152
Transcript
Page 1: MTW.pdf · ERCP-catheter, reusable All ERCP-catheters with mandrin, and nozzle for injection of contrast medium suitable for guide wire ERCP-catheter,
Page 2: MTW.pdf · ERCP-catheter, reusable All ERCP-catheters with mandrin, and nozzle for injection of contrast medium suitable for guide wire ERCP-catheter,

Papillotomes

ERCP-catheters

Endoprostheses &PTC-needles

Bronchoscope-instruments

Accessories

Sclerosing-needles &Needles forfibrinadhesive-injection

Cytology- andCleaning-brushes

Foreign-bodyremoving forceps

Polypectomy snares

Lithotomy baskets &stone-extraction-balloonsLithotriptors

1

2

3

4

5

6

7

8

9

11

10

Guide wires 12

Postbox 14 01 18 • D-46476 WeselGoldsbergstraße 18 • D-46487 WeselPhone +49 28 03/91 20-0Fax +49 28 03/81 13

www.mtw-endoskopie.dee-mail: [email protected]

Biopsy-forcepsRectoscopy-forceps &shaft

For all products specified in this catalogwe reserve ourselves technical changesand picture deviations.

Page 3: MTW.pdf · ERCP-catheter, reusable All ERCP-catheters with mandrin, and nozzle for injection of contrast medium suitable for guide wire ERCP-catheter,

2

134 0C

Instruments showing this symbol are autoclavable: 5 minutes with 134°C (273°F), 2 bar or20 minutes with 121°C (246°F), 1 bar

Instruments showing this symbol can be sterilized via ETOgas sterilisation or similar (they cannot be autoclaved).

Instruments showing this symbol are disposable productsto be used one time only.

Polypectomy snares showing this symbol do have an isolated distal tip.

Polypectomy snares showing this symbol are rotatable.

0.035

0.025

Papillotomes showing this symbol align themselves after11 o’clock.

Instruments showing this symbol are suitable for 0.035 inch guide wires.

Instruments showing this symbol are suitable for 0.018 inch guidewires.

Instruments showing these symbols are multi lumen.

Instruments showing this symbol do have a nozzle on the side to wash-out.

Instruments showing this symbol are suitable for 0.025 inch guide wires.

0.018

Reference symbols

Papillotomes showing this symbol align themselves after12 o’clock.

Instruments showing this symbol are radiopaque.

Page 4: MTW.pdf · ERCP-catheter, reusable All ERCP-catheters with mandrin, and nozzle for injection of contrast medium suitable for guide wire ERCP-catheter,

ERCP-catheters

Endoscopic instrumentsand accessories

1

Page 5: MTW.pdf · ERCP-catheter, reusable All ERCP-catheters with mandrin, and nozzle for injection of contrast medium suitable for guide wire ERCP-catheter,

1

Aus

gabe

2-0

4.04

nozzle for injection ofcontrast medium

Article-no.

ERCP-catheter, reusable

All ERCP-catheters with mandrin,and nozzle for injection of contrast mediumsuitable for guide wire

ERCP-catheter, standard

Length (cm)

Guidewire (inch)

ERCP-catheter, filiform Length (cm)

Guidewire (inch)

Article-no.

01 20 10 0 1,6 215 0.025

01 20 10 1 2,3 > 1,6 215 0.025

01 30 10 0 1,8 215 0.035

01 30 10 1 2,3 > 1,8 215 0.035

01 30 90 0 2,3 215 0.035

01 20 20 0 1,6 215 0.025

01 20 20 1 2,3 > 1,6 215 0.025

01 30 20 0 1,8 215 0.035

01 30 20 1 2,3 > 1,8 215 0.035

01 31 00 0 2,3 215 0.035

Description

Description

0.025 0.035

for 0.025 inchguide wire

for 0.035 inchguide wire

guide wire arrestable withintegrated mandrin

guide wire arrestable withintegrated mandrin

guide wire arrestable withintegrated mandrin

guide wire arrestable withintegrated mandrin

Diameter (mm)

Diameter (mm)

Page 6: MTW.pdf · ERCP-catheter, reusable All ERCP-catheters with mandrin, and nozzle for injection of contrast medium suitable for guide wire ERCP-catheter,

2

ERCP-catheter, reusable

All ERCP-catheters with mandrin,and nozzle for injection of contrast mediumsuitable for guide wire

ERCP-catheter, conical tip

Description Length (cm)

Guide wire(inch)

ERCP-catheter, filiform, radiopaque, with metal ring inside

Length (cm)

Guide wire(inch)

Description

Article-no.

Article-no.

nozzle for injection ofcontrast medium

01 20 70 0 1,6 215 0.025

01 20 70 1 2,3 > 1,6 215 0.025

01 30 70 0 1,8 215 0.035

01 30 70 1 2,3 > 1,8 215 0.035

01 20 21 0 1,6 215 0.025

01 20 21 1 2,3 > 1,6 215 0.025

01 30 21 0 1,8 215 0.035

01 30 21 1 2,3 > 1,8 215 0.035

guide wire arrestable withintegrated mandrin

guide wire arrestable withintegrated mandrin

guide wire arrestable withintegrated mandrin

guide wire arrestable withintegrated mandrin

Diameter (mm)

Diameter (mm)

0.035

for 0.035 inchguide wire

0.025

for 0.025 inchguide wire

Page 7: MTW.pdf · ERCP-catheter, reusable All ERCP-catheters with mandrin, and nozzle for injection of contrast medium suitable for guide wire ERCP-catheter,

3

Aus

gabe

2-0

4.04

ERCP-catheter, reusable

All ERCP-catheters with mandrin,and nozzle for injection of contrast mediumsuitable for guide wire

ERCP-catheter, standard, radiopaque, with metal ring inside

Length (cm)

Guide wire(inch)

Description

nozzle for injection ofcontrast medium

Article-no.

ERCP-catheter with thin metal cannula

01 01 11 0 1,6 215 — Ø cannula = 0,7

Description Length (cm)

Guide wire(inch)

Article-no.

0.025 0.035

for 0.025 inchguide wire

for 0.035 inchguide wire

Ø 0,7

3

01 20 11 0 1,6 215 0.025

01 21 11 0 2,3 > 1,6 215 0.025

01 30 11 0 1,8 215 0.035

01 31 11 0 2,3 > 1,8 215 0.035

guide wire arrestable withintegrated mandrin

guide wire arrestable withintegrated mandrin

Diameter (mm)

Diameter (mm)

Page 8: MTW.pdf · ERCP-catheter, reusable All ERCP-catheters with mandrin, and nozzle for injection of contrast medium suitable for guide wire ERCP-catheter,
Page 9: MTW.pdf · ERCP-catheter, reusable All ERCP-catheters with mandrin, and nozzle for injection of contrast medium suitable for guide wire ERCP-catheter,

5

Aus

gabe

2-0

4.04

ERCP-catheter, reusable

ERCP-catheter, with round metal tip

Length (cm)

Guide wire(inch)

DescriptionArticle-no.

01 20 31 0 1,6 215 0.025

01 20 31 1 2,3 > 1,6 215 0.025

01 30 31 0 1,8 215 0.035

01 30 31 1 2,3 > 1,8 215 0.035

0.035

for 0.035 inchguide wire

nozzle for injection ofcontrast medium

0.025

for 0.025 inchguide wire

All ERCP-catheters with mandrin,and nozzle for injection of contrast mediumsuitable for guide wire

guide wire arrestable withintegrated mandrin

guide wire arrestable withintegrated mandrin

Diameter (mm)

x

5

Article-no. X Diameter (mm) (mm)

ERCP-catheter with thin metal cannula

DescriptionLength(cm)

Guide wire(inch)

01 01 02 0 1,0 2,3 > 1,6 215 0.018

01 02 02 0 1,3 2,3 > 1,6 215 0.025

01 03 02 0 1,6 2,3 > 1,8 215 0.035

guide wire arrestable withintegrated mandrin

0.018

for 0.018 inchguide wire

Page 10: MTW.pdf · ERCP-catheter, reusable All ERCP-catheters with mandrin, and nozzle for injection of contrast medium suitable for guide wire ERCP-catheter,

6

ERCP-catheter, reusable

All ERCP-catheters with mandrin,and nozzle for injection of contrast mediumsuitable for guide wire

ERCP-catheter, with bottle-top shaped metal tip

Length (cm)

Guide wire(inch)

Article-no.

01 20 51 0 1,6 215 0.025

01 20 51 1 2,3 > 1,6 215 0.025

01 30 51 0 1,8 215 0.035

01 30 51 1 2,3 > 1,8 215 0.035

Description

nozzle for injection ofcontrast medium

0.025

for 0.025 inchguide wire

guide wire arrestablewith integrated mandrin

guide wire arrestablewith integrated mandrin

Diameter (mm)

ERCP-catheter, with filiform metal tip

Length (cm)

Guide wire(inch)

DescriptionArticle-no.

01 20 41 0 1,6 215 0.025

01 20 41 1 2,3 > 1,6 215 0.025

01 30 41 0 1,8 215 0.035

01 30 41 1 2,3 > 1,8 215 0.035

guide wire arrestable withintegrated mandrin

guide wire arrestable withintegrated mandrin

Diameter (mm)

0.035

for 0.035 inchguide wire

Page 11: MTW.pdf · ERCP-catheter, reusable All ERCP-catheters with mandrin, and nozzle for injection of contrast medium suitable for guide wire ERCP-catheter,

7

Aus

gabe

2-0

4.04

ERCP-catheter, reusable

ERCP-catheter, multi lumen, radiopaque tip

0.035

for 0.035 inchguide wire

nozzle for injection ofcontrast medium

Description Length (cm)

Guide wire(inch)

Article-no.

All ERCP-catheters with mandrin,and nozzle for injection of contrast mediumsuitable for guide wire

01 30 12 1 2,3 > 1,8 215 0.035

01 30 42 1 2,5 > 2,0 215 0.035

Length (cm)

Guide wire(inch)

ERCP-catheter, with conical metal tip

Article-no.

01 20 61 0 1,6 215 0.025

01 20 61 1 2,3 > 1,6 215 0.025

01 30 61 0 1,8 215 0.035

01 30 61 1 2,3 > 1,8 215 0.035

Description

0.025

for 0.025 inchguide wire

guide wire arrestablewith integrated mandrin

guide wire arrestablewith integrated mandrin

guide wire arrestablewith integrated mandrin

guide wire arrestablewith integrated mandrin

Diameter (mm)

Diameter (mm)

Page 12: MTW.pdf · ERCP-catheter, reusable All ERCP-catheters with mandrin, and nozzle for injection of contrast medium suitable for guide wire ERCP-catheter,

8

Wash-out- & spraycatheter, reusable

Description Length (cm)

Spraycatheter

11 01 01 21 0 1,8 120

11 01 01 31 0 2,3 120

01 01 21 4 1,8 160

01 01 31 4 2,3 160

01 01 21 5 1,8 180

01 01 31 5 2,3 180

01 01 21 0 1,8 230

01 01 31 0 2,3 230

Article-no.

Wash-out catheter, round metal tip

Length (cm)

Description

01 31 21 0 2,3 215

Article-no.

nozzle for injection ofcontrast medium

Diameter (mm)

Diameter (mm)

for spraying on marking fluidfor a better distinguishing ofpathological structures

Page 13: MTW.pdf · ERCP-catheter, reusable All ERCP-catheters with mandrin, and nozzle for injection of contrast medium suitable for guide wire ERCP-catheter,

9

Aus

gabe

2-0

4.04

0.035

for 0.035 inchguide wire

ERCP-catheter, disposable

ERCP-catheter, standard

DescriptionGuide wire(inch)

99 01 30 10 0 1,8 215 0.035

ERCP-catheter, filiform

Length (cm)

Guide wire(inch)

Description

nozzle for injection ofcontrast medium

All disposable ERCP-catheters are delivered in packaging units.

Length (cm)

Article-no.

Article-no.

All ERCP-catheters with mandrin,and nozzle for injection of contrast mediumsuitable for guide wire

99 01 30 20 0 1,8 215 0.035

2

Diameter (mm)

Diameter (mm)

Packagingunit: 5 pieces

Packagingunit: 5 pieces

Page 14: MTW.pdf · ERCP-catheter, reusable All ERCP-catheters with mandrin, and nozzle for injection of contrast medium suitable for guide wire ERCP-catheter,

10

ERCP-catheter, disposable

All ERCP-catheters with mandrin,and nozzle for injection of contrast mediumsuitable for guide wire

ERCP-catheter, standard

ERCP-catheter, filiform

Length(cm)

Guide wire(inch)

Description

2

All disposable ERCP-catheters are delivered in packaging units.

Article-no.

Length(cm)

Guide wire(inch)

Description

99 01 30 10 3 2,3 > 1,8 215 0.035

Article-no.

99 01 30 20 3 2,3 > 1,8 215 0.035

nozzle for injection ofcontrast medium

0.035

for 0.035 inchguide wire

DISPOSABLE

arrestable

Diameter (mm)

Diameter (mm)

guide wire arrestable

Packagingunit: 5 pieces

guide wire arrestable

Packagingunit: 5 pieces

To be used with lying guide wire, arrestable

Page 15: MTW.pdf · ERCP-catheter, reusable All ERCP-catheters with mandrin, and nozzle for injection of contrast medium suitable for guide wire ERCP-catheter,

11

Aus

gabe

2-0

4.04

ERCP-catheter, disposable

ERCP-catheter, standard

DescriptionGuide wire(inch)

99 01 30 10 1 2,3 > 1,8 215

ERCP-catheter, filiform

Length(cm)

Guide wire(inch)

Description

All disposable ERCP-catheters are delivered in packaging units.

