RFE1 SurveyRFE1 SurveyRFE1 SurveyRFE1 Survey
• RFE stands for Ready for Electronics.
• RFE1 survey is done to check the site environment and infra readiness before carrying the installation of the system or network element .
• It’s a first step of deployment project in which we check all parameters
RFE1 Survey- Definition
2013 © Samsung Electronics 2
• It’s a first step of deployment project in which we check all parameters those are required for eNB installation like measuring lengths of cables, checking the grounding, power, space availability for network element.
• Cable Lengths: – Short cable can delay the installation or if too long can affect the project cost &
quality.
• Site Infra: – Site Infra should be as per site requirement, if not, it affects the project timeline.
• To reconfirm the RF planning’s requirement and the data in TSSR
Need for RFE1 Survey!
2013 © Samsung Electronics 3
(Technical Site Survey Report).
• Note– P1 sites are the sites built and owned by RJIL, also called as ‘own’ sites. – RP1 sites are the sites that will be built by Rcom and also called as ‘Shared or Co-
Lo’.
RFE1 Work Flowchart
Start
Site Allotment with site detail
& TSSR Report as applicable
Key collection from KCC
RFE 1 Survey with proper
Tools
2013 © Samsung Electronics 4
Tools
Submit the RFE1 report to
Samsung eNB Engg. & upload
in GIS within 24Hrs
Any
Issue
Yes
No
End
Pre RFE1 Status
Summary of Pre RFE1:The pre RFE1 covers status of civil work, electricity board (EB) availability and utility commissioned.
2013 © Samsung Electronics 5
Before going to the site, the engineer needs to make sure about the following important points:
– Route Plan• Address• Transportation
– Access Feasibility
Pre-requisites for RFE1
2013 © Samsung Electronics 6
• Company letter • I Card• Training I Card
– Tools– Required Documentation
• RFE1 site survey form• TSSR form (only for P1/own site)• IFC diagram (only for P1/own site)
RFE1 Survey RFE1 Survey RFE1 Survey RFE1 Survey Tools Tools Tools Tools ListListListList
The basic tools for RFI Survey are listed in the table below. • Helmet• Safety/Harness Belt (with two hooks)• Safety Shoes• Permanent Pen (Black)• Compass with mirror• GPS• Laser Meter
RFE1 Survey Tools List
2013 © Samsung Electronics 9
• Laser Meter• Digital Camera• Measuring Tape• Tilt Meter• Ruler Scale• Multimeter• Ladder• Torch
9
RFE1 Survey Tools Description
Basic RFI Survey Tools
No. Name Specification Picture Purpose Make Suggested
1 Helmet Common Basic Safety Equipment PETER ISI
2 Safety/Harness belt50 x 2.0 x 1200mm,
W/Simple buckleBasic Safety Equipment PETER ISI
2013 © Samsung Electronics 10
W/Simple buckle
3 Safety shoes Basic Safety Equipment Standard
4Permanent Pen
(Black)
Should be marked
"Permanent" on the
pen
(Back Color)
To mark the site ID,
Name on the name
plate, etc..
(Not to erase
permanently)
Any Standard
RFE1 Survey Tools Description
Basic RFI Survey Tools
No. Name Specification Picture Purpose Make Suggested
5Compass with
MirrorCommon
To check the
Azimuth
6 GPS Tracking systemTo locate the exact
locationTrex/Garmin
2013 © Samsung Electronics 11
location
7 Laser Meter
Should be able to
calculate distance
till 50m
To calculate
distanceStandard
8
Digital Camera
with data Cable
or memory card
reader
over the 10 Mega
pixels,
10x zoom
Take a picture
of TowerSamsung
RFE1 Survey Tools Description
Basic RFI Survey Tools
No. Name Specification Picture Purpose Make Suggested
9
Tape Measure-
Cloth-50m
Metal-5m
5 m/50 m Basic Tool Any Standard
10 Tilt Meter To Measure Tilt Any Standard
2013 © Samsung Electronics 12
11 Ruler Scale 30cmTo calculate Pole
DiameterCamlin/Faber Castle
12 Ladder 3Mts
To access the
RTP/GBM to around
3m.
