• Always Follow
• National Code
• State Code
• Local Code
• National Electric Code (NEC)
• When No Code Exists the Code Defaults to the NEC
• Licensing and Insurance
• What are the Licenses Required?
• Are Employees Covered for Electrical and other Trade Work?
Code and Insurance
Property of Worthington Distribution.
May Not Be Reproduced Without Permission
Motorizing Tilt Blinds
• Action: Motorization causes the louvers to tilt
• Power• Solar• Battery• Plug-in
• Control: RTS Wireless
Property of Worthington Distribution.
May Not Be Reproduced Without Permission
1.5” to 2 ¼” High
• Worthington Distribution offers a retrofit solutions
• Start with 2” Blinds
• The head rail should be 1.5” to 2 ¼” High
2” Louvers
Retrofitting Blinds
Property of Worthington Distribution.
May Not Be Reproduced Without Permission
Ordering: Motor and Adapters
• Start with the SOM1000678 Tilt Motor
• Tilt motor with a 30 lbs. tilt capacity
• Power: 12VDC
• Add a head rail adapter
• SOM9014529: Headrail Adapter for 2” x 2 1/4” Headrails
• SOM9014528: Low Profile Adapter for1.5” x 2 1/4” Headrails
• Look at the main shaft in the headrail
• Choose a matching adapter
• If the shaft is 1/4” square, no adapter is needed
9014536 9014535
4mm square9014540
Property of Worthington Distribution.
May Not Be Reproduced Without Permission
Ordering: Solar Power
• Solar Battery Charger• 5 year warranty• Mounts in a window and charges the battery
• Solar batteries must be charged before use• Order a SOM9015781 Pre-installationAC charger
• Typical pre-installation is 24 hours
Solar charging kit: 9015575
Property of Worthington Distribution.
May Not Be Reproduced Without Permission
Ordering: Battery or AC Power
• Re-loadable Battery Tube• Use with 8 lithium batteries (9014834)• For extended battery life or heavy treatments, use a 9105580 Y cable to wire two tubes in parallel
• Dual battery wands typically extend battery life by 75 percent
• Add Wall Mounting Clips for the Battery Tube (9013263) – 1 pair
Re-loadable battery tube: 9014020
Battery Y cable: 9015580
12VDC Plug-in Power Supply: 1822192
• Plug-In Power Supply• A great solution when wires can be run
Property of Worthington Distribution.
May Not Be Reproduced Without Permission
Ordering: Blind Motor RTS Controls
• The tilt motor is controlled by Somfy RTS• For manual control use the Modulis Remotes
• Tilt ‘wheel’ for precise control• Single or 5 channel control
• Advantages of RTS Technology• 65 foot installed range• The RTS radio receiver is integrated directly into the motor
• Control a variety or motor types from a single device
• A channel can control one or many treatments with a single button press
• Reliable• More 10 million installations worldwide • 13.4 million Rolling Codes•Multiple Channels
5 channel RTS ControllersPure
1810765Silver
1810663Lounge1810664
1 channel RTS ControllersPure
1810974Silver
1810975Lounge1810976
Property of Worthington Distribution.
May Not Be Reproduced Without Permission
Ordering: Other RTS Remotes
•Use the 16 channel controller for large installations
•DecoFlex WireFree wall mounted RTS keypads are available in 5,4,3,2 and 1 channel configurations
•There are 56 word choices for key labels available
•Use the DecoFlex base to create a great tabletop controller
16 channel RTS Controller
5 channel RTS DecoFlexWhite
1810813Ivory
1810814Black180830
Almond1811181
Base for DecoFlexWhite
1811185Silver
1810972Black
1811051
Pure1811081
Silver1811082
Property of Worthington Distribution.
May Not Be Reproduced Without Permission
Ordering: RTS Timer / Light Control
•Somfy RTS Controls can provide simple window treatment control•Use indoor light and/or temperature to control window treatment position
•Move window treatment positions from a handheld Chronis timer
•The Chronis Comfort is the easy way to control a single or group of window treatments•Control up to 4 up/down positions per day
1805176: 1 channel RTS Chronis Comfort
9709686: Chronis Comfort Sun Sensor
9013707: RTS Indoor Light9013708: Adds
Temperature Sensing
6 channel RTS Chronis TimerPure
1805217Silver
1805218
Property of Worthington Distribution.
May Not Be Reproduced Without Permission
• The Universal RTS Interface II (URTSI II) can be used to communicate between third party systems and Somfy's RTS Motors
• Capable of individual or group control, and can be operated via infrared remote, RS232 and RS485 (HAI) serial communication
• More than one URTSI II can be used in a system
• Start with channel 1 (not 0)
• Worthington Distribution offers a pre-made and tested cable for connecting an URTSI II and anHAI controller: SOMHAICBL $9.99
Universal RTS Interface
Control: RTS Integration
Property of Worthington Distribution.
May Not Be Reproduced Without Permission
• RTS Contact closure interface
• (3) Dry Contacts
• Tilt Up / Tilt Down / Stop or Preset
• Momentary contact only
• Separate relay up, down and if applicable stop
• Control individual blinds or a group of blinds
RTS Contact Closure InterfaceRTS Transmitter
Cat No. SOM1810493
RTS Contact Closure
Property of Worthington Distribution.
May Not Be Reproduced Without Permission
• The RTS Repeater receives the signal from an RTS transmitter and re-transmits the signal to an RTS compatible motor or receiver
• Simply plugs into any 120V AC electrical outlet, no programming required
• Should be placed at least halfway between the transmitting device such as a Telis hand-held remote and the receiving device, the motor
• Solves the challenge of transmitting the signal in particularly large rooms or areas
• One repeater can be used in an installation
Ordering: RTS Repeater
Property of Worthington Distribution.
