MyChron Expansion USER GUIDE AiM TECH Srl. Via Cavalcanti, 8 20063 Cernusco S/N (MI) Italia Tel. (+39) 02.9290571 www.aim-sportline.com Made in Italy
Transcript
Page 1: MyChron Expansion€¦ · MyChron Expansion analog inputs MyChron Expansion has 4 inputs, that can be connected to these sensors: nChannel 1 and 2 can also be connected to a digital

MyChron ExpansionUSER GUIDE

AiM TECH Srl.Via Cavalcanti, 8 20063 Cernusco S/N (MI)ItaliaTel. (+39) 02.9290571

www.aim-sportline.comMade in Italy

MANUALE MY EXPANSION 2017.qxp_Layout 1 17/03/17 08:53 Pagina 1

Page 2: MyChron Expansion€¦ · MyChron Expansion analog inputs MyChron Expansion has 4 inputs, that can be connected to these sensors: nChannel 1 and 2 can also be connected to a digital

MyChron5 and MyChronExpansion

This user manual explains how to use AiMMyChron Expansion with your MyChron5.

Firmware release from 1.24.14 or higher.

INTRODUCTION MYCHRON EXPANSION

MANUALE MY EXPANSION 2017.qxp_Layout 1 17/03/17 08:53 Pagina 3

Page 3: MyChron Expansion€¦ · MyChron Expansion analog inputs MyChron Expansion has 4 inputs, that can be connected to these sensors: nChannel 1 and 2 can also be connected to a digital

MyChron Expansion analog inputs

MyChron Expansion has 4 inputs, that can be connected tothese sensors:

n Channel 1 and 2 can also be connected to a digital speed sensor.

Each enabled channel is recorded at 20 Hz.

After having connected a MyChron Expansion you need toconfigure MyChron5 in order to manage the sensors.

The steps to follow are:

n choose the sensor connected to each channel

n if necessary, configure the sensor, setting the proper parameters

n if necessary, calibrate the sensors

n configure the display custom page(s) where the informationcoming from the sensors will be shown.

ANALOG INPUTS MYCHRON EXPANSION

n Throttle potentiometern Brake potentiometern Water temperature thermo resistance

n Speed sensorsn Steering angle potentiometersn Generic 0-100% sensorsn Brake pressure sensorsn Gas valve (AiM power valve)n Wheel temperature sensorsn Generic 0-5V sensors

MANUALE MY EXPANSION 2017.qxp_Layout 1 17/03/17 08:53 Pagina 5

Page 4: MyChron Expansion€¦ · MyChron Expansion analog inputs MyChron Expansion has 4 inputs, that can be connected to these sensors: nChannel 1 and 2 can also be connected to a digital

MyChron configuration

• Connect AiM MyChron Expansion to your MyChron5• Press "MENU" –> "Config Params"

• Press "ENTER"

• in "Config Params" page press "Expansion Setup" icon.

CONFIGURATION MYCHRON EXPANSION

Pressing "ENTER" you reach this page.

MANUALE MY EXPANSION 2017.qxp_Layout 1 17/03/17 08:53 Pagina 7

Page 5: MyChron Expansion€¦ · MyChron Expansion analog inputs MyChron Expansion has 4 inputs, that can be connected to these sensors: nChannel 1 and 2 can also be connected to a digital

Press "ENTER" to set each channel function (i.e. speed)

Then you need to select the sensor type and other parame-ters possibly required.

When all channels have been set you are prompted to"Channels Setup" page, that now shows all the sensors youset.

CONFIGURATION MYCHRON EXPANSION

MANUALE MY EXPANSION 2017.qxp_Layout 1 17/03/17 08:53 Pagina 9

Page 6: MyChron Expansion€¦ · MyChron Expansion analog inputs MyChron Expansion has 4 inputs, that can be connected to these sensors: nChannel 1 and 2 can also be connected to a digital

Selecting a sensor that needs to be calibrated "CALIB" pushbutton appears.

Push it, follow the instructions prompted on MyChron5 display and press "SAVE".

Press “Exit” twice to return to the new page with "Config Params" icon selected.

Display Setup

Once MyChron Expansion channels are set you can alsoshow them on MyChron5 custom pages.In "Config Params" page scroll until "Display setup" icon andpress “Enter.”

DISPLAY SETUP MYCHRON EXPANSION

MANUALE MY EXPANSION 2017.qxp_Layout 1 17/03/17 08:53 Pagina 11

Page 7: MyChron Expansion€¦ · MyChron Expansion analog inputs MyChron Expansion has 4 inputs, that can be connected to these sensors: nChannel 1 and 2 can also be connected to a digital

n Select the Custom page where to show MyChron Expansionchannels (i.e. Custom 1).

n Enable the pagen Press "CONFIG"

Display Setup

Entering the Custom page you see RPM Bar graph on topand four fields set as None:

DISPLAY SETUP MYCHRON EXPANSION

MANUALE MY EXPANSION 2017.qxp_Layout 1 17/03/17 08:53 Pagina 13

Page 8: MyChron Expansion€¦ · MyChron Expansion analog inputs MyChron Expansion has 4 inputs, that can be connected to these sensors: nChannel 1 and 2 can also be connected to a digital

n Three fields can be set only as measure fieldn Place the function you want to show in the field you prefer

n The fourth field – bottom right – can be set either as laptime or as measure field. Lap time options are shown top ofthe list – see below

nOnce all fields set press "EXIT"

Network Information

To know the firmware version of your MyChron Expansiongo to "Config Params" page and press "System Info":

NETWORK INFORMATION MYCHRON EXPANSION

MANUALE MY EXPANSION 2017.qxp_Layout 1 17/03/17 08:53 Pagina 15

Page 9: MyChron Expansion€¦ · MyChron Expansion analog inputs MyChron Expansion has 4 inputs, that can be connected to these sensors: nChannel 1 and 2 can also be connected to a digital

In "System Info" page:

n Select "NetInfo" option as here belown Press "ENTER"

Network Information

Network information page shows all expansions connectedto your gauge as well as their serial number and firmwareversion.

NETWORK INFORMATION MYCHRON EXPANSION

MANUALE MY EXPANSION 2017.qxp_Layout 1 17/03/17 08:53 Pagina 17

Page 10: MyChron Expansion€¦ · MyChron Expansion analog inputs MyChron Expansion has 4 inputs, that can be connected to these sensors: nChannel 1 and 2 can also be connected to a digital

Technical specifications

Sampling frequencyDimensionsWeightWaterproof

10Hz127x24x33 mm194gIP65

TECHNICAL SPECIFICATIONS MYCHRON EXPANSION

MANUALE MY EXPANSION 2017.qxp_Layout 1 17/03/17 08:53 Pagina 19


Recommended