To be used with lying guide wire, arrestable

Length(cm)

Article-no.

Article-no.

All ERCP-catheters with mandrin,and nozzle for injection of contrast mediumsuitable for guide wire

99 01 30 20 1 2,3 > 1,8 215

2

Diameter (mm)

Diameter (mm)

guide wire arrestable withintegrated mandrin

Packagingunit: 5 pieces

guide wire arrestable withintegrated mandrin

Packagingunit: 5 pieces

0.035

for 0.035 inchguide wire

nozzle for injection ofcontrast medium

0.025

for 0.025 inchguide wire

guide wire

arrestable

Page 16: MTW.pdf · ERCP-catheter, reusable All ERCP-catheters with mandrin, and nozzle for injection of contrast medium suitable for guide wire ERCP-catheter,

12

ERCP-catheter, disposable

All ERCP-catheters with mandrin,and nozzle for injection of contrast mediumsuitable for guide wire

DescriptionLength (cm)

Guide wire(inch)

ERCP-catheter, round metal tip

99 01 30 31 0 1,8 215 0.035

ERCP-catheter, bottle-top shaped metal tip

Description Length (cm)

Guide wire(inch)

2

All disposable ERCP-catheters are delivered in packaging units.

99 01 20 51 0 1,6 215 0.025

99 01 30 51 0 1,8 215 0.035

Article-no.

Article-no.

0.035

for 0.035 inchguide wire

nozzle for injection ofcontrast medium

Diameter (mm)

Diameter (mm)

Packagingunit: 5 pieces

Packagingunit: 5 piecesPackagingunit: 5 pieces

Packagingunit: 5 pieces

Page 17: MTW.pdf · ERCP-catheter, reusable All ERCP-catheters with mandrin, and nozzle for injection of contrast medium suitable for guide wire ERCP-catheter,

13

Aus

gabe

2-0

4.04

ERCP-catheter, disposable

All ERCP-catheters with mandrin,and nozzle for injection of contrast mediumsuitable for guide wire

DescriptionLength(cm)

Guide wire(inch)

ERCP-catheter, round metal tip

99 01 30 31 3 2,3 > 1,8 215 0.035

ERCP-catheter, bottle-top shaped metal tip

Description Length (cm)

Guide wire(inch)

2

All disposable ERCP-catheters are delivered in packaging units.

To be used with lying guide wire, arrestable

99 01 30 51 3 2,3 > 1,8 215 0.035

Article-no.

Article-no.

0.035

for 0.035 inchguide wire

nozzle for injection ofcontrast medium

guide wire arrestable

DISPOSABLE

arrestable

Diameter (mm)

Diameter (mm)

Packaging unit:5 pieces

guide wire arrestable

Packaging unit:5 pieces

Page 18: MTW.pdf · ERCP-catheter, reusable All ERCP-catheters with mandrin, and nozzle for injection of contrast medium suitable for guide wire ERCP-catheter,

14

ERCP-catheter, disposable

All ERCP-catheters with mandrin,and nozzle for injection of contrast mediumsuitable for guide wire

DescriptionLength(cm)

Guide wire(inch)

ERCP-catheter, round metal tip

99 01 30 31 1 2,3 > 1,8 215

ERCP-catheter, bottle-top shaped metal tip

DescriptionLength(cm)

Guide wire(inch)

2

All disposable ERCP-catheters are delivered in packaging units.

To be used with lying guide wire, arrestable

99 01 30 51 1 2,3 > 1,8 215

Article-no.

Article-no.

for 0.035 inchguide wire

Diameter(mm)

Diameter(mm)

for 0.025 inchguide wire

0.025 0.035

nozzle for injection ofcontrast medium

guide wire

arrestable

guide wire arrestable withintegrated mandrin

guide wire arrestable withintegrated mandrin

Packaging unit:5 pieces

Packaging unit:5 pieces

Page 19: MTW.pdf · ERCP-catheter, reusable All ERCP-catheters with mandrin, and nozzle for injection of contrast medium suitable for guide wire ERCP-catheter,

Papillotomes

Endoscopic instrumentsand accessories

2

Page 20: MTW.pdf · ERCP-catheter, reusable All ERCP-catheters with mandrin, and nozzle for injection of contrast medium suitable for guide wire ERCP-catheter,

1

Aus

gabe

2-0

4.04

Article-no. X Diameter (mm) (mm)

Papillotomes, reusable

These papillotomes have a pre-assembled handle,are radiopaque and autoclavable.

Precut-papillotome

DescriptionLength(cm)

Guide wire(inch)

Papillotome, standard, 5 mm tip

Article-no. X Diameter (mm) (mm)

02 50 31 15 1,6 215 —

02 60 31 20 1,6 215 —

02 00 31 30 1,6 215 —

x

5

x

Guide wire(inch)

Description

Handle with nozzle for injectionof contrast medium

02 50 11 15 1,6 215 —

02 00 11 20 1,6 215 —

02 00 21 30 1,6 215 —

Length(cm)

Stopper for handle:see chapter 10,page 9

Page 21: MTW.pdf · ERCP-catheter, reusable All ERCP-catheters with mandrin, and nozzle for injection of contrast medium suitable for guide wire ERCP-catheter,

2

Article-no. X Diameter (mm) (mm)

Papillotomes, filiform, reusable

These papillotomes have a pre-assembled handle,are radiopaque and autoclavable.

Papillotome, filiform

DescriptionGuide wire(inch)

02 00 53 15 1,6 215 —

02 00 54 20 1,6 215 —

02 00 51 30 1,6 215 —

02 00 71 30 1,6 215 —

Papillotome, filiform

Article-no. X Diameter (mm) (mm)

Guide wire(inch)

02 05 51 30 1,6 215 —

Description

7

xx

Handle with nozzle for injectionof contrast medium

radiopaque tip,type "a"

strengthened and

radiopaque tip

for Papilla Minor,with cutting metaltip, type "b“

2,5

x

„a“

„b“

Length(cm)

Length(cm)

Stopper for handle:see chapter 10,page 9

Page 22: MTW.pdf · ERCP-catheter, reusable All ERCP-catheters with mandrin, and nozzle for injection of contrast medium suitable for guide wire ERCP-catheter,

3

Aus

gabe

2-0

4.04

Article-no. X Diameter (mm) (mm)

Papillotomes, reusable

These papillotomes have a pre-assembled handle,are radiopaque and autoclavable.

Papillotome, filiform

Handle with nozzle for injectionof contrast medium

DescriptionGuide wire(inch)

02 45 51 30 1,6 215 —

Papillotome

Article-no. X Diameter (mm) (mm)

Guide wire(inch)

02 00 61 30 1,6 215 —

Description

15

x

with metal tipand guiding tip,siliconstrengthened

7

x

strengthenedwithflat feather

Length(cm)

Length(cm)

Stopper for handle:see chapter 10,page 9

Page 23: MTW.pdf · ERCP-catheter, reusable All ERCP-catheters with mandrin, and nozzle for injection of contrast medium suitable for guide wire ERCP-catheter,
Page 24: MTW.pdf · ERCP-catheter, reusable All ERCP-catheters with mandrin, and nozzle for injection of contrast medium suitable for guide wire ERCP-catheter,

5

Aus

gabe

2-0

4.04

Article-no. X Diameter (mm) (mm)

Papillotomes, cutting direction "left", reusable

These papillotomes have a pre-assembled handle,are radiopaque and autoclavable.

Attention: All papillotomes for guide wires are only usablewith insulated guide wires!

Papillotome, filiform, flat feather, for guide wire

DescriptionGuide wire(inch)

Papillotome with metal tip, flat feather

Article-no. X Diameter (mm) (mm)

Guide wire(inch)

Description

7

x

15

x

Handle with nozzle for injectionof contrast medium

Handle with nozzle for injectionof contrast medium. To be used with lying guide wire.

02 40 51 30 1,6 215 —

02 37 51 30 2,3 > 1,8 215 0.035

with flatfeatherwith flatfeather

02 40 61 30 1,6 215 — with guiding tip,metal tip and flatfeather, rotated

0.035

for guide wire0.035 inch

Length(cm)

Length(cm)

Fitting guide wires: see chapter 12!

Stopper for handle:see chapter 10,page 9

Page 25: MTW.pdf · ERCP-catheter, reusable All ERCP-catheters with mandrin, and nozzle for injection of contrast medium suitable for guide wire ERCP-catheter,

6

Article-no. X Diameter (mm) (mm)

Papillotomes, reusable

These papillotomes have a pre-assembled handle,are radiopaque and autoclavable.

Combined papillotome, needle retractable

DescriptionGuide wire(inch)

02 01 01 30 1,6 215 — strengthened

Knife-papillotome

Article-no. X Diameter (mm) (mm)

Guide wire(inch)

02 01 31 10 1,6 215 —

Description

x

10

Handle with nozzle for injectionof contrast medium

x

Length(cm)

Length(cm)

Stopper for handle:see chapter 10,page 9

Page 26: MTW.pdf · ERCP-catheter, reusable All ERCP-catheters with mandrin, and nozzle for injection of contrast medium suitable for guide wire ERCP-catheter,

7

Aus

gabe

2-0

4.04

Article-no. X Diameter (mm) (mm)

Needle-papillotomes, reusable

These papillotomes have a pre-assembled handle,are radiopaque and autoclavable.

Needle-papillotome, Iso-Tome

DescriptionGuide wire(inch)

02 01 21 6 1,6 215 —

Needle-papillotome, injection through the cannula

Article-no. X Diameter (mm) (mm)

Guide wire(inch)

02 01 11 6 2,3 215 —

Description Ø 1

Handle with nozzle for injectionof contrast medium

x

x

Length(cm)

Lenght(cm)

Stopper for handle:see chapter 10,page 9

Page 27: MTW.pdf · ERCP-catheter, reusable All ERCP-catheters with mandrin, and nozzle for injection of contrast medium suitable for guide wire ERCP-catheter,

Aus

gabe

2-0

4.04

Article-no. X Diameter (mm) (mm)

Papillotomes B-II-stomach, reusable

These papillotomes have a pre-assembled handle,are radiopaque and autoclavable.

Attention: All papillotomes for guide wires are only usablewith insulated guide wires!

Papillotome B-II-stomach

DescriptionGuide wire(inch)

02 01 51 20 1,8 215 —

02 01 61 20 2,3 215 —

02 01 71 20 2,3 215 —

only rotatable incombination with theuniversal handle 10 30 0

Papillotome B-II-stomach, for guide wire

Article-no. X Diameter (mm) (mm)

Guide wire(inch)

Description

x

x

0.025 0.035

for guide wire0.025 inch

for guide wire0.035 inch

02 21 61 20 2,3 215 0.025

02 31 61 20 2,3 215 0.035

rotatable

Length(cm)

Length(cm)

Fitting guide wires: see chapter 12!

Handle with nozzle for injection of contrast medium.To be used with lying guide wire.

Stopper forhandle: seechapter 10,page 9

Page 28: MTW.pdf · ERCP-catheter, reusable All ERCP-catheters with mandrin, and nozzle for injection of contrast medium suitable for guide wire ERCP-catheter,

Article-no. X Diameter (mm) (mm)

Papillotomes for guide wire, reusable

These papillotomes have a pre-assembled handle,are radiopaque and autoclavable.

Attention: All papillotomes for guide wires are only usablewith insulated guide wires!

Precut-papillotome

DescriptionGuide wire(inch)

Papillotome, standard, 5 mm guiding tip

Article-no. X Diameter (mm) (mm)

Guide wire(inch)

Description

0.0250.035

for guide wire0.025 inch

for guide wire0.035 inch

02 20 11 20 2,3 > 1,6 215 0.025

02 30 11 20 2,3 > 1,8 215 0.035

02 20 21 30 2,3 > 1,6 215 0.025

02 30 21 30 2,3 > 1,8 215 0.035

02 20 33 15 2,3 > 1,6 215 0.025

02 30 33 15 2,3 > 1,8 215 0.035

02 20 34 20 2,3 > 1,6 215 0.025

02 30 34 20 2,3 > 1,8 215 0.035

02 20 31 30 2,3 > 1,6 215 0.025

02 30 31 30 2,3 > 1,8 215 0.035

Length(cm)

Length(cm)

Fitting guide wires: see chapter 12!

x5

x

Handle with nozzle for injection of contrast medium.To be used with lying guide wire.

Stopper forhandle: seechapter 10,page 9

Page 29: MTW.pdf · ERCP-catheter, reusable All ERCP-catheters with mandrin, and nozzle for injection of contrast medium suitable for guide wire ERCP-catheter,

1

Aus

gabe

2-0

4.04

Article-no. X Diameter (mm) (mm)

Papillotomes for guide wire, reusable

These papillotomes have a pre-assmebled handle,are radiopaque, autoclavable and can be introduced with a guide wire.Attention: All papillotomes for guide wires are only usablewith insulated guide wires!

0.025 0.035

for guide wire0.025 inch

for guide wire0.035 inch

Papillotome, filiform

DescriptionGuide wire(inch)

Papillotome with metal tip

7

X

Article-no. X Diameter (mm) (mm)

Guide wire(inch)

Description

15

x

Handle with nozzle for injection of contrast medium.To be used with lying guide wire.

02 20 53 15 2,3 > 1,6 215 0.025

02 30 53 15 2,3 > 1,8 215 0.035

02 20 54 20 2,3 > 1,6 215 0.025

02 36 51 20 2,3 > 1,8 215 0.035

02 20 51 30 2,3 > 1,6 215 0.025

02 30 51 30 2,3 > 1,8 215 0.035

02 20 61 30 2,3 > 1,6 215 0.025

02 30 61 30 2,3 > 1,8 215 0.035

Length(cm)

Length(cm)

Fitting guide wires: see chapter 12!

