CHAPTER-1 INTRODUCTION 1.1 GENERAL Due to the concentration and increase of population into urban cities there is a need to accommodate the influx in the urban cities. However, due to rapid increase of land cost, and limited availability of land the trend is to build high rise building. The advantages of high rise buildings include but not limited to high ratio rentable floor space per unit area of land. These high rise buildings are sky scrapers are built not just for economy of space they are considered icons of a city’s economic power and the city’s identity. Various types of structural system have been used to facilitate the demand of high rise structures. Thousands of high rise buildings are being built all over the world with steel as well as reinforced concrete. Many of the high rise buildings are designed with structural components consisting of various systems such as flat slab, flat plate system, and shear wall core with or without perimeter beams. High rise buildings are used for densely populated areas where mix uses high rise buildings including commercial and residential uses because the systems have various following advantages. High rise buildings are characterized by their high susceptibility to lateral drift under the effect of lateral loads such as wind and earthquake 1
Transcript
Page 1: Multistorey building

CHAPTER-1INTRODUCTION

1.1 GENERAL

Due to the concentration and increase of population into urban cities there is

a need to accommodate the influx in the urban cities. However, due to rapid increase

of land cost, and limited availability of land the trend is to build high rise building.

The advantages of high rise buildings include but not limited to high ratio rentable

floor space per unit area of land. These high rise buildings are sky scrapers are built

not just for economy of space they are considered icons of a city’s economic power

and the city’s identity.

Various types of structural system have been used to facilitate the demand of

high rise structures. Thousands of high rise buildings are being built all over the world

with steel as well as reinforced concrete. Many of the high rise buildings are designed

with structural components consisting of various systems such as flat slab, flat plate

system, and shear wall core with or without perimeter beams. High rise buildings are

used for densely populated areas where mix uses high rise buildings including

commercial and residential uses because the systems have various following

advantages.

High rise buildings are characterized by their high susceptibility to lateral

drift under the effect of lateral loads such as wind and earthquake loads. Providing

shear walls and or knee bracings in the building system greatly helps in improving its

resistance behavior to lateral loads. It may be possible by engaging the perimeter

columns with the shear wall core which will increase the effective depth of structure

participating in lateral load resistance. Outrigger braced tall building structure usually

consists of a stiff central core, connected to the exterior columns by flexural stiff

cantilevers at the outrigger floors and floor members (slab and floor beam) at typical

floors.

Structure: It is a G+5 multistory building with a height of 5 floors 15 m. The

typical floor height is 3.00 m. Area of the building is 207.27 Sqm. The entire columns

size up to 5th floor is 0.45 x 0.55 m. The no. of columns is 20 per each floor. The

columns have been provided at required spacing. Perimeter columns are connected

1

Page 2: Multistorey building

with knee bracings to resist the lateral deflections. The shear walls with a thickness

of 0.15 m are used in resisting the lateral loads.

1.2 LOADING:

Loading on tall buildings is different from low-rise buildings in many ways such

as large accumulation of gravity loads on the floors from top to bottom, increased

significance of wind loading and greater importance of dynamic effects. Thus, multi-

storied structures need correct assessment of loads for safe and economical design.

Excepting dead loads, the assessment of loads cannot be done accurately. Live loads can

be anticipated approximately from a combination of experience and the previous field

observations. But, wind and earthquake loads are random in nature. It is difficult to

predict them exactly. These are estimated based on probabilistic approach. The following

discussion describes the influence of the common loads.

Gravity loads: Dead loads due the weight of every element within the structure and

live loads that are acting on the structure when in service constitute gravity loads. The

dead loads are calculated from the member sizes and estimated material densities.

Live loads prescribed by codes are empirical and conservative based on experience and

accepted practice.

Live loads: Live loads are those loads produced by the use and occupancy of the

building or other structure and do not include construction or environmental loads

such as wind load, snow load, rain load, earthquake load, flood load, or dead load.

Live loads on a roof are those produced (1) during maintenance by workers,

equipment, and materials; and (2) during the life of the structure by movable objects

such as planters and by people.

Lateral loads and resisting systems: The lateral loads from wind and earthquakes

are known as lateral loads and are resisted by a set of steel frames in orthogonal

directions or by reinforced concrete shear walls. Steel frames are broadly classified as

braced-frames and moment-resisting frames depending on the type of configuration

and beam-to-column connection provided.

2

Page 3: Multistorey building

CHAPTER-2

PLANNING OF MULTISTOREY BUILDING

2.1 BASIC AND ARCHITECTURAL PLANNING AND DESIGN

Building: Building is defined as any structure for whatsoever purpose and of

whatsoever materials constructed and every part there of whether used as human

habitation or not and includes Foundation, Plinth walls, Floors, Chimneys, Plumbing

and building services, fixed platforms, Verandah, balcony. Cornice(or projection), and

signs and outdoor display structures. Broadly speaking, building consist of three parts,

namely

(i) Foundation

(ii) Plinth and

(iii) Superstructure.

General principles of site selection: Site selection has an important bearing on

planning and designing of buildings. Generally, therefore an architect has either to

make a choice of suitable site or to plan his building structure to suit the available site.

Natural defects of a site will involve considerable expenditure on construction and

maintenance of the building.

A site which comes within the limits of an area where the by-laws of the local

authority enforce restrictions regarding proportions of plots to built up, vacant

spaces to be left in front and sides, heights of buildings etc. should be preferred.

The site should be situated on an elevated place and also leveled on with uniform

slopes from one end to the other so as to provide good and quick drainage of rain

water.

The soil surface of the site should be good enough to provide economical

foundations for the intended building without causing any problem. Generally for

most satisfactory instructions, the site should have rock, sand or firm soil below

60 to 120cm. layer of light or even black cotton soil.

The situation of the site should be such as to ensure unobstructed natural light and

air.

3

Page 4: Multistorey building

The site should have a good land scape but away from quarries, kilns, factories

etc.

A site should be abandoned under adverse circumstances such as (a) Un healthy,

noisy or crowded localities (b) Immediate neighborhood of rivers carrying heavy

floods, badly maintained drains (c) Reclaimed soil of water-logged areas, subject

to substance or settlement and (d) Industrial having smoke and obnoxious odours.

Fig2.1: Plan and detailing of building

4

Page 5: Multistorey building

2.1.1 ORIENTATION OF A-BUILDING

Orientation is defined as a method of setting or fixing the direction of the plan

of the building in such a way that it derives maximum benefit from elements of nature

such as a sun, wind and rain.

Faulty housing conditions cause poor health and spread of various types of

diseases. Resistance to disease may be increased by living in fresh air and exposing

the body to sunshine. Proper orientation of a house increases fresh air and sunshine in

the house and decrease possibility of direct infection.

FACTORS AFFECTING ORIENTATION:

The factors affecting the orientation of a building are:

Climatic factors solar radiation and wind directions.

Local topography

Pleasure of a view

Requirements of privacy

Reduction of noise

Of the above, climatic factors are more important than all the other factors. For this it

is essential to know the following:

Sun’s path and its relative position with respect to the locality.

The direction of prevalent wind and Intensity and direction of rain.

HELPFUL POINTS REGARDING THE ORIENTATION:

Long walls of building should face North and South, short wall’s should face East

and West.

A verandah or balcony can be provided towards East and West to keep the rooms

cool.

To protect building from sub and rain Chajjas are required for window facing the

east, west and South.

