NDT CODE BOOK FOR ASME SECTION 1 ASME B31.1 ASME B31.3 ASME SECTION 5 ASME SECTION 8 AWS D1.1 API 1104 MASTER COPY
Transcript
Page 1: NDT Code Book Made Easy

NDT CODE BOOK FOR

ASME SECTION 1 ASME B31.1 ASME B31.3

ASME SECTION 5 ASME SECTION 8

AWS D1.1 API 1104

MASTER COPY

Page 2: NDT Code Book Made Easy

PENETRAMETER SELECTIONNote: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Wire: 0.008 Esn. Wire: A2 S/S Hole: 12

F/S Wire: 0.006 Esn. Wire: A3 F/S Hole: 10Welds with reinforcement: S/S Wire: 0.008 Esn. Wire: A2 S/S Hole: 12

F/S Wire: 0.006 Esn. Wire: A3 F/S Hole: 10Maximum allowable reinforcement: 0.0625"/per sideMaximum reinforcement with DWE/SWV: 0.125" Total of walls + reinforcement: 0.343" 16.8402 mmMaximum reinforcement with DWE/DWV: 0.125" Total of walls + reinforcement: 0.343" 16.8402 mmMaximum reinforcement with SWE/SWV: 0.0625" Total of wall + reinforcement: 0.172" 4.3688 mm

INADEQUATE PENETRATION WITHOUT HIGH LOWMaximum length of individual indication of IP : 1 inch or 25mmMaximum length of IP in 8% of weld: 15.1770 mmMaximum length of indications in any continuous 12" length of weld: N/A since total weld is under 12 inches

INADEQUATE PENETRATION DUE TO HIGH LOWMaximum length of individual indication of IPD: 2 inches or 50mmMaximum length of indications of IPD in any continuous 12" length of weld: N/A since total weld is under 12 inches.

INADEQUATE CROSS PENETRATIONMaximum length of an individual indication of ICP: 2 inches or 50mmMaximum length of indications of ICP in any continuous 12" length of weld: N/A since total weld is under 12 inches.

INCOMPLETE FUSIONMaximum length of an individual indication of IF: 1 inch or 25mmMaximum length of IF in 8% of weld: 15.1770 mmMaximum length of indications of IF in any continuous 12" length of weld: N/A since total weld is under 12 inches.

INCOMPLETE FUSION DUE TO COLD LAPMaximum length of individual indications of IFD: 2 inches or 50mmMaximum length of IFD in 8% of weld: 15.1770mmMaximum length of indications of IFD in any continuous 12" length of weld: N/A since total weld is under 12 inches.

INTERNAL CONCAVITY Any length of IC is acceptable, provided the density of the radiographic image of the internal concavity does not exceed that of the thinnest adjacent parent material. For areas that exceed the density of thethinnest adjacent parent material, the criteria for burn through are applicable.

BURN - THROUGHMaximum dimension of BT's image : unacceptable if it exceeds that of the thinnest adjacent parent metal.Maximum dimension of BT: 1/4" or 6mmMaximum dimension is unacceptable if: it exceeds the thinner of the nonnal wall thickness joined, and the density

of the BT's image exceeds that of the thinnest adjacent parent material.The sum of the max dimensions of separate BBT's whose image density exceeds that of the thinnest adjacent parentmaterial exceeds 1/2 inch or 13mm in any continuous 12" length of weld or the total weld length(whichever is less).

API - 11042" s/10 - 0.109" Wall

Page 1 of 2

Page 3: NDT Code Book Made Easy

API - 11042" s/10 - 0.109" Wall

SLAG INCLUSIONSElongated slag inclusions (ESI)Maximum length of an ESI: 2 inches or 50mmParallel ESI indications (Wagon Tracks) shall be considered a single indication unless the width of either of them exceed1/32" or 0.8mm. In that event they shall be considered separate indications.Maximum length of ESI indications in any continuous 12" length of weld: N/A since total weld is under 12 inches.Maximum width of an individual ESI indication: 1/16" or 1.6mmIsolated slag inclusions (ISI)Maximum length of ISI indications in any continuous 12" length of weld: N/A since total weld is under 12 inches.Maximum width of an ISI indication: 1/8" or 3mmMaximum length of ESI and ISI in 8% of weld: 15.1770mm

POROSITY Individual or Scattered Porosity.Maximum size of an individual pore: 1/8" or 3mmThe size of an individual pore exceeds 25% of the thinner of the nonimal wall thickness joined.The distribution of scattered porosity exceeds the concentration permitted in Figures 19 or 20.Cluster Porosity (CP)Maximum diameter of the cluster: 1/2 inch or 13mmMaximum length of CP indications in any continuous 12" length of weweld: N/A since total weld is under 12 inches.Maximum length of an individual pore within a cluster: 1/16 inch or 2mmHollow Bead Porosity (HB)Maximum length of an individual indication of HB: 1/2 inch or 13mmMaximum length of HB indications in any continuous 12" length of weld: N/A since total weld is under 12 inches.Maximum length of HB in 8% of weld: 15.1770mmNOTE: The weld is unacceptable if individual indications of HB, each greater than 1/4 inch or 6mm in length, are seperated by less than 2 inches or 50 mm.

CRACKSNote: Any crack which is not a shallow crater crack or star crack is unacceptable.Maximum length of shallow crater cracks or star cracks: 5/32 inch or 4mm

UNDERCUTTINGUndercutting adjacent to the cover pass (EU) and Undercutting adjacent to the root pass (IU)Maximum length of EU and IU indications (in any combination) in a 12 inch length of weld: N/AMaximum length of EU and IU indications: 1.244 inches or 35.6 mm (This value is 1/6 th of the total weld length)

ACCUMULATION OF IMPERFECTIONSMaximum length of AI indications in any continuous 12 inch or 300 mm length of weld: N/AMaximum length of AI indications of 8% of weld: 15.1770mm

RADIOGRAPHIC INFOPipe O.D. in inches: 2.375Amount of Penetrameters required for each shot: 1 penny in the center of the weldTotal weld length: 7.469" 189.7126mmCassette size to complete weld in most efficient way: 3.5 x 10"Amount of shots to complete weld with 1" on each side of readable film: 38% of weld: 0.59752" 15.1770mmHole penetrameters are adjacent to the weld and Wire penetrameters are parallel to the weld.

Page 2 of 2

Page 4: NDT Code Book Made Easy

PENETRAMETER SELECTIONNote: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Wire: 0.008 Esn. Wire: A2 S/S Hole: 12

F/S Wire: 0.006 Esn. Wire: A3 F/S Hole: 10Welds with reinforcement: S/S Wire: 0.008 Esn. Wire: A2 S/S Hole: 12

F/S Wire: 0.006 Esn. Wire: A3 F/S Hole: 10Maximum allowable reinforcement: 0.0625"/per sideMaximum reinforcement with DWE/SWV: 0.125" Total of walls + reinforcement: 0.433" 10.9982 mmMaximum reinforcement with DWE/DWV: 0.125" Total of walls + reinforcement: 0.433" 10.9982 mmMaximum reinforcement with SWE/SWV: 0.0625" Total of wall + reinforcement: 0.217" 5.5118 mm

INADEQUATE PENETRATION WITHOUT HIGH LOWMaximum length of individual indication of IP : 1 inch or 25mmMaximum length of IP in 8% of weld: 15.1770 mmMaximum length of indications in any continuous 12" length of weld: N/A since total weld is under 12 inches

INADEQUATE PENETRATION DUE TO HIGH LOWMaximum length of individual indication of IPD: 2 inches or 50mmMaximum length of indications of IPD in any continuous 12" length of weld: N/A since total weld is under 12 inches.

INADEQUATE CROSS PENETRATIONMaximum length of an individual indication of ICP: 2 inches or 50mmMaximum length of indications of ICP in any continuous 12" length of weld: N/A since total weld is under 12 inches.

INCOMPLETE FUSIONMaximum length of an individual indication of IF: 1 inch or 25mmMaximum length of IF in 8% of weld: 15.1770 mmMaximum length of indications of IF in any continuous 12" length of weld: N/A since total weld is under 12 inches.

INCOMPLETE FUSION DUE TO COLD LAPMaximum length of individual indications of IFD: 2 inches or 50mmMaximum length of IFD in 8% of weld: 15.1770mmMaximum length of indications of IFD in any continuous 12" length of weld: N/A since total weld is under 12 inches.

INTERNAL CONCAVITY Any length of IC is acceptable, provided the density of the radiographic image of the internal concavity does not exceed that of the thinnest adjacent parent material. For areas that exceed the density of thethinnest adjacent parent material, the criteria for burn through are applicable.

BURN - THROUGHMaximum dimension of BT's image : unacceptable if it exceeds that of the thinnest adjacent parent metal.Maximum dimension of BT: 1/4" or 6mmMaximum dimension is unacceptable if: it exceeds the thinner of the nonnal wall thickness joined, and the density

of the BT's image exceeds that of the thinnest adjacent parent material.The sum of the max dimensions of separate BBT's whose image density exceeds that of the thinnest adjacent parentmaterial exceeds 1/2 inch or 13mm in any continuous 12" length of weld or the total weld length(whichever is less).

API - 11042" s/40 & Std. - 0.154" Wall

Page 1 of 2

Page 5: NDT Code Book Made Easy

API - 11042" s/40 & Std. - 0.154" Wall

SLAG INCLUSIONSElongated slag inclusions (ESI)Maximum length of an ESI: 2 inches or 50mmParallel ESI indications (Wagon Tracks) shall be considered a single indication unless the width of either of them exceed1/32" or 0.8mm. In that event they shall be considered separate indications.Maximum length of ESI indications in any continuous 12" length of weld: N/A since total weld is under 12 inches.Maximum width of an individual ESI indication: 1/16" or 1.6mmIsolated slag inclusions (ISI)Maximum length of ISI indications in any continuous 12" length of weld: N/A since total weld is under 12 inches.Maximum width of an ISI indication: 1/8" or 3mmMaximum length of ESI and ISI in 8% of weld: 15.1770mm

POROSITY Individual or Scattered Porosity.Maximum size of an individual pore: 1/8" or 3mmThe size of an individual pore exceeds 25% of the thinner of the nonimal wall thickness joined.The distribution of scattered porosity exceeds the concentration permitted in Figures 19 or 20.Cluster Porosity (CP)Maximum diameter of the cluster: 1/2 inch or 13mmMaximum length of CP indications in any continuous 12" length of weweld: N/A since total weld is under 12 inches.Maximum length of an individual pore within a cluster: 1/16 inch or 2mmHollow Bead Porosity (HB)Maximum length of an individual indication of HB: 1/2 inch or 13mmMaximum length of HB indications in any continuous 12" length of weld: N/A since total weld is under 12 inches.Maximum length of HB in 8% of weld: 15.1770mmNOTE: The weld is unacceptable if individual indications of HB, each greater than 1/4 inch or 6mm in length, are seperated by less than 2 inches or 50 mm.

CRACKSNote: Any crack which is not a shallow crater crack or star crack is unacceptable.Maximum length of shallow crater cracks or star cracks: 5/32 inch or 4mm

UNDERCUTTINGUndercutting adjacent to the cover pass (EU) and Undercutting adjacent to the root pass (IU)Maximum length of EU and IU indications (in any combination) in a 12 inch length of weld: N/AMaximum length of EU and IU indications: 1.244 inches or 35.6 mm (This value is 1/6 th of the total weld length)

ACCUMULATION OF IMPERFECTIONSMaximum length of AI indications in any continuous 12 inch or 300 mm length of weld: N/AMaximum length of AI indications of 8% of weld: 15.1770mm

RADIOGRAPHIC INFOPipe O.D. in inches: 2.375Amount of Penetrameters required for each shot: 1 penny in the center of the weldTotal weld length: 7.469" 189.7126 mmCassette size to complete weld in most efficient way: 3.5 x 10"Amount of shots to complete weld with 1" on each side of readable film: 38% of weld: 0.59752" 15.1770mmHole penetrameters are adjacent to the weld and Wire penetrameters are parallel to the weld.

Page 2 of 2

Page 6: NDT Code Book Made Easy

PENETRAMETER SELECTIONNote: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Wire: 0.008 Esn. Wire: A2 S/S Hole: 12

F/S Wire: 0.006 Esn. Wire: A3 F/S Hole: 10Welds with reinforcement: S/S Wire: 0.010 Esn. Wire: A1 or B6 S/S Hole: 15

F/S Wire: 0.008 Esn. Wire: A2 F/S Hole: 12Maximum allowable reinforcement: 0.0625"/per sideMaximum reinforcement with DWE/SWV: 0.125" Total of walls + reinforcement: 0.561" 14.2494 mmMaximum reinforcement with DWE/DWV: 0.125" Total of walls + reinforcement: 0.561" 14.2494 mmMaximum reinforcement with SWE/SWV: 0.0625" Total of wall + reinforcement: 0.281" 7.1374

INADEQUATE PENETRATION WITHOUT HIGH LOWMaximum length of individual indication of IP : 1 inch or 25mmMaximum length of IP in 8% of weld: 15.1770 mmMaximum length of indications in any continuous 12" length of weld: N/A since total weld is under 12 inches

INADEQUATE PENETRATION DUE TO HIGH LOWMaximum length of individual indication of IPD: 2 inches or 50mmMaximum length of indications of IPD in any continuous 12" length of weld: N/A since total weld is under 12 inches.

INADEQUATE CROSS PENETRATIONMaximum length of an individual indication of ICP: 2 inches or 50mmMaximum length of indications of ICP in any continuous 12" length of weld: N/A since total weld is under 12 inches.

INCOMPLETE FUSIONMaximum length of an individual indication of IF: 1 inch or 25mmMaximum length of IF in 8% of weld: 15.1770 mmMaximum length of indications of IF in any continuous 12" length of weld: N/A since total weld is under 12 inches.

INCOMPLETE FUSION DUE TO COLD LAPMaximum length of individual indications of IFD: 2 inches or 50mmMaximum length of IFD in 8% of weld: 15.1770mmMaximum length of indications of IFD in any continuous 12" length of weld: N/A since total weld is under 12 inches.

INTERNAL CONCAVITY Any length of IC is acceptable, provided the density of the radiographic image of the internal concavity does not exceed that of the thinnest adjacent parent material. For areas that exceed the density of thethinnest adjacent parent material, the criteria for burn through are applicable.

BURN - THROUGHMaximum dimension of BT's image : unacceptable if it exceeds that of the thinnest adjacent parent metal.Maximum dimension of BT: 1/4" or 6mmMaximum dimension is unacceptable if: it exceeds the thinner of the nonnal wall thickness joined, and the density

of the BT's image exceeds that of the thinnest adjacent parent material.The sum of the max dimensions of separate BBT's whose image density exceeds that of the thinnest adjacent parentmaterial exceeds 1/2 inch or 13mm in any continuous 12" length of weld or the total weld length(whichever is less).

API - 11042" s/80 & Extra Strong - 0.218" Wall

Page 1 of 2

Page 7: NDT Code Book Made Easy

API - 11042" s/80 & Extra Strong - 0.218" Wall

SLAG INCLUSIONSElongated slag inclusions (ESI)Maximum length of an ESI: 2 inches or 50mmParallel ESI indications (Wagon Tracks) shall be considered a single indication unless the width of either of them exceed1/32" or 0.8mm. In that event they shall be considered separate indications.Maximum length of ESI indications in any continuous 12" length of weld: N/A since total weld is under 12 inches.Maximum width of an individual ESI indication: 1/16" or 1.6mmIsolated slag inclusions (ISI)Maximum length of ISI indications in any continuous 12" length of weld: N/A since total weld is under 12 inches.Maximum width of an ISI indication: 1/8" or 3mmMaximum length of ESI and ISI in 8% of weld: 15.1770mm

POROSITY Individual or Scattered Porosity.Maximum size of an individual pore: 1/8" or 3mmThe size of an individual pore exceeds 25% of the thinner of the nonimal wall thickness joined.The distribution of scattered porosity exceeds the concentration permitted in Figures 19 or 20.Cluster Porosity (CP)Maximum diameter of the cluster: 1/2 inch or 13mmMaximum length of CP indications in any continuous 12" length of weweld: N/A since total weld is under 12 inches.Maximum length of an individual pore within a cluster: 1/16 inch or 2mmHollow Bead Porosity (HB)Maximum length of an individual indication of HB: 1/2 inch or 13mmMaximum length of HB indications in any continuous 12" length of weld: N/A since total weld is under 12 inches.Maximum length of HB in 8% of weld: 15.1770mmNOTE: The weld is unacceptable if individual indications of HB, each greater than 1/4 inch or 6mm in length, are seperated by less than 2 inches or 50 mm.

CRACKSNote: Any crack which is not a shallow crater crack or star crack is unacceptable.Maximum length of shallow crater cracks or star cracks: 5/32 inch or 4mm

UNDERCUTTINGUndercutting adjacent to the cover pass (EU) and Undercutting adjacent to the root pass (IU)Maximum length of EU and IU indications (in any combination) in a 12 inch length of weld: N/AMaximum length of EU and IU indications: 1.244 inches or 35.6 mm (This value is 1/6 th of the total weld length)

ACCUMULATION OF IMPERFECTIONSMaximum length of AI indications in any continuous 12 inch or 300 mm length of weld: N/AMaximum length of AI indications of 8% of weld: 15.1770mm

RADIOGRAPHIC INFOPipe O.D. in inches: 2.375Amount of Penetrameters required for each shot: 1 penny in the center of the weldTotal weld length: 7.469" 189.7126 mmCassette size to complete weld in most efficient way: 3.5 x 10"Amount of shots to complete weld with 1" on each side of readable film: 38% of weld: 0.59752" 15.1770mmHole penetrameters are adjacent to the weld and Wire penetrameters are parallel to the weld.

Page 2 of 2

Page 8: NDT Code Book Made Easy

PENETRAMETER SELECTIONNote: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Wire: 0.010 Esn. Wire: A1 or B6 S/S Hole: 15

F/S Wire: 0.008 Esn. Wire: A2 F/S Hole: 12Welds with reinforcement: S/S Wire: 0.013 Esn. Wire: B5 S/S Hole: 17

F/S Wire: 0.010 Esn. Wire: A1 or B6 F/S Hole: 15Maximum allowable reinforcement: 0.0625"/per sideMaximum reinforcement with DWE/SWV: 0.125" Total of walls + reinforcement: 0.813" 20.6502 mmMaximum reinforcement with DWE/DWV: 0.125" Total of walls + reinforcement: 0.813" 20.6502 mmMaximum reinforcement with SWE/SWV: 0.0625" Total of wall + reinforcement: 0.407" 10.3378 mm

INADEQUATE PENETRATION WITHOUT HIGH LOWMaximum length of individual indication of IP : 1 inch or 25mmMaximum length of IP in 8% of weld: 15.1770 mmMaximum length of indications in any continuous 12" length of weld: N/A since total weld is under 12 inches

INADEQUATE PENETRATION DUE TO HIGH LOWMaximum length of individual indication of IPD: 2 inches or 50mmMaximum length of indications of IPD in any continuous 12" length of weld: N/A since total weld is under 12 inches.

INADEQUATE CROSS PENETRATIONMaximum length of an individual indication of ICP: 2 inches or 50mmMaximum length of indications of ICP in any continuous 12" length of weld: N/A since total weld is under 12 inches.

INCOMPLETE FUSIONMaximum length of an individual indication of IF: 1 inch or 25mmMaximum length of IF in 8% of weld: 15.1770 mmMaximum length of indications of IF in any continuous 12" length of weld: N/A since total weld is under 12 inches.

INCOMPLETE FUSION DUE TO COLD LAPMaximum length of individual indications of IFD: 2 inches or 50mmMaximum length of IFD in 8% of weld: 15.1770mmMaximum length of indications of IFD in any continuous 12" length of weld: N/A since total weld is under 12 inches.

INTERNAL CONCAVITY Any length of IC is acceptable, provided the density of the radiographic image of the internal concavity does not exceed that of the thinnest adjacent parent material. For areas that exceed the density of thethinnest adjacent parent material, the criteria for burn through are applicable.

BURN - THROUGHMaximum dimension of BT's image : unacceptable if it exceeds that of the thinnest adjacent parent metal.Maximum dimension of BT: 1/4" or 6mmMaximum dimension is unacceptable if: it exceeds the thinner of the nonnal wall thickness joined, and the density

of the BT's image exceeds that of the thinnest adjacent parent material.The sum of the max dimensions of separate BBT's whose image density exceeds that of the thinnest adjacent parentmaterial exceeds 1/2 inch or 13mm in any continuous 12" length of weld or the total weld length(whichever is less).

API - 11042" s/160 - 0.344" Wall

Page 1 of 2

Page 9: NDT Code Book Made Easy

API - 11042" s/160 - 0.344" Wall

SLAG INCLUSIONSElongated slag inclusions (ESI)Maximum length of an ESI: 2 inches or 50mmParallel ESI indications (Wagon Tracks) shall be considered a single indication unless the width of either of them exceed1/32" or 0.8mm. In that event they shall be considered separate indications.Maximum length of ESI indications in any continuous 12" length of weld: N/A since total weld is under 12 inches.Maximum width of an individual ESI indication: 1/16" or 1.6mmIsolated slag inclusions (ISI)Maximum length of ISI indications in any continuous 12" length of weld: N/A since total weld is under 12 inches.Maximum width of an ISI indication: 1/8" or 3mmMaximum length of ESI and ISI in 8% of weld: 15.1770mm

POROSITY Individual or Scattered Porosity.Maximum size of an individual pore: 1/8" or 3mmThe size of an individual pore exceeds 25% of the thinner of the nonimal wall thickness joined.The distribution of scattered porosity exceeds the concentration permitted in Figures 19 or 20.Cluster Porosity (CP)Maximum diameter of the cluster: 1/2 inch or 13mmMaximum length of CP indications in any continuous 12" length of weweld: N/A since total weld is under 12 inches.Maximum length of an individual pore within a cluster: 1/16 inch or 2mmHollow Bead Porosity (HB)Maximum length of an individual indication of HB: 1/2 inch or 13mmMaximum length of HB indications in any continuous 12" length of weld: N/A since total weld is under 12 inches.Maximum length of HB in 8% of weld: 15.1770mmNOTE: The weld is unacceptable if individual indications of HB, each greater than 1/4 inch or 6mm in length, are seperated by less than 2 inches or 50 mm.

CRACKSNote: Any crack which is not a shallow crater crack or star crack is unacceptable.Maximum length of shallow crater cracks or star cracks: 5/32 inch or 4mm

UNDERCUTTINGUndercutting adjacent to the cover pass (EU) and Undercutting adjacent to the root pass (IU)Maximum length of EU and IU indications (in any combination) in a 12 inch length of weld: N/AMaximum length of EU and IU indications: 1.244 inches or 35.6 mm (This value is 1/6 th of the total weld length)

ACCUMULATION OF IMPERFECTIONSMaximum length of AI indications in any continuous 12 inch or 300 mm length of weld: N/AMaximum length of AI indications of 8% of weld: 15.1770mm

RADIOGRAPHIC INFOPipe O.D. in inches: 2.375Amount of Penetrameters required for each shot: 1 penny in the center of the weldTotal weld length: 7.469" 189.7126 mmCassette size to complete weld in most efficient way: 3.5 x 10"Amount of shots to complete weld with 1" on each side of readable film: 48% of weld: 0.59752" 15.1770mmHole penetrameters are adjacent to the weld and Wire penetrameters are parallel to the weld.

Page 2 of 2

Page 10: NDT Code Book Made Easy

PENETRAMETER SELECTIONNote: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Wire: 0.013 Esn. Wire: B5 S/S Hole: 17

F/S Wire: 0.010 Esn. Wire: A1 or B6 F/S Hole: 15Welds with reinforcement: S/S Wire: 0.016 Esn. Wire: B4 S/S Hole: 20

F/S Wire: 0.013 Esn. Wire: B5 F/S Hole: 17Maximum allowable reinforcement: 0.0625"/per sideMaximum reinforcement with DWE/SWV: 0.125" Total of walls + reinforcement: 0.997" 25.3238 mmMaximum reinforcement with DWE/DWV: 0.125" Total of walls + reinforcement: 0.997" 25.3238 mmMaximum reinforcement with SWE/SWV: 0.0625" Total of wall + reinforcement: 0.499" 12.6746 mm

INADEQUATE PENETRATION WITHOUT HIGH LOWMaximum length of individual indication of IP : 1 inch or 25mmMaximum length of IP in 8% of weld: 15.1770 mmMaximum length of indications in any continuous 12" length of weld: N/A since total weld is under 12 inches

INADEQUATE PENETRATION DUE TO HIGH LOWMaximum length of individual indication of IPD: 2 inches or 50mmMaximum length of indications of IPD in any continuous 12" length of weld: N/A since total weld is under 12 inches.

INADEQUATE CROSS PENETRATIONMaximum length of an individual indication of ICP: 2 inches or 50mmMaximum length of indications of ICP in any continuous 12" length of weld: N/A since total weld is under 12 inches.

INCOMPLETE FUSIONMaximum length of an individual indication of IF: 1 inch or 25mmMaximum length of IF in 8% of weld: 15.1770 mmMaximum length of indications of IF in any continuous 12" length of weld: N/A since total weld is under 12 inches.

INCOMPLETE FUSION DUE TO COLD LAPMaximum length of individual indications of IFD: 2 inches or 50mmMaximum length of IFD in 8% of weld: 15.1770mmMaximum length of indications of IFD in any continuous 12" length of weld: N/A since total weld is under 12 inches.

INTERNAL CONCAVITY Any length of IC is acceptable, provided the density of the radiographic image of the internal concavity does not exceed that of the thinnest adjacent parent material. For areas that exceed the density of thethinnest adjacent parent material, the criteria for burn through are applicable.

BURN - THROUGHMaximum dimension of BT's image : unacceptable if it exceeds that of the thinnest adjacent parent metal.Maximum dimension of BT: 1/4" or 6mmMaximum dimension is unacceptable if: it exceeds the thinner of the nonnal wall thickness joined, and the density

of the BT's image exceeds that of the thinnest adjacent parent material.The sum of the max dimensions of separate BBT's whose image density exceeds that of the thinnest adjacent parentmaterial exceeds 1/2 inch or 13mm in any continuous 12" length of weld or the total weld length(whichever is less).

API - 11042" XX Strong - 0.436" Wall

Page 1 of 2

Page 11: NDT Code Book Made Easy

API - 11042" XX Strong - 0.436" Wall

SLAG INCLUSIONSElongated slag inclusions (ESI)Maximum length of an ESI: 2 inches or 50mmParallel ESI indications (Wagon Tracks) shall be considered a single indication unless the width of either of them exceed1/32" or 0.8mm. In that event they shall be considered separate indications.Maximum length of ESI indications in any continuous 12" length of weld: N/A since total weld is under 12 inches.Maximum width of an individual ESI indication: 1/16" or 1.6mmIsolated slag inclusions (ISI)Maximum length of ISI indications in any continuous 12" length of weld: N/A since total weld is under 12 inches.Maximum width of an ISI indication: 1/8" or 3mmMaximum length of ESI and ISI in 8% of weld: 15.1770mm

POROSITY Individual or Scattered Porosity.Maximum size of an individual pore: 1/8" or 3mmThe size of an individual pore exceeds 25% of the thinner of the nonimal wall thickness joined.The distribution of scattered porosity exceeds the concentration permitted in Figures 19 or 20.Cluster Porosity (CP)Maximum diameter of the cluster: 1/2 inch or 13mmMaximum length of CP indications in any continuous 12" length of weweld: N/A since total weld is under 12 inches.Maximum length of an individual pore within a cluster: 1/16 inch or 2mmHollow Bead Porosity (HB)Maximum length of an individual indication of HB: 1/2 inch or 13mmMaximum length of HB indications in any continuous 12" length of weld: N/A since total weld is under 12 inches.Maximum length of HB in 8% of weld: 15.1770mmNOTE: The weld is unacceptable if individual indications of HB, each greater than 1/4 inch or 6mm in length, are seperated by less than 2 inches or 50 mm.

CRACKSNote: Any crack which is not a shallow crater crack or star crack is unacceptable.Maximum length of shallow crater cracks or star cracks: 5/32 inch or 4mm

UNDERCUTTINGUndercutting adjacent to the cover pass (EU) and Undercutting adjacent to the root pass (IU)Maximum length of EU and IU indications (in any combination) in a 12 inch length of weld: N/AMaximum length of EU and IU indications: 1.244 inches or 35.6 mm (This value is 1/6 th of the total weld length)

ACCUMULATION OF IMPERFECTIONSMaximum length of AI indications in any continuous 12 inch or 300 mm length of weld: N/AMaximum length of AI indications of 8% of weld: 15.1770mm

RADIOGRAPHIC INFOPipe O.D. in inches: 2.375Amount of Penetrameters required for each shot: 1 penny in the center of the weldTotal weld length: 7.469" 189.7126 mmCassette size to complete weld in most efficient way: 3.5 x 10"Amount of shots to complete weld with 1" on each side of readable film: 48% of weld: 0.59752" 15.1770mmHole penetrameters are adjacent to the weld and Wire penetrameters are parallel to the weld.

Page 2 of 2

Page 12: NDT Code Book Made Easy

PENETRAMETER SELECTIONNote: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Wire: 0.008 Esn. Wire: A2 S/S Hole: 12

F/S Wire: 0.006 Esn. Wire: A3 F/S Hole: 10Welds with reinforcement: S/S Wire: 0.008 Esn. Wire: A2 S/S Hole: 12

F/S Wire: 0.006 Esn. Wire: A3 F/S Hole: 10Maximum allowable reinforcement: 0.0625"/per sideMaximum reinforcement with DWE/SWV: 0.125" Total of walls + reinforcement: 0.365" 9.2710 mmMaximum reinforcement with DWE/DWV: 0.125" Total of walls + reinforcement: 0.365" 9.2710 mmMaximum reinforcement with SWE/SWV: 0.0625" Total of wall + reinforcement: 0.183" 4.6482 mm

INADEQUATE PENETRATION WITHOUT HIGH LOWMaximum length of individual indication of IP : 1 inch or 25mmMaximum length of IP in 8% of weld: 22.3672 mmMaximum length of indications in any continuous 12" length of weld: N/A since total weld is under 12 inches

INADEQUATE PENETRATION DUE TO HIGH LOWMaximum length of individual indication of IPD: 2 inches or 50mmMaximum length of indications of IPD in any continuous 12" length of weld: N/A since total weld is under 12 inches.

INADEQUATE CROSS PENETRATIONMaximum length of an individual indication of ICP: 2 inches or 50mmMaximum length of indications of ICP in any continuous 12" length of weld: N/A since total weld is under 12 inches.

INCOMPLETE FUSIONMaximum length of an individual indication of IF: 1 inch or 25mmMaximum length of IF in 8% of weld: 22.3672 mmMaximum length of indications of IF in any continuous 12" length of weld: N/A since total weld is under 12 inches.

INCOMPLETE FUSION DUE TO COLD LAPMaximum length of individual indications of IFD: 2 inches or 50mmMaximum length of IFD in 8% of weld: 22.3672 mmMaximum length of indications of IFD in any continuous 12" length of weld: N/A since total weld is under 12 inches.

INTERNAL CONCAVITY Any length of IC is acceptable, provided the density of the radiographic image of the internal concavity does not exceed that of the thinnest adjacent parent material. For areas that exceed the density of thethinnest adjacent parent material, the criteria for burn through are applicable.

BURN - THROUGHMaximum dimension of BT's image : unacceptable if it exceeds that of the thinnest adjacent parent metal.Maximum dimension of BT: 1/4" or 6mmMaximum dimension is unacceptable if: it exceeds the thinner of the nonnal wall thickness joined, and the density

of the BT's image exceeds that of the thinnest adjacent parent material.The sum of the max dimensions of separate BBT's whose image density exceeds that of the thinnest adjacent parentmaterial exceeds 1/2 inch or 13mm in any continuous 12" length of weld or the total weld length(whichever is less).

API - 11043" s/10 - 0.120" Wall

Page 1 of 2

Page 13: NDT Code Book Made Easy

API - 11043" s/10 - 0.120" Wall

SLAG INCLUSIONSElongated slag inclusions (ESI)Maximum length of an ESI: 2 inches or 50mmParallel ESI indications (Wagon Tracks) shall be considered a single indication unless the width of either of them exceed1/32" or 0.8mm. In that event they shall be considered separate indications.Maximum length of ESI indications in any continuous 12" length of weld: N/A since total weld is under 12 inches.Maximum width of an individual ESI indication: 1/16" or 1.6mmIsolated slag inclusions (ISI)Maximum length of ISI indications in any continuous 12" length of weld: N/A since total weld is under 12 inches.Maximum width of an ISI indication: 1/8" or 3mmMaximum length of ESI and ISI in 8% of weld: 22.3672 mm

POROSITY Individual or Scattered Porosity.Maximum size of an individual pore: 1/8" or 3mmThe size of an individual pore exceeds 25% of the thinner of the nonimal wall thickness joined.The distribution of scattered porosity exceeds the concentration permitted in Figures 19 or 20.Cluster Porosity (CP)Maximum diameter of the cluster: 1/2 inch or 13mmMaximum length of CP indications in any continuous 12" length of weweld: N/A since total weld is under 12 inches.Maximum length of an individual pore within a cluster: 1/16 inch or 2mmHollow Bead Porosity (HB)Maximum length of an individual indication of HB: 1/2 inch or 13mmMaximum length of HB indications in any continuous 12" length of weld: N/A since total weld is under 12 inches.Maximum length of HB in 8% of weld: 22.3672 mmNOTE: The weld is unacceptable if individual indications of HB, each greater than 1/4 inch or 6mm in length, are seperated by less than 2 inches or 50 mm.

CRACKSNote: Any crack which is not a shallow crater crack or star crack is unacceptable.Maximum length of shallow crater cracks or star cracks: 5/32 inch or 4mm

UNDERCUTTINGUndercutting adjacent to the cover pass (EU) and Undercutting adjacent to the root pass (IU)Maximum length of EU and IU indications (in any combination) in a 12 inch length of weld: N/AMaximum length of EU and IU indications: 1.835" 46.6090 mm (This value is 1/6 th of the total weld length)

ACCUMULATION OF IMPERFECTIONSMaximum length of AI indications in any continuous 12 inch or 300 mm length of weld: N/AMaximum length of AI indications of 8% of weld: 22.3672 mm

RADIOGRAPHIC INFOPipe O.D. in inches: 3.5"Amount of Penetrameters required for each shot: 1 penny in the center of the weldTotal weld length: 11.0075 279.5905 mmCassette size to complete weld in most efficient way: 3.5 x 10" 4.5 x 10"Amount of shots to complete weld with 1" on each side of readable film: 38% of weld: 0.8806 22.3672 mmHole penetrameters are adjacent to the weld and Wire penetrameters are parallel to the weld.

Page 2 of 2

Page 14: NDT Code Book Made Easy

PENETRAMETER SELECTIONNote: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Wire: 0.008 Esn. Wire: A2 S/S Hole: 12

F/S Wire: 0.006 Esn. Wire: A3 F/S Hole: 10Welds with reinforcement: S/S Wire: 0.010 Esn. Wire: A1 or B6 S/S Hole: 15

F/S Wire: 0.008 Esn. Wire: A2 F/S Hole: 12Maximum allowable reinforcement: 0.0625"/per sideMaximum reinforcement with DWE/SWV: 0.125" Total of walls + reinforcement: 0.557" 14.1478 mmMaximum reinforcement with DWE/DWV: 0.125" Total of walls + reinforcement: 0.557" 14.1478 mmMaximum reinforcement with SWE/SWV: 0.0625" Total of wall + reinforcement: 0.279" 7.0866 mm

INADEQUATE PENETRATION WITHOUT HIGH LOWMaximum length of individual indication of IP : 1 inch or 25mmMaximum length of IP in 8% of weld: 22.3672 mmMaximum length of indications in any continuous 12" length of weld: N/A since total weld is under 12 inches

INADEQUATE PENETRATION DUE TO HIGH LOWMaximum length of individual indication of IPD: 2 inches or 50mmMaximum length of indications of IPD in any continuous 12" length of weld: N/A since total weld is under 12 inches.

INADEQUATE CROSS PENETRATIONMaximum length of an individual indication of ICP: 2 inches or 50mmMaximum length of indications of ICP in any continuous 12" length of weld: N/A since total weld is under 12 inches.

INCOMPLETE FUSIONMaximum length of an individual indication of IF: 1 inch or 25mmMaximum length of IF in 8% of weld: 22.3672 mmMaximum length of indications of IF in any continuous 12" length of weld: N/A since total weld is under 12 inches.

INCOMPLETE FUSION DUE TO COLD LAPMaximum length of individual indications of IFD: 2 inches or 50mmMaximum length of IFD in 8% of weld: 22.3672 mmMaximum length of indications of IFD in any continuous 12" length of weld: N/A since total weld is under 12 inches.

INTERNAL CONCAVITY Any length of IC is acceptable, provided the density of the radiographic image of the internal concavity does not exceed that of the thinnest adjacent parent material. For areas that exceed the density of thethinnest adjacent parent material, the criteria for burn through are applicable.

BURN - THROUGHMaximum dimension of BT's image : unacceptable if it exceeds that of the thinnest adjacent parent metal.Maximum dimension of BT: 1/4" or 6mmMaximum dimension is unacceptable if: it exceeds the thinner of the nonnal wall thickness joined, and the density

of the BT's image exceeds that of the thinnest adjacent parent material.The sum of the max dimensions of separate BBT's whose image density exceeds that of the thinnest adjacent parentmaterial exceeds 1/2 inch or 13mm in any continuous 12" length of weld or the total weld length(whichever is less).

API - 11043" s/40 & Std. - 0.216" Wall

Page 1 of 2

Page 15: NDT Code Book Made Easy

API - 11043" s/40 & Std. - 0.216" Wall

SLAG INCLUSIONSElongated slag inclusions (ESI)Maximum length of an ESI: 2 inches or 50mmParallel ESI indications (Wagon Tracks) shall be considered a single indication unless the width of either of them exceed1/32" or 0.8mm. In that event they shall be considered separate indications.Maximum length of ESI indications in any continuous 12" length of weld: N/A since total weld is under 12 inches.Maximum width of an individual ESI indication: 1/16" or 1.6mmIsolated slag inclusions (ISI)Maximum length of ISI indications in any continuous 12" length of weld: N/A since total weld is under 12 inches.Maximum width of an ISI indication: 1/8" or 3mmMaximum length of ESI and ISI in 8% of weld: 22.3672 mm

POROSITY Individual or Scattered Porosity.Maximum size of an individual pore: 1/8" or 3mmThe size of an individual pore exceeds 25% of the thinner of the nonimal wall thickness joined.The distribution of scattered porosity exceeds the concentration permitted in Figures 19 or 20.Cluster Porosity (CP)Maximum diameter of the cluster: 1/2 inch or 13mmMaximum length of CP indications in any continuous 12" length of weweld: N/A since total weld is under 12 inches.Maximum length of an individual pore within a cluster: 1/16 inch or 2mmHollow Bead Porosity (HB)Maximum length of an individual indication of HB: 1/2 inch or 13mmMaximum length of HB indications in any continuous 12" length of weld: N/A since total weld is under 12 inches.Maximum length of HB in 8% of weld: 22.3672 mmNOTE: The weld is unacceptable if individual indications of HB, each greater than 1/4 inch or 6mm in length, are seperated by less than 2 inches or 50 mm.

CRACKSNote: Any crack which is not a shallow crater crack or star crack is unacceptable.Maximum length of shallow crater cracks or star cracks: 5/32 inch or 4mm

UNDERCUTTINGUndercutting adjacent to the cover pass (EU) and Undercutting adjacent to the root pass (IU)Maximum length of EU and IU indications (in any combination) in a 12 inch length of weld: N/AMaximum length of EU and IU indications: 1.835" 46.6090 mm (This value is 1/6 th of the total weld length)

ACCUMULATION OF IMPERFECTIONSMaximum length of AI indications in any continuous 12 inch or 300 mm length of weld: N/AMaximum length of AI indications of 8% of weld: 22.3672 mm

RADIOGRAPHIC INFOPipe O.D. in inches: 3.5"Amount of Penetrameters required for each shot: 1 penny in the center of the weldTotal weld length: 11.0075 279.5905 mmCassette size to complete weld in most efficient way: 3.5 x 10" 4.5 x 10"Amount of shots to complete weld with 1" on each side of readable film: 38% of weld: 0.8806 22.3672 mmHole penetrameters are adjacent to the weld and Wire penetrameters are parallel to the weld.

Page 2 of 2

Page 16: NDT Code Book Made Easy

PENETRAMETER SELECTIONNote: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Wire: 0.010 Esn. Wire: A1 or B6 S/S Hole: 15

F/S Wire: 0.008 Esn. Wire: A2 F/S Hole: 12Welds with reinforcement: S/S Wire: 0.013 Esn. Wire: B5 S/S Hole: 17

F/S Wire: 0.010 Esn. Wire: A1 or B6 F/S Hole: 15Maximum allowable reinforcement: 0.0625"/per sideMaximum reinforcement with DWE/SWV: 0.125" Total of walls + reinforcement: 0.725" 18.4150 mmMaximum reinforcement with DWE/DWV: 0.125" Total of walls + reinforcement: 0.725" 18.4150 mmMaximum reinforcement with SWE/SWV: 0.0625" Total of wall + reinforcement: 0.363" 9.2202 mm

INADEQUATE PENETRATION WITHOUT HIGH LOWMaximum length of individual indication of IP : 1 inch or 25mmMaximum length of IP in 8% of weld: 22.3672 mmMaximum length of indications in any continuous 12" length of weld: N/A since total weld is under 12 inches

INADEQUATE PENETRATION DUE TO HIGH LOWMaximum length of individual indication of IPD: 2 inches or 50mmMaximum length of indications of IPD in any continuous 12" length of weld: N/A since total weld is under 12 inches.

INADEQUATE CROSS PENETRATIONMaximum length of an individual indication of ICP: 2 inches or 50mmMaximum length of indications of ICP in any continuous 12" length of weld: N/A since total weld is under 12 inches.

INCOMPLETE FUSIONMaximum length of an individual indication of IF: 1 inch or 25mmMaximum length of IF in 8% of weld: 22.3672 mmMaximum length of indications of IF in any continuous 12" length of weld: N/A since total weld is under 12 inches.

INCOMPLETE FUSION DUE TO COLD LAPMaximum length of individual indications of IFD: 2 inches or 50mmMaximum length of IFD in 8% of weld: 22.3672 mmMaximum length of indications of IFD in any continuous 12" length of weld: N/A since total weld is under 12 inches.

INTERNAL CONCAVITY Any length of IC is acceptable, provided the density of the radiographic image of the internal concavity does not exceed that of the thinnest adjacent parent material. For areas that exceed the density of thethinnest adjacent parent material, the criteria for burn through are applicable.

BURN - THROUGHMaximum dimension of BT's image : unacceptable if it exceeds that of the thinnest adjacent parent metal.Maximum dimension of BT: 1/4" or 6mmMaximum dimension is unacceptable if: it exceeds the thinner of the nonnal wall thickness joined, and the density

of the BT's image exceeds that of the thinnest adjacent parent material.The sum of the max dimensions of separate BBT's whose image density exceeds that of the thinnest adjacent parentmaterial exceeds 1/2 inch or 13mm in any continuous 12" length of weld or the total weld length(whichever is less).

API - 11043" s/80 and Extra Strong - 0.300" Wall

Page 1 of 2

Page 17: NDT Code Book Made Easy

API - 11043" s/80 and Extra Strong - 0.300" Wall

SLAG INCLUSIONSElongated slag inclusions (ESI)Maximum length of an ESI: 2 inches or 50mmParallel ESI indications (Wagon Tracks) shall be considered a single indication unless the width of either of them exceed1/32" or 0.8mm. In that event they shall be considered separate indications.Maximum length of ESI indications in any continuous 12" length of weld: N/A since total weld is under 12 inches.Maximum width of an individual ESI indication: 1/16" or 1.6mmIsolated slag inclusions (ISI)Maximum length of ISI indications in any continuous 12" length of weld: N/A since total weld is under 12 inches.Maximum width of an ISI indication: 1/8" or 3mmMaximum length of ESI and ISI in 8% of weld: 22.3672 mm

POROSITY Individual or Scattered Porosity.Maximum size of an individual pore: 1/8" or 3mmThe size of an individual pore exceeds 25% of the thinner of the nonimal wall thickness joined.The distribution of scattered porosity exceeds the concentration permitted in Figures 19 or 20.Cluster Porosity (CP)Maximum diameter of the cluster: 1/2 inch or 13mmMaximum length of CP indications in any continuous 12" length of weweld: N/A since total weld is under 12 inches.Maximum length of an individual pore within a cluster: 1/16 inch or 2mmHollow Bead Porosity (HB)Maximum length of an individual indication of HB: 1/2 inch or 13mmMaximum length of HB indications in any continuous 12" length of weld: N/A since total weld is under 12 inches.Maximum length of HB in 8% of weld: 22.3672 mmNOTE: The weld is unacceptable if individual indications of HB, each greater than 1/4 inch or 6mm in length, are seperated by less than 2 inches or 50 mm.

CRACKSNote: Any crack which is not a shallow crater crack or star crack is unacceptable.Maximum length of shallow crater cracks or star cracks: 5/32 inch or 4mm

UNDERCUTTINGUndercutting adjacent to the cover pass (EU) and Undercutting adjacent to the root pass (IU)Maximum length of EU and IU indications (in any combination) in a 12 inch length of weld: N/AMaximum length of EU and IU indications: 1.835" 46.6090 mm (This value is 1/6 th of the total weld length)

ACCUMULATION OF IMPERFECTIONSMaximum length of AI indications in any continuous 12 inch or 300 mm length of weld: N/AMaximum length of AI indications of 8% of weld: 22.3672 mm

RADIOGRAPHIC INFOPipe O.D. in inches: 3.5"Amount of Penetrameters required for each shot: 1 penny in the center of the weldTotal weld length: 11.0075 279.5905 mmCassette size to complete weld in most efficient way: 3.5 x 10" 4.5 x 10"Amount of shots to complete weld with 1" on each side of readable film: 38% of weld: 0.8806 22.3672 mmHole penetrameters are adjacent to the weld and Wire penetrameters are parallel to the weld.

Page 2 of 2

Page 18: NDT Code Book Made Easy

PENETRAMETER SELECTIONNote: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Wire: 0.013 Esn. Wire: B5 S/S Hole: 17

F/S Wire: 0.010 Esn. Wire: A1 or B6 F/S Hole: 15Welds with reinforcement: S/S Wire: 0.016 Esn. Wire: B4 S/S Hole: 20

F/S Wire: 0.013 Esn. Wire: B5 F/S Hole: 17Maximum allowable reinforcement: 0.0625"/per sideMaximum reinforcement with DWE/SWV: 0.125" Total of walls + reinforcement: 1.001" 25.4254 mmMaximum reinforcement with DWE/DWV: 0.125" Total of walls + reinforcement: 1.001" 25.4254 mmMaximum reinforcement with SWE/SWV: 0.0625" Total of wall + reinforcement: 0.500" 12.7000 mm

INADEQUATE PENETRATION WITHOUT HIGH LOWMaximum length of individual indication of IP : 1 inch or 25mmMaximum length of IP in 8% of weld: 22.3672 mmMaximum length of indications in any continuous 12" length of weld: N/A since total weld is under 12 inches

INADEQUATE PENETRATION DUE TO HIGH LOWMaximum length of individual indication of IPD: 2 inches or 50mmMaximum length of indications of IPD in any continuous 12" length of weld: N/A since total weld is under 12 inches.

INADEQUATE CROSS PENETRATIONMaximum length of an individual indication of ICP: 2 inches or 50mmMaximum length of indications of ICP in any continuous 12" length of weld: N/A since total weld is under 12 inches.

INCOMPLETE FUSIONMaximum length of an individual indication of IF: 1 inch or 25mmMaximum length of IF in 8% of weld: 22.3672 mmMaximum length of indications of IF in any continuous 12" length of weld: N/A since total weld is under 12 inches.

INCOMPLETE FUSION DUE TO COLD LAPMaximum length of individual indications of IFD: 2 inches or 50mmMaximum length of IFD in 8% of weld: 22.3672 mmMaximum length of indications of IFD in any continuous 12" length of weld: N/A since total weld is under 12 inches.

INTERNAL CONCAVITY Any length of IC is acceptable, provided the density of the radiographic image of the internal concavity does not exceed that of the thinnest adjacent parent material. For areas that exceed the density of thethinnest adjacent parent material, the criteria for burn through are applicable.

BURN - THROUGHMaximum dimension of BT's image : unacceptable if it exceeds that of the thinnest adjacent parent metal.Maximum dimension of BT: 1/4" or 6mmMaximum dimension is unacceptable if: it exceeds the thinner of the nonnal wall thickness joined, and the density

of the BT's image exceeds that of the thinnest adjacent parent material.The sum of the max dimensions of separate BBT's whose image density exceeds that of the thinnest adjacent parentmaterial exceeds 1/2 inch or 13mm in any continuous 12" length of weld or the total weld length(whichever is less).

API - 11043" s/160 - 0.438" Wall

Page 1 of 2

Page 19: NDT Code Book Made Easy

API - 11043" s/160 - 0.438" Wall

SLAG INCLUSIONSElongated slag inclusions (ESI)Maximum length of an ESI: 2 inches or 50mmParallel ESI indications (Wagon Tracks) shall be considered a single indication unless the width of either of them exceed1/32" or 0.8mm. In that event they shall be considered separate indications.Maximum length of ESI indications in any continuous 12" length of weld: N/A since total weld is under 12 inches.Maximum width of an individual ESI indication: 1/16" or 1.6mmIsolated slag inclusions (ISI)Maximum length of ISI indications in any continuous 12" length of weld: N/A since total weld is under 12 inches.Maximum width of an ISI indication: 1/8" or 3mmMaximum length of ESI and ISI in 8% of weld: 22.3672 mm

POROSITY Individual or Scattered Porosity.Maximum size of an individual pore: 1/8" or 3mmThe size of an individual pore exceeds 25% of the thinner of the nonimal wall thickness joined.The distribution of scattered porosity exceeds the concentration permitted in Figures 19 or 20.Cluster Porosity (CP)Maximum diameter of the cluster: 1/2 inch or 13mmMaximum length of CP indications in any continuous 12" length of weweld: N/A since total weld is under 12 inches.Maximum length of an individual pore within a cluster: 1/16 inch or 2mmHollow Bead Porosity (HB)Maximum length of an individual indication of HB: 1/2 inch or 13mmMaximum length of HB indications in any continuous 12" length of weld: N/A since total weld is under 12 inches.Maximum length of HB in 8% of weld: 22.3672 mmNOTE: The weld is unacceptable if individual indications of HB, each greater than 1/4 inch or 6mm in length, are seperated by less than 2 inches or 50 mm.

CRACKSNote: Any crack which is not a shallow crater crack or star crack is unacceptable.Maximum length of shallow crater cracks or star cracks: 5/32 inch or 4mm

UNDERCUTTINGUndercutting adjacent to the cover pass (EU) and Undercutting adjacent to the root pass (IU)Maximum length of EU and IU indications (in any combination) in a 12 inch length of weld: N/AMaximum length of EU and IU indications: 1.835" 46.6090 mm (This value is 1/6 th of the total weld length)

ACCUMULATION OF IMPERFECTIONSMaximum length of AI indications in any continuous 12 inch or 300 mm length of weld: N/AMaximum length of AI indications of 8% of weld: 22.3672 mm

RADIOGRAPHIC INFOPipe O.D. in inches: 3.5"Amount of Penetrameters required for each shot: 1 penny in the center of the weldTotal weld length: 11.0075 279.5905 mmCassette size to complete weld in most efficient way: 3.5 x 10" 4.5 x 10"Amount of shots to complete weld with 1" on each side of readable film: 48% of weld: 0.8806 22.3672 mmHole penetrameters are adjacent to the weld and Wire penetrameters are parallel to the weld.

Page 2 of 2

Page 20: NDT Code Book Made Easy

PENETRAMETER SELECTIONNote: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Wire: 0.016 Esn. Wire: B4 S/S Hole: 20

F/S Wire: 0.013 Esn. Wire: B5 F/S Hole: 17Welds with reinforcement: S/S Wire: 0.020 Esn. Wire: B3 S/S Hole: 25

F/S Wire: 0.016 Esn. Wire: B4 F/S Hole: 20Maximum allowable reinforcement: 0.0625"/per sideMaximum reinforcement with DWE/SWV: 0.125" Total of walls + reinforcement: 1.325" 33.6550 mmMaximum reinforcement with DWE/DWV: 0.125" Total of walls + reinforcement: 1.325" 33.6550 mmMaximum reinforcement with SWE/SWV: 0.0625" Total of wall + reinforcement: 0.663" 16.8402 mm

INADEQUATE PENETRATION WITHOUT HIGH LOWMaximum length of individual indication of IP : 1 inch or 25mmMaximum length of IP in 8% of weld: 22.3672 mmMaximum length of indications in any continuous 12" length of weld: N/A since total weld is under 12 inches

INADEQUATE PENETRATION DUE TO HIGH LOWMaximum length of individual indication of IPD: 2 inches or 50mmMaximum length of indications of IPD in any continuous 12" length of weld: N/A since total weld is under 12 inches.

INADEQUATE CROSS PENETRATIONMaximum length of an individual indication of ICP: 2 inches or 50mmMaximum length of indications of ICP in any continuous 12" length of weld: N/A since total weld is under 12 inches.

INCOMPLETE FUSIONMaximum length of an individual indication of IF: 1 inch or 25mmMaximum length of IF in 8% of weld: 22.3672 mmMaximum length of indications of IF in any continuous 12" length of weld: N/A since total weld is under 12 inches.

INCOMPLETE FUSION DUE TO COLD LAPMaximum length of individual indications of IFD: 2 inches or 50mmMaximum length of IFD in 8% of weld: 22.3672 mmMaximum length of indications of IFD in any continuous 12" length of weld: N/A since total weld is under 12 inches.

INTERNAL CONCAVITY Any length of IC is acceptable, provided the density of the radiographic image of the internal concavity does not exceed that of the thinnest adjacent parent material. For areas that exceed the density of thethinnest adjacent parent material, the criteria for burn through are applicable.

BURN - THROUGHMaximum dimension of BT's image : unacceptable if it exceeds that of the thinnest adjacent parent metal.Maximum dimension of BT: 1/4" or 6mmMaximum dimension is unacceptable if: it exceeds the thinner of the nonnal wall thickness joined, and the density

of the BT's image exceeds that of the thinnest adjacent parent material.The sum of the max dimensions of separate BBT's whose image density exceeds that of the thinnest adjacent parentmaterial exceeds 1/2 inch or 13mm in any continuous 12" length of weld or the total weld length(whichever is less).

API - 11043" XX Strong - 0.600" Wall

Page 1 of 2

Page 21: NDT Code Book Made Easy

API - 11043" XX Strong - 0.600" Wall

SLAG INCLUSIONSElongated slag inclusions (ESI)Maximum length of an ESI: 2 inches or 50mmParallel ESI indications (Wagon Tracks) shall be considered a single indication unless the width of either of them exceed1/32" or 0.8mm. In that event they shall be considered separate indications.Maximum length of ESI indications in any continuous 12" length of weld: N/A since total weld is under 12 inches.Maximum width of an individual ESI indication: 1/16" or 1.6mmIsolated slag inclusions (ISI)Maximum length of ISI indications in any continuous 12" length of weld: N/A since total weld is under 12 inches.Maximum width of an ISI indication: 1/8" or 3mmMaximum length of ESI and ISI in 8% of weld: 22.3672 mm

POROSITY Individual or Scattered Porosity.Maximum size of an individual pore: 1/8" or 3mmThe size of an individual pore exceeds 25% of the thinner of the nonimal wall thickness joined.The distribution of scattered porosity exceeds the concentration permitted in Figures 19 or 20.Cluster Porosity (CP)Maximum diameter of the cluster: 1/2 inch or 13mmMaximum length of CP indications in any continuous 12" length of weweld: N/A since total weld is under 12 inches.Maximum length of an individual pore within a cluster: 1/16 inch or 2mmHollow Bead Porosity (HB)Maximum length of an individual indication of HB: 1/2 inch or 13mmMaximum length of HB indications in any continuous 12" length of weld: N/A since total weld is under 12 inches.Maximum length of HB in 8% of weld: 22.3672 mmNOTE: The weld is unacceptable if individual indications of HB, each greater than 1/4 inch or 6mm in length, are seperated by less than 2 inches or 50 mm.

CRACKSNote: Any crack which is not a shallow crater crack or star crack is unacceptable.Maximum length of shallow crater cracks or star cracks: 5/32 inch or 4mm

UNDERCUTTINGUndercutting adjacent to the cover pass (EU) and Undercutting adjacent to the root pass (IU)Maximum length of EU and IU indications (in any combination) in a 12 inch length of weld: N/AMaximum length of EU and IU indications: 1.835" 46.6090 mm (This value is 1/6 th of the total weld length)

ACCUMULATION OF IMPERFECTIONSMaximum length of AI indications in any continuous 12 inch or 300 mm length of weld: N/AMaximum length of AI indications of 8% of weld: 22.3672 mm

RADIOGRAPHIC INFOPipe O.D. in inches: 3.5"Amount of Penetrameters required for each shot: 1 penny in the center of the weldTotal weld length: 11.0075 279.5905 mmCassette size to complete weld in most efficient way: 3.5 x 10" 4.5 x 10"Amount of shots to complete weld with 1" on each side of readable film: 58% of weld: 0.8806 22.3672 mmHole penetrameters are adjacent to the weld and Wire penetrameters are parallel to the weld.

Page 2 of 2

Page 22: NDT Code Book Made Easy

PENETRAMETER SELECTIONNote: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Wire: 0.008 Esn. Wire: A2 S/S Hole: 12

F/S Wire: 0.006 Esn. Wire: A3 F/S Hole: 10Welds with reinforcement: S/S Wire: 0.008 Esn. Wire: A2 S/S Hole: 12

F/S Wire: 0.006 Esn. Wire: A3 F/S Hole: 10Maximum allowable reinforcement: 0.0625"/per sideMaximum reinforcement with DWE/SWV: 0.125" Total of walls + reinforcement: 0.365" 9.2710 mmMaximum reinforcement with DWE/DWV: 0.125" Total of walls + reinforcement: 0.365" 9.2710 mmMaximum reinforcement with SWE/SWV: 0.0625" Total of wall + reinforcement: 0.183" 4.6482 mm

INADEQUATE PENETRATION WITHOUT HIGH LOWMaximum length of individual indication of IP : 1 inch or 25mmMaximum length of IP in 8% of weld: N/A since total weld exceeds 12 inchesMaximum length of indications in any continuous 12" length of weld: 1" 25 mm

INADEQUATE PENETRATION DUE TO HIGH LOWMaximum length of individual indication of IPD: 2 inches or 50mmMaximum length of indications of IPD in any continuous 12" length of weld: 3" 75 mm

INADEQUATE CROSS PENETRATIONMaximum length of an individual indication of ICP: 2 inches or 50mmMaximum length of indications of ICP in any continuous 12" length of weld: 2" 50 mm

INCOMPLETE FUSIONMaximum length of an individual indication of IF: 1 inch or 25mmMaximum length of IF in 8% of weld: N/A since total weld exceeds 12 inchesMaximum length of indications of IF in any continuous 12" length of weld: 1" 25 mm

INCOMPLETE FUSION DUE TO COLD LAPMaximum length of individual indications of IFD: 2 inches or 50mmMaximum length of IFD in 8% of weld: 28.7579 mmMaximum length of indications of IFD in any continuous 12" length of weld: 2" 25 mm

INTERNAL CONCAVITY Any length of IC is acceptable, provided the density of the radiographic image of the internal concavity does not exceed that of the thinnest adjacent parent material. For areas that exceed the density of thethinnest adjacent parent material, the criteria for burn through are applicable.

BURN - THROUGHMaximum dimension of BT's image : unacceptable if it exceeds that of the thinnest adjacent parent metal.Maximum dimension of BT: 1/4" or 6mmMaximum dimension is unacceptable if: it exceeds the thinner of the nonnal wall thickness joined, and the density

of the BT's image exceeds that of the thinnest adjacent parent material.The sum of the max dimensions of separate BBT's whose image density exceeds that of the thinnest adjacent parentmaterial exceeds 1/2 inch or 13mm in any continuous 12" length of weld or the total weld length(whichever is less).

API - 11044" s/10 - 0.120" Wall

Page 1 of 2

Page 23: NDT Code Book Made Easy

API - 11044" s/10 - 0.120" Wall

SLAG INCLUSIONSElongated slag inclusions (ESI)Maximum length of an ESI: 2 inches or 50mmParallel ESI indications (Wagon Tracks) shall be considered a single indication unless the width of either of them exceed1/32" or 0.8mm. In that event they shall be considered separate indications.Maximum length of ESI indications in any continuous 12" length of weld: 2" 50 mmMaximum width of an individual ESI indication: 1/16" or 1.6mmIsolated slag inclusions (ISI)Maximum length of ISI indications in any continuous 12" length of weld: 1/2" 13 mmMaximum width of an ISI indication: 1/8" or 3mmMaximum length of ESI and ISI in 8% of weld: 28.7579 mm

POROSITY Individual or Scattered Porosity.Maximum size of an individual pore: 1/8" or 3mmThe size of an individual pore exceeds 25% of the thinner of the nonimal wall thickness joined.The distribution of scattered porosity exceeds the concentration permitted in Figures 19 or 20.Cluster Porosity (CP)Maximum diameter of the cluster: 1/2 inch or 13mmMaximum length of CP indications in any continuous 12" length of weweld: 1/2" 13 mmMaximum length of an individual pore within a cluster: 1/16 inch or 2mmHollow Bead Porosity (HB)Maximum length of an individual indication of HB: 1/2 inch or 13mmMaximum length of HB indications in any continuous 12" length of weld: 2" 50 mmMaximum length of HB in 8% of weld: 28.7579 mmNOTE: The weld is unacceptable if individual indications of HB, each greater than 1/4 inch or 6mm in length, are seperated by less than 2 inches or 50 mm.

CRACKSNote: Any crack which is not a shallow crater crack or star crack is unacceptable.Maximum length of shallow crater cracks or star cracks: 5/32 inch or 4mm

UNDERCUTTINGUndercutting adjacent to the cover pass (EU) and Undercutting adjacent to the root pass (IU)Maximum length of EU and IU indications (in any combination) in a 12 inch length of weld: 2" 50 mmMaximum length of EU and IU indications: 2.35875" 59.9123 mm (This value is 1/6 th of the total weld length)

ACCUMULATION OF IMPERFECTIONSMaximum length of AI indications in any continuous 12 inch or 300 mm length of weld: 2" 50 mmMaximum length of AI indications of 8% of weld: 28.7579 mm

RADIOGRAPHIC INFOPipe O.D. in inches: 4.5"Amount of Penetrameters required for each shot: 1 penny in the center of the weldTotal weld length: 14.1525" 359.4735 mmCassette size to complete weld in most efficient way: 3.5 x 10" 4.5 x 10"Amount of shots to complete weld with 1" on each side of readable film: 38% of weld: 1.1322" 28.7579 mmHole penetrameters are adjacent to the weld and Wire penetrameters are parallel to the weld.

Page 2 of 2

Page 24: NDT Code Book Made Easy

PENETRAMETER SELECTIONNote: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Wire: 0.008 Esn. Wire: A2 S/S Hole: 12

F/S Wire: 0.006 Esn. Wire: A3 F/S Hole: 10Welds with reinforcement: S/S Wire: 0.010 Esn. Wire: A1 or B6 S/S Hole: 15

F/S Wire: 0.008 Esn. Wire: A2 F/S Hole: 12Maximum allowable reinforcement: 0.0625"/per sideMaximum reinforcement with DWE/SWV: 0.125" Total of walls + reinforcement: .599" 15.2146 mmMaximum reinforcement with DWE/DWV: 0.125" Total of walls + reinforcement: .599" 15.2146 mmMaximum reinforcement with SWE/SWV: 0.0625" Total of wall + reinforcement: .300" 7.6200 mm

INADEQUATE PENETRATION WITHOUT HIGH LOWMaximum length of individual indication of IP : 1 inch or 25mmMaximum length of IP in 8% of weld: N/A since total weld exceeds 12 inchesMaximum length of indications in any continuous 12" length of weld: 1" 25 mm

INADEQUATE PENETRATION DUE TO HIGH LOWMaximum length of individual indication of IPD: 2 inches or 50mmMaximum length of indications of IPD in any continuous 12" length of weld: 3" 75 mm

INADEQUATE CROSS PENETRATIONMaximum length of an individual indication of ICP: 2 inches or 50mmMaximum length of indications of ICP in any continuous 12" length of weld: 2" 50 mm

INCOMPLETE FUSIONMaximum length of an individual indication of IF: 1 inch or 25mmMaximum length of IF in 8% of weld: N/A since total weld exceeds 12 inches Maximum length of indications of IF in any continuous 12" length of weld: 1" 25 mm

INCOMPLETE FUSION DUE TO COLD LAPMaximum length of individual indications of IFD: 2 inches or 50mmMaximum length of IFD in 8% of weld: 28.7579 mmMaximum length of indications of IFD in any continuous 12" length of weld: 2" 25 mm

INTERNAL CONCAVITY Any length of IC is acceptable, provided the density of the radiographic image of the internal concavity does not exceed that of the thinnest adjacent parent material. For areas that exceed the density of thethinnest adjacent parent material, the criteria for burn through are applicable.

BURN - THROUGHMaximum dimension of BT's image : unacceptable if it exceeds that of the thinnest adjacent parent metal.Maximum dimension of BT: 1/4" or 6mmMaximum dimension is unacceptable if: it exceeds the thinner of the nonnal wall thickness joined, and the density

of the BT's image exceeds that of the thinnest adjacent parent material.The sum of the max dimensions of separate BBT's whose image density exceeds that of the thinnest adjacent parentmaterial exceeds 1/2 inch or 13mm in any continuous 12" length of weld or the total weld length(whichever is less).

API - 11044" s/40 & Std. - 0.237" Wall

Page 1 of 2

Page 25: NDT Code Book Made Easy

API - 11044" s/40 & Std. - 0.237" Wall

SLAG INCLUSIONSElongated slag inclusions (ESI)Maximum length of an ESI: 2 inches or 50mmParallel ESI indications (Wagon Tracks) shall be considered a single indication unless the width of either of them exceed1/32" or 0.8mm. In that event they shall be considered separate indications.Maximum length of ESI indications in any continuous 12" length of weld: 2" 50 mmMaximum width of an individual ESI indication: 1/16" or 1.6mmIsolated slag inclusions (ISI)Maximum length of ISI indications in any continuous 12" length of weld: 1/2" 13 mmMaximum width of an ISI indication: 1/8" or 3mmMaximum length of ESI and ISI in 8% of weld: 28.7579 mm

POROSITY Individual or Scattered Porosity.Maximum size of an individual pore: 1/8" or 3mmThe size of an individual pore exceeds 25% of the thinner of the nonimal wall thickness joined.The distribution of scattered porosity exceeds the concentration permitted in Figures 19 or 20.Cluster Porosity (CP)Maximum diameter of the cluster: 1/2 inch or 13mmMaximum length of CP indications in any continuous 12" length of weweld: 1/2" 13 mmMaximum length of an individual pore within a cluster: 1/16 inch or 2mmHollow Bead Porosity (HB)Maximum length of an individual indication of HB: 1/2 inch or 13mmMaximum length of HB indications in any continuous 12" length of weld: 2" 50 mmMaximum length of HB in 8% of weld: 28.7579 mmNOTE: The weld is unacceptable if individual indications of HB, each greater than 1/4 inch or 6mm in length, are seperated by less than 2 inches or 50 mm.

CRACKSNote: Any crack which is not a shallow crater crack or star crack is unacceptable.Maximum length of shallow crater cracks or star cracks: 5/32 inch or 4mm

UNDERCUTTINGUndercutting adjacent to the cover pass (EU) and Undercutting adjacent to the root pass (IU)Maximum length of EU and IU indications (in any combination) in a 12 inch length of weld: 2" 50 mmMaximum length of EU and IU indications: 2.35875" 59.9123 mm (This value is 1/6 th of the total weld length)

ACCUMULATION OF IMPERFECTIONSMaximum length of AI indications in any continuous 12 inch or 300 mm length of weld: 2" 50 mmMaximum length of AI indications of 8% of weld: 28.7579 mm

RADIOGRAPHIC INFOPipe O.D. in inches: 4.5"Amount of Penetrameters required for each shot: 1 penny in the center of the weldTotal weld length: 14.1525" 359.4735 mmCassette size to complete weld in most efficient way: 3.5 x 10" 4.5 x 10"Amount of shots to complete weld with 1" on each side of readable film: 38% of weld: 1.1322" 28.7579 mmHole penetrameters are adjacent to the weld and Wire penetrameters are parallel to the weld.

Page 2 of 2

Page 26: NDT Code Book Made Easy

PENETRAMETER SELECTIONNote: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Wire: 0.010 Esn. Wire: A1 or B6 S/S Hole: 15

F/S Wire: 0.008 Esn. Wire: A2 F/S Hole: 12Welds with reinforcement: S/S Wire: 0.013 Esn. Wire: B5 S/S Hole: 17

F/S Wire: 0.010 Esn. Wire: A1 or B6 F/S Hole: 15Maximum allowable reinforcement: 0.0625"/per sideMaximum reinforcement with DWE/SWV: 0.125" Total of walls + reinforcement: 0.799" 20.2946 mmMaximum reinforcement with DWE/DWV: 0.125" Total of walls + reinforcement: 0.799" 20.2946 mmMaximum reinforcement with SWE/SWV: 0.0625" Total of wall + reinforcement: 0.400" 10.1600 mm

INADEQUATE PENETRATION WITHOUT HIGH LOWMaximum length of individual indication of IP : 1 inch or 25mmMaximum length of IP in 8% of weld: N/A since total weld exceeds 12 inchesMaximum length of indications in any continuous 12" length of weld: 1" 25 mm

INADEQUATE PENETRATION DUE TO HIGH LOWMaximum length of individual indication of IPD: 2 inches or 50mmMaximum length of indications of IPD in any continuous 12" length of weld: 3" 75 mm

INADEQUATE CROSS PENETRATIONMaximum length of an individual indication of ICP: 2 inches or 50mmMaximum length of indications of ICP in any continuous 12" length of weld: 2" 50 mm

INCOMPLETE FUSIONMaximum length of an individual indication of IF: 1 inch or 25mmMaximum length of IF in 8% of weld: N/A since total weld exceeds 12 inchesMaximum length of indications of IF in any continuous 12" length of weld: 1" 25 mm

INCOMPLETE FUSION DUE TO COLD LAPMaximum length of individual indications of IFD: 2 inches or 50mmMaximum length of IFD in 8% of weld: 28.7579 mmMaximum length of indications of IFD in any continuous 12" length of weld: 2" 25 mm

INTERNAL CONCAVITY Any length of IC is acceptable, provided the density of the radiographic image of the internal concavity does not exceed that of the thinnest adjacent parent material. For areas that exceed the density of thethinnest adjacent parent material, the criteria for burn through are applicable.

BURN - THROUGHMaximum dimension of BT's image : unacceptable if it exceeds that of the thinnest adjacent parent metal.Maximum dimension of BT: 1/4" or 6mmMaximum dimension is unacceptable if: it exceeds the thinner of the nonnal wall thickness joined, and the density

of the BT's image exceeds that of the thinnest adjacent parent material.The sum of the max dimensions of separate BBT's whose image density exceeds that of the thinnest adjacent parentmaterial exceeds 1/2 inch or 13mm in any continuous 12" length of weld or the total weld length(whichever is less).

API - 11044" s/80 and Extra Strong - 0.337" Wall

Page 1 of 2

Page 27: NDT Code Book Made Easy

API - 11044" s/80 and Extra Strong - 0.337" Wall

SLAG INCLUSIONSElongated slag inclusions (ESI)Maximum length of an ESI: 2 inches or 50mmParallel ESI indications (Wagon Tracks) shall be considered a single indication unless the width of either of them exceed1/32" or 0.8mm. In that event they shall be considered separate indications.Maximum length of ESI indications in any continuous 12" length of weld: 2" 50 mmMaximum width of an individual ESI indication: 1/16" or 1.6mmIsolated slag inclusions (ISI)Maximum length of ISI indications in any continuous 12" length of weld: 1/2" 13 mmMaximum width of an ISI indication: 1/8" or 3mmMaximum length of ESI and ISI in 8% of weld: 28.7579 mm

POROSITY Individual or Scattered Porosity.Maximum size of an individual pore: 1/8" or 3mmThe size of an individual pore exceeds 25% of the thinner of the nonimal wall thickness joined.The distribution of scattered porosity exceeds the concentration permitted in Figures 19 or 20.Cluster Porosity (CP)Maximum diameter of the cluster: 1/2 inch or 13mmMaximum length of CP indications in any continuous 12" length of weweld: 1/2" 13 mmMaximum length of an individual pore within a cluster: 1/16 inch or 2mmHollow Bead Porosity (HB)Maximum length of an individual indication of HB: 1/2 inch or 13mmMaximum length of HB indications in any continuous 12" length of weld: 2" 50 mmMaximum length of HB in 8% of weld: 28.7579 mmNOTE: The weld is unacceptable if individual indications of HB, each greater than 1/4 inch or 6mm in length, are seperated by less than 2 inches or 50 mm.

CRACKSNote: Any crack which is not a shallow crater crack or star crack is unacceptable.Maximum length of shallow crater cracks or star cracks: 5/32 inch or 4mm

UNDERCUTTINGUndercutting adjacent to the cover pass (EU) and Undercutting adjacent to the root pass (IU)Maximum length of EU and IU indications (in any combination) in a 12 inch length of weld: 2" 50 mmMaximum length of EU and IU indications: 2.35875" 59.9123 mm (This value is 1/6 th of the total weld length)

ACCUMULATION OF IMPERFECTIONSMaximum length of AI indications in any continuous 12 inch or 300 mm length of weld: 2" 50 mmMaximum length of AI indications of 8% of weld: 28.7579 mm

RADIOGRAPHIC INFOPipe O.D. in inches: 4.5"Amount of Penetrameters required for each shot: 1 penny in the center of the weldTotal weld length: 14.1525" 359.4735 mmCassette size to complete weld in most efficient way: 3.5 x 10" 4.5 x 10"Amount of shots to complete weld with 1" on each side of readable film: 38% of weld: 1.1322" 28.7579 mmHole penetrameters are adjacent to the weld and Wire penetrameters are parallel to the weld.

Page 2 of 2

Page 28: NDT Code Book Made Easy

PENETRAMETER SELECTIONNote: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Wire: 0.013 Esn. Wire: B5 S/S Hole: 17

F/S Wire: 0.010 Esn. Wire: A1 or B6 F/S Hole: 15Welds with reinforcement: S/S Wire: 0.016 Esn. Wire: B4 S/S Hole: 20

F/S Wire: 0.013 Esn. Wire: B5 F/S Hole: 17Maximum allowable reinforcement: 0.0625"/per sideMaximum reinforcement with DWE/SWV: 0.125" Total of walls + reinforcement: 1.001" 25.4254 mmMaximum reinforcement with DWE/DWV: 0.125" Total of walls + reinforcement: 1.001" 25.4254 mmMaximum reinforcement with SWE/SWV: 0.0625" Total of wall + reinforcement: 0.501" 12.7254 mm

INADEQUATE PENETRATION WITHOUT HIGH LOWMaximum length of individual indication of IP : 1 inch or 25mmMaximum length of IP in 8% of weld: N/A since total weld exceeds 12 inchesMaximum length of indications in any continuous 12" length of weld: 1" 25 mm

INADEQUATE PENETRATION DUE TO HIGH LOWMaximum length of individual indication of IPD: 2 inches or 50mmMaximum length of indications of IPD in any continuous 12" length of weld: 3" 75 mm

INADEQUATE CROSS PENETRATIONMaximum length of an individual indication of ICP: 2 inches or 50mmMaximum length of indications of ICP in any continuous 12" length of weld: 2" 50 mm

INCOMPLETE FUSIONMaximum length of an individual indication of IF: 1 inch or 25mmMaximum length of IF in 8% of weld: N/A since total weld exceeds 12 inchesMaximum length of indications of IF in any continuous 12" length of weld: 1" 25 mm

INCOMPLETE FUSION DUE TO COLD LAPMaximum length of individual indications of IFD: 2 inches or 50mmMaximum length of IFD in 8% of weld: 28.7579 mmMaximum length of indications of IFD in any continuous 12" length of weld: 2" 25 mm

INTERNAL CONCAVITY Any length of IC is acceptable, provided the density of the radiographic image of the internal concavity does not exceed that of the thinnest adjacent parent material. For areas that exceed the density of thethinnest adjacent parent material, the criteria for burn through are applicable.

BURN - THROUGHMaximum dimension of BT's image : unacceptable if it exceeds that of the thinnest adjacent parent metal.Maximum dimension of BT: 1/4" or 6mmMaximum dimension is unacceptable if: it exceeds the thinner of the nonnal wall thickness joined, and the density

of the BT's image exceeds that of the thinnest adjacent parent material.The sum of the max dimensions of separate BBT's whose image density exceeds that of the thinnest adjacent parentmaterial exceeds 1/2 inch or 13mm in any continuous 12" length of weld or the total weld length(whichever is less).

API - 11044" s/120 - 0.438" Wall

Page 1 of 2

Page 29: NDT Code Book Made Easy

API - 11044" s/120 - 0.438" Wall

SLAG INCLUSIONSElongated slag inclusions (ESI)Maximum length of an ESI: 2 inches or 50mmParallel ESI indications (Wagon Tracks) shall be considered a single indication unless the width of either of them exceed1/32" or 0.8mm. In that event they shall be considered separate indications.Maximum length of ESI indications in any continuous 12" length of weld: 2" 50 mmMaximum width of an individual ESI indication: 1/16" or 1.6mmIsolated slag inclusions (ISI)Maximum length of ISI indications in any continuous 12" length of weld: 1/2" 13 mmMaximum width of an ISI indication: 1/8" or 3mmMaximum length of ESI and ISI in 8% of weld: 28.7579 mm

POROSITY Individual or Scattered Porosity.Maximum size of an individual pore: 1/8" or 3mmThe size of an individual pore exceeds 25% of the thinner of the nonimal wall thickness joined.The distribution of scattered porosity exceeds the concentration permitted in Figures 19 or 20.Cluster Porosity (CP)Maximum diameter of the cluster: 1/2 inch or 13mmMaximum length of CP indications in any continuous 12" length of weweld: 1/2" 13 mmMaximum length of an individual pore within a cluster: 1/16 inch or 2mmHollow Bead Porosity (HB)Maximum length of an individual indication of HB: 1/2 inch or 13mmMaximum length of HB indications in any continuous 12" length of weld: 2" 50 mmMaximum length of HB in 8% of weld: 28.7579 mmNOTE: The weld is unacceptable if individual indications of HB, each greater than 1/4 inch or 6mm in length, are seperated by less than 2 inches or 50 mm.

CRACKSNote: Any crack which is not a shallow crater crack or star crack is unacceptable.Maximum length of shallow crater cracks or star cracks: 5/32 inch or 4mm

UNDERCUTTINGUndercutting adjacent to the cover pass (EU) and Undercutting adjacent to the root pass (IU)Maximum length of EU and IU indications (in any combination) in a 12 inch length of weld: 2" 50 mmMaximum length of EU and IU indications: 2.35875" 59.9123 mm (This value is 1/6 th of the total weld length)

ACCUMULATION OF IMPERFECTIONSMaximum length of AI indications in any continuous 12 inch or 300 mm length of weld: 2" 50 mmMaximum length of AI indications of 8% of weld: 28.7579 mm

RADIOGRAPHIC INFOPipe O.D. in inches: 4.5"Amount of Penetrameters required for each shot: 1 penny in the center of the weldTotal weld length: 14.1525" 359.4735 mmCassette size to complete weld in most efficient way: 3.5 x 10" 4.5 x 10"Amount of shots to complete weld with 1" on each side of readable film: 48% of weld: 1.1322" 28.7579 mmHole penetrameters are adjacent to the weld and Wire penetrameters are parallel to the weld.

Page 2 of 2

Page 30: NDT Code Book Made Easy

PENETRAMETER SELECTIONNote: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Wire: 0.016 Esn. Wire: B4 S/S Hole: 20

F/S Wire: 0.013 Esn. Wire: B5 F/S Hole: 17Welds with reinforcement: S/S Wire: 0.016 Esn. Wire: B4 S/S Hole: 20

F/S Wire: 0.013 Esn. Wire: B5 F/S Hole: 17Maximum allowable reinforcement: 0.0625"/per sideMaximum reinforcement with DWE/SWV: 0.125" Total of walls + reinforcement: 1.187" 30.1498 mmMaximum reinforcement with DWE/DWV: 0.125" Total of walls + reinforcement: 1.187" 30.1498 mmMaximum reinforcement with SWE/SWV: 0.0625" Total of wall + reinforcement: 0.594" 15.0876 mm

INADEQUATE PENETRATION WITHOUT HIGH LOWMaximum length of individual indication of IP : 1 inch or 25mmMaximum length of IP in 8% of weld: N/A since total weld exceeds 12 inchesMaximum length of indications in any continuous 12" length of weld: 1" 25 mm

INADEQUATE PENETRATION DUE TO HIGH LOWMaximum length of individual indication of IPD: 2 inches or 50mmMaximum length of indications of IPD in any continuous 12" length of weld: 3" 75 mm

INADEQUATE CROSS PENETRATIONMaximum length of an individual indication of ICP: 2 inches or 50mmMaximum length of indications of ICP in any continuous 12" length of weld: 2" 50 mm

INCOMPLETE FUSIONMaximum length of an individual indication of IF: 1 inch or 25mmMaximum length of IF in 8% of weld: N/A since total weld exceeds 12 inchesMaximum length of indications of IF in any continuous 12" length of weld: 1" 25 mm

INCOMPLETE FUSION DUE TO COLD LAPMaximum length of individual indications of IFD: 2 inches or 50mmMaximum length of IFD in 8% of weld: 28.7579 mmMaximum length of indications of IFD in any continuous 12" length of weld: 2" 25 mm

INTERNAL CONCAVITY Any length of IC is acceptable, provided the density of the radiographic image of the internal concavity does not exceed that of the thinnest adjacent parent material. For areas that exceed the density of thethinnest adjacent parent material, the criteria for burn through are applicable.

BURN - THROUGHMaximum dimension of BT's image : unacceptable if it exceeds that of the thinnest adjacent parent metal.Maximum dimension of BT: 1/4" or 6mmMaximum dimension is unacceptable if: it exceeds the thinner of the nonnal wall thickness joined, and the density

of the BT's image exceeds that of the thinnest adjacent parent material.The sum of the max dimensions of separate BBT's whose image density exceeds that of the thinnest adjacent parentmaterial exceeds 1/2 inch or 13mm in any continuous 12" length of weld or the total weld length(whichever is less).

API - 11044" s/160 - 0.531" Wall

Page 1 of 2

Page 31: NDT Code Book Made Easy

API - 11044" s/160 - 0.531" Wall

SLAG INCLUSIONSElongated slag inclusions (ESI)Maximum length of an ESI: 2 inches or 50mmParallel ESI indications (Wagon Tracks) shall be considered a single indication unless the width of either of them exceed1/32" or 0.8mm. In that event they shall be considered separate indications.Maximum length of ESI indications in any continuous 12" length of weld: 2" 50 mmMaximum width of an individual ESI indication: 1/16" or 1.6mmIsolated slag inclusions (ISI)Maximum length of ISI indications in any continuous 12" length of weld: 1/2" 13 mmMaximum width of an ISI indication: 1/8" or 3mmMaximum length of ESI and ISI in 8% of weld: 28.7579 mm

POROSITY Individual or Scattered Porosity.Maximum size of an individual pore: 1/8" or 3mmThe size of an individual pore exceeds 25% of the thinner of the nonimal wall thickness joined.The distribution of scattered porosity exceeds the concentration permitted in Figures 19 or 20.Cluster Porosity (CP)Maximum diameter of the cluster: 1/2 inch or 13mmMaximum length of CP indications in any continuous 12" length of weweld: 1/2" 13 mmMaximum length of an individual pore within a cluster: 1/16 inch or 2mmHollow Bead Porosity (HB)Maximum length of an individual indication of HB: 1/2 inch or 13mmMaximum length of HB indications in any continuous 12" length of weld: 2" 50 mmMaximum length of HB in 8% of weld: 28.7579 mmNOTE: The weld is unacceptable if individual indications of HB, each greater than 1/4 inch or 6mm in length, are seperated by less than 2 inches or 50 mm.

CRACKSNote: Any crack which is not a shallow crater crack or star crack is unacceptable.Maximum length of shallow crater cracks or star cracks: 5/32 inch or 4mm

UNDERCUTTINGUndercutting adjacent to the cover pass (EU) and Undercutting adjacent to the root pass (IU)Maximum length of EU and IU indications (in any combination) in a 12 inch length of weld: 2" 50 mmMaximum length of EU and IU indications: 2.35875" 59.9123 mm (This value is 1/6 th of the total weld length)

ACCUMULATION OF IMPERFECTIONSMaximum length of AI indications in any continuous 12 inch or 300 mm length of weld: 2" 50 mmMaximum length of AI indications of 8% of weld: 28.7579 mm

RADIOGRAPHIC INFOPipe O.D. in inches: 4.5"Amount of Penetrameters required for each shot: 1 penny in the center of the weldTotal weld length: 14.1525" 359.4735 mmCassette size to complete weld in most efficient way: 3.5 x 10" 4.5 x 10"Amount of shots to complete weld with 1" on each side of readable film: 58% of weld: 1.1322" 28.7579 mmHole penetrameters are adjacent to the weld and Wire penetrameters are parallel to the weld.

Page 2 of 2

Page 32: NDT Code Book Made Easy

PENETRAMETER SELECTIONNote: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Wire: 0.016 Esn. Wire: B4 S/S Hole: 20

F/S Wire: 0.013 Esn. Wire: B5 F/S Hole: 17Welds with reinforcement: S/S Wire: 0.020 Esn. Wire: B3 S/S Hole: 25

F/S Wire: 0.016 Esn. Wire: B4 F/S Hole: 20Maximum allowable reinforcement: 0.0625"/per sideMaximum reinforcement with DWE/SWV: 0.125" Total of walls + reinforcement: 1.473" 37.4142 mmMaximum reinforcement with DWE/DWV: 0.125" Total of walls + reinforcement: 1.473" 37.4142 mmMaximum reinforcement with SWE/SWV: 0.0625" Total of wall + reinforcement: 0.737" 18.7198 mm

INADEQUATE PENETRATION WITHOUT HIGH LOWMaximum length of individual indication of IP : 1 inch or 25mmMaximum length of IP in 8% of weld: N/A since total weld exceeds 12 inchesMaximum length of indications in any continuous 12" length of weld: 1" 25 mm

INADEQUATE PENETRATION DUE TO HIGH LOWMaximum length of individual indication of IPD: 2 inches or 50mmMaximum length of indications of IPD in any continuous 12" length of weld: 3" 75 mm

INADEQUATE CROSS PENETRATIONMaximum length of an individual indication of ICP: 2 inches or 50mmMaximum length of indications of ICP in any continuous 12" length of weld: 2" 50 mm

INCOMPLETE FUSIONMaximum length of an individual indication of IF: 1 inch or 25mmMaximum length of IF in 8% of weld: N/A since total weld exceeds 12 inchesMaximum length of indications of IF in any continuous 12" length of weld: 1" 25 mm

INCOMPLETE FUSION DUE TO COLD LAPMaximum length of individual indications of IFD: 2 inches or 50mmMaximum length of IFD in 8% of weld: 28.7579 mmMaximum length of indications of IFD in any continuous 12" length of weld: 2" 25 mm

INTERNAL CONCAVITY Any length of IC is acceptable, provided the density of the radiographic image of the internal concavity does not exceed that of the thinnest adjacent parent material. For areas that exceed the density of thethinnest adjacent parent material, the criteria for burn through are applicable.

BURN - THROUGHMaximum dimension of BT's image : unacceptable if it exceeds that of the thinnest adjacent parent metal.Maximum dimension of BT: 1/4" or 6mmMaximum dimension is unacceptable if: it exceeds the thinner of the nonnal wall thickness joined, and the density

of the BT's image exceeds that of the thinnest adjacent parent material.The sum of the max dimensions of separate BBT's whose image density exceeds that of the thinnest adjacent parentmaterial exceeds 1/2 inch or 13mm in any continuous 12" length of weld or the total weld length(whichever is less).

API - 11044" XX Strong - 0.674" Wall

Page 1 of 2

Page 33: NDT Code Book Made Easy

API - 11044" XX Strong - 0.674" Wall

SLAG INCLUSIONSElongated slag inclusions (ESI)Maximum length of an ESI: 2 inches or 50mmParallel ESI indications (Wagon Tracks) shall be considered a single indication unless the width of either of them exceed1/32" or 0.8mm. In that event they shall be considered separate indications.Maximum length of ESI indications in any continuous 12" length of weld: 2" 50 mmMaximum width of an individual ESI indication: 1/16" or 1.6mmIsolated slag inclusions (ISI)Maximum length of ISI indications in any continuous 12" length of weld: 1/2" 13 mmMaximum width of an ISI indication: 1/8" or 3mmMaximum length of ESI and ISI in 8% of weld: 28.7579 mm

POROSITY Individual or Scattered Porosity.Maximum size of an individual pore: 1/8" or 3mmThe size of an individual pore exceeds 25% of the thinner of the nonimal wall thickness joined.The distribution of scattered porosity exceeds the concentration permitted in Figures 19 or 20.Cluster Porosity (CP)Maximum diameter of the cluster: 1/2 inch or 13mmMaximum length of CP indications in any continuous 12" length of weweld: 1/2" 13 mmMaximum length of an individual pore within a cluster: 1/16 inch or 2mmHollow Bead Porosity (HB)Maximum length of an individual indication of HB: 1/2 inch or 13mmMaximum length of HB indications in any continuous 12" length of weld: 2" 50 mmMaximum length of HB in 8% of weld: 28.7579 mmNOTE: The weld is unacceptable if individual indications of HB, each greater than 1/4 inch or 6mm in length, are seperated by less than 2 inches or 50 mm.

CRACKSNote: Any crack which is not a shallow crater crack or star crack is unacceptable.Maximum length of shallow crater cracks or star cracks: 5/32 inch or 4mm

UNDERCUTTINGUndercutting adjacent to the cover pass (EU) and Undercutting adjacent to the root pass (IU)Maximum length of EU and IU indications (in any combination) in a 12 inch length of weld: 2" 50 mmMaximum length of EU and IU indications: 2.35875" 59.9123 mm (This value is 1/6 th of the total weld length)

ACCUMULATION OF IMPERFECTIONSMaximum length of AI indications in any continuous 12 inch or 300 mm length of weld: 2" 50 mmMaximum length of AI indications of 8% of weld: 28.7579 mm

RADIOGRAPHIC INFOPipe O.D. in inches: 4.5"Amount of Penetrameters required for each shot: 1 penny in the center of the weldTotal weld length: 14.1525" 359.4735 mmCassette size to complete weld in most efficient way: 3.5 x 10" 4.5 x 10"Amount of shots to complete weld with 1" on each side of readable film: 58% of weld: 1.1322" 28.7579 mmHole penetrameters are adjacent to the weld and Wire penetrameters are parallel to the weld.

Page 2 of 2

Page 34: NDT Code Book Made Easy

PENETRAMETER SELECTIONNote: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Wire: 0.008 Esn. Wire: A2 S/S Hole: 12

F/S Wire: 0.006 Esn. Wire: A3 F/S Hole: 10Welds with reinforcement: S/S Wire: 0.008 Esn. Wire: A2 S/S Hole: 12

F/S Wire: 0.006 Esn. Wire: A3 F/S Hole: 10Maximum allowable reinforcement: 0.0625"/per sideMaximum reinforcement with DWE/SWV: 0.125" Total of walls + reinforcement: 0.393" 9.9822 mmMaximum reinforcement with DWE/DWV: 0.125" Total of walls + reinforcement: 0.393" 9.9822 mmMaximum reinforcement with SWE/SWV: 0.0625" Total of wall + reinforcement: 0.197" 5.0038 mm

INADEQUATE PENETRATION WITHOUT HIGH LOWMaximum length of individual indication of IP : 1 inch or 25mmMaximum length of IP in 8% of weld: N/A since total weld exceeds 12 inchesMaximum length of indications in any continuous 12" length of weld: 1" 25 mm

INADEQUATE PENETRATION DUE TO HIGH LOWMaximum length of individual indication of IPD: 2 inches or 50mmMaximum length of indications of IPD in any continuous 12" length of weld: 3" 75 mm

INADEQUATE CROSS PENETRATIONMaximum length of an individual indication of ICP: 2 inches or 50mmMaximum length of indications of ICP in any continuous 12" length of weld: 2" 50 mm

INCOMPLETE FUSIONMaximum length of an individual indication of IF: 1 inch or 25mmMaximum length of IF in 8% of weld: N/A since total weld exceeds 12 inchesMaximum length of indications of IF in any continuous 12" length of weld: 1" 25 mm

INCOMPLETE FUSION DUE TO COLD LAPMaximum length of individual indications of IFD: 2 inches or 50mmMaximum length of IFD in 8% of weld: 42.3380 mmMaximum length of indications of IFD in any continuous 12" length of weld: 2" 25 mm

INTERNAL CONCAVITY Any length of IC is acceptable, provided the density of the radiographic image of the internal concavity does not exceed that of the thinnest adjacent parent material. For areas that exceed the density of thethinnest adjacent parent material, the criteria for burn through are applicable.

BURN - THROUGHMaximum dimension of BT's image : unacceptable if it exceeds that of the thinnest adjacent parent metal.Maximum dimension of BT: 1/4" or 6mmMaximum dimension is unacceptable if: it exceeds the thinner of the nonnal wall thickness joined, and the density

of the BT's image exceeds that of the thinnest adjacent parent material.The sum of the max dimensions of separate BBT's whose image density exceeds that of the thinnest adjacent parentmaterial exceeds 1/2 inch or 13mm in any continuous 12" length of weld or the total weld length(whichever is less).

API - 11046" s/10 - 0.134" Wall

Page 1 of 2

Page 35: NDT Code Book Made Easy

API - 11046" s/10 - 0.134" Wall

SLAG INCLUSIONSElongated slag inclusions (ESI)Maximum length of an ESI: 2 inches or 50mmParallel ESI indications (Wagon Tracks) shall be considered a single indication unless the width of either of them exceed1/32" or 0.8mm. In that event they shall be considered separate indications.Maximum length of ESI indications in any continuous 12" length of weld: 2" 50 mmMaximum width of an individual ESI indication: 1/16" or 1.6mmIsolated slag inclusions (ISI)Maximum length of ISI indications in any continuous 12" length of weld: 1/2" 13 mmMaximum width of an ISI indication: 1/8" or 3mmMaximum length of ESI and ISI in 8% of weld: 42.3380 mm

POROSITY Individual or Scattered Porosity.Maximum size of an individual pore: 1/8" or 3mmThe size of an individual pore exceeds 25% of the thinner of the nonimal wall thickness joined.The distribution of scattered porosity exceeds the concentration permitted in Figures 19 or 20.Cluster Porosity (CP)Maximum diameter of the cluster: 1/2 inch or 13mmMaximum length of CP indications in any continuous 12" length of weweld: 1/2" 13 mmMaximum length of an individual pore within a cluster: 1/16 inch or 2mmHollow Bead Porosity (HB)Maximum length of an individual indication of HB: 1/2 inch or 13mmMaximum length of HB indications in any continuous 12" length of weld: 2" 50 mmMaximum length of HB in 8% of weld: 42.3380 mmNOTE: The weld is unacceptable if individual indications of HB, each greater than 1/4 inch or 6mm in length, are seperated by less than 2 inches or 50 mm.

CRACKSNote: Any crack which is not a shallow crater crack or star crack is unacceptable.Maximum length of shallow crater cracks or star cracks: 5/32 inch or 4mm

UNDERCUTTINGUndercutting adjacent to the cover pass (EU) and Undercutting adjacent to the root pass (IU)Maximum length of EU and IU indications (in any combination) in a 12 inch length of weld: 2" 50 mmMaximum length of EU and IU indications: 3.473" 88.2142 mm (This value is 1/6 th of the total weld length)

ACCUMULATION OF IMPERFECTIONSMaximum length of AI indications in any continuous 12 inch or 300 mm length of weld: 2" 50 mmMaximum length of AI indications of 8% of weld: 42.3380 mm

RADIOGRAPHIC INFOPipe O.D. in inches: 6.625"Amount of Penetrameters required for each shot: 1 penetrameter 1" from the end of film and 1 penny in the center.Total weld length: 20.836" 529.2344 mmCassette size to complete weld in most efficient way: 3.5 x 10" 4.5 x 10"Amount of shots to complete weld with 1" on each side of readable film: 38% of weld: 1.66685" 42.3380 mmHole penetrameters are adjacent to the weld and Wire penetrameters are parallel to the weld.

Page 2 of 2

Page 36: NDT Code Book Made Easy

PENETRAMETER SELECTIONNote: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Wire: 0.010 Esn. Wire: A1 or B6 S/S Hole: 15

F/S Wire: 0.008 Esn. Wire: A2 F/S Hole: 12Welds with reinforcement: S/S Wire: 0.013 Esn. Wire: B5 S/S Hole: 17

F/S Wire: 0.010 Esn. Wire: A1 or B6 F/S Hole: 15Maximum allowable reinforcement: 0.0625"/per sideMaximum reinforcement with DWE/SWV: 0.125" Total of walls + reinforcement: 0.685" 17.3990 mmMaximum reinforcement with DWE/DWV: 0.125" Total of walls + reinforcement: 0.685" 17.3990 mmMaximum reinforcement with SWE/SWV: 0.0625" Total of wall + reinforcement: 0.343" 8.7122 mm

INADEQUATE PENETRATION WITHOUT HIGH LOWMaximum length of individual indication of IP : 1 inch or 25mmMaximum length of IP in 8% of weld: N/A since total weld exceeds 12 inchesMaximum length of indications in any continuous 12" length of weld: 1" 25 mm

INADEQUATE PENETRATION DUE TO HIGH LOWMaximum length of individual indication of IPD: 2 inches or 50mmMaximum length of indications of IPD in any continuous 12" length of weld: 3" 75 mm

INADEQUATE CROSS PENETRATIONMaximum length of an individual indication of ICP: 2 inches or 50mmMaximum length of indications of ICP in any continuous 12" length of weld: 2" 50 mm

INCOMPLETE FUSIONMaximum length of an individual indication of IF: 1 inch or 25mmMaximum length of IF in 8% of weld: N/A since total weld exceeds 12 inchesMaximum length of indications of IF in any continuous 12" length of weld: 1" 25 mm

INCOMPLETE FUSION DUE TO COLD LAPMaximum length of individual indications of IFD: 2 inches or 50mmMaximum length of IFD in 8% of weld: 42.3380 mmMaximum length of indications of IFD in any continuous 12" length of weld: 2" 25 mm

INTERNAL CONCAVITY Any length of IC is acceptable, provided the density of the radiographic image of the internal concavity does not exceed that of the thinnest adjacent parent material. For areas that exceed the density of thethinnest adjacent parent material, the criteria for burn through are applicable.

BURN - THROUGHMaximum dimension of BT's image : unacceptable if it exceeds that of the thinnest adjacent parent metal.Maximum dimension of BT: 1/4" or 6mmMaximum dimension is unacceptable if: it exceeds the thinner of the nonnal wall thickness joined, and the density

of the BT's image exceeds that of the thinnest adjacent parent material.The sum of the max dimensions of separate BBT's whose image density exceeds that of the thinnest adjacent parentmaterial exceeds 1/2 inch or 13mm in any continuous 12" length of weld or the total weld length(whichever is less).

API - 11046" s/40 & Std. - 0.280" Wall

Page 1 of 2

Page 37: NDT Code Book Made Easy

API - 11046" s/40 & Std. - 0.280" Wall

SLAG INCLUSIONSElongated slag inclusions (ESI)Maximum length of an ESI: 2 inches or 50mmParallel ESI indications (Wagon Tracks) shall be considered a single indication unless the width of either of them exceed1/32" or 0.8mm. In that event they shall be considered separate indications.Maximum length of ESI indications in any continuous 12" length of weld: 2" 50 mmMaximum width of an individual ESI indication: 1/16" or 1.6mmIsolated slag inclusions (ISI)Maximum length of ISI indications in any continuous 12" length of weld: 1/2" 13 mmMaximum width of an ISI indication: 1/8" or 3mmMaximum length of ESI and ISI in 8% of weld: 42.3380 mm

POROSITY Individual or Scattered Porosity.Maximum size of an individual pore: 1/8" or 3mmThe size of an individual pore exceeds 25% of the thinner of the nonimal wall thickness joined.The distribution of scattered porosity exceeds the concentration permitted in Figures 19 or 20.Cluster Porosity (CP)Maximum diameter of the cluster: 1/2 inch or 13mmMaximum length of CP indications in any continuous 12" length of weweld: 1/2" 13 mmMaximum length of an individual pore within a cluster: 1/16 inch or 2mmHollow Bead Porosity (HB)Maximum length of an individual indication of HB: 1/2 inch or 13mmMaximum length of HB indications in any continuous 12" length of weld: 2" 50 mmMaximum length of HB in 8% of weld: 42.3380 mmNOTE: The weld is unacceptable if individual indications of HB, each greater than 1/4 inch or 6mm in length, are seperated by less than 2 inches or 50 mm.

CRACKSNote: Any crack which is not a shallow crater crack or star crack is unacceptable.Maximum length of shallow crater cracks or star cracks: 5/32 inch or 4mm

UNDERCUTTINGUndercutting adjacent to the cover pass (EU) and Undercutting adjacent to the root pass (IU)Maximum length of EU and IU indications (in any combination) in a 12 inch length of weld: 2" 50 mmMaximum length of EU and IU indications: 3.473" 88.2142 mm (This value is 1/6 th of the total weld length)

ACCUMULATION OF IMPERFECTIONSMaximum length of AI indications in any continuous 12 inch or 300 mm length of weld: 2" 50 mmMaximum length of AI indications of 8% of weld: 42.3380 mm

RADIOGRAPHIC INFOPipe O.D. in inches: 6.625"Amount of Penetrameters required for each shot: 1 penetrameter 1" from the end of film and 1 penny in the center.Total weld length: 20.836" 529.2344 mmCassette size to complete weld in most efficient way: 3.5 x 10" 4.5 x 10"Amount of shots to complete weld with 1" on each side of readable film: 38% of weld: 1.66685" 42.3380 mmHole penetrameters are adjacent to the weld and Wire penetrameters are parallel to the weld.

