s Manual 64
EXAMPLE A goal of the control is the same as in the continuous case example. Assume that sampling
time for discrete system 1.00 =T [s].
In Servo Control Window double click the State feedback control discrete button. To
design the LQ controller click the Calculate LQ controller button. It executes the servo_calc_lq_d.m file presented below.
% State space representation of servo: A=[0 1;0 -1/Ts]; B=[0; Ks/Ts]; C = [1 0;0 1]; D = zeros( 2, 1 ); % set sampling time T0=0.1; % calculate discrete model from continuous [Ad,Bd]=c2d(A,B, T0) % set Q and R matrices Q=[50 0;0 1]; R=1000; % design discrete LQ controller [K,S,lambda]=dlqry(Ad,Bd,C,D,Q,R); K
For the default values: 186=sK [rad/s] and 04.1=sT [s] we obtain 0.0395] 139.0[=K .
To perform the real-time experiment click the State feedback controller button and the
model shown in Fig. 7.24 opens. It is the same model as was previously applied to the deadbeat control. Set the frequency of the reference signal to 0.1 [Hz] the simulation time to 30 [s] and the time range of the scope to 30 [s]. These settings correspond to the values which have been assumed for the continuous LQ controller. Build model, click the Simulation/connect to target and the Start real-time code options to start experiment.
The results are shown in Fig. 7.27. They are similar to these for the continuous controller. The reference signal is reached with accuracy equal to 1% and without overshoots. The control signal saturates as in the previous example.
Modular Servo System - User’s Manual 65
Fig. 7.28 Results of the position control by the discrete LQ controller
Modular Servo System - User’s Manual 66
8. Description of the Modular Servo class properties The CServo is a MATLAB class, which gives the access to all the features of the RT-
DAC/PCI board equipped with the logic for the MSS model. The RT-DAC/PCI board is an interface between the control software executed by a PC computer and the power-interface electronic of the modular servo model. The logic on the board contains the following blocks:
• incremental encoder registers – two 24-bit registers to measure the position of the incremental encoders. There are two identical encoder inputs, that may be applied to measure the shaft positions of two modular servo blocks;
• incremental encoder reset logic. The incremental encoders generate different output waves when the encoder rotates clockwise and counter-clockwise. The encoders are not able to detect the reference (“zero”) position. To determine the “zero” position the incremental encoder registers have to be set to zero by the computer program;
• PWM generation block – generates the Pulse-Width Modulation output signal. Simultaneously the direction signal and the brake signal are generated to control the power interface module. The PWM prescaler determines the frequency of the PWM wave,
• power interface thermal flags –the thermal flags can be used to disable the operation of the overheated power amplifier,
• interface to the on-board analog-to-digital converter. The A/D converter is applied to measure the position of the external potentiometer and to measure the output voltage of the tachogenerator.
All the parameters and measured variables from the RT-DAC/PCI board are accessible by
appropriate properties of the CServo class. In the MATLAB environment the object of the CServo class is created by the command: object_name = CServo; The get method is called to read a value of the property of the object: property_value = get( object_name, ‘property_name’ ); The set method is called to set new value of the given property: set( object_name, ‘property_name’, new_property_value ); The display method is applied to display the property values when the object_name is entered in the MATLAB command window. This section describes all the properties of the CServo class. The description consists of the
following fields:
Purpose Provides short description of the property Synopsis Shows the format of the method calls Description Describes what the property does and the restrictions
subjected to the property Arguments Describes arguments of the set method See Refers to other related properties Examples Provides examples how the property can be used
Modular Servo System - User’s Manual 67
8.1. BaseAddress
Purpose: Read the base address of the RT-DAC/PCI board.
Synopsis: BaseAddress = get( sv, ‘BaseAddress’ );
Description: The base address of RT-DAC/PCI board is determined by computer. Each CServo object has to know the base address of the board. When a CServo object is created the base address is detected automatically. The detection procedure detects the base address of the first RT-DAC/PCI board plugged into the PCI slots.
