Integrates with existing Building Management Systems Primary and Secondary heating circuits within same cable TURBO HEAT Automatically compensates for extremes in temperature Sustainable and Energy Efficient Monitored Thermal Protection for Sprinkler Pipework Designed for automatic fire sprinkler systems Designed to meet BS EN 62395-1:2006 Quickly Test Integrity of Heating Cable Constant Monitoring Notification of faults
Transcript
Page 1: Monitored Thermal Protection for Sprinkler Pipework · 2013-09-05 · BS EN 62395-1:2006 Quickly Test Integrity of Heating Cable Constant Monitoring Notification of faults. ... designed

Integrates with existing BuildingManagement Systems

Primary and Secondaryheating circuits within

same cable

TURBO HEATAutomatically compensatesfor extremes in temperature

Sustainable and EnergyEfficient

Monitored Thermal Protection for Sprinkler Pipework

Designed for automatic firesprinkler systems

Designed to meetBS EN 62395-1:2006

Quickly Test Integrity ofHeating Cable

Constant MonitoringNotification of faults

Dan Macey
1
Page 2: Monitored Thermal Protection for Sprinkler Pipework · 2013-09-05 · BS EN 62395-1:2006 Quickly Test Integrity of Heating Cable Constant Monitoring Notification of faults. ... designed

The ProMinder Advanced Heat System has been developedto provide a heating system with high reliability and built­infault tolerance and monitoring as well as simplifyinginstallation and maintenance for a range of applicationsincluding pipe frost protection. The system has beendesigned to meet the requirements of BS EN 12845 section11.1.2.2 and specifically for the automatic fire sprinklerindustry.

A range of eight cables provide frost protection for pipingfrom 5m – 150m. The controller allows the heat output to beselected during installation of 10W/m, 15W/m and 20W/m.Automatic turbo heat provides a rapid heat­up and powerboost in extreme cold environments.

• Patent Pending• Complies withBS EN 62395­1:2006

• Simple to install• 8 colour coded wires to coverpiping between 5m ­ 150m

• Fully earthed protectedcable for maximum safety

• IPX7 rated cable• IP65 rated controller

Technical DataDimensions (controller): 182mm(W) x 180mm(H) x 90mm(D)Construction (wire): Tri­core heating element with integral earth coverInsulation: Double insulatedVoltage: 240Vac 50/60HzApprovals: CE Marked, RoHS CompliantWire Overall Diameter: 6.35mm ±0.2mmMinimum Bend Radius: 25mmPower Range: 100W – 3000W (10W/m, 15W/m, 20W/m)IP Rating (wire): IPX7IP Rating (controller): IP65

Construction (Wire)Thermal Conductor: 3x 105˚C rated tough polymer insulated

resistance wiresOuter Insulation: Ultra­tough polymer protective coatingEarth Protection: 24x ø0.2mm low resistance alloy &

100% coverage polyester­backed aluminium foil

OVERVIEW

FEATURESHeaterWire From To

1 5m 9m2 9m 15m3 15m 25m4 25m 42.5m5 42.5m 60m6 60m 92m7 92m 120m8 120m 150m

Length (of piping)

• Fault output for connection toBMS/SCADA system

• TURBO Heat• Sustainable and energy efficient• Primary and secondaryheater circuit within one wire

• Automatic switch­over if oneheater circuit fails

• M2M capable

http://tinyurl.com/8kw77p2

Notification of Faults

Constant monitoring24/7 365 days a year

Checks both heatercircuits every minute

Quickly test integrityof each circuit