Stopper forhandle: seechapter 10,page 9

Page 30: MTW.pdf · ERCP-catheter, reusable All ERCP-catheters with mandrin, and nozzle for injection of contrast medium suitable for guide wire ERCP-catheter,
Page 31: MTW.pdf · ERCP-catheter, reusable All ERCP-catheters with mandrin, and nozzle for injection of contrast medium suitable for guide wire ERCP-catheter,

Article-no. X Diameter (mm) (mm)

Papillotomes for guide wires, reusable

These papillotomes have a pre-assembled handle,are radiopaque, autoclavable and can be introduced with a guide wire.Attention: All papillotomes for guide wires are only usablewith insulated guide wires!

Precut-papillotome, multi lumen

DescriptionGuide wire(inch)

02 32 71 20 2,3 > 1,8 215 0.035

02 34 71 20 2,5 > 2,0 215 0.035

Papillotome, standard, multi lumen

Article-no. X Diameter (mm) (mm)

Guide wire(inch)

02 32 61 20 2,3 > 1,8 215 0.035

02 32 41 30 2,3 > 1,8 215 0.035

02 34 61 20 2,5 > 2,0 215 0.035

02 34 41 30 2,5 > 2,0 215 0.035

Description

0.035

for guide wire0.035 inch

Handle with nozzle for injection of contrast medium.To be used with lying guide wire.

multi-lumen

Length(cm)

Length(cm)

Fitting guide wires: see chapter12!

x5

x

Stopper forhandle: seechapter 10,page 9

Page 32: MTW.pdf · ERCP-catheter, reusable All ERCP-catheters with mandrin, and nozzle for injection of contrast medium suitable for guide wire ERCP-catheter,

Aus

gabe

2-0

4.04

Article-no. X Diameter (mm) (mm)

Papillotomes, disposable

These papillotomes have a pre-assembled handleand are radiopaque.

Precut-papillotome

Guide wire(inch)

99 02 00 11 20 1,6 215 —

Papillotome, filiform

Article-no. X Diameter (mm) (mm)

Guide wire(inch)

99 02 00 51 30 1,6 215 —

Description

2

X

All disposable papillotomes are delivered in packaging units.

7

X

Description

Handle with nozzle for injection of contrastmedium

SPOSABLE

Length(cm)

Length(cm)

Packaging unit:5 pieces

Packaging unit:5 pieces

Stopper forhandle: seechapter 10,page 9

Page 33: MTW.pdf · ERCP-catheter, reusable All ERCP-catheters with mandrin, and nozzle for injection of contrast medium suitable for guide wire ERCP-catheter,

Article-no. X Diameter (mm) (mm)

Papillotomes, disposable

These papillotomes have a pre-assembled handleand are radiopaque.

Needle-papillotome

DescriptionGuide wire(inch)

99 02 01 21 — 1,6 215 —

Length(cm)

All disposable papillotomes are delivered in packaging units.

Packaging unit:5 pieces

2

6

Handle with nozzle for injection of contrastmedium

SPOSABLE

Stopper for handle:see chapter 10,page 9

Page 34: MTW.pdf · ERCP-catheter, reusable All ERCP-catheters with mandrin, and nozzle for injection of contrast medium suitable for guide wire ERCP-catheter,

Aus

gabe

2-0

4.04

Article-no. X Diameter (mm) (mm)

Papillotomes for guide wire, disposable

These papillotomes have a pre-assembled handle, are radiopaque,and can be introduced with a guide wire

Attention: All papillotomes for guide wires are only usablewith insulated guide wires!

Precut-papillotome

DescriptionGuide wire( inch)

99 02 30 11 20 2,3 > 1,8 215 0.035

Papillotome, standard

Guide wire(inch)

99 02 30 31 30 2,3 > 1,8 215 0.035

Description

All disposable papillotomes are delivered in packaging units.

0.035

for guide wire0.035 inch

DISPOSABLE

Length(cm)

Article-no. X Diameter (mm) (mm)

Length(cm)

Fitting guide wires: see chapter 12!

Packaging unit:5 pieces

Packaging unit:5 pieces

2x

5

x

Stopper for handle:see chapter 10,page 9

Page 35: MTW.pdf · ERCP-catheter, reusable All ERCP-catheters with mandrin, and nozzle for injection of contrast medium suitable for guide wire ERCP-catheter,

1

Papillotomes for guide wire, disposable

These papillotomes have a pre-assembled handle, radiopaqueand can be introduced with a guide wire

Attention: All papillotomes for guide wires are only usablewith insulated guide wires!

Papillotome, filiform

DescriptionGuide wire(inch)

99 02 30 51 30 2,3 > 1,8 215 0.035

99 02 36 51 20 2,3 > 1,8 215 0.035

2

All disposable papillotomes are delivered in packaging units.

7

x

0.035

for guide wire0.035 inch

DISPOSABLE

Length(cm)

Article-no. X Diameter (mm) (mm)

Fitting guide wires: see chapter 12!

Packaging unit:5 piecesPackaging unit:5 pieces

Stopper for handle:see chapter 10,page 9

Page 36: MTW.pdf · ERCP-catheter, reusable All ERCP-catheters with mandrin, and nozzle for injection of contrast medium suitable for guide wire ERCP-catheter,

1

Aus

gabe

2-0

4.04

Papillotomes "Hyperline", disposable

Article-no. X Diameter (mm) (mm)

These papillotomes have a pre-assembled handle,are two-lumen and are appropiate for guide wire.

Attention: All papillotomes for guide wires are only usablewith insulated guide wires!

Papillotome, standard, multi lumen

DescriptionGuide wire(inch)

Precut-papillotome, multi lumen

Article-no. X Diameter (mm) (mm)

Guide wire(inch)

99 02 32 61 20 2,3 > 1,8 215 0.035

99 02 32 41 30 2,3 > 1,8 215 0.035

99 02 34 61 20 2,5 > 2,0 215 0.035

99 02 34 41 30 2,5 > 2,0 215 0.035

Description

2

5

20

Handle with nozzle for injection of contrast medium.To be used with lying guide wire.

Length(cm)

Length(cm)

Fitting guide wires: see chapter 12!

Packaging unit:5 pieces

Packaging unit:5 pieces

Packaging unit:5 pieces

0.035

für Führungsdraht0.035 inch

Stopper forhandle: seechapter 10,page 9

multi-lumen

Packaging unit:5 pieces

99 02 32 71 20 2,3 > 1,8 215 0.035

99 02 34 71 20 2,5 > 2,0 215 0.035

Page 37: MTW.pdf · ERCP-catheter, reusable All ERCP-catheters with mandrin, and nozzle for injection of contrast medium suitable for guide wire ERCP-catheter,

Lithotomy baskets& stone-extraction-

balloonsLithotriptors

Endoscopic instrumentsand accessories

3

Page 38: MTW.pdf · ERCP-catheter, reusable All ERCP-catheters with mandrin, and nozzle for injection of contrast medium suitable for guide wire ERCP-catheter,

1

Aus

gabe

2-0

4.04

Symbol key of chapter 3

Lithotomy baskets characterizedwith this symbol, are suitable forlithotripsy

Products with this symbol enablethe lithotripsy through theendoscope

Page 39: MTW.pdf · ERCP-catheter, reusable All ERCP-catheters with mandrin, and nozzle for injection of contrast medium suitable for guide wire ERCP-catheter,

2

Article-no. X/Y Diameter (mm) (mm)

Lithotomy baskets, reusable

With a nozzle on the side for injectionof contrast medium

Lithotomy basket, twisted wires

Description

y

x03 11 21 04 10/20 1,8 215

03 11 23 04 15/25 1,8 215

03 11 24 04 20/30 1,8 215

03 11 25 04 25/40 1,8 215

03 11 26 04 30/45 1,8 215

03 11 27 04 40/55 1,8 215

03 11 28 04 45/60 1,8 215

03 11 31 04 10/20 2,3 215

03 11 33 04 15/25 2,3 215

03 11 34 04 20/30 2,3 215

03 11 35 04 25/40 2,3 215

03 11 36 04 30/45 2,3 215

03 11 37 04 40/55 2,3 215

03 11 38 04 45/60 2,3 215

Handle with nozzle for injectionof contrast medium

suitable forlithotripsy

Length(cm)

Page 40: MTW.pdf · ERCP-catheter, reusable All ERCP-catheters with mandrin, and nozzle for injection of contrast medium suitable for guide wire ERCP-catheter,

3

Aus

gabe

2-0

4.04

Article-no. X/Y Diameter (mm) (mm)

Lithotomy baskets, reusable

With a nozzle on the side for injectionof contrast medium

Lithotomy baskets for guide wire, twisted wires

DescriptionGuide wire(inch)

y

x

0.025 0.035

for guide wire0.025 inch

for guide wire0.035 inch

03 11 23 24 15/25 1,8 215 0.025

03 11 24 24 20/30 1,8 215 0.025

03 11 25 24 25/40 1,8 215 0.025

03 11 26 24 30/45 1,8 215 0.025

03 11 27 24 40/55 1,8 215 0.025

03 11 44 34 20/30 2,6 215 0.035

03 11 45 34 25/40 2,6 215 0.035

03 11 46 34 30/45 2,6 215 0.035

03 11 47 34 40/55 2,6 215 0.035

03 11 48 34 45/60 2,6 215 0.035

Handle with nozzle for injection ofcontrast medium. To be used withlying guide wire.

suitable forlithotripsy

Length(cm)

Page 41: MTW.pdf · ERCP-catheter, reusable All ERCP-catheters with mandrin, and nozzle for injection of contrast medium suitable for guide wire ERCP-catheter,

4

03 11 36 08 30/45 2,6 215 —

Article-no. X/Y Diameter (mm) (mm)

Lithotomy baskets, reusable

With a nozzle on the side for injectionof contrast medium

Lithotomy basket, twisted wires

DescriptionGuide wire(inch)

y

x

03 14 44 34 20/30 2,6 215 0.035

Handle with nozzle forinjection of contrast medium

Article-no. X/Y Diameter (mm) (mm)

Lithotomy basket, twisted "double wires"

DescriptionGuide wire(inch)

0.025 0.035

for guide wire0.025 inch

for guide wire0.035 inch

suitable forlithotripsy

x

y

Handle with nozzle for injection ofcontrast medium. To be used withlying guide wire.

Length(cm)

Length(cm)

Page 42: MTW.pdf · ERCP-catheter, reusable All ERCP-catheters with mandrin, and nozzle for injection of contrast medium suitable for guide wire ERCP-catheter,

5

Aus

gabe

2-0

4.04

With a nozzle on the side for injectionof contrast medium

Description

03 12 37 04 35/50 2,3 215 twisted wire

03 12 37 05 35/50 2,3 215 monofil wire

y

x

Article-no. X/Y Diameter (mm) (mm)

Catheter for stone-extraction, 3 monofil wires

Description

x

y

Article-no. X/Y Diameter (mm) (mm)

Lithotomy basket, 6 wires, turned

03 13 22 05 20/20 1,8 215 x = 20 mm, y = 20 mm

03 13 32 05 20/20 2,3 215 x = 20 mm, y = 20 mm

Handle with nozzle forinjection of contrast medium

suitable forlithotripsy

Lithotomy baskets, reusable

Length(cm)

Length(cm)

Page 43: MTW.pdf · ERCP-catheter, reusable All ERCP-catheters with mandrin, and nozzle for injection of contrast medium suitable for guide wire ERCP-catheter,

6

Article-no. X/Y Diameter (mm) (mm)

Lithotomy baskets, reusable

With a nozzle on the side for injectionof contrast medium

Lithotomy basket, diamond-shaped Nitinol®

DescriptionX

Y

03 11 23 02 15/25 1,8 215 4 wires

03 11 24 02 20/30 1,8 215 4 wires

03 11 25 02 25/40 1,8 215 4 wires

03 11 26 02 30/45 1,8 215 4 wires

03 11 27 02 35/55 1,8 215 4 wires

03 11 33 02 15/25 2,3 215 4 wires

03 11 34 02 20/30 2,3 215 4 wires

03 11 35 02 25/40 2,3 215 4 wires

03 11 36 02 30/45 2,3 215 4 wires

03 11 37 02 35/55 2,3 215 4 wires

Handle with nozzle forinjection of contrast medium

NITINOL® is a registered trademark

Not suitable for thelithotripsy!

Length(cm)

Not suitable forthe lithotripsy!

Page 44: MTW.pdf · ERCP-catheter, reusable All ERCP-catheters with mandrin, and nozzle for injection of contrast medium suitable for guide wire ERCP-catheter,

7

Aus

gabe

2-0

4.04

Article-no. X/Y Diameter (mm) (mm)

Lithotomy baskets, reusable

With a nozzle on the side for injectionof contrast medium

Lithotomy basket Nitinol®

Description

03 11 23 03 15/25 1,8 215 6 wires

03 11 24 03 20/30 1,8 215 6 wires

03 11 25 03 25/40 1,8 215 6 wires

03 11 26 03 30/45 1,8 215 6 wires

03 11 27 03 35/55 1,8 215 6 wires

03 11 33 03 15/25 2,3 215 6 wires

03 11 34 03 20/30 2,3 215 6 wires

03 11 35 03 25/40 2,3 215 6 wires

03 11 36 03 30/45 2,3 215 6 wires

03 11 37 03 35/55 2,3 215 6 wires

X

Y

Handle with nozzle forinjection of contrast medium

NITINOL® is a registered trademark

Not suitablefor thelithotripsy!

