+ All Categories
Home > Documents > MTU/DDC Stationary Power Generation Series 2000 · PDF filemonitoring and control integrated...

MTU/DDC Stationary Power Generation Series 2000 · PDF filemonitoring and control integrated...

Date post: 01-Feb-2018
Category:
Upload: lamtruc
View: 414 times
Download: 18 times
Share this document with a friend
21
MTU/DDC MTU/DDC Stationary Power Generation Stationary Power Generation Series 2000 Engines Series 2000 Engines
Transcript
Page 1: MTU/DDC Stationary Power Generation Series 2000 · PDF filemonitoring and control integrated to the engine. ... MDEC Electonic System ... MTU/DDC Stationary Power Generation Series

MTU/DDC MTU/DDC Stationary Power Generation Stationary Power Generation

Series 2000 EnginesSeries 2000 Engines

Page 2: MTU/DDC Stationary Power Generation Series 2000 · PDF filemonitoring and control integrated to the engine. ... MDEC Electonic System ... MTU/DDC Stationary Power Generation Series

207.10.2005DaimlerChrysler Off-Highway SGC - Binkle

MTU/DDC Stationary Power Generation Series 2000 Engines

Page 3: MTU/DDC Stationary Power Generation Series 2000 · PDF filemonitoring and control integrated to the engine. ... MDEC Electonic System ... MTU/DDC Stationary Power Generation Series

307.10.2005DaimlerChrysler Off-Highway SGC - Binkle

MTU/DDC Stationary Power Generation Series 2000 Engines

Cylinder Configurations: 12 / 16 / 18V

Ratings: 452 to 1250 kW

Speeds: 1500 & 1800 rpm

Switchable 1500 – 1800 rpm

Optimizations: FCO / EPA Tier 1 / TAL

Page 4: MTU/DDC Stationary Power Generation Series 2000 · PDF filemonitoring and control integrated to the engine. ... MDEC Electonic System ... MTU/DDC Stationary Power Generation Series

407.10.2005DaimlerChrysler Off-Highway SGC - Binkle

MTU/DDC Stationary Power Generation Series 2000 Engines

1500

rpm

–50

Hz

kW kVA

400

500

600

700

800

900

1000

1100

1200

1100

1000

900

800

750

700

600

500

400

3D

18V 2000 G63

16V 2000 G63

16V 2000 G23

12V 2000 G63

12V 2000 G23

3B

18V 2000 G63

16V 2000 G63

16V 2000 G23

12V 2000 G63

12V 2000 G23

300

3A

12V 2000 G63

16V 2000 G63

18V 2000 G63

12V 2000 G23

350

Power Rating 50 Hz

Standby Prime Continuous

Page 5: MTU/DDC Stationary Power Generation Series 2000 · PDF filemonitoring and control integrated to the engine. ... MDEC Electonic System ... MTU/DDC Stationary Power Generation Series

507.10.2005DaimlerChrysler Off-Highway SGC - Binkle

MTU/DDC Stationary Power Generation Series 2000 Engines

500

1800

rpm

–60

Hz

kW kW el

1100

600

700

800

900

1000

1100

1200

1300

1000

800

750

700

600

3D

18V 2000 G83

16V 2000 G83

16V 2000 G43

12V 2000 G83

12V 2000 G43

900

500

3B

18V 2000 G83

16V 2000 G43

12V 2000 G43

16V 2000 G83

12V 2000 G83

3A

12V 2000 G83

16V 2000 G83

18V 2000 G83

16V 2000 G43

12V 2000 G43

Power Rating 60 Hz

Standby Prime Continuous

Page 6: MTU/DDC Stationary Power Generation Series 2000 · PDF filemonitoring and control integrated to the engine. ... MDEC Electonic System ... MTU/DDC Stationary Power Generation Series

607.10.2005DaimlerChrysler Off-Highway SGC - Binkle

MTU/DDC Stationary Power Generation Series 2000 EnginesNumber of delivered Series 2000 Engines for G-Drive Application(MTU + DDC)

0

2000

4000

6000

8000

10000

12000

1998 1999 2000 2001 2002 2003 2004

111

1261

3788

5633

6953

8664

11152[units]

Page 7: MTU/DDC Stationary Power Generation Series 2000 · PDF filemonitoring and control integrated to the engine. ... MDEC Electonic System ... MTU/DDC Stationary Power Generation Series

707.10.2005DaimlerChrysler Off-Highway SGC - Binkle

Closed Fuel System

• No fuel return line

• Only a vent line between the engine and fuel tank

• Very low increase of fuel temperature in the fuel tank

+ Easy installation

+ No need for fuel cooler

MTU/DDC Stationary Power Generation Series 2000 Engines – Technical Features

Page 8: MTU/DDC Stationary Power Generation Series 2000 · PDF filemonitoring and control integrated to the engine. ... MDEC Electonic System ... MTU/DDC Stationary Power Generation Series