Example: Create the CServo object: sv = CServo; Display their properties by typing the command: sv
Type: CSERVO Object BaseAddress: 54272 / D400 Hex Bitstream ver.: x402 Encoder: [ 0 46606 ][bit] Reset Encoder: [ 0 0 ] Input voltage: [ 0.1123 0.1123 ][V] PWM: [ 0 ] PWM Prescaler: [ 0 ] Thermal status: [ 0 ] Thermal flag: [ 1 ] Angle: [ 0 71.4927 ][rad] Time: 31.657 [sec]
Read the base address: BA = get( sv, ‘BaseAddress’ );
8.2. BitstreamVersion
Purpose: Read the version of the logic stored in the RT-DAC/PCI board.
Synopsis: Version = get( sv, ‘BitstreamVersion’ );
Description: The property determines the version of the logic design of the RT-DAC/PCI board. The modular servo models may vary and the detection of the logic design version makes it possible to check if the logic design is compatible with the physical model.
8.3. Encoder
Purpose: Read the incremental encoder registers.
Modular Servo System - User’s Manual 68
Synopsis: enc = get( sv, ‘Encoder’ ); Description: The property returns two digits. They are equal to the number of impulses
generated by the corresponding encoders. The encoder counters are 24-bit numbers so the values of this property is from (–224) to (224-1). When an encoder counter is reset the value is set to zero.
The incremental encoders generate 4096 pulses per rotation. The values of the Encoder property should be converted into physical units.
See: ResetEncoder, Angle, AngleScaleCoeff
8.4. Angle
Purpose: Read the angle of the encoders. Synopsis: angle_rad = get( sv, ‘Angle’ ); Description: The property returns two angles of the corresponding encoders. To calculate
the angle the encoder counters are multiplied by the values defined as the AngleScaleCoeff property. The angles are expressed in radians.
See: Encoder, AngleScaleCoeff
8.5. AngleScaleCoeff
Purpose: Read the coefficients applied to convert the encoder counter values into
physical units. Synopsis: scale_coeff = get( sv, ‘AngleScaleCoeff’ ); Description: The property returns two digits. They are equal to the coefficients applied to
convert encoder impulses into radians. The incremental encoders generate 4096 pulses per rotation so the coefficients are equal to 2*pi/4096.
See: Encoder, Angle
8.6. PWM
Purpose: Set the direction and duty cycle of the PWM wave. Synopsis: PWM = get( sv, ‘PWM’ ); set( sv, ‘PWM’, NewPWM );
Modular Servo System - User’s Manual 69
Description: The property determines the duty cycle and direction of the PWM wave. The PWM wave and the direction signals are used to control the DC drive so in fact this property is responsible for the DC motor control signal. The NewPWM variable is a scalars in the range from –1 to 1. The value of –1, 0.0 and +1 mean respectively: the maximum control in a given direction, zero control and the maximum control in the opposite direction to that defined by –1. The PWM wave is not generated if the thermal flag is set and the power amplifier is overheated.
See: PWMPrescaler, Therm, ThermFlag Example: set( sv, ‘PWM’, [ -0.3 ] );
8.7. PWMPrescaler
Purpose: Determine the frequency of the PWM wave. Synopsis: Prescaler = get( sv, ‘PWMPrescaler’ ); set( sv, ‘PWMPrescaler’, NewPrescaler ); Description: The prescaler value can vary from 0 to 63. The 0 value generates the
maximal PWM frequency. The value 63 generates the minimal frequency. The frequency of the generated PWM wave is given by the formula:
PWMfrequency = 40MHz / 1023 / (Prescaler+1)
See: PWM
8.8. Stop
Purpose: Sets the control signal to zero. Synopsis: set( sv, ‘Stop’ ); Description: This property can be called only by the set method. It sets the zero control of
the DC motor and is equivalent to the set(sv, ‘PWM’, 0) call. See: PWM
8.9. ResetEncoder
Purpose: Reset the encoder counters. Synopsis: set( sv, ‘ResetEncoder’, ResetFlags );
Modular Servo System - User’s Manual 70
Description: The property is used to reset the encoder registers. The ResetFlags is a 1x2
vector. Each element of this vector is responsible for one encoder register. If the element is equal to 1 the appropriate register is set to zero. If the element is equal to 0 the appropriate register counts encoder impulses.
