Module 1 Installation and configuration of Speednet 3.1.1 in SPC 1.1.1
Transcript
Page 1: Module 1 Installation and configuration of Speednet 3.1.1 in SPC 1.1.1.

Module 1Installation and configuration of Speednet 3.1.1 in SPC

1.1.1

Page 2: Module 1 Installation and configuration of Speednet 3.1.1 in SPC 1.1.1.

Module objective

At the end of the module, you will be able to• Recognize the components of Speednet• Install Speednet communication,• Install server and client components• Configure Speednet for SPC• Configure communication module of

Speednet for successful data transfer

1.1.2

Page 3: Module 1 Installation and configuration of Speednet 3.1.1 in SPC 1.1.1.

1.1.3

Page 1

The Speednet network

Speednet in SPC

Speednet Central server

1. Uploads collected and despatched articles data and bags2. Receives data of bags and articles for delivery; Updates delivery info

Point of sale of SPC

Point of sale of linked office

Non computerised counters

BNPL customers

Nodal delivery offices with speednet

Linked offices without speednet

Booked data updation

Bag transfer

Articles for delivery with list

Downloads bag data and uploads delivery data

Page 4: Module 1 Installation and configuration of Speednet 3.1.1 in SPC 1.1.1.

Components explained

1.1.4

• Resides in one of the client systems with internet connection; Interchanges article and bag data with central server

• Should never be installed on the Server

Speednet Communication client

• Installed on the server and the server folder shared; Accessed by the Speednet client while software is running

Speednet Server

• Accessed by users (Supervisors and operators) to perform routine operations; Installed in all the clients

Speednet client

Page 5: Module 1 Installation and configuration of Speednet 3.1.1 in SPC 1.1.1.

Installation modes

• Client/server mode– Server component installed in server– Client component resides in client systems– Communication module installed in one of the

client systems• Standalone mode

– In offices with single system, both client and server component as well as Communication module are installed in the same system

1.1.5

Page 6: Module 1 Installation and configuration of Speednet 3.1.1 in SPC 1.1.1.

Installation process

Communication module installed in a client system and EMS client folder shared with appropriate access rights

Server component installed on the server; Speednet Server folder created is shared with suitable access permissions for all users in the domain

Client component initially installed in server and connected to server component; Database is created and application is configured; Later installed in all clients

1.1.6

Page 7: Module 1 Installation and configuration of Speednet 3.1.1 in SPC 1.1.1.

Prerequisites

1. Windows client/server network comprising the followinga. Windows 2000/2003/2008 server with dot net framework

2.0 or later, on the serverb. Windows 2000 Professional/xp/vista/7 in clients with dot net

framework 2.0 or laterc. A domain binding the network to implement centralized

securityd. Internet connection in the communication cliente. A standard antivirus system to protect the communication

client (compulsory) and all other client systems(optional), with an active registration and auto-updation and on-access protection enabled

1.1.7

Page 8: Module 1 Installation and configuration of Speednet 3.1.1 in SPC 1.1.1.

Pre-requisites (cont’d)

2. SQL Server 2000/2005/2008 standard edition installed on the server and mixed authentication enabled with a secure SA password

3. Latest service packs available - Service pack 4 for SQL 2000/ service pack 2 for SQL 2005 (minimum requirement)

4. Client edition of SQL Server in client systems with no management tools

5. A domain user account created for each user in the office

1.1.8

Page 9: Module 1 Installation and configuration of Speednet 3.1.1 in SPC 1.1.1.

Installation steps – Communication component

Place the setup CD in the CD/DVD drive in the server or local system

Open the CD and run the communication setup

Follow the setup as in the screenshots shown in the next slide

On completion of installation share EMS client folder with appropriate permissions

1.1.9

Page 10: Module 1 Installation and configuration of Speednet 3.1.1 in SPC 1.1.1.

Communication component installation process - 1

• When you run the setup, this is the first dialog box that comes up

• Click the right arrow button to continue setup

1.1.10

Page 11: Module 1 Installation and configuration of Speednet 3.1.1 in SPC 1.1.1.

Communication component installation process - 2

• This is the next step

• Here you have the option to change the destination folder using Change Directory button; The default path is C:\EMSClient

• Follow the onscreen inst

1.1.11

Page 12: Module 1 Installation and configuration of Speednet 3.1.1 in SPC 1.1.1.

Communication component installation process - 3

• Setup will now show you the program group under which the application will be available for access

• Click Continue to proceed

1.1.12

Page 13: Module 1 Installation and configuration of Speednet 3.1.1 in SPC 1.1.1.

Communication component installation process (final step)

• In this step you should select where the module is installed– In offices with Speednet,

select the default option SpeedNet

– In offices with Point of sale only (extension counters) having internet facility use Point of Sale option (to upload booked data)

• This completes the setup

1.1.13

Page 14: Module 1 Installation and configuration of Speednet 3.1.1 in SPC 1.1.1.

