8
573 Digital Metering g Multilin Digital Energy High-performance power quality and revenue class metering for critical power applications EN50160 flicker with up to 512 waveform samples per cycle and high-speed transient recording for complete power quality monitoring Fast response time to power quality events for diagnostics and maintenance Built-in GPS clock sync capability for accurate time stamping of events and alarms for complete synchronized system monitoring Exceeds ANSI C-12 and IEC 687 specifications for accuracy with auto calibration using temperature compensation Software and hardware triggers record waveform events. This allows the unit to be used for fault analysis, system apparatus monitoring and many other applications Records THD to the 255th order peak. Real-time harmonic magnitudes analysis to the 128th order for every channel. This advanced harmonic recording capability has been traditionally available only in high-end power quality recorders Real time phasor analyzer monitors phase angles between the voltage and the currents Communication option of 10/100 BaseT ethernet with Modbus/ TCP Expandable output modules Revenue class metering and load aggregation for energy management Transformer loss compensation High-performance power quality monitoring of critical loads Current, voltage, real and reactive power, energy use, cost of power, power factor and frequency Laboratory grade 0.04% Watt-Hour accuracy Flicker and waveform recording Real-time PQ monitoring and harmonic magnitude analysis to 255th order Monitoring and Metering Protection and Control Fully programmable set-points for alarms and 90 millisec relay activation for high-speed updates and control Expandable external outputs for control FEATURES FEATURES APPLICATIONS KEY BENEFITS Communications On-board ethernet and Modbus/TCP capability High-speed RS-485 and RS-232 Com Ports Multiple protocols including Modbus and DNP 3.0 level 2 Built-in modem with dial-out capability 8 built-in High-Speed Digital Inputs Multiple analog, digital, and relay outputs Web Server & Gateway EPM 9000 Multilin™ POWER QUALITY METER SERIES High Performance Power Quality Analysis Device
Transcript
Page 1: Multilin™ EPM 9000 - GE Grid Solutions...The EPM 9000 Series meters utilize two separate logs of historical information. Universal Power Supply 3 Communication Ports Heartbeat (Test

573

Dig

ital M

eter

ing

g MultilinDigital Energy

• High-performancepowerqualityandrevenueclassmeteringforcriticalpowerapplications

• EN50160flickerwithupto512waveformsamplespercycleandhigh-speedtransientrecordingforcompletepowerqualitymonitoring

• Fastresponsetimetopowerqualityeventsfordiagnosticsandmaintenance

• Built-inGPSclocksynccapabilityforaccuratetimestampingofeventsandalarmsforcompletesynchronizedsystemmonitoring

• ExceedsANSIC-12andIEC687specificationsforaccuracywithautocalibrationusingtemperaturecompensation

• Softwareandhardwaretriggersrecordwaveformevents.Thisallowstheunittobeusedforfaultanalysis,systemapparatusmonitoringandmanyotherapplications

• RecordsTHDtothe255thorderpeak.Real-timeharmonicmagnitudesanalysistothe128thorderforeverychannel.Thisadvancedharmonicrecordingcapabilityhasbeentraditionallyavailableonlyinhigh-endpowerqualityrecorders

• Realtimephasoranalyzermonitorsphaseanglesbetweenthevoltageandthecurrents

• Communicationoptionof10/100BaseTethernetwithModbus/TCP

• Expandableoutputmodules

• Revenueclassmeteringandloadaggregationforenergymanagement

• Transformerlosscompensation

• High-performancepowerqualitymonitoringofcriticalloads

• Current,voltage,realandreactivepower,energyuse,costofpower,powerfactorandfrequency

• Laboratorygrade0.04%Watt-Houraccuracy• Flickerandwaveformrecording• Real-timePQmonitoringandharmonicmagnitudeanalysis

to255thorder

Monitoring and MeteringProtection and Control• Fullyprogrammableset-pointsforalarmsand90

millisecrelayactivationforhigh-speedupdatesandcontrol

• Expandableexternaloutputsforcontrol

FEATURESFEATURES

APPLICATIONS

KEY BENEFITS

Communications• On-boardethernetandModbus/TCPcapability• High-speedRS-485andRS-232ComPorts• MultipleprotocolsincludingModbusandDNP3.0level2• Built-inmodemwithdial-outcapability• 8built-inHigh-SpeedDigitalInputs• Multipleanalog,digital,andrelayoutputs• WebServer&Gateway