Page 2 of 2

Page 38: NDT Code Book Made Easy

PENETRAMETER SELECTIONNote: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Wire: 0.013 Esn. Wire: B5 S/S Hole: 17

F/S Wire: 0.010 Esn. Wire: A1 or B6 F/S Hole: 15Welds with reinforcement: S/S Wire: 0.016 Esn. Wire: B4 S/S Hole: 20

F/S Wire: 0.013 Esn. Wire: B5 F/S Hole: 17Maximum allowable reinforcement: 0.0625"/per sideMaximum reinforcement with DWE/SWV: 0.125" Total of walls + reinforcement: 0.989" 25.1206 mmMaximum reinforcement with DWE/DWV: 0.125" Total of walls + reinforcement: 0.989" 25.1206 mmMaximum reinforcement with SWE/SWV: 0.0625" Total of wall + reinforcement: 0.495" 12.5730 mm

INADEQUATE PENETRATION WITHOUT HIGH LOWMaximum length of individual indication of IP : 1 inch or 25mmMaximum length of IP in 8% of weld: N/A since total weld exceeds 12 inchesMaximum length of indications in any continuous 12" length of weld: 1" 25 mm

INADEQUATE PENETRATION DUE TO HIGH LOWMaximum length of individual indication of IPD: 2 inches or 50mmMaximum length of indications of IPD in any continuous 12" length of weld: 3" 75 mm

INADEQUATE CROSS PENETRATIONMaximum length of an individual indication of ICP: 2 inches or 50mmMaximum length of indications of ICP in any continuous 12" length of weld: 2" 50 mm

INCOMPLETE FUSIONMaximum length of an individual indication of IF: 1 inch or 25mmMaximum length of IF in 8% of weld: N/A since total weld exceeds 12 inchesMaximum length of indications of IF in any continuous 12" length of weld: 1" 25 mm

INCOMPLETE FUSION DUE TO COLD LAPMaximum length of individual indications of IFD: 2 inches or 50mmMaximum length of IFD in 8% of weld: 42.3380 mmMaximum length of indications of IFD in any continuous 12" length of weld: 2" 25 mm

INTERNAL CONCAVITY Any length of IC is acceptable, provided the density of the radiographic image of the internal concavity does not exceed that of the thinnest adjacent parent material. For areas that exceed the density of thethinnest adjacent parent material, the criteria for burn through are applicable.

BURN - THROUGHMaximum dimension of BT's image : unacceptable if it exceeds that of the thinnest adjacent parent metal.Maximum dimension of BT: 1/4" or 6mmMaximum dimension is unacceptable if: it exceeds the thinner of the nonnal wall thickness joined, and the density

of the BT's image exceeds that of the thinnest adjacent parent material.The sum of the max dimensions of separate BBT's whose image density exceeds that of the thinnest adjacent parentmaterial exceeds 1/2 inch or 13mm in any continuous 12" length of weld or the total weld length(whichever is less).

API - 11046" s/80 & Extra Strong - 0.432" Wall

Page 1 of 2

Page 39: NDT Code Book Made Easy

API - 11046" s/80 & Extra Strong - 0.432" Wall

SLAG INCLUSIONSElongated slag inclusions (ESI)Maximum length of an ESI: 2 inches or 50mmParallel ESI indications (Wagon Tracks) shall be considered a single indication unless the width of either of them exceed1/32" or 0.8mm. In that event they shall be considered separate indications.Maximum length of ESI indications in any continuous 12" length of weld: 2" 50 mmMaximum width of an individual ESI indication: 1/16" or 1.6mmIsolated slag inclusions (ISI)Maximum length of ISI indications in any continuous 12" length of weld: 1/2" 13 mmMaximum width of an ISI indication: 1/8" or 3mmMaximum length of ESI and ISI in 8% of weld: 42.3380 mm

POROSITY Individual or Scattered Porosity.Maximum size of an individual pore: 1/8" or 3mmThe size of an individual pore exceeds 25% of the thinner of the nonimal wall thickness joined.The distribution of scattered porosity exceeds the concentration permitted in Figures 19 or 20.Cluster Porosity (CP)Maximum diameter of the cluster: 1/2 inch or 13mmMaximum length of CP indications in any continuous 12" length of weweld: 1/2" 13 mmMaximum length of an individual pore within a cluster: 1/16 inch or 2mmHollow Bead Porosity (HB)Maximum length of an individual indication of HB: 1/2 inch or 13mmMaximum length of HB indications in any continuous 12" length of weld: 2" 50 mmMaximum length of HB in 8% of weld: 42.3380 mmNOTE: The weld is unacceptable if individual indications of HB, each greater than 1/4 inch or 6mm in length, are seperated by less than 2 inches or 50 mm.

CRACKSNote: Any crack which is not a shallow crater crack or star crack is unacceptable.Maximum length of shallow crater cracks or star cracks: 5/32 inch or 4mm

UNDERCUTTINGUndercutting adjacent to the cover pass (EU) and Undercutting adjacent to the root pass (IU)Maximum length of EU and IU indications (in any combination) in a 12 inch length of weld: 2" 50 mmMaximum length of EU and IU indications: 3.473" 88.2142 mm (This value is 1/6 th of the total weld length)

ACCUMULATION OF IMPERFECTIONSMaximum length of AI indications in any continuous 12 inch or 300 mm length of weld: 2" 50 mmMaximum length of AI indications of 8% of weld: 42.3380 mm

RADIOGRAPHIC INFOPipe O.D. in inches: 6.625"Amount of Penetrameters required for each shot: 1 penetrameter 1" from the end of film and 1 penny in the center.Total weld length: 20.836" 529.2344 mmCassette size to complete weld in most efficient way: 3.5 x 10" 4.5 x 10"Amount of shots to complete weld with 1" on each side of readable film: 38% of weld: 1.66685" 42.3380 mmHole penetrameters are adjacent to the weld and Wire penetrameters are parallel to the weld.

Page 2 of 2

Page 40: NDT Code Book Made Easy

PENETRAMETER SELECTIONNote: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Wire: 0.016 Esn. Wire: B4 S/S Hole: 20

F/S Wire: 0.013 Esn. Wire: B5 F/S Hole: 17Welds with reinforcement: S/S Wire: 0.016 Esn. Wire: B4 S/S Hole: 20

F/S Wire: 0.013 Esn. Wire: B5 F/S Hole: 17Maximum allowable reinforcement: 0.0625"/per sideMaximum reinforcement with DWE/SWV: 0.125" Total of walls + reinforcement: 1.249" 31.7246 mmMaximum reinforcement with DWE/DWV: 0.125" Total of walls + reinforcement: 1.249" 31.7246 mmMaximum reinforcement with SWE/SWV: 0.0625" Total of wall + reinforcement: 0.625" 15.8750 mm

INADEQUATE PENETRATION WITHOUT HIGH LOWMaximum length of individual indication of IP : 1 inch or 25mmMaximum length of IP in 8% of weld: N/A since total weld exceeds 12 inchesMaximum length of indications in any continuous 12" length of weld: 1" 25 mm

INADEQUATE PENETRATION DUE TO HIGH LOWMaximum length of individual indication of IPD: 2 inches or 50mmMaximum length of indications of IPD in any continuous 12" length of weld: 3" 75 mm

INADEQUATE CROSS PENETRATIONMaximum length of an individual indication of ICP: 2 inches or 50mmMaximum length of indications of ICP in any continuous 12" length of weld: 2" 50 mm

INCOMPLETE FUSIONMaximum length of an individual indication of IF: 1 inch or 25mmMaximum length of IF in 8% of weld: N/A since total weld exceeds 12 inchesMaximum length of indications of IF in any continuous 12" length of weld: 1" 25 mm

INCOMPLETE FUSION DUE TO COLD LAPMaximum length of individual indications of IFD: 2 inches or 50mmMaximum length of IFD in 8% of weld: 42.3380 mmMaximum length of indications of IFD in any continuous 12" length of weld: 2" 25 mm

INTERNAL CONCAVITY Any length of IC is acceptable, provided the density of the radiographic image of the internal concavity does not exceed that of the thinnest adjacent parent material. For areas that exceed the density of thethinnest adjacent parent material, the criteria for burn through are applicable.

BURN - THROUGHMaximum dimension of BT's image : unacceptable if it exceeds that of the thinnest adjacent parent metal.Maximum dimension of BT: 1/4" or 6mmMaximum dimension is unacceptable if: it exceeds the thinner of the nonnal wall thickness joined, and the density

of the BT's image exceeds that of the thinnest adjacent parent material.The sum of the max dimensions of separate BBT's whose image density exceeds that of the thinnest adjacent parentmaterial exceeds 1/2 inch or 13mm in any continuous 12" length of weld or the total weld length(whichever is less).

API - 11046" s/120 - 0.562" Wall

Page 1 of 2

Page 41: NDT Code Book Made Easy

API - 11046" s/120 - 0.562" Wall

SLAG INCLUSIONSElongated slag inclusions (ESI)Maximum length of an ESI: 2 inches or 50mmParallel ESI indications (Wagon Tracks) shall be considered a single indication unless the width of either of them exceed1/32" or 0.8mm. In that event they shall be considered separate indications.Maximum length of ESI indications in any continuous 12" length of weld: 2" 50 mmMaximum width of an individual ESI indication: 1/16" or 1.6mmIsolated slag inclusions (ISI)Maximum length of ISI indications in any continuous 12" length of weld: 1/2" 13 mmMaximum width of an ISI indication: 1/8" or 3mmMaximum length of ESI and ISI in 8% of weld: 42.3380 mm

POROSITY Individual or Scattered Porosity.Maximum size of an individual pore: 1/8" or 3mmThe size of an individual pore exceeds 25% of the thinner of the nonimal wall thickness joined.The distribution of scattered porosity exceeds the concentration permitted in Figures 19 or 20.Cluster Porosity (CP)Maximum diameter of the cluster: 1/2 inch or 13mmMaximum length of CP indications in any continuous 12" length of weweld: 1/2" 13 mmMaximum length of an individual pore within a cluster: 1/16 inch or 2mmHollow Bead Porosity (HB)Maximum length of an individual indication of HB: 1/2 inch or 13mmMaximum length of HB indications in any continuous 12" length of weld: 2" 50 mmMaximum length of HB in 8% of weld: 42.3380 mmNOTE: The weld is unacceptable if individual indications of HB, each greater than 1/4 inch or 6mm in length, are seperated by less than 2 inches or 50 mm.

CRACKSNote: Any crack which is not a shallow crater crack or star crack is unacceptable.Maximum length of shallow crater cracks or star cracks: 5/32 inch or 4mm

UNDERCUTTINGUndercutting adjacent to the cover pass (EU) and Undercutting adjacent to the root pass (IU)Maximum length of EU and IU indications (in any combination) in a 12 inch length of weld: 2" 50 mmMaximum length of EU and IU indications: 3.473" 88.2142 mm (This value is 1/6 th of the total weld length)

ACCUMULATION OF IMPERFECTIONSMaximum length of AI indications in any continuous 12 inch or 300 mm length of weld: 2" 50 mmMaximum length of AI indications of 8% of weld: 42.3380 mm

RADIOGRAPHIC INFOPipe O.D. in inches: 6.625"Amount of Penetrameters required for each shot: 1 penetrameter 1" from the end of film and 1 penny in the center.Total weld length: 20.836" 529.2344 mmCassette size to complete weld in most efficient way: 3.5 x 10" 4.5 x 10"Amount of shots to complete weld with 1" on each side of readable film: 48% of weld: 1.66685" 42.3380 mmHole penetrameters are adjacent to the weld and Wire penetrameters are parallel to the weld.

Page 2 of 2

Page 42: NDT Code Book Made Easy

PENETRAMETER SELECTIONNote: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Wire: 0.016 Esn. Wire: B4 S/S Hole: 20

F/S Wire: 0.013 Esn. Wire: B5 F/S Hole: 17Welds with reinforcement: S/S Wire: 0.020 Esn. Wire: B3 S/S Hole: 25

F/S Wire: 0.016 Esn. Wire: B4 F/S Hole: 20Maximum allowable reinforcement: 0.0625"/per sideMaximum reinforcement with DWE/SWV: 0.125" Total of walls + reinforcement: 1.563" 39.7002 mmMaximum reinforcement with DWE/DWV: 0.125" Total of walls + reinforcement: 1.563" 39.7002 mmMaximum reinforcement with SWE/SWV: 0.0625" Total of wall + reinforcement: 0.782" 19.8628 mm

INADEQUATE PENETRATION WITHOUT HIGH LOWMaximum length of individual indication of IP : 1 inch or 25mmMaximum length of IP in 8% of weld: N/A since total weld exceeds 12 inchesMaximum length of indications in any continuous 12" length of weld: 1" 25 mm

INADEQUATE PENETRATION DUE TO HIGH LOWMaximum length of individual indication of IPD: 2 inches or 50mmMaximum length of indications of IPD in any continuous 12" length of weld: 3" 75 mm

INADEQUATE CROSS PENETRATIONMaximum length of an individual indication of ICP: 2 inches or 50mmMaximum length of indications of ICP in any continuous 12" length of weld: 2" 50 mm

INCOMPLETE FUSIONMaximum length of an individual indication of IF: 1 inch or 25mmMaximum length of IF in 8% of weld: N/A since total weld exceeds 12 inchesMaximum length of indications of IF in any continuous 12" length of weld: 1" 25 mm

INCOMPLETE FUSION DUE TO COLD LAPMaximum length of individual indications of IFD: 2 inches or 50mmMaximum length of IFD in 8% of weld: 42.3380 mmMaximum length of indications of IFD in any continuous 12" length of weld: 2" 25 mm

INTERNAL CONCAVITY Any length of IC is acceptable, provided the density of the radiographic image of the internal concavity does not exceed that of the thinnest adjacent parent material. For areas that exceed the density of thethinnest adjacent parent material, the criteria for burn through are applicable.

BURN - THROUGHMaximum dimension of BT's image : unacceptable if it exceeds that of the thinnest adjacent parent metal.Maximum dimension of BT: 1/4" or 6mmMaximum dimension is unacceptable if: it exceeds the thinner of the nonnal wall thickness joined, and the density

of the BT's image exceeds that of the thinnest adjacent parent material.The sum of the max dimensions of separate BBT's whose image density exceeds that of the thinnest adjacent parentmaterial exceeds 1/2 inch or 13mm in any continuous 12" length of weld or the total weld length(whichever is less).

API - 11046" s/160 - 0.719" Wall

Page 1 of 2

Page 43: NDT Code Book Made Easy

API - 11046" s/160 - 0.719" Wall

SLAG INCLUSIONSElongated slag inclusions (ESI)Maximum length of an ESI: 2 inches or 50mmParallel ESI indications (Wagon Tracks) shall be considered a single indication unless the width of either of them exceed1/32" or 0.8mm. In that event they shall be considered separate indications.Maximum length of ESI indications in any continuous 12" length of weld: 2" 50 mmMaximum width of an individual ESI indication: 1/16" or 1.6mmIsolated slag inclusions (ISI)Maximum length of ISI indications in any continuous 12" length of weld: 1/2" 13 mmMaximum width of an ISI indication: 1/8" or 3mmMaximum length of ESI and ISI in 8% of weld: 42.3380 mm

POROSITY Individual or Scattered Porosity.Maximum size of an individual pore: 1/8" or 3mmThe size of an individual pore exceeds 25% of the thinner of the nonimal wall thickness joined.The distribution of scattered porosity exceeds the concentration permitted in Figures 19 or 20.Cluster Porosity (CP)Maximum diameter of the cluster: 1/2 inch or 13mmMaximum length of CP indications in any continuous 12" length of weweld: 1/2" 13 mmMaximum length of an individual pore within a cluster: 1/16 inch or 2mmHollow Bead Porosity (HB)Maximum length of an individual indication of HB: 1/2 inch or 13mmMaximum length of HB indications in any continuous 12" length of weld: 2" 50 mmMaximum length of HB in 8% of weld: 42.3380 mmNOTE: The weld is unacceptable if individual indications of HB, each greater than 1/4 inch or 6mm in length, are seperated by less than 2 inches or 50 mm.

CRACKSNote: Any crack which is not a shallow crater crack or star crack is unacceptable.Maximum length of shallow crater cracks or star cracks: 5/32 inch or 4mm

UNDERCUTTINGUndercutting adjacent to the cover pass (EU) and Undercutting adjacent to the root pass (IU)Maximum length of EU and IU indications (in any combination) in a 12 inch length of weld: 2" 50 mmMaximum length of EU and IU indications: 3.473" 88.2142 mm (This value is 1/6 th of the total weld length)

ACCUMULATION OF IMPERFECTIONSMaximum length of AI indications in any continuous 12 inch or 300 mm length of weld: 2" 50 mmMaximum length of AI indications of 8% of weld: 42.3380 mm

RADIOGRAPHIC INFOPipe O.D. in inches: 6.625"Amount of Penetrameters required for each shot: 1 penetrameter 1" from the end of film and 1 penny in the center.Total weld length: 20.836" 529.2344 mmCassette size to complete weld in most efficient way: 3.5 x 10" 4.5 x 10"Amount of shots to complete weld with 1" on each side of readable film: 58% of weld: 1.66685" 42.3380 mmHole penetrameters are adjacent to the weld and Wire penetrameters are parallel to the weld.

Page 2 of 2

Page 44: NDT Code Book Made Easy

PENETRAMETER SELECTIONNote: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Wire: 0.020 Esn. Wire: B3 S/S Hole: 25

F/S Wire: 0.016 Esn. Wire: B4 F/S Hole: 20Welds with reinforcement: S/S Wire: 0.025 Esn. Wire: B2 S/S Hole: 30

F/S Wire: 0.020 Esn. Wire: B3 F/S Hole: 25Maximum allowable reinforcement: 0.0625"/per sideMaximum reinforcement with DWE/SWV: 0.125" Total of walls + reinforcement: 1.853" 47.0662 mmMaximum reinforcement with DWE/DWV: 0.125" Total of walls + reinforcement: 1.853" 47.0662 mmMaximum reinforcement with SWE/SWV: 0.0625" Total of wall + reinforcement: 0.927" 23.5458 mm

INADEQUATE PENETRATION WITHOUT HIGH LOWMaximum length of individual indication of IP : 1 inch or 25mmMaximum length of IP in 8% of weld: N/A since total weld exceeds 12 inchesMaximum length of indications in any continuous 12" length of weld: 1" 25 mm

INADEQUATE PENETRATION DUE TO HIGH LOWMaximum length of individual indication of IPD: 2 inches or 50mmMaximum length of indications of IPD in any continuous 12" length of weld: 3" 75 mm

INADEQUATE CROSS PENETRATIONMaximum length of an individual indication of ICP: 2 inches or 50mmMaximum length of indications of ICP in any continuous 12" length of weld: 2" 50 mm

INCOMPLETE FUSIONMaximum length of an individual indication of IF: 1 inch or 25mmMaximum length of IF in 8% of weld: N/A since total weld exceeds 12 inchesMaximum length of indications of IF in any continuous 12" length of weld: 1" 25 mm

INCOMPLETE FUSION DUE TO COLD LAPMaximum length of individual indications of IFD: 2 inches or 50mmMaximum length of IFD in 8% of weld: 42.3380 mmMaximum length of indications of IFD in any continuous 12" length of weld: 2" 25 mm

INTERNAL CONCAVITY Any length of IC is acceptable, provided the density of the radiographic image of the internal concavity does not exceed that of the thinnest adjacent parent material. For areas that exceed the density of thethinnest adjacent parent material, the criteria for burn through are applicable.

BURN - THROUGHMaximum dimension of BT's image : unacceptable if it exceeds that of the thinnest adjacent parent metal.Maximum dimension of BT: 1/4" or 6mmMaximum dimension is unacceptable if: it exceeds the thinner of the nonnal wall thickness joined, and the density

of the BT's image exceeds that of the thinnest adjacent parent material.The sum of the max dimensions of separate BBT's whose image density exceeds that of the thinnest adjacent parentmaterial exceeds 1/2 inch or 13mm in any continuous 12" length of weld or the total weld length(whichever is less).

API - 11046" XX Strong - 0.864" Wall

Page 1 of 2

Page 45: NDT Code Book Made Easy

API - 11046" XX Strong - 0.864" Wall

SLAG INCLUSIONSElongated slag inclusions (ESI)Maximum length of an ESI: 2 inches or 50mmParallel ESI indications (Wagon Tracks) shall be considered a single indication unless the width of either of them exceed1/32" or 0.8mm. In that event they shall be considered separate indications.Maximum length of ESI indications in any continuous 12" length of weld: 2" 50 mmMaximum width of an individual ESI indication: 1/16" or 1.6mmIsolated slag inclusions (ISI)Maximum length of ISI indications in any continuous 12" length of weld: 1/2" 13 mmMaximum width of an ISI indication: 1/8" or 3mmMaximum length of ESI and ISI in 8% of weld: 42.3380 mm

POROSITY Individual or Scattered Porosity.Maximum size of an individual pore: 1/8" or 3mmThe size of an individual pore exceeds 25% of the thinner of the nonimal wall thickness joined.The distribution of scattered porosity exceeds the concentration permitted in Figures 19 or 20.Cluster Porosity (CP)Maximum diameter of the cluster: 1/2 inch or 13mmMaximum length of CP indications in any continuous 12" length of weweld: 1/2" 13 mmMaximum length of an individual pore within a cluster: 1/16 inch or 2mmHollow Bead Porosity (HB)Maximum length of an individual indication of HB: 1/2 inch or 13mmMaximum length of HB indications in any continuous 12" length of weld: 2" 50 mmMaximum length of HB in 8% of weld: 42.3380 mmNOTE: The weld is unacceptable if individual indications of HB, each greater than 1/4 inch or 6mm in length, are seperated by less than 2 inches or 50 mm.

CRACKSNote: Any crack which is not a shallow crater crack or star crack is unacceptable.Maximum length of shallow crater cracks or star cracks: 5/32 inch or 4mm

UNDERCUTTINGUndercutting adjacent to the cover pass (EU) and Undercutting adjacent to the root pass (IU)Maximum length of EU and IU indications (in any combination) in a 12 inch length of weld: 2" 50 mmMaximum length of EU and IU indications: 3.473" 88.2142 mm (This value is 1/6 th of the total weld length)

ACCUMULATION OF IMPERFECTIONSMaximum length of AI indications in any continuous 12 inch or 300 mm length of weld: 2" 50 mmMaximum length of AI indications of 8% of weld: 42.3380 mm

RADIOGRAPHIC INFOPipe O.D. in inches: 6.625"Amount of Penetrameters required for each shot: 1 penetrameter 1" from the end of film and 1 penny in the center.Total weld length: 20.836" 529.2344 mmCassette size to complete weld in most efficient way: 3.5 x 10" 4.5 x 10"Amount of shots to complete weld with 1" on each side of readable film: 58% of weld: 1.66685" 42.3380 mmHole penetrameters are adjacent to the weld and Wire penetrameters are parallel to the weld.

Page 2 of 2

Page 46: NDT Code Book Made Easy

PENETRAMETER SELECTIONNote: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Wire: 0.008 Esn. Wire: A2 S/S Hole: 12

F/S Wire: 0.006 Esn. Wire: A3 F/S Hole: 10Welds with reinforcement: S/S Wire: 0.008 Esn. Wire: A2 S/S Hole: 12

F/S Wire: 0.006 Esn. Wire: A3 F/S Hole: 10Maximum allowable reinforcement: 0.0625"/per sideMaximum reinforcement with DWE/SWV: 0.125" Total of walls + reinforcement: 0.296" 7.5184 mmMaximum reinforcement with DWE/DWV: 0.125" Total of walls + reinforcement: 0.296" 7.5184 mmMaximum reinforcement with SWE/SWV: 0.0625" Total of wall + reinforcement: 0.211" 5.3594 mm

INADEQUATE PENETRATION WITHOUT HIGH LOWMaximum length of individual indication of IP : 1 inch or 25mmMaximum length of IP in 8% of weld: N/A since total weld exceeds 12 inchesMaximum length of indications in any continuous 12" length of weld: 1" 25 mm

INADEQUATE PENETRATION DUE TO HIGH LOWMaximum length of individual indication of IPD: 2 inches or 50mmMaximum length of indications of IPD in any continuous 12" length of weld: 3" 75 mm

INADEQUATE CROSS PENETRATIONMaximum length of an individual indication of ICP: 2 inches or 50mmMaximum length of indications of ICP in any continuous 12" length of weld: 2" 50 mm

INCOMPLETE FUSIONMaximum length of an individual indication of IF: 1 inch or 25mmMaximum length of IF in 8% of weld: N/A since total weld exceeds 12 inchesMaximum length of indications of IF in any continuous 12" length of weld: 1" 25 mm

INCOMPLETE FUSION DUE TO COLD LAPMaximum length of individual indications of IFD: 2 inches or 50mmMaximum length of IFD in 8% of weld: 55.1193 mmMaximum length of indications of IFD in any continuous 12" length of weld: 2" 25 mm

INTERNAL CONCAVITY Any length of IC is acceptable, provided the density of the radiographic image of the internal concavity does not exceed that of the thinnest adjacent parent material. For areas that exceed the density of thethinnest adjacent parent material, the criteria for burn through are applicable.

BURN - THROUGHMaximum dimension of BT's image : unacceptable if it exceeds that of the thinnest adjacent parent metal.Maximum dimension of BT: 1/4" or 6mmMaximum dimension is unacceptable if: it exceeds the thinner of the nonnal wall thickness joined, and the density

of the BT's image exceeds that of the thinnest adjacent parent material.The sum of the max dimensions of separate BBT's whose image density exceeds that of the thinnest adjacent parentmaterial exceeds 1/2 inch or 13mm in any continuous 12" length of weld or the total weld length(whichever is less).

API - 11048" s/10 - 0.148" Wall

Page 1 of 2

Page 47: NDT Code Book Made Easy

API - 11048" s/10 - 0.148" Wall

SLAG INCLUSIONSElongated slag inclusions (ESI)Maximum length of an ESI: 2 inches or 50mmParallel ESI indications (Wagon Tracks) shall be considered a single indication unless the width of either of them exceed1/32" or 0.8mm. In that event they shall be considered separate indications.Maximum length of ESI indications in any continuous 12" length of weld: 2" 50 mmMaximum width of an individual ESI indication: 1/16" or 1.6mmIsolated slag inclusions (ISI)Maximum length of ISI indications in any continuous 12" length of weld: 1/2" 13 mmMaximum width of an ISI indication: 1/8" or 3mmMaximum length of ESI and ISI in 8% of weld: 55.1193 mm

POROSITY Individual or Scattered Porosity.Maximum size of an individual pore: 1/8" or 3mmThe size of an individual pore exceeds 25% of the thinner of the nonimal wall thickness joined.The distribution of scattered porosity exceeds the concentration permitted in Figures 19 or 20.Cluster Porosity (CP)Maximum diameter of the cluster: 1/2 inch or 13mmMaximum length of CP indications in any continuous 12" length of weweld: 1/2" 13 mmMaximum length of an individual pore within a cluster: 1/16 inch or 2mmHollow Bead Porosity (HB)Maximum length of an individual indication of HB: 1/2 inch or 13mmMaximum length of HB indications in any continuous 12" length of weld: 2" 50 mmMaximum length of HB in 8% of weld: 55.1193 mmNOTE: The weld is unacceptable if individual indications of HB, each greater than 1/4 inch or 6mm in length, are seperated by less than 2 inches or 50 mm.

CRACKSNote: Any crack which is not a shallow crater crack or star crack is unacceptable.Maximum length of shallow crater cracks or star cracks: 5/32 inch or 4mm

UNDERCUTTINGUndercutting adjacent to the cover pass (EU) and Undercutting adjacent to the root pass (IU)Maximum length of EU and IU indications (in any combination) in a 12 inch length of weld: 2" 50 mmMaximum length of EU and IU indications: 4.521 114.8334 mm (This value is 1/6 th of the total weld length)

ACCUMULATION OF IMPERFECTIONSMaximum length of AI indications in any continuous 12 inch or 300 mm length of weld: 2" 50 mmMaximum length of AI indications of 8% of weld: 55.1193 mm

RADIOGRAPHIC INFOPipe O.D. in inches: 8.625"Amount of Penetrameters required for each shot: 1 penetrameter 1" from the end of film and 1 penny in the center.Total weld length: 27.125625" 688.9909 mmCassette size to complete weld in most efficient way: 3.5 x 17" 4.5 x 17"Amount of shots to complete weld with 1" on each side of readable film: 38% of weld: 2.17005" 55.1193 mmHole penetrameters are adjacent to the weld and Wire penetrameters are parallel to the weld.

Page 2 of 2

Page 48: NDT Code Book Made Easy

PENETRAMETER SELECTIONNote: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Wire: 0.010 Esn. Wire: A1 or B6 S/S Hole: 15

F/S Wire: 0.008 Esn. Wire: A2 F/S Hole: 12Welds with reinforcement: S/S Wire: 0.013 Esn. Wire: B5 S/S Hole: 17

F/S Wire: 0.010 Esn. Wire: A1 or B6 F/S Hole: 15Maximum allowable reinforcement: 0.0625"/per sideMaximum reinforcement with DWE/SWV: 0.125" Total of walls + reinforcement: 0.769" 19.5326 mmMaximum reinforcement with DWE/DWV: 0.125" Total of walls + reinforcement: 0.769" 19.5326 mmMaximum reinforcement with SWE/SWV: 0.0625" Total of wall + reinforcement: 0.385" 9.7790 mm

INADEQUATE PENETRATION WITHOUT HIGH LOWMaximum length of individual indication of IP : 1 inch or 25mmMaximum length of IP in 8% of weld: N/A since total weld exceeds 12 inchesMaximum length of indications in any continuous 12" length of weld: 1" 25 mm

INADEQUATE PENETRATION DUE TO HIGH LOWMaximum length of individual indication of IPD: 2 inches or 50mmMaximum length of indications of IPD in any continuous 12" length of weld: 3" 75 mm

INADEQUATE CROSS PENETRATIONMaximum length of an individual indication of ICP: 2 inches or 50mmMaximum length of indications of ICP in any continuous 12" length of weld: 2" 50 mm

INCOMPLETE FUSIONMaximum length of an individual indication of IF: 1 inch or 25mmMaximum length of IF in 8% of weld: N/A since total weld exceeds 12 inchesMaximum length of indications of IF in any continuous 12" length of weld: 1" 25 mm

INCOMPLETE FUSION DUE TO COLD LAPMaximum length of individual indications of IFD: 2 inches or 50mmMaximum length of IFD in 8% of weld: 55.1193 mmMaximum length of indications of IFD in any continuous 12" length of weld: 2" 25 mm

INTERNAL CONCAVITY Any length of IC is acceptable, provided the density of the radiographic image of the internal concavity does not exceed that of the thinnest adjacent parent material. For areas that exceed the density of thethinnest adjacent parent material, the criteria for burn through are applicable.

BURN - THROUGHMaximum dimension of BT's image : unacceptable if it exceeds that of the thinnest adjacent parent metal.Maximum dimension of BT: 1/4" or 6mmMaximum dimension is unacceptable if: it exceeds the thinner of the nonnal wall thickness joined, and the density

of the BT's image exceeds that of the thinnest adjacent parent material.The sum of the max dimensions of separate BBT's whose image density exceeds that of the thinnest adjacent parentmaterial exceeds 1/2 inch or 13mm in any continuous 12" length of weld or the total weld length(whichever is less).

API - 11048" s/40 & Std. - 0.322" Wall

Page 1 of 2

Page 49: NDT Code Book Made Easy

API - 11048" s/40 & Std. - 0.322" Wall

SLAG INCLUSIONSElongated slag inclusions (ESI)Maximum length of an ESI: 2 inches or 50mmParallel ESI indications (Wagon Tracks) shall be considered a single indication unless the width of either of them exceed1/32" or 0.8mm. In that event they shall be considered separate indications.Maximum length of ESI indications in any continuous 12" length of weld: 2" 50 mmMaximum width of an individual ESI indication: 1/16" or 1.6mmIsolated slag inclusions (ISI)Maximum length of ISI indications in any continuous 12" length of weld: 1/2" 13 mmMaximum width of an ISI indication: 1/8" or 3mmMaximum length of ESI and ISI in 8% of weld: 55.1193 mm

POROSITY Individual or Scattered Porosity.Maximum size of an individual pore: 1/8" or 3mmThe size of an individual pore exceeds 25% of the thinner of the nonimal wall thickness joined.The distribution of scattered porosity exceeds the concentration permitted in Figures 19 or 20.Cluster Porosity (CP)Maximum diameter of the cluster: 1/2 inch or 13mmMaximum length of CP indications in any continuous 12" length of weweld: 1/2" 13 mmMaximum length of an individual pore within a cluster: 1/16 inch or 2mmHollow Bead Porosity (HB)Maximum length of an individual indication of HB: 1/2 inch or 13mmMaximum length of HB indications in any continuous 12" length of weld: 2" 50 mmMaximum length of HB in 8% of weld: 55.1193 mmNOTE: The weld is unacceptable if individual indications of HB, each greater than 1/4 inch or 6mm in length, are seperated by less than 2 inches or 50 mm.

CRACKSNote: Any crack which is not a shallow crater crack or star crack is unacceptable.Maximum length of shallow crater cracks or star cracks: 5/32 inch or 4mm

UNDERCUTTINGUndercutting adjacent to the cover pass (EU) and Undercutting adjacent to the root pass (IU)Maximum length of EU and IU indications (in any combination) in a 12 inch length of weld: 2" 50 mmMaximum length of EU and IU indications: 4.521 114.8334 mm (This value is 1/6 th of the total weld length)

ACCUMULATION OF IMPERFECTIONSMaximum length of AI indications in any continuous 12 inch or 300 mm length of weld: 2" 50 mmMaximum length of AI indications of 8% of weld: 55.1193 mm

RADIOGRAPHIC INFOPipe O.D. in inches: 8.625"Amount of Penetrameters required for each shot: 1 penetrameter 1" from the end of film and 1 penny in the center.Total weld length: 27.125625" 688.9909 mmCassette size to complete weld in most efficient way: 3.5 x 17" 4.5 x 17"Amount of shots to complete weld with 1" on each side of readable film: 38% of weld: 2.17005" 55.1193 mmHole penetrameters are adjacent to the weld and Wire penetrameters are parallel to the weld.

Page 2 of 2

Page 50: NDT Code Book Made Easy

PENETRAMETER SELECTIONNote: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Wire: 0.013 Esn. Wire: B5 S/S Hole: 17

F/S Wire: 0.010 Esn. Wire: A1 or B6 F/S Hole: 15Welds with reinforcement: S/S Wire: 0.016 Esn. Wire: B4 S/S Hole: 20

F/S Wire: 0.013 Esn. Wire: B5 F/S Hole: 17Maximum allowable reinforcement: 0.0625"/per sideMaximum reinforcement with DWE/SWV: 0.125" Total of walls + reinforcement: 1.125" 28.5750 mmMaximum reinforcement with DWE/DWV: 0.125" Total of walls + reinforcement: 1.125" 28.5750 mmMaximum reinforcement with SWE/SWV: 0.0625" Total of wall + reinforcement: 0.5625" 14.2875 mm

INADEQUATE PENETRATION WITHOUT HIGH LOWMaximum length of individual indication of IP : 1 inch or 25mmMaximum length of IP in 8% of weld: N/A since total weld exceeds 12 inchesMaximum length of indications in any continuous 12" length of weld: 1" 25 mm

INADEQUATE PENETRATION DUE TO HIGH LOWMaximum length of individual indication of IPD: 2 inches or 50mmMaximum length of indications of IPD in any continuous 12" length of weld: 3" 75 mm

INADEQUATE CROSS PENETRATIONMaximum length of an individual indication of ICP: 2 inches or 50mmMaximum length of indications of ICP in any continuous 12" length of weld: 2" 50 mm

INCOMPLETE FUSIONMaximum length of an individual indication of IF: 1 inch or 25mmMaximum length of IF in 8% of weld: N/A since total weld exceeds 12 inchesMaximum length of indications of IF in any continuous 12" length of weld: 1" 25 mm

INCOMPLETE FUSION DUE TO COLD LAPMaximum length of individual indications of IFD: 2 inches or 50mmMaximum length of IFD in 8% of weld: 55.1193 mmMaximum length of indications of IFD in any continuous 12" length of weld: 2" 25 mm

INTERNAL CONCAVITY Any length of IC is acceptable, provided the density of the radiographic image of the internal concavity does not exceed that of the thinnest adjacent parent material. For areas that exceed the density of thethinnest adjacent parent material, the criteria for burn through are applicable.

BURN - THROUGHMaximum dimension of BT's image : unacceptable if it exceeds that of the thinnest adjacent parent metal.Maximum dimension of BT: 1/4" or 6mmMaximum dimension is unacceptable if: it exceeds the thinner of the nonnal wall thickness joined, and the density

of the BT's image exceeds that of the thinnest adjacent parent material.The sum of the max dimensions of separate BBT's whose image density exceeds that of the thinnest adjacent parentmaterial exceeds 1/2 inch or 13mm in any continuous 12" length of weld or the total weld length(whichever is less).

API - 11048" s/80 & Extra Strong - 0.500" Wall

Page 1 of 2

Page 51: NDT Code Book Made Easy

API - 11048" s/80 & Extra Strong - 0.500" Wall

SLAG INCLUSIONSElongated slag inclusions (ESI)Maximum length of an ESI: 2 inches or 50mmParallel ESI indications (Wagon Tracks) shall be considered a single indication unless the width of either of them exceed1/32" or 0.8mm. In that event they shall be considered separate indications.Maximum length of ESI indications in any continuous 12" length of weld: 2" 50 mmMaximum width of an individual ESI indication: 1/16" or 1.6mmIsolated slag inclusions (ISI)Maximum length of ISI indications in any continuous 12" length of weld: 1/2" 13 mmMaximum width of an ISI indication: 1/8" or 3mmMaximum length of ESI and ISI in 8% of weld: 55.1193 mm

POROSITY Individual or Scattered Porosity.Maximum size of an individual pore: 1/8" or 3mmThe size of an individual pore exceeds 25% of the thinner of the nonimal wall thickness joined.The distribution of scattered porosity exceeds the concentration permitted in Figures 19 or 20.Cluster Porosity (CP)Maximum diameter of the cluster: 1/2 inch or 13mmMaximum length of CP indications in any continuous 12" length of weweld: 1/2" 13 mmMaximum length of an individual pore within a cluster: 1/16 inch or 2mmHollow Bead Porosity (HB)Maximum length of an individual indication of HB: 1/2 inch or 13mmMaximum length of HB indications in any continuous 12" length of weld: 2" 50 mmMaximum length of HB in 8% of weld: 55.1193 mmNOTE: The weld is unacceptable if individual indications of HB, each greater than 1/4 inch or 6mm in length, are seperated by less than 2 inches or 50 mm.

CRACKSNote: Any crack which is not a shallow crater crack or star crack is unacceptable.Maximum length of shallow crater cracks or star cracks: 5/32 inch or 4mm

UNDERCUTTINGUndercutting adjacent to the cover pass (EU) and Undercutting adjacent to the root pass (IU)Maximum length of EU and IU indications (in any combination) in a 12 inch length of weld: 2" 50 mmMaximum length of EU and IU indications: 4.521 114.8334 mm (This value is 1/6 th of the total weld length)

ACCUMULATION OF IMPERFECTIONSMaximum length of AI indications in any continuous 12 inch or 300 mm length of weld: 2" 50 mmMaximum length of AI indications of 8% of weld: 55.1193 mm

RADIOGRAPHIC INFOPipe O.D. in inches: 8.625"Amount of Penetrameters required for each shot: 1 penetrameter 1" from the end of film and 1 penny in the center.Total weld length: 27.125625" 688.9909 mmCassette size to complete weld in most efficient way: 3.5 x 17" 4.5 x 17"Amount of shots to complete weld with 1" on each side of readable film: 38% of weld: 2.17005" 55.1193 mmHole penetrameters are adjacent to the weld and Wire penetrameters are parallel to the weld.

Page 2 of 2

Page 52: NDT Code Book Made Easy

PENETRAMETER SELECTIONNote: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Wire: 0.020 Esn. Wire: B3 S/S Hole: 25

F/S Wire: 0.016 Esn. Wire: B4 F/S Hole: 20Welds with reinforcement: S/S Wire: 0.025 Esn. Wire: B2 S/S Hole: 30

F/S Wire: 0.020 Esn. Wire: B3 F/S Hole: 25Maximum allowable reinforcement: 0.0625"/per sideMaximum reinforcement with DWE/SWV: 0.125" Total of walls + reinforcement: 1.749" 44.4246 mmMaximum reinforcement with DWE/DWV: 0.125" Total of walls + reinforcement: 1.749" 44.4246 mmMaximum reinforcement with SWE/SWV: 0.0625" Total of wall + reinforcement: 0.8745" 22.2123 mm

INADEQUATE PENETRATION WITHOUT HIGH LOWMaximum length of individual indication of IP : 1 inch or 25mmMaximum length of IP in 8% of weld: N/A since total weld exceeds 12 inchesMaximum length of indications in any continuous 12" length of weld: 1" 25 mm

INADEQUATE PENETRATION DUE TO HIGH LOWMaximum length of individual indication of IPD: 2 inches or 50mmMaximum length of indications of IPD in any continuous 12" length of weld: 3" 75 mm

INADEQUATE CROSS PENETRATIONMaximum length of an individual indication of ICP: 2 inches or 50mmMaximum length of indications of ICP in any continuous 12" length of weld: 2" 50 mm

INCOMPLETE FUSIONMaximum length of an individual indication of IF: 1 inch or 25mmMaximum length of IF in 8% of weld: N/A since total weld exceeds 12 inchesMaximum length of indications of IF in any continuous 12" length of weld: 1" 25 mm

INCOMPLETE FUSION DUE TO COLD LAPMaximum length of individual indications of IFD: 2 inches or 50mmMaximum length of IFD in 8% of weld: 55.1193 mmMaximum length of indications of IFD in any continuous 12" length of weld: 2" 25 mm

INTERNAL CONCAVITY Any length of IC is acceptable, provided the density of the radiographic image of the internal concavity does not exceed that of the thinnest adjacent parent material. For areas that exceed the density of thethinnest adjacent parent material, the criteria for burn through are applicable.

BURN - THROUGHMaximum dimension of BT's image : unacceptable if it exceeds that of the thinnest adjacent parent metal.Maximum dimension of BT: 1/4" or 6mmMaximum dimension is unacceptable if: it exceeds the thinner of the nonnal wall thickness joined, and the density

of the BT's image exceeds that of the thinnest adjacent parent material.The sum of the max dimensions of separate BBT's whose image density exceeds that of the thinnest adjacent parentmaterial exceeds 1/2 inch or 13mm in any continuous 12" length of weld or the total weld length(whichever is less).

API - 11048" s/140 - 0.812" Wall

Page 1 of 2

Page 53: NDT Code Book Made Easy

API - 11048" s/140 - 0.812" Wall

SLAG INCLUSIONSElongated slag inclusions (ESI)Maximum length of an ESI: 2 inches or 50mmParallel ESI indications (Wagon Tracks) shall be considered a single indication unless the width of either of them exceed1/32" or 0.8mm. In that event they shall be considered separate indications.Maximum length of ESI indications in any continuous 12" length of weld: 2" 50 mmMaximum width of an individual ESI indication: 1/16" or 1.6mmIsolated slag inclusions (ISI)Maximum length of ISI indications in any continuous 12" length of weld: 1/2" 13 mmMaximum width of an ISI indication: 1/8" or 3mmMaximum length of ESI and ISI in 8% of weld: 55.1193 mm

POROSITY Individual or Scattered Porosity.Maximum size of an individual pore: 1/8" or 3mmThe size of an individual pore exceeds 25% of the thinner of the nonimal wall thickness joined.The distribution of scattered porosity exceeds the concentration permitted in Figures 19 or 20.Cluster Porosity (CP)Maximum diameter of the cluster: 1/2 inch or 13mmMaximum length of CP indications in any continuous 12" length of weweld: 1/2" 13 mmMaximum length of an individual pore within a cluster: 1/16 inch or 2mmHollow Bead Porosity (HB)Maximum length of an individual indication of HB: 1/2 inch or 13mmMaximum length of HB indications in any continuous 12" length of weld: 2" 50 mmMaximum length of HB in 8% of weld: 55.1193 mmNOTE: The weld is unacceptable if individual indications of HB, each greater than 1/4 inch or 6mm in length, are seperated by less than 2 inches or 50 mm.

CRACKSNote: Any crack which is not a shallow crater crack or star crack is unacceptable.Maximum length of shallow crater cracks or star cracks: 5/32 inch or 4mm

UNDERCUTTINGUndercutting adjacent to the cover pass (EU) and Undercutting adjacent to the root pass (IU)Maximum length of EU and IU indications (in any combination) in a 12 inch length of weld: 2" 50 mmMaximum length of EU and IU indications: 4.521 114.8334 mm (This value is 1/6 th of the total weld length)

ACCUMULATION OF IMPERFECTIONSMaximum length of AI indications in any continuous 12 inch or 300 mm length of weld: 2" 50 mmMaximum length of AI indications of 8% of weld: 55.1193 mm

RADIOGRAPHIC INFOPipe O.D. in inches: 8.625"Amount of Penetrameters required for each shot: 1 penetrameter 1" from the end of film and 1 penny in the center.Total weld length: 27.125625" 688.9909 mmCassette size to complete weld in most efficient way: 3.5 x 17" 4.5 x 17"Amount of shots to complete weld with 1" on each side of readable film: 48% of weld: 2.17005" 55.1193 mmHole penetrameters are adjacent to the weld and Wire penetrameters are parallel to the weld.

Page 2 of 2

Page 54: NDT Code Book Made Easy

PENETRAMETER SELECTIONNote: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Wire: 0.016 Esn. Wire: B4 S/S Hole: 20

F/S Wire: 0.013 Esn. Wire: B5 F/S Hole: 17Welds with reinforcement: S/S Wire: 0.020 Esn. Wire: B3 S/S Hole: 25

F/S Wire: 0.016 Esn. Wire: B4 F/S Hole: 20Maximum allowable reinforcement: 0.0625"/per sideMaximum reinforcement with DWE/SWV: 0.125" Total of walls + reinforcement: 1.563" 39.7002 mmMaximum reinforcement with DWE/DWV: 0.125" Total of walls + reinforcement: 1.563" 39.7002 mmMaximum reinforcement with SWE/SWV: 0.0625" Total of wall + reinforcement: 0.782" 19.8628 mm

INADEQUATE PENETRATION WITHOUT HIGH LOWMaximum length of individual indication of IP : 1 inch or 25mmMaximum length of IP in 8% of weld: N/A since total weld exceeds 12 inchesMaximum length of indications in any continuous 12" length of weld: 1" 25 mm

INADEQUATE PENETRATION DUE TO HIGH LOWMaximum length of individual indication of IPD: 2 inches or 50mmMaximum length of indications of IPD in any continuous 12" length of weld: 3" 75 mm

INADEQUATE CROSS PENETRATIONMaximum length of an individual indication of ICP: 2 inches or 50mmMaximum length of indications of ICP in any continuous 12" length of weld: 2" 50 mm

INCOMPLETE FUSIONMaximum length of an individual indication of IF: 1 inch or 25mmMaximum length of IF in 8% of weld: N/A since total weld exceeds 12 inchesMaximum length of indications of IF in any continuous 12" length of weld: 1" 25 mm

INCOMPLETE FUSION DUE TO COLD LAPMaximum length of individual indications of IFD: 2 inches or 50mmMaximum length of IFD in 8% of weld: 55.1193 mmMaximum length of indications of IFD in any continuous 12" length of weld: 2" 25 mm

INTERNAL CONCAVITY Any length of IC is acceptable, provided the density of the radiographic image of the internal concavity does not exceed that of the thinnest adjacent parent material. For areas that exceed the density of thethinnest adjacent parent material, the criteria for burn through are applicable.

BURN - THROUGHMaximum dimension of BT's image : unacceptable if it exceeds that of the thinnest adjacent parent metal.Maximum dimension of BT: 1/4" or 6mmMaximum dimension is unacceptable if: it exceeds the thinner of the nonnal wall thickness joined, and the density

of the BT's image exceeds that of the thinnest adjacent parent material.The sum of the max dimensions of separate BBT's whose image density exceeds that of the thinnest adjacent parentmaterial exceeds 1/2 inch or 13mm in any continuous 12" length of weld or the total weld length(whichever is less).

API - 11048" s/120 - 0.719" Wall

Page 1 of 2

Page 55: NDT Code Book Made Easy

API - 11048" s/120 - 0.719" Wall

SLAG INCLUSIONSElongated slag inclusions (ESI)Maximum length of an ESI: 2 inches or 50mmParallel ESI indications (Wagon Tracks) shall be considered a single indication unless the width of either of them exceed1/32" or 0.8mm. In that event they shall be considered separate indications.Maximum length of ESI indications in any continuous 12" length of weld: 2" 50 mmMaximum width of an individual ESI indication: 1/16" or 1.6mmIsolated slag inclusions (ISI)Maximum length of ISI indications in any continuous 12" length of weld: 1/2" 13 mmMaximum width of an ISI indication: 1/8" or 3mmMaximum length of ESI and ISI in 8% of weld: 55.1193 mm

POROSITY Individual or Scattered Porosity.Maximum size of an individual pore: 1/8" or 3mmThe size of an individual pore exceeds 25% of the thinner of the nonimal wall thickness joined.The distribution of scattered porosity exceeds the concentration permitted in Figures 19 or 20.Cluster Porosity (CP)Maximum diameter of the cluster: 1/2 inch or 13mmMaximum length of CP indications in any continuous 12" length of weweld: 1/2" 13 mmMaximum length of an individual pore within a cluster: 1/16 inch or 2mmHollow Bead Porosity (HB)Maximum length of an individual indication of HB: 1/2 inch or 13mmMaximum length of HB indications in any continuous 12" length of weld: 2" 50 mmMaximum length of HB in 8% of weld: 55.1193 mmNOTE: The weld is unacceptable if individual indications of HB, each greater than 1/4 inch or 6mm in length, are seperated by less than 2 inches or 50 mm.

CRACKSNote: Any crack which is not a shallow crater crack or star crack is unacceptable.Maximum length of shallow crater cracks or star cracks: 5/32 inch or 4mm

UNDERCUTTINGUndercutting adjacent to the cover pass (EU) and Undercutting adjacent to the root pass (IU)Maximum length of EU and IU indications (in any combination) in a 12 inch length of weld: 2" 50 mmMaximum length of EU and IU indications: 4.521 114.8334 mm (This value is 1/6 th of the total weld length)

ACCUMULATION OF IMPERFECTIONSMaximum length of AI indications in any continuous 12 inch or 300 mm length of weld: 2" 50 mmMaximum length of AI indications of 8% of weld: 55.1193 mm

RADIOGRAPHIC INFOPipe O.D. in inches: 8.625"Amount of Penetrameters required for each shot: 1 penetrameter 1" from the end of film and 1 penny in the center.Total weld length: 27.125625" 688.9909 mmCassette size to complete weld in most efficient way: 3.5 x 17" 4.5 x 17"Amount of shots to complete weld with 1" on each side of readable film: 48% of weld: 2.17005" 55.1193 mmHole penetrameters are adjacent to the weld and Wire penetrameters are parallel to the weld.

Page 2 of 2

Page 56: NDT Code Book Made Easy

PENETRAMETER SELECTIONNote: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Wire: 0.020 Esn. Wire: B3 S/S Hole: 25

F/S Wire: 0.016 Esn. Wire: B4 F/S Hole: 20Welds with reinforcement: S/S Wire: 0.025 Esn. Wire: B2 S/S Hole: 30

F/S Wire: 0.020 Esn. Wire: B3 F/S Hole: 25Maximum allowable reinforcement: 0.0625"/per sideMaximum reinforcement with DWE/SWV: 0.125" Total of walls + reinforcement: 1.937" 49.1998 mmMaximum reinforcement with DWE/DWV: 0.125" Total of walls + reinforcement: 1.937" 49.1998 mmMaximum reinforcement with SWE/SWV: 0.0625" Total of wall + reinforcement: 0.9685" 24.5999 mm

INADEQUATE PENETRATION WITHOUT HIGH LOWMaximum length of individual indication of IP : 1 inch or 25mmMaximum length of IP in 8% of weld: N/A since total weld exceeds 12 inchesMaximum length of indications in any continuous 12" length of weld: 1" 25 mm

INADEQUATE PENETRATION DUE TO HIGH LOWMaximum length of individual indication of IPD: 2 inches or 50mmMaximum length of indications of IPD in any continuous 12" length of weld: 3" 75 mm

INADEQUATE CROSS PENETRATIONMaximum length of an individual indication of ICP: 2 inches or 50mmMaximum length of indications of ICP in any continuous 12" length of weld: 2" 50 mm

INCOMPLETE FUSIONMaximum length of an individual indication of IF: 1 inch or 25mmMaximum length of IF in 8% of weld: N/A since total weld exceeds 12 inchesMaximum length of indications of IF in any continuous 12" length of weld: 1" 25 mm

INCOMPLETE FUSION DUE TO COLD LAPMaximum length of individual indications of IFD: 2 inches or 50mmMaximum length of IFD in 8% of weld: 55.1193 mmMaximum length of indications of IFD in any continuous 12" length of weld: 2" 25 mm

INTERNAL CONCAVITY Any length of IC is acceptable, provided the density of the radiographic image of the internal concavity does not exceed that of the thinnest adjacent parent material. For areas that exceed the density of thethinnest adjacent parent material, the criteria for burn through are applicable.

BURN - THROUGHMaximum dimension of BT's image : unacceptable if it exceeds that of the thinnest adjacent parent metal.Maximum dimension of BT: 1/4" or 6mmMaximum dimension is unacceptable if: it exceeds the thinner of the nonnal wall thickness joined, and the density

of the BT's image exceeds that of the thinnest adjacent parent material.The sum of the max dimensions of separate BBT's whose image density exceeds that of the thinnest adjacent parentmaterial exceeds 1/2 inch or 13mm in any continuous 12" length of weld or the total weld length(whichever is less).

API - 11048" s/160 - 0.906" Wall

Page 1 of 2

Page 57: NDT Code Book Made Easy

API - 11048" s/160 - 0.906" Wall

SLAG INCLUSIONSElongated slag inclusions (ESI)Maximum length of an ESI: 2 inches or 50mmParallel ESI indications (Wagon Tracks) shall be considered a single indication unless the width of either of them exceed1/32" or 0.8mm. In that event they shall be considered separate indications.Maximum length of ESI indications in any continuous 12" length of weld: 2" 50 mmMaximum width of an individual ESI indication: 1/16" or 1.6mmIsolated slag inclusions (ISI)Maximum length of ISI indications in any continuous 12" length of weld: 1/2" 13 mmMaximum width of an ISI indication: 1/8" or 3mmMaximum length of ESI and ISI in 8% of weld: 55.1193 mm

POROSITY Individual or Scattered Porosity.Maximum size of an individual pore: 1/8" or 3mmThe size of an individual pore exceeds 25% of the thinner of the nonimal wall thickness joined.The distribution of scattered porosity exceeds the concentration permitted in Figures 19 or 20.Cluster Porosity (CP)Maximum diameter of the cluster: 1/2 inch or 13mmMaximum length of CP indications in any continuous 12" length of weweld: 1/2" 13 mmMaximum length of an individual pore within a cluster: 1/16 inch or 2mmHollow Bead Porosity (HB)Maximum length of an individual indication of HB: 1/2 inch or 13mmMaximum length of HB indications in any continuous 12" length of weld: 2" 50 mmMaximum length of HB in 8% of weld: 55.1193 mmNOTE: The weld is unacceptable if individual indications of HB, each greater than 1/4 inch or 6mm in length, are seperated by less than 2 inches or 50 mm.

CRACKSNote: Any crack which is not a shallow crater crack or star crack is unacceptable.Maximum length of shallow crater cracks or star cracks: 5/32 inch or 4mm

UNDERCUTTINGUndercutting adjacent to the cover pass (EU) and Undercutting adjacent to the root pass (IU)Maximum length of EU and IU indications (in any combination) in a 12 inch length of weld: 2" 50 mmMaximum length of EU and IU indications: 4.521 114.8334 mm (This value is 1/6 th of the total weld length)

ACCUMULATION OF IMPERFECTIONSMaximum length of AI indications in any continuous 12 inch or 300 mm length of weld: 2" 50 mmMaximum length of AI indications of 8% of weld: 55.1193 mm

RADIOGRAPHIC INFOPipe O.D. in inches: 8.625"Amount of Penetrameters required for each shot: 1 penetrameter 1" from the end of film and 1 penny in the center.Total weld length: 27.125625" 688.9909 mmCassette size to complete weld in most efficient way: 3.5 x 17" 4.5 x 17"Amount of shots to complete weld with 1" on each side of readable film: 48% of weld: 2.17005" 55.1193 mmHole penetrameters are adjacent to the weld and Wire penetrameters are parallel to the weld.

Page 2 of 2

Page 58: NDT Code Book Made Easy

PENETRAMETER SELECTIONNote: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Wire: 0.020 Esn. Wire: B3 S/S Hole: 25

F/S Wire: 0.016 Esn. Wire: B4 F/S Hole: 20Welds with reinforcement: S/S Wire: 0.025 Esn. Wire: B2 S/S Hole: 30

F/S Wire: 0.020 Esn. Wire: B3 F/S Hole: 25Maximum allowable reinforcement: 0.0625"/per sideMaximum reinforcement with DWE/SWV: 0.125" Total of walls + reinforcement: 1.875" 47.6250 mmMaximum reinforcement with DWE/DWV: 0.125" Total of walls + reinforcement: 1.875" 47.6250 mmMaximum reinforcement with SWE/SWV: 0.0625" Total of wall + reinforcement: 0.9375" 23.8125 mm

INADEQUATE PENETRATION WITHOUT HIGH LOWMaximum length of individual indication of IP : 1 inch or 25mmMaximum length of IP in 8% of weld: N/A since total weld exceeds 12 inchesMaximum length of indications in any continuous 12" length of weld: 1" 25 mm

INADEQUATE PENETRATION DUE TO HIGH LOWMaximum length of individual indication of IPD: 2 inches or 50mmMaximum length of indications of IPD in any continuous 12" length of weld: 3" 75 mm

INADEQUATE CROSS PENETRATIONMaximum length of an individual indication of ICP: 2 inches or 50mmMaximum length of indications of ICP in any continuous 12" length of weld: 2" 50 mm

INCOMPLETE FUSIONMaximum length of an individual indication of IF: 1 inch or 25mmMaximum length of IF in 8% of weld: N/A since total weld exceeds 12 inchesMaximum length of indications of IF in any continuous 12" length of weld: 1" 25 mm

INCOMPLETE FUSION DUE TO COLD LAPMaximum length of individual indications of IFD: 2 inches or 50mmMaximum length of IFD in 8% of weld: 55.1193 mmMaximum length of indications of IFD in any continuous 12" length of weld: 2" 25 mm

INTERNAL CONCAVITY Any length of IC is acceptable, provided the density of the radiographic image of the internal concavity does not exceed that of the thinnest adjacent parent material. For areas that exceed the density of thethinnest adjacent parent material, the criteria for burn through are applicable.

BURN - THROUGHMaximum dimension of BT's image : unacceptable if it exceeds that of the thinnest adjacent parent metal.Maximum dimension of BT: 1/4" or 6mmMaximum dimension is unacceptable if: it exceeds the thinner of the nonnal wall thickness joined, and the density

of the BT's image exceeds that of the thinnest adjacent parent material.The sum of the max dimensions of separate BBT's whose image density exceeds that of the thinnest adjacent parentmaterial exceeds 1/2 inch or 13mm in any continuous 12" length of weld or the total weld length(whichever is less).

API - 11048" XX Strong - 0.875" Wall

Page 1 of 2

Page 59: NDT Code Book Made Easy

API - 11048" XX Strong - 0.875" Wall

SLAG INCLUSIONSElongated slag inclusions (ESI)Maximum length of an ESI: 2 inches or 50mmParallel ESI indications (Wagon Tracks) shall be considered a single indication unless the width of either of them exceed1/32" or 0.8mm. In that event they shall be considered separate indications.Maximum length of ESI indications in any continuous 12" length of weld: 2" 50 mmMaximum width of an individual ESI indication: 1/16" or 1.6mmIsolated slag inclusions (ISI)Maximum length of ISI indications in any continuous 12" length of weld: 1/2" 13 mmMaximum width of an ISI indication: 1/8" or 3mmMaximum length of ESI and ISI in 8% of weld: 55.1193 mm

POROSITY Individual or Scattered Porosity.Maximum size of an individual pore: 1/8" or 3mmThe size of an individual pore exceeds 25% of the thinner of the nonimal wall thickness joined.The distribution of scattered porosity exceeds the concentration permitted in Figures 19 or 20.Cluster Porosity (CP)Maximum diameter of the cluster: 1/2 inch or 13mmMaximum length of CP indications in any continuous 12" length of weweld: 1/2" 13 mmMaximum length of an individual pore within a cluster: 1/16 inch or 2mmHollow Bead Porosity (HB)Maximum length of an individual indication of HB: 1/2 inch or 13mmMaximum length of HB indications in any continuous 12" length of weld: 2" 50 mmMaximum length of HB in 8% of weld: 55.1193 mmNOTE: The weld is unacceptable if individual indications of HB, each greater than 1/4 inch or 6mm in length, are seperated by less than 2 inches or 50 mm.

CRACKSNote: Any crack which is not a shallow crater crack or star crack is unacceptable.Maximum length of shallow crater cracks or star cracks: 5/32 inch or 4mm

UNDERCUTTINGUndercutting adjacent to the cover pass (EU) and Undercutting adjacent to the root pass (IU)Maximum length of EU and IU indications (in any combination) in a 12 inch length of weld: 2" 50 mmMaximum length of EU and IU indications: 4.521 114.8334 mm (This value is 1/6 th of the total weld length)

ACCUMULATION OF IMPERFECTIONSMaximum length of AI indications in any continuous 12 inch or 300 mm length of weld: 2" 50 mmMaximum length of AI indications of 8% of weld: 55.1193 mm

RADIOGRAPHIC INFOPipe O.D. in inches: 8.625"Amount of Penetrameters required for each shot: 1 penetrameter 1" from the end of film and 1 penny in the center.Total weld length: 27.125625" 688.9909 mmCassette size to complete weld in most efficient way: 3.5 x 17" 4.5 x 17"Amount of shots to complete weld with 1" on each side of readable film: 58% of weld: 2.17005" 55.1193 mmHole penetrameters are adjacent to the weld and Wire penetrameters are parallel to the weld.

Page 2 of 2

Page 60: NDT Code Book Made Easy

PENETRAMETER SELECTIONNote: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Wire: 0.008 Esn. Wire: A2 S/S Hole: 12

F/S Wire: 0.006 Esn. Wire: A3 F/S Hole: 10Welds with reinforcement: S/S Wire: 0.008 Esn. Wire: A2 S/S Hole: 12

F/S Wire: 0.006 Esn. Wire: A3 F/S Hole: 10Maximum allowable reinforcement: 0.0625"/per sideMaximum reinforcement with DWE/SWV: 0.125" Total of walls + reinforcement: 0.455" 11.5570 mmMaximum reinforcement with DWE/DWV: 0.125" Total of walls + reinforcement: 0.455" 11.5570 mmMaximum reinforcement with SWE/SWV: 0.0625" Total of wall + reinforcement: 0.2275" 5.7785 mm

INADEQUATE PENETRATION WITHOUT HIGH LOWMaximum length of individual indication of IP : 1 inch or 25mmMaximum length of IP in 8% of weld: N/A since total weld exceeds 12 inchesMaximum length of indications in any continuous 12" length of weld: 1" 25 mm

INADEQUATE PENETRATION DUE TO HIGH LOWMaximum length of individual indication of IPD: 2 inches or 50mmMaximum length of indications of IPD in any continuous 12" length of weld: 3" 75 mm

INADEQUATE CROSS PENETRATIONMaximum length of an individual indication of ICP: 2 inches or 50mmMaximum length of indications of ICP in any continuous 12" length of weld: 2" 50 mm

INCOMPLETE FUSIONMaximum length of an individual indication of IF: 1 inch or 25mmMaximum length of IF in 8% of weld: N/A since total weld exceeds 12 inchesMaximum length of indications of IF in any continuous 12" length of weld: 1" 25 mm

INCOMPLETE FUSION DUE TO COLD LAPMaximum length of individual indications of IFD: 2 inches or 50mmMaximum length of IFD in 8% of weld: 68.6994 mmMaximum length of indications of IFD in any continuous 12" length of weld: 2" 25 mm

INTERNAL CONCAVITY Any length of IC is acceptable, provided the density of the radiographic image of the internal concavity does not exceed that of the thinnest adjacent parent material. For areas that exceed the density of thethinnest adjacent parent material, the criteria for burn through are applicable.

BURN - THROUGHMaximum dimension of BT's image : unacceptable if it exceeds that of the thinnest adjacent parent metal.Maximum dimension of BT: 1/4" or 6mmMaximum dimension is unacceptable if: it exceeds the thinner of the nonnal wall thickness joined, and the density

of the BT's image exceeds that of the thinnest adjacent parent material.The sum of the max dimensions of separate BBT's whose image density exceeds that of the thinnest adjacent parentmaterial exceeds 1/2 inch or 13mm in any continuous 12" length of weld or the total weld length(whichever is less).

API - 110410" s/10 - 0.165" Wall

Page 1 of 2

Page 61: NDT Code Book Made Easy

API - 110410" s/10 - 0.165" Wall

SLAG INCLUSIONSElongated slag inclusions (ESI)Maximum length of an ESI: 2 inches or 50mmParallel ESI indications (Wagon Tracks) shall be considered a single indication unless the width of either of them exceed1/32" or 0.8mm. In that event they shall be considered separate indications.Maximum length of ESI indications in any continuous 12" length of weld: 2" 50 mmMaximum width of an individual ESI indication: 1/16" or 1.6mmIsolated slag inclusions (ISI)Maximum length of ISI indications in any continuous 12" length of weld: 1/2" 13 mmMaximum width of an ISI indication: 1/8" or 3mmMaximum length of ESI and ISI in 8% of weld: 68.6994 mm

POROSITY Individual or Scattered Porosity.Maximum size of an individual pore: 1/8" or 3mmThe size of an individual pore exceeds 25% of the thinner of the nonimal wall thickness joined.The distribution of scattered porosity exceeds the concentration permitted in Figures 19 or 20.Cluster Porosity (CP)Maximum diameter of the cluster: 1/2 inch or 13mmMaximum length of CP indications in any continuous 12" length of weweld: 1/2" 13 mmMaximum length of an individual pore within a cluster: 1/16 inch or 2mmHollow Bead Porosity (HB)Maximum length of an individual indication of HB: 1/2 inch or 13mmMaximum length of HB indications in any continuous 12" length of weld: 2" 50 mmMaximum length of HB in 8% of weld: 68.6994 mmNOTE: The weld is unacceptable if individual indications of HB, each greater than 1/4 inch or 6mm in length, are seperated by less than 2 inches or 50 mm.

CRACKSNote: Any crack which is not a shallow crater crack or star crack is unacceptable.Maximum length of shallow crater cracks or star cracks: 5/32 inch or 4mm

UNDERCUTTINGUndercutting adjacent to the cover pass (EU) and Undercutting adjacent to the root pass (IU)Maximum length of EU and IU indications (in any combination) in a 12 inch length of weld: 2" 50 mmMaximum length of EU and IU indications: 5.635" 143.1290 mm (This value is 1/6 th of the total weld length)

ACCUMULATION OF IMPERFECTIONSMaximum length of AI indications in any continuous 12 inch or 300 mm length of weld: 2" 50 mmMaximum length of AI indications of 8% of weld: 68.6994 mm

RADIOGRAPHIC INFOPipe O.D. in inches: 10.750"Amount of Penetrameters required for each shot: 1 penetrameter 1" from the end of film and 1 penny in the center.Total weld length: 33.80875" 858.7105 mmCassette size to complete weld in most efficient way: 3.5 x 17" 4.5 x 17"Amount of shots to complete weld with 1" on each side of readable film: 38% of weld: 2.7047" 68.6994 mmHole penetrameters are adjacent to the weld and Wire penetrameters are parallel to the weld.

Page 2 of 2

Page 62: NDT Code Book Made Easy

PENETRAMETER SELECTIONNote: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Wire: 0.010 Esn. Wire: A1 or B6 S/S Hole: 15

F/S Wire: 0.008 Esn. Wire: A2 F/S Hole: 12Welds with reinforcement: S/S Wire: 0.013 Esn. Wire: B5 S/S Hole: 17

F/S Wire: 0.010 Esn. Wire: A1 or B6 F/S Hole: 15Maximum allowable reinforcement: 0.0625"/per sideMaximum reinforcement with DWE/SWV: 0.125" Total of walls + reinforcement: 0.855" 21.7170 mmMaximum reinforcement with DWE/DWV: 0.125" Total of walls + reinforcement: 0.855" 21.7170 mmMaximum reinforcement with SWE/SWV: 0.0625" Total of wall + reinforcement: 0.4275" 10.8585 mm

INADEQUATE PENETRATION WITHOUT HIGH LOWMaximum length of individual indication of IP : 1 inch or 25mmMaximum length of IP in 8% of weld: N/A since total weld exceeds 12 inchesMaximum length of indications in any continuous 12" length of weld: 1" 25 mm

INADEQUATE PENETRATION DUE TO HIGH LOWMaximum length of individual indication of IPD: 2 inches or 50mmMaximum length of indications of IPD in any continuous 12" length of weld: 3" 75 mm

INADEQUATE CROSS PENETRATIONMaximum length of an individual indication of ICP: 2 inches or 50mmMaximum length of indications of ICP in any continuous 12" length of weld: 2" 50 mm

INCOMPLETE FUSIONMaximum length of an individual indication of IF: 1 inch or 25mmMaximum length of IF in 8% of weld: N/A since total weld exceeds 12 inchesMaximum length of indications of IF in any continuous 12" length of weld: 1" 25 mm

INCOMPLETE FUSION DUE TO COLD LAPMaximum length of individual indications of IFD: 2 inches or 50mmMaximum length of IFD in 8% of weld: 68.6994 mmMaximum length of indications of IFD in any continuous 12" length of weld: 2" 25 mm

INTERNAL CONCAVITY Any length of IC is acceptable, provided the density of the radiographic image of the internal concavity does not exceed that of the thinnest adjacent parent material. For areas that exceed the density of thethinnest adjacent parent material, the criteria for burn through are applicable.

BURN - THROUGHMaximum dimension of BT's image : unacceptable if it exceeds that of the thinnest adjacent parent metal.Maximum dimension of BT: 1/4" or 6mmMaximum dimension is unacceptable if: it exceeds the thinner of the nonnal wall thickness joined, and the density

of the BT's image exceeds that of the thinnest adjacent parent material.The sum of the max dimensions of separate BBT's whose image density exceeds that of the thinnest adjacent parentmaterial exceeds 1/2 inch or 13mm in any continuous 12" length of weld or the total weld length(whichever is less).

API - 110410" s/40 & Std. - 0.365" Wall

Page 1 of 2

Page 63: NDT Code Book Made Easy

API - 110410" s/40 & Std. - 0.365" Wall

SLAG INCLUSIONSElongated slag inclusions (ESI)Maximum length of an ESI: 2 inches or 50mmParallel ESI indications (Wagon Tracks) shall be considered a single indication unless the width of either of them exceed1/32" or 0.8mm. In that event they shall be considered separate indications.Maximum length of ESI indications in any continuous 12" length of weld: 2" 50 mmMaximum width of an individual ESI indication: 1/16" or 1.6mmIsolated slag inclusions (ISI)Maximum length of ISI indications in any continuous 12" length of weld: 1/2" 13 mmMaximum width of an ISI indication: 1/8" or 3mmMaximum length of ESI and ISI in 8% of weld: 68.6994 mm

POROSITY Individual or Scattered Porosity.Maximum size of an individual pore: 1/8" or 3mmThe size of an individual pore exceeds 25% of the thinner of the nonimal wall thickness joined.The distribution of scattered porosity exceeds the concentration permitted in Figures 19 or 20.Cluster Porosity (CP)Maximum diameter of the cluster: 1/2 inch or 13mmMaximum length of CP indications in any continuous 12" length of weweld: 1/2" 13 mmMaximum length of an individual pore within a cluster: 1/16 inch or 2mmHollow Bead Porosity (HB)Maximum length of an individual indication of HB: 1/2 inch or 13mmMaximum length of HB indications in any continuous 12" length of weld: 2" 50 mmMaximum length of HB in 8% of weld: 68.6994 mmNOTE: The weld is unacceptable if individual indications of HB, each greater than 1/4 inch or 6mm in length, are seperated by less than 2 inches or 50 mm.

CRACKSNote: Any crack which is not a shallow crater crack or star crack is unacceptable.Maximum length of shallow crater cracks or star cracks: 5/32 inch or 4mm

UNDERCUTTINGUndercutting adjacent to the cover pass (EU) and Undercutting adjacent to the root pass (IU)Maximum length of EU and IU indications (in any combination) in a 12 inch length of weld: 2" 50 mmMaximum length of EU and IU indications: 5.635" 143.1290 mm (This value is 1/6 th of the total weld length)

ACCUMULATION OF IMPERFECTIONSMaximum length of AI indications in any continuous 12 inch or 300 mm length of weld: 2" 50 mmMaximum length of AI indications of 8% of weld: 68.6994 mm

RADIOGRAPHIC INFOPipe O.D. in inches: 10.750"Amount of Penetrameters required for each shot: 1 penetrameter 1" from the end of film and 1 penny in the center.Total weld length: 33.80875" 858.7105 mmCassette size to complete weld in most efficient way: 3.5 x 17" 4.5 x 17"Amount of shots to complete weld with 1" on each side of readable film: 38% of weld: 2.7047" 68.6994 mmHole penetrameters are adjacent to the weld and Wire penetrameters are parallel to the weld.

Page 2 of 2

Page 64: NDT Code Book Made Easy

PENETRAMETER SELECTIONNote: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Wire: 0.016 Esn. Wire: B4 S/S Hole: 20

F/S Wire: 0.013 Esn. Wire: B5 F/S Hole: 17Welds with reinforcement: S/S Wire: 0.016 Esn. Wire: B4 S/S Hole: 20

F/S Wire: 0.013 Esn. Wire: B5 F/S Hole: 17Maximum allowable reinforcement: 0.0625"/per sideMaximum reinforcement with DWE/SWV: 0.125" Total of walls + reinforcement: 1.313" 33.3502 mmMaximum reinforcement with DWE/DWV: 0.125" Total of walls + reinforcement: 1.313" 33.3502 mmMaximum reinforcement with SWE/SWV: 0.0625" Total of wall + reinforcement: 0.6565" 16.6751 mm

INADEQUATE PENETRATION WITHOUT HIGH LOWMaximum length of individual indication of IP : 1 inch or 25mmMaximum length of IP in 8% of weld: N/A since total weld exceeds 12 inchesMaximum length of indications in any continuous 12" length of weld: 1" 25 mm

INADEQUATE PENETRATION DUE TO HIGH LOWMaximum length of individual indication of IPD: 2 inches or 50mmMaximum length of indications of IPD in any continuous 12" length of weld: 3" 75 mm

INADEQUATE CROSS PENETRATIONMaximum length of an individual indication of ICP: 2 inches or 50mmMaximum length of indications of ICP in any continuous 12" length of weld: 2" 50 mm

INCOMPLETE FUSIONMaximum length of an individual indication of IF: 1 inch or 25mmMaximum length of IF in 8% of weld: N/A since total weld exceeds 12 inchesMaximum length of indications of IF in any continuous 12" length of weld: 1" 25 mm

INCOMPLETE FUSION DUE TO COLD LAPMaximum length of individual indications of IFD: 2 inches or 50mmMaximum length of IFD in 8% of weld: 68.6994 mmMaximum length of indications of IFD in any continuous 12" length of weld: 2" 25 mm

INTERNAL CONCAVITY Any length of IC is acceptable, provided the density of the radiographic image of the internal concavity does not exceed that of the thinnest adjacent parent material. For areas that exceed the density of thethinnest adjacent parent material, the criteria for burn through are applicable.

BURN - THROUGHMaximum dimension of BT's image : unacceptable if it exceeds that of the thinnest adjacent parent metal.Maximum dimension of BT: 1/4" or 6mmMaximum dimension is unacceptable if: it exceeds the thinner of the nonnal wall thickness joined, and the density

of the BT's image exceeds that of the thinnest adjacent parent material.The sum of the max dimensions of separate BBT's whose image density exceeds that of the thinnest adjacent parentmaterial exceeds 1/2 inch or 13mm in any continuous 12" length of weld or the total weld length(whichever is less).

API - 110410" s/80 - 0.594" Wall

Page 1 of 2

Page 65: NDT Code Book Made Easy

API - 110410" s/80 - 0.594" Wall

SLAG INCLUSIONSElongated slag inclusions (ESI)Maximum length of an ESI: 2 inches or 50mmParallel ESI indications (Wagon Tracks) shall be considered a single indication unless the width of either of them exceed1/32" or 0.8mm. In that event they shall be considered separate indications.Maximum length of ESI indications in any continuous 12" length of weld: 2" 50 mmMaximum width of an individual ESI indication: 1/16" or 1.6mmIsolated slag inclusions (ISI)Maximum length of ISI indications in any continuous 12" length of weld: 1/2" 13 mmMaximum width of an ISI indication: 1/8" or 3mmMaximum length of ESI and ISI in 8% of weld: 68.6994 mm

POROSITY Individual or Scattered Porosity.Maximum size of an individual pore: 1/8" or 3mmThe size of an individual pore exceeds 25% of the thinner of the nonimal wall thickness joined.The distribution of scattered porosity exceeds the concentration permitted in Figures 19 or 20.Cluster Porosity (CP)Maximum diameter of the cluster: 1/2 inch or 13mmMaximum length of CP indications in any continuous 12" length of weweld: 1/2" 13 mmMaximum length of an individual pore within a cluster: 1/16 inch or 2mmHollow Bead Porosity (HB)Maximum length of an individual indication of HB: 1/2 inch or 13mmMaximum length of HB indications in any continuous 12" length of weld: 2" 50 mmMaximum length of HB in 8% of weld: 68.6994 mmNOTE: The weld is unacceptable if individual indications of HB, each greater than 1/4 inch or 6mm in length, are seperated by less than 2 inches or 50 mm.

CRACKSNote: Any crack which is not a shallow crater crack or star crack is unacceptable.Maximum length of shallow crater cracks or star cracks: 5/32 inch or 4mm

UNDERCUTTINGUndercutting adjacent to the cover pass (EU) and Undercutting adjacent to the root pass (IU)Maximum length of EU and IU indications (in any combination) in a 12 inch length of weld: 2" 50 mmMaximum length of EU and IU indications: 5.635" 143.1290 mm (This value is 1/6 th of the total weld length)

ACCUMULATION OF IMPERFECTIONSMaximum length of AI indications in any continuous 12 inch or 300 mm length of weld: 2" 50 mmMaximum length of AI indications of 8% of weld: 68.6994 mm

RADIOGRAPHIC INFOPipe O.D. in inches: 10.750"Amount of Penetrameters required for each shot: 1 penetrameter 1" from the end of film and 1 penny in the center.Total weld length: 33.80875" 858.7105 mmCassette size to complete weld in most efficient way: 3.5 x 17" 4.5 x 17"Amount of shots to complete weld with 1" on each side of readable film: 38% of weld: 2.7047" 68.6994 mmHole penetrameters are adjacent to the weld and Wire penetrameters are parallel to the weld.

Page 2 of 2

Page 66: NDT Code Book Made Easy

PENETRAMETER SELECTIONNote: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Wire: 0.020 Esn. Wire: B3 S/S Hole: 25

F/S Wire: 0.016 Esn. Wire: B4 F/S Hole: 20Welds with reinforcement: S/S Wire: 0.025 Esn. Wire: B2 S/S Hole: 30

F/S Wire: 0.020 Esn. Wire: B3 F/S Hole: 25Maximum allowable reinforcement: 0.0625"/per sideMaximum reinforcement with DWE/SWV: 0.125" Total of walls + reinforcement: 1.811" 45.9994 mmMaximum reinforcement with DWE/DWV: 0.125" Total of walls + reinforcement: 1.811" 45.9994 mmMaximum reinforcement with SWE/SWV: 0.0625" Total of wall + reinforcement: 0.9055" 22.9997 mm

INADEQUATE PENETRATION WITHOUT HIGH LOWMaximum length of individual indication of IP : 1 inch or 25mmMaximum length of IP in 8% of weld: N/A since total weld exceeds 12 inchesMaximum length of indications in any continuous 12" length of weld: 1" 25 mm

INADEQUATE PENETRATION DUE TO HIGH LOWMaximum length of individual indication of IPD: 2 inches or 50mmMaximum length of indications of IPD in any continuous 12" length of weld: 3" 75 mm

INADEQUATE CROSS PENETRATIONMaximum length of an individual indication of ICP: 2 inches or 50mmMaximum length of indications of ICP in any continuous 12" length of weld: 2" 50 mm

INCOMPLETE FUSIONMaximum length of an individual indication of IF: 1 inch or 25mmMaximum length of IF in 8% of weld: N/A since total weld exceeds 12 inchesMaximum length of indications of IF in any continuous 12" length of weld: 1" 25 mm

INCOMPLETE FUSION DUE TO COLD LAPMaximum length of individual indications of IFD: 2 inches or 50mmMaximum length of IFD in 8% of weld: 68.6994 mmMaximum length of indications of IFD in any continuous 12" length of weld: 2" 25 mm

INTERNAL CONCAVITY Any length of IC is acceptable, provided the density of the radiographic image of the internal concavity does not exceed that of the thinnest adjacent parent material. For areas that exceed the density of thethinnest adjacent parent material, the criteria for burn through are applicable.

BURN - THROUGHMaximum dimension of BT's image : unacceptable if it exceeds that of the thinnest adjacent parent metal.Maximum dimension of BT: 1/4" or 6mmMaximum dimension is unacceptable if: it exceeds the thinner of the nonnal wall thickness joined, and the density

of the BT's image exceeds that of the thinnest adjacent parent material.The sum of the max dimensions of separate BBT's whose image density exceeds that of the thinnest adjacent parentmaterial exceeds 1/2 inch or 13mm in any continuous 12" length of weld or the total weld length(whichever is less).

API - 110410" s/120 - 0.843" Wall

Page 1 of 2

Page 67: NDT Code Book Made Easy

API - 110410" s/120 - 0.843" Wall

SLAG INCLUSIONSElongated slag inclusions (ESI)Maximum length of an ESI: 2 inches or 50mmParallel ESI indications (Wagon Tracks) shall be considered a single indication unless the width of either of them exceed1/32" or 0.8mm. In that event they shall be considered separate indications.Maximum length of ESI indications in any continuous 12" length of weld: 2" 50 mmMaximum width of an individual ESI indication: 1/16" or 1.6mmIsolated slag inclusions (ISI)Maximum length of ISI indications in any continuous 12" length of weld: 1/2" 13 mmMaximum width of an ISI indication: 1/8" or 3mmMaximum length of ESI and ISI in 8% of weld: 68.6994 mm

POROSITY Individual or Scattered Porosity.Maximum size of an individual pore: 1/8" or 3mmThe size of an individual pore exceeds 25% of the thinner of the nonimal wall thickness joined.The distribution of scattered porosity exceeds the concentration permitted in Figures 19 or 20.Cluster Porosity (CP)Maximum diameter of the cluster: 1/2 inch or 13mmMaximum length of CP indications in any continuous 12" length of weweld: 1/2" 13 mmMaximum length of an individual pore within a cluster: 1/16 inch or 2mmHollow Bead Porosity (HB)Maximum length of an individual indication of HB: 1/2 inch or 13mmMaximum length of HB indications in any continuous 12" length of weld: 2" 50 mmMaximum length of HB in 8% of weld: 68.6994 mmNOTE: The weld is unacceptable if individual indications of HB, each greater than 1/4 inch or 6mm in length, are seperated by less than 2 inches or 50 mm.

CRACKSNote: Any crack which is not a shallow crater crack or star crack is unacceptable.Maximum length of shallow crater cracks or star cracks: 5/32 inch or 4mm

UNDERCUTTINGUndercutting adjacent to the cover pass (EU) and Undercutting adjacent to the root pass (IU)Maximum length of EU and IU indications (in any combination) in a 12 inch length of weld: 2" 50 mmMaximum length of EU and IU indications: 5.635" 143.1290 mm (This value is 1/6 th of the total weld length)

ACCUMULATION OF IMPERFECTIONSMaximum length of AI indications in any continuous 12 inch or 300 mm length of weld: 2" 50 mmMaximum length of AI indications of 8% of weld: 68.6994 mm

RADIOGRAPHIC INFOPipe O.D. in inches: 10.750"Amount of Penetrameters required for each shot: 1 penetrameter 1" from the end of film and 1 penny in the center.Total weld length: 33.80875" 858.7105 mmCassette size to complete weld in most efficient way: 3.5 x 17" 4.5 x 17"Amount of shots to complete weld with 1" on each side of readable film: 38% of weld: 2.7047" 68.6994 mmHole penetrameters are adjacent to the weld and Wire penetrameters are parallel to the weld.

Page 2 of 2

Page 68: NDT Code Book Made Easy

PENETRAMETER SELECTIONNote: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Wire: 0.013 Esn. Wire: B5 S/S Hole: 17

F/S Wire: 0.010 Esn. Wire: A1 or B6 F/S Hole: 15Welds with reinforcement: S/S Wire: 0.016 Esn. Wire: B4 S/S Hole: 20

F/S Wire: 0.013 Esn. Wire: B5 F/S Hole: 17Maximum allowable reinforcement: 0.0625"/per sideMaximum reinforcement with DWE/SWV: 0.125" Total of walls + reinforcement: 1.125" 28.5750 mmMaximum reinforcement with DWE/DWV: 0.125" Total of walls + reinforcement: 1.125" 28.5750 mmMaximum reinforcement with SWE/SWV: 0.0625" Total of wall + reinforcement: 0.5625" 14.2875 mm

INADEQUATE PENETRATION WITHOUT HIGH LOWMaximum length of individual indication of IP : 1 inch or 25mmMaximum length of IP in 8% of weld: N/A since total weld exceeds 12 inchesMaximum length of indications in any continuous 12" length of weld: 1" 25 mm

INADEQUATE PENETRATION DUE TO HIGH LOWMaximum length of individual indication of IPD: 2 inches or 50mmMaximum length of indications of IPD in any continuous 12" length of weld: 3" 75 mm

INADEQUATE CROSS PENETRATIONMaximum length of an individual indication of ICP: 2 inches or 50mmMaximum length of indications of ICP in any continuous 12" length of weld: 2" 50 mm

INCOMPLETE FUSIONMaximum length of an individual indication of IF: 1 inch or 25mmMaximum length of IF in 8% of weld: N/A since total weld exceeds 12 inchesMaximum length of indications of IF in any continuous 12" length of weld: 1" 25 mm

INCOMPLETE FUSION DUE TO COLD LAPMaximum length of individual indications of IFD: 2 inches or 50mmMaximum length of IFD in 8% of weld: 68.6994 mmMaximum length of indications of IFD in any continuous 12" length of weld: 2" 25 mm

INTERNAL CONCAVITY Any length of IC is acceptable, provided the density of the radiographic image of the internal concavity does not exceed that of the thinnest adjacent parent material. For areas that exceed the density of thethinnest adjacent parent material, the criteria for burn through are applicable.

BURN - THROUGHMaximum dimension of BT's image : unacceptable if it exceeds that of the thinnest adjacent parent metal.Maximum dimension of BT: 1/4" or 6mmMaximum dimension is unacceptable if: it exceeds the thinner of the nonnal wall thickness joined, and the density

of the BT's image exceeds that of the thinnest adjacent parent material.The sum of the max dimensions of separate BBT's whose image density exceeds that of the thinnest adjacent parentmaterial exceeds 1/2 inch or 13mm in any continuous 12" length of weld or the total weld length(whichever is less).

API - 110410" Extra Strong - 0.500" Wall

Page 1 of 2

Page 69: NDT Code Book Made Easy

API - 110410" Extra Strong - 0.500" Wall

SLAG INCLUSIONSElongated slag inclusions (ESI)Maximum length of an ESI: 2 inches or 50mmParallel ESI indications (Wagon Tracks) shall be considered a single indication unless the width of either of them exceed1/32" or 0.8mm. In that event they shall be considered separate indications.Maximum length of ESI indications in any continuous 12" length of weld: 2" 50 mmMaximum width of an individual ESI indication: 1/16" or 1.6mmIsolated slag inclusions (ISI)Maximum length of ISI indications in any continuous 12" length of weld: 1/2" 13 mmMaximum width of an ISI indication: 1/8" or 3mmMaximum length of ESI and ISI in 8% of weld: 68.6994 mm

POROSITY Individual or Scattered Porosity.Maximum size of an individual pore: 1/8" or 3mmThe size of an individual pore exceeds 25% of the thinner of the nonimal wall thickness joined.The distribution of scattered porosity exceeds the concentration permitted in Figures 19 or 20.Cluster Porosity (CP)Maximum diameter of the cluster: 1/2 inch or 13mmMaximum length of CP indications in any continuous 12" length of weweld: 1/2" 13 mmMaximum length of an individual pore within a cluster: 1/16 inch or 2mmHollow Bead Porosity (HB)Maximum length of an individual indication of HB: 1/2 inch or 13mmMaximum length of HB indications in any continuous 12" length of weld: 2" 50 mmMaximum length of HB in 8% of weld: 68.6994 mmNOTE: The weld is unacceptable if individual indications of HB, each greater than 1/4 inch or 6mm in length, are seperated by less than 2 inches or 50 mm.

CRACKSNote: Any crack which is not a shallow crater crack or star crack is unacceptable.Maximum length of shallow crater cracks or star cracks: 5/32 inch or 4mm

UNDERCUTTINGUndercutting adjacent to the cover pass (EU) and Undercutting adjacent to the root pass (IU)Maximum length of EU and IU indications (in any combination) in a 12 inch length of weld: 2" 50 mmMaximum length of EU and IU indications: 5.635" 143.1290 mm (This value is 1/6 th of the total weld length)

ACCUMULATION OF IMPERFECTIONSMaximum length of AI indications in any continuous 12 inch or 300 mm length of weld: 2" 50 mmMaximum length of AI indications of 8% of weld: 68.6994 mm

RADIOGRAPHIC INFOPipe O.D. in inches: 10.750"Amount of Penetrameters required for each shot: 1 penetrameter 1" from the end of film and 1 penny in the center.Total weld length: 33.80875" 858.7105 mmCassette size to complete weld in most efficient way: 3.5 x 17" 4.5 x 17"Amount of shots to complete weld with 1" on each side of readable film: 38% of weld: 2.7047" 68.6994 mmHole penetrameters are adjacent to the weld and Wire penetrameters are parallel to the weld.

Page 2 of 2

Page 70: NDT Code Book Made Easy

PENETRAMETER SELECTIONNote: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Wire: 0.025 Esn. Wire: B2 S/S Hole: 30

F/S Wire: 0.020 Esn. Wire: B3 F/S Hole: 25Welds with reinforcement: S/S Wire: 0.025 Esn. Wire: B2 S/S Hole: 30

F/S Wire: 0.020 Esn. Wire: B3 F/S Hole: 25Maximum allowable reinforcement: 0.0625"/per sideMaximum reinforcement with DWE/SWV: 0.125" Total of walls + reinforcement: 2.125" 53.9750 mmMaximum reinforcement with DWE/DWV: 0.125" Total of walls + reinforcement: 2.125" 53.9750 mmMaximum reinforcement with SWE/SWV: 0.0625" Total of wall + reinforcement: 1.0625" 26.9875 mm

INADEQUATE PENETRATION WITHOUT HIGH LOWMaximum length of individual indication of IP : 1 inch or 25mmMaximum length of IP in 8% of weld: N/A since total weld exceeds 12 inchesMaximum length of indications in any continuous 12" length of weld: 1" 25 mm

INADEQUATE PENETRATION DUE TO HIGH LOWMaximum length of individual indication of IPD: 2 inches or 50mmMaximum length of indications of IPD in any continuous 12" length of weld: 3" 75 mm

INADEQUATE CROSS PENETRATIONMaximum length of an individual indication of ICP: 2 inches or 50mmMaximum length of indications of ICP in any continuous 12" length of weld: 2" 50 mm

INCOMPLETE FUSIONMaximum length of an individual indication of IF: 1 inch or 25mmMaximum length of IF in 8% of weld: N/A since total weld exceeds 12 inchesMaximum length of indications of IF in any continuous 12" length of weld: 1" 25 mm

INCOMPLETE FUSION DUE TO COLD LAPMaximum length of individual indications of IFD: 2 inches or 50mmMaximum length of IFD in 8% of weld: 68.6994 mmMaximum length of indications of IFD in any continuous 12" length of weld: 2" 25 mm

INTERNAL CONCAVITY Any length of IC is acceptable, provided the density of the radiographic image of the internal concavity does not exceed that of the thinnest adjacent parent material. For areas that exceed the density of thethinnest adjacent parent material, the criteria for burn through are applicable.

BURN - THROUGHMaximum dimension of BT's image : unacceptable if it exceeds that of the thinnest adjacent parent metal.Maximum dimension of BT: 1/4" or 6mmMaximum dimension is unacceptable if: it exceeds the thinner of the nonnal wall thickness joined, and the density

of the BT's image exceeds that of the thinnest adjacent parent material.The sum of the max dimensions of separate BBT's whose image density exceeds that of the thinnest adjacent parentmaterial exceeds 1/2 inch or 13mm in any continuous 12" length of weld or the total weld length(whichever is less).

API - 110410" s/140 - 1.000" Wall

Page 1 of 2

Page 71: NDT Code Book Made Easy

API - 110410" s/140 - 1.000" Wall

SLAG INCLUSIONSElongated slag inclusions (ESI)Maximum length of an ESI: 2 inches or 50mmParallel ESI indications (Wagon Tracks) shall be considered a single indication unless the width of either of them exceed1/32" or 0.8mm. In that event they shall be considered separate indications.Maximum length of ESI indications in any continuous 12" length of weld: 2" 50 mmMaximum width of an individual ESI indication: 1/16" or 1.6mmIsolated slag inclusions (ISI)Maximum length of ISI indications in any continuous 12" length of weld: 1/2" 13 mmMaximum width of an ISI indication: 1/8" or 3mmMaximum length of ESI and ISI in 8% of weld: 68.6994 mm

POROSITY Individual or Scattered Porosity.Maximum size of an individual pore: 1/8" or 3mmThe size of an individual pore exceeds 25% of the thinner of the nonimal wall thickness joined.The distribution of scattered porosity exceeds the concentration permitted in Figures 19 or 20.Cluster Porosity (CP)Maximum diameter of the cluster: 1/2 inch or 13mmMaximum length of CP indications in any continuous 12" length of weweld: 1/2" 13 mmMaximum length of an individual pore within a cluster: 1/16 inch or 2mmHollow Bead Porosity (HB)Maximum length of an individual indication of HB: 1/2 inch or 13mmMaximum length of HB indications in any continuous 12" length of weld: 2" 50 mmMaximum length of HB in 8% of weld: 68.6994 mmNOTE: The weld is unacceptable if individual indications of HB, each greater than 1/4 inch or 6mm in length, are seperated by less than 2 inches or 50 mm.

CRACKSNote: Any crack which is not a shallow crater crack or star crack is unacceptable.Maximum length of shallow crater cracks or star cracks: 5/32 inch or 4mm

UNDERCUTTINGUndercutting adjacent to the cover pass (EU) and Undercutting adjacent to the root pass (IU)Maximum length of EU and IU indications (in any combination) in a 12 inch length of weld: 2" 50 mmMaximum length of EU and IU indications: 5.635" 143.1290 mm (This value is 1/6 th of the total weld length)

ACCUMULATION OF IMPERFECTIONSMaximum length of AI indications in any continuous 12 inch or 300 mm length of weld: 2" 50 mmMaximum length of AI indications of 8% of weld: 68.6994 mm

RADIOGRAPHIC INFOPipe O.D. in inches: 10.750"Amount of Penetrameters required for each shot: 1 penetrameter 1" from the end of film and 1 penny in the center.Total weld length: 33.80875" 858.7105 mmCassette size to complete weld in most efficient way: 3.5 x 17" 4.5 x 17"Amount of shots to complete weld with 1" on each side of readable film: 58% of weld: 2.7047" 68.6994 mmHole penetrameters are adjacent to the weld and Wire penetrameters are parallel to the weld.

Page 2 of 2

Page 72: NDT Code Book Made Easy

PENETRAMETER SELECTIONNote: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Wire: 0.025 Esn. Wire: B2 S/S Hole: 30

F/S Wire: 0.020 Esn. Wire: B3 F/S Hole: 25Welds with reinforcement: S/S Wire: 0.025 Esn. Wire: B2 S/S Hole: 30

F/S Wire: 0.020 Esn. Wire: B3 F/S Hole: 25Maximum allowable reinforcement: 0.0625"/per sideMaximum reinforcement with DWE/SWV: 0.125" Total of walls + reinforcement: 2.375" 60.3250 mmMaximum reinforcement with DWE/DWV: 0.125" Total of walls + reinforcement: 2.375" 60.3250 mmMaximum reinforcement with SWE/SWV: 0.0625" Total of wall + reinforcement: 1.1875" 30.1625 mm

INADEQUATE PENETRATION WITHOUT HIGH LOWMaximum length of individual indication of IP : 1 inch or 25mmMaximum length of IP in 8% of weld: N/A since total weld exceeds 12 inchesMaximum length of indications in any continuous 12" length of weld: 1" 25 mm

INADEQUATE PENETRATION DUE TO HIGH LOWMaximum length of individual indication of IPD: 2 inches or 50mmMaximum length of indications of IPD in any continuous 12" length of weld: 3" 75 mm

INADEQUATE CROSS PENETRATIONMaximum length of an individual indication of ICP: 2 inches or 50mmMaximum length of indications of ICP in any continuous 12" length of weld: 2" 50 mm

INCOMPLETE FUSIONMaximum length of an individual indication of IF: 1 inch or 25mmMaximum length of IF in 8% of weld: N/A since total weld exceeds 12 inchesMaximum length of indications of IF in any continuous 12" length of weld: 1" 25 mm

INCOMPLETE FUSION DUE TO COLD LAPMaximum length of individual indications of IFD: 2 inches or 50mmMaximum length of IFD in 8% of weld: 68.6994 mmMaximum length of indications of IFD in any continuous 12" length of weld: 2" 25 mm

INTERNAL CONCAVITY Any length of IC is acceptable, provided the density of the radiographic image of the internal concavity does not exceed that of the thinnest adjacent parent material. For areas that exceed the density of thethinnest adjacent parent material, the criteria for burn through are applicable.

BURN - THROUGHMaximum dimension of BT's image : unacceptable if it exceeds that of the thinnest adjacent parent metal.Maximum dimension of BT: 1/4" or 6mmMaximum dimension is unacceptable if: it exceeds the thinner of the nonnal wall thickness joined, and the density

of the BT's image exceeds that of the thinnest adjacent parent material.The sum of the max dimensions of separate BBT's whose image density exceeds that of the thinnest adjacent parentmaterial exceeds 1/2 inch or 13mm in any continuous 12" length of weld or the total weld length(whichever is less).

API - 110410" s/160 - 1.125" Wall

Page 1 of 2

Page 73: NDT Code Book Made Easy

API - 110410" s/160 - 1.125" Wall

SLAG INCLUSIONSElongated slag inclusions (ESI)Maximum length of an ESI: 2 inches or 50mmParallel ESI indications (Wagon Tracks) shall be considered a single indication unless the width of either of them exceed1/32" or 0.8mm. In that event they shall be considered separate indications.Maximum length of ESI indications in any continuous 12" length of weld: 2" 50 mmMaximum width of an individual ESI indication: 1/16" or 1.6mmIsolated slag inclusions (ISI)Maximum length of ISI indications in any continuous 12" length of weld: 1/2" 13 mmMaximum width of an ISI indication: 1/8" or 3mmMaximum length of ESI and ISI in 8% of weld: 68.6994 mm

POROSITY Individual or Scattered Porosity.Maximum size of an individual pore: 1/8" or 3mmThe size of an individual pore exceeds 25% of the thinner of the nonimal wall thickness joined.The distribution of scattered porosity exceeds the concentration permitted in Figures 19 or 20.Cluster Porosity (CP)Maximum diameter of the cluster: 1/2 inch or 13mmMaximum length of CP indications in any continuous 12" length of weweld: 1/2" 13 mmMaximum length of an individual pore within a cluster: 1/16 inch or 2mmHollow Bead Porosity (HB)Maximum length of an individual indication of HB: 1/2 inch or 13mmMaximum length of HB indications in any continuous 12" length of weld: 2" 50 mmMaximum length of HB in 8% of weld: 68.6994 mmNOTE: The weld is unacceptable if individual indications of HB, each greater than 1/4 inch or 6mm in length, are seperated by less than 2 inches or 50 mm.

CRACKSNote: Any crack which is not a shallow crater crack or star crack is unacceptable.Maximum length of shallow crater cracks or star cracks: 5/32 inch or 4mm

UNDERCUTTINGUndercutting adjacent to the cover pass (EU) and Undercutting adjacent to the root pass (IU)Maximum length of EU and IU indications (in any combination) in a 12 inch length of weld: 2" 50 mmMaximum length of EU and IU indications: 5.635" 143.1290 mm (This value is 1/6 th of the total weld length)

ACCUMULATION OF IMPERFECTIONSMaximum length of AI indications in any continuous 12 inch or 300 mm length of weld: 2" 50 mmMaximum length of AI indications of 8% of weld: 68.6994 mm

RADIOGRAPHIC INFOPipe O.D. in inches: 10.750"Amount of Penetrameters required for each shot: 1 penetrameter 1" from the end of film and 1 penny in the center.Total weld length: 33.80875" 858.7105 mmCassette size to complete weld in most efficient way: 3.5 x 17" 4.5 x 17"Amount of shots to complete weld with 1" on each side of readable film: 58% of weld: 2.7047" 68.6994 mmHole penetrameters are adjacent to the weld and Wire penetrameters are parallel to the weld.