5

Page 6: Multistorey building

2.1.2 COMPONENT PARTS OF A BUILDING:

A building generally consists of the following parts.

Foundations and basement.

Superstructure.

Doors and Windows.

Lintels.

Sun Shades.

Flooring.

Stair Case.

2.1.3 FUNCTIONS OF THE DIFFERENT COMPONENTS:

1. Foundations and basement: The foundation is that parts of the building normally

below the ground level. It receives the Load from the superstructure and uniformly

transmits it to the soil below it. The Strength and stability of a structure depend on the

foundation and hence to be carefully designed.

Basement is that part of the structure which separates the foundation and the

superstructure. The height of the basement decides the level of the flooring in the

building. The top of the basement B called the Plinth.

2. Super structure: This is the part of the wall above the basement. It carries the

superimposed loads from the floors and roof. It performs the following functions.

It supports the floors and roof.

It encloses the space or divides if.

3. Doors and Windows: Doors and Windows are provided in openings in a wall.

Doors enable people to move from in and out of rooms, or building windows provide

free circulation of air control entry of natural light in to the building.

4. Lintels: A Lintel is a horizontal member of RCC stone or Wood placed over an

opening to support the structure above it.

5. Sun shade: A sun shade is a horizontal member projecting from the face of the

wall placed above an opening to prevent sun’s rays or rain entering the room.

Generally there are made of RCC and cast monolithically with an RCC lintel.

6

Page 7: Multistorey building

2.2 FOUNDATION:

A foundation is that part of structure which is indirect contact with the ground. It

transfers the load of the structure to the soil below so as to avoid over loading of the

soil beneath. It prevents the differential settlement by evenly loading the substrata. It

provides a level surface for building operations. It also increases stability of structure

by taking the structure deep into the ground. Foundations are generally built of bricks,

Stones, Concrete and Steel etc. The selection of material and type of foundation

depends upon the type of structure and the nature of underlying soil.

The selection of foundation type suitable for a particular site depends on the following

considerations.

Nature of Sub Soil.

Nature and extent of difficulties, e.g., presence of boulder, buried tree trunks

etc. likely to be meet with.

Availability of expertise and equipment. Depending upon their nature and

depth, foundations have been categorized as follows.

i). Open foundations or shallow foundations.

ii). Deep foundations.

General procedure in Foundation Design:

The following steps should be followed in the design of foundations.

A site investigation should be carried out to determine

o The Physical and Chemical properties of the soil beneath the site.

o To find the position of water table.

o To obtain information on all factors affecting the design of the foundations

and their behavior.

To determine the magnitude and distribution of Loading from the Super Structure.

To determine the total and differential settlements which can be tolerated by the

structure.

To evolve the most suitable type of foundation and its depth below ground level.

7

Page 8: Multistorey building

To determine preliminary values of the allowable bearing pressure appropriate to

the type of foundation.

To calculate the pressure distribution beneath the foundation.

To prepare cost estimates of alternate design.

To select the material for foundation.

To prepare structural designs.

To prepare working designs.

Depth of Foundation:

The foundation of a building should be taken down to such depth, or be so constructed

as to safeguard the building against damage by swelling, shrinkage or freezing of the

subsoil. The foundation should be taken down to a depth where the bearing capacity

of the soil is adequate to support the foundation loading without failure of the soul in

the shear or excessive consolidation of the soil. As far as possible the foundations

should be kept above ground water level in order to avoid the most of pumping, and

possible instability of the soil due to seepage of water into the bottoms of the

excavation. A depth of 0.9 to 1 M. is regarded as a minimum at which some seasonal

movement will occur but is unlikely to be of a magnitude sufficient to cause damage

to the superstructure or ordinary building finishes.

The depth of foundation can also be obtained by plotting the lines of angles

45o and 60o

Let h1 = Depth of footing

h2 = Total depth of foundation

h3 = depth if concrete block

Then h = h1 + h2

To find the minimum depth of foundation of for loose soil, the following

Rankine’s formula can be used.

h = p/w [(1 - Sin Φ) / (1 + Sin Φ)]

Where,

h = Minimum depth of foundation in meters

8

Page 9: Multistorey building

w = Weight of Soil in Kg/m3

Φ = Angle of soil in Kg/m2

2.3 MASONRY:

Superstructure is that portion of the building which above the floor level. Its main

function is to enclose or divide space. It may have to provide support in certain

situations. Masonry is essentially a well material. Broadly, wall can be divided into

following two types.

Load – bearing walls and

Non - load bearing wall or certain wall or filler wall or panel.

The functional requirements of a wall depend upon its form of construction.

The popular form of construction used is

Masonry walls, and

Monolithic walls.

Masonry wall: The wall is built of individual blocks of materials such as stone, brick

concrete, hollow bricks, cellular concrete, laterite etc. usually in horizontal courses

cemented together with some form of mortar. The binding strength of mortar is

usually disregarded as far as the strength of the wall is concerned.

Monolithic Walls: These are the walls built of a material requiring some sort of

shuttering in the initial stages. The popular form of monolithic walls one traditional

earth walls and modern CC and RCC walls.

Masonry Classification: Broadly, Masonry can be classified into following

categories.

Stone Masonry

Brick Masonry

Hollow block concrete masonry

Reinforced Masonry and

Composite Masonry.

9

Page 10: Multistorey building

Stone Masonry: It is the art of building the structures in stones. In some parts if the

country building stones are abundantly available in nature these stones when cut and

dressed to the proper shape provide an economical material for the constructing of

various parts of a building which are located in hilly areas.

Uses of stone Masonry:

Stone Masonry Construction is used in

Building foundations, dams, monumental structures

Building walls, piers, columns, pillars, light houses and architectural works.

Arches, domes, lintel and beams

Roofs, floors, paving jobs and

Railway ballast, blackboards and electrical switch boards.

Brick Masonry: Brick Masonry is a unified mass obtained by systematic

arrangement of laying bricks and bounding together with mortar. Brick is a building

unit of hard inorganic clay material of a size which can be conveniently handled.

They can be easily arranged into various shapes for most of the structure, e.g.,

foundations, walls, columns, buttresses, retaining structures, window sills, jambs

corbels, copings ornamental brick work, circular brick work, fire places, flumes, tall

chimneys, cavity walls, thresholds, culverts, steps, floors, arches etc. The strength of

brick masonry works depends upon the quality of brick and type of mortar used.

Bonds in Brick Masonry: Bonding is a process of arranging bricks and mortars to tie

them together in a mass of brick work.

Wall thickness in brick work: The wall thickness depends upon

The anticipated load to come on the wall

The quality of wall material

The overall height

The spacing between buttresses and cross wall

The different loads which can act on walls are:

Dead weight of the wall

Dead weight due to floor or roof slab or beams etc.

10

Page 11: Multistorey building

Wind force acting on the roof and wall

Live load coming on the building

Earth pressure in course of walls constructed below the ground level.

Let the total load coming on wall due to above mentioned force be P

If, A – Area of wall

P – Allowable Compressive strength of the brick

L – Length of wall

T – Thickness of wall

Then A – P/P

T x L – P/P

Or T – P/PL

For unit length, thickness – P/P

It has been found that loads acting on walls are eccentric

If e – eccentricity of the load

Max – pressure per unit area

Then – P/T [1 6e/T] and

Where Max. Compressive stress in Masonry

P/T [1 6e/T] and Minimum Stress – P/T [1 6e]

Partitions or Partition Walls: They are constructed as these walls enclosing areas

for rooms within a building either on ground floor or for upper floors. They vest either

on flooring concrete or on beams spanning between the main walls. They may be

taken either up to full floor height or up to 2.5m.