EPM 9000Multilin™

POWER QUALITY METER SERIES

HighPerformancePowerQualityAnalysisDevice

Page 2: Multilin™ EPM 9000 - GE Grid Solutions...The EPM 9000 Series meters utilize two separate logs of historical information. Universal Power Supply 3 Communication Ports Heartbeat (Test

574

EPM 9000 Series:Power Quality MeterD

igita

l Met

erin

g

www.GEDigitalEnergy.com

Standard FeaturesPerfect for industrial, commercial andutility applications, the performanceenhanced EPM 9000, includes all theattributes required for the highest levelof PQ analysis and communications.Fromtoday’sutilitygiantstoFortune100companies to localelectricalmunicipals,an effective energy management andpower-monitoringprogram is critical forsuccess. The EPM 9000 is an advancedmonitoring product , providing the totalpictureofpowerusageandpowerqualityfor any metered point within a powerdistribution network allowing users tomakepowerrelateddecisionsquicklyandeffectively.

Robust Communication

FourIsolatedHigh-speedCommunicationPorts: EPM 9000 offers four built-incommunication ports. Each port cancommunicate independently usingsupportedprotocols. StandardprotocolsincludeModbus RTU/ASCII andDNP 3.0.LogsandwaveformeventsareavailableinModbusformat.Port3andPort4canbe used as aModbus slave for externaloutputmodules.8Built-inDigitalHighSpeedStatusInputs:Theseinputsautomaticallysensewhetherthecircuitisexternallywetted.Ifexternallywetted,theinputwillacceptupto400VDC.If internallywetted, theunit supplies theneeded voltage for the desired controlapplication.High Speed-Transducer Outputs forControl Purposes: EPM 9000 offers 50millisec updates for all instantaneousreadings. The unit can be a high-speedcontrol transducerforpowergeneration,transmission line synchronization andothercontrolschemes.

Precision Power Quality Measurement

16-bitWaveformandFaultRecorder:EPM9000 captures up to 512 samples percycle for an event . Voltage and currentare recorded with pre-and-post-eventanalysis.Hardwareandsoftwaretriggersare available to activate a waveformreading, which can be used for powerquality surveys, fault analysis, breakertiming,motorstart-up,etc.MeasureandRecordHarmonicsMagnitudeto the 255th Order: Measure harmonics

magnitudeuptothe255thorderforeachvoltage and current channel. Real-timeharmonicsmagnitudeareresolvedtothe128th order. Percent THD and K-factorarealsocalculated.Harmonicmagnitudeanalysis allows users to conduct powerquality analysis at the high end of theharmonicspectrum.Sub-Cycle Transient Recorder: The unitrecords sub-cycle transients on voltageandcurrentreadings.Itmonitorsswitchingnoise from capacitors, static transferswitches, SCRs and many other “power

quality harmful” devices. Transientsare often the cause of intermittent andexpensive downtime, and may causedamagetoelectricalequipment.Phasor Analysis: The monitor readsa phase angle analysis between thevoltageandcurrentchannels,allowingforefficiencyandsystem-integrityanalysis.Inter-harmonics Analysis: The EPM 9000provides users with the ability to viewinter-harmonics,thediscretefrequenciesthat lie between the harmonics of thepower frequency voltage and current .

TCP/IP Bus—InternetorIntranet

Multiple socket Internet or Intranet meter access up to 12 sockets simultaneously

INTERNET PACKAGE

LOCAL PC SCADA CONTROL SCHEME

OTHER USERS

EachUserisOneSocketConnection

OtherModbusIEDs

Laptop

ModbusOutputModbus

Multiple Communication Paths

EnerVista Viewpoint Monitoring waveform viewer for analyzing fault data

DNP3.0

Page 3: Multilin™ EPM 9000 - GE Grid Solutions...The EPM 9000 Series meters utilize two separate logs of historical information. Universal Power Supply 3 Communication Ports Heartbeat (Test

575

EPM 9000 Series:Power Quality Meter

Dig

ital M

eter

ing

www.GEDigitalEnergy.com

Frequencies can now be observedwhicharenotan integermultipleof thefundamental.