Page 2 of 2

Page 74: NDT Code Book Made Easy

PENETRAMETER SELECTIONNote: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Wire: 0.020 Esn. Wire: B3 S/S Hole: 25

F/S Wire: 0.016 Esn. Wire: B4 F/S Hole: 20Welds with reinforcement: S/S Wire: 0.025 Esn. Wire: B2 S/S Hole: 30

F/S Wire: 0.020 Esn. Wire: B3 F/S Hole: 25Maximum allowable reinforcement: 0.0625"/per sideMaximum reinforcement with DWE/SWV: 0.125" Total of walls + reinforcement: 2.125" 53.9750 mmMaximum reinforcement with DWE/DWV: 0.125" Total of walls + reinforcement: 2.125" 53.9750 mmMaximum reinforcement with SWE/SWV: 0.0625" Total of wall + reinforcement: 1.0625" 26.9875 mm

INADEQUATE PENETRATION WITHOUT HIGH LOWMaximum length of individual indication of IP : 1 inch or 25mmMaximum length of IP in 8% of weld: N/A since total weld exceeds 12 inchesMaximum length of indications in any continuous 12" length of weld: 1" 25 mm

INADEQUATE PENETRATION DUE TO HIGH LOWMaximum length of individual indication of IPD: 2 inches or 50mmMaximum length of indications of IPD in any continuous 12" length of weld: 3" 75 mm

INADEQUATE CROSS PENETRATIONMaximum length of an individual indication of ICP: 2 inches or 50mmMaximum length of indications of ICP in any continuous 12" length of weld: 2" 50 mm

INCOMPLETE FUSIONMaximum length of an individual indication of IF: 1 inch or 25mmMaximum length of IF in 8% of weld: N/A since total weld exceeds 12 inchesMaximum length of indications of IF in any continuous 12" length of weld: 1" 25 mm

INCOMPLETE FUSION DUE TO COLD LAPMaximum length of individual indications of IFD: 2 inches or 50mmMaximum length of IFD in 8% of weld: 68.6994 mmMaximum length of indications of IFD in any continuous 12" length of weld: 2" 25 mm

INTERNAL CONCAVITY Any length of IC is acceptable, provided the density of the radiographic image of the internal concavity does not exceed that of the thinnest adjacent parent material. For areas that exceed the density of thethinnest adjacent parent material, the criteria for burn through are applicable.

BURN - THROUGHMaximum dimension of BT's image : unacceptable if it exceeds that of the thinnest adjacent parent metal.Maximum dimension of BT: 1/4" or 6mmMaximum dimension is unacceptable if: it exceeds the thinner of the nonnal wall thickness joined, and the density

of the BT's image exceeds that of the thinnest adjacent parent material.The sum of the max dimensions of separate BBT's whose image density exceeds that of the thinnest adjacent parentmaterial exceeds 1/2 inch or 13mm in any continuous 12" length of weld or the total weld length(whichever is less).

API - 110410" XX Strong - 1.00" Wall

Page 1 of 2

Page 75: NDT Code Book Made Easy

API - 110410" XX Strong - 1.00" Wall

SLAG INCLUSIONSElongated slag inclusions (ESI)Maximum length of an ESI: 2 inches or 50mmParallel ESI indications (Wagon Tracks) shall be considered a single indication unless the width of either of them exceed1/32" or 0.8mm. In that event they shall be considered separate indications.Maximum length of ESI indications in any continuous 12" length of weld: 2" 50 mmMaximum width of an individual ESI indication: 1/16" or 1.6mmIsolated slag inclusions (ISI)Maximum length of ISI indications in any continuous 12" length of weld: 1/2" 13 mmMaximum width of an ISI indication: 1/8" or 3mmMaximum length of ESI and ISI in 8% of weld: 68.6994 mm

POROSITY Individual or Scattered Porosity.Maximum size of an individual pore: 1/8" or 3mmThe size of an individual pore exceeds 25% of the thinner of the nonimal wall thickness joined.The distribution of scattered porosity exceeds the concentration permitted in Figures 19 or 20.Cluster Porosity (CP)Maximum diameter of the cluster: 1/2 inch or 13mmMaximum length of CP indications in any continuous 12" length of weweld: 1/2" 13 mmMaximum length of an individual pore within a cluster: 1/16 inch or 2mmHollow Bead Porosity (HB)Maximum length of an individual indication of HB: 1/2 inch or 13mmMaximum length of HB indications in any continuous 12" length of weld: 2" 50 mmMaximum length of HB in 8% of weld: 68.6994 mmNOTE: The weld is unacceptable if individual indications of HB, each greater than 1/4 inch or 6mm in length, are seperated by less than 2 inches or 50 mm.

CRACKSNote: Any crack which is not a shallow crater crack or star crack is unacceptable.Maximum length of shallow crater cracks or star cracks: 5/32 inch or 4mm

UNDERCUTTINGUndercutting adjacent to the cover pass (EU) and Undercutting adjacent to the root pass (IU)Maximum length of EU and IU indications (in any combination) in a 12 inch length of weld: 2" 50 mmMaximum length of EU and IU indications: 5.635" 143.1290 mm (This value is 1/6 th of the total weld length)

ACCUMULATION OF IMPERFECTIONSMaximum length of AI indications in any continuous 12 inch or 300 mm length of weld: 2" 50 mmMaximum length of AI indications of 8% of weld: 68.6994 mm

RADIOGRAPHIC INFOPipe O.D. in inches: 10.750"Amount of Penetrameters required for each shot: 1 penetrameter 1" from the end of film and 1 penny in the center.Total weld length: 33.80875" 858.7105 mmCassette size to complete weld in most efficient way: 3.5 x 17" 4.5 x 17"Amount of shots to complete weld with 1" on each side of readable film: 48% of weld: 2.7047" 68.6994 mmHole penetrameters are adjacent to the weld and Wire penetrameters are parallel to the weld.

Page 2 of 2

Page 76: NDT Code Book Made Easy

PENETRAMETER SELECTIONNote: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Wire: 0.008 Esn. Wire: A2 S/S Hole: 12

F/S Wire: 0.006 Esn. Wire: A3 F/S Hole: 10Welds with reinforcement: S/S Wire: 0.008 Esn. Wire: A2 S/S Hole: 12

F/S Wire: 0.006 Esn. Wire: A3 F/S Hole: 10Maximum allowable reinforcement: 0.0625"/per sideMaximum reinforcement with DWE/SWV: 0.125" Total of walls + reinforcement: .485" 12.3190 mmMaximum reinforcement with DWE/DWV: 0.125" Total of walls + reinforcement: .485" 12.3190 mmMaximum reinforcement with SWE/SWV: 0.0625" Total of wall + reinforcement: .2425" 6.1595

INADEQUATE PENETRATION WITHOUT HIGH LOWMaximum length of individual indication of IP : 1 inch or 25mmMaximum length of IP in 8% of weld: N/A since total weld exceeds 12 inchesMaximum length of indications in any continuous 12" length of weld: 1" 25 mm

INADEQUATE PENETRATION DUE TO HIGH LOWMaximum length of individual indication of IPD: 2 inches or 50mmMaximum length of indications of IPD in any continuous 12" length of weld: 3" 75 mm

INADEQUATE CROSS PENETRATIONMaximum length of an individual indication of ICP: 2 inches or 50mmMaximum length of indications of ICP in any continuous 12" length of weld: 2" 50 mm

INCOMPLETE FUSIONMaximum length of an individual indication of IF: 1 inch or 25mmMaximum length of IF in 8% of weld: N/A since total weld exceeds 12 inchesMaximum length of indications of IF in any continuous 12" length of weld: 1" 25 mm

INCOMPLETE FUSION DUE TO COLD LAPMaximum length of individual indications of IFD: 2 inches or 50mmMaximum length of IFD in 8% of weld: 81.4807 mmMaximum length of indications of IFD in any continuous 12" length of weld: 2" 25 mm

INTERNAL CONCAVITY Any length of IC is acceptable, provided the density of the radiographic image of the internal concavity does not exceed that of the thinnest adjacent parent material. For areas that exceed the density of thethinnest adjacent parent material, the criteria for burn through are applicable.

BURN - THROUGHMaximum dimension of BT's image : unacceptable if it exceeds that of the thinnest adjacent parent metal.Maximum dimension of BT: 1/4" or 6mmMaximum dimension is unacceptable if: it exceeds the thinner of the nonnal wall thickness joined, and the density

of the BT's image exceeds that of the thinnest adjacent parent material.The sum of the max dimensions of separate BBT's whose image density exceeds that of the thinnest adjacent parentmaterial exceeds 1/2 inch or 13mm in any continuous 12" length of weld or the total weld length(whichever is less).

API - 110412" s/10 - 0.180" Wall

Page 1 of 2

Page 77: NDT Code Book Made Easy

API - 110412" s/10 - 0.180" Wall

SLAG INCLUSIONSElongated slag inclusions (ESI)Maximum length of an ESI: 2 inches or 50mmParallel ESI indications (Wagon Tracks) shall be considered a single indication unless the width of either of them exceed1/32" or 0.8mm. In that event they shall be considered separate indications.Maximum length of ESI indications in any continuous 12" length of weld: 2" 50 mmMaximum width of an individual ESI indication: 1/16" or 1.6mmIsolated slag inclusions (ISI)Maximum length of ISI indications in any continuous 12" length of weld: 1/2" 13 mmMaximum width of an ISI indication: 1/8" or 3mmMaximum length of ESI and ISI in 8% of weld: 81.4807 mm

POROSITY Individual or Scattered Porosity.Maximum size of an individual pore: 1/8" or 3mmThe size of an individual pore exceeds 25% of the thinner of the nonimal wall thickness joined.The distribution of scattered porosity exceeds the concentration permitted in Figures 19 or 20.Cluster Porosity (CP)Maximum diameter of the cluster: 1/2 inch or 13mmMaximum length of CP indications in any continuous 12" length of weweld: 1/2" 13 mmMaximum length of an individual pore within a cluster: 1/16 inch or 2mmHollow Bead Porosity (HB)Maximum length of an individual indication of HB: 1/2 inch or 13mmMaximum length of HB indications in any continuous 12" length of weld: 2" 50 mmMaximum length of HB in 8% of weld: 81.4807 mmNOTE: The weld is unacceptable if individual indications of HB, each greater than 1/4 inch or 6mm in length, are seperated by less than 2 inches or 50 mm.

CRACKSNote: Any crack which is not a shallow crater crack or star crack is unacceptable.Maximum length of shallow crater cracks or star cracks: 5/32 inch or 4mm

UNDERCUTTINGUndercutting adjacent to the cover pass (EU) and Undercutting adjacent to the root pass (IU)Maximum length of EU and IU indications (in any combination) in a 12 inch length of weld: 2" 50 mmMaximum length of EU and IU indications: 6.683125" 169.7514 mm (This value is 1/6 th of the total weld length)

ACCUMULATION OF IMPERFECTIONSMaximum length of AI indications in any continuous 12 inch or 300 mm length of weld: 2" 50 mmMaximum length of AI indications of 8% of weld: 81.4807 mm

RADIOGRAPHIC INFOPipe O.D. in inches: 12.750 "Amount of Penetrameters required for each shot: 1 penetrameter 1" from the end of film and 1 penny in the center.Total weld length: 40.09875" 1018.5083 mmCassette size to complete weld in most efficient way: 3.5 x 17" 4.5 x 17"Amount of shots to complete weld with 1" on each side of readable film: 38% of weld: 3.2079" 81.4807 mmHole penetrameters are adjacent to the weld and Wire penetrameters are parallel to the weld.

Page 2 of 2

Page 78: NDT Code Book Made Easy

PENETRAMETER SELECTIONNote: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Wire: 0.010 Esn. Wire: A1 or B6 S/S Hole: 15

F/S Wire: 0.008 Esn. Wire: A2 F/S Hole: 12Welds with reinforcement: S/S Wire: 0.013 Esn. Wire: B5 S/S Hole: 17

F/S Wire: 0.010 Esn. Wire: A1 or B6 F/S Hole: 15Maximum allowable reinforcement: 0.0625"/per sideMaximum reinforcement with DWE/SWV: 0.125" Total of walls + reinforcement: .875" 22.2250 mmMaximum reinforcement with DWE/DWV: 0.125" Total of walls + reinforcement: .875" 22.2250 mmMaximum reinforcement with SWE/SWV: 0.0625" Total of wall + reinforcement: .4375" 11.1125 mm

INADEQUATE PENETRATION WITHOUT HIGH LOWMaximum length of individual indication of IP : 1 inch or 25mmMaximum length of IP in 8% of weld: N/A since total weld exceeds 12 inchesMaximum length of indications in any continuous 12" length of weld: 1" 25 mm

INADEQUATE PENETRATION DUE TO HIGH LOWMaximum length of individual indication of IPD: 2 inches or 50mmMaximum length of indications of IPD in any continuous 12" length of weld: 3" 75 mm

INADEQUATE CROSS PENETRATIONMaximum length of an individual indication of ICP: 2 inches or 50mmMaximum length of indications of ICP in any continuous 12" length of weld: 2" 50 mm

INCOMPLETE FUSIONMaximum length of an individual indication of IF: 1 inch or 25mmMaximum length of IF in 8% of weld: N/A since total weld exceeds 12 inchesMaximum length of indications of IF in any continuous 12" length of weld: 1" 25 mm

INCOMPLETE FUSION DUE TO COLD LAPMaximum length of individual indications of IFD: 2 inches or 50mmMaximum length of IFD in 8% of weld: 81.4807 mmMaximum length of indications of IFD in any continuous 12" length of weld: 2" 25 mm

INTERNAL CONCAVITY Any length of IC is acceptable, provided the density of the radiographic image of the internal concavity does not exceed that of the thinnest adjacent parent material. For areas that exceed the density of thethinnest adjacent parent material, the criteria for burn through are applicable.

BURN - THROUGHMaximum dimension of BT's image : unacceptable if it exceeds that of the thinnest adjacent parent metal.Maximum dimension of BT: 1/4" or 6mmMaximum dimension is unacceptable if: it exceeds the thinner of the nonnal wall thickness joined, and the density

of the BT's image exceeds that of the thinnest adjacent parent material.The sum of the max dimensions of separate BBT's whose image density exceeds that of the thinnest adjacent parentmaterial exceeds 1/2 inch or 13mm in any continuous 12" length of weld or the total weld length(whichever is less).

API - 110412" Standard - 0.375" Wall

Page 1 of 2

Page 79: NDT Code Book Made Easy

API - 110412" Standard - 0.375" Wall

SLAG INCLUSIONSElongated slag inclusions (ESI)Maximum length of an ESI: 2 inches or 50mmParallel ESI indications (Wagon Tracks) shall be considered a single indication unless the width of either of them exceed1/32" or 0.8mm. In that event they shall be considered separate indications.Maximum length of ESI indications in any continuous 12" length of weld: 2" 50 mmMaximum width of an individual ESI indication: 1/16" or 1.6mmIsolated slag inclusions (ISI)Maximum length of ISI indications in any continuous 12" length of weld: 1/2" 13 mmMaximum width of an ISI indication: 1/8" or 3mmMaximum length of ESI and ISI in 8% of weld: 81.4807 mm

POROSITY Individual or Scattered Porosity.Maximum size of an individual pore: 1/8" or 3mmThe size of an individual pore exceeds 25% of the thinner of the nonimal wall thickness joined.The distribution of scattered porosity exceeds the concentration permitted in Figures 19 or 20.Cluster Porosity (CP)Maximum diameter of the cluster: 1/2 inch or 13mmMaximum length of CP indications in any continuous 12" length of weweld: 1/2" 13 mmMaximum length of an individual pore within a cluster: 1/16 inch or 2mmHollow Bead Porosity (HB)Maximum length of an individual indication of HB: 1/2 inch or 13mmMaximum length of HB indications in any continuous 12" length of weld: 2" 50 mmMaximum length of HB in 8% of weld: 81.4807 mmNOTE: The weld is unacceptable if individual indications of HB, each greater than 1/4 inch or 6mm in length, are seperated by less than 2 inches or 50 mm.

CRACKSNote: Any crack which is not a shallow crater crack or star crack is unacceptable.Maximum length of shallow crater cracks or star cracks: 5/32 inch or 4mm

UNDERCUTTINGUndercutting adjacent to the cover pass (EU) and Undercutting adjacent to the root pass (IU)Maximum length of EU and IU indications (in any combination) in a 12 inch length of weld: 2" 50 mmMaximum length of EU and IU indications: 6.683125" 169.7514 mm (This value is 1/6 th of the total weld length)

ACCUMULATION OF IMPERFECTIONSMaximum length of AI indications in any continuous 12 inch or 300 mm length of weld: 2" 50 mmMaximum length of AI indications of 8% of weld: 81.4807 mm

RADIOGRAPHIC INFOPipe O.D. in inches: 12.750 "Amount of Penetrameters required for each shot: 1 penetrameter 1" from the end of film and 1 penny in the center.Total weld length: 40.09875" 1018.5083 mmCassette size to complete weld in most efficient way: 3.5 x 17" 4.5 x 17"Amount of shots to complete weld with 1" on each side of readable film: 38% of weld: 3.2079" 81.4807 mmHole penetrameters are adjacent to the weld and Wire penetrameters are parallel to the weld.

Page 2 of 2

Page 80: NDT Code Book Made Easy

PENETRAMETER SELECTIONNote: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Wire: 0.013 Esn. Wire: B5 S/S Hole: 17

F/S Wire: 0.010 Esn. Wire: A1 or B6 F/S Hole: 15Welds with reinforcement: S/S Wire: 0.016 Esn. Wire: B4 S/S Hole: 20

F/S Wire: 0.013 Esn. Wire: B5 F/S Hole: 17Maximum allowable reinforcement: 0.0625"/per sideMaximum reinforcement with DWE/SWV: 0.125" Total of walls + reinforcement: .937" 23.7998 mmMaximum reinforcement with DWE/DWV: 0.125" Total of walls + reinforcement: .937" 23.7998 mmMaximum reinforcement with SWE/SWV: 0.0625" Total of wall + reinforcement: .4685" 11.8999 mm

INADEQUATE PENETRATION WITHOUT HIGH LOWMaximum length of individual indication of IP : 1 inch or 25mmMaximum length of IP in 8% of weld: N/A since total weld exceeds 12 inchesMaximum length of indications in any continuous 12" length of weld: 1" 25 mm

INADEQUATE PENETRATION DUE TO HIGH LOWMaximum length of individual indication of IPD: 2 inches or 50mmMaximum length of indications of IPD in any continuous 12" length of weld: 3" 75 mm

INADEQUATE CROSS PENETRATIONMaximum length of an individual indication of ICP: 2 inches or 50mmMaximum length of indications of ICP in any continuous 12" length of weld: 2" 50 mm

INCOMPLETE FUSIONMaximum length of an individual indication of IF: 1 inch or 25mmMaximum length of IF in 8% of weld: N/A since total weld exceeds 12 inchesMaximum length of indications of IF in any continuous 12" length of weld: 1" 25 mm

INCOMPLETE FUSION DUE TO COLD LAPMaximum length of individual indications of IFD: 2 inches or 50mmMaximum length of IFD in 8% of weld: 81.4807 mmMaximum length of indications of IFD in any continuous 12" length of weld: 2" 25 mm

INTERNAL CONCAVITY Any length of IC is acceptable, provided the density of the radiographic image of the internal concavity does not exceed that of the thinnest adjacent parent material. For areas that exceed the density of thethinnest adjacent parent material, the criteria for burn through are applicable.

BURN - THROUGHMaximum dimension of BT's image : unacceptable if it exceeds that of the thinnest adjacent parent metal.Maximum dimension of BT: 1/4" or 6mmMaximum dimension is unacceptable if: it exceeds the thinner of the nonnal wall thickness joined, and the density

of the BT's image exceeds that of the thinnest adjacent parent material.The sum of the max dimensions of separate BBT's whose image density exceeds that of the thinnest adjacent parentmaterial exceeds 1/2 inch or 13mm in any continuous 12" length of weld or the total weld length(whichever is less).

API - 110412" s/40 - 0.406" Wall

Page 1 of 2

Page 81: NDT Code Book Made Easy

API - 110412" s/40 - 0.406" Wall

SLAG INCLUSIONSElongated slag inclusions (ESI)Maximum length of an ESI: 2 inches or 50mmParallel ESI indications (Wagon Tracks) shall be considered a single indication unless the width of either of them exceed1/32" or 0.8mm. In that event they shall be considered separate indications.Maximum length of ESI indications in any continuous 12" length of weld: 2" 50 mmMaximum width of an individual ESI indication: 1/16" or 1.6mmIsolated slag inclusions (ISI)Maximum length of ISI indications in any continuous 12" length of weld: 1/2" 13 mmMaximum width of an ISI indication: 1/8" or 3mmMaximum length of ESI and ISI in 8% of weld: 81.4807 mm

POROSITY Individual or Scattered Porosity.Maximum size of an individual pore: 1/8" or 3mmThe size of an individual pore exceeds 25% of the thinner of the nonimal wall thickness joined.The distribution of scattered porosity exceeds the concentration permitted in Figures 19 or 20.Cluster Porosity (CP)Maximum diameter of the cluster: 1/2 inch or 13mmMaximum length of CP indications in any continuous 12" length of weweld: 1/2" 13 mmMaximum length of an individual pore within a cluster: 1/16 inch or 2mmHollow Bead Porosity (HB)Maximum length of an individual indication of HB: 1/2 inch or 13mmMaximum length of HB indications in any continuous 12" length of weld: 2" 50 mmMaximum length of HB in 8% of weld: 81.4807 mmNOTE: The weld is unacceptable if individual indications of HB, each greater than 1/4 inch or 6mm in length, are seperated by less than 2 inches or 50 mm.

CRACKSNote: Any crack which is not a shallow crater crack or star crack is unacceptable.Maximum length of shallow crater cracks or star cracks: 5/32 inch or 4mm

UNDERCUTTINGUndercutting adjacent to the cover pass (EU) and Undercutting adjacent to the root pass (IU)Maximum length of EU and IU indications (in any combination) in a 12 inch length of weld: 2" 50 mmMaximum length of EU and IU indications: 6.683125" 169.7514 mm (This value is 1/6 th of the total weld length)

ACCUMULATION OF IMPERFECTIONSMaximum length of AI indications in any continuous 12 inch or 300 mm length of weld: 2" 50 mmMaximum length of AI indications of 8% of weld: 81.4807 mm

RADIOGRAPHIC INFOPipe O.D. in inches: 12.750 "Amount of Penetrameters required for each shot: 1 penetrameter 1" from the end of film and 1 penny in the center.Total weld length: 40.09875" 1018.5083 mmCassette size to complete weld in most efficient way: 3.5 x 17" 4.5 x 17"Amount of shots to complete weld with 1" on each side of readable film: 38% of weld: 3.2079" 81.4807 mmHole penetrameters are adjacent to the weld and Wire penetrameters are parallel to the weld.

Page 2 of 2

Page 82: NDT Code Book Made Easy

PENETRAMETER SELECTIONNote: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Wire: 0.016 Esn. Wire: B4 S/S Hole: 20

F/S Wire: 0.013 Esn. Wire: B5 F/S Hole: 17Welds with reinforcement: S/S Wire: 0.020 Esn. Wire: B3 S/S Hole: 25

F/S Wire: 0.016 Esn. Wire: B4 F/S Hole: 20Maximum allowable reinforcement: 0.0625"/per sideMaximum reinforcement with DWE/SWV: 0.125" Total of walls + reinforcement: 1.501" 38.1254 mmMaximum reinforcement with DWE/DWV: 0.125" Total of walls + reinforcement: 1.501" 38.1254 mmMaximum reinforcement with SWE/SWV: 0.0625" Total of wall + reinforcement: .7505" 19.0627 mm

INADEQUATE PENETRATION WITHOUT HIGH LOWMaximum length of individual indication of IP : 1 inch or 25mmMaximum length of IP in 8% of weld: N/A since total weld exceeds 12 inchesMaximum length of indications in any continuous 12" length of weld: 1" 25 mm

INADEQUATE PENETRATION DUE TO HIGH LOWMaximum length of individual indication of IPD: 2 inches or 50mmMaximum length of indications of IPD in any continuous 12" length of weld: 3" 75 mm

INADEQUATE CROSS PENETRATIONMaximum length of an individual indication of ICP: 2 inches or 50mmMaximum length of indications of ICP in any continuous 12" length of weld: 2" 50 mm

INCOMPLETE FUSIONMaximum length of an individual indication of IF: 1 inch or 25mmMaximum length of IF in 8% of weld: N/A since total weld exceeds 12 inchesMaximum length of indications of IF in any continuous 12" length of weld: 1" 25 mm

INCOMPLETE FUSION DUE TO COLD LAPMaximum length of individual indications of IFD: 2 inches or 50mmMaximum length of IFD in 8% of weld: 81.4807 mmMaximum length of indications of IFD in any continuous 12" length of weld: 2" 25 mm

INTERNAL CONCAVITY Any length of IC is acceptable, provided the density of the radiographic image of the internal concavity does not exceed that of the thinnest adjacent parent material. For areas that exceed the density of thethinnest adjacent parent material, the criteria for burn through are applicable.

BURN - THROUGHMaximum dimension of BT's image : unacceptable if it exceeds that of the thinnest adjacent parent metal.Maximum dimension of BT: 1/4" or 6mmMaximum dimension is unacceptable if: it exceeds the thinner of the nonnal wall thickness joined, and the density

of the BT's image exceeds that of the thinnest adjacent parent material.The sum of the max dimensions of separate BBT's whose image density exceeds that of the thinnest adjacent parentmaterial exceeds 1/2 inch or 13mm in any continuous 12" length of weld or the total weld length(whichever is less).

API - 110412" s/80 - 0.688" Wall

Page 1 of 2

Page 83: NDT Code Book Made Easy

API - 110412" s/80 - 0.688" Wall

SLAG INCLUSIONSElongated slag inclusions (ESI)Maximum length of an ESI: 2 inches or 50mmParallel ESI indications (Wagon Tracks) shall be considered a single indication unless the width of either of them exceed1/32" or 0.8mm. In that event they shall be considered separate indications.Maximum length of ESI indications in any continuous 12" length of weld: 2" 50 mmMaximum width of an individual ESI indication: 1/16" or 1.6mmIsolated slag inclusions (ISI)Maximum length of ISI indications in any continuous 12" length of weld: 1/2" 13 mmMaximum width of an ISI indication: 1/8" or 3mmMaximum length of ESI and ISI in 8% of weld: 81.4807 mm

POROSITY Individual or Scattered Porosity.Maximum size of an individual pore: 1/8" or 3mmThe size of an individual pore exceeds 25% of the thinner of the nonimal wall thickness joined.The distribution of scattered porosity exceeds the concentration permitted in Figures 19 or 20.Cluster Porosity (CP)Maximum diameter of the cluster: 1/2 inch or 13mmMaximum length of CP indications in any continuous 12" length of weweld: 1/2" 13 mmMaximum length of an individual pore within a cluster: 1/16 inch or 2mmHollow Bead Porosity (HB)Maximum length of an individual indication of HB: 1/2 inch or 13mmMaximum length of HB indications in any continuous 12" length of weld: 2" 50 mmMaximum length of HB in 8% of weld: 81.4807 mmNOTE: The weld is unacceptable if individual indications of HB, each greater than 1/4 inch or 6mm in length, are seperated by less than 2 inches or 50 mm.

CRACKSNote: Any crack which is not a shallow crater crack or star crack is unacceptable.Maximum length of shallow crater cracks or star cracks: 5/32 inch or 4mm

UNDERCUTTINGUndercutting adjacent to the cover pass (EU) and Undercutting adjacent to the root pass (IU)Maximum length of EU and IU indications (in any combination) in a 12 inch length of weld: 2" 50 mmMaximum length of EU and IU indications: 6.683125" 169.7514 mm (This value is 1/6 th of the total weld length)

ACCUMULATION OF IMPERFECTIONSMaximum length of AI indications in any continuous 12 inch or 300 mm length of weld: 2" 50 mmMaximum length of AI indications of 8% of weld: 81.4807 mm

RADIOGRAPHIC INFOPipe O.D. in inches: 12.750 "Amount of Penetrameters required for each shot: 1 penetrameter 1" from the end of film and 1 penny in the center.Total weld length: 40.09875" 1018.5083 mmCassette size to complete weld in most efficient way: 3.5 x 17" 4.5 x 17"Amount of shots to complete weld with 1" on each side of readable film: 38% of weld: 3.2079" 81.4807 mmHole penetrameters are adjacent to the weld and Wire penetrameters are parallel to the weld.

Page 2 of 2

Page 84: NDT Code Book Made Easy

PENETRAMETER SELECTIONNote: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Wire: 0.025 Esn. Wire: B2 S/S Hole: 30

F/S Wire: 0.020 Esn. Wire: B3 F/S Hole: 25Welds with reinforcement: S/S Wire: 0.025 Esn. Wire: B2 S/S Hole: 30

F/S Wire: 0.020 Esn. Wire: B3 F/S Hole: 25Maximum allowable reinforcement: 0.0625"/per sideMaximum reinforcement with DWE/SWV: 0.125" Total of walls + reinforcement: 2.375" 60.3250 mmMaximum reinforcement with DWE/DWV: 0.125" Total of walls + reinforcement: 2.375" 60.3250 mmMaximum reinforcement with SWE/SWV: 0.0625" Total of wall + reinforcement: 1.1875" 30.1625 mm

INADEQUATE PENETRATION WITHOUT HIGH LOWMaximum length of individual indication of IP : 1 inch or 25mmMaximum length of IP in 8% of weld: N/A since total weld exceeds 12 inchesMaximum length of indications in any continuous 12" length of weld: 1" 25 mm

INADEQUATE PENETRATION DUE TO HIGH LOWMaximum length of individual indication of IPD: 2 inches or 50mmMaximum length of indications of IPD in any continuous 12" length of weld: 3" 75 mm

INADEQUATE CROSS PENETRATIONMaximum length of an individual indication of ICP: 2 inches or 50mmMaximum length of indications of ICP in any continuous 12" length of weld: 2" 50 mm

INCOMPLETE FUSIONMaximum length of an individual indication of IF: 1 inch or 25mmMaximum length of IF in 8% of weld: N/A since total weld exceeds 12 inchesMaximum length of indications of IF in any continuous 12" length of weld: 1" 25 mm

INCOMPLETE FUSION DUE TO COLD LAPMaximum length of individual indications of IFD: 2 inches or 50mmMaximum length of IFD in 8% of weld: 81.4807 mmMaximum length of indications of IFD in any continuous 12" length of weld: 2" 25 mm

INTERNAL CONCAVITY Any length of IC is acceptable, provided the density of the radiographic image of the internal concavity does not exceed that of the thinnest adjacent parent material. For areas that exceed the density of thethinnest adjacent parent material, the criteria for burn through are applicable.

BURN - THROUGHMaximum dimension of BT's image : unacceptable if it exceeds that of the thinnest adjacent parent metal.Maximum dimension of BT: 1/4" or 6mmMaximum dimension is unacceptable if: it exceeds the thinner of the nonnal wall thickness joined, and the density

of the BT's image exceeds that of the thinnest adjacent parent material.The sum of the max dimensions of separate BBT's whose image density exceeds that of the thinnest adjacent parentmaterial exceeds 1/2 inch or 13mm in any continuous 12" length of weld or the total weld length(whichever is less).

API - 110412" s/140 - 1.125" Wall

Page 1 of 2

Page 85: NDT Code Book Made Easy

API - 110412" s/140 - 1.125" Wall

SLAG INCLUSIONSElongated slag inclusions (ESI)Maximum length of an ESI: 2 inches or 50mmParallel ESI indications (Wagon Tracks) shall be considered a single indication unless the width of either of them exceed1/32" or 0.8mm. In that event they shall be considered separate indications.Maximum length of ESI indications in any continuous 12" length of weld: 2" 50 mmMaximum width of an individual ESI indication: 1/16" or 1.6mmIsolated slag inclusions (ISI)Maximum length of ISI indications in any continuous 12" length of weld: 1/2" 13 mmMaximum width of an ISI indication: 1/8" or 3mmMaximum length of ESI and ISI in 8% of weld: 81.4807 mm

POROSITY Individual or Scattered Porosity.Maximum size of an individual pore: 1/8" or 3mmThe size of an individual pore exceeds 25% of the thinner of the nonimal wall thickness joined.The distribution of scattered porosity exceeds the concentration permitted in Figures 19 or 20.Cluster Porosity (CP)Maximum diameter of the cluster: 1/2 inch or 13mmMaximum length of CP indications in any continuous 12" length of weweld: 1/2" 13 mmMaximum length of an individual pore within a cluster: 1/16 inch or 2mmHollow Bead Porosity (HB)Maximum length of an individual indication of HB: 1/2 inch or 13mmMaximum length of HB indications in any continuous 12" length of weld: 2" 50 mmMaximum length of HB in 8% of weld: 81.4807 mmNOTE: The weld is unacceptable if individual indications of HB, each greater than 1/4 inch or 6mm in length, are seperated by less than 2 inches or 50 mm.

CRACKSNote: Any crack which is not a shallow crater crack or star crack is unacceptable.Maximum length of shallow crater cracks or star cracks: 5/32 inch or 4mm

UNDERCUTTINGUndercutting adjacent to the cover pass (EU) and Undercutting adjacent to the root pass (IU)Maximum length of EU and IU indications (in any combination) in a 12 inch length of weld: 2" 50 mmMaximum length of EU and IU indications: 6.683125" 169.7514 mm (This value is 1/6 th of the total weld length)

ACCUMULATION OF IMPERFECTIONSMaximum length of AI indications in any continuous 12 inch or 300 mm length of weld: 2" 50 mmMaximum length of AI indications of 8% of weld: 81.4807 mm

RADIOGRAPHIC INFOPipe O.D. in inches: 12.750 "Amount of Penetrameters required for each shot: 1 penetrameter 1" from the end of film and 1 penny in the center.Total weld length: 40.09875" 1018.5083 mmCassette size to complete weld in most efficient way: 3.5 x 17" 4.5 x 17"Amount of shots to complete weld with 1" on each side of readable film: 38% of weld: 3.2079" 81.4807 mmHole penetrameters are adjacent to the weld and Wire penetrameters are parallel to the weld.

Page 2 of 2

Page 86: NDT Code Book Made Easy

PENETRAMETER SELECTIONNote: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Wire: 0.013 Esn. Wire: B5 S/S Hole: 17

F/S Wire: 0.010 Esn. Wire: A1 or B6 F/S Hole: 15Welds with reinforcement: S/S Wire: 0.016 Esn. Wire: B4 S/S Hole: 20

F/S Wire: 0.013 Esn. Wire: B5 F/S Hole: 17Maximum allowable reinforcement: 0.0625"/per sideMaximum reinforcement with DWE/SWV: 0.125" Total of walls + reinforcement: 1.125" 28.5750 mmMaximum reinforcement with DWE/DWV: 0.125" Total of walls + reinforcement: 1.125" 28.5750 mmMaximum reinforcement with SWE/SWV: 0.0625" Total of wall + reinforcement: .5625" 14.2875 mm

INADEQUATE PENETRATION WITHOUT HIGH LOWMaximum length of individual indication of IP : 1 inch or 25mmMaximum length of IP in 8% of weld: N/A since total weld exceeds 12 inchesMaximum length of indications in any continuous 12" length of weld: 1" 25 mm

INADEQUATE PENETRATION DUE TO HIGH LOWMaximum length of individual indication of IPD: 2 inches or 50mmMaximum length of indications of IPD in any continuous 12" length of weld: 3" 75 mm

INADEQUATE CROSS PENETRATIONMaximum length of an individual indication of ICP: 2 inches or 50mmMaximum length of indications of ICP in any continuous 12" length of weld: 2" 50 mm

INCOMPLETE FUSIONMaximum length of an individual indication of IF: 1 inch or 25mmMaximum length of IF in 8% of weld: N/A since total weld exceeds 12 inchesMaximum length of indications of IF in any continuous 12" length of weld: 1" 25 mm

INCOMPLETE FUSION DUE TO COLD LAPMaximum length of individual indications of IFD: 2 inches or 50mmMaximum length of IFD in 8% of weld: 81.4807 mmMaximum length of indications of IFD in any continuous 12" length of weld: 2" 25 mm

INTERNAL CONCAVITY Any length of IC is acceptable, provided the density of the radiographic image of the internal concavity does not exceed that of the thinnest adjacent parent material. For areas that exceed the density of thethinnest adjacent parent material, the criteria for burn through are applicable.

BURN - THROUGHMaximum dimension of BT's image : unacceptable if it exceeds that of the thinnest adjacent parent metal.Maximum dimension of BT: 1/4" or 6mmMaximum dimension is unacceptable if: it exceeds the thinner of the nonnal wall thickness joined, and the density

of the BT's image exceeds that of the thinnest adjacent parent material.The sum of the max dimensions of separate BBT's whose image density exceeds that of the thinnest adjacent parentmaterial exceeds 1/2 inch or 13mm in any continuous 12" length of weld or the total weld length(whichever is less).

API - 110412" Extra Strong - 0.500" Wall

Page 1 of 2

Page 87: NDT Code Book Made Easy

API - 110412" Extra Strong - 0.500" Wall

SLAG INCLUSIONSElongated slag inclusions (ESI)Maximum length of an ESI: 2 inches or 50mmParallel ESI indications (Wagon Tracks) shall be considered a single indication unless the width of either of them exceed1/32" or 0.8mm. In that event they shall be considered separate indications.Maximum length of ESI indications in any continuous 12" length of weld: 2" 50 mmMaximum width of an individual ESI indication: 1/16" or 1.6mmIsolated slag inclusions (ISI)Maximum length of ISI indications in any continuous 12" length of weld: 1/2" 13 mmMaximum width of an ISI indication: 1/8" or 3mmMaximum length of ESI and ISI in 8% of weld: 81.4807 mm

POROSITY Individual or Scattered Porosity.Maximum size of an individual pore: 1/8" or 3mmThe size of an individual pore exceeds 25% of the thinner of the nonimal wall thickness joined.The distribution of scattered porosity exceeds the concentration permitted in Figures 19 or 20.Cluster Porosity (CP)Maximum diameter of the cluster: 1/2 inch or 13mmMaximum length of CP indications in any continuous 12" length of weweld: 1/2" 13 mmMaximum length of an individual pore within a cluster: 1/16 inch or 2mmHollow Bead Porosity (HB)Maximum length of an individual indication of HB: 1/2 inch or 13mmMaximum length of HB indications in any continuous 12" length of weld: 2" 50 mmMaximum length of HB in 8% of weld: 81.4807 mmNOTE: The weld is unacceptable if individual indications of HB, each greater than 1/4 inch or 6mm in length, are seperated by less than 2 inches or 50 mm.

CRACKSNote: Any crack which is not a shallow crater crack or star crack is unacceptable.Maximum length of shallow crater cracks or star cracks: 5/32 inch or 4mm

UNDERCUTTINGUndercutting adjacent to the cover pass (EU) and Undercutting adjacent to the root pass (IU)Maximum length of EU and IU indications (in any combination) in a 12 inch length of weld: 2" 50 mmMaximum length of EU and IU indications: 6.683125" 169.7514 mm (This value is 1/6 th of the total weld length)

ACCUMULATION OF IMPERFECTIONSMaximum length of AI indications in any continuous 12 inch or 300 mm length of weld: 2" 50 mmMaximum length of AI indications of 8% of weld: 81.4807 mm

RADIOGRAPHIC INFOPipe O.D. in inches: 12.750 "Amount of Penetrameters required for each shot: 1 penetrameter 1" from the end of film and 1 penny in the center.Total weld length: 40.09875" 1018.5083 mmCassette size to complete weld in most efficient way: 3.5 x 17" 4.5 x 17"Amount of shots to complete weld with 1" on each side of readable film: 38% of weld: 3.2079" 81.4807 mmHole penetrameters are adjacent to the weld and Wire penetrameters are parallel to the weld.

Page 2 of 2

Page 88: NDT Code Book Made Easy

PENETRAMETER SELECTIONNote: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Wire: 0.020 Esn. Wire: B3 S/S Hole: 25

F/S Wire: 0.016 Esn. Wire: B4 F/S Hole: 20Welds with reinforcement: S/S Wire: 0.025 Esn. Wire: B2 S/S Hole: 30

F/S Wire: 0.020 Esn. Wire: B3 F/S Hole: 25Maximum allowable reinforcement: 0.0625"/per sideMaximum reinforcement with DWE/SWV: 0.125" Total of walls + reinforcement: 2.125" 53.9750 mmMaximum reinforcement with DWE/DWV: 0.125" Total of walls + reinforcement: 2.125" 53.9750 mmMaximum reinforcement with SWE/SWV: 0.0625" Total of wall + reinforcement: 1.0625" 26.9875 mm

INADEQUATE PENETRATION WITHOUT HIGH LOWMaximum length of individual indication of IP : 1 inch or 25mmMaximum length of IP in 8% of weld: N/A since total weld exceeds 12 inchesMaximum length of indications in any continuous 12" length of weld: 1" 25 mm

INADEQUATE PENETRATION DUE TO HIGH LOWMaximum length of individual indication of IPD: 2 inches or 50mmMaximum length of indications of IPD in any continuous 12" length of weld: 3" 75 mm

INADEQUATE CROSS PENETRATIONMaximum length of an individual indication of ICP: 2 inches or 50mmMaximum length of indications of ICP in any continuous 12" length of weld: 2" 50 mm

INCOMPLETE FUSIONMaximum length of an individual indication of IF: 1 inch or 25mmMaximum length of IF in 8% of weld: N/A since total weld exceeds 12 inchesMaximum length of indications of IF in any continuous 12" length of weld: 1" 25 mm

INCOMPLETE FUSION DUE TO COLD LAPMaximum length of individual indications of IFD: 2 inches or 50mmMaximum length of IFD in 8% of weld: 81.4807 mmMaximum length of indications of IFD in any continuous 12" length of weld: 2" 25 mm

INTERNAL CONCAVITY Any length of IC is acceptable, provided the density of the radiographic image of the internal concavity does not exceed that of the thinnest adjacent parent material. For areas that exceed the density of thethinnest adjacent parent material, the criteria for burn through are applicable.

BURN - THROUGHMaximum dimension of BT's image : unacceptable if it exceeds that of the thinnest adjacent parent metal.Maximum dimension of BT: 1/4" or 6mmMaximum dimension is unacceptable if: it exceeds the thinner of the nonnal wall thickness joined, and the density

of the BT's image exceeds that of the thinnest adjacent parent material.The sum of the max dimensions of separate BBT's whose image density exceeds that of the thinnest adjacent parentmaterial exceeds 1/2 inch or 13mm in any continuous 12" length of weld or the total weld length(whichever is less).

API - 110412" XX Strong - 1.00" Wall

Page 1 of 2

Page 89: NDT Code Book Made Easy

API - 110412" XX Strong - 1.00" Wall

SLAG INCLUSIONSElongated slag inclusions (ESI)Maximum length of an ESI: 2 inches or 50mmParallel ESI indications (Wagon Tracks) shall be considered a single indication unless the width of either of them exceed1/32" or 0.8mm. In that event they shall be considered separate indications.Maximum length of ESI indications in any continuous 12" length of weld: 2" 50 mmMaximum width of an individual ESI indication: 1/16" or 1.6mmIsolated slag inclusions (ISI)Maximum length of ISI indications in any continuous 12" length of weld: 1/2" 13 mmMaximum width of an ISI indication: 1/8" or 3mmMaximum length of ESI and ISI in 8% of weld: 81.4807 mm

POROSITY Individual or Scattered Porosity.Maximum size of an individual pore: 1/8" or 3mmThe size of an individual pore exceeds 25% of the thinner of the nonimal wall thickness joined.The distribution of scattered porosity exceeds the concentration permitted in Figures 19 or 20.Cluster Porosity (CP)Maximum diameter of the cluster: 1/2 inch or 13mmMaximum length of CP indications in any continuous 12" length of weweld: 1/2" 13 mmMaximum length of an individual pore within a cluster: 1/16 inch or 2mmHollow Bead Porosity (HB)Maximum length of an individual indication of HB: 1/2 inch or 13mmMaximum length of HB indications in any continuous 12" length of weld: 2" 50 mmMaximum length of HB in 8% of weld: 81.4807 mmNOTE: The weld is unacceptable if individual indications of HB, each greater than 1/4 inch or 6mm in length, are seperated by less than 2 inches or 50 mm.

CRACKSNote: Any crack which is not a shallow crater crack or star crack is unacceptable.Maximum length of shallow crater cracks or star cracks: 5/32 inch or 4mm

UNDERCUTTINGUndercutting adjacent to the cover pass (EU) and Undercutting adjacent to the root pass (IU)Maximum length of EU and IU indications (in any combination) in a 12 inch length of weld: 2" 50 mmMaximum length of EU and IU indications: 6.683125" 169.7514 mm (This value is 1/6 th of the total weld length)

ACCUMULATION OF IMPERFECTIONSMaximum length of AI indications in any continuous 12 inch or 300 mm length of weld: 2" 50 mmMaximum length of AI indications of 8% of weld: 81.4807 mm

RADIOGRAPHIC INFOPipe O.D. in inches: 12.750 "Amount of Penetrameters required for each shot: 1 penetrameter 1" from the end of film and 1 penny in the center.Total weld length: 40.09875" 1018.5083 mmCassette size to complete weld in most efficient way: 3.5 x 17" 4.5 x 17"Amount of shots to complete weld with 1" on each side of readable film: 48% of weld: 3.2079" 81.4807 mmHole penetrameters are adjacent to the weld and Wire penetrameters are parallel to the weld.

Page 2 of 2

Page 90: NDT Code Book Made Easy

PENETRAMETER SELECTIONNote: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Wire: 0.020 Esn. Wire: B3 S/S Hole: 25

F/S Wire: 0.016 Esn. Wire: B4 F/S Hole: 20Welds with reinforcement: S/S Wire: 0.025 Esn. Wire: B2 S/S Hole: 30

F/S Wire: 0.020 Esn. Wire: B3 F/S Hole: 25Maximum allowable reinforcement: 0.0625"/per sideMaximum reinforcement with DWE/SWV: 0.125" Total of walls + reinforcement: 2.125" 53.9750 mmMaximum reinforcement with DWE/DWV: 0.125" Total of walls + reinforcement: 2.125" 53.9750 mmMaximum reinforcement with SWE/SWV: 0.0625" Total of wall + reinforcement: 1.0625" 26.9875 mm

INADEQUATE PENETRATION WITHOUT HIGH LOWMaximum length of individual indication of IP : 1 inch or 25mmMaximum length of IP in 8% of weld: N/A since total weld exceeds 12 inchesMaximum length of indications in any continuous 12" length of weld: 1" 25 mm

INADEQUATE PENETRATION DUE TO HIGH LOWMaximum length of individual indication of IPD: 2 inches or 50mmMaximum length of indications of IPD in any continuous 12" length of weld: 3" 75 mm

INADEQUATE CROSS PENETRATIONMaximum length of an individual indication of ICP: 2 inches or 50mmMaximum length of indications of ICP in any continuous 12" length of weld: 2" 50 mm

INCOMPLETE FUSIONMaximum length of an individual indication of IF: 1 inch or 25mmMaximum length of IF in 8% of weld: N/A since total weld exceeds 12 inchesMaximum length of indications of IF in any continuous 12" length of weld: 1" 25 mm

INCOMPLETE FUSION DUE TO COLD LAPMaximum length of individual indications of IFD: 2 inches or 50mmMaximum length of IFD in 8% of weld: 81.4807 mmMaximum length of indications of IFD in any continuous 12" length of weld: 2" 25 mm

INTERNAL CONCAVITY Any length of IC is acceptable, provided the density of the radiographic image of the internal concavity does not exceed that of the thinnest adjacent parent material. For areas that exceed the density of thethinnest adjacent parent material, the criteria for burn through are applicable.

BURN - THROUGHMaximum dimension of BT's image : unacceptable if it exceeds that of the thinnest adjacent parent metal.Maximum dimension of BT: 1/4" or 6mmMaximum dimension is unacceptable if: it exceeds the thinner of the nonnal wall thickness joined, and the density

of the BT's image exceeds that of the thinnest adjacent parent material.The sum of the max dimensions of separate BBT's whose image density exceeds that of the thinnest adjacent parentmaterial exceeds 1/2 inch or 13mm in any continuous 12" length of weld or the total weld length(whichever is less).

API - 110412" s/120 - 1.00" Wall

Page 1 of 2

Page 91: NDT Code Book Made Easy

API - 110412" s/120 - 1.00" Wall

SLAG INCLUSIONSElongated slag inclusions (ESI)Maximum length of an ESI: 2 inches or 50mmParallel ESI indications (Wagon Tracks) shall be considered a single indication unless the width of either of them exceed1/32" or 0.8mm. In that event they shall be considered separate indications.Maximum length of ESI indications in any continuous 12" length of weld: 2" 50 mmMaximum width of an individual ESI indication: 1/16" or 1.6mmIsolated slag inclusions (ISI)Maximum length of ISI indications in any continuous 12" length of weld: 1/2" 13 mmMaximum width of an ISI indication: 1/8" or 3mmMaximum length of ESI and ISI in 8% of weld: 81.4807 mm

POROSITY Individual or Scattered Porosity.Maximum size of an individual pore: 1/8" or 3mmThe size of an individual pore exceeds 25% of the thinner of the nonimal wall thickness joined.The distribution of scattered porosity exceeds the concentration permitted in Figures 19 or 20.Cluster Porosity (CP)Maximum diameter of the cluster: 1/2 inch or 13mmMaximum length of CP indications in any continuous 12" length of weweld: 1/2" 13 mmMaximum length of an individual pore within a cluster: 1/16 inch or 2mmHollow Bead Porosity (HB)Maximum length of an individual indication of HB: 1/2 inch or 13mmMaximum length of HB indications in any continuous 12" length of weld: 2" 50 mmMaximum length of HB in 8% of weld: 81.4807 mmNOTE: The weld is unacceptable if individual indications of HB, each greater than 1/4 inch or 6mm in length, are seperated by less than 2 inches or 50 mm.

CRACKSNote: Any crack which is not a shallow crater crack or star crack is unacceptable.Maximum length of shallow crater cracks or star cracks: 5/32 inch or 4mm

UNDERCUTTINGUndercutting adjacent to the cover pass (EU) and Undercutting adjacent to the root pass (IU)Maximum length of EU and IU indications (in any combination) in a 12 inch length of weld: 2" 50 mmMaximum length of EU and IU indications: 6.683125" 169.7514 mm (This value is 1/6 th of the total weld length)

ACCUMULATION OF IMPERFECTIONSMaximum length of AI indications in any continuous 12 inch or 300 mm length of weld: 2" 50 mmMaximum length of AI indications of 8% of weld: 81.4807 mm

RADIOGRAPHIC INFOPipe O.D. in inches: 12.750 "Amount of Penetrameters required for each shot: 1 penetrameter 1" from the end of film and 1 penny in the center.Total weld length: 40.09875" 1018.5083 mmCassette size to complete weld in most efficient way: 3.5 x 17" 4.5 x 17"Amount of shots to complete weld with 1" on each side of readable film: 48% of weld: 3.2079" 81.4807 mmHole penetrameters are adjacent to the weld and Wire penetrameters are parallel to the weld.

Page 2 of 2

Page 92: NDT Code Book Made Easy

PENETRAMETER SELECTIONNote: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Wire: 0.020 Esn. Wire: B3 S/S Hole: 25

F/S Wire: 0.016 Esn. Wire: B4 F/S Hole: 20Welds with reinforcement: S/S Wire: 0.025 Esn. Wire: B2 S/S Hole: 30

F/S Wire: 0.020 Esn. Wire: B3 F/S Hole: 25Maximum allowable reinforcement: 0.0625"/per sideMaximum reinforcement with DWE/SWV: 0.125" Total of walls + reinforcement: 2.125" 53.9750 mmMaximum reinforcement with DWE/DWV: 0.125" Total of walls + reinforcement: 2.125" 53.9750 mmMaximum reinforcement with SWE/SWV: 0.0625" Total of wall + reinforcement: 1.0625" 26.9875 mm

INADEQUATE PENETRATION WITHOUT HIGH LOWMaximum length of individual indication of IP : 1 inch or 25mmMaximum length of IP in 8% of weld: N/A since total weld exceeds 12 inchesMaximum length of indications in any continuous 12" length of weld: 1" 25 mm

INADEQUATE PENETRATION DUE TO HIGH LOWMaximum length of individual indication of IPD: 2 inches or 50mmMaximum length of indications of IPD in any continuous 12" length of weld: 3" 75 mm

INADEQUATE CROSS PENETRATIONMaximum length of an individual indication of ICP: 2 inches or 50mmMaximum length of indications of ICP in any continuous 12" length of weld: 2" 50 mm

INCOMPLETE FUSIONMaximum length of an individual indication of IF: 1 inch or 25mmMaximum length of IF in 8% of weld: N/A since total weld exceeds 12 inchesMaximum length of indications of IF in any continuous 12" length of weld: 1" 25 mm

INCOMPLETE FUSION DUE TO COLD LAPMaximum length of individual indications of IFD: 2 inches or 50mmMaximum length of IFD in 8% of weld: 81.4807 mmMaximum length of indications of IFD in any continuous 12" length of weld: 2" 25 mm

INTERNAL CONCAVITY Any length of IC is acceptable, provided the density of the radiographic image of the internal concavity does not exceed that of the thinnest adjacent parent material. For areas that exceed the density of thethinnest adjacent parent material, the criteria for burn through are applicable.

BURN - THROUGHMaximum dimension of BT's image : unacceptable if it exceeds that of the thinnest adjacent parent metal.Maximum dimension of BT: 1/4" or 6mmMaximum dimension is unacceptable if: it exceeds the thinner of the nonnal wall thickness joined, and the density

of the BT's image exceeds that of the thinnest adjacent parent material.The sum of the max dimensions of separate BBT's whose image density exceeds that of the thinnest adjacent parentmaterial exceeds 1/2 inch or 13mm in any continuous 12" length of weld or the total weld length(whichever is less).

API - 110412" s/120 - 1.00" Wall

Page 1 of 2

Page 93: NDT Code Book Made Easy

API - 110412" s/120 - 1.00" Wall

SLAG INCLUSIONSElongated slag inclusions (ESI)Maximum length of an ESI: 2 inches or 50mmParallel ESI indications (Wagon Tracks) shall be considered a single indication unless the width of either of them exceed1/32" or 0.8mm. In that event they shall be considered separate indications.Maximum length of ESI indications in any continuous 12" length of weld: 2" 50 mmMaximum width of an individual ESI indication: 1/16" or 1.6mmIsolated slag inclusions (ISI)Maximum length of ISI indications in any continuous 12" length of weld: 1/2" 13 mmMaximum width of an ISI indication: 1/8" or 3mmMaximum length of ESI and ISI in 8% of weld: 81.4807 mm

POROSITY Individual or Scattered Porosity.Maximum size of an individual pore: 1/8" or 3mmThe size of an individual pore exceeds 25% of the thinner of the nonimal wall thickness joined.The distribution of scattered porosity exceeds the concentration permitted in Figures 19 or 20.Cluster Porosity (CP)Maximum diameter of the cluster: 1/2 inch or 13mmMaximum length of CP indications in any continuous 12" length of weweld: 1/2" 13 mmMaximum length of an individual pore within a cluster: 1/16 inch or 2mmHollow Bead Porosity (HB)Maximum length of an individual indication of HB: 1/2 inch or 13mmMaximum length of HB indications in any continuous 12" length of weld: 2" 50 mmMaximum length of HB in 8% of weld: 81.4807 mmNOTE: The weld is unacceptable if individual indications of HB, each greater than 1/4 inch or 6mm in length, are seperated by less than 2 inches or 50 mm.

CRACKSNote: Any crack which is not a shallow crater crack or star crack is unacceptable.Maximum length of shallow crater cracks or star cracks: 5/32 inch or 4mm

UNDERCUTTINGUndercutting adjacent to the cover pass (EU) and Undercutting adjacent to the root pass (IU)Maximum length of EU and IU indications (in any combination) in a 12 inch length of weld: 2" 50 mmMaximum length of EU and IU indications: 6.683125" 169.7514 mm (This value is 1/6 th of the total weld length)

ACCUMULATION OF IMPERFECTIONSMaximum length of AI indications in any continuous 12 inch or 300 mm length of weld: 2" 50 mmMaximum length of AI indications of 8% of weld: 81.4807 mm

RADIOGRAPHIC INFOPipe O.D. in inches: 12.750 "Amount of Penetrameters required for each shot: 1 penetrameter 1" from the end of film and 1 penny in the center.Total weld length: 40.09875" 1018.5083 mmCassette size to complete weld in most efficient way: 3.5 x 17" 4.5 x 17"Amount of shots to complete weld with 1" on each side of readable film: 48% of weld: 3.2079" 81.4807 mmHole penetrameters are adjacent to the weld and Wire penetrameters are parallel to the weld.

Page 2 of 2

Page 94: NDT Code Book Made Easy

PENETRAMETER SELECTIONNote: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Wire: 0.025 Esn. Wire: B2 S/S Hole: 30

F/S Wire: 0.020 Esn. Wire: B3 F/S Hole: 25Welds with reinforcement: S/S Wire: 0.025 Esn. Wire: B2 S/S Hole: 30

F/S Wire: 0.020 Esn. Wire: B3 F/S Hole: 25Maximum allowable reinforcement: 0.0625"/per sideMaximum reinforcement with DWE/SWV: 0.125" Total of walls + reinforcement: 2.749" 69.8246 mmMaximum reinforcement with DWE/DWV: 0.125" Total of walls + reinforcement: 2.749" 69.8246 mmMaximum reinforcement with SWE/SWV: 0.0625" Total of wall + reinforcement: 1.3745" 34.9123 mm

INADEQUATE PENETRATION WITHOUT HIGH LOWMaximum length of individual indication of IP : 1 inch or 25mmMaximum length of IP in 8% of weld: N/A since total weld exceeds 12 inchesMaximum length of indications in any continuous 12" length of weld: 1" 25 mm

INADEQUATE PENETRATION DUE TO HIGH LOWMaximum length of individual indication of IPD: 2 inches or 50mmMaximum length of indications of IPD in any continuous 12" length of weld: 3" 75 mm

INADEQUATE CROSS PENETRATIONMaximum length of an individual indication of ICP: 2 inches or 50mmMaximum length of indications of ICP in any continuous 12" length of weld: 2" 50 mm

INCOMPLETE FUSIONMaximum length of an individual indication of IF: 1 inch or 25mmMaximum length of IF in 8% of weld: N/A since total weld exceeds 12 inchesMaximum length of indications of IF in any continuous 12" length of weld: 1" 25 mm

INCOMPLETE FUSION DUE TO COLD LAPMaximum length of individual indications of IFD: 2 inches or 50mmMaximum length of IFD in 8% of weld: 81.4807 mmMaximum length of indications of IFD in any continuous 12" length of weld: 2" 25 mm

INTERNAL CONCAVITY Any length of IC is acceptable, provided the density of the radiographic image of the internal concavity does not exceed that of the thinnest adjacent parent material. For areas that exceed the density of thethinnest adjacent parent material, the criteria for burn through are applicable.

BURN - THROUGHMaximum dimension of BT's image : unacceptable if it exceeds that of the thinnest adjacent parent metal.Maximum dimension of BT: 1/4" or 6mmMaximum dimension is unacceptable if: it exceeds the thinner of the nonnal wall thickness joined, and the density

of the BT's image exceeds that of the thinnest adjacent parent material.The sum of the max dimensions of separate BBT's whose image density exceeds that of the thinnest adjacent parentmaterial exceeds 1/2 inch or 13mm in any continuous 12" length of weld or the total weld length(whichever is less).

API - 110412" s/160 - 1.312" Wall

Page 1 of 2

Page 95: NDT Code Book Made Easy

API - 110412" s/160 - 1.312" Wall

SLAG INCLUSIONSElongated slag inclusions (ESI)Maximum length of an ESI: 2 inches or 50mmParallel ESI indications (Wagon Tracks) shall be considered a single indication unless the width of either of them exceed1/32" or 0.8mm. In that event they shall be considered separate indications.Maximum length of ESI indications in any continuous 12" length of weld: 2" 50 mmMaximum width of an individual ESI indication: 1/16" or 1.6mmIsolated slag inclusions (ISI)Maximum length of ISI indications in any continuous 12" length of weld: 1/2" 13 mmMaximum width of an ISI indication: 1/8" or 3mmMaximum length of ESI and ISI in 8% of weld: 81.4807 mm

POROSITY Individual or Scattered Porosity.Maximum size of an individual pore: 1/8" or 3mmThe size of an individual pore exceeds 25% of the thinner of the nonimal wall thickness joined.The distribution of scattered porosity exceeds the concentration permitted in Figures 19 or 20.Cluster Porosity (CP)Maximum diameter of the cluster: 1/2 inch or 13mmMaximum length of CP indications in any continuous 12" length of weweld: 1/2" 13 mmMaximum length of an individual pore within a cluster: 1/16 inch or 2mmHollow Bead Porosity (HB)Maximum length of an individual indication of HB: 1/2 inch or 13mmMaximum length of HB indications in any continuous 12" length of weld: 2" 50 mmMaximum length of HB in 8% of weld: 81.4807 mmNOTE: The weld is unacceptable if individual indications of HB, each greater than 1/4 inch or 6mm in length, are seperated by less than 2 inches or 50 mm.

CRACKSNote: Any crack which is not a shallow crater crack or star crack is unacceptable.Maximum length of shallow crater cracks or star cracks: 5/32 inch or 4mm

UNDERCUTTINGUndercutting adjacent to the cover pass (EU) and Undercutting adjacent to the root pass (IU)Maximum length of EU and IU indications (in any combination) in a 12 inch length of weld: 2" 50 mmMaximum length of EU and IU indications: 6.683125" 169.7514 mm (This value is 1/6 th of the total weld length)

ACCUMULATION OF IMPERFECTIONSMaximum length of AI indications in any continuous 12 inch or 300 mm length of weld: 2" 50 mmMaximum length of AI indications of 8% of weld: 81.4807 mm

RADIOGRAPHIC INFOPipe O.D. in inches: 12.750 "Amount of Penetrameters required for each shot: 1 penetrameter 1" from the end of film and 1 penny in the center.Total weld length: 40.09875" 1018.5083 mmCassette size to complete weld in most efficient way: 3.5 x 17" 4.5 x 17"Amount of shots to complete weld with 1" on each side of readable film: 58% of weld: 3.2079" 81.4807 mmHole penetrameters are adjacent to the weld and Wire penetrameters are parallel to the weld.

Page 2 of 2

Page 96: NDT Code Book Made Easy

PENETRAMETER SELECTIONNote: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Wire: 0.008 Esn. Wire: A2 S/S Hole: 12

F/S Wire: 0.006 Esn. Wire: A3 F/S Hole: 10Welds with reinforcement: S/S Wire: 0.010 Esn. Wire: A1 or B6 S/S Hole: 15

F/S Wire: 0.008 Esn. Wire: A2 F/S Hole: 12Maximum allowable reinforcement: 0.0625"/per sideMaximum reinforcement with DWE/SWV: 0.125" Total of walls + reinforcement: .625" 15.8750 mmMaximum reinforcement with DWE/DWV: 0.125" Total of walls + reinforcement: .625" 15.8750 mmMaximum reinforcement with SWE/SWV: 0.0625" Total of wall + reinforcement: .3125" 7.9375 mm

INADEQUATE PENETRATION WITHOUT HIGH LOWMaximum length of individual indication of IP : 1 inch or 25mmMaximum length of IP in 8% of weld: N/A since total weld exceeds 12 inchesMaximum length of indications in any continuous 12" length of weld: 1" 25 mm

INADEQUATE PENETRATION DUE TO HIGH LOWMaximum length of individual indication of IPD: 2 inches or 50mmMaximum length of indications of IPD in any continuous 12" length of weld: 3" 75 mm

INADEQUATE CROSS PENETRATIONMaximum length of an individual indication of ICP: 2 inches or 50mmMaximum length of indications of ICP in any continuous 12" length of weld: 2" 50 mm

INCOMPLETE FUSIONMaximum length of an individual indication of IF: 1 inch or 25mmMaximum length of IF in 8% of weld: N/A since total weld exceeds 12 inchesMaximum length of indications of IF in any continuous 12" length of weld: 1" 25 mm

INCOMPLETE FUSION DUE TO COLD LAPMaximum length of individual indications of IFD: 2 inches or 50mmMaximum length of IFD in 8% of weld: 89.4690 mmMaximum length of indications of IFD in any continuous 12" length of weld: 2" 25 mm

INTERNAL CONCAVITY Any length of IC is acceptable, provided the density of the radiographic image of the internal concavity does not exceed that of the thinnest adjacent parent material. For areas that exceed the density of thethinnest adjacent parent material, the criteria for burn through are applicable.

BURN - THROUGHMaximum dimension of BT's image : unacceptable if it exceeds that of the thinnest adjacent parent metal.Maximum dimension of BT: 1/4" or 6mmMaximum dimension is unacceptable if: it exceeds the thinner of the nonnal wall thickness joined, and the density

of the BT's image exceeds that of the thinnest adjacent parent material.The sum of the max dimensions of separate BBT's whose image density exceeds that of the thinnest adjacent parentmaterial exceeds 1/2 inch or 13mm in any continuous 12" length of weld or the total weld length(whichever is less).

API - 110414" s/10 - .250" Wall

Page 1 of 2

Page 97: NDT Code Book Made Easy

API - 110414" s/10 - .250" Wall

SLAG INCLUSIONSElongated slag inclusions (ESI)Maximum length of an ESI: 2 inches or 50mmParallel ESI indications (Wagon Tracks) shall be considered a single indication unless the width of either of them exceed1/32" or 0.8mm. In that event they shall be considered separate indications.Maximum length of ESI indications in any continuous 12" length of weld: 2" 50 mmMaximum width of an individual ESI indication: 1/16" or 1.6mmIsolated slag inclusions (ISI)Maximum length of ISI indications in any continuous 12" length of weld: 1/2" 13 mmMaximum width of an ISI indication: 1/8" or 3mmMaximum length of ESI and ISI in 8% of weld: 89.4690 mm

POROSITY Individual or Scattered Porosity.Maximum size of an individual pore: 1/8" or 3mmThe size of an individual pore exceeds 25% of the thinner of the nonimal wall thickness joined.The distribution of scattered porosity exceeds the concentration permitted in Figures 19 or 20.Cluster Porosity (CP)Maximum diameter of the cluster: 1/2 inch or 13mmMaximum length of CP indications in any continuous 12" length of weweld: 1/2" 13 mmMaximum length of an individual pore within a cluster: 1/16 inch or 2mmHollow Bead Porosity (HB)Maximum length of an individual indication of HB: 1/2 inch or 13mmMaximum length of HB indications in any continuous 12" length of weld: 2" 50 mmMaximum length of HB in 8% of weld: 89.4690 mmNOTE: The weld is unacceptable if individual indications of HB, each greater than 1/4 inch or 6mm in length, are seperated by less than 2 inches or 50 mm.

CRACKSNote: Any crack which is not a shallow crater crack or star crack is unacceptable.Maximum length of shallow crater cracks or star cracks: 5/32 inch or 4mm

UNDERCUTTINGUndercutting adjacent to the cover pass (EU) and Undercutting adjacent to the root pass (IU)Maximum length of EU and IU indications (in any combination) in a 12 inch length of weld: 2" 50 mmMaximum length of EU and IU indications: 7.3383" 186.3937 mm (This value is 1/6 th of the total weld length)

ACCUMULATION OF IMPERFECTIONSMaximum length of AI indications in any continuous 12 inch or 300 mm length of weld: 2" 50 mmMaximum length of AI indications of 8% of weld: 89.4690 mm

RADIOGRAPHIC INFOPipe O.D. in inches: 14.00"Amount of Penetrameters required for each shot: 1 penetrameter 1" from the end of film and 1 penny in the center.Total weld length: 44.03 1118.3620 mmCassette size to complete weld in most efficient way: 3.5 x 17" 4.5 x 17"Amount of shots to complete weld with 1" on each side of readable film: 38% of weld: 3.5224" 89.4690 mmHole penetrameters are adjacent to the weld and Wire penetrameters are parallel to the weld.

Page 2 of 2

Page 98: NDT Code Book Made Easy

PENETRAMETER SELECTIONNote: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Wire: 0.013 Esn. Wire: B5 S/S Hole: 17

F/S Wire: 0.010 Esn. Wire: A1 or B6 F/S Hole: 15Welds with reinforcement: S/S Wire: 0.016 Esn. Wire: B4 S/S Hole: 20

F/S Wire: 0.013 Esn. Wire: B5 F/S Hole: 17Maximum allowable reinforcement: 0.0625"/per sideMaximum reinforcement with DWE/SWV: 0.125" Total of walls + reinforcement: .999" 25.3746 mmMaximum reinforcement with DWE/DWV: 0.125" Total of walls + reinforcement: .999" 25.3746 mmMaximum reinforcement with SWE/SWV: 0.0625" Total of wall + reinforcement: .562" 14.2748 mm

INADEQUATE PENETRATION WITHOUT HIGH LOWMaximum length of individual indication of IP : 1 inch or 25mmMaximum length of IP in 8% of weld: N/A since total weld exceeds 12 inchesMaximum length of indications in any continuous 12" length of weld: 1" 25 mm

INADEQUATE PENETRATION DUE TO HIGH LOWMaximum length of individual indication of IPD: 2 inches or 50mmMaximum length of indications of IPD in any continuous 12" length of weld: 3" 75 mm

INADEQUATE CROSS PENETRATIONMaximum length of an individual indication of ICP: 2 inches or 50mmMaximum length of indications of ICP in any continuous 12" length of weld: 2" 50 mm

INCOMPLETE FUSIONMaximum length of an individual indication of IF: 1 inch or 25mmMaximum length of IF in 8% of weld: N/A since total weld exceeds 12 inchesMaximum length of indications of IF in any continuous 12" length of weld: 1" 25 mm

INCOMPLETE FUSION DUE TO COLD LAPMaximum length of individual indications of IFD: 2 inches or 50mmMaximum length of IFD in 8% of weld: 89.4690 mmMaximum length of indications of IFD in any continuous 12" length of weld: 2" 25 mm

INTERNAL CONCAVITY Any length of IC is acceptable, provided the density of the radiographic image of the internal concavity does not exceed that of the thinnest adjacent parent material. For areas that exceed the density of thethinnest adjacent parent material, the criteria for burn through are applicable.

BURN - THROUGHMaximum dimension of BT's image : unacceptable if it exceeds that of the thinnest adjacent parent metal.Maximum dimension of BT: 1/4" or 6mmMaximum dimension is unacceptable if: it exceeds the thinner of the nonnal wall thickness joined, and the density

of the BT's image exceeds that of the thinnest adjacent parent material.The sum of the max dimensions of separate BBT's whose image density exceeds that of the thinnest adjacent parentmaterial exceeds 1/2 inch or 13mm in any continuous 12" length of weld or the total weld length(whichever is less).

API - 110414" s/40 - .437" Wall

Page 1 of 2

Page 99: NDT Code Book Made Easy

API - 110414" s/40 - .437" Wall

SLAG INCLUSIONSElongated slag inclusions (ESI)Maximum length of an ESI: 2 inches or 50mmParallel ESI indications (Wagon Tracks) shall be considered a single indication unless the width of either of them exceed1/32" or 0.8mm. In that event they shall be considered separate indications.Maximum length of ESI indications in any continuous 12" length of weld: 2" 50 mmMaximum width of an individual ESI indication: 1/16" or 1.6mmIsolated slag inclusions (ISI)Maximum length of ISI indications in any continuous 12" length of weld: 1/2" 13 mmMaximum width of an ISI indication: 1/8" or 3mmMaximum length of ESI and ISI in 8% of weld: 89.4690 mm

POROSITY Individual or Scattered Porosity.Maximum size of an individual pore: 1/8" or 3mmThe size of an individual pore exceeds 25% of the thinner of the nonimal wall thickness joined.The distribution of scattered porosity exceeds the concentration permitted in Figures 19 or 20.Cluster Porosity (CP)Maximum diameter of the cluster: 1/2 inch or 13mmMaximum length of CP indications in any continuous 12" length of weweld: 1/2" 13 mmMaximum length of an individual pore within a cluster: 1/16 inch or 2mmHollow Bead Porosity (HB)Maximum length of an individual indication of HB: 1/2 inch or 13mmMaximum length of HB indications in any continuous 12" length of weld: 2" 50 mmMaximum length of HB in 8% of weld: 89.4690 mmNOTE: The weld is unacceptable if individual indications of HB, each greater than 1/4 inch or 6mm in length, are seperated by less than 2 inches or 50 mm.

CRACKSNote: Any crack which is not a shallow crater crack or star crack is unacceptable.Maximum length of shallow crater cracks or star cracks: 5/32 inch or 4mm

UNDERCUTTINGUndercutting adjacent to the cover pass (EU) and Undercutting adjacent to the root pass (IU)Maximum length of EU and IU indications (in any combination) in a 12 inch length of weld: 2" 50 mmMaximum length of EU and IU indications: 7.3383" 186.3937 mm (This value is 1/6 th of the total weld length)

ACCUMULATION OF IMPERFECTIONSMaximum length of AI indications in any continuous 12 inch or 300 mm length of weld: 2" 50 mmMaximum length of AI indications of 8% of weld: 89.4690 mm

RADIOGRAPHIC INFOPipe O.D. in inches: 14.00"Amount of Penetrameters required for each shot: 1 penetrameter 1" from the end of film and 1 penny in the center.Total weld length: 44.03 1118.3620 mmCassette size to complete weld in most efficient way: 3.5 x 17" 4.5 x 17"Amount of shots to complete weld with 1" on each side of readable film: 38% of weld: 3.5224" 89.4690 mmHole penetrameters are adjacent to the weld and Wire penetrameters are parallel to the weld.

Page 2 of 2

Page 100: NDT Code Book Made Easy

PENETRAMETER SELECTIONNote: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Wire: 0.010 Esn. Wire: A1 or B6 S/S Hole: 15

F/S Wire: 0.008 Esn. Wire: A2 F/S Hole: 12Welds with reinforcement: S/S Wire: 0.013 Esn. Wire: B5 S/S Hole: 17

F/S Wire: 0.010 Esn. Wire: A1 or B6 F/S Hole: 15Maximum allowable reinforcement: 0.0625"/per sideMaximum reinforcement with DWE/SWV: 0.125" Total of walls + reinforcement: .875" 22.2250 mmMaximum reinforcement with DWE/DWV: 0.125" Total of walls + reinforcement: .875" 22.2250 mmMaximum reinforcement with SWE/SWV: 0.0625" Total of wall + reinforcement: .500" 12.7000 mm

INADEQUATE PENETRATION WITHOUT HIGH LOWMaximum length of individual indication of IP : 1 inch or 25mmMaximum length of IP in 8% of weld: N/A since total weld exceeds 12 inchesMaximum length of indications in any continuous 12" length of weld: 1" 25 mm

INADEQUATE PENETRATION DUE TO HIGH LOWMaximum length of individual indication of IPD: 2 inches or 50mmMaximum length of indications of IPD in any continuous 12" length of weld: 3" 75 mm

INADEQUATE CROSS PENETRATIONMaximum length of an individual indication of ICP: 2 inches or 50mmMaximum length of indications of ICP in any continuous 12" length of weld: 2" 50 mm

INCOMPLETE FUSIONMaximum length of an individual indication of IF: 1 inch or 25mmMaximum length of IF in 8% of weld: N/A since total weld exceeds 12 inchesMaximum length of indications of IF in any continuous 12" length of weld: 1" 25 mm

INCOMPLETE FUSION DUE TO COLD LAPMaximum length of individual indications of IFD: 2 inches or 50mmMaximum length of IFD in 8% of weld: 89.4690 mmMaximum length of indications of IFD in any continuous 12" length of weld: 2" 25 mm

INTERNAL CONCAVITY Any length of IC is acceptable, provided the density of the radiographic image of the internal concavity does not exceed that of the thinnest adjacent parent material. For areas that exceed the density of thethinnest adjacent parent material, the criteria for burn through are applicable.

BURN - THROUGHMaximum dimension of BT's image : unacceptable if it exceeds that of the thinnest adjacent parent metal.Maximum dimension of BT: 1/4" or 6mmMaximum dimension is unacceptable if: it exceeds the thinner of the nonnal wall thickness joined, and the density

of the BT's image exceeds that of the thinnest adjacent parent material.The sum of the max dimensions of separate BBT's whose image density exceeds that of the thinnest adjacent parentmaterial exceeds 1/2 inch or 13mm in any continuous 12" length of weld or the total weld length(whichever is less).

API - 110414" Standard - .375" Wall

Page 1 of 2

Page 101: NDT Code Book Made Easy

API - 110414" Standard - .375" Wall

SLAG INCLUSIONSElongated slag inclusions (ESI)Maximum length of an ESI: 2 inches or 50mmParallel ESI indications (Wagon Tracks) shall be considered a single indication unless the width of either of them exceed1/32" or 0.8mm. In that event they shall be considered separate indications.Maximum length of ESI indications in any continuous 12" length of weld: 2" 50 mmMaximum width of an individual ESI indication: 1/16" or 1.6mmIsolated slag inclusions (ISI)Maximum length of ISI indications in any continuous 12" length of weld: 1/2" 13 mmMaximum width of an ISI indication: 1/8" or 3mmMaximum length of ESI and ISI in 8% of weld: 89.4690 mm

POROSITY Individual or Scattered Porosity.Maximum size of an individual pore: 1/8" or 3mmThe size of an individual pore exceeds 25% of the thinner of the nonimal wall thickness joined.The distribution of scattered porosity exceeds the concentration permitted in Figures 19 or 20.Cluster Porosity (CP)Maximum diameter of the cluster: 1/2 inch or 13mmMaximum length of CP indications in any continuous 12" length of weweld: 1/2" 13 mmMaximum length of an individual pore within a cluster: 1/16 inch or 2mmHollow Bead Porosity (HB)Maximum length of an individual indication of HB: 1/2 inch or 13mmMaximum length of HB indications in any continuous 12" length of weld: 2" 50 mmMaximum length of HB in 8% of weld: 89.4690 mmNOTE: The weld is unacceptable if individual indications of HB, each greater than 1/4 inch or 6mm in length, are seperated by less than 2 inches or 50 mm.

CRACKSNote: Any crack which is not a shallow crater crack or star crack is unacceptable.Maximum length of shallow crater cracks or star cracks: 5/32 inch or 4mm

UNDERCUTTINGUndercutting adjacent to the cover pass (EU) and Undercutting adjacent to the root pass (IU)Maximum length of EU and IU indications (in any combination) in a 12 inch length of weld: 2" 50 mmMaximum length of EU and IU indications: 7.3383" 186.3937 mm (This value is 1/6 th of the total weld length)

ACCUMULATION OF IMPERFECTIONSMaximum length of AI indications in any continuous 12 inch or 300 mm length of weld: 2" 50 mmMaximum length of AI indications of 8% of weld: 89.4690 mm

RADIOGRAPHIC INFOPipe O.D. in inches: 14.00"Amount of Penetrameters required for each shot: 1 penetrameter 1" from the end of film and 1 penny in the center.Total weld length: 44.03 1118.3620 mmCassette size to complete weld in most efficient way: 3.5 x 17" 4.5 x 17"Amount of shots to complete weld with 1" on each side of readable film: 38% of weld: 3.5224" 89.4690 mmHole penetrameters are adjacent to the weld and Wire penetrameters are parallel to the weld.

Page 2 of 2

Page 102: NDT Code Book Made Easy

PENETRAMETER SELECTIONNote: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Wire: 0.016 Esn. Wire: B4 S/S Hole: 20

F/S Wire: 0.013 Esn. Wire: B5 F/S Hole: 17Welds with reinforcement: S/S Wire: 0.020 Esn. Wire: B3 S/S Hole: 25

F/S Wire: 0.016 Esn. Wire: B4 F/S Hole: 20Maximum allowable reinforcement: 0.0625"/per sideMaximum reinforcement with DWE/SWV: 0.125" Total of walls + reinforcement: 1.625" 41.2750 mmMaximum reinforcement with DWE/DWV: 0.125" Total of walls + reinforcement: 1.625" 41.2750 mmMaximum reinforcement with SWE/SWV: 0.0625" Total of wall + reinforcement: .8125" 20.6375 mm

INADEQUATE PENETRATION WITHOUT HIGH LOWMaximum length of individual indication of IP : 1 inch or 25mmMaximum length of IP in 8% of weld: N/A since total weld exceeds 12 inchesMaximum length of indications in any continuous 12" length of weld: 1" 25 mm

INADEQUATE PENETRATION DUE TO HIGH LOWMaximum length of individual indication of IPD: 2 inches or 50mmMaximum length of indications of IPD in any continuous 12" length of weld: 3" 75 mm

INADEQUATE CROSS PENETRATIONMaximum length of an individual indication of ICP: 2 inches or 50mmMaximum length of indications of ICP in any continuous 12" length of weld: 2" 50 mm

INCOMPLETE FUSIONMaximum length of an individual indication of IF: 1 inch or 25mmMaximum length of IF in 8% of weld: N/A since total weld exceeds 12 inchesMaximum length of indications of IF in any continuous 12" length of weld: 1" 25 mm

INCOMPLETE FUSION DUE TO COLD LAPMaximum length of individual indications of IFD: 2 inches or 50mmMaximum length of IFD in 8% of weld: 89.4690 mmMaximum length of indications of IFD in any continuous 12" length of weld: 2" 25 mm

INTERNAL CONCAVITY Any length of IC is acceptable, provided the density of the radiographic image of the internal concavity does not exceed that of the thinnest adjacent parent material. For areas that exceed the density of thethinnest adjacent parent material, the criteria for burn through are applicable.

BURN - THROUGHMaximum dimension of BT's image : unacceptable if it exceeds that of the thinnest adjacent parent metal.Maximum dimension of BT: 1/4" or 6mmMaximum dimension is unacceptable if: it exceeds the thinner of the nonnal wall thickness joined, and the density

of the BT's image exceeds that of the thinnest adjacent parent material.The sum of the max dimensions of separate BBT's whose image density exceeds that of the thinnest adjacent parentmaterial exceeds 1/2 inch or 13mm in any continuous 12" length of weld or the total weld length(whichever is less).

API - 110414" s/80 - .750" Wall

Page 1 of 2

Page 103: NDT Code Book Made Easy

API - 110414" s/80 - .750" Wall

SLAG INCLUSIONSElongated slag inclusions (ESI)Maximum length of an ESI: 2 inches or 50mmParallel ESI indications (Wagon Tracks) shall be considered a single indication unless the width of either of them exceed1/32" or 0.8mm. In that event they shall be considered separate indications.Maximum length of ESI indications in any continuous 12" length of weld: 2" 50 mmMaximum width of an individual ESI indication: 1/16" or 1.6mmIsolated slag inclusions (ISI)Maximum length of ISI indications in any continuous 12" length of weld: 1/2" 13 mmMaximum width of an ISI indication: 1/8" or 3mmMaximum length of ESI and ISI in 8% of weld: 89.4690 mm

POROSITY Individual or Scattered Porosity.Maximum size of an individual pore: 1/8" or 3mmThe size of an individual pore exceeds 25% of the thinner of the nonimal wall thickness joined.The distribution of scattered porosity exceeds the concentration permitted in Figures 19 or 20.Cluster Porosity (CP)Maximum diameter of the cluster: 1/2 inch or 13mmMaximum length of CP indications in any continuous 12" length of weweld: 1/2" 13 mmMaximum length of an individual pore within a cluster: 1/16 inch or 2mmHollow Bead Porosity (HB)Maximum length of an individual indication of HB: 1/2 inch or 13mmMaximum length of HB indications in any continuous 12" length of weld: 2" 50 mmMaximum length of HB in 8% of weld: 89.4690 mmNOTE: The weld is unacceptable if individual indications of HB, each greater than 1/4 inch or 6mm in length, are seperated by less than 2 inches or 50 mm.

CRACKSNote: Any crack which is not a shallow crater crack or star crack is unacceptable.Maximum length of shallow crater cracks or star cracks: 5/32 inch or 4mm

UNDERCUTTINGUndercutting adjacent to the cover pass (EU) and Undercutting adjacent to the root pass (IU)Maximum length of EU and IU indications (in any combination) in a 12 inch length of weld: 2" 50 mmMaximum length of EU and IU indications: 7.3383" 186.3937 mm (This value is 1/6 th of the total weld length)

ACCUMULATION OF IMPERFECTIONSMaximum length of AI indications in any continuous 12 inch or 300 mm length of weld: 2" 50 mmMaximum length of AI indications of 8% of weld: 89.4690 mm

RADIOGRAPHIC INFOPipe O.D. in inches: 14.00"Amount of Penetrameters required for each shot: 1 penetrameter 1" from the end of film and 1 penny in the center.Total weld length: 44.03 1118.3620 mmCassette size to complete weld in most efficient way: 3.5 x 17" 4.5 x 17"Amount of shots to complete weld with 1" on each side of readable film: 48% of weld: 3.5224" 89.4690 mmHole penetrameters are adjacent to the weld and Wire penetrameters are parallel to the weld.

Page 2 of 2

Page 104: NDT Code Book Made Easy

PENETRAMETER SELECTIONNote: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Wire: 0.013 Esn. Wire: B5 S/S Hole: 17

F/S Wire: 0.010 Esn. Wire: A1 or B6 F/S Hole: 15Welds with reinforcement: S/S Wire: 0.016 Esn. Wire: B4 S/S Hole: 20

F/S Wire: 0.013 Esn. Wire: B5 F/S Hole: 17Maximum allowable reinforcement: 0.0625"/per sideMaximum reinforcement with DWE/SWV: 0.125" Total of walls + reinforcement: 1.125" 28.5750 mmMaximum reinforcement with DWE/DWV: 0.125" Total of walls + reinforcement: 1.125" 28.5750 mmMaximum reinforcement with SWE/SWV: 0.0625" Total of wall + reinforcement: .5625" 14.2875 mm

INADEQUATE PENETRATION WITHOUT HIGH LOWMaximum length of individual indication of IP : 1 inch or 25mmMaximum length of IP in 8% of weld: N/A since total weld exceeds 12 inchesMaximum length of indications in any continuous 12" length of weld: 1" 25 mm

INADEQUATE PENETRATION DUE TO HIGH LOWMaximum length of individual indication of IPD: 2 inches or 50mmMaximum length of indications of IPD in any continuous 12" length of weld: 3" 75 mm

INADEQUATE CROSS PENETRATIONMaximum length of an individual indication of ICP: 2 inches or 50mmMaximum length of indications of ICP in any continuous 12" length of weld: 2" 50 mm

INCOMPLETE FUSIONMaximum length of an individual indication of IF: 1 inch or 25mmMaximum length of IF in 8% of weld: N/A since total weld exceeds 12 inchesMaximum length of indications of IF in any continuous 12" length of weld: 1" 25 mm

INCOMPLETE FUSION DUE TO COLD LAPMaximum length of individual indications of IFD: 2 inches or 50mmMaximum length of IFD in 8% of weld: 89.4690 mmMaximum length of indications of IFD in any continuous 12" length of weld: 2" 25 mm

INTERNAL CONCAVITY Any length of IC is acceptable, provided the density of the radiographic image of the internal concavity does not exceed that of the thinnest adjacent parent material. For areas that exceed the density of thethinnest adjacent parent material, the criteria for burn through are applicable.

BURN - THROUGHMaximum dimension of BT's image : unacceptable if it exceeds that of the thinnest adjacent parent metal.Maximum dimension of BT: 1/4" or 6mmMaximum dimension is unacceptable if: it exceeds the thinner of the nonnal wall thickness joined, and the density

of the BT's image exceeds that of the thinnest adjacent parent material.The sum of the max dimensions of separate BBT's whose image density exceeds that of the thinnest adjacent parentmaterial exceeds 1/2 inch or 13mm in any continuous 12" length of weld or the total weld length(whichever is less).

API - 110414" Extra Heavy - 0.500" Wall

Page 1 of 2

Page 105: NDT Code Book Made Easy

API - 110414" Extra Heavy - 0.500" Wall

SLAG INCLUSIONSElongated slag inclusions (ESI)Maximum length of an ESI: 2 inches or 50mmParallel ESI indications (Wagon Tracks) shall be considered a single indication unless the width of either of them exceed1/32" or 0.8mm. In that event they shall be considered separate indications.Maximum length of ESI indications in any continuous 12" length of weld: 2" 50 mmMaximum width of an individual ESI indication: 1/16" or 1.6mmIsolated slag inclusions (ISI)Maximum length of ISI indications in any continuous 12" length of weld: 1/2" 13 mmMaximum width of an ISI indication: 1/8" or 3mmMaximum length of ESI and ISI in 8% of weld: 89.4690 mm

POROSITY Individual or Scattered Porosity.Maximum size of an individual pore: 1/8" or 3mmThe size of an individual pore exceeds 25% of the thinner of the nonimal wall thickness joined.The distribution of scattered porosity exceeds the concentration permitted in Figures 19 or 20.Cluster Porosity (CP)Maximum diameter of the cluster: 1/2 inch or 13mmMaximum length of CP indications in any continuous 12" length of weweld: 1/2" 13 mmMaximum length of an individual pore within a cluster: 1/16 inch or 2mmHollow Bead Porosity (HB)Maximum length of an individual indication of HB: 1/2 inch or 13mmMaximum length of HB indications in any continuous 12" length of weld: 2" 50 mmMaximum length of HB in 8% of weld: 89.4690 mmNOTE: The weld is unacceptable if individual indications of HB, each greater than 1/4 inch or 6mm in length, are seperated by less than 2 inches or 50 mm.

CRACKSNote: Any crack which is not a shallow crater crack or star crack is unacceptable.Maximum length of shallow crater cracks or star cracks: 5/32 inch or 4mm

UNDERCUTTINGUndercutting adjacent to the cover pass (EU) and Undercutting adjacent to the root pass (IU)Maximum length of EU and IU indications (in any combination) in a 12 inch length of weld: 2" 50 mmMaximum length of EU and IU indications: 7.3383" 186.3937 mm (This value is 1/6 th of the total weld length)

ACCUMULATION OF IMPERFECTIONSMaximum length of AI indications in any continuous 12 inch or 300 mm length of weld: 2" 50 mmMaximum length of AI indications of 8% of weld: 89.4690 mm

RADIOGRAPHIC INFOPipe O.D. in inches: 14.00"Amount of Penetrameters required for each shot: 1 penetrameter 1" from the end of film and 1 penny in the center.Total weld length: 44.03 1118.3620 mmCassette size to complete weld in most efficient way: 3.5 x 17" 4.5 x 17"Amount of shots to complete weld with 1" on each side of readable film: 38% of weld: 3.5224" 89.4690 mmHole penetrameters are adjacent to the weld and Wire penetrameters are parallel to the weld.

Page 2 of 2

Page 106: NDT Code Book Made Easy

PENETRAMETER SELECTIONNote: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Wire: 0.025 Esn. Wire: B2 S/S Hole: 30

F/S Wire: 0.020 Esn. Wire: B3 F/S Hole: 25Welds with reinforcement: S/S Wire: 0.025 Esn. Wire: B2 S/S Hole: 30

F/S Wire: 0.020 Esn. Wire: B3 F/S Hole: 25Maximum allowable reinforcement: 0.0625"/per sideMaximum reinforcement with DWE/SWV: 0.125" Total of walls + reinforcement: 2.311" 58.6994 mmMaximum reinforcement with DWE/DWV: 0.125" Total of walls + reinforcement: 2.311" 58.6994 mmMaximum reinforcement with SWE/SWV: 0.0625" Total of wall + reinforcement: 1.1555" 29.3497 mm

INADEQUATE PENETRATION WITHOUT HIGH LOWMaximum length of individual indication of IP : 1 inch or 25mmMaximum length of IP in 8% of weld: N/A since total weld exceeds 12 inchesMaximum length of indications in any continuous 12" length of weld: 1" 25 mm

INADEQUATE PENETRATION DUE TO HIGH LOWMaximum length of individual indication of IPD: 2 inches or 50mmMaximum length of indications of IPD in any continuous 12" length of weld: 3" 75 mm

INADEQUATE CROSS PENETRATIONMaximum length of an individual indication of ICP: 2 inches or 50mmMaximum length of indications of ICP in any continuous 12" length of weld: 2" 50 mm

INCOMPLETE FUSIONMaximum length of an individual indication of IF: 1 inch or 25mmMaximum length of IF in 8% of weld: N/A since total weld exceeds 12 inchesMaximum length of indications of IF in any continuous 12" length of weld: 1" 25 mm

INCOMPLETE FUSION DUE TO COLD LAPMaximum length of individual indications of IFD: 2 inches or 50mmMaximum length of IFD in 8% of weld: 89.4690 mmMaximum length of indications of IFD in any continuous 12" length of weld: 2" 25 mm

INTERNAL CONCAVITY Any length of IC is acceptable, provided the density of the radiographic image of the internal concavity does not exceed that of the thinnest adjacent parent material. For areas that exceed the density of thethinnest adjacent parent material, the criteria for burn through are applicable.

BURN - THROUGHMaximum dimension of BT's image : unacceptable if it exceeds that of the thinnest adjacent parent metal.Maximum dimension of BT: 1/4" or 6mmMaximum dimension is unacceptable if: it exceeds the thinner of the nonnal wall thickness joined, and the density

of the BT's image exceeds that of the thinnest adjacent parent material.The sum of the max dimensions of separate BBT's whose image density exceeds that of the thinnest adjacent parentmaterial exceeds 1/2 inch or 13mm in any continuous 12" length of weld or the total weld length(whichever is less).

API - 110414" s/120 - 1.093" Wall

Page 1 of 2

Page 107: NDT Code Book Made Easy

API - 110414" s/120 - 1.093" Wall

SLAG INCLUSIONSElongated slag inclusions (ESI)Maximum length of an ESI: 2 inches or 50mmParallel ESI indications (Wagon Tracks) shall be considered a single indication unless the width of either of them exceed1/32" or 0.8mm. In that event they shall be considered separate indications.Maximum length of ESI indications in any continuous 12" length of weld: 2" 50 mmMaximum width of an individual ESI indication: 1/16" or 1.6mmIsolated slag inclusions (ISI)Maximum length of ISI indications in any continuous 12" length of weld: 1/2" 13 mmMaximum width of an ISI indication: 1/8" or 3mmMaximum length of ESI and ISI in 8% of weld: 89.4690 mm

POROSITY Individual or Scattered Porosity.Maximum size of an individual pore: 1/8" or 3mmThe size of an individual pore exceeds 25% of the thinner of the nonimal wall thickness joined.The distribution of scattered porosity exceeds the concentration permitted in Figures 19 or 20.Cluster Porosity (CP)Maximum diameter of the cluster: 1/2 inch or 13mmMaximum length of CP indications in any continuous 12" length of weweld: 1/2" 13 mmMaximum length of an individual pore within a cluster: 1/16 inch or 2mmHollow Bead Porosity (HB)Maximum length of an individual indication of HB: 1/2 inch or 13mmMaximum length of HB indications in any continuous 12" length of weld: 2" 50 mmMaximum length of HB in 8% of weld: 89.4690 mmNOTE: The weld is unacceptable if individual indications of HB, each greater than 1/4 inch or 6mm in length, are seperated by less than 2 inches or 50 mm.

CRACKSNote: Any crack which is not a shallow crater crack or star crack is unacceptable.Maximum length of shallow crater cracks or star cracks: 5/32 inch or 4mm

UNDERCUTTINGUndercutting adjacent to the cover pass (EU) and Undercutting adjacent to the root pass (IU)Maximum length of EU and IU indications (in any combination) in a 12 inch length of weld: 2" 50 mmMaximum length of EU and IU indications: 7.3383" 186.3937 mm (This value is 1/6 th of the total weld length)

ACCUMULATION OF IMPERFECTIONSMaximum length of AI indications in any continuous 12 inch or 300 mm length of weld: 2" 50 mmMaximum length of AI indications of 8% of weld: 89.4690 mm

RADIOGRAPHIC INFOPipe O.D. in inches: 14.00"Amount of Penetrameters required for each shot: 1 penetrameter 1" from the end of film and 1 penny in the center.Total weld length: 44.03 1118.3620 mmCassette size to complete weld in most efficient way: 3.5 x 17" 4.5 x 17"Amount of shots to complete weld with 1" on each side of readable film: 48% of weld: 3.5224" 89.4690 mmHole penetrameters are adjacent to the weld and Wire penetrameters are parallel to the weld.

Page 2 of 2

Page 108: NDT Code Book Made Easy

PENETRAMETER SELECTIONNote: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Wire: 0.025 Esn. Wire: B2 S/S Hole: 30

F/S Wire: 0.020 Esn. Wire: B3 F/S Hole: 25Welds with reinforcement: S/S Wire: 0.025 Esn. Wire: B2 S/S Hole: 30

F/S Wire: 0.020 Esn. Wire: B3 F/S Hole: 25Maximum allowable reinforcement: 0.0625"/per sideMaximum reinforcement with DWE/SWV: 0.125" Total of walls + reinforcement: 2.311" 58.6994 mmMaximum reinforcement with DWE/DWV: 0.125" Total of walls + reinforcement: 2.311" 58.6994 mmMaximum reinforcement with SWE/SWV: 0.0625" Total of wall + reinforcement: 1.1555" 29.3497 mm

INADEQUATE PENETRATION WITHOUT HIGH LOWMaximum length of individual indication of IP : 1 inch or 25mmMaximum length of IP in 8% of weld: N/A since total weld exceeds 12 inchesMaximum length of indications in any continuous 12" length of weld: 1" 25 mm

INADEQUATE PENETRATION DUE TO HIGH LOWMaximum length of individual indication of IPD: 2 inches or 50mmMaximum length of indications of IPD in any continuous 12" length of weld: 3" 75 mm

INADEQUATE CROSS PENETRATIONMaximum length of an individual indication of ICP: 2 inches or 50mmMaximum length of indications of ICP in any continuous 12" length of weld: 2" 50 mm

INCOMPLETE FUSIONMaximum length of an individual indication of IF: 1 inch or 25mmMaximum length of IF in 8% of weld: N/A since total weld exceeds 12 inchesMaximum length of indications of IF in any continuous 12" length of weld: 1" 25 mm

INCOMPLETE FUSION DUE TO COLD LAPMaximum length of individual indications of IFD: 2 inches or 50mmMaximum length of IFD in 8% of weld: 89.4690 mmMaximum length of indications of IFD in any continuous 12" length of weld: 2" 25 mm

INTERNAL CONCAVITY Any length of IC is acceptable, provided the density of the radiographic image of the internal concavity does not exceed that of the thinnest adjacent parent material. For areas that exceed the density of thethinnest adjacent parent material, the criteria for burn through are applicable.

BURN - THROUGHMaximum dimension of BT's image : unacceptable if it exceeds that of the thinnest adjacent parent metal.Maximum dimension of BT: 1/4" or 6mmMaximum dimension is unacceptable if: it exceeds the thinner of the nonnal wall thickness joined, and the density

of the BT's image exceeds that of the thinnest adjacent parent material.The sum of the max dimensions of separate BBT's whose image density exceeds that of the thinnest adjacent parentmaterial exceeds 1/2 inch or 13mm in any continuous 12" length of weld or the total weld length(whichever is less).

API - 110414" s/140 - 1.250" Wall

Page 1 of 2

Page 109: NDT Code Book Made Easy

API - 110414" s/140 - 1.250" Wall

SLAG INCLUSIONSElongated slag inclusions (ESI)Maximum length of an ESI: 2 inches or 50mmParallel ESI indications (Wagon Tracks) shall be considered a single indication unless the width of either of them exceed1/32" or 0.8mm. In that event they shall be considered separate indications.Maximum length of ESI indications in any continuous 12" length of weld: 2" 50 mmMaximum width of an individual ESI indication: 1/16" or 1.6mmIsolated slag inclusions (ISI)Maximum length of ISI indications in any continuous 12" length of weld: 1/2" 13 mmMaximum width of an ISI indication: 1/8" or 3mmMaximum length of ESI and ISI in 8% of weld: 89.4690 mm

POROSITY Individual or Scattered Porosity.Maximum size of an individual pore: 1/8" or 3mmThe size of an individual pore exceeds 25% of the thinner of the nonimal wall thickness joined.The distribution of scattered porosity exceeds the concentration permitted in Figures 19 or 20.Cluster Porosity (CP)Maximum diameter of the cluster: 1/2 inch or 13mmMaximum length of CP indications in any continuous 12" length of weweld: 1/2" 13 mmMaximum length of an individual pore within a cluster: 1/16 inch or 2mmHollow Bead Porosity (HB)Maximum length of an individual indication of HB: 1/2 inch or 13mmMaximum length of HB indications in any continuous 12" length of weld: 2" 50 mmMaximum length of HB in 8% of weld: 89.4690 mmNOTE: The weld is unacceptable if individual indications of HB, each greater than 1/4 inch or 6mm in length, are seperated by less than 2 inches or 50 mm.

CRACKSNote: Any crack which is not a shallow crater crack or star crack is unacceptable.Maximum length of shallow crater cracks or star cracks: 5/32 inch or 4mm

UNDERCUTTINGUndercutting adjacent to the cover pass (EU) and Undercutting adjacent to the root pass (IU)Maximum length of EU and IU indications (in any combination) in a 12 inch length of weld: 2" 50 mmMaximum length of EU and IU indications: 7.3383" 186.3937 mm (This value is 1/6 th of the total weld length)

ACCUMULATION OF IMPERFECTIONSMaximum length of AI indications in any continuous 12 inch or 300 mm length of weld: 2" 50 mmMaximum length of AI indications of 8% of weld: 89.4690 mm

RADIOGRAPHIC INFOPipe O.D. in inches: 14.00"Amount of Penetrameters required for each shot: 1 penetrameter 1" from the end of film and 1 penny in the center.Total weld length: 44.03 1118.3620 mmCassette size to complete weld in most efficient way: 3.5 x 17" 4.5 x 17"Amount of shots to complete weld with 1" on each side of readable film: 48% of weld: 3.5224" 89.4690 mmHole penetrameters are adjacent to the weld and Wire penetrameters are parallel to the weld.

