CAT.200.01.T.E For more information contact Cutler-Hammer at: www.ch.cutler-hammer.com/catalog 12-63 January 2001 Molded Case Circuit Breakers 12 125 – 600 Amperes L-Frame Vol. 1, Ref. No. [0529] 100% Rated Digitrip OPTIM Circuit Breakers with Interchangeable Rating Plug Order as individual components: Breaker Frame (which includes Trip Unit), Rating Plug, Terminals. Table 12-103. 100% Rated Digitrip OPTIM 550 Circuit Breakers with Interchangeable Rating Plug 1 Long delay I 4 t response selection limits short delay time to flat response. 2 Zone Interlocking, PowerNet, or both features can be added at the factory by adding Suffixes ZG, PN or ZGP respectively to above Catalog Number (Refer to Page 12-184 and take list price Adder x 1.25). Note: Instruction Leaflet/FRED Number 29C105 for Breaker; 29C891 for OPTIM Trip Unit Maximum Continuous Ampere Rating @ 40°C Circuit Breaker Frame Only Digitrip OPTIM Rating Plug Only L – Adjustable Long Delay Pickup (I r ) with Adjustable Long Delay Time (I 2 t or I 4 t Response) 1 S – Adjustable Short Delay Pickup with Adjustable Short Delay Time (I 2 t or Flat Response) I – Adjustable Instantaneous Pickup G – Adjustable Ground Fault Pickup with Adjustable Ground Fault Time (I 2 t or Flat Response) A – Adjustable Ground Fault Alarm with Adjustable Ground Fault Time (I 2 t or Flat Response) Ampere Rating Fixed Rating Plug OPTIM 550 2 LSI LSIG LSIA Catalog Number Price U.S. $ Catalog Number Price U.S. $ Catalog Number Price U.S. $ Catalog Number Price U.S. $ 3-Pole Standard Interrupting Capacity 600V AC Rated 35 kAIC @ 480V AC 400 CLD3400T52W 8,010. CLD3400T56W 10,110. CLD3400T57W 9,110. 200 225 250 300 350 400 ORPL40A200 ORPL40A225 ORPL40A250 ORPL40A300 ORPL40A350 ORPL40A400 112. 112. 112. 112. 112. 112. 600 CLD3600T52W 8,710. CLD3600T56W 11,000. CLD3600T57W 9,890. 300 350 400 500 600 ORPL60A300 ORPL60A350 ORPL60A400 ORPL60A500 ORPL60A600 112. 112. 112. 112. 112. 3-Pole High Interrupting Capacity 600V AC Rated 65 kAIC @ 480V AC 400 CHLD3400T52W 10,240. CHLD3400T56W 12,340. CHLD3400T57W 11,110. 200 225 250 300 350 400 ORPL40A200 ORPL40A225 ORPL40A250 ORPL40A300 ORPL40A350 ORPL40A400 112. 112. 112. 112. 112. 112. 600 CHLD3600T52W 11,140. CHLD3600T56W 13,420. CHLD3600T57W 12,080. 300 350 400 500 600 ORPL60A300 ORPL60A350 ORPL60A400 ORPL60A500 ORPL60A600 112. 112. 112. 112. 112. 3-Pole Ultra High Interrupting Capacity Current Limiting 600V AC Rated 100 kAIC @ 480V AC 400 CLDC3400T52W 12,000. CLDC3400T56W 14,120. CLDC3400T57W 12,700. 200 225 250 300 350 400 ORPL40A200 ORPL40A225 ORPL40A250 ORPL40A300 ORPL40A350 ORPL40A400 112. 112. 112. 112. 112. 112. 600 CLDC3600T52W 13,040. CLDC3600T56W 15,340. CLDC3600T57W 13,810. 300 350 400 500 600 ORPL60A300 ORPL60A350 ORPL60A400 ORPL60A500 ORPL60A600 112. 112. 112. 112. 112. Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . . CB-2
Transcript
Page 1: Molded Case Circuit Breakers 12-63 125 – 600 Amperes

CAT.200.01.T.E For more information contact Cutler-Hammer at: www.ch.cutler-hammer.com/catalog

12-63January 2001

Molded Case Circuit Breakers

12

125 – 600 AmperesL-Frame

Vol. 1, Ref. No. [0529]

100% Rated Digitrip OPTIM Circuit Breakers with Interchangeable Rating PlugOrder as individual components: Breaker Frame (which includes Trip Unit), Rating Plug, Terminals.

