Nationwide Tower Inc. Charles County Government La Plata SELF-SUPPORTING 2/7/2003 KDU1036905Z TOWER HEIGHT: JOB NO: INSPECTION DATE: TYPE OF TOWER: SITE NAME: CUSTOMER: . ALL RIGHTS RESERVED. REPRODUCTION OR TRANSLATION OF ANY PART OF THIS INSPECTION REPORT BY ANY MEANS, ELECTRONIC OR MECHANICAL, WITHOUT THE EXPRESSED WRITTEN CONDITION OF NATIONWIDE TOWER COMPANY IS UNLAWFUL AND A VIOLATION OF UNITED STATES COPYRIGHT LAWS. SUBMIT WRITTEN REQUESTS TO: NATIONWIDE TOWER COMPANY, P.O. BOX 1829, HENDERSON, KY 42419 250.00' Since 1987
Transcript

Nationwide Tower Inc.

Charles County GovernmentLa Plata

SELF-SUPPORTING

2/7/2003

KDU1036905Z

TOWER HEIGHT:

JOB NO:

INSPECTION DATE:

TYPE OF TOWER:

SITE NAME:CUSTOMER:

. ALL RIGHTS RESERVED. REPRODUCTION OR TRANSLATION OF ANY PART OF THIS INSPECTION REPORT BY ANY MEANS, ELECTRONIC OR MECHANICAL, WITHOUT THE EXPRESSED WRITTEN CONDITION OF NATIONWIDE TOWER COMPANY IS UNLAWFUL AND A VIOLATION OF UNITED STATES COPYRIGHT LAWS. SUBMIT WRITTENREQUESTS TO: NATIONWIDE TOWER COMPANY, P.O. BOX 1829, HENDERSON, KY 42419

250.00'

Since 1987

NATIONWIDE TOWER INSPECTION REPORTTABLE OF CONTENTS

1. GENERAL SITE CONDITIONS2. ANCHORS3. GUY CABLES AND CONNECTIONS4. TOWER FOUNDATIONS5. TOWER STRUCTURE6. WAVEGUIDE/COAX ICE BRIDGE & ENTRY POINT7. CLIMBING APPARATUS8. GROUNDING9. ANTENNAS10. WAVEGUIDE SUPPORTS11. FAA REQUIRED LIGHTING12. TOWER PAINT/GALVAIZING

Table 1 - EXPLANATION OF BOLT TORQUE CHECKTable 2 - HARDWARE STANDARDS USEDTable 3 - GUY WIRE TENSIONSTable 4 - TOWER PLUMB CHECKTable 5 - DISTANCE FROM TOWER ANCHORS TO TOWER LEG

1122334455678

99

101111

9

DEFINITION OF TERMINIOLOGYDETAIL OF REPAIR WORK

TOWER INSPECTION REPORT

TABLES

JOB NO:

SITE NAME: La Plata

KDU1036905Z INSPECTION DATE:

INSPECTOR Bobby Muller

2/7/2003

iiiiiiWORK REQUIRED WITHIN 3-5 YEARS

RECOMMENDATIONS CONCLUDED iv

Since 1987

DEFINITION OF TERMINOLOGYEXPLANATION OF COLUMN HEADINGS:

SAFETY: ITEM JUDGED TO HAVE A SAFETY DEFICIENCY REQUIRING IMMEDIATE ATTENTION. FAILURE TO REPAIR THIS DEFICIENCY MAY RESULT IN PHYSICAL HARM TO PERSONNEL ON THE TOWER AND GROUND.

EMERGENCY: ITEM JUDGED TO HAVE A DEFICIENCY REQUIRING IMMEDIATE ATTENTION. FAILURE TO REPAIR THIS DEFICIENCY MAY RESULT IN TOWER FAILURE, PROPERTY DAMAGE, OR INJURY TO PERSONNEL ON TOWER AND GROUND.

OFF AIR: ITEM JUDGED TO HAVE A DEFICIENCY REQUIRING IMMEDIATE ATTENTION. FAILURE TO REPAIR THIS DEFICIENCY MAY RESULT IN LOSS OF AIRTIME.

ROUTINE: ITEM JUDGED TO HAVE A DEFICIENCY REQUIRING IMMEDIATE ATTENTION. FAILURE TO REPAIR THIS DEFICIENCY MAY ESCALATE INTO A SAFETY, EMERGENCY, OR OFF AIR CONDITION.

THE CRITERIA USED IN MAKING OUR RECOMMENDATIONS AND OBSERVATIONS ARE BASED ON THE FOUR LEVELS OF PRIORITY:

FIRST: "KEEP THE TOWER STANDING". THESE ARE STRUCTURAL INTEGRITY ITEMS THAT AFFECT THE STABILITY OF THE TOWER.

SECOND: "AVOID OFF AIR AND/OR DOWN TIME". THESE ARE SYSTEM INTEGRITY ITEMS, WHICH CAN AFFECT THE SIGNAL OR ABILITY TO REMAIN ON AIR.

THIRD: "AVOID LIABILITY RISK". THESE ARE LIABILITY ITEMS SUCH AS HAZARDS TO CLIMBERS OR PERSONS AT OR AROUND THE STRUCTURE, INCLUDING "ATTRACTIVE NUISANCE" POTENTIALS.

FOURTH: "KEEP THE COST OF OWNERSHIP AS LOW AS PRACTICAL". THROUGH CAREFUL MAINTENANCE AND PREVENTATIVE MAINTENANCE, THE UTILITY VALUE OF THE STRUCTURE CAN BE MAXIMIZED AND THE COST KEPT LOW.

La Plata

KDU1036905Z

Bobby Muller

2/7/2003

i

JOB NO:SITE NAME: INSPECTOR

INSPECTION DATE:Since 1987

EMERGENCY REPAIR WORKTo view Code Standards & Regulations see http://www.nationwidetower.com/codes/index.html

SITE NAME INSPECTORLa PlataJOB NO: INSPECTION DATE:KDU1036905Z 2/7/2003

Bobby Muller

Since 1987

5D BENT/RUSTY/DAMAGED DIAGONAL(S). THIS SIGNIFICANTLY REDUCES THE STRENGTH OF THE TOWER. WE RECOMMEND REPAIRING AND/OR REPLACING DIAGONAL(S) IN ACCORDANCE WITH TIA/EIA 222 F STANDARD, SECTION 3.1.10.Elevation: 150

11A LIGHTING SYSTEM IS OUT DATED. WE RECOMMEND UPDATING THE LIGHTING SYSTEM TO BRING THE TOWER IN COMPLIANCE WITH FCC/FAA.Elevation: 150

11G LIGHTING CONDUIT BROKEN. THIS IS ALLOWING WATER TO ENTER THE LIGHTING SYSTEM. WE RECOMMEND REPLACING THE CONDUIT IN ACCORDANCE WITH FAA.

