Multi F Outdoor Units
Multi F multi-zone comfort solutions are air-conditioning systems that “split” into indoor and outdoor units, providing a smart alternative to both central HVAC and window-mounted air conditioners. These Inverter heat pump systems are available in f�{fwnjy~�tk�htsŅlzwfyntsx�yt�xzny�inkkjwjsy�httqnsl�fsi�mjfynsl�xnyzfyntsx/�
Multi F SystemsLG’s Inverter heat pumps can support two, three, or up to four indoor units that are typically installed in separate rooms. Indoor units include a remote control, and many styles are offered: Art Cool™ Mirror wall-mounted, Art Cool Gallery™ wall- mounted, standard wall-mounted, four-way ceiling cassettes, ceiling-concealed duct (high and low static), and vertical-horizontal air handling models.
Adaptable and FlexibleMulti F outdoor units can be used on a wide range of building applications: schools, hotels, hospitals, tkŅhjx0�htsitrnsnzr0�fsi�xnslqj�kfrnq~�wjxnijshjx/�
Smaller Piping Lengths and PlenumsLG Multi F systems use refrigerant piping to move heat, resulting in smaller space requirements for piping. Flexible and logical placement of system components, reduced back-and-forth pipe lengths, and fewer connections lowers installation and materials costs.
Quality CommitmentLG is committed to the success of air-conditioning projects. We provide technical support during installation, and offer a variety of classes designed for installers and xjw{nhj�uwt{nijwx/��Nqfxxjx�fwj�htsizhyji�fy�WR>x�ywfnsnsl�hjsyjwx�fsi�ns�Ņjqi� locations at various times throughout the year and upon special request.
Benefits of Multi F SystemsA�Individual zone controlA�Long refrigerant piping lengthsA�Large refrigerant piping elevation
differencesA�Maximum flexibilityA�Operating ranges of 14°F to 118°F in
cooling and 0°F to 64°F in heatingA�Quiet and comfortable
environmentA�Safer and easier installation with
reduced ductwork A�Cost efficientA�Lightweight and compact system
components
MULTI FAbout LG Electronics, Inc.LG Electronics, Inc. is a global leader and technology innovator in consumer electronics, mobile communi-cations, and home appliances, employing more than 213,000 people in more than 60 countries worldwide. LG’s commercial air conditioning business unit was established in 1968, and offers VRF, Multi F, duct-free split systems, packaged terminal air conditioners (PTACs), and room air conditioners.
With LG, it’s all possible.™
Multi F Dual
Tri, and Quad
Zone
FeaturesA�Defrost / deicingA�Restart delay (three [3] minutes)A�Self diagnosis ; Soft start
A�Inverter (Variable speed compressor)A�Auto / auto restart operation
A�Low ambient operation to 14°F (Cool-ing mode)A�Gold Fin™ anti-corrosion
LMU187HV15,600 Btu/h Cooling17,000 Btu/h Heating
LMU247HV19,200 Btu/h Cooling26,400 Btu/h Heating
LMU369HV34,000 Btu/h Cooling41,000 Btu/h Heating
bfwwfsy~5�_|t�"D-�~jfwx�ufwyx6�Ņ{j�"G-�~jfwx�htruwjxxtw/
Ozj�yt�tzw�utqnh~�tk�htsynsztzx�uwtizhy�nsst{fynts0�xtrj�xujhnŅhfyntsx�rf~�hmfslj�|nymtzy�stynŅhfynts/� ©LG Electronics U.S.A., Inc., Englewood Cliffs, NJ. All rights reserved. “LG” is a registered trademark of LG Corp.