Not suitable for thelithotripsy!

Length(cm)

Page 45: MTW.pdf · ERCP-catheter, reusable All ERCP-catheters with mandrin, and nozzle for injection of contrast medium suitable for guide wire ERCP-catheter,

8

Article-no. X/Y Diameter (mm) (mm)

Lithotomy baskets, reusable

With a nozzle on the side for injectionof contrast medium

Lithotomy basket, turned, Nitinol®

DescriptionX

Y

Handle with nozzle forinjection of contrast medium

03 12 23 03 15/25 1,8 215 6 wires

03 12 24 03 20/30 1,8 215 6 wires

03 12 25 03 25/40 1,8 215 6 wires

03 12 26 03 30/45 1,8 215 6 wires

03 12 27 03 35/55 1,8 215 6 wires

03 12 33 03 15/25 2,3 215 6 wires

03 12 34 03 20/30 2,3 215 6 wires

03 12 35 03 25/40 2,3 215 6 wires

03 12 36 03 30/45 2,3 215 6 wires

03 12 37 03 35/55 2,3 215 6 wires

NITINOL® is a registered trademark

Not suitablefor thelithotripsy!

Not suitable for thelithotripsy!

Length(cm)

Page 46: MTW.pdf · ERCP-catheter, reusable All ERCP-catheters with mandrin, and nozzle for injection of contrast medium suitable for guide wire ERCP-catheter,

9

Aus

gabe

2-0

4.04

Handle with nozzle forinjection of contrastmedium

Article-no. X/Y Diameter (mm) (mm)

Lithotomy baskets, disposable

Lithotomy basket

Description

99 03 11 35 04 25/40 2,3 215

99 03 11 37 04 40/55 2,3 215

2

y

x

With a nozzle on the side for injectionof contrast medium

Length(cm)

suitable forlithotripsy

All disposable lithotomy baskets are delivered in packaging units.

Packaging unit:5 piecesPackaging unit:5 pieces

Page 47: MTW.pdf · ERCP-catheter, reusable All ERCP-catheters with mandrin, and nozzle for injection of contrast medium suitable for guide wire ERCP-catheter,

10

Article-no. Diametertube (mm)

Emergency-lithotriptor, reusable

Emergency-lithotriptor

Lengthtube (cm)

Description

03 30 0 3,8 100

03 30 6 3,8 100 metal tube, separate

03 36 — — handle for lithotriptor

Article-no. X/Y Diameter (mm) (mm)

Lithotomy basket, twisted wires

Description

y

x

suitable forlithotripsy

03 11 31 04 10/20 2,3 215

03 11 33 04 15/25 2,3 215

03 11 34 04 20/30 2,3 215

03 11 35 04 25/40 2,3 215

03 11 36 04 30/45 2,3 215

03 11 37 04 40/55 2,3 215

03 11 38 04 45/60 2,3 215

03 11 34 06 20/30 2,3 215 6 wires (without illustration)

03 11 36 06 30/45 2,3 215 6 wires (without illustration))

Length(cm)

Fixingsolvable

complete set: consisting of handleand metal tube

Page 48: MTW.pdf · ERCP-catheter, reusable All ERCP-catheters with mandrin, and nozzle for injection of contrast medium suitable for guide wire ERCP-catheter,

1

Lithotriptor, reusable

This lithotriptor is autoclavable.

Additional basket: see page 13 of this chapter!

Lithotripsythrough theendoscope

suitable forlithotripsy

Article-no.

Combi-bile-stone-lithotriptor set

Description

teflon tubeØ 2,3 mm

Ø 3,8 mmlength 100 cm

y

x

x/mm y/mm 40 55

Ø 2,3 mmlength 195 cm

Fixingsolvable

03 31 47 09 Combi-bile-stone-lithotriptor set incl. emergency-lithotriptor

consisting of: handle, 1 metal tube Ø 2,3 mm,length 195 cm for lithotripsy through theendoscope, connector for metal tube Ø 2,3 mm,2 baskets, basket measure x = 40 mm /y = 55 mm, length 4 m with PTFE-introducer-tube, 1 metal tube Ø 3,8 mm, length 100 cmfor emergency lithotripsy without endoscope

03 30 4 Metal tube, separate, Ø 2,3 mm, length 195 cm

03 30 6 Metal tube, separate, Ø 3,8 mm, length 100 cm

03 35 4 Connector for metal tube, Ø 2,3 mm

Page 49: MTW.pdf · ERCP-catheter, reusable All ERCP-catheters with mandrin, and nozzle for injection of contrast medium suitable for guide wire ERCP-catheter,

1

Aus

gabe

2-0

4.04

Article-no. X/Y Diameter (mm) (mm)

Lithotriptor accessories, reusable

With a nozzle on the side for injectionof contrast medium

Additional baskets for lithotriptor

Description

03 31 36 04 30/45 2,3 400 4 wires

03 31 37 04 40/55 2,3 400 4 wires

03 31 38 04 45/60 2,3 400 4 wires

Article-no. X/Y Diameter (mm) (mm)

Additional baskets for lithotriptor

Description

03 32 37 04 35/50 2,3 400 6 wires

y

x

y

x

Nozzle for injectionof contrast medium

suitable forlithotripsy

Length(cm)

Length(cm)

Page 50: MTW.pdf · ERCP-catheter, reusable All ERCP-catheters with mandrin, and nozzle for injection of contrast medium suitable for guide wire ERCP-catheter,

Endoprostheses& PTC-�������

Endoscopic instrumentsand accessories

4

Page 51: MTW.pdf · ERCP-catheter, reusable All ERCP-catheters with mandrin, and nozzle for injection of contrast medium suitable for guide wire ERCP-catheter,
Page 52: MTW.pdf · ERCP-catheter, reusable All ERCP-catheters with mandrin, and nozzle for injection of contrast medium suitable for guide wire ERCP-catheter,

2

Guiding-systems: see page 9, 10, 11

Endoprostheses, disposable

2

Straight endoprostheses, grey, Teflon

Ch. 7.0 Length between Total lengthArticle-no. the flaps (cm) (cm)

04 00 70 10 03 3 5

04 00 70 10 04 4 6

04 00 70 10 05 5 7

04 00 70 10 06 6 8

04 00 70 10 07 7 9

04 00 70 10 08 8 10

04 00 70 10 09 9 11

04 00 70 10 10 10 12

04 00 70 10 11 11 13

04 00 70 10 12 12 14

04 00 70 10 13 13 15

Ch. 8.5 Length between Total lengthArticle-no. the flaps (cm) (cm)

04 00 80 10 03 3 5

04 00 80 10 04 4 6

04 00 80 10 05 5 7

04 00 80 10 06 6 8

04 00 80 10 07 7 9

04 00 80 10 08 8 10

04 00 80 10 09 9 11

04 00 80 10 10 10 12

04 00 80 10 11 11 13

04 00 80 10 12 12 14

04 00 80 10 13 13 15

Ch. 10.0 Length between Total lengthArticle-no. the flaps (cm) (cm)

04 01 00 10 03 3 5

04 01 00 10 04 4 6

04 01 00 10 05 5 7

04 01 00 10 06 6 8

04 01 00 10 07 7 9

04 01 00 10 08 8 10

04 01 00 10 09 9 11

04 01 00 10 10 10 12

04 01 00 10 11 11 13

04 01 00 10 12 12 14

04 01 00 10 13 13 15

Ch. 11.5 Length between Total lengthArticle-no. the flaps (cm) (cm)

04 01 10 10 03 3 5

04 01 10 10 04 4 6

04 01 10 10 05 5 7

04 01 10 10 06 6 8

04 01 10 10 07 7 9

04 01 10 10 08 8 10

04 01 10 10 09 9 11

04 01 10 10 10 10 12

04 01 10 10 11 11 13

04 01 10 10 12 12 14

04 01 10 10 13 13 15

Length between the flaps

Total length

Page 53: MTW.pdf · ERCP-catheter, reusable All ERCP-catheters with mandrin, and nozzle for injection of contrast medium suitable for guide wire ERCP-catheter,

3

Aus

gabe

2-0

4.04

Guiding-systems: see page 9, 10, 11

Endoprostheses with metal ring, disposable

2

Straight endoprostheses with metal ring, grey, Teflon

Ch. 7.0 Length between Total lengthArticle-no. the flaps (cm) (cm)

04 20 70 10 03 3 5

04 20 70 10 04 4 6

04 20 70 10 05 5 7

04 20 70 10 06 6 8

04 20 70 10 07 7 9

04 20 70 10 08 8 10

04 20 70 10 09 9 11

04 20 70 10 10 10 12

04 20 70 10 11 11 13

04 20 70 10 12 12 14

04 20 70 10 13 13 15

Ch. 8.5 Length between Total lengthArticle-no. the flaps (cm) (cm)

04 20 80 10 03 3 5

04 20 80 10 04 4 6

04 20 80 10 05 5 7

04 20 80 10 06 6 8

04 20 80 10 07 7 9

04 20 80 10 08 8 10

04 20 80 10 09 9 11

04 20 80 10 10 10 12

04 20 80 10 11 11 13

04 20 80 10 12 12 14

04 20 80 10 13 13 15

Ch. 10.0 Length between Total lengthArticle-no. the flaps (cm) (cm)

04 21 00 10 03 3 5

04 21 00 10 04 4 6

04 21 00 10 05 5 7

04 21 00 10 06 6 8

04 21 00 10 07 7 9

04 21 00 10 08 8 10

04 21 00 10 09 9 11

04 21 00 10 10 10 12

04 21 00 10 11 11 13

04 21 00 10 12 12 14

04 21 00 10 13 13 15

Ch. 11.5 Length between Total lengthArticle-no. the flaps (cm) (cm)

04 21 10 10 03 3 5

04 21 10 10 04 4 6

04 21 10 10 05 5 7

04 21 10 10 06 6 8

04 21 10 10 07 7 9

04 21 10 10 08 8 10

04 21 10 10 09 9 11

04 21 10 10 10 10 12

04 21 10 10 11 11 13

04 21 10 10 12 12 14

04 21 10 10 13 13 15

Length between the flaps

Total length

Page 54: MTW.pdf · ERCP-catheter, reusable All ERCP-catheters with mandrin, and nozzle for injection of contrast medium suitable for guide wire ERCP-catheter,

4

Guiding-systems: see page 9, 10, 11

Endoprostheses, disposable

2

Ch. 7.0 Length between Total lengthArticle-no. the flaps (cm) (cm)

04 50 70 10 03 3 5

04 50 70 10 04 4 6

04 50 70 10 05 5 7

04 50 70 10 06 6 8

04 50 70 10 07 7 9

04 50 70 10 08 8 10

04 50 70 10 09 9 11

04 50 70 10 10 10 12

04 50 70 10 11 11 13

04 50 70 10 12 12 14

04 50 70 10 13 13 15

Ch. 8.5 Length between Total lengthArticle-no. the flaps (cm) (cm)

04 50 80 10 03 3 5

04 50 80 10 04 4 6

04 50 80 10 05 5 7

04 50 80 10 06 6 8

04 50 80 10 07 7 9

04 50 80 10 08 8 10

04 50 80 10 09 9 11

04 50 80 10 10 10 12

04 50 80 10 11 11 13

04 50 80 10 12 12 14

04 50 80 10 13 13 15

Ch. 10.0 Length between Total lengthArticle-no. the flaps (cm) (cm)

04 51 00 10 03 3 5

04 51 00 10 04 4 6

04 51 00 10 05 5 7

04 51 00 10 06 6 8

04 51 00 10 07 7 9

04 51 00 10 08 8 10

04 51 00 10 09 9 11

04 51 00 10 10 10 12

04 51 00 10 11 11 13

04 51 00 10 12 12 14

04 51 00 10 13 13 15

Ch. 11.5 Length between Total lengthArticle-no. the flaps (cm) (cm)

04 51 10 10 03 3 5

04 51 10 10 04 4 6

04 51 10 10 05 5 7

04 51 10 10 06 6 8

04 51 10 10 07 7 9

04 51 10 10 08 8 10

04 51 10 10 09 9 11

04 51 10 10 10 10 12

04 51 10 10 11 11 13

04 51 10 10 12 12 14

04 51 10 10 13 13 15

Length between the flaps

Total length

Straight endoprostheses, model soft, blue, Polyethylen

Page 55: MTW.pdf · ERCP-catheter, reusable All ERCP-catheters with mandrin, and nozzle for injection of contrast medium suitable for guide wire ERCP-catheter,

5

Aus

gabe

2-0

4.04

Guiding-systems: see page 9, 10, 11

Endoprostheses, disposable

2

Ch. 7.0 Length between Total lengthArticle-no. the flaps (cm) (cm)

04 60 70 10 03 3 5

04 60 70 10 04 4 6

04 60 70 10 05 5 7

04 60 70 10 06 6 8

04 60 70 10 07 7 9

04 60 70 10 08 8 10

04 60 70 10 09 9 11

04 60 70 10 10 10 12

04 60 70 10 11 11 13

04 60 70 10 12 12 14

04 60 70 10 13 13 15

Ch. 8.5 Length between Total lengthArticle-no. the flaps (cm) (cm)

04 60 80 10 03 3 5

04 60 80 10 04 4 6

04 60 80 10 05 5 7

04 60 80 10 06 6 8

04 60 80 10 07 7 9

04 60 80 10 08 8 10

04 60 80 10 09 9 11

04 60 80 10 10 10 12

04 60 80 10 11 11 13

04 60 80 10 12 12 14

04 60 80 10 13 13 15

Ch. 10.0 Length between Total lengthArticle-no. the flaps (cm) (cm)

04 61 00 10 03 3 5

04 61 00 10 04 4 6

04 61 00 10 05 5 7

04 61 00 10 06 6 8

04 61 00 10 07 7 9

04 61 00 10 08 8 10

04 61 00 10 09 9 11

04 61 00 10 10 10 12

04 61 00 10 11 11 13

04 61 00 10 12 12 14

04 61 00 10 13 13 15

Ch. 11.5 Length between Total lengthArticle-no. the flaps (cm) (cm)

04 61 10 10 03 3 5

04 61 10 10 04 4 6

04 61 10 10 05 5 7

04 61 10 10 06 6 8

04 61 10 10 07 7 9

04 61 10 10 08 8 10

04 61 10 10 09 9 11

04 61 10 10 10 10 12

04 61 10 10 11 11 13

04 61 10 10 12 12 14

04 61 10 10 13 13 15

Length between the flaps

Total length

Straight endoprostheses, model soft with metal ring, blue, Polyethylen

Page 56: MTW.pdf · ERCP-catheter, reusable All ERCP-catheters with mandrin, and nozzle for injection of contrast medium suitable for guide wire ERCP-catheter,

6

2

Endoprostheses, disposable

Article-no.