11G LIGHTING CONDUIT MISSING BREATHERS. WE RECOMMEND FURNISHING AND INSTALLING BREATHERS IN ACCORDANCE WITH FAA.

11N THERE IS NO SITE MONITORING SYSTEM ON TOWER. WE RECOMMEND TO FURNISH AND INSTALL A SITE MONITORING DEVICE TO MONITOR LIGHTS, HVAC, ACCESS, ETC. VISIT OUR WEBSITE AT HTTP://WWW.LIGHTMONITORING.COM

12A FADED PAINT ON TOWER (I.E., PEELING, CHIPPING, ETC.) THE PAINT DOES NOT MEET FEDERAL COLOR STANDARD #595. THE TOWER SHOULD BE CLEANED AND PAINTED IN ACCORDANCE WITH FAA DAYMARKING STANDARDS. NOTE: TOWERS ARE NORMALLY PAINTED WITH ENAMEL WITH A USEFUL LIFE EXPECTANCY OF THREE (3) TO FIVE (5) YEARS. AS AN ALTERNATE, YOU MAY WISH TO CONSIDER A POLYURETHANE COATING THAT PROVIDES FIFTEEN (15) TO TWENTY (20) YEARS LIFE EXPECTANCY.Elevation: 0

12C PAINT NOT VISUALLY EFFECTIVE AS WARNING TO AIRCRAFT. WE RECOMMEND PAINTING THE TOWER IN ACCORDANCE WITH FAA A/C 70/7460-IJ

12D FEEDLINES LOCATED ON OUTSIDE OF TOWER NOT PAINTED. WE RECOMMEND PAINTING THE LINES IN ACCORDANCE WITH FAA A/C 70/7460-1J, CHAPTER 3, PARAGRAPH 33.

SAFETY REPAIR WORKTo view Code Standards & Regulations see http://www.nationwidetower.com/codes/index.html

1I TOWER SITE DOES NOT HAVE RF RADIATION WARNING AND/OR HIGH VOLTAGE BROADCAST EQUIPMENT SIGNS POSTED IN ACCORDANCE WITH FCC SECTION 1 PARAGRAPH 1.1310 AND/OR OSHA 47 CFR 1.1307(B). WE RECOMMEND FURNISHING AND INSTALLING SIGNS.

6A FEEDLINES DO NOT HAVE A WAVEGUIDE/ICE BRIDGE. THE BRIDGE SERVES TO SUPPORT AND PROTECT THE FEEDLINES. WE RECOMMEND FURNISHING AND INSTALLING A WAVEGUIDE/ICE BRIDGE FROM THE TOWER TO THE BUILDING IN ACCORDANCE WITH EIA/TIA 222 F STANDARDS.

7A TOWER NOT EQUIPPED WITH A SAFETY- CLIMB DEVICE. THIS IS AN OSHA VIOLATION. SAFETY CLIMBS ARE REQUIRED IN ACCORDANCE WITH OSHA 29 CFR 1910.27 ON ALL LADDERS OVER 6' IN UNBROKEN LENGTH. WE RECOMMEND INSTALLING AN OSHA APPROVED SAFETY CLIMB.

7E RUSTY CLIMBING HARDWARE. WE RECOMMEND WIRE BRUSHING/COLD GALVANIZING HARDWARE IN ACCORDANCE WITH SSPC-SP2 AND AGA STANDARDS.Elevation: 0

7G RUNGS OF CLIMBING LADDER NOT SKID RESISTANT. WE RECOMMEND THAT A PROTECTIVE MATERIAL BE APPLIED TO THE RUNGS IN ACCORDANCE WITH OSHA 29 CFR 1926.1053, PARAGRAPH (6)(I).

7I WORK PLATFORMS ARE NOT COMPLIANT WITH OSHA. WE RECOMMEND FURNISHING AND INSTALLING OSHA APPROVED HAND RAILS AND/OR TOE BOARDS IN ACCORDANCE WITH OSHA 29 CFR 1926.1053, PARAGRAPH (6)(1).

11G LIGHTING CONDUIT IMPROPERLY SECURED. WE RECOMMEND PROPERLY SECURING THE CONDUIT IN ACCORDANCE WITH FAA.

SITE NAME INSPECTORLa PlataJOB NO: INSPECTION DATE:KDU1036905Z 2/7/2003

Bobby Muller

Since 1987

OFF AIR REPAIR WORKTo view Code Standards & Regulations see http://www.nationwidetower.com/codes/index.html

6B LINE HANGERS NOT INSTALLED CORRECTLY. WE RECOMMEND REPLACING AND/OR REINSTALLING AS NECESSARY IN ACCORDANCE WITH TIA/EIA 222 F STANDARD.Elevation: 20

6B LINE HANGERS ARE MISSING. WE RECOMMEND INSTALLING LINE HANGERS IN ACCORDANCE WITH TIA/EIA 222 F STANDARD.Elevation: 20

6C PORT HOLE COVERS ARE DAMAGED AND/OR MISSING. WE RECOMMEND REPLACING DAMAGED OR MISSING ENTRY PORT HOLE COVERS IN ACCORDANCE WITH TIA/EIA 222 F STANDARDS.

8E WAVEGUIDE/COAX NOT PROPERLY GROUNDED AT TOP AND BOTTOM OF RUN. WE RECOMMEND FURNISHING AND INSTALLING GROUNDING PER OSHA 29 CFR 1910.308 AND TIA/EIA 222 F STANDARD, SECTION 12.1.3.

8F MISSING BUS BARS. WE RECOMMEND FURNISHING AND INSTALLING BUS BARS IN ACCORDANCE WITH OSHA 29 CFR 1910.308 AND TIA/EIA 222 F STANDARD, SECTION 12.1.3.

8G FEEDLINES NOT GROUNDED AT ENTRY PORT. WE RECOMMEND FURNISHING AND INSTALLING GROUNDING PER OSHA 29 CFR 1910.308 AND TIA/EIA 222 F STANDARD, SECTION 12.1.3.

