Date post: | 21-Dec-2015 |
Category: |
Documents |
View: | 214 times |
Download: | 0 times |
MPC-Sample-System
1 10MPC Sample System
6/17/04
MPC-Sample-System
© 2004 Swagelok Company. Swagelok confidential. For internal use only.
IFPAC SM 2005 Nineteenth International ForumProcess Analytical Technology
January 10-13, 2005 Arlington, Virginia (Washington, D.C.) U.S.A.
Software Simplifies Design and Layoutof
Real-life NeSSI Systems
John J. Wawrowski and David M. Simko Swagelok Company
IFPACIFPAC
MPC-Sample-System
2 10MPC Sample System
6/17/04
MPC-Sample-System
© 2004 Swagelok Company. Swagelok confidential. For internal use only.
IFPACIFPAC
Agenda
• Review of configurator features and functionality• Live configuration of an actual system
MPC-Sample-System
3 10MPC Sample System
6/17/04
MPC-Sample-System
P&ID for Sample System
Particle Filter, 2 Micron
Pressure Gauge, 0-30 psig
Pressure Regulator, 0-15 psig
Needle Valve, DK Series
Pneumatic Valve, NC
Rotameter, Brooks, 0-10 cc/min
Check Valve, crack 0-3 psi
Needle Valve, DK Series
Check Valve, crack 0-3 psi
PG
To Analyzer
QC Supply
Sample In from Process
© 2004 Swagelok Company. Swagelok confidential. For internal use only.
Step 1: Create Configurator Layout Grid
A. File -> New
PG
IFPACIFPAC
© 2004 Swagelok Company. Swagelok confidential. For internal use only.
Step 2: Place inlet(s) on the Layout Grid
A. To add these inlets…
B. Select this icon in the Toolbox…
PG
C. Then Drag it onto the Grid
IFPACIFPAC
© 2004 Swagelok Company. Swagelok confidential. For internal use only.
Step 3: Add Surface Mount Positions
C. Then Drag it onto the Grid
IFPACIFPAC
A. To Add this part…
PG
B. Select this icon in the Toolbox…
© 2004 Swagelok Company. Swagelok confidential. For internal use only.
Step 4 – Place outlets on GridA. To add this outlet…
B. Select this icon in the Toolbox…
PG
C. Then Drag it onto the Grid
IFPACIFPAC
© 2004 Swagelok Company. Swagelok confidential. For internal use only.
Current View after Step 4
IFPACIFPAC
© 2004 Swagelok Company. Swagelok confidential. For internal use only.
Step 5: Define Surface Mount PropertiesB. Right click here and select Properties. A. To Select
this part...
PG
C. To select a check valve…
D. Left click to select category here.
IFPACIFPAC
© 2004 Swagelok Company. Swagelok confidential. For internal use only.
IFPACIFPAC
Current View after Step 5
© 2004 Swagelok Company. Swagelok confidential. For internal use only.
Step 6: Connect Flow Paths
A. Left click starting node…
B. Valid flow path targets are displayed as green circles.
PG
IFPACIFPAC
© 2004 Swagelok Company. Swagelok confidential. For internal use only.
IFPACIFPAC
Current View after Step 6
© 2004 Swagelok Company. Swagelok confidential. For internal use only.
Step 7: Final Layout, BOM, and Assembly Diagram
IFPACIFPAC
© 2004 Swagelok Company. Swagelok confidential. For internal use only.
Step 8 – Save the File
A. File -> Save
PG
IFPACIFPAC
© 2004 Swagelok Company. Swagelok confidential. For internal use only.
Configurator Demonstration
Swagelok MPC Configurator.lnk
IFPACIFPAC
© 2004 Swagelok Company. Swagelok confidential. For internal use only.
Conclusion
• Please visit us at Booths 315/317– Complimentary copy of the software– Opportunity to use it– Opportunity to build a NeSSI system
IFPACIFPAC