The following are the advantages of partition walls:

They divide the whole area into number of rooms.

They provide privacy to the in match from sight and sound.

They are light in weight and cheaper in cost of construction.

Being his in cross-section, they occupy less area of the floor.

11

Page 12: Multistorey building

2.4 DOORS WINDOWS AND LINTELS:

Doors: A door is frame work of wood or steel secured in and opening left in a wall

for the purpose of free movement of people and material in and out of a room. A door

is provided with Shutters. If two Shutters are provided, it is called double Shuttered

door and it one Shutter is provided, it is called single Shuttered door.

Parts of doors: A few Common types if doors are

Paneled doors

Ledged and battened doors

Ledges battened and braced doors.

A few special types of doors are

Flush doors

Revolving doors

Collapsible doors

Rolling Shutters

Sliding doors.

WINDOWS: A Window is a frame work of wood or steel secured in an opening in a

wall for the purpose of controlling light and ventilation in a room.

Types of windows:

Casement Window

Bay Window

Clerestory Window

Parts of windows:

A window consists

Frames

Shutters

12

Page 13: Multistorey building

LINTELS:

A lintel is a horizontal structural member which is fixed over the openings,

doors, windows recesses etc. to support the structure over opening. Lintels are usually

rectangular on shape and they afford facilities for fixing the door and window frames

wherever they are used.

Types of lintels: On the basis of material used in construction the lintel are classified

into the following types.

Wooden Lintels

Stone Lintels

Brick Lintels

Steel Lintels

Reinforced concrete lintels

Reinforced brick lintels (i.e. R.B. Lintels)

Depth of lintel: For ordinary loads 15cm depth for spans up to 1.2m and add another

2.5cm for every additional 40mm span.

2.5 ROOFS AND FLOORS:

Definition: A roof is the upper most part of a building whose function is to provide a

covering to keep out rain, snow, wind, etc.

Classification of roofs: Roofs are classified as follows. They are

(i) Pitched roofs. (ii) Flat roofs.

Pitched roofs: A pitched roof is a sloping roof. It is suitable for places where there is

heavy snow fall or rain fall.

Flat roofs: Common types of flat roofs are as follows

(i) Maura’s terrace roof. (ii) R.C.C roof.

R.C.C. roof: R.C.C Roofs are widely used in modern construction. For spans up to

2m for ordinary loads, a simple R.C.C slab is adequate. For greater spans a simple

R.C.C. beam and slab construction would be necessary. For constructing R.C.C.

floors or slabs the following procedure is adopted.

13

Page 14: Multistorey building

Erection of forms.

Typing and placing reinforcing grills.

Batching, mixing, placing and compacting.

Stripping of forms.

FLOORS:

Requirements of a good flooring: A good floor should floor should possess the

following features. They are as follows

It should have sufficient resistance to fire wear and tear, temperature changes and

chemical reactions.

It should have a sufficient resistance against dampness in buildings.

It should have a pleating appearance.

It should not cause noise.

It should have a smooth and even surface.

It should be cheap and economical to construct.

Ground and upper floors: Floors are the horizontal elements of a building structure

which divide the building in to different levels for the purpose of creating more

accommodations with in a restricted space one above the other and provided supports

for the occupants, furniture and equipment of a building.

A floor consists of the following two components.

A Sub-floor.

Floor coverings.

14

Page 15: Multistorey building

Floors suitable for different situations:

Sl.no. Type of flooring Requirements Types of flooring

suggested

1Laboratories,

hospitals, toilets

Should be non-absorbent,

capable of being cleaned

easily stain proof, to acid,

dust free, noise free

Polished stone

cuddapah slab

ceramic tiles mosaic

flooring

2Public buildings such

as schools, offices.

Should be resistant to wear

and tear i.e. hard dust free

non-slippery pleasing in

appearance.

Flag stone flooring

mosaic cuddapah

slabs cement

plastering.

Sub-floor: The purpose of this component is to impart strength and stability to

support floor covering and all other super imposed loads.

Floor covering: This is the covering over the sub-floor and is meant to provide a

hard, clean, smooth, impervious, durable and attractive surface to the floor.

Generally the following materials are used for grant floor construction. They

are as follows.

Bricks.

Stones.

Wooden blocks and

Concrete.

The upper floor in addition to having a good wearing surface should be stronger to

sustain heavier loads and should provide adequate sound insulation in buildings.

Floor and Roof: The top most covering constructed over an enclosed space of a

building is called roof. The intermediate slab provided to divide the vertical space in a

building to provide a storey is called a floor. They carry the super imposed loads due

to men and materials and transfer them to the super structure. An additional function

of the roof is to provide a cover the super structure to prevent rain, sun, wind, etc.,

from entering the building.

15

Page 16: Multistorey building

2.5.1 FLOORING:

Floor is the surface over which people perform different activities. It is laid so

that it is flush with the top of basement. It is laid over the earth or sand filling in the

space within basement walls.

2.6 STAIRS AND STAIRCASES:

Definition: Stairs are a series of steps arranged to connect different floors of a

building an enclosure which contains the stair way is called stair case.

Stair case can be constructed with timber, stones, bricks, steel etc… but R.C.C. has

almost replaced all other materials in our country and is widely used.

Location of staircase: The following points should be observed in locating stairs in a

building.

A stair case should be located so that it is easily accessible from the different

rooms of the building.

In the case of public buildings it should be located near the entrance.

Types of staircases: The common types of staircases are as follows.

Straight types of stairs.

Quarter turn stairs.

Half turn stairs.

o Dog legged stairs,

o Open well stairs.

Three quarter turn stairs.

Spiral stairs.

R.C.C. stairs: All types of stairs can be constructed with R.C.C. This stairs are

designed mainly in two ways they are as follows.

Stairs spanning horizontally.

Stairs spanning longitudinally.

16

Page 17: Multistorey building

Requirements and standards of staircases:

Minimum width:

Residential buildings =1.0m

Assembly buildings like auditoria =1.5m

Residential hotel buildings =1.5m

Theaters, cinema halls =1.5m

Educational buildings =1.5m

Intuitional buildings = 2.0m

Minimum treads: The maximum height of riser should be 190mm for residential

buildings and 150mm for other buildings. The number of steps in a flight should be

limited to 12.

To have easy climbing a descending the following relationships between going and

rise are adopted. They are as follows.

Going in mm 2 x rises in mm – 600.

Going in mm rise in mm – 4000 to 4100 (approximately)

Hand rails: The hand rails should have a minimum height of 0.9m from the centre of

the tread.

Landing: The width of landing should be the same as the width of stair.

2.7 PROTECTIVE AND DECORATIVE FINISHES:

Plastering:

Plastering is a thin coat of mortar applied on the surfaces of walls and ceilings,

plastering covers the uneven surface, scales and hides joints of walls and same times

used for decorative purposes. External plastering and other finishes applied for the

purpose of protection and decoration are rendering.

Objectives of plastering: The main objects of plastering are as follows.

To protect the exposed surfaces from atmospheric influence.

To cover decorative workmanship and interior quality materials.

To improve the appearance of the structure.

17

Page 18: Multistorey building

Types of plasters: Plastering can be applied with the following mortars.

Lime mortar.

Cement mortar.

Combination mortar or cement-lime mortar.

The plaster can be one or two coats of thickness 12mm or 20mm respectively.