Table 12-103. 100% Rated Digitrip OPTIM 550 Circuit Breakers with Interchangeable Rating Plug

1 Long delay I4t response selection limits short delay time to flat response.2 Zone Interlocking, PowerNet, or both features can be added at the factory by adding Suffixes ZG, PN or ZGP respectively to above Catalog Number

(Refer to Page 12-184 and take list price Adder x 1.25).Note: Instruction Leaflet/FRED Number 29C105 for Breaker; 29C891 for OPTIM Trip Unit

MaximumContinuousAmpereRating@ 40°C

Circuit Breaker Frame Only Digitrip OPTIM Rating Plug Only

L – Adjustable Long Delay Pickup (Ir) with Adjustable Long Delay Time (I2t or I4t Response) 1

S – Adjustable Short Delay Pickup with Adjustable Short Delay Time (I2t or Flat Response)I – Adjustable Instantaneous Pickup G – Adjustable Ground Fault Pickup with Adjustable Ground Fault Time (I2t or Flat Response)A – Adjustable Ground Fault Alarm with Adjustable Ground Fault Time (I2t or Flat Response)

Ampere Rating

Fixed Rating Plug

OPTIM 550 2

LSI LSIG LSIA

CatalogNumber

PriceU.S. $

Catalog

Number

PriceU.S. $

Catalog

Number

PriceU.S. $

Catalog

Number

PriceU.S. $

3-Pole Standard Interrupting Capacity 600V AC Rated 35 kAIC @ 480V AC400 CLD3400T52W 8,010. CLD3400T56W 10,110. CLD3400T57W 9,110. 200

225250300350400

ORPL40A200ORPL40A225ORPL40A250ORPL40A300ORPL40A350ORPL40A400

112.112.112.112.112.112.

600 CLD3600T52W 8,710. CLD3600T56W 11,000. CLD3600T57W 9,890. 300350400500600

ORPL60A300ORPL60A350ORPL60A400ORPL60A500ORPL60A600

112.112.112.112.112.

3-Pole High Interrupting Capacity 600V AC Rated 65 kAIC @ 480V AC400 CHLD3400T52W 10,240. CHLD3400T56W 12,340. CHLD3400T57W 11,110. 200

225250300350400

ORPL40A200ORPL40A225ORPL40A250ORPL40A300ORPL40A350ORPL40A400

112.112.112.112.112.112.

600 CHLD3600T52W 11,140. CHLD3600T56W 13,420. CHLD3600T57W 12,080. 300350400500600

ORPL60A300ORPL60A350ORPL60A400ORPL60A500ORPL60A600

112.112.112.112.112.

3-Pole Ultra High Interrupting Capacity Current Limiting 600V AC Rated 100 kAIC @ 480V AC400 CLDC3400T52W 12,000. CLDC3400T56W 14,120. CLDC3400T57W 12,700. 200

225250300350400

ORPL40A200ORPL40A225ORPL40A250ORPL40A300ORPL40A350ORPL40A400

112.112.112.112.112.112.

600 CLDC3600T52W 13,040. CLDC3600T56W 15,340. CLDC3600T57W 13,810. 300350400500600

ORPL60A300ORPL60A350ORPL60A400ORPL60A500ORPL60A600

112.112.112.112.112.

Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . . CB-2

TAB1202.fm Page 63 Wednesday, October 25, 2000 9:35 PM

Page 2: Molded Case Circuit Breakers 12-63 125 – 600 Amperes

12-52

For more information contact Cutler-Hammer at: www.ch.cutler-hammer.com/catalog CAT.200.01.T.E

January 2001

Molded Case Circuit Breakers

12

125 – 600 AmperesL-Frame

Vol. 1, Ref. No. [0518]

ContentsDescription Page

Product Description . . . . . . . . . 12-52

Technical Dataand Specifications . . . . . . . . . 12-52

Dimensions/Weights . . . . . . . . 12-54

Product Selection . . . . . . . . . . . 12-55

L-Frame

Typical L-Frame Circuit Breaker

Product Description■ All L-Frame Circuit Breakers are

HACR rated.■ L-Frame circuit breakers are available

as individual components (Frame, Trip Unit, Terminals), or factory assembled complete breakers.

■ L-Frame circuit breakers with non-interchangeable trip units are suitable for reverse feed use.

Technical Data and SpecificationsTable 12-84. UL489 Interrupting Capacity Ratings 1

1 Utilization category A circuit breakers.2 L/R = 8 milliseconds minimum.3 2-pole circuit breaker or two poles of 3-pole circuit breaker. Incorporating Thermal-Magnetic trip

unit only.4 100% rated breakers.

Table 12-85. IEC 947-2 Interrupting Capacity Ratings 5

5 Utilization category A circuit breakers.6 L/R = 8 milliseconds minimum.7 2-pole circuit breaker or two poles of 3-pole circuit breaker. Incorporating Thermal-Magnetic trip

unit only.8 100% rated breakers.