10-Flap-endoprostheses, grey, Teflon

Length betweenthe flaps

(cm)

Total lengthCh.

04 00 70 20 05 7.0 5 7,5

04 00 70 20 07 7.0 7 9,5

04 00 70 20 09 7.0 9 11,5

04 00 70 20 12 7.0 12 14,5

04 00 80 20 05 8.5 5 7,5

04 00 80 20 07 8.5 7 9,5

04 00 80 20 09 8.5 9 11,5

04 00 80 20 12 8.5 12 14,5

04 01 00 20 05 10.0 5 7,5

04 01 00 20 07 10.0 7 9,5

04 01 00 20 09 10.0 9 11,5

04 01 00 20 12 10.0 12 14,5

04 01 10 20 05 11.5 5 7,5

04 01 10 20 07 11.5 7 9,5

04 01 10 20 09 11.5 9 11,5

04 01 10 20 12 11.5 12 14,5

Total length

Length between the flaps

(cm)

Guiding-systems: see page 9, 10, 11

Page 57: MTW.pdf · ERCP-catheter, reusable All ERCP-catheters with mandrin, and nozzle for injection of contrast medium suitable for guide wire ERCP-catheter,
Page 58: MTW.pdf · ERCP-catheter, reusable All ERCP-catheters with mandrin, and nozzle for injection of contrast medium suitable for guide wire ERCP-catheter,

8

Article-no.

Double-pigtail-endoprostheses, grey, Teflon

DescriptionTotallength(cm)

Ch.

04 00 70 40 05 7.0 5 9 for guide wire 0.035

04 00 70 40 07 7.0 7 11

04 00 70 40 09 7.0 9 13

04 00 70 40 12 7.0 12 16

04 00 80 40 05 8.5 5 9

04 00 80 40 07 8.5 7 11

04 00 80 40 09 8.5 9 13

04 00 80 40 12 8.5 12 16

Pusher

04 00 71 7 7.0 250

04 00 81 0 8.5 165

Article-no. DescriptionTotallength(cm)

Ch.

Endoprostheses, disposable

2

Length between the pigs

(cm)

Total length

Length cm

"Cleaning connector for pusher Ch. 7 to Ch. 10, see chapter 10 page 8"

Page 59: MTW.pdf · ERCP-catheter, reusable All ERCP-catheters with mandrin, and nozzle for injection of contrast medium suitable for guide wire ERCP-catheter,

04 01 02 20 09 Endoprosthesis, separate, Charr. 10, length between the flaps 6 cm, total length 9 cm

04 01 22 20 09 Endoprosthesis, separate, Charr. 12, length between the flaps 6 cm, total length 9 cm

04 01 42 20 09 Endoprosthesis, separate, Charr. 14, length between the flaps 6 cm, total length 9 cm

Endoprostheses-set

Article-no.

Endoprostheses-setProf. Kautz

Description

04 01 42 2 Endoprostheses-set for large caliber bile duct

consisting of: - 1 guide instrument, Ø 1,8 mm

- 1 pusher

- 1 handle

04 00 22 2 Handle, separate

04 00 02 2 Guide-instrument, separate Ø 1,8 mm

04 00 12 2 Pusher, separate

With the non transendoscopical method ofTPCD higher success rates and improveon results are to obtain than with thetransendoscopical method. Withoutendoscope changes 14 – 18 Frenchendoprostheses can be implanted withduodenoscopes, which suggest smallerearly and late complication and ensure anefficient drainage.

Endoprostheses-set for model Prof. Kautz

Article-no. Description

2

2

2

Length between the flaps

Total length

rechts: Special design on requestpossible in Charr. 10, 12, 14, 16and of the length between5 - 17 cm

Page 60: MTW.pdf · ERCP-catheter, reusable All ERCP-catheters with mandrin, and nozzle for injection of contrast medium suitable for guide wire ERCP-catheter,

1

Aus

gabe

2-0

4.04

Article-no.

These dilatation catheters are radiopaque.

Dilatation catheters for endoprosthesesmodel Prof. Kautz

DescriptionTotallength(cm)

Ch.

Dilatation catheters, reusable

Ch.10 Ch. 12 Ch. 14 Ch. 16 Ch. 18 Ch. 20

04 11 00 01 05 10 105

04 11 20 01 05 12 105

04 11 40 01 05 14 105

04 11 60 01 05 16 105

04 11 80 01 05 18 105

04 12 00 01 05 20 105

Page 61: MTW.pdf · ERCP-catheter, reusable All ERCP-catheters with mandrin, and nozzle for injection of contrast medium suitable for guide wire ERCP-catheter,

1

Article-no.

These dilatation catheters are radiopaque.

Dilatation catheters

DescriptionTotallength(cm)

Ch.

04 10 50 02 00 5 200 guide wire arrestable

04 10 70 02 00 7 200 metal ring inside

04 10 80 02 00 8 200

04 10 90 02 00 9 200

04 11 00 02 00 10 200

04 11 20 02 00 12 200

Dilatation catheters, reusable

0.035

for guide wire0.035 inch

for injection ofcontrast medium

Page 62: MTW.pdf · ERCP-catheter, reusable All ERCP-catheters with mandrin, and nozzle for injection of contrast medium suitable for guide wire ERCP-catheter,
Page 63: MTW.pdf · ERCP-catheter, reusable All ERCP-catheters with mandrin, and nozzle for injection of contrast medium suitable for guide wire ERCP-catheter,

Article-no.

Nasobiliary drainage catheter

Description

04 00 55 54 00 5

04 00 75 54 00 7

04 01 05 54 00 10

Nasobiliary drainage catheters, disposable

2

Ch.

Nasobiliary drainage catheter consisting of:Catheter standard with 7 side holes, length 290 cm,injection connector, funnel 3-way stopcockconnector, length 135 cm, nasal tube, length 50 cm

Article-no.

Nasobiliary drainage catheter

Description

04 00 55 64 00 5

04 00 75 64 00 7

Ch.

Nasobiliary drainage catheter consisting of:Catheter standard with pigtail with & 7 side holes,length 290 cm, injection connector, funnel 3-waystopcock connector, length 135 cm, nasal tube, length50 cm

Page 64: MTW.pdf · ERCP-catheter, reusable All ERCP-catheters with mandrin, and nozzle for injection of contrast medium suitable for guide wire ERCP-catheter,

Aus

gabe

2-0

4.04

Nasobiliary drainage catheters, disposable

Article-no.

Nasobiliary drainage catheter

Description

04 00 55 34 00 5

04 00 75 34 00 7

Ch.

Nasobiliary drainage catheter consisting of:Catheter with pigtail & 8 side holes, length290 cm, injection connector, funnel 3-waystopcock connector, length 135 cm, nasaltube, length 50 cm

2

Page 65: MTW.pdf · ERCP-catheter, reusable All ERCP-catheters with mandrin, and nozzle for injection of contrast medium suitable for guide wire ERCP-catheter,

Article-no.

Pneumatic dilator for treatment ofachalasia

Description

04 20 07 7 Pneumatic dilator model Witzel, complete

04 20 07 8 Dilator, separate

04 20 07 9 Manometer, separate

Pneumatic dilator, reusable

Products showing this sign can besterilized but not autoclaved

134 0C

134 0C

134 0C

134 0C

Page 66: MTW.pdf · ERCP-catheter, reusable All ERCP-catheters with mandrin, and nozzle for injection of contrast medium suitable for guide wire ERCP-catheter,

Polypectomysnares

Endoscopic instrumentsand accessories

5

Page 67: MTW.pdf · ERCP-catheter, reusable All ERCP-catheters with mandrin, and nozzle for injection of contrast medium suitable for guide wire ERCP-catheter,
Page 68: MTW.pdf · ERCP-catheter, reusable All ERCP-catheters with mandrin, and nozzle for injection of contrast medium suitable for guide wire ERCP-catheter,
Page 69: MTW.pdf · ERCP-catheter, reusable All ERCP-catheters with mandrin, and nozzle for injection of contrast medium suitable for guide wire ERCP-catheter,
Page 70: MTW.pdf · ERCP-catheter, reusable All ERCP-catheters with mandrin, and nozzle for injection of contrast medium suitable for guide wire ERCP-catheter,
Page 71: MTW.pdf · ERCP-catheter, reusable All ERCP-catheters with mandrin, and nozzle for injection of contrast medium suitable for guide wire ERCP-catheter,
Page 72: MTW.pdf · ERCP-catheter, reusable All ERCP-catheters with mandrin, and nozzle for injection of contrast medium suitable for guide wire ERCP-catheter,
Page 73: MTW.pdf · ERCP-catheter, reusable All ERCP-catheters with mandrin, and nozzle for injection of contrast medium suitable for guide wire ERCP-catheter,
Page 74: MTW.pdf · ERCP-catheter, reusable All ERCP-catheters with mandrin, and nozzle for injection of contrast medium suitable for guide wire ERCP-catheter,
Page 75: MTW.pdf · ERCP-catheter, reusable All ERCP-catheters with mandrin, and nozzle for injection of contrast medium suitable for guide wire ERCP-catheter,
Page 76: MTW.pdf · ERCP-catheter, reusable All ERCP-catheters with mandrin, and nozzle for injection of contrast medium suitable for guide wire ERCP-catheter,

10

Article-no. Diameter (mm)

Asymmetrical polypectomy snares

Length(cm)

DescriptionOpening-width

(X=mm)

Polypectomy snares, reusable

05 20 10 24 8 2,3 230 40

05 20 30 24 8 2,3 230 40

Extra handleArticle-no. 10 02 07 8

Article-no. Diameter (mm)

Asymmetrical polypectomy snares

Length(cm)

DescriptionOpening-width

(X=mm)

05 20 10 26 8 2,3 230 60

05 20 30 26 8 2,3 230 60

x =

40x

= 60

Use this polypectomy snareonly with the enclosed handleplease.

Use this polypectomy snareonly with the enclosed handleplease.

isolated tip

Page 77: MTW.pdf · ERCP-catheter, reusable All ERCP-catheters with mandrin, and nozzle for injection of contrast medium suitable for guide wire ERCP-catheter,
Page 78: MTW.pdf · ERCP-catheter, reusable All ERCP-catheters with mandrin, and nozzle for injection of contrast medium suitable for guide wire ERCP-catheter,
Page 79: MTW.pdf · ERCP-catheter, reusable All ERCP-catheters with mandrin, and nozzle for injection of contrast medium suitable for guide wire ERCP-catheter,
Page 80: MTW.pdf · ERCP-catheter, reusable All ERCP-catheters with mandrin, and nozzle for injection of contrast medium suitable for guide wire ERCP-catheter,
Page 81: MTW.pdf · ERCP-catheter, reusable All ERCP-catheters with mandrin, and nozzle for injection of contrast medium suitable for guide wire ERCP-catheter,

15

Aus

gabe

2-0

4.04

Article-no. Diameter (mm)

Coagulation probe with nozzle for sucking off

Length(cm)

Description

Coagulation probe, reusable

10 25 05 2 2,3 215

Page 82: MTW.pdf · ERCP-catheter, reusable All ERCP-catheters with mandrin, and nozzle for injection of contrast medium suitable for guide wire ERCP-catheter,
Page 83: MTW.pdf · ERCP-catheter, reusable All ERCP-catheters with mandrin, and nozzle for injection of contrast medium suitable for guide wire ERCP-catheter,
Page 84: MTW.pdf · ERCP-catheter, reusable All ERCP-catheters with mandrin, and nozzle for injection of contrast medium suitable for guide wire ERCP-catheter,
Page 85: MTW.pdf · ERCP-catheter, reusable All ERCP-catheters with mandrin, and nozzle for injection of contrast medium suitable for guide wire ERCP-catheter,

Biopsy-forcepsRectoscopy-forceps

& shaft

Endoscopic instrumentsand accessories

6

Page 86: MTW.pdf · ERCP-catheter, reusable All ERCP-catheters with mandrin, and nozzle for injection of contrast medium suitable for guide wire ERCP-catheter,
Page 87: MTW.pdf · ERCP-catheter, reusable All ERCP-catheters with mandrin, and nozzle for injection of contrast medium suitable for guide wire ERCP-catheter,
Page 88: MTW.pdf · ERCP-catheter, reusable All ERCP-catheters with mandrin, and nozzle for injection of contrast medium suitable for guide wire ERCP-catheter,
Page 89: MTW.pdf · ERCP-catheter, reusable All ERCP-catheters with mandrin, and nozzle for injection of contrast medium suitable for guide wire ERCP-catheter,
Page 90: MTW.pdf · ERCP-catheter, reusable All ERCP-catheters with mandrin, and nozzle for injection of contrast medium suitable for guide wire ERCP-catheter,