See: Encoder Example: To reset only the first encoder register execute the command: set( sv, ‘ResetEncoder’, [ 1 0 ] );
8.10. Voltage
Purpose: Read two voltage values. Synopsis: Volt = get( sv, ‘Voltage’ ); Description: Returns the voltage of two analog inputs. Usually the analog inputs are
applied to measure the position of the external potentiometer and the output of the tachogenerator.
8.11. Therm
Purpose: Read thermal status flag of the power amplifier. Synopsis: Therm = get( sv, ‘Therm’ ); Description: Returns the thermal flag of the power amplifier. When the temperature of a
power amplifier is too high the flag is set to 1. See: ThermFlag
8.12. ThermFlag
Purpose: Control an automatic power down of the power amplifiers. Synopsis: ThermFlag = get( sv, ‘ThermFlag’ ); set( sv, ‘ThermFlag’, NewThermFlag ); Description: If the ThermFlag and NewThermFlag are both equal to 1 the DC motor is
not excited by the PWM wave when the power interface is overheated. See: Therm
Modular Servo System - User’s Manual 71
8.13. Time
Purpose: Return time information. Synopsis: T = get( sv, ‘Time’ ); Description: The CServo object contains the time counter. When a CServo object is
created the time counter is set to zero. Each reference to the Time property updates its value. The value is equal to the number of milliseconds which elapsed since the object was created.
8.14. Quick reference table
Property name Operation* Description
BaseAddress R Read the base address of the RT-DAC/PCI board
BitstreamVersion R Read the version of the logic design for the RT-DAC/PCI board
Encoder R Read the incremental encoder registers
Angle R Read the angles of the encoders
AngleScaleCoeff R Read the coefficient applied to convert encoder positions into radians
PWM R+S Read/set the parameters of the PWM waves
PWMPrescaler R+S Read/set the frequency of the PWM waves
Stop S Set the control signal to zero
ResetEncoder R+S Reset the encoder counters or read the reset flags
Voltage R Read the input voltages
Therm R Read the thermal flags of the power amplifiers
ThermFlag R+S Read/set the automatic power down flag of the power amplifier
Time R Read time information
• R – read-only property, S – allowed only set operation, R+S –property may be read and set
8.15. CServo Example
To familiarise a reader with the CServo class this section presents an M-file example that uses the properties of the CServo class to measure the static characteristics of the DC
Modular Servo System - User’s Manual 72
motor (see section 6). The static characteristics is a diagram showing the relation between DC motor control signal and the motor shaft velocity. The M-file changes the control signal and waits until the MSS reaches steady-state. The velocity of the shaft is obtained in two ways: • the M-file measures the output voltage from the tachogenerator, • the M-file measures the encoder position in two time points and calculates the
velocity as the difference of positions divided by the time period between the time points.
The M-file is written in the M-function form. The name of the M-function is Servo_PWM2RPM.
The function requires two parameters:
• CtrlDirection - a string that selects how to change the control value. The 'A' string causes the control is changed in ascending manner (from -1 to 1), the 'D' string causes the control is changed in descending order (from 1 to -1) and the 'R' string causes reverse double changes (from -1 to +1 and after that from +1 to -1),
• MinControl, MaxControl – minimal and maximal control signal values. The control signal changes within the region defined by these values,
• NoOfPoints - number of characteristics points within the MinControl/MaxControl range. The exact number of points of the characteristics declared by this parameter is enlarged to two points namely: MinControl and MaxControl.