8G FEEDLINES AT ENTRY PORT NOT GROUNDED TO BUS BAR. WE RECOMMEND FURNISHING AND INSTALLING A BUS (GROUND) BAR IN ACCORDANCE WITH OSHA 29 CFR 1910.308 AND TIA/EIA 222 F STANDARD, SECTION 12.1.3.

8H GROUND WIRES ARE NOT ROUTED IN DOWNWARD DIRECTION. WE RECOMMEND PROPERLY REINSTALLING GROUNDING IN ACCORDANCE WITH OSHA 29 CFR 1910.308 AND TIA/EIA 222 F STANDARD, SECTION 12.1.3.

8I HOISTING GRIP INSTALLED ABOVE UPPER GROUND KIT. WE RECOMMEND RELOCATING THE HOISTING GRIP BELOW THE GROUND KIT IN ACCORDANCE WITH OSHA 29 CFR 1910.308 AND TIA/EIA 222 F STANDARD, SECTION 12.1.3.

8J TOWER MISSING LIGHTNING ROD. WE RECOMMEND FURNISHING AND INSTALLING A LIGHTNING ROD AND DOWN CONDUCTOR IN ACCORDANCE WITH OSHA 29 CFR 1910.308 AND TIA/EIA 222 F STANDARD, SECTION 12.1.1.

8K PERIMETER FENCE NOT GROUNDED. WE RECOMMEND FURNISHING AND INSTALLING GROUNDING IN ACCORDANCE WITH OSHA 29 CFR 1910.308 AND TIA/EIA 222 F STANDARD, SECTION 12.1.3.

9B RUSTY ANTENNA MOUNTING HARDWARE. RUST CAN CAUSE ANTENNA MOUNTS TO DETERIORATE. MORE IMPORTANTLY, RUST FROM THE ANTENNA MOUNTS WILL BLEED ONTO THE TOWER CAUSING THE OXIDATION PROCESS TO BEGIN ON ANY UNCOATED TOWER STEEL. WE RECOMMEND WIRE BRUSHING AND COLD GALVANIZING THE ANTENNA MOUNTS IN ACCORDANCE WITH SSPC-SP 2 AND AGA STANDARDS.Elevation: 0

10B EXCESSIVE BEND AND/OR TWIST IN LINE TO FEED CONNECTION. WE RECOMMEND REPLACING THE LINE IN ACCORDANCE WITH TIA/EIA 222 F STANDARDS.Elevation: 0

10C FEEDLINES DO NOT RUN STRAIGHT. WE RECOMMEND FURNISHING AND INSTALLING A WAVEGUIDE LADDER OR PROPERLY SECURING THE LINES AT APPROPRIATE INTERVALS IN ACCORDANCE WITH TIA/EIA 222 F STANDARDS.Elevation: 0

SITE NAME INSPECTORLa PlataJOB NO: INSPECTION DATEKDU1036905Z 2/7/2003

Bobby Muller

Since 1987

10D FEEDLINES NOT PROPERLY SECURED. WE RECOMMEND PROPERLY SECURING THE LINES BY INSTALLING WRAP LOCK EVERY AT 3 TO 4 FT INTERVAL IN ACCORDANCE WITH TIA/EIA 222 F STANDARDS.Elevation: 0

10E CHAFING FEEDLINE. WE RECOMMEND WEATHER PROOFING AND PROPERLY SECURING THE LINE IN ACCORDANCE WITH TIA/EIA 222 F STANDARDS.Elevation: 0

10F FEEDLINES NOT PROPERLY SUPPORTED WITH HOISTING GRIPS. WE RECOMMEND FURNISHING AND INSTALLING HOISTING GRIPS AS NECESSARY IN ACCORDANCE WITH TIA/EIA 222 F STANDARDS.Elevation: 0

ROUTINE REPAIR WORKTo view Code Standards & Regulations see http://www.nationwidetower.com/codes/index.html

9G TOWER HAS UNUSED LINES/ANTENNAS AND/OR EQUIPMENT. WE RECOMMEND TO REMOVE ALL UNUSED EQUIPMENT FROM THE TOWER TO DECREASE WINDLOAD IN ACCORDANCE WITH EIA/TIA 222 F STANDARDS.

11G RUSTY LIGHTING CONDUIT FITTINGS. WE RECOMMEND THAT THE FITTINGS BE WIRE BRUSHED AND COLD GALVANIZED IN ACCORDANCE WITH FAA.

11G RUSTY LIGHTING CONDUIT. WE RECOMMEND CLEANING AND PAINTING CONDUIT IN ACCORDANCE WITH FAA.

JOB NO:SITE NAME

KDU1036905ZLa Plata INSPECTOR

INSPECTION DATE: 2/7/2003Bobby Muller

Since 1987

Since 1987

SITE NAMEKDU1036905ZLa Plata INSPECTOR

INSPECTION DATE:2/7/2003Bobby Muller

JOB NO:

RE-LAMP TOWER (IF APPLICABLE).RETENTION SAFETY CLIMB DEVICE (IF APPLICABLE).

CLEAN AND PAINT.

CHECK TO SEE IF BOLTS ARE OF PROPER TORQUE VALUE.PERFORM AN ANNUAL INSPECTION REPORT.

WORK REQUIRED WITHIN 3 TO 5 YEARS

iii

Since 1987

JOB NO:Bobby Muller2/7/2003INSPECTION DATE:

INSPECTORLa PlataKDU1036905Z

SITE NAME

RECOMMENDATIONS CONCLUDED

WE ALSO RECOMMEND OUR ANNUAL MAINTENANCE AGREEMENT TO ENSURE THE TOWER IS MAINTAINED ON A YEARLY BASIS. A SAMPLE MAINTENANCE AGREEMENT IS ENCLOSED. THIS REPORT AND COMMENTS REFLECT THE GENERAL CONDITION OF THE TOWER ON THE DATE OF INSPECTION.