Watch the demo of communication component installation in faculty system

1.1.14

Page 15: Module 1 Installation and configuration of Speednet 3.1.1 in SPC 1.1.1.

Exercise 1.1.1 – Installation of Speednet communication

1.1.15

Page 16: Module 1 Installation and configuration of Speednet 3.1.1 in SPC 1.1.1.

Server component installation

Install the server component in the server in a drive

other than C drive (preferably)

Depending on the office status select the components

like BNPL, collection agent

Set up steps are as in the sequence in

next slide

On completion of installation, share

the server component

1.1.16

Page 17: Module 1 Installation and configuration of Speednet 3.1.1 in SPC 1.1.1.

Server setup sequence – 1

• Access the Speednet server component in the setup CD and launch the setup

• As with the communication module, click the right arrow button in this initial window to continue setup

1.1.17

Page 18: Module 1 Installation and configuration of Speednet 3.1.1 in SPC 1.1.1.

Server Setup sequence - 2

• In this dialog box, you are prompted to change the installation path with a default path shown

• Change the installation path to a drive other than C to ensure hassle free growth and security

• Click the setup icon to continue

1.1.18

Page 19: Module 1 Installation and configuration of Speednet 3.1.1 in SPC 1.1.1.

Server Setup sequence - 3

• In this final step, choose whether your office is– Delivery office– Handles BNPL and

collection agent articles

• Install flush data, as per requirements

• Click OK to finish setup• Share the SpeednetServer

folder in the installation path

1.1.19

Page 20: Module 1 Installation and configuration of Speednet 3.1.1 in SPC 1.1.1.

Exercise 1.1.2 – Installation of server component

1.1.20

Page 21: Module 1 Installation and configuration of Speednet 3.1.1 in SPC 1.1.1.

Client setup process

Install the client component now on the server and connect to the server component

The steps involved is shown in the next slide

Watch the demo of installation process

1.1.21

Page 22: Module 1 Installation and configuration of Speednet 3.1.1 in SPC 1.1.1.

Client setup sequence - 1

• In this initial setup dialog box, click the setup icon to proceed with setup

1.1.22

Page 23: Module 1 Installation and configuration of Speednet 3.1.1 in SPC 1.1.1.

Client setup sequence - 2

• In this dialog box, the program group in which the application will be available gets displayed, click Continue to proceed

1.1.23

Page 24: Module 1 Installation and configuration of Speednet 3.1.1 in SPC 1.1.1.

Client setup sequence - 3

• The message box Path/file access error that appears is a non critical error; Click Retry and the next dialog box appears

• In this dialog box, you should browse and point to the Speednet Server

1.1.24

Page 25: Module 1 Installation and configuration of Speednet 3.1.1 in SPC 1.1.1.

Client setup sequence - 4

• Now click OK to complete the client setup

1.1.25

Page 26: Module 1 Installation and configuration of Speednet 3.1.1 in SPC 1.1.1.

Exercise 1.1.3 – Speednet client setup

1.1.26

Page 27: Module 1 Installation and configuration of Speednet 3.1.1 in SPC 1.1.1.

Configuration for SPC

• Run the speednet on completion of installation to complete the following tasks; The application will lead you through these tasks in sequence– Creating database– Customizing the application for SPC– Creating users– Connecting to Point of sale and communication

components– Creating other environments like connected offices,

despatch and receipt schedules and delivery• The sequence is shown in the next slide

1.1.27

Page 28: Module 1 Installation and configuration of Speednet 3.1.1 in SPC 1.1.1.

Configuration step - 1

– In this dialog box, we create the supervisor

1.1.28

Page 29: Module 1 Installation and configuration of Speednet 3.1.1 in SPC 1.1.1.

Configuration step - 2

• In this dialog box we localize the application to the office concerned

• The office can be either a SPCC or a linked office

• If you select linked office configuration, you should search for your office from the attached SPCC list

1.1.29

Page 30: Module 1 Installation and configuration of Speednet 3.1.1 in SPC 1.1.1.

Configuration step - 3

• Using this dialog box, you should connect the speednet to the Point of sale existing in the same network – to fetch booked article data

• Select whether POS is installed, if so how

• If POS is in the same network enter the name of the server

1.1.30

Page 31: Module 1 Installation and configuration of Speednet 3.1.1 in SPC 1.1.1.

Configuration step - 4

• In this step, you should select the system and shared folder (EMS Client) where Communication module is installed

• Use the Browse button to search and point to the EMS Client in the network and proceed further

1.1.31

Page 32: Module 1 Installation and configuration of Speednet 3.1.1 in SPC 1.1.1.

Configuration step - 5

• In this step, if you click View offices you will get list of SPCCs, linked offices and RMS/TMOs

• You cannot add any new SPC or linked office

• You can however add any other office to which bags can be closed in your SPC is regularly closing such bags

1.1.32

Page 33: Module 1 Installation and configuration of Speednet 3.1.1 in SPC 1.1.1.

Configuration step - 6

• The User Management dialog box that appears is used to create operators in the system

• Click the User Management button to complete this task

1.1.33

Page 34: Module 1 Installation and configuration of Speednet 3.1.1 in SPC 1.1.1.

