National Radio Astronomy Observatory VLA Electronics Memo No. 220 Cathodic Protection of the VLA 60mm Waveguide: Natural Potentials versus Applied Potentials Rudy Latasa September 1992 A corrosion survey of the underground waveguide at the VLA was conducted in May of 1980 and completed in March of 1981. At that time a recommendation was made by Pacific Corrosion Research, Inc. that a cathodic protection system should be installed. Due to the high current demand and the cost, it was unfeasible to consider the sacrificial anode so the impressed current system was installed. Common criteria for protection of buried steel from corrosion required a minimum of -300 millivolt and an ideal of -800 millivolt potential relative to natural potential (steel-to- ground) . The measured waveguide-to-soil natural potential ranged from -400 mv to -600 mv on the north and east arms. The measured west arm natural potential from A0 to A7 was in the range of -400 mv to -500 mv while the potential reading from W8 to W38 was in the range of -100 mv to -200 mv. The consultant calculated that the total current required to give us minimum protection would be 288 amperes. This calculation was done on seventy-two observing stations, approximately 60km of 60mm underground waveguide, and the railroad track. The installed cathodic protection system consists of 11 air cooled rectifiers, 186 each 4” x 40” graphite anodes, and 35 each 4” x 4” x 56" sacrificial magnesium anodes. The magnesium anodes were used in areas, such as road crossings and some underground tanks, where active applied potential was not feasible. The attached graphs show the measured applied potentials (AP) and measured natural potentials (NP) at each manhole on each arm. The graphs also show the minimum natural potential, minimum protected potential and the ideal protected potential. One set of graphs compare the 1980 natural versus the 1984 applied potentials. The second set compares the 1980 natural versus the 1990 applied potentials. A third set compares the 1990 applied potentials versus the 1992 natural potentials. In 1992 a break in the power cable between manholes E3 and E4 allowed us to take some natural potential readings after power had been down for 3 months. 1
Transcript
Page 1: National Radio Astronomy Observatory VLA Electronics …VLA Electronics Memo No. 220 Cathodic Protection of the VLA 60mm Waveguide: Natural Potentials versus Applied Potentials Rudy

National Radio Astronomy Observatory VLA Electronics Memo No. 220

Cathodic Protection of the VLA 60mm Waveguide:Natural Potentials versus Applied Potentials

Rudy Latasa September 1992

A corrosion survey of the underground waveguide at the VLA was conducted in May of 1980 and completed in March of 1981. At that time a recommendation was made by Pacific Corrosion Research, Inc. that a cathodic protection system should be installed. Due to the high current demand and the cost, it was unfeasible to consider the sacrificial anode so the impressed current system was installed.

Common criteria for protection of buried steel from corrosion required a minimum of -300 millivolt and an ideal of -800 millivolt potential relative to natural potential (steel-to- ground) . The measured waveguide-to-soil natural potential ranged from -400 mv to -600 mv on the north and east arms. The measured west arm natural potential from A0 to A7 was in the range of -400 mv to -500 mv while the potential reading from W8 to W38 was in the range of -100 mv to -200 mv.

The consultant calculated that the total current required to give us minimum protection would be 288 amperes. This calculation was done on seventy-two observing stations, approximately 60km of 60mm underground waveguide, and the railroad track. The installed cathodic protection system consists of 11 air cooled rectifiers, 186 each 4” x 40” graphite anodes, and 35 each 4” x 4” x 56" sacrificial magnesium anodes. The magnesium anodes were used in areas, such as road crossings and some underground tanks, where active applied potential was not feasible.

The attached graphs show the measured applied potentials (AP) and measured natural potentials (NP) at each manhole on each arm. The graphs also show the minimum natural potential, minimum protected potential and the ideal protected potential. One set of graphs compare the 1980 natural versus the 1984 applied potentials. The second set compares the 1980 natural versus the 1990 applied potentials. A third set compares the 1990 applied potentials versus the 1992 natural potentials. In 1992 a break in the power cable between manholes E3 and E4 allowed us to take some natural potential readings after power had been down for 3 months.

