National Reminders-National Reminders-Diabetic MicroalbuminDiabetic Microalbumin
Introduction
• The national reminders are in Patch 1005 of clinical reminders.
• The site manager should load this patch at your site.
• This will put all the national reminders into the Reminder Exchange file.
• Reminders should be installed by site manager and a CAC since some require the @ sign level of access
Preparation
• Document pxrm0150.1005o contains the setup of each reminder.
• Check the taxonomy
• Check for reminder terms
• Check for orders
Create Quick Order
• This reminder uses a quick order in the reminder dialog
• Section 5.4 page 40 in pxrm0150.1005o has list of quick orders to make
• LRZ MICROALBUMIN is the name the reminder will be looking for
Quick OrderSelect Order Menu Management Option: QO Enter/edit quick ordersSelect QUICK ORDER NAME: LRZ MICROALBUMIN 1 LRZ MICROALBUMIN 2 LRZ MICROALBUMIN TOMORROWCHOOSE 1-2: 1 LRZ MICROALBUMINNAME: LRZ MICROALBUMIN//DISPLAY TEXT: Microalbumin//VERIFY ORDER:DESCRIPTION: No existing text Edit? NO//ENTRY ACTION:
Quick OrderLab Test: MICROALBUMIN DEMO//Collected By: Send patient to lab//Collection Sample: URINE//Collection Date/Time: TODAY//How often: ONCE//Indication://Indication ICD9:// May decide to enter diabetes diagnosis here ------------------------------------------------------------------------------- Lab Test: MICROALBUMIN DEMO Collected By: Send patient to lab Collection Sample: URINE Specimen: URINE Collection Date/Time: TODAY How often: ONCE------------------------------------------------------------------------------- (P)lace, (E)dit, or (C)ancel this quick order? PLACE//Auto-accept this order? NO//
Reminder Exchange – Install Reminder
• Choose IHS-DIAB MICROALBUMIN 2007
Reminder Installation
• Select IFE to install the reminder
• Review the reminder• Select IA to install all
the components
Install the ComponentsREMINDER TAXONOMY entry IHS-DIABETES DX 2007
already EXISTS,what do you want to do? Select one of the following: C Create a new entry by copying to a new name I Install or Overwrite the current entry Q Quit the install S Skip, do not install this entry Enter response: S//
Error on Taxonomy
• If there is an error in the taxonomy, you need to build it manually
• The screen shows what this error would look like
• Use the pxrm0150.1005o document to determine what codes are in this taxonomy.
REMINDER TAXONOMY entry IHS-ASTHMA 2007 is NEW,what do you want to do? Select one of the following: C Create a new entry by copying to a new name I Install or Overwrite the current entry Q Quit the install S Skip, do not install this entry Enter response: I// nstall or Overwrite the current entryThe update failed, UPDATE^DIE returned the following error
message:MSG("DIERR")=1^1MSG("DIERR",1)=701MSG("DIERR",1,"PARAM",0)=3MSG("DIERR",1,"PARAM",3)=493.02MSG("DIERR",1,"PARAM","FIELD")=.01MSG("DIERR",1,"PARAM","FILE")=811.23102MSG("DIERR",1,"TEXT",1)=The value '493.02 ' for field
SELECTABLE DIAGNOSIS in SELECTABLE DIAGNOSIS SUB-FIELD in file REMINDER
TAXONOMY is not valid.MSG("DIERR","E",701,1)= REMINDER TAXONOMY entry IHS-ASTHMA 2007 did not get
installed!Examine the above error message for the reason.
Taxonomy Creation
Taxonomy CreationNAME: IHS-DIABETES DX 2007 ReplaceBRIEF DESCRIPTION: CLASS: LOCAL//SPONSOR:REVIEW DATE: PATIENT DATA SOURCE: EN,PL//USE INACTIVE PROBLEMS:INACTIVE FLAG: ICD0 Range of Coded ValuesSelect ICD0 LOW CODED VALUE: ICD9 Range of Coded ValuesSelect ICD9 LOW CODED VALUE: 250.00// ICD9 LOW CODED VALUE: 250.00// ICD9 HIGH CODED VALUE: 250.93//Select ICD9 LOW CODED VALUE:
Taxonomy Creation
• After the taxonomy is created
• Re-load the reminder and use SKIP when you reach the taxonomy installation
Renal Disease Taxonomy
REMINDER TAXONOMY entry IHS-END STAGE RENAL DISEASE already EXISTS,
what do you want to do? Select one of the following: C Create a new entry by copying to a new
name I Install or Overwrite the current entry Q Quit the install S Skip, do not install this entry
Install Reminder Term
• REMINDER TERM entry IHS-MICROALBUMIN already EXISTS,
• what do you want to do? • Select one of the following: • C Create a new entry by copying to a ne
name• I Install or Overwrite the current entry• Q Quit the install• S Skip, do not install this entry
Install the Reminder DefinitionREMINDER DEFINITION entry IHS-DIAB MICROALBUMIN 2007
already EXISTS,what do you want to do? Select one of the following: C Create a new entry by copying to a new name I Install or Overwrite the current entry Q Quit the install S Skip, do not install this entry Enter response: S// i Install or Overwrite the current entryAre you sure you want to overwrite? N// Y
Installing the Dialog
• Install the dialog after the reminder is installed
• It may appear that you are installing the reminder again
• Look to the upper left to see where you are
Installing the Dialog
Look here for directions
Select IA again for dialog pieces
Attach to the Reminder
• You are usually asked to attach the dialog to a reminder
• I have named the dialogs and the reminders the same
• If you are not asked during the install, you can manually attach them when you activate the dialog
Install reminder dialog and all components with no further changes:Y// YES
Reminder Dialog IHS-DIAB MICROALBUMIN 2007 is not linked to a reminder.