5

Aus

gabe

2-0

4.04

Article-no. Diameter (mm)

Biopsy-forceps, reusable

Biopsy-forceps, alligator jaws

Description

06 10 03 00 1 0,75 160

06 10 03 00 4 0,75 230

06 11 03 00 1 1,0 160

06 11 03 00 3 1,0 230

06 13 03 00 1 1,5 160

06 13 03 00 3 1,5 230

Biopsy-forceps, alligator jaws, with spike

Article-no. Diameter (mm)

06 15 13 11 1 2,2 160 fenestrated, tapered

06 15 13 11 4 2,2 230 fenestrated, tapered

Description

Length(cm)

Length(cm)

Handle used for PTFE-coated forceps

Handle, standard

PTFE-coating and nozzle on the side to wash-out is possible by request

Stopper for handle to be used for reprocessing, chapter 6, page 11 and chapter 10, page 9

Page 91: MTW.pdf · ERCP-catheter, reusable All ERCP-catheters with mandrin, and nozzle for injection of contrast medium suitable for guide wire ERCP-catheter,

6

Article-no. Diameter (mm)

Biopsy-forceps, reusable

Biopsy-forceps, oval spoonshaped mouth with one tooth

Description

06 15 07 10 1 2,2 160 fenestrated, tapered

06 15 07 10 4 2,2 230 fenestrated, tapered

Biopsy-forceps, oval spoonshaped swinging mouth, without spike

Article-no. Diameter (mm)

06 15 02 22 5 2,2 180 fenestrated, tapered

Description

Length(cm)

Length(cm)

Handle used for PTFE-coated forceps

Handle, standard

PTFE-coating and nozzle on the side to wash-out is possible by request

Stopper for handle to be used for reprocessing, chapter 6, page 11 and chapter 10, page 9

Page 92: MTW.pdf · ERCP-catheter, reusable All ERCP-catheters with mandrin, and nozzle for injection of contrast medium suitable for guide wire ERCP-catheter,

7

Aus

gabe

2-0

4.04

Article-no. Diameter (mm)

Biopsy-forceps, reusable

Biopsy-forceps, oval spoonshaped swinging mouth, with tooth

Handle, standard

Description

06 15 03 22 5 2,2 180 fenestrated, tapered

Biopsy-forceps, oval spoonshaped, lateral mouth, without spike

Article-no. Diameter (mm)

06 14 08 00 1 1,8 160 fenestrated, tapered

06 15 08 00 5 1,8 180

06 14 08 00 2 1,8 230

06 14 08 20 1 2,2 160

06 15 08 20 5 2,2 180

06 14 08 20 2 2,2 230

DescriptionLength(cm)

Length(cm)

Handle used for PTFE-coated forceps

PTFE-coating and nozzle on the side to wash-out is possible by request

Stopper for handle to be used for reprocessing, chapter 6, page 11 and chapter 10, page 9

Page 93: MTW.pdf · ERCP-catheter, reusable All ERCP-catheters with mandrin, and nozzle for injection of contrast medium suitable for guide wire ERCP-catheter,

8

Article-no. Diameter (mm)

Hot-biopsy-forceps, reusable

Hot-biopsy-forceps, oval spoonshaped mouth

Description

06 28 01 00 1 3,4 160

06 28 01 00 4 3,4 230

Hot-biopsy-forceps, oval spoonshaped mouth

Article-no. Diameter (mm)

Description

Handle with a nozzleon the side to wash-out

isolated, PTFE-coated

06 24 02 00 1 1,8 160 isolated, PTFE-coated

06 24 02 00 4 1,8 230

06 25 02 00 1 2,2 160

06 25 02 00 5 2,2 180

06 25 02 00 4 2,2 230

06 26 02 00 1 2,6 160

06 26 02 00 5 2,6 180

06 26 02 00 4 2,6 230

Length(cm)

Length(cm)

Stopper for handle to be used for reprocessing, chapter 6, page 11 and chapter 10, page 9

Page 94: MTW.pdf · ERCP-catheter, reusable All ERCP-catheters with mandrin, and nozzle for injection of contrast medium suitable for guide wire ERCP-catheter,

9

Aus

gabe

2-0

4.04

Article-no. Diameter (mm)

Rectoscopy-forceps, reusable

Rectoscopy-forceps, inflexible, PTFE-coated

Description

06 35 02 10 0 2,2 50 without spike, fenestrated (a)

06 35 02 11 0 2,2 50 with spike, fenestrated (b)

Rectoscopy-forceps, inflexible, PTFE-coated

Article-no. Diameter (mm)

06 38 01 10 0 3,4 50 without spike, fenestrated (c)

06 38 01 11 0 3,4 50 with spike, fenestrated (d)

Description

(a) (b)

(c) (d)

All rectoscopy-forceps arePTFE-coated

Length(cm)

Length(cm)

Stopper for handle to be used for reprocessing, chapter 6, page 11 and chapter 10, page 9

Page 95: MTW.pdf · ERCP-catheter, reusable All ERCP-catheters with mandrin, and nozzle for injection of contrast medium suitable for guide wire ERCP-catheter,

1

Aus

gabe

2-0

4.04

Accessories, reusable

Clip for instruments

Article-no. Description

00 20 0The clips for instruments are manufactured with high-qualitysurgical steel and therefore

- guaranteed stainless- autoclavable by 134° C- extremely durable

The clips for instruments are the solution of:- safekeeping of your guide wires and flexible accessories

The clips for instruments prevent from tangling of guide wiresand are suitable for all diameters of guide wires and accessorieslike ERCP-catheters and polypectomy snares.

Minimum order qty.: 25 pieces

Stopper for handleArticle-no. Description

00 10 0 the stoppers are to be used

- for effective reprocessing of biopsy- and foreign-body removingforceps

- as tension stopper to avoid too strong bending for example withpapillotomes

By putting on the stopper at the handle of forceps it is ensuredthat the spoons at the distal end will stay open during repro-cessing and no blood or tissue particles adhere at the spoons.Minimum order quantity 25 pieces"

Page 96: MTW.pdf · ERCP-catheter, reusable All ERCP-catheters with mandrin, and nozzle for injection of contrast medium suitable for guide wire ERCP-catheter,

Foreign-bodyremoving

forceps

Endoscopic instrumentsand accessories

7

Page 97: MTW.pdf · ERCP-catheter, reusable All ERCP-catheters with mandrin, and nozzle for injection of contrast medium suitable for guide wire ERCP-catheter,

1

Aus

gabe

2-0

4.04

Article-no. Diameter (mm)

Foreign-body removing forceps, reusable

These foreign-body removing forceps have a Teflon tube and a nozzle on theside to wash-out

Polypotome with Teflon tube

Handle with a nozzle on the sideto wash-out

DescriptionLength(cm)

07 20 21 3 2,5 160 30 3-arm

07 20 22 3 2,5 230 30 3-arm

07 34 41 3 2,5 160 30 4-arm

07 34 42 3 2,5 230 30 4-arm

07 35 51 3 2,5 160 30 5-arm

07 35 52 3 2,5 230 30 5-arm

Stationary polypotome, 3-arm

07 20 21 4 2,6 160 25 3-arm

07 20 22 4 2,6 230 25 3-arm

Opening-width

(X=mm)x

Article-no. Diameter (mm)

DescriptionLength(cm)

Opening-width

(X=mm)

x

Stopper for handle to be used for reprocessing, chapter 6, page 11 and chapter 10, page 9

Page 98: MTW.pdf · ERCP-catheter, reusable All ERCP-catheters with mandrin, and nozzle for injection of contrast medium suitable for guide wire ERCP-catheter,

2

Article-no. Diameter (mm)

DescriptionLength(cm)

Opening-width

(X=mm)

Foreign-body removing forceps, reusable

Foreign-body removing forceps with Teflon tube

07 20 11 3 2,5 160 30 3-arm

07 20 12 3 2,5 230 30 3-arm

07 34 01 3 2,5 160 30 4-arm

07 34 02 3 2,5 230 30 4-arm

07 35 01 3 2,5 160 30 5-arm

07 35 02 3 2,5 230 30 5-arm

These foreign-body removing forceps have a Teflon tube and anozzle on the side to wash-out

x

Handle with a nozzle on the sideto wash-out

Stopper for handle to be used for reprocessing, chapter 6, page 11 and chapter 10, page 9

Page 99: MTW.pdf · ERCP-catheter, reusable All ERCP-catheters with mandrin, and nozzle for injection of contrast medium suitable for guide wire ERCP-catheter,

3

Aus

gabe

2-0

4.04

Length(cm)

Opening-width

(X=mm)

Article-no. Diameter (mm)

07 10 11 0 1,8 160 30 3-nail

07 10 12 0 1,8 230 30

07 20 11 0 2,2 160 30

07 20 12 0 2,2 230 30

Article-no. Diameter (mm)

Length(cm)

Opening-width

(X=mm)

Foreign-body removing forceps, reusable

Polypotome, metal spring

Handle

Foreign-body removing forceps, metal spring

Description

07 20 21 0 2,2 160 30 3-arm

07 20 22 0 2,2 230 30 3-arm

Description

x

x

Stopper for handle to be used for reprocessing, chapter 6, page 11 and chapter 10, page 9

Page 100: MTW.pdf · ERCP-catheter, reusable All ERCP-catheters with mandrin, and nozzle for injection of contrast medium suitable for guide wire ERCP-catheter,

4

Article-no. Diameter (mm)

Foreign-body removing forceps, reusable

Foreign-body removing forceps, „W-shape“, metal spring

Handle

Description

07 10 41 0 1,8 160

07 10 42 0 1,8 230

07 20 41 0 2,2 160

07 20 42 0 2,2 230

Foreign-body removing forceps, forked jaws, metal spring

Article-no. Diameter (mm)

Description

07 10 51 0 1,8 160

07 10 52 0 1,8 230

07 20 51 0 2,2 160

07 20 52 0 2,2 230

Length(cm)

Length(cm)

Stopper for handle to be used for reprocessing, chapter 6, page 11 and chapter 10, page 9

Page 101: MTW.pdf · ERCP-catheter, reusable All ERCP-catheters with mandrin, and nozzle for injection of contrast medium suitable for guide wire ERCP-catheter,

5

Aus

gabe

2-0

4.04

Article-no. Diameter (mm)

Foreign-body removing forceps, reusable

Foreign-body removing forceps, metal spring

Handle

Description

07 10 71 0 1,8 160 alligator jaws

07 10 72 0 1,8 230

07 20 71 2 2,2 160 tapered

07 20 72 2 2,2 230 tapered

Foreign-body removing forceps, metal spring

Article-no. Diameter (mm)

07 20 91 0 2,2 160 long alligator jaws

07 20 92 0 2,2 230 long alligator jaws

Description

Length(cm)

Length(cm)

Stopper for handle to be used for reprocessing, chapter 6, page 11 and chapter 10, page 9

Page 102: MTW.pdf · ERCP-catheter, reusable All ERCP-catheters with mandrin, and nozzle for injection of contrast medium suitable for guide wire ERCP-catheter,

6

Article-no. Diameter (mm)

Foreign-body removing forceps, reusable

Foreign-body removing forceps, rat-tooth

Handle

Description

07 10 61 0 1,8 160

07 10 62 0 1,8 230

07 20 61 0 2,2 160

07 20 62 0 2,2 230

07 30 61 0 3,0 160

07 30 62 0 3,0 230

Foreign-body removing forceps, rat-tooth

Article-no. Diameter (mm)

Description

07 21 31 0 2,2 160 long alligator jaws

07 21 32 0 2,2 230 long alligator jaws

Length(cm)

Length(cm)

Stopper for handle to be used for reprocessing, chapter 6, page 11 and chapter 10, page 9

Page 103: MTW.pdf · ERCP-catheter, reusable All ERCP-catheters with mandrin, and nozzle for injection of contrast medium suitable for guide wire ERCP-catheter,

7

Aus

gabe

2-0

4.04

Article-no. Diameter (mm)

Foreign-body removing forceps, reusable

Foreign-body removing forceps, long alligator jaws, metal spring

Handle

Description

07 21 01 0 2,2 160

07 21 02 0 2,2 230

Grasping forceps for nutrition probes

Article-no. Diameter (mm)

07 31 24 3 2,5 320

Description

Length(cm)

Length(cm)

Stopper for handle to be used for reprocessing, chapter 6, page 11 and chapter 10, page 9

Page 104: MTW.pdf · ERCP-catheter, reusable All ERCP-catheters with mandrin, and nozzle for injection of contrast medium suitable for guide wire ERCP-catheter,

8

Article-no. Diameter (mm)

Foreign-body removing forceps, reusable

Foreign-body removing forceps, metal spring

Description

07 10 31 0 1,8 160 flat overlay, toothed

07 10 32 0 1,8 230

07 20 31 0 2,2 160

07 20 32 0 2,2 230

PEG-forceps, metal spring

Article-no. Diameter (mm)

Description

Handle

07 21 23 0 2,6 180

Length(cm)

Length(cm)

Stopper for handle to be used for reprocessing, chapter 6, page 11 and chapter 10, page 9

Page 105: MTW.pdf · ERCP-catheter, reusable All ERCP-catheters with mandrin, and nozzle for injection of contrast medium suitable for guide wire ERCP-catheter,

