Mouse Microsurgery and echocardiography
workshop
Vahagn Ohanyan, MD, PhD
Echo guided intra-myocardial and intra-ventricular injection
Stress echocardiography: measurement of cardiac function and blood pressure changes during stress test
A B
Surgical towel Ultrasound scanhead
Echo guided intra-myocardial and intra-ventricular injection
Preparation of mouse:
Selection of needle and syringes
CHamilton 10 l syrung
Intra-ventricular injectionVolume for bolus injection:Mice: < 50 ulRats~300g: <150 ulFor small volume injection use Hamilton needle(27-30G) and syringes (sterilize before using)
27 G Needle The tip of the needle
Echo guided insertion of 27G needle
LV Ventricle injectionVideo
Before Needle inside the LV Cavity
Injection of saline into LV VentricleVideo
Intra-myocardial Injection
• Use very small amount of solution to inject in one site. Large amount of the drug (solution can damage or rupture the ventricular wall).
• For mice 10-15 ul in one site • For rats 20-30 ul (~300 g rat)• Sterilize the needle before insertion.• Prepare the animal as described in intra-
ventricular injection section
The tip of the needle LV anterior wall
The tip of the needle
A
Positioning needle inside the LV wallVideo
Intra-myocardial injectionVedeo
Needle is inside the LV cavity Needle inside the LV Wall
PV Loop catheter insertion into LV ventricle trough carotid artery
• For carotid artery isolation, catheterization see page 53.
• Clean the mouse chest for echocardiography as described in transthoracic echocardiography section.
• Find parasternal long axis view and clear aortic root.
Parasternal long axis viewVideo
Pressure-volume catheter
Left ventricle
VideoPV catheter inside the LV cavity
Incorrect and correct position of the probe
Incorrect position Correct position
Stress echocardiography
• If you want to remove vagal reflex, treat the animals with ganglionic blocker Norepinephrine or Dobutaminecontinuous injection is commonly used for experimental protocols.
• Get all your measurement at plateau, which usually reaches after 30 second injection
Position of echo scanhead
• After finding the desirable position (M mode or Doppler) fix the probe and do not change any adjustments. All this must be constant.
Baseline During NE injection
SEE ONE , DO ONE ,
THEACH ONE, BECOME A CONTRIBUTRE