Pointing: The finishing and protection of mortar joints of walls with cement mortar

or lime mortar is known as pointing. Generally pointing is done with cement mortar

(1:3) or (1:4).

Objectives of pointing: The main objects of point are:

To protect the joints from the disintegrating effects of wetness.

To serve as an alternative to plastering.

To cover weak mortar used.

To enhance the natural beauty of the construction materials.

White washing and colour washing: The internal and external walls are treated with

one, two or three coats of white wash made lime and water. If a pigment is added then

it is called colour wash.

The objects of white washings and colour washings are as follows:

To present a pleasing appearance.

To provide better distribution of light in the rooms.

To serve as a disinfectant.

Painting: Wooden and steel members and sometimes walls are painted for the

following reasons.

To protect the surface from weathering effects of the atmosphere.

To prevent decay of timber and rusting of steel.

To provide a pleasing appearance.

18

Page 19: Multistorey building

2.8 ASPECT (VASTU)

‘Aspect or Vastu’ is the basic need of all of us. Everyone wants a home built for

oneself equipped with all the amenities for a comfortable living. But many people

experience difficulties after having a house constructed against the principles of Vastu

due to ignorance. Thus, owning a house built in accordance to Vastu principles is

desirous for everyone and some general rules are presented below:

The southern and Western side compound wall should be thicker and higher than

the Northern and Eastern compound wall.

The building portion of Southern and Western side should be higher than Northern

and East sides. Building should be leaving more space in East and North than

West and South.

The gate should be in North-East in East for East facing house. The main door of

the house should be in North-East in East and if possible another door must be

placed in the Northern side for East facing home.

The well and underground water storage (sump) must be dug in the North-East in

East or in the North-East in North.

The generator, meter board and kitchen must be placed in South-East. Kitchen can

also be constructed in the North-West, West-South.

The overhead tank should be in the South-West.

The master bedroom is in the South-West. Balconies are built in the East & North

sides.

The high trees should be grown in the Southern-Western portion of the compound.

Bath-room, Latrine should be in the South-East, North-West, South or West.

The roof and floor slope must be from South-North or from West to East.

The stair-case in clock wise direction must be constructed in Southern and

Western sides.

The gate should be in the North-East in North for a North facing home.

The Septic tank must be dug in Ucchasthana of either in the North or East.

The water closet (w.c) should never be placed in North-East.

19

Page 20: Multistorey building

For South facing home gate should be in South-East in South. The main door of

the home in south facing must be placed in South-East in South. If possible the

second door must be placed in the North-East in North.

For West facing home gate should be in West. The main door of the home must be

placed in North-West in West. The second gate must be placed in the Eastern

Ucchasthana for West facing home.

20

Page 21: Multistorey building

CHAPTER-3

DESIGN OF SLABSSLABS:

Slabs are plate elements forming floors and roofs of buildings. Inclined

supported by beams or by walls and may be used as the flange of T/L beam. Further a

slab may be simply supported or continuous over one or more supports and is

classified according to the method support.

The provisions of IS: 456-2000.Clause no.23.2 for beams applied to slab also.

For slabs spanning in two directions, the shorter of the two spans should be used for

calculating the span to effective depth ratios. For two way slab of small span (up to

3.5m) with M.S. bars, the span to overall depth ratios given below may generally be

assumed to satisfy vertical deflection limits for loading class up to 3000 N/m2.

Simply supported slabs: 35

Continuous slabs: 40

For Fe415 steel the various given above should be multiplied by 0.8

a) One way slabs spanning in one direction

b) Two way slabs spanning in two directions.

c) Circular slabs.

d) Flat slabs resting directly in columns with no beams.

e) Grid floors and ribbed slabs.

Slabs are designed by using the same theories of bending and shear as used for beams.

The following methods are available for analysis.

A) Elastic analysis

B) Semi empirical co-efficient.

C) Yield line the theory

If the cross sectional area of the three basic structural elements, beam, slab and

column are related to the amount of the steel provided. It will be said that the percent

steel is usually maximum in a column than in a beam and a slab can beam made as

follows.

1) Slabs are analyzed and designed as having a unit width that is one meter wide

strips.

21

Page 22: Multistorey building

2) Compression reinforcement is used only in exceptional cases in a slab

3) Shear stresses are usually very low and reinforcement never provided in

slabs. It is preferred that to increase the depths. Of slabs and hence to decrease

the shear stresses.

4) Temperature reinforcement is invariably provided right angles to the main

longitudinal reinforcement in a slab.

5) Slabs are usually much thinner than beams.

TWO WAY SLABS:

When slabs are supported on four sides, two way spanning action occurs. Such

slabs be simply supported or continuous on any or all sides. The deflection and

bending moments in two-way slabs are considerably reduced as compared to those in

one-way slabs.

Thus a thinner slab can carry the same load when supported on four slabs,

where the length is greater than twice the breadth, two–way action effectively reduced

to one-way action the direction short span although the end beams to carry some slab

load.

22

Page 23: Multistorey building

SLAB TYPE 1:

Assume: fck = 20 N/mm2 fy = 415 N/mm2

Let Short span = Lx = 3.20 Longer span = Ly = 5.07

Ly/Lx = 5.07/3.20 = 1.584 <2

Two way slab

1. Thickness of slab:

Assume D=130mm

d=130-20=110

2. Loads on slab:

Dead load = 1 x 0.13 x 25 = 3.25 KN/m2

Live load = 2.0 KN/m2

Floor finish = 1.00 KN/m2

____________________

Total load = 6.25 KN/m2

Factored Load = 1.5 x 6.25 = 9.375 KN/m2

3. Design moments and shear forces:

Mux = αxwLx2

Muy = αywLy2

Where αx, αy are the bending coefficients for two way slabs for the one long edge and

one short edges are discontinued and negative.

For Ly/Lx = 5.28/3.31 = 1.595

(One long adjacent edge is discontinuous, case no. 3 in table no. 26 in IS 456:2000)

αx(-ve) = 0.067+(0.077-0.067) x 0.095/25 = 0.067

αx(+ve) = 0.051+(0.059-0.051) x 0.095/25 = 0.051

23

Page 24: Multistorey building

αy(-ve) = 0.037

αy(+ve) = 0.028

Mux(-ve)= αx(-ve)wLx2

= 0.067 x 9.375 x 3.312

= 6.88 KN-m

Mux(+ve)= αx(+ve)wLx2

= 0.051 x 9.375 x 3.312

= 5.23 KN-m

Muy(-ve)= αy(-ve)wLx2

= 0.037 x 9.375 x 3.312

= 3.8 KN-m

Muy(+ve)= αy(+ve)wLx2

= 0.028 x 9.375 x 3.312

= 2.87 KN-m

Vu = wu lx /2

= (9.375 x 3.31)/2

= 15.51 KN

4. Min depth required:

Depth required resisting the bending moment

Mu = 0.138 x fck x b x d2

6.88 x 106 = 0.138 x 20 x 1000 x d2

d = 49.92 <110

Hence provided depth is adequate

24

Page 25: Multistorey building

5. Reinforcement:

Along x-direction (short span)

Mux = 0.87 fy Ast d[1 - (Fy Ast/ Fck b d)]

6.88 x 106 = 0.87x 415x Ast x 110[1 - (415 x Ast/20x1000 x110)]173.23 = Ast (1-Ast/5301.204)

Ast2 – 5301.204Ast + 5301.204 x 173.23=0

Ast = 179.34 mm2

Using 8mm dia bars

6. Spacing of bars:

S = [ ast/ Ast]x 1000

= [(π/4) x 82/179.34] x 1000

= 280 mm

Max spacing:

(i) 3d = 3x110 = 330 mm

(ii). 300 mm

Whichever is less.