Circuit Breaker Type

Number of Poles

Interrupting Capacity (rms Symmetrical Amperes) (kA)

Volts AC (50/60 Hz) Volts DC

240 277 480 600 125 250 23 500

LDBLDCLDHLDCHLD 4

2, 3 2, 3, 4 2, 3, 42, 3, 42, 3, 4

656565

100100

—————

3535356565

2525253535

—————

2222222525

—————

LDCCLDC 4

2, 3, 42, 3, 4

200200

——

100100

5050

——

3030

——

Circuit BreakerType

Numberof Poles

Interrupting Capacity (Symmetrical Amperes) (kA)

Volts AC (50/60 Hz) Volts DC

240 415 690 250 67

Icu Ics Icu Ics Icu Ics Icu Ics

LDBLDCLD 8HLD

2, 32, 3, 42, 3, 42, 3, 4

858585

100

858585100

45454570

45454570

20202025

10101013

20202020

10101010

CHLD 8LDCCLDC 8

2, 3, 42, 3, 42, 3, 4

100200200

100100100

70100100

707575

253535

131818

202020

101010

TAB1202.fm Page 52 Wednesday, October 25, 2000 9:35 PM

Page 3: Molded Case Circuit Breakers 12-63 125 – 600 Amperes

CAT.200.01.T.E For more information contact Cutler-Hammer at: www.ch.cutler-hammer.com/catalog

12-55January 2001

Molded Case Circuit Breakers

12

125 – 600 AmperesL-Frame

Vol. 1, Ref. No. [0521]

Product SelectionThis information is presented only as an aid to understanding Catalog Numbers. It is not to be used to build Catalog Numbers for circuit breakers or trip units.

Table 12-89. Circuit Breaker/Frame Catalog Numbering System

Table 12-90. Thermal-Magnetic Trip Unit Catalog Numbering System

Table 12-91. OPTIM Circuit Breaker/Frame Catalog Numbering System

Table 12-92. Digitrip RMS 310 Trip Unit Catalog Numbering System

L D 3 6 0 0 F

Circuit Breaker/Frame Type

LDBLDHLDLDCCLDCHLDCLDC

Number of Poles

2 = 2 Poles3 = 3 Poles4 = 4 Poles

Circuit Breaker/Frame Ampere

Rating

300 350 400 450 500 600

Suffix

C = Copper TerminalsF = Frame OnlyK = High Magnetic

Molded Case SwitchV = 50°C (Thermal-Magnetic

Trip Units Only)W = Without TerminalsX = Load Side Terminals OnlyY = Line Side Terminals Only

L T 3 4 0 0 T

Trip Unit Type

LT = ThermalMagnetic

Number of Poles

2 = 2 Poles3 = 3 Poles4 = 4 Poles

Trip Unit Rating/Plug Ampere Rating

300 350 400 450 500 600

Suffix

T = Trip UnitThermal-MagneticFixed ThermalAdjustable Magnetic

V = 50°C Calibration(Thermal-MagneticTrip Units Only)

L D 3 1 2 5 T 5 7 W

Circuit Breaker/Frame Type

LDHLDLDCCLDCHLDCLDC

Trip Type

2 = LSI (550 Only)6 = LSIG 7 = LSIA

Suffix

W = Without Terminals

Circuit Breaker/Frame Ampere Rating

125(Available on Model 1050 only)

250(Available on Model 1050 only)

400600

Number of Poles

3 = 3 Poles

Trip Model

T5 = Model 550T10 = Model 1050

L E S 3 6 0 0 L S P

Trip Unit Type

LES = Electronic

Number of Poles

3 = 3 Poles4 = 4 Poles

Suffix

P = 100% Protected Neutral on 4-Pole Trip Unit

Suffix

LSLSILSGLSIG

Trip Unit Ampere Rating

600

TAB1202.fm Page 55 Wednesday, October 25, 2000 9:35 PM

Page 4: Molded Case Circuit Breakers 12-63 125 – 600 Amperes

12-184

For more information contact Cutler-Hammer at: www.ch.cutler-hammer.com/catalog CAT.200.01.T.E

January 2001

Molded Case Circuit Breakers

12

Internal AccessoriesPowerNet and Zone Interlock Kits

Vol. 1, Ref. No. [0650]

Cutler-Hammer PowerNet and Zone Interlock Kits (OPTIM 550 only) K-, L- and N-Frames

Figure 12-31. PowerNet Communication Kit

The Cutler-Hammer PowerNet Com-munications Kit can be ordered to add Cutler-Hammer PowerNet communica-tions to an existing OPTIM 550 breaker in the field. An 18-inch wiring pigtail is routed to the rear of the breaker: two wires for Cutler-Hammer PowerNet and two wires for 24V DC (45 mA load). It is recommended that the power supply be an “isolated high quality” unit.

Table 12-364. PowerNet and Zone Interlock Kits

1 Includes a ground fault alarm signal which can drive the Ground Fault Alarm unit (Catalog Number GFAU).

Note: Instruction Leaflet/FRED Numbers (K) 29C506, (L) 29C897, (N) 29C898

Circuit Breaker

PowerNet Zone Interlocking/Ground 1

PowerNet & Zone Interlocking/Ground 1

Catalog Number

FactoryInstall Suffix

PriceU.S. $

Catalog Number

FactoryInstall Suffix

PriceU.S. $

Catalog Number

FactoryInstall Suffix

PriceU.S. $

K-FrameL-FrameN-Frame

ICK550KICK550LICK550N

PNPNPN

351.454.560.

ZGK550KZGK550LZGK550N

ZGZGZG

315.410.505.

ZGPK550KZGPK550LZGPK550N

ZGPZGPZGP

405.525.645.

Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . . CB-2

TAB1206.fm Page 184 Wednesday, October 25, 2000 9:26 PM