807.10.2005DaimlerChrysler Off-Highway SGC - Binkle

Air-to-Air Charge Air Cooling

• Complete set with fan, radiator and pipe work

• Very compact design

+ Quick and simple installation

+ Less engineering+ Optimizes system+ Pre-designed Interface+ Radiator available for

different ambient temperatures

MTU/DDC Stationary Power Generation Series 2000 Engines – Technical Features

Page 9: MTU/DDC Stationary Power Generation Series 2000 · PDF filemonitoring and control integrated to the engine. ... MDEC Electonic System ... MTU/DDC Stationary Power Generation Series

907.10.2005DaimlerChrysler Off-Highway SGC - Binkle

Water-to-Air Charge Air Cooling

• SCCC dual cooling circuit

(Split circuit charge air cooling)

• With engine built heat exchanger (charge air Circuit)

• The option for remote cooling system

+ High flexibility in InstallationMechanic / electric driven radiator

Remote installed radiator / heat exchanger

MTU/DDC Stationary Power Generation Series 2000 Engines – Technical Features

Page 10: MTU/DDC Stationary Power Generation Series 2000 · PDF filemonitoring and control integrated to the engine. ... MDEC Electonic System ... MTU/DDC Stationary Power Generation Series

1007.10.2005DaimlerChrysler Off-Highway SGC - Binkle

Exhaust Gas System

• Two highly efficiency turbocharger

• Pulse charging• Short exhaust pipes

+ Optimum load acceptance

+ Vertical exhaust outlet+ Easy to connect to

external exhaust system

MTU/DDC Stationary Power Generation Series 2000 Engines – Technical Features

Page 11: MTU/DDC Stationary Power Generation Series 2000 · PDF filemonitoring and control integrated to the engine. ... MDEC Electonic System ... MTU/DDC Stationary Power Generation Series

1107.10.2005DaimlerChrysler Off-Highway SGC - Binkle

Electronic System for governing, monitoring and control integrated to the engine.+ Fully integrated engine mounted

System (ECU, Sensors, Wiring)

+ Easy to integrate to the genset controller

+ Flexibility (analog, digital, Can-Bus)

+ „plug and start“

MDEC Electonic System

MTU/DDC Stationary Power Generation Series 2000 Engines – Technical Features

Page 12: MTU/DDC Stationary Power Generation Series 2000 · PDF filemonitoring and control integrated to the engine. ... MDEC Electonic System ... MTU/DDC Stationary Power Generation Series

1207.10.2005DaimlerChrysler Off-Highway SGC - Binkle

MTU/DDC Stationary Power Generation Series 2000 Engines – Technical Features

Wide range of accessories available:• Various starting systems• Various fuel main and pre-filter• Oil interval pre-lubrication pumps• Exhaust gas bellows• Preheating systems• Engine resilient mounts• Peripheral interface modules

etc. - etc. – etc.+ Easy installation+ Original approved parts from one

supplier

Accessories

Page 13: MTU/DDC Stationary Power Generation Series 2000 · PDF filemonitoring and control integrated to the engine. ... MDEC Electonic System ... MTU/DDC Stationary Power Generation Series

1307.10.2005DaimlerChrysler Off-Highway SGC - Binkle

+ Constant power available up to 40 degC / 400 m

+ Low fuel consumption (Prime power 100% load only 194 g/kWh)

+ Fulfills Emission Standards

+ EPA for all 60 Hz ratings

+ TA-Luft for 50 Hz rating in 3B application

+ Japanese Standard

+ Excellent load acceptance

+ Load step >60 % recovery time < 2 sec

+ 100 % load acceptance according NFPA 110

Technical Benefits

MTU/DDC Stationary Power Generation Series 2000 Engines – Technical Features

Page 14: MTU/DDC Stationary Power Generation Series 2000 · PDF filemonitoring and control integrated to the engine. ... MDEC Electonic System ... MTU/DDC Stationary Power Generation Series

1407.10.2005DaimlerChrysler Off-Highway SGC - Binkle

MTU/DDC Stationary Power Generation Series 2000 Engines – Technical Documentation

1. Technical Sales Documentation S2000 – CD/MTU extranet

2. Installation guidelines engines/generator sets

3. Detailed price list with power rating overview, detailed ratings, scope of supply, options

4. Service documentation for each engine

Available Technical Documentation

DDC / MTU Diesel DDC / MTU Diesel EnginesEngines12V12V / / 16V16V / / 18V 200018V 2000 G23G23 –– G83G83