Hence provide 8 mm dia bars @ 280mm c/c spacing

Along y-direction (longer span)

These bars will be placed above the bars in x-direction

Hence d= 110-10 = 100mm

Muy = 0.87 fy Ast d2[1 -(Fy Ast/fckbd) ]

3.82 x106 = 0.87 x 415 x Ast x 100[1 - (415 x Ast/20x1000x100)]

105.24 = Ast[1 -( Ast/4819.277)

Ast = 107.41 mm2

25

Page 26: Multistorey building

Using 8 mm dia bars

Spacing of bars:

S = (ast/Ast)x 1000

= [(π/4)x82/107.41] x 1000

S = 467.97 mm

Max spacing:

i. 3d = 3x100 = 168 mm

ii. 300mm

Whichever is less

Hence provide 8mm dia. bars at 300 mm c/c spacing

7. Reinforcement in Edge Strip:

Ast = 0.12% of gross area

= (0.12/100 x 1000 x 130) = 156mm2

Using 8mm bars, Spacing

S =[(π/4)x82/156] x 1000 =322

Maximum spacing is

i. 5d = 5 x 110= 550

ii. 450mm whichever is less

Hence, provide 8mm bars at 320mm c/c in edge strips in both directions

8. Check for deflection:

For simply supported slab basic value of l/d ratio = 20

Modification factor for tension steel F1

% of steel = 0.12

fs = 0.58 fy

= 0.58 x 415 = 240.7 N/mm2

MF = 1.6

Max permitted l/d ratio = 1.6 x 20 = 32

l/d provided = 3310/110 = 30.09<32

Hence deflection control is safe.

26

Page 27: Multistorey building

SLAB TYPE 2:

Let fck = 20 N/mm2 fy = 415 N/mm2

Short span = Lx = 4.64 Longer span = Ly = 5.07

Ly/Lx = 5.07/4.64 = 1.09 <2

Two way slab

1. Thickness of slab:

Assume D=130mm

d=130-20=110

2. Loads on slab:

Dead load = 1 x 0.13 x 25 = 3.25 KN/m2

Live load = 2.0 KN/m2

Floor finish = 1.00 KN/m2

____________________

Total load = 6.25 KN/m2

Factored Load = 1.5 x 6.25 = 9.375 KN/m2

3. Design moments and shear forces:

Mux = αxwLx2

Muy = αywLy2

Where αx, αy are the bending coefficients for two way slabs for the one side

discontinuous and three sides continuous.

For Ly/Lx = 5.18/4.75 = 1.09

(One long edge is discontinuous as per table no. 26 in IS 456:2000)

αx(-ve) = 0.037+(0.044-0.037) x 0.09/10 = 0.037

αx(+ve) = 0.028+(0.033-0.028) x 0.09/10 = 0.028

αy(-ve) = 0.037

αy(+ve) = 0.028

27

Page 28: Multistorey building

Mux(-ve) = αxwLx2

= 0.037 x 9.375 x 4.642

= 7.826 KN-m

Mux(+ve) = αxwLx2

= 0.028 x 9.375 x 3.312

= 5.922 KN-m

Muy(-ve) = αywLx2

= 7.826 KN-m

Muy(+ve) = αywLx2

= 5.922 KN-m

Vu = wulx /2

= (9.375 x 4.75)/2

= 22.265 KN

4. Min depth required:

Mu = 0.138 x fck x b x d2

7.826 x 106 = 0.138 x 20 x 1000 x d2

D = 48.38 <110

Hence provided depth is adequate

5. Reinforcement:

Along x-direction (short span)

Mux = 0.87 fy Ast d[1 - (Fy Ast/ Fck b d)]

7.826 x 106 = 0.87x 415x Ast x 110[1 - (415 x Ast/20x1000 x110)] 197.05 = Ast (1-Ast/5301.204)

Ast2 – 5301.204Ast + 5301.204 x 197.05=0

Ast = 204.97 mm2

Using 10mm dia bars

28

Page 29: Multistorey building

Spacing of bars:

S = [ ast/ Ast]x 1000

= [(π/4)x102/204.97] x 1000

= 383.177 mm

Max spacing:

(i) 3d = 3x110 = 330 mm

(ii) 300 mm

Whichever is less.

Hence provide 10mm dia bars @ 300mm c/c spacing

Along y-direction (longer span)

These bars will be placed above the bars in x-direction

Hence d= 110-10 = 100mm

Muy = 0.87 fy Ast d2[1 -(Fy Ast/fckbd) ]

7.826 x 106 = 0.87 x 415 x Ast x 100[1 - (415 x Ast/20x1000x100)]

216.75 = Ast[1 -( Ast/4819.277)]Ast = 226.42 mm2

Using 8 mm dia bars

Spacing of bars:

S = (ast/Ast)x 1000

=[(π/4)x82/226.42] x 1000

S = 346.57 mm

Max spacing:

ii. 3d = 3x100 = 168 mm

ii. 300mm

Whichever is less

Hence provide 8mm dia bars at 300 mm c/c spacing

29

Page 30: Multistorey building

6. Reinforcement in Edge Strip:

Ast = 0.12% of gross area

= (0.12/100 x 1000 x 130) = 156mm2

Using 8mm bars, Spacing

S =[(π/4)x82/156] x 1000 =322

Maximum spacing is

i. 5d = 5 x 110= 550

ii. 450mm whichever is less

Hence, provide 8mm bars at 320mm c/c in edge strips in both directions

7. Check for deflection:

For simply supported slab basic value of l/d ratio = 20

Modification factor for tension steel F1

% of steel = 0.12

fs = 0.58 fy

= 0.58 x 415 = 240.7 N/mm2

MF = 1.6

Max permitted l/d ratio = 1.6 x 20 = 32

l/d provided = 3310/110 = 30.09<32

Hence deflection control is safe.

30

Page 31: Multistorey building

CHAPTER-4

DESIGN OF BEAMSBEAMS:

A reinforcement concrete beam should be able to resist tensile, Compressive

and shear stresses as induced in it by the loads on the beam. Concrete is fairly strong

in compression but very weak in tension. The plain concrete is overcome by the

provision of reinforcement in tension, thus the tensile weakness of concrete is

overcome by the provision of reinforcement in tension zone to make reinforced

concrete beam.

M ulim of the given section is calculated and is compared with the maximum

bending moment of the section. If Mulim is greater than Mu The section is designed as

singly reinforced section. If Mlim is less than Mu the section is designed as a doubly

reinforced section. Mu/bd2 is calculated and percentage of steel is required in tension

and compressions corresponding to grade of steel are obtained from S 16-1980.

Reinforcement required for bending and shear in beams in calculated in accordance

with the provision laid down in clauses 26.5.40.1 and 40.3 of IS456:2000

There are three types of reinforced concrete beams.

a) Singly reinforced beams.

b) Doubly reinforced beams

c) Flanged beams

SINGLY REINFORCED BEAMS:

In singly reinforced simply supported beams reinforcing steel bars are placed

near the bottom of the beak where they are most effective in resisting the tensile

bending stresses. In singly reinforced cantilever beams steel is placed near the top of

the beam for the same reason.