RECOMMENDATIONS LISTED ON THE PRECEDING PAGES MAY BE INCORPORATED INTO A 3-5 YEAR PROGRAM. IF SO, THE PRICE DOES NOT INCLUDE THE ADDITIONAL REPAIR OF LATENT DEFECTS IF FOUND DURING THIS WORK. IF LATENT DEFECTS ARE FOUND, NWT WILL SUBMIT A LUMP-SUM BID TO THE OWNER TO PERFORM THE NECESSARY ADDITIONAL REPAIRS. UNDER NO CIRCUMSTANCES WILL THE ADDITIONAL REPAIR WORK BE DONE WITHOUT OWNER'S WRITTEN AUTHORIZATION IN THE FORM OF A SEPERATE REPAIR CONTRACT AGREED TO BY BOTH PARTIES. OWNER AGREES TO UDERTAKE ALL MEASURES NECESSARY TO EXPEDITE DECISIONS REGARDING REPAIRS AND AVOID DELAYING THE WORK OUTLINED UNDER THE TERMS OF THE CONTRACT. WE RECOMMEND $5,000 BE SET ASIDE FOR LATENT DEFECTS.

HANDLING, REMOVING, AND/OR DISPOSAL OF HAZARDOUS OR CONTAMINATED MATERIAL(ASBESTOS, LEAD, OR ANY SUBSTANCE REQUIRING SPECIAL HANDLING) ARE NOT INCLUDED IN ANY PRICE SUBMITTED OR WORK HEREIN.

iv

STATED HEIGHTS ARE APPROXIMATE FOR PURPOSES OF REPAIR ONLY. THESE STATED VALUES MAY NOT CORRESPOND EXACTLY TO OFFICIAL FAA/FCC FILINGS.

Tower Inspection ReportKDU1036905ZCharles County GovernmentLa Plata

SELF-SUPPORTING

Other

2/7/2003Bobby Muller

25 F38-55-5476-95-11

JOB NO:CUSTOMER:SITE NAME:

TOWER TYPE:HEIGHT:MANUFACTURER:

INSPECTION DATE:INSPECTOR:

WIND:TEMPERATURE:LATITUDE:LONGITUDE:

Since 1987

250.00'

STATE: MDWEATHER: SNOW

BREEZY

1. GENERAL SITE CONDITIONSA. IS TOWER RELIABLE FOR COMPLETE SURVEY?

B. ACCESS ROAD IN GOOD CONDITION?

C. TOWER AND BUILDING AREA ARE SECURE (ADEQUATE FENCE, BARBED WIRE, GATES, LOCKS) ?

D. SITE IS DRAINING PROPERLY?

E. EQUIPMENT SHELTER AND CIVILWORK IN GOOD CONDITION?

F. CONDITION OF EQUIPMENT ON SITE IN GOOD CONDITION (GENERATOR, FUEL TANK)?

G. FENCE, TOWER, GUY ANCHORS, ENTRY PORT, WAVEGUIDE/ICE BRIDGE CLEAR OF VINES AND/OR VEGETATION GROWING ON THEM AND NO WEEDS GROWING INSIDE OF FENCE?

H. TOWER OR GUY CABLES CLEAR OF LARGE TREES WITHIN FALLING DISTANCE?

I. RF RADIATION WARNING SIGNS, FCC SIGNS, AND/OR DANGEROUS HIGH VOLTAGE EQUIPMENT SIGNS POSTED IN ACCORDANCE WITH FCC REQUIREMENTS?

IF YOU WOULD LIKE TO SPEAK WITH THE DIRECTOR OF INSPECTION CONCERNING THIS

REPORT, CALL NATIONWIDE TOWERCOMPANY AT PH. (270) 869-8000. ADDITIONAL COPIES OF THIS REPORT ARE AVAILABLE. 1

©2002. NATIONWIDE TOWER COMPANY.

Since 1987

SITE NAME: Bobby MullerINSPECTOR:La PlataJOB NO: INSPECTION DATE:KDU1036905Z 2/7/2003

J. TOWER FREE OF EXCESSIVE BIRD ROOSTING?

2. ANCHORS

A. GUY ANCHORS PROTECTED FROM VEHICLE, FARM MACHINERY, AND CATTLE DAMAGE?

B. ANCHOR LOCATIONS ARE READILY ACCESSIBLE TO MAINTENANCE CREW?

C. ANCHOR HEADS ARE ABOVE GRADE AND FREE OF TWIST?

D. ANCHOR HEADS/RODS/SHAFTS ARE FREE OF RUST, CORROSION, AND DAMAGE?

E. ANCHORS LINE UP PROPERLY WITH TOWER LEGS?

F. ANCHOR BOLTS ARE FREE OF RUST AND OF PROPER TORQUE VALUE?

G. CATHODIC PROTECTION HAS BEEN INSTALLED ON ANCHORS?

H. ANCHORS FREE OF CRACKING, SPALLING OR EVIDENCE OF MOVEMENT?

I. PROPER DRAINAGE AND ANCHORS FREE FROM EROSION?

A. TURNBUCKLES FREE OF RUST, CORROSION, AND DEFORMITIES?

B. TURNBUCKLES ARE OF PROPER SIZE AND ADJUSTABLE IN EITHER DIRECTION?

C. TURNBUCKLES DISTRIBUTED EVENLY ON FAN PLATE?

3. GUY CABLES AND CONNECTIONS

IF YOU WOULD LIKE TO SPEAK WITH THE DIRECTOR OF INSPECTION CONCERNING THIS

REPORT, CALL NATIONWIDE TOWERCOMPANY AT PH. (270) 869-8000. ADDITIONAL COPIES OF THIS REPORT ARE AVAILABLE. 2

©2002. NATIONWIDE TOWER COMPANY.

Since 1987

SITE NAME: Bobby MullerINSPECTOR:La PlataJOB NO: INSPECTION DATE:KDU1036905Z 2/7/2003

D. TURNBUCKLE SAFETY CABLES ADEQUATELY SIZED AND PROPERLY INSTALLED IN A FIGURE 8 FORMATION?

E. COTTER PINS IN PLACE, SECURE, AND FREE OF

F. GUY THIMBLES OF PROPER SIZE, INSTALLED CORRECTLY, FREE OF RUST, AND CORROSION?

G. CABLES CLAMPS INSTALLED CORRECTLY, EVENLY SPACED, AND PROPERLY TORQUED AND FREE OF RUST AND CORROSION?

H. CABLE ENDS PROPERLY PROJECT FROM PERFORMED DEAD END GRIPS?

I. DEAD ENDS OF CABLES ARE OF PROPER LENGTH AND SECURED TO PREVENT UNRAVELING?

J. GUY CABLES FREE FROM SPLICES, STRANDS, FRACTURES, OR RUST?

K. GUY CABLES FREE FROM KINKS OR DEFORMITIES?

L. U-BOLT(S) ARE INSTALLED CORRECTLY ON DEAD SIDE OF CABLE, EVENLY SPACED, PROPERLY TORQUED, AND FREE OF RUST AND CORROSION?