1

Page 2: National Radio Astronomy Observatory VLA Electronics …VLA Electronics Memo No. 220 Cathodic Protection of the VLA 60mm Waveguide: Natural Potentials versus Applied Potentials Rudy

The natural potentials taken on the east arm between manholes E22 and E37 looked much better in 1992 than they did in the original 1980 survey. Comparing the 1984 applied potentials to the 1990 applied potentials, the 1990 graphs show some noticeable gain in the amount of protection on each arm. The amount of maintenance and watering that was done in the last two years may account for much of this increase. Although some areas didn't show much of an increase, it may be due to poor grounding on the waveguide. This is something we'll have to look at as time permits. According to the graphs from 1984, the waveguide had at least the minimum protection of -300 mv. The 1990 graphs show most of the underground waveguide has the ideal protection of -800 mv.

Acknowledgement: James Guin, and Rey Serna measured the 1980 potentials. James Guin and John Leo Sanchez measured the 1984 potentials. James Guin and the cryogenic group measured the 1990 and 1992 potentials.

Reference: Corrosion Survey by Heaven Tso, Chief Engineer, Pacific Corrosion Research, Inc.

2

Page 3: National Radio Astronomy Observatory VLA Electronics …VLA Electronics Memo No. 220 Cathodic Protection of the VLA 60mm Waveguide: Natural Potentials versus Applied Potentials Rudy

Natu

ral

Pote

ntia

l Vo

lts

Natu

ral

Pote

ntia

l Vo

lts

Natu

ral

Pote

ntia

l Vo

lts

Applied Versus Natural PotentialWest Arm 1980 natural and 1984 Applied

21.81.61.4-1.2-

10.80.6-

0.4-0.2

Min. Protected Potential deal Protected Potential

i j

I

.-300 MV

1 y y if i A0 1 2 3 4 5 6 7 8 9 10 11 12

2 1.8 1.6

H1.4 1.2

0.8 * -0.6 ^

-0.4 0.2 0

I

ManhoIes(Rectifier 6=1 lamps) Mjn Nat Potential

21.8-

1.6-

1.41.2-

1 -

0.8-

0.6-

0.4-0.20

Min. Protected Potential

.-300 MV

Ideal Protected Potential

i

13 14 15 16 17 18 19 20 21 22 23 24 Manholes(Rectifier 14=9 amps)

2 1.8

b1.6 1-1.4 1.2 10.8 0.6 o

-0.4 §0.2 4*-

1-0

£>£•S?c.2oCL

Min. Nat Potential

21. 8-

1.6-1.4-1.2-

1-

0.8-

0.60.4-0.2-0

Min. Protected Potential Ideal Protected Potential

.-300 MV

25 26 27 28 29 30 31 32 33 34 35 36 37 38 Manholes(Rectifier 26= 12amps)

21.81.6

h1.41.210.80.60.40.20

&

#

Natural

Min. Nat Potential

South NP South AP

Manhole NP Manhole AP

North NP North AP' Applied

3

Page 4: National Radio Astronomy Observatory VLA Electronics …VLA Electronics Memo No. 220 Cathodic Protection of the VLA 60mm Waveguide: Natural Potentials versus Applied Potentials Rudy

Natu

ral

Pote

ntia

l Vo

lts

Natu

ral

Pote

ntia

l Vo

lts

Natu

ral

Pote

ntia

l Vo

lts

Applied Versus Natural PotentialWest Arm 1980 and 1990 Applied

Manhole (Rectifier 6=10 Amps)

Min. Nat Potential

WKmmwn13 14 15 16 17 18 19 20 21 22 23 24

Manhole (Rectifier 14=10.5 amps)

Min. Nat Potential

4

Page 5: National Radio Astronomy Observatory VLA Electronics …VLA Electronics Memo No. 220 Cathodic Protection of the VLA 60mm Waveguide: Natural Potentials versus Applied Potentials Rudy

Applied Versus Natural PotentialNorth Arm 1980 Natural and Applied 1984

r2-1.8-1.6 o-1.4-1.2

.(0c-

-1 -0 8

Q>oCL

-0.6O,g>

-0.4 Q.Q-0.2

Manholes(Rectifier 1=7.5 & 7=7 Amp&±-Min. Nat Potential

o>c<D•+<*«OCL5=3•4̂ *5

•aTO■EjcCDH-w0•o0)1

13 14 15 16 17 18 19 20 21 22 23 24 Manholes(Rectifier 13 & 24ea. = 9.5 Amps

Min. Nat Potentia

25 26 27 28 29 30 31 32 33 34 35 Manholes

Min. Nat Potential

Natural ^ South NP m Manhole NP ^ North NP

Applied

5

Page 6: National Radio Astronomy Observatory VLA Electronics …VLA Electronics Memo No. 220 Cathodic Protection of the VLA 60mm Waveguide: Natural Potentials versus Applied Potentials Rudy