DOUBLY REINFORCED BEAMS:

A doubly reinforced beam is reinforced in both compression and tension

regions. The section of the beam may be rectangle or T/L in shape. The necessity of

using steel in the compression regions arises due to two reasons.

1) When depth of beam is restricted, the strength available from a singly

reinforced beam is inadequate.

2) As the supports of the continuous beams where the bending moment changes

sign. Such a situation may also arise in the design of a ring beam.

31

Page 32: Multistorey building

FLANGED BEAMS:

In most of R.C. Structures, concrete slabs and beams are cast monolithic. Thus

beams form a part of the floor system together with the slab. In bending slab forming

the part of the beam at mid span would be in compression for a width of the rib, thus

increasing the moment of resistance for a given rib width. At continuous supports, the

position is reversed. The slab is in tension and part of the rib is in compression. Since

concrete is assumed to have cracked in tension, this beam is equivalent to a

rectangular section at the supports.

DESIGN OF BEAM 1:

Let fck = 20 N/mm2 fy = 415 N/mm2

Span of the Beam L= 5.07m

1. Depth of the Beam:

Selecting the depth in range of l/12 to l/15 Based on stiffness

d = 5070/12 =422

Adopt d = 450mm

D = 500mm

Let take B = 300mm

2. Loads per meter length of Beam:

Dead Load = .3x.5x25 = 3.75 KN/m

a. Load from Slab wlx6

¿

=5.875 x (3.20)/6 [3-(3.20/5.07)2)= 8.151 KN/m

b. Load from Slab

=5.875 x (4.64)/6 [3-(4.64/5.07)2)= 9.824 KN/m

Load from wall =0.23 x2.7 x19 = 11.8 KN/m

____________

Total Load = 33.525 KN/m

____________

Factored Load 1.5 x 33.525 = 50.28 KN/m

Shear Force wul/2=(50.28 x 5.07/2) = 127.46 KN

32

Page 33: Multistorey building

Bending Moment

w l2

8 =(50.28×5.072/8) = 161.55 KN-m

3. Min. Depth Required:

Mu = Mu lim.

= 0.138 x fck x b x d2

161.55 x 106 = 0.138 x 20 x 300 x d2

d = 441.71 mm<450mm

Hence, provided depth is adequate

Mu lim. = 0.138x20x300x4502

= 167.67 x106

Mu < Mu lim

Hence it is a singly reinforced beam

4. Reinforcement:

Mu = 0.87 x fy x Ast x d[1-(fy xAst/fckbd)]

167.67 x 106 = 0.87 x 415 x Ast x 450[1-(415/20 x 300 x 450]

994 = Ast[1-( Ast /6506.02)]Ast

2 - 6506.02 + (6506.02 x 994) =0

Ast= 1224.8mm2

Providing 16mm dia bars

[1146.98/ (π/4 x 162) = 5.70 = 6 no.of bars

By providing 16mm dia 4 bars

4 x π/4 x 162 = 804.24 mm2

By providing 12mm dia 4 bars

4 x π/4 x 122 = 452.39 mm2

Hence, Ast Provided = 1256.63mm2

5. Check for shear:

% of steel = 100 x Ast/bd

= 100 x 1256.63/300x500

= 0.9%

As per IS456:2000 code book

33

Page 34: Multistorey building

τc = 0.6 N/mm2

and τv = Vu/(b x d)

= 127460/(300 x 450)

= 0.94 N/mm2

Since τv > τc , shear reinforcement has to be designed

Vus = Vu - τ cbd

= 127460 – 0.6 x 300 x 450

= 46460N

6. Shear Resistance of Bent up Bars:

Shear Resistance of Bent up bars

Vusb =0.87fyAsbsinα

=0.87 x 415 x 2 x(π/4 x 162) x sin450

=102662N

7. Design of vertical Stirrups:

Shear resistance to be provided by the vertical stirrups= Vus/2= 46460/2= 23230N

Spacing of 2 legged 6mm stirrups

Asv =2 x (π/4 x62) =56.5mm2

Spacing from minimum shear reinforcement consideration as per IS 456

(Asv/b x Sv) = 0.4/0.87 x fy

Sv = (0.87 x fy x Asv /0.4 x b)

Sv =(0.87 x 415 x 56.5/0.4 x300)

= 170mm

Maximum allowed spacing

=0.75d = 0.75 x450=337.5

Or 300mm whichever is less.

Hence Provide 2-legged 6mm stirrups @ 170mm c/c throughout the span of the

beam

8. Check for deflection:

% of steel = 100 x Ast/bd

= 100 x 1256.63/300x450

= 0.93

34

Page 35: Multistorey building

Modification factor Kt = 1, Kc = 1 and Kf =1

(L/d)max = (L/d)basic x Kt x Kc x Kf = 20x1x1x1=20

(L/d)actual = 5070/450 = 11.2 < (L/d)max, Hence safe.

Fig4.1: Cross Section detailing of a beam

35

Page 36: Multistorey building

BEAM TYPE 2

Let fck = 20 N/mm2 fy = 415 N/mm2

Span of the Beam L= 5.07m

1. Depth of the Beam:

Selecting the depth in range of l/12 to l/15 Based on stiffness

d = 4640/12 =386

Adopt d = 400mm

D = 450mm

Let take B = 300mm

2. Loads per meter length of Beam:

Dead Load = .3x.45x25 = 3.375 KN/m

Load from Slab

2 x wlx3

= 2x (5.875 x 4.64/3) = 18.173 KN/m

Load from wall =0.23 x2.7 x19 = 11.8 KN/m

____________

Total Load = 33.348 KN/m

____________

Factored Load 1.5 x 33.348 = 50.02 KN/m

Shear Force wul/2=(50.02 x 4.64/2) = 116 KN

Bending Moment

w l2

8 =(50.02×4.642/8) = 134.61 KN-m

3. Min. Depth Required:

Mu = Mu lim.

= 0.138 x fck x b x d2

134.61 x 106 = 0.138 x 20 x 300 x d2

d = 403mm>400mm

Hence, provided depth is not adequate

Let take 420mm effective depth then

36

Page 37: Multistorey building

Mu lim. = 0.138x20x300x4002

= 146.05 x106

Mu < Mu lim

Hence it is a singly reinforced beam

4. Reinforcement:

Mu = 0.87 x fy x Ast x d[1-(fy xAst/fckbd)]

134.61 x 106 = 0.87 x 415 x Ast x 420[1-(415/20 x 300 x 420]

887.688 = Ast[1-( Ast /6072.28)]Ast

2 – 6072.28 + (6072.28 x 887.688) =0

Ast Required= 1079.64mm2

Providing 16mm dia bars

[1079.64/(π/4 x 162) = 5.37 = 6 no.of bars

By providing 16mm dia 6 bars

6 x π/4 x 162 = 1206.371 mm2

Hence, Ast Provided = 1206.371mm2

5. Check for shear:

% of steel = 100 x Ast/bd

= 100 x 1206.371/300x450

= 0.89%

As per IS456:2000 code book

τc = 0.6 N/mm2

and τv = Vu/(b x d)

= 116020/(300 x 420)

= 0.92 N/mm2

Since τv > τc , shear reinforcement has to be designed

Vus = Vu - τ cbd

= 116020 – 0.6 x 300 x 420

= 40420N

37

Page 38: Multistorey building

6. Shear Resistance of Bent up Bars:

Shear Resistance of Bent up bars

Vusb =0.87fyAsbsinα

=0.87 x 415 x 2 x(π/4 x 162) x sin450

=102662N

7. Design of vertical Stirrups:

Shear resistance to be provided by the vertical stirrups= Vus/2= 40420/2= 20210N

Spacing of 2 legged 6mm stirrups

Asv =2 x (π/4 x62) =56.5mm2

Spacing from minimum shear reinforcement consideration as per IS 456

(Asv/b x Sv) = 0.4/0.87 x fy

Sv = (0.87 x fy x Asv /0.4 x b)

Sv =(0.87 x 415 x 56.5/0.4 x300)

= 170mm

Maximum allowed spacing

=0.75d = 0.75 x450=337.5

Or 300mm whichever is less.