M. PREFORM GUY GRIPS AT ANCHOR PULL OFFS HAVE SAFETY END SLEEVES ARE ADEQUATELY INSTALLED AND FREE OF RUST?

N. GUY INSULATORS APPEAR TO BE IN GOOD CONDITION?

O. GUY WIRES PROPERLY TENSIONED?

P. ARE GUY WIRES AT PULL OFFS ATTACHED WITH PROPER HARDWARE?

Q. DOES TOWER HAVE PROPER PULL-OFF POINTS?

R. DO GUY WIRES HAVE A PROTECTIVE COATING?

IF YOU WOULD LIKE TO SPEAK WITH THE DIRECTOR OF INSPECTION CONCERNING THIS

REPORT, CALL NATIONWIDE TOWERCOMPANY AT PH. (270) 869-8000. ADDITIONAL COPIES OF THIS REPORT ARE AVAILABLE. 3

©2002. NATIONWIDE TOWER COMPANY.

Since 1987

SITE NAME: Bobby MullerINSPECTOR:La PlataJOB NO: INSPECTION DATE:KDU1036905Z 2/7/2003

4. TOWER FOUNDATIONS

A. CONCRETE FOUNDATION ABOVE GRADE, IN GOOD CONDITION, NO CRACKING/SPALLING AND PROPERLY SEALED?

B. GROUTING UNDER TOWER LEGS PROPERLY INSTALLED?

5. TOWER STRUCTUREA. TOWER LEGS CORRECTLY IN LINE WITH TOWER CENTER AND APPROPRIATE ANCHORS?

B. VISUAL CHECK INDICATES TOWER IS PLUMB AND FREE OF TWIST?

C. ALL STRUCTURAL MEMBERS INSTALLED CORRECTLY WITH NO MISSING MEMBERS?

D. MEMBERS AND ATTACHMENTS ARE IN GOOD CONDITION (NO BENT, BROKEN, OR OTHERWISE DAMAGED MEMBERS OR ATTACHMENTS)?

E. STRUCTURAL BOLTS INSTALLED CORRECTLY WITH PROPER TORQUE AND LOCKING DEVICES?

F. WELDS CONFORM TO STANDARDS?

G. FLANGE PLATES FREE OF GAP AND ACHIEVING 50% LOAD BEARING?

H. WEEP HOLES ARE UNOBSTRUCTED?

I. ARE TOWER LEGS CAPPED?

IF YOU WOULD LIKE TO SPEAK WITH THE DIRECTOR OF INSPECTION CONCERNING THIS

REPORT, CALL NATIONWIDE TOWERCOMPANY AT PH. (270) 869-8000. ADDITIONAL COPIES OF THIS REPORT ARE AVAILABLE. 4

©2002. NATIONWIDE TOWER COMPANY.

Since 1987

SITE NAME: Bobby MullerINSPECTOR:La PlataJOB NO: INSPECTION DATE:KDU1036905Z 2/7/2003

6. WAVEGUIDE/COAX ICE BRIDGE & ENTRY POINT

A. WAVEGUIDE/ICE BRIDGE PROVIDES ADEQUATE LINE PROTECTION?

B. LINE HANGERS ARE INSTALLED CORRECTLY, SECURELY, AND EVENLY SPACED?

C. ENTRY PORT HOLE COVERS IN GOOD CONDITION?

D. LINES PROPERLY INSTALLED AND SEALED WITH BOOT HARDWARE?

7. CLIMBING APPARATUS

A. TOWER HAS OSHA-APPROVED SAFETY CLIMB DEVICE INSTALLED?

B. SAFETY CLIMB DEVICE PROPERLY INSTALLED, FREE OF RUST, AND IN GOOD WORKING CONDITION?

C. ALL LADDER SPLICES COMPLETE AND SECTIONS FIRMLY ATTACHED TO TOWER?

D. CLIMBING PEGS, IF USED, APPROPRIATE NUMBER INSTALLED, FREE OF RUST, AND OF PROPER TORQUE VALUE?

E. ALL CLIMBING HARDWARE IS PROPERLY INSTALLED AND RUST FREE?

F. ALL LADDER RUNGS OR CLIMBING PEGS ARE PRESENT AND IN GOOD CONDITION?

G. SKID RESISTANT MATERIAL HAS BEEN APPLIED TO ALL (LADDER, RUNGS, CLIMBING PEGS, AND WORK PLATFORMS) IN ACCORDANCE WITH OSHA?

H. TOWER IS PROTECTED BY AN ANTI-CLIMB DEVICE?

IF YOU WOULD LIKE TO SPEAK WITH THE DIRECTOR OF INSPECTION CONCERNING THIS

REPORT, CALL NATIONWIDE TOWERCOMPANY AT PH. (270) 869-8000. ADDITIONAL COPIES OF THIS REPORT ARE AVAILABLE. 5

©2002. NATIONWIDE TOWER COMPANY.

Since 1987

SITE NAME: Bobby MullerINSPECTOR:La PlataJOB NO: INSPECTION DATE:KDU1036905Z 2/7/2003

I. DO WORK PLATFORMS HAVE OSHA APPROVED HAND RAILS AND TOE BOARDS?

8. GROUNDINGA. INDIVIDUAL GUY CABLES ARE PROPERLY GROUNDED?

B. ANCHOR HEAD PLATES OR SHAFTS ARE GROUNDED?

C. TOWER BASE IS PROPERLY GROUNDED?

D. WAVEGUIDE/ICE BRIDGE IS PROPERLY GROUNDED?

E. WAVEGUIDE/COAX PROPERLY GROUNDED TO BUS BAR, DOWN CONDUCTOR AND AT EVERY 200 FT?

F. ARE BUS BARS INSTALLED CORRECTLY?

G. WAVEGUIDE/ COAX PROPERLY GROUNDED AT BUILDING PORT ENTRY?H. GROUND WIRES ROUTED IN DOWNWARD DIRECTION WITH NO SHARP BENDS?