Revenue Metering

AccuracyinBillingMeasurements:Dual16BitA/Dconvertersprovidesupremesampling accuracy and resolution. Theunit far exceeds ANSI C-12 and IEC 687accuracystandardsoffering0.04%watt-houraccuracy.To ensure optimum accuracy the unitauto-adjusts to dual internal referencesaccurateto1partpermillion.Inaddition,

• Predictivewindow

Time of use (TOU) Capability: EPM 9000offers comprehensive time of usecapability.Standardfeaturesinclude:

• Bi-directionalconsumptionanddemandquantities

• 20-yearcalendar-4seasons/yr,12holidays/yr

• 4TOUschedules/seasons

• Priormonth,priorseasonstorage

• Presentmonth,presentseasonstorage

Transformer Loss and Line LossCompensation:Theunitcompensatesfortransformerandlinelosses.Powerreadingcompensation isconductedforboth ironandcopperlosses.Load Aggregation/Universal Metering:Using the status inputs, EPM 9000 hastheabilitytocountpulsesandaggregatedifferent loads providing a total pictureoftheloadanditscomponentparts.Thiscanbeusedtoaccumulateandaggregateotherutilitiessuchaswaterandgasdata.

Multiple Programmable Memory Logs

The EPM 9000 Seriesmeters utilize twoseparate logs of historical information.

UniversalPowerSupply

3CommunicationPorts

Heartbeat(TestPulse)

RS-232

4VoltageInputs 4CurrentInputs

IRIG-BInput

8High-SpeedStatusInputs

RuggedMetalCase

On-Board ModemorEthernetTCP/IP

User Interface

the EPM 9000 uses an auto-calibrationtechnique that recalibrates the unit onthe fly when the temperature changesmorethan5degreesCelsiusforimprovedaccuracyoverthefulltemperaturerange.Max/Min Integration and Recording:The unit offers time stamped max andminvaluesforeverymeasuredreading.kWreadingsareintegratedusing:

• Block(fixed)window

• Thermalwindow

• Rolling(sliding)window

EnerVista Viewpoint Monitoring harmonic spectrum graph to quantify power quality

Page 4: Multilin™ EPM 9000 - GE Grid Solutions...The EPM 9000 Series meters utilize two separate logs of historical information. Universal Power Supply 3 Communication Ports Heartbeat (Test

576

EPM 9000 Series:Power Quality MeterD

igita

l Met

erin

g

www.GEDigitalEnergy.com

History can be used for trending andconducting preventive maintenance...Conduct preventative maintenanceon critical equipment as well as poweranalysis.

Primary Historical Tending Log File - Log 1

Loganymeasuredparameterfromeitherthemainunitoranyoftheoptionmodules.Either8,16,32or64valuescanbeloggedperprogrammableinterval.

Secondary Historical Tending Log File - Log 2

This log can be set up as an additionalhistorical interval log or as an exclusiveenergylog.Either8,16,32or64valuescanbeloggedperinterval.

Out Of Limit Log

Theunitsofferanindependentoutoflimitlog.Thisallowsausertodownloadoutoflimit informationtoobtainasequenceofeventsforanyoccurrence.Utilizingthe1millisecclock resolution, the logscanbecombined with differentmetered pointsthroughadistribution system toprovidean accurate system-wide depiction of apowerdisturbance.

Event-Triggered Waveform Recording Log

EPM 9000 records waveforms with aresolutionofupto512samplespercycle.Theamountofwaveformrecordingisbasedontheamountofmemoryinstalled.The unit records the waveform when avaluegoesoutoflimitandwhenthevaluereturns tonormal.All information is timestamped to thenearest1millisec. The8on-boardhigh-speedinputscanbetiedtothewaveformrecording.Recordwhenthebreakertrippedascomparedtowhentherelayactivated.Thisisveryusefulforfaultandbreakerintegrityanalysis.The unit can be programmed to takemore than one recording every time aneventoccurs.Thousandsofcyclescanberecordedperevent.

Optional Features

Flicker (EPM 9650 only)

EN50160 Flicker and ComplianceMonitoring: Flicker consists of lowfrequency(lessthan24Hz)tointermittentlinedisturbancesonthepowerline.Flickercan affect equipment . The EPM 9650complieswiththeFlickerrequirementsofEN50160thatincludesharmonics.