Any Standard
13 Multimeter
DC,AC
measurement
1.0~60 kgf.cm
To measure DC, AC
PowerMastec
RFE1RFE1RFE1RFE1----Survey ReportSurvey ReportSurvey ReportSurvey Report
RFE1 Survey Form
Microsoft Office
2013 © Samsung Electronics 14
Microsoft Office
Excel Worksheet
RFE1 Survey Attributes to be Checked Carefully
Sr. No. Description
1 Pole Bending
2 Non availability of Outdoor Grounding Bar.
3Non availability of Internal Grounding Bar
with 3 holes free
4Non availability of Cable tray till
ODC (Roxtec and/ or Cable Inlet)
5Non availability of Ladder to access the
2013 © Samsung Electronics 2222
5ODC & Tower
6 Water Seepage in ODC
7 Non Availability of EB/SEB Supply Availability
8 Non Availability of Battery Bank
9 Non availability MCB-10A/25A
10 Lightning Arrestor covers the whole tower from top
11 RF Antenna Pole Position Not as per the TSSR
Check List CSRCheck List CSRCheck List CSRCheck List CSR
CSRCSRCSRCSR----ChecklistChecklistChecklistChecklist
Microsoft Office Microsoft Office
Excel Worksheet
Tower Tower Tower Tower Detail Detail Detail Detail SnapsSnapsSnapsSnaps
READY FOR ELECTRONICS1 SURVEY FORM
2013 © Samsung Electronics 26
READY FOR ELECTRONICS1 SURVEY FORM
2013 © Samsung Electronics 27
READY FOR ELECTRONICS1 SURVEY FORM
2013 © Samsung Electronics 28
READY FOR ELECTRONICS1 SURVEY FORM
2013 © Samsung Electronics 29
Obstruction FormObstruction FormObstruction FormObstruction Form
READY FOR ELECTRONICS1 SURVEY FORMREADY FOR ELECTRONICS1 SURVEY FORM
On to be filled if survey engineer finds any obstruction
Circle :- Delhi
Site Name / IP Site Name ABC
Site ID / IP Site ID 123
Contact Person Address & Contact No.
0
10 m
15 m
5 m
Obstruction should be checked at Antenna Height
2013 © Samsung Electronics 31
Remarks (if any)
The distance from obstruction to be calculated with laser gun (for EMF analysis)
Azimuth (˚) Distance (m) Obstacle Ht. (m) - AGL Description
Alpha
Beta
Gamma
270
180
900 m
5 m
GBM LayoutGBM LayoutGBM LayoutGBM Layout
READY FOR ELECTRONICS1 SURVEY FORM
Entry to
top of tower
READY FOR ELECTRONICS1 SURVEY FORM
Circle :- Delhi Site Name / IP Site Name :- ABC Site ID / IP Site ID :- 123
Drawing should be with respect to North N=0°
2013 © Samsung Electronics 33
Samsung DU
in Rack
GBM
Samsung Antenna & RRH
SamsungAntenna & RRH
Samsung Antenna & RRH
Sec 3: 210 deg
at 20mSec 2: 100 deg
at 20m
Sec 1: 0 deg
at 20m
Road
RTP Layout RTP Layout RTP Layout RTP Layout
READY FOR ELECTRONICS1 SURVEY FORM
Circle: Delhi Site Name/IP Site Name: ABC Site ID/IP Site ID: 123
N=0°
Drawing should be with respect to North
2013 © Samsung Electronics 35
ROAD
2D
RT Layout (if IFC provided)RT Layout (if IFC provided)RT Layout (if IFC provided)RT Layout (if IFC provided)
READY FOR ELECTRONICS1 SURVEY FORM
Circle: Delhi Site Name/IP Site Name: ABC Site ID/IP Site ID: 123
2013 © Samsung Electronics 37
Important PointsImportant PointsImportant PointsImportant Points