Dual-ZoneLMU187HV
Quad-Zone LMU369HV
Tri-ZoneLMU247HV
Model Number LMU187HV LMU247HV LMU369HVRated Cooling Capacity (Btu/h) 15,600 19,200 34,000
Rated Heating Capacity (Btu/h) 17,000 26,400 41,000
Power InputCooling (kW) 1.12 1.43 2.72
Heating (kW) 1.29 2.21 3.58
Running CurrentCooling (A) 5.2 6.6 11.8
Heating (A) 6.0 10.2 15.5
Power Supply (Phase / V / Hz) 1 / 208~230 / 60 1 / 208~230 / 60 1 / 208~230 / 60
Power Wiring / Communication Cable (No. x AWG) 4 x 18 4 x 18 4 x 18
Dimensions (W x H x D) (in.) 34-1/4 x 31-13/16 x 12-19/32 34-1/4 x 31-13/16 x 12-19/32 35-7/16 x 45-7/8 x 14-9/16
Net Unit Weight (lbs.) 124 131 199
Min. / Max. Number Indoor Units / System 2 / 2 2 / 3 2 / 4
RefrigerantFactory Charge (lbs.) 4.19 4.63 7.72
Type / Control / Location R410A / EEV / Outdoor Unit R410A / EEV / Outdoor Unit R410A / EEV / Outdoor Unit
Sound Pressure Level Cooling / Heating (dB[A]) 51 51 57
Piping ConnectionsLiquid (in., OD) x Qty. 1/4 x 2 1/4 x 3 1/4 x 4
Vapor (in., OD) x Qty. 3/8 x 2 3/8 x 3 3/8 x 4
Max. Total Piping (ft)5 164 246.1 246.1
Max. Outdoor Unit to Indoor Unit Piping (ft.) 82 82 82
Piping Length (No Additional Refrigerant [ft.]) 49.2 73.8 98.4
Max. ElevationDifference
Outdoor ~ Indoor (ft.) 49.2 49.2 49.2
Indoor ~ Indoor (ft.) 24.6 24.6 24.6
Operation RangeCooling (°F DB) 14 - 118 14 - 118 14 - 118
Heating (°F WB) 0 - 64 0 - 64 0 - 64
DFS-PB-AJ-008-US 013M18
System Indoor Unit Combo. Nominal Cooling (Btu/h) EER SEER Nominal Heating (Btu/h) COP HSPF Low Heating (Btu/h) COP Energy Star
LMU187HVNon-Ducted 15,600 14.0 21.0 17,000 3.9 9.2 10,000 2.9 Yes
Ducted 14,800 11.9 17.7 16,800 3.8 8.8 9,900 2.8 -Ducted & Non-Ducted 15,200 12.95 19.35 16,900 3.9 9.0 9,950 2.8 -
LMU247HVNon-Ducted 19,200 13.4 21.7 26,400 3.5 9.4 16,200 2.6 Yes
Ducted 18,000 11.8 16.4 26,200 3.4 8.5 16,400 2.6 -Ducted & Non-Ducted 18,600 12.6 19.05 26,300 3.5 8.95 16,300 2.6 -
LMU369HVNon-Ducted 34,000 12.5 17.5 41,000 3.4 10.5 26,000 2.4 Yes
Ducted 34,000 12.0 16.5 41,000 3.2 9.5 27,400 2.6 -Ducted & Non-Ducted 34,000 12.25 17.0 41,000 3.3 10.0 26,700 2.5 -
PkŅhnjsh~�]fynslx
Multi F Multi Zone System Outdoor Units
Date:
Job�Name/Location:
PO�No.:
Architect:Engr:
GC:
Rep:
For: File
Approval
Mech:
Resubmit
Other
Tag�#:
(Company) (Project�Manager)
Multi�F�Inverter�Heat�Pump�Outdoor�Unit
DFSͲSBͲADͲ019ͲUS�013J27
Performance:
LMU187HV
Nominal�Cooling�Capacity�(Btu/h) 18,000Cooling�Power�Input�(kW) 1.12Heating�Power�Input�(kW) 1.29Cooling�Nominal�Test�Conditions: Heating�Nominal�Test�Conditions:Indoor: 80°F�DB/67°F�WB Indoor: 70°F�DB/60°F�WBOutdoor: 95°F�DB/75°F�WB Outdoor: 47°F�DB/43°F�WB
Electrical:Power�Supply�(V¹/Hz/Ø) 208Ͳ230/60/1MOP�(A) 15MCA�(A) 11.0Cooling�Rated�Amps�(A) 11.4Heating�Rated�Amps�(A) 11.9Compressor�(A) 8.2Fan�Motor�(A) 0.40
Piping:
Refrigerant�Charge�(lbs) 4.19Liquid�Line�(in,�OD) 1/4�(2�Each)Vapor�Line��(in,�OD) 3/8�(2�Each)Max�Total�Piping�(ft)² 164.0
Max�Elevation�between�ODU�and�IDU�(ft) 49.2Max�Elevation�between�IDU�and�IDU�(ft) 24.6