The body of this function is given below. The comments within the function describe the main stages. function ChStat = Servo_PWM2RPM( … CtrlDirection, MinControl, MaxCon trol, NoOfPoints ) CtrlDirection = lower( CtrlDirection ); NoOfPoints = max( 1, NoOfPoints+1 ); % Calculate control step Step = (MaxControl-MinControl) / NoOfPoints; switch CtrlDirection case 'a' Ctrl = MinControl:Step:MaxControl; case 'd' Ctrl = MaxControl:-Step:MinControl; case 'r' Ctrl = [ MinControl:Step:MaxControl MaxControl: -Step:MinControl]; otherwise % This should not happen error('The CtrlDirection must be ''A'',''D'' or ''R''.') end FigNum = figure( 'Visible', 'on', ... 'NumberTitle', 'off', ... 'Name', 'Velocity vs. PWM characteris tic', ... 'Menubar', 'none' ); sv = cservo; Control = []; VelEnc = []; % Optionally set the PWM prescaler %set( sv, 'pwmprescaler', 20);
Modular Servo System - User’s Manual 73
for i=1:length(Ctrl) % Set a new control value set( sv, 'PWM', Ctrl(i) ); % Reset encoders set( sv, 'ResetEncoder', [1 1] ); set( sv, 'ResetEncoder', [0 0] ); pause( 5 ) AuxEnc = get( sv, 'Encoder' ); TimeBeg=gettime; pause( 2 ) % Calculate velocity based on the encoder positio ns VelEnc(i,:) = 2*pi*(get( sv, 'Encoder' )-AuxEnc)/ … 4096/((gettime-TimeBeg)/1000); % [r ad/s] Control(i) = get( sv, 'PWM' ); Volt(i,:) = get( sv, 'Voltage' ); % Perform 10000 A/D conversions and calculate ave rage values AuxVolt = [0 0]; for j=1:10000 AuxVolt = AuxVolt + get( sv, 'Voltage' ); end Volt(i,:) = AuxVolt/10000; % Convert voltage into velocity Volt2Vel = 20.4*Volt(:,2); % Plot data subplot(211); plot( Control, VelEnc(:,2), Control, VelEnc(:,2), 'x' ); grid title( 'Encoder velocity vs. PWM' ); xlabel('PWM control value'); ylabel( 'Velocity [r ad/s]' ); subplot(212); plot( Control, Volt2Vel, Control, Volt2Vel, 'x' ) ; grid title( 'Tacho velocity vs. PWM' ); xlabel('PWM control value'); ylabel( 'Tacho veloc ity [rad/s]' ); end % Assign data to the structure returned by the func tion ChStat.Control = Control; ChStat.TachoVelocity = VelEnc(:,2); ChStat.EncoderVelocity = Volt2Vel; % Switch off the control set( sv, 'Stop');
The diagrams generated by the call servo_pwm2rpm('r',-0.5,0.5,19), are shown below. The diagrams present the velocity of the shaft as function of the control signal. The control signal changes from –0.5 to +0.5. The velocity value is obtained in two ways. At the upper diagram the velocity is calculated from the encoder positions. The lower diagram presents the velocity obtained from the tachogenerator.
Modular Servo System - User’s Manual 74
Fig. 8.1 Result of the servo_pwm2rpm function call
The values on the diagram may vary from an experiment to an experiment as they depend
on the configuration of the modular servo set-up.
Modular Servo System - User’s Manual 75
9. Some technical data
20 Φ
15
68
66 Φ
20 Φ25 Φ
5
5
66 Φ
5,8
Brass inertia load 2.030 kg 0.055 kg Aluminium wheels 0.05 kg
Fig. 9.1 Dimensions and weights of the MSS mechanical elements
Data sheet of the DC motor is available at http://www.buehlermotor.com/cgi-bin/sr.exe/productpageus&productpage=54 The gearbox ratio 25=N