* Nationwide House Energy Rating Scheme (NatHERS) is an initiative of the Australian, state and territory governments.For more details see www.nathers.gov.au
Nationwide House Energy Rating Scheme* Certificate Certificate number: Certificate Date: êStar rating:
MJ/m2
Assessor details
Accreditation number: Name: Organisation:Email: Phone: Declaration of interest:
Key construction and insulation materials (see following pages for details)
Construction:
Insulation:
Glazing:
Plan documents
Plan ref/date: Prepared by:
Net floor area (m2)
Conditioned: Unconditioned: Garage: TOTAL:
Annual thermal performance loads (MJ/m2)
Heating: Cooling: TOTAL:
Dwelling details
Street: Suburb: State:
Type:
Lot/DP number:
Postcode:NCC Class:NatHERSclimate zone:
Ceiling penetrations (see following pages for details)
Sealed: Unsealed: TOTAL:**
**NOTE: This total is themaximum number of ceilingpenetrations allowed to aceiling (under a roof) for thiscertificate. If this number isexceded in construction thenthis certificate IS NOT VALIDand a new certificate is required.Loss of ceiling insulation for thepenetrations listed has beentaken into account with the rating.
Principle downlight type:
Window selection - default windows only
Note on allowable window values:Only a 5% tolerance to the nominatedSHGC window values shown on page 2can be used with this rating.
Note: Only a +/- 5% SHGC tolerance is allowed with this rating.
NB: This tolerance ONLY applies to SHGC, the U-value can always be lower but not higher than the values stated on page 2.
If any of windows selected are outside the 5% tolerance then this certificate is no longer valid and the dwelling will need to be rerated to confirm compliance.
Overview
Scan to access this certificate online and confirm this is valid.
Software:
AAO:
Exposure:
11 Nov 20160000972927-02 4.1
BERS Pro v4.3.0.0 (3.13) cannot be used to model 'roof windows'. Roof windows are 'openable or fixed windows in a roof' and do not have a shaft, as distinctfrom skylights which incorporate a built-in shaft and are not ventilated. BERS Pro v4.3 can only model skylights. If a roof window is present on the floor planthen this certificate is not valid.
4.1100765
Jamie BonnefinCertified [email protected]
1300 443 674
None
BERS Pro v4.3.0.1 (3.13)
ABSA
8692 Abbotsford Road
Homebush
NSW 2140
New Dwelling 1A
56
1/166684 Suburban
190
19Weatherboard Cavity Panel Direct FixCorrugated IronSuspended Timber FloorR2.7 wall insulationR6.0 ceiling insulationR2.5 floor insulation
LED
ALM-002-03 A Aluminium B SG High Solar Gain Low-E
75
60
80
6026
86
92 Abbotsford Road, Homebush
Amrish Maharaj Architect
Page 1 of 4
Window type and performance valueWindow ID Window type U-value SHGCALM-002-03 A ALM-002-03 A Aluminium B SG High Solar Gain Low-E 5.40 0.58ALM-002-01 A ALM-002-01 A Aluminium B SG Clear 6.70 0.70
Window scheduleLocation Window ID Window no. Height (mm) Width (mm) Orientation Outdoor shadeKitchen/Living ALM-002-03 A n/a 2700 4100 E No ShadingKitchen/Living ALM-002-03 A n/a 2700 3800 S Vertical Louvres,
Vertical BladesBathroom ALM-002-01 A n/a 2700 900 S No ShadingStudy ALM-002-01 A n/a 2700 900 S No ShadingBedroom ALM-002-01 A n/a 2700 900 S No ShadingBedroom ALM-002-03 A n/a 2700 4100 W Vertical Louvres,
Vertical Blades
Roof window and skylight type and performance valueID Window type U-value SHGCGEN-04-006a Single-glazed clear, Timber and Aluminium Frame 0.00 0.00
Roof window and skylight scheduleLocation ID Roof
window/skylightno.
