© 2011 Underwriters Laboratories Inc. National Industrial Security Systems (UL 2050) 5 th Edition November 5, 2010 JSAC April 2017
Transcript
Page 1: National Industrial Security Systems (UL 2050) 5 Edition …jsac-dfw.org/Presentations_2017/UL2050 Certification.pdf · 2017. 4. 14. · Systems (UL 2050) 5th Edition November 5,

© 2011 Underwriters Laboratories Inc.

National Industrial Security Systems (UL 2050) 5th

Edition November 5, 2010

JSAC April 2017

Page 2: National Industrial Security Systems (UL 2050) 5 Edition …jsac-dfw.org/Presentations_2017/UL2050 Certification.pdf · 2017. 4. 14. · Systems (UL 2050) 5th Edition November 5,

The Origin of the Program

• Purpose• Partnership• Flexibility of Application

– Rational – Cost Effective– Threat Appropriate

Page 3: National Industrial Security Systems (UL 2050) 5 Edition …jsac-dfw.org/Presentations_2017/UL2050 Certification.pdf · 2017. 4. 14. · Systems (UL 2050) 5th Edition November 5,

Documents Defining Security

National Industrial Security Systems ,UL 2050National Industrial Security Systems ProgramOperating Manual (NISPOM)Director of Central Intelligence Directive 6/9 (DICD 6/9) (Now ICS 705-1)Manual for Physical Security of SensitiveConventional Arms, Ammunition, and Explosives

(DoD 5100.76-M)Joint Air Force Army Navy Physical Security

Manual 6/9 (JAFAN 6/9)

3

Page 4: National Industrial Security Systems (UL 2050) 5 Edition …jsac-dfw.org/Presentations_2017/UL2050 Certification.pdf · 2017. 4. 14. · Systems (UL 2050) 5th Edition November 5,

US Government Representatives

Cognizant Security Office

•Applies when areas being protected are controlled by the Defense Security Service

Cognizant Security Agency

•Applies when areas being protected are controlled by other US Government organizations such as the intelligence community (soon to be known as Accrediting Official-see ICD-705)

4

Page 5: National Industrial Security Systems (UL 2050) 5 Edition …jsac-dfw.org/Presentations_2017/UL2050 Certification.pdf · 2017. 4. 14. · Systems (UL 2050) 5th Edition November 5,

Role of the CSO/CSA

• Define the Minimum Features of the IDS• Provide Prior Approval of Variables• Approve Security in Depth (SID) where

applicable• Confirm Clearances where Required• Coordinate with Contractor and Alarm Company

on non-technical IDS issues• Coordinate with UL Representatives

5

Page 6: National Industrial Security Systems (UL 2050) 5 Edition …jsac-dfw.org/Presentations_2017/UL2050 Certification.pdf · 2017. 4. 14. · Systems (UL 2050) 5th Edition November 5,

Role of the UL Auditor

National Industrial Security Systems (CRZH)

• To Audit ASC’s that have requested UL Certificates for Compliance with UL 681 & UL 2050

National Industrial Monitoring Station (CRZM)

• To Audit Government Contractors or Central Stations that have established a Listing for Compliance with UL 2050

6

Page 7: National Industrial Security Systems (UL 2050) 5 Edition …jsac-dfw.org/Presentations_2017/UL2050 Certification.pdf · 2017. 4. 14. · Systems (UL 2050) 5th Edition November 5,

UL 2050

How Standards are Created

• UL Staff Designated as Primary Engineer

• Work with Key Stakeholders

• Consider Proposed Requirements

How Standards are Maintained

• Input from Key Stakeholders

• UL Develop Proposed Revisions

• Consider Proposals

7

Page 8: National Industrial Security Systems (UL 2050) 5 Edition …jsac-dfw.org/Presentations_2017/UL2050 Certification.pdf · 2017. 4. 14. · Systems (UL 2050) 5th Edition November 5,

National Industrial Security Systems(CRZH)

8

Page 9: National Industrial Security Systems (UL 2050) 5 Edition …jsac-dfw.org/Presentations_2017/UL2050 Certification.pdf · 2017. 4. 14. · Systems (UL 2050) 5th Edition November 5,

Who Is Responsible

9

• 4.3 of UL 2050• ASC may assign monitoring &

investigation but retain responsibility• ASC may assign installation & service

provided they supervise & verify correctness

• ASC may assign maintenance, but only to personnel that work exclusively for the ASC Service Center

Page 10: National Industrial Security Systems (UL 2050) 5 Edition …jsac-dfw.org/Presentations_2017/UL2050 Certification.pdf · 2017. 4. 14. · Systems (UL 2050) 5th Edition November 5,

Assigning Elements of Service

10

Alarm Service CompanyCorrectness of Installation

Service & MaintenanceTraining & Performance of

Monitor & Investigator

MonitoringGovernment Contractor

Monitoring Station (GCMS)or

National IndustrialMonitoring Station

or UL Central Station

orLaw Enforcement

InvestigationGovernment Contractor Investigator

orPrivate Guard &

Government Contractor Rep.or

Law Enforcement & Government Contractor Rep.

orGovernment Contractor Rep.