9

Aus

gabe

2-0

4.04

Article-no. Diameter (mm)

Foreign-body removing forceps, reusable

Forceps, scissor-shaped, metal spring

DescriptionLength (cm)

Stamp for threads, metal spring

Article-no. Diameter (mm)

Description

Handle

07 20 81 0 2,2 160

07 20 82 0 2,2 230

07 21 11 0 2,2 160

07 21 12 0 2,2 230

Length(cm)

Stopper for handle to be used for reprocessing, chapter 6, page 11 and chapter 10, page 9

Page 106: MTW.pdf · ERCP-catheter, reusable All ERCP-catheters with mandrin, and nozzle for injection of contrast medium suitable for guide wire ERCP-catheter,

Cytology-& Cleaning-

brushes

Endoscopic instrumentsand accessories

8

Page 107: MTW.pdf · ERCP-catheter, reusable All ERCP-catheters with mandrin, and nozzle for injection of contrast medium suitable for guide wire ERCP-catheter,

1

Aus

gabe

2-0

4.04

Cleaning-brushes

DescriptionLength(cm)

Cleaning-brushes, reusable

08 03 10 1 3 160 Ø metal spring 1,8 mm

08 03 20 1 3 230

08 04 10 1 4 160

08 04 20 1 4 230

08 05 10 1 5 160

08 05 20 1 5 230

08 06 10 1 6 160

08 06 20 1 6 230

Article-no. Diameterbrush (mm)

Page 108: MTW.pdf · ERCP-catheter, reusable All ERCP-catheters with mandrin, and nozzle for injection of contrast medium suitable for guide wire ERCP-catheter,

2

Double-cleaning-brush

Description

08 03 10 2 3 160 Ø metal spring 1,8 mm

08 03 20 2 3 230

08 04 10 2 4 160

08 04 20 2 4 230

08 05 10 2 5 160

08 05 20 2 5 230

08 06 10 2 6 160

08 06 20 2 6 230

Cleaning-brushes, reusable

Article-no. Diameterbrush (mm)

Length(cm)

Page 109: MTW.pdf · ERCP-catheter, reusable All ERCP-catheters with mandrin, and nozzle for injection of contrast medium suitable for guide wire ERCP-catheter,

3

Aus

gabe

2-0

4.04

Cleaning-brushes

DescriptionArticle-no.

08 43 05 0 3 1,6 100

08 43 15 0 3 1,6 180

08 43 25 0 3 1,6 230

08 45 15 0 5 2,0 180

08 45 25 0 5 2,0 230

Double-cleaning-brushes

DescriptionLength(cm)

Article-no. Diameterbrush (mm)

08 43 15 2 3 1,6 180

08 43 25 2 3 1,6 230

08 45 15 2 5 2,0 180

08 45 25 2 5 2,0 230

All disposable cleaning-brushes are delivered in packaging units.

Cleaning-brushes, disposable

2

Diameterbrush (mm)

Length(cm)

Packaging unit:20 pieces

Packaging unit:20 pieces

Diameter (mm)

Diameter(mm)

Page 110: MTW.pdf · ERCP-catheter, reusable All ERCP-catheters with mandrin, and nozzle for injection of contrast medium suitable for guide wire ERCP-catheter,

4

Cytology-brushes, reusable

Article-no.

Cytology-brushes

DescriptionLength(cm)

08 12 10 1 2,5 1,8 160 Ø Teflon tube 1,8 mm

08 12 20 1 2,5 1,8 230 Ø Teflon tube 1,8 mm

08 23 10 1 3,0 2,0 160 Ø Teflon tube 2,2 mm

08 23 20 1 3,0 2,0 230 Ø Teflon tube 2,2 mm

Diameterbrush (mm)

Diameterball (mm)

Page 111: MTW.pdf · ERCP-catheter, reusable All ERCP-catheters with mandrin, and nozzle for injection of contrast medium suitable for guide wire ERCP-catheter,

Cytology-brushes

Description

Cytology-brushes, disposable

2

All disposable cleaning-brushes are delivered in packaging units.

08 32 01 1 2,5 1,8 120 Broncho

08 33 11 1 3,0 2,2 160 Gastro

08 33 21 1 3,0 2,2 220 Colo

Length(cm)

Diametercatheter (mm)

Article-no. Diameterbrush (mm)

Packaging unit:10 pieces

Page 112: MTW.pdf · ERCP-catheter, reusable All ERCP-catheters with mandrin, and nozzle for injection of contrast medium suitable for guide wire ERCP-catheter,

Sclerosing-needles& Needles for

fibrinadhesive-injection

Endoscopic instrumentsand accessories

9

Page 113: MTW.pdf · ERCP-catheter, reusable All ERCP-catheters with mandrin, and nozzle for injection of contrast medium suitable for guide wire ERCP-catheter,

1

Aus

gabe

2-0

4.04

Sclerosing-needles, reusable

Article-no. Description

Sclerosing-needles, Teflon

Handle, one hand usage

Diametercannula (mm)

09 10 51 82 18 1,8 0,5 180

09 10 71 82 18 1,8 0,7 180

09 10 71 82 23 2,3 0,7 180

09 10 72 32 23 2,3 0,7 230

09 11 01 82 23 2,3 1,0 180

09 11 02 32 23 2,3 1,0 230

09 11 21 82 23 2,3 1,2 180

09 11 22 32 23 2,3 1,2 230

5 mm

Length(cm)

Diameter(mm)

Page 114: MTW.pdf · ERCP-catheter, reusable All ERCP-catheters with mandrin, and nozzle for injection of contrast medium suitable for guide wire ERCP-catheter,

2

Sclerosing-needles, reusable

Sclerosing-needles, Teflon

09 10 71 85 23 2,3 0,7 180

09 10 72 35 23 2,3 0,7 230

Handle with nozzle on the sideto wash-out

Sclerosing-needles, metal

09 10 51 81 18 1,8 0,5 180

09 10 71 81 23 2,3 0,7 180

09 10 72 31 23 2,3 0,7 230

09 11 01 81 23 2,3 1,0 180

09 11 02 31 23 2,3 1,0 230

Handle, one hand usage

5 mm

5 mm

Article-no. DescriptionDiametercannula (mm)

Length(cm)

Diameter(mm)

Article-no. DescriptionDiametercannula (mm)

Length(cm)

Diameter(mm)

Page 115: MTW.pdf · ERCP-catheter, reusable All ERCP-catheters with mandrin, and nozzle for injection of contrast medium suitable for guide wire ERCP-catheter,
Page 116: MTW.pdf · ERCP-catheter, reusable All ERCP-catheters with mandrin, and nozzle for injection of contrast medium suitable for guide wire ERCP-catheter,
Page 117: MTW.pdf · ERCP-catheter, reusable All ERCP-catheters with mandrin, and nozzle for injection of contrast medium suitable for guide wire ERCP-catheter,

5

Aus

gabe

2-0

4.04

Sclerosing-needles, two-way for fibrinadhesive-injection

09 25 51 64 26 2,6 0,5 / 0,5 160

09 27 51 64 26 2,6 0,5 / 0,7 160

09 27 71 64 26 2,6 0,7 / 0,7 160

09 27 51 84 26 2,6 0,5 / 0,7 180

09 27 71 84 26 2,6 0,7 / 0,7 180

09 25 52 34 26 2,6 0,5 / 0,5 230

09 27 52 34 26 2,6 0,5 / 0,7 230

09 27 72 34 26 2,6 0,7 / 0,7 230

Handle

6 mm

Sclerosing-needles, two-way, reusable

Article-no. DescriptionDiametercannula (mm)

Length(cm)

Diameter(mm)

Page 118: MTW.pdf · ERCP-catheter, reusable All ERCP-catheters with mandrin, and nozzle for injection of contrast medium suitable for guide wire ERCP-catheter,

6

Sclerosing-needles, two-way for fibrinadhesive-injection

99 09 27 51 64 26 2,6 0,5 / 0,7 160

99 09 27 71 64 26 2,6 0,7 / 0,7 160

99 09 27 51 84 26 2,6 0,5 / 0,7 180

99 09 27 71 84 26 2,6 0,7 / 0,7 180

99 09 27 52 34 26 2,6 0,5 / 0,7 230

99 09 27 72 34 26 2,6 0,7 / 0,7 230

Handle

26

mm

All disposable fibrin-needles are delivered in packaging units.

Sclerosing-needles, two-way, disposable

Article-no. DescriptionDiametercannula (mm)

Length(cm)

Diameter(mm)

Packaging unit:2 pieces

Page 119: MTW.pdf · ERCP-catheter, reusable All ERCP-catheters with mandrin, and nozzle for injection of contrast medium suitable for guide wire ERCP-catheter,
Page 120: MTW.pdf · ERCP-catheter, reusable All ERCP-catheters with mandrin, and nozzle for injection of contrast medium suitable for guide wire ERCP-catheter,

8

Biopsy-cannula, reusable

Semi-flexible bronchoscope-cannula

09 21 00 81 21 2,1 1,0 80

Handle

12 mm

Article-no. DescriptionDiametercannula (mm)

Length(cm)

Diameter(mm)

Page 121: MTW.pdf · ERCP-catheter, reusable All ERCP-catheters with mandrin, and nozzle for injection of contrast medium suitable for guide wire ERCP-catheter,

Accessories

Endoscopic instrumentsand accessories

10

Page 122: MTW.pdf · ERCP-catheter, reusable All ERCP-catheters with mandrin, and nozzle for injection of contrast medium suitable for guide wire ERCP-catheter,
Page 123: MTW.pdf · ERCP-catheter, reusable All ERCP-catheters with mandrin, and nozzle for injection of contrast medium suitable for guide wire ERCP-catheter,
Page 124: MTW.pdf · ERCP-catheter, reusable All ERCP-catheters with mandrin, and nozzle for injection of contrast medium suitable for guide wire ERCP-catheter,

Foreign body protector hood

Article-no. Description

10 02 00 7 A soft rubber hood to be used on distal end of mostendoscopes in order to protect the cardiac sphincter,oesophagus and pharynx during removal of a foreign bodyvia the endoscopic tract.

Balloon for ultrasonic-endoscopeArticle-no. Description

Accessories, disposable

2

10 70 1 Echo-hood, model Olympus, 2 openings

10 70 2 Echo-hood, model Olympus, 2 openings

10 70 3 Echo-hood, model Pentax, 1 opening

10 70 4 Echo-hood, model Olympus, 1 opening

Packaging unit:20 pieces

Page 125: MTW.pdf · ERCP-catheter, reusable All ERCP-catheters with mandrin, and nozzle for injection of contrast medium suitable for guide wire ERCP-catheter,
Page 126: MTW.pdf · ERCP-catheter, reusable All ERCP-catheters with mandrin, and nozzle for injection of contrast medium suitable for guide wire ERCP-catheter,
Page 127: MTW.pdf · ERCP-catheter, reusable All ERCP-catheters with mandrin, and nozzle for injection of contrast medium suitable for guide wire ERCP-catheter,

Aus

gabe

2-0

4.04

Accessories, reusable

Clip for instruments

Article-no. Description

00 20 0The clips for instruments are manufactured with high-qualitysurgical steel and therefore

- guaranteed stainless- autoclavable by 134° C- extremely durable

The clips for instruments are the solution of:- safekeeping of your guide wires and flexible accessories

The clips for instruments prevent from tangling of guide wiresand are suitable for all diameters of guide wires and accessorieslike ERCP-catheters and polypectomy snares.

Minimum order qty.: 25 pieces

Stopper for handleArticle-no. Description

00 10 0 the stoppers are to be used

- for effective reprocessing of biopsy- and foreign-body removingforceps

- as tension stopper to avoid too strong bending for example withpapillotomes

By putting on the stopper at the handle of forceps it is ensuredthat the spoons at the distal end will stay open during repro-cessing and no blood or tissue particles adhere at the spoons.Minimum order quantity 25 pieces"

Page 128: MTW.pdf · ERCP-catheter, reusable All ERCP-catheters with mandrin, and nozzle for injection of contrast medium suitable for guide wire ERCP-catheter,
Page 129: MTW.pdf · ERCP-catheter, reusable All ERCP-catheters with mandrin, and nozzle for injection of contrast medium suitable for guide wire ERCP-catheter,

Bronchoscope-instruments

Endoscopic instrumentsand accessories

11

Page 130: MTW.pdf · ERCP-catheter, reusable All ERCP-catheters with mandrin, and nozzle for injection of contrast medium suitable for guide wire ERCP-catheter,

1

Aus

gabe

2-0

4.04

Biopsy-forceps, reusable

Biopsy-forceps, round spoonshaped mouth, without spike

11 06 11 01 00 1,0 120

11 06 14 11 10 1,8 120 tapered

11 06 15 11 10 2,2 120 tapered

Biopsy-forceps, round spoonshaped mouth, with spike

11 06 15 11 11 2,2 120 tapered

Handle, standard

PTFE-coating and nozzle on the side to wash-out is possible by request

Handle used forPTFE-coatedforceps

Article-no. DescriptionLength(cm)

Diameter(mm)

Article-no. DescriptionLength(cm)

Diameter(mm)

Stopper for handle to be used for reprocessing, chapter 6, page 11 and chapter 10, page 9

Page 131: MTW.pdf · ERCP-catheter, reusable All ERCP-catheters with mandrin, and nozzle for injection of contrast medium suitable for guide wire ERCP-catheter,