Area (m²) Orientation Outdoor shade Indoorshade/diffuser
Bathroom GEN-04-006a 1 0.7 E None No
External wall typeID Wall type Insulation Wall wrap or foilEW-1 Weatherboard Cavity Panel Direct
FixReflective foil with bulk no gap R2.7 Yes
External wall scheduleLocation ID Width (mm) Height (mm) Orientation Fixed Shade Eaves
(mm)Kitchen/Living EW-1 9795 3000 N No 500Kitchen/Living EW-1 5100 3000 E No 2800Kitchen/Living EW-1 7995 3000 S No 1100Bathroom EW-1 1790 3000 S No 1100Study EW-1 2190 3000 S No 1100Bedroom EW-1 6195 3000 N No 500Bedroom EW-1 3995 3000 S No 1100Bedroom EW-1 5100 3000 W No 2900
Internal wall typeWall type Area (m²) Insulation Wall wrap or foilIW-1 - Cavity wall, direct fixplasterboard, single gap
47 No insulation No
* Nationwide House Energy Rating Scheme (NatHERS) is an initiative of the Australian, state and territory governments. For more details see www.nathers.gov.au Page 2 of 4
Nationwide House Energy Rating Scheme* CertificateCertificate number: 0000972927-02 Certificate Date: 11 Nov 2016 ★ Star rating: 4.1
Building features
FloorsLocation Construction Area (m²) Sub floor
ventilationAddedinsulation
Covering
Kitchen/Living Suspended Timber Floor 43.7 Enclosed Bulk Insulationin Contact withFloor R2.5
80/20 Carpet10mm/Ceramic
Bathroom Suspended Timber Floor 5.6 Enclosed Bulk Insulationin Contact withFloor R2.5
Ceramic Tiles8mm
Study Suspended Timber Floor 6.9 Enclosed Bulk Insulationin Contact withFloor R2.5
Carpet 10mm
Bedroom Suspended Timber Floor 24.0 Enclosed Bulk Insulationin Contact withFloor R2.5
Carpet 10mm
Ceiling typeLocation Construction Added
insulationRoof spaceabove
Kitchen/Living Plasterboard Bulk InsulationR6
Yes
Bathroom Plasterboard Bulk InsulationR6
Yes
Study Plasterboard Bulk InsulationR6
Yes
Bedroom Plasterboard Bulk InsulationR6
Yes
Ceiling penetrationsLocation Number Type Diameter (mm) Sealed/unsealedKitchen/Living 9 Downlights - LED 150 SealedKitchen/Living 1 Exhaust Fans 300 SealedBathroom 1 Downlights - LED 150 SealedBathroom 1 Exhaust Fans 300 SealedStudy 2 Downlights - LED 150 SealedBedroom 5 Downlights - LED 150 Sealed
Ceiling fansLocation Number Diameter (mm)None Present
Roof typeConstruction Added
insulationRoof colour
Corrugated Iron Bulk, ReflectiveSide Down, Anti-glare Up R3.3
Dark
Nationwide House Energy Rating Scheme* CertificateCertificate number: 0000972927-02 Certificate Date: 11 Nov 2016 ★ Star rating: 4.1
Building features continued
* Nationwide House Energy Rating Scheme (NatHERS) is an initiative of the Australian, state and territory governments. For more details see www.nathers.gov.au Page 3 of 4
* Nationwide House Energy Rating Scheme (NatHERS) is an initiative of the Australian, state and territory governments.
For more details see www.nathers.gov.au
Certificate Date:
Explanatory notes
Accredited Assessors
To ensure you get a high-quality, professional NatHERS House Energy Rating report, you should always use an
Organisation (AAO).
and continuing professional development requirements to maintain a high and consistent standard of assessments across the country. Non-accredited assessors do not have this level of quality assurance or any on-going training requirements.
concerns, please contact their AAO listed under ‘assessor
Disclaimer
The energy values quoted are for comparison purposes only; they are not a prediction of actual energy use. This rating
the rating.
Contact
For more information on the Nationwide House Energy Rating Scheme (NatHERS), visit www.nathers.gov.au
insulation visit www.yourhome.gov.au
About this report
including heating and cooling, hot water, dishwashers, ovens,
General Information
A NatHERS House Energy Rating is a comprehensive, dynamic computer modelling evaluation of the floorplans, elevations and specifications to predict an energy load of a home. Not all of us use our homes in the same way, so ratings are generated using standard assumptions. This means homes can be compared across the country.
The actual energy consumption of your home may vary significantly from the predicted energy load figures in the report depending on issues such as the size of your household and your personal preferences, e.g. in terms of heating or cooling.
While the figures are an indicative guide to energy use, they can be used as a reliable guide for comparative purposes between different house designs and for demonstrating that the design meets the required regulatory compliance.
Homes that are energy efficient use less energy, are warmer in winter, cooler in summer and cost less to run. The higher the star rating the more energy efficient.
This NatHERS House Energy Rating report was carefully prepared by your assessor on the basis of comprehensive modelling using standard procedures to rate your home using the underlying engine developed by the Australian Commonwealth Scientific and Industrial Research Organisation (CSIRO).
All information relating to energy loads presented in this report is based on a range of standard assumptions in order to allow for comparisons with reports prepared for other homes and to demonstrate minimum regulatory compliance.
The standard assumptions include figures for occupancy, indoor air temperature and are based on a unique climate file for your region.
Additional information
0000972927-02 11 Nov 2016 4.1
Page 4 of 4