MPV 75/150 USER INTERFACE. AARON CARDENAS. WEB INTERFACE. Detailed system information System Summary Energy Reports Configuration Device Information Event History Real-time updates and control Remote configuration Easy remote upgrade/backup/restore No software installation required - PowerPoint PPT Presentation
21
MPV 75/150 USER INTERFACE AARON CARDENAS
Transcript
Page 1: MPV 75/150 USER INTERFACE

MPV 75/150USER INTERFACEAARON CARDENAS

Page 2: MPV 75/150 USER INTERFACE

2

WEB INTERFACE

Detailed system information System Summary Energy Reports Configuration Device Information Event History

Real-time updates and control

Remote configuration

Easy remote upgrade/backup/restore

No software installation required

Compatible with all major browsers and devices (iOS/Android/Tablets/Phones)

Built-in

US

ER

INT

ER

FA

CE

Web Interface

Page 3: MPV 75/150 USER INTERFACE

3

SUMMARY PAGE SCREENSHOT

SU

MM

AR

Y P

AG

E W

eb Interface

Page 4: MPV 75/150 USER INTERFACE

4

SUMMARY PAGE

Instantaneous Power with Percent Bar (Shows percentage of output compared to capacity) kW Peak power for the current day (kW) Energy produced for the current day (kWhr) Graph behind the power readings highlighting power throughout the current day Input Voltage and Current Internal System Temperature (sensed from inside of the controller) Grid Information

− Voltage/Current/Frequency Alarm Information

− See manual for the complete list off alarms reported. Operating Time Commission Date Cabinet Serial Number (matches label on the side of the cabinet)

Footer (Visible on all pages) Alarm Status, Output Power, Operating Time, System Time, Model #, Serial #

SU

MM

AR

Y P

AG

E W

eb Interface

Page 5: MPV 75/150 USER INTERFACE

5

REPORTS PAGE SCREENSHOT

RE

PO

RT

S P

AG

E W

eb Interface

Page 6: MPV 75/150 USER INTERFACE

6

REPORTS PAGE

Day Graph Table showing the energy (kWhr) produced each hour of the day Line Graph shows the power thoughout the day. May select different days of data to view. Updated in real-time while viewing the page.

Month Graph Table in calendar format shows energy produced each day of the month. Bar Graph shows energy for each day of the month for easy comparison. May select different months of data to view.

Year Graph Table shows energy produced each month of the year. Bar Graph shows energy for each month of the year for easy comparison. May select different years of data to view.

RE

PO

RT

S P

AG

E W

eb Interface

Page 7: MPV 75/150 USER INTERFACE

7

DEVICES PAGE SCREENSHOT 1

DE

VIC

ES

PA

GE

Web Interface

Page 8: MPV 75/150 USER INTERFACE

8

DEVICES PAGE SCREENSHOT 2

DE

VIC

ES

PA

GE

Web Interface

Page 9: MPV 75/150 USER INTERFACE

9

DEVICES PAGE

Controller Info Output Power, Status, Serial, FW Version

Inverter Info Module output power, State (On, Off, Standby, Alarm), Status, Output Voltage/Current/Frequency, Input Voltage/Current, Temperature, Operating Time, Model, Serial, Vendor Code, FW versions. Module background changes color depending on module state.

Distribution Info• Analog Inputs (Input Voltage/Current)• Discrete Inputs (Door, GFI, AC/DC Switches, Surge Protection Devices)• Relay Outputs (Input Contactors, GFI Control)• If the state graphic is filled in, that indicates that the particular input/output is active/connected• Inputs/Outputs can be labeled on the configuration page.

DE

VIC

ES

PA

GE

Web Interface

Page 10: MPV 75/150 USER INTERFACE

10

DEVICES PAGE (List View) SCREENSHOT

DE

VIC

ES

PA

GE

(List V

iew) W

eb Interface

Page 11: MPV 75/150 USER INTERFACE

11

DEVICES PAGE (List View)

Tabular view of inverter parameters ID – Shelf slot location Output Power/Voltage/Current/Frequency Temperatures

Sortable

Updated in real-time

Easy comparison of each inverter module

DE

VIC

ES

PA

GE

(List V

iew) W

eb Interface

Page 12: MPV 75/150 USER INTERFACE

12

CONFIGURATION PAGE SCREENSHOT

CO

NF

IGU

RA

TIO

N P

AG

E W

eb Interface

Page 13: MPV 75/150 USER INTERFACE

13

CONFIGURATION PAGE

System Configuration Name, Description, Address, Commission Date, Date/Time, Temperature Units, GFI Control, Startup/Shutdown Control, LED Test. Login button is at the top right of the page.