Stationary Stationary Power GenerationPower Generation

Deutsch / EnglishEdition: May 2005

Page 15: MTU/DDC Stationary Power Generation Series 2000 · PDF filemonitoring and control integrated to the engine. ... MDEC Electonic System ... MTU/DDC Stationary Power Generation Series

1507.10.2005DaimlerChrysler Off-Highway SGC - Binkle

MTU/DDC Stationary Power Generation Series 2000 Engines16V2000G63Continious Operation Indonesia

Page 16: MTU/DDC Stationary Power Generation Series 2000 · PDF filemonitoring and control integrated to the engine. ... MDEC Electonic System ... MTU/DDC Stationary Power Generation Series

1607.10.2005DaimlerChrysler Off-Highway SGC - Binkle

MTU/DDC Stationary Power Generation Series 2000 Engines

16V2000G63Container Gen SetItalia

Page 17: MTU/DDC Stationary Power Generation Series 2000 · PDF filemonitoring and control integrated to the engine. ... MDEC Electonic System ... MTU/DDC Stationary Power Generation Series

1707.10.2005DaimlerChrysler Off-Highway SGC - Binkle

MTU/DDC Stationary Power Generation Series 2000 Engines

Virtus Genset with 12V2000G63

Page 18: MTU/DDC Stationary Power Generation Series 2000 · PDF filemonitoring and control integrated to the engine. ... MDEC Electonic System ... MTU/DDC Stationary Power Generation Series

1807.10.2005DaimlerChrysler Off-Highway SGC - Binkle

DaimlerChrysler Off-HighwayWorldwide Sales Organization

AsiaMTU AsiaMTU Asia (China)MTU Asia (Thailand)MTU Engineering (Suzhou)MTU DD IndiaMTU DD IndonesiaMTU Japan14 Distributors20 Branches50 Dealers

NAFTAMTU Detroit Diesel29 Distributors

160 Branches416 Dealers

Latin AmericaMTU do Brasil18 Distributors21 Branches12 Dealers

AfricaMTU South Africa10 Distributors15 Branches20 Dealers

Near-/Middle East17 Distributors21 Branches10 Dealers

EuropeMTU FNMTU FranceMTU ItalyMTU TurkeyMTU DD UKMTU DD Benelux25 Distributors30 Branches

130 Dealers

Australia/PacificMTU DD Australia

3 Distributors22 Branches31 Dealers

Worldwide 1100 Points of Contact with 130 Distributors in 130 Countries for Sales & Service

RegionalCenter 3

RegionalCenter 4

RegionalCenter 1

RegionalCenter 2

Friedrichshafen

Singapore

Detroit

Page 19: MTU/DDC Stationary Power Generation Series 2000 · PDF filemonitoring and control integrated to the engine. ... MDEC Electonic System ... MTU/DDC Stationary Power Generation Series

Thank you for your attention

Page 20: MTU/DDC Stationary Power Generation Series 2000 · PDF filemonitoring and control integrated to the engine. ... MDEC Electonic System ... MTU/DDC Stationary Power Generation Series

2007.10.2005DaimlerChrysler Off-Highway SGC - Binkle

MTU/DDC Stationary Power Generation Series 2000 Engines – Technical Services

• Torsional vibration calculation

• Noise calculations

• Calculation of pipe works – air intake / exhaust / coolant / fuel

• Load acceptance calculations

• Installation checks

• Life cycle cost analysis

Available Technical Services

Page 21: MTU/DDC Stationary Power Generation Series 2000 · PDF filemonitoring and control integrated to the engine. ... MDEC Electonic System ... MTU/DDC Stationary Power Generation Series

2107.10.2005DaimlerChrysler Off-Highway SGC - Binkle

DaimlerChrysler Off-HighwayProduct Support & Services

Tools and Spare Parts- ServiceParts Inventory Recommendations

Tools and Spare Parts- ServiceParts Inventory Recommendations

Technical Product SupportMaintenance Personnel

Technical Product SupportMaintenance Personnel

Customer Training

Customer Training

Technical PublicationsInformation ServiceConfiguration Management

Technical PublicationsInformation ServiceConfiguration Management

Factory OverhaulModernizations

Factory OverhaulModernizations

Analysis of Reliability, Availability, Maintainability, Safety (RAMS) and LCC

Analysis of Reliability, Availability, Maintainability, Safety (RAMS) and LCC

Workshop Planning, TestbenchInstallation, Turn-key plantsEngine Data Management

Workshop Planning, TestbenchInstallation, Turn-key plantsEngine Data Management

Service ConceptsMaintenance Contracts

Service ConceptsMaintenance Contracts


Recommended