Controls�Features: •Auto�operaƟon� •Auto�restart�operaƟon •Defrost/Deicing •Inverter�(variable�speed�compressor)
•Low�ambient�operaƟon�to�14F�(cooling�mode) •Restart�delay�(3Ͳminutes) •Self�diagnosis •SoŌ�start
Operating�Range:Cooling�(°F�DB) 14Ͳ118Heating�(°F�WB) 0Ͳ64
Unit�Data:
Refrigerant�Type R410ARefrigerant�Control EEVSound�Pressure³�(Cool/Heat)�±3�dB(A) 51/51Net�Unit�Weight�(lbs) 124Shipping�Weight�(lbs) 133Heat�Exchanger�Coating GoldFin™
Max�Number�of�Indoor�Units 2
Compressor:
Quantity 1Type TwinͲRotary�InverterOil/Type FVC68D
Fan:
Type PropellerQuantity 1Fan�Motor/Drive Brushless�Digitally�Controlled/DirectAirflow�Rate�(CFM) 2,119
Notes: 1.Acceptable�operaƟng�voltage:�187VͲ253V. 2.Piping�lengths�are�equivalent. 3.Sound�Pressure�levels�are�tested�in�an�anechoic�chamber�under�ISO�Standard�1996. 4.All�power/communicaƟon�cable�to�be�minimum�18�AWG,�4Ͳconductor,�stranded,�
shielded�and�must�comply�with�applicable�local�and�national�code. 5.Power�wiring�cable�size�must�comply�with�the�applicable�local�and�naƟonal�code. 6.See�Engineering�Manual�for�sensible�and�latent�capaciƟes. 7.Power�wiring�cable�size�must�comply�with�the�applicable�local�and�naƟonal�code. 8.This�data�is�rated�0�Ō�above�sea�level,�with�24.6�Ō�of�refrigerant�line�and�a�0�Ō�level�
difference�between�outdoor�and�indoor�units.��All�capacities�are�net�with�a�combination�ratio�between�95�–�105%.
9.Refer�to�the�Engineering�Product�Data�Book�for�combinaƟon�capacity�tables. 10.The�outdoor�unit�combined�with�nonͲducted�indoor�units�qualifies�for�Energy�Star. 11.Must�follow�installaƟon�instrucƟons�in�the�applicable�LG�installaƟon�manual.
1�of�4
Max�ODU�to�IDU�Piping�(ft) 82.0Piping�Length�(no�add'l�refrigerant,�ft) 49.2
Min�Number�of�Indoor�Units 2
For�continual�product�development,�LG�reserves�the�right�to�change�specifications�without�notice.LG�Electronics�U.S.A.,�Inc.,�Englewood�Cliffs,�NJ.�All�rights�reserved.�“LG�Life’s�Good”�is�a�registered�trademark�of�LG�Corp.�/www.lghvac.com
Optional�Accessories:PIͲ485�Integration�Board�Ͳ�PMNFP14A0AC�Smart�Premium�Ͳ�PQCSW421E0AAC�Ez�Ͳ�PQCSZ250S0
MOP�Ͳ�Maximum�Overcurrent�Protection MCA�Ͳ�Minimum�Circuit�Ampacity
ODU�Ͳ�Outdoor�Unit IDU�Ͳ�Indoor�Unit
Power�Distribution�Indicator�Ͳ�PQNUD1S00
Job�Name/Location:
Tag�#:Date:PO�No.:
Multi�F�Inverter�Heat�Pump�Outdoor�Unit
DFSͲSBͲADͲ019ͲUS�013J27
LMU187HV
2�of�4For�continual�product�development,�LG�reserves�the�right�to�change�specifications�without�notice.LG�Electronics�U.S.A.,�Inc.,�Englewood�Cliffs,�NJ.�All�rights�reserved.�“LG�Life’s�Good”�is�a�registered�trademark�of�LG�Corp.�/www.lghvac.com
Job�Name/Location:
Tag�#:Date:PO�No.:
Flex�Multi�Inverter�Heat�Pump�Outdoor�UnitLMU187HV
Capacity��data�is�based�on�the�following�conditions�–�Cooling�Nominal�Test�Conditions: Heating�Nominal�Test�Conditions:Indoor: 80°F�DB/67°F�WB Indoor: 70°F�DB/60°F�WBOutdoor: 95°F�DB/75°F�WB Outdoor: 47°F�DB/43°F�WB
Refer�to�the�EPDB�Capacity�Tables�for�capacities�at�other�temperatures.