Page 2 of 2

Page 110: NDT Code Book Made Easy

PENETRAMETER SELECTIONNote: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Wire: 0.032 Esn. Wire: B1 or C6 S/S Hole: 35

F/S Wire: 0.025 Esn. Wire: B2 F/S Hole: 30Welds with reinforcement: S/S Wire: 0.032 Esn. Wire: B1 or C6 S/S Hole: 35

F/S Wire: 0.025 Esn. Wire: B2 F/S Hole: 30Maximum allowable reinforcement: 0.0625"/per sideMaximum reinforcement with DWE/SWV: 0.125" Total of walls + reinforcement: 2.937" 74.5998 mmMaximum reinforcement with DWE/DWV: 0.125" Total of walls + reinforcement: 2.937" 74.5998 mmMaximum reinforcement with SWE/SWV: 0.0625" Total of wall + reinforcement: 1.4685" 37.2999 mm

INADEQUATE PENETRATION WITHOUT HIGH LOWMaximum length of individual indication of IP : 1 inch or 25mmMaximum length of IP in 8% of weld: N/A since total weld exceeds 12 inchesMaximum length of indications in any continuous 12" length of weld: 1" 25 mm

INADEQUATE PENETRATION DUE TO HIGH LOWMaximum length of individual indication of IPD: 2 inches or 50mmMaximum length of indications of IPD in any continuous 12" length of weld: 3" 75 mm

INADEQUATE CROSS PENETRATIONMaximum length of an individual indication of ICP: 2 inches or 50mmMaximum length of indications of ICP in any continuous 12" length of weld: 2" 50 mm

INCOMPLETE FUSIONMaximum length of an individual indication of IF: 1 inch or 25mmMaximum length of IF in 8% of weld: N/A since total weld exceeds 12 inchesMaximum length of indications of IF in any continuous 12" length of weld: 1" 25 mm

INCOMPLETE FUSION DUE TO COLD LAPMaximum length of individual indications of IFD: 2 inches or 50mmMaximum length of IFD in 8% of weld: 89.4690 mmMaximum length of indications of IFD in any continuous 12" length of weld: 2" 25 mm

INTERNAL CONCAVITY Any length of IC is acceptable, provided the density of the radiographic image of the internal concavity does not exceed that of the thinnest adjacent parent material. For areas that exceed the density of thethinnest adjacent parent material, the criteria for burn through are applicable.

BURN - THROUGHMaximum dimension of BT's image : unacceptable if it exceeds that of the thinnest adjacent parent metal.Maximum dimension of BT: 1/4" or 6mmMaximum dimension is unacceptable if: it exceeds the thinner of the nonnal wall thickness joined, and the density

of the BT's image exceeds that of the thinnest adjacent parent material.The sum of the max dimensions of separate BBT's whose image density exceeds that of the thinnest adjacent parentmaterial exceeds 1/2 inch or 13mm in any continuous 12" length of weld or the total weld length(whichever is less).

API - 110414" s/160 - 1.406" Wall

Page 1 of 2

Page 111: NDT Code Book Made Easy

API - 110414" s/160 - 1.406" Wall

SLAG INCLUSIONSElongated slag inclusions (ESI)Maximum length of an ESI: 2 inches or 50mmParallel ESI indications (Wagon Tracks) shall be considered a single indication unless the width of either of them exceed1/32" or 0.8mm. In that event they shall be considered separate indications.Maximum length of ESI indications in any continuous 12" length of weld: 2" 50 mmMaximum width of an individual ESI indication: 1/16" or 1.6mmIsolated slag inclusions (ISI)Maximum length of ISI indications in any continuous 12" length of weld: 1/2" 13 mmMaximum width of an ISI indication: 1/8" or 3mmMaximum length of ESI and ISI in 8% of weld: 89.4690 mm

POROSITY Individual or Scattered Porosity.Maximum size of an individual pore: 1/8" or 3mmThe size of an individual pore exceeds 25% of the thinner of the nonimal wall thickness joined.The distribution of scattered porosity exceeds the concentration permitted in Figures 19 or 20.Cluster Porosity (CP)Maximum diameter of the cluster: 1/2 inch or 13mmMaximum length of CP indications in any continuous 12" length of weweld: 1/2" 13 mmMaximum length of an individual pore within a cluster: 1/16 inch or 2mmHollow Bead Porosity (HB)Maximum length of an individual indication of HB: 1/2 inch or 13mmMaximum length of HB indications in any continuous 12" length of weld: 2" 50 mmMaximum length of HB in 8% of weld: 89.4690 mmNOTE: The weld is unacceptable if individual indications of HB, each greater than 1/4 inch or 6mm in length, are seperated by less than 2 inches or 50 mm.

CRACKSNote: Any crack which is not a shallow crater crack or star crack is unacceptable.Maximum length of shallow crater cracks or star cracks: 5/32 inch or 4mm

UNDERCUTTINGUndercutting adjacent to the cover pass (EU) and Undercutting adjacent to the root pass (IU)Maximum length of EU and IU indications (in any combination) in a 12 inch length of weld: 2" 50 mmMaximum length of EU and IU indications: 7.3383" 186.3937 mm (This value is 1/6 th of the total weld length)

ACCUMULATION OF IMPERFECTIONSMaximum length of AI indications in any continuous 12 inch or 300 mm length of weld: 2" 50 mmMaximum length of AI indications of 8% of weld: 89.4690 mm

RADIOGRAPHIC INFOPipe O.D. in inches: 14.00"Amount of Penetrameters required for each shot: 1 penetrameter 1" from the end of film and 1 penny in the center.Total weld length: 44.03 1118.3620 mmCassette size to complete weld in most efficient way: 3.5 x 17" 4.5 x 17"Amount of shots to complete weld with 1" on each side of readable film: 58% of weld: 3.5224" 89.4690 mmHole penetrameters are adjacent to the weld and Wire penetrameters are parallel to the weld.

Page 2 of 2

Page 112: NDT Code Book Made Easy

PENETRAMETER SELECTIONNote: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Wire: 0.008 Esn. Wire: A2 S/S Hole: 12

F/S Wire: 0.006 Esn. Wire: A3 F/S Hole: 10Welds with reinforcement: S/S Wire: 0.010 Esn. Wire: A1 or B6 S/S Hole: 15

F/S Wire: 0.008 Esn. Wire: A2 F/S Hole: 12Maximum allowable reinforcement: 0.0625"/per sideMaximum reinforcement with DWE/SWV: 0.125" Total of walls + reinforcement: 0.625" 15.8750 mmMaximum reinforcement with DWE/DWV: 0.125" Total of walls + reinforcement: 0.625" 15.8750 mmMaximum reinforcement with SWE/SWV: 0.0625" Total of wall + reinforcement: 0.3125" 7.9375 mm

INADEQUATE PENETRATION WITHOUT HIGH LOWMaximum length of individual indication of IP : 1 inch or 25mmMaximum length of IP in 8% of weld: N/A since total weld exceeds 12 inchesMaximum length of indications in any continuous 12" length of weld: 1" 25 mm

INADEQUATE PENETRATION DUE TO HIGH LOWMaximum length of individual indication of IPD: 2 inches or 50mmMaximum length of indications of IPD in any continuous 12" length of weld: 3" 75 mm

INADEQUATE CROSS PENETRATIONMaximum length of an individual indication of ICP: 2 inches or 50mmMaximum length of indications of ICP in any continuous 12" length of weld: 2" 50 mm

INCOMPLETE FUSIONMaximum length of an individual indication of IF: 1 inch or 25mmMaximum length of IF in 8% of weld: N/A since total weld exceeds 12 inchesMaximum length of indications of IF in any continuous 12" length of weld: 1" 25 mm

INCOMPLETE FUSION DUE TO COLD LAPMaximum length of individual indications of IFD: 2 inches or 50mmMaximum length of IFD in 8% of weld: 102.2502 mmMaximum length of indications of IFD in any continuous 12" length of weld: 2" 25 mm

INTERNAL CONCAVITY Any length of IC is acceptable, provided the density of the radiographic image of the internal concavity does not exceed that of the thinnest adjacent parent material. For areas that exceed the density of thethinnest adjacent parent material, the criteria for burn through are applicable.

BURN - THROUGHMaximum dimension of BT's image : unacceptable if it exceeds that of the thinnest adjacent parent metal.Maximum dimension of BT: 1/4" or 6mmMaximum dimension is unacceptable if: it exceeds the thinner of the nonnal wall thickness joined, and the density

of the BT's image exceeds that of the thinnest adjacent parent material.The sum of the max dimensions of separate BBT's whose image density exceeds that of the thinnest adjacent parentmaterial exceeds 1/2 inch or 13mm in any continuous 12" length of weld or the total weld length(whichever is less).

API - 110416" s/10 - 0.250" Wall

Page 1 of 2

Page 113: NDT Code Book Made Easy

API - 110416" s/10 - 0.250" Wall

SLAG INCLUSIONSElongated slag inclusions (ESI)Maximum length of an ESI: 2 inches or 50mmParallel ESI indications (Wagon Tracks) shall be considered a single indication unless the width of either of them exceed1/32" or 0.8mm. In that event they shall be considered separate indications.Maximum length of ESI indications in any continuous 12" length of weld: 2" 50 mmMaximum width of an individual ESI indication: 1/16" or 1.6mmIsolated slag inclusions (ISI)Maximum length of ISI indications in any continuous 12" length of weld: 1/2" 13 mmMaximum width of an ISI indication: 1/8" or 3mmMaximum length of ESI and ISI in 8% of weld: 102.2502 mm

POROSITY Individual or Scattered Porosity.Maximum size of an individual pore: 1/8" or 3mmThe size of an individual pore exceeds 25% of the thinner of the nonimal wall thickness joined.The distribution of scattered porosity exceeds the concentration permitted in Figures 19 or 20.Cluster Porosity (CP)Maximum diameter of the cluster: 1/2 inch or 13mmMaximum length of CP indications in any continuous 12" length of weweld: 1/2" 13 mmMaximum length of an individual pore within a cluster: 1/16 inch or 2mmHollow Bead Porosity (HB)Maximum length of an individual indication of HB: 1/2 inch or 13mmMaximum length of HB indications in any continuous 12" length of weld: 2" 50 mmMaximum length of HB in 8% of weld: 102.2502 mmNOTE: The weld is unacceptable if individual indications of HB, each greater than 1/4 inch or 6mm in length, are seperated by less than 2 inches or 50 mm.

CRACKSNote: Any crack which is not a shallow crater crack or star crack is unacceptable.Maximum length of shallow crater cracks or star cracks: 5/32 inch or 4mm

UNDERCUTTINGUndercutting adjacent to the cover pass (EU) and Undercutting adjacent to the root pass (IU)Maximum length of EU and IU indications (in any combination) in a 12 inch length of weld: 2" 50 mmMaximum length of EU and IU indications: 8.387" 213.0298 mm (This value is 1/6 th of the total weld length)

ACCUMULATION OF IMPERFECTIONSMaximum length of AI indications in any continuous 12 inch or 300 mm length of weld: 2" 50 mmMaximum length of AI indications of 8% of weld: 102.2502 mm

RADIOGRAPHIC INFOPipe O.D. in inches: 16Amount of Penetrameters required for each shot: 1 penetrameter 1" from the end of film and 1 penny in the center.Total weld length: 50.32" 1278.1280 mmCassette size to complete weld in most efficient way: 3.5 x 17" 4.5 x 17"Amount of shots to complete weld with 1" on each side of readable film: 48% of weld: 4.0256" 102.2502 mmHole penetrameters are adjacent to the weld and Wire penetrameters are parallel to the weld.

Page 2 of 2

Page 114: NDT Code Book Made Easy

PENETRAMETER SELECTIONNote: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Wire: 0.010 Esn. Wire: A1 or B6 S/S Hole: 15

F/S Wire: 0.008 Esn. Wire: A2 F/S Hole: 12Welds with reinforcement: S/S Wire: 0.013 Esn. Wire: B5 S/S Hole: 17

F/S Wire: 0.010 Esn. Wire: A1 or B6 F/S Hole: 15Maximum allowable reinforcement: 0.0625"/per sideMaximum reinforcement with DWE/SWV: 0.125" Total of walls + reinforcement: 0.875" 22.2250 mmMaximum reinforcement with DWE/DWV: 0.125" Total of walls + reinforcement: 0.875" 22.2250 mmMaximum reinforcement with SWE/SWV: 0.0625" Total of wall + reinforcement: 0.4375" 11.1125 mm

INADEQUATE PENETRATION WITHOUT HIGH LOWMaximum length of individual indication of IP : 1 inch or 25mmMaximum length of IP in 8% of weld: N/A since total weld exceeds 12 inchesMaximum length of indications in any continuous 12" length of weld: 1" 25 mm

INADEQUATE PENETRATION DUE TO HIGH LOWMaximum length of individual indication of IPD: 2 inches or 50mmMaximum length of indications of IPD in any continuous 12" length of weld: 3" 75 mm

INADEQUATE CROSS PENETRATIONMaximum length of an individual indication of ICP: 2 inches or 50mmMaximum length of indications of ICP in any continuous 12" length of weld: 2" 50 mm

INCOMPLETE FUSIONMaximum length of an individual indication of IF: 1 inch or 25mmMaximum length of IF in 8% of weld: N/A since total weld exceeds 12 inchesMaximum length of indications of IF in any continuous 12" length of weld: 1" 25 mm

INCOMPLETE FUSION DUE TO COLD LAPMaximum length of individual indications of IFD: 2 inches or 50mmMaximum length of IFD in 8% of weld: 102.2502 mmMaximum length of indications of IFD in any continuous 12" length of weld: 2" 25 mm

INTERNAL CONCAVITY Any length of IC is acceptable, provided the density of the radiographic image of the internal concavity does not exceed that of the thinnest adjacent parent material. For areas that exceed the density of thethinnest adjacent parent material, the criteria for burn through are applicable.

BURN - THROUGHMaximum dimension of BT's image : unacceptable if it exceeds that of the thinnest adjacent parent metal.Maximum dimension of BT: 1/4" or 6mmMaximum dimension is unacceptable if: it exceeds the thinner of the nonnal wall thickness joined, and the density

of the BT's image exceeds that of the thinnest adjacent parent material.The sum of the max dimensions of separate BBT's whose image density exceeds that of the thinnest adjacent parentmaterial exceeds 1/2 inch or 13mm in any continuous 12" length of weld or the total weld length(whichever is less).

API - 110416" Standard - 0.375" Wall

Page 1 of 2

Page 115: NDT Code Book Made Easy

API - 110416" Standard - 0.375" Wall

SLAG INCLUSIONSElongated slag inclusions (ESI)Maximum length of an ESI: 2 inches or 50mmParallel ESI indications (Wagon Tracks) shall be considered a single indication unless the width of either of them exceed1/32" or 0.8mm. In that event they shall be considered separate indications.Maximum length of ESI indications in any continuous 12" length of weld: 2" 50 mmMaximum width of an individual ESI indication: 1/16" or 1.6mmIsolated slag inclusions (ISI)Maximum length of ISI indications in any continuous 12" length of weld: 1/2" 13 mmMaximum width of an ISI indication: 1/8" or 3mmMaximum length of ESI and ISI in 8% of weld: 102.2502 mm

POROSITY Individual or Scattered Porosity.Maximum size of an individual pore: 1/8" or 3mmThe size of an individual pore exceeds 25% of the thinner of the nonimal wall thickness joined.The distribution of scattered porosity exceeds the concentration permitted in Figures 19 or 20.Cluster Porosity (CP)Maximum diameter of the cluster: 1/2 inch or 13mmMaximum length of CP indications in any continuous 12" length of weweld: 1/2" 13 mmMaximum length of an individual pore within a cluster: 1/16 inch or 2mmHollow Bead Porosity (HB)Maximum length of an individual indication of HB: 1/2 inch or 13mmMaximum length of HB indications in any continuous 12" length of weld: 2" 50 mmMaximum length of HB in 8% of weld: 102.2502 mmNOTE: The weld is unacceptable if individual indications of HB, each greater than 1/4 inch or 6mm in length, are seperated by less than 2 inches or 50 mm.

CRACKSNote: Any crack which is not a shallow crater crack or star crack is unacceptable.Maximum length of shallow crater cracks or star cracks: 5/32 inch or 4mm

UNDERCUTTINGUndercutting adjacent to the cover pass (EU) and Undercutting adjacent to the root pass (IU)Maximum length of EU and IU indications (in any combination) in a 12 inch length of weld: 2" 50 mmMaximum length of EU and IU indications: 8.387" 213.0298 mm (This value is 1/6 th of the total weld length)

ACCUMULATION OF IMPERFECTIONSMaximum length of AI indications in any continuous 12 inch or 300 mm length of weld: 2" 50 mmMaximum length of AI indications of 8% of weld: 102.2502 mm

RADIOGRAPHIC INFOPipe O.D. in inches: 16Amount of Penetrameters required for each shot: 1 penetrameter 1" from the end of film and 1 penny in the center.Total weld length: 50.32" 1278.1280 mmCassette size to complete weld in most efficient way: 3.5 x 17" 4.5 x 17"Amount of shots to complete weld with 1" on each side of readable film: 48% of weld: 4.0256" 102.2502 mmHole penetrameters are adjacent to the weld and Wire penetrameters are parallel to the weld.

Page 2 of 2

Page 116: NDT Code Book Made Easy

PENETRAMETER SELECTIONNote: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Wire: 0.013 Esn. Wire: B5 S/S Hole: 17

F/S Wire: 0.010 Esn. Wire: A1 or B6 F/S Hole: 15Welds with reinforcement: S/S Wire: 0.016 Esn. Wire: B4 S/S Hole: 20

F/S Wire: 0.013 Esn. Wire: B5 F/S Hole: 17Maximum allowable reinforcement: 0.0625"/per sideMaximum reinforcement with DWE/SWV: 0.125" Total of walls + reinforcement: 1.125" 28.5750 mmMaximum reinforcement with DWE/DWV: 0.125" Total of walls + reinforcement: 1.125" 28.5750 mmMaximum reinforcement with SWE/SWV: 0.0625" Total of wall + reinforcement: .5625" 14.2875 mm

INADEQUATE PENETRATION WITHOUT HIGH LOWMaximum length of individual indication of IP : 1 inch or 25mmMaximum length of IP in 8% of weld: N/A since total weld exceeds 12 inchesMaximum length of indications in any continuous 12" length of weld: 1" 25 mm

INADEQUATE PENETRATION DUE TO HIGH LOWMaximum length of individual indication of IPD: 2 inches or 50mmMaximum length of indications of IPD in any continuous 12" length of weld: 3" 75 mm

INADEQUATE CROSS PENETRATIONMaximum length of an individual indication of ICP: 2 inches or 50mmMaximum length of indications of ICP in any continuous 12" length of weld: 2" 50 mm

INCOMPLETE FUSIONMaximum length of an individual indication of IF: 1 inch or 25mmMaximum length of IF in 8% of weld: N/A since total weld exceeds 12 inchesMaximum length of indications of IF in any continuous 12" length of weld: 1" 25 mm

INCOMPLETE FUSION DUE TO COLD LAPMaximum length of individual indications of IFD: 2 inches or 50mmMaximum length of IFD in 8% of weld: 102.2502 mmMaximum length of indications of IFD in any continuous 12" length of weld: 2" 25 mm

INTERNAL CONCAVITY Any length of IC is acceptable, provided the density of the radiographic image of the internal concavity does not exceed that of the thinnest adjacent parent material. For areas that exceed the density of thethinnest adjacent parent material, the criteria for burn through are applicable.

BURN - THROUGHMaximum dimension of BT's image : unacceptable if it exceeds that of the thinnest adjacent parent metal.Maximum dimension of BT: 1/4" or 6mmMaximum dimension is unacceptable if: it exceeds the thinner of the nonnal wall thickness joined, and the density

of the BT's image exceeds that of the thinnest adjacent parent material.The sum of the max dimensions of separate BBT's whose image density exceeds that of the thinnest adjacent parentmaterial exceeds 1/2 inch or 13mm in any continuous 12" length of weld or the total weld length(whichever is less).

API - 110416" s/40 - 0.500" Wall

Page 1 of 2

Page 117: NDT Code Book Made Easy

API - 110416" s/40 - 0.500" Wall

SLAG INCLUSIONSElongated slag inclusions (ESI)Maximum length of an ESI: 2 inches or 50mmParallel ESI indications (Wagon Tracks) shall be considered a single indication unless the width of either of them exceed1/32" or 0.8mm. In that event they shall be considered separate indications.Maximum length of ESI indications in any continuous 12" length of weld: 2" 50 mmMaximum width of an individual ESI indication: 1/16" or 1.6mmIsolated slag inclusions (ISI)Maximum length of ISI indications in any continuous 12" length of weld: 1/2" 13 mmMaximum width of an ISI indication: 1/8" or 3mmMaximum length of ESI and ISI in 8% of weld: 102.2502 mm

POROSITY Individual or Scattered Porosity.Maximum size of an individual pore: 1/8" or 3mmThe size of an individual pore exceeds 25% of the thinner of the nonimal wall thickness joined.The distribution of scattered porosity exceeds the concentration permitted in Figures 19 or 20.Cluster Porosity (CP)Maximum diameter of the cluster: 1/2 inch or 13mmMaximum length of CP indications in any continuous 12" length of weweld: 1/2" 13 mmMaximum length of an individual pore within a cluster: 1/16 inch or 2mmHollow Bead Porosity (HB)Maximum length of an individual indication of HB: 1/2 inch or 13mmMaximum length of HB indications in any continuous 12" length of weld: 2" 50 mmMaximum length of HB in 8% of weld: 102.2502 mmNOTE: The weld is unacceptable if individual indications of HB, each greater than 1/4 inch or 6mm in length, are seperated by less than 2 inches or 50 mm.

CRACKSNote: Any crack which is not a shallow crater crack or star crack is unacceptable.Maximum length of shallow crater cracks or star cracks: 5/32 inch or 4mm

UNDERCUTTINGUndercutting adjacent to the cover pass (EU) and Undercutting adjacent to the root pass (IU)Maximum length of EU and IU indications (in any combination) in a 12 inch length of weld: 2" 50 mmMaximum length of EU and IU indications: 8.387" 213.0298 mm (This value is 1/6 th of the total weld length)

ACCUMULATION OF IMPERFECTIONSMaximum length of AI indications in any continuous 12 inch or 300 mm length of weld: 2" 50 mmMaximum length of AI indications of 8% of weld: 102.2502 mm

RADIOGRAPHIC INFOPipe O.D. in inches: 16Amount of Penetrameters required for each shot: 1 penetrameter 1" from the end of film and 1 penny in the center.Total weld length: 50.32" 1278.1280 mmCassette size to complete weld in most efficient way: 3.5 x 17" 4.5 x 17"Amount of shots to complete weld with 1" on each side of readable film: 48% of weld: 4.0256" 102.2502 mmHole penetrameters are adjacent to the weld and Wire penetrameters are parallel to the weld.

Page 2 of 2

Page 118: NDT Code Book Made Easy

PENETRAMETER SELECTIONNote: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Wire: 0.013 Esn. Wire: B5 S/S Hole: 17

F/S Wire: 0.010 Esn. Wire: A1 or B6 F/S Hole: 15Welds with reinforcement: S/S Wire: 0.016 Esn. Wire: B4 S/S Hole: 20

F/S Wire: 0.013 Esn. Wire: B5 F/S Hole: 17Maximum allowable reinforcement: 0.0625"/per sideMaximum reinforcement with DWE/SWV: 0.125" Total of walls + reinforcement: 1.125" 28.5750 mmMaximum reinforcement with DWE/DWV: 0.125" Total of walls + reinforcement: 1.125" 28.5750 mmMaximum reinforcement with SWE/SWV: 0.0625" Total of wall + reinforcement: .5625" 14.2875 mm

INADEQUATE PENETRATION WITHOUT HIGH LOWMaximum length of individual indication of IP : 1 inch or 25mmMaximum length of IP in 8% of weld: N/A since total weld exceeds 12 inchesMaximum length of indications in any continuous 12" length of weld: 1" 25 mm

INADEQUATE PENETRATION DUE TO HIGH LOWMaximum length of individual indication of IPD: 2 inches or 50mmMaximum length of indications of IPD in any continuous 12" length of weld: 3" 75 mm

INADEQUATE CROSS PENETRATIONMaximum length of an individual indication of ICP: 2 inches or 50mmMaximum length of indications of ICP in any continuous 12" length of weld: 2" 50 mm

INCOMPLETE FUSIONMaximum length of an individual indication of IF: 1 inch or 25mmMaximum length of IF in 8% of weld: N/A since total weld exceeds 12 inchesMaximum length of indications of IF in any continuous 12" length of weld: 1" 25 mm

INCOMPLETE FUSION DUE TO COLD LAPMaximum length of individual indications of IFD: 2 inches or 50mmMaximum length of IFD in 8% of weld: 102.2502 mmMaximum length of indications of IFD in any continuous 12" length of weld: 2" 25 mm

INTERNAL CONCAVITY Any length of IC is acceptable, provided the density of the radiographic image of the internal concavity does not exceed that of the thinnest adjacent parent material. For areas that exceed the density of thethinnest adjacent parent material, the criteria for burn through are applicable.

BURN - THROUGHMaximum dimension of BT's image : unacceptable if it exceeds that of the thinnest adjacent parent metal.Maximum dimension of BT: 1/4" or 6mmMaximum dimension is unacceptable if: it exceeds the thinner of the nonnal wall thickness joined, and the density

of the BT's image exceeds that of the thinnest adjacent parent material.The sum of the max dimensions of separate BBT's whose image density exceeds that of the thinnest adjacent parentmaterial exceeds 1/2 inch or 13mm in any continuous 12" length of weld or the total weld length(whichever is less).

API - 110416" Extra Strong - 0.500" Wall

Page 1 of 2

Page 119: NDT Code Book Made Easy

API - 110416" Extra Strong - 0.500" Wall

SLAG INCLUSIONSElongated slag inclusions (ESI)Maximum length of an ESI: 2 inches or 50mmParallel ESI indications (Wagon Tracks) shall be considered a single indication unless the width of either of them exceed1/32" or 0.8mm. In that event they shall be considered separate indications.Maximum length of ESI indications in any continuous 12" length of weld: 2" 50 mmMaximum width of an individual ESI indication: 1/16" or 1.6mmIsolated slag inclusions (ISI)Maximum length of ISI indications in any continuous 12" length of weld: 1/2" 13 mmMaximum width of an ISI indication: 1/8" or 3mmMaximum length of ESI and ISI in 8% of weld: 102.2502 mm

POROSITY Individual or Scattered Porosity.Maximum size of an individual pore: 1/8" or 3mmThe size of an individual pore exceeds 25% of the thinner of the nonimal wall thickness joined.The distribution of scattered porosity exceeds the concentration permitted in Figures 19 or 20.Cluster Porosity (CP)Maximum diameter of the cluster: 1/2 inch or 13mmMaximum length of CP indications in any continuous 12" length of weweld: 1/2" 13 mmMaximum length of an individual pore within a cluster: 1/16 inch or 2mmHollow Bead Porosity (HB)Maximum length of an individual indication of HB: 1/2 inch or 13mmMaximum length of HB indications in any continuous 12" length of weld: 2" 50 mmMaximum length of HB in 8% of weld: 102.2502 mmNOTE: The weld is unacceptable if individual indications of HB, each greater than 1/4 inch or 6mm in length, are seperated by less than 2 inches or 50 mm.

CRACKSNote: Any crack which is not a shallow crater crack or star crack is unacceptable.Maximum length of shallow crater cracks or star cracks: 5/32 inch or 4mm

UNDERCUTTINGUndercutting adjacent to the cover pass (EU) and Undercutting adjacent to the root pass (IU)Maximum length of EU and IU indications (in any combination) in a 12 inch length of weld: 2" 50 mmMaximum length of EU and IU indications: 8.387" 213.0298 mm (This value is 1/6 th of the total weld length)

ACCUMULATION OF IMPERFECTIONSMaximum length of AI indications in any continuous 12 inch or 300 mm length of weld: 2" 50 mmMaximum length of AI indications of 8% of weld: 102.2502 mm

RADIOGRAPHIC INFOPipe O.D. in inches: 16Amount of Penetrameters required for each shot: 1 penetrameter 1" from the end of film and 1 penny in the center.Total weld length: 50.32" 1278.1280 mmCassette size to complete weld in most efficient way: 3.5 x 17" 4.5 x 17"Amount of shots to complete weld with 1" on each side of readable film: 48% of weld: 4.0256" 102.2502 mmHole penetrameters are adjacent to the weld and Wire penetrameters are parallel to the weld.

Page 2 of 2

Page 120: NDT Code Book Made Easy

PENETRAMETER SELECTIONNote: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Wire: 0.020 Esn. Wire: B3 S/S Hole: 25

F/S Wire: 0.016 Esn. Wire: B4 F/S Hole: 20Welds with reinforcement: S/S Wire: 0.020 Esn. Wire: B3 S/S Hole: 25

F/S Wire: 0.016 Esn. Wire: B4 F/S Hole: 20Maximum allowable reinforcement: 0.0625"/per sideMaximum reinforcement with DWE/SWV: 0.125" Total of walls + reinforcement: 1.813" 46.0502 mmMaximum reinforcement with DWE/DWV: 0.125" Total of walls + reinforcement: 1.813" 46.0502 mmMaximum reinforcement with SWE/SWV: 0.0625" Total of wall + reinforcement: .9065" 23.0251 mm

INADEQUATE PENETRATION WITHOUT HIGH LOWMaximum length of individual indication of IP : 1 inch or 25mmMaximum length of IP in 8% of weld: N/A since total weld exceeds 12 inchesMaximum length of indications in any continuous 12" length of weld: 1" 25 mm

INADEQUATE PENETRATION DUE TO HIGH LOWMaximum length of individual indication of IPD: 2 inches or 50mmMaximum length of indications of IPD in any continuous 12" length of weld: 3" 75 mm

INADEQUATE CROSS PENETRATIONMaximum length of an individual indication of ICP: 2 inches or 50mmMaximum length of indications of ICP in any continuous 12" length of weld: 2" 50 mm

INCOMPLETE FUSIONMaximum length of an individual indication of IF: 1 inch or 25mmMaximum length of IF in 8% of weld: N/A since total weld exceeds 12 inchesMaximum length of indications of IF in any continuous 12" length of weld: 1" 25 mm

INCOMPLETE FUSION DUE TO COLD LAPMaximum length of individual indications of IFD: 2 inches or 50mmMaximum length of IFD in 8% of weld: 102.2502 mmMaximum length of indications of IFD in any continuous 12" length of weld: 2" 25 mm

INTERNAL CONCAVITY Any length of IC is acceptable, provided the density of the radiographic image of the internal concavity does not exceed that of the thinnest adjacent parent material. For areas that exceed the density of thethinnest adjacent parent material, the criteria for burn through are applicable.

BURN - THROUGHMaximum dimension of BT's image : unacceptable if it exceeds that of the thinnest adjacent parent metal.Maximum dimension of BT: 1/4" or 6mmMaximum dimension is unacceptable if: it exceeds the thinner of the nonnal wall thickness joined, and the density

of the BT's image exceeds that of the thinnest adjacent parent material.The sum of the max dimensions of separate BBT's whose image density exceeds that of the thinnest adjacent parentmaterial exceeds 1/2 inch or 13mm in any continuous 12" length of weld or the total weld length(whichever is less).

API - 110416" s/80 - 0.844" Wall

Page 1 of 2

Page 121: NDT Code Book Made Easy

API - 110416" s/80 - 0.844" Wall

SLAG INCLUSIONSElongated slag inclusions (ESI)Maximum length of an ESI: 2 inches or 50mmParallel ESI indications (Wagon Tracks) shall be considered a single indication unless the width of either of them exceed1/32" or 0.8mm. In that event they shall be considered separate indications.Maximum length of ESI indications in any continuous 12" length of weld: 2" 50 mmMaximum width of an individual ESI indication: 1/16" or 1.6mmIsolated slag inclusions (ISI)Maximum length of ISI indications in any continuous 12" length of weld: 1/2" 13 mmMaximum width of an ISI indication: 1/8" or 3mmMaximum length of ESI and ISI in 8% of weld: 102.2502 mm

POROSITY Individual or Scattered Porosity.Maximum size of an individual pore: 1/8" or 3mmThe size of an individual pore exceeds 25% of the thinner of the nonimal wall thickness joined.The distribution of scattered porosity exceeds the concentration permitted in Figures 19 or 20.Cluster Porosity (CP)Maximum diameter of the cluster: 1/2 inch or 13mmMaximum length of CP indications in any continuous 12" length of weweld: 1/2" 13 mmMaximum length of an individual pore within a cluster: 1/16 inch or 2mmHollow Bead Porosity (HB)Maximum length of an individual indication of HB: 1/2 inch or 13mmMaximum length of HB indications in any continuous 12" length of weld: 2" 50 mmMaximum length of HB in 8% of weld: 102.2502 mmNOTE: The weld is unacceptable if individual indications of HB, each greater than 1/4 inch or 6mm in length, are seperated by less than 2 inches or 50 mm.

CRACKSNote: Any crack which is not a shallow crater crack or star crack is unacceptable.Maximum length of shallow crater cracks or star cracks: 5/32 inch or 4mm

UNDERCUTTINGUndercutting adjacent to the cover pass (EU) and Undercutting adjacent to the root pass (IU)Maximum length of EU and IU indications (in any combination) in a 12 inch length of weld: 2" 50 mmMaximum length of EU and IU indications: 8.387" 213.0298 mm (This value is 1/6 th of the total weld length)

ACCUMULATION OF IMPERFECTIONSMaximum length of AI indications in any continuous 12 inch or 300 mm length of weld: 2" 50 mmMaximum length of AI indications of 8% of weld: 102.2502 mm

RADIOGRAPHIC INFOPipe O.D. in inches: 16Amount of Penetrameters required for each shot: 1 penetrameter 1" from the end of film and 1 penny in the center.Total weld length: 50.32" 1278.1280 mmCassette size to complete weld in most efficient way: 3.5 x 17" 4.5 x 17"Amount of shots to complete weld with 1" on each side of readable film: 48% of weld: 4.0256" 102.2502 mmHole penetrameters are adjacent to the weld and Wire penetrameters are parallel to the weld.

Page 2 of 2

Page 122: NDT Code Book Made Easy

PENETRAMETER SELECTIONNote: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Wire: 0.025 Esn. Wire: B2 S/S Hole: 30

F/S Wire: 0.020 Esn. Wire: B3 F/S Hole: 25Welds with reinforcement: S/S Wire: 0.025 Esn. Wire: B2 S/S Hole: 30

F/S Wire: 0.020 Esn. Wire: B3 F/S Hole: 25Maximum allowable reinforcement: 0.0625"/per sideMaximum reinforcement with DWE/SWV: 0.125" Total of walls + reinforcement: 2.563" 65.1002 mmMaximum reinforcement with DWE/DWV: 0.125" Total of walls + reinforcement: 2.563" 65.1002 mmMaximum reinforcement with SWE/SWV: 0.0625" Total of wall + reinforcement: 1.2815" 32.5501 mm

INADEQUATE PENETRATION WITHOUT HIGH LOWMaximum length of individual indication of IP : 1 inch or 25mmMaximum length of IP in 8% of weld: N/A since total weld exceeds 12 inchesMaximum length of indications in any continuous 12" length of weld: 1" 25 mm

INADEQUATE PENETRATION DUE TO HIGH LOWMaximum length of individual indication of IPD: 2 inches or 50mmMaximum length of indications of IPD in any continuous 12" length of weld: 3" 75 mm

INADEQUATE CROSS PENETRATIONMaximum length of an individual indication of ICP: 2 inches or 50mmMaximum length of indications of ICP in any continuous 12" length of weld: 2" 50 mm

INCOMPLETE FUSIONMaximum length of an individual indication of IF: 1 inch or 25mmMaximum length of IF in 8% of weld: N/A since total weld exceeds 12 inchesMaximum length of indications of IF in any continuous 12" length of weld: 1" 25 mm

INCOMPLETE FUSION DUE TO COLD LAPMaximum length of individual indications of IFD: 2 inches or 50mmMaximum length of IFD in 8% of weld: 102.2502 mmMaximum length of indications of IFD in any continuous 12" length of weld: 2" 25 mm

INTERNAL CONCAVITY Any length of IC is acceptable, provided the density of the radiographic image of the internal concavity does not exceed that of the thinnest adjacent parent material. For areas that exceed the density of thethinnest adjacent parent material, the criteria for burn through are applicable.

BURN - THROUGHMaximum dimension of BT's image : unacceptable if it exceeds that of the thinnest adjacent parent metal.Maximum dimension of BT: 1/4" or 6mmMaximum dimension is unacceptable if: it exceeds the thinner of the nonnal wall thickness joined, and the density

of the BT's image exceeds that of the thinnest adjacent parent material.The sum of the max dimensions of separate BBT's whose image density exceeds that of the thinnest adjacent parentmaterial exceeds 1/2 inch or 13mm in any continuous 12" length of weld or the total weld length(whichever is less).

API - 110416" s/120 - 1.219" Wall

Page 1 of 2

Page 123: NDT Code Book Made Easy

API - 110416" s/120 - 1.219" Wall

SLAG INCLUSIONSElongated slag inclusions (ESI)Maximum length of an ESI: 2 inches or 50mmParallel ESI indications (Wagon Tracks) shall be considered a single indication unless the width of either of them exceed1/32" or 0.8mm. In that event they shall be considered separate indications.Maximum length of ESI indications in any continuous 12" length of weld: 2" 50 mmMaximum width of an individual ESI indication: 1/16" or 1.6mmIsolated slag inclusions (ISI)Maximum length of ISI indications in any continuous 12" length of weld: 1/2" 13 mmMaximum width of an ISI indication: 1/8" or 3mmMaximum length of ESI and ISI in 8% of weld: 102.2502 mm

POROSITY Individual or Scattered Porosity.Maximum size of an individual pore: 1/8" or 3mmThe size of an individual pore exceeds 25% of the thinner of the nonimal wall thickness joined.The distribution of scattered porosity exceeds the concentration permitted in Figures 19 or 20.Cluster Porosity (CP)Maximum diameter of the cluster: 1/2 inch or 13mmMaximum length of CP indications in any continuous 12" length of weweld: 1/2" 13 mmMaximum length of an individual pore within a cluster: 1/16 inch or 2mmHollow Bead Porosity (HB)Maximum length of an individual indication of HB: 1/2 inch or 13mmMaximum length of HB indications in any continuous 12" length of weld: 2" 50 mmMaximum length of HB in 8% of weld: 102.2502 mmNOTE: The weld is unacceptable if individual indications of HB, each greater than 1/4 inch or 6mm in length, are seperated by less than 2 inches or 50 mm.

CRACKSNote: Any crack which is not a shallow crater crack or star crack is unacceptable.Maximum length of shallow crater cracks or star cracks: 5/32 inch or 4mm

UNDERCUTTINGUndercutting adjacent to the cover pass (EU) and Undercutting adjacent to the root pass (IU)Maximum length of EU and IU indications (in any combination) in a 12 inch length of weld: 2" 50 mmMaximum length of EU and IU indications: 8.387" 213.0298 mm (This value is 1/6 th of the total weld length)

ACCUMULATION OF IMPERFECTIONSMaximum length of AI indications in any continuous 12 inch or 300 mm length of weld: 2" 50 mmMaximum length of AI indications of 8% of weld: 102.2502 mm

RADIOGRAPHIC INFOPipe O.D. in inches: 16Amount of Penetrameters required for each shot: 1 penetrameter 1" from the end of film and 1 penny in the center.Total weld length: 50.32" 1278.1280 mmCassette size to complete weld in most efficient way: 3.5 x 17" 4.5 x 17"Amount of shots to complete weld with 1" on each side of readable film: 58% of weld: 4.0256" 102.2502 mmHole penetrameters are adjacent to the weld and Wire penetrameters are parallel to the weld.

Page 2 of 2

Page 124: NDT Code Book Made Easy

PENETRAMETER SELECTIONNote: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Wire: 0.032 Esn. Wire: B1 or C6 S/S Hole: 35

F/S Wire: 0.025 Esn. Wire: B2 F/S Hole: 30Welds with reinforcement: S/S Wire: 0.032 Esn. Wire: B1 or C6 S/S Hole: 35

F/S Wire: 0.025 Esn. Wire: B2 F/S Hole: 30Maximum allowable reinforcement: 0.0625"/per sideMaximum reinforcement with DWE/SWV: 0.125" Total of walls + reinforcement: 2.999" 76.1746 mmMaximum reinforcement with DWE/DWV: 0.125" Total of walls + reinforcement: 2.999" 76.1746 mmMaximum reinforcement with SWE/SWV: 0.0625" Total of wall + reinforcement: 1.4995" 38.0873 mm

INADEQUATE PENETRATION WITHOUT HIGH LOWMaximum length of individual indication of IP : 1 inch or 25mmMaximum length of IP in 8% of weld: N/A since total weld exceeds 12 inchesMaximum length of indications in any continuous 12" length of weld: 1" 25 mm

INADEQUATE PENETRATION DUE TO HIGH LOWMaximum length of individual indication of IPD: 2 inches or 50mmMaximum length of indications of IPD in any continuous 12" length of weld: 3" 75 mm

INADEQUATE CROSS PENETRATIONMaximum length of an individual indication of ICP: 2 inches or 50mmMaximum length of indications of ICP in any continuous 12" length of weld: 2" 50 mm

INCOMPLETE FUSIONMaximum length of an individual indication of IF: 1 inch or 25mmMaximum length of IF in 8% of weld: N/A since total weld exceeds 12 inchesMaximum length of indications of IF in any continuous 12" length of weld: 1" 25 mm

INCOMPLETE FUSION DUE TO COLD LAPMaximum length of individual indications of IFD: 2 inches or 50mmMaximum length of IFD in 8% of weld: 102.2502 mmMaximum length of indications of IFD in any continuous 12" length of weld: 2" 25 mm

INTERNAL CONCAVITY Any length of IC is acceptable, provided the density of the radiographic image of the internal concavity does not exceed that of the thinnest adjacent parent material. For areas that exceed the density of thethinnest adjacent parent material, the criteria for burn through are applicable.

BURN - THROUGHMaximum dimension of BT's image : unacceptable if it exceeds that of the thinnest adjacent parent metal.Maximum dimension of BT: 1/4" or 6mmMaximum dimension is unacceptable if: it exceeds the thinner of the nonnal wall thickness joined, and the density

of the BT's image exceeds that of the thinnest adjacent parent material.The sum of the max dimensions of separate BBT's whose image density exceeds that of the thinnest adjacent parentmaterial exceeds 1/2 inch or 13mm in any continuous 12" length of weld or the total weld length(whichever is less).

API - 110416" s/140 - 1.437" Wall

Page 1 of 2

Page 125: NDT Code Book Made Easy

API - 110416" s/140 - 1.437" Wall

SLAG INCLUSIONSElongated slag inclusions (ESI)Maximum length of an ESI: 2 inches or 50mmParallel ESI indications (Wagon Tracks) shall be considered a single indication unless the width of either of them exceed1/32" or 0.8mm. In that event they shall be considered separate indications.Maximum length of ESI indications in any continuous 12" length of weld: 2" 50 mmMaximum width of an individual ESI indication: 1/16" or 1.6mmIsolated slag inclusions (ISI)Maximum length of ISI indications in any continuous 12" length of weld: 1/2" 13 mmMaximum width of an ISI indication: 1/8" or 3mmMaximum length of ESI and ISI in 8% of weld: 102.2502 mm

POROSITY Individual or Scattered Porosity.Maximum size of an individual pore: 1/8" or 3mmThe size of an individual pore exceeds 25% of the thinner of the nonimal wall thickness joined.The distribution of scattered porosity exceeds the concentration permitted in Figures 19 or 20.Cluster Porosity (CP)Maximum diameter of the cluster: 1/2 inch or 13mmMaximum length of CP indications in any continuous 12" length of weweld: 1/2" 13 mmMaximum length of an individual pore within a cluster: 1/16 inch or 2mmHollow Bead Porosity (HB)Maximum length of an individual indication of HB: 1/2 inch or 13mmMaximum length of HB indications in any continuous 12" length of weld: 2" 50 mmMaximum length of HB in 8% of weld: 102.2502 mmNOTE: The weld is unacceptable if individual indications of HB, each greater than 1/4 inch or 6mm in length, are seperated by less than 2 inches or 50 mm.

CRACKSNote: Any crack which is not a shallow crater crack or star crack is unacceptable.Maximum length of shallow crater cracks or star cracks: 5/32 inch or 4mm

UNDERCUTTINGUndercutting adjacent to the cover pass (EU) and Undercutting adjacent to the root pass (IU)Maximum length of EU and IU indications (in any combination) in a 12 inch length of weld: 2" 50 mmMaximum length of EU and IU indications: 8.387" 213.0298 mm (This value is 1/6 th of the total weld length)

ACCUMULATION OF IMPERFECTIONSMaximum length of AI indications in any continuous 12 inch or 300 mm length of weld: 2" 50 mmMaximum length of AI indications of 8% of weld: 102.2502 mm

RADIOGRAPHIC INFOPipe O.D. in inches: 16Amount of Penetrameters required for each shot: 1 penetrameter 1" from the end of film and 1 penny in the center.Total weld length: 50.32" 1278.1280 mmCassette size to complete weld in most efficient way: 3.5 x 17" 4.5 x 17"Amount of shots to complete weld with 1" on each side of readable film: 58% of weld: 4.0256" 102.2502 mmHole penetrameters are adjacent to the weld and Wire penetrameters are parallel to the weld.

Page 2 of 2

Page 126: NDT Code Book Made Easy

PENETRAMETER SELECTIONNote: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Wire: 0.032 Esn. Wire: B1 or C6 S/S Hole: 35

F/S Wire: 0.025 Esn. Wire: B2 F/S Hole: 30Welds with reinforcement: S/S Wire: 0.032 Esn. Wire: B1 or C6 S/S Hole: 35

F/S Wire: 0.025 Esn. Wire: B2 F/S Hole: 30Maximum allowable reinforcement: 0.0625"/per sideMaximum reinforcement with DWE/SWV: 0.125" Total of walls + reinforcement: 3.313" 84.1502 mmMaximum reinforcement with DWE/DWV: 0.125" Total of walls + reinforcement: 3.313" 84.1502 mmMaximum reinforcement with SWE/SWV: 0.0625" Total of wall + reinforcement: 1.6565" 42.0751 mm

INADEQUATE PENETRATION WITHOUT HIGH LOWMaximum length of individual indication of IP : 1 inch or 25mmMaximum length of IP in 8% of weld: N/A since total weld exceeds 12 inchesMaximum length of indications in any continuous 12" length of weld: 1" 25 mm

INADEQUATE PENETRATION DUE TO HIGH LOWMaximum length of individual indication of IPD: 2 inches or 50mmMaximum length of indications of IPD in any continuous 12" length of weld: 3" 75 mm

INADEQUATE CROSS PENETRATIONMaximum length of an individual indication of ICP: 2 inches or 50mmMaximum length of indications of ICP in any continuous 12" length of weld: 2" 50 mm

INCOMPLETE FUSIONMaximum length of an individual indication of IF: 1 inch or 25mmMaximum length of IF in 8% of weld: N/A since total weld exceeds 12 inchesMaximum length of indications of IF in any continuous 12" length of weld: 1" 25 mm

INCOMPLETE FUSION DUE TO COLD LAPMaximum length of individual indications of IFD: 2 inches or 50mmMaximum length of IFD in 8% of weld: 102.2502 mmMaximum length of indications of IFD in any continuous 12" length of weld: 2" 25 mm

INTERNAL CONCAVITY Any length of IC is acceptable, provided the density of the radiographic image of the internal concavity does not exceed that of the thinnest adjacent parent material. For areas that exceed the density of thethinnest adjacent parent material, the criteria for burn through are applicable.

BURN - THROUGHMaximum dimension of BT's image : unacceptable if it exceeds that of the thinnest adjacent parent metal.Maximum dimension of BT: 1/4" or 6mmMaximum dimension is unacceptable if: it exceeds the thinner of the nonnal wall thickness joined, and the density

of the BT's image exceeds that of the thinnest adjacent parent material.The sum of the max dimensions of separate BBT's whose image density exceeds that of the thinnest adjacent parentmaterial exceeds 1/2 inch or 13mm in any continuous 12" length of weld or the total weld length(whichever is less).

API - 110416" s/160 - 1.594" Wall

Page 1 of 2

Page 127: NDT Code Book Made Easy

API - 110416" s/160 - 1.594" Wall

SLAG INCLUSIONSElongated slag inclusions (ESI)Maximum length of an ESI: 2 inches or 50mmParallel ESI indications (Wagon Tracks) shall be considered a single indication unless the width of either of them exceed1/32" or 0.8mm. In that event they shall be considered separate indications.Maximum length of ESI indications in any continuous 12" length of weld: 2" 50 mmMaximum width of an individual ESI indication: 1/16" or 1.6mmIsolated slag inclusions (ISI)Maximum length of ISI indications in any continuous 12" length of weld: 1/2" 13 mmMaximum width of an ISI indication: 1/8" or 3mmMaximum length of ESI and ISI in 8% of weld: 102.2502 mm

POROSITY Individual or Scattered Porosity.Maximum size of an individual pore: 1/8" or 3mmThe size of an individual pore exceeds 25% of the thinner of the nonimal wall thickness joined.The distribution of scattered porosity exceeds the concentration permitted in Figures 19 or 20.Cluster Porosity (CP)Maximum diameter of the cluster: 1/2 inch or 13mmMaximum length of CP indications in any continuous 12" length of weweld: 1/2" 13 mmMaximum length of an individual pore within a cluster: 1/16 inch or 2mmHollow Bead Porosity (HB)Maximum length of an individual indication of HB: 1/2 inch or 13mmMaximum length of HB indications in any continuous 12" length of weld: 2" 50 mmMaximum length of HB in 8% of weld: 102.2502 mmNOTE: The weld is unacceptable if individual indications of HB, each greater than 1/4 inch or 6mm in length, are seperated by less than 2 inches or 50 mm.

CRACKSNote: Any crack which is not a shallow crater crack or star crack is unacceptable.Maximum length of shallow crater cracks or star cracks: 5/32 inch or 4mm

UNDERCUTTINGUndercutting adjacent to the cover pass (EU) and Undercutting adjacent to the root pass (IU)Maximum length of EU and IU indications (in any combination) in a 12 inch length of weld: 2" 50 mmMaximum length of EU and IU indications: 8.387" 213.0298 mm (This value is 1/6 th of the total weld length)

ACCUMULATION OF IMPERFECTIONSMaximum length of AI indications in any continuous 12 inch or 300 mm length of weld: 2" 50 mmMaximum length of AI indications of 8% of weld: 102.2502 mm

RADIOGRAPHIC INFOPipe O.D. in inches: 16Amount of Penetrameters required for each shot: 1 penetrameter 1" from the end of film and 1 penny in the center.Total weld length: 50.32" 1278.1280 mmCassette size to complete weld in most efficient way: 3.5 x 17" 4.5 x 17"Amount of shots to complete weld with 1" on each side of readable film: 68% of weld: 4.0256" 102.2502 mmHole penetrameters are adjacent to the weld and Wire penetrameters are parallel to the weld.

Page 2 of 2

Page 128: NDT Code Book Made Easy

PENETRAMETER SELECTIONNote: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Wire: 0.008 Esn. Wire: A2 S/S Hole: 12

F/S Wire: 0.006 Esn. Wire: A3 F/S Hole: 10Welds with reinforcement: S/S Wire: 0.010 Esn. Wire: A1 or B6 S/S Hole: 15

F/S Wire: 0.008 Esn. Wire: A2 F/S Hole: 12Maximum allowable reinforcement: 0.0625"/per sideMaximum reinforcement with DWE/SWV: 0.125" Total of walls + reinforcement: 0.625" 15.8750 mmMaximum reinforcement with DWE/DWV: 0.125" Total of walls + reinforcement: 0.625" 15.8750 mmMaximum reinforcement with SWE/SWV: 0.0625" Total of wall + reinforcement: 0.3125" 7.9375 mm

INADEQUATE PENETRATION WITHOUT HIGH LOWMaximum length of individual indication of IP : 1 inch or 25mmMaximum length of IP in 8% of weld: N/A since total weld exceeds 12 inchesMaximum length of indications in any continuous 12" length of weld: 1" 25 mm

INADEQUATE PENETRATION DUE TO HIGH LOWMaximum length of individual indication of IPD: 2 inches or 50mmMaximum length of indications of IPD in any continuous 12" length of weld: 3" 75 mm

INADEQUATE CROSS PENETRATIONMaximum length of an individual indication of ICP: 2 inches or 50mmMaximum length of indications of ICP in any continuous 12" length of weld: 2" 50 mm

INCOMPLETE FUSIONMaximum length of an individual indication of IF: 1 inch or 25mmMaximum length of IF in 8% of weld: N/A since total weld exceeds 12 inchesMaximum length of indications of IF in any continuous 12" length of weld: 1" 25 mm

INCOMPLETE FUSION DUE TO COLD LAPMaximum length of individual indications of IFD: 2 inches or 50mmMaximum length of IFD in 8% of weld: 115.0315 mmMaximum length of indications of IFD in any continuous 12" length of weld: 2" 25 mm

INTERNAL CONCAVITY Any length of IC is acceptable, provided the density of the radiographic image of the internal concavity does not exceed that of the thinnest adjacent parent material. For areas that exceed the density of thethinnest adjacent parent material, the criteria for burn through are applicable.

BURN - THROUGHMaximum dimension of BT's image : unacceptable if it exceeds that of the thinnest adjacent parent metal.Maximum dimension of BT: 1/4" or 6mmMaximum dimension is unacceptable if: it exceeds the thinner of the nonnal wall thickness joined, and the density

of the BT's image exceeds that of the thinnest adjacent parent material.The sum of the max dimensions of separate BBT's whose image density exceeds that of the thinnest adjacent parentmaterial exceeds 1/2 inch or 13mm in any continuous 12" length of weld or the total weld length(whichever is less).

API - 110418" s/10 - 0.250" Wall

Page 1 of 2

Page 129: NDT Code Book Made Easy

API - 110418" s/10 - 0.250" Wall

SLAG INCLUSIONSElongated slag inclusions (ESI)Maximum length of an ESI: 2 inches or 50mmParallel ESI indications (Wagon Tracks) shall be considered a single indication unless the width of either of them exceed1/32" or 0.8mm. In that event they shall be considered separate indications.Maximum length of ESI indications in any continuous 12" length of weld: 2" 50 mmMaximum width of an individual ESI indication: 1/16" or 1.6mmIsolated slag inclusions (ISI)Maximum length of ISI indications in any continuous 12" length of weld: 1/2" 13 mmMaximum width of an ISI indication: 1/8" or 3mmMaximum length of ESI and ISI in 8% of weld: 115.0315 mm

POROSITY Individual or Scattered Porosity.Maximum size of an individual pore: 1/8" or 3mmThe size of an individual pore exceeds 25% of the thinner of the nonimal wall thickness joined.The distribution of scattered porosity exceeds the concentration permitted in Figures 19 or 20.Cluster Porosity (CP)Maximum diameter of the cluster: 1/2 inch or 13mmMaximum length of CP indications in any continuous 12" length of weweld: 1/2" 13 mmMaximum length of an individual pore within a cluster: 1/16 inch or 2mmHollow Bead Porosity (HB)Maximum length of an individual indication of HB: 1/2 inch or 13mmMaximum length of HB indications in any continuous 12" length of weld: 2" 50 mmMaximum length of HB in 8% of weld: 115.0315 mmNOTE: The weld is unacceptable if individual indications of HB, each greater than 1/4 inch or 6mm in length, are seperated by less than 2 inches or 50 mm.

CRACKSNote: Any crack which is not a shallow crater crack or star crack is unacceptable.Maximum length of shallow crater cracks or star cracks: 5/32 inch or 4mm

UNDERCUTTINGUndercutting adjacent to the cover pass (EU) and Undercutting adjacent to the root pass (IU)Maximum length of EU and IU indications (in any combination) in a 12 inch length of weld: 2" 50 mmMaximum length of EU and IU indications: 9.435" 239.6490 mm (This value is 1/6 th of the total weld length)

ACCUMULATION OF IMPERFECTIONSMaximum length of AI indications in any continuous 12 inch or 300 mm length of weld: 2" 50 mmMaximum length of AI indications of 8% of weld: 115.0315 mm

RADIOGRAPHIC INFOPipe O.D. in inches: 18.00"Amount of Penetrameters required for each shot: 1 penetrameter 1" from the end of film and 1 penny in the center.Total weld length: 56.61" 1437.8940 mmCassette size to complete weld in most efficient way: 3.5 x 17" 4.5 x 17"Amount of shots to complete weld with 1" on each side of readable film: 48% of weld: 4.5288" 115.0315 mmHole penetrameters are adjacent to the weld and Wire penetrameters are parallel to the weld.

Page 2 of 2

Page 130: NDT Code Book Made Easy

PENETRAMETER SELECTIONNote: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Wire: 0.010 Esn. Wire: A1 or B6 S/S Hole: 15

F/S Wire: 0.008 Esn. Wire: A2 F/S Hole: 12Welds with reinforcement: S/S Wire: 0.013 Esn. Wire: B5 S/S Hole: 17

F/S Wire: 0.010 Esn. Wire: A1 or B6 F/S Hole: 15Maximum allowable reinforcement: 0.0625"/per sideMaximum reinforcement with DWE/SWV: 0.125" Total of walls + reinforcement: 0.875" 22.2250 mmMaximum reinforcement with DWE/DWV: 0.125" Total of walls + reinforcement: 0.875" 22.2250 mmMaximum reinforcement with SWE/SWV: 0.0625" Total of wall + reinforcement: 0.4375" 11.1125 mm

INADEQUATE PENETRATION WITHOUT HIGH LOWMaximum length of individual indication of IP : 1 inch or 25mmMaximum length of IP in 8% of weld: N/A since total weld exceeds 12 inchesMaximum length of indications in any continuous 12" length of weld: 1" 25 mm

INADEQUATE PENETRATION DUE TO HIGH LOWMaximum length of individual indication of IPD: 2 inches or 50mmMaximum length of indications of IPD in any continuous 12" length of weld: 3" 75 mm

INADEQUATE CROSS PENETRATIONMaximum length of an individual indication of ICP: 2 inches or 50mmMaximum length of indications of ICP in any continuous 12" length of weld: 2" 50 mm

INCOMPLETE FUSIONMaximum length of an individual indication of IF: 1 inch or 25mmMaximum length of IF in 8% of weld: N/A since total weld exceeds 12 inchesMaximum length of indications of IF in any continuous 12" length of weld: 1" 25 mm

INCOMPLETE FUSION DUE TO COLD LAPMaximum length of individual indications of IFD: 2 inches or 50mmMaximum length of IFD in 8% of weld: 115.0315 mmMaximum length of indications of IFD in any continuous 12" length of weld: 2" 25 mm

INTERNAL CONCAVITY Any length of IC is acceptable, provided the density of the radiographic image of the internal concavity does not exceed that of the thinnest adjacent parent material. For areas that exceed the density of thethinnest adjacent parent material, the criteria for burn through are applicable.

BURN - THROUGHMaximum dimension of BT's image : unacceptable if it exceeds that of the thinnest adjacent parent metal.Maximum dimension of BT: 1/4" or 6mmMaximum dimension is unacceptable if: it exceeds the thinner of the nonnal wall thickness joined, and the density

of the BT's image exceeds that of the thinnest adjacent parent material.The sum of the max dimensions of separate BBT's whose image density exceeds that of the thinnest adjacent parentmaterial exceeds 1/2 inch or 13mm in any continuous 12" length of weld or the total weld length(whichever is less).

API - 110418" Standard - 0.375" Wall

Page 1 of 2

Page 131: NDT Code Book Made Easy

API - 110418" Standard - 0.375" Wall

SLAG INCLUSIONSElongated slag inclusions (ESI)Maximum length of an ESI: 2 inches or 50mmParallel ESI indications (Wagon Tracks) shall be considered a single indication unless the width of either of them exceed1/32" or 0.8mm. In that event they shall be considered separate indications.Maximum length of ESI indications in any continuous 12" length of weld: 2" 50 mmMaximum width of an individual ESI indication: 1/16" or 1.6mmIsolated slag inclusions (ISI)Maximum length of ISI indications in any continuous 12" length of weld: 1/2" 13 mmMaximum width of an ISI indication: 1/8" or 3mmMaximum length of ESI and ISI in 8% of weld: 115.0315 mm

POROSITY Individual or Scattered Porosity.Maximum size of an individual pore: 1/8" or 3mmThe size of an individual pore exceeds 25% of the thinner of the nonimal wall thickness joined.The distribution of scattered porosity exceeds the concentration permitted in Figures 19 or 20.Cluster Porosity (CP)Maximum diameter of the cluster: 1/2 inch or 13mmMaximum length of CP indications in any continuous 12" length of weweld: 1/2" 13 mmMaximum length of an individual pore within a cluster: 1/16 inch or 2mmHollow Bead Porosity (HB)Maximum length of an individual indication of HB: 1/2 inch or 13mmMaximum length of HB indications in any continuous 12" length of weld: 2" 50 mmMaximum length of HB in 8% of weld: 115.0315 mmNOTE: The weld is unacceptable if individual indications of HB, each greater than 1/4 inch or 6mm in length, are seperated by less than 2 inches or 50 mm.

CRACKSNote: Any crack which is not a shallow crater crack or star crack is unacceptable.Maximum length of shallow crater cracks or star cracks: 5/32 inch or 4mm

UNDERCUTTINGUndercutting adjacent to the cover pass (EU) and Undercutting adjacent to the root pass (IU)Maximum length of EU and IU indications (in any combination) in a 12 inch length of weld: 2" 50 mmMaximum length of EU and IU indications: 9.435" 239.6490 mm (This value is 1/6 th of the total weld length)

ACCUMULATION OF IMPERFECTIONSMaximum length of AI indications in any continuous 12 inch or 300 mm length of weld: 2" 50 mmMaximum length of AI indications of 8% of weld: 115.0315 mm

RADIOGRAPHIC INFOPipe O.D. in inches: 18.00"Amount of Penetrameters required for each shot: 1 penetrameter 1" from the end of film and 1 penny in the center.Total weld length: 56.61" 1437.8940 mmCassette size to complete weld in most efficient way: 3.5 x 17" 4.5 x 17"Amount of shots to complete weld with 1" on each side of readable film: 48% of weld: 4.5288" 115.0315 mmHole penetrameters are adjacent to the weld and Wire penetrameters are parallel to the weld.

Page 2 of 2

Page 132: NDT Code Book Made Easy

PENETRAMETER SELECTIONNote: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Wire: 0.016 Esn. Wire: B4 S/S Hole: 20

F/S Wire: 0.013 Esn. Wire: B5 F/S Hole: 17Welds with reinforcement: S/S Wire: 0.016 Esn. Wire: B4 S/S Hole: 20

F/S Wire: 0.013 Esn. Wire: B5 F/S Hole: 17Maximum allowable reinforcement: 0.0625"/per sideMaximum reinforcement with DWE/SWV: 0.125" Total of walls + reinforcement: 1.249" 31.7246 mmMaximum reinforcement with DWE/DWV: 0.125" Total of walls + reinforcement: 1.249" 31.7246 mmMaximum reinforcement with SWE/SWV: 0.0625" Total of wall + reinforcement: 0.6245" 15.8623 mm

INADEQUATE PENETRATION WITHOUT HIGH LOWMaximum length of individual indication of IP : 1 inch or 25mmMaximum length of IP in 8% of weld: N/A since total weld exceeds 12 inchesMaximum length of indications in any continuous 12" length of weld: 1" 25 mm

INADEQUATE PENETRATION DUE TO HIGH LOWMaximum length of individual indication of IPD: 2 inches or 50mmMaximum length of indications of IPD in any continuous 12" length of weld: 3" 75 mm

INADEQUATE CROSS PENETRATIONMaximum length of an individual indication of ICP: 2 inches or 50mmMaximum length of indications of ICP in any continuous 12" length of weld: 2" 50 mm

INCOMPLETE FUSIONMaximum length of an individual indication of IF: 1 inch or 25mmMaximum length of IF in 8% of weld: N/A since total weld exceeds 12 inchesMaximum length of indications of IF in any continuous 12" length of weld: 1" 25 mm

INCOMPLETE FUSION DUE TO COLD LAPMaximum length of individual indications of IFD: 2 inches or 50mmMaximum length of IFD in 8% of weld: 115.0315 mmMaximum length of indications of IFD in any continuous 12" length of weld: 2" 25 mm

INTERNAL CONCAVITY Any length of IC is acceptable, provided the density of the radiographic image of the internal concavity does not exceed that of the thinnest adjacent parent material. For areas that exceed the density of thethinnest adjacent parent material, the criteria for burn through are applicable.

BURN - THROUGHMaximum dimension of BT's image : unacceptable if it exceeds that of the thinnest adjacent parent metal.Maximum dimension of BT: 1/4" or 6mmMaximum dimension is unacceptable if: it exceeds the thinner of the nonnal wall thickness joined, and the density

of the BT's image exceeds that of the thinnest adjacent parent material.The sum of the max dimensions of separate BBT's whose image density exceeds that of the thinnest adjacent parentmaterial exceeds 1/2 inch or 13mm in any continuous 12" length of weld or the total weld length(whichever is less).

API - 110418" s/40 - 0.562" Wall

Page 1 of 2

Page 133: NDT Code Book Made Easy

API - 110418" s/40 - 0.562" Wall

SLAG INCLUSIONSElongated slag inclusions (ESI)Maximum length of an ESI: 2 inches or 50mmParallel ESI indications (Wagon Tracks) shall be considered a single indication unless the width of either of them exceed1/32" or 0.8mm. In that event they shall be considered separate indications.Maximum length of ESI indications in any continuous 12" length of weld: 2" 50 mmMaximum width of an individual ESI indication: 1/16" or 1.6mmIsolated slag inclusions (ISI)Maximum length of ISI indications in any continuous 12" length of weld: 1/2" 13 mmMaximum width of an ISI indication: 1/8" or 3mmMaximum length of ESI and ISI in 8% of weld: 115.0315 mm

POROSITY Individual or Scattered Porosity.Maximum size of an individual pore: 1/8" or 3mmThe size of an individual pore exceeds 25% of the thinner of the nonimal wall thickness joined.The distribution of scattered porosity exceeds the concentration permitted in Figures 19 or 20.Cluster Porosity (CP)Maximum diameter of the cluster: 1/2 inch or 13mmMaximum length of CP indications in any continuous 12" length of weweld: 1/2" 13 mmMaximum length of an individual pore within a cluster: 1/16 inch or 2mmHollow Bead Porosity (HB)Maximum length of an individual indication of HB: 1/2 inch or 13mmMaximum length of HB indications in any continuous 12" length of weld: 2" 50 mmMaximum length of HB in 8% of weld: 115.0315 mmNOTE: The weld is unacceptable if individual indications of HB, each greater than 1/4 inch or 6mm in length, are seperated by less than 2 inches or 50 mm.

CRACKSNote: Any crack which is not a shallow crater crack or star crack is unacceptable.Maximum length of shallow crater cracks or star cracks: 5/32 inch or 4mm

UNDERCUTTINGUndercutting adjacent to the cover pass (EU) and Undercutting adjacent to the root pass (IU)Maximum length of EU and IU indications (in any combination) in a 12 inch length of weld: 2" 50 mmMaximum length of EU and IU indications: 9.435" 239.6490 mm (This value is 1/6 th of the total weld length)

ACCUMULATION OF IMPERFECTIONSMaximum length of AI indications in any continuous 12 inch or 300 mm length of weld: 2" 50 mmMaximum length of AI indications of 8% of weld: 115.0315 mm

RADIOGRAPHIC INFOPipe O.D. in inches: 18.00"Amount of Penetrameters required for each shot: 1 penetrameter 1" from the end of film and 1 penny in the center.Total weld length: 56.61" 1437.8940 mmCassette size to complete weld in most efficient way: 3.5 x 17" 4.5 x 17"Amount of shots to complete weld with 1" on each side of readable film: 48% of weld: 4.5288" 115.0315 mmHole penetrameters are adjacent to the weld and Wire penetrameters are parallel to the weld.

Page 2 of 2

Page 134: NDT Code Book Made Easy

PENETRAMETER SELECTIONNote: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Wire: 0.013 Esn. Wire: B5 S/S Hole: 17

F/S Wire: 0.010 Esn. Wire: A1 or B6 F/S Hole: 15Welds with reinforcement: S/S Wire: 0.016 Esn. Wire: B4 S/S Hole: 20

F/S Wire: 0.013 Esn. Wire: B5 F/S Hole: 17Maximum allowable reinforcement: 0.0625"/per sideMaximum reinforcement with DWE/SWV: 0.125" Total of walls + reinforcement: 1.125" 28.5750 mmMaximum reinforcement with DWE/DWV: 0.125" Total of walls + reinforcement: 1.125" 28.5750 mmMaximum reinforcement with SWE/SWV: 0.0625" Total of wall + reinforcement: 0.5625" 14.2875 mm

INADEQUATE PENETRATION WITHOUT HIGH LOWMaximum length of individual indication of IP : 1 inch or 25mmMaximum length of IP in 8% of weld: N/A since total weld exceeds 12 inchesMaximum length of indications in any continuous 12" length of weld: 1" 25 mm

INADEQUATE PENETRATION DUE TO HIGH LOWMaximum length of individual indication of IPD: 2 inches or 50mmMaximum length of indications of IPD in any continuous 12" length of weld: 3" 75 mm

INADEQUATE CROSS PENETRATIONMaximum length of an individual indication of ICP: 2 inches or 50mmMaximum length of indications of ICP in any continuous 12" length of weld: 2" 50 mm

INCOMPLETE FUSIONMaximum length of an individual indication of IF: 1 inch or 25mmMaximum length of IF in 8% of weld: N/A since total weld exceeds 12 inchesMaximum length of indications of IF in any continuous 12" length of weld: 1" 25 mm

INCOMPLETE FUSION DUE TO COLD LAPMaximum length of individual indications of IFD: 2 inches or 50mmMaximum length of IFD in 8% of weld: 115.0315 mmMaximum length of indications of IFD in any continuous 12" length of weld: 2" 25 mm

INTERNAL CONCAVITY Any length of IC is acceptable, provided the density of the radiographic image of the internal concavity does not exceed that of the thinnest adjacent parent material. For areas that exceed the density of thethinnest adjacent parent material, the criteria for burn through are applicable.

BURN - THROUGHMaximum dimension of BT's image : unacceptable if it exceeds that of the thinnest adjacent parent metal.Maximum dimension of BT: 1/4" or 6mmMaximum dimension is unacceptable if: it exceeds the thinner of the nonnal wall thickness joined, and the density

of the BT's image exceeds that of the thinnest adjacent parent material.The sum of the max dimensions of separate BBT's whose image density exceeds that of the thinnest adjacent parentmaterial exceeds 1/2 inch or 13mm in any continuous 12" length of weld or the total weld length(whichever is less).

API - 110418" Extra Strong - 0.500" Wall

Page 1 of 2

Page 135: NDT Code Book Made Easy

API - 110418" Extra Strong - 0.500" Wall

SLAG INCLUSIONSElongated slag inclusions (ESI)Maximum length of an ESI: 2 inches or 50mmParallel ESI indications (Wagon Tracks) shall be considered a single indication unless the width of either of them exceed1/32" or 0.8mm. In that event they shall be considered separate indications.Maximum length of ESI indications in any continuous 12" length of weld: 2" 50 mmMaximum width of an individual ESI indication: 1/16" or 1.6mmIsolated slag inclusions (ISI)Maximum length of ISI indications in any continuous 12" length of weld: 1/2" 13 mmMaximum width of an ISI indication: 1/8" or 3mmMaximum length of ESI and ISI in 8% of weld: 115.0315 mm

POROSITY Individual or Scattered Porosity.Maximum size of an individual pore: 1/8" or 3mmThe size of an individual pore exceeds 25% of the thinner of the nonimal wall thickness joined.The distribution of scattered porosity exceeds the concentration permitted in Figures 19 or 20.Cluster Porosity (CP)Maximum diameter of the cluster: 1/2 inch or 13mmMaximum length of CP indications in any continuous 12" length of weweld: 1/2" 13 mmMaximum length of an individual pore within a cluster: 1/16 inch or 2mmHollow Bead Porosity (HB)Maximum length of an individual indication of HB: 1/2 inch or 13mmMaximum length of HB indications in any continuous 12" length of weld: 2" 50 mmMaximum length of HB in 8% of weld: 115.0315 mmNOTE: The weld is unacceptable if individual indications of HB, each greater than 1/4 inch or 6mm in length, are seperated by less than 2 inches or 50 mm.

CRACKSNote: Any crack which is not a shallow crater crack or star crack is unacceptable.Maximum length of shallow crater cracks or star cracks: 5/32 inch or 4mm

UNDERCUTTINGUndercutting adjacent to the cover pass (EU) and Undercutting adjacent to the root pass (IU)Maximum length of EU and IU indications (in any combination) in a 12 inch length of weld: 2" 50 mmMaximum length of EU and IU indications: 9.435" 239.6490 mm (This value is 1/6 th of the total weld length)

ACCUMULATION OF IMPERFECTIONSMaximum length of AI indications in any continuous 12 inch or 300 mm length of weld: 2" 50 mmMaximum length of AI indications of 8% of weld: 115.0315 mm

RADIOGRAPHIC INFOPipe O.D. in inches: 18.00"Amount of Penetrameters required for each shot: 1 penetrameter 1" from the end of film and 1 penny in the center.Total weld length: 56.61" 1437.8940 mmCassette size to complete weld in most efficient way: 3.5 x 17" 4.5 x 17"Amount of shots to complete weld with 1" on each side of readable film: 48% of weld: 4.5288" 115.0315 mmHole penetrameters are adjacent to the weld and Wire penetrameters are parallel to the weld.

Page 2 of 2

Page 136: NDT Code Book Made Easy

PENETRAMETER SELECTIONNote: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Wire: 0.020 Esn. Wire: B3 S/S Hole: 25

F/S Wire: 0.016 Esn. Wire: B4 F/S Hole: 20Welds with reinforcement: S/S Wire: 0.020 Esn. Wire: B3 S/S Hole: 25

F/S Wire: 0.016 Esn. Wire: B4 F/S Hole: 20Maximum allowable reinforcement: 0.0625"/per sideMaximum reinforcement with DWE/SWV: 0.125" Total of walls + reinforcement: 1.999" 50.7746 mmMaximum reinforcement with DWE/DWV: 0.125" Total of walls + reinforcement: 1.999" 50.7746 mmMaximum reinforcement with SWE/SWV: 0.0625" Total of wall + reinforcement: 0.9995" 25.3873 mm

INADEQUATE PENETRATION WITHOUT HIGH LOWMaximum length of individual indication of IP : 1 inch or 25mmMaximum length of IP in 8% of weld: N/A since total weld exceeds 12 inchesMaximum length of indications in any continuous 12" length of weld: 1" 25 mm

INADEQUATE PENETRATION DUE TO HIGH LOWMaximum length of individual indication of IPD: 2 inches or 50mmMaximum length of indications of IPD in any continuous 12" length of weld: 3" 75 mm

INADEQUATE CROSS PENETRATIONMaximum length of an individual indication of ICP: 2 inches or 50mmMaximum length of indications of ICP in any continuous 12" length of weld: 2" 50 mm

INCOMPLETE FUSIONMaximum length of an individual indication of IF: 1 inch or 25mmMaximum length of IF in 8% of weld: N/A since total weld exceeds 12 inchesMaximum length of indications of IF in any continuous 12" length of weld: 1" 25 mm

INCOMPLETE FUSION DUE TO COLD LAPMaximum length of individual indications of IFD: 2 inches or 50mmMaximum length of IFD in 8% of weld: 115.0315 mmMaximum length of indications of IFD in any continuous 12" length of weld: 2" 25 mm

INTERNAL CONCAVITY Any length of IC is acceptable, provided the density of the radiographic image of the internal concavity does not exceed that of the thinnest adjacent parent material. For areas that exceed the density of thethinnest adjacent parent material, the criteria for burn through are applicable.

BURN - THROUGHMaximum dimension of BT's image : unacceptable if it exceeds that of the thinnest adjacent parent metal.Maximum dimension of BT: 1/4" or 6mmMaximum dimension is unacceptable if: it exceeds the thinner of the nonnal wall thickness joined, and the density

of the BT's image exceeds that of the thinnest adjacent parent material.The sum of the max dimensions of separate BBT's whose image density exceeds that of the thinnest adjacent parentmaterial exceeds 1/2 inch or 13mm in any continuous 12" length of weld or the total weld length(whichever is less).

API - 110418" s/80 - 0.937" Wall

Page 1 of 2

Page 137: NDT Code Book Made Easy

API - 110418" s/80 - 0.937" Wall

SLAG INCLUSIONSElongated slag inclusions (ESI)Maximum length of an ESI: 2 inches or 50mmParallel ESI indications (Wagon Tracks) shall be considered a single indication unless the width of either of them exceed1/32" or 0.8mm. In that event they shall be considered separate indications.Maximum length of ESI indications in any continuous 12" length of weld: 2" 50 mmMaximum width of an individual ESI indication: 1/16" or 1.6mmIsolated slag inclusions (ISI)Maximum length of ISI indications in any continuous 12" length of weld: 1/2" 13 mmMaximum width of an ISI indication: 1/8" or 3mmMaximum length of ESI and ISI in 8% of weld: 115.0315 mm

POROSITY Individual or Scattered Porosity.Maximum size of an individual pore: 1/8" or 3mmThe size of an individual pore exceeds 25% of the thinner of the nonimal wall thickness joined.The distribution of scattered porosity exceeds the concentration permitted in Figures 19 or 20.Cluster Porosity (CP)Maximum diameter of the cluster: 1/2 inch or 13mmMaximum length of CP indications in any continuous 12" length of weweld: 1/2" 13 mmMaximum length of an individual pore within a cluster: 1/16 inch or 2mmHollow Bead Porosity (HB)Maximum length of an individual indication of HB: 1/2 inch or 13mmMaximum length of HB indications in any continuous 12" length of weld: 2" 50 mmMaximum length of HB in 8% of weld: 115.0315 mmNOTE: The weld is unacceptable if individual indications of HB, each greater than 1/4 inch or 6mm in length, are seperated by less than 2 inches or 50 mm.

CRACKSNote: Any crack which is not a shallow crater crack or star crack is unacceptable.Maximum length of shallow crater cracks or star cracks: 5/32 inch or 4mm

UNDERCUTTINGUndercutting adjacent to the cover pass (EU) and Undercutting adjacent to the root pass (IU)Maximum length of EU and IU indications (in any combination) in a 12 inch length of weld: 2" 50 mmMaximum length of EU and IU indications: 9.435" 239.6490 mm (This value is 1/6 th of the total weld length)

ACCUMULATION OF IMPERFECTIONSMaximum length of AI indications in any continuous 12 inch or 300 mm length of weld: 2" 50 mmMaximum length of AI indications of 8% of weld: 115.0315 mm

RADIOGRAPHIC INFOPipe O.D. in inches: 18.00"Amount of Penetrameters required for each shot: 1 penetrameter 1" from the end of film and 1 penny in the center.Total weld length: 56.61" 1437.8940 mmCassette size to complete weld in most efficient way: 3.5 x 17" 4.5 x 17"Amount of shots to complete weld with 1" on each side of readable film: 48% of weld: 4.5288" 115.0315 mmHole penetrameters are adjacent to the weld and Wire penetrameters are parallel to the weld.

Page 2 of 2

Page 138: NDT Code Book Made Easy

PENETRAMETER SELECTIONNote: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Wire: 0.025 Esn. Wire: B2 S/S Hole: 30

F/S Wire: 0.020 Esn. Wire: B3 F/S Hole: 25Welds with reinforcement: S/S Wire: 0.032 Esn. Wire: B1 or C6 S/S Hole: 35

F/S Wire: 0.025 Esn. Wire: B2 F/S Hole: 30Maximum allowable reinforcement: 0.0625"/per sideMaximum reinforcement with DWE/SWV: 0.125" Total of walls + reinforcement: 2.875" 73.0250 mmMaximum reinforcement with DWE/DWV: 0.125" Total of walls + reinforcement: 2.875" 73.0250 mmMaximum reinforcement with SWE/SWV: 0.0625" Total of wall + reinforcement: 1.4375" 36.5125 mm

INADEQUATE PENETRATION WITHOUT HIGH LOWMaximum length of individual indication of IP : 1 inch or 25mmMaximum length of IP in 8% of weld: N/A since total weld exceeds 12 inchesMaximum length of indications in any continuous 12" length of weld: 1" 25 mm

INADEQUATE PENETRATION DUE TO HIGH LOWMaximum length of individual indication of IPD: 2 inches or 50mmMaximum length of indications of IPD in any continuous 12" length of weld: 3" 75 mm

INADEQUATE CROSS PENETRATIONMaximum length of an individual indication of ICP: 2 inches or 50mmMaximum length of indications of ICP in any continuous 12" length of weld: 2" 50 mm

INCOMPLETE FUSIONMaximum length of an individual indication of IF: 1 inch or 25mmMaximum length of IF in 8% of weld: N/A since total weld exceeds 12 inchesMaximum length of indications of IF in any continuous 12" length of weld: 1" 25 mm

INCOMPLETE FUSION DUE TO COLD LAPMaximum length of individual indications of IFD: 2 inches or 50mmMaximum length of IFD in 8% of weld: 115.0315 mmMaximum length of indications of IFD in any continuous 12" length of weld: 2" 25 mm

INTERNAL CONCAVITY Any length of IC is acceptable, provided the density of the radiographic image of the internal concavity does not exceed that of the thinnest adjacent parent material. For areas that exceed the density of thethinnest adjacent parent material, the criteria for burn through are applicable.

BURN - THROUGHMaximum dimension of BT's image : unacceptable if it exceeds that of the thinnest adjacent parent metal.Maximum dimension of BT: 1/4" or 6mmMaximum dimension is unacceptable if: it exceeds the thinner of the nonnal wall thickness joined, and the density

of the BT's image exceeds that of the thinnest adjacent parent material.The sum of the max dimensions of separate BBT's whose image density exceeds that of the thinnest adjacent parentmaterial exceeds 1/2 inch or 13mm in any continuous 12" length of weld or the total weld length(whichever is less).

API - 110418" s/120 - 1.375" Wall

Page 1 of 2

Page 139: NDT Code Book Made Easy

API - 110418" s/120 - 1.375" Wall

SLAG INCLUSIONSElongated slag inclusions (ESI)Maximum length of an ESI: 2 inches or 50mmParallel ESI indications (Wagon Tracks) shall be considered a single indication unless the width of either of them exceed1/32" or 0.8mm. In that event they shall be considered separate indications.Maximum length of ESI indications in any continuous 12" length of weld: 2" 50 mmMaximum width of an individual ESI indication: 1/16" or 1.6mmIsolated slag inclusions (ISI)Maximum length of ISI indications in any continuous 12" length of weld: 1/2" 13 mmMaximum width of an ISI indication: 1/8" or 3mmMaximum length of ESI and ISI in 8% of weld: 115.0315 mm

POROSITY Individual or Scattered Porosity.Maximum size of an individual pore: 1/8" or 3mmThe size of an individual pore exceeds 25% of the thinner of the nonimal wall thickness joined.The distribution of scattered porosity exceeds the concentration permitted in Figures 19 or 20.Cluster Porosity (CP)Maximum diameter of the cluster: 1/2 inch or 13mmMaximum length of CP indications in any continuous 12" length of weweld: 1/2" 13 mmMaximum length of an individual pore within a cluster: 1/16 inch or 2mmHollow Bead Porosity (HB)Maximum length of an individual indication of HB: 1/2 inch or 13mmMaximum length of HB indications in any continuous 12" length of weld: 2" 50 mmMaximum length of HB in 8% of weld: 115.0315 mmNOTE: The weld is unacceptable if individual indications of HB, each greater than 1/4 inch or 6mm in length, are seperated by less than 2 inches or 50 mm.

CRACKSNote: Any crack which is not a shallow crater crack or star crack is unacceptable.Maximum length of shallow crater cracks or star cracks: 5/32 inch or 4mm

UNDERCUTTINGUndercutting adjacent to the cover pass (EU) and Undercutting adjacent to the root pass (IU)Maximum length of EU and IU indications (in any combination) in a 12 inch length of weld: 2" 50 mmMaximum length of EU and IU indications: 9.435" 239.6490 mm (This value is 1/6 th of the total weld length)

ACCUMULATION OF IMPERFECTIONSMaximum length of AI indications in any continuous 12 inch or 300 mm length of weld: 2" 50 mmMaximum length of AI indications of 8% of weld: 115.0315 mm

RADIOGRAPHIC INFOPipe O.D. in inches: 18.00"Amount of Penetrameters required for each shot: 1 penetrameter 1" from the end of film and 1 penny in the center.Total weld length: 56.61" 1437.8940 mmCassette size to complete weld in most efficient way: 3.5 x 17" 4.5 x 17"Amount of shots to complete weld with 1" on each side of readable film: 58% of weld: 4.5288" 115.0315 mmHole penetrameters are adjacent to the weld and Wire penetrameters are parallel to the weld.

Page 2 of 2

Page 140: NDT Code Book Made Easy

PENETRAMETER SELECTIONNote: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Wire: 0.032 Esn. Wire: B1 or C6 S/S Hole: 35

F/S Wire: 0.025 Esn. Wire: B2 F/S Hole: 30Welds with reinforcement: S/S Wire: 0.040 Esn. Wire: C5 S/S Hole: 40

F/S Wire: 0.032 Esn. Wire: B1 or C6 F/S Hole: 35Maximum allowable reinforcement: 0.0625"/per sideMaximum reinforcement with DWE/SWV: 0.125" Total of walls + reinforcement: 3.249" 82.5246 mmMaximum reinforcement with DWE/DWV: 0.125" Total of walls + reinforcement: 3.249" 82.5246 mmMaximum reinforcement with SWE/SWV: 0.0625" Total of wall + reinforcement: 1.6245" 41.2623 mm

INADEQUATE PENETRATION WITHOUT HIGH LOWMaximum length of individual indication of IP : 1 inch or 25mmMaximum length of IP in 8% of weld: N/A since total weld exceeds 12 inchesMaximum length of indications in any continuous 12" length of weld: 1" 25 mm

INADEQUATE PENETRATION DUE TO HIGH LOWMaximum length of individual indication of IPD: 2 inches or 50mmMaximum length of indications of IPD in any continuous 12" length of weld: 3" 75 mm

INADEQUATE CROSS PENETRATIONMaximum length of an individual indication of ICP: 2 inches or 50mmMaximum length of indications of ICP in any continuous 12" length of weld: 2" 50 mm

INCOMPLETE FUSIONMaximum length of an individual indication of IF: 1 inch or 25mmMaximum length of IF in 8% of weld: N/A since total weld exceeds 12 inchesMaximum length of indications of IF in any continuous 12" length of weld: 1" 25 mm

INCOMPLETE FUSION DUE TO COLD LAPMaximum length of individual indications of IFD: 2 inches or 50mmMaximum length of IFD in 8% of weld: 115.0315 mmMaximum length of indications of IFD in any continuous 12" length of weld: 2" 25 mm

INTERNAL CONCAVITY Any length of IC is acceptable, provided the density of the radiographic image of the internal concavity does not exceed that of the thinnest adjacent parent material. For areas that exceed the density of thethinnest adjacent parent material, the criteria for burn through are applicable.

BURN - THROUGHMaximum dimension of BT's image : unacceptable if it exceeds that of the thinnest adjacent parent metal.Maximum dimension of BT: 1/4" or 6mmMaximum dimension is unacceptable if: it exceeds the thinner of the nonnal wall thickness joined, and the density

of the BT's image exceeds that of the thinnest adjacent parent material.The sum of the max dimensions of separate BBT's whose image density exceeds that of the thinnest adjacent parentmaterial exceeds 1/2 inch or 13mm in any continuous 12" length of weld or the total weld length(whichever is less).

API - 110418" s/140 - 1.562" Wall

Page 1 of 2

Page 141: NDT Code Book Made Easy

API - 110418" s/140 - 1.562" Wall

SLAG INCLUSIONSElongated slag inclusions (ESI)Maximum length of an ESI: 2 inches or 50mmParallel ESI indications (Wagon Tracks) shall be considered a single indication unless the width of either of them exceed1/32" or 0.8mm. In that event they shall be considered separate indications.Maximum length of ESI indications in any continuous 12" length of weld: 2" 50 mmMaximum width of an individual ESI indication: 1/16" or 1.6mmIsolated slag inclusions (ISI)Maximum length of ISI indications in any continuous 12" length of weld: 1/2" 13 mmMaximum width of an ISI indication: 1/8" or 3mmMaximum length of ESI and ISI in 8% of weld: 115.0315 mm

POROSITY Individual or Scattered Porosity.Maximum size of an individual pore: 1/8" or 3mmThe size of an individual pore exceeds 25% of the thinner of the nonimal wall thickness joined.The distribution of scattered porosity exceeds the concentration permitted in Figures 19 or 20.Cluster Porosity (CP)Maximum diameter of the cluster: 1/2 inch or 13mmMaximum length of CP indications in any continuous 12" length of weweld: 1/2" 13 mmMaximum length of an individual pore within a cluster: 1/16 inch or 2mmHollow Bead Porosity (HB)Maximum length of an individual indication of HB: 1/2 inch or 13mmMaximum length of HB indications in any continuous 12" length of weld: 2" 50 mmMaximum length of HB in 8% of weld: 115.0315 mmNOTE: The weld is unacceptable if individual indications of HB, each greater than 1/4 inch or 6mm in length, are seperated by less than 2 inches or 50 mm.

CRACKSNote: Any crack which is not a shallow crater crack or star crack is unacceptable.Maximum length of shallow crater cracks or star cracks: 5/32 inch or 4mm

UNDERCUTTINGUndercutting adjacent to the cover pass (EU) and Undercutting adjacent to the root pass (IU)Maximum length of EU and IU indications (in any combination) in a 12 inch length of weld: 2" 50 mmMaximum length of EU and IU indications: 9.435" 239.6490 mm (This value is 1/6 th of the total weld length)

ACCUMULATION OF IMPERFECTIONSMaximum length of AI indications in any continuous 12 inch or 300 mm length of weld: 2" 50 mmMaximum length of AI indications of 8% of weld: 115.0315 mm

RADIOGRAPHIC INFOPipe O.D. in inches: 18.00"Amount of Penetrameters required for each shot: 1 penetrameter 1" from the end of film and 1 penny in the center.Total weld length: 56.61" 1437.8940 mmCassette size to complete weld in most efficient way: 3.5 x 17" 4.5 x 17"Amount of shots to complete weld with 1" on each side of readable film: 58% of weld: 4.5288" 115.0315 mmHole penetrameters are adjacent to the weld and Wire penetrameters are parallel to the weld.

Page 2 of 2

Page 142: NDT Code Book Made Easy

PENETRAMETER SELECTIONNote: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Wire: 0.032 Esn. Wire: B1 or C6 S/S Hole: 35

F/S Wire: 0.025 Esn. Wire: B2 F/S Hole: 30Welds with reinforcement: S/S Wire: 0.040 Esn. Wire: C5 S/S Hole: 40

F/S Wire: 0.032 Esn. Wire: B1 or C6 F/S Hole: 35Maximum allowable reinforcement: 0.0625"/per sideMaximum reinforcement with DWE/SWV: 0.125" Total of walls + reinforcement: 3.687" 93.6498 mmMaximum reinforcement with DWE/DWV: 0.125" Total of walls + reinforcement: 3.687" 93.6498 mmMaximum reinforcement with SWE/SWV: 0.0625" Total of wall + reinforcement: 1.8435" 46.8249 mm

INADEQUATE PENETRATION WITHOUT HIGH LOWMaximum length of individual indication of IP : 1 inch or 25mmMaximum length of IP in 8% of weld: N/A since total weld exceeds 12 inchesMaximum length of indications in any continuous 12" length of weld: 1" 25 mm

INADEQUATE PENETRATION DUE TO HIGH LOWMaximum length of individual indication of IPD: 2 inches or 50mmMaximum length of indications of IPD in any continuous 12" length of weld: 3" 75 mm

INADEQUATE CROSS PENETRATIONMaximum length of an individual indication of ICP: 2 inches or 50mmMaximum length of indications of ICP in any continuous 12" length of weld: 2" 50 mm

INCOMPLETE FUSIONMaximum length of an individual indication of IF: 1 inch or 25mmMaximum length of IF in 8% of weld: N/A since total weld exceeds 12 inchesMaximum length of indications of IF in any continuous 12" length of weld: 1" 25 mm

INCOMPLETE FUSION DUE TO COLD LAPMaximum length of individual indications of IFD: 2 inches or 50mmMaximum length of IFD in 8% of weld: 115.0315 mmMaximum length of indications of IFD in any continuous 12" length of weld: 2" 25 mm

INTERNAL CONCAVITY Any length of IC is acceptable, provided the density of the radiographic image of the internal concavity does not exceed that of the thinnest adjacent parent material. For areas that exceed the density of thethinnest adjacent parent material, the criteria for burn through are applicable.

BURN - THROUGHMaximum dimension of BT's image : unacceptable if it exceeds that of the thinnest adjacent parent metal.Maximum dimension of BT: 1/4" or 6mmMaximum dimension is unacceptable if: it exceeds the thinner of the nonnal wall thickness joined, and the density

of the BT's image exceeds that of the thinnest adjacent parent material.The sum of the max dimensions of separate BBT's whose image density exceeds that of the thinnest adjacent parentmaterial exceeds 1/2 inch or 13mm in any continuous 12" length of weld or the total weld length(whichever is less).

API - 110418" s/160 - 1.781" Wall

Page 1 of 2

Page 143: NDT Code Book Made Easy

API - 110418" s/160 - 1.781" Wall

SLAG INCLUSIONSElongated slag inclusions (ESI)Maximum length of an ESI: 2 inches or 50mmParallel ESI indications (Wagon Tracks) shall be considered a single indication unless the width of either of them exceed1/32" or 0.8mm. In that event they shall be considered separate indications.Maximum length of ESI indications in any continuous 12" length of weld: 2" 50 mmMaximum width of an individual ESI indication: 1/16" or 1.6mmIsolated slag inclusions (ISI)Maximum length of ISI indications in any continuous 12" length of weld: 1/2" 13 mmMaximum width of an ISI indication: 1/8" or 3mmMaximum length of ESI and ISI in 8% of weld: 115.0315 mm

POROSITY Individual or Scattered Porosity.Maximum size of an individual pore: 1/8" or 3mmThe size of an individual pore exceeds 25% of the thinner of the nonimal wall thickness joined.The distribution of scattered porosity exceeds the concentration permitted in Figures 19 or 20.Cluster Porosity (CP)Maximum diameter of the cluster: 1/2 inch or 13mmMaximum length of CP indications in any continuous 12" length of weweld: 1/2" 13 mmMaximum length of an individual pore within a cluster: 1/16 inch or 2mmHollow Bead Porosity (HB)Maximum length of an individual indication of HB: 1/2 inch or 13mmMaximum length of HB indications in any continuous 12" length of weld: 2" 50 mmMaximum length of HB in 8% of weld: 115.0315 mmNOTE: The weld is unacceptable if individual indications of HB, each greater than 1/4 inch or 6mm in length, are seperated by less than 2 inches or 50 mm.

CRACKSNote: Any crack which is not a shallow crater crack or star crack is unacceptable.Maximum length of shallow crater cracks or star cracks: 5/32 inch or 4mm

UNDERCUTTINGUndercutting adjacent to the cover pass (EU) and Undercutting adjacent to the root pass (IU)Maximum length of EU and IU indications (in any combination) in a 12 inch length of weld: 2" 50 mmMaximum length of EU and IU indications: 9.435" 239.6490 mm (This value is 1/6 th of the total weld length)

ACCUMULATION OF IMPERFECTIONSMaximum length of AI indications in any continuous 12 inch or 300 mm length of weld: 2" 50 mmMaximum length of AI indications of 8% of weld: 115.0315 mm

RADIOGRAPHIC INFOPipe O.D. in inches: 18.00"Amount of Penetrameters required for each shot: 1 penetrameter 1" from the end of film and 1 penny in the center.Total weld length: 56.61" 1437.8940 mmCassette size to complete weld in most efficient way: 3.5 x 17" 4.5 x 17"Amount of shots to complete weld with 1" on each side of readable film: 68% of weld: 4.5288" 115.0315 mmHole penetrameters are adjacent to the weld and Wire penetrameters are parallel to the weld.

Page 2 of 2

Page 144: NDT Code Book Made Easy

PENETRAMETER SELECTIONNote: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Wire: 0.008 Esn. Wire: A2 S/S Hole: 12

F/S Wire: 0.006 Esn. Wire: A3 F/S Hole: 10Welds with reinforcement: S/S Wire: 0.010 Esn. Wire: A1 or B6 S/S Hole: 15

F/S Wire: 0.008 Esn. Wire: A2 F/S Hole: 12Maximum allowable reinforcement: 0.0625"/per sideMaximum reinforcement with DWE/SWV: 0.125" Total of walls + reinforcement: 0.625" 15.8750 mmMaximum reinforcement with DWE/DWV: 0.125" Total of walls + reinforcement: 0.625" 15.8750 mmMaximum reinforcement with SWE/SWV: 0.0625" Total of wall + reinforcement: 0.3125" 7.9375 mm

INADEQUATE PENETRATION WITHOUT HIGH LOWMaximum length of individual indication of IP : 1 inch or 25mmMaximum length of IP in 8% of weld: N/A since total weld exceeds 12 inchesMaximum length of indications in any continuous 12" length of weld: 1" 25 mm

INADEQUATE PENETRATION DUE TO HIGH LOWMaximum length of individual indication of IPD: 2 inches or 50mmMaximum length of indications of IPD in any continuous 12" length of weld: 3" 75 mm

INADEQUATE CROSS PENETRATIONMaximum length of an individual indication of ICP: 2 inches or 50mmMaximum length of indications of ICP in any continuous 12" length of weld: 2" 50 mm

INCOMPLETE FUSIONMaximum length of an individual indication of IF: 1 inch or 25mmMaximum length of IF in 8% of weld: N/A since total weld exceeds 12 inchesMaximum length of indications of IF in any continuous 12" length of weld: 1" 25 mm

INCOMPLETE FUSION DUE TO COLD LAPMaximum length of individual indications of IFD: 2 inches or 50mmMaximum length of IFD in 8% of weld: 127.8128 mmMaximum length of indications of IFD in any continuous 12" length of weld: 2" 25 mm

INTERNAL CONCAVITY Any length of IC is acceptable, provided the density of the radiographic image of the internal concavity does not exceed that of the thinnest adjacent parent material. For areas that exceed the density of thethinnest adjacent parent material, the criteria for burn through are applicable.

BURN - THROUGHMaximum dimension of BT's image : unacceptable if it exceeds that of the thinnest adjacent parent metal.Maximum dimension of BT: 1/4" or 6mmMaximum dimension is unacceptable if: it exceeds the thinner of the nonnal wall thickness joined, and the density

of the BT's image exceeds that of the thinnest adjacent parent material.The sum of the max dimensions of separate BBT's whose image density exceeds that of the thinnest adjacent parentmaterial exceeds 1/2 inch or 13mm in any continuous 12" length of weld or the total weld length(whichever is less).

API - 110420" s/10 - 0.250" Wall

Page 1 of 2

Page 145: NDT Code Book Made Easy

API - 110420" s/10 - 0.250" Wall

SLAG INCLUSIONSElongated slag inclusions (ESI)Maximum length of an ESI: 2 inches or 50mmParallel ESI indications (Wagon Tracks) shall be considered a single indication unless the width of either of them exceed1/32" or 0.8mm. In that event they shall be considered separate indications.Maximum length of ESI indications in any continuous 12" length of weld: 2" 50 mmMaximum width of an individual ESI indication: 1/16" or 1.6mmIsolated slag inclusions (ISI)Maximum length of ISI indications in any continuous 12" length of weld: 1/2" 13 mmMaximum width of an ISI indication: 1/8" or 3mmMaximum length of ESI and ISI in 8% of weld: 127.8128 mm

POROSITY Individual or Scattered Porosity.Maximum size of an individual pore: 1/8" or 3mmThe size of an individual pore exceeds 25% of the thinner of the nonimal wall thickness joined.The distribution of scattered porosity exceeds the concentration permitted in Figures 19 or 20.Cluster Porosity (CP)Maximum diameter of the cluster: 1/2 inch or 13mmMaximum length of CP indications in any continuous 12" length of weweld: 1/2" 13 mmMaximum length of an individual pore within a cluster: 1/16 inch or 2mmHollow Bead Porosity (HB)Maximum length of an individual indication of HB: 1/2 inch or 13mmMaximum length of HB indications in any continuous 12" length of weld: 2" 50 mmMaximum length of HB in 8% of weld: 127.8128 mmNOTE: The weld is unacceptable if individual indications of HB, each greater than 1/4 inch or 6mm in length, are seperated by less than 2 inches or 50 mm.

CRACKSNote: Any crack which is not a shallow crater crack or star crack is unacceptable.Maximum length of shallow crater cracks or star cracks: 5/32 inch or 4mm

UNDERCUTTINGUndercutting adjacent to the cover pass (EU) and Undercutting adjacent to the root pass (IU)Maximum length of EU and IU indications (in any combination) in a 12 inch length of weld: 2" 50 mmMaximum length of EU and IU indications: 10.4833" 266.2758 mm (This value is 1/6 th of the total weld length)

ACCUMULATION OF IMPERFECTIONSMaximum length of AI indications in any continuous 12 inch or 300 mm length of weld: 2" 50 mmMaximum length of AI indications of 8% of weld: 127.8128 mm

RADIOGRAPHIC INFOPipe O.D. in inches: 20.00"Amount of Penetrameters required for each shot: 1 penetrameter 1" from the end of film and 1 penny in the center.Total weld length: 62.9" 1597.6600 mmCassette size to complete weld in most efficient way: 3.5 x 17" 4.5 x 17"Amount of shots to complete weld with 1" on each side of readable film: 58% of weld: 5.032" 127.8128 mmHole penetrameters are adjacent to the weld and Wire penetrameters are parallel to the weld.

Page 2 of 2

Page 146: NDT Code Book Made Easy

PENETRAMETER SELECTIONNote: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Wire: 0.010 Esn. Wire: A1 or B6 S/S Hole: 15

F/S Wire: 0.008 Esn. Wire: A2 F/S Hole: 12Welds with reinforcement: S/S Wire: 0.013 Esn. Wire: B5 S/S Hole: 17

F/S Wire: 0.010 Esn. Wire: A1 or B6 F/S Hole: 15Maximum allowable reinforcement: 0.0625"/per sideMaximum reinforcement with DWE/SWV: 0.125" Total of walls + reinforcement: 0.875" 22.2250 mmMaximum reinforcement with DWE/DWV: 0.125" Total of walls + reinforcement: 0.875" 22.2250 mmMaximum reinforcement with SWE/SWV: 0.0625" Total of wall + reinforcement: 0.4375" 11.1125 mm

INADEQUATE PENETRATION WITHOUT HIGH LOWMaximum length of individual indication of IP : 1 inch or 25mmMaximum length of IP in 8% of weld: N/A since total weld exceeds 12 inchesMaximum length of indications in any continuous 12" length of weld: 1" 25 mm

INADEQUATE PENETRATION DUE TO HIGH LOWMaximum length of individual indication of IPD: 2 inches or 50mmMaximum length of indications of IPD in any continuous 12" length of weld: 3" 75 mm

INADEQUATE CROSS PENETRATIONMaximum length of an individual indication of ICP: 2 inches or 50mmMaximum length of indications of ICP in any continuous 12" length of weld: 2" 50 mm

INCOMPLETE FUSIONMaximum length of an individual indication of IF: 1 inch or 25mmMaximum length of IF in 8% of weld: N/A since total weld exceeds 12 inchesMaximum length of indications of IF in any continuous 12" length of weld: 1" 25 mm

INCOMPLETE FUSION DUE TO COLD LAPMaximum length of individual indications of IFD: 2 inches or 50mmMaximum length of IFD in 8% of weld: 127.8128 mmMaximum length of indications of IFD in any continuous 12" length of weld: 2" 25 mm

INTERNAL CONCAVITY Any length of IC is acceptable, provided the density of the radiographic image of the internal concavity does not exceed that of the thinnest adjacent parent material. For areas that exceed the density of thethinnest adjacent parent material, the criteria for burn through are applicable.