Modem

Dial-Out on Alarm: With the built-inoptional modem, the meter providesdial-out capabilities that can detect analarmoccurrenceanddialsouttoprovidenotification.

Dial-Out for other Events

Themeter candial-out for the followingcircumstances:

• Limitstatuschange

• High-speedinputchange

• Waveformrecordcapture

• CBEMApowerqualityevent

• Controloutputchange

• Fillingofmetermemory

• Cyclingofcontrolpower

• Passwordfailureonacallcomingintothemodem

• Metercommunicationfailure

Dial-In Server Capabilities

The dial-in server will record allnotificationsandacceptdownloadsfromthemeter.

Ethernet Capability

TheEPM9000seriesmeterhasanoptionalEthernetthatsupportsModbus/TCP.

Output Modules

GEMultilinoffersmultipleanaloganddigitaloutputmodulesthatmountexternallytotheEPM9000.Theunitsupportsupto4outputmodulesusing internalpower.Anadditional power supply extends outputcapability. The unit can poll differentoutput devices, logdata, and senddatatoamasterstationviaModbusorDNP3.0protocol.The EPM 9000 power monitor providesadvanced logic and control onprogrammablelimitsettings.

EnerVista Viewpoint Monitoring - Access real-time system values and track energy consumption

Page 5: Multilin™ EPM 9000 - GE Grid Solutions...The EPM 9000 Series meters utilize two separate logs of historical information. Universal Power Supply 3 Communication Ports Heartbeat (Test

577

EPM 9000 Series:Power Quality Meter

Dig

ital M

eter

ing

www.GEDigitalEnergy.com

EnerVistaTM Software

EnerVistaTM Launchpad

EnerVistaTM Launchpad is a powerfulsoftware package that provides users aplatform to access all of the setup andsupport tools needed for configuringand maintaining GE Multilin Products.Launchpad allows configuration ofdevices in real-time by communicatingusingRS232,RS485,Ethernet,ormodemconnections.UsingLaunchpadas the single interfacetothesetupandanalysissoftwaremakesitsimpletoentersetpoints,readmeteredvalues,monitorstatusandevaluatepowerquality.Powerfultroubleshootingfeaturesmakeiteasytoretrieveandviewvoltage& current waveshapes and harmonicanalysis. This vital information can helpprovide early warning of problems andprevent equipment damageor nuisancebreakertripping.

EnerVista Viewpoint Monitoring - Monitor the status of digital inputs and review the magnitude of system highs and lows

Included in Launchpad is a documentarchiving and management systemthat ensures critical documentation isup-to-date and available when neededby automatically checking for anddownloading new versions of manuals,applications nates, specifications, andservicebulletins.

Viewpoint Monitoring

Viewpointmonitoring is a simple-to-use,full-featuredmonitoringanddatarecordingsoftware package for small systems.ViewpointMonitoringprovidesacompleteHMI package that instantly puts criticalreal-timedevicedataonyourPCthroughpre-configuredgraphicalscreenswiththefollowingfunctionality:

• Plug-&-PlayDeviceMonitoring

• SystemSingle-LineMonitoring&Control

• AnnunciatorAlarmScreens

• TrendingReports

• AutomaticEventRetrieval

• AutomaticWaveformRetrieval

EnerVistaTM Integrator

EnerVistaTM Integrator is a toolkit thatallowsseamless integrationofGEMultilindevices into new or existing automationsystems by sending GE device data toHMI,DCS,andSCADAsystems.IncludedinEnverVistaIntegratoris:

• OPC/DDEServer

• GEMultilinDrivers

• AutomaticEventRetrieval

• AutomaticWaveformRetrieval

Page 6: Multilin™ EPM 9000 - GE Grid Solutions...The EPM 9000 Series meters utilize two separate logs of historical information. Universal Power Supply 3 Communication Ports Heartbeat (Test