2

Biopsy-forceps, reusable

Biopsy-forceps, oval spoonshaped mouth, without spike

11 06 11 02 00 1,0 120

11 06 14 02 10 1,8 120 fenestrated, tapered

11 06 15 02 10 2,2 120 fenestrated, tapered

Biopsy-forceps, oval spoonshaped mouth, with spike

11 06 14 02 11 1,8 120 fenestrated, tapered

Handle, standard

PTFE-coating and nozzle on the side to wash-out is possible by request

Handle used forPTFE-coatedforceps

Article-no. DescriptionLength(cm)

Diameter(mm)

Article-no. DescriptionLength(cm)

Diameter(mm)

Stopper for handle to be used for reprocessing, chapter 6, page 11 and chapter 10, page 9

Page 132: MTW.pdf · ERCP-catheter, reusable All ERCP-catheters with mandrin, and nozzle for injection of contrast medium suitable for guide wire ERCP-catheter,

3

Aus

gabe

2-0

4.04

Biopsy-forceps and foreign-body removingforceps, reusable

Biopsy-forceps, alligator jaws

11 06 11 03 00 1,0 120

Foreign-body removing forceps, alligator jaws

11 07 10 7 1,8 120 tapered

11 07 20 7 2,2 120 tapered

Handle, standard

PTFE-coating and nozzle on the side to wash-out is possible by request

Handle used forPTFE-coatedforceps

Article-no. DescriptionLength(cm)

Diameter(mm)

Article-no. DescriptionLength(cm)

Diameter(mm)

Stopper for handle to be used for reprocessing, chapter 6, page 11 and chapter 10, page 9

Page 133: MTW.pdf · ERCP-catheter, reusable All ERCP-catheters with mandrin, and nozzle for injection of contrast medium suitable for guide wire ERCP-catheter,

4

Foreign-body removing forceps, reusable

Foreign-body removing forceps, metal

Foreign-body removing forceps, rat-tooth

11 07 10 6 1,8 120

Handle, standard

x

11 07 10 1 1,8 120 30 3-arm

Handle, standard

PTFE-coating and nozzle on the side to wash-out is possible by request

Handle used forPTFE-coatedforceps

Article-no. Diameter (mm)

DescriptionLength(cm)

Opening-width

(X=mm)

Article-no. DescriptionLength(cm)

Diameter(mm)

Stopper for handle to be used for reprocessing, chapter 6, page 11 and chapter 10, page 9

Page 134: MTW.pdf · ERCP-catheter, reusable All ERCP-catheters with mandrin, and nozzle for injection of contrast medium suitable for guide wire ERCP-catheter,

5

Aus

gabe

2-0

4.04

Lithotomy baskets, reusable

X

y

X

y

Lithotomy basket

11 12 45 90 4 35/50 1,3 120

Lithotomy basket

11 03 11 23 04 15/25 1,8 120

Handle with nozzle forinjection of contrast medium

DescriptionArticle-no. X/Y Diameter (mm) (mm)

Length(cm)

DescriptionArticle-no. X/Y Diameter (mm) (mm)

Length(cm)

Page 135: MTW.pdf · ERCP-catheter, reusable All ERCP-catheters with mandrin, and nozzle for injection of contrast medium suitable for guide wire ERCP-catheter,

6

Lithotomy baskets, reusable

Lithotomy baskets

y

x11 03 11 21 04 10/20 1,8 120

11 03 11 31 04 10/20 2,3 120

11 03 11 33 04 15/25 2,3 120

Lithotomy baskets, 6 wires

11 03 11 34 06 20/30 2,3 120

11 03 11 36 06 30/45 2,3 120

X

Y

Handle with nozzle forinjection of contrast medium

DescriptionArticle-no. X/Y Diameter (mm) (mm)

Length(cm)

DescriptionArticle-no. X/Y Diameter (mm) (mm)

Length(cm)

Page 136: MTW.pdf · ERCP-catheter, reusable All ERCP-catheters with mandrin, and nozzle for injection of contrast medium suitable for guide wire ERCP-catheter,

7

Aus

gabe

2-0

4.04

Aspiration-needles, reusable

Aspiration-needles, teflon

11 09 10 72 18 1,8 0,7 120 model „a“

11 09 11 01 23 2,3 1,0 120 model „a“

12 m

m

Handle, one hand usage

Article-no. Description

11 09 10 71 18 1,8 0,7 120 model „b“

11 09 10 71 23 2,3 1,0 120 model „b“

12 m

m

model „a“ model „b“

Aspiration-needles, metal

Aspiration-needle, disposable

09 10 71 22 16 1,8 0,7 120

10 m

m

2

Length(cm)

Diameter(mm)

Diametercannula (mm)

Article-no. DescriptionLength(cm)

Diameter(mm)

Diametercannula (mm)

Article-no. DescriptionLength(cm)

Diameter(mm)

Diametercannula (mm)

Packaging unit:5 pieces

Page 137: MTW.pdf · ERCP-catheter, reusable All ERCP-catheters with mandrin, and nozzle for injection of contrast medium suitable for guide wire ERCP-catheter,

8

Biopsy-cannula, reusable

Flexible biopsy-cannula for bronchoscopy

09 20 71 22 18 1,8 0,7 120 12

09 21 01 22 23 2,3 1,0 120 12

Handle

x

09 21 00 81 21 2,1 1,0 80

12 m

m

Coated metalspring

Article-no. DescriptionDiametercannula (mm)

Length(cm)

Diameter(mm)

X(mm)

Semi-flexible bronchoscope-cannula

Article-no. DescriptionDiametercannula (mm)

Length(cm)

Diameter(mm)

Page 138: MTW.pdf · ERCP-catheter, reusable All ERCP-catheters with mandrin, and nozzle for injection of contrast medium suitable for guide wire ERCP-catheter,

Cytology-brushes, reusable

Cytology-brushArticle-no.

11 08 12 01 1,8 1,8 120

11 08 23 01 2,2 2,0 120

Description

13 m

m

Length(cm)

Ø brush: 3,0 mm,brush-length 13 mm

Ø brush: 2,5 mm,brush-length 13 mm

Diameter (mm)

Diameterball (mm)

Page 139: MTW.pdf · ERCP-catheter, reusable All ERCP-catheters with mandrin, and nozzle for injection of contrast medium suitable for guide wire ERCP-catheter,

1

Aus

gabe

2-0

4.04

Cytology-brushes, disposable

Cytology-brushes

2

All disposable cytology-brushes are delivered in packaging units.

08 32 01 1 2,5 1,8 120 brush-length 10 mm

10 m

m

DescriptionLength(cm)

Diametercatheter (mm)

Article-no. Diameterbrush (mm)

Packaging unit:10 pieces

Page 140: MTW.pdf · ERCP-catheter, reusable All ERCP-catheters with mandrin, and nozzle for injection of contrast medium suitable for guide wire ERCP-catheter,

1

Double-cleaning-brush

11 08 04 02 4,0 130

11 08 06 02 6,0 130

Cleaning-brushes, reusable

DescriptionArticle-no. Diameterbrush (mm)

Length(cm)

Page 141: MTW.pdf · ERCP-catheter, reusable All ERCP-catheters with mandrin, and nozzle for injection of contrast medium suitable for guide wire ERCP-catheter,

1

Aus

gabe

2-0

4.04

Cleaning-brushes

08 43 05 0 3 100

08 43 15 0 3 180

08 43 25 0 3 230

08 45 15 0 5 160

08 45 25 0 5 230

08 43 15 2 3 180

08 43 25 2 3 230

08 45 15 2 5 180

08 45 25 2 5 230

All disposable cleaning-brushes are delivered in packaging units.

Cleaning-brushes, disposable

2

DescriptionArticle-no. Diameterbrush (mm)

Length(cm)

Packaging unit:20 pieces

Double-cleaning-brushes

DescriptionLength(cm)

Article-no. Diameterbrush (mm)

Packaging unit:20 pieces

Page 142: MTW.pdf · ERCP-catheter, reusable All ERCP-catheters with mandrin, and nozzle for injection of contrast medium suitable for guide wire ERCP-catheter,

1

Ballooncatheter, disposable

Ballooncatheter for the bronchoscopy

Article-no. Diameter (Ch.)

11 03 20 51 20 5 100 x = 12 mm

11 03 20 72 30 7 100 x = 16 mm

Description

2

xLength

(cm)

Page 143: MTW.pdf · ERCP-catheter, reusable All ERCP-catheters with mandrin, and nozzle for injection of contrast medium suitable for guide wire ERCP-catheter,

1

Aus

gabe

2-0

4.04

Symmetrical snare, reusable

Symmetrical polypectomy snare, twisted wire

11 12 24 59 0 1,5 120 15 / 20

Y

X

Handle with a nozzle onthe side to wash-out

Article-no. Diameter (mm)

Length(cm)

DescriptionOpening-width X/Y

(mm)

Page 144: MTW.pdf · ERCP-catheter, reusable All ERCP-catheters with mandrin, and nozzle for injection of contrast medium suitable for guide wire ERCP-catheter,

1

Wash-out-/Spray-catheter, reusable

Wash-out-catheterArticle-no. Diameter

(mm)

11 01 20 10 0 1,6 120

11 01 30 90 0 2,3 120

11 31 01 21 0 2,3 120

11 21 01 21 3 1,6 120

11 31 01 21 3 2,3 120

Description

SpraycatheterArticle-no. Diameter

(mm)

11 01 01 21 0 1,8 120

11 01 01 31 0 2,3 120

Description

Length(cm)

Length(cm)

(a) (b) (c)

with color markings (a)

with color markings(a)

with metal head and color markings (b)

with metal head (c)

with metal head (c)

Page 145: MTW.pdf · ERCP-catheter, reusable All ERCP-catheters with mandrin, and nozzle for injection of contrast medium suitable for guide wire ERCP-catheter,

Guide wires

Endoscopic instrumentsand accessories

12

Page 146: MTW.pdf · ERCP-catheter, reusable All ERCP-catheters with mandrin, and nozzle for injection of contrast medium suitable for guide wire ERCP-catheter,

1

Aus

gabe

2-0

4.04

Article-no. Diameter(inch)

Guide wires, reusable

Kink resistant guide wire NITINOL®

Length(cm)

00 18 00 0.018 400 blue-black

Description

Article-no. Diameter(inch)

Kink resistant guide wire NITINOL®

00 22 00 0.025 400 green-black

Description

NITINOL® is a registered trademark

50 mm Platinum tip

50 mm Platinum tip

Length(cm)

Page 147: MTW.pdf · ERCP-catheter, reusable All ERCP-catheters with mandrin, and nozzle for injection of contrast medium suitable for guide wire ERCP-catheter,

2

Article-no. Diameter(inch)

Guide wires, reusable

Kink resistant guide wire NITINOL®

00 32 26 0.035 260 yellow-black

00 32 00 0.035 400 yellow-black

Description

Article-no. Diameter(inch)

Kink resistant guide wire NITINOL®

soft-tip

Description

00 34 00 0.035 400 yellow-blue,with soft-tip

NITINOL® is a registered trademark

50 mm Platinum tip

Length(cm)

Length(cm)

50 mm Platinum tip

Page 148: MTW.pdf · ERCP-catheter, reusable All ERCP-catheters with mandrin, and nozzle for injection of contrast medium suitable for guide wire ERCP-catheter,

3

Aus

gabe

2-0

4.04

Article-no. Diameter(inch)

Guide wires, reusable

Kink resistant guide wire NITINOL®

J-wire

Description

Article-no. Diameter(inch)

Kink resistant guide wire NITINOL®

J-soft-tip

Description

00 36 00 0.035 400 yellow-blue,J-wire,with soft-tip

00 35 00 0.035 400 yellow-black,J-wire

NITINOL® is a registered trademark

50 mm Platinum tip

50 mm Platinum tip

Length(cm)

Length(cm)

Page 149: MTW.pdf · ERCP-catheter, reusable All ERCP-catheters with mandrin, and nozzle for injection of contrast medium suitable for guide wire ERCP-catheter,

4

Article-no. Diameter(inch)

Guide wire, disposable

Kink resistant guide wire NITINOL®

00 37 00 0.035 400 yellow-black, hydrophilic

coated

Description

2

NITINOL® is a registered trademark

Length(cm)

50 mm Platinum tip

300 mm hydrophilic coated

Page 150: MTW.pdf · ERCP-catheter, reusable All ERCP-catheters with mandrin, and nozzle for injection of contrast medium suitable for guide wire ERCP-catheter,

5

Aus

gabe

2-0

4.04

Article-no. Diameter(inch)

Guide wires, reusable

Kink resistant guide wire NITINOL®

00 23 00 0.025 460 black-white

00 33 00 0.035 460 black-white

Description

Article-no. Diameter(inch)

Guide wire, model Seldinger

Description

00 21 00 0.025 400 flexible tip, length 50 mm

00 35 30 0.035 300 flexible tip, length 10 mm

00 31 00 0.035 400 flexible tip, length 50 mm

NITINOL® is a registered trademark

50 mm Platinum tip

Length(cm)

Length(cm)

Page 151: MTW.pdf · ERCP-catheter, reusable All ERCP-catheters with mandrin, and nozzle for injection of contrast medium suitable for guide wire ERCP-catheter,

6

Article-no. Diameter(inch)

Guide wires, reusable

Guide wire, model Eder-Püstow

00 17 21 5 0.057 215 flexible tip, length 60 mm

00 17 35 0 0.057 350 flexible tip, length 60 mm

Description

Article-no. Diameter(inch)

00 38 00 0.035 400 flexible tip

Description

Kink resistant guide wire NITINOL®

with scale

NITINOL® is a registered trademark

50 mm Platinum tip

Length(cm)

Length(cm)