Page�3�of�4DFSͲSBͲADͲ019ͲUS�013A08For�continual�product�development,�LG�reserves�the�right�to�change�specifications�without�notice.LG�Electronics�U.S.A.,�Inc.,�Englewood�Cliffs,�NJ.�All�rights�reserved.�“LG�Life’s�Good”�is�a�registered�trademark�of�LG�Corp.�/www.lghvac.com
Job�Name/Location:
Tag�#:Date:PO�No.:
Flex�Multi�Inverter�Heat�Pump�Outdoor�UnitLMU187HV
Page�4�of�4DFSͲSBͲADͲ019ͲUS�013A08For�continual�product�development,�LG�reserves�the�right�to�change�specifications�without�notice.LG�Electronics�U.S.A.,�Inc.,�Englewood�Cliffs,�NJ.�All�rights�reserved.�“LG�Life’s�Good”�is�a�registered�trademark�of�LG�Corp.�/www.lghvac.com
Capacity��data�is�based�on�the�following�conditions�–�Cooling�Nominal�Test�Conditions: Heating�Nominal�Test�Conditions:Indoor: 80°F�DB/67°F�WB Indoor: 70°F�DB/60°F�WBOutdoor: 95°F�DB/75°F�WB Outdoor: 47°F�DB/43°F�WB
Refer�to�the�EPDB�Capacity�Tables�for�capacities�at�other�temperatures.
Date:
Job�Name/Location:
PO�No.:
Architect:Engr:
GC:
Rep:
For: File
Approval
Mech:
Resubmit
Other
Tag�#:
(Company) (Project�Manager)
Multi�F�Inverter�Heat�Pump�Outdoor�Unit
DFSͲSBͲADͲ017ͲUS�013M12
Performance:
LMU247HV
Nominal�Cooling�Capacity�(Btu/h) 24,000Cooling�Power�Input�(kW) 1.43Heating�Power�Input�(kW) 2.21Cooling�Nominal�Test�Conditions: Heating�Nominal�Test�Conditions:Indoor: 80°F�DB/67°F�WB Indoor: 70°F�DB/60°F�WBOutdoor: 95°F�DB/75°F�WB Outdoor: 47°F�DB/43°F�WB
Electrical:Power�Supply�(V¹/Hz/Ø) 208Ͳ230/60/1MOP�(A) 25MCA�(A) 15.4Cooling�Rated�Amps�(A) 14.9Heating�Rated�Amps�(A) 14.9Compressor�(A) 11.6Fan�Motor�(A) 0.40
Piping:
Refrigerant�Charge�(lbs) 4.63Liquid�Line�(in,�OD) 1/4�(3�Each)Vapor�Line��(in,�OD) 3/8�(3�Each)Max�Total�Piping�(ft)² 246.1
Max�Elevation�between�ODU�and�IDU�(ft) 49.2Max�Elevation�between�IDU�and�IDU�(ft) 24.6
Controls�Features: •Auto�operaƟon� •Auto�restart�operaƟon •Defrost/Deicing •Inverter�(variable�speed�compressor)
•Low�ambient�operaƟon�to�14F�(cooling�mode) •Restart�delay�(3Ͳminutes) •Self�diagnosis •SoŌ�start
Operating�Range:Cooling�(°F�DB) 14Ͳ118Heating�(°F�WB) 0Ͳ64
Unit�Data:
Refrigerant�Type R410ARefrigerant�Control EEVSound�Pressure³�(Cool/Heat)�±3�dB(A) 51/51Net�Unit�Weight�(lbs) 131Shipping�Weight�(lbs) 139Heat�Exchanger�Coating GoldFin™
Max�Number�of�Indoor�Units 3
Compressor:
Quantity 1Type TwinͲRotary�InverterOil/Type FVC68D
Fan:
Type PropellerQuantity 1Fan�Motor/Drive Brushless�Digitally�Controlled/DirectAirflow�Rate�(CFM) 2,119
Notes: 1.Acceptable�operaƟng�voltage:�187VͲ253V. 2.Piping�lengths�are�equivalent. 3.Sound�Pressure�levels�are�tested�in�an�anechoic�chamber�under�ISO�Standard�1996. 4.All�power/communicaƟon�cable�to�be�minimum�18�AWG,�4Ͳconductor,�stranded,�
shielded�and�must�comply�with�applicable�local�and�national�code. 5.Power�wiring�cable�size�must�comply�with�the�applicable�local�and�naƟonal�code. 6.See�Engineering�Manual�for�sensible�and�latent�capaciƟes. 7.Power�wiring�cable�size�must�comply�with�the�applicable�local�and�naƟonal�code. 8.This�data�is�rated�0�Ō�above�sea�level,�with�24.6�Ō�of�refrigerant�line�and�a�0�Ō�level�
difference�between�outdoor�and�indoor�units.��All�capacities�are�net�with�a�combination�ratio�between�95�–�105%.
9.Refer�to�the�Engineering�Product�Data�Book�for�combinaƟon�capacity�tables. 10.The�outdoor�unit�combined�with�nonͲducted�indoor�units�qualifies�for�Energy�Star. 11.Must�follow�installaƟon�instrucƟons�in�the�applicable�LG�installaƟon�manual.
1�of�4
Max�ODU�to�IDU�Piping�(ft) 82.0Piping�Length�(no�add'l�refrigerant,�ft) 73.8
Min�Number�of�Indoor�Units 2
For�continual�product�development,�LG�reserves�the�right�to�change�specifications�without�notice.LG�Electronics�U.S.A.,�Inc.,�Englewood�Cliffs,�NJ.�All�rights�reserved.�“LG�Life’s�Good”�is�a�registered�trademark�of�LG�Corp.�/www.lghvac.com
Optional�Accessories:PIͲ485�Integration�Board�Ͳ�PMNFP14A0AC�Smart�Premium�Ͳ�PQCSW421E0AAC�Ez�Ͳ�PQCSZ250S0
MOP�Ͳ�Maximum�Overcurrent�Protection MCA�Ͳ�Minimum�Circuit�Ampacity
ODU�Ͳ�Outdoor�Unit IDU�Ͳ�Indoor�Unit
Power�Distribution�Indicator�Ͳ�PQNUD1S00
Job�Name/Location:
Tag�#:Date:PO�No.:
Multi�F�Inverter�Heat�Pump�Outdoor�Unit
DFSͲSBͲADͲ017ͲUS�013M12
LMU247HV
2�of�4For�continual�product�development,�LG�reserves�the�right�to�change�specifications�without�notice.LG�Electronics�U.S.A.,�Inc.,�Englewood�Cliffs,�NJ.�All�rights�reserved.�“LG�Life’s�Good”�is�a�registered�trademark�of�LG�Corp.�/www.lghvac.com
Job�Name/Location:
Tag�#:Date:PO�No.:
Flex�Multi�Inverter�Heat�Pump�Outdoor�UnitLMU247HV
Capacity��data�is�based�on�the�following�conditions�–�Cooling�Nominal�Test�Conditions: Heating�Nominal�Test�Conditions:Indoor: 80°F�DB/67°F�WB Indoor: 70°F�DB/60°F�WBOutdoor: 5°F�DB/75°F�WB Outdoor: 47°F�DB/43°F�WB
Refer�to�the�EPDB�Capacity�Tables�for�capacities�at�other�temperatures.