578

EPM 9000 Series:Power Quality MeterD

igita

l Met

erin

g

www.GEDigitalEnergy.com

External Output Modules

Touch screen LCD display

Multifunction LED Display

Typical Wiring

VbCHASISL+ N- Vref.Vaux. Va Vc HIIa

LO

Ib

LO

HI HIIc

LO

HIIn

LO

HI

LO LO LO

Vref.Vaux.CHASISL+ N- IaVb VcVa Ib HI IcHI

LO

HIIn

LINECTs

SWITCHGEARCHASSISGROUND

LOAD

SWITCHGEARCHASSISGROUND

SUPPLYPOWER(DEPENDENTONEQUIPPEDPOWERSUPPLYOPTION)

4 Wire Wye: 3 Element Direct Voltage

CTs

SUPPLYPOWER(DEPENDENTONEQUIPPEDPOWERSUPPLYOPTION)

B

A

LOADLINE

N

CBA

3 Wire: 3 Element Direct Delta

FUSES0.25AFUSES

0.25A

CTSHORTINGSWITCH

CRTESTBLOCK

CTSHORTINGSWITCH

CRTESTBLOCK

C

Page 7: Multilin™ EPM 9000 - GE Grid Solutions...The EPM 9000 Series meters utilize two separate logs of historical information. Universal Power Supply 3 Communication Ports Heartbeat (Test

579

EPM 9000 Series:Power Quality Meter

Dig

ital M

eter

ing

www.GEDigitalEnergy.com

WAVEFORMSamples No of Cycles **Max. No of Cycles No of per Cycle Record per Screen* Record per Event Channels

16 8Pre/56 6080 7 32 4Pre/28 3040 7 64 4Pre/12 1520 7 128 1Pre/7 760 7 256 1Pre/3 760 3 512 1Pre/3 760 1*PostEventScreen(Calculationsat60Hz.)

*Specifications subject to change without notice.

Technical Specifications

COMMUNICATIONSFormat: ProgrammableparityandstopbitsPorts: 4Communicationports 2slaveportsPort 1: RS-232orRS-485selectableProtocol: Modbus® ModbusASCII/RTUandDNP3.0Media: Allportsuse2-wireRS-485 communicationBaud rate: 56KbpsModem: 56KModemwithdial-outcapabilityEthernet: 10/100baseTwithModbus/TCP ProtocolFunctions: Read/writesetpoints ReadactualvaluesIsolation: AllComPortsareadditionally isolatedfromeachother

ENVIRONMENTALHumidity: Upto95%non-condensingTemperature: -40°Cto+80°Cambient

CONSTRUCTIONConstructedinametalcase.Allhardwareisstainlesssteel.

PACKAGINGShipping box: 16”x13”x11” (40.64cmx33.02cmx27.94cm)Ship weight: approx.12lbs(5.4kgs)

TYPE TESTSType tests as per UL® & CE®

Emissions: EN55011Immunity: EN50082Accuracy Communication : ANSIC12.20Class0.2andIEC687 Isolation: 2500voltsAC60HzVoltage Input withstand: Opticallyisolatedto2500VDCCurrent Input withstand: 100ampsfor10Seconds 300ampsfor1SecondSurge withstand: ANSI/IEEEC37.90.1Surge: ANSIC62.41ESD: IEC1000-4-2Radiated Immunity:IEC1000-4-3Fast Transient: IEC1000-4-4Surge Immunity: IEC1000-4-5Flicker Meter: IEC868Flicker Meter: IEC61000-4-15

APPROVALSISO: ManufacturedtoanISO9001registered programUL & cUL: Recognizedundere200431CE: ConformstoEN55011/EN50082Industry Canada Revenue Metering:Approval:#AE-1069

POWER SUPPLYCONTROL POWERInput options: 90–276VoltsAC/DC 18–60VoltsDCFrequency: 20–400HzBurden: 20VAmax

DISPLAYTOUCH SCREEN LCD DISPLAYTouchscreengraphicaldisplay320x240pixelsCCFLbacklitDisplaysdatafromupto8meters4.7”x3.5”aperture(12.1cmx9.1cm)

LED DISPLAY3-linemulti-functionLEDsRS-485masterDisplaysdatafromasinglemeter

DEMAND MONITORINGMeasured values: PhaseA/B/C/Ncurrent(A) 3phaserealpower(kW) 3phasereactivepower(kvar) 3phaseapparentpower(kVA)Measurement type: Thermalexponential 1–9999sec,stepsof1sec Blockinterval/rollingdemandtimein interval(programmable): 1–9999sec,stepsof1sec

INPUTSINPUT VOLTAGE RANGE 150Vphasetoneutral,300Vphasetophase*300Vphasetoneutral,600Vphasetophase*TobeusedalsowithPTsforextendedinputvoltage.