Hence Provide 2-legged 6mm stirrups @ 170mm c/c throughout the span of the

beam

8. Check for deflection:

% of steel = 100 x Ast/bd

= 100 x 1206.371/300x420

= 0.95

Modification factor Kt = 1, Kc = 1 and Kf =1

(L/d)max = (L/d)basic x Kt x Kc x Kf = 20x1x1x1=20

(L/d)actual = 4640/420 = 11.04 < (L/d)max, Hence safe.

38

Page 39: Multistorey building

CHAPTER-5

DESIGN OF COLUMNSCOLUMNS:

The load on columns is calculated by trapezium method. This method is used

when the loads on the beams coming from the slabs and walls are known prior ot

column design. The load on column at each floor level is given by,

Pu = Half of the loads coming from the beams which are rest on that column

on each floor + Pself(factored)

Pself = Self weight of the column at the floor level under consideration

DESIGN OF COLUMNS:

Assume: fck = 20 N/mm2 fy = 415 N/mm2

Load from Beam B3 = Total load

2=50.28 x 5.07/2 = 127.46KN

Load from Beam B4 =Total load

2 =50.28 x 5.07/2 = 127.46KN

Load from Beam B24 =Total load

2 = 50.02 x 4.64/ 2 = 116.04KN

Load from Beam B25=Total load

2 =41.55 x 3.20/2 = 66.48 KN ___________ Total Factored load = 437.44KN

Load transferred to the column from 5 floors is estimated to be = 2624.64 KN

Height of column = 3m

Assume 1% of steel,

Asc = 1% of Ag = 0.01 Ag, Ag = Ac + Asc

Ac = Ag - Asc = Ag – 0.01 Ag = 0.99 Ag

For axially loaded short column

pu = 0.4 fck Ac + 0.67 fy Asc

2624.64 x 103 = 0.4 x 20 x 0.99 Ag + 0.67 x 415 x 0.01 Ag

39

Page 40: Multistorey building

2624.64 x 103 = 7.92 Ag + 2.78 Ag

Ag = 245293.45mm2

Since the column is rectangular and take one side of the column is 450mm, dimension

of other side is = 245293.45/450

Adopt = 450 x 550= 247500 mm2 rectangle column

Asc = 0.01 x Ag, = 0.01 x 247500 = 2475 mm2

Ac = Ag – Asc = 247500 – 2475 = 245025 mm2

Provide 20mm dia, no. of bars

= 2475/(π/4 x 202) = 7.87=8 no. of bars

Asc provided= (8 x π/4 x 202) = 2513.27mm2

Lateral ties diameter of lateral ties should not be less than

Φ/4 = ¼ x 20 = 5mm

Hence adopt 6mm diameters bars

Pitch of the ties shall be minimum of

Least lateral dimensions of column = 450 mm

16 times the dia of longitudinal bar = 16 x 20 = 320 mm

300 mm

Hence provide 6 mm lateral ties at 300 mm c/c.

40

Page 41: Multistorey building

CHAPTER-5

DESIGN OF FOOTINGS

FOOTINGS

Footing or Foundation is defined as the part of substructure, which transmits the load

from superstructure to surrounding soil stratum safely.

Foundations are classified in to two types.

1. Shallow foundation 2. Deep foundation

DESIGN OF FOOTING:

Axial Load = 2624.64KN

Size of the columns = 450×550mm

SBC of soil = 350 KN/m2

fck = 20 N/mm2

fy = 415 N/mm2

1. Size of the Footing:

Load from the column P = 1750KN

Self weight of footing = 10% of column load load = 1750/100= 175KN

Total load on soil = 1925KN

Area of the footing = (Toal load/SBC of soil) = 1925/350 = 5.5m2

Provide 2.2m×2.5m footing

2. Upward Soil Pressure:

Factored Load Pu = 1.5×1750 = 2624.26 KN

Soil Pressure at ultimate load

qu = (Pu/area of footing)

qu = (2426.64/2.2×2.5) = 441 KN/m2 = 0.441 N/mm2

3. Depth of Footing from Bending Moment Consideration:

41

Page 42: Multistorey building

Bending moment along longet direction

MuL = quB ¿¿

=0.441 × 2200¿¿= 461.14×106 N-mm

Bending moment along shorter direction

MuB = quL ¿¿

= 0.441 × 2500¿¿= 422.05×106 N-mm

For sloped footing, equivalent breadth,

be = b+(B-b)/8

= 450 + (2200-450)/8 = 668.75mm

MuL = 0.138fckbd2

461.14×106 = 0.138×20×668.75×d2

d = 499.83mm

Provide 750mm effective depth and 800mm overall depth. Increased depth taken due

to shear consideration.

4. Reinforcement:

Mu = 0.87 x fy x Ast x d[1-(fy xAst/fckbed)]

461.14 x 106 = 0.87 x 415 x Ast x 750[1-(415/20 x 668.75 x 750]

1702.9 = Ast[1-( Ast /24171.7)]Ast

2 – 24171.7 + (24171.7 x 1702.9) =0

Ast Required= 1843.5mm2

Using 16mm dia bars, spacing of bars

S = ast × (B/Ast) = (π/4×162)×(2200/1843.5)

= 239.9mm

Hence, provide 16mm bars at 220mm c/c in longer direction

5. Reinforcement along shorter direction:

MuB = 0.87 x fy x Ast x d[1-(fy xAst/fckbd)] d = 550-16 = 534mm

42

Page 43: Multistorey building

422.05 x 106 = 0.87 x 415 x Ast x 534[1-(415/20 x 2500 x 534]

2189.04 = Ast[1-( Ast /64337.34)]Ast

2 – 64337.34 + (64337.34 x 2189.05) =0

Ast Required= 2269.06mm2

The above reinforcement is to be provided in a width of 2500mm. Area of steel to be

provided in the column width of 2200mm is,

Ast1 = (2×Ast/β+1) = 2

( 25002200

+1)×2269.06 = 2124.22mm2

Using 16mm dia bars, spacing of bars

S = ast × (B/Ast) = (π/4×162)×(2200/2124.22) = 208.23mm

Hence, provide 16mm bars at 200mm c/c in the central band of width 2000mm along

shorter direction. The remaining reinforcement (2269.06-2124.22= 144.84mm2) has

to be provided in the outer band.

Using 12mm dia bars, spacing of bars

S = ast × (B/Ast) = (π/4×122)×(500/144) = 392.7mm

Hence, provide 12mm bars at 250mm c/c in the outer band of width 500 mm along

shorter direction.