Page�3�of�4DFSͲSBͲADͲ017ͲUS�013M12For�continual�product�development,�LG�reserves�the�right�to�change�specifications�without�notice.LG�Electronics�U.S.A.,�Inc.,�Englewood�Cliffs,�NJ.�All�rights�reserved.�“LG�Life’s�Good”�is�a�registered�trademark�of�LG�Corp.�/www.lghvac.com
Job�Name/Location:
Tag�#:Date:PO�No.:
Flex�Multi�Inverter�Heat�Pump�Outdoor�UnitLMU247HV
Page�4�of�4DFSͲSBͲADͲ017ͲUS�013M12For�continual�product�development,�LG�reserves�the�right�to�change�specifications�without�notice.LG�Electronics�U.S.A.,�Inc.,�Englewood�Cliffs,�NJ.�All�rights�reserved.�“LG�Life’s�Good”�is�a�registered�trademark�of�LG�Corp.�/www.lghvac.com
Capacity��data�is�based�on�the�following�conditions�–�Cooling�Nominal�Test�Conditions: Heating�Nominal�Test�Conditions:Indoor: 80°F�DB/67°F�WB Indoor: 70°F�DB/60°F�WBOutdoor: 5°F�DB/75°F�WB Outdoor: 47°F�DB/43°F�WB
Refer�to�the�EPDB�Capacity�Tables�for�capacities�at�other�temperatures.
Date:
Job�Name/Location:
PO�No.:
Architect:Engr:
GC:
Rep:
For: File
Approval
Mech:
Resubmit
Other
Tag�#:
(Company) (Project�Manager)
Multi�F�Inverter�Heat�Pump�Outdoor�Unit
DFSͲSBͲADͲ004ͲUS�013J27
Performance:
LMU369HV
Nominal�Cooling�Capacity�(Btu/h) 36,000Cooling�Power�Input�(kW) 2.72Heating�Power�Input�(kW) 3.58Cooling�Nominal�Test�Conditions: Heating�Nominal�Test�Conditions:Indoor: 80°F�DB/67°F�WB Indoor: 70°F�DB/60°F�WBOutdoor: 95°F�DB/75°F�WB Outdoor: 47°F�DB/43°F�WB
Electrical:Power�Supply�(V¹/Hz/Ø) 208Ͳ230/60/1MOP�(A) 25MCA�(A) 16.8Cooling�Rated�Amps�(A) 18.6Heating�Rated�Amps�(A) 19.0Compressor�(A) 12.1Fan�Motor�(A) 1.1
Piping:
Refrigerant�Charge�(lbs) 7.72Liquid�Line�(in,�OD) 1/4�(4�Each)Vapor�Line��(in,�OD) 3/8�(4�Each)Max�Total�Piping�(ft)² 246.1
Max�Elevation�between�ODU�and�IDU�(ft) 49.2Max�Elevation�between�IDU�and�IDU�(ft) 24.6
Controls�Features: •Auto�operaƟon� •Auto�restart�operaƟon •Defrost/Deicing •Inverter�(variable�speed�compressor)
•Low�ambient�operaƟon�to�14F�(cooling�mode) •Restart�delay�(3Ͳminutes) •Self�diagnosis •SoŌ�start
Operating�Range:Cooling�(°F�DB) 14Ͳ118Heating�(°F�WB) 0Ͳ64
Unit�Data:
Refrigerant�Type R410ARefrigerant�Control EEVSound�Pressure³�(Cool/Heat)�±3�dB(A) 57/57Net�Unit�Weight�(lbs) 199Shipping�Weight�(lbs) 217Heat�Exchanger�Coating GoldFin™
Max�Number�of�Indoor�Units 4
Compressor:
Quantity 1Type TwinͲRotary�InverterOil/Type FVC68D
Fan:
Type PropellerQuantity 2Fan�Motor/Drive Brushless�Digitally�Controlled/DirectAirflow�Rate�(CFM) 2,119
Notes:
Max�ODU�to�IDU�Piping�(ft) 82.0Piping�Length�(no�add'l�refrigerant,�ft) 98.4
1.Acceptable�operaƟng�voltage:�187VͲ253V. 2.Piping�lengths�are�equivalent. 3.Sound�Pressure�levels�are�tested�in�an�anechoic�chamber�under�ISO�Standard�1996. 4.All�power/communicaƟon�cable�to�be�minimum�18�AWG,�4Ͳconductor,�stranded,�
shielded�and�must�comply�with�applicable�local�and�national�code. 5.Power�wiring�cable�size�must�comply�with�the�applicable�local�and�naƟonal�code. 6.See�Engineering�Manual�for�sensible�and�latent�capaciƟes. 7.Power�wiring�cable�size�must�comply�with�the�applicable�local�and�naƟonal�code. 8.This�data�is�rated�0�Ō�above�sea�level,�with�24.6�Ō�of�refrigerant�line�and�a�0�Ō�level�
difference�between�outdoor�and�indoor�units.��All�capacities�are�net�with�a�combination�ratio�between�95�–�105%.