Page 11: National Industrial Security Systems (UL 2050) 5 Edition …jsac-dfw.org/Presentations_2017/UL2050 Certification.pdf · 2017. 4. 14. · Systems (UL 2050) 5th Edition November 5,

Impact of Security In Depth

Reduces electrical supervision of remote equipment rooms when a GCMS is used

(Does Not Apply When Areas Housing AA&E Are Monitored or DCID applies)Reduces standby power requirements when a GCMS is used

(except SCIF’s and SAPF’s)

Allows the use of an Extent 5 design of protection in closed areas(Does Not Apply to Areas Housing AA&E or When DCID applies)

11

Page 12: National Industrial Security Systems (UL 2050) 5 Edition …jsac-dfw.org/Presentations_2017/UL2050 Certification.pdf · 2017. 4. 14. · Systems (UL 2050) 5th Edition November 5,

Features Requiring Prior Approval

Use of Extent 5* vs. Extent 3• *Extent 5 only applies to the NISPOM

Non Line Security Transmission Use of Data NetworksOnly Monitoring Alarm & Trouble SignalsMonitoring in a Law Enforcement AgencyInvestigator Response PersonnelResponse Times beyond 5 or 15 Minutes

12

Page 13: National Industrial Security Systems (UL 2050) 5 Edition …jsac-dfw.org/Presentations_2017/UL2050 Certification.pdf · 2017. 4. 14. · Systems (UL 2050) 5th Edition November 5,

Government Contractor Monitoring StationPurpose - to monitor industrial security systems

that are installed in the following areas:

• Areas occupied by the government contractor that operates the GCMS

• Areas occupied by a subcontractor

• Areas occupied by other government contractors

The station is verified & receivers are maintained by the ASC

13

Page 14: National Industrial Security Systems (UL 2050) 5 Edition …jsac-dfw.org/Presentations_2017/UL2050 Certification.pdf · 2017. 4. 14. · Systems (UL 2050) 5th Edition November 5,

National Industrial Monitoring StationPurpose - to monitor industrial security systems

installed in the following areas that are more than 4 hours away from the monitoring station:

–Areas occupied by the government contractor that operates the NIMS

–Areas occupied by a subcontractor

–Areas occupied by other government contractors

14

Page 15: National Industrial Security Systems (UL 2050) 5 Edition …jsac-dfw.org/Presentations_2017/UL2050 Certification.pdf · 2017. 4. 14. · Systems (UL 2050) 5th Edition November 5,

Commercial UL Central Stations ProvideMonitoring of Alarm System

• (operators & station may have to be cleared)Processing of Signals & Creation of RecordsDispatching InvestigatorsPeriodic Testing of Communication Links to Investigators

15

Page 16: National Industrial Security Systems (UL 2050) 5 Edition …jsac-dfw.org/Presentations_2017/UL2050 Certification.pdf · 2017. 4. 14. · Systems (UL 2050) 5th Edition November 5,

Signal Processing in GCMS, NIMS, or a Central Station

Record each of the following types of signals

• Openings & Closings

• Alarms

• Troubles

Maintain current lists of the following

• Authorized operators of the system

• Personnel to be notified of an alarm

• The FSO/SSO

• Service department personnel in the alarm service company that maintains the system

16

Page 17: National Industrial Security Systems (UL 2050) 5 Edition …jsac-dfw.org/Presentations_2017/UL2050 Certification.pdf · 2017. 4. 14. · Systems (UL 2050) 5th Edition November 5,

Law-Enforcement Agency or Public Emergency Center

Requires Prior Approval by CSO/CSA

Monitors System for Alarms & Trouble Conditions

Dispatches Investigators

Receivers are maintained by a UL Listed Alarm Service Company

17

Page 18: National Industrial Security Systems (UL 2050) 5 Edition …jsac-dfw.org/Presentations_2017/UL2050 Certification.pdf · 2017. 4. 14. · Systems (UL 2050) 5th Edition November 5,

Alarms & Unauthorized Openings (Sec 12)