INPUT CURRENT RANGE5ampinputs2xcontinuousprogrammabletoanyCTrangeFaultcurrentrecordingto60ampspeaksecondarybasedon5ampfullscaleNote: 1ampand0.25ampcurrentinputsavailableasspecialorder

ISOLATIONAllinputsandoutputsareisolatedto2500Volts

FREQUENCY RANGEFundamental45-75Hz

BURDENVoltageinputs:0.05VAMaxCurrentinputs:0.005VAMax

SENSING METHODUpto512samplespercycle(programmable)16BitA/Dresolution–dualconvertersTrueRMS

UPDATE TIME200millesec—highspeedinstantreadings1second—Revenueaccurate

METERINGMEASURED VALUES

MEASUREMENTS 200 Millisec* 1 Sec Display Resolution Voltage (L-N) 0.10% 0.05% 5Digit Voltage (L-L) 0.10% 0.05% 5Digit Current 0.10% 0.025% 5Digit Frequency 0.03Hz 0.01Hz 00.001Hz KW @ Unity PF 0.10% 0.06% 5Digit KW @ .5 PF 0.10% 0.1% 5Digit KVA 0.40% 0.08% 5Digit VAR 0.10% 0.0% 5Digit PF 0.10% 0.08% 3Digit Harmonics N/A 0.2% 3Digit KW/Hours N/A 0.04% 16Digit KVA/Hours N/A 0.08% 16Digit KVAR/Hours N/A 0.08% 16Digit

Note:Readingsareinpercentofreadingwhereapplicable(moreaccuratestandard),notinpercentoffullscale(lessaccuratestandard).

ACCURACY: ANSIC12.20Class0.2andIEC687HARMONICS: Measuresharmonicmagnitudesto the255thorderforeachvoltage andcurrentchannel Real-timeharmonicsresolvedtothe 128thorder

OUTPUT MODULESANALOG TRANSDUCER SIGNAL OUTPUT 4AnalogOutputs,0–1mA,self-powered,scalable,

bi-directional8AnalogOutputs,0–1mA,self-powered,scalable,

bi-directional4AnalogOutputs,4–20mA,self-powered,scalable8AnalogOutputs,4–20mA,self-powered,scalable

Wiring: CommonModeAccuracy: 0.1%ofFullScaleCalibration: Self-CalibratingScaling: ProgrammableOrdering Specifics: Upto4AnalogOutputmodulescan beusedwitheachunit

DIGITAL DRY CONTACT RELAY OUTPUTS4RelayOutputs,5amps,125,AC/DC,FormC

Ordering Specifics: Multiplemodulescanbeused

DIGITAL SOLID STATE PULSE OUTPUTS4SolidStatePulse,Outputs,FormAorCKYZPulses

Maximum Pulse Speed: 20pulsespersecondOrdering Specifics: Upto4modulescanbeusedBUILT-IN DIGITAL INPUTS8DigitalStatusInputsWet/DryAuto-DetectUpto300VoltsDC

DATA LOGGINGEPM 9450Log Storage Options 512K RAM 512K Record Size Historical Log 1 176K 58DaysHistorical Log 2 256K 42DaysOut of Limit 48K 512CBEMA Log 16K 256Relay Output Log N/A N/AInput Status Log N/A N/AWaveform Recording N/A 8Number of Events

Note: HistoricalLog1iscalculatedrecording8valuesevery15minutes.HistoricalLog2iscalculatedstoringallintegratedhourreadingsevery15minutes.Everyreadingforeverylogisrecordedwiththeappropriatetimestamps.