I. HOISTING GRIP INSTALLED BELOW UPPER GROUND

J. TOWER HAS PROPER LIGHTNING PROTECTION, DOWN CONDUCTOR, AND IS PROPERLY INSTALLED?

K. FENCE IS PROPERLY GROUNDED?

9. ANTENNAS

A. ANTENNAS OR ANTENNA COMPONENTS ARE IN GOOD CONDITION?

B. HARDWARE IS PRESENT AND FREE FROM RUST?

IF YOU WOULD LIKE TO SPEAK WITH THE DIRECTOR OF INSPECTION CONCERNING THIS

REPORT, CALL NATIONWIDE TOWERCOMPANY AT PH. (270) 869-8000. ADDITIONAL COPIES OF THIS REPORT ARE AVAILABLE. 6

©2002. NATIONWIDE TOWER COMPANY.

Since 1987

SITE NAME: Bobby MullerINSPECTOR:La PlataJOB NO: INSPECTION DATE:KDU1036905Z 2/7/2003

C. ALL STIFF-ARM TIEBACKS PROPERLY CONNECTED TO ANTENNA AND TOWER?

D. ALL APPROPRIATE FEEDHORN GUY SPRING HANGERS PROPERLY IN PLACE?

E. RADOME COVERS ARE PRESENT AND FREE FROM ANY CRACK OR TEARS?

F. ANTENNA MOUNT STRUCTURAL MEMBERS APPEAR ADEQUATE & SECURE?

G. ALL TOWER LINES AND ANTENNA(S)/EQUIPMENT ARE IN USE?

10. WAVEGUIDE SUPPORTSA. LINE TO FEED CONNECTION SECURE WITH NO EXCESSIVE MOVEMENT ALLOWED?

B. LINE TO FEED CONNECTION IS FREE FROM EXCESSIVE BENDS OR TWISTS?

C. ALL LINE RUNS STRAIGHT WITH DRIP LOOPS, END CONNECTIONS, WEATHERPROOFED, AND IN GOOD CONDITION?

D. ALL WAVEGUIDE/COAX RUNS SUPPORTED AT PROPER INTERVALS?

E. LINE PROTECTIVE COATING IF "TIED" TO TOWER MEMBERS IS FREE FROM CHAFING?

F. ALL LINES PROPERLY SUPPORTED AT TOP WITH HOISTING GRIPS THAT ARE IN GOOD CONDITION AND PROPERLY ATTACHED?

G. FEEDLINE IS FREE FROM ANY VISIBLE AIR LEAKS?

11. FAA REQUIRED LIGHTINGIF YOU WOULD LIKE TO SPEAK WITH THE DIRECTOR OF INSPECTION CONCERNING THIS

REPORT, CALL NATIONWIDE TOWERCOMPANY AT PH. (270) 869-8000. ADDITIONAL COPIES OF THIS REPORT ARE AVAILABLE. 7

©2002. NATIONWIDE TOWER COMPANY.

Since 1987

SITE NAME: Bobby MullerINSPECTOR:La PlataJOB NO: INSPECTION DATE:KDU1036905Z 2/7/2003

A. IS LIGHTING SYSTEM UPDATED AND IN COMPLIANCE WITH CURRENT FAA/FCC STANDARDS?

B. BEACON, OBSTRUCTION LIGHT, AND STROBE UNIT GLASS ARE FREE FROM ANY CRACKS OR BREAKS?

C. ARE LAMP UNITS CLEAN WITH WIRES, TERMINALS, & SOCKETS CORROSION FREE?

D. LAMP UNIT CLOSURE BOLTS OR SPRING FASTENERS FUNCTIONING PROPERLY AND FREE OF RUST?

E. BEACON OR STROBE UNIT CORD IN GOOD CONDITION AND WITH UNIT CORD DRIP LOOP NOT RUBBING ON TOWER MEMBERS?

F. OBSTRUCTION LIGHTS CORRECTLY POSITIONED AND PROPERLY SECURED TO TOWER?

G. CONDUIT SUPPORTED AT MAX. 8 FT. INTERVALS AND ALL JOINTS TIGHT, FREE OF RUST AND BREATHERS CLEAR AND CLEAN?

H. WIRE CORRECTLY INSTALLED OVER WIRE SUPPORTS IN JUNCTION BOXES AND TERMINAL BLOCKS TIGHT AND FREE OF CORROSION?

I. JUNCTION BOX TERMINALS TIGHT AND FREE OF CORROSION?

J. PHOTOCELL POSITIONED SO THAT IT HAS UNOBSTRUCTED VIEW OF THE NORTH SKY?

K. ALL LIGHTS FUNCTIONAL?

L. LAMPS/FLASHTUBES REPLACED?

M. TYPE OF LIGHTING SYSTEM?

IF YOU WOULD LIKE TO SPEAK WITH THE DIRECTOR OF INSPECTION CONCERNING THIS

REPORT, CALL NATIONWIDE TOWERCOMPANY AT PH. (270) 869-8000. ADDITIONAL COPIES OF THIS REPORT ARE AVAILABLE. 8

©2002. NATIONWIDE TOWER COMPANY.

Since 1987

SITE NAME: Bobby MullerINSPECTOR:La PlataJOB NO: INSPECTION DATE:KDU1036905Z 2/7/2003

N. IS A FAA APPROVED LIGHT MONITORING DEVICE MOUNTED ON THE TOWER AND IN GOOD WORKING CONDITION?

O. DOES CURRENT LIGHT SYSTEM HAVE A FAA APPROVED ALARM CONTROLLER?

12. TOWER PAINT/GALVANIZING

A. TOWER PAINT/GALVANIZING IS FREE FROM FADING, CHIPPING, PEELING, OR GENERAL FAILURE?

B. IF REQUIRED, PROPER FAA APPROVED COLORS AND BANDING?

C. PAINT VISUALLY EFFECTIVE AS WARNING TO AIRCRAFT?

D. FEED LINES PROPERLY BANDED?

E. IS TOWER CURRENTLY TOP COATED WITH POLYURETHANE?

IF YOU WOULD LIKE TO SPEAK WITH THE DIRECTOR OF INSPECTION CONCERNING THIS

REPORT, CALL NATIONWIDE TOWERCOMPANY AT PH. (270) 869-8000. ADDITIONAL COPIES OF THIS REPORT ARE AVAILABLE. 9

©2002. NATIONWIDE TOWER COMPANY.