α
BBBB
RTT Top View
βγ
Cable TrayRRU3m
RRU to Vertical Cable Tray=RRU(vertical Ht with Buffer) to A+AB+B to Cable Tray
AAAA CCCC
Cables
Single Hole Pressure Terminal
2013 © Samsung Electronics 40
Layout- 2 Door ODC
2013 © Samsung Electronics 41
Layout- 3 Door ODC
2013 © Samsung Electronics 42
Airmarking-2/3 Door ODC3 Door ODC Possible position of CDU & CSS
Units Equipments in Rack 3
40 FAN(1U)
39
Future (4U)38
37
36
35BBU/DU (2U)
34
33 GAP (1U)
32
AG1 (3U)31
30
29 GAP (1U)
28WiFi(2U)
27
26 GAP (1U)
25
24
2 Door ODC Possible position of CDU & CSS
Units Equipments in Rack1
40 FAN(1U)
39 GAP (1U)
38BBU/DU (2U)
37
36 GAP (1U)
35 CSS(1U)
34 GAP(1U)
33WiFi(2U)
32
31
FDP(4U)30
29
28
27
26
25
24
2013 © Samsung Electronics 43
DWDM (12U)
24
23
22
21
20
19
18
17
16
15
14
13 GAP (1U)
12
OLT(12U)
11
10
9
8
7
6
5
4
3
2
1
SMPS(13U-14U)
24
23
22
21
20
19
18
17
16
15
14
13
BB(12U)
12
11
10
9
8
7
6
5
4
3
2
1
2 Door ODC Cable Position-Left hand side Roxtec
WiFi 2U
Samsung DU 2U
CSS
1U
Gap 1U
2m
DGPS Arrestor
If Roxtec on Left for
passing
CPRI,CNT-400 &
RRU Power A
RRU power
cables
CPRI cables
CNT-400 cable
DU grounding from
rear side
GPS ground cable
CNT-400 cable
ODC 2 Door Cable Routing with Roxtec on
Left side
2013 © Samsung Electronics 44
2m
0.65m
IGB-Electronics to be used to ground Samsung DU,GPS Surge Arrester & Cisco switch-CSS
Cable Inlet
CB
cables
SMPS with DCDB
either on left or right
side
cable
CNT-400
CPRI
RRU Power Cable
Ground Cable
DU Power Cable
DU Power Cable
DU position :37U & 38U in Rack 1
CSS position :35U in Rack 1
DU Ground Cable
2 Door ODC Cable Position-Right Hand side Roxtec
WiFi
2U
Samsung DU 2U
CSS
1U
Gap 1U
2m
XDGPS Surge Arrestor
Roxtec on
Right for
passing
CPRI,CNT-
400 &
RRU Power SMPS with DCDB
either on left or right
side
GPS Surge
Arrestor Ground
cable
DU grounding
from rear side
CPRI cables
CNT-400
cable
ODC 2 Door Cable Routing with Roxtec on
Right side
2013 © Samsung Electronics 45
0.65m
Y
C
IGB-Electronics to be used to ground Samsung DU,GPS Surge Arrester & Cisco switch-CSS
Cable Inlet
DU ground
cable from rear
of DU
CNT-400
CPRI
RRU Power
CableGround Cable
DU Power
Cable
B
DU power cable RRU Power
Cables
DU position :37U & 38U in Rack 1
CSS position :35U in Rack 1
3 Door ODC Cable Position
DU ground
cable from
Samsung CDU
2U
A
GPS
ArrestorAG1-3U
Roxtec No.1 position for
passing
CPRI & CNT-400
Roxtec No.2 will be
provided in future along
with Cable Tray to Pass
RRU Power cable
F
ODC 3 Door Cable Routing with only one Roxtec on
Right side
2013 © Samsung Electronics 46
DU power
cable
cable from
rear of DU
2m
IGB for
grounding
Samsung DU,
GPS Surge
ArrestorD
BC
Cable Inlet
position
Optional Path if Roxtec No.2 is not available/provided
CNT-400
CPRI
RRU Power Cable
Ground Cable
DU Power Cable
CE
DU position :34U-35U in Rack 3
AG1 position :30U-32U in Rack 3
RRU power
cables
DU power
cables
Gamsahapnida