• ViewGuideformSpecifications

• Downloadtheinstructionmanual

• Reviewapplicationsnotesandsupportdocuments

• BuyanEPM9000online

Visit www.GEMultilin.com/EPM9000 to:

EPM 9650Log Storage Options 2 Meg RAM 2 Meg Record Size 4 Meg RAM 4 Meg Record Size Historical Log 1 176K 58Days 1808K 602DaysHistorical Log 2 256K 42Days 400K 66DaysOut of Limit 48K 512 96K 1024CBEMA Log 16K 256 64K 1024Relay Output Log N/A N/A 32K 512Input Status Log N/A N/A 32K 512Waveform RecordingNumber of Events

N/A 8 1568K 96

Page 8: Multilin™ EPM 9000 - GE Grid Solutions...The EPM 9000 Series meters utilize two separate logs of historical information. Universal Power Supply 3 Communication Ports Heartbeat (Test

580

EPM 9000 Series:Power Quality MeterD

igita

l Met

erin

g

www.GEDigitalEnergy.com

PL9000 * * * * 0 0 0 0 0 Digital Output Modules

4 R O 1 4ChannelControlRelayOutputs 4 P O 1 4ChannelkyzSolidStatePulseOutputs

EPM 9450 - Highperformancepowermeter&dataacquisitionnodePL9450 * * * A * 0 0 0 0 Description Frequency 0 60Hz 1 50Hz System Voltage A 120/208voltsconnection B 277/480voltsconnection Control Power 0 90-276voltsAC/DCpowersupply 1 18-60voltsDCpowersupply Features Options A Basicunitwith512Kmemory,8digitalinputs, 8cycleofwaveform(upto512samples/cycle),100daysdatalog. Communications 0 4communicationport User-selectableRS485ModbusandDNP-nomodemorEthernetconnection 1 10/100BaseTEthernet,webserverandgatewaycapability 2 Internal56kmodemconnectionwithpass-throughport

PL9000 * * * * * * * 0 0 Analog Output Modules

1 M A O N 4 O 4Channel0-1mAAnalogOutputs 1 M A O N 8 O 8Channel0-1mAAnalogOutputs 2 O M A O N 4 4Channel4-20mAAnalogOutputs 2 O M A O N 8 8Channel4-20mAAnalogOutputs

PL9000 * * * * 0 0 0 0 0 Digital Input Modules

8 D I 1 0 0 0 0 0 8ChannelDigitalStatusInputs

PL9000 * * * * 0 0 0 0 0 9000 Series Meter Software

N C M 1 CommunicatorSoftware,SingleUserLicense N C M 5 CommunicatorSoftware,FiveUserLicense N C M S CommunicatorSoftware,MultipleUser,SingleSiteLicense

PL9000 * * * * * * * * * 9000 Series Meter Display Module

P 4 0 N P L U S 0 ThreelineLEDDisplay P 6 0 N 0 0 0 0 0 Touch-ScreenLCDDisplaywith6-ftcable P 6 0 N 1 0 0 0 0 Touch-ScreenLCDDisplaywith15-ftcable

PL9650 * * * A * 0 0 0 0 Description Frequency 0 60Hz 1 50Hz System Voltage A 120/208voltsconnection B 277/480voltsconnection Control Power 0 90-276voltsAC/DCpowersupply 1 18-60voltsDCpowersupply Features Options A Advanceunitincludesbasicunit,with2Megmemory, Upto96daysofdatalogging,upto64cyclesofwaveformrecording B FlickerincludesadvanceunitplusFlickerwith4Megmemory,602daysofdatalogging Communications 0 4Communicationports User-selectableRS485ModbusandDNP-nomodemorEthernetconnection 1 10/100BaseTEthernet,webserverandgatewaycapability 2 Internal56kmodemconnectionwithpass-throughport

PL9000 M B I O 0 0 0 0 0 Auxiliary Mounting Bracket (One set per module group)

PL9000 P S I O 0 0 0 0 0 Auxiliary Power Supply (For more than 4 modules)

EPM 9650 - Highperformancepowermeter&dataacquisitionnodewithmemory

Ordering

Accessories

Meters

120412-V7

PL9000 * * * * * * * 0 0 Analog Input Modules

8 A I 1 0 0 0 0 0 8Channel0–1mAAnalogInputs 8 A I 2 0 0 0 0 0 8Channel0–20mAAnalogInputs 8 A I 3 0 0 0 0 0 8Channel0–5VDCAnalogInputs 8 A I 4 0 0 0 0 0 8Channel0–10VDCAnalogInputs


Recommended