Configuration step - 7

• In this dialog box, we define the set numbers if the office works on more than one shift

• If no shift system is in vogue, simply check off the check box and proceed next

1.1.34

Page 35: Module 1 Installation and configuration of Speednet 3.1.1 in SPC 1.1.1.

Configuration step - 8

• This dialog box is used to configure the designations

• Duties are assigned to designations

• Users are mapped to designations every day at the time of job allocation

• Click Designations button and create the number of required designations

1.1.35

Page 36: Module 1 Installation and configuration of Speednet 3.1.1 in SPC 1.1.1.

Configuration step - 9

• Here we configure the despatch schedules of the SPC

• Ascertain the carrier, set, days of despatch and destination from the office and create the schedules

1.1.36

Page 37: Module 1 Installation and configuration of Speednet 3.1.1 in SPC 1.1.1.

Configuration step - 10

• In this step, we configure the receipt schedules for the office

• Ascertain the existing receipt pattern and configure the schedule similarly as despatch schedule

1.1.37

Page 38: Module 1 Installation and configuration of Speednet 3.1.1 in SPC 1.1.1.

Configuration step - 11

• Here you need to furnish Delivery environment information

• Ascertain the existing environment from the SPC and enter these data

• You need to also enter the names of postmen and bulk addressees, if the delivery environment exists

1.1.38

Page 39: Module 1 Installation and configuration of Speednet 3.1.1 in SPC 1.1.1.

Configuration step - Final

• You now move to this concluding step

• Click Finish to complete the configuration

1.1.39

Page 40: Module 1 Installation and configuration of Speednet 3.1.1 in SPC 1.1.1.

Demo of initial configuration in faculty system

1.1.40

Page 41: Module 1 Installation and configuration of Speednet 3.1.1 in SPC 1.1.1.

Exercise 1.1.4 – Initial configuration

1.1.41

Page 42: Module 1 Installation and configuration of Speednet 3.1.1 in SPC 1.1.1.

Further configuration

• BNPL distance configuration (local and non configured locations)

• Duty allocation for designations

• BNPL customer creation and related configuration

When application is run the first time, these customizations are required further

1.1.42

Page 43: Module 1 Installation and configuration of Speednet 3.1.1 in SPC 1.1.1.

43

Local settings• When Speednet is run for first time

distance related configuration needs to be completed

• In this dialog box you get a list of offices for which aerial distance could not be auto-configured (includes local offices)

• You are given option to configure the above offices

• Calculate the distance for each office connecting them to SPC concerned and select appropriate distance slab

• For linked offices, initially select the distance as in the range of 1-200; Later, you can modify the local offices

Page 44: Module 1 Installation and configuration of Speednet 3.1.1 in SPC 1.1.1.

Local settings cont’d

• Login as supervisor in Speednet to proceed with localising

• First create data of existing BNPL customers getting data from SPC

• Configure Miscellaneous charges – Discount, Service tax etc.,

1.1.44

Page 45: Module 1 Installation and configuration of Speednet 3.1.1 in SPC 1.1.1.

45

Local settings cont’d

• Working as supervisor perform duty allocation to designations created based on the need of the office

• Use the menu Master – Duty allocation

Page 46: Module 1 Installation and configuration of Speednet 3.1.1 in SPC 1.1.1.

BNPL OB configuration

Special attention be given to this: Checking the box and closing the window prevents attempts to manipulate balances – menu itself disappears

1.1.46

Page 47: Module 1 Installation and configuration of Speednet 3.1.1 in SPC 1.1.1.

Exercise 1.1.5 – Localisation of Speednet

1.1.47

Page 48: Module 1 Installation and configuration of Speednet 3.1.1 in SPC 1.1.1.

Configuring communication module

• Involves– Connection to Speednet server component– Setting the internet connection mode– Configuring the time lag between server calling

attempts • The following set of slides depict the sequence

1.1.48

Page 49: Module 1 Installation and configuration of Speednet 3.1.1 in SPC 1.1.1.

Communication client configuration setup 1

• Run the speednet communication

• Click the Yes button in the message box to launch the configuration process

1.1.49

Page 50: Module 1 Installation and configuration of Speednet 3.1.1 in SPC 1.1.1.

Communication client config step 2

• In this step first configure the mode of internet connection

• Click the server path and browse and point to the speednet server component

1.1.50

Page 51: Module 1 Installation and configuration of Speednet 3.1.1 in SPC 1.1.1.

Communication client config step 3

• In this step configure the time lag between two attempts to connect to server in case of errors

1.1.51

Page 52: Module 1 Installation and configuration of Speednet 3.1.1 in SPC 1.1.1.

Exercise 1.1.6 – Configuring Speednet communication

1.1.52

Page 53: Module 1 Installation and configuration of Speednet 3.1.1 in SPC 1.1.1.

Module 1 ends

This completes the installation and configuration of Speednet

1.1.53


Recommended