May Not Be Reproduced Without Permission
Motorization of Blinds
Property of Worthington Distribution.
May Not Be Reproduced Without Permission
Motorization of Blinds
Property of Worthington Distribution.
May Not Be Reproduced Without Permission
Motorization of Blinds
Property of Worthington Distribution.
May Not Be Reproduced Without Permission
•RTS Learning•Motors are shipped in Factory Mode without limit settings and transmitter ID’s• Power must ONLY be connected to current window covering being programmed
• All other window coverings must be disconnected from their respective power while programming
RTS Setup – Power During Learn
Property of Worthington Distribution.
May Not Be Reproduced Without Permission
• On the multi-channel remote select a channel• Traditional setup is to assign channels 1 – 4 to shades 1,2,3 and 4.
• Traditionally channel 5 is used to communicate with all of the Blinds as a group
• Place the motor in program mode• On the transmitter press and hold Up and Down
• The blind motor will jog: A jog is a brief open/close motion
• In Programming Mode, the window covering will move only when the Up or Down is held
• Confirm the motor direction• Up = Open and Down should = Down• To change motor direction
• Press and hold the My button, the motor will jog
DownUp
RTS Setup – Channel ID & Direction
Property of Worthington Distribution.
May Not Be Reproduced Without Permission
• Setting Limits• Rotate the blind to desired Open limit by rotating the wheel in the Up direction
• Press and hold both My and Down simultaneously until the motor starts to move, then release
• If the motor stops when the buttons are released, take it back to the Open limit and repeat
• Stop the motor when reaching the desired Closed position
• You can adjust the position with the wheel after stopping the motor
• Press and hold both My and Up simultaneously until the motor starts to move, then release
• The window covering will stop at the Open limit that was previously set
• Press and hold My until the motor jogs• Press and hold the Programming Button on the back of the transmitter until the motor jogs
DownUp
Programming Button
RTS Setup – Limit Setting
Property of Worthington Distribution.
May Not Be Reproduced Without Permission
• User Mode• Setting a My position
• Use the wheel to set the blind to an intermediate position that you would like to assign to the My button
• Press and hold the My button until the motor jogs• Adjusting the Limits in User Mode
• Closed Limit• Press Down to close the blind• Press and hold both Up and Down simultaneously until the motor jogs
• Adjust to a new Closed position• Press and hold My until the motor jogs
• Open Limit• Press Up to open the blind• Press and hold both Up and Down simultaneously until the motor jogs
• Adjust to a new Open position• Press and hold My until the motor jogs
DownUp
RTS Setup – Limit Setting
Property of Worthington Distribution.
May Not Be Reproduced Without Permission
•Select a programmed transmitter• If deleting a transmitter, use a remote that will be staying in the system
•Press the Programming Button on the remote and the motor will jog
•Press the Programming Button on the remote to be added / removed and the motor will jog
Programming Button
RTS Setup – Add or Remove Transmitters
Property of Worthington Distribution.
May Not Be Reproduced Without Permission
•To Delete ALL Transmitter Channels: •Using a paperclip, press and hold the Program Button located on the motor head casing until blind jogs 2 times then release
•To Delete all Previous Settings:•Using a paperclip, press and hold the Program Button, located on the top of the motor casing until window covering jogs 3 times, then release button• All transmitters and limits will be erased
Prog Button
RTS Setup – Factory Reset
Property of Worthington Distribution.
May Not Be Reproduced Without Permission
•Adding the URTSII to a system• Using the rotary switch, select the channel to be programmed
• Letter A through F stand for channels 10 through 15, 0 for 16
• Do not use 0 (most installations use 1)• Press the Program button on the back of an existing RTS remote
• Briefly press the Programming Button on the front of the URTSII
• The motor will jog to indicate the channel has been memorized
• Repeat for additional channels• Use the Up/Down/Stop buttons for testing
• Set the dial to the channel being tested•When sending serial messages the dial represents the URTSII address
HAI Integration – Adding the URTSII
Property of Worthington Distribution.
May Not Be Reproduced Without Permission
Pro-Link
• Use RS-485 and ProLink• Although the URTSII shows an RS-232 connection it is incompatible with HAI
• Set the Port jumper to RS-485
• Send HAI Messages to control the blind•Messages UR CH DIR• UR = Address: 01 to 16 (2 digits)• CH = Channel: 01 to 16 (2 digits)• DIR = Direction: U = Up D = Down S = Stop (Must be Capital letters)
• Examples:• URTSII 1, Channel 1 UP: 0101U• URTSII 3, Channel 12 DOWN: 0312D
• Worthington Distribution offers a pre-made and tested cable for connecting an URTSI II and an HAI controller: SOMHAICBL $9.99
HAI Integration – HAI Setup
Property of Worthington Distribution.
May Not Be Reproduced Without Permission
Worthington Distribution
• Worthington Distribution Can Provide
• Product
• Competitive Pricing
• Great Stocking Levels in Tafton, PA
• Knowledgeable, Helpful Staff
• Training
• Worthington University
• On-Line
• Technical Support
• System Design Support
800-282-8864
Richard Scholl
President
Richie Scholl
VP, Technical
Sales
Debbie Scholl
Customer Service
Tom Morgan
VP, Worthington
University
Steve Hoh
Technical SupportBarry Hampe
Technical Support
Tricia Seybold
Customer Service
Manager
Nolan Male
Technical Support