Since 1987

SITE NAME: Bobby MullerINSPECTOR:La PlataJOB NO: INSPECTION DATE:KDU1036905Z 2/7/2003

Min. Torque (Ft-Lbs):

EXPLANATION OF BOLT TORQUE CHECK STRUCTURAL BOLT CONNECTIONS ARE "SAMPLED" AT THE RATE OF AT LEAST 10 BOLTS PER EACH 20 VERTICAL FEET OF TOWER HEIGHT. THE TOWER IS CONSIDERED TO BE IN ACCEPTABLE CONDITION IF THE NUMBER OF UNDER-TORQUED BOLTS IS FOUND TO BE NO MORE THAN 5% OF THE TOTAL SAMPLED.

THE TOWER IS SAID TO HAVE A "MAINTENANCE DEFICIENCY" IF THE NUMBER OF UNDER-TORQUED BOLTS IS 6% TO 30% OF THE TOTAL SAMPLED. IF THIS IS THE CASE, THE TOWER SHOULD BE RE-CHECKED, AT LEAST ANNUALLY. SINCE EACH UNDER-TORQUED BOLT FOUND DURING THE RANDOM SAMPLING PROCESS IS RE-TIGHTENED TO THE PROPER LEVEL, THE NUMBER OF UNDER-TORQUED BOLTS WILL EVENTUALLY DROP BACK BELOW THE STRUCTURALLY UNACCEPTABLE CONDITION AND ALL BOLTS SHOULD BE CHECKED AND RE-TIGHTENED TO CORRECT LEVELS.

THE CONTROLLING BOLT TORQUE VALUES USED ARE:

Bolt Diameter:3/8"1/2"5/8"3/4":

204590125

Nominal Guy Cable Diameter

Minimum Turnbuckle Size

Thimble Size w/Fist Grips or Crosby

Thimble Size w/Preformed Dead End

3/8 EHS 5/8 x 12 1/2 1/27/16 EHS 3/4 x 12 9/16 9/161/2 EHS

9/16 EHS5/8 EHS

3/4 EHS & BS7/8 BS

7/8 x 127/8 x 121 x 12

1 - 1/4 x 181 - 1/2 x 18

5/85/83/47/81

5/85/83/47/81

HARDWARE STANDARDS USED:

IF YOU WOULD LIKE TO SPEAK WITH THE DIRECTOR OF INSPECTION CONCERNING THIS

REPORT, CALL NATIONWIDE TOWERCOMPANY AT PH. (270) 869-8000. ADDITIONAL COPIES OF THIS REPORT ARE AVAILABLE. 10

©2002. NATIONWIDE TOWER COMPANY.

Since 1987

SITE NAME: Bobby MullerINSPECTOR:La PlataJOB NO: INSPECTION DATE:KDU1036905Z 2/7/2003

Antenna Survey

AzimuthElevationMountCoax TypeMake And Modeldirectionaldierctionaldirectionaltrombonetrombonecamera

trombonetrombonediapoleomni

diapolediapolelightsomni

diapoleomni

diapoledirectional

diapoleomni

diapolediapoleomniomni

diapole

1/2" HELAX1/2" HELAX1/2" HELAX7/8" HELAX7/8" HELAX1/4" HELAX7/8" HELAX7/8" HELAX7/8" HELAX7/8" HELAX7/8" HELAX7/8" HELAX

Other7/8" HELAX7/8" HELAX7/8" HELAX7/8" HELAX7/8" HELAX7/8" HELAX

Other7/8" HELAX7/8" HELAX7/8" HELAX7/8" HELAX7/8" HELAX

PipePipePipeLegLeg

PlatformLegLegPipePipePipePipePipePipePipePipePipePipePipePipePipePipePipePipePipe

7881

110115133154173190250250250250250250250250250250250

250250250250250250

7878

322108108322108108

000000000

909090

180180180180180

IF YOU WOULD LIKE TO SPEAK WITH THE DIRECTOR OF INSPECTION CONCERNING THIS

REPORT, CALL NATIONWIDE TOWERCOMPANY AT PH. (270) 869-8000. ADDITIONAL COPIES OF THIS REPORT ARE AVAILABLE. 11

©2002. NATIONWIDE TOWER COMPANY.

Since 1987

SITE NAME: Bobby MullerINSPECTOR:La PlataJOB NO: INSPECTION DATE:KDU1036905Z 2/7/2003

THIS SITE IS IN SEISMIC ZONE: 0 MDTHS SITE IS IN THE STATE OF:

IF YOU WOULD LIKE TO SPEAK WITH THE DIRECTOR OF INSPECTION CONCERNING THIS

REPORT, CALL NATIONWIDE TOWERCOMPANY AT PH. (270) 869-8000. ADDITIONAL COPIES OF THIS REPORT ARE AVAILABLE. 12

©2002. NATIONWIDE TOWER COMPANY.

JOB NO.: KDU1036905Z INSPECTION DATE: 2/7/03 SITE ID: LA PLATA MD INSPECTOR: BOBBY MULLER

Photo shows elevation.

JOB NO.: KDU1036905Z INSPECTION DATE: 2/7/03 SITE ID: LA PLATA MD INSPECTOR: BOBBY MULLER

Photo shows west building.

Photo shows northwest building.

JOB NO.: KDU1036905Z INSPECTION DATE: 2/7/03 SITE ID: LA PLATA MD INSPECTOR: BOBBY MULLER

Photo shows west building.

Photo shows building.

JOB NO.: KDU1036905Z INSPECTION DATE: 2/7/03 SITE ID: LA PLATA MD INSPECTOR: BOBBY MULLER

Photo shows access road.

Photo shows site entrance. There is no RF radiation warning and/or dangerous high voltage equipment signs posted in accordance with OSHA and TIA/EIA 222F standards.

JOB NO.: KDU1036905Z INSPECTION DATE: 2/7/03 SITE ID: LA PLATA MD INSPECTOR: BOBBY MULLER

Photo shows top of the tower.

Photo shows mid section of the tower.

JOB NO.: KDU1036905Z INSPECTION DATE: 2/7/03 SITE ID: LA PLATA MD INSPECTOR: BOBBY MULLER

Photo shows bottom section of the tower.

Photo shows top west section of the tower.

JOB NO.: KDU1036905Z INSPECTION DATE: 2/7/03 SITE ID: LA PLATA MD INSPECTOR: BOBBY MULLER

Perimeter fence is damaged. We recommend that the fence be repaired or replaced. Perimeter fence not grounded. We recommend furnishing and installing grounding in accordance with OSHA 29 CFR 1910.308 and TIA/EIA 222 F Standard, Section 12.1.3.

Photo shows entry port.