Notifications Configure which e-mail address will receive alarms, event, and performance reports.

− Note: This feature requires an e-mail server to be configured on the network page.

Inverters Anti-Islanding configuration.

− WARNING: The default values on this configuration screen are set to meet the requirements of UL 1741 and IEEE 1547. Contact technical support before changing any of these values.

Input/Output Distribution input/output information.

− Name, Polarity, Alarm, Feedback, Pulse Time.

CO

NF

IGU

RA

TIO

N P

AG

E W

eb Interface

Page 14: MPV 75/150 USER INTERFACE

14

CONFIGURATION PAGE (continued)

Network IP Configuration Web Server Port E-mail server

User Account Web password Administrator e-mail address Local Access (Display) PIN number.

Backup/Restore Upload: Controller FW, Inverter FW, Distribution FW, Display FW, Configuration

− Conveniently upgrade system FW and configuration through one interface. Backup Configuration/Data Logs Reset to factory defaults

CO

NF

IGU

RA

TIO

N P

AG

E (co

ntin

ued

) Web Interface

Page 15: MPV 75/150 USER INTERFACE

15

EVENTS PAGE SCREENSHOT

EV

EN

TS

PA

GE

Web Interface

Page 16: MPV 75/150 USER INTERFACE

16

EVENTS PAGE

1000 events stored

Color coded

Sortable

Searchable

*See Table 6-2 System Faults in the manual for more information on events that are stored.

CO

NF

IGU

RA

TIO

N P

AG

E W

eb Interface

Page 17: MPV 75/150 USER INTERFACE

17

LOCAL INTERFACE

Main Screen Output Power Gauge Graphical representation of system state and configuration

− Blank = Slot Empty− Solid = Standby− Dotted = On− Cross = Alarm

Day/Month/Year Energy Graphs Alarms

Menu System Detailed view of system parameters and device parameters

Alarm Reporting

US

ER

INT

ER

FA

CE

Local Display

Page 18: MPV 75/150 USER INTERFACE

18

MENU TREE

Main Screen Date/Time, Input Voltage, Output Voltage/Current, Output Power Percent Bar Day, Month, Year Bar Graph Alarm Display Cabinet Display with animated icons

− Blank = Slot Empty− Solid = Standby− Dotted = On− Cross = Alarm

Main Menu Alarms Data

− Array

Power, Current, Voltage, DC Switch Status, Contactor Positive/Negative Status− Cabinet

Number of inverters, Operating Hours, Remote Shutdown State

US

ER

INT

ER

FA

CE

Local Display

Page 19: MPV 75/150 USER INTERFACE

19

MENU TREE (continued)

Main Menu Data

− Inverter

Summary with power output– State, Status, Output Power, Energy Today, Capacity, Temperatures, Input Voltage/Current

− Grid

Power, Energy Today, Voltage/Current (Phase ABC), Frequency, AC Switch Status− Clock

Date/Time, Day of Week− Network

IP Address Summary– Link status, State

Configuration− System

Location, Commission Date, Cabinet Serial, Model, Temperature Units, Hardware Revision, Mail Server/Port/Username, HTTP Port.

US

ER

INT

ER

FA

CE

Local Display

Page 20: MPV 75/150 USER INTERFACE

20

MENU TREE (continued)

Main Menu Configuration

− Display

FW Version Application/Bootloader− Inverter

Model, Serial, Vendor, FW Versions, Manufacturing Date− Clock

Date Format, Time Format, SNTP Server, Time Zone, Daylight Savings, DS Start/End, − Network

Type, IP, Gateway, Mask, DNS, MAC Actions

− Login (Default PIN: 1234)− Reset GFI− System Control (Start/Shutdown)− Change Display PIN

Display Settings− Beep, Inverter Colors, Language, Demo Mode

US

ER

INT

ER

FA

CE

Local Display

Page 21: MPV 75/150 USER INTERFACE

21

Future Development

Aggregated view of multiple cabinets from one interface

Weather station information display

3rd party monitoring support

Improvements to the reports page Graph annotations (mouse-over information) New information (i.e. Temperature plots) Custom comparisons (Compare different days, month, years)