Contact-alarmed areaVerification-speak to authorized user

•Late or None- During business hours CALL FSO/SSO

- After business hours DISPATCH

•Timely Verification- During business hours CALL FSO/SSO

- After business hours REPORT TO FSO/SSO

18

Page 19: National Industrial Security Systems (UL 2050) 5 Edition …jsac-dfw.org/Presentations_2017/UL2050 Certification.pdf · 2017. 4. 14. · Systems (UL 2050) 5th Edition November 5,

Follow UP to Alarm Signal

If the system resets in 1 minute• Dispatch a single investigator who has access to the

exterior of alarmed area

• Technician inspects area within 4 hours of facility opening for business

After verification• When open for business, report to FSO/SSO by voice

and in writing

• When closed for business, report to FSO/SSO in writing

19

Page 20: National Industrial Security Systems (UL 2050) 5 Edition …jsac-dfw.org/Presentations_2017/UL2050 Certification.pdf · 2017. 4. 14. · Systems (UL 2050) 5th Edition November 5,

Investigators

Government contractor investigators cleared & with unescorted access

Private guards without unescorted access and a representative of the government contractor

On-duty law-enforcement officer and a representative of the government contractor

A representative of the government contractor having authorized access

20

*

*

*Requires Prior Approval by CSO/CSA

Page 21: National Industrial Security Systems (UL 2050) 5 Edition …jsac-dfw.org/Presentations_2017/UL2050 Certification.pdf · 2017. 4. 14. · Systems (UL 2050) 5th Edition November 5,

Details

If Government Contractor Representatives are used

•3 people shall be on call

•The name & phone number of the FSO/SSO shall be maintained

•The phone numbers shall be verified in writing every 90 days

21

Page 22: National Industrial Security Systems (UL 2050) 5 Edition …jsac-dfw.org/Presentations_2017/UL2050 Certification.pdf · 2017. 4. 14. · Systems (UL 2050) 5th Edition November 5,

Response Teams & Times

22

Primary Investigator Secondary Investigator

Response Times

Government Contractor Investigator

None 5, 15, 20, or 30*

Private Guard (without unescorted

access)

Government Contractor

Representative

5, 15, 20, or 30 (Primary), 60 min for

Representative Law Enforcement Government

Contractor Representative

No Time Stated for Primary,

60 Min for Representative

Government Contractor Representative

None 60 Minutes

*Requires prior approval by CSO/CSA

Page 23: National Industrial Security Systems (UL 2050) 5 Edition …jsac-dfw.org/Presentations_2017/UL2050 Certification.pdf · 2017. 4. 14. · Systems (UL 2050) 5th Edition November 5,

Auditing Alarm Records

Records are held at ASC office or at the Government Contractor officeReview is conducted on responses to each individual alarm systemThe calculation of the percentage of overruns starts at the fifth alarmNo arrival results in a cause analysis

23

Page 24: National Industrial Security Systems (UL 2050) 5 Edition …jsac-dfw.org/Presentations_2017/UL2050 Certification.pdf · 2017. 4. 14. · Systems (UL 2050) 5th Edition November 5,

Communication Channel Failures

Attempted Compromise (See Sec 13)

• Treated as an Alarm if System is Armed

• Treated as a Trouble if System is Disarmed

Disruption of Channel (See Sec 14)

• Applies when Channel Serves More that 1 System

- Contact Communication Provider

- Contact FSO/SSO

24

Page 25: National Industrial Security Systems (UL 2050) 5 Edition …jsac-dfw.org/Presentations_2017/UL2050 Certification.pdf · 2017. 4. 14. · Systems (UL 2050) 5th Edition November 5,

Upon Arrival and Beyond

No Cause Was Found -

• Test and Reset by Investigator

- Checked by service technician within 4 hours of opening of the facility.

• Not Reset by Investigator

- Area check by investigator and service technician dispatched

25

Page 26: National Industrial Security Systems (UL 2050) 5 Edition …jsac-dfw.org/Presentations_2017/UL2050 Certification.pdf · 2017. 4. 14. · Systems (UL 2050) 5th Edition November 5,

Trouble Signals & Service Calls

Occupied or Checked AreasInitiate repairs within 4 hours after facility opens if

- Area is occupied by a person with authorized access OR

- Area is checked by cleared personnel based on NISPOM

Not Occupied or Checked Areas• Initiate repairs within 4 hours

26

Page 27: National Industrial Security Systems (UL 2050) 5 Edition …jsac-dfw.org/Presentations_2017/UL2050 Certification.pdf · 2017. 4. 14. · Systems (UL 2050) 5th Edition November 5,

