MPV 75/150USER INTERFACEAARON CARDENAS
2
WEB INTERFACE
Detailed system information System Summary Energy Reports Configuration Device Information Event History
Real-time updates and control
Remote configuration
Easy remote upgrade/backup/restore
No software installation required
Compatible with all major browsers and devices (iOS/Android/Tablets/Phones)
Built-in
US
ER
INT
ER
FA
CE
Web Interface
3
SUMMARY PAGE SCREENSHOT
SU
MM
AR
Y P
AG
E W
eb Interface
4
SUMMARY PAGE
Instantaneous Power with Percent Bar (Shows percentage of output compared to capacity) kW Peak power for the current day (kW) Energy produced for the current day (kWhr) Graph behind the power readings highlighting power throughout the current day Input Voltage and Current Internal System Temperature (sensed from inside of the controller) Grid Information
− Voltage/Current/Frequency Alarm Information
− See manual for the complete list off alarms reported. Operating Time Commission Date Cabinet Serial Number (matches label on the side of the cabinet)
Footer (Visible on all pages) Alarm Status, Output Power, Operating Time, System Time, Model #, Serial #
SU
MM
AR
Y P
AG
E W
eb Interface
5
REPORTS PAGE SCREENSHOT
RE
PO
RT
S P
AG
E W
eb Interface
6
REPORTS PAGE
Day Graph Table showing the energy (kWhr) produced each hour of the day Line Graph shows the power thoughout the day. May select different days of data to view. Updated in real-time while viewing the page.
Month Graph Table in calendar format shows energy produced each day of the month. Bar Graph shows energy for each day of the month for easy comparison. May select different months of data to view.
Year Graph Table shows energy produced each month of the year. Bar Graph shows energy for each month of the year for easy comparison. May select different years of data to view.
RE
PO
RT
S P
AG
E W
eb Interface
7
DEVICES PAGE SCREENSHOT 1
DE
VIC
ES
PA
GE
Web Interface
8
DEVICES PAGE SCREENSHOT 2
DE
VIC
ES
PA
GE
Web Interface
9
DEVICES PAGE
Controller Info Output Power, Status, Serial, FW Version
Inverter Info Module output power, State (On, Off, Standby, Alarm), Status, Output Voltage/Current/Frequency, Input Voltage/Current, Temperature, Operating Time, Model, Serial, Vendor Code, FW versions. Module background changes color depending on module state.
Distribution Info• Analog Inputs (Input Voltage/Current)• Discrete Inputs (Door, GFI, AC/DC Switches, Surge Protection Devices)• Relay Outputs (Input Contactors, GFI Control)• If the state graphic is filled in, that indicates that the particular input/output is active/connected• Inputs/Outputs can be labeled on the configuration page.
DE
VIC
ES
PA
GE
Web Interface
10
DEVICES PAGE (List View) SCREENSHOT
DE
VIC
ES
PA
GE
(List V
iew) W
eb Interface
11
DEVICES PAGE (List View)
Tabular view of inverter parameters ID – Shelf slot location Output Power/Voltage/Current/Frequency Temperatures
Sortable
Updated in real-time
Easy comparison of each inverter module
DE
VIC
ES
PA
GE
(List V
iew) W
eb Interface
12
CONFIGURATION PAGE SCREENSHOT
CO
NF
IGU
RA
TIO
N P
AG
E W
eb Interface
13
CONFIGURATION PAGE
System Configuration Name, Description, Address, Commission Date, Date/Time, Temperature Units, GFI Control, Startup/Shutdown Control, LED Test. Login button is at the top right of the page.
Notifications Configure which e-mail address will receive alarms, event, and performance reports.
− Note: This feature requires an e-mail server to be configured on the network page.
Inverters Anti-Islanding configuration.
− WARNING: The default values on this configuration screen are set to meet the requirements of UL 1741 and IEEE 1547. Contact technical support before changing any of these values.
Input/Output Distribution input/output information.
− Name, Polarity, Alarm, Feedback, Pulse Time.
CO
NF
IGU
RA
TIO
N P
AG
E W
eb Interface
14
CONFIGURATION PAGE (continued)
Network IP Configuration Web Server Port E-mail server
User Account Web password Administrator e-mail address Local Access (Display) PIN number.
Backup/Restore Upload: Controller FW, Inverter FW, Distribution FW, Display FW, Configuration
− Conveniently upgrade system FW and configuration through one interface. Backup Configuration/Data Logs Reset to factory defaults
CO
NF
IGU
RA
TIO
N P
AG
E (co
ntin
ued
) Web Interface
15
EVENTS PAGE SCREENSHOT
EV
EN
TS
PA
GE
Web Interface
16
EVENTS PAGE
1000 events stored
Color coded
Sortable
Searchable
*See Table 6-2 System Faults in the manual for more information on events that are stored.
CO
NF
IGU
RA
TIO
N P
AG
E W
eb Interface
17
LOCAL INTERFACE
Main Screen Output Power Gauge Graphical representation of system state and configuration
− Blank = Slot Empty− Solid = Standby− Dotted = On− Cross = Alarm
Day/Month/Year Energy Graphs Alarms
Menu System Detailed view of system parameters and device parameters
Alarm Reporting
US
ER
INT
ER
FA
CE
Local Display
18
MENU TREE
Main Screen Date/Time, Input Voltage, Output Voltage/Current, Output Power Percent Bar Day, Month, Year Bar Graph Alarm Display Cabinet Display with animated icons
− Blank = Slot Empty− Solid = Standby− Dotted = On− Cross = Alarm
Main Menu Alarms Data
− Array
Power, Current, Voltage, DC Switch Status, Contactor Positive/Negative Status− Cabinet
Number of inverters, Operating Hours, Remote Shutdown State
US
ER
INT
ER
FA
CE
Local Display
19
MENU TREE (continued)
Main Menu Data
− Inverter
Summary with power output– State, Status, Output Power, Energy Today, Capacity, Temperatures, Input Voltage/Current
− Grid
Power, Energy Today, Voltage/Current (Phase ABC), Frequency, AC Switch Status− Clock
Date/Time, Day of Week− Network
IP Address Summary– Link status, State
Configuration− System
Location, Commission Date, Cabinet Serial, Model, Temperature Units, Hardware Revision, Mail Server/Port/Username, HTTP Port.
US
ER
INT
ER
FA
CE
Local Display
20
MENU TREE (continued)
Main Menu Configuration
− Display
FW Version Application/Bootloader− Inverter
Model, Serial, Vendor, FW Versions, Manufacturing Date− Clock
Date Format, Time Format, SNTP Server, Time Zone, Daylight Savings, DS Start/End, − Network
Type, IP, Gateway, Mask, DNS, MAC Actions
− Login (Default PIN: 1234)− Reset GFI− System Control (Start/Shutdown)− Change Display PIN
Display Settings− Beep, Inverter Colors, Language, Demo Mode
US
ER
INT
ER
FA
CE
Local Display
21
Future Development
Aggregated view of multiple cabinets from one interface
Weather station information display
3rd party monitoring support
Improvements to the reports page Graph annotations (mouse-over information) New information (i.e. Temperature plots) Custom comparisons (Compare different days, month, years)
FU
TU
RE
DE
VE
LO
PM
EN
T