6. Check for One Way Shear:

Factored shear force

Vu = Soil pressure from the shaded area

= 0.441×2200[(2500−550 )

2−750]

= 218295N

At the critical section:

Width of footing at top = a+2d = 550+(2×750) = 2050mm

43

Page 44: Multistorey building

Average width A1 = (2050+2500)/2 = 2275mm

Depth of footing d1 = 275+(750-275)×(1000-750)/100

= 393.75

τv = Vu/A1d1 = 218295/2275×393.75= 0.215 N/mm2

it is less than minimum strength of M20 concrete = 0.28N/mm2 (Table -19 of IS:

456)

7. Check for Two Way Shear:

The critical section is at a distance of d2 from the face of the column.

Perimeter of the critical section = 4(b+d) = 4(450+750) = 4800 mm

Depth of footing at critical section d2 = 225+(750-225)×(1000-375)/1000

= 553.125mm

Two way shear Vu2 = qu x area of shaded portion

= 0.441((2200 x 2500)-(1300 x 1200))

= 1737.54 x 103N

Two way shear stress = Vu2A =

1737.54 ×10004800 ×553.125 = 0.654 N/mm2

Permissible punching stress τp = 0.25 √ fck

= 0.25 × √20 = 1.12N/mm2 > 0.654N/mm2

Hence, it is safe with respect to two way shear.

44

Page 45: Multistorey building

Fig5.1: Section of the Footing

Fig5.2: Plan of the Footing

45

Page 46: Multistorey building

CHAPTER-6

DESIGN OF STAIRCASESTAIR CASE:

The purpose of the staircase is to provide pedestrian access to different

levels within the building. The geometrical forms of staircase may be quite different

depending on the individual circumstances involved. The two main components of

staircase are stairs and landing slab. The stairs and landing slab can be arranged in

different forms together in different types of staircases.

1) Type of construction of the structure around the staircase i.e., load bearing brick

structure or reinforced concrete frame structure.

2) Availability of space.

Rise and tread are two terms associated with a stair. The term rise refers to

vertical height of a step and the term tread represents the horizontal dimension where

out foot placed.

GENERAL RULES: Between consecutive floors there should be an equal rise for every parallel

step. Similarly there should be equal tread.

The sum of tread of single step, twice the rice should be in between 550mm an

700mm.

The rice of the step should not be more than 200mm and tread should not be

less than 240mm

DESIGN PROCESS:

1. Proportioning of stair case:

Dimensions of stair hall = 3.1 × 3.2m

Height of the each floor = 3m

Height of each flight = 3/2 = 1.5m

Rise R = 150mm

Tread T = 240mm

Number of Rises = 1500/150 = 10 nos

Hence, No. of treads = 10-1 = 9

Adopt width of stair case = 1.5m

46

Page 47: Multistorey building

For 9 treads, Length required = 9 × 0.24 = 2.16m

Provide width of landing = 3200-2160 = 1040mm

2. Thickness of slab:

Assume effective depth

d = span/25 = 3200/25 = 128mm

Hence provide d= 130mm and D = 160mm

3. Loads: Loads per meter horizontal width of stairs are as follows:

Weight of waist slab = D√1+¿¿

= 0.16√1+¿¿

= 4.716 KN/m2

Weight of steps = 1/2× RT

T ×25 = R×25/2

= 0.15×(25/2) =1.875 KN/m2

Live Load = 3 KN/m2

Floor finish = 0.6 KN/m2

Total load = 10.191 KN/m2

Factored Load = 10.191 ×1.5 = 15.286 KN/m2

4. Factored Bending Moment:

Mu = wul2/8

= 15.286 × 3.22/8

= 19.56 KN-m

5. Minimum depth required:

Mu = 0.138 fck bd2

19.56 × 106 = 0.138×20×1000×d2

d = 84.18< 130mm

Hence, provided depth is adequate.

6. Tension Reinforcement:

Mu = 0.87 fy Ast d[1-(415 Ast/fck bd)]

19.56×106 = 0.87 x 415 x Ast x 130[1-(415/20 x 1000 x 130]

416.73 = Ast[1-( Ast /6265.06)]Ast

2 – 6265.06 + (6265.06 x 416.73) =0

47

Page 48: Multistorey building

Ast Required= 448.89mm2

Using 12mm diameter bars, spacing of bars

S = (ast/Ast ×1000)

= (π/4×122/448.89)×1000

= 251.94mm

Hence, provide 12mm dia bars at 250mm c/c spacing

7. Distribution Reinforcement:

Ast = 0.12% of gross area

= 0.12 ×1000×160/100 = 192mm2

Using 8mm dia bars, spacing

S = (π/4×82×1000)/192

= 261.8mm

Hence, provide 8mm dia bars at 250mm c/c spacing.

48

Page 49: Multistorey building

CHAPTER 7

COST ESTIMATION7.1 RATE ANALYSIS:

Cost estimation or Rate Analysis is a well-formulated prediction of the probable

construction cost of a specific building project. A cost estimate can be an important

management tool to library planners during the design phases of a project providing

information about the facility and the project budget. All projects begin with an idea

and end by filling a need. Most projects at conceptual design require changes to

present an acceptable workable solution. The conceptual cost estimate is becoming

more important to owners, architects, and builders. It is a tool for determining

required funding and to gauge the needs of a project. This tool continues to be refined

during the design stages of the project.

The cost estimate accounts for all items that will generally be included in the

general contractor’s bid. The cost estimate is prepared by breaking down the items of

work using a standard format and determining the cost of each item from experience

and a database of current construction cost information.

A cost estimate should not be confused with a project budget. A project budget

will include the total of the cost estimate, and will also include what are known as

“soft costs”. These soft costs will specifically be excluded from the cost estimate and

will typically include land acquisition, architectural and design fees, movable

furniture and equipment, building permits and fees, fire and all risk insurance. The

project budget will also include non-construction related costs such as fund raising

and moving costs.

7.2 TYPES OF COST ESTIMATE

Cost estimates fall into two groups: conceptual estimates and detailed

estimates. Each can be broadly defined as follows:

Conceptual Estimate

Conceptual estimating or parametric estimating is the process of establishing a

project’s cost, often before any graphical representation of a facility has been

developed.

Detailed Estimate

The detailed construction estimate is the product of a process whereby the cost of a

proposed Construction project is predicted. The estimate is prepared by breaking

49

Page 50: Multistorey building

down the items of work in an orderly and logical basis, determining the cost of each

item from experience, and summarizing the total.

The Estimation should be accompanied with:

Report

Specification

Drawings (plans, elevation, sections)

Design charts and calculations

Standard schedule of rates

Factors to be considered while preparing Detailed Estimate:

i. Quantity and transportation of materials: for bigger project, the requirement of

materials is more. Such bulk volume of materials will be purchased and

transported definitely at cheaper rate.

ii. Location of site: The site of work is selected, such that it should reduce

damage or in transit during loading, unloading, stocking of materials.

iii. Local laboure charges: The skill, suitability and wages of local labours are

considered while preparing the detailed estimate

Fixing of Rate per Unit of an Item:

The rate per unit of an item includes the following:

i. Quantity of materials & cost: The requirement of materials is taken strictly in

accordance with standard data book (S.D.B). The cost of these includes first

cost, freight, insurance and transportation charges.

ii. Cost of labour: The exact number of labourers required for unit of work and

the multiplied by the wages/ day to get of labour for unit item work.

iii. Cost of equipment (T&P): Some works need special type of equipment, tools

and plant. In such case, an amount of 1 to 2% of estimated cost is provided.

iv. Overhead charges: To meet expenses of office rent, depreciation of equipment

salaries of staff postage, lighting an amount of 4% of estimate cost is

allocated.