ContractsWhen monitoring and/or investigation is assigned(See 18.1 & 18.2)30 Day cancellation clauseDD254 is required if monitoring or investigation isassigned to a central station AND the NISPOMapplies (See 18.3)Contracts do not relieve the Alarm ServiceCompany from keeping the alarm and monitoringsystems in compliance (see 18.4)Failure to uphold the contracts – Cancel Certificate(See 18.6)

27

Page 28: National Industrial Security Systems (UL 2050) 5 Edition …jsac-dfw.org/Presentations_2017/UL2050 Certification.pdf · 2017. 4. 14. · Systems (UL 2050) 5th Edition November 5,

Training

The ASC is responsible to arrange for and/or verifyTraining

Training shall be conducted annually or whenthere is a change

The ASC shall keep a record of the specifictraining and the name of who was trained.

28

Page 29: National Industrial Security Systems (UL 2050) 5 Edition …jsac-dfw.org/Presentations_2017/UL2050 Certification.pdf · 2017. 4. 14. · Systems (UL 2050) 5th Edition November 5,

Conducting a Service Test

During business hours

•Trip a signal at an unoccupied area- Verification

- Dispatch

After business hours (rarely done)

•Trip a signal with FSO/SSO

• Initiate a telephone test- Dispatch

29

Page 30: National Industrial Security Systems (UL 2050) 5 Edition …jsac-dfw.org/Presentations_2017/UL2050 Certification.pdf · 2017. 4. 14. · Systems (UL 2050) 5th Edition November 5,

Security of Communication Channels

Communication paths from the alarmed area to the monitoring center are as important as the installation

Line Security -The supervision against compromise using 2 way communicationMay be either Standard or Encrypted

Non-Line Security - (Requires prior approval by CSO/CSA)

The supervision of a single fault condition on the communication path

Exists when there is 1 way communication30

Page 31: National Industrial Security Systems (UL 2050) 5 Edition …jsac-dfw.org/Presentations_2017/UL2050 Certification.pdf · 2017. 4. 14. · Systems (UL 2050) 5th Edition November 5,

Security of Communication Channels

Transmission methods that provide Line Security -2 Way Radio FrequencyData Networks

Transmission methods that do not provide Line Security -

Digital CommunicatorsCellular Transmitters* (Some do provide line

security-check the Listing)1 Way Radio Frequency

31

Page 32: National Industrial Security Systems (UL 2050) 5 Edition …jsac-dfw.org/Presentations_2017/UL2050 Certification.pdf · 2017. 4. 14. · Systems (UL 2050) 5th Edition November 5,

Requirements for Encryption

Certified by NIST

• At least 128 Bit Encryption

• Complying with FIPS 140-2 OR FIPS-197

Listed by UL as Line Security Equipment

Generally Required by the CSO/CSA When Data Networks are used

32

Page 33: National Industrial Security Systems (UL 2050) 5 Edition …jsac-dfw.org/Presentations_2017/UL2050 Certification.pdf · 2017. 4. 14. · Systems (UL 2050) 5th Edition November 5,

Degraded Network

If the network becomes degraded or inoperative, the areas have to be watched or occupied

Service response times and notification in accordance with Sec 14 of UL 2050

33

Page 34: National Industrial Security Systems (UL 2050) 5 Edition …jsac-dfw.org/Presentations_2017/UL2050 Certification.pdf · 2017. 4. 14. · Systems (UL 2050) 5th Edition November 5,

Alarm Installations

Installed in Closed Areas, SCIF’s or SAPF’s

• Extent 5 (Only Applies to Closed Areas under the NISPOM)

• Extent 3

Installed in Vaults or on Container

• Extent Complete

34

Page 35: National Industrial Security Systems (UL 2050) 5 Edition …jsac-dfw.org/Presentations_2017/UL2050 Certification.pdf · 2017. 4. 14. · Systems (UL 2050) 5th Edition November 5,

Extent of Protection #3

Area B

contact on exterior door4 step motion

Area A contact on exterior door4 step motion

Movable Windows

A

B

Using Motion Detection

Page 36: National Industrial Security Systems (UL 2050) 5 Edition …jsac-dfw.org/Presentations_2017/UL2050 Certification.pdf · 2017. 4. 14. · Systems (UL 2050) 5th Edition November 5,

Extent of Protection #3

Area B contact on exterior doorcontact 1 windowmotion to cover door & windowglass break on 2 windows

Area A contact on exterior doormotion to cover doorglass break on 3 windows

Movable Windows

A

B

Using Perimeter Protection

Page 37: National Industrial Security Systems (UL 2050) 5 Edition …jsac-dfw.org/Presentations_2017/UL2050 Certification.pdf · 2017. 4. 14. · Systems (UL 2050) 5th Edition November 5,

Protection of Containers & Vaults

Extent Partial consists of a contact that is Listed for safe & vault applications on each door. One contact may be used on GSA approved containers.