JOB NO.: KDU1036905Z INSPECTION DATE: 2/7/03 SITE ID: LA PLATA MD INSPECTOR: BOBBY MULLER

Photo shows entry port.

Feedlines do not have a waveguide/ice bridge. The bridge serves to support and protect the feedlines. We recommend furnishing and installing a waveguide/ice bridge from the tower to the building in accordance with EIA/TIA 222 F Standards.

JOB NO.: KDU1036905Z INSPECTION DATE: 12/7/03 SITE ID: LA PLATA MD INSPECTOR: BOBBY MULLER

Lighting conduit broken. This is allowing water to enter the lighting system. We recommend replacing the conduit in accordance with FAA.

Rusty lighting conduit fittings. We recommend that the fittings be wire brushed and cold galvanized in accordance with FAA.

JOB NO.: KDU1036905Z INSPECTION DATE: 2/7/03 SITE ID: LA PLATA MD INSPECTOR: BOBBY MULLER

Waveguide/coax not properly grounded at top and bottom of run. We recommend furnishing and installing grounding per OSHA 29 CFR 1910.308 and TIA/EIA 222 F Standard, Section 12.1.3.

Feedlines do not run straight. We recommend furnishing and installing a waveguide ladder or properly securing the lines at appropriate intervals in accordance with TIA/EIA 222 F Standards.

JOB NO.: KDU1036905Z INSPECTION DATE: 2/7/03 SITE ID: LA PLATA MD INSPECTOR: BOBBY MULLER

Photo shows bottom of platform at the 150’ level.

Photo shows bottom of platform.

JOB NO.: KDU1036905Z INSPECTION DATE: 2/7/03 SITE ID: LA PLATA MD INSPECTOR: BOBBY MULLER

Photo shows 1st level of tower bracing.

Photo shows 1st platform.

JOB NO.: KDU1036905Z INSPECTION DATE: 2/7/03 SITE ID: LA PLATA MD INSPECTOR: BOBBY MULLER

Photo shows 2nd platform.

Photo shows 2nd set of stairs.

JOB NO.: KDU1036905Z INSPECTION DATE: 2/7/03 SITE ID: LA PLATA MD INSPECTOR: BOBBY MULLER

Photo shows 3rd level of bracing.

Photo shows 3rd set of stairs.

JOB NO.: KDU1036905Z INSPECTION DATE: 2/7/03 SITE ID: LA PLATA MD INSPECTOR: BOBBY MULLER

Photo shows bracing at the 5th level.

Photo shows bracing at the 5th level.

JOB NO.: KDU1036905Z INSPECTION DATE: 2/7/03 SITE ID: LA PLATA MD INSPECTOR: BOBBY MULLER

Photo shows 4th level of bracing.

Photo shows 4th set of stairs.

JOB NO.: KDU1036905Z INSPECTION DATE: 2/7/03 SITE ID: LA PLATA MD INSPECTOR: BOBBY MULLER

Photo shows inside of tower.

Photo shows bent flat iron and rusty bolts. We recommend repairing/replacing the flat iron and to wire brush/cold galvanize and/or to replace the bolts as necessary.

JOB NO.: KDU1036905Z INSPECTION DATE: 2/7/03 SITE ID: LA PLATA MD INSPECTOR: BOBBY MULLER

Bolts securing top platform are loose. We recommend tightening all loose bolts to proper torque value in accordance with TIA/EIA 222F standards. Paint is faded and chipping. We recommend cleaning and painting the tower in accordance with FAA daymarking standards.

Photo shows bracing at the 5th level.

JOB NO.: KDU1036905Z INSPECTION DATE: 2/7/03 SITE ID: LA PLATA MD INSPECTOR: BOBBY MULLER

Photo shows bracing at the 6th level.

Photo shows bracing.

JOB NO.: KDU1036905Z INSPECTION DATE: 2/7/03 SITE ID: LA PLATA MD INSPECTOR: BOBBY MULLER

Photo shows angle splice to middle of bay.

Tower is not equipped with a safety climb device. This is an OSHA violation. We recommend furnishing and installing an OSHA approved safety climb device.

JOB NO.: KDU1036905Z INSPECTION DATE: 2/7/03 SITE ID: LA PLATA MD INSPECTOR: BOBBY MULLER

Photo shows inside of the tower.

Photo shows inside of the tower.

JOB NO.: KDU1036905Z INSPECTION DATE: 2/7/03 SITE ID: LA PLATA MD INSPECTOR: BOBBY MULLER

Photo shows inside of the tower.

Photo shows unused coax being secured by rope. We recommend removing all unused lines from the tower.

JOB NO.: KDU1036905Z INSPECTION DATE: 2/7/03 SITE ID: LA PLATA MD INSPECTOR: BOBBY MULLER

Photo shows tower bracing.

Photo shows antennas.

JOB NO.: KDU1036905Z INSPECTION DATE: 2/7/03 SITE ID: LA PLATA MD INSPECTOR: BOBBY MULLER

Photo shows antennas.

Photo shows antennas.

JOB NO.: KDU1036905Z INSPECTION DATE: 2/7/03 SITE ID: LA PLATA MD INSPECTOR: BOBBY MULLER

Photo shows antennas.

Photo shows antennas.

JOB NO.: KDU1036905Z INSPECTION DATE: 2/7/03 SITE ID: LA PLATA MD INSPECTOR: BOBBY MULLER

Photo shows antennas.

Photo shows antennas.

JOB NO.: KDU1036905Z INSPECTION DATE: 2/7/03 SITE ID: LA PLATA MD INSPECTOR: BOBBY MULLER

Photo shows antennas.

Photo shows antennas.

JOB NO.: KDU1036905Z INSPECTION DATE: 2/7/03 SITE ID: LA PLATA MD INSPECTOR: BOBBY MULLER

Photo shows antennas.

Photo shows antennas.

JOB NO.: KDU1036905Z INSPECTION DATE: 2/7/03 SITE ID: LA PLATA MD INSPECTOR: BOBBY MULLER

Photo shows antennas.

Photo shows view from face A of the tower.

JOB NO.: KDU1036905Z INSPECTION DATE: 2/7/03 SITE ID: LA PLATA MD INSPECTOR: BOBBY MULLER

Photo shows view from face B of the tower.

Photo shows view from face C of the tower.

JOB NO.: KDU1036905Z INSPECTION DATE: 2/7/03 SITE ID: LA PLATA MD INSPECTOR: BOBBY MULLER

Photo shows top beacon.