Applied Versus Natural PotentialNorth Arm 1980 and 1990 Applied

2 8-

6-

4- 2 1 8 6̂

•2 0.4

*2 1 . 1. 1. 1.

o

.to-Cnc<DOCL5-2TO

O-l

Min. Protected Potential

.-300 MV

Ideal Potected Potential

0 1 2 3 4 5 6 7 8 9 10 11 12 Manhole(Rectifier 7=22 amps)

2 (-1.8

1.6 K 1.4 - 1.2 -1- 0.8 £

-0.6 ? 0.4 U 0.2

-J2§TOc:9>

Min. Nat Potential

£2-t

1.8-2 1.6-TO 1.4-c 1.2-£ 1-oCL 0.8-5 0.6-

§0.4-0.2-

Min. Protected Potential Ideal Protected Potential

r

13 14 15 16 17 18 19 20 21 22 23 24 Manhole(Rectifier 13=8.75 & 24=13 amps)

Min. Nat Potential

£I

c:£oQ.!§

25 26 27 28 29 30 31 32 33 34 35 Manhole(Rectifier 13=8.75 & 24=13 amps)

Min. Nat Potential

Natural §§ South NP ■■ Manhole NP North NP

m ill Ha ^ S s'J t& Y v ia Applied

6

Page 7: National Radio Astronomy Observatory VLA Electronics …VLA Electronics Memo No. 220 Cathodic Protection of the VLA 60mm Waveguide: Natural Potentials versus Applied Potentials Rudy

Applied Versus Natural PotentialEast Arm 1980 Natural and 1984 Applied

Min. Nat Potential

0 1 2 3 4 5 6 7 8 9 10 11 12 Manholes(Rectifiers 3=5.5 & 8=8)

co*4—jOCL

£§

i2

c:oa.<D£

Min. Protected Potential Ideal Protected Potential

13 14 15 16 17 18 19 20 21 22 23 24 Manholes(Rectifiers 15= 11 AMPS)

Min. Nat Potential

25 26 27 28 29 30 31 32 33 34 35 Manholes(Rectifier 25=30 amps)

Min. Nat Potential

NATURAL East NP East AP

Manhole NP Manhole AP

West NP West AP. APPLIED

7

Page 8: National Radio Astronomy Observatory VLA Electronics …VLA Electronics Memo No. 220 Cathodic Protection of the VLA 60mm Waveguide: Natural Potentials versus Applied Potentials Rudy

Natu

ral

Pote

ntia

l Vo

lts

Ideal Protected Potential

§c:■So

Applied Versus Natural PotentialsEast Arm 1980 Natural and 1990 Applied

1 2 3 4 5 6 7 8 9 10 11 12 Manholes (Rectifier 8=12.75) Min Nat Potential

- 0.8

Min. Protected Potential

Min. Protected Potential Ideal Protected Potential

13 14 15 16 17 18 19 20 21 22 23 24 Manholes(Rectifier 15=1 lamps 24=18amps)

- 1.8- 1.61.41.21

- 0.8 - 0.6

4 hO.2 0

£sIs■isc:£0 CL“Cl.<D1

Min. Nat Potential

2i

f2 1.8-

s 1.6-1.4-

1.2-1-

Q. 0.8-

1 0.6-

30.4-0.2-

25 26 27 28 29 30 Manholes

32 33

Min. Nat Potential

West NP

West AP

Manhole NP

Manhole AP

East NP

East AP

§.wc:£0 CL

CD

1

applied

Page 9: National Radio Astronomy Observatory VLA Electronics …VLA Electronics Memo No. 220 Cathodic Protection of the VLA 60mm Waveguide: Natural Potentials versus Applied Potentials Rudy

APPLIED VERSUS NATURAL POTENTIALBAST ARM T990 APPLIED AND 1992 NATURAL

VO

£2o

K

1oQ.

*gK

2

Min. Protected Potential

A Ideal Protected Potential

22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 Manholes (Rectifier @25= 18 AmpsJ

1.8 £

/IMA/HOLES A/P EAST 7CO FT NP MANHOLEAP EAST 100 FT AP


Recommended