Select Reminder to Link: IHS-DIAB MICROALBUMIN 2007
Dialog Installation
• An X should be by all the pieces of the dialog
Activate the Dialog
• All dialogs installed through reminder exchange are disabled.
• Exit out of Reminder Exchange and go to the DM (Dialog Management)
Select Reminder Managers Menu Option: DM Reminder Dialog Management
DP Dialog Parameters ... DI Reminder Dialogs
Choose DI (Reminder Dialogs)
Activate the Dialog
• The initial View is of reminders, use CV and Select D to go to dialogs
Activate Dialogs
Activate the Dialog
• Choose the dialog by number then ED
Activate Dialog
NAME: IHS-DIAB MICROALBUMIN 2007 Replace
DISABLE: DISABLED IN EXCHANGE Replace @
SURE YOU WANT TO DELETE? Y (Yes)
CLASS: LOCAL//
SPONSOR:
REVIEW DATE:
SOURCE REMINDER: IHS-DIAB MICROALBUMIN 2007//
Select SEQUENCE: 5//
SEQUENCE: 5//
DIALOG ELEMENT/GROUP: OI MICROALBUMIN//
Select SEQUENCE:
Activate Dialog
Edit the Reminder Term
• The reminder term cannot be populated with lab tests since each site has their own
• The microalbumin used at your site needs to be added to the reminder term.
• Use TE to edit the reminder term
Select Reminder Managers Menu Option: trm Reminder Term Management
TL List Reminder Terms TI Inquire about Reminder
Term TE Reminder Term Edit TC Copy Reminder Term
Edit Reminder Term
Select Reminder Term: IHS-MICROALBUMIN VISN ...OK? Yes// (Yes) NAME: IHS-MICROALBUMIN//CLASS: VISN//REVIEW DATE:DESCRIPTION:The lab tests used at a site to resolve the microalbumin
reminder Edit? NO//Select FINDING ITEM: LT.MICROALBUMIN
Edit Reminder Term Searching for a LABORATORY TEST 1 MICROALBUMIN MICROALBUMIN (retired) 2 MICROALBUMIN 24HR UR 3 MICROALBUMIN DEMO 4 MICROALBUMIN RANDOM MICROALBUMIN RANDOM (retired)CHOOSE 1-4: 3 MICROALBUMIN DEMO Are you adding 'MICROALBUMIN DEMO' as a new FINDINGS (the 1ST for this REMINDER TERM)? No// y (Yes) EFFECTIVE PERIOD: USE INACTIVE PROBLEMS: WITHIN CATEGORY RANK: EFFECTIVE DATE: MH SCALE: CONDITION: CONDITION CASE SENSITIVE: RX TYPE:Select FINDING ITEM:
Finding Items You may enter a new FINDINGS, if you wish Enter one of the following: DR.EntryName to select a DRUG ED.EntryName to select a EDUCATION TOPIC EX.EntryName to select a EXAM HF.EntryName to select a HEALTH FACTOR IM.EntryName to select a IMMUNIZATION LT.EntryName to select a LABORATORY TEST MT.EntryName to select a MEASUREMENT TYPE OI.EntryName to select a ORDERABLE ITEM RP.EntryName to select a RADIOLOGY PROCEDURE CF.EntryName to select a REMINDER COMPUTED FINDING TX.EntryName to select a REMINDER TAXONOMY ST.EntryName to select a SKIN TEST DC.EntryName to select a VA DRUG CLASS DG.EntryName to select a VA GENERIC VM.EntryName to select a VITAL MEASUREMENT
Add to GUI
• CACs need parameter access to edit
• RPMS-EHR configuration menu
• Select Reminders Configuration
• Then select PAR
Set the CFG
Set up GUI
Add to GUI
• Click on the alarm clock
• Select the action drop down menu
Add to GUI
• Choose Edit Cover Sheet Reminder List
Add to GUI
• Select where you are going to add them.
• The choices are in the middle section
• The available reminders are on the bottom left.
• Move them over using the arrows
• Click apply when finished
Add to GUI
TEST,TEST,TEST
• Pick patients where the reminder is not applicable – (non-diabetics)
• Pick patients where the reminder is applicable but not due
• Pick patients where the reminder is applicable and due
• Is it correct??
Testing
• Use reminder maintenance to see what the computer found
• Right click on the reminder and choose clinical maintenance
Check the dialog
• Start a note
• Find the reminder in the reminders drawer
• Double click on the reminder and review the dialog
Check the Dialog
• Is the correct data going into the note?
• Is the order there?• Are you presented
with the dialog to enter the order when you select Finish?
• Is it the correct Quick order?
Check the Dialog
Note
Order
Unable to add items to GUI
• If you consistently get a slash through the alarm clock and are unable to add items to the GUI, follow the following steps
• 1. Use ACT and make sure reminders are active
• 2. Set the NEW REMINDERS PARMETERS TO NO
• 3. Edit the cover sheet Reminder List and set up a very common reminder such as the tobacco screen
• 4. Pick a patient for whom this reminder will be due
• 5. The Slash in the alarm clock should now be gone and you can add your reminders in the GUI
• 6. Go back and reset the NEW REMINDER PARAMETERS to YES