BURN - THROUGHMaximum dimension of BT's image : unacceptable if it exceeds that of the thinnest adjacent parent metal.Maximum dimension of BT: 1/4" or 6mmMaximum dimension is unacceptable if: it exceeds the thinner of the nonnal wall thickness joined, and the density

of the BT's image exceeds that of the thinnest adjacent parent material.The sum of the max dimensions of separate BBT's whose image density exceeds that of the thinnest adjacent parentmaterial exceeds 1/2 inch or 13mm in any continuous 12" length of weld or the total weld length(whichever is less).

API - 110420" Standard - 0.375" Wall

Page 1 of 2

Page 147: NDT Code Book Made Easy

API - 110420" Standard - 0.375" Wall

SLAG INCLUSIONSElongated slag inclusions (ESI)Maximum length of an ESI: 2 inches or 50mmParallel ESI indications (Wagon Tracks) shall be considered a single indication unless the width of either of them exceed1/32" or 0.8mm. In that event they shall be considered separate indications.Maximum length of ESI indications in any continuous 12" length of weld: 2" 50 mmMaximum width of an individual ESI indication: 1/16" or 1.6mmIsolated slag inclusions (ISI)Maximum length of ISI indications in any continuous 12" length of weld: 1/2" 13 mmMaximum width of an ISI indication: 1/8" or 3mmMaximum length of ESI and ISI in 8% of weld: 127.8128 mm

POROSITY Individual or Scattered Porosity.Maximum size of an individual pore: 1/8" or 3mmThe size of an individual pore exceeds 25% of the thinner of the nonimal wall thickness joined.The distribution of scattered porosity exceeds the concentration permitted in Figures 19 or 20.Cluster Porosity (CP)Maximum diameter of the cluster: 1/2 inch or 13mmMaximum length of CP indications in any continuous 12" length of weweld: 1/2" 13 mmMaximum length of an individual pore within a cluster: 1/16 inch or 2mmHollow Bead Porosity (HB)Maximum length of an individual indication of HB: 1/2 inch or 13mmMaximum length of HB indications in any continuous 12" length of weld: 2" 50 mmMaximum length of HB in 8% of weld: 127.8128 mmNOTE: The weld is unacceptable if individual indications of HB, each greater than 1/4 inch or 6mm in length, are seperated by less than 2 inches or 50 mm.

CRACKSNote: Any crack which is not a shallow crater crack or star crack is unacceptable.Maximum length of shallow crater cracks or star cracks: 5/32 inch or 4mm

UNDERCUTTINGUndercutting adjacent to the cover pass (EU) and Undercutting adjacent to the root pass (IU)Maximum length of EU and IU indications (in any combination) in a 12 inch length of weld: 2" 50 mmMaximum length of EU and IU indications: 10.4833" 266.2758 mm (This value is 1/6 th of the total weld length)

ACCUMULATION OF IMPERFECTIONSMaximum length of AI indications in any continuous 12 inch or 300 mm length of weld: 2" 50 mmMaximum length of AI indications of 8% of weld: 127.8128 mm

RADIOGRAPHIC INFOPipe O.D. in inches: 20.00"Amount of Penetrameters required for each shot: 1 penetrameter 1" from the end of film and 1 penny in the center.Total weld length: 62.9" 1597.6600 mmCassette size to complete weld in most efficient way: 3.5 x 17" 4.5 x 17"Amount of shots to complete weld with 1" on each side of readable film: 58% of weld: 5.032" 127.8128 mmHole penetrameters are adjacent to the weld and Wire penetrameters are parallel to the weld.

Page 2 of 2

Page 148: NDT Code Book Made Easy

PENETRAMETER SELECTIONNote: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Wire: 0.016 Esn. Wire: B4 S/S Hole: 20

F/S Wire: 0.013 Esn. Wire: B5 F/S Hole: 17Welds with reinforcement: S/S Wire: 0.016 Esn. Wire: B4 S/S Hole: 20

F/S Wire: 0.013 Esn. Wire: B5 F/S Hole: 17Maximum allowable reinforcement: 0.0625"/per sideMaximum reinforcement with DWE/SWV: 0.125" Total of walls + reinforcement: 1.313" 33.3502 mmMaximum reinforcement with DWE/DWV: 0.125" Total of walls + reinforcement: 1.313" 33.3502 mmMaximum reinforcement with SWE/SWV: 0.0625" Total of wall + reinforcement: 0.6565" 16.6751 mm

INADEQUATE PENETRATION WITHOUT HIGH LOWMaximum length of individual indication of IP : 1 inch or 25mmMaximum length of IP in 8% of weld: N/A since total weld exceeds 12 inchesMaximum length of indications in any continuous 12" length of weld: 1" 25 mm

INADEQUATE PENETRATION DUE TO HIGH LOWMaximum length of individual indication of IPD: 2 inches or 50mmMaximum length of indications of IPD in any continuous 12" length of weld: 3" 75 mm

INADEQUATE CROSS PENETRATIONMaximum length of an individual indication of ICP: 2 inches or 50mmMaximum length of indications of ICP in any continuous 12" length of weld: 2" 50 mm

INCOMPLETE FUSIONMaximum length of an individual indication of IF: 1 inch or 25mmMaximum length of IF in 8% of weld: N/A since total weld exceeds 12 inchesMaximum length of indications of IF in any continuous 12" length of weld: 1" 25 mm

INCOMPLETE FUSION DUE TO COLD LAPMaximum length of individual indications of IFD: 2 inches or 50mmMaximum length of IFD in 8% of weld: 127.8128 mmMaximum length of indications of IFD in any continuous 12" length of weld: 2" 25 mm

INTERNAL CONCAVITY Any length of IC is acceptable, provided the density of the radiographic image of the internal concavity does not exceed that of the thinnest adjacent parent material. For areas that exceed the density of thethinnest adjacent parent material, the criteria for burn through are applicable.

BURN - THROUGHMaximum dimension of BT's image : unacceptable if it exceeds that of the thinnest adjacent parent metal.Maximum dimension of BT: 1/4" or 6mmMaximum dimension is unacceptable if: it exceeds the thinner of the nonnal wall thickness joined, and the density

of the BT's image exceeds that of the thinnest adjacent parent material.The sum of the max dimensions of separate BBT's whose image density exceeds that of the thinnest adjacent parentmaterial exceeds 1/2 inch or 13mm in any continuous 12" length of weld or the total weld length(whichever is less).

API - 110420" s/40 - 0.594" Wall

Page 1 of 2

Page 149: NDT Code Book Made Easy

API - 110420" s/40 - 0.594" Wall

SLAG INCLUSIONSElongated slag inclusions (ESI)Maximum length of an ESI: 2 inches or 50mmParallel ESI indications (Wagon Tracks) shall be considered a single indication unless the width of either of them exceed1/32" or 0.8mm. In that event they shall be considered separate indications.Maximum length of ESI indications in any continuous 12" length of weld: 2" 50 mmMaximum width of an individual ESI indication: 1/16" or 1.6mmIsolated slag inclusions (ISI)Maximum length of ISI indications in any continuous 12" length of weld: 1/2" 13 mmMaximum width of an ISI indication: 1/8" or 3mmMaximum length of ESI and ISI in 8% of weld: 127.8128 mm

POROSITY Individual or Scattered Porosity.Maximum size of an individual pore: 1/8" or 3mmThe size of an individual pore exceeds 25% of the thinner of the nonimal wall thickness joined.The distribution of scattered porosity exceeds the concentration permitted in Figures 19 or 20.Cluster Porosity (CP)Maximum diameter of the cluster: 1/2 inch or 13mmMaximum length of CP indications in any continuous 12" length of weweld: 1/2" 13 mmMaximum length of an individual pore within a cluster: 1/16 inch or 2mmHollow Bead Porosity (HB)Maximum length of an individual indication of HB: 1/2 inch or 13mmMaximum length of HB indications in any continuous 12" length of weld: 2" 50 mmMaximum length of HB in 8% of weld: 127.8128 mmNOTE: The weld is unacceptable if individual indications of HB, each greater than 1/4 inch or 6mm in length, are seperated by less than 2 inches or 50 mm.

CRACKSNote: Any crack which is not a shallow crater crack or star crack is unacceptable.Maximum length of shallow crater cracks or star cracks: 5/32 inch or 4mm

UNDERCUTTINGUndercutting adjacent to the cover pass (EU) and Undercutting adjacent to the root pass (IU)Maximum length of EU and IU indications (in any combination) in a 12 inch length of weld: 2" 50 mmMaximum length of EU and IU indications: 10.4833" 266.2758 mm (This value is 1/6 th of the total weld length)

ACCUMULATION OF IMPERFECTIONSMaximum length of AI indications in any continuous 12 inch or 300 mm length of weld: 2" 50 mmMaximum length of AI indications of 8% of weld: 127.8128 mm

RADIOGRAPHIC INFOPipe O.D. in inches: 20.00"Amount of Penetrameters required for each shot: 1 penetrameter 1" from the end of film and 1 penny in the center.Total weld length: 62.9" 1597.6600 mmCassette size to complete weld in most efficient way: 3.5 x 17" 4.5 x 17"Amount of shots to complete weld with 1" on each side of readable film: 58% of weld: 5.032" 127.8128 mmHole penetrameters are adjacent to the weld and Wire penetrameters are parallel to the weld.

Page 2 of 2

Page 150: NDT Code Book Made Easy

PENETRAMETER SELECTIONNote: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Wire: 0.013 Esn. Wire: B5 S/S Hole: 17

F/S Wire: 0.010 Esn. Wire: A1 or B6 F/S Hole: 15Welds with reinforcement: S/S Wire: 0.016 Esn. Wire: B4 S/S Hole: 20

F/S Wire: 0.013 Esn. Wire: B5 F/S Hole: 17Maximum allowable reinforcement: 0.0625"/per sideMaximum reinforcement with DWE/SWV: 0.125" Total of walls + reinforcement: 1.125" 28.5750 mmMaximum reinforcement with DWE/DWV: 0.125" Total of walls + reinforcement: 1.125" 28.5750 mmMaximum reinforcement with SWE/SWV: 0.0625" Total of wall + reinforcement: 0.5625" 14.2875 mm

INADEQUATE PENETRATION WITHOUT HIGH LOWMaximum length of individual indication of IP : 1 inch or 25mmMaximum length of IP in 8% of weld: N/A since total weld exceeds 12 inchesMaximum length of indications in any continuous 12" length of weld: 1" 25 mm

INADEQUATE PENETRATION DUE TO HIGH LOWMaximum length of individual indication of IPD: 2 inches or 50mmMaximum length of indications of IPD in any continuous 12" length of weld: 3" 75 mm

INADEQUATE CROSS PENETRATIONMaximum length of an individual indication of ICP: 2 inches or 50mmMaximum length of indications of ICP in any continuous 12" length of weld: 2" 50 mm

INCOMPLETE FUSIONMaximum length of an individual indication of IF: 1 inch or 25mmMaximum length of IF in 8% of weld: N/A since total weld exceeds 12 inchesMaximum length of indications of IF in any continuous 12" length of weld: 1" 25 mm

INCOMPLETE FUSION DUE TO COLD LAPMaximum length of individual indications of IFD: 2 inches or 50mmMaximum length of IFD in 8% of weld: 127.8128 mmMaximum length of indications of IFD in any continuous 12" length of weld: 2" 25 mm

INTERNAL CONCAVITY Any length of IC is acceptable, provided the density of the radiographic image of the internal concavity does not exceed that of the thinnest adjacent parent material. For areas that exceed the density of thethinnest adjacent parent material, the criteria for burn through are applicable.

BURN - THROUGHMaximum dimension of BT's image : unacceptable if it exceeds that of the thinnest adjacent parent metal.Maximum dimension of BT: 1/4" or 6mmMaximum dimension is unacceptable if: it exceeds the thinner of the nonnal wall thickness joined, and the density

of the BT's image exceeds that of the thinnest adjacent parent material.The sum of the max dimensions of separate BBT's whose image density exceeds that of the thinnest adjacent parentmaterial exceeds 1/2 inch or 13mm in any continuous 12" length of weld or the total weld length(whichever is less).

API - 110420" Extra Strong - 0.500" Wall

Page 1 of 2

Page 151: NDT Code Book Made Easy

API - 110420" Extra Strong - 0.500" Wall

SLAG INCLUSIONSElongated slag inclusions (ESI)Maximum length of an ESI: 2 inches or 50mmParallel ESI indications (Wagon Tracks) shall be considered a single indication unless the width of either of them exceed1/32" or 0.8mm. In that event they shall be considered separate indications.Maximum length of ESI indications in any continuous 12" length of weld: 2" 50 mmMaximum width of an individual ESI indication: 1/16" or 1.6mmIsolated slag inclusions (ISI)Maximum length of ISI indications in any continuous 12" length of weld: 1/2" 13 mmMaximum width of an ISI indication: 1/8" or 3mmMaximum length of ESI and ISI in 8% of weld: 127.8128 mm

POROSITY Individual or Scattered Porosity.Maximum size of an individual pore: 1/8" or 3mmThe size of an individual pore exceeds 25% of the thinner of the nonimal wall thickness joined.The distribution of scattered porosity exceeds the concentration permitted in Figures 19 or 20.Cluster Porosity (CP)Maximum diameter of the cluster: 1/2 inch or 13mmMaximum length of CP indications in any continuous 12" length of weweld: 1/2" 13 mmMaximum length of an individual pore within a cluster: 1/16 inch or 2mmHollow Bead Porosity (HB)Maximum length of an individual indication of HB: 1/2 inch or 13mmMaximum length of HB indications in any continuous 12" length of weld: 2" 50 mmMaximum length of HB in 8% of weld: 127.8128 mmNOTE: The weld is unacceptable if individual indications of HB, each greater than 1/4 inch or 6mm in length, are seperated by less than 2 inches or 50 mm.

CRACKSNote: Any crack which is not a shallow crater crack or star crack is unacceptable.Maximum length of shallow crater cracks or star cracks: 5/32 inch or 4mm

UNDERCUTTINGUndercutting adjacent to the cover pass (EU) and Undercutting adjacent to the root pass (IU)Maximum length of EU and IU indications (in any combination) in a 12 inch length of weld: 2" 50 mmMaximum length of EU and IU indications: 10.4833" 266.2758 mm (This value is 1/6 th of the total weld length)

ACCUMULATION OF IMPERFECTIONSMaximum length of AI indications in any continuous 12 inch or 300 mm length of weld: 2" 50 mmMaximum length of AI indications of 8% of weld: 127.8128 mm

RADIOGRAPHIC INFOPipe O.D. in inches: 20.00"Amount of Penetrameters required for each shot: 1 penetrameter 1" from the end of film and 1 penny in the center.Total weld length: 62.9" 1597.6600 mmCassette size to complete weld in most efficient way: 3.5 x 17" 4.5 x 17"Amount of shots to complete weld with 1" on each side of readable film: 58% of weld: 5.032" 127.8128 mmHole penetrameters are adjacent to the weld and Wire penetrameters are parallel to the weld.

Page 2 of 2

Page 152: NDT Code Book Made Easy

PENETRAMETER SELECTIONNote: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Wire: 0.025 Esn. Wire: B2 S/S Hole: 30

F/S Wire: 0.020 Esn. Wire: B3 F/S Hole: 25Welds with reinforcement: S/S Wire: 0.025 Esn. Wire: B2 S/S Hole: 30

F/S Wire: 0.020 Esn. Wire: B3 F/S Hole: 25Maximum allowable reinforcement: 0.0625"/per sideMaximum reinforcement with DWE/SWV: 0.125" Total of walls + reinforcement: 2.187" 55.5498 mmMaximum reinforcement with DWE/DWV: 0.125" Total of walls + reinforcement: 2.187" 55.5498 mmMaximum reinforcement with SWE/SWV: 0.0625" Total of wall + reinforcement: 1.0935" 27.7749 mm

INADEQUATE PENETRATION WITHOUT HIGH LOWMaximum length of individual indication of IP : 1 inch or 25mmMaximum length of IP in 8% of weld: N/A since total weld exceeds 12 inchesMaximum length of indications in any continuous 12" length of weld: 1" 25 mm

INADEQUATE PENETRATION DUE TO HIGH LOWMaximum length of individual indication of IPD: 2 inches or 50mmMaximum length of indications of IPD in any continuous 12" length of weld: 3" 75 mm

INADEQUATE CROSS PENETRATIONMaximum length of an individual indication of ICP: 2 inches or 50mmMaximum length of indications of ICP in any continuous 12" length of weld: 2" 50 mm

INCOMPLETE FUSIONMaximum length of an individual indication of IF: 1 inch or 25mmMaximum length of IF in 8% of weld: N/A since total weld exceeds 12 inchesMaximum length of indications of IF in any continuous 12" length of weld: 1" 25 mm

INCOMPLETE FUSION DUE TO COLD LAPMaximum length of individual indications of IFD: 2 inches or 50mmMaximum length of IFD in 8% of weld: 127.8128 mmMaximum length of indications of IFD in any continuous 12" length of weld: 2" 25 mm

INTERNAL CONCAVITY Any length of IC is acceptable, provided the density of the radiographic image of the internal concavity does not exceed that of the thinnest adjacent parent material. For areas that exceed the density of thethinnest adjacent parent material, the criteria for burn through are applicable.

BURN - THROUGHMaximum dimension of BT's image : unacceptable if it exceeds that of the thinnest adjacent parent metal.Maximum dimension of BT: 1/4" or 6mmMaximum dimension is unacceptable if: it exceeds the thinner of the nonnal wall thickness joined, and the density

of the BT's image exceeds that of the thinnest adjacent parent material.The sum of the max dimensions of separate BBT's whose image density exceeds that of the thinnest adjacent parentmaterial exceeds 1/2 inch or 13mm in any continuous 12" length of weld or the total weld length(whichever is less).

API - 110420" s/80 - 1.031" Wall

Page 1 of 2

Page 153: NDT Code Book Made Easy

API - 110420" s/80 - 1.031" Wall

SLAG INCLUSIONSElongated slag inclusions (ESI)Maximum length of an ESI: 2 inches or 50mmParallel ESI indications (Wagon Tracks) shall be considered a single indication unless the width of either of them exceed1/32" or 0.8mm. In that event they shall be considered separate indications.Maximum length of ESI indications in any continuous 12" length of weld: 2" 50 mmMaximum width of an individual ESI indication: 1/16" or 1.6mmIsolated slag inclusions (ISI)Maximum length of ISI indications in any continuous 12" length of weld: 1/2" 13 mmMaximum width of an ISI indication: 1/8" or 3mmMaximum length of ESI and ISI in 8% of weld: 127.8128 mm

POROSITY Individual or Scattered Porosity.Maximum size of an individual pore: 1/8" or 3mmThe size of an individual pore exceeds 25% of the thinner of the nonimal wall thickness joined.The distribution of scattered porosity exceeds the concentration permitted in Figures 19 or 20.Cluster Porosity (CP)Maximum diameter of the cluster: 1/2 inch or 13mmMaximum length of CP indications in any continuous 12" length of weweld: 1/2" 13 mmMaximum length of an individual pore within a cluster: 1/16 inch or 2mmHollow Bead Porosity (HB)Maximum length of an individual indication of HB: 1/2 inch or 13mmMaximum length of HB indications in any continuous 12" length of weld: 2" 50 mmMaximum length of HB in 8% of weld: 127.8128 mmNOTE: The weld is unacceptable if individual indications of HB, each greater than 1/4 inch or 6mm in length, are seperated by less than 2 inches or 50 mm.

CRACKSNote: Any crack which is not a shallow crater crack or star crack is unacceptable.Maximum length of shallow crater cracks or star cracks: 5/32 inch or 4mm

UNDERCUTTINGUndercutting adjacent to the cover pass (EU) and Undercutting adjacent to the root pass (IU)Maximum length of EU and IU indications (in any combination) in a 12 inch length of weld: 2" 50 mmMaximum length of EU and IU indications: 10.4833" 266.2758 mm (This value is 1/6 th of the total weld length)

ACCUMULATION OF IMPERFECTIONSMaximum length of AI indications in any continuous 12 inch or 300 mm length of weld: 2" 50 mmMaximum length of AI indications of 8% of weld: 127.8128 mm

RADIOGRAPHIC INFOPipe O.D. in inches: 20.00"Amount of Penetrameters required for each shot: 1 penetrameter 1" from the end of film and 1 penny in the center.Total weld length: 62.9" 1597.6600 mmCassette size to complete weld in most efficient way: 3.5 x 17" 4.5 x 17"Amount of shots to complete weld with 1" on each side of readable film: 58% of weld: 5.032" 127.8128 mmHole penetrameters are adjacent to the weld and Wire penetrameters are parallel to the weld.

Page 2 of 2

Page 154: NDT Code Book Made Easy

PENETRAMETER SELECTIONNote: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Wire: 0.025 Esn. Wire: B2 S/S Hole: 30

F/S Wire: 0.020 Esn. Wire: B3 F/S Hole: 25Welds with reinforcement: S/S Wire: 0.032 Esn. Wire: B1 or C6 S/S Hole: 35

F/S Wire: 0.025 Esn. Wire: B2 F/S Hole: 30Maximum allowable reinforcement: 0.0625"/per sideMaximum reinforcement with DWE/SWV: 0.125" Total of walls + reinforcement: 3.125" 79.3750 mmMaximum reinforcement with DWE/DWV: 0.125" Total of walls + reinforcement: 3.125" 79.3750 mmMaximum reinforcement with SWE/SWV: 0.0625" Total of wall + reinforcement: 1.5625" 39.6875 mm

INADEQUATE PENETRATION WITHOUT HIGH LOWMaximum length of individual indication of IP : 1 inch or 25mmMaximum length of IP in 8% of weld: N/A since total weld exceeds 12 inchesMaximum length of indications in any continuous 12" length of weld: 1" 25 mm

INADEQUATE PENETRATION DUE TO HIGH LOWMaximum length of individual indication of IPD: 2 inches or 50mmMaximum length of indications of IPD in any continuous 12" length of weld: 3" 75 mm

INADEQUATE CROSS PENETRATIONMaximum length of an individual indication of ICP: 2 inches or 50mmMaximum length of indications of ICP in any continuous 12" length of weld: 2" 50 mm

INCOMPLETE FUSIONMaximum length of an individual indication of IF: 1 inch or 25mmMaximum length of IF in 8% of weld: N/A since total weld exceeds 12 inchesMaximum length of indications of IF in any continuous 12" length of weld: 1" 25 mm

INCOMPLETE FUSION DUE TO COLD LAPMaximum length of individual indications of IFD: 2 inches or 50mmMaximum length of IFD in 8% of weld: 127.8128 mmMaximum length of indications of IFD in any continuous 12" length of weld: 2" 25 mm

INTERNAL CONCAVITY Any length of IC is acceptable, provided the density of the radiographic image of the internal concavity does not exceed that of the thinnest adjacent parent material. For areas that exceed the density of thethinnest adjacent parent material, the criteria for burn through are applicable.

BURN - THROUGHMaximum dimension of BT's image : unacceptable if it exceeds that of the thinnest adjacent parent metal.Maximum dimension of BT: 1/4" or 6mmMaximum dimension is unacceptable if: it exceeds the thinner of the nonnal wall thickness joined, and the density

of the BT's image exceeds that of the thinnest adjacent parent material.The sum of the max dimensions of separate BBT's whose image density exceeds that of the thinnest adjacent parentmaterial exceeds 1/2 inch or 13mm in any continuous 12" length of weld or the total weld length(whichever is less).

API - 110420" s/120 - 1.500" Wall

Page 1 of 2

Page 155: NDT Code Book Made Easy

API - 110420" s/120 - 1.500" Wall

SLAG INCLUSIONSElongated slag inclusions (ESI)Maximum length of an ESI: 2 inches or 50mmParallel ESI indications (Wagon Tracks) shall be considered a single indication unless the width of either of them exceed1/32" or 0.8mm. In that event they shall be considered separate indications.Maximum length of ESI indications in any continuous 12" length of weld: 2" 50 mmMaximum width of an individual ESI indication: 1/16" or 1.6mmIsolated slag inclusions (ISI)Maximum length of ISI indications in any continuous 12" length of weld: 1/2" 13 mmMaximum width of an ISI indication: 1/8" or 3mmMaximum length of ESI and ISI in 8% of weld: 127.8128 mm

POROSITY Individual or Scattered Porosity.Maximum size of an individual pore: 1/8" or 3mmThe size of an individual pore exceeds 25% of the thinner of the nonimal wall thickness joined.The distribution of scattered porosity exceeds the concentration permitted in Figures 19 or 20.Cluster Porosity (CP)Maximum diameter of the cluster: 1/2 inch or 13mmMaximum length of CP indications in any continuous 12" length of weweld: 1/2" 13 mmMaximum length of an individual pore within a cluster: 1/16 inch or 2mmHollow Bead Porosity (HB)Maximum length of an individual indication of HB: 1/2 inch or 13mmMaximum length of HB indications in any continuous 12" length of weld: 2" 50 mmMaximum length of HB in 8% of weld: 127.8128 mmNOTE: The weld is unacceptable if individual indications of HB, each greater than 1/4 inch or 6mm in length, are seperated by less than 2 inches or 50 mm.

CRACKSNote: Any crack which is not a shallow crater crack or star crack is unacceptable.Maximum length of shallow crater cracks or star cracks: 5/32 inch or 4mm

UNDERCUTTINGUndercutting adjacent to the cover pass (EU) and Undercutting adjacent to the root pass (IU)Maximum length of EU and IU indications (in any combination) in a 12 inch length of weld: 2" 50 mmMaximum length of EU and IU indications: 10.4833" 266.2758 mm (This value is 1/6 th of the total weld length)

ACCUMULATION OF IMPERFECTIONSMaximum length of AI indications in any continuous 12 inch or 300 mm length of weld: 2" 50 mmMaximum length of AI indications of 8% of weld: 127.8128 mm

RADIOGRAPHIC INFOPipe O.D. in inches: 20.00"Amount of Penetrameters required for each shot: 1 penetrameter 1" from the end of film and 1 penny in the center.Total weld length: 62.9" 1597.6600 mmCassette size to complete weld in most efficient way: 3.5 x 17" 4.5 x 17"Amount of shots to complete weld with 1" on each side of readable film: 58% of weld: 5.032" 127.8128 mmHole penetrameters are adjacent to the weld and Wire penetrameters are parallel to the weld.

Page 2 of 2

Page 156: NDT Code Book Made Easy

PENETRAMETER SELECTIONNote: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Wire: 0.025 Esn. Wire: B2 S/S Hole: 30

F/S Wire: 0.020 Esn. Wire: B3 F/S Hole: 25Welds with reinforcement: S/S Wire: 0.032 Esn. Wire: B1 or C6 S/S Hole: 35

F/S Wire: 0.025 Esn. Wire: B2 F/S Hole: 30Maximum allowable reinforcement: 0.0625"/per sideMaximum reinforcement with DWE/SWV: 0.125" Total of walls + reinforcement: 3.625" 92.0750 mmMaximum reinforcement with DWE/DWV: 0.125" Total of walls + reinforcement: 3.625" 92.0750 mmMaximum reinforcement with SWE/SWV: 0.0625" Total of wall + reinforcement: 1.8125" 46.0375 mm

INADEQUATE PENETRATION WITHOUT HIGH LOWMaximum length of individual indication of IP : 1 inch or 25mmMaximum length of IP in 8% of weld: N/A since total weld exceeds 12 inchesMaximum length of indications in any continuous 12" length of weld: 1" 25 mm

INADEQUATE PENETRATION DUE TO HIGH LOWMaximum length of individual indication of IPD: 2 inches or 50mmMaximum length of indications of IPD in any continuous 12" length of weld: 3" 75 mm

INADEQUATE CROSS PENETRATIONMaximum length of an individual indication of ICP: 2 inches or 50mmMaximum length of indications of ICP in any continuous 12" length of weld: 2" 50 mm

INCOMPLETE FUSIONMaximum length of an individual indication of IF: 1 inch or 25mmMaximum length of IF in 8% of weld: N/A since total weld exceeds 12 inchesMaximum length of indications of IF in any continuous 12" length of weld: 1" 25 mm

INCOMPLETE FUSION DUE TO COLD LAPMaximum length of individual indications of IFD: 2 inches or 50mmMaximum length of IFD in 8% of weld: 127.8128 mmMaximum length of indications of IFD in any continuous 12" length of weld: 2" 25 mm

INTERNAL CONCAVITY Any length of IC is acceptable, provided the density of the radiographic image of the internal concavity does not exceed that of the thinnest adjacent parent material. For areas that exceed the density of thethinnest adjacent parent material, the criteria for burn through are applicable.

BURN - THROUGHMaximum dimension of BT's image : unacceptable if it exceeds that of the thinnest adjacent parent metal.Maximum dimension of BT: 1/4" or 6mmMaximum dimension is unacceptable if: it exceeds the thinner of the nonnal wall thickness joined, and the density

of the BT's image exceeds that of the thinnest adjacent parent material.The sum of the max dimensions of separate BBT's whose image density exceeds that of the thinnest adjacent parentmaterial exceeds 1/2 inch or 13mm in any continuous 12" length of weld or the total weld length(whichever is less).

API - 110420" s/140 - 1.750" Wall

Page 1 of 2

Page 157: NDT Code Book Made Easy

API - 110420" s/140 - 1.750" Wall

SLAG INCLUSIONSElongated slag inclusions (ESI)Maximum length of an ESI: 2 inches or 50mmParallel ESI indications (Wagon Tracks) shall be considered a single indication unless the width of either of them exceed1/32" or 0.8mm. In that event they shall be considered separate indications.Maximum length of ESI indications in any continuous 12" length of weld: 2" 50 mmMaximum width of an individual ESI indication: 1/16" or 1.6mmIsolated slag inclusions (ISI)Maximum length of ISI indications in any continuous 12" length of weld: 1/2" 13 mmMaximum width of an ISI indication: 1/8" or 3mmMaximum length of ESI and ISI in 8% of weld: 127.8128 mm

POROSITY Individual or Scattered Porosity.Maximum size of an individual pore: 1/8" or 3mmThe size of an individual pore exceeds 25% of the thinner of the nonimal wall thickness joined.The distribution of scattered porosity exceeds the concentration permitted in Figures 19 or 20.Cluster Porosity (CP)Maximum diameter of the cluster: 1/2 inch or 13mmMaximum length of CP indications in any continuous 12" length of weweld: 1/2" 13 mmMaximum length of an individual pore within a cluster: 1/16 inch or 2mmHollow Bead Porosity (HB)Maximum length of an individual indication of HB: 1/2 inch or 13mmMaximum length of HB indications in any continuous 12" length of weld: 2" 50 mmMaximum length of HB in 8% of weld: 127.8128 mmNOTE: The weld is unacceptable if individual indications of HB, each greater than 1/4 inch or 6mm in length, are seperated by less than 2 inches or 50 mm.

CRACKSNote: Any crack which is not a shallow crater crack or star crack is unacceptable.Maximum length of shallow crater cracks or star cracks: 5/32 inch or 4mm

UNDERCUTTINGUndercutting adjacent to the cover pass (EU) and Undercutting adjacent to the root pass (IU)Maximum length of EU and IU indications (in any combination) in a 12 inch length of weld: 2" 50 mmMaximum length of EU and IU indications: 10.4833" 266.2758 mm (This value is 1/6 th of the total weld length)

ACCUMULATION OF IMPERFECTIONSMaximum length of AI indications in any continuous 12 inch or 300 mm length of weld: 2" 50 mmMaximum length of AI indications of 8% of weld: 127.8128 mm

RADIOGRAPHIC INFOPipe O.D. in inches: 20.00"Amount of Penetrameters required for each shot: 1 penetrameter 1" from the end of film and 1 penny in the center.Total weld length: 62.9" 1597.6600 mmCassette size to complete weld in most efficient way: 3.5 x 17" 4.5 x 17"Amount of shots to complete weld with 1" on each side of readable film: 68% of weld: 5.032" 127.8128 mmHole penetrameters are adjacent to the weld and Wire penetrameters are parallel to the weld.

Page 2 of 2

Page 158: NDT Code Book Made Easy

PENETRAMETER SELECTIONNote: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Wire: 0.032 Esn. Wire: B1 or C6 S/S Hole: 35

F/S Wire: 0.025 Esn. Wire: B2 F/S Hole: 30Welds with reinforcement: S/S Wire: 0.040 Esn. Wire: C5 S/S Hole: 40

F/S Wire: 0.032 Esn. Wire: B1 or C6 F/S Hole: 35Maximum allowable reinforcement: 0.0625"/per sideMaximum reinforcement with DWE/SWV: 0.125" Total of walls + reinforcement: 4.063" 103.2002 mmMaximum reinforcement with DWE/DWV: 0.125" Total of walls + reinforcement: 4.063" 103.2002 mmMaximum reinforcement with SWE/SWV: 0.0625" Total of wall + reinforcement: 2.0315" 51.6001 mm

INADEQUATE PENETRATION WITHOUT HIGH LOWMaximum length of individual indication of IP : 1 inch or 25mmMaximum length of IP in 8% of weld: N/A since total weld exceeds 12 inchesMaximum length of indications in any continuous 12" length of weld: 1" 25 mm

INADEQUATE PENETRATION DUE TO HIGH LOWMaximum length of individual indication of IPD: 2 inches or 50mmMaximum length of indications of IPD in any continuous 12" length of weld: 3" 75 mm

INADEQUATE CROSS PENETRATIONMaximum length of an individual indication of ICP: 2 inches or 50mmMaximum length of indications of ICP in any continuous 12" length of weld: 2" 50 mm

INCOMPLETE FUSIONMaximum length of an individual indication of IF: 1 inch or 25mmMaximum length of IF in 8% of weld: N/A since total weld exceeds 12 inchesMaximum length of indications of IF in any continuous 12" length of weld: 1" 25 mm

INCOMPLETE FUSION DUE TO COLD LAPMaximum length of individual indications of IFD: 2 inches or 50mmMaximum length of IFD in 8% of weld: 127.8128 mmMaximum length of indications of IFD in any continuous 12" length of weld: 2" 25 mm

INTERNAL CONCAVITY Any length of IC is acceptable, provided the density of the radiographic image of the internal concavity does not exceed that of the thinnest adjacent parent material. For areas that exceed the density of thethinnest adjacent parent material, the criteria for burn through are applicable.

BURN - THROUGHMaximum dimension of BT's image : unacceptable if it exceeds that of the thinnest adjacent parent metal.Maximum dimension of BT: 1/4" or 6mmMaximum dimension is unacceptable if: it exceeds the thinner of the nonnal wall thickness joined, and the density

of the BT's image exceeds that of the thinnest adjacent parent material.The sum of the max dimensions of separate BBT's whose image density exceeds that of the thinnest adjacent parentmaterial exceeds 1/2 inch or 13mm in any continuous 12" length of weld or the total weld length(whichever is less).

API - 110420" s/160 - 1.969" Wall

Page 1 of 2

Page 159: NDT Code Book Made Easy

API - 110420" s/160 - 1.969" Wall

SLAG INCLUSIONSElongated slag inclusions (ESI)Maximum length of an ESI: 2 inches or 50mmParallel ESI indications (Wagon Tracks) shall be considered a single indication unless the width of either of them exceed1/32" or 0.8mm. In that event they shall be considered separate indications.Maximum length of ESI indications in any continuous 12" length of weld: 2" 50 mmMaximum width of an individual ESI indication: 1/16" or 1.6mmIsolated slag inclusions (ISI)Maximum length of ISI indications in any continuous 12" length of weld: 1/2" 13 mmMaximum width of an ISI indication: 1/8" or 3mmMaximum length of ESI and ISI in 8% of weld: 127.8128 mm

POROSITY Individual or Scattered Porosity.Maximum size of an individual pore: 1/8" or 3mmThe size of an individual pore exceeds 25% of the thinner of the nonimal wall thickness joined.The distribution of scattered porosity exceeds the concentration permitted in Figures 19 or 20.Cluster Porosity (CP)Maximum diameter of the cluster: 1/2 inch or 13mmMaximum length of CP indications in any continuous 12" length of weweld: 1/2" 13 mmMaximum length of an individual pore within a cluster: 1/16 inch or 2mmHollow Bead Porosity (HB)Maximum length of an individual indication of HB: 1/2 inch or 13mmMaximum length of HB indications in any continuous 12" length of weld: 2" 50 mmMaximum length of HB in 8% of weld: 127.8128 mmNOTE: The weld is unacceptable if individual indications of HB, each greater than 1/4 inch or 6mm in length, are seperated by less than 2 inches or 50 mm.

CRACKSNote: Any crack which is not a shallow crater crack or star crack is unacceptable.Maximum length of shallow crater cracks or star cracks: 5/32 inch or 4mm

UNDERCUTTINGUndercutting adjacent to the cover pass (EU) and Undercutting adjacent to the root pass (IU)Maximum length of EU and IU indications (in any combination) in a 12 inch length of weld: 2" 50 mmMaximum length of EU and IU indications: 10.4833" 266.2758 mm (This value is 1/6 th of the total weld length)

ACCUMULATION OF IMPERFECTIONSMaximum length of AI indications in any continuous 12 inch or 300 mm length of weld: 2" 50 mmMaximum length of AI indications of 8% of weld: 127.8128 mm

RADIOGRAPHIC INFOPipe O.D. in inches: 20.00"Amount of Penetrameters required for each shot: 1 penetrameter 1" from the end of film and 1 penny in the center.Total weld length: 62.9" 1597.6600 mmCassette size to complete weld in most efficient way: 3.5 x 17" 4.5 x 17"Amount of shots to complete weld with 1" on each side of readable film: 68% of weld: 5.032" 127.8128 mmHole penetrameters are adjacent to the weld and Wire penetrameters are parallel to the weld.

Page 2 of 2

Page 160: NDT Code Book Made Easy

PENETRAMETER SELECTIONNote: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Wire: 0.008 Esn. Wire: A2 S/S Hole: 12

F/S Wire: 0.006 Esn. Wire: A3 F/S Hole: 10Welds with reinforcement: S/S Wire: 0.010 Esn. Wire: A1 or B6 S/S Hole: 15

F/S Wire: 0.008 Esn. Wire: A2 F/S Hole: 12Maximum allowable reinforcement: 0.0625"/per sideMaximum reinforcement with DWE/SWV: 0.125" Total of walls + reinforcement: 0.625" 15.8750 mmMaximum reinforcement with DWE/DWV: 0.125" Total of walls + reinforcement: 0.625" 15.8750 mmMaximum reinforcement with SWE/SWV: 0.0625" Total of wall + reinforcement: 0.3125" 7.9375 mm

INADEQUATE PENETRATION WITHOUT HIGH LOWMaximum length of individual indication of IP : 1 inch or 25mmMaximum length of IP in 8% of weld: N/A since total weld exceeds 12 inchesMaximum length of indications in any continuous 12" length of weld: 1" 25 mm

INADEQUATE PENETRATION DUE TO HIGH LOWMaximum length of individual indication of IPD: 2 inches or 50mmMaximum length of indications of IPD in any continuous 12" length of weld: 3" 75 mm

INADEQUATE CROSS PENETRATIONMaximum length of an individual indication of ICP: 2 inches or 50mmMaximum length of indications of ICP in any continuous 12" length of weld: 2" 50 mm

INCOMPLETE FUSIONMaximum length of an individual indication of IF: 1 inch or 25mmMaximum length of IF in 8% of weld: N/A since total weld exceeds 12 inchesMaximum length of indications of IF in any continuous 12" length of weld: 1" 25 mm

INCOMPLETE FUSION DUE TO COLD LAPMaximum length of individual indications of IFD: 2 inches or 50mmMaximum length of IFD in 8% of weld: 140.5941 mmMaximum length of indications of IFD in any continuous 12" length of weld: 2" 25 mm

INTERNAL CONCAVITY Any length of IC is acceptable, provided the density of the radiographic image of the internal concavity does not exceed that of the thinnest adjacent parent material. For areas that exceed the density of thethinnest adjacent parent material, the criteria for burn through are applicable.

BURN - THROUGHMaximum dimension of BT's image : unacceptable if it exceeds that of the thinnest adjacent parent metal.Maximum dimension of BT: 1/4" or 6mmMaximum dimension is unacceptable if: it exceeds the thinner of the nonnal wall thickness joined, and the density

of the BT's image exceeds that of the thinnest adjacent parent material.The sum of the max dimensions of separate BBT's whose image density exceeds that of the thinnest adjacent parentmaterial exceeds 1/2 inch or 13mm in any continuous 12" length of weld or the total weld length(whichever is less).

API - 110422" s/10 - 0.250" Wall

Page 1 of 2

Page 161: NDT Code Book Made Easy

API - 110422" s/10 - 0.250" Wall

SLAG INCLUSIONSElongated slag inclusions (ESI)Maximum length of an ESI: 2 inches or 50mmParallel ESI indications (Wagon Tracks) shall be considered a single indication unless the width of either of them exceed1/32" or 0.8mm. In that event they shall be considered separate indications.Maximum length of ESI indications in any continuous 12" length of weld: 2" 50 mmMaximum width of an individual ESI indication: 1/16" or 1.6mmIsolated slag inclusions (ISI)Maximum length of ISI indications in any continuous 12" length of weld: 1/2" 13 mmMaximum width of an ISI indication: 1/8" or 3mmMaximum length of ESI and ISI in 8% of weld: 140.5941 mm

POROSITY Individual or Scattered Porosity.Maximum size of an individual pore: 1/8" or 3mmThe size of an individual pore exceeds 25% of the thinner of the nonimal wall thickness joined.The distribution of scattered porosity exceeds the concentration permitted in Figures 19 or 20.Cluster Porosity (CP)Maximum diameter of the cluster: 1/2 inch or 13mmMaximum length of CP indications in any continuous 12" length of weweld: 1/2" 13 mmMaximum length of an individual pore within a cluster: 1/16 inch or 2mmHollow Bead Porosity (HB)Maximum length of an individual indication of HB: 1/2 inch or 13mmMaximum length of HB indications in any continuous 12" length of weld: 2" 50 mmMaximum length of HB in 8% of weld: 140.5941 mmNOTE: The weld is unacceptable if individual indications of HB, each greater than 1/4 inch or 6mm in length, are seperated by less than 2 inches or 50 mm.

CRACKSNote: Any crack which is not a shallow crater crack or star crack is unacceptable.Maximum length of shallow crater cracks or star cracks: 5/32 inch or 4mm

UNDERCUTTINGUndercutting adjacent to the cover pass (EU) and Undercutting adjacent to the root pass (IU)Maximum length of EU and IU indications (in any combination) in a 12 inch length of weld: 2" 50 mmMaximum length of EU and IU indications: 11.532" 292.9128 mm (This value is 1/6 th of the total weld length)

ACCUMULATION OF IMPERFECTIONSMaximum length of AI indications in any continuous 12 inch or 300 mm length of weld: 2" 50 mmMaximum length of AI indications of 8% of weld: 140.5941 mm

RADIOGRAPHIC INFOPipe O.D. in inches: 22.00"Amount of Penetrameters required for each shot: 1 penetrameter 1" from the end of film and 1 penny in the center.Total weld length: 69.19" 1757.4260 mmCassette size to complete weld in most efficient way: 3.5 x 17" 4.5 x 17"Amount of shots to complete weld with 1" on each side of readable film: 58% of weld: 5.5352" 140.5941 mmHole penetrameters are adjacent to the weld and Wire penetrameters are parallel to the weld.

Page 2 of 2

Page 162: NDT Code Book Made Easy

PENETRAMETER SELECTIONNote: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Wire: 0.010 Esn. Wire: A1 or B6 S/S Hole: 15

F/S Wire: 0.008 Esn. Wire: A2 F/S Hole: 12Welds with reinforcement: S/S Wire: 0.013 Esn. Wire: B5 S/S Hole: 17

F/S Wire: 0.010 Esn. Wire: A1 or B6 F/S Hole: 15Maximum allowable reinforcement: 0.0625"/per sideMaximum reinforcement with DWE/SWV: 0.125" Total of walls + reinforcement: 0.875" 22.2250 mmMaximum reinforcement with DWE/DWV: 0.125" Total of walls + reinforcement: 0.875" 22.2250 mmMaximum reinforcement with SWE/SWV: 0.0625" Total of wall + reinforcement: 0.4375" 11.1125 mm

INADEQUATE PENETRATION WITHOUT HIGH LOWMaximum length of individual indication of IP : 1 inch or 25mmMaximum length of IP in 8% of weld: N/A since total weld exceeds 12 inchesMaximum length of indications in any continuous 12" length of weld: 1" 25 mm

INADEQUATE PENETRATION DUE TO HIGH LOWMaximum length of individual indication of IPD: 2 inches or 50mmMaximum length of indications of IPD in any continuous 12" length of weld: 3" 75 mm

INADEQUATE CROSS PENETRATIONMaximum length of an individual indication of ICP: 2 inches or 50mmMaximum length of indications of ICP in any continuous 12" length of weld: 2" 50 mm

INCOMPLETE FUSIONMaximum length of an individual indication of IF: 1 inch or 25mmMaximum length of IF in 8% of weld: N/A since total weld exceeds 12 inchesMaximum length of indications of IF in any continuous 12" length of weld: 1" 25 mm

INCOMPLETE FUSION DUE TO COLD LAPMaximum length of individual indications of IFD: 2 inches or 50mmMaximum length of IFD in 8% of weld: 140.5941 mmMaximum length of indications of IFD in any continuous 12" length of weld: 2" 25 mm

INTERNAL CONCAVITY Any length of IC is acceptable, provided the density of the radiographic image of the internal concavity does not exceed that of the thinnest adjacent parent material. For areas that exceed the density of thethinnest adjacent parent material, the criteria for burn through are applicable.

BURN - THROUGHMaximum dimension of BT's image : unacceptable if it exceeds that of the thinnest adjacent parent metal.Maximum dimension of BT: 1/4" or 6mmMaximum dimension is unacceptable if: it exceeds the thinner of the nonnal wall thickness joined, and the density

of the BT's image exceeds that of the thinnest adjacent parent material.The sum of the max dimensions of separate BBT's whose image density exceeds that of the thinnest adjacent parentmaterial exceeds 1/2 inch or 13mm in any continuous 12" length of weld or the total weld length(whichever is less).

API - 110422" Standard - 0.375" Wall

Page 1 of 2

Page 163: NDT Code Book Made Easy

API - 110422" Standard - 0.375" Wall

SLAG INCLUSIONSElongated slag inclusions (ESI)Maximum length of an ESI: 2 inches or 50mmParallel ESI indications (Wagon Tracks) shall be considered a single indication unless the width of either of them exceed1/32" or 0.8mm. In that event they shall be considered separate indications.Maximum length of ESI indications in any continuous 12" length of weld: 2" 50 mmMaximum width of an individual ESI indication: 1/16" or 1.6mmIsolated slag inclusions (ISI)Maximum length of ISI indications in any continuous 12" length of weld: 1/2" 13 mmMaximum width of an ISI indication: 1/8" or 3mmMaximum length of ESI and ISI in 8% of weld: 140.5941 mm

POROSITY Individual or Scattered Porosity.Maximum size of an individual pore: 1/8" or 3mmThe size of an individual pore exceeds 25% of the thinner of the nonimal wall thickness joined.The distribution of scattered porosity exceeds the concentration permitted in Figures 19 or 20.Cluster Porosity (CP)Maximum diameter of the cluster: 1/2 inch or 13mmMaximum length of CP indications in any continuous 12" length of weweld: 1/2" 13 mmMaximum length of an individual pore within a cluster: 1/16 inch or 2mmHollow Bead Porosity (HB)Maximum length of an individual indication of HB: 1/2 inch or 13mmMaximum length of HB indications in any continuous 12" length of weld: 2" 50 mmMaximum length of HB in 8% of weld: 140.5941 mmNOTE: The weld is unacceptable if individual indications of HB, each greater than 1/4 inch or 6mm in length, are seperated by less than 2 inches or 50 mm.

CRACKSNote: Any crack which is not a shallow crater crack or star crack is unacceptable.Maximum length of shallow crater cracks or star cracks: 5/32 inch or 4mm

UNDERCUTTINGUndercutting adjacent to the cover pass (EU) and Undercutting adjacent to the root pass (IU)Maximum length of EU and IU indications (in any combination) in a 12 inch length of weld: 2" 50 mmMaximum length of EU and IU indications: 11.532" 292.9128 mm (This value is 1/6 th of the total weld length)

ACCUMULATION OF IMPERFECTIONSMaximum length of AI indications in any continuous 12 inch or 300 mm length of weld: 2" 50 mmMaximum length of AI indications of 8% of weld: 140.5941 mm

RADIOGRAPHIC INFOPipe O.D. in inches: 22.00"Amount of Penetrameters required for each shot: 1 penetrameter 1" from the end of film and 1 penny in the center.Total weld length: 69.19" 1757.4260 mmCassette size to complete weld in most efficient way: 3.5 x 17" 4.5 x 17"Amount of shots to complete weld with 1" on each side of readable film: 58% of weld: 5.5352" 140.5941 mmHole penetrameters are adjacent to the weld and Wire penetrameters are parallel to the weld.

Page 2 of 2

Page 164: NDT Code Book Made Easy

PENETRAMETER SELECTIONNote: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Wire: 0.013 Esn. Wire: B5 S/S Hole: 17

F/S Wire: 0.010 Esn. Wire: A1 or B6 F/S Hole: 15Welds with reinforcement: S/S Wire: 0.016 Esn. Wire: B4 S/S Hole: 20

F/S Wire: 0.013 Esn. Wire: B5 F/S Hole: 17Maximum allowable reinforcement: 0.0625"/per sideMaximum reinforcement with DWE/SWV: 0.125" Total of walls + reinforcement: 1.125" 28.5750 mmMaximum reinforcement with DWE/DWV: 0.125" Total of walls + reinforcement: 1.125" 28.5750 mmMaximum reinforcement with SWE/SWV: 0.0625" Total of wall + reinforcement: 0.5625" 14.2875 mm

INADEQUATE PENETRATION WITHOUT HIGH LOWMaximum length of individual indication of IP : 1 inch or 25mmMaximum length of IP in 8% of weld: N/A since total weld exceeds 12 inchesMaximum length of indications in any continuous 12" length of weld: 1" 25 mm

INADEQUATE PENETRATION DUE TO HIGH LOWMaximum length of individual indication of IPD: 2 inches or 50mmMaximum length of indications of IPD in any continuous 12" length of weld: 3" 75 mm

INADEQUATE CROSS PENETRATIONMaximum length of an individual indication of ICP: 2 inches or 50mmMaximum length of indications of ICP in any continuous 12" length of weld: 2" 50 mm

INCOMPLETE FUSIONMaximum length of an individual indication of IF: 1 inch or 25mmMaximum length of IF in 8% of weld: N/A since total weld exceeds 12 inchesMaximum length of indications of IF in any continuous 12" length of weld: 1" 25 mm

INCOMPLETE FUSION DUE TO COLD LAPMaximum length of individual indications of IFD: 2 inches or 50mmMaximum length of IFD in 8% of weld: 140.5941 mmMaximum length of indications of IFD in any continuous 12" length of weld: 2" 25 mm

INTERNAL CONCAVITY Any length of IC is acceptable, provided the density of the radiographic image of the internal concavity does not exceed that of the thinnest adjacent parent material. For areas that exceed the density of thethinnest adjacent parent material, the criteria for burn through are applicable.

BURN - THROUGHMaximum dimension of BT's image : unacceptable if it exceeds that of the thinnest adjacent parent metal.Maximum dimension of BT: 1/4" or 6mmMaximum dimension is unacceptable if: it exceeds the thinner of the nonnal wall thickness joined, and the density

of the BT's image exceeds that of the thinnest adjacent parent material.The sum of the max dimensions of separate BBT's whose image density exceeds that of the thinnest adjacent parentmaterial exceeds 1/2 inch or 13mm in any continuous 12" length of weld or the total weld length(whichever is less).

API - 110422" Extra Strong - 0.500" Wall

Page 1 of 2

Page 165: NDT Code Book Made Easy

API - 110422" Extra Strong - 0.500" Wall

SLAG INCLUSIONSElongated slag inclusions (ESI)Maximum length of an ESI: 2 inches or 50mmParallel ESI indications (Wagon Tracks) shall be considered a single indication unless the width of either of them exceed1/32" or 0.8mm. In that event they shall be considered separate indications.Maximum length of ESI indications in any continuous 12" length of weld: 2" 50 mmMaximum width of an individual ESI indication: 1/16" or 1.6mmIsolated slag inclusions (ISI)Maximum length of ISI indications in any continuous 12" length of weld: 1/2" 13 mmMaximum width of an ISI indication: 1/8" or 3mmMaximum length of ESI and ISI in 8% of weld: 140.5941 mm

POROSITY Individual or Scattered Porosity.Maximum size of an individual pore: 1/8" or 3mmThe size of an individual pore exceeds 25% of the thinner of the nonimal wall thickness joined.The distribution of scattered porosity exceeds the concentration permitted in Figures 19 or 20.Cluster Porosity (CP)Maximum diameter of the cluster: 1/2 inch or 13mmMaximum length of CP indications in any continuous 12" length of weweld: 1/2" 13 mmMaximum length of an individual pore within a cluster: 1/16 inch or 2mmHollow Bead Porosity (HB)Maximum length of an individual indication of HB: 1/2 inch or 13mmMaximum length of HB indications in any continuous 12" length of weld: 2" 50 mmMaximum length of HB in 8% of weld: 140.5941 mmNOTE: The weld is unacceptable if individual indications of HB, each greater than 1/4 inch or 6mm in length, are seperated by less than 2 inches or 50 mm.

CRACKSNote: Any crack which is not a shallow crater crack or star crack is unacceptable.Maximum length of shallow crater cracks or star cracks: 5/32 inch or 4mm

UNDERCUTTINGUndercutting adjacent to the cover pass (EU) and Undercutting adjacent to the root pass (IU)Maximum length of EU and IU indications (in any combination) in a 12 inch length of weld: 2" 50 mmMaximum length of EU and IU indications: 11.532" 292.9128 mm (This value is 1/6 th of the total weld length)

ACCUMULATION OF IMPERFECTIONSMaximum length of AI indications in any continuous 12 inch or 300 mm length of weld: 2" 50 mmMaximum length of AI indications of 8% of weld: 140.5941 mm

RADIOGRAPHIC INFOPipe O.D. in inches: 22.00"Amount of Penetrameters required for each shot: 1 penetrameter 1" from the end of film and 1 penny in the center.Total weld length: 69.19" 1757.4260 mmCassette size to complete weld in most efficient way: 3.5 x 17" 4.5 x 17"Amount of shots to complete weld with 1" on each side of readable film: 58% of weld: 5.5352" 140.5941 mmHole penetrameters are adjacent to the weld and Wire penetrameters are parallel to the weld.

Page 2 of 2

Page 166: NDT Code Book Made Easy

PENETRAMETER SELECTIONNote: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Wire: 0.025 Esn. Wire: B2 S/S Hole: 30

F/S Wire: 0.020 Esn. Wire: B3 F/S Hole: 25Welds with reinforcement: S/S Wire: 0.025 Esn. Wire: B2 S/S Hole: 30

F/S Wire: 0.020 Esn. Wire: B3 F/S Hole: 25Maximum allowable reinforcement: 0.0625"/per sideMaximum reinforcement with DWE/SWV: 0.125" Total of walls + reinforcement: 2.375" 60.3250 mmMaximum reinforcement with DWE/DWV: 0.125" Total of walls + reinforcement: 2.375" 60.3250 mmMaximum reinforcement with SWE/SWV: 0.0625" Total of wall + reinforcement: 1.1875" 30.1625 mm

INADEQUATE PENETRATION WITHOUT HIGH LOWMaximum length of individual indication of IP : 1 inch or 25mmMaximum length of IP in 8% of weld: N/A since total weld exceeds 12 inchesMaximum length of indications in any continuous 12" length of weld: 1" 25 mm

INADEQUATE PENETRATION DUE TO HIGH LOWMaximum length of individual indication of IPD: 2 inches or 50mmMaximum length of indications of IPD in any continuous 12" length of weld: 3" 75 mm

INADEQUATE CROSS PENETRATIONMaximum length of an individual indication of ICP: 2 inches or 50mmMaximum length of indications of ICP in any continuous 12" length of weld: 2" 50 mm

INCOMPLETE FUSIONMaximum length of an individual indication of IF: 1 inch or 25mmMaximum length of IF in 8% of weld: N/A since total weld exceeds 12 inchesMaximum length of indications of IF in any continuous 12" length of weld: 1" 25 mm

INCOMPLETE FUSION DUE TO COLD LAPMaximum length of individual indications of IFD: 2 inches or 50mmMaximum length of IFD in 8% of weld: 140.5941 mmMaximum length of indications of IFD in any continuous 12" length of weld: 2" 25 mm

INTERNAL CONCAVITY Any length of IC is acceptable, provided the density of the radiographic image of the internal concavity does not exceed that of the thinnest adjacent parent material. For areas that exceed the density of thethinnest adjacent parent material, the criteria for burn through are applicable.

BURN - THROUGHMaximum dimension of BT's image : unacceptable if it exceeds that of the thinnest adjacent parent metal.Maximum dimension of BT: 1/4" or 6mmMaximum dimension is unacceptable if: it exceeds the thinner of the nonnal wall thickness joined, and the density

of the BT's image exceeds that of the thinnest adjacent parent material.The sum of the max dimensions of separate BBT's whose image density exceeds that of the thinnest adjacent parentmaterial exceeds 1/2 inch or 13mm in any continuous 12" length of weld or the total weld length(whichever is less).

API - 110422" s/80 - 1.125" Wall

Page 1 of 2

Page 167: NDT Code Book Made Easy

API - 110422" s/80 - 1.125" Wall

SLAG INCLUSIONSElongated slag inclusions (ESI)Maximum length of an ESI: 2 inches or 50mmParallel ESI indications (Wagon Tracks) shall be considered a single indication unless the width of either of them exceed1/32" or 0.8mm. In that event they shall be considered separate indications.Maximum length of ESI indications in any continuous 12" length of weld: 2" 50 mmMaximum width of an individual ESI indication: 1/16" or 1.6mmIsolated slag inclusions (ISI)Maximum length of ISI indications in any continuous 12" length of weld: 1/2" 13 mmMaximum width of an ISI indication: 1/8" or 3mmMaximum length of ESI and ISI in 8% of weld: 140.5941 mm

POROSITY Individual or Scattered Porosity.Maximum size of an individual pore: 1/8" or 3mmThe size of an individual pore exceeds 25% of the thinner of the nonimal wall thickness joined.The distribution of scattered porosity exceeds the concentration permitted in Figures 19 or 20.Cluster Porosity (CP)Maximum diameter of the cluster: 1/2 inch or 13mmMaximum length of CP indications in any continuous 12" length of weweld: 1/2" 13 mmMaximum length of an individual pore within a cluster: 1/16 inch or 2mmHollow Bead Porosity (HB)Maximum length of an individual indication of HB: 1/2 inch or 13mmMaximum length of HB indications in any continuous 12" length of weld: 2" 50 mmMaximum length of HB in 8% of weld: 140.5941 mmNOTE: The weld is unacceptable if individual indications of HB, each greater than 1/4 inch or 6mm in length, are seperated by less than 2 inches or 50 mm.

CRACKSNote: Any crack which is not a shallow crater crack or star crack is unacceptable.Maximum length of shallow crater cracks or star cracks: 5/32 inch or 4mm

UNDERCUTTINGUndercutting adjacent to the cover pass (EU) and Undercutting adjacent to the root pass (IU)Maximum length of EU and IU indications (in any combination) in a 12 inch length of weld: 2" 50 mmMaximum length of EU and IU indications: 11.532" 292.9128 mm (This value is 1/6 th of the total weld length)

ACCUMULATION OF IMPERFECTIONSMaximum length of AI indications in any continuous 12 inch or 300 mm length of weld: 2" 50 mmMaximum length of AI indications of 8% of weld: 140.5941 mm

RADIOGRAPHIC INFOPipe O.D. in inches: 22.00"Amount of Penetrameters required for each shot: 1 penetrameter 1" from the end of film and 1 penny in the center.Total weld length: 69.19" 1757.4260 mmCassette size to complete weld in most efficient way: 3.5 x 17" 4.5 x 17"Amount of shots to complete weld with 1" on each side of readable film: 58% of weld: 5.5352" 140.5941 mmHole penetrameters are adjacent to the weld and Wire penetrameters are parallel to the weld.

Page 2 of 2

Page 168: NDT Code Book Made Easy

PENETRAMETER SELECTIONNote: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Wire: 0.032 Esn. Wire: B1 or C6 S/S Hole: 35

F/S Wire: 0.025 Esn. Wire: B2 F/S Hole: 30Welds with reinforcement: S/S Wire: 0.040 Esn. Wire: C5 S/S Hole: 40

F/S Wire: 0.032 Esn. Wire: B1 or C6 F/S Hole: 35Maximum allowable reinforcement: 0.0625"/per sideMaximum reinforcement with DWE/SWV: 0.125" Total of walls + reinforcement: 3.375" 85.7250 mmMaximum reinforcement with DWE/DWV: 0.125" Total of walls + reinforcement: 3.375" 85.7250 mmMaximum reinforcement with SWE/SWV: 0.0625" Total of wall + reinforcement: 1.6875" 42.8625 mm

INADEQUATE PENETRATION WITHOUT HIGH LOWMaximum length of individual indication of IP : 1 inch or 25mmMaximum length of IP in 8% of weld: N/A since total weld exceeds 12 inchesMaximum length of indications in any continuous 12" length of weld: 1" 25 mm

INADEQUATE PENETRATION DUE TO HIGH LOWMaximum length of individual indication of IPD: 2 inches or 50mmMaximum length of indications of IPD in any continuous 12" length of weld: 3" 75 mm

INADEQUATE CROSS PENETRATIONMaximum length of an individual indication of ICP: 2 inches or 50mmMaximum length of indications of ICP in any continuous 12" length of weld: 2" 50 mm

INCOMPLETE FUSIONMaximum length of an individual indication of IF: 1 inch or 25mmMaximum length of IF in 8% of weld: N/A since total weld exceeds 12 inchesMaximum length of indications of IF in any continuous 12" length of weld: 1" 25 mm

INCOMPLETE FUSION DUE TO COLD LAPMaximum length of individual indications of IFD: 2 inches or 50mmMaximum length of IFD in 8% of weld: 140.5941 mmMaximum length of indications of IFD in any continuous 12" length of weld: 2" 25 mm

INTERNAL CONCAVITY Any length of IC is acceptable, provided the density of the radiographic image of the internal concavity does not exceed that of the thinnest adjacent parent material. For areas that exceed the density of thethinnest adjacent parent material, the criteria for burn through are applicable.

BURN - THROUGHMaximum dimension of BT's image : unacceptable if it exceeds that of the thinnest adjacent parent metal.Maximum dimension of BT: 1/4" or 6mmMaximum dimension is unacceptable if: it exceeds the thinner of the nonnal wall thickness joined, and the density

of the BT's image exceeds that of the thinnest adjacent parent material.The sum of the max dimensions of separate BBT's whose image density exceeds that of the thinnest adjacent parentmaterial exceeds 1/2 inch or 13mm in any continuous 12" length of weld or the total weld length(whichever is less).

API - 110422" s/120 - 1.625" Wall

Page 1 of 2

Page 169: NDT Code Book Made Easy

API - 110422" s/120 - 1.625" Wall

SLAG INCLUSIONSElongated slag inclusions (ESI)Maximum length of an ESI: 2 inches or 50mmParallel ESI indications (Wagon Tracks) shall be considered a single indication unless the width of either of them exceed1/32" or 0.8mm. In that event they shall be considered separate indications.Maximum length of ESI indications in any continuous 12" length of weld: 2" 50 mmMaximum width of an individual ESI indication: 1/16" or 1.6mmIsolated slag inclusions (ISI)Maximum length of ISI indications in any continuous 12" length of weld: 1/2" 13 mmMaximum width of an ISI indication: 1/8" or 3mmMaximum length of ESI and ISI in 8% of weld: 140.5941 mm

POROSITY Individual or Scattered Porosity.Maximum size of an individual pore: 1/8" or 3mmThe size of an individual pore exceeds 25% of the thinner of the nonimal wall thickness joined.The distribution of scattered porosity exceeds the concentration permitted in Figures 19 or 20.Cluster Porosity (CP)Maximum diameter of the cluster: 1/2 inch or 13mmMaximum length of CP indications in any continuous 12" length of weweld: 1/2" 13 mmMaximum length of an individual pore within a cluster: 1/16 inch or 2mmHollow Bead Porosity (HB)Maximum length of an individual indication of HB: 1/2 inch or 13mmMaximum length of HB indications in any continuous 12" length of weld: 2" 50 mmMaximum length of HB in 8% of weld: 140.5941 mmNOTE: The weld is unacceptable if individual indications of HB, each greater than 1/4 inch or 6mm in length, are seperated by less than 2 inches or 50 mm.

CRACKSNote: Any crack which is not a shallow crater crack or star crack is unacceptable.Maximum length of shallow crater cracks or star cracks: 5/32 inch or 4mm

UNDERCUTTINGUndercutting adjacent to the cover pass (EU) and Undercutting adjacent to the root pass (IU)Maximum length of EU and IU indications (in any combination) in a 12 inch length of weld: 2" 50 mmMaximum length of EU and IU indications: 11.532" 292.9128 mm (This value is 1/6 th of the total weld length)

ACCUMULATION OF IMPERFECTIONSMaximum length of AI indications in any continuous 12 inch or 300 mm length of weld: 2" 50 mmMaximum length of AI indications of 8% of weld: 140.5941 mm

RADIOGRAPHIC INFOPipe O.D. in inches: 22.00"Amount of Penetrameters required for each shot: 1 penetrameter 1" from the end of film and 1 penny in the center.Total weld length: 69.19" 1757.4260 mmCassette size to complete weld in most efficient way: 3.5 x 17" 4.5 x 17"Amount of shots to complete weld with 1" on each side of readable film: 68% of weld: 5.5352" 140.5941 mmHole penetrameters are adjacent to the weld and Wire penetrameters are parallel to the weld.

Page 2 of 2

Page 170: NDT Code Book Made Easy

PENETRAMETER SELECTIONNote: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Wire: 0.032 Esn. Wire: B1 or C6 S/S Hole: 35

F/S Wire: 0.025 Esn. Wire: B2 F/S Hole: 30Welds with reinforcement: S/S Wire: 0.040 Esn. Wire: C5 S/S Hole: 40

F/S Wire: 0.032 Esn. Wire: B1 or C6 F/S Hole: 35Maximum allowable reinforcement: 0.0625"/per sideMaximum reinforcement with DWE/SWV: 0.125" Total of walls + reinforcement: 3.875" 98.4250 mmMaximum reinforcement with DWE/DWV: 0.125" Total of walls + reinforcement: 3.875" 98.4250 mmMaximum reinforcement with SWE/SWV: 0.0625" Total of wall + reinforcement: 1.9375" 49.2125 mm

INADEQUATE PENETRATION WITHOUT HIGH LOWMaximum length of individual indication of IP : 1 inch or 25mmMaximum length of IP in 8% of weld: N/A since total weld exceeds 12 inchesMaximum length of indications in any continuous 12" length of weld: 1" 25 mm

INADEQUATE PENETRATION DUE TO HIGH LOWMaximum length of individual indication of IPD: 2 inches or 50mmMaximum length of indications of IPD in any continuous 12" length of weld: 3" 75 mm

INADEQUATE CROSS PENETRATIONMaximum length of an individual indication of ICP: 2 inches or 50mmMaximum length of indications of ICP in any continuous 12" length of weld: 2" 50 mm

INCOMPLETE FUSIONMaximum length of an individual indication of IF: 1 inch or 25mmMaximum length of IF in 8% of weld: N/A since total weld exceeds 12 inchesMaximum length of indications of IF in any continuous 12" length of weld: 1" 25 mm

INCOMPLETE FUSION DUE TO COLD LAPMaximum length of individual indications of IFD: 2 inches or 50mmMaximum length of IFD in 8% of weld: 140.5941 mmMaximum length of indications of IFD in any continuous 12" length of weld: 2" 25 mm

INTERNAL CONCAVITY Any length of IC is acceptable, provided the density of the radiographic image of the internal concavity does not exceed that of the thinnest adjacent parent material. For areas that exceed the density of thethinnest adjacent parent material, the criteria for burn through are applicable.

BURN - THROUGHMaximum dimension of BT's image : unacceptable if it exceeds that of the thinnest adjacent parent metal.Maximum dimension of BT: 1/4" or 6mmMaximum dimension is unacceptable if: it exceeds the thinner of the nonnal wall thickness joined, and the density

of the BT's image exceeds that of the thinnest adjacent parent material.The sum of the max dimensions of separate BBT's whose image density exceeds that of the thinnest adjacent parentmaterial exceeds 1/2 inch or 13mm in any continuous 12" length of weld or the total weld length(whichever is less).

API - 110422" s/140 - 1.875" Wall

Page 1 of 2

Page 171: NDT Code Book Made Easy

API - 110422" s/140 - 1.875" Wall

SLAG INCLUSIONSElongated slag inclusions (ESI)Maximum length of an ESI: 2 inches or 50mmParallel ESI indications (Wagon Tracks) shall be considered a single indication unless the width of either of them exceed1/32" or 0.8mm. In that event they shall be considered separate indications.Maximum length of ESI indications in any continuous 12" length of weld: 2" 50 mmMaximum width of an individual ESI indication: 1/16" or 1.6mmIsolated slag inclusions (ISI)Maximum length of ISI indications in any continuous 12" length of weld: 1/2" 13 mmMaximum width of an ISI indication: 1/8" or 3mmMaximum length of ESI and ISI in 8% of weld: 140.5941 mm

POROSITY Individual or Scattered Porosity.Maximum size of an individual pore: 1/8" or 3mmThe size of an individual pore exceeds 25% of the thinner of the nonimal wall thickness joined.The distribution of scattered porosity exceeds the concentration permitted in Figures 19 or 20.Cluster Porosity (CP)Maximum diameter of the cluster: 1/2 inch or 13mmMaximum length of CP indications in any continuous 12" length of weweld: 1/2" 13 mmMaximum length of an individual pore within a cluster: 1/16 inch or 2mmHollow Bead Porosity (HB)Maximum length of an individual indication of HB: 1/2 inch or 13mmMaximum length of HB indications in any continuous 12" length of weld: 2" 50 mmMaximum length of HB in 8% of weld: 140.5941 mmNOTE: The weld is unacceptable if individual indications of HB, each greater than 1/4 inch or 6mm in length, are seperated by less than 2 inches or 50 mm.

CRACKSNote: Any crack which is not a shallow crater crack or star crack is unacceptable.Maximum length of shallow crater cracks or star cracks: 5/32 inch or 4mm

UNDERCUTTINGUndercutting adjacent to the cover pass (EU) and Undercutting adjacent to the root pass (IU)Maximum length of EU and IU indications (in any combination) in a 12 inch length of weld: 2" 50 mmMaximum length of EU and IU indications: 11.532" 292.9128 mm (This value is 1/6 th of the total weld length)

ACCUMULATION OF IMPERFECTIONSMaximum length of AI indications in any continuous 12 inch or 300 mm length of weld: 2" 50 mmMaximum length of AI indications of 8% of weld: 140.5941 mm

RADIOGRAPHIC INFOPipe O.D. in inches: 22.00"Amount of Penetrameters required for each shot: 1 penetrameter 1" from the end of film and 1 penny in the center.Total weld length: 69.19" 1757.4260 mmCassette size to complete weld in most efficient way: 3.5 x 17" 4.5 x 17"Amount of shots to complete weld with 1" on each side of readable film: 68% of weld: 5.5352" 140.5941 mmHole penetrameters are adjacent to the weld and Wire penetrameters are parallel to the weld.

Page 2 of 2

Page 172: NDT Code Book Made Easy

PENETRAMETER SELECTIONNote: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Wire: 0.040 Esn. Wire: C5 S/S Hole: 40

F/S Wire: 0.032 Esn. Wire: B1 or C6 F/S Hole: 35Welds with reinforcement: S/S Wire: 0.050 Esn. Wire: C4 S/S Hole: 50

F/S Wire: 0.040 Esn. Wire: C5 F/S Hole: 40Maximum allowable reinforcement: 0.0625"/per sideMaximum reinforcement with DWE/SWV: 0.125" Total of walls + reinforcement: 4.375" 111.1250 mmMaximum reinforcement with DWE/DWV: 0.125" Total of walls + reinforcement: 4.375" 111.1250 mmMaximum reinforcement with SWE/SWV: 0.0625" Total of wall + reinforcement: 2.1875" 55.5625 mm

INADEQUATE PENETRATION WITHOUT HIGH LOWMaximum length of individual indication of IP : 1 inch or 25mmMaximum length of IP in 8% of weld: N/A since total weld exceeds 12 inchesMaximum length of indications in any continuous 12" length of weld: 1" 25 mm

INADEQUATE PENETRATION DUE TO HIGH LOWMaximum length of individual indication of IPD: 2 inches or 50mmMaximum length of indications of IPD in any continuous 12" length of weld: 3" 75 mm

INADEQUATE CROSS PENETRATIONMaximum length of an individual indication of ICP: 2 inches or 50mmMaximum length of indications of ICP in any continuous 12" length of weld: 2" 50 mm

INCOMPLETE FUSIONMaximum length of an individual indication of IF: 1 inch or 25mmMaximum length of IF in 8% of weld: N/A since total weld exceeds 12 inchesMaximum length of indications of IF in any continuous 12" length of weld: 1" 25 mm

INCOMPLETE FUSION DUE TO COLD LAPMaximum length of individual indications of IFD: 2 inches or 50mmMaximum length of IFD in 8% of weld: 140.5941 mmMaximum length of indications of IFD in any continuous 12" length of weld: 2" 25 mm

INTERNAL CONCAVITY Any length of IC is acceptable, provided the density of the radiographic image of the internal concavity does not exceed that of the thinnest adjacent parent material. For areas that exceed the density of thethinnest adjacent parent material, the criteria for burn through are applicable.

BURN - THROUGHMaximum dimension of BT's image : unacceptable if it exceeds that of the thinnest adjacent parent metal.Maximum dimension of BT: 1/4" or 6mmMaximum dimension is unacceptable if: it exceeds the thinner of the nonnal wall thickness joined, and the density

of the BT's image exceeds that of the thinnest adjacent parent material.The sum of the max dimensions of separate BBT's whose image density exceeds that of the thinnest adjacent parentmaterial exceeds 1/2 inch or 13mm in any continuous 12" length of weld or the total weld length(whichever is less).

API - 110422" s/160 - 2.125" Wall

Page 1 of 2

Page 173: NDT Code Book Made Easy

API - 110422" s/160 - 2.125" Wall

SLAG INCLUSIONSElongated slag inclusions (ESI)Maximum length of an ESI: 2 inches or 50mmParallel ESI indications (Wagon Tracks) shall be considered a single indication unless the width of either of them exceed1/32" or 0.8mm. In that event they shall be considered separate indications.Maximum length of ESI indications in any continuous 12" length of weld: 2" 50 mmMaximum width of an individual ESI indication: 1/16" or 1.6mmIsolated slag inclusions (ISI)Maximum length of ISI indications in any continuous 12" length of weld: 1/2" 13 mmMaximum width of an ISI indication: 1/8" or 3mmMaximum length of ESI and ISI in 8% of weld: 140.5941 mm

POROSITY Individual or Scattered Porosity.Maximum size of an individual pore: 1/8" or 3mmThe size of an individual pore exceeds 25% of the thinner of the nonimal wall thickness joined.The distribution of scattered porosity exceeds the concentration permitted in Figures 19 or 20.Cluster Porosity (CP)Maximum diameter of the cluster: 1/2 inch or 13mmMaximum length of CP indications in any continuous 12" length of weweld: 1/2" 13 mmMaximum length of an individual pore within a cluster: 1/16 inch or 2mmHollow Bead Porosity (HB)Maximum length of an individual indication of HB: 1/2 inch or 13mmMaximum length of HB indications in any continuous 12" length of weld: 2" 50 mmMaximum length of HB in 8% of weld: 140.5941 mmNOTE: The weld is unacceptable if individual indications of HB, each greater than 1/4 inch or 6mm in length, are seperated by less than 2 inches or 50 mm.

CRACKSNote: Any crack which is not a shallow crater crack or star crack is unacceptable.Maximum length of shallow crater cracks or star cracks: 5/32 inch or 4mm

UNDERCUTTINGUndercutting adjacent to the cover pass (EU) and Undercutting adjacent to the root pass (IU)Maximum length of EU and IU indications (in any combination) in a 12 inch length of weld: 2" 50 mmMaximum length of EU and IU indications: 11.532" 292.9128 mm (This value is 1/6 th of the total weld length)

ACCUMULATION OF IMPERFECTIONSMaximum length of AI indications in any continuous 12 inch or 300 mm length of weld: 2" 50 mmMaximum length of AI indications of 8% of weld: 140.5941 mm

RADIOGRAPHIC INFOPipe O.D. in inches: 22.00"Amount of Penetrameters required for each shot: 1 penetrameter 1" from the end of film and 1 penny in the center.Total weld length: 69.19" 1757.4260 mmCassette size to complete weld in most efficient way: 3.5 x 17" 4.5 x 17"Amount of shots to complete weld with 1" on each side of readable film: 68% of weld: 5.5352" 140.5941 mmHole penetrameters are adjacent to the weld and Wire penetrameters are parallel to the weld.

Page 2 of 2

Page 174: NDT Code Book Made Easy

PENETRAMETER SELECTIONNote: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Wire: 0.008 Esn. Wire: A2 S/S Hole: 12

F/S Wire: 0.006 Esn. Wire: A3 F/S Hole: 10Welds with reinforcement: S/S Wire: 0.010 Esn. Wire: A1 or B6 S/S Hole: 15

F/S Wire: 0.008 Esn. Wire: A2 F/S Hole: 12Maximum allowable reinforcement: 0.0625"/per sideMaximum reinforcement with DWE/SWV: 0.125" Total of walls + reinforcement: 0.625" 15.8750 mmMaximum reinforcement with DWE/DWV: 0.125" Total of walls + reinforcement: 0.625" 15.8750 mmMaximum reinforcement with SWE/SWV: 0.0625" Total of wall + reinforcement: 0.3125" 7.9375 mm

INADEQUATE PENETRATION WITHOUT HIGH LOWMaximum length of individual indication of IP : 1 inch or 25mmMaximum length of IP in 8% of weld: N/A since total weld exceeds 12 inchesMaximum length of indications in any continuous 12" length of weld: 1" 25 mm

INADEQUATE PENETRATION DUE TO HIGH LOWMaximum length of individual indication of IPD: 2 inches or 50mmMaximum length of indications of IPD in any continuous 12" length of weld: 3" 75 mm

INADEQUATE CROSS PENETRATIONMaximum length of an individual indication of ICP: 2 inches or 50mmMaximum length of indications of ICP in any continuous 12" length of weld: 2" 50 mm

INCOMPLETE FUSIONMaximum length of an individual indication of IF: 1 inch or 25mmMaximum length of IF in 8% of weld: N/A since total weld exceeds 12 inchesMaximum length of indications of IF in any continuous 12" length of weld: 1" 25 mm

INCOMPLETE FUSION DUE TO COLD LAPMaximum length of individual indications of IFD: 2 inches or 50mmMaximum length of IFD in 8% of weld: 153.3754 mmMaximum length of indications of IFD in any continuous 12" length of weld: 2" 25 mm

INTERNAL CONCAVITY Any length of IC is acceptable, provided the density of the radiographic image of the internal concavity does not exceed that of the thinnest adjacent parent material. For areas that exceed the density of thethinnest adjacent parent material, the criteria for burn through are applicable.

BURN - THROUGHMaximum dimension of BT's image : unacceptable if it exceeds that of the thinnest adjacent parent metal.Maximum dimension of BT: 1/4" or 6mmMaximum dimension is unacceptable if: it exceeds the thinner of the nonnal wall thickness joined, and the density

of the BT's image exceeds that of the thinnest adjacent parent material.The sum of the max dimensions of separate BBT's whose image density exceeds that of the thinnest adjacent parentmaterial exceeds 1/2 inch or 13mm in any continuous 12" length of weld or the total weld length(whichever is less).

API - 110424" s/10 - 0.250" Wall

Page 1 of 2

Page 175: NDT Code Book Made Easy

API - 110424" s/10 - 0.250" Wall

SLAG INCLUSIONSElongated slag inclusions (ESI)Maximum length of an ESI: 2 inches or 50mmParallel ESI indications (Wagon Tracks) shall be considered a single indication unless the width of either of them exceed1/32" or 0.8mm. In that event they shall be considered separate indications.Maximum length of ESI indications in any continuous 12" length of weld: 2" 50 mmMaximum width of an individual ESI indication: 1/16" or 1.6mmIsolated slag inclusions (ISI)Maximum length of ISI indications in any continuous 12" length of weld: 1/2" 13 mmMaximum width of an ISI indication: 1/8" or 3mmMaximum length of ESI and ISI in 8% of weld: 153.3754 mm

POROSITY Individual or Scattered Porosity.Maximum size of an individual pore: 1/8" or 3mmThe size of an individual pore exceeds 25% of the thinner of the nonimal wall thickness joined.The distribution of scattered porosity exceeds the concentration permitted in Figures 19 or 20.Cluster Porosity (CP)Maximum diameter of the cluster: 1/2 inch or 13mmMaximum length of CP indications in any continuous 12" length of weweld: 1/2" 13 mmMaximum length of an individual pore within a cluster: 1/16 inch or 2mmHollow Bead Porosity (HB)Maximum length of an individual indication of HB: 1/2 inch or 13mmMaximum length of HB indications in any continuous 12" length of weld: 2" 50 mmMaximum length of HB in 8% of weld: 153.3754 mmNOTE: The weld is unacceptable if individual indications of HB, each greater than 1/4 inch or 6mm in length, are seperated by less than 2 inches or 50 mm.

CRACKSNote: Any crack which is not a shallow crater crack or star crack is unacceptable.Maximum length of shallow crater cracks or star cracks: 5/32 inch or 4mm

UNDERCUTTINGUndercutting adjacent to the cover pass (EU) and Undercutting adjacent to the root pass (IU)Maximum length of EU and IU indications (in any combination) in a 12 inch length of weld: 2" 50 mmMaximum length of EU and IU indications: 12.58" 319.5320 mm (This value is 1/6 th of the total weld length)

ACCUMULATION OF IMPERFECTIONSMaximum length of AI indications in any continuous 12 inch or 300 mm length of weld: 2" 50 mmMaximum length of AI indications of 8% of weld: 153.3754 mm

RADIOGRAPHIC INFOPipe O.D. in inches: 24.00"Amount of Penetrameters required for each shot: 1 penetrameter 1" from the end of film and 1 penny in the center.Total weld length: 75.48" 1917.1920 mmCassette size to complete weld in most efficient way: 3.5 x 17" 4.5 x 17"Amount of shots to complete weld with 1" on each side of readable film: 68% of weld: 6.0384" 153.3754 mmHole penetrameters are adjacent to the weld and Wire penetrameters are parallel to the weld.

Page 2 of 2

Page 176: NDT Code Book Made Easy

PENETRAMETER SELECTIONNote: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Wire: 0.016 Esn. Wire: B4 S/S Hole: 20

F/S Wire: 0.013 Esn. Wire: B5 F/S Hole: 17Welds with reinforcement: S/S Wire: 0.020 Esn. Wire: B3 S/S Hole: 25

F/S Wire: 0.016 Esn. Wire: B4 F/S Hole: 20Maximum allowable reinforcement: 0.0625"/per sideMaximum reinforcement with DWE/SWV: 0.125" Total of walls + reinforcement: 1.499" 38.0746 mmMaximum reinforcement with DWE/DWV: 0.125" Total of walls + reinforcement: 1.499" 38.0746 mmMaximum reinforcement with SWE/SWV: 0.0625" Total of wall + reinforcement: 0.7495" 19.0373 mm

INADEQUATE PENETRATION WITHOUT HIGH LOWMaximum length of individual indication of IP : 1 inch or 25mmMaximum length of IP in 8% of weld: N/A since total weld exceeds 12 inchesMaximum length of indications in any continuous 12" length of weld: 1" 25 mm

INADEQUATE PENETRATION DUE TO HIGH LOWMaximum length of individual indication of IPD: 2 inches or 50mmMaximum length of indications of IPD in any continuous 12" length of weld: 3" 75 mm

INADEQUATE CROSS PENETRATIONMaximum length of an individual indication of ICP: 2 inches or 50mmMaximum length of indications of ICP in any continuous 12" length of weld: 2" 50 mm

INCOMPLETE FUSIONMaximum length of an individual indication of IF: 1 inch or 25mmMaximum length of IF in 8% of weld: N/A since total weld exceeds 12 inchesMaximum length of indications of IF in any continuous 12" length of weld: 1" 25 mm

INCOMPLETE FUSION DUE TO COLD LAPMaximum length of individual indications of IFD: 2 inches or 50mmMaximum length of IFD in 8% of weld: 153.3754 mmMaximum length of indications of IFD in any continuous 12" length of weld: 2" 25 mm

INTERNAL CONCAVITY Any length of IC is acceptable, provided the density of the radiographic image of the internal concavity does not exceed that of the thinnest adjacent parent material. For areas that exceed the density of thethinnest adjacent parent material, the criteria for burn through are applicable.

BURN - THROUGHMaximum dimension of BT's image : unacceptable if it exceeds that of the thinnest adjacent parent metal.Maximum dimension of BT: 1/4" or 6mmMaximum dimension is unacceptable if: it exceeds the thinner of the nonnal wall thickness joined, and the density

of the BT's image exceeds that of the thinnest adjacent parent material.The sum of the max dimensions of separate BBT's whose image density exceeds that of the thinnest adjacent parentmaterial exceeds 1/2 inch or 13mm in any continuous 12" length of weld or the total weld length(whichever is less).

API - 110424" s/40 - 0.687" Wall

Page 1 of 2

Page 177: NDT Code Book Made Easy

API - 110424" s/40 - 0.687" Wall

SLAG INCLUSIONSElongated slag inclusions (ESI)Maximum length of an ESI: 2 inches or 50mmParallel ESI indications (Wagon Tracks) shall be considered a single indication unless the width of either of them exceed1/32" or 0.8mm. In that event they shall be considered separate indications.Maximum length of ESI indications in any continuous 12" length of weld: 2" 50 mmMaximum width of an individual ESI indication: 1/16" or 1.6mmIsolated slag inclusions (ISI)Maximum length of ISI indications in any continuous 12" length of weld: 1/2" 13 mmMaximum width of an ISI indication: 1/8" or 3mmMaximum length of ESI and ISI in 8% of weld: 153.3754 mm

POROSITY Individual or Scattered Porosity.Maximum size of an individual pore: 1/8" or 3mmThe size of an individual pore exceeds 25% of the thinner of the nonimal wall thickness joined.The distribution of scattered porosity exceeds the concentration permitted in Figures 19 or 20.Cluster Porosity (CP)Maximum diameter of the cluster: 1/2 inch or 13mmMaximum length of CP indications in any continuous 12" length of weweld: 1/2" 13 mmMaximum length of an individual pore within a cluster: 1/16 inch or 2mmHollow Bead Porosity (HB)Maximum length of an individual indication of HB: 1/2 inch or 13mmMaximum length of HB indications in any continuous 12" length of weld: 2" 50 mmMaximum length of HB in 8% of weld: 153.3754 mmNOTE: The weld is unacceptable if individual indications of HB, each greater than 1/4 inch or 6mm in length, are seperated by less than 2 inches or 50 mm.

CRACKSNote: Any crack which is not a shallow crater crack or star crack is unacceptable.Maximum length of shallow crater cracks or star cracks: 5/32 inch or 4mm

UNDERCUTTINGUndercutting adjacent to the cover pass (EU) and Undercutting adjacent to the root pass (IU)Maximum length of EU and IU indications (in any combination) in a 12 inch length of weld: 2" 50 mmMaximum length of EU and IU indications: 12.58" 319.5320 mm (This value is 1/6 th of the total weld length)

ACCUMULATION OF IMPERFECTIONSMaximum length of AI indications in any continuous 12 inch or 300 mm length of weld: 2" 50 mmMaximum length of AI indications of 8% of weld: 153.3754 mm

RADIOGRAPHIC INFOPipe O.D. in inches: 24.00"Amount of Penetrameters required for each shot: 1 penetrameter 1" from the end of film and 1 penny in the center.Total weld length: 75.48" 1917.1920 mmCassette size to complete weld in most efficient way: 3.5 x 17" 4.5 x 17"Amount of shots to complete weld with 1" on each side of readable film: 68% of weld: 6.0384" 153.3754 mmHole penetrameters are adjacent to the weld and Wire penetrameters are parallel to the weld.

Page 2 of 2

Page 178: NDT Code Book Made Easy

PENETRAMETER SELECTIONNote: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Wire: 0.010 Esn. Wire: A1 or B6 S/S Hole: 15

F/S Wire: 0.008 Esn. Wire: A2 F/S Hole: 12Welds with reinforcement: S/S Wire: 0.013 Esn. Wire: B5 S/S Hole: 17

F/S Wire: 0.010 Esn. Wire: A1 or B6 F/S Hole: 15Maximum allowable reinforcement: 0.0625"/per sideMaximum reinforcement with DWE/SWV: 0.125" Total of walls + reinforcement: 0.875" 22.2250 mmMaximum reinforcement with DWE/DWV: 0.125" Total of walls + reinforcement: 0.875" 22.2250 mmMaximum reinforcement with SWE/SWV: 0.0625" Total of wall + reinforcement: 0.4375" 11.1125 mm

INADEQUATE PENETRATION WITHOUT HIGH LOWMaximum length of individual indication of IP : 1 inch or 25mmMaximum length of IP in 8% of weld: N/A since total weld exceeds 12 inchesMaximum length of indications in any continuous 12" length of weld: 1" 25 mm

INADEQUATE PENETRATION DUE TO HIGH LOWMaximum length of individual indication of IPD: 2 inches or 50mmMaximum length of indications of IPD in any continuous 12" length of weld: 3" 75 mm

INADEQUATE CROSS PENETRATIONMaximum length of an individual indication of ICP: 2 inches or 50mmMaximum length of indications of ICP in any continuous 12" length of weld: 2" 50 mm

INCOMPLETE FUSIONMaximum length of an individual indication of IF: 1 inch or 25mmMaximum length of IF in 8% of weld: N/A since total weld exceeds 12 inchesMaximum length of indications of IF in any continuous 12" length of weld: 1" 25 mm

INCOMPLETE FUSION DUE TO COLD LAPMaximum length of individual indications of IFD: 2 inches or 50mmMaximum length of IFD in 8% of weld: 153.3754 mmMaximum length of indications of IFD in any continuous 12" length of weld: 2" 25 mm

INTERNAL CONCAVITY Any length of IC is acceptable, provided the density of the radiographic image of the internal concavity does not exceed that of the thinnest adjacent parent material. For areas that exceed the density of thethinnest adjacent parent material, the criteria for burn through are applicable.

BURN - THROUGHMaximum dimension of BT's image : unacceptable if it exceeds that of the thinnest adjacent parent metal.Maximum dimension of BT: 1/4" or 6mmMaximum dimension is unacceptable if: it exceeds the thinner of the nonnal wall thickness joined, and the density

of the BT's image exceeds that of the thinnest adjacent parent material.The sum of the max dimensions of separate BBT's whose image density exceeds that of the thinnest adjacent parentmaterial exceeds 1/2 inch or 13mm in any continuous 12" length of weld or the total weld length(whichever is less).

API - 110424" Standard - 0.375" Wall

Page 1 of 2

Page 179: NDT Code Book Made Easy

API - 110424" Standard - 0.375" Wall

SLAG INCLUSIONSElongated slag inclusions (ESI)Maximum length of an ESI: 2 inches or 50mmParallel ESI indications (Wagon Tracks) shall be considered a single indication unless the width of either of them exceed1/32" or 0.8mm. In that event they shall be considered separate indications.Maximum length of ESI indications in any continuous 12" length of weld: 2" 50 mmMaximum width of an individual ESI indication: 1/16" or 1.6mmIsolated slag inclusions (ISI)Maximum length of ISI indications in any continuous 12" length of weld: 1/2" 13 mmMaximum width of an ISI indication: 1/8" or 3mmMaximum length of ESI and ISI in 8% of weld: 153.3754 mm

POROSITY Individual or Scattered Porosity.Maximum size of an individual pore: 1/8" or 3mmThe size of an individual pore exceeds 25% of the thinner of the nonimal wall thickness joined.The distribution of scattered porosity exceeds the concentration permitted in Figures 19 or 20.Cluster Porosity (CP)Maximum diameter of the cluster: 1/2 inch or 13mmMaximum length of CP indications in any continuous 12" length of weweld: 1/2" 13 mmMaximum length of an individual pore within a cluster: 1/16 inch or 2mmHollow Bead Porosity (HB)Maximum length of an individual indication of HB: 1/2 inch or 13mmMaximum length of HB indications in any continuous 12" length of weld: 2" 50 mmMaximum length of HB in 8% of weld: 153.3754 mmNOTE: The weld is unacceptable if individual indications of HB, each greater than 1/4 inch or 6mm in length, are seperated by less than 2 inches or 50 mm.

CRACKSNote: Any crack which is not a shallow crater crack or star crack is unacceptable.Maximum length of shallow crater cracks or star cracks: 5/32 inch or 4mm

UNDERCUTTINGUndercutting adjacent to the cover pass (EU) and Undercutting adjacent to the root pass (IU)Maximum length of EU and IU indications (in any combination) in a 12 inch length of weld: 2" 50 mmMaximum length of EU and IU indications: 12.58" 319.5320 mm (This value is 1/6 th of the total weld length)

ACCUMULATION OF IMPERFECTIONSMaximum length of AI indications in any continuous 12 inch or 300 mm length of weld: 2" 50 mmMaximum length of AI indications of 8% of weld: 153.3754 mm

RADIOGRAPHIC INFOPipe O.D. in inches: 24.00"Amount of Penetrameters required for each shot: 1 penetrameter 1" from the end of film and 1 penny in the center.Total weld length: 75.48" 1917.1920 mmCassette size to complete weld in most efficient way: 3.5 x 17" 4.5 x 17"Amount of shots to complete weld with 1" on each side of readable film: 68% of weld: 6.0384" 153.3754 mmHole penetrameters are adjacent to the weld and Wire penetrameters are parallel to the weld.

Page 2 of 2

Page 180: NDT Code Book Made Easy

PENETRAMETER SELECTIONNote: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Wire: 0.013 Esn. Wire: B5 S/S Hole: 17

F/S Wire: 0.010 Esn. Wire: A1 or B6 F/S Hole: 15Welds with reinforcement: S/S Wire: 0.016 Esn. Wire: B4 S/S Hole: 20

F/S Wire: 0.013 Esn. Wire: B5 F/S Hole: 17Maximum allowable reinforcement: 0.0625"/per sideMaximum reinforcement with DWE/SWV: 0.125" Total of walls + reinforcement: 1.125" 28.5750 mmMaximum reinforcement with DWE/DWV: 0.125" Total of walls + reinforcement: 1.125" 28.5750 mmMaximum reinforcement with SWE/SWV: 0.0625" Total of wall + reinforcement: 0.5625" 14.2875 mm

INADEQUATE PENETRATION WITHOUT HIGH LOWMaximum length of individual indication of IP : 1 inch or 25mmMaximum length of IP in 8% of weld: N/A since total weld exceeds 12 inchesMaximum length of indications in any continuous 12" length of weld: 1" 25 mm

INADEQUATE PENETRATION DUE TO HIGH LOWMaximum length of individual indication of IPD: 2 inches or 50mmMaximum length of indications of IPD in any continuous 12" length of weld: 3" 75 mm

INADEQUATE CROSS PENETRATIONMaximum length of an individual indication of ICP: 2 inches or 50mmMaximum length of indications of ICP in any continuous 12" length of weld: 2" 50 mm

INCOMPLETE FUSIONMaximum length of an individual indication of IF: 1 inch or 25mmMaximum length of IF in 8% of weld: N/A since total weld exceeds 12 inchesMaximum length of indications of IF in any continuous 12" length of weld: 1" 25 mm

INCOMPLETE FUSION DUE TO COLD LAPMaximum length of individual indications of IFD: 2 inches or 50mmMaximum length of IFD in 8% of weld: 153.3754 mmMaximum length of indications of IFD in any continuous 12" length of weld: 2" 25 mm

INTERNAL CONCAVITY Any length of IC is acceptable, provided the density of the radiographic image of the internal concavity does not exceed that of the thinnest adjacent parent material. For areas that exceed the density of thethinnest adjacent parent material, the criteria for burn through are applicable.

BURN - THROUGHMaximum dimension of BT's image : unacceptable if it exceeds that of the thinnest adjacent parent metal.Maximum dimension of BT: 1/4" or 6mmMaximum dimension is unacceptable if: it exceeds the thinner of the nonnal wall thickness joined, and the density

of the BT's image exceeds that of the thinnest adjacent parent material.The sum of the max dimensions of separate BBT's whose image density exceeds that of the thinnest adjacent parentmaterial exceeds 1/2 inch or 13mm in any continuous 12" length of weld or the total weld length(whichever is less).

API - 110424" Extra Strong - 0.500" Wall

Page 1 of 2

Page 181: NDT Code Book Made Easy

API - 110424" Extra Strong - 0.500" Wall

SLAG INCLUSIONSElongated slag inclusions (ESI)Maximum length of an ESI: 2 inches or 50mmParallel ESI indications (Wagon Tracks) shall be considered a single indication unless the width of either of them exceed1/32" or 0.8mm. In that event they shall be considered separate indications.Maximum length of ESI indications in any continuous 12" length of weld: 2" 50 mmMaximum width of an individual ESI indication: 1/16" or 1.6mmIsolated slag inclusions (ISI)Maximum length of ISI indications in any continuous 12" length of weld: 1/2" 13 mmMaximum width of an ISI indication: 1/8" or 3mmMaximum length of ESI and ISI in 8% of weld: 153.3754 mm

POROSITY Individual or Scattered Porosity.Maximum size of an individual pore: 1/8" or 3mmThe size of an individual pore exceeds 25% of the thinner of the nonimal wall thickness joined.The distribution of scattered porosity exceeds the concentration permitted in Figures 19 or 20.Cluster Porosity (CP)Maximum diameter of the cluster: 1/2 inch or 13mmMaximum length of CP indications in any continuous 12" length of weweld: 1/2" 13 mmMaximum length of an individual pore within a cluster: 1/16 inch or 2mmHollow Bead Porosity (HB)Maximum length of an individual indication of HB: 1/2 inch or 13mmMaximum length of HB indications in any continuous 12" length of weld: 2" 50 mmMaximum length of HB in 8% of weld: 153.3754 mmNOTE: The weld is unacceptable if individual indications of HB, each greater than 1/4 inch or 6mm in length, are seperated by less than 2 inches or 50 mm.

CRACKSNote: Any crack which is not a shallow crater crack or star crack is unacceptable.Maximum length of shallow crater cracks or star cracks: 5/32 inch or 4mm

UNDERCUTTINGUndercutting adjacent to the cover pass (EU) and Undercutting adjacent to the root pass (IU)Maximum length of EU and IU indications (in any combination) in a 12 inch length of weld: 2" 50 mmMaximum length of EU and IU indications: 12.58" 319.5320 mm (This value is 1/6 th of the total weld length)

ACCUMULATION OF IMPERFECTIONSMaximum length of AI indications in any continuous 12 inch or 300 mm length of weld: 2" 50 mmMaximum length of AI indications of 8% of weld: 153.3754 mm

RADIOGRAPHIC INFOPipe O.D. in inches: 24.00"Amount of Penetrameters required for each shot: 1 penetrameter 1" from the end of film and 1 penny in the center.Total weld length: 75.48" 1917.1920 mmCassette size to complete weld in most efficient way: 3.5 x 17" 4.5 x 17"Amount of shots to complete weld with 1" on each side of readable film: 68% of weld: 6.0384" 153.3754 mmHole penetrameters are adjacent to the weld and Wire penetrameters are parallel to the weld.

Page 2 of 2

Page 182: NDT Code Book Made Easy

PENETRAMETER SELECTIONNote: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Wire: 0.025 Esn. Wire: B2 S/S Hole: 30

F/S Wire: 0.020 Esn. Wire: B3 F/S Hole: 25Welds with reinforcement: S/S Wire: 0.025 Esn. Wire: B2 S/S Hole: 30

F/S Wire: 0.020 Esn. Wire: B3 F/S Hole: 25Maximum allowable reinforcement: 0.0625"/per sideMaximum reinforcement with DWE/SWV: 0.125" Total of walls + reinforcement: 2.561" 65.0494 mmMaximum reinforcement with DWE/DWV: 0.125" Total of walls + reinforcement: 2.561" 65.0494 mmMaximum reinforcement with SWE/SWV: 0.0625" Total of wall + reinforcement: 1.2805" 32.5247 mm

INADEQUATE PENETRATION WITHOUT HIGH LOWMaximum length of individual indication of IP : 1 inch or 25mmMaximum length of IP in 8% of weld: N/A since total weld exceeds 12 inchesMaximum length of indications in any continuous 12" length of weld: 1" 25 mm

INADEQUATE PENETRATION DUE TO HIGH LOWMaximum length of individual indication of IPD: 2 inches or 50mmMaximum length of indications of IPD in any continuous 12" length of weld: 3" 75 mm

INADEQUATE CROSS PENETRATIONMaximum length of an individual indication of ICP: 2 inches or 50mmMaximum length of indications of ICP in any continuous 12" length of weld: 2" 50 mm

INCOMPLETE FUSIONMaximum length of an individual indication of IF: 1 inch or 25mmMaximum length of IF in 8% of weld: N/A since total weld exceeds 12 inchesMaximum length of indications of IF in any continuous 12" length of weld: 1" 25 mm

INCOMPLETE FUSION DUE TO COLD LAPMaximum length of individual indications of IFD: 2 inches or 50mmMaximum length of IFD in 8% of weld: 153.3754 mmMaximum length of indications of IFD in any continuous 12" length of weld: 2" 25 mm

INTERNAL CONCAVITY Any length of IC is acceptable, provided the density of the radiographic image of the internal concavity does not exceed that of the thinnest adjacent parent material. For areas that exceed the density of thethinnest adjacent parent material, the criteria for burn through are applicable.