Extent Complete consists of a contact that is Listed for safe & vault applications on each door. One contact may be used on GSA approved containers. In addition all exterior surfaces of the vault or container is protected with vibration sensors or proximity detectors.

37

Page 38: National Industrial Security Systems (UL 2050) 5 Edition …jsac-dfw.org/Presentations_2017/UL2050 Certification.pdf · 2017. 4. 14. · Systems (UL 2050) 5th Edition November 5,

National Industrial Monitoring Stations (CRZM)

38

Page 39: National Industrial Security Systems (UL 2050) 5 Edition …jsac-dfw.org/Presentations_2017/UL2050 Certification.pdf · 2017. 4. 14. · Systems (UL 2050) 5th Edition November 5,

Origin of Category

To develop a means of determining the qualification of a monitoring location that is distant from the protected property

To clarify the responsibility for the continued compliance of the monitoring facility

39

Page 40: National Industrial Security Systems (UL 2050) 5 Edition …jsac-dfw.org/Presentations_2017/UL2050 Certification.pdf · 2017. 4. 14. · Systems (UL 2050) 5th Edition November 5,

A Listing is Required When -

The station is not within the 4 hour service territory of the ASC service center to which the certificate was provided

The station is maintained by another ASC service center

40

Page 41: National Industrial Security Systems (UL 2050) 5 Edition …jsac-dfw.org/Presentations_2017/UL2050 Certification.pdf · 2017. 4. 14. · Systems (UL 2050) 5th Edition November 5,

Auditing a National Industrial Monitoring Station

41

Page 42: National Industrial Security Systems (UL 2050) 5 Edition …jsac-dfw.org/Presentations_2017/UL2050 Certification.pdf · 2017. 4. 14. · Systems (UL 2050) 5th Edition November 5,

The Purpose

An NIMS has been evaluated for compliance with Section 6 & 7 of UL 2050 (when operated by a government contractor) or UL 827 as a Central Station (when operated by an ASC)

The Audit is to verify

• The facility continues to comply

• The staff performs the required tests

• The staff is trained in their duties

42

Page 43: National Industrial Security Systems (UL 2050) 5 Edition …jsac-dfw.org/Presentations_2017/UL2050 Certification.pdf · 2017. 4. 14. · Systems (UL 2050) 5th Edition November 5,

The UL Alarm System Description Form

43

Page 44: National Industrial Security Systems (UL 2050) 5 Edition …jsac-dfw.org/Presentations_2017/UL2050 Certification.pdf · 2017. 4. 14. · Systems (UL 2050) 5th Edition November 5,

44

Page 45: National Industrial Security Systems (UL 2050) 5 Edition …jsac-dfw.org/Presentations_2017/UL2050 Certification.pdf · 2017. 4. 14. · Systems (UL 2050) 5th Edition November 5,

45

Page 46: National Industrial Security Systems (UL 2050) 5 Edition …jsac-dfw.org/Presentations_2017/UL2050 Certification.pdf · 2017. 4. 14. · Systems (UL 2050) 5th Edition November 5,

46

Page 47: National Industrial Security Systems (UL 2050) 5 Edition …jsac-dfw.org/Presentations_2017/UL2050 Certification.pdf · 2017. 4. 14. · Systems (UL 2050) 5th Edition November 5,

47

Page 48: National Industrial Security Systems (UL 2050) 5 Edition …jsac-dfw.org/Presentations_2017/UL2050 Certification.pdf · 2017. 4. 14. · Systems (UL 2050) 5th Edition November 5,

48

Page 49: National Industrial Security Systems (UL 2050) 5 Edition …jsac-dfw.org/Presentations_2017/UL2050 Certification.pdf · 2017. 4. 14. · Systems (UL 2050) 5th Edition November 5,

UL Certificate Service Territories forAlarm Systems and Services

ND

MO

AR

#

NY

AK

HI

WA

CA

NV

OR ID

MT

WY

UT

AZ NM

TX

OK

KS

NE

SD

MN

IA

WI

IL

LA

MS AL GA

FL

SC

NCTN

KY

IN

MI

OH

VA

WV DE

MD

NJ

CTMA

VT

NH

ME

CO

Puerto Rico

US Virgin Islands

East

West

Midwest

Washington, D.C.

PA

Regional ContactsMid West: Joe Weller 847 664 2368East Coast Pete Tallman 631 546 2415

Additional Contact for Texas area is Nick Mirus 972-509-1294


Recommended