9.Refer�to�the�Engineering�Product�Data�Book�for�combinaƟon�capacity�tables. 10.The�outdoor�unit�combined�with�nonͲducted�indoor�units�qualifies�for�Energy�Star. 11.Must�follow�installaƟon�instrucƟons�in�the�applicable�LG�installaƟon�manual.
Min�Number�of�Indoor�Units 2
For�continual�product�development,�LG�reserves�the�right�to�change�specifications�without�notice.LG�Electronics�U.S.A.,�Inc.,�Englewood�Cliffs,�NJ.�All�rights�reserved.�“LG�Life’s�Good”�is�a�registered�trademark�of�LG�Corp.�/www.lghvac.com
Optional�Accessories:PIͲ485�Integration�Board�Ͳ�PMNFP14A0AC�Smart�Premium�Ͳ�PQCSW421E0AAC�Ez�Ͳ�PQCSZ250S0
MOP�Ͳ�Maximum�Overcurrent�Protection MCA�Ͳ�Minimum�Circuit�Ampacity
ODU�Ͳ�Outdoor�Unit IDU�Ͳ�Indoor�Unit
Page�1�of�5
Power�Distribution�Indicator�Ͳ�PQNUD1S00
Job�Name/Location:
Tag�#:Date:PO�No.:
Multi�F�Inverter�Heat�Pump�Outdoor�Unit
DFSͲSBͲADͲ004ͲUS�013J27
LMU369HV
For�continual�product�development,�LG�reserves�the�right�to�change�specifications�without�notice.LG�Electronics�U.S.A.,�Inc.,�Englewood�Cliffs,�NJ.�All�rights�reserved.�“LG�Life’s�Good”�is�a�registered�trademark�of�LG�Corp.�/www.lghvac.com Page�2�of�5
Job�Name/Location:
Tag�#:Date:PO�No.:
Multi�F�Inverter�Heat�Pump�Outdoor�UnitLMU369HV
Capacity��data�is�based�on�the�following�conditions�–�Cooling�Nominal�Test�Conditions: Heating�Nominal�Test�Conditions:Indoor: 80°F�DB/67°F�WB Indoor: 70°F�DB/60°F�WBOutdoor: 95°F�DB/75°F�WB Outdoor: 47°F�DB/43°F�WB
Refer�to�the�EPDB�Capacity�Tables�for�capacities�at�other�temperatures.
DFSͲSBͲADͲ004ͲUS�013J27For�continual�product�development,�LG�reserves�the�right�to�change�specifications�without�notice.LG�Electronics�U.S.A.,�Inc.,�Englewood�Cliffs,�NJ.�All�rights�reserved.�“LG�Life’s�Good”�is�a�registered�trademark�of�LG�Corp.�/www.lghvac.com Page�3�of�5
Job�Name/Location:
Tag�#:Date:PO�No.:
Multi�F�Inverter�Heat�Pump�Outdoor�UnitLMU369HV
Capacity��data�is�based�on�the�following�conditions�–�Cooling�Nominal�Test�Conditions: Heating�Nominal�Test�Conditions:Indoor: 80°F�DB/67°F�WB Indoor: 70°F�DB/60°F�WBOutdoor: 95°F�DB/75°F�WB Outdoor: 47°F�DB/43°F�WB
Refer�to�the�EPDB�Capacity�Tables�for�capacities�at�other�temperatures.
DFSͲSBͲADͲ004ͲUS�013J27For�continual�product�development,�LG�reserves�the�right�to�change�specifications�without�notice.LG�Electronics�U.S.A.,�Inc.,�Englewood�Cliffs,�NJ.�All�rights�reserved.�“LG�Life’s�Good”�is�a�registered�trademark�of�LG�Corp.�/www.lghvac.com Page�4�of�5