BURN - THROUGHMaximum dimension of BT's image : unacceptable if it exceeds that of the thinnest adjacent parent metal.Maximum dimension of BT: 1/4" or 6mmMaximum dimension is unacceptable if: it exceeds the thinner of the nonnal wall thickness joined, and the density

of the BT's image exceeds that of the thinnest adjacent parent material.The sum of the max dimensions of separate BBT's whose image density exceeds that of the thinnest adjacent parentmaterial exceeds 1/2 inch or 13mm in any continuous 12" length of weld or the total weld length(whichever is less).

API - 110424" s/80 - 1.218" Wall

Page 1 of 2

Page 183: NDT Code Book Made Easy

API - 110424" s/80 - 1.218" Wall

SLAG INCLUSIONSElongated slag inclusions (ESI)Maximum length of an ESI: 2 inches or 50mmParallel ESI indications (Wagon Tracks) shall be considered a single indication unless the width of either of them exceed1/32" or 0.8mm. In that event they shall be considered separate indications.Maximum length of ESI indications in any continuous 12" length of weld: 2" 50 mmMaximum width of an individual ESI indication: 1/16" or 1.6mmIsolated slag inclusions (ISI)Maximum length of ISI indications in any continuous 12" length of weld: 1/2" 13 mmMaximum width of an ISI indication: 1/8" or 3mmMaximum length of ESI and ISI in 8% of weld: 153.3754 mm

POROSITY Individual or Scattered Porosity.Maximum size of an individual pore: 1/8" or 3mmThe size of an individual pore exceeds 25% of the thinner of the nonimal wall thickness joined.The distribution of scattered porosity exceeds the concentration permitted in Figures 19 or 20.Cluster Porosity (CP)Maximum diameter of the cluster: 1/2 inch or 13mmMaximum length of CP indications in any continuous 12" length of weweld: 1/2" 13 mmMaximum length of an individual pore within a cluster: 1/16 inch or 2mmHollow Bead Porosity (HB)Maximum length of an individual indication of HB: 1/2 inch or 13mmMaximum length of HB indications in any continuous 12" length of weld: 2" 50 mmMaximum length of HB in 8% of weld: 153.3754 mmNOTE: The weld is unacceptable if individual indications of HB, each greater than 1/4 inch or 6mm in length, are seperated by less than 2 inches or 50 mm.

CRACKSNote: Any crack which is not a shallow crater crack or star crack is unacceptable.Maximum length of shallow crater cracks or star cracks: 5/32 inch or 4mm

UNDERCUTTINGUndercutting adjacent to the cover pass (EU) and Undercutting adjacent to the root pass (IU)Maximum length of EU and IU indications (in any combination) in a 12 inch length of weld: 2" 50 mmMaximum length of EU and IU indications: 12.58" 319.5320 mm (This value is 1/6 th of the total weld length)

ACCUMULATION OF IMPERFECTIONSMaximum length of AI indications in any continuous 12 inch or 300 mm length of weld: 2" 50 mmMaximum length of AI indications of 8% of weld: 153.3754 mm

RADIOGRAPHIC INFOPipe O.D. in inches: 24.00"Amount of Penetrameters required for each shot: 1 penetrameter 1" from the end of film and 1 penny in the center.Total weld length: 75.48" 1917.1920 mmCassette size to complete weld in most efficient way: 3.5 x 17" 4.5 x 17"Amount of shots to complete weld with 1" on each side of readable film: 68% of weld: 6.0384" 153.3754 mmHole penetrameters are adjacent to the weld and Wire penetrameters are parallel to the weld.

Page 2 of 2

Page 184: NDT Code Book Made Easy

PENETRAMETER SELECTIONNote: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Wire: 0.032 Esn. Wire: B1 or C6 S/S Hole: 35

F/S Wire: 0.025 Esn. Wire: B2 F/S Hole: 30Welds with reinforcement: S/S Wire: 0.040 Esn. Wire: C5 S/S Hole: 40

F/S Wire: 0.032 Esn. Wire: B1 or C6 F/S Hole: 35Maximum allowable reinforcement: 0.0625"/per sideMaximum reinforcement with DWE/SWV: 0.125" Total of walls + reinforcement: 3.749" 95.2246 mmMaximum reinforcement with DWE/DWV: 0.125" Total of walls + reinforcement: 3.749" 95.2246 mmMaximum reinforcement with SWE/SWV: 0.0625" Total of wall + reinforcement: 1.8745" 47.6123 mm

INADEQUATE PENETRATION WITHOUT HIGH LOWMaximum length of individual indication of IP : 1 inch or 25mmMaximum length of IP in 8% of weld: N/A since total weld exceeds 12 inchesMaximum length of indications in any continuous 12" length of weld: 1" 25 mm

INADEQUATE PENETRATION DUE TO HIGH LOWMaximum length of individual indication of IPD: 2 inches or 50mmMaximum length of indications of IPD in any continuous 12" length of weld: 3" 75 mm

INADEQUATE CROSS PENETRATIONMaximum length of an individual indication of ICP: 2 inches or 50mmMaximum length of indications of ICP in any continuous 12" length of weld: 2" 50 mm

INCOMPLETE FUSIONMaximum length of an individual indication of IF: 1 inch or 25mmMaximum length of IF in 8% of weld: N/A since total weld exceeds 12 inchesMaximum length of indications of IF in any continuous 12" length of weld: 1" 25 mm

INCOMPLETE FUSION DUE TO COLD LAPMaximum length of individual indications of IFD: 2 inches or 50mmMaximum length of IFD in 8% of weld: 153.3754 mmMaximum length of indications of IFD in any continuous 12" length of weld: 2" 25 mm

INTERNAL CONCAVITY Any length of IC is acceptable, provided the density of the radiographic image of the internal concavity does not exceed that of the thinnest adjacent parent material. For areas that exceed the density of thethinnest adjacent parent material, the criteria for burn through are applicable.

BURN - THROUGHMaximum dimension of BT's image : unacceptable if it exceeds that of the thinnest adjacent parent metal.Maximum dimension of BT: 1/4" or 6mmMaximum dimension is unacceptable if: it exceeds the thinner of the nonnal wall thickness joined, and the density

of the BT's image exceeds that of the thinnest adjacent parent material.The sum of the max dimensions of separate BBT's whose image density exceeds that of the thinnest adjacent parentmaterial exceeds 1/2 inch or 13mm in any continuous 12" length of weld or the total weld length(whichever is less).

API - 110424" s/120 - 1.812" Wall

Page 1 of 2

Page 185: NDT Code Book Made Easy

API - 110424" s/120 - 1.812" Wall

SLAG INCLUSIONSElongated slag inclusions (ESI)Maximum length of an ESI: 2 inches or 50mmParallel ESI indications (Wagon Tracks) shall be considered a single indication unless the width of either of them exceed1/32" or 0.8mm. In that event they shall be considered separate indications.Maximum length of ESI indications in any continuous 12" length of weld: 2" 50 mmMaximum width of an individual ESI indication: 1/16" or 1.6mmIsolated slag inclusions (ISI)Maximum length of ISI indications in any continuous 12" length of weld: 1/2" 13 mmMaximum width of an ISI indication: 1/8" or 3mmMaximum length of ESI and ISI in 8% of weld: 153.3754 mm

POROSITY Individual or Scattered Porosity.Maximum size of an individual pore: 1/8" or 3mmThe size of an individual pore exceeds 25% of the thinner of the nonimal wall thickness joined.The distribution of scattered porosity exceeds the concentration permitted in Figures 19 or 20.Cluster Porosity (CP)Maximum diameter of the cluster: 1/2 inch or 13mmMaximum length of CP indications in any continuous 12" length of weweld: 1/2" 13 mmMaximum length of an individual pore within a cluster: 1/16 inch or 2mmHollow Bead Porosity (HB)Maximum length of an individual indication of HB: 1/2 inch or 13mmMaximum length of HB indications in any continuous 12" length of weld: 2" 50 mmMaximum length of HB in 8% of weld: 153.3754 mmNOTE: The weld is unacceptable if individual indications of HB, each greater than 1/4 inch or 6mm in length, are seperated by less than 2 inches or 50 mm.

CRACKSNote: Any crack which is not a shallow crater crack or star crack is unacceptable.Maximum length of shallow crater cracks or star cracks: 5/32 inch or 4mm

UNDERCUTTINGUndercutting adjacent to the cover pass (EU) and Undercutting adjacent to the root pass (IU)Maximum length of EU and IU indications (in any combination) in a 12 inch length of weld: 2" 50 mmMaximum length of EU and IU indications: 12.58" 319.5320 mm (This value is 1/6 th of the total weld length)

ACCUMULATION OF IMPERFECTIONSMaximum length of AI indications in any continuous 12 inch or 300 mm length of weld: 2" 50 mmMaximum length of AI indications of 8% of weld: 153.3754 mm

RADIOGRAPHIC INFOPipe O.D. in inches: 24.00"Amount of Penetrameters required for each shot: 1 penetrameter 1" from the end of film and 1 penny in the center.Total weld length: 75.48" 1917.1920 mmCassette size to complete weld in most efficient way: 3.5 x 17" 4.5 x 17"Amount of shots to complete weld with 1" on each side of readable film: 68% of weld: 6.0384" 153.3754 mmHole penetrameters are adjacent to the weld and Wire penetrameters are parallel to the weld.

Page 2 of 2

Page 186: NDT Code Book Made Easy

PENETRAMETER SELECTIONNote: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Wire: 0.040 Esn. Wire: C5 S/S Hole: 40

F/S Wire: 0.032 Esn. Wire: B1 or C6 F/S Hole: 35Welds with reinforcement: S/S Wire: 0.050 Esn. Wire: C4 S/S Hole: 50

F/S Wire: 0.040 Esn. Wire: C5 F/S Hole: 40Maximum allowable reinforcement: 0.0625"/per sideMaximum reinforcement with DWE/SWV: 0.125" Total of walls + reinforcement: 4.249" 107.9246 mmMaximum reinforcement with DWE/DWV: 0.125" Total of walls + reinforcement: 4.249" 107.9246 mmMaximum reinforcement with SWE/SWV: 0.0625" Total of wall + reinforcement: 2.1245" 53.9623 mm

INADEQUATE PENETRATION WITHOUT HIGH LOWMaximum length of individual indication of IP : 1 inch or 25mmMaximum length of IP in 8% of weld: N/A since total weld exceeds 12 inchesMaximum length of indications in any continuous 12" length of weld: 1" 25 mm

INADEQUATE PENETRATION DUE TO HIGH LOWMaximum length of individual indication of IPD: 2 inches or 50mmMaximum length of indications of IPD in any continuous 12" length of weld: 3" 75 mm

INADEQUATE CROSS PENETRATIONMaximum length of an individual indication of ICP: 2 inches or 50mmMaximum length of indications of ICP in any continuous 12" length of weld: 2" 50 mm

INCOMPLETE FUSIONMaximum length of an individual indication of IF: 1 inch or 25mmMaximum length of IF in 8% of weld: N/A since total weld exceeds 12 inchesMaximum length of indications of IF in any continuous 12" length of weld: 1" 25 mm

INCOMPLETE FUSION DUE TO COLD LAPMaximum length of individual indications of IFD: 2 inches or 50mmMaximum length of IFD in 8% of weld: 153.3754 mmMaximum length of indications of IFD in any continuous 12" length of weld: 2" 25 mm

INTERNAL CONCAVITY Any length of IC is acceptable, provided the density of the radiographic image of the internal concavity does not exceed that of the thinnest adjacent parent material. For areas that exceed the density of thethinnest adjacent parent material, the criteria for burn through are applicable.

BURN - THROUGHMaximum dimension of BT's image : unacceptable if it exceeds that of the thinnest adjacent parent metal.Maximum dimension of BT: 1/4" or 6mmMaximum dimension is unacceptable if: it exceeds the thinner of the nonnal wall thickness joined, and the density

of the BT's image exceeds that of the thinnest adjacent parent material.The sum of the max dimensions of separate BBT's whose image density exceeds that of the thinnest adjacent parentmaterial exceeds 1/2 inch or 13mm in any continuous 12" length of weld or the total weld length(whichever is less).

API - 110424" s/140 - 2.062" Wall

Page 1 of 2

Page 187: NDT Code Book Made Easy

API - 110424" s/140 - 2.062" Wall

SLAG INCLUSIONSElongated slag inclusions (ESI)Maximum length of an ESI: 2 inches or 50mmParallel ESI indications (Wagon Tracks) shall be considered a single indication unless the width of either of them exceed1/32" or 0.8mm. In that event they shall be considered separate indications.Maximum length of ESI indications in any continuous 12" length of weld: 2" 50 mmMaximum width of an individual ESI indication: 1/16" or 1.6mmIsolated slag inclusions (ISI)Maximum length of ISI indications in any continuous 12" length of weld: 1/2" 13 mmMaximum width of an ISI indication: 1/8" or 3mmMaximum length of ESI and ISI in 8% of weld: 153.3754 mm

POROSITY Individual or Scattered Porosity.Maximum size of an individual pore: 1/8" or 3mmThe size of an individual pore exceeds 25% of the thinner of the nonimal wall thickness joined.The distribution of scattered porosity exceeds the concentration permitted in Figures 19 or 20.Cluster Porosity (CP)Maximum diameter of the cluster: 1/2 inch or 13mmMaximum length of CP indications in any continuous 12" length of weweld: 1/2" 13 mmMaximum length of an individual pore within a cluster: 1/16 inch or 2mmHollow Bead Porosity (HB)Maximum length of an individual indication of HB: 1/2 inch or 13mmMaximum length of HB indications in any continuous 12" length of weld: 2" 50 mmMaximum length of HB in 8% of weld: 153.3754 mmNOTE: The weld is unacceptable if individual indications of HB, each greater than 1/4 inch or 6mm in length, are seperated by less than 2 inches or 50 mm.

CRACKSNote: Any crack which is not a shallow crater crack or star crack is unacceptable.Maximum length of shallow crater cracks or star cracks: 5/32 inch or 4mm

UNDERCUTTINGUndercutting adjacent to the cover pass (EU) and Undercutting adjacent to the root pass (IU)Maximum length of EU and IU indications (in any combination) in a 12 inch length of weld: 2" 50 mmMaximum length of EU and IU indications: 12.58" 319.5320 mm (This value is 1/6 th of the total weld length)

ACCUMULATION OF IMPERFECTIONSMaximum length of AI indications in any continuous 12 inch or 300 mm length of weld: 2" 50 mmMaximum length of AI indications of 8% of weld: 153.3754 mm

RADIOGRAPHIC INFOPipe O.D. in inches: 24.00"Amount of Penetrameters required for each shot: 1 penetrameter 1" from the end of film and 1 penny in the center.Total weld length: 75.48" 1917.1920 mmCassette size to complete weld in most efficient way: 3.5 x 17" 4.5 x 17"Amount of shots to complete weld with 1" on each side of readable film: 68% of weld: 6.0384" 153.3754 mmHole penetrameters are adjacent to the weld and Wire penetrameters are parallel to the weld.

Page 2 of 2

Page 188: NDT Code Book Made Easy

PENETRAMETER SELECTIONNote: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Wire: 0.040 Esn. Wire: C5 S/S Hole: 40

F/S Wire: 0.032 Esn. Wire: B1 or C6 F/S Hole: 35Welds with reinforcement: S/S Wire: 0.050 Esn. Wire: C4 S/S Hole: 50

F/S Wire: 0.040 Esn. Wire: C5 F/S Hole: 40Maximum allowable reinforcement: 0.0625"/per sideMaximum reinforcement with DWE/SWV: 0.125" Total of walls + reinforcement: 4.813" 122.2502 mmMaximum reinforcement with DWE/DWV: 0.125" Total of walls + reinforcement: 4.813" 122.2502 mmMaximum reinforcement with SWE/SWV: 0.0625" Total of wall + reinforcement: 2.4065" 61.1251 mm

INADEQUATE PENETRATION WITHOUT HIGH LOWMaximum length of individual indication of IP : 1 inch or 25mmMaximum length of IP in 8% of weld: N/A since total weld exceeds 12 inchesMaximum length of indications in any continuous 12" length of weld: 1" 25 mm

INADEQUATE PENETRATION DUE TO HIGH LOWMaximum length of individual indication of IPD: 2 inches or 50mmMaximum length of indications of IPD in any continuous 12" length of weld: 3" 75 mm

INADEQUATE CROSS PENETRATIONMaximum length of an individual indication of ICP: 2 inches or 50mmMaximum length of indications of ICP in any continuous 12" length of weld: 2" 50 mm

INCOMPLETE FUSIONMaximum length of an individual indication of IF: 1 inch or 25mmMaximum length of IF in 8% of weld: N/A since total weld exceeds 12 inchesMaximum length of indications of IF in any continuous 12" length of weld: 1" 25 mm

INCOMPLETE FUSION DUE TO COLD LAPMaximum length of individual indications of IFD: 2 inches or 50mmMaximum length of IFD in 8% of weld: 153.3754 mmMaximum length of indications of IFD in any continuous 12" length of weld: 2" 25 mm

INTERNAL CONCAVITY Any length of IC is acceptable, provided the density of the radiographic image of the internal concavity does not exceed that of the thinnest adjacent parent material. For areas that exceed the density of thethinnest adjacent parent material, the criteria for burn through are applicable.

BURN - THROUGHMaximum dimension of BT's image : unacceptable if it exceeds that of the thinnest adjacent parent metal.Maximum dimension of BT: 1/4" or 6mmMaximum dimension is unacceptable if: it exceeds the thinner of the nonnal wall thickness joined, and the density

of the BT's image exceeds that of the thinnest adjacent parent material.The sum of the max dimensions of separate BBT's whose image density exceeds that of the thinnest adjacent parentmaterial exceeds 1/2 inch or 13mm in any continuous 12" length of weld or the total weld length(whichever is less).

API - 110424" s/160 - 2.344" Wall

Page 1 of 2

Page 189: NDT Code Book Made Easy

API - 110424" s/160 - 2.344" Wall

SLAG INCLUSIONSElongated slag inclusions (ESI)Maximum length of an ESI: 2 inches or 50mmParallel ESI indications (Wagon Tracks) shall be considered a single indication unless the width of either of them exceed1/32" or 0.8mm. In that event they shall be considered separate indications.Maximum length of ESI indications in any continuous 12" length of weld: 2" 50 mmMaximum width of an individual ESI indication: 1/16" or 1.6mmIsolated slag inclusions (ISI)Maximum length of ISI indications in any continuous 12" length of weld: 1/2" 13 mmMaximum width of an ISI indication: 1/8" or 3mmMaximum length of ESI and ISI in 8% of weld: 153.3754 mm

POROSITY Individual or Scattered Porosity.Maximum size of an individual pore: 1/8" or 3mmThe size of an individual pore exceeds 25% of the thinner of the nonimal wall thickness joined.The distribution of scattered porosity exceeds the concentration permitted in Figures 19 or 20.Cluster Porosity (CP)Maximum diameter of the cluster: 1/2 inch or 13mmMaximum length of CP indications in any continuous 12" length of weweld: 1/2" 13 mmMaximum length of an individual pore within a cluster: 1/16 inch or 2mmHollow Bead Porosity (HB)Maximum length of an individual indication of HB: 1/2 inch or 13mmMaximum length of HB indications in any continuous 12" length of weld: 2" 50 mmMaximum length of HB in 8% of weld: 153.3754 mmNOTE: The weld is unacceptable if individual indications of HB, each greater than 1/4 inch or 6mm in length, are seperated by less than 2 inches or 50 mm.

CRACKSNote: Any crack which is not a shallow crater crack or star crack is unacceptable.Maximum length of shallow crater cracks or star cracks: 5/32 inch or 4mm

UNDERCUTTINGUndercutting adjacent to the cover pass (EU) and Undercutting adjacent to the root pass (IU)Maximum length of EU and IU indications (in any combination) in a 12 inch length of weld: 2" 50 mmMaximum length of EU and IU indications: 12.58" 319.5320 mm (This value is 1/6 th of the total weld length)

ACCUMULATION OF IMPERFECTIONSMaximum length of AI indications in any continuous 12 inch or 300 mm length of weld: 2" 50 mmMaximum length of AI indications of 8% of weld: 153.3754 mm

RADIOGRAPHIC INFOPipe O.D. in inches: 24.00"Amount of Penetrameters required for each shot: 1 penetrameter 1" from the end of film and 1 penny in the center.Total weld length: 75.48" 1917.1920 mmCassette size to complete weld in most efficient way: 3.5 x 17" 4.5 x 17"Amount of shots to complete weld with 1" on each side of readable film: 68% of weld: 6.0384" 153.3754 mmHole penetrameters are adjacent to the weld and Wire penetrameters are parallel to the weld.

Page 2 of 2

Page 190: NDT Code Book Made Easy

PENETRAMETER SELECTIONNote: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Wire: 0.010 Esn. Wire: A1 or B6 S/S Hole: 15

F/S Wire: 0.008 Esn. Wire: A2 F/S Hole: 12Welds with reinforcement: S/S Wire: 0.013 Esn. Wire: B5 S/S Hole: 17

F/S Wire: 0.010 Esn. Wire: A1 or B6 F/S Hole: 15Maximum allowable reinforcement: 0.0625"/per sideMaximum reinforcement with DWE/SWV: 0.125" Total of walls + reinforcement: 0.749" 19.0246 mmMaximum reinforcement with DWE/DWV: 0.125" Total of walls + reinforcement: 0.749" 19.0246 mmMaximum reinforcement with SWE/SWV: 0.0625" Total of wall + reinforcement: 0.3745" 9.5123 mm

INADEQUATE PENETRATION WITHOUT HIGH LOWMaximum length of individual indication of IP : 1 inch or 25mmMaximum length of IP in 8% of weld: N/A since total weld exceeds 12 inchesMaximum length of indications in any continuous 12" length of weld: 1" 25 mm

INADEQUATE PENETRATION DUE TO HIGH LOWMaximum length of individual indication of IPD: 2 inches or 50mmMaximum length of indications of IPD in any continuous 12" length of weld: 3" 75 mm

INADEQUATE CROSS PENETRATIONMaximum length of an individual indication of ICP: 2 inches or 50mmMaximum length of indications of ICP in any continuous 12" length of weld: 2" 50 mm

INCOMPLETE FUSIONMaximum length of an individual indication of IF: 1 inch or 25mmMaximum length of IF in 8% of weld: N/A since total weld exceeds 12 inchesMaximum length of indications of IF in any continuous 12" length of weld: 1" 25 mm

INCOMPLETE FUSION DUE TO COLD LAPMaximum length of individual indications of IFD: 2 inches or 50mmMaximum length of IFD in 8% of weld: 166.1566 mmMaximum length of indications of IFD in any continuous 12" length of weld: 2" 25 mm

INTERNAL CONCAVITY Any length of IC is acceptable, provided the density of the radiographic image of the internal concavity does not exceed that of the thinnest adjacent parent material. For areas that exceed the density of thethinnest adjacent parent material, the criteria for burn through are applicable.

BURN - THROUGHMaximum dimension of BT's image : unacceptable if it exceeds that of the thinnest adjacent parent metal.Maximum dimension of BT: 1/4" or 6mmMaximum dimension is unacceptable if: it exceeds the thinner of the nonnal wall thickness joined, and the density

of the BT's image exceeds that of the thinnest adjacent parent material.The sum of the max dimensions of separate BBT's whose image density exceeds that of the thinnest adjacent parentmaterial exceeds 1/2 inch or 13mm in any continuous 12" length of weld or the total weld length(whichever is less).

API - 110426" s/10 - 0.312" Wall

Page 1 of 2

Page 191: NDT Code Book Made Easy

API - 110426" s/10 - 0.312" Wall

SLAG INCLUSIONSElongated slag inclusions (ESI)Maximum length of an ESI: 2 inches or 50mmParallel ESI indications (Wagon Tracks) shall be considered a single indication unless the width of either of them exceed1/32" or 0.8mm. In that event they shall be considered separate indications.Maximum length of ESI indications in any continuous 12" length of weld: 2" 50 mmMaximum width of an individual ESI indication: 1/16" or 1.6mmIsolated slag inclusions (ISI)Maximum length of ISI indications in any continuous 12" length of weld: 1/2" 13 mmMaximum width of an ISI indication: 1/8" or 3mmMaximum length of ESI and ISI in 8% of weld: 166.1566 mm

POROSITY Individual or Scattered Porosity.Maximum size of an individual pore: 1/8" or 3mmThe size of an individual pore exceeds 25% of the thinner of the nonimal wall thickness joined.The distribution of scattered porosity exceeds the concentration permitted in Figures 19 or 20.Cluster Porosity (CP)Maximum diameter of the cluster: 1/2 inch or 13mmMaximum length of CP indications in any continuous 12" length of weweld: 1/2" 13 mmMaximum length of an individual pore within a cluster: 1/16 inch or 2mmHollow Bead Porosity (HB)Maximum length of an individual indication of HB: 1/2 inch or 13mmMaximum length of HB indications in any continuous 12" length of weld: 2" 50 mmMaximum length of HB in 8% of weld: 166.1566 mmNOTE: The weld is unacceptable if individual indications of HB, each greater than 1/4 inch or 6mm in length, are seperated by less than 2 inches or 50 mm.

CRACKSNote: Any crack which is not a shallow crater crack or star crack is unacceptable.Maximum length of shallow crater cracks or star cracks: 5/32 inch or 4mm

UNDERCUTTINGUndercutting adjacent to the cover pass (EU) and Undercutting adjacent to the root pass (IU)Maximum length of EU and IU indications (in any combination) in a 12 inch length of weld: 2" 50 mmMaximum length of EU and IU indications: 13.6283" 346.1588 mm (This value is 1/6 th of the total weld length)

ACCUMULATION OF IMPERFECTIONSMaximum length of AI indications in any continuous 12 inch or 300 mm length of weld: 2" 50 mmMaximum length of AI indications of 8% of weld: 166.1566 mm

RADIOGRAPHIC INFOPipe O.D. in inches: 26.00"Amount of Penetrameters required for each shot: 1 penetrameter 1" from the end of film and 1 penny in the center.Total weld length: 81.77" 2076.9580 mmCassette size to complete weld in most efficient way: 3.5 x 17" 4.5 x 17"Amount of shots to complete weld with 1" on each side of readable film: 68% of weld: 6.5416" 166.1566 mmHole penetrameters are adjacent to the weld and Wire penetrameters are parallel to the weld.

Page 2 of 2

Page 192: NDT Code Book Made Easy

PENETRAMETER SELECTIONNote: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Wire: 0.010 Esn. Wire: A1 or B6 S/S Hole: 15

F/S Wire: 0.008 Esn. Wire: A2 F/S Hole: 12Welds with reinforcement: S/S Wire: 0.013 Esn. Wire: B5 S/S Hole: 17

F/S Wire: 0.010 Esn. Wire: A1 or B6 F/S Hole: 15Maximum allowable reinforcement: 0.0625"/per sideMaximum reinforcement with DWE/SWV: 0.125" Total of walls + reinforcement: 0.875" 22.2250 mmMaximum reinforcement with DWE/DWV: 0.125" Total of walls + reinforcement: 0.875" 22.2250 mmMaximum reinforcement with SWE/SWV: 0.0625" Total of wall + reinforcement: 0.4375" 11.1125 mm

INADEQUATE PENETRATION WITHOUT HIGH LOWMaximum length of individual indication of IP : 1 inch or 25mmMaximum length of IP in 8% of weld: N/A since total weld exceeds 12 inchesMaximum length of indications in any continuous 12" length of weld: 1" 25 mm

INADEQUATE PENETRATION DUE TO HIGH LOWMaximum length of individual indication of IPD: 2 inches or 50mmMaximum length of indications of IPD in any continuous 12" length of weld: 3" 75 mm

INADEQUATE CROSS PENETRATIONMaximum length of an individual indication of ICP: 2 inches or 50mmMaximum length of indications of ICP in any continuous 12" length of weld: 2" 50 mm

INCOMPLETE FUSIONMaximum length of an individual indication of IF: 1 inch or 25mmMaximum length of IF in 8% of weld: N/A since total weld exceeds 12 inchesMaximum length of indications of IF in any continuous 12" length of weld: 1" 25 mm

INCOMPLETE FUSION DUE TO COLD LAPMaximum length of individual indications of IFD: 2 inches or 50mmMaximum length of IFD in 8% of weld: 166.1566 mmMaximum length of indications of IFD in any continuous 12" length of weld: 2" 25 mm

INTERNAL CONCAVITY Any length of IC is acceptable, provided the density of the radiographic image of the internal concavity does not exceed that of the thinnest adjacent parent material. For areas that exceed the density of thethinnest adjacent parent material, the criteria for burn through are applicable.

BURN - THROUGHMaximum dimension of BT's image : unacceptable if it exceeds that of the thinnest adjacent parent metal.Maximum dimension of BT: 1/4" or 6mmMaximum dimension is unacceptable if: it exceeds the thinner of the nonnal wall thickness joined, and the density

of the BT's image exceeds that of the thinnest adjacent parent material.The sum of the max dimensions of separate BBT's whose image density exceeds that of the thinnest adjacent parentmaterial exceeds 1/2 inch or 13mm in any continuous 12" length of weld or the total weld length(whichever is less).

API - 110426" Standard - 0.375" Wall

Page 1 of 2

Page 193: NDT Code Book Made Easy

API - 110426" Standard - 0.375" Wall

SLAG INCLUSIONSElongated slag inclusions (ESI)Maximum length of an ESI: 2 inches or 50mmParallel ESI indications (Wagon Tracks) shall be considered a single indication unless the width of either of them exceed1/32" or 0.8mm. In that event they shall be considered separate indications.Maximum length of ESI indications in any continuous 12" length of weld: 2" 50 mmMaximum width of an individual ESI indication: 1/16" or 1.6mmIsolated slag inclusions (ISI)Maximum length of ISI indications in any continuous 12" length of weld: 1/2" 13 mmMaximum width of an ISI indication: 1/8" or 3mmMaximum length of ESI and ISI in 8% of weld: 166.1566 mm

POROSITY Individual or Scattered Porosity.Maximum size of an individual pore: 1/8" or 3mmThe size of an individual pore exceeds 25% of the thinner of the nonimal wall thickness joined.The distribution of scattered porosity exceeds the concentration permitted in Figures 19 or 20.Cluster Porosity (CP)Maximum diameter of the cluster: 1/2 inch or 13mmMaximum length of CP indications in any continuous 12" length of weweld: 1/2" 13 mmMaximum length of an individual pore within a cluster: 1/16 inch or 2mmHollow Bead Porosity (HB)Maximum length of an individual indication of HB: 1/2 inch or 13mmMaximum length of HB indications in any continuous 12" length of weld: 2" 50 mmMaximum length of HB in 8% of weld: 166.1566 mmNOTE: The weld is unacceptable if individual indications of HB, each greater than 1/4 inch or 6mm in length, are seperated by less than 2 inches or 50 mm.

CRACKSNote: Any crack which is not a shallow crater crack or star crack is unacceptable.Maximum length of shallow crater cracks or star cracks: 5/32 inch or 4mm

UNDERCUTTINGUndercutting adjacent to the cover pass (EU) and Undercutting adjacent to the root pass (IU)Maximum length of EU and IU indications (in any combination) in a 12 inch length of weld: 2" 50 mmMaximum length of EU and IU indications: 13.6283" 346.1588 mm (This value is 1/6 th of the total weld length)

ACCUMULATION OF IMPERFECTIONSMaximum length of AI indications in any continuous 12 inch or 300 mm length of weld: 2" 50 mmMaximum length of AI indications of 8% of weld: 166.1566 mm

RADIOGRAPHIC INFOPipe O.D. in inches: 26.00"Amount of Penetrameters required for each shot: 1 penetrameter 1" from the end of film and 1 penny in the center.Total weld length: 81.77" 2076.9580 mmCassette size to complete weld in most efficient way: 3.5 x 17" 4.5 x 17"Amount of shots to complete weld with 1" on each side of readable film: 68% of weld: 6.5416" 166.1566 mmHole penetrameters are adjacent to the weld and Wire penetrameters are parallel to the weld.

Page 2 of 2

Page 194: NDT Code Book Made Easy

PENETRAMETER SELECTIONNote: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Wire: 0.013 Esn. Wire: B5 S/S Hole: 17

F/S Wire: 0.010 Esn. Wire: A1 or B6 F/S Hole: 15Welds with reinforcement: S/S Wire: 0.016 Esn. Wire: B4 S/S Hole: 20

F/S Wire: 0.013 Esn. Wire: B5 F/S Hole: 17Maximum allowable reinforcement: 0.0625"/per sideMaximum reinforcement with DWE/SWV: 0.125" Total of walls + reinforcement: 1.125" 28.5750 mmMaximum reinforcement with DWE/DWV: 0.125" Total of walls + reinforcement: 1.125" 28.5750 mmMaximum reinforcement with SWE/SWV: 0.0625" Total of wall + reinforcement: 0.5625" 14.2875 mm

INADEQUATE PENETRATION WITHOUT HIGH LOWMaximum length of individual indication of IP : 1 inch or 25mmMaximum length of IP in 8% of weld: N/A since total weld exceeds 12 inchesMaximum length of indications in any continuous 12" length of weld: 1" 25 mm

INADEQUATE PENETRATION DUE TO HIGH LOWMaximum length of individual indication of IPD: 2 inches or 50mmMaximum length of indications of IPD in any continuous 12" length of weld: 3" 75 mm

INADEQUATE CROSS PENETRATIONMaximum length of an individual indication of ICP: 2 inches or 50mmMaximum length of indications of ICP in any continuous 12" length of weld: 2" 50 mm

INCOMPLETE FUSIONMaximum length of an individual indication of IF: 1 inch or 25mmMaximum length of IF in 8% of weld: N/A since total weld exceeds 12 inchesMaximum length of indications of IF in any continuous 12" length of weld: 1" 25 mm

INCOMPLETE FUSION DUE TO COLD LAPMaximum length of individual indications of IFD: 2 inches or 50mmMaximum length of IFD in 8% of weld: 166.1566 mmMaximum length of indications of IFD in any continuous 12" length of weld: 2" 25 mm

INTERNAL CONCAVITY Any length of IC is acceptable, provided the density of the radiographic image of the internal concavity does not exceed that of the thinnest adjacent parent material. For areas that exceed the density of thethinnest adjacent parent material, the criteria for burn through are applicable.

BURN - THROUGHMaximum dimension of BT's image : unacceptable if it exceeds that of the thinnest adjacent parent metal.Maximum dimension of BT: 1/4" or 6mmMaximum dimension is unacceptable if: it exceeds the thinner of the nonnal wall thickness joined, and the density

of the BT's image exceeds that of the thinnest adjacent parent material.The sum of the max dimensions of separate BBT's whose image density exceeds that of the thinnest adjacent parentmaterial exceeds 1/2 inch or 13mm in any continuous 12" length of weld or the total weld length(whichever is less).

API - 110426" Extra Strong - 0.500" Wall

Page 1 of 2

Page 195: NDT Code Book Made Easy

API - 110426" Extra Strong - 0.500" Wall

SLAG INCLUSIONSElongated slag inclusions (ESI)Maximum length of an ESI: 2 inches or 50mmParallel ESI indications (Wagon Tracks) shall be considered a single indication unless the width of either of them exceed1/32" or 0.8mm. In that event they shall be considered separate indications.Maximum length of ESI indications in any continuous 12" length of weld: 2" 50 mmMaximum width of an individual ESI indication: 1/16" or 1.6mmIsolated slag inclusions (ISI)Maximum length of ISI indications in any continuous 12" length of weld: 1/2" 13 mmMaximum width of an ISI indication: 1/8" or 3mmMaximum length of ESI and ISI in 8% of weld: 166.1566 mm

POROSITY Individual or Scattered Porosity.Maximum size of an individual pore: 1/8" or 3mmThe size of an individual pore exceeds 25% of the thinner of the nonimal wall thickness joined.The distribution of scattered porosity exceeds the concentration permitted in Figures 19 or 20.Cluster Porosity (CP)Maximum diameter of the cluster: 1/2 inch or 13mmMaximum length of CP indications in any continuous 12" length of weweld: 1/2" 13 mmMaximum length of an individual pore within a cluster: 1/16 inch or 2mmHollow Bead Porosity (HB)Maximum length of an individual indication of HB: 1/2 inch or 13mmMaximum length of HB indications in any continuous 12" length of weld: 2" 50 mmMaximum length of HB in 8% of weld: 166.1566 mmNOTE: The weld is unacceptable if individual indications of HB, each greater than 1/4 inch or 6mm in length, are seperated by less than 2 inches or 50 mm.

CRACKSNote: Any crack which is not a shallow crater crack or star crack is unacceptable.Maximum length of shallow crater cracks or star cracks: 5/32 inch or 4mm

UNDERCUTTINGUndercutting adjacent to the cover pass (EU) and Undercutting adjacent to the root pass (IU)Maximum length of EU and IU indications (in any combination) in a 12 inch length of weld: 2" 50 mmMaximum length of EU and IU indications: 13.6283" 346.1588 mm (This value is 1/6 th of the total weld length)

ACCUMULATION OF IMPERFECTIONSMaximum length of AI indications in any continuous 12 inch or 300 mm length of weld: 2" 50 mmMaximum length of AI indications of 8% of weld: 166.1566 mm

RADIOGRAPHIC INFOPipe O.D. in inches: 26.00"Amount of Penetrameters required for each shot: 1 penetrameter 1" from the end of film and 1 penny in the center.Total weld length: 81.77" 2076.9580 mmCassette size to complete weld in most efficient way: 3.5 x 17" 4.5 x 17"Amount of shots to complete weld with 1" on each side of readable film: 68% of weld: 6.5416" 166.1566 mmHole penetrameters are adjacent to the weld and Wire penetrameters are parallel to the weld.

Page 2 of 2

Page 196: NDT Code Book Made Easy

PENETRAMETER SELECTIONNote: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Wire: 0.010 Esn. Wire: A1 or B6 S/S Hole: 15

F/S Wire: 0.008 Esn. Wire: A2 F/S Hole: 12Welds with reinforcement: S/S Wire: 0.013 Esn. Wire: B5 S/S Hole: 17

F/S Wire: 0.010 Esn. Wire: A1 or B6 F/S Hole: 15Maximum allowable reinforcement: 0.0625"/per sideMaximum reinforcement with DWE/SWV: 0.125" Total of walls + reinforcement: 0.749" 19.0246 mmMaximum reinforcement with DWE/DWV: 0.125" Total of walls + reinforcement: 0.749" 19.0246 mmMaximum reinforcement with SWE/SWV: 0.0625" Total of wall + reinforcement: 0.3745" 9.5123 mm

INADEQUATE PENETRATION WITHOUT HIGH LOWMaximum length of individual indication of IP : 1 inch or 25mmMaximum length of IP in 8% of weld: N/A since total weld exceeds 12 inchesMaximum length of indications in any continuous 12" length of weld: 1" 25 mm

INADEQUATE PENETRATION DUE TO HIGH LOWMaximum length of individual indication of IPD: 2 inches or 50mmMaximum length of indications of IPD in any continuous 12" length of weld: 3" 75 mm

INADEQUATE CROSS PENETRATIONMaximum length of an individual indication of ICP: 2 inches or 50mmMaximum length of indications of ICP in any continuous 12" length of weld: 2" 50 mm

INCOMPLETE FUSIONMaximum length of an individual indication of IF: 1 inch or 25mmMaximum length of IF in 8% of weld: N/A since total weld exceeds 12 inchesMaximum length of indications of IF in any continuous 12" length of weld: 1" 25 mm

INCOMPLETE FUSION DUE TO COLD LAPMaximum length of individual indications of IFD: 2 inches or 50mmMaximum length of IFD in 8% of weld: 230.0630 mmMaximum length of indications of IFD in any continuous 12" length of weld: 2" 25 mm

INTERNAL CONCAVITY Any length of IC is acceptable, provided the density of the radiographic image of the internal concavity does not exceed that of the thinnest adjacent parent material. For areas that exceed the density of thethinnest adjacent parent material, the criteria for burn through are applicable.

BURN - THROUGHMaximum dimension of BT's image : unacceptable if it exceeds that of the thinnest adjacent parent metal.Maximum dimension of BT: 1/4" or 6mmMaximum dimension is unacceptable if: it exceeds the thinner of the nonnal wall thickness joined, and the density

of the BT's image exceeds that of the thinnest adjacent parent material.The sum of the max dimensions of separate BBT's whose image density exceeds that of the thinnest adjacent parentmaterial exceeds 1/2 inch or 13mm in any continuous 12" length of weld or the total weld length(whichever is less).

API - 110436" s/10 - 0.312" Wall

Page 1 of 2

Page 197: NDT Code Book Made Easy

API - 110436" s/10 - 0.312" Wall

SLAG INCLUSIONSElongated slag inclusions (ESI)Maximum length of an ESI: 2 inches or 50mmParallel ESI indications (Wagon Tracks) shall be considered a single indication unless the width of either of them exceed1/32" or 0.8mm. In that event they shall be considered separate indications.Maximum length of ESI indications in any continuous 12" length of weld: 2" 50 mmMaximum width of an individual ESI indication: 1/16" or 1.6mmIsolated slag inclusions (ISI)Maximum length of ISI indications in any continuous 12" length of weld: 1/2" 13 mmMaximum width of an ISI indication: 1/8" or 3mmMaximum length of ESI and ISI in 8% of weld: 230.0630 mm

POROSITY Individual or Scattered Porosity.Maximum size of an individual pore: 1/8" or 3mmThe size of an individual pore exceeds 25% of the thinner of the nonimal wall thickness joined.The distribution of scattered porosity exceeds the concentration permitted in Figures 19 or 20.Cluster Porosity (CP)Maximum diameter of the cluster: 1/2 inch or 13mmMaximum length of CP indications in any continuous 12" length of weweld: 1/2" 13 mmMaximum length of an individual pore within a cluster: 1/16 inch or 2mmHollow Bead Porosity (HB)Maximum length of an individual indication of HB: 1/2 inch or 13mmMaximum length of HB indications in any continuous 12" length of weld: 2" 50 mmMaximum length of HB in 8% of weld: 230.0630 mmNOTE: The weld is unacceptable if individual indications of HB, each greater than 1/4 inch or 6mm in length, are seperated by less than 2 inches or 50 mm.

CRACKSNote: Any crack which is not a shallow crater crack or star crack is unacceptable.Maximum length of shallow crater cracks or star cracks: 5/32 inch or 4mm

UNDERCUTTINGUndercutting adjacent to the cover pass (EU) and Undercutting adjacent to the root pass (IU)Maximum length of EU and IU indications (in any combination) in a 12 inch length of weld: 2" 50 mmMaximum length of EU and IU indications: 18.87" 479.2980 mm (This value is 1/6 th of the total weld length)

ACCUMULATION OF IMPERFECTIONSMaximum length of AI indications in any continuous 12 inch or 300 mm length of weld: 2" 50 mmMaximum length of AI indications of 8% of weld: 230.0630 mm

RADIOGRAPHIC INFOPipe O.D. in inches: 36.00"Amount of Penetrameters required for each shot: 1 penetrameter 1" from the end of film and 1 penny in the center.Total weld length: 113.22" 2875.7880 mmCassette size to complete weld in most efficient way: 3.5 x 17" 4.5 x 17"Amount of shots to complete weld with 1" on each side of readable film: 68% of weld: 9.0576" 230.0630 mmHole penetrameters are adjacent to the weld and Wire penetrameters are parallel to the weld.

Page 2 of 2

Page 198: NDT Code Book Made Easy

PENETRAMETER SELECTIONNote: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Wire: 0.010 Esn. Wire: A1 or B6 S/S Hole: 15

F/S Wire: 0.008 Esn. Wire: A2 F/S Hole: 12Welds with reinforcement: S/S Wire: 0.013 Esn. Wire: B5 S/S Hole: 17

F/S Wire: 0.010 Esn. Wire: A1 or B6 F/S Hole: 15Maximum allowable reinforcement: 0.0625"/per sideMaximum reinforcement with DWE/SWV: 0.125" Total of walls + reinforcement: 0.875" 22.2250 mmMaximum reinforcement with DWE/DWV: 0.125" Total of walls + reinforcement: 0.875" 22.2250 mmMaximum reinforcement with SWE/SWV: 0.0625" Total of wall + reinforcement: 0.4375" 11.1125 mm

INADEQUATE PENETRATION WITHOUT HIGH LOWMaximum length of individual indication of IP : 1 inch or 25mmMaximum length of IP in 8% of weld: N/A since total weld exceeds 12 inchesMaximum length of indications in any continuous 12" length of weld: 1" 25 mm

INADEQUATE PENETRATION DUE TO HIGH LOWMaximum length of individual indication of IPD: 2 inches or 50mmMaximum length of indications of IPD in any continuous 12" length of weld: 3" 75 mm

INADEQUATE CROSS PENETRATIONMaximum length of an individual indication of ICP: 2 inches or 50mmMaximum length of indications of ICP in any continuous 12" length of weld: 2" 50 mm

INCOMPLETE FUSIONMaximum length of an individual indication of IF: 1 inch or 25mmMaximum length of IF in 8% of weld: N/A since total weld exceeds 12 inchesMaximum length of indications of IF in any continuous 12" length of weld: 1" 25 mm

INCOMPLETE FUSION DUE TO COLD LAPMaximum length of individual indications of IFD: 2 inches or 50mmMaximum length of IFD in 8% of weld: 230.0630 mmMaximum length of indications of IFD in any continuous 12" length of weld: 2" 25 mm

INTERNAL CONCAVITY Any length of IC is acceptable, provided the density of the radiographic image of the internal concavity does not exceed that of the thinnest adjacent parent material. For areas that exceed the density of thethinnest adjacent parent material, the criteria for burn through are applicable.

BURN - THROUGHMaximum dimension of BT's image : unacceptable if it exceeds that of the thinnest adjacent parent metal.Maximum dimension of BT: 1/4" or 6mmMaximum dimension is unacceptable if: it exceeds the thinner of the nonnal wall thickness joined, and the density

of the BT's image exceeds that of the thinnest adjacent parent material.The sum of the max dimensions of separate BBT's whose image density exceeds that of the thinnest adjacent parentmaterial exceeds 1/2 inch or 13mm in any continuous 12" length of weld or the total weld length(whichever is less).

API - 110436" Standard - 0.375" Wall

Page 1 of 2

Page 199: NDT Code Book Made Easy

API - 110436" Standard - 0.375" Wall

SLAG INCLUSIONSElongated slag inclusions (ESI)Maximum length of an ESI: 2 inches or 50mmParallel ESI indications (Wagon Tracks) shall be considered a single indication unless the width of either of them exceed1/32" or 0.8mm. In that event they shall be considered separate indications.Maximum length of ESI indications in any continuous 12" length of weld: 2" 50 mmMaximum width of an individual ESI indication: 1/16" or 1.6mmIsolated slag inclusions (ISI)Maximum length of ISI indications in any continuous 12" length of weld: 1/2" 13 mmMaximum width of an ISI indication: 1/8" or 3mmMaximum length of ESI and ISI in 8% of weld: 230.0630 mm

POROSITY Individual or Scattered Porosity.Maximum size of an individual pore: 1/8" or 3mmThe size of an individual pore exceeds 25% of the thinner of the nonimal wall thickness joined.The distribution of scattered porosity exceeds the concentration permitted in Figures 19 or 20.Cluster Porosity (CP)Maximum diameter of the cluster: 1/2 inch or 13mmMaximum length of CP indications in any continuous 12" length of weweld: 1/2" 13 mmMaximum length of an individual pore within a cluster: 1/16 inch or 2mmHollow Bead Porosity (HB)Maximum length of an individual indication of HB: 1/2 inch or 13mmMaximum length of HB indications in any continuous 12" length of weld: 2" 50 mmMaximum length of HB in 8% of weld: 230.0630 mmNOTE: The weld is unacceptable if individual indications of HB, each greater than 1/4 inch or 6mm in length, are seperated by less than 2 inches or 50 mm.

CRACKSNote: Any crack which is not a shallow crater crack or star crack is unacceptable.Maximum length of shallow crater cracks or star cracks: 5/32 inch or 4mm

UNDERCUTTINGUndercutting adjacent to the cover pass (EU) and Undercutting adjacent to the root pass (IU)Maximum length of EU and IU indications (in any combination) in a 12 inch length of weld: 2" 50 mmMaximum length of EU and IU indications: 18.87" 479.2980 mm (This value is 1/6 th of the total weld length)

ACCUMULATION OF IMPERFECTIONSMaximum length of AI indications in any continuous 12 inch or 300 mm length of weld: 2" 50 mmMaximum length of AI indications of 8% of weld: 230.0630 mm

RADIOGRAPHIC INFOPipe O.D. in inches: 36.00"Amount of Penetrameters required for each shot: 1 penetrameter 1" from the end of film and 1 penny in the center.Total weld length: 113.22" 2875.7880 mmCassette size to complete weld in most efficient way: 3.5 x 17" 4.5 x 17"Amount of shots to complete weld with 1" on each side of readable film: 68% of weld: 9.0576" 230.0630 mmHole penetrameters are adjacent to the weld and Wire penetrameters are parallel to the weld.

Page 2 of 2

Page 200: NDT Code Book Made Easy

PENETRAMETER SELECTIONNote: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Wire: 0.016 Esn. Wire: B4 S/S Hole: 20

F/S Wire: 0.013 Esn. Wire: B5 F/S Hole: 17Welds with reinforcement: S/S Wire: 0.020 Esn. Wire: B3 S/S Hole: 25

F/S Wire: 0.016 Esn. Wire: B4 F/S Hole: 20Maximum allowable reinforcement: 0.0625"/per sideMaximum reinforcement with DWE/SWV: 0.125" Total of walls + reinforcement: 1.625" 41.2750 mmMaximum reinforcement with DWE/DWV: 0.125" Total of walls + reinforcement: 1.625" 41.2750 mmMaximum reinforcement with SWE/SWV: 0.0625" Total of wall + reinforcement: 0.8125" 20.6375 mm

INADEQUATE PENETRATION WITHOUT HIGH LOWMaximum length of individual indication of IP : 1 inch or 25mmMaximum length of IP in 8% of weld: N/A since total weld exceeds 12 inchesMaximum length of indications in any continuous 12" length of weld: 1" 25 mm

INADEQUATE PENETRATION DUE TO HIGH LOWMaximum length of individual indication of IPD: 2 inches or 50mmMaximum length of indications of IPD in any continuous 12" length of weld: 3" 75 mm

INADEQUATE CROSS PENETRATIONMaximum length of an individual indication of ICP: 2 inches or 50mmMaximum length of indications of ICP in any continuous 12" length of weld: 2" 50 mm

INCOMPLETE FUSIONMaximum length of an individual indication of IF: 1 inch or 25mmMaximum length of IF in 8% of weld: N/A since total weld exceeds 12 inchesMaximum length of indications of IF in any continuous 12" length of weld: 1" 25 mm

INCOMPLETE FUSION DUE TO COLD LAPMaximum length of individual indications of IFD: 2 inches or 50mmMaximum length of IFD in 8% of weld: 230.0630 mmMaximum length of indications of IFD in any continuous 12" length of weld: 2" 25 mm

INTERNAL CONCAVITY Any length of IC is acceptable, provided the density of the radiographic image of the internal concavity does not exceed that of the thinnest adjacent parent material. For areas that exceed the density of thethinnest adjacent parent material, the criteria for burn through are applicable.

BURN - THROUGHMaximum dimension of BT's image : unacceptable if it exceeds that of the thinnest adjacent parent metal.Maximum dimension of BT: 1/4" or 6mmMaximum dimension is unacceptable if: it exceeds the thinner of the nonnal wall thickness joined, and the density

of the BT's image exceeds that of the thinnest adjacent parent material.The sum of the max dimensions of separate BBT's whose image density exceeds that of the thinnest adjacent parentmaterial exceeds 1/2 inch or 13mm in any continuous 12" length of weld or the total weld length(whichever is less).

API - 110436" s/40 - 0.750" Wall

Page 1 of 2

Page 201: NDT Code Book Made Easy

API - 110436" s/40 - 0.750" Wall

SLAG INCLUSIONSElongated slag inclusions (ESI)Maximum length of an ESI: 2 inches or 50mmParallel ESI indications (Wagon Tracks) shall be considered a single indication unless the width of either of them exceed1/32" or 0.8mm. In that event they shall be considered separate indications.Maximum length of ESI indications in any continuous 12" length of weld: 2" 50 mmMaximum width of an individual ESI indication: 1/16" or 1.6mmIsolated slag inclusions (ISI)Maximum length of ISI indications in any continuous 12" length of weld: 1/2" 13 mmMaximum width of an ISI indication: 1/8" or 3mmMaximum length of ESI and ISI in 8% of weld: 230.0630 mm

POROSITY Individual or Scattered Porosity.Maximum size of an individual pore: 1/8" or 3mmThe size of an individual pore exceeds 25% of the thinner of the nonimal wall thickness joined.The distribution of scattered porosity exceeds the concentration permitted in Figures 19 or 20.Cluster Porosity (CP)Maximum diameter of the cluster: 1/2 inch or 13mmMaximum length of CP indications in any continuous 12" length of weweld: 1/2" 13 mmMaximum length of an individual pore within a cluster: 1/16 inch or 2mmHollow Bead Porosity (HB)Maximum length of an individual indication of HB: 1/2 inch or 13mmMaximum length of HB indications in any continuous 12" length of weld: 2" 50 mmMaximum length of HB in 8% of weld: 230.0630 mmNOTE: The weld is unacceptable if individual indications of HB, each greater than 1/4 inch or 6mm in length, are seperated by less than 2 inches or 50 mm.

CRACKSNote: Any crack which is not a shallow crater crack or star crack is unacceptable.Maximum length of shallow crater cracks or star cracks: 5/32 inch or 4mm

UNDERCUTTINGUndercutting adjacent to the cover pass (EU) and Undercutting adjacent to the root pass (IU)Maximum length of EU and IU indications (in any combination) in a 12 inch length of weld: 2" 50 mmMaximum length of EU and IU indications: 18.87" 479.2980 mm (This value is 1/6 th of the total weld length)

ACCUMULATION OF IMPERFECTIONSMaximum length of AI indications in any continuous 12 inch or 300 mm length of weld: 2" 50 mmMaximum length of AI indications of 8% of weld: 230.0630 mm

RADIOGRAPHIC INFOPipe O.D. in inches: 36.00"Amount of Penetrameters required for each shot: 1 penetrameter 1" from the end of film and 1 penny in the center.Total weld length: 113.22" 2875.7880 mmCassette size to complete weld in most efficient way: 3.5 x 17" 4.5 x 17"Amount of shots to complete weld with 1" on each side of readable film: 68% of weld: 9.0576" 230.0630 mmHole penetrameters are adjacent to the weld and Wire penetrameters are parallel to the weld.

Page 2 of 2

Page 202: NDT Code Book Made Easy

PENETRAMETER SELECTIONNote: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Wire: 0.013 Esn. Wire: B5 S/S Hole: 17

F/S Wire: 0.010 Esn. Wire: A1 or B6 F/S Hole: 15Welds with reinforcement: S/S Wire: 0.016 Esn. Wire: B4 S/S Hole: 20

F/S Wire: 0.013 Esn. Wire: B5 F/S Hole: 17Maximum allowable reinforcement: 0.0625"/per sideMaximum reinforcement with DWE/SWV: 0.125" Total of walls + reinforcement: 1.125" 28.5750 mmMaximum reinforcement with DWE/DWV: 0.125" Total of walls + reinforcement: 1.125" 28.5750 mmMaximum reinforcement with SWE/SWV: 0.0625" Total of wall + reinforcement: 0.5625" 14.2875 mm

INADEQUATE PENETRATION WITHOUT HIGH LOWMaximum length of individual indication of IP : 1 inch or 25mmMaximum length of IP in 8% of weld: N/A since total weld exceeds 12 inchesMaximum length of indications in any continuous 12" length of weld: 1" 25 mm

INADEQUATE PENETRATION DUE TO HIGH LOWMaximum length of individual indication of IPD: 2 inches or 50mmMaximum length of indications of IPD in any continuous 12" length of weld: 3" 75 mm

INADEQUATE CROSS PENETRATIONMaximum length of an individual indication of ICP: 2 inches or 50mmMaximum length of indications of ICP in any continuous 12" length of weld: 2" 50 mm

INCOMPLETE FUSIONMaximum length of an individual indication of IF: 1 inch or 25mmMaximum length of IF in 8% of weld: N/A since total weld exceeds 12 inchesMaximum length of indications of IF in any continuous 12" length of weld: 1" 25 mm

INCOMPLETE FUSION DUE TO COLD LAPMaximum length of individual indications of IFD: 2 inches or 50mmMaximum length of IFD in 8% of weld: 230.0630 mmMaximum length of indications of IFD in any continuous 12" length of weld: 2" 25 mm

INTERNAL CONCAVITY Any length of IC is acceptable, provided the density of the radiographic image of the internal concavity does not exceed that of the thinnest adjacent parent material. For areas that exceed the density of thethinnest adjacent parent material, the criteria for burn through are applicable.

BURN - THROUGHMaximum dimension of BT's image : unacceptable if it exceeds that of the thinnest adjacent parent metal.Maximum dimension of BT: 1/4" or 6mmMaximum dimension is unacceptable if: it exceeds the thinner of the nonnal wall thickness joined, and the density

of the BT's image exceeds that of the thinnest adjacent parent material.The sum of the max dimensions of separate BBT's whose image density exceeds that of the thinnest adjacent parentmaterial exceeds 1/2 inch or 13mm in any continuous 12" length of weld or the total weld length(whichever is less).

API - 110436" Extra Strong - 0.500" Wall

Page 1 of 2

Page 203: NDT Code Book Made Easy

API - 110436" Extra Strong - 0.500" Wall

SLAG INCLUSIONSElongated slag inclusions (ESI)Maximum length of an ESI: 2 inches or 50mmParallel ESI indications (Wagon Tracks) shall be considered a single indication unless the width of either of them exceed1/32" or 0.8mm. In that event they shall be considered separate indications.Maximum length of ESI indications in any continuous 12" length of weld: 2" 50 mmMaximum width of an individual ESI indication: 1/16" or 1.6mmIsolated slag inclusions (ISI)Maximum length of ISI indications in any continuous 12" length of weld: 1/2" 13 mmMaximum width of an ISI indication: 1/8" or 3mmMaximum length of ESI and ISI in 8% of weld: 230.0630 mm

POROSITY Individual or Scattered Porosity.Maximum size of an individual pore: 1/8" or 3mmThe size of an individual pore exceeds 25% of the thinner of the nonimal wall thickness joined.The distribution of scattered porosity exceeds the concentration permitted in Figures 19 or 20.Cluster Porosity (CP)Maximum diameter of the cluster: 1/2 inch or 13mmMaximum length of CP indications in any continuous 12" length of weweld: 1/2" 13 mmMaximum length of an individual pore within a cluster: 1/16 inch or 2mmHollow Bead Porosity (HB)Maximum length of an individual indication of HB: 1/2 inch or 13mmMaximum length of HB indications in any continuous 12" length of weld: 2" 50 mmMaximum length of HB in 8% of weld: 230.0630 mmNOTE: The weld is unacceptable if individual indications of HB, each greater than 1/4 inch or 6mm in length, are seperated by less than 2 inches or 50 mm.

CRACKSNote: Any crack which is not a shallow crater crack or star crack is unacceptable.Maximum length of shallow crater cracks or star cracks: 5/32 inch or 4mm

UNDERCUTTINGUndercutting adjacent to the cover pass (EU) and Undercutting adjacent to the root pass (IU)Maximum length of EU and IU indications (in any combination) in a 12 inch length of weld: 2" 50 mmMaximum length of EU and IU indications: 18.87" 479.2980 mm (This value is 1/6 th of the total weld length)

ACCUMULATION OF IMPERFECTIONSMaximum length of AI indications in any continuous 12 inch or 300 mm length of weld: 2" 50 mmMaximum length of AI indications of 8% of weld: 230.0630 mm

RADIOGRAPHIC INFOPipe O.D. in inches: 36.00"Amount of Penetrameters required for each shot: 1 penetrameter 1" from the end of film and 1 penny in the center.Total weld length: 113.22" 2875.7880 mmCassette size to complete weld in most efficient way: 3.5 x 17" 4.5 x 17"Amount of shots to complete weld with 1" on each side of readable film: 68% of weld: 9.0576" 230.0630 mmHole penetrameters are adjacent to the weld and Wire penetrameters are parallel to the weld.

Page 2 of 2

Page 204: NDT Code Book Made Easy

s

B31.31/2" s/40 & Std. - 0.109" Wall

PENETRAMETER SELECTIONNote: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Hole: 12 S/S Wire: 0.008 Esn. Wire: A2

F/S Hole: 10 F/S Wire: 0.006 Esn. Wire: A3Welds with reinforcement: S/S Hole: 12 S/S Wire: 0.008 Esn. Wire: A2

F/S Hole: 10 F/S Wire: 0.006 Esn. Wire: A3Maximum allowable reinforcement: 0.0625" Total of wall + reinforcement: 0.172"CRACKS AND LACK OF FUSIONNone Allowed

INCOMPLETE PENETRATIONNormal ServiceGirth and Miter Groove, Branch Connections: Max 1.5" in a 6" length of weld.Longitudinal Groove: None allowed

Severe CyclicGirth and Miter Groove, Branch Connections, and Longitudinal Groove: None allowed

SLAG INCLUSION, TUNGSTEN INCLUSION, OR ELONGATED INDICATIONNormal ServiceMax Individual Length: 0.218 Max Individual Width: 0.055" Max Cumulative Length: 0.436 in 6" of weld

Severe Cyclic ConditionsMax Individual Length: 0.036" Max Individual Width: 0.036" Max Cumulative Length: 0.109" in 1.308" of w.

UNDERCUTTINGNormal Services: Not a factor for normal service

Severe Cyclic: Zero allowed

CONCAVE ROOT SURFACE (SUCK-UP)Normal Service and Severe Cyclic: Unacceptable if concave root is darker than the wall

INTERNAL POROSITYRelevant Indication: 0.012

Normal Services:Max Size of Random Internal Porosity: 0.027" Max Size of Isolated Internal Porosity: 0.036"Max Sum of diameters of Aligned Porosity: 0.109" in a 1.308" length of weldMax group length of Aligned Internal Porosity: 0.250"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 0.218"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.0"Max number of relevant internal porosity in a 6" length of of weld = 12

Severe Cyclic:Max size of Random Internal Porosity: 0.027" Max Size of Isolated Internal Porosity: 0.036"Max sum of diameters of Aligned Porosity: 0.109" in a 1.308" length of weld.Max group length of Aligned Internal Porosity: 0.250"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 0.218Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.0"Max number of relevant internal porosity in a 6" length of weld = 12

Page 205: NDT Code Book Made Easy

s

B31.31/2 s/80 & Extra Strong - 0.147" Wall

PENETRAMETER SELECTIONNote: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Hole: 12 S/S Wire: 0.008 Esn. Wire: A2

F/S Hole: 10 F/S Wire: 0.006 Esn. Wire: A3Welds with reinforcement: S/S Hole: 12 S/S Wire: 0.008 Esn. Wire: A2

F/S Hole: 10 F/S Wire: 0.006 Esn. Wire: A3Maximum allowable reinforcement: 0.0625" Total of wall + reinforcement: 0.210"CRACKS AND LACK OF FUSIONNone Allowed

INCOMPLETE PENETRATIONNormal ServiceGirth and Miter Groove, Branch Connections: Max 1.5" in a 6" length of weld.Longitudinal Groove: None allowed

Severe CyclicGirth and Miter Groove, Branch Connections, and Longitudinal Groove: None allowed

SLAG INCLUSION, TUNGSTEN INCLUSION, OR ELONGATED INDICATIONNormal ServiceMax Individual Length: 0.294" Max Individual Width: 0.074" Max Cumulative Length: 0.588" in 6" of weld

Severe Cyclic ConditionsMax Individual Length: 0.049" Max Individual Width: 0.049" Max Cumulative Length: 0.147" in 1.764" of w.

UNDERCUTTINGNormal Services: Not a factor for normal service

Severe Cyclic: Zero allowed

CONCAVE ROOT SURFACE (SUCK-UP)Normal Service and Severe Cyclic: Unacceptable if concave root is darker than the wall

INTERNAL POROSITYRelevant Indication: 0.016

Normal Services:Max Size of Random Internal Porosity: 0.037" Max Size of Isolated Internal Porosity: 0.049"Max Sum of diameters of Aligned Porosity: 0.147" in a 1.764" length of weldMax group length of Aligned Internal Porosity: 0.250"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 0.294"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.0"

Severe Cyclic:Max size of Random Internal Porosity: 0.037" Max Size of Isolated Internal Porosity: 0.049"Max sum of diameters of Aligned Porosity: 0.147" in a 1.764" length of weldMax group length of Aligned Internal Porosity: 0.250"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 0.294"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.0"

Page 206: NDT Code Book Made Easy

s

B31.31/2" s/160 - 0.188" Wall

PENETRAMETER SELECTIONNote: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Hole: 12 S/S Wire: 0.008 Esn. Wire: A2

F/S Hole: 10 F/S Wire: 0.006 Esn. Wire: A3Welds with reinforcement: S/S Hole: 15 S/S Wire: 0.010 Esn. Wire: A1 or B6

F/S Hole: 12 F/S Wire: 0.008 Esn. Wire: A2Maximum allowable reinforcement: 0.0625" Total of wall + reinforcement: 0.251"CRACKS AND LACK OF FUSIONNone Allowed

INCOMPLETE PENETRATIONNormal ServiceGirth and Miter Groove, Branch Connections: Max 1.5" in a 6" length of weld.Longitudinal Groove: None allowed

Severe CyclicGirth and Miter Groove, Branch Connections, and Longitudinal Groove: None allowed

SLAG INCLUSION, TUNGSTEN INCLUSION, OR ELONGATED INDICATIONNormal ServiceMax Individual Length: 0.376" Max Individual Width: 0.094" Max Cumulative Length: 0.752" in 6" of weld

Severe Cyclic ConditionsMax Individual Length: 0.063" Max Individual Width: 0.063" Max Cumulative Length: 0.188" in 2.256" of w.

UNDERCUTTINGNormal Services: Not a factor for normal service

Severe Cyclic: Zero allowed

CONCAVE ROOT SURFACE (SUCK-UP)Normal Service and Severe Cyclic: Unacceptable if concave root is darker than the wall

INTERNAL POROSITYRelevant Indication: 0.016

Normal Services:Max Size of Random Internal Porosity: 0.047" Max Size of Isolated Internal Porosity: 0.063"Max Sum of diameters of Aligned Porosity: 0.188" in a 2.256" length of weldMax group length of Aligned Internal Porosity: 0.250"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 0.376"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.0"

Severe Cyclic:Max size of Random Internal Porosity: 0.047" Max Size of Isolated Internal Porosity: 0.063"Max sum of diameters of Aligned Porosity: 0.188" in a 2.256" length of weld.Max group length of Aligned Internal Porosity: 0.250"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 0.376"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.0"

Page 207: NDT Code Book Made Easy

s

B31.33/4" s/40 & Std. - 0.113" Wall

PENETRAMETER SELECTIONNote: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Hole: 12 S/S Wire: 0.008 Esn. Wire: A2

F/S Hole: 10 F/S Wire: 0.006 Esn. Wire: A3Welds with reinforcement: S/S Hole: 12 S/S Wire: 0.008 Esn. Wire: A2

F/S Hole: 10 F/S Wire: 0.006 Esn. Wire: A3Maximum allowable reinforcement: 0.0625" Total of wall + reinforcement: 0.176"CRACKS AND LACK OF FUSIONNone Allowed

INCOMPLETE PENETRATIONNormal ServiceGirth and Miter Groove, Branch Connections: Max 1.5" in a 6" length of weld.Longitudinal Groove: None allowed

Severe CyclicGirth and Miter Groove, Branch Connections, and Longitudinal Groove: None allowed

SLAG INCLUSION, TUNGSTEN INCLUSION, OR ELONGATED INDICATIONNormal ServiceMax Individual Length: 0.226" Max Individual Width: 0.057" Max Cumulative Length: 0.452" in 6" of weld

Severe Cyclic ConditionsMax Individual Length: 0.038" Max Individual Width: 0.038" Max Cumulative Length: 0.113" in 1.356" of w.

UNDERCUTTINGNormal Services: Not a factor for normal service

Severe Cyclic: Zero allowed

CONCAVE ROOT SURFACE (SUCK-UP)Normal Service and Severe Cyclic: Unacceptable if concave root is darker than the wall

INTERNAL POROSITYRelevant Indication: 0.012

Normal Services:Max Size of Random Internal Porosity: 0.028" Max Size of Isolated Internal Porosity: 0.038"Max Sum of diameters of Aligned Porosity: 0.113" in a 1.356" length of weldMax group length of Aligned Internal Porosity: 0.250"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 0.226"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.0"Max number of relevant internal porosity in a 6" length of of weld = 12

Severe Cyclic:Max size of Random Internal Porosity: 0.028" Max Size of Isolated Internal Porosity: 0.038"Max sum of diameters of Aligned Porosity: 0.113" in a 1.356" length of weldMax group length of Aligned Internal Porosity: 0.250"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 0.226"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.0"Max number of relevant internal porosity in a 6" length of weld = 12

Page 208: NDT Code Book Made Easy

s

B31.33/4" s/80 & Extra Strong - 0.154" Wall

PENETRAMETER SELECTIONNote: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Hole: 12 S/S Wire: 0.008 Esn. Wire: A2

F/S Hole: 10 F/S Wire: 0.006 Esn. Wire: A3Welds with reinforcement: S/S Hole: 12 S/S Wire: 0.008 Esn. Wire: A2

F/S Hole: 10 F/S Wire: 0.006 Esn. Wire: A3Maximum allowable reinforcement: 0.0625" Total of wall + reinforcement: 0.217"CRACKS AND LACK OF FUSIONNone Allowed

INCOMPLETE PENETRATIONNormal ServiceGirth and Miter Groove, Branch Connections: Max 1.5" in a 6" length of weld.Longitudinal Groove: None allowed

Severe CyclicGirth and Miter Groove, Branch Connections, and Longitudinal Groove: None allowed

SLAG INCLUSION, TUNGSTEN INCLUSION, OR ELONGATED INDICATIONNormal ServiceMax Individual Length: 0.308" Max Individual Width: 0.077" Max Cumulative Length: 0.616" in 6" of weld

Severe Cyclic ConditionsMax Individual Length: 0.051" Max Individual Width: 0.051" Max Cumulative Length: 0.154" in 1.848" of w.

UNDERCUTTINGNormal Services: Not a factor for normal service

Severe Cyclic: Zero allowed

CONCAVE ROOT SURFACE (SUCK-UP)Normal Service and Severe Cyclic: Unacceptable if concave root is darker than the wall

INTERNAL POROSITYRelevant Indication: 0.016

Normal Services:Max Size of Random Internal Porosity: 0.039" Max Size of Isolated Internal Porosity: 0.051"Max Sum of diameters of Aligned Porosity: 0.154" in a 1.848" length of weldMax group length of Aligned Internal Porosity: 0.250"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 0.308"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.0"

Severe Cyclic:Max size of Random Internal Porosity: 0.039" Max Size of Isolated Internal Porosity: 0.051"Max sum of diameters of Aligned Porosity: 0.154" in a 1.848" length of weldMax group length of Aligned Internal Porosity: 0.250"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 0.308"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.0"

Page 209: NDT Code Book Made Easy

s

B31.33/4" s/160 - 0.219" Wall

PENETRAMETER SELECTIONNote: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Hole: 12 S/S Wire: 0.008 Esn. Wire: A2

F/S Hole: 10 F/S Wire: 0.006 Esn. Wire: A3Welds with reinforcement: S/S Hole: 15 S/S Wire: 0.010 Esn. Wire: A1 or B6

F/S Hole: 12 F/S Wire: 0.008 Esn. Wire: A2Maximum allowable reinforcement: 0.0625" Total of wall + reinforcement: 0.282"CRACKS AND LACK OF FUSIONNone Allowed

INCOMPLETE PENETRATIONNormal ServiceGirth and Miter Groove, Branch Connections: Max 1.5" in a 6" length of weld.Longitudinal Groove: None allowed

Severe CyclicGirth and Miter Groove, Branch Connections, and Longitudinal Groove: None allowed

SLAG INCLUSION, TUNGSTEN INCLUSION, OR ELONGATED INDICATIONNormal ServiceMax Individual Length: 0.438" Max Individual Width: 0.110" Max Cumulative Length: 0.876" in 6" of weld

Severe Cyclic ConditionsMax Individual Length: 0.073" Max Individual Width: 0.073" Max Cumulative Length: 0.219" in 2.628" of w

UNDERCUTTINGNormal Services: Not a factor for normal service

Severe Cyclic: Zero allowed

CONCAVE ROOT SURFACE (SUCK-UP)Normal Service and Severe Cyclic: Unacceptable if concave root is darker than the wall

INTERNAL POROSITYRelevant Indication: 0.016

Normal Services:Max Size of Random Internal Porosity: 0.055" Max Size of Isolated Internal Porosity: 0.073"Max Sum of diameters of Aligned Porosity: 0.219" in a 2.628" length of weldMax group length of Aligned Internal Porosity: 0.250"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 0.438"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.0"

Severe Cyclic:Max size of Random Internal Porosity: 0.055" Max Size of Isolated Internal Porosity: 0.073"Max sum of diameters of Aligned Porosity: 0.219" in a 2.628" length of weldMax group length of Aligned Internal Porosity: 0.250"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 0.438"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.0"

Page 210: NDT Code Book Made Easy

s

B31.33/4" XX Strong - 0.308" Wall

PENETRAMETER SELECTIONNote: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Hole: 15 S/S Wire: 0.010 Esn. Wire: A1 or B6

F/S Hole: 12 F/S Wire: 0.008 Esn. Wire: A2Welds with reinforcement: S/S Hole: 17 S/S Wire: 0.013 Esn. Wire: B5

F/S Hole: 15 F/S Wire: 0.010 Esn. Wire: A1 or B6Maximum allowable reinforcement: 0.125" Total of wall + reinforcement: 0.433"CRACKS AND LACK OF FUSIONNone Allowed

INCOMPLETE PENETRATIONNormal ServiceGirth and Miter Groove, Branch Connections: Max 1.5" in a 6" length of weld.Longitudinal Groove: None allowed

Severe CyclicGirth and Miter Groove, Branch Connections, and Longitudinal Groove: None allowed

SLAG INCLUSION, TUNGSTEN INCLUSION, OR ELONGATED INDICATIONNormal ServiceMax Individual Length: 0.616" Max Individual Width: 0.125" Max Cumulative Length: 1.232" in 6" of weld

Severe Cyclic ConditionsMax Individual Length: 0.103" Max Individual Width: 0.094" Max Cumulative Length: 0.308" in 3.696" of w

UNDERCUTTINGNormal Services: Not a factor for normal service

Severe Cyclic: Zero allowed

CONCAVE ROOT SURFACE (SUCK-UP)Normal Service and Severe Cyclic: Unacceptable if concave root is darker than the wall

INTERNAL POROSITYRelevant Indication: 0.031"

Normal Services:Max Size of Random Internal Porosity: 0.116" Max Size of Isolated Internal Porosity: 0.154"Max Sum of diameters of Aligned Porosity: 0.462" in a 3.696" length of weldMax group length of Aligned Internal Porosity: 0.375"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 0.924"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.5"

Severe Cyclic:Max size of Random Internal Porosity: 0.077" Max Size of Isolated Internal Porosity: 0.103"Max sum of diameters of Aligned Porosity: 0.308" in a 3.696" length of weldMax group length of Aligned Internal Porosity: 0.250"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 0.616"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.0"

Page 211: NDT Code Book Made Easy

s

B31.31" s/10 - 0.109" Wall

PENETRAMETER SELECTIONNote: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Hole: 12 S/S Wire: 0.008 Esn. Wire: A2

F/S Hole: 10 F/S Wire: 0.006 Esn. Wire: A3Welds with reinforcement: S/S Hole: 12 S/S Wire: 0.008 Esn. Wire: A2

F/S Hole: 10 F/S Wire: 0.006 Esn. Wire: A3Maximum allowable reinforcement: 0.0625" Total of wall + reinforcement: 0.172"CRACKS AND LACK OF FUSIONNone Allowed

INCOMPLETE PENETRATIONNormal ServiceGirth and Miter Groove, Branch Connections: Max 1.5" in a 6" length of weld.Longitudinal Groove: None allowed

Severe CyclicGirth and Miter Groove, Branch Connections, and Longitudinal Groove: None allowed

SLAG INCLUSION, TUNGSTEN INCLUSION, OR ELONGATED INDICATIONNormal ServiceMax Individual Length: 0.218" Max Individual Width: 0.055" Max Cumulative Length: 0.436" in 6" of weld

Severe Cyclic ConditionsMax Individual Length: 0.036" Max Individual Width: 0.036" Max Cumulative Length: 0.109" in 1.308" of w

UNDERCUTTINGNormal Services: Not a factor for normal service

Severe Cyclic: Zero allowed

CONCAVE ROOT SURFACE (SUCK-UP)Normal Service and Severe Cyclic: Unacceptable if concave root is darker than the wall

INTERNAL POROSITYRelevant Indication: 0.012

Normal Services:Max Size of Random Internal Porosity: 0.027" Max Size of Isolated Internal Porosity: 0.036"Max Sum of diameters of Aligned Porosity: 0.109" in a 1.308" length of weldMax group length of Aligned Internal Porosity: 0.250"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 0.218"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.0"Max number of relevant internal porosity in a 6" length of weld = 12

Severe Cyclic:Max size of Random Internal Porosity: 0.027" Max Size of Isolated Internal Porosity: 0.036"Max sum of diameters of Aligned Porosity: 0.109" in a 1.308" length of weldMax group length of Aligned Internal Porosity: 0.250"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 0.218"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.0"Max number of relevant internal porosity in a 6" length of weld = 12

Page 212: NDT Code Book Made Easy

s

B31.31" s/40 & Std. - 0.133" Wall

PENETRAMETER SELECTIONNote: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Hole: 12 S/S Wire: 0.008 Esn. Wire: A2

F/S Hole: 10 F/S Wire: 0.006 Esn. Wire: A3Welds with reinforcement: S/S Hole: 12 S/S Wire: 0.008 Esn. Wire: A2

F/S Hole: 10 F/S Wire: 0.006 Esn. Wire: A3Maximum allowable reinforcement: 0.0625" Total of wall + reinforcement: 0.196"CRACKS AND LACK OF FUSIONNone Allowed

INCOMPLETE PENETRATIONNormal ServiceGirth and Miter Groove, Branch Connections: Max 1.5" in a 6" length of weld.Longitudinal Groove: None allowed

Severe CyclicGirth and Miter Groove, Branch Connections, and Longitudinal Groove: None allowed

SLAG INCLUSION, TUNGSTEN INCLUSION, OR ELONGATED INDICATIONNormal ServiceMax Individual Length: 0.266" Max Individual Width: 0.067" Max Cumulative Length: 0.532" in 6" of weld

Severe Cyclic ConditionsMax Individual Length: 0.044" Max Individual Width: 0.044" Max Cumulative Length: 0.133" in 1.596" of w

UNDERCUTTINGNormal Services: Not a factor for normal service

Severe Cyclic: Zero allowed

CONCAVE ROOT SURFACE (SUCK-UP)Normal Service and Severe Cyclic: Unacceptable if concave root is darker than the wall

INTERNAL POROSITYRelevant Indication: 0.016

Normal Services:Max Size of Random Internal Porosity: 0.033" Max Size of Isolated Internal Porosity: 0.044"Max Sum of diameters of Aligned Porosity: 0.133" in a 1.596" length of weldMax group length of Aligned Internal Porosity: 0.250"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 0.266"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.0"

Severe Cyclic:Max size of Random Internal Porosity: 0.033" Max Size of Isolated Internal Porosity: 0.044"Max sum of diameters of Aligned Porosity: 0.133" in a 1.596" length of weldMax group length of Aligned Internal Porosity: 0.250"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 0.266"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.0"

Page 213: NDT Code Book Made Easy

s

B31.31" s/80 & Extra Strong - 0.179" Wall

PENETRAMETER SELECTIONNote: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: ` 12 S/S Wire: 0.008 Esn. Wire: A2

F/S Hole: 10 F/S Wire: 0.006 Esn. Wire: A3Welds with reinforcement: S/S Hole: 12 S/S Wire: 0.008 Esn. Wire: A2

F/S Hole: 10 F/S Wire: 0.006 Esn. Wire: A3Maximum allowable reinforcement: 0.0625" Total of wall + reinforcement: 0.242"CRACKS AND LACK OF FUSIONNone Allowed

INCOMPLETE PENETRATIONNormal ServiceGirth and Miter Groove, Branch Connections: Max 1.5" in a 6" length of weld.Longitudinal Groove: None allowed

Severe CyclicGirth and Miter Groove, Branch Connections, and Longitudinal Groove: None allowed

SLAG INCLUSION, TUNGSTEN INCLUSION, OR ELONGATED INDICATIONNormal ServiceMax Individual Length: 0.358" Max Individual Width: 0.090" Max Cumulative Length: 0.716" in 6" of weld

Severe Cyclic ConditionsMax Individual Length: 0.060" Max Individual Width: 0.060" Max Cumulative Length: 0.179" in 2.148" of w

UNDERCUTTINGNormal Services: Not a factor for normal service

Severe Cyclic: Zero allowed

CONCAVE ROOT SURFACE (SUCK-UP)Normal Service and Severe Cyclic: Unacceptable if concave root is darker than the wall

INTERNAL POROSITYRelevant Indication: 0.016

Normal Services:Max Size of Random Internal Porosity: 0.045" Max Size of Isolated Internal Porosity: 0.060"Max Sum of diameters of Aligned Porosity: 0.179" in a 2.148" length of weldMax group length of Aligned Internal Porosity: 0.250"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 0.358"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.0"

Severe Cyclic:Max size of Random Internal Porosity: 0.045" Max Size of Isolated Internal Porosity: 0.060"Max sum of diameters of Aligned Porosity: 0.179" in a 2.148" length of weldMax group length of Aligned Internal Porosity: 0.250"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 0.358"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.0"

Page 214: NDT Code Book Made Easy

s

B31.31" s/160 - 0.250" Wall

PENETRAMETER SELECTIONNote: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Hole: 12 S/S Wire: 0.008 Esn. Wire: A2

F/S Hole: 10 F/S Wire: 0.006 Esn. Wire: A3Welds with reinforcement: S/S Hole: 15 S/S Wire: 0.010 Esn. Wire: A1 or B6

F/S Hole: 12 F/S Wire: 0.008 Esn. Wire: A2Maximum allowable reinforcement: 0.0625" Total of wall + reinforcement: 0.313"CRACKS AND LACK OF FUSIONNone Allowed

INCOMPLETE PENETRATIONNormal ServiceGirth and Miter Groove, Branch Connections: Max 1.5" in a 6" length of weld.Longitudinal Groove: None allowed

Severe CyclicGirth and Miter Groove, Branch Connections, and Longitudinal Groove: None allowed

SLAG INCLUSION, TUNGSTEN INCLUSION, OR ELONGATED INDICATIONNormal ServiceMax Individual Length: 0.500" Max Individual Width: 0.125" Max Cumulative Length: 1.000 in 6" of weld

Severe Cyclic ConditionsMax Individual Length: 0.083" Max Individual Width: 0.083" Max Cumulative Length: 0.250" in 3.000" of w

UNDERCUTTINGNormal Services: Not a factor for normal service

Severe Cyclic: Zero allowed

CONCAVE ROOT SURFACE (SUCK-UP)Normal Service and Severe Cyclic: Unacceptable if concave root is darker than the wall

INTERNAL POROSITYRelevant Indication: 0.016

Normal Services:Max Size of Random Internal Porosity: 0.063" Max Size of Isolated Internal Porosity: 0.083"Max Sum of diameters of Aligned Porosity: 0.250" in a 3.000" length of weldMax group length of Aligned Internal Porosity: 0.250"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 0.500"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.0"

Severe Cyclic:Max size of Random Internal Porosity: 0.063" Max Size of Isolated Internal Porosity: 0.083"Max sum of diameters of Aligned Porosity: 0.250" in 3.000" length of weldMax group length of Aligned Internal Porosity: 0.250"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 0.500"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.0"

Page 215: NDT Code Book Made Easy

s

B31.31" XX Strong - 0.358" Wall

PENETRAMETER SELECTIONNote: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Hole: 15 S/S Wire: 0.010 Esn. Wire: A1 or B6

F/S Hole: 12 F/S Wire: 0.008 Esn. Wire: A2Welds with reinforcement: S/S Hole: 17 S/S Wire: 0.013 Esn. Wire: B5

F/S Hole: 15 F/S Wire: 0.010 Esn. Wire: A1 or B6Maximum allowable reinforcement: 0.125" Total of wall + reinforcement: 0.483"CRACKS AND LACK OF FUSIONNone Allowed

INCOMPLETE PENETRATIONNormal ServiceGirth and Miter Groove, Branch Connections: Max 1.5" in a 6" length of weld.Longitudinal Groove: None allowed

Severe CyclicGirth and Miter Groove, Branch Connections, and Longitudinal Groove: None allowed

SLAG INCLUSION, TUNGSTEN INCLUSION, OR ELONGATED INDICATIONNormal ServiceMax Individual Length: 0.716" Max Individual Width: 0.125" Max Cumulative Length: 1.432" in 6" of weld

Severe Cyclic ConditionsMax Individual Length: 0.119" Max Individual Width: 0.094" Max Cumulative Length: 0.358" in 4.296" of w

UNDERCUTTINGNormal Services: Not a factor for normal service

Severe Cyclic: Zero allowed

CONCAVE ROOT SURFACE (SUCK-UP)Normal Service and Severe Cyclic: Unacceptable if concave root is darker than the wall

INTERNAL POROSITYRelevant Indication: 0.031

Normal Services:Max Size of Random Internal Porosity: 0.134" Max Size of Isolated Internal Porosity: 0.179"Max Sum of diameters of Aligned Porosity: 0.537" in a 4.296" length of weldMax group length of Aligned Internal Porosity: 0.375"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 1.074"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.5"

Severe Cyclic:Max size of Random Internal Porosity: 0.090" Max Size of Isolated Internal Porosity: 0.119"Max sum of diameters of Aligned Porosity: 0.358" in a 4.296" length of weldMax group length of Aligned Internal Porosity: 0.250"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 0.716"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.0"

Page 216: NDT Code Book Made Easy

s

B31.31.25" s/10 - 0.109" Wall

PENETRAMETER SELECTIONNote: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Hole: 12 S/S Wire: 0.008 Esn. Wire: A2

F/S Hole: 10 F/S Wire: 0.006 Esn. Wire: A3Welds with reinforcement: S/S Hole: 12 S/S Wire: 0.008 Esn. Wire: A2

F/S Hole: 10 F/S Wire: 0.006 Esn. Wire: A3Maximum allowable reinforcement: 0.625" Total of wall + reinforcement: 0.172"CRACKS AND LACK OF FUSIONNone Allowed

INCOMPLETE PENETRATIONNormal ServiceGirth and Miter Groove, Branch Connections: Max 1.5" in a 6" length of weld.Longitudinal Groove: None allowed

Severe CyclicGirth and Miter Groove, Branch Connections, and Longitudinal Groove: None allowed

SLAG INCLUSION, TUNGSTEN INCLUSION, OR ELONGATED INDICATIONNormal ServiceMax Individual Length: 0.218" Max Individual Width: 0.055" Max Cumulative Length: 0.436" in 6" of weld

Severe Cyclic ConditionsMax Individual Length: 0.036" Max Individual Width: 0.036" Max Cumulative Length: 0.109" in 1.308" of w

UNDERCUTTINGNormal Services: Not a factor for normal service

Severe Cyclic: Zero allowed

CONCAVE ROOT SURFACE (SUCK-UP)Normal Service and Severe Cyclic: Unacceptable if concave root is darker than the wall

INTERNAL POROSITYRelevant Indication: 0.012

Normal Services:Max Size of Random Internal Porosity: 0.027" Max Size of Isolated Internal Porosity: 0.036"Max Sum of diameters of Aligned Porosity: 0.109" in a 1.308" length of weldMax group length of Aligned Internal Porosity: 0.250"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 0.218"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.0"Max number of relevant internal porosity in a 6" length of weld = 12Severe Cyclic:Max size of Random Internal Porosity: 0.027" Max Size of Isolated Internal Porosity: 0.036"Max sum of diameters of Aligned Porosity: 0.109" in a 1.308" length of weldMax group length of Aligned Internal Porosity: 0.250"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 0.218"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.0"Max number of relevant internal porosity in a 6" length of weld = 12

Page 217: NDT Code Book Made Easy

s

B31.31.25" s/40 & Std. - 0.140" Wall

PENETRAMETER SELECTIONNote: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Hole: 12 S/S Wire: 0.008 Esn. Wire: A2

F/S Hole: 10 F/S Wire: 0.006 Esn. Wire: A3Welds with reinforcement: S/S Hole: 12 S/S Wire: 0.008 Esn. Wire: A2

F/S Hole: 10 F/S Wire: 0.006 Esn. Wire: A3Maximum allowable reinforcement: 0.625" Total of wall + reinforcement: 0.203"CRACKS AND LACK OF FUSIONNone Allowed

INCOMPLETE PENETRATIONNormal ServiceGirth and Miter Groove, Branch Connections: Max 1.5" in a 6" length of weld.Longitudinal Groove: None allowed

Severe CyclicGirth and Miter Groove, Branch Connections, and Longitudinal Groove: None allowed

SLAG INCLUSION, TUNGSTEN INCLUSION, OR ELONGATED INDICATIONNormal ServiceMax Individual Length: 0.280" Max Individual Width: 0.070" Max Cumulative Length: 0.560" in 6" of weld

Severe Cyclic ConditionsMax Individual Length: 0.047" Max Individual Width: 0.047" Max Cumulative Length: 0.140" in 1.680" of w

UNDERCUTTINGNormal Services: Not a factor for normal service

Severe Cyclic: Zero allowed

CONCAVE ROOT SURFACE (SUCK-UP)Normal Service and Severe Cyclic: Unacceptable if concave root is darker than the wall

INTERNAL POROSITYRelevant Indication: 0.016

Normal Services:Max Size of Random Internal Porosity: 0.035" Max Size of Isolated Internal Porosity: 0.047"Max Sum of diameters of Aligned Porosity: 0.140" in a 1.680" length of weldMax group length of Aligned Internal Porosity: 0.250"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 0.280"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.0"Severe Cyclic:Max size of Random Internal Porosity: 0.035" Max Size of Isolated Internal Porosity: 0.047"Max sum of diameters of Aligned Porosity: 0.140" in a 1.680" length of weldMax group length of Aligned Internal Porosity: 0.250"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 0.280"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.0"

Page 218: NDT Code Book Made Easy

s

B31.31.25" s/160 - 0.250" Wall

PENETRAMETER SELECTIONNote: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Hole: 12 S/S Wire: 0.008 Esn. Wire: A2

F/S Hole: 10 F/S Wire: 0.006 Esn. Wire: A3Welds with reinforcement: S/S Hole: 15 S/S Wire: 0.010 Esn. Wire: A1 or B6

F/S Hole: 12 F/S Wire: 0.008 Esn. Wire: A2Maximum allowable reinforcement: 0.625" Total of wall + reinforcement: 0.313"CRACKS AND LACK OF FUSIONNone Allowed

INCOMPLETE PENETRATIONNormal ServiceGirth and Miter Groove, Branch Connections: Max 1.5" in a 6" length of weld.Longitudinal Groove: None allowed

Severe CyclicGirth and Miter Groove, Branch Connections, and Longitudinal Groove: None allowed

SLAG INCLUSION, TUNGSTEN INCLUSION, OR ELONGATED INDICATIONNormal ServiceMax Individual Length: 0.500" Max Individual Width: 0.125" Max Cumulative Length: 1.000" in 6" of weld

Severe Cyclic ConditionsMax Individual Length: 0.083" Max Individual Width: 0.083" Max Cumulative Length: 0.250" in 3.000" of w

UNDERCUTTINGNormal Services: Not a factor for normal service

Severe Cyclic: Zero allowed

CONCAVE ROOT SURFACE (SUCK-UP)Normal Service and Severe Cyclic: Unacceptable if concave root is darker than the wall

INTERNAL POROSITYRelevant Indication: 0.016

Normal Services:Max Size of Random Internal Porosity: 0.063" Max Size of Isolated Internal Porosity: 0.083"Max Sum of diameters of Aligned Porosity: 0.250" in a 3.000" length of weldMax group length of Aligned Internal Porosity: 0.250"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 0.500"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.0"Severe Cyclic:Max size of Random Internal Porosity: 0.063" Max Size of Isolated Internal Porosity: 0.083"Max sum of diameters of Aligned Porosity: 0.250" in 3.000" length of weldMax group length of Aligned Internal Porosity: 0.250"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 0.500"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.0"

Page 219: NDT Code Book Made Easy

s

B31.31.25" XX Strong - 0.382" Wall

PENETRAMETER SELECTIONNote: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Hole: 17 S/S Wire: 0.013 Esn. Wire: B5

F/S Hole: 15 F/S Wire: 0.010 Esn. Wire: A1 or B6Welds with reinforcement: S/S Hole: 20 S/S Wire: 0.016 Esn. Wire: B4

F/S Hole: 17 F/S Wire: 0.013 Esn. Wire: B5Maximum allowable reinforcement: 0.125" Total of wall + reinforcement: 0.507"CRACKS AND LACK OF FUSIONNone Allowed

INCOMPLETE PENETRATIONNormal ServiceGirth and Miter Groove, Branch Connections: Max 1.5" in a 6" length of weld.Longitudinal Groove: None allowed

Severe CyclicGirth and Miter Groove, Branch Connections, and Longitudinal Groove: None allowed

SLAG INCLUSION, TUNGSTEN INCLUSION, OR ELONGATED INDICATIONNormal ServiceMax Individual Length: 0.764" Max Individual Width: 0.125" Max Cumulative Length: 1.528" in 6" of weld

Severe Cyclic ConditionsMax Individual Length: 0.127" Max Individual Width: 0.094" Max Cumulative Length: 0.382" in 4.584" of w

UNDERCUTTINGNormal Services: Not a factor for normal service

Severe Cyclic: Zero allowed

CONCAVE ROOT SURFACE (SUCK-UP)Normal Service and Severe Cyclic: Unacceptable if concave root is darker than the wall

INTERNAL POROSITYRelevant Indication: 0.031

Normal Services:Max Size of Random Internal Porosity: 0.143" Max Size of Isolated Internal Porosity: 0.191"Max Sum of diameters of Aligned Porosity: 0.573" in a 4.584" length of weldMax group length of Aligned Internal Porosity: 0.375"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 1.146"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.5"Severe Cyclic:Max size of Random Internal Porosity: 0.096" Max Size of Isolated Internal Porosity: 0.127"Max sum of diameters of Aligned Porosity: 0.382" in a 4.584" length of weldMax group length of Aligned Internal Porosity: 0.250"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 0.764"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.0"

Page 220: NDT Code Book Made Easy

s

B31.31.5" s/10 - 0.109" Wall

PENETRAMETER SELECTIONNote: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Hole: 12 S/S Wire: 0.008 Esn. Wire: A2

F/S Hole: 10 F/S Wire: 0.006 Esn. Wire: A3Welds with reinforcement: S/S Hole: 12 S/S Wire: 0.008 Esn. Wire: A2

F/S Hole: 10 F/S Wire: 0.006 Esn. Wire: A3Maximum allowable reinforcement: 0.0625" Total of wall + reinforcement: 0.172"CRACKS AND LACK OF FUSIONNone Allowed

INCOMPLETE PENETRATIONNormal ServiceGirth and Miter Groove, Branch Connections: Max 1.5" in a 6" length of weld.Longitudinal Groove: None allowed

Severe CyclicGirth and Miter Groove, Branch Connections, and Longitudinal Groove: None allowed

SLAG INCLUSION, TUNGSTEN INCLUSION, OR ELONGATED INDICATIONNormal ServiceMax Individual Length: 0.218" Max Individual Width: 0.055" Max Cumulative Length: 0.436" in 6" of weld

Severe Cyclic ConditionsMax Individual Length: 0.036" Max Individual Width: 0.036" Max Cumulative Length: 0.109" in 1.308" of w

UNDERCUTTINGNormal Services: Not a factor for normal service

Severe Cyclic: Zero allowed

CONCAVE ROOT SURFACE (SUCK-UP)Normal Service and Severe Cyclic: Unacceptable if concave root is darker than the wall

INTERNAL POROSITYRelevant Indication: 0.012

Normal Services:Max Size of Random Internal Porosity: 0.027" Max Size of Isolated Internal Porosity: 0.036"Max Sum of diameters of Aligned Porosity: 0.109" in a 1.308" length of weldMax group length of Aligned Internal Porosity: 0.250"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 0.218'Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.0"Max number of relevant internal porosity in a 6" length of of weld = 12

Severe Cyclic:Max size of Random Internal Porosity: 0.027" Max Size of Isolated Internal Porosity: 0.036"Max sum of diameters of Aligned Porosity: 0.109" in a 1.308" length of weldMax group length of Aligned Internal Porosity: 0.250"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 0.218"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.0"Max number of relevant internal porosity in a 6" length of weld = 12

Page 221: NDT Code Book Made Easy

s

B31.31.5" s/40 & /Std. - 0.145" Wall

PENETRAMETER SELECTIONNote: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Hole: 12 S/S Wire: 0.008 Esn. Wire: A2

F/S Hole: 10 F/S Wire: 0.006 Esn. Wire: A3Welds with reinforcement: S/S Hole: 12 S/S Wire: 0.008 Esn. Wire: A2

F/S Hole: 10 F/S Wire: 0.006 Esn. Wire: A3Maximum allowable reinforcement: 0.0625" Total of wall + reinforcement: 0.208"CRACKS AND LACK OF FUSIONNone Allowed

INCOMPLETE PENETRATIONNormal ServiceGirth and Miter Groove, Branch Connections: Max 1.5" in a 6" length of weld.Longitudinal Groove: None allowed

Severe CyclicGirth and Miter Groove, Branch Connections, and Longitudinal Groove: None allowed

SLAG INCLUSION, TUNGSTEN INCLUSION, OR ELONGATED INDICATIONNormal ServiceMax Individual Length: 0.290" Max Individual Width: 0.073" Max Cumulative Length: 0.580" in 6" of weld

Severe Cyclic ConditionsMax Individual Length: 0.048" Max Individual Width: 0.048" Max Cumulative Length: 0.145" in 1.740" of w

UNDERCUTTINGNormal Services: Not a factor for normal service

Severe Cyclic: Zero allowed

CONCAVE ROOT SURFACE (SUCK-UP)Normal Service and Severe Cyclic: Unacceptable if concave root is darker than the wall

INTERNAL POROSITYRelevant Indication: 0.016

Normal Services:Max Size of Random Internal Porosity: 0.036" Max Size of Isolated Internal Porosity: 0.048"Max Sum of diameters of Aligned Porosity: 0.145" in a 1.740" length of weldMax group length of Aligned Internal Porosity: 0.250"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 0.290"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.0"Severe Cyclic:Max size of Random Internal Porosity: 0.036" Max Size of Isolated Internal Porosity: 0.048"Max sum of diameters of Aligned Porosity: 0.145" in a 1.740" length of weldMax group length of Aligned Internal Porosity: 0.250"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 0.290"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.0"

Page 222: NDT Code Book Made Easy

s

B31.31.5" s/80 & Extra Strong - 0.200" Wall

PENETRAMETER SELECTIONNote: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Hole: 12 S/S Wire: 0.008 Esn. Wire: A2

F/S Hole: 10 F/S Wire: 0.006 Esn. Wire: A3Welds with reinforcement: S/S Hole: 15 S/S Wire: 0.010 Esn. Wire: A1 or B6

F/S Hole: 12 F/S Wire: 0.008 Esn. Wire: A2Maximum allowable reinforcement: 0.0625" Total of wall + reinforcement: 0.263"CRACKS AND LACK OF FUSIONNone Allowed

INCOMPLETE PENETRATIONNormal ServiceGirth and Miter Groove, Branch Connections: Max 1.5" in a 6" length of weld.Longitudinal Groove: None allowed

Severe CyclicGirth and Miter Groove, Branch Connections, and Longitudinal Groove: None allowed

SLAG INCLUSION, TUNGSTEN INCLUSION, OR ELONGATED INDICATIONNormal ServiceMax Individual Length: 0.400" Max Individual Width: 0.100" Max Cumulative Length: 0.800" in 6" of weld

Severe Cyclic ConditionsMax Individual Length: 0.067" Max Individual Width: 0.067" Max Cumulative Length: 0.200" in 2.400" of w

UNDERCUTTINGNormal Services: Not a factor for normal service

Severe Cyclic: Zero allowed

CONCAVE ROOT SURFACE (SUCK-UP)Normal Service and Severe Cyclic: Unacceptable if concave root is darker than the wall

INTERNAL POROSITYRelevant Indication: 0.016

Normal Services:Max Size of Random Internal Porosity: 0.050" Max Size of Isolated Internal Porosity: 0.067"Max Sum of diameters of Aligned Porosity: 0.200" in a 2.400" length of weldMax group length of Aligned Internal Porosity: 0.250"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 0.400"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.0"Severe Cyclic:Max size of Random Internal Porosity: 0.050" Max Size of Isolated Internal Porosity: 0.067"Max sum of diameters of Aligned Porosity: 0.200" in a 2.400" length of weldMax group length of Aligned Internal Porosity: 0.250"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 0.400"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.0"

Page 223: NDT Code Book Made Easy

s

B31.31.5" s/160 - 0.281" Wall

PENETRAMETER SELECTIONNote: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Hole: 15 S/S Wire: 0.010 Esn. Wire: A1 or B6

F/S Hole: 12 F/S Wire: 0.008 Esn. Wire: A2Welds with reinforcement: S/S Hole: 17 S/S Wire: 0.013 Esn. Wire: B5

F/S Hole: 15 F/S Wire: 0.010 Esn. Wire: A1 or B6Maximum allowable reinforcement: 0.125" Total of wall + reinforcement: 0.406"CRACKS AND LACK OF FUSIONNone Allowed

INCOMPLETE PENETRATIONNormal ServiceGirth and Miter Groove, Branch Connections: Max 1.5" in a 6" length of weld.Longitudinal Groove: None allowed

Severe CyclicGirth and Miter Groove, Branch Connections, and Longitudinal Groove: None allowed

SLAG INCLUSION, TUNGSTEN INCLUSION, OR ELONGATED INDICATIONNormal ServiceMax Individual Length: 0.562" Max Individual Width: 0.125" Max Cumulative Length: 1.124" in 6" of weld

Severe Cyclic ConditionsMax Individual Length: 0.094" Max Individual Width: 0.094" Max Cumulative Length: 0.281" in 3.372" of w

UNDERCUTTINGNormal Services: Not a factor for normal service

Severe Cyclic: Zero allowed

CONCAVE ROOT SURFACE (SUCK-UP)Normal Service and Severe Cyclic: Unacceptable if concave root is darker than the wall

INTERNAL POROSITYRelevant Indication: 0.031

Normal Services:Max Size of Random Internal Porosity: 0.105" Max Size of Isolated Internal Porosity: 0.141"Max Sum of diameters of Aligned Porosity: 0.422" in a 3.372" length of weldMax group length of Aligned Internal Porosity: 0.375"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 0.843"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.5"Severe Cyclic:Max size of Random Internal Porosity: 0.070" Max Size of Isolated Internal Porosity: 0.094"Max sum of diameters of Aligned Porosity: 0.281" in a 3.372" length of weldMax group length of Aligned Internal Porosity: 0.250"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 0.562"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.0"

Page 224: NDT Code Book Made Easy

s

B31.31.5" XX Strong - 0.400" Wall

PENETRAMETER SELECTIONNote: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Hole: 17 S/S Wire: 0.013 Esn. Wire: B5

F/S Hole: 15 F/S Wire: 0.010 Esn. Wire: A1 or B6Welds with reinforcement: S/S Hole: 20 S/S Wire: 0.016 Esn. Wire: B4

F/S Hole: 17 F/S Wire: 0.013 Esn. Wire: B5Maximum allowable reinforcement: 0.125" Total of wall + reinforcement: 0.525"CRACKS AND LACK OF FUSIONNone Allowed

INCOMPLETE PENETRATIONNormal ServiceGirth and Miter Groove, Branch Connections: Max 1.5" in a 6" length of weld.Longitudinal Groove: None allowed

Severe CyclicGirth and Miter Groove, Branch Connections, and Longitudinal Groove: None allowed

SLAG INCLUSION, TUNGSTEN INCLUSION, OR ELONGATED INDICATIONNormal ServiceMax Individual Length: 0.800" Max Individual Width: 0.125" Max Cumulative Length: 1.600" in 6" of weld

Severe Cyclic ConditionsMax Individual Length: 0.133" Max Individual Width: 0.094" Max Cumulative Length: 0.400" in 4.800" of w

UNDERCUTTINGNormal Services: Not a factor for normal service

Severe Cyclic: Zero allowed

CONCAVE ROOT SURFACE (SUCK-UP)Normal Service and Severe Cyclic: Unacceptable if concave root is darker than the wall

INTERNAL POROSITYRelevant Indication: 0.031

Normal Services:Max Size of Random Internal Porosity: 0.150" Max Size of Isolated Internal Porosity: 0.200"Max Sum of diameters of Aligned Porosity: 0.600" in a 4.800" length of weldMax group length of Aligned Internal Porosity: 0.375"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 1.200"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.5"Severe Cyclic:Max size of Random Internal Porosity: 0.100" Max Size of Isolated Internal Porosity: 0.133"Max sum of diameters of Aligned Porosity: 0.400" in a 4.800" length of weldMax group length of Aligned Internal Porosity: 0.250"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 0.800"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.0"

Page 225: NDT Code Book Made Easy

s

B31.32" s/40 & Std. - 0.154" Wall

PENETRAMETER SELECTIONNote: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Hole: 12 S/S Wire: 0.008 Esn. Wire: A2

F/S Hole: 10 F/S Wire: 0.006 Esn. Wire: A3Welds with reinforcement: S/S Hole: 12 S/S Wire: 0.008 Esn. Wire: A2

F/S Hole: 10 F/S Wire: 0.006 Esn. Wire: A3Maximum allowable reinforcement: 0.0625" Total of wall + reinforcement: 0.217"CRACKS AND LACK OF FUSIONNone Allowed

INCOMPLETE PENETRATIONNormal ServiceGirth and Miter Groove, Branch Connections: Max 1.5" in a 6" length of weld.Longitudinal Groove: None allowed

Severe CyclicGirth and Miter Groove, Branch Connections, and Longitudinal Groove: None allowed

SLAG INCLUSION, TUNGSTEN INCLUSION, OR ELONGATED INDICATIONNormal ServiceMax Individual Length: 0.308" Max Individual Width: 0.077" Max Cumulative Length: 0.616" in 6" of weld

Severe Cyclic ConditionsMax Individual Length: 0.051" Max Individual Width: 0.051" Max Cumulative Length: 0.154" in 1.848" of w

UNDERCUTTINGNormal Services: Not a factor for normal service

Severe Cyclic: Zero allowed

CONCAVE ROOT SURFACE (SUCK-UP)Normal Service and Severe Cyclic: Unacceptable if concave root is darker than the wall

INTERNAL POROSITYRelevant Indication: 0.016

Normal Services:Max Size of Random Internal Porosity: 0.039" Max Size of Isolated Internal Porosity: 0.051"Max Sum of diameters of Aligned Porosity: 0.154" in a 1.848" length of weldMax group length of Aligned Internal Porosity: 0.250"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 0.308"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.0"

Severe Cyclic:Max size of Random Internal Porosity: 0.039" Max Size of Isolated Internal Porosity: 0.051"Max sum of diameters of Aligned Porosity: 0.154" in a 1.848" length of weldMax group length of Aligned Internal Porosity: 0.250"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 0.308"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.0"

Page 226: NDT Code Book Made Easy

s

B31.32" s/80 and Extra Strong - 0.218" Wall

PENETRAMETER SELECTIONNote: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Hole: 12 S/S Wire: 0.008 Esn. Wire: A2

F/S Hole: 10 F/S Wire: 0.006 Esn. Wire: A3Welds with reinforcement: S/S Hole: 15 S/S Wire: 0.010 Esn. Wire: A1 or B6

F/S Hole: 12 F/S Wire: 0.008 Esn. Wire: A2Maximum allowable reinforcement: 0.0625" Total of wall + reinforcement: 0.281"CRACKS AND LACK OF FUSIONNone Allowed

INCOMPLETE PENETRATIONNormal ServiceGirth and Miter Groove, Branch Connections: Max 1.5" in a 6" length of weld.Longitudinal Groove: None allowed

Severe CyclicGirth and Miter Groove, Branch Connections, and Longitudinal Groove: None allowed

SLAG INCLUSION, TUNGSTEN INCLUSION, OR ELONGATED INDICATIONNormal ServiceMax Individual Length: 0.436" Max Individual Width: 0.109" Max Cumulative Length: 0.872" in 6" of weld

Severe Cyclic ConditionsMax Individual Length: 0.073" Max Individual Width: 0.073" Max Cumulative Length: 0.218" in 2.616" of w

UNDERCUTTINGNormal Services: Not a factor for normal service

Severe Cyclic: Zero allowed

CONCAVE ROOT SURFACE (SUCK-UP)Normal Service and Severe Cyclic: Unacceptable if concave root is darker than the wall

INTERNAL POROSITYRelevant Indication: 0.016

Normal Services:Max Size of Random Internal Porosity: 0.055" Max Size of Isolated Internal Porosity: 0.073"Max Sum of diameters of Aligned Porosity: 0.218" in a 2.616" length of weldMax group length of Aligned Internal Porosity: 0.250"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 0.436"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.0"

Severe Cyclic:Max size of Random Internal Porosity: 0.055" Max Size of Isolated Internal Porosity: 0.073"Max sum of diameters of Aligned Porosity: 0.218" in a 2.616" length of weldMax group length of Aligned Internal Porosity: 0.250"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 0.436"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.0"

Page 227: NDT Code Book Made Easy

s

B31.32" s/160 - 0.344" Wall

PENETRAMETER SELECTIONNote: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Hole: 15 S/S Wire: 0.010 Esn. Wire: A1 or B6

F/S Hole: 12 F/S Wire: 0.008 Esn. Wire: A2Welds with reinforcement: S/S Hole: 17 S/S Wire: 0.013 Esn. Wire: B5

F/S Hole: 15 F/S Wire: 0.010 Esn. Wire: A1 or B6Maximum allowable reinforcement: 0.125" Total of wall + reinforcement: 0.469"CRACKS AND LACK OF FUSIONNone Allowed

INCOMPLETE PENETRATIONNormal ServiceGirth and Miter Groove, Branch Connections: Max 1.5" in a 6" length of weld.Longitudinal Groove: None allowed

Severe CyclicGirth and Miter Groove, Branch Connections, and Longitudinal Groove: None allowed

SLAG INCLUSION, TUNGSTEN INCLUSION, OR ELONGATED INDICATIONNormal ServiceMax Individual Length: 0.688" Max Individual Width: 0.125" Max Cumulative Length: 1.376" in 6" of weld

Severe Cyclic ConditionsMax Individual Length: 0.115" Max Individual Width: 0.094" Max Cumulative Length: 0.344" in 4.128" of w

UNDERCUTTINGNormal Services: Not a factor for normal service

Severe Cyclic: Zero allowed

CONCAVE ROOT SURFACE (SUCK-UP)Normal Service and Severe Cyclic: Unacceptable if concave root is darker than the wall

INTERNAL POROSITYRelevant Indication: 0.031

Normal Services:Max Size of Random Internal Porosity: 0.129" Max Size of Isolated Internal Porosity: 0.172"Max Sum of diameters of Aligned Porosity: 0.516" in a 4.128" length of weldMax group length of Aligned Internal Porosity: 0.375"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 1.032"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.5"

Severe Cyclic:Max size of Random Internal Porosity: 0.086" Max Size of Isolated Internal Porosity: 0.115"Max sum of diameters of Aligned Porosity: 0.344" in a 4.128" length of weldMax group length of Aligned Internal Porosity: 0.250"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 0.688"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.0"

Page 228: NDT Code Book Made Easy

s

B31.32" XX Strong - 0.436" Wall

PENETRAMETER SELECTIONNote: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Hole: 17 S/S Wire: 0.013 Esn. Wire: B5

F/S Hole: 15 F/S Wire: 0.010 Esn. Wire: A1 or B6Welds with reinforcement: S/S Hole: 20 S/S Wire: 0.016 Esn. Wire: B4

F/S Hole: 17 F/S Wire: 0.013 Esn. Wire: B5Maximum allowable reinforcement: 0.125" Total of wall + reinforcement: 0.561"CRACKS AND LACK OF FUSIONNone Allowed

INCOMPLETE PENETRATIONNormal ServiceGirth and Miter Groove, Branch Connections: Max 1.5" in a 6" length of weld.Longitudinal Groove: None allowed

Severe CyclicGirth and Miter Groove, Branch Connections, and Longitudinal Groove: None allowed

SLAG INCLUSION, TUNGSTEN INCLUSION, OR ELONGATED INDICATIONNormal ServiceMax Individual Length: 0.872" Max Individual Width: 0.125" Max Cumulative Length: 1.744" in 6" of weld

Severe Cyclic ConditionsMax Individual Length: 0.145" Max Individual Width: 0.094" Max Cumulative Length: 0.436" in 5.232" of w

UNDERCUTTINGNormal Services: Not a factor for normal service

Severe Cyclic: Zero allowed

CONCAVE ROOT SURFACE (SUCK-UP)Normal Service and Severe Cyclic: Unacceptable if concave root is darker than the wall

INTERNAL POROSITYRelevant Indication: 0.031

Normal Services:Max Size of Random Internal Porosity: 0.164" Max Size of Isolated Internal Porosity: 0.218"Max Sum of diameters of Aligned Porosity: 0.654" in a 5.232" length of weldMax group length of Aligned Internal Porosity: 0.375"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 1.308"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.5"

Severe Cyclic:Max size of Random Internal Porosity: 0.109" Max Size of Isolated Internal Porosity: 0.145"Max sum of diameters of Aligned Porosity: 0.436" in a 5.232" length of weldMax group length of Aligned Internal Porosity: 0.250"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 0.872"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.0"

Page 229: NDT Code Book Made Easy

s

B31.33" s/10 - 0.120" Wall

PENETRAMETER SELECTIONNote: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Hole: 12 S/S Wire: 0.008 Esn. Wire: A2

F/S Hole: 10 F/S Wire: 0.006 Esn. Wire: A3Welds with reinforcement: S/S Hole: 12 S/S Wire: 0.008 Esn. Wire: A2

F/S Hole: 10 F/S Wire: 0.006 Esn. Wire: A3Maximum allowable reinforcement: 0.0625" Total of wall + reinforcement: 0.183"CRACKS AND LACK OF FUSIONNone Allowed

INCOMPLETE PENETRATIONNormal ServiceGirth and Miter Groove, Branch Connections: Max 1.5" in a 6" length of weld.Longitudinal Groove: None allowed

Severe CyclicGirth and Miter Groove, Branch Connections, and Longitudinal Groove: None allowed

SLAG INCLUSION, TUNGSTEN INCLUSION, OR ELONGATED INDICATIONNormal ServiceMax Individual Length: 0.240" Max Individual Width: 0.060" Max Cumulative Length: 0.480" in 6" of weld

Severe Cyclic ConditionsMax Individual Length: 0.040" Max Individual Width: 0.040" Max Cumulative Length: 0.120" in 1.440" of w

UNDERCUTTINGNormal Services: Not a factor for normal service

Severe Cyclic: Zero allowed

CONCAVE ROOT SURFACE (SUCK-UP)Normal Service and Severe Cyclic: Unacceptable if concave root is darker than the wall

INTERNAL POROSITYRelevant Indication: 0.013

Normal Services:Max Size of Random Internal Porosity: 0.030" Max Size of Isolated Internal Porosity: 0.040"Max Sum of diameters of Aligned Porosity: 0.120" in a 1.440" length of weldMax group length of Aligned Internal Porosity: 0.250"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 0.240"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.0"Max number of relevant internal porosity in a 6" length of of weld = 12

Severe Cyclic:Max size of Random Internal Porosity: 0.030" Max Size of Isolated Internal Porosity: 0.040"Max sum of diameters of Aligned Porosity: 0.120" in a 1.440" length of weldMax group length of Aligned Internal Porosity: 0.250"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 0.240"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.0"Max number of relevant internal porosity in a 6" length of weld = 12

Page 230: NDT Code Book Made Easy

s

B31.33" s/40 & Std. - 0.216" Wall

PENETRAMETER SELECTIONNote: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Hole: 12 S/S Wire: 0.008 Esn. Wire: A2

F/S Hole: 10 F/S Wire: 0.006 Esn. Wire: A3Welds with reinforcement: S/S Hole: 15 S/S Wire: 0.010 Esn. Wire: A1 or B6

F/S Hole: 12 F/S Wire: 0.008 Esn. Wire: A2Maximum allowable reinforcement: 0.0625" Total of wall + reinforcement: 0.279"CRACKS AND LACK OF FUSIONNone Allowed

INCOMPLETE PENETRATIONNormal ServiceGirth and Miter Groove, Branch Connections: Max 1.5" in a 6" length of weld.Longitudinal Groove: None allowed

Severe CyclicGirth and Miter Groove, Branch Connections, and Longitudinal Groove: None allowed

SLAG INCLUSION, TUNGSTEN INCLUSION, OR ELONGATED INDICATIONNormal ServiceMax Individual Length: 0.432" Max Individual Width: 0.108" Max Cumulative Length: 0.864" in 6" of weld

Severe Cyclic ConditionsMax Individual Length: 0.072" Max Individual Width: 0.072" Max Cumulative Length: 0.216" in 2.592" of w

UNDERCUTTINGNormal Services: Not a factor for normal service

Severe Cyclic: Zero allowed

CONCAVE ROOT SURFACE (SUCK-UP)Normal Service and Severe Cyclic: Unacceptable if concave root is darker than the wall

INTERNAL POROSITYRelevant Indication: 0.016

Normal Services:Max Size of Random Internal Porosity: 0.054" Max Size of Isolated Internal Porosity: 0.072"Max Sum of diameters of Aligned Porosity: 0.216" in a 2.592" length of weldMax group length of Aligned Internal Porosity: 0.250"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 0.432"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.0"

Severe Cyclic:Max size of Random Internal Porosity: 0.054" Max Size of Isolated Internal Porosity: 0.072"Max sum of diameters of Aligned Porosity: 0.216" in a 2.592" length of weldMax group length of Aligned Internal Porosity: 0.250"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 0.432"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.0"

Page 231: NDT Code Book Made Easy

s

B31.33" s/80 and Extra Strong - 0.300" Wall

PENETRAMETER SELECTIONNote: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Hole: 15 S/S Wire: 0.010 Esn. Wire: A1 or B6

F/S Hole: 12 F/S Wire: 0.008 Esn. Wire: A2Welds with reinforcement: S/S Hole: 17 S/S Wire: 0.013 Esn. Wire: B5

F/S Hole: 15 F/S Wire: 0.010 Esn. Wire: A1 or B6Maximum allowable reinforcement: 0.125" Total of wall + reinforcement: 0.425"CRACKS AND LACK OF FUSIONNone Allowed

INCOMPLETE PENETRATIONNormal ServiceGirth and Miter Groove, Branch Connections: Max 1.5" in a 6" length of weld.Longitudinal Groove: None allowed

Severe CyclicGirth and Miter Groove, Branch Connections, and Longitudinal Groove: None allowed

SLAG INCLUSION, TUNGSTEN INCLUSION, OR ELONGATED INDICATIONNormal ServiceMax Individual Length: 0.600" Max Individual Width: 0.125" Max Cumulative Length: 1.200" in 6" of weld

Severe Cyclic ConditionsMax Individual Length: 0.100" Max Individual Width: 0.094" Max Cumulative Length: 0.300" in 3.600" of w

UNDERCUTTINGNormal Services: Not a factor for normal service

Severe Cyclic: Zero allowed

CONCAVE ROOT SURFACE (SUCK-UP)Normal Service and Severe Cyclic: Unacceptable if concave root is darker than the wall

INTERNAL POROSITYRelevant Indication: 0.031

Normal Services:Max Size of Random Internal Porosity: 0.113" Max Size of Isolated Internal Porosity: 0.150"Max Sum of diameters of Aligned Porosity: 0.450" in a 3.600" length of weldMax group length of Aligned Internal Porosity: 0.375"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 0.900"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.5"

Severe Cyclic:Max size of Random Internal Porosity: 0.075" Max Size of Isolated Internal Porosity: 0.100"Max sum of diameters of Aligned Porosity: 0.300" in a 3.600" length of weldMax group length of Aligned Internal Porosity: 0.250"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 0.600"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.0"

Page 232: NDT Code Book Made Easy

s

B31.33" s/160 - 0.438" Wall

PENETRAMETER SELECTIONNote: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Hole: 17 S/S Wire: 0.013 Esn. Wire: B5

F/S Hole: 15 F/S Wire: 0.010 Esn. Wire: A1 or B6Welds with reinforcement: S/S Hole: 20 S/S Wire: 0.016 Esn. Wire: B4

F/S Hole: 17 F/S Wire: 0.013 Esn. Wire: B5Maximum allowable reinforcement: 0.125" Total of wall + reinforcement: 0.563"CRACKS AND LACK OF FUSIONNone Allowed

INCOMPLETE PENETRATIONNormal ServiceGirth and Miter Groove, Branch Connections: Max 1.5" in a 6" length of weld.Longitudinal Groove: None allowed

Severe CyclicGirth and Miter Groove, Branch Connections, and Longitudinal Groove: None allowed

SLAG INCLUSION, TUNGSTEN INCLUSION, OR ELONGATED INDICATIONNormal ServiceMax Individual Length: 0.876" Max Individual Width: 0.125" Max Cumulative Length: 1.752" in 6" of weld

Severe Cyclic ConditionsMax Individual Length: 0.146" Max Individual Width: 0.094" Max Cumulative Length: 0.438" in 5.256" of w

UNDERCUTTINGNormal Services: Not a factor for normal service

Severe Cyclic: Zero allowed

CONCAVE ROOT SURFACE (SUCK-UP)Normal Service and Severe Cyclic: Unacceptable if concave root is darker than the wall

INTERNAL POROSITYRelevant Indication: 0.031

Normal Services:Max Size of Random Internal Porosity: 0.164" Max Size of Isolated Internal Porosity: 0.219"Max Sum of diameters of Aligned Porosity: 0.657" in a 5.256" length of weldMax group length of Aligned Internal Porosity: 0.375"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 1.314"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.5"

Severe Cyclic:Max size of Random Internal Porosity: 0.110" Max Size of Isolated Internal Porosity: 0.146"Max sum of diameters of Aligned Porosity: 0.438" in a 5.256" length of weldMax group length of Aligned Internal Porosity: 0.250"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 0.876"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.0"

Page 233: NDT Code Book Made Easy

s

B31.33" XX Strong - 0.600" Wall

PENETRAMETER SELECTIONNote: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Hole: 20 S/S Wire: 0.016 Esn. Wire: B4

F/S Hole: 17 F/S Wire: 0.013 Esn. Wire: B5Welds with reinforcement: S/S Hole: 25 S/S Wire: 0.020 Esn. Wire: B3

F/S Hole: 20 F/S Wire: 0.016 Esn. Wire: B4Maximum allowable reinforcement: 0.156" Total of wall + reinforcement: 0.756"CRACKS AND LACK OF FUSIONNone Allowed

INCOMPLETE PENETRATIONNormal ServiceGirth and Miter Groove, Branch Connections: Max 1.5" in a 6" length of weld.Longitudinal Groove: None allowed

Severe CyclicGirth and Miter Groove, Branch Connections, and Longitudinal Groove: None allowed

SLAG INCLUSION, TUNGSTEN INCLUSION, OR ELONGATED INDICATIONNormal ServiceMax Individual Length: 1.200" Max Individual Width: 0.125" Max Cumulative Length: 2.400" in 6" of weld

Severe Cyclic ConditionsMax Individual Length: 0.200" Max Individual Width: 0.094" Max Cumulative Length: 0.600" in 7.200" of w

UNDERCUTTINGNormal Services: Not a factor for normal service

Severe Cyclic: Zero allowed

CONCAVE ROOT SURFACE (SUCK-UP)Normal Service and Severe Cyclic: Unacceptable if concave root is darker than the wall

INTERNAL POROSITYRelevant Indication: 0.031

Normal Services:Max Size of Random Internal Porosity: 0.225" Max Size of Isolated Internal Porosity: 0.300"Max Sum of diameters of Aligned Porosity: 0.900" in a 7.200" length of weldMax group length of Aligned Internal Porosity: 0.375"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 1.5"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.5"

Severe Cyclic:Max size of Random Internal Porosity: 0.150" Max Size of Isolated Internal Porosity: 0.200"Max sum of diameters of Aligned Porosity: 0.600" in a 7.200" length of weldMax group length of Aligned Internal Porosity: 0.250"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 1.0"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.0"

Page 234: NDT Code Book Made Easy

s

B31.34" s/10 - 0.120" Wall

PENETRAMETER SELECTIONNote: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Hole: 12 S/S Wire: 0.008 Esn. Wire: A2

F/S Hole: 10 F/S Wire: 0.006 Esn. Wire: A3Welds with reinforcement: S/S Hole: 12 S/S Wire: 0.008 Esn. Wire: A2

F/S Hole: 10 F/S Wire: 0.006 Esn. Wire: A3Maximum allowable reinforcement: 0.0625" Total of wall + reinforcement: 0.183"CRACKS AND LACK OF FUSIONNone Allowed

INCOMPLETE PENETRATIONNormal ServiceGirth and Miter Groove, Branch Connections: Max 1.5" in a 6" length of weld.Longitudinal Groove: None allowed

Severe CyclicGirth and Miter Groove, Branch Connections, and Longitudinal Groove: None allowed

SLAG INCLUSION, TUNGSTEN INCLUSION, OR ELONGATED INDICATIONNormal ServiceMax Individual Length: 0.240" Max Individual Width: 0.060" Max Cumulative Length: 0.480" in 6" of weld

Severe Cyclic ConditionsMax Individual Length: 0.040" Max Individual Width: 0.040" Max Cumulative Length: 0.120" in 1.440" of w

UNDERCUTTINGNormal Services: Not a factor for normal service

Severe Cyclic: Zero allowed

CONCAVE ROOT SURFACE (SUCK-UP)Normal Service and Severe Cyclic: Unacceptable if concave root is darker than the wall

INTERNAL POROSITYRelevant Indication: 0.013

Normal Services:Max Size of Random Internal Porosity: 0.030" Max Size of Isolated Internal Porosity: 0.040"Max Sum of diameters of Aligned Porosity: 0.120" in a 1.440" length of weldMax group length of Aligned Internal Porosity: 0.250"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 0.240"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.0"Max number of relevant internal porosity in a 6" length of weld = 12

Severe Cyclic:Max size of Random Internal Porosity: 0.030" Max Size of Isolated Internal Porosity: 0.040"Max sum of diameters of Aligned Porosity: 0.120" in a 1.440" length of weldMax group length of Aligned Internal Porosity: 0.250"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 0.240"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.0"Max number of relevant internal porosity in a 6" length of weld = 12

Page 235: NDT Code Book Made Easy

s

B31.34" s/40 & Std. - 0.237" Wall

PENETRAMETER SELECTIONNote: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Hole: 12 S/S Wire: 0.008 Esn. Wire: A2

F/S Hole: 10 F/S Wire: 0.006 Esn. Wire: A3Welds with reinforcement: S/S Hole: 15 S/S Wire: 0.010 Esn. Wire: A1 or B6

F/S Hole: 12 F/S Wire: 0.008 Esn. Wire: A2Maximum allowable reinforcement: 0.0625" Total of wall + reinforcement: 0.183"CRACKS AND LACK OF FUSIONNone Allowed

INCOMPLETE PENETRATIONNormal ServiceGirth and Miter Groove, Branch Connections: Max 1.5" in a 6" length of weld.Longitudinal Groove: None allowed

Severe CyclicGirth and Miter Groove, Branch Connections, and Longitudinal Groove: None allowed

SLAG INCLUSION, TUNGSTEN INCLUSION, OR ELONGATED INDICATIONNormal ServiceMax Individual Length: 0.474" Max Individual Width: 0.119" Max Cumulative Length: 0.948" in 6" of weld

Severe Cyclic ConditionsMax Individual Length: 0.079" Max Individual Width: 0.079" Max Cumulative Length: 0.237" in 2.844" of w

UNDERCUTTINGNormal Services: Not a factor for normal service

Severe Cyclic: Zero allowed

CONCAVE ROOT SURFACE (SUCK-UP)Normal Service and Severe Cyclic: Unacceptable if concave root is darker than the wall

INTERNAL POROSITYRelevant Indication: 0.016

Normal Services:

Max Size of Random Internal Porosity: 0.059" Max Size of Isolated Internal Porosity: 0.079"Max Sum of diameters of Aligned Porosity: 0.237" in a 2.844" length of weldMax group length of Aligned Internal Porosity: 0.250"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 0.474"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.0"

Severe Cyclic:Max size of Random Internal Porosity: 0.059" Max Size of Isolated Internal Porosity: 0.079"Max sum of diameters of Aligned Porosity: 0.237" in a 2.844" length of weldMax group length of Aligned Internal Porosity: 0.250"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 0.474"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.0"

Page 236: NDT Code Book Made Easy

s

B31.34" s/80 and Extra Strong - 0.337" Wall

PENETRAMETER SELECTIONNote: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Hole: 15 S/S Wire: 0.010 Esn. Wire: A1 or B6

F/S Hole: 12 F/S Wire: 0.008 Esn. Wire: A2Welds with reinforcement: S/S Hole: 17 S/S Wire: 0.013 Esn. Wire: B5

F/S Hole: 15 F/S Wire: 0.010 Esn. Wire: A1 or B6Maximum allowable reinforcement: 0.125" Total of wall + reinforcement: 0.462"CRACKS AND LACK OF FUSIONNone Allowed

INCOMPLETE PENETRATIONNormal ServiceGirth and Miter Groove, Branch Connections: Max 1.5" in a 6" length of weld.Longitudinal Groove: None allowed

Severe CyclicGirth and Miter Groove, Branch Connections, and Longitudinal Groove: None allowed

SLAG INCLUSION, TUNGSTEN INCLUSION, OR ELONGATED INDICATIONNormal ServiceMax Individual Length: 0.674" Max Individual Width: 0.125" Max Cumulative Length: 1.348" in 6" of weld

Severe Cyclic ConditionsMax Individual Length: 0.112" Max Individual Width: 0.094" Max Cumulative Length: 0.337" in 4.044" of w

UNDERCUTTINGNormal Services: Not a factor for normal service

Severe Cyclic: Zero allowed

CONCAVE ROOT SURFACE (SUCK-UP)Normal Service and Severe Cyclic: Unacceptable if concave root is darker than the wall

INTERNAL POROSITYRelevant Indication: 0.031

Normal Services:

Max Size of Random Internal Porosity: 0.126" Max Size of Isolated Internal Porosity: 0.169"Max Sum of diameters of Aligned Porosity: 0.506" in a 4.044" length of weldMax group length of Aligned Internal Porosity: 0.375"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 1.011"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.5"

Severe Cyclic:Max size of Random Internal Porosity: 0.084" Max Size of Isolated Internal Porosity: 0.112"Max sum of diameters of Aligned Porosity: 0.337" in a 4.044" length of weldMax group length of Aligned Internal Porosity: 0.250"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 0.674"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.0"

Page 237: NDT Code Book Made Easy

s

B31.34" s/120 - 0.438" Wall

PENETRAMETER SELECTIONNote: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Hole: 17 S/S Wire: 0.013 Esn. Wire: B5

F/S Hole: 15 F/S Wire: 0.010 Esn. Wire: A1 or B6Welds with reinforcement: S/S Hole: 20 S/S Wire: 0.016 Esn. Wire: B4

F/S Hole: 17 F/S Wire: 0.013 Esn. Wire: B5Maximum allowable reinforcement: 0.125" Total of wall + reinforcement: 0.563"CRACKS AND LACK OF FUSIONNone Allowed

INCOMPLETE PENETRATIONNormal ServiceGirth and Miter Groove, Branch Connections: Max 1.5" in a 6" length of weld.Longitudinal Groove: None allowed

Severe CyclicGirth and Miter Groove, Branch Connections, and Longitudinal Groove: None allowed

SLAG INCLUSION, TUNGSTEN INCLUSION, OR ELONGATED INDICATIONNormal ServiceMax Individual Length: 0.876" Max Individual Width: 0.125" Max Cumulative Length: 1.752" in 6" of weld

Severe Cyclic ConditionsMax Individual Length: 0.146" Max Individual Width: 0.094" Max Cumulative Length: 0.438" in 5.256" of w

UNDERCUTTINGNormal Services: Not a factor for normal service

Severe Cyclic: Zero allowed

CONCAVE ROOT SURFACE (SUCK-UP)Normal Service and Severe Cyclic: Unacceptable if concave root is darker than the wall

INTERNAL POROSITYRelevant Indication: 0.031

Normal Services:

Max Size of Random Internal Porosity: 0.164" Max Size of Isolated Internal Porosity: 0.219"Max Sum of diameters of Aligned Porosity: 0.657" in a 5.256" length of weldMax group length of Aligned Internal Porosity: 0.375"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 1.314"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.5"

Severe Cyclic:Max size of Random Internal Porosity: 0.110" Max Size of Isolated Internal Porosity: 0.146"Max sum of diameters of Aligned Porosity: 0.438" in a 5.256" length of weldMax group length of Aligned Internal Porosity: 0.250"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 0.876"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.0"

Page 238: NDT Code Book Made Easy

s

B31.34" s/160 - 0.531" Wall

PENETRAMETER SELECTIONNote: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Hole: 20 S/S Wire: 0.016 Esn. Wire: B4

F/S Hole: 17 F/S Wire: 0.013 Esn. Wire: B5Welds with reinforcement: S/S Hole: 20 S/S Wire: 0.016 Esn. Wire: B4

F/S Hole: 17 F/S Wire: 0.013 Esn. Wire: B5Maximum allowable reinforcement: 0.156" Total of wall + reinforcement: 0.687"CRACKS AND LACK OF FUSIONNone Allowed

INCOMPLETE PENETRATIONNormal ServiceGirth and Miter Groove, Branch Connections: Max 1.5" in a 6" length of weld.Longitudinal Groove: None allowed

Severe CyclicGirth and Miter Groove, Branch Connections, and Longitudinal Groove: None allowed

SLAG INCLUSION, TUNGSTEN INCLUSION, OR ELONGATED INDICATIONNormal ServiceMax Individual Length: 1.062" Max Individual Width: 0.125" Max Cumulative Length: 2.124" in 6" of weld

Severe Cyclic ConditionsMax Individual Length: 0.177" Max Individual Width: 0.094" Max Cumulative Length: 0.531" in 6.372" of w

UNDERCUTTINGNormal Services: Not a factor for normal service

Severe Cyclic: Zero allowed

CONCAVE ROOT SURFACE (SUCK-UP)Normal Service and Severe Cyclic: Unacceptable if concave root is darker than the wall

INTERNAL POROSITYRelevant Indication: 0.031

Normal Services:

Max Size of Random Internal Porosity: 0.199" Max Size of Isolated Internal Porosity: 0.266"Max Sum of diameters of Aligned Porosity: 0.797" in a 6.372" length of weldMax group length of Aligned Internal Porosity: 0.375"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 1.5"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.5"

Severe Cyclic:Max size of Random Internal Porosity: 0.133" Max Size of Isolated Internal Porosity: 0.177"Max sum of diameters of Aligned Porosity: 0.531" in a 6.372" length of weldMax group length of Aligned Internal Porosity: 0.250"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 1.0"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.0"

Page 239: NDT Code Book Made Easy

s

B31.34" XX Strong - 0.674" Wall

PENETRAMETER SELECTIONNote: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Hole: 20 S/S Wire: 0.016 Esn. Wire: B4

F/S Hole: 17 F/S Wire: 0.013 Esn. Wire: B5Welds with reinforcement: S/S Hole: 25 S/S Wire: 0.020 Esn. Wire: B3

F/S Hole: 20 F/S Wire: 0.016 Esn. Wire: B4Maximum allowable reinforcement: 0.156" Total of wall + reinforcement: 0.830"CRACKS AND LACK OF FUSIONNone Allowed

INCOMPLETE PENETRATIONNormal ServiceGirth and Miter Groove, Branch Connections: Max 1.5" in a 6" length of weld.Longitudinal Groove: None allowed

Severe CyclicGirth and Miter Groove, Branch Connections, and Longitudinal Groove: None allowed

SLAG INCLUSION, TUNGSTEN INCLUSION, OR ELONGATED INDICATIONNormal ServiceMax Individual Length: 1.348" Max Individual Width: 0.125" Max Cumulative Length: 2.696" in 6" of weld

Severe Cyclic ConditionsMax Individual Length: 0.225" Max Individual Width: 0.094" Max Cumulative Length: 0.674" in 8.008" of w

UNDERCUTTINGNormal Services: Not a factor for normal service

Severe Cyclic: Zero allowed

CONCAVE ROOT SURFACE (SUCK-UP)Normal Service and Severe Cyclic: Unacceptable if concave root is darker than the wall

INTERNAL POROSITYRelevant Indication: 0.031

Normal Services:

Max Size of Random Internal Porosity: 0.234" Max Size of Isolated Internal Porosity: 0.337"Max Sum of diameters of Aligned Porosity: 1.011" in a 8.088" length of weldMax group length of Aligned Internal Porosity: 0.375"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 1.5"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.5"

Severe Cyclic:Max size of Random Internal Porosity: 0.156" Max Size of Isolated Internal Porosity: 0.225"Max sum of diameters of Aligned Porosity: 0.674" in a 8.088" length of weldMax group length of Aligned Internal Porosity: 0.250"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 1.0"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.0"

Page 240: NDT Code Book Made Easy

s

B31.36" s/10 = 0.134" Wall

PENETRAMETER SELECTIONNote: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Hole: 12 S/S Wire: 0.008 Esn. Wire: A2

F/S Hole: 10 F/S Wire: 0.006 Esn. Wire: A3Welds with reinforcement: S/S Hole: 12 S/S Wire: 0.008 Esn. Wire: A2

F/S Hole: 10 F/S Wire: 0.006 Esn. Wire: A3Maximum allowable reinforcement: 0.0625" Total of wall + reinforcement: 0.197"CRACKS AND LACK OF FUSIONNone Allowed

INCOMPLETE PENETRATIONNormal ServiceGirth and Miter Groove, Branch Connections: Max 1.5" in a 6" length of weld.Longitudinal Groove: None allowed

Severe CyclicGirth and Miter Groove, Branch Connections, and Longitudinal Groove: None allowed

SLAG INCLUSION, TUNGSTEN INCLUSION, OR ELONGATED INDICATIONNormal ServiceMax Individual Length: 0.268" Max Individual Width: 0.067" Max Cumulative Length: 0.536" in 6" of weld

Severe Cyclic ConditionsMax Individual Length: 0.045" Max Individual Width: 0.045" Max Cumulative Length: 0.134" in 1.608" of w

UNDERCUTTINGNormal Services: Not a factor for normal service

Severe Cyclic: Zero allowed

CONCAVE ROOT SURFACE (SUCK-UP)Normal Service and Severe Cyclic: Unacceptable if concave root is darker than the wall

INTERNAL POROSITYRelevant Indication: 0.016

Normal Services:

Max Size of Random Internal Porosity: 0.034" Max Size of Isolated Internal Porosity: 0.045"Max Sum of diameters of Aligned Porosity: 0.134" in a 1.608" length of weldMax group length of Aligned Internal Porosity: 0.250"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 0.268"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.0"

Severe Cyclic:Max size of Random Internal Porosity: 0.034" Max Size of Isolated Internal Porosity: 0.045"Max sum of diameters of Aligned Porosity: 0.134" in a 1.608" length of weldMax group length of Aligned Internal Porosity: 0.250"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 0.268"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.0"

Page 241: NDT Code Book Made Easy

s

B31.36" s/40 & Std. - 0.280" Wall

PENETRAMETER SELECTIONNote: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Hole: 15 S/S Wire: 0.010 Esn. Wire: A1 or B6

F/S Hole: 12 F/S Wire: 0.008 Esn. Wire: A2Welds with reinforcement: S/S Hole: 17 S/S Wire: 0.013 Esn. Wire: B5

F/S Hole: 15 F/S Wire: 0.010 Esn. Wire: A1 or B6Maximum allowable reinforcement: 0.125" Total of wall + reinforcement: 0.405"CRACKS AND LACK OF FUSIONNone Allowed

INCOMPLETE PENETRATIONNormal ServiceGirth and Miter Groove, Branch Connections: Max 1.5" in a 6" length of weld.Longitudinal Groove: None allowed

Severe CyclicGirth and Miter Groove, Branch Connections, and Longitudinal Groove: None allowed

SLAG INCLUSION, TUNGSTEN INCLUSION, OR ELONGATED INDICATIONNormal ServiceMax Individual Length: 0.560" Max Individual Width: 0.125" Max Cumulative Length: 1.120" in 6" of weld

Severe Cyclic ConditionsMax Individual Length: 0.093" Max Individual Width: 0.093" Max Cumulative Length: 0.280" in 3.360" of w

UNDERCUTTINGNormal Services: Not a factor for normal service

Severe Cyclic: Zero allowed

CONCAVE ROOT SURFACE (SUCK-UP)Normal Service and Severe Cyclic: Unacceptable if concave root is darker than the wall

INTERNAL POROSITYRelevant Indication: 0.031

Normal Services:

Max Size of Random Internal Porosity: 0.105" Max Size of Isolated Internal Porosity: 0.140"Max Sum of diameters of Aligned Porosity: 0.420" in a 3.360" length of weldMax group length of Aligned Internal Porosity: 0.375"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 0.840"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.5"

Severe Cyclic:Max size of Random Internal Porosity: 0.070" Max Size of Isolated Internal Porosity: 0.093"Max sum of diameters of Aligned Porosity: 0.280" in a 3.360" length of weldMax group length of Aligned Internal Porosity: 0.250"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 0.560"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.0"

Page 242: NDT Code Book Made Easy

s

B31.36" s/80 & Extra Strong - 0.432" Wall

PENETRAMETER SELECTIONNote: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Hole: 17 S/S Wire: 0.013 Esn. Wire: B5

F/S Hole: 15 F/S Wire: 0.010 Esn. Wire: A1 or B6Welds with reinforcement: S/S Hole: 20 S/S Wire: 0.016 Esn. Wire: B4

F/S Hole: 17 F/S Wire: 0.013 Esn. Wire: B5Maximum allowable reinforcement: 0.125" Total of wall + reinforcement: 0.557"CRACKS AND LACK OF FUSIONNone Allowed

INCOMPLETE PENETRATIONNormal ServiceGirth and Miter Groove, Branch Connections: Max 1.5" in a 6" length of weld.Longitudinal Groove: None allowed

Severe CyclicGirth and Miter Groove, Branch Connections, and Longitudinal Groove: None allowed

SLAG INCLUSION, TUNGSTEN INCLUSION, OR ELONGATED INDICATIONNormal ServiceMax Individual Length: 0.864" Max Individual Width: 0.125" Max Cumulative Length: 1.728" in 6" of weld

Severe Cyclic ConditionsMax Individual Length: 0.144" Max Individual Width: 0.094" Max Cumulative Length: 0.432" in 5.184" of w

UNDERCUTTINGNormal Services: Not a factor for normal service

Severe Cyclic: Zero allowed

CONCAVE ROOT SURFACE (SUCK-UP)Normal Service and Severe Cyclic: Unacceptable if concave root is darker than the wall

INTERNAL POROSITYRelevant Indication: 0.031

Normal Services:

Max Size of Random Internal Porosity: 0.162" Max Size of Isolated Internal Porosity: 0.216"Max Sum of diameters of Aligned Porosity: 0.648" in a 5.184" length of weldMax group length of Aligned Internal Porosity: 0.375"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 1.296"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.5"

Severe Cyclic:Max size of Random Internal Porosity: 0.108" Max Size of Isolated Internal Porosity: 0.144"Max sum of diameters of Aligned Porosity: 0.432" in a 5.184" length of weldMax group length of Aligned Internal Porosity: 0.250"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 0.864"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.0"

Page 243: NDT Code Book Made Easy

s

B31.36" s/160 - 0.719" Wall

PENETRAMETER SELECTIONNote: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Hole: 20 S/S Wire: 0.016 Esn. Wire: B4

F/S Hole: 17 F/S Wire: 0.013 Esn. Wire: B5Welds with reinforcement: S/S Hole: 25 S/S Wire: 0.020 Esn. Wire: B3

F/S Hole: 20 F/S Wire: 0.016 Esn. Wire: B4Maximum allowable reinforcement: 0.156" Total of wall + reinforcement: 0.875"CRACKS AND LACK OF FUSIONNone Allowed

INCOMPLETE PENETRATIONNormal ServiceGirth and Miter Groove, Branch Connections: Max 1.5" in a 6" length of weld.Longitudinal Groove: None allowed

Severe CyclicGirth and Miter Groove, Branch Connections, and Longitudinal Groove: None allowed

SLAG INCLUSION, TUNGSTEN INCLUSION, OR ELONGATED INDICATIONNormal ServiceMax Individual Length: 1.438" Max Individual Width: 0.125" Max Cumulative Length: 2.876" in 6" of weld

Severe Cyclic ConditionsMax Individual Length: 0.240" Max Individual Width: 0.094" Max Cumulative Length: 0.719" in 8.628" of w

UNDERCUTTINGNormal Services: Not a factor for normal service

Severe Cyclic: Zero allowed

CONCAVE ROOT SURFACE (SUCK-UP)Normal Service and Severe Cyclic: Unacceptable if concave root is darker than the wall

INTERNAL POROSITYRelevant Indication: 0.031

Normal Services:

Max Size of Random Internal Porosity: 0.234" Max Size of Isolated Internal Porosity: 0.360"Max Sum of diameters of Aligned Porosity: 1.079" in a 8.628" length of weldMax group length of Aligned Internal Porosity: 0.375"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 1.5"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.5"

Severe Cyclic:Max size of Random Internal Porosity: 0.156" Max Size of Isolated Internal Porosity: 0.240"Max sum of diameters of Aligned Porosity: 0.719" in a 8.628" length of weldMax group length of Aligned Internal Porosity: 0.250"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 1.0"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.0"

Page 244: NDT Code Book Made Easy

s

B31.36" XX Strong - 0.864" Wall

PENETRAMETER SELECTIONNote: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Hole: 25 S/S Wire: 0.020 Esn. Wire: B3

F/S Hole: 20 F/S Wire: 0.016 Esn. Wire: B4Welds with reinforcement: S/S Hole: 30 S/S Wire: 0.025 Esn. Wire: B2

F/S Hole: 25 F/S Wire: 0.020 Esn. Wire: B3Maximum allowable reinforcement: 0.156" Total of wall + reinforcement: 1.020"CRACKS AND LACK OF FUSIONNone Allowed

INCOMPLETE PENETRATIONNormal ServiceGirth and Miter Groove, Branch Connections: Max 1.5" in a 6" length of weld.Longitudinal Groove: None allowed

Severe CyclicGirth and Miter Groove, Branch Connections, and Longitudinal Groove: None allowed

SLAG INCLUSION, TUNGSTEN INCLUSION, OR ELONGATED INDICATIONNormal ServiceMax Individual Length: 1.728" Max Individual Width: 0.125" Max Cumulative Length: 3.456" in 6" of weld

Severe Cyclic ConditionsMax Individual Length: 0.288" Max Individual Width: 0.094" Max Cumulative Length: 0.864" in 10.368"/w

UNDERCUTTINGNormal Services: Not a factor for normal service

Severe Cyclic: Zero allowed

CONCAVE ROOT SURFACE (SUCK-UP)Normal Service and Severe Cyclic: Unacceptable if concave root is darker than the wall

INTERNAL POROSITYRelevant Indication: 0.031

Normal Services:

Max Size of Random Internal Porosity: 0.234" Max Size of Isolated Internal Porosity: 0.375"Max Sum of diameters of Aligned Porosity: 1.296" in a 10.368" length of weldMax group length of Aligned Internal Porosity: 0.432"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 1.5"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.5"

Severe Cyclic:Max size of Random Internal Porosity: 0.156" Max Size of Isolated Internal Porosity: 0.250"Max sum of diameters of Aligned Porosity: 0.864" in a 10.368" length of weldMax group length of Aligned Internal Porosity: 0.288"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 1.0"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.0"

Page 245: NDT Code Book Made Easy

s

B31.38" s/10 - 0.148" Wall

PENETRAMETER SELECTIONNote: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Hole: 12 S/S Wire: 0.008 Esn. Wire: A2

F/S Hole: 10 F/S Wire: 0.006 Esn. Wire: A3Welds with reinforcement: S/S Hole: 12 S/S Wire: 0.008 Esn. Wire: A2

F/S Hole: 10 F/S Wire: 0.006 Esn. Wire: A3Maximum allowable reinforcement: 0.0625" Total of wall + reinforcement: 0.211"CRACKS AND LACK OF FUSIONNone Allowed

INCOMPLETE PENETRATIONNormal ServiceGirth and Miter Groove, Branch Connections: Max 1.5" in a 6" length of weld.Longitudinal Groove: None allowed

Severe CyclicGirth and Miter Groove, Branch Connections, and Longitudinal Groove: None allowed

SLAG INCLUSION, TUNGSTEN INCLUSION, OR ELONGATED INDICATIONNormal ServiceMax Individual Length: 0.296" Max Individual Width: 0.074" Max Cumulative Length: 0.592" in 6" of weld

Severe Cyclic ConditionsMax Individual Length: 0.049" Max Individual Width: 0.049" Max Cumulative Length: 0.148" in 1.776" of w

UNDERCUTTINGNormal Services: Not a factor for normal service

Severe Cyclic: Zero allowed

CONCAVE ROOT SURFACE (SUCK-UP)Normal Service and Severe Cyclic: Unacceptable if concave root is darker than the wall

INTERNAL POROSITYRelevant Indication: 0.016

Normal Services:

Max Size of Random Internal Porosity: 0.037" Max Size of Isolated Internal Porosity: 0.049"Max Sum of diameters of Aligned Porosity: 0.148" in a 1.776" length of weldMax group length of Aligned Internal Porosity: 0.250"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 0.296"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.0"

Severe Cyclic:Max size of Random Internal Porosity: 0.037" Max Size of Isolated Internal Porosity: 0.049"Max sum of diameters of Aligned Porosity: 0.148" in a 1.776" length of weldMax group length of Aligned Internal Porosity: 0.250"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 0.296"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.0"

Page 246: NDT Code Book Made Easy

s

B31.38" s/40 & Std. - 0.322" Wall

PENETRAMETER SELECTIONNote: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Hole: 15 S/S Wire: 0.010 Esn. Wire: A1 or B6

F/S Hole: 12 F/S Wire: 0.008 Esn. Wire: A2Welds with reinforcement: S/S Hole: 17 S/S Wire: 0.013 Esn. Wire: B5

F/S Hole: 15 F/S Wire: 0.010 Esn. Wire: A1 or B6Maximum allowable reinforcement: 0.125" Total of wall + reinforcement: 0.447"CRACKS AND LACK OF FUSIONNone Allowed

INCOMPLETE PENETRATIONNormal ServiceGirth and Miter Groove, Branch Connections: Max 1.5" in a 6" length of weld.Longitudinal Groove: None allowed

Severe CyclicGirth and Miter Groove, Branch Connections, and Longitudinal Groove: None allowed

SLAG INCLUSION, TUNGSTEN INCLUSION, OR ELONGATED INDICATIONNormal ServiceMax Individual Length: 0.644" Max Individual Width: 0.125" Max Cumulative Length: 1.288" in 6" of weld

Severe Cyclic ConditionsMax Individual Length: 0.107" Max Individual Width: 0.094" Max Cumulative Length: 0.322" in 3.864" of w

UNDERCUTTINGNormal Services: Not a factor for normal service

Severe Cyclic: Zero allowed

CONCAVE ROOT SURFACE (SUCK-UP)Normal Service and Severe Cyclic: Unacceptable if concave root is darker than the wall

INTERNAL POROSITYRelevant Indication: 0.031

Normal Services:

Max Size of Random Internal Porosity: 0.121" Max Size of Isolated Internal Porosity: 0.161"Max Sum of diameters of Aligned Porosity: 0.483" in a 3.864" length of weldMax group length of Aligned Internal Porosity: 0.375"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 0.966"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.5"

Severe Cyclic:Max size of Random Internal Porosity: 0.081" Max Size of Isolated Internal Porosity: 0.107"Max sum of diameters of Aligned Porosity: 0.322" in a 3.864" length of weldMax group length of Aligned Internal Porosity: 0.250"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 0.644"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.0"

Page 247: NDT Code Book Made Easy

s

B31.38" s/80 & Extra Strong - 0.500" Wall

Penetrameter SelectionNote: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Hole: 17 S/S Wire: 0.013 Esn. Wire: B5

F/S Hole: 15 F/S Wire: 0.010 Esn. Wire: A1 or B6Welds with reinforcement: S/S Hole: 20 S/S Wire: 0.016 Esn. Wire: B4

F/S Hole: 17 F/S Wire: 0.013 Esn. Wire: B5Maximum allowable reinforcement: 0.125" Total of wall + reinforcement: 0.625"CRACKS AND LACK OF FUSIONNone Allowed

INCOMPLETE PENETRATIONNormal ServiceGirth and Miter Groove, Branch Connections: Max 1.5" in a 6" length of weld.Longitudinal Groove: None allowed

Severe CyclicGirth and Miter Groove, Branch Connections, and Longitudinal Groove: None allowed

SLAG INCLUSION, TUNGSTEN INCLUSION, OR ELONGATED INDICATIONNormal ServiceMax Individual Length: 1.000" Max Individual Width: 0.125" Max Cumulative Length: 2.000" in 6" of weld

Severe Cyclic ConditionsMax Individual Length: 0.167" Max Individual Width: 0.094" Max Cumulative Length: 0.500" in 6.000" of w

UNDERCUTTINGNormal Services: Not a factor for normal service

Severe Cyclic: Zero allowed

CONCAVE ROOT SURFACE (SUCK-UP)Normal Service and Severe Cyclic: Unacceptable if concave root is darker than the wall

INTERNAL POROSITYRelevant Indication: 0.031

Normal Services:

Max Size of Random Internal Porosity: 0.188" Max Size of Isolated Internal Porosity: 0.250"Max Sum of diameters of Aligned Porosity: 0.750" in a 6.000" length of weldMax group length of Aligned Internal Porosity: 0.375"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 1.500"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.5"

Severe Cyclic:Max size of Random Internal Porosity: 0.125" Max Size of Isolated Internal Porosity: 0.167"Max sum of diameters of Aligned Porosity: 0.500" in a 6.000" length of weldMax group length of Aligned Internal Porosity: 0.250"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 1.000"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.0"

Page 248: NDT Code Book Made Easy

s

B31.38" s/120 - 0.719" Wall

PENETRAMETER SELECTIONNote: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Hole: 20 S/S Wire: 0.016 Esn. Wire: B4

F/S Hole: 17 F/S Wire: 0.013 Esn. Wire: B5Welds with reinforcement: S/S Hole: 25 S/S Wire: 0.020 Esn. Wire: B3

F/S Hole: 20 F/S Wire: 0.016 Esn. Wire: B4Maximum allowable reinforcement: 0.156" Total of wall + reinforcement: 0.875"CRACKS AND LACK OF FUSIONNone Allowed

INCOMPLETE PENETRATIONNormal ServiceGirth and Miter Groove, Branch Connections: Max 1.5" in a 6" length of weld.Longitudinal Groove: None allowed

Severe CyclicGirth and Miter Groove, Branch Connections, and Longitudinal Groove: None allowed

SLAG INCLUSION, TUNGSTEN INCLUSION, OR ELONGATED INDICATIONNormal ServiceMax Individual Length: 1.438" Max Individual Width: 0.125" Max Cumulative Length: 2.876" in 6" of weld

Severe Cyclic ConditionsMax Individual Length: 0.240" Max Individual Width: 0.094" Max Cumulative Length: 0.719" in 8.628" of w

UNDERCUTTINGNormal Services: Not a factor for normal service

Severe Cyclic: Zero allowed

CONCAVE ROOT SURFACE (SUCK-UP)Normal Service and Severe Cyclic: Unacceptable if concave root is darker than the wall

INTERNAL POROSITYRelevant Indication: 0.031

Normal Services:

Max Size of Random Internal Porosity: 0.234" Max Size of Isolated Internal Porosity: 0.360"Max Sum of diameters of Aligned Porosity: 1.079" in a 8.628" length of weldMax group length of Aligned Internal Porosity: 0.375"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 1.5"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.5"

Severe Cyclic:Max size of Random Internal Porosity: 0.156" Max Size of Isolated Internal Porosity: 0.240"Max sum of diameters of Aligned Porosity: 0.719" in a 8.628" length of weldMax group length of Aligned Internal Porosity: 0.250"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 1.0"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.0"

Page 249: NDT Code Book Made Easy

s

B31.38" s/160 - 0.906" Wall

PENETRAMETER SELECTIONNote: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Hole: 25 S/S Wire: 0.020 Esn. Wire: B3

F/S Hole: 20 F/S Wire: 0.016 Esn. Wire: B4Welds with reinforcement: S/S Hole: 30 S/S Wire: 0.025 Esn. Wire: B2

F/S Hole: 25 F/S Wire: 0.020 Esn. Wire: B3Maximum allowable reinforcement: 0.156" Total of wall + reinforcement: 1.062"CRACKS AND LACK OF FUSIONNone Allowed

INCOMPLETE PENETRATIONNormal ServiceGirth and Miter Groove, Branch Connections: Max 1.5" in a 6" length of weld.Longitudinal Groove: None allowed

Severe CyclicGirth and Miter Groove, Branch Connections, and Longitudinal Groove: None allowed

SLAG INCLUSION, TUNGSTEN INCLUSION, OR ELONGATED INDICATIONNormal ServiceMax Individual Length: 1.812" Max Individual Width: 0.125" Max Cumulative Length: 3.624" in 6" of weld

Severe Cyclic ConditionsMax Individual Length: 0.302" Max Individual Width: 0.094" Max Cumulative Length: 0.906" in 10.872"/w

UNDERCUTTINGNormal Services: Not a factor for normal service

Severe Cyclic: Zero allowed

CONCAVE ROOT SURFACE (SUCK-UP)Normal Service and Severe Cyclic: Unacceptable if concave root is darker than the wall

INTERNAL POROSITYRelevant Indication: 0.031

Normal Services:

Max Size of Random Internal Porosity: 0.234" Max Size of Isolated Internal Porosity: 0.375"Max Sum of diameters of Aligned Porosity: 1.359" in a 10.872" length of weldMax group length of Aligned Internal Porosity: 0.453"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 1.5"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.5"

Severe Cyclic:Max size of Random Internal Porosity: 0.156" Max Size of Isolated Internal Porosity: 0.250"Max sum of diameters of Aligned Porosity: 0.906" in a 10.872" length of weldMax group length of Aligned Internal Porosity: 0.302"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 1.0"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.0"

Page 250: NDT Code Book Made Easy

s

B31.38" XX Strong - 0.875" Wall

PENETRAMETER SELECTIONNote: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Hole: 25 S/S Wire: 0.020 Esn. Wire: B3

F/S Hole: 20 F/S Wire: 0.016 Esn. Wire: B4Welds with reinforcement: S/S Hole: 30 S/S Wire: 0.025 Esn. Wire: B2

F/S Hole: 25 F/S Wire: 0.020 Esn. Wire: B3Maximum allowable reinforcement: 0.156" Total of wall + reinforcement: 1.031"CRACKS AND LACK OF FUSIONNone Allowed

INCOMPLETE PENETRATIONNormal ServiceGirth and Miter Groove, Branch Connections: Max 1.5" in a 6" length of weld.Longitudinal Groove: None allowed

Severe CyclicGirth and Miter Groove, Branch Connections, and Longitudinal Groove: None allowed

SLAG INCLUSION, TUNGSTEN INCLUSION, OR ELONGATED INDICATIONNormal ServiceMax Individual Length: 1.750" Max Individual Width: 0.125" Max Cumulative Length: 3.500" in 6" of weld

Severe Cyclic ConditionsMax Individual Length: 0.292" Max Individual Width: 0.094" Max Cumulative Length: 0.875" in 10.500"/w

UNDERCUTTINGNormal Services: Not a factor for normal service

Severe Cyclic: Zero allowed

CONCAVE ROOT SURFACE (SUCK-UP)Normal Service and Severe Cyclic: Unacceptable if concave root is darker than the wall

INTERNAL POROSITYRelevant Indication: 0.031

Normal Services:

Max Size of Random Internal Porosity: 0.234" Max Size of Isolated Internal Porosity: 0.375"Max Sum of diameters of Aligned Porosity: 1.313" in a 10.5" length of weldMax group length of Aligned Internal Porosity: 0.438"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 1.5"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.5"

Severe Cyclic:Max size of Random Internal Porosity: 0.156" Max Size of Isolated Internal Porosity: 0.250"Max sum of diameters of Aligned Porosity: 0.875" in a 10.5" length of weldMax group length of Aligned Internal Porosity: 0.292"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 1.0"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.0"

Page 251: NDT Code Book Made Easy

s

B31.310" s/10 - 0.165" Wall

PENETRAMETER SELECTIONNote: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Hole: 12 S/S Wire: 0.008 Esn. Wire: A2

F/S Hole: 10 F/S Wire: 0.006 Esn. Wire: A3Welds with reinforcement: S/S Hole: 12 S/S Wire: 0.008 Esn. Wire: A2

F/S Hole: 10 F/S Wire: 0.006 Esn. Wire: A3Maximum allowable reinforcement: 0.0625" Total of wall + reinforcement: 0.228"CRACKS AND LACK OF FUSIONNone Allowed

INCOMPLETE PENETRATIONNormal ServiceGirth and Miter Groove, Branch Connections: Max 1.5" in a 6" length of weld.Longitudinal Groove: None allowed

Severe CyclicGirth and Miter Groove, Branch Connections, and Longitudinal Groove: None allowed

SLAG INCLUSION, TUNGSTEN INCLUSION, OR ELONGATED INDICATIONNormal ServiceMax Individual Length: 0.330" Max Individual Width: 0.083" Max Cumulative Length: 0.660" in 6" of weld

Severe Cyclic ConditionsMax Individual Length: 0.055" Max Individual Width: 0.055" Max Cumulative Length: 0.165" in 1.980" of w

UNDERCUTTINGNormal Services: Not a factor for normal service

Severe Cyclic: Zero allowed

CONCAVE ROOT SURFACE (SUCK-UP)Normal Service and Severe Cyclic: Unacceptable if concave root is darker than the wall

INTERNAL POROSITYRelevant Indication: 0.016

Normal Services:

Max Size of Random Internal Porosity: 0.041" Max Size of Isolated Internal Porosity: 0.055"Max Sum of diameters of Aligned Porosity: 0.165" in a 1.980" length of weldMax group length of Aligned Internal Porosity: 0.250"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 0.330"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.0"

Severe Cyclic:Max size of Random Internal Porosity: 0.041" Max Size of Isolated Internal Porosity: 0.055"Max sum of diameters of Aligned Porosity: 0.165" in a 1.980" length of weldMax group length of Aligned Internal Porosity: 0.250"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 0.330"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.0"

Page 252: NDT Code Book Made Easy

s

B31.310" s/40 & Std. - 0.365" Wall

PENETRAMETER SELECTIONNote: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Hole: 15 S/S Wire: 0.010 Esn. Wire: A1 or B6

F/S Hole: 12 F/S Wire: 0.008 Esn. Wire: A2Welds with reinforcement: S/S Hole: 17 S/S Wire: 0.013 Esn. Wire: B5

F/S Hole: 15 F/S Wire: 0.010 Esn. Wire: A1 or B6Maximum allowable reinforcement: 0.125" Total of wall + reinforcement: 0.490"CRACKS AND LACK OF FUSIONNone Allowed

INCOMPLETE PENETRATIONNormal ServiceGirth and Miter Groove, Branch Connections: Max 1.5" in a 6" length of weld.Longitudinal Groove: None allowed

Severe CyclicGirth and Miter Groove, Branch Connections, and Longitudinal Groove: None allowed

SLAG INCLUSION, TUNGSTEN INCLUSION, OR ELONGATED INDICATIONNormal ServiceMax Individual Length: 0.730" Max Individual Width: 0.125" Max Cumulative Length: 1.460" in 6" of weld

Severe Cyclic ConditionsMax Individual Length: 0.122" Max Individual Width: 0.094" Max Cumulative Length: 0.365" in 4.380" of w

UNDERCUTTINGNormal Services: Not a factor for normal service

Severe Cyclic: Zero allowed

CONCAVE ROOT SURFACE (SUCK-UP)Normal Service and Severe Cyclic: Unacceptable if concave root is darker than the wall

INTERNAL POROSITYRelevant Indication: 0.031

Normal Services:

Max Size of Random Internal Porosity: 0.137" Max Size of Isolated Internal Porosity: 0.183"Max Sum of diameters of Aligned Porosity: 0.548" in a 3.864" length of weldMax group length of Aligned Internal Porosity: 0.375"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 1.095"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.5"

Severe Cyclic:Max size of Random Internal Porosity: 0.091" Max Size of Isolated Internal Porosity: 0.122"Max sum of diameters of Aligned Porosity: 0.365" in a 4.380" length of weldMax group length of Aligned Internal Porosity: 0.250"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 0.730"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.0"

Page 253: NDT Code Book Made Easy

s

B31.310" s/80 - 0.594" Wall

PENETRAMETER SELECTIONNote: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Hole: 20 S/S Wire: 0.016 Esn. Wire: B4

F/S Hole: 17 F/S Wire: 0.013 Esn. Wire: B5Welds with reinforcement: S/S Hole: 20 S/S Wire: 0.016 Esn. Wire: B4

F/S Hole: 17 F/S Wire: 0.013 Esn. Wire: B5Maximum allowable reinforcement: 0.156" Total of wall + reinforcement: 0.750"CRACKS AND LACK OF FUSIONNone Allowed

INCOMPLETE PENETRATIONNormal ServiceGirth and Miter Groove, Branch Connections: Max 1.5" in a 6" length of weld.Longitudinal Groove: None allowed

Severe CyclicGirth and Miter Groove, Branch Connections, and Longitudinal Groove: None allowed

SLAG INCLUSION, TUNGSTEN INCLUSION, OR ELONGATED INDICATIONNormal ServiceMax Individual Length: 1.188" Max Individual Width: 0.125" Max Cumulative Length: 2.376" in 6" of weld

Severe Cyclic ConditionsMax Individual Length: 0.198" Max Individual Width: 0.094" Max Cumulative Length: 0.594" in 7.128" of w

UNDERCUTTINGNormal Services: Not a factor for normal service

Severe Cyclic: Zero allowed

CONCAVE ROOT SURFACE (SUCK-UP)Normal Service and Severe Cyclic: Unacceptable if concave root is darker than the wall

INTERNAL POROSITYRelevant Indication: 0.031

Normal Services:

Max Size of Random Internal Porosity: 0.223" Max Size of Isolated Internal Porosity: 0.297"Max Sum of diameters of Aligned Porosity: 0.894" in a 7.128" length of weldMax group length of Aligned Internal Porosity: 0.375"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 1.500"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.5"

Severe Cyclic:Max size of Random Internal Porosity: 0.149" Max Size of Isolated Internal Porosity: 0.198"Max sum of diameters of Aligned Porosity: 0.594" in a 7.128" length of weldMax group length of Aligned Internal Porosity: 0.250"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 1.000"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.0"

Page 254: NDT Code Book Made Easy

s

B31.310" Extra Strong - 0.500" Wall

PENETRAMETER SELECTIONNote: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Hole: 17 S/S Wire: 0.013 Esn. Wire: B5

F/S Hole: 15 F/S Wire: 0.010 Esn. Wire: A1 or B6Welds with reinforcement: S/S Hole: 20 S/S Wire: 0.016 Esn. Wire: B4

F/S Hole: 17 F/S Wire: 0.013 Esn. Wire: B5Maximum allowable reinforcement: 0.125" Total of wall + reinforcement: 0.625"CRACKS AND LACK OF FUSIONNone Allowed

INCOMPLETE PENETRATIONNormal ServiceGirth and Miter Groove, Branch Connections: Max 1.5" in a 6" length of weld.Longitudinal Groove: None allowed

Severe CyclicGirth and Miter Groove, Branch Connections, and Longitudinal Groove: None allowed

SLAG INCLUSION, TUNGSTEN INCLUSION, OR ELONGATED INDICATIONNormal ServiceMax Individual Length: 1.000" Max Individual Width: 0.125" Max Cumulative Length: 2.000" in 6" of weld

Severe Cyclic ConditionsMax Individual Length: 0.167" Max Individual Width: 0.094" Max Cumulative Length: 0.500" in 6.000"/w

UNDERCUTTINGNormal Services: Not a factor for normal service

Severe Cyclic: Zero allowed

CONCAVE ROOT SURFACE (SUCK-UP)Normal Service and Severe Cyclic: Unacceptable if concave root is darker than the wall

INTERNAL POROSITYRelevant Indication: 0.031

Normal Services:

Max Size of Random Internal Porosity: 0.188" Max Size of Isolated Internal Porosity: 0.250"Max Sum of diameters of Aligned Porosity: 0.750" in a 6.000" length of weldMax group length of Aligned Internal Porosity: 0.375"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 1.500"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.5"

Severe Cyclic:Max size of Random Internal Porosity: 0.125" Max Size of Isolated Internal Porosity: 0.167"Max sum of diameters of Aligned Porosity: 0.500" in a 6.000" length of weldMax group length of Aligned Internal Porosity: 0.250"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 1.000"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.0"

Page 255: NDT Code Book Made Easy

s

B31.310" s/120 - 0.844" Wall

PENETRAMETER SELECTIONNote: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Hole: 25 S/S Wire: 0.020 Esn. Wire: B3

F/S Hole: 20 F/S Wire: 0.016 Esn. Wire: B4Welds with reinforcement: S/S Hole: 25 S/S Wire: 0.020 Esn. Wire: B3

F/S Hole: 20 F/S Wire: 0.016 Esn. Wire: B4Maximum allowable reinforcement: 0.156" Total of wall + reinforcement: 1.000"CRACKS AND LACK OF FUSIONNone Allowed

INCOMPLETE PENETRATIONNormal ServiceGirth and Miter Groove, Branch Connections: Max 1.5" in a 6" length of weld.Longitudinal Groove: None allowed

Severe CyclicGirth and Miter Groove, Branch Connections, and Longitudinal Groove: None allowed

SLAG INCLUSION, TUNGSTEN INCLUSION, OR ELONGATED INDICATIONNormal ServiceMax Individual Length: 1.688" Max Individual Width: 0.125" Max Cumulative Length: 3.376" in 6" of weld

Severe Cyclic ConditionsMax Individual Length: 0.281" Max Individual Width: 0.094" Max Cumulative Length: 0.844" in 10.128"/w

UNDERCUTTINGNormal Services: Not a factor for normal service

Severe Cyclic: Zero allowed

CONCAVE ROOT SURFACE (SUCK-UP)Normal Service and Severe Cyclic: Unacceptable if concave root is darker than the wall

INTERNAL POROSITYRelevant Indication: 0.031

Normal Services:

Max Size of Random Internal Porosity: 0.234" Max Size of Isolated Internal Porosity: 0.375"Max Sum of diameters of Aligned Porosity: 1.266" in a 10.128" length of weldMax group length of Aligned Internal Porosity: 0.422"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 1.5"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.5"

Severe Cyclic:Max size of Random Internal Porosity: 0.156" Max Size of Isolated Internal Porosity: 0.250"Max sum of diameters of Aligned Porosity: 0.844" in a 10.128" length of weldMax group length of Aligned Internal Porosity: 0.281"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 1.0"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.0"

Page 256: NDT Code Book Made Easy

s

B31.310" s/160 - 1.125" Wall

PENETRAMETER SELECTIONNote: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Hole: 30 S/S Wire: 0.025 Esn. Wire: B2

F/S Hole: 25 F/S Wire: 0.020 Esn. Wire: B3Welds with reinforcement: S/S Hole: 30 S/S Wire: 0.025 Esn. Wire: B2

F/S Hole: 25 F/S Wire: 0.020 Esn. Wire: B3Maximum allowable reinforcement: 0.188" Total of wall + reinforcement: 1.313"CRACKS AND LACK OF FUSIONNone Allowed

INCOMPLETE PENETRATIONNormal ServiceGirth and Miter Groove, Branch Connections: Max 1.5" in a 6" length of weld.Longitudinal Groove: None allowed

Severe CyclicGirth and Miter Groove, Branch Connections, and Longitudinal Groove: None allowed

SLAG INCLUSION, TUNGSTEN INCLUSION, OR ELONGATED INDICATIONNormal ServiceMax Individual Length: 2.250" Max Individual Width: 0.125" Max Cumulative Length: 4.5" in 6" of weld

Severe Cyclic ConditionsMax Individual Length: 0.375" Max Individual Width: 0.094" Max Cumulative Length: 1.125" in 13.500"/w

UNDERCUTTINGNormal Services: Not a factor for normal service

Severe Cyclic: Zero allowed

CONCAVE ROOT SURFACE (SUCK-UP)Normal Service and Severe Cyclic: Unacceptable if concave root is darker than the wall

INTERNAL POROSITYRelevant Indication: 0.031

Normal Services:

Max Size of Random Internal Porosity: 0.234" Max Size of Isolated Internal Porosity: 0.375"Max Sum of diameters of Aligned Porosity: 1.688" in a 13.5" length of weldMax group length of Aligned Internal Porosity: 0.563"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 1.5"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.5"

Severe Cyclic:Max size of Random Internal Porosity: 0.156" Max Size of Isolated Internal Porosity: 0.250"Max sum of diameters of Aligned Porosity: 1.125" in a 13.5" length of weldMax group length of Aligned Internal Porosity: 0.375"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 1.0"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.0"

Page 257: NDT Code Book Made Easy

s

B31.310" XX Strong - 1.00" Wall

PENETRAMETER SELECTIONNote: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Hole: 25 S/S Wire: 0.020 Esn. Wire: B3

F/S Hole: 20 F/S Wire: 0.016 Esn. Wire: B4Welds with reinforcement: S/S Hole: 30 S/S Wire: 0.025 Esn. Wire: B2

F/S Hole: 25 F/S Wire: 0.020 Esn. Wire: B3Maximum allowable reinforcement: 0.156" Total of wall + reinforcement: 1.156"CRACKS AND LACK OF FUSIONNone Allowed

INCOMPLETE PENETRATIONNormal ServiceGirth and Miter Groove, Branch Connections: Max 1.5" in a 6" length of weld.Longitudinal Groove: None allowed

Severe CyclicGirth and Miter Groove, Branch Connections, and Longitudinal Groove: None allowed

SLAG INCLUSION, TUNGSTEN INCLUSION, OR ELONGATED INDICATIONNormal ServiceMax Individual Length: 2.000" Max Individual Width: 0.125" Max Cumulative Length: 4.000" in 6" of weld

Severe Cyclic ConditionsMax Individual Length: 0.333" Max Individual Width: 0.094" Max Cumulative Length: 1.000" in 12.00"/w

UNDERCUTTINGNormal Services: Not a factor for normal service

Severe Cyclic: Zero allowed

CONCAVE ROOT SURFACE (SUCK-UP)Normal Service and Severe Cyclic: Unacceptable if concave root is darker than the wall

INTERNAL POROSITYRelevant Indication: 0.031

Normal Services:

Max Size of Random Internal Porosity: 0.234" Max Size of Isolated Internal Porosity: 0.375"Max Sum of diameters of Aligned Porosity: 1.500" in a 12.0" length of weldMax group length of Aligned Internal Porosity: 0.500"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 1.5"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.5"

Severe Cyclic:Max size of Random Internal Porosity: 0.156" Max Size of Isolated Internal Porosity: 0.250"Max sum of diameters of Aligned Porosity: 1.000" in a 12.0" length of weldMax group length of Aligned Internal Porosity: 0.333"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 1.0"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.0"

Page 258: NDT Code Book Made Easy

s

B31.312" s/10 - 0.180" Wall

PENETRAMETER SELECTIONNote: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Hole: 12 S/S Wire: 0.008 Esn. Wire: A2

F/S Hole: 10 F/S Wire: 0.006 Esn. Wire: A3Welds with reinforcement: S/S Hole: 12 S/S Wire: 0.008 Esn. Wire: A2

F/S Hole: 10 F/S Wire: 0.006 Esn. Wire: A3Maximum allowable reinforcement: 0.0625" Total of wall + reinforcement: 0.243"CRACKS AND LACK OF FUSIONNone Allowed

INCOMPLETE PENETRATIONNormal ServiceGirth and Miter Groove, Branch Connections: Max 1.5" in a 6" length of weld.Longitudinal Groove: None allowed

Severe CyclicGirth and Miter Groove, Branch Connections, and Longitudinal Groove: None allowed

SLAG INCLUSION, TUNGSTEN INCLUSION, OR ELONGATED INDICATIONNormal ServiceMax Individual Length: 0.360" Max Individual Width: 0.090" Max Cumulative Length: 0.720" in 6" of weld

Severe Cyclic ConditionsMax Individual Length: 0.060" Max Individual Width: 0.060" Max Cumulative Length: 0.180" in 2.160" of w

UNDERCUTTINGNormal Services: Not a factor for normal service

Severe Cyclic: Zero allowed

CONCAVE ROOT SURFACE (SUCK-UP)Normal Service and Severe Cyclic: Unacceptable if concave root is darker than the wall

INTERNAL POROSITY0.016

Normal Services:

Max Size of Random Internal Porosity: 0.045" Max Size of Isolated Internal Porosity: 0.060"Max Sum of diameters of Aligned Porosity: 0.180" in a 2.160" length of weldMax group length of Aligned Internal Porosity: 0.250"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 0.360"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.0"

Severe Cyclic:Max size of Random Internal Porosity: 0.045" Max Size of Isolated Internal Porosity: 0.060"Max sum of diameters of Aligned Porosity: 0.180" in a 2.160" length of weldMax group length of Aligned Internal Porosity: 0.250"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 0.360"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.0"

Page 259: NDT Code Book Made Easy

s

B31.312" Standard - 0.375" Wall

PENETRAMETER SELECTIONNote: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Hole: 15 S/S Wire: 0.010 Esn. Wire: A1 or B6

F/S Hole: 12 F/S Wire: 0.008 Esn. Wire: A2Welds with reinforcement: S/S Hole: 17 S/S Wire: 0.013 Esn. Wire: B5

F/S Hole: 15 F/S Wire: 0.010 Esn. Wire: A1 or B6Maximum allowable reinforcement: 0.125" Total of wall + reinforcement: 0.500"CRACKS AND LACK OF FUSIONNone Allowed

INCOMPLETE PENETRATIONNormal ServiceGirth and Miter Groove, Branch Connections: Max 1.5" in a 6" length of weld.Longitudinal Groove: None allowed

Severe CyclicGirth and Miter Groove, Branch Connections, and Longitudinal Groove: None allowed

SLAG INCLUSION, TUNGSTEN INCLUSION, OR ELONGATED INDICATIONNormal ServiceMax Individual Length: 0.750" Max Individual Width: 0.125" Max Cumulative Length: 1.500" in 6" of weld

Severe Cyclic ConditionsMax Individual Length: 0.125" Max Individual Width: 0.094" Max Cumulative Length: 0.375" in 4.5" of w

UNDERCUTTINGNormal Services: Not a factor for normal service

Severe Cyclic: Zero allowed

CONCAVE ROOT SURFACE (SUCK-UP)Normal Service and Severe Cyclic: Unacceptable if concave root is darker than the wall

INTERNAL POROSITYRelevant Indication: 0.031

Normal Services:

Max Size of Random Internal Porosity: 0.141" Max Size of Isolated Internal Porosity: 0.188"Max Sum of diameters of Aligned Porosity: 0.563" in a 4.5" length of weldMax group length of Aligned Internal Porosity: 0.375"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 1.125"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.5"

Severe Cyclic:Max size of Random Internal Porosity: 0.094" Max Size of Isolated Internal Porosity: 0.125"Max sum of diameters of Aligned Porosity: 0.375" in a 4.5" length of weldMax group length of Aligned Internal Porosity: 0.250"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 0.750"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.0"

Page 260: NDT Code Book Made Easy

s

B31.312" s/40 - 0.406" Wall

PENETRAMETER SELECTIONNote: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Hole: 17 S/S Wire: 0.013 Esn. Wire: B5

F/S Hole: 15 F/S Wire: 0.010 Esn. Wire: A1 or B6Welds with reinforcement: S/S Hole: 20 S/S Wire: 0.016 Esn. Wire: B4

F/S Hole: 17 F/S Wire: 0.013 Esn. Wire: B5Maximum allowable reinforcement: 0.125" Total of wall + reinforcement: 0.531"CRACKS AND LACK OF FUSIONNone Allowed

INCOMPLETE PENETRATIONNormal ServiceGirth and Miter Groove, Branch Connections: Max 1.5" in a 6" length of weld.Longitudinal Groove: None allowed

Severe CyclicGirth and Miter Groove, Branch Connections, and Longitudinal Groove: None allowed

SLAG INCLUSION, TUNGSTEN INCLUSION, OR ELONGATED INDICATIONNormal ServiceMax Individual Length: 0.812" Max Individual Width: 0.125" Max Cumulative Length: 1.624" in 6" of weld

Severe Cyclic ConditionsMax Individual Length: 0.135" Max Individual Width: 0.094" Max Cumulative Length: 0.406" in 4.872"/w

UNDERCUTTINGNormal Services: Not a factor for normal service

Severe Cyclic: Zero allowed

CONCAVE ROOT SURFACE (SUCK-UP)Normal Service and Severe Cyclic: Unacceptable if concave root is darker than the wall

INTERNAL POROSITYRelevant Indication: 0.031

Normal Services:

Max Size of Random Internal Porosity: 0.152" Max Size of Isolated Internal Porosity: 0.203"Max Sum of diameters of Aligned Porosity: 0.609" in a 4.872" length of weldMax group length of Aligned Internal Porosity: 0.375"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 1.218"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.5"

Severe Cyclic:Max size of Random Internal Porosity: 0.102" Max Size of Isolated Internal Porosity: 0.135"Max sum of diameters of Aligned Porosity: 0.406" in a 4.872" length of weldMax group length of Aligned Internal Porosity: 0.250"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 0.812"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.0"

Page 261: NDT Code Book Made Easy

s

B31.312" s/80 - 0.688" Wall

PENETRAMETER SELECTIONNote: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Hole: 20 S/S Wire: 0.016 Esn. Wire: B4

F/S Hole: 17 F/S Wire: 0.013 Esn. Wire: B5Welds with reinforcement: S/S Hole: 25 S/S Wire: 0.020 Esn. Wire: B3

F/S Hole: 20 F/S Wire: 0.016 Esn. Wire: B4Maximum allowable reinforcement: 0.156" Total of wall + reinforcement: 0.844"CRACKS AND LACK OF FUSIONNone Allowed

INCOMPLETE PENETRATIONNormal ServiceGirth and Miter Groove, Branch Connections: Max 1.5" in a 6" length of weld.Longitudinal Groove: None allowed

Severe CyclicGirth and Miter Groove, Branch Connections, and Longitudinal Groove: None allowed

SLAG INCLUSION, TUNGSTEN INCLUSION, OR ELONGATED INDICATIONNormal ServiceMax Individual Length: 1.376" Max Individual Width: 0.125" Max Cumulative Length: 2.752" in 6" of weld

Severe Cyclic ConditionsMax Individual Length: 0.229" Max Individual Width: 0.094" Max Cumulative Length: 0.688" in 8.256" of w

UNDERCUTTINGNormal Services: Not a factor for normal service

Severe Cyclic: Zero allowed

CONCAVE ROOT SURFACE (SUCK-UP)Normal Service and Severe Cyclic: Unacceptable if concave root is darker than the wall

INTERNAL POROSITYRelevant Indication: 0.031

Normal Services:

Max Size of Random Internal Porosity: 0.234" Max Size of Isolated Internal Porosity: 0.344"Max Sum of diameters of Aligned Porosity: 1.032" in a 8.256" length of weldMax group length of Aligned Internal Porosity: 0.375"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 1.500"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.5"

Severe Cyclic:Max size of Random Internal Porosity: 0.156" Max Size of Isolated Internal Porosity: 0.229"Max sum of diameters of Aligned Porosity: 0.688" in a 8.256" length of weldMax group length of Aligned Internal Porosity: 0.250"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 1.000"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.0"

Page 262: NDT Code Book Made Easy

s

B31.312" Extra Strong - 0.500" Wall

PENETRAMETER SELECTIONNote: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Hole: 17 S/S Wire: 0.013 Esn. Wire: B5

F/S Hole: 15 F/S Wire: 0.010 Esn. Wire: A1 or B6Welds with reinforcement: S/S Hole: 20 S/S Wire: 0.016 Esn. Wire: B4

F/S Hole: 17 F/S Wire: 0.013 Esn. Wire: B5Maximum allowable reinforcement: 0.125" Total of wall + reinforcement: 0.625"CRACKS AND LACK OF FUSIONNone Allowed

INCOMPLETE PENETRATIONNormal ServiceGirth and Miter Groove, Branch Connections: Max 1.5" in a 6" length of weld.Longitudinal Groove: None allowed

Severe CyclicGirth and Miter Groove, Branch Connections, and Longitudinal Groove: None allowed

SLAG INCLUSION, TUNGSTEN INCLUSION, OR ELONGATED INDICATIONNormal ServiceMax Individual Length: 1.000" Max Individual Width: 0.125" Max Cumulative Length: 2.000" in 6" of weld

Severe Cyclic ConditionsMax Individual Length: 0.167" Max Individual Width: 0.094" Max Cumulative Length: 0.500" in 6.0" of w

UNDERCUTTINGNormal Services: Not a factor for normal service

Severe Cyclic: Zero allowed

CONCAVE ROOT SURFACE (SUCK-UP)Normal Service and Severe Cyclic: Unacceptable if concave root is darker than the wall

INTERNAL POROSITYRelevant Indication: 0.031

Normal Services:

Max Size of Random Internal Porosity: 0.188" Max Size of Isolated Internal Porosity: 0.250"Max Sum of diameters of Aligned Porosity: 0.750" in a 6.000" length of weldMax group length of Aligned Internal Porosity: 0.375"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 1.500"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.5"

Severe Cyclic:Max size of Random Internal Porosity: 0.125" Max Size of Isolated Internal Porosity: 0.167"Max sum of diameters of Aligned Porosity: 0.500" in a 6.000" length of weldMax group length of Aligned Internal Porosity: 0.250"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 1.000"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.0"

Page 263: NDT Code Book Made Easy

s

B31.312" XX Strong - 1.00" Wall

PENETRAMETER SELECTIONNote: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Hole: 25 S/S Wire: 0.020 Esn. Wire: B3

F/S Hole: 20 F/S Wire: 0.016 Esn. Wire: B4Welds with reinforcement: S/S Hole: 30 S/S Wire: 0.025 Esn. Wire: B2

F/S Hole: 25 F/S Wire: 0.020 Esn. Wire: B3Maximum allowable reinforcement: 0.156" Total of wall + reinforcement: 1.156"CRACKS AND LACK OF FUSIONNone Allowed

INCOMPLETE PENETRATIONNormal ServiceGirth and Miter Groove, Branch Connections: Max 1.5" in a 6" length of weld.Longitudinal Groove: None allowed

Severe CyclicGirth and Miter Groove, Branch Connections, and Longitudinal Groove: None allowed

SLAG INCLUSION, TUNGSTEN INCLUSION, OR ELONGATED INDICATIONNormal ServiceMax Individual Length: 2.000" Max Individual Width: 0.125" Max Cumulative Length: 4.000" in 6" of weld

Severe Cyclic ConditionsMax Individual Length: 0.333" Max Individual Width: 0.094" Max Cumulative Length: 1.000" in 12.00"/w

UNDERCUTTINGNormal Services: Not a factor for normal service

Severe Cyclic: Zero allowed

CONCAVE ROOT SURFACE (SUCK-UP)Normal Service and Severe Cyclic: Unacceptable if concave root is darker than the wall

INTERNAL POROSITYRelevant Indication: 0.031

Normal Services:

Max Size of Random Internal Porosity: 0.234" Max Size of Isolated Internal Porosity: 0.375"Max Sum of diameters of Aligned Porosity: 1.500" in a 12.0" length of weldMax group length of Aligned Internal Porosity: 0.500"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 1.5"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.5"

Severe Cyclic:Max size of Random Internal Porosity: 0.156" Max Size of Isolated Internal Porosity: 0.250"Max sum of diameters of Aligned Porosity: 1.000" in a 12.0" length of weldMax group length of Aligned Internal Porosity: 0.333"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 1.0"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.0"

Page 264: NDT Code Book Made Easy

s

B31.312" s/120 - 1.00" Wall

PENETRAMETER SELECTIONNote: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Hole: 25 S/S Wire: 0.020 Esn. Wire: B3

F/S Hole: 20 F/S Wire: 0.016 Esn. Wire: B4Welds with reinforcement: S/S Hole: 30 S/S Wire: 0.025 Esn. Wire: B2

F/S Hole: 25 F/S Wire: 0.020 Esn. Wire: B3Maximum allowable reinforcement: 0.156" Total of wall + reinforcement: 1.156"CRACKS AND LACK OF FUSIONNone Allowed

INCOMPLETE PENETRATIONNormal ServiceGirth and Miter Groove, Branch Connections: Max 1.5" in a 6" length of weld.Longitudinal Groove: None allowed

Severe CyclicGirth and Miter Groove, Branch Connections, and Longitudinal Groove: None allowed

SLAG INCLUSION, TUNGSTEN INCLUSION, OR ELONGATED INDICATIONNormal ServiceMax Individual Length: 2.000" Max Individual Width: 0.125" Max Cumulative Length: 4.000" in 6" of weld

Severe Cyclic ConditionsMax Individual Length: 0.333" Max Individual Width: 0.094" Max Cumulative Length: 1.000" in 12.00"/w

UNDERCUTTINGNormal Services: Not a factor for normal service

Severe Cyclic: Zero allowed

CONCAVE ROOT SURFACE (SUCK-UP)Normal Service and Severe Cyclic: Unacceptable if concave root is darker than the wall

INTERNAL POROSITYRelevant Indication: 0.031

Normal Services:

Max Size of Random Internal Porosity: 0.234" Max Size of Isolated Internal Porosity: 0.375"Max Sum of diameters of Aligned Porosity: 1.500" in a 12.0" length of weldMax group length of Aligned Internal Porosity: 0.500"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 1.5"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.5"

Severe Cyclic:Max size of Random Internal Porosity: 0.156" Max Size of Isolated Internal Porosity: 0.250"Max sum of diameters of Aligned Porosity: 1.000" in a 12.0" length of weldMax group length of Aligned Internal Porosity: 0.333"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 1.0"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.0"

Page 265: NDT Code Book Made Easy

s

B31.312" s/160 - 1.312" Wall

PENETRAMETER SELECTIONNote: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Hole: 30 S/S Wire: 0.025 Esn. Wire: B2

F/S Hole: 25 F/S Wire: 0.020 Esn. Wire: B3Welds with reinforcement: S/S Hole: 30 S/S Wire: 0.025 Esn. Wire: B2

F/S Hole: 25 F/S Wire: 0.020 Esn. Wire: B3Maximum allowable reinforcement: 0.188" Total of wall + reinforcement: 1.500"CRACKS AND LACK OF FUSIONNone Allowed

INCOMPLETE PENETRATIONNormal ServiceGirth and Miter Groove, Branch Connections: Max 1.5" in a 6" length of weld.Longitudinal Groove: None allowed

Severe CyclicGirth and Miter Groove, Branch Connections, and Longitudinal Groove: None allowed

SLAG INCLUSION, TUNGSTEN INCLUSION, OR ELONGATED INDICATIONNormal ServiceMax Individual Length: 2.624" Max Individual Width: 0.125" Max Cumulative Length: 5.248" in 6" of weld

Severe Cyclic ConditionsMax Individual Length: 0.437" Max Individual Width: 0.094" Max Cumulative Length: 1.312" in 15.744"/w

UNDERCUTTINGNormal Services: Not a factor for normal service

Severe Cyclic: Zero allowed

CONCAVE ROOT SURFACE (SUCK-UP)Normal Service and Severe Cyclic: Unacceptable if concave root is darker than the wall

INTERNAL POROSITYRelevant Indication: 0.031

Normal Services:

Max Size of Random Internal Porosity: 0.234" Max Size of Isolated Internal Porosity: 0.375"Max Sum of diameters of Aligned Porosity: 1.968" in a 15.744" length of weldMax group length of Aligned Internal Porosity: 0.656"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 1.5"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.5"

Severe Cyclic:Max size of Random Internal Porosity: 0.156" Max Size of Isolated Internal Porosity: 0.250"Max sum of diameters of Aligned Porosity: 1.312" in a 15.744" length of weldMax group length of Aligned Internal Porosity: 0.437"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 1.0"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.0"

Page 266: NDT Code Book Made Easy

s

B31.316" s/10 - 0.188" Wall

PENETRAMETER SELECTIONNote: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Hole: 12 S/S Wire: 0.008 Esn. Wire: A2

F/S Hole: 10 F/S Wire: 0.006 Esn. Wire: A3Welds with reinforcement: S/S Hole: 15 S/S Wire: 0.010 Esn. Wire: A1 or B6

F/S Hole: 12 F/S Wire: 0.008 Esn. Wire: A2Maximum allowable reinforcement: 0.0625" Total of wall + reinforcement: 0.251"CRACKS AND LACK OF FUSIONNone Allowed

INCOMPLETE PENETRATIONNormal ServiceGirth and Miter Groove, Branch Connections: Max 1.5" in a 6" length of weld.Longitudinal Groove: None allowed

Severe CyclicGirth and Miter Groove, Branch Connections, and Longitudinal Groove: None allowed

SLAG INCLUSION, TUNGSTEN INCLUSION, OR ELONGATED INDICATIONNormal ServiceMax Individual Length: 0.376" Max Individual Width: 0.094" Max Cumulative Length: 0.752" in 6" of weld

Severe Cyclic ConditionsMax Individual Length: 0.063" Max Individual Width: 0.063" Max Cumulative Length: 0.188" in 2.256" of w

UNDERCUTTINGNormal Services: Not a factor for normal service

Severe Cyclic: Zero allowed

CONCAVE ROOT SURFACE (SUCK-UP)Normal Service and Severe Cyclic: Unacceptable if concave root is darker than the wall

INTERNAL POROSITYRelevant Indication: 0.016

Normal Services:

Max Size of Random Internal Porosity: 0.047" Max Size of Isolated Internal Porosity: 0.063"Max Sum of diameters of Aligned Porosity: 0.188" in a 2.256" length of weldMax group length of Aligned Internal Porosity: 0.250"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 0.376"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.0"

Severe Cyclic:Max size of Random Internal Porosity: 0.047" Max Size of Isolated Internal Porosity: 0.063"Max sum of diameters of Aligned Porosity: 0.188" in a 2.256" length of weldMax group length of Aligned Internal Porosity: 0.250"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 0.376"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.0"

Page 267: NDT Code Book Made Easy

s

B31.316 " Standard - 0.375" Wall

PENETRAMETER SELECTIONNote: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Hole: 15 S/S Wire: 0.010 Esn. Wire: A1 or B6

F/S Hole: 12 F/S Wire: 0.008 Esn. Wire: A2Welds with reinforcement: S/S Hole: 17 S/S Wire: 0.013 Esn. Wire: B5

F/S Hole: 15 F/S Wire: 0.010 Esn. Wire: A1 or B6Maximum allowable reinforcement: 0.125" Total of wall + reinforcement: 0.500"CRACKS AND LACK OF FUSIONNone Allowed

INCOMPLETE PENETRATIONNormal ServiceGirth and Miter Groove, Branch Connections: Max 1.5" in a 6" length of weld.Longitudinal Groove: None allowed

Severe CyclicGirth and Miter Groove, Branch Connections, and Longitudinal Groove: None allowed

SLAG INCLUSION, TUNGSTEN INCLUSION, OR ELONGATED INDICATIONNormal ServiceMax Individual Length: 0.750" Max Individual Width: 0.125" Max Cumulative Length: 1.500" in 6" of weld

Severe Cyclic ConditionsMax Individual Length: 0.125" Max Individual Width: 0.094" Max Cumulative Length: 0.375" in 4.500"/w

UNDERCUTTINGNormal Services: Not a factor for normal service

Severe Cyclic: Zero allowed

CONCAVE ROOT SURFACE (SUCK-UP)Normal Service and Severe Cyclic: Unacceptable if concave root is darker than the wall

INTERNAL POROSITYRelevant Indication: 0.031

Normal Services:

Max Size of Random Internal Porosity: 0.141" Max Size of Isolated Internal Porosity: 0.188"Max Sum of diameters of Aligned Porosity: 0.563" in a 4.500" length of weldMax group length of Aligned Internal Porosity: 0.375"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 1.125"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.5"

Severe Cyclic:Max size of Random Internal Porosity: 0.094" Max Size of Isolated Internal Porosity: 0.125"Max sum of diameters of Aligned Porosity: 0.375" in a 4.500" length of weldMax group length of Aligned Internal Porosity: 0.250"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 0.750"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.0"

Page 268: NDT Code Book Made Easy

s

B31.316" s/40 - 0.500" Wall

PENETRAMETER SELECTIONNote: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Hole: 17 S/S Wire: 0.013 Esn. Wire: B5

F/S Hole: 15 F/S Wire: 0.010 Esn. Wire: A1 or B6Welds with reinforcement: S/S Hole: 20 S/S Wire: 0.016 Esn. Wire: B4

F/S Hole: 17 F/S Wire: 0.013 Esn. Wire: B5Maximum allowable reinforcement: 0.125" Total of wall + reinforcement: 0.625"CRACKS AND LACK OF FUSIONNone Allowed

INCOMPLETE PENETRATIONNormal ServiceGirth and Miter Groove, Branch Connections: Max 1.5" in a 6" length of weld.Longitudinal Groove: None allowed

Severe CyclicGirth and Miter Groove, Branch Connections, and Longitudinal Groove: None allowed

SLAG INCLUSION, TUNGSTEN INCLUSION, OR ELONGATED INDICATIONNormal ServiceMax Individual Length: 1.000" Max Individual Width: 0.125" Max Cumulative Length: 2.000" in 6" of weld

Severe Cyclic ConditionsMax Individual Length: 0.167" Max Individual Width: 0.094" Max Cumulative Length: 0.500" in 6.0" of w

UNDERCUTTINGNormal Services: Not a factor for normal service

Severe Cyclic: Zero allowed

CONCAVE ROOT SURFACE (SUCK-UP)Normal Service and Severe Cyclic: Unacceptable if concave root is darker than the wall

INTERNAL POROSITYRelevant Indication: 0.031

Normal Services:

Max Size of Random Internal Porosity: 0.188" Max Size of Isolated Internal Porosity: 0.250"Max Sum of diameters of Aligned Porosity: 0.750" in a 6.000" length of weldMax group length of Aligned Internal Porosity: 0.375"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 1.500"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.5"

Severe Cyclic:Max size of Random Internal Porosity: 0.125" Max Size of Isolated Internal Porosity: 0.167"Max sum of diameters of Aligned Porosity: 0.500" in a 6.000" length of weldMax group length of Aligned Internal Porosity: 0.250"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 1.000"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.0"

Page 269: NDT Code Book Made Easy

s

B31.316" Extra Strong - 0.500" Wall

PENETRAMETER SELECTIONNote: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Hole: 17 S/S Wire: 0.013 Esn. Wire: B5

F/S Hole: 15 F/S Wire: 0.010 Esn. Wire: A1 or B6Welds with reinforcement: S/S Hole: 20 S/S Wire: 0.016 Esn. Wire: B4

F/S Hole: 17 F/S Wire: 0.013 Esn. Wire: B5Maximum allowable reinforcement: 0.125" Total of wall + reinforcement: 0.625"CRACKS AND LACK OF FUSIONNone Allowed

INCOMPLETE PENETRATIONNormal ServiceGirth and Miter Groove, Branch Connections: Max 1.5" in a 6" length of weld.Longitudinal Groove: None allowed

Severe CyclicGirth and Miter Groove, Branch Connections, and Longitudinal Groove: None allowed

SLAG INCLUSION, TUNGSTEN INCLUSION, OR ELONGATED INDICATIONNormal ServiceMax Individual Length: 1.000" Max Individual Width: 0.125" Max Cumulative Length: 2.000" in 6" of weld

Severe Cyclic ConditionsMax Individual Length: 0.167" Max Individual Width: 0.094" Max Cumulative Length: 0.500" in 6.0" of w

UNDERCUTTINGNormal Services: Not a factor for normal service

Severe Cyclic: Zero allowed

CONCAVE ROOT SURFACE (SUCK-UP)Normal Service and Severe Cyclic: Unacceptable if concave root is darker than the wall

INTERNAL POROSITYRelevant Indication: 0.031

Normal Services:

Max Size of Random Internal Porosity: 0.188" Max Size of Isolated Internal Porosity: 0.250"Max Sum of diameters of Aligned Porosity: 0.750" in a 6.000" length of weldMax group length of Aligned Internal Porosity: 0.375"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 1.500"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.5"

Severe Cyclic:Max size of Random Internal Porosity: 0.125" Max Size of Isolated Internal Porosity: 0.167"Max sum of diameters of Aligned Porosity: 0.500" in a 6.000" length of weldMax group length of Aligned Internal Porosity: 0.250"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 1.000"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.0"

Page 270: NDT Code Book Made Easy

s

B31.316" s/80 - 0.844" Wall

PENETRAMETER SELECTIONNote: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Hole: 25 S/S Wire: 0.020 Esn. Wire: B3

F/S Hole: 20 F/S Wire: 0.016 Esn. Wire: B4Welds with reinforcement: S/S Hole: 25 S/S Wire: 0.020 Esn. Wire: B3

F/S Hole: 20 F/S Wire: 0.016 Esn. Wire: B4Maximum allowable reinforcement: 0.156" Total of wall + reinforcement: 1.00"CRACKS AND LACK OF FUSIONNone Allowed

INCOMPLETE PENETRATIONNormal ServiceGirth and Miter Groove, Branch Connections: Max 1.5" in a 6" length of weld.Longitudinal Groove: None allowed

Severe CyclicGirth and Miter Groove, Branch Connections, and Longitudinal Groove: None allowed

SLAG INCLUSION, TUNGSTEN INCLUSION, OR ELONGATED INDICATIONNormal ServiceMax Individual Length: 1.688" Max Individual Width: 0.125" Max Cumulative Length: 3.376" in 6" of weld

Severe Cyclic ConditionsMax Individual Length: 0.281" Max Individual Width: 0.094" Max Cumulative Length: 0.844" in 10.128"/w

UNDERCUTTINGNormal Services: Not a factor for normal service

Severe Cyclic: Zero allowed

CONCAVE ROOT SURFACE (SUCK-UP)Normal Service and Severe Cyclic: Unacceptable if concave root is darker than the wall

INTERNAL POROSITYRelevant Indication: 0.031

Normal Services:

Max Size of Random Internal Porosity: 0.234" Max Size of Isolated Internal Porosity: 0.375"Max Sum of diameters of Aligned Porosity: 1.266" in a 10.128" length of weldMax group length of Aligned Internal Porosity: 0.422"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 1.500"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.5"

Severe Cyclic:Max size of Random Internal Porosity: 0.156" Max Size of Isolated Internal Porosity: 0.250"Max sum of diameters of Aligned Porosity: 0.844" in a 10.128" length of weldMax group length of Aligned Internal Porosity: 0.281"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 1.000"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.0"

Page 271: NDT Code Book Made Easy

s

B31.316" s/120 - 1.219" Wall

PENETRAMETER SELECTIONNote: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Hole: 30 S/S Wire: 0.025 Esn. Wire: B2

F/S Hole: 25 F/S Wire: 0.020 Esn. Wire: B3Welds with reinforcement: S/S Hole: 30 S/S Wire: 0.025 Esn. Wire: B2

F/S Hole: 25 F/S Wire: 0.020 Esn. Wire: B3Maximum allowable reinforcement: 0.188" Total of wall + reinforcement: 1.407"CRACKS AND LACK OF FUSIONNone Allowed

INCOMPLETE PENETRATIONNormal ServiceGirth and Miter Groove, Branch Connections: Max 1.5" in a 6" length of weld.Longitudinal Groove: None allowed

Severe CyclicGirth and Miter Groove, Branch Connections, and Longitudinal Groove: None allowed

SLAG INCLUSION, TUNGSTEN INCLUSION, OR ELONGATED INDICATIONNormal ServiceMax Individual Length: 2.438" Max Individual Width: 0.125" Max Cumulative Length: 4.876" in 6" of weld

