+ All Categories
Home > Documents > MZA 6010 - Super Systems · MZA 6010 SuperSystem A18-05132015-001 The MZA 6010 is a Multi-Gas...

MZA 6010 - Super Systems · MZA 6010 SuperSystem A18-05132015-001 The MZA 6010 is a Multi-Gas...

Date post: 22-Jan-2021
Category:
Upload: others
View: 3 times
Download: 0 times
Share this document with a friend
2
INNOVATIVE SOLUTIONS WORLDWIDE s incorporated MZA 6010 Super System A18-05132015-001 The MZA 6010 is a Multi-Gas Infrared (IR) analyzer used to analyze gases in multiple zones of a furnace or furnaces. It measures Carbon Monoxide (CO), Carbon Dioxide (CO 2 ) and Natural Gas (CH 4 ) typically found in an endothermic atmosphere. The measurement of these gases, combined with furnace temperature information, allows the MZA 6010 to calculate the percent Carbon (%C) of the measured gas. A Hydrogen (H 2 ) sensor can also be incorporated as an option to provide a more complete picture of the measured gas. Communications and zones can be configured based on a plant's individual needs. • Analysis of multiple gases - CO - CO 2 - CH 4 - %C Calculation - Optional H 2 sensor • Analysis of multiple furnace zones (up to 8) • Touch screen interface • Durable sampling system with external pump • Easy mounting of enclosures • Multiple atmosphere and temperature sources can be set up • Adjustable calculation factors based on atmosphere properties • Industry leading technical support • Gas sensors engineered and manufactured by SSi atmosphere
Transcript
Page 1: MZA 6010 - Super Systems · MZA 6010 SuperSystem A18-05132015-001 The MZA 6010 is a Multi-Gas Infrared (IR) analyzer used to analyze gases in multiple zones of a furnace or furnaces.

INNOVATIVE SOLUTIONS WORLDWIDE

sincorporated

MZA 6010

SuperSystem

A18-05132015-001

The MZA 6010 is a Multi-Gas Infrared (IR) analyzer used to analyze gases in multiple zones of a furnace or furnaces. It measures Carbon Monoxide (CO), Carbon Dioxide (CO2) and Natural Gas (CH4) typically found in an endothermic atmosphere. The measurement of these gases, combined with furnace temperature information, allows the MZA 6010 to calculate the percent Carbon (%C) of the measured gas. A Hydrogen (H2) sensor can also be incorporated as an option to provide a more complete picture of the measured gas. Communications and zones can be configured based on a plant's individual needs.

• Analysis of multiple gases - CO - CO2 - CH4 - %C Calculation - Optional H2 sensor• Analysis of multiple furnace zones (up to 8)• Touch screen interface• Durable sampling system with external pump• Easy mounting of enclosures• Multiple atmosphere and temperature sources can be set up• Adjustable calculation factors based on atmosphere properties• Industry leading technical support• Gas sensors engineered and manufactured by SSi

atmosphere

Page 2: MZA 6010 - Super Systems · MZA 6010 SuperSystem A18-05132015-001 The MZA 6010 is a Multi-Gas Infrared (IR) analyzer used to analyze gases in multiple zones of a furnace or furnaces.

7205 Edington DriveCincinnati , OH 45249

513.772.0060 phone513.772.9466 fax

SuperSystemsincorporated

www.supersystems.com 800.666.4330

• Number of zones supported: 8• Gas ranges - CO (range 0.00 to 30.00%) - CO2 (range 0.000 to 2.000%) - CH4 (range 0.00 to 15.00%) - Optional H2 measurement with SSi H2 sensor (range 0.00 to 100%)• Measurement method for CO, CO2, CH4: non-dispersive infrared (NDIR)• Measurement method for H2 (with optional H2 cell): thermal conductivity• Accuracy and repeatability: +/- 1% of full scale• On-board calibration• Communications: Ethernet, USB(A), USB(B), RS485 Modbus• Data storage: Continuous automatic data logging • Operating Temperature: 32°F to 122°F (0°C to 50°C)• External Dimensions: Approx. 16"H X 20"L X 8"D per enclosure

Specifications

ZONE 1 - TEMP ONLY

FURNACE TC MATRIX ZONE 1 TEMP

9205 CONTROLLER

ZONE 2 - TEMP & CP%FURNACE TC

OXYGEN PROBE

WITH TC

CP%

CALCULATION

MATRIX ZONE 2 TEMP

MATRIX ZONE 2 CP%

FURNACE TC

OXYGEN PROBE

WITH TC

CP%

CALCULATION

MATRIX ZONE 3 TEMP

MATRIX ZONE 3 CP%

ENDOTHERMIC GAS

GENERATOR

GENERATOR TC

OXYGEN

PROBE SYSTEM

9205 TEMP CONTROL

9205 DEW

POINT CONTROL

ENDOTHERMIC GAS FLOW

FURNACE CONTROL

MZA COMPARES GENERATOR & ZONE 2,3,4 CP% WITH

3-GAS CP% & ALARMS ON DISCREPANCY, SUGGESTS

COF FOR MANUAL ADJUSTMENT OF ATMOPSHERE CONTROL*

COOLER

CP% DISCREPANCY MONITORING

CP% DISCREPANCY MONITORING

CP% DISCREPANCY MONITORING

BURNOFF

BURNOFF

GAS SAMPLE TO MZA

GAS SAMPLE TO MZA

O2 PROBE REFERENCE/BURNOFF BOX

O2 PROBE REFERENCE/BURNOFF BOX

GAS SAMPLE TO MZA

FURNACE

ZONE 3 - TEMP & CP%

FURNACE TC

OXYGEN PROBE

WITH TC

CP%

CALCULATION

MATRIX ZONE 4 TEMP

MATRIX ZONE 4 CP%

CP% DISCREPANCY MONITORING

GAS SAMPLE TO MZA

O2 PROBE REFERENCE/BURNOFF BOX

ZONE 4 - TEMP & CP%

*Not required - monitoring/auto-correct system

operates independently of

primary carbon potential system

EXAMPLE SCHEMATIC INCLUDING MZA 6010


Recommended