Severe Cyclic ConditionsMax Individual Length: 0.406" Max Individual Width: 0.094" Max Cumulative Length: 1.219" in 14.628"/w

UNDERCUTTINGNormal Services: Not a factor for normal service

Severe Cyclic: Zero allowed

CONCAVE ROOT SURFACE (SUCK-UP)Normal Service and Severe Cyclic: Unacceptable if concave root is darker than the wall

INTERNAL POROSITYRelevant Indication: 0.031

Normal Services:

Max Size of Random Internal Porosity: 0.234" Max Size of Isolated Internal Porosity: 0.375"Max Sum of diameters of Aligned Porosity: 1.829" in a 14.628" length of weldMax group length of Aligned Internal Porosity: 0.610"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 1.500"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.5"

Severe Cyclic:Max size of Random Internal Porosity: 0.156" Max Size of Isolated Internal Porosity: 0.250"Max sum of diameters of Aligned Porosity: 1.219" in a 14.628" length of weldMax group length of Aligned Internal Porosity: 0.406"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 1.000"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.0"

Page 272: NDT Code Book Made Easy

s

B31.316" s/160 - 1.594" Wall

PENETRAMETER SELECTIONNote: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Hole: 35 S/S Wire: 0.032 Esn. Wire: B1 or C6

F/S Hole: 30 F/S Wire: 0.025 Esn. Wire: B2Welds with reinforcement: S/S Hole: 35 S/S Wire: 0.032 Esn. Wire: B1 or C6

F/S Hole: 30 F/S Wire: 0.025 Esn. Wire: B2Maximum allowable reinforcement: 0.188" Total of wall + reinforcement: 1.782"CRACKS AND LACK OF FUSIONNone Allowed

INCOMPLETE PENETRATIONNormal ServiceGirth and Miter Groove, Branch Connections: Max 1.5" in a 6" length of weld.Longitudinal Groove: None allowed

Severe CyclicGirth and Miter Groove, Branch Connections, and Longitudinal Groove: None allowed

SLAG INCLUSION, TUNGSTEN INCLUSION, OR ELONGATED INDICATIONNormal ServiceMax Individual Length: 3.188" Max Individual Width: 0.125" Max Cumulative Length: 6.376" in 6" of weld

Severe Cyclic ConditionsMax Individual Length: 0.531" Max Individual Width: 0.094" Max Cumulative Length: 1.594" in 19.128"/w

UNDERCUTTINGNormal Services: Not a factor for normal service

Severe Cyclic: Zero allowed

CONCAVE ROOT SURFACE (SUCK-UP)Normal Service and Severe Cyclic: Unacceptable if concave root is darker than the wall

INTERNAL POROSITYRelevant Indication: 0.031

Normal Services:

Max Size of Random Internal Porosity: 0.234" Max Size of Isolated Internal Porosity: 0.375"Max Sum of diameters of Aligned Porosity: 2.391" in a 19.128" length of weldMax group length of Aligned Internal Porosity: 0.797"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 1.500"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.5"

Severe Cyclic:Max size of Random Internal Porosity: 0.156" Max Size of Isolated Internal Porosity: 0.250"Max sum of diameters of Aligned Porosity: 1.594" in a 19.128" length of weldMax group length of Aligned Internal Porosity: 0.531"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 1.000"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.0"

Page 273: NDT Code Book Made Easy

s

B31.320" s/10 - 0.218" Wall

PENETRAMETER SELECTIONNote: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Hole: 12 S/S Wire: 0.008 Esn. Wire: A2

F/S Hole: 10 F/S Wire: 0.006 Esn. Wire: A3Welds with reinforcement: S/S Hole: 15 S/S Wire: 0.010 Esn. Wire: A1 or B6

F/S Hole: 12 F/S Wire: 0.008 Esn. Wire: A2Maximum allowable reinforcement: 0.0625" Total of wall + reinforcement: 0.281"CRACKS AND LACK OF FUSIONNone Allowed

INCOMPLETE PENETRATIONNormal ServiceGirth and Miter Groove, Branch Connections: Max 1.5" in a 6" length of weld.Longitudinal Groove: None allowed

Severe CyclicGirth and Miter Groove, Branch Connections, and Longitudinal Groove: None allowed

SLAG INCLUSION, TUNGSTEN INCLUSION, OR ELONGATED INDICATIONNormal ServiceMax Individual Length: 0.436" Max Individual Width: 0.109" Max Cumulative Length: 0.872" in 6" of weld

Severe Cyclic ConditionsMax Individual Length: 0.073" Max Individual Width: 0.073" Max Cumulative Length: 0.218" in 2.616" of w

UNDERCUTTINGNormal Services: Not a factor for normal service

Severe Cyclic: Zero allowed

CONCAVE ROOT SURFACE (SUCK-UP)Normal Service and Severe Cyclic: Unacceptable if concave root is darker than the wall

INTERNAL POROSITYRelevant Indication: 0.016

Normal Services:

Max Size of Random Internal Porosity: 0.055" Max Size of Isolated Internal Porosity: 0.073"Max Sum of diameters of Aligned Porosity: 0.218" in a 2.616" length of weldMax group length of Aligned Internal Porosity: 0.250"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 0.436"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.0"

Severe Cyclic:Max size of Random Internal Porosity: 0.055" Max Size of Isolated Internal Porosity: 0.073"Max sum of diameters of Aligned Porosity: 0.218" in a 2.616" length of weldMax group length of Aligned Internal Porosity: 0.250"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 0.436"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.0"

Page 274: NDT Code Book Made Easy

s

B31.320" Standard - 0.375" Wall

PENETRAMETER SELECTIONNote: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Hole: 15 S/S Wire: 0.010 Esn. Wire: A1 or B6

F/S Hole: 12 F/S Wire: 0.008 Esn. Wire: A2Welds with reinforcement: S/S Hole: 17 S/S Wire: 0.013 Esn. Wire: B5

F/S Hole: 15 S/S Wire: 0.010 Esn. Wire: A1 or B6Maximum allowable reinforcement: 0.125" Total of wall + reinforcement: 0.500"CRACKS AND LACK OF FUSIONNone Allowed

INCOMPLETE PENETRATIONNormal ServiceGirth and Miter Groove, Branch Connections: Max 1.5" in a 6" length of weld.Longitudinal Groove: None allowed

Severe CyclicGirth and Miter Groove, Branch Connections, and Longitudinal Groove: None allowed

SLAG INCLUSION, TUNGSTEN INCLUSION, OR ELONGATED INDICATIONNormal ServiceMax Individual Length: 0.750" Max Individual Width: 0.125" Max Cumulative Length: 1.500" in 6" of weld

Severe Cyclic ConditionsMax Individual Length: 0.125" Max Individual Width: 0.094" Max Cumulative Length: 0.375" in 4.5" of w

UNDERCUTTINGNormal Services: Not a factor for normal service

Severe Cyclic: Zero allowed

CONCAVE ROOT SURFACE (SUCK-UP)Normal Service and Severe Cyclic: Unacceptable if concave root is darker than the wall

INTERNAL POROSITYRelevant Indication: 0.031

Normal Services:

Max Size of Random Internal Porosity: 0.141" Max Size of Isolated Internal Porosity: 0.188"Max Sum of diameters of Aligned Porosity: 0.563" in a 4.5" length of weldMax group length of Aligned Internal Porosity: 0.375"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 1.125"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.5"

Severe Cyclic:Max size of Random Internal Porosity: 0.094" Max Size of Isolated Internal Porosity: 0.125"Max sum of diameters of Aligned Porosity: 0.375" in a 4.5" length of weldMax group length of Aligned Internal Porosity: 0.250"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 0.750"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.0"

Page 275: NDT Code Book Made Easy

s

B31.320" s/40 - 0.594" Wall

PENETRAMETER SELECTIONNote: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Hole: 20 S/S Wire: 0.016 Esn. Wire: B4

F/S Hole: 17 F/S Wire: 0.013 Esn. Wire: B5Welds with reinforcement: S/S Hole: 20 S/S Wire: 0.016 Esn. Wire: B4

F/S Hole: 17 S/S Wire: 0.013 Esn. Wire: B5Maximum allowable reinforcement: 0.156" Total of wall + reinforcement: 0.750"CRACKS AND LACK OF FUSIONNone Allowed

INCOMPLETE PENETRATIONNormal ServiceGirth and Miter Groove, Branch Connections: Max 1.5" in a 6" length of weld.Longitudinal Groove: None allowed

Severe CyclicGirth and Miter Groove, Branch Connections, and Longitudinal Groove: None allowed

SLAG INCLUSION, TUNGSTEN INCLUSION, OR ELONGATED INDICATIONNormal ServiceMax Individual Length: 1.188" Max Individual Width: 0.125" Max Cumulative Length: 2.376" in 6" of weld

Severe Cyclic ConditionsMax Individual Length: 0.198" Max Individual Width: 0.094" Max Cumulative Length: 0.594" in 7.128" of w

UNDERCUTTINGNormal Services: Not a factor for normal service

Severe Cyclic: Zero allowed

CONCAVE ROOT SURFACE (SUCK-UP)Normal Service and Severe Cyclic: Unacceptable if concave root is darker than the wall

INTERNAL POROSITYRelevant Indication: 0.031

Normal Services:

Max Size of Random Internal Porosity: 0.223" Max Size of Isolated Internal Porosity: 0.297"Max Sum of diameters of Aligned Porosity: 0.891" in a 7.128" length of weldMax group length of Aligned Internal Porosity: 0.375"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 1.500"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.5"

Severe Cyclic:Max size of Random Internal Porosity: 0.149" Max Size of Isolated Internal Porosity: 0.198"Max sum of diameters of Aligned Porosity: 0.594" in a 7.128" length of weldMax group length of Aligned Internal Porosity: 0.250"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 1.000"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.0"

Page 276: NDT Code Book Made Easy

s

B31.320" Extra Strong - 0.500" Wall

PENETRAMETER SELECTIONNote: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Hole: 17 S/S Wire: 0.013 Esn. Wire: B5

F/S Hole: 15 F/S Wire: 0.010 Esn. Wire: A1 or B6Welds with reinforcement: S/S Hole: 20 S/S Wire: 0.016 Esn. Wire: B4

F/S Hole: 17 S/S Wire: 0.013 Esn. Wire: B5Maximum allowable reinforcement: 0.125" Total of wall + reinforcement: 0.625"CRACKS AND LACK OF FUSIONNone Allowed

INCOMPLETE PENETRATIONNormal ServiceGirth and Miter Groove, Branch Connections: Max 1.5" in a 6" length of weld.Longitudinal Groove: None allowed

Severe CyclicGirth and Miter Groove, Branch Connections, and Longitudinal Groove: None allowed

SLAG INCLUSION, TUNGSTEN INCLUSION, OR ELONGATED INDICATIONNormal ServiceMax Individual Length: 1.000" Max Individual Width: 0.125" Max Cumulative Length: 2.000" in 6" of weld

Severe Cyclic ConditionsMax Individual Length: 0.167" Max Individual Width: 0.094" Max Cumulative Length: 0.500" in 6.000"/w

UNDERCUTTINGNormal Services: Not a factor for normal service

Severe Cyclic: Zero allowed

CONCAVE ROOT SURFACE (SUCK-UP)Normal Service and Severe Cyclic: Unacceptable if concave root is darker than the wall

INTERNAL POROSITYRelevant Indication: 0.031

Normal Services:

Max Size of Random Internal Porosity: 0.188" Max Size of Isolated Internal Porosity: 0.250"Max Sum of diameters of Aligned Porosity: 0.750" in a 6.0" length of weldMax group length of Aligned Internal Porosity: 0.375"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 1.500"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.5"

Severe Cyclic:Max size of Random Internal Porosity: 0.125" Max Size of Isolated Internal Porosity: 0.167"Max sum of diameters of Aligned Porosity: 0.500" in a 6.0" length of weldMax group length of Aligned Internal Porosity: 0.250"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 1.000"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.0"

Page 277: NDT Code Book Made Easy

s

B31.320" s/80 - 1.031" Wall

PENETRAMETER SELECTIONNote: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Hole: 30 S/S Wire: 0.025 Esn. Wire: B2

F/S Hole: 25 F/S Wire: 0.020 Esn. Wire: B3Welds with reinforcement: S/S Hole: 30 S/S Wire: 0.025 Esn. Wire: B2

F/S Hole: 25 S/S Wire: 0.020 Esn. Wire: B3Maximum allowable reinforcement: 0.188" Total of wall + reinforcement: 1.219"CRACKS AND LACK OF FUSIONNone Allowed

INCOMPLETE PENETRATIONNormal ServiceGirth and Miter Groove, Branch Connections: Max 1.5" in a 6" length of weld.Longitudinal Groove: None allowed

Severe CyclicGirth and Miter Groove, Branch Connections, and Longitudinal Groove: None allowed

SLAG INCLUSION, TUNGSTEN INCLUSION, OR ELONGATED INDICATIONNormal ServiceMax Individual Length: 2.062" Max Individual Width: 0.125" Max Cumulative Length: 4.124" in 6" of weld

Severe Cyclic ConditionsMax Individual Length: 0.344" Max Individual Width: 0.094" Max Cumulative Length: 1.031" in 12.372"/w

UNDERCUTTINGNormal Services: Not a factor for normal service

Severe Cyclic: Zero allowed

CONCAVE ROOT SURFACE (SUCK-UP)Normal Service and Severe Cyclic: Unacceptable if concave root is darker than the wall

INTERNAL POROSITYRelevant Indication: 0.031

Normal Services:

Max Size of Random Internal Porosity: 0.234" Max Size of Isolated Internal Porosity: 0.375"Max Sum of diameters of Aligned Porosity: 1.547" in a 12.372" length of weldMax group length of Aligned Internal Porosity: 0.516"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 1.500"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.5"

Severe Cyclic:Max size of Random Internal Porosity: 0.156" Max Size of Isolated Internal Porosity: 0.250"Max sum of diameters of Aligned Porosity: 1.031" in a 12.372" length of weldMax group length of Aligned Internal Porosity: 0.344"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 1.000"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.0"

Page 278: NDT Code Book Made Easy

s

B31.320" s/120 - 1.500" Wall

PENETRAMETER SELECTIONNote: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Hole: 30 S/S Wire: 0.025 Esn. Wire: B2

F/S Hole: 25 F/S Wire: 0.020 Esn. Wire: B3Welds with reinforcement: S/S Hole: 35 S/S Wire: 0.032 Esn. Wire: B1 or C6

F/S Hole: 30 S/S Wire: 0.025 Esn. Wire: B2Maximum allowable reinforcement: 0.188" Total of wall + reinforcement: 1.688"CRACKS AND LACK OF FUSIONNone Allowed

INCOMPLETE PENETRATIONNormal ServiceGirth and Miter Groove, Branch Connections: Max 1.5" in a 6" length of weld.Longitudinal Groove: None allowed

Severe CyclicGirth and Miter Groove, Branch Connections, and Longitudinal Groove: None allowed

SLAG INCLUSION, TUNGSTEN INCLUSION, OR ELONGATED INDICATIONNormal ServiceMax Individual Length: 3.00" Max Individual Width: 0.125" Max Cumulative Length: 6" in 6" of weld

Severe Cyclic ConditionsMax Individual Length: 0.500" Max Individual Width: 0.094" Max Cumulative Length: 1.500" in 18.00"/w

UNDERCUTTINGNormal Services: Not a factor for normal service

Severe Cyclic: Zero allowed

CONCAVE ROOT SURFACE (SUCK-UP)Normal Service and Severe Cyclic: Unacceptable if concave root is darker than the wall

INTERNAL POROSITYRelevant Indication: 0.031

Normal Services:

Max Size of Random Internal Porosity: 0.234" Max Size of Isolated Internal Porosity: 0.375"Max Sum of diameters of Aligned Porosity: 2.250" in a 18.00" length of weldMax group length of Aligned Internal Porosity: 0.750"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 1.500"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.5"

Severe Cyclic:Max size of Random Internal Porosity: 0.156" Max Size of Isolated Internal Porosity: 0.250"Max sum of diameters of Aligned Porosity: 1.500" in a 18.00" length of weldMax group length of Aligned Internal Porosity: 0.500"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 1.000"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.0"

Page 279: NDT Code Book Made Easy

s

B31.320" s/160 - 1.969" Wall

PENETRAMETER SELECTIONNote: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Hole: 35 S/S Wire: 0.032 Esn. Wire: B1 or C6

F/S Hole: 30 F/S Wire: 0.025 Esn. Wire: B2Welds with reinforcement: S/S Hole: 40 S/S Wire: 0.040 Esn. Wire: C5

F/S Hole: 35 S/S Wire: 0.032 Esn. Wire: B1 or C6Maximum allowable reinforcement: 0.188" Total of wall + reinforcement: 2.157"CRACKS AND LACK OF FUSIONNone Allowed

INCOMPLETE PENETRATIONNormal ServiceGirth and Miter Groove, Branch Connections: Max 1.5" in a 6" length of weld.Longitudinal Groove: None allowed

Severe CyclicGirth and Miter Groove, Branch Connections, and Longitudinal Groove: None allowed

SLAG INCLUSION, TUNGSTEN INCLUSION, OR ELONGATED INDICATIONNormal ServiceMax Individual Length: 3.938" Max Individual Width: 0.125" Max Cumulative Length: 7.876" in 6" of weld

Severe Cyclic ConditionsMax Individual Length: 0.656" Max Individual Width: 0.094" Max Cumulative Length: 1.696" in 23.628"/w

UNDERCUTTINGNormal Services: Not a factor for normal service

Severe Cyclic: Zero allowed

CONCAVE ROOT SURFACE (SUCK-UP)Normal Service and Severe Cyclic: Unacceptable if concave root is darker than the wall

INTERNAL POROSITYRelevant Indication: 0.031

Normal Services:

Max Size of Random Internal Porosity: 0.234" Max Size of Isolated Internal Porosity: 0.375"Max Sum of diameters of Aligned Porosity: 2.954" in a 23.628" length of weldMax group length of Aligned Internal Porosity: 0.985"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 1.500"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.5"

Severe Cyclic:Max size of Random Internal Porosity: 0.156" Max Size of Isolated Internal Porosity: 0.250"Max sum of diameters of Aligned Porosity: 1.969" in a 23.628" length of weldMax group length of Aligned Internal Porosity: 0.656"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 1.000"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.0"

Page 280: NDT Code Book Made Easy

s

B31.324" s/10 - .250" Wall

PENETRAMETER SELECTIONNote: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Hole: 12 S/S Wire: 0.008 Esn. Wire: A2

F/S Hole: 10 F/S Wire: 0.006 Esn. Wire: A3Welds with reinforcement: S/S Hole: 15 S/S Wire: 0.010 Esn. Wire: A1 or B6

F/S Hole: 12 S/S Wire: 0.008 Esn. Wire: A2Maximum allowable reinforcement: 0.0625" Total of wall + reinforcement: 0.313"CRACKS AND LACK OF FUSIONNone Allowed

INCOMPLETE PENETRATIONNormal ServiceGirth and Miter Groove, Branch Connections: Max 1.5" in a 6" length of weld.Longitudinal Groove: None allowed

Severe CyclicGirth and Miter Groove, Branch Connections, and Longitudinal Groove: None allowed

SLAG INCLUSION, TUNGSTEN INCLUSION, OR ELONGATED INDICATIONNormal ServiceMax Individual Length: 0.500" Max Individual Width: 0.125" Max Cumulative Length: 1.00" in 6" of weld

Severe Cyclic ConditionsMax Individual Length: 0.083" Max Individual Width: 0.083" Max Cumulative Length: 0.250" in 3.00" of w

UNDERCUTTINGNormal Services: Not a factor for normal service

Severe Cyclic: Zero allowed

CONCAVE ROOT SURFACE (SUCK-UP)Normal Service and Severe Cyclic: Unacceptable if concave root is darker than the wall

INTERNAL POROSITYRelevant Indication: 0.016

Normal Services:

Max Size of Random Internal Porosity: 0.063" Max Size of Isolated Internal Porosity: 0.083"Max Sum of diameters of Aligned Porosity: 0.250" in a 3.000" length of weldMax group length of Aligned Internal Porosity: 0.250"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 0.500"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.0"

Severe Cyclic:Max size of Random Internal Porosity: 0.063" Max Size of Isolated Internal Porosity: 0.083"Max sum of diameters of Aligned Porosity: 0.250" in a 3.000" length of weldMax group length of Aligned Internal Porosity: 0.250"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 0.500"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.0"

Page 281: NDT Code Book Made Easy

s

B31.324" s/40 - 0.688" Wall

PENETRAMETER SELECTIONNote: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Hole: 20 S/S Wire: 0.016 Esn. Wire: B4

F/S Hole: 17 F/S Wire: 0.013 Esn. Wire: B5Welds with reinforcement: S/S Hole: 25 S/S Wire: 0.020 Esn. Wire: B3

F/S Hole: 20 S/S Wire: 0.016 Esn. Wire: B4Maximum allowable reinforcement: 0.156" Total of wall + reinforcement: 0.844"CRACKS AND LACK OF FUSIONNone Allowed

INCOMPLETE PENETRATIONNormal ServiceGirth and Miter Groove, Branch Connections: Max 1.5" in a 6" length of weld.Longitudinal Groove: None allowed

Severe CyclicGirth and Miter Groove, Branch Connections, and Longitudinal Groove: None allowed

SLAG INCLUSION, TUNGSTEN INCLUSION, OR ELONGATED INDICATIONNormal ServiceMax Individual Length: 1.376" Max Individual Width: 0.125" Max Cumulative Length: 2.752" in 6" of weld

Severe Cyclic ConditionsMax Individual Length: 0.229" Max Individual Width: 0.094 Max Cumulative Length: 0.688" in 8.256"/w

UNDERCUTTINGNormal Services: Not a factor for normal service

Severe Cyclic: Zero allowed

CONCAVE ROOT SURFACE (SUCK-UP)Normal Service and Severe Cyclic: Unacceptable if concave root is darker than the wall

INTERNAL POROSITYRelevant Indication: 0.031

Normal Services:

Max Size of Random Internal Porosity: 0.234" Max Size of Isolated Internal Porosity: 0.344"Max Sum of diameters of Aligned Porosity: 1.032" in a 8.256" length of weldMax group length of Aligned Internal Porosity: 0.375"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 1.500"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.5"

Severe Cyclic:Max size of Random Internal Porosity: 0.156" Max Size of Isolated Internal Porosity: 0.229"Max sum of diameters of Aligned Porosity: 0.688" in a 8.256" length of weldMax group length of Aligned Internal Porosity: 0.250"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 1.000"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.0"

Page 282: NDT Code Book Made Easy

s

B31.324" Standard - 0.375" Wall

PENETRAMETER SELECTIONNote: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Hole: 15 S/S Wire: 0.010 Esn. Wire: A1 or B6

F/S Hole: 12 F/S Wire: 0.008 Esn. Wire: A2Welds with reinforcement: S/S Hole: 17 S/S Wire: 0.013 Esn. Wire: B5

F/S Hole: 15 S/S Wire: 0.010 Esn. Wire: A1 or B6Maximum allowable reinforcement: 0.125" Total of wall + reinforcement: 0.500"CRACKS AND LACK OF FUSIONNone Allowed

INCOMPLETE PENETRATIONNormal ServiceGirth and Miter Groove, Branch Connections: Max 1.5" in a 6" length of weld.Longitudinal Groove: None allowed

Severe CyclicGirth and Miter Groove, Branch Connections, and Longitudinal Groove: None allowed

SLAG INCLUSION, TUNGSTEN INCLUSION, OR ELONGATED INDICATIONNormal ServiceMax Individual Length: 0.750" Max Individual Width: 0.125" Max Cumulative Length: 1.500" in 6" of weld

Severe Cyclic ConditionsMax Individual Length: 0.125" Max Individual Width: 0.094 Max Cumulative Length: 0.375" in 4.5" of w

UNDERCUTTINGNormal Services: Not a factor for normal service

Severe Cyclic: Zero allowed

CONCAVE ROOT SURFACE (SUCK-UP)Normal Service and Severe Cyclic: Unacceptable if concave root is darker than the wall

INTERNAL POROSITYRelevant Indication: 0.031

Normal Services:

Max Size of Random Internal Porosity: 0.141" Max Size of Isolated Internal Porosity: 0.188"Max Sum of diameters of Aligned Porosity: 0.563" in a 4.500" length of weldMax group length of Aligned Internal Porosity: 0.375"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 1.125"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.5"

Severe Cyclic:Max size of Random Internal Porosity: 0.094" Max Size of Isolated Internal Porosity: 0.125"Max sum of diameters of Aligned Porosity: 0.375" in a 4.500" length of weldMax group length of Aligned Internal Porosity: 0.250"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 0.750"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.0"

Page 283: NDT Code Book Made Easy

e

s

B31.324" Extra Strong - 0.500" Wall

PENETRAMETER SELECTIONNote: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforc ` S/S Hole: 17 S/S Wire: 0.013 Esn. Wire: B5

F/S Hole: 15 F/S Wire: 0.010 Esn. Wire: A1 or B6Welds with reinforcement: S/S Hole: 20 S/S Wire: 0.016 Esn. Wire: B4

F/S Hole: 17 S/S Wire: 0.013 Esn. Wire: B5Maximum allowable reinforcement: 0.125" Total of wall + reinforcement: 0.625"CRACKS AND LACK OF FUSIONNone Allowed

INCOMPLETE PENETRATIONNormal ServiceGirth and Miter Groove, Branch Connections: Max 1.5" in a 6" length of weld.Longitudinal Groove: None allowed

Severe CyclicGirth and Miter Groove, Branch Connections, and Longitudinal Groove: None allowed

SLAG INCLUSION, TUNGSTEN INCLUSION, OR ELONGATED INDICATIONNormal ServiceMax Individual Length: 1.000" Max Individual Width: 0.125" Max Cumulative Length: 2.000" in 6" of weld

Severe Cyclic ConditionsMax Individual Length: 0.167" Max Individual Width: 0.094 Max Cumulative Length: 0.500" in 6.000"/w

UNDERCUTTINGNormal Services: Not a factor for normal service

Severe Cyclic: Zero allowed

CONCAVE ROOT SURFACE (SUCK-UP)Normal Service and Severe Cyclic: Unacceptable if concave root is darker than the wall

INTERNAL POROSITYRelevant Indication: 0.031

Normal Services:

Max Size of Random Internal Porosity: 0.188" Max Size of Isolated Internal Porosity: 0.250"Max Sum of diameters of Aligned Porosity: 0.750" in a 6.000" length of weldMax group length of Aligned Internal Porosity: 0.375"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 1.500"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.5"

Severe Cyclic:Max size of Random Internal Porosity: 0.125" Max Size of Isolated Internal Porosity: 0.167"Max sum of diameters of Aligned Porosity: 0.500" in a 6.000" length of weldMax group length of Aligned Internal Porosity: 0.250"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 1.000"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.0"

Page 284: NDT Code Book Made Easy

s

B31.324" s/80 - 1.218" Wall

PENETRAMETER SELECTIONNote: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Hole: 30 S/S Wire: 0.025 Esn. Wire: B2

F/S Hole: 25 F/S Wire: 0.020 Esn. Wire: B3Welds with reinforcement: S/S Hole: 30 S/S Wire: 0.025 Esn. Wire: B2

F/S Hole: 25 S/S Wire: 0.020 Esn. Wire: B3Maximum allowable reinforcement: 0.188" Total of wall + reinforcement: 1.406"CRACKS AND LACK OF FUSIONNone Allowed

INCOMPLETE PENETRATIONNormal ServiceGirth and Miter Groove, Branch Connections: Max 1.5" in a 6" length of weld.Longitudinal Groove: None allowed

Severe CyclicGirth and Miter Groove, Branch Connections, and Longitudinal Groove: None allowed

SLAG INCLUSION, TUNGSTEN INCLUSION, OR ELONGATED INDICATIONNormal ServiceMax Individual Length: 2.438" Max Individual Width: 0.125" Max Cumulative Length: 4.876" in 6" of weld

Severe Cyclic ConditionsMax Individual Length: 0.406" Max Individual Width: 0.094 Max Cumulative Length: 1.219" in 14.628"/w

UNDERCUTTINGNormal Services: Not a factor for normal service

Severe Cyclic: Zero allowed

CONCAVE ROOT SURFACE (SUCK-UP)Normal Service and Severe Cyclic: Unacceptable if concave root is darker than the wall

INTERNAL POROSITYRelevant Indication: 0.031

Normal Services:

Max Size of Random Internal Porosity: 0.234" Max Size of Isolated Internal Porosity: 0.375"Max Sum of diameters of Aligned Porosity: 1.829" in a 14.628" length of weldMax group length of Aligned Internal Porosity: 0.610"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 1.500"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.5"

Severe Cyclic:Max size of Random Internal Porosity: 0.156" Max Size of Isolated Internal Porosity: 0.250"Max sum of diameters of Aligned Porosity: 1.219" in a 14.628" length of weldMax group length of Aligned Internal Porosity: 0.406"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 1.000"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.0"

Page 285: NDT Code Book Made Easy

s

B31.324" s/160 - 2.344" Wall

PENETRAMETER SELECTIONNote: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Hole: 40 S/S Wire: 0.040 Esn. Wire: C5

F/S Hole: 35 F/S Wire: 0.032 Esn. Wire: B1 or C6Welds with reinforcement: S/S Hole: 50 S/S Wire: 0.050 Esn. Wire: C4

F/S Hole: 40 S/S Wire: 0.040 Esn. Wire: C5Maximum allowable reinforcement: 0.188" Total of wall + reinforcement: 2.532"CRACKS AND LACK OF FUSIONNone Allowed

INCOMPLETE PENETRATIONNormal ServiceGirth and Miter Groove, Branch Connections: Max 1.5" in a 6" length of weld.Longitudinal Groove: None allowed

Severe CyclicGirth and Miter Groove, Branch Connections, and Longitudinal Groove: None allowed

SLAG INCLUSION, TUNGSTEN INCLUSION, OR ELONGATED INDICATIONNormal ServiceMax Individual Length: 4.688" Max Individual Width: 0.125" Max Cumulative Length: 9.376" in 6" of weld

Severe Cyclic ConditionsMax Individual Length: 0.781" Max Individual Width: 0.094 Max Cumulative Length: 2.344" in 28.128"/w

UNDERCUTTINGNormal Services: Not a factor for normal service

Severe Cyclic: Zero allowed

CONCAVE ROOT SURFACE (SUCK-UP)Normal Service and Severe Cyclic: Unacceptable if concave root is darker than the wall

INTERNAL POROSITYRelevant Indication: 0.031

Normal Services:

Max Size of Random Internal Porosity: 0.234" Max Size of Isolated Internal Porosity: 0.563"Max Sum of diameters of Aligned Porosity: 3.516" in a 28.128" length of weldMax group length of Aligned Internal Porosity: 1.125"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 1.500"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.5"

Severe Cyclic:Max size of Random Internal Porosity: 0.156" Max Size of Isolated Internal Porosity: 0.375"Max sum of diameters of Aligned Porosity: 2.344" in a 28.128" length of weldMax group length of Aligned Internal Porosity: 0.750"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 1.000"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.0"

Page 286: NDT Code Book Made Easy

s

B31.336" s/10 - 0.312" Wall

PENETRAMETER SELECTIONNote: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Hole: 15 S/S Wire: 0.010 Esn. Wire: A1 or B6

F/S Hole: 12 F/S Wire: 0.008 Esn. Wire: A2Welds with reinforcement: S/S Hole: 17 S/S Wire: 0.013 Esn. Wire: B5

F/S Hole: 15 S/S Wire: 0.010 Esn. Wire: A1 or B6Maximum allowable reinforcement: 0.125" Total of wall + reinforcement: 0.437"CRACKS AND LACK OF FUSIONNone Allowed

INCOMPLETE PENETRATIONNormal ServiceGirth and Miter Groove, Branch Connections: Max 1.5" in a 6" length of weld.Longitudinal Groove: None allowed

Severe CyclicGirth and Miter Groove, Branch Connections, and Longitudinal Groove: None allowed

SLAG INCLUSION, TUNGSTEN INCLUSION, OR ELONGATED INDICATIONNormal ServiceMax Individual Length: 0.624" Max Individual Width: 0.125" Max Cumulative Length: 1.248" in 6" of weld

Severe Cyclic ConditionsMax Individual Length: 0.104" Max Individual Width: 0.094" Max Cumulative Length: 0.312" in 3.744"/w

UNDERCUTTINGNormal Services: Not a factor for normal service

Severe Cyclic: Zero allowed

CONCAVE ROOT SURFACE (SUCK-UP)Normal Service and Severe Cyclic: Unacceptable if concave root is darker than the wall

INTERNAL POROSITYRelevant Indication: 0.031

Normal Services:

Max Size of Random Internal Porosity: 0.117" Max Size of Isolated Internal Porosity: 0.156"Max Sum of diameters of Aligned Porosity: 0.468" in a 3.744" length of weldMax group length of Aligned Internal Porosity: 0.375"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 0.936"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.5"

Severe Cyclic:Max size of Random Internal Porosity: 0.078" Max Size of Isolated Internal Porosity: 0.104"Max sum of diameters of Aligned Porosity: 0.312" in a 3.744" length of weldMax group length of Aligned Internal Porosity: 0.250"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 0.624"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.0"

Page 287: NDT Code Book Made Easy

s

B31.336" Standard - 0.375" Wall

PENETRAMETER SELECTIONNote: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Hole: 15 S/S Wire: 0.010 Esn. Wire: A1 or B6

F/S Hole: 12 F/S Wire: 0.008 Esn. Wire: A2Welds with reinforcement: S/S Hole: 17 S/S Wire: 0.013 Esn. Wire: B5

F/S Hole: 15 S/S Wire: 0.010 Esn. Wire: A1 or B6Maximum allowable reinforcement: 0.125" Total of wall + reinforcement: 0.500"CRACKS AND LACK OF FUSIONNone Allowed

INCOMPLETE PENETRATIONNormal ServiceGirth and Miter Groove, Branch Connections: Max 1.5" in a 6" length of weld.Longitudinal Groove: None allowed

Severe CyclicGirth and Miter Groove, Branch Connections, and Longitudinal Groove: None allowed

SLAG INCLUSION, TUNGSTEN INCLUSION, OR ELONGATED INDICATIONNormal ServiceMax Individual Length: 0.750" Max Individual Width: 0.125" Max Cumulative Length: 1.500" in 6" of weld

Severe Cyclic ConditionsMax Individual Length: 0.125" Max Individual Width: 0.094" Max Cumulative Length: 0.375" in 4.500"/w

UNDERCUTTINGNormal Services: Not a factor for normal service

Severe Cyclic: Zero allowed

CONCAVE ROOT SURFACE (SUCK-UP)Normal Service and Severe Cyclic: Unacceptable if concave root is darker than the wall

INTERNAL POROSITYRelevant Indication: 0.031

Normal Services:

Max Size of Random Internal Porosity: 0.141" Max Size of Isolated Internal Porosity: 0.188"Max Sum of diameters of Aligned Porosity: 0.563" in a 4.500" length of weldMax group length of Aligned Internal Porosity: 0.375"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 1.125"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.5"

Severe Cyclic:Max size of Random Internal Porosity: 0.094" Max Size of Isolated Internal Porosity: 0.125"Max sum of diameters of Aligned Porosity: 0.375" in a 4.500" length of weldMax group length of Aligned Internal Porosity: 0.250"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 0.750"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.0"

Page 288: NDT Code Book Made Easy

s

B31.336" Extra Strong - 0.500" Wall

PENETRAMETER SELECTIONNote: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Hole: 17 S/S Wire: 0.013 Esn. Wire: B5

F/S Hole: 15 F/S Wire: 0.010 Esn. Wire: A1 or B6Welds with reinforcement: S/S Hole: 20 S/S Wire: 0.016 Esn. Wire: B4

F/S Hole: 17 S/S Wire: 0.013 Esn. Wire: B5Maximum allowable reinforcement: 0.125" Total of wall + reinforcement: 0.625"CRACKS AND LACK OF FUSIONNone Allowed

INCOMPLETE PENETRATIONNormal ServiceGirth and Miter Groove, Branch Connections: Max 1.5" in a 6" length of weld.Longitudinal Groove: None allowed

Severe CyclicGirth and Miter Groove, Branch Connections, and Longitudinal Groove: None allowed

SLAG INCLUSION, TUNGSTEN INCLUSION, OR ELONGATED INDICATIONNormal ServiceMax Individual Length: 1.000" Max Individual Width: 0.125" Max Cumulative Length: 2.000" in 6" of weld

Severe Cyclic ConditionsMax Individual Length: 0.167" Max Individual Width: 0.094" Max Cumulative Length: 0.500" in 6.000"/w

UNDERCUTTINGNormal Services: Not a factor for normal service

Severe Cyclic: Zero allowed

CONCAVE ROOT SURFACE (SUCK-UP)Normal Service and Severe Cyclic: Unacceptable if concave root is darker than the wall

INTERNAL POROSITYRelevant Indication: 0.031

Normal Services:

Max Size of Random Internal Porosity: 0.188" Max Size of Isolated Internal Porosity: 0.250"Max Sum of diameters of Aligned Porosity: 0.750" in a 6.000" length of weldMax group length of Aligned Internal Porosity: 0.375"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 1.500"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.5"

Severe Cyclic:Max size of Random Internal Porosity: 0.125" Max Size of Isolated Internal Porosity: 0.167"Max sum of diameters of Aligned Porosity: 0.500" in a 6.000" length of weldMax group length of Aligned Internal Porosity: 0.250"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 1.000"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.0"

Page 289: NDT Code Book Made Easy

s

B31.336" s/40 - 0.750" Wall

PENETRAMETER SELECTIONNote: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Hole: 20 S/S Wire: 0.016 Esn. Wire: B4

F/S Hole: 17 F/S Wire: 0.013 Esn. Wire: B5Welds with reinforcement: S/S Hole: 25 S/S Wire: 0.020 Esn. Wire: B3

F/S Hole: 20 S/S Wire: 0.016 Esn. Wire: B4Maximum allowable reinforcement: 0.156" Total of wall + reinforcement: 0.906"CRACKS AND LACK OF FUSIONNone Allowed

INCOMPLETE PENETRATIONNormal ServiceGirth and Miter Groove, Branch Connections: Max 1.5" in a 6" length of weld.Longitudinal Groove: None allowed

Severe CyclicGirth and Miter Groove, Branch Connections, and Longitudinal Groove: None allowed

SLAG INCLUSION, TUNGSTEN INCLUSION, OR ELONGATED INDICATIONNormal ServiceMax Individual Length: 1.500" Max Individual Width: 0.125" Max Cumulative Length: 3.00" in 6" of weld

Severe Cyclic ConditionsMax Individual Length: 0.250" Max Individual Width: 0.094" Max Cumulative Length: 0.750" in 9.00"/w

UNDERCUTTINGNormal Services: Not a factor for normal service

Severe Cyclic: Zero allowed

CONCAVE ROOT SURFACE (SUCK-UP)Normal Service and Severe Cyclic: Unacceptable if concave root is darker than the wall

INTERNAL POROSITYRelevant Indication: 0.031

Normal Services:

Max Size of Random Internal Porosity: 0.234" Max Size of Isolated Internal Porosity: 0.375"Max Sum of diameters of Aligned Porosity: 1.125" in a 9.00" length of weldMax group length of Aligned Internal Porosity: 0.375"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 1.500"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.5"

Severe Cyclic:Max size of Random Internal Porosity: 0.156" Max Size of Isolated Internal Porosity: 0.250"Max sum of diameters of Aligned Porosity: 0.750" in a 9.00" length of weldMax group length of Aligned Internal Porosity: 0.250"Max group length of Cluster Internal Porosity if 1 group is present in a 6" length of weld: 1.000"Max group length of Cluster Internal Porosity if more than 1 group is present in a 6" length of weld: 1.0"

Page 290: NDT Code Book Made Easy

S

ASME SECTION VIII - PLATE ONLY

1/16" Plate - 0.0625" Wall

PENETRAMETER SELECTIONNote: Esn. Wire: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Hole 12 S/S Wire: 0.008 Esn Wire: A2 F/S Hole: 10 F/S Wire: 0.006 Esn Wire: A3Reinforced welds welded fromone side: S/S Hole: 12 S/S Wire: 0.008 Esn. Wire: A2

F/S Hole: 10 S/S Wire: 0.006 Esn. Wire: A3Reinforced welds welded fromtwo sides: S/S Hole: 12 S/S Wire: 0.008 Esn. Wire: A2

F/S Hole: 10 S/S Wire: 0.006 Esn. Wire: A3

Maximum allowable reinforcement if welded from one side: 0.031" Total of Wall + Reinforcement 0.094"Maximum allowable reinforcement if welded from two sides: 0.063" Total of Wall + Reinforcement 0.125"

PENETRAMETER SELECTION FOR API 620, 650, & 653Welds without reinforcement: Same as aboveWelds with reinforcement: S/S Hole: 12 S/S Wire: 0.008 Esn. Wire: A2

F/S Hole: 10 F/S Wire: 0.006 Esn. Wire: A3

Maximum allowable reinforcement: 0.0625" Total of Wall + Reinforcement 0.125"

UW-51; API 620, 650, & 653Cracks, Incomplete Penetration, and Incomplete Fusion: None AllowedOther Elongated Indications (UW-51 only):Max Length of other elongated indications: 0.250"Max Cumulative length of aligned indications is 0.0625" in a length of weld equal to 0.750" unlessseperated by the length of 6L Rounded Indications (UW-51 Only):Relevant Indications: 0.006Max Size of Random Indications: 0.016" Max Size of Isolated Rounded Indications: 0.021"Max sum of diameters of Aligned Rounded Indications: 0.0625" in a 0.750" length of weldMax group length of Aligned Rounded Indications: 0.250"Max group length of Cluster Rounded Indications if 1 group is present in a 6" length of weld: 0.125"Max group length of Cluster Rounded Indications if more than 1 group is present in a 6" length of weld: 1.0"

UW-52Cracks, Incomplete Penetration, and Incomplete Fusion: None AllowedSlag Inclusions:Max Size of slag inclusions: 0.250"Max Cumulative length of acceptable in-line indications (other than rounded): 0.0625" in a 0.375" length ofwelds and must be seperated by the length of 3L of acceptable weld metal.

Technique Sheet Info (Source Side of Object to Film and Source Distances)Reinforcement is found in the applicable penetrameter selection boxes above.

Source to Source Side of Object; As measured in the field.Source Side of Object to Film Distance: 0.0625"

Page 291: NDT Code Book Made Easy

S

ASME SECTION VIII - PLATE ONLY

1 13/16" Plate - 1.8125" Wall

PENETRAMETER SELECTIONNote: Esn. Wire: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Hole 35 S/S Wire: 0.032 Esn Wire: B1 or C6 F/S Hole: 30 F/S Wire: 0.025 Esn Wire: B2Reinforced welds welded fromone side: S/S Hole: 35 S/S Wire: 0.032 Esn. Wire: B1 or C6

F/S Hole: 30 S/S Wire: 0.025 Esn. Wire: B2Reinforced welds welded fromtwo sides: S/S Hole: 40 S/S Wire: 0.040 Esn. Wire: C5

F/S Hole: 35 S/S Wire: 0.032 Esn. Wire: B1 or C6

Maximum allowable reinforcement if welded from one side: 0.125" Total of Wall + Reinforcement 1.938"Maximum allowable reinforcement if welded from two sides: 0.250" Total of Wall + Reinforcement 2.063"

PENETRAMETER SELECTION FOR API 620, 650, & 653Welds without reinforcement: Same as aboveWelds with reinforcement: S/S Hole: 35 S/S Wire: 0.032 Esn. Wire: B1 or C6

F/S Hole: 30 F/S Wire: 0.025 Esn. Wire: B2

Maximum allowable reinforcement: 0.125" Total of Wall + Reinforcement 1.938"

UW-51; API 620, 650, & 653Cracks, Incomplete Penetration, and Incomplete Fusion: None AllowedOther Elongated Indications (UW-51 only):Max Length of other elongated indications: 0.604"Max Cumulative length of aligned indications is 1.8125" in a length of weld equal to 21.750" unlessseperated by the length of 6L Rounded Indications (UW-51 Only):Relevant Indications: 0.031Max Size of Random Indications: 0.156" Max Size of Isolated Rounded Indications: 0.250"Max sum of diameters of Aligned Rounded Indications: 1.8125" in a 21.750" length of weldMax group length of Aligned Rounded Indications: 0.604"Max group length of Cluster Rounded Indications if 1 group is present in a 6" length of weld: 1.0"Max group length of Cluster Rounded Indications if more than 1 group is present in a 6" length of weld: 1.0"

UW-52Cracks, Incomplete Penetration, and Incomplete Fusion: None AllowedSlag Inclusions:Max Size of slag inclusions: 0.750"Max Cumulative length of acceptable in-line indications (other than rounded): 1.8125" in a 10.875" length ofwelds and must be seperated by the length of 3L of acceptable weld metal.

Technique Sheet Info (Source Side of Object to Film and Source Distances)Reinforcement is found in the applicable penetrameter selection boxes above.

Source to Source Side of Object; As measured in the field.Source Side of Object to Film Distance: 1.8125"

Page 292: NDT Code Book Made Easy

S

ASME SECTION VIII - PLATE ONLY

1 7/8" Plate- 1.875" Wall

PENETRAMETER SELECTIONNote: Esn. Wire: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Hole 35 S/S Wire: 0.032 Esn Wire: B1 or C6 F/S Hole: 30 F/S Wire: 0.025 Esn Wire: B2Reinforced welds welded fromone side: S/S Hole: 35 S/S Wire: 0.032 Esn. Wire: B1 or C6

F/S Hole: 30 S/S Wire: 0.025 Esn. Wire: B2Reinforced welds welded fromtwo sides: S/S Hole: 40 S/S Wire: 0.040 Esn. Wire: C5

F/S Hole: 35 S/S Wire: 0.032 Esn. Wire: B1 or C6

Maximum allowable reinforcement if welded from one side: 0.125" Total of Wall + Reinforcement 2.000"Maximum allowable reinforcement if welded from two sides: 0.250" Total of Wall + Reinforcement 2.125"

PENETRAMETER SELECTION FOR API 620, 650, & 653Welds without reinforcement: Same as aboveWelds with reinforcement: S/S Hole: 35 S/S Wire: 0.032 Esn. Wire: B1 or C6

F/S Hole: 30 F/S Wire: 0.025 Esn. Wire: B2

Maximum allowable reinforcement: 0.125" Total of Wall + Reinforcement 2.00"

UW-51; API 620, 650, & 653Cracks, Incomplete Penetration, and Incomplete Fusion: None AllowedOther Elongated Indications (UW-51 only):Max Length of other elongated indications: 0.625"Max Cumulative length of aligned indications is 1.875" in a length of weld equal to 22.500" unlessseperated by the length of 6L Rounded Indications (UW-51 Only):Relevant Indications: 0.031Max Size of Random Indications: 0.156" Max Size of Isolated Rounded Indications: 0.250"Max sum of diameters of Aligned Rounded Indications: 1.875" in a 22.500" length of weldMax group length of Aligned Rounded Indications: 0.625"Max group length of Cluster Rounded Indications if 1 group is present in a 6" length of weld: 1.0"Max group length of Cluster Rounded Indications if more than 1 group is present in a 6" length of weld: 1.0"

UW-52Cracks, Incomplete Penetration, and Incomplete Fusion: None AllowedSlag Inclusions:Max Size of slag inclusions: 0.750"Max Cumulative length of acceptable in-line indications (other than rounded): 1.875" in a 11.250" length ofwelds and must be seperated by the length of 3L of acceptable weld metal.

Technique Sheet Info (Source Side of Object to Film and Source Distances)Reinforcement is found in the applicable penetrameter selection boxes above.

Source to Source Side of Object; As measured in the field.Source Side of Object to Film Distance: 1.875"

Page 293: NDT Code Book Made Easy

S

ASME SECTION VIII - PLATE ONLY

3/16" Plate - 0.1875" Wall

PENETRAMETER SELECTIONNote: Esn. Wire: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Hole 12 S/S Wire: 0.032 Esn Wire: B1 or C6 F/S Hole: 30 F/S Wire: 0.025 Esn Wire: B2Reinforced welds welded fromone side: S/S Hole: 40 S/S Wire: 0.040 Esn. Wire: C5

F/S Hole: 35 S/S Wire: 0.032 Esn. Wire: B1 or C6Reinforced welds welded fromtwo sides: S/S Hole: 40 S/S Wire: 0.040 Esn. Wire: C5

F/S Hole: 35 S/S Wire: 0.032 Esn. Wire: B1 or C6

Maximum allowable reinforcement if welded from one side: 0.125" Total of Wall + Reinforcement 2.063"Maximum allowable reinforcement if welded from two sides: 0.250" Total of Wall + Reinforcement 2.188"

PENETRAMETER SELECTION FOR API 620, 650, & 653Welds without reinforcement: Same as aboveWelds with reinforcement: S/S Hole: 40 S/S Wire: 0.040 Esn. Wire: C5

F/S Hole: 35 F/S Wire: 0.032 Esn. Wire: B1 or C6

Maximum allowable reinforcement: 0.125" Total of Wall + Reinforcement 2.063"

UW-51; API 620, 650, & 653Cracks, Incomplete Penetration, and Incomplete Fusion: None AllowedOther Elongated Indications (UW-51 only):Max Length of other elongated indications: 0.646"Max Cumulative length of aligned indications is 1.9375" in a length of weld equal to 23.250" unlessseperated by the length of 6L Rounded Indications (UW-51 Only):Relevant Indications: 0.031Max Size of Random Indications: 0.156" Max Size of Isolated Rounded Indications: 0.250"Max sum of diameters of Aligned Rounded Indications: 1.9375" in a 23.250" length of weld.Max group length of Aligned Rounded Indications: 0.646"Max group length of Cluster Rounded Indications if 1 group is present in a 6" length of weld: 1.0"Max group length of Cluster Rounded Indications if more than 1 group is present in a 6" length of weld: 1.0"

UW-52Cracks, Incomplete Penetration, and Incomplete Fusion: None AllowedSlag Inclusions:Max Size of slag inclusions: 0.750"Max Cumulative length of acceptable in-line indications (other than rounded): 1.9375" in a 11.625" length ofwelds and must be seperated by the length of 3L of acceptable weld metal.

Technique Sheet Info (Source Side of Object to Film and Source Distances)Reinforcement is found in the applicable penetrameter selection boxes above.

Source to Source Side of Object; As measured in the field.Source Side of Object to Film Distance: 1.9375"

Page 294: NDT Code Book Made Easy

S

ASME SECTION VIII - PLATE ONLY

3/16" Plate - 0.1875" Wall

PENETRAMETER SELECTIONNote: Esn. Wire: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Hole 12 S/S Wire: 0.008 Esn Wire: A2 F/S Hole: 10 F/S Wire: 0.006 Esn Wire: A3Reinforced welds welded fromone side: S/S Hole: 12 S/S Wire: 0.008 Esn. Wire: A2

F/S Hole: 10 S/S Wire: 0.006 Esn. Wire: A3Reinforced welds welded fromtwo sides: S/S Hole: 15 S/S Wire: 0.010 Esn. Wire: A1 or B6

F/S Hole: 12 S/S Wire: 0.008 Esn. Wire: A2

Maximum allowable reinforcement if welded from one side: 0.0625" Total of Wall + Reinforcement 0.250"Maximum allowable reinforcement if welded from two sides: 0.125" Total of Wall + Reinforcement 0.3125"

PENETRAMETER SELECTION FOR API 620, 650, & 653Welds without reinforcement: Same as aboveWelds with reinforcement: S/S Hole: 12 S/S Wire: 0.008 Esn. Wire: A2

F/S Hole: 10 F/S Wire: 0.006 Esn. Wire: A3

Maximum allowable reinforcement: 0.0625" Total of Wall + Reinforcement 0.250"

UW-51; API 620, 650, & 653Cracks, Incomplete Penetration, and Incomplete Fusion: None AllowedOther Elongated Indications (UW-51 only):Max Length of other elongated indications: 0.250"Max Cumulative length of aligned indications is 0.1875" in a length of weld equal to 2.250" unlessseperated by the length of 6L Rounded Indications (UW-51 Only):Relevant Indications: 0.016"Max Size of Random Indications: 0.047" Max Size of Isolated Rounded Indications: 0.063"Max sum of diameters of Aligned Rounded Indications: 0.1875" in a 2.250" length of weldMax group length of Aligned Rounded Indications: 0.250"Max group length of Cluster Rounded Indications if 1 group is present in a 6" length of weld: 0.375"Max group length of Cluster Rounded Indications if more than 1 group is present in a 6" length of weld: 1.0"

UW-52Cracks, Incomplete Penetration, and Incomplete Fusion: None AllowedSlag Inclusions:Max Size of slag inclusions: 0.250"Max Cumulative length of acceptable in-line indications (other than rounded): 0.1875" in a 1.125" length ofwelds and must be seperated by the length of 3L of acceptable weld metal.

Technique Sheet Info (Source Side of Object to Film and Source Distances)Reinforcement is found in the applicable penetrameter selection boxes above.

Source to Source Side of Object; As measured in the field.Source Side of Object to Film Distance: 0.1875"

Page 295: NDT Code Book Made Easy

S

ASME SECTION VIII - PLATE ONLY

1/4" Plate - 0.250" Wall

PENETRAMETER SELECTIONNote: Esn. Wire: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Hole 12 S/S Wire: 0.008 Esn Wire: A2 F/S Hole: 10 F/S Wire: 0.006 Esn Wire: A3Reinforced welds welded fromone side: S/S Hole: 15 S/S Wire: 0.010 Esn. Wire: A1 or B6

F/S Hole: 12 S/S Wire: 0.008 Esn. Wire: A2Reinforced welds welded fromtwo sides: S/S Hole: 17 S/S Wire: 0.013 Esn. Wire: B5

F/S Hole: 15 S/S Wire: 0.010 Esn. Wire: A1 or B6

Maximum allowable reinforcement if welded from one side: 0.094" Total of Wall + Reinforcement 0.344"Maximum allowable reinforcement if welded from two sides: 0.1875" Total of Wall + Reinforcement 0.4375"

PENETRAMETER SELECTION FOR API 620, 650, & 653Welds without reinforcement: Same as aboveWelds with reinforcement: S/S Hole: 15 S/S Wire: 0.010 Esn. Wire: A1 or B6

F/S Hole: 12 F/S Wire: 0.008 Esn. Wire: A2

Maximum allowable reinforcement: 0.0625" Total of Wall + Reinforcement 0.313"

UW-51; API 620, 650, & 653Cracks, Incomplete Penetration, and Incomplete Fusion: None AllowedOther Elongated Indications (UW-51 only):Max Length of other elongated indications: 0.250"Max Cumulative length of aligned indications is 0.250" in a length of weld equal to 3.00" unlessseperated by the length of 6L Rounded Indications (UW-51 Only):Relevant Indications: 0.016"Max Size of Random Indications: 0.063" Max Size of Isolated Rounded Indications: 0.083"Max sum of diameters of Aligned Rounded Indications: 0.250" in a 3.00" length of weldMax group length of Aligned Rounded Indications: 0.250"Max group length of Cluster Rounded Indications if 1 group is present in a 6" length of weld: 0.500"Max group length of Cluster Rounded Indications if more than 1 group is present in a 6" length of weld: 1.0"

UW-52Cracks, Incomplete Penetration, and Incomplete Fusion: None AllowedSlag Inclusions:Max Size of slag inclusions: 0.250"Max Cumulative length of acceptable in-line indications (other than rounded): 0.250" in a 1.500" length ofwelds and must be seperated by the length of 3L of acceptable weld metal.

Technique Sheet Info (Source Side of Object to Film and Source Distances)Reinforcement is found in the applicable penetrameter selection boxes above.

Source to Source Side of Object; As measured in the field.Source Side of Object to Film Distance: 0.250"

Page 296: NDT Code Book Made Easy

S

ASME SECTION VIII - PLATE ONLY

5/16" Plate - 0.3125" Wall

PENETRAMETER SELECTIONNote: Esn. Wire: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Hole 15 S/S Wire: 0.010 Esn Wire: A1 or B6 F/S Hole: 12 F/S Wire: 0.008 Esn Wire: A2Reinforced welds welded fromone side: S/S Hole: 17 S/S Wire: 0.013 Esn. Wire: B5

F/S Hole: 15 S/S Wire: 0.010 Esn. Wire: A1 or B6Reinforced welds welded fromtwo sides: S/S Hole: 17 S/S Wire: 0.013 Esn. Wire: B5

F/S Hole: 15 S/S Wire: 0.010 Esn. Wire: A1 or B6

Maximum allowable reinforcement if welded from one side: 0.094" Total of Wall + Reinforcement 0.407"Maximum allowable reinforcement if welded from two sides: 0.1875" Total of Wall + Reinforcement 0.500"

PENETRAMETER SELECTION FOR API 620, 650, & 653Welds without reinforcement: Same as aboveWelds with reinforcement: S/S Hole: 15 S/S Wire: 0.010 Esn. Wire: A1 or B6

F/S Hole: 12 F/S Wire: 0.008 Esn. Wire: A2

Maximum allowable reinforcement: 0.0625" Total of Wall + Reinforcement 0.375"

UW-51; API 620, 650, & 653Cracks, Incomplete Penetration, and Incomplete Fusion: None AllowedOther Elongated Indications (UW-51 only):Max Length of other elongated indications: 0.250"Max Cumulative length of aligned indications is 0.3125" in a length of weld equal to 3.750" unlessseperated by the length of 6L Rounded Indications (UW-51 Only):Relevant Indications: 0.031Max Size of Random Indications: 0.078" Max Size of Isolated Rounded Indications: 0.104"Max sum of diameters of Aligned Rounded Indications: 0.3125" in a 3.750" length of weldMax group length of Aligned Rounded Indications: 0.250"Max group length of Cluster Rounded Indications if 1 group is present in a 6" length of weld: 0.625"Max group length of Cluster Rounded Indications if more than 1 group is present in a 6" length of weld: 1.0"

UW-52Cracks, Incomplete Penetration, and Incomplete Fusion: None AllowedSlag Inclusions:Max Size of slag inclusions: 0.250"Max Cumulative length of acceptable in-line indications (other than rounded): 0.3125" in a 1.875" length ofwelds and must be seperated by the length of 3L of acceptable weld metal.

Technique Sheet Info (Source Side of Object to Film and Source Distances)Reinforcement is found in the applicable penetrameter selection boxes above.

Source to Source Side of Object; As measured in the field.Source Side of Object to Film Distance: 0.3125"

Page 297: NDT Code Book Made Easy

S

ASME SECTION VIII - PLATE ONLY

3/8" Plate - 0.375" Wall

PENETRAMETER SELECTIONNote: Esn. Wire: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Hole 15 S/S Wire: 0.010 Esn Wire: A1 or B6 F/S Hole: 12 F/S Wire: 0.008 Esn Wire: A2Reinforced welds welded fromone side: S/S Hole: 17 S/S Wire: 0.013 Esn. Wire: B5

F/S Hole: 15 S/S Wire: 0.010 Esn. Wire: A1 or B6Reinforced welds welded fromtwo sides: S/S Hole: 20 S/S Wire: 0.016 Esn. Wire: B4

F/S Hole: 17 S/S Wire: 0.013 Esn. Wire: B5

Maximum allowable reinforcement if welded from one side: 0.094" Total of Wall + Reinforcement 0.469"Maximum allowable reinforcement if welded from two sides: 0.1875" Total of Wall + Reinforcement 0.563"

PENETRAMETER SELECTION FOR API 620, 650, & 653Welds without reinforcement: Same as aboveWelds with reinforcement: S/S Hole: 17 S/S Wire: 0.013 Esn. Wire: B5

F/S Hole: 15 F/S Wire: 0.010 Esn. Wire: A1 or B6

Maximum allowable reinforcement: 0.0625" Total of Wall + Reinforcement 0.438"

UW-51; API 620, 650, & 653Cracks, Incomplete Penetration, and Incomplete Fusion: None AllowedOther Elongated Indications (UW-51 only):Max Length of other elongated indications: 0.250"Max Cumulative length of aligned indications is 0.375" in a length of weld equal to 4.500" unlessseperated by the length of 6L Rounded Indications (UW-51 Only):Relevant Indications: 0.031Max Size of Random Indications: 0.094" Max Size of Isolated Rounded Indications: 0.125"Max sum of diameters of Aligned Rounded Indications: 0.375" in a 4.500" length of weldMax group length of Aligned Rounded Indications: 0.250"Max group length of Cluster Rounded Indications if 1 group is present in a 6" length of weld: 0.750"Max group length of Cluster Rounded Indications if more than 1 group is present in a 6" length of weld: 1.0"

UW-52Cracks, Incomplete Penetration, and Incomplete Fusion: None AllowedSlag Inclusions:Max Size of slag inclusions: 0.250"Max Cumulative length of acceptable in-line indications (other than rounded): 0.375" in a 2.250" length ofwelds and must be seperated by the length of 3L of acceptable weld metal.

Technique Sheet Info (Source Side of Object to Film and Source Distances)Reinforcement is found in the applicable penetrameter selection boxes above.

Source to Source Side of Object; As measured in the field.Source Side of Object to Film Distance: 0.375"

Page 298: NDT Code Book Made Easy

S

ASME SECTION VIII - PLATE ONLY

7/16" Plate - 0.4375" Wall

PENETRAMETER SELECTIONNote: Esn. Wire: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Hole 17 S/S Wire: 0.013 Esn Wire: B5 F/S Hole: 15 F/S Wire: 0.010 Esn Wire: A1 or B6Reinforced welds welded fromone side: S/S Hole: 20 S/S Wire: 0.016 Esn. Wire: B4

F/S Hole: 17 S/S Wire: 0.013 Esn. Wire: B5Reinforced welds welded fromtwo sides: S/S Hole: 20 S/S Wire: 0.016 Esn. Wire: B4

F/S Hole: 17 S/S Wire: 0.013 Esn. Wire: B5

Maximum allowable reinforcement if welded from one side: 0.094" Total of Wall + Reinforcement 0.532"Maximum allowable reinforcement if welded from two sides: 0.1875" Total of Wall + Reinforcement 0.625"

PENETRAMETER SELECTION FOR API 620, 650, & 653Welds without reinforcement: Same as aboveWelds with reinforcement: S/S Hole: 17 S/S Wire: 0.013 Esn. Wire: B5

F/S Hole: 15 F/S Wire: 0.010 Esn. Wire: A1 or B6

Maximum allowable reinforcement: 0.0625" Total of Wall + Reinforcement 0.500"

UW-51; API 620, 650, & 653Cracks, Incomplete Penetration, and Incomplete Fusion: None AllowedOther Elongated Indications (UW-51 only):Max Length of other elongated indications: 0.250"Max Cumulative length of aligned indications is 0.4375" in a length of weld equal to 5.250" unlessseperated by the length of 6L Rounded Indications (UW-51 Only):Relevant Indications: 0.031Max Size of Random Indications: 0.109" Max Size of Isolated Rounded Indications: 0.146"Max sum of diameters of Aligned Rounded Indications: 0.4375" in a 5.250" length of weldMax group length of Aligned Rounded Indications: 0.250"Max group length of Cluster Rounded Indications if 1 group is present in a 6" length of weld: 0.875"Max group length of Cluster Rounded Indications if more than 1 group is present in a 6" length of weld: 1.0"

UW-52Cracks, Incomplete Penetration, and Incomplete Fusion: None AllowedSlag Inclusions:Max Size of slag inclusions: 0.292"Max Cumulative length of acceptable in-line indications (other than rounded): 0.4375" in a 2.625" length ofwelds and must be seperated by the length of 3L of acceptable weld metal.

Technique Sheet Info (Source Side of Object to Film and Source Distances)Reinforcement is found in the applicable penetrameter selection boxes above.

Source to Source Side of Object; As measured in the field.Source Side of Object to Film Distance: 0.4375"

Page 299: NDT Code Book Made Easy

S

ASME SECTION VIII - PLATE ONLY

1/2" Plate - 0.500" Wall

PENETRAMETER SELECTIONNote: Esn. Wire: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Hole 17 S/S Wire: 0.013 Esn Wire: B5 F/S Hole: 15 F/S Wire: 0.010 Esn Wire: A1 or B6Reinforced welds welded fromone side: S/S Hole: 20 S/S Wire: 0.016 Esn. Wire: B4

F/S Hole: 17 S/S Wire: 0.013 Esn. Wire: B5Reinforced welds welded fromtwo sides: S/S Hole: 20 S/S Wire: 0.016 Esn. Wire: B4

F/S Hole: 17 S/S Wire: 0.013 Esn. Wire: B5

Maximum allowable reinforcement if welded from one side: 0.094" Total of Wall + Reinforcement 0.594"Maximum allowable reinforcement if welded from two sides: 0.1875" Total of Wall + Reinforcement 0.6875"

PENETRAMETER SELECTION FOR API 620, 650, & 653Welds without reinforcement: Same as aboveWelds with reinforcement: S/S Hole: 20 S/S Wire: 0.016 Esn. Wire: B4

F/S Hole: 17 F/S Wire: 0.013 Esn. Wire: B5

Maximum allowable reinforcement: 0.0625" Total of Wall + Reinforcement 0.563"

UW-51; API 620, 650, & 653Cracks, Incomplete Penetration, and Incomplete Fusion: None AllowedOther Elongated Indications (UW-51 only):Max Length of other elongated indications: 0.250"Max Cumulative length of aligned indications is 0.500" in a length of weld equal to 6.00" unlessseperated by the length of 6L Rounded Indications (UW-51 Only):Relevant Indications: 0.031Max Size of Random Indications: 0.125" Max Size of Isolated Rounded Indications: 0.167"Max sum of diameters of Aligned Rounded Indications: 0.500" in a 6.00" length of weldMax group length of Aligned Rounded Indications: 0.250"Max group length of Cluster Rounded Indications if 1 group is present in a 6" length of weld: 1.00"Max group length of Cluster Rounded Indications if more than 1 group is present in a 6" length of weld: 1.0"

UW-52Cracks, Incomplete Penetration, and Incomplete Fusion: None AllowedSlag Inclusions:Max Size of slag inclusions: 0.334"Max Cumulative length of acceptable in-line indications (other than rounded): 0.500" in a 3.00" length ofwelds and must be seperated by the length of 3L of acceptable weld metal.

Technique Sheet Info (Source Side of Object to Film and Source Distances)Reinforcement is found in the applicable penetrameter selection boxes above.

Source to Source Side of Object; As measured in the field.Source Side of Object to Film Distance: 0.500"

Page 300: NDT Code Book Made Easy

S

ASME SECTION VIII - PLATE ONLY

9/16" Plate - 0.5625" Wall

PENETRAMETER SELECTIONNote: Esn. Wire: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Hole 20 S/S Wire: 0.016 Esn Wire: B4 F/S Hole: 17 F/S Wire: 0.013 Esn Wire: B5Reinforced welds welded fromone side: S/S Hole: 20 S/S Wire: 0.016 Esn. Wire: B4

F/S Hole: 17 S/S Wire: 0.013 Esn. Wire: B5Reinforced welds welded fromtwo sides: S/S Hole: 20 S/S Wire: 0.016 Esn. Wire: B4

F/S Hole: 17 S/S Wire: 0.013 Esn. Wire: B5

Maximum allowable reinforcement if welded from one side: 0.094" Total of Wall + Reinforcement 0.657"Maximum allowable reinforcement if welded from two sides: 0.1875" Total of Wall + Reinforcement 0.750"

PENETRAMETER SELECTION FOR API 620, 650, & 653Welds without reinforcement: Same as aboveWelds with reinforcement: S/S Hole: 20 S/S Wire: 0.016 Esn. Wire: B4

F/S Hole: 17 F/S Wire: 0.013 Esn. Wire: B5

Maximum allowable reinforcement: 0.0625" Total of Wall + Reinforcement 0.657"

UW-51; API 620, 650, & 653Cracks, Incomplete Penetration, and Incomplete Fusion: None AllowedOther Elongated Indications (UW-51 only):Max Length of other elongated indications: 0.250"Max Cumulative length of aligned indications is 0.5625" in a length of weld equal to 6.750" unlessseperated by the length of 6L Rounded Indications (UW-51 Only):Relevant Indications: 0.031Max Size of Random Indications: 0.141" Max Size of Isolated Rounded Indications: 0.188"Max sum of diameters of Aligned Rounded Indications: 0.5625" in a 6.750" length of weldMax group length of Aligned Rounded Indications: 0.250"Max group length of Cluster Rounded Indications if 1 group is present in a 6" length of weld: 1.00"Max group length of Cluster Rounded Indications if more than 1 group is present in a 6" length of weld: 1.0"

UW-52Cracks, Incomplete Penetration, and Incomplete Fusion: None AllowedSlag Inclusions:Max Size of slag inclusions: 0.375"Max Cumulative length of acceptable in-line indications (other than rounded): 0.5625" in a 3.375" length ofwelds and must be seperated by the length of 3L of acceptable weld metal.

Technique Sheet Info (Source Side of Object to Film and Source Distances)Reinforcement is found in the applicable penetrameter selection boxes above.

Source to Source Side of Object; As measured in the field.Source Side of Object to Film Distance: 0.5625"

Page 301: NDT Code Book Made Easy

S

ASME SECTION VIII - PLATE ONLY

5/8" Plate - 0.625" Wall

PENETRAMETER SELECTIONNote: Esn. Wire: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Hole 20 S/S Wire: 0.016 Esn Wire: B4 F/S Hole: 17 F/S Wire: 0.013 Esn Wire: B5Reinforced welds welded fromone side: S/S Hole: 20 S/S Wire: 0.016 Esn. Wire: B4

F/S Hole: 17 S/S Wire: 0.013 Esn. Wire: B5Reinforced welds welded fromtwo sides: S/S Hole: 25 S/S Wire: 0.020 Esn. Wire: B3

F/S Hole: 20 S/S Wire: 0.016 Esn. Wire: B4

Maximum allowable reinforcement if welded from one side: 0.094" Total of Wall + Reinforcement 0.719"Maximum allowable reinforcement if welded from two sides: 0.1875" Total of Wall + Reinforcement 0.813"

PENETRAMETER SELECTION FOR API 620, 650, & 653Welds without reinforcement: Same as aboveWelds with reinforcement: S/S Hole: 20 S/S Wire: 0.016 Esn. Wire: B4

F/S Hole: 17 F/S Wire: 0.013 Esn. Wire: B5

Maximum allowable reinforcement: 0.094" Total of Wall + Reinforcement 0.719"

UW-51; API 620, 650, & 653Cracks, Incomplete Penetration, and Incomplete Fusion: None AllowedOther Elongated Indications (UW-51 only):Max Length of other elongated indications: 0.250"Max Cumulative length of aligned indications is 0.625" in a length of weld equal to 7.500" unlessseperated by the length of 6L Rounded Indications (UW-51 Only):Relevant Indications: 0.031Max Size of Random Indications: 0.156" Max Size of Isolated Rounded Indications: 0.208"Max sum of diameters of Aligned Rounded Indications: 0.625" in a 7.500" length of weldMax group length of Aligned Rounded Indications: 0.250"Max group length of Cluster Rounded Indications if 1 group is present in a 6" length of weld: 1.00"Max group length of Cluster Rounded Indications if more than 1 group is present in a 6" length of weld: 1.0"

UW-52Cracks, Incomplete Penetration, and Incomplete Fusion: None AllowedSlag Inclusions:Max Size of slag inclusions: 0.417"Max Cumulative length of acceptable in-line indications (other than rounded): 0.625" in a 3.75" length ofwelds and must be seperated by the length of 3L of acceptable weld metal.

Technique Sheet Info (Source Side of Object to Film and Source Distances)Reinforcement is found in the applicable penetrameter selection boxes above.

Source to Source Side of Object; As measured in the field.Source Side of Object to Film Distance: 0.625"

Page 302: NDT Code Book Made Easy

S

ASME SECTION VIII - PLATE ONLY

11/16" Plate - 0.6875" Wall

PENETRAMETER SELECTIONNote: Esn. Wire: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Hole 20 S/S Wire: 0.016 Esn Wire: B4 F/S Hole: 17 F/S Wire: 0.013 Esn Wire: B5Reinforced welds welded fromone side: S/S Hole: 25 S/S Wire: 0.020 Esn. Wire: B3

F/S Hole: 20 S/S Wire: 0.016 Esn. Wire: B4Reinforced welds welded fromtwo sides: S/S Hole: 25 S/S Wire: 0.020 Esn. Wire: B3

F/S Hole: 20 S/S Wire: 0.016 Esn. Wire: B4

Maximum allowable reinforcement if welded from one side: 0.094" Total of Wall + Reinforcement 0.782"Maximum allowable reinforcement if welded from two sides: 0.1875" Total of Wall + Reinforcement 0.875"

PENETRAMETER SELECTION FOR API 620, 650, & 653Welds without reinforcement: Same as aboveWelds with reinforcement: S/S Hole: 25 S/S Wire: 0.020 Esn. Wire: B3

F/S Hole: 20 F/S Wire: 0.016 Esn. Wire: B4

Maximum allowable reinforcement: 0.094" Total of Wall + Reinforcement 0.782"

UW-51; API 620, 650, & 653Cracks, Incomplete Penetration, and Incomplete Fusion: None AllowedOther Elongated Indications (UW-51 only):Max Length of other elongated indications: 0.250"Max Cumulative length of aligned indications is 0.6875" in a length of weld equal to 8.250" unlessseperated by the length of 6L Rounded Indications (UW-51 Only):Relevant Indications: 0.031Max Size of Random Indications: 0.156" Max Size of Isolated Rounded Indications: 0.229"Max sum of diameters of Aligned Rounded Indications: 0.6875" in a 8.250" length of weldMax group length of Aligned Rounded Indications: 0.250"Max group length of Cluster Rounded Indications if 1 group is present in a 6" length of weld: 1.00"Max group length of Cluster Rounded Indications if more than 1 group is present in a 6" length of weld: 1.0"

UW-52Cracks, Incomplete Penetration, and Incomplete Fusion: None AllowedSlag Inclusions:Max Size of slag inclusions: 0.459"Max Cumulative length of acceptable in-line indications (other than rounded): 0.6875" in a 4.125" length ofwelds and must be seperated by the length of 3L of acceptable weld metal.

Technique Sheet Info (Source Side of Object to Film and Source Distances)Reinforcement is found in the applicable penetrameter selection boxes above.

Source to Source Side of Object; As measured in the field.Source Side of Object to Film Distance: 0.6875"

Page 303: NDT Code Book Made Easy

S

ASME SECTION VIII - PLATE ONLY

3/4" Plate - 0.750" Wall

PENETRAMETER SELECTIONNote: Esn. Wire: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Hole 20 S/S Wire: 0.016 Esn Wire: B4 F/S Hole: 17 F/S Wire: 0.013 Esn Wire: B5Reinforced welds welded fromone side: S/S Hole: 25 S/S Wire: 0.020 Esn. Wire: B3

F/S Hole: 20 S/S Wire: 0.016 Esn. Wire: B4Reinforced welds welded fromtwo sides: S/S Hole: 25 S/S Wire: 0.020 Esn. Wire: B3

F/S Hole: 20 S/S Wire: 0.016 Esn. Wire: B4

Maximum allowable reinforcement if welded from one side: 0.094" Total of Wall + Reinforcement 0.844"Maximum allowable reinforcement if welded from two sides: 0.1875" Total of Wall + Reinforcement 0.938"

PENETRAMETER SELECTION FOR API 620, 650, & 653Welds without reinforcement: Same as aboveWelds with reinforcement: S/S Hole: 25 S/S Wire: 0.020 Esn. Wire: B3

F/S Hole: 20 F/S Wire: 0.016 Esn. Wire: B4

Maximum allowable reinforcement: 0.094" Total of Wall + Reinforcement 0.844"

UW-51; API 620, 650, & 653Cracks, Incomplete Penetration, and Incomplete Fusion: None AllowedOther Elongated Indications (UW-51 only):Max Length of other elongated indications: 0.250"Max Cumulative length of aligned indications is 0.750" in a length of weld equal to 9.00" unlessseperated by the length of 6L Rounded Indications (UW-51 Only):Relevant Indications: 0.031Max Size of Random Indications: 0.156" Max Size of Isolated Rounded Indications: 0.250"Max sum of diameters of Aligned Rounded Indications: 0.750" in a 9.00" length of weldMax group length of Aligned Rounded Indications: 0.250"Max group length of Cluster Rounded Indications if 1 group is present in a 6" length of weld: 1.00"Max group length of Cluster Rounded Indications if more than 1 group is present in a 6" length of weld: 1.0"

UW-52Cracks, Incomplete Penetration, and Incomplete Fusion: None AllowedSlag Inclusions:Max Size of slag inclusions: 0.500"Max Cumulative length of acceptable in-line indications (other than rounded): 0.750" in a 4.500" length ofwelds and must be seperated by the length of 3L of acceptable weld metal.

Technique Sheet Info (Source Side of Object to Film and Source Distances)Reinforcement is found in the applicable penetrameter selection boxes above.

Source to Source Side of Object; As measured in the field.Source Side of Object to Film Distance: 0.750"

Page 304: NDT Code Book Made Easy

S

ASME SECTION VIII - PLATE ONLY

13/16" Plate - 0.8125" Wall

PENETRAMETER SELECTIONNote: Esn. Wire: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Hole 25 S/S Wire: 0.020 Esn Wire: B3 F/S Hole: 20 F/S Wire: 0.016 Esn Wire: B4Reinforced welds welded fromone side: S/S Hole: 25 S/S Wire: 0.020 Esn. Wire: B3

F/S Hole: 20 S/S Wire: 0.016 Esn. Wire: B4Reinforced welds welded fromtwo sides: S/S Hole: 25 S/S Wire: 0.020 Esn. Wire: B3

F/S Hole: 20 S/S Wire: 0.016 Esn. Wire: B4

Maximum allowable reinforcement if welded from one side: 0.094" Total of Wall + Reinforcement 0.907"Maximum allowable reinforcement if welded from two sides: 0.1875" Total of Wall + Reinforcement 1.00"

PENETRAMETER SELECTION FOR API 620, 650, & 653Welds without reinforcement: Same as aboveWelds with reinforcement: S/S Hole: 25 S/S Wire: 0.020 Esn. Wire: B3

F/S Hole: 20 F/S Wire: 0.016 Esn. Wire: B4

Maximum allowable reinforcement: 0.094" Total of Wall + Reinforcement 0.907"

UW-51; API 620, 650, & 653Cracks, Incomplete Penetration, and Incomplete Fusion: None AllowedOther Elongated Indications (UW-51 only):Max Length of other elongated indications: 0.271"Max Cumulative length of aligned indications is 0.8125" in a length of weld equal to 9.750" unlessseperated by the length of 6L Rounded Indications (UW-51 Only):Relevant Indications: 0.031Max Size of Random Indications: 0.156" Max Size of Isolated Rounded Indications: 0.250"Max sum of diameters of Aligned Rounded Indications: 0.8125" in a 9.750" length of weldMax group length of Aligned Rounded Indications: 0.271"Max group length of Cluster Rounded Indications if 1 group is present in a 6" length of weld: 1.00"Max group length of Cluster Rounded Indications if more than 1 group is present in a 6" length of weld: 1.0"

UW-52Cracks, Incomplete Penetration, and Incomplete Fusion: None AllowedSlag Inclusions:Max Size of slag inclusions: 0.542"Max Cumulative length of acceptable in-line indications (other than rounded): 0.8125" in a 4.875" length ofwelds and must be seperated by the length of 3L of acceptable weld metal.

Technique Sheet Info (Source Side of Object to Film and Source Distances)Reinforcement is found in the applicable penetrameter selection boxes above.

Source to Source Side of Object; As measured in the field.Source Side of Object to Film Distance: 0.8125"

Page 305: NDT Code Book Made Easy

S

ASME SECTION VIII - PLATE ONLY

7/8" Plate - 0.875" Wall

PENETRAMETER SELECTIONNote: Esn. Wire: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Hole 25 S/S Wire: 0.020 Esn Wire: B3 F/S Hole: 20 F/S Wire: 0.016 Esn Wire: B4Reinforced welds welded fromone side: S/S Hole: 25 S/S Wire: 0.020 Esn. Wire: B3

F/S Hole: 20 S/S Wire: 0.016 Esn. Wire: B4Reinforced welds welded fromtwo sides: S/S Hole: 30 S/S Wire: 0.025 Esn. Wire: B2

F/S Hole: 25 S/S Wire: 0.020 Esn. Wire: B3

Maximum allowable reinforcement if welded from one side: 0.094" Total of Wall + Reinforcement 0.969"Maximum allowable reinforcement if welded from two sides: 0.1875" Total of Wall + Reinforcement 1.063"

PENETRAMETER SELECTION FOR API 620, 650, & 653Welds without reinforcement: Same as aboveWelds with reinforcement: S/S Hole: 25 S/S Wire: 0.020 Esn. Wire: B3

F/S Hole: 20 F/S Wire: 0.016 Esn. Wire: B4

Maximum allowable reinforcement: 0.094" Total of Wall + Reinforcement 0.969"

UW-51; API 620, 650, & 653Cracks, Incomplete Penetration, and Incomplete Fusion: None AllowedOther Elongated Indications (UW-51 only):Max Length of other elongated indications: 0.292"Max Cumulative length of aligned indications is 0.875" in a length of weld equal to 10.500" unlessseperated by the length of 6L Rounded Indications (UW-51 Only):Relevant Indications: 0.031Max Size of Random Indications: 0.156" Max Size of Isolated Rounded Indications: 0.250"Max sum of diameters of Aligned Rounded Indications: 0.875" in a 10.500" length of weldMax group length of Aligned Rounded Indications: 0.292"Max group length of Cluster Rounded Indications if 1 group is present in a 6" length of weld: 1.00"Max group length of Cluster Rounded Indications if more than 1 group is present in a 6" length of weld: 1.0"

UW-52Cracks, Incomplete Penetration, and Incomplete Fusion: None AllowedSlag Inclusions:Max Size of slag inclusions: 0.584"Max Cumulative length of acceptable in-line indications (other than rounded): 0.875" in a 5.25" length ofwelds and must be seperated by the length of 3L of acceptable weld metal.

Technique Sheet Info (Source Side of Object to Film and Source Distances)Reinforcement is found in the applicable penetrameter selection boxes above.

Source to Source Side of Object; As measured in the field.Source Side of Object to Film Distance: 0.875"

Page 306: NDT Code Book Made Easy

S

ASME SECTION VIII - PLATE ONLY

15/16" Plate - 0.9375" Wall

PENETRAMETER SELECTIONNote: Esn. Wire: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Hole 25 S/S Wire: 0.020 Esn Wire: B3 F/S Hole: 20 F/S Wire: 0.016 Esn Wire: B4Reinforced welds welded fromone side: S/S Hole: 30 S/S Wire: 0.025 Esn. Wire: B2

F/S Hole: 25 S/S Wire: 0.020 Esn. Wire: B3Reinforced welds welded fromtwo sides: S/S Hole: 30 S/S Wire: 0.025 Esn. Wire: B2

F/S Hole: 25 S/S Wire: 0.020 Esn. Wire: B3

Maximum allowable reinforcement if welded from one side: 0.094" Total of Wall + Reinforcement 1.032"Maximum allowable reinforcement if welded from two sides: 0.1875" Total of Wall + Reinforcement 1.125"

PENETRAMETER SELECTION FOR API 620, 650, & 653Welds without reinforcement: Same as aboveWelds with reinforcement: S/S Hole: 30 S/S Wire: 0.025 Esn. Wire: B2

F/S Hole: 25 F/S Wire: 0.020 Esn. Wire: B3

Maximum allowable reinforcement: 0.094" Total of Wall + Reinforcement 1.032"

UW-51; API 620, 650, & 653Cracks, Incomplete Penetration, and Incomplete Fusion: None AllowedOther Elongated Indications (UW-51 only):Max Length of other elongated indications: 0.313"Max Cumulative length of aligned indications is 0.9375" in a length of weld equal to 11.250" unlessseperated by the length of 6L Rounded Indications (UW-51 Only):Relevant Indications: 0.031Max Size of Random Indications: 0.156" Max Size of Isolated Rounded Indications: 0.250"Max sum of diameters of Aligned Rounded Indications: 0.9375" in a 11.250" length of weldMax group length of Aligned Rounded Indications: 0.313"Max group length of Cluster Rounded Indications if 1 group is present in a 6" length of weld: 1.00"Max group length of Cluster Rounded Indications if more than 1 group is present in a 6" length of weld: 1.0"

UW-52Cracks, Incomplete Penetration, and Incomplete Fusion: None AllowedSlag Inclusions:Max Size of slag inclusions: 0.625"Max Cumulative length of acceptable in-line indications (other than rounded): 0.9375" in a 5.625" length ofwelds and must be seperated by the length of 3L of acceptable weld metal.

Technique Sheet Info (Source Side of Object to Film and Source Distances)Reinforcement is found in the applicable penetrameter selection boxes above.

Source to Source Side of Object; As measured in the field.Source Side of Object to Film Distance: 0.9375"

Page 307: NDT Code Book Made Easy

S

ASME SECTION VIII - PLATE ONLY

1" Plate - 1.00" Wall

PENETRAMETER SELECTIONNote: Esn. Wire: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Hole 25 S/S Wire: 0.020 Esn Wire: B3 F/S Hole: 20 F/S Wire: 0.016 Esn Wire: B4Reinforced welds welded fromone side: S/S Hole: 30 S/S Wire: 0.025 Esn. Wire: B2

F/S Hole: 25 S/S Wire: 0.020 Esn. Wire: B3Reinforced welds welded fromtwo sides: S/S Hole: 30 S/S Wire: 0.025 Esn. Wire: B2

F/S Hole: 25 S/S Wire: 0.020 Esn. Wire: B3

Maximum allowable reinforcement if welded from one side: 0.094" Total of Wall + Reinforcement 1.094"Maximum allowable reinforcement if welded from two sides: 0.1875" Total of Wall + Reinforcement 1.1875"

PENETRAMETER SELECTION FOR API 620, 650, & 653Welds without reinforcement: Same as aboveWelds with reinforcement: S/S Hole: 30 S/S Wire: 0.025 Esn. Wire: B2

F/S Hole: 25 F/S Wire: 0.020 Esn. Wire: B3

Maximum allowable reinforcement: 0.094" Total of Wall + Reinforcement 1.094"

UW-51; API 620, 650, & 653Cracks, Incomplete Penetration, and Incomplete Fusion: None AllowedOther Elongated Indications (UW-51 only):Max Length of other elongated indications: 0.333"Max Cumulative length of aligned indications is 1.00" in a length of weld equal to 12.00" unlessseperated by the length of 6L Rounded Indications (UW-51 Only):Relevant Indications: 0.031Max Size of Random Indications: 0.156" Max Size of Isolated Rounded Indications: 0.250"Max sum of diameters of Aligned Rounded Indications: 1.00" in a 12.00" length of weldMax group length of Aligned Rounded Indications: 0.333"Max group length of Cluster Rounded Indications if 1 group is present in a 6" length of weld: 1.00"Max group length of Cluster Rounded Indications if more than 1 group is present in a 6" length of weld: 1.0"

UW-52Cracks, Incomplete Penetration, and Incomplete Fusion: None AllowedSlag Inclusions:Max Size of slag inclusions: 0.667"Max Cumulative length of acceptable in-line indications (other than rounded): 1.00" in a 6.00" length ofwelds and must be seperated by the length of 3L of acceptable weld metal.

Technique Sheet Info (Source Side of Object to Film and Source Distances)Reinforcement is found in the applicable penetrameter selection boxes above.

Source to Source Side of Object; As measured in the field.Source Side of Object to Film Distance: 1.00"

Page 308: NDT Code Book Made Easy

S

ASME SECTION VIII - PLATE ONLY

1 1/16" Plate - 1.0625" Wall

PENETRAMETER SELECTIONNote: Esn. Wire: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Hole 30 S/S Wire: 0.025 Esn Wire: B2 F/S Hole: 25 F/S Wire: 0.020 Esn Wire: B3Reinforced welds welded fromone side: S/S Hole: 30 S/S Wire: 0.025 Esn. Wire: B2

F/S Hole: 25 S/S Wire: 0.020 Esn. Wire: B3Reinforced welds welded fromtwo sides: S/S Hole: 30 S/S Wire: 0.025 Esn. Wire: B2

F/S Hole: 25 S/S Wire: 0.020 Esn. Wire: B3

Maximum allowable reinforcement if welded from one side: 0.125" Total of Wall + Reinforcement 1.188"Maximum allowable reinforcement if welded from two sides: 0.250" Total of Wall + Reinforcement 1.313"

PENETRAMETER SELECTION FOR API 620, 650, & 653Welds without reinforcement: Same as aboveWelds with reinforcement: S/S Hole: 30 S/S Wire: 0.025 Esn. Wire: B2

F/S Hole: 25 F/S Wire: 0.020 Esn. Wire: B3

Maximum allowable reinforcement: 0.125" Total of Wall + Reinforcement 1.188"

UW-51; API 620, 650, & 653Cracks, Incomplete Penetration, and Incomplete Fusion: None AllowedOther Elongated Indications (UW-51 only):Max Length of other elongated indications: 0.354"Max Cumulative length of aligned indications is 1.0625" in a length of weld equal to 12.75" unlessseperated by the length of 6L Rounded Indications (UW-51 Only):Relevant Indications: 0.031Max Size of Random Indications: 0.156" Max Size of Isolated Rounded Indications: 0.250"Max sum of diameters of Aligned Rounded Indications: 1.0625" in a 12.75" length of weldMax group length of Aligned Rounded Indications: 0.354"Max group length of Cluster Rounded Indications if 1 group is present in a 6" length of weld: 1.00"Max group length of Cluster Rounded Indications if more than 1 group is present in a 6" length of weld: 1.0"

UW-52Cracks, Incomplete Penetration, and Incomplete Fusion: None AllowedSlag Inclusions:Max Size of slag inclusions: 0.709"Max Cumulative length of acceptable in-line indications (other than rounded): 1.0625" in a 6.375" length ofwelds and must be seperated by the length of 3L of acceptable weld metal.

Technique Sheet Info (Source Side of Object to Film and Source Distances)Reinforcement is found in the applicable penetrameter selection boxes above.

Source to Source Side of Object; As measured in the field.Source Side of Object to Film Distance: 1.0625"

Page 309: NDT Code Book Made Easy

S

ASME SECTION VIII - PLATE ONLY

1 1/8" Plate - 1.125" Wall

PENETRAMETER SELECTIONNote: Esn. Wire: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Hole 30 S/S Wire: 0.025 Esn Wire: B2 F/S Hole: 25 F/S Wire: 0.020 Esn Wire: B3Reinforced welds welded fromone side: S/S Hole: 30 S/S Wire: 0.025 Esn. Wire: B2

F/S Hole: 25 S/S Wire: 0.020 Esn. Wire: B3Reinforced welds welded fromtwo sides: S/S Hole: 30 S/S Wire: 0.025 Esn. Wire: B2

F/S Hole: 25 S/S Wire: 0.020 Esn. Wire: B3

Maximum allowable reinforcement if welded from one side: 0.125" Total of Wall + Reinforcement 1.250"Maximum allowable reinforcement if welded from two sides: 0.250" Total of Wall + Reinforcement 1.375"

PENETRAMETER SELECTION FOR API 620, 650, & 653Welds without reinforcement: Same as aboveWelds with reinforcement: S/S Hole: 30 S/S Wire: 0.025 Esn. Wire: B2

F/S Hole: 25 F/S Wire: 0.020 Esn. Wire: B3

Maximum allowable reinforcement: 0.125" Total of Wall + Reinforcement 1.250"

UW-51; API 620, 650, & 653Cracks, Incomplete Penetration, and Incomplete Fusion: None AllowedOther Elongated Indications (UW-51 only):Max Length of other elongated indications: 0.375"Max Cumulative length of aligned indications is 1.125" in a length of weld equal to 13.500" unlessseperated by the length of 6L Rounded Indications (UW-51 Only):Relevant Indications: 0.031Max Size of Random Indications: 0.156" Max Size of Isolated Rounded Indications: 0.250"Max sum of diameters of Aligned Rounded Indications: 1.125" in a 13.5 length of weldMax group length of Aligned Rounded Indications: 0.375"Max group length of Cluster Rounded Indications if 1 group is present in a 6" length of weld: 1.00"Max group length of Cluster Rounded Indications if more than 1 group is present in a 6" length of weld: 1.0"

UW-52Cracks, Incomplete Penetration, and Incomplete Fusion: None AllowedSlag Inclusions:Max Size of slag inclusions: 0.750"Max Cumulative length of acceptable in-line indications (other than rounded): 1.125" in a 6.750" length ofwelds and must be seperated by the length of 3L of acceptable weld metal.

Technique Sheet Info (Source Side of Object to Film and Source Distances)Reinforcement is found in the applicable penetrameter selection boxes above.

Source to Source Side of Object; As measured in the field.Source Side of Object to Film Distance: 1.125"

Page 310: NDT Code Book Made Easy

S

ASME SECTION VIII - PLATE ONLY

1 3/16" Plate - 1.1875" Wall

PENETRAMETER SELECTIONNote: Esn. Wire: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Hole 30 S/S Wire: 0.025 Esn Wire: B2 F/S Hole: 25 F/S Wire: 0.020 Esn Wire: B3Reinforced welds welded fromone side: S/S Hole: 30 S/S Wire: 0.025 Esn. Wire: B2

F/S Hole: 25 S/S Wire: 0.020 Esn. Wire: B3Reinforced welds welded fromtwo sides: S/S Hole: 30 S/S Wire: 0.025 Esn. Wire: B2

F/S Hole: 25 S/S Wire: 0.020 Esn. Wire: B3

Maximum allowable reinforcement if welded from one side: 0.125" Total of Wall + Reinforcement 1.313"Maximum allowable reinforcement if welded from two sides: 0.250" Total of Wall + Reinforcement 1.438"

PENETRAMETER SELECTION FOR API 620, 650, & 653Welds without reinforcement: Same as aboveWelds with reinforcement: S/S Hole: 30 S/S Wire: 0.025 Esn. Wire: B2

F/S Hole: 25 F/S Wire: 0.020 Esn. Wire: B3

Maximum allowable reinforcement: 0.125" Total of Wall + Reinforcement 1.313"

UW-51; API 620, 650, & 653Cracks, Incomplete Penetration, and Incomplete Fusion: None AllowedOther Elongated Indications (UW-51 only):Max Length of other elongated indications: 0.396"Max Cumulative length of aligned indications is 1.1875" in a length of weld equal to 14.250" unlessseperated by the length of 6L Rounded Indications (UW-51 Only):Relevant Indications: 0.031Max Size of Random Indications: 0.156" Max Size of Isolated Rounded Indications: 0.250"Max sum of diameters of Aligned Rounded Indications: 1.1875" in a 14.250" length of weldMax group length of Aligned Rounded Indications: 0.396"Max group length of Cluster Rounded Indications if 1 group is present in a 6" length of weld: 1.00"Max group length of Cluster Rounded Indications if more than 1 group is present in a 6" length of weld: 1.0"

UW-52Cracks, Incomplete Penetration, and Incomplete Fusion: None AllowedSlag Inclusions:Max Size of slag inclusions: 0.750"Max Cumulative length of acceptable in-line indications (other than rounded): 1.1875" in a 7.125" length ofwelds and must be seperated by the length of 3L of acceptable weld metal.

Technique Sheet Info (Source Side of Object to Film and Source Distances)Reinforcement is found in the applicable penetrameter selection boxes above.

Source to Source Side of Object; As measured in the field.Source Side of Object to Film Distance: 1.1875"

Page 311: NDT Code Book Made Easy

S

ASME SECTION VIII - PLATE ONLY

1 1/4" Plate - 1.250" Wall

PENETRAMETER SELECTIONNote: Esn. Wire: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Hole 30 S/S Wire: 0.025 Esn Wire: B2 F/S Hole: 25 F/S Wire: 0.020 Esn Wire: B3Reinforced welds welded fromone side: S/S Hole: 30 S/S Wire: 0.025 Esn. Wire: B2

F/S Hole: 25 S/S Wire: 0.020 Esn. Wire: B3Reinforced welds welded fromtwo sides: S/S Hole: 30 S/S Wire: 0.025 Esn. Wire: B2

F/S Hole: 25 S/S Wire: 0.020 Esn. Wire: B3

Maximum allowable reinforcement if welded from one side: 0.125" Total of Wall + Reinforcement 1.375"Maximum allowable reinforcement if welded from two sides: 0.250" Total of Wall + Reinforcement 1.500"

PENETRAMETER SELECTION FOR API 620, 650, & 653Welds without reinforcement: Same as aboveWelds with reinforcement: S/S Hole: 30 S/S Wire: 0.025 Esn. Wire: B2

F/S Hole: 25 F/S Wire: 0.020 Esn. Wire: B3

Maximum allowable reinforcement: 0.125" Total of Wall + Reinforcement 1.375"

UW-51; API 620, 650, & 653Cracks, Incomplete Penetration, and Incomplete Fusion: None AllowedOther Elongated Indications (UW-51 only):Max Length of other elongated indications: 0.417"Max Cumulative length of aligned indications is 1.250" in a length of weld equal to 15.0" unlessseperated by the length of 6L Rounded Indications (UW-51 Only):Relevant Indications: 0.031Max Size of Random Indications: 0.156" Max Size of Isolated Rounded Indications: 0.250"Max sum of diameters of Aligned Rounded Indications: 1.250" in a 15.0" length of weldMax group length of Aligned Rounded Indications: 0.417"Max group length of Cluster Rounded Indications if 1 group is present in a 6" length of weld: 1.00"Max group length of Cluster Rounded Indications if more than 1 group is present in a 6" length of weld: 1.0"

UW-52Cracks, Incomplete Penetration, and Incomplete Fusion: None AllowedSlag Inclusions:Max Size of slag inclusions: 0.750"Max Cumulative length of acceptable in-line indications (other than rounded): 1.250" in a 7.500" length ofwelds and must be seperated by the length of 3L of acceptable weld metal.

Technique Sheet Info (Source Side of Object to Film and Source Distances)Reinforcement is found in the applicable penetrameter selection boxes above.

Source to Source Side of Object; As measured in the field.Source Side of Object to Film Distance: 1.250"

Page 312: NDT Code Book Made Easy

S

ASME SECTION VIII - PLATE ONLY

1 5/16" Plate - 1.3125" Wall

PENETRAMETER SELECTIONNote: Esn. Wire: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Hole 30 S/S Wire: 0.025 Esn Wire: B2 F/S Hole: 25 F/S Wire: 0.020 Esn Wire: B3Reinforced welds welded fromone side: S/S Hole: 30 S/S Wire: 0.025 Esn. Wire: B2

F/S Hole: 25 S/S Wire: 0.020 Esn. Wire: B3Reinforced welds welded fromtwo sides: S/S Hole: 30 S/S Wire: 0.025 Esn. Wire: B2

F/S Hole: 25 S/S Wire: 0.020 Esn. Wire: B3

Maximum allowable reinforcement if welded from one side: 0.125" Total of Wall + Reinforcement 1.438"Maximum allowable reinforcement if welded from two sides: 0.250" Total of Wall + Reinforcement 1.5625"

PENETRAMETER SELECTION FOR API 620, 650, & 653Welds without reinforcement: Same as aboveWelds with reinforcement: S/S Hole: 30 S/S Wire: 0.025 Esn. Wire: B2

F/S Hole: 25 F/S Wire: 0.020 Esn. Wire: B3

Maximum allowable reinforcement: 0.125" Total of Wall + Reinforcement 1.438"

UW-51; API 620, 650, & 653Cracks, Incomplete Penetration, and Incomplete Fusion: None AllowedOther Elongated Indications (UW-51 only):Max Length of other elongated indications: 0.438"Max Cumulative length of aligned indications is 1.3125" in a length of weld equal to 15.75" unlessseperated by the length of 6L Rounded Indications (UW-51 Only):Relevant Indications: 0.031Max Size of Random Indications: 0.156" Max Size of Isolated Rounded Indications: 0.250"Max sum of diameters of Aligned Rounded Indications: 1.3125" in a 15.75" length of weldMax group length of Aligned Rounded Indications: 0.438"Max group length of Cluster Rounded Indications if 1 group is present in a 6" length of weld: 1.00"Max group length of Cluster Rounded Indications if more than 1 group is present in a 6" length of weld: 1.0"

UW-52Cracks, Incomplete Penetration, and Incomplete Fusion: None AllowedSlag Inclusions:Max Size of slag inclusions: 0.750"Max Cumulative length of acceptable in-line indications (other than rounded): 1.3125" in a 7.875" length ofwelds and must be seperated by the length of 3L of acceptable weld metal.

Technique Sheet Info (Source Side of Object to Film and Source Distances)Reinforcement is found in the applicable penetrameter selection boxes above.

Source to Source Side of Object; As measured in the field.Source Side of Object to Film Distance: 1.3125"

Page 313: NDT Code Book Made Easy

S

ASME SECTION VIII - PLATE ONLY

1 3/8" Plate - 1.375" Wall

PENETRAMETER SELECTIONNote: Esn. Wire: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Hole 30 S/S Wire: 0.025 Esn Wire: B2 F/S Hole: 25 F/S Wire: 0.020 Esn Wire: B3Reinforced welds welded fromone side: S/S Hole: 30 S/S Wire: 0.025 Esn. Wire: B2

F/S Hole: 25 S/S Wire: 0.020 Esn. Wire: B3Reinforced welds welded fromtwo sides: S/S Hole: 35 S/S Wire: 0.032 Esn. Wire: B1 or C6

F/S Hole: 30 S/S Wire: 0.025 Esn. Wire: B2

Maximum allowable reinforcement if welded from one side: 0.125" Total of Wall + Reinforcement 1.500"Maximum allowable reinforcement if welded from two sides: 0.250" Total of Wall + Reinforcement 1.625"

PENETRAMETER SELECTION FOR API 620, 650, & 653Welds without reinforcement: Same as aboveWelds with reinforcement: S/S Hole: 30 S/S Wire: 0.025 Esn. Wire: B2

F/S Hole: 25 F/S Wire: 0.020 Esn. Wire: B3

Maximum allowable reinforcement: 0.125" Total of Wall + Reinforcement 1.500"

UW-51; API 620, 650, & 653Cracks, Incomplete Penetration, and Incomplete Fusion: None AllowedOther Elongated Indications (UW-51 only):Max Length of other elongated indications: 0.458"Max Cumulative length of aligned indications is 1.375" in a length of weld equal to 16.500" unlessseperated by the length of 6L Rounded Indications (UW-51 Only):Relevant Indications: 0.031Max Size of Random Indications: 0.156" Max Size of Isolated Rounded Indications: 0.250"Max sum of diameters of Aligned Rounded Indications: 1.375" in a 16.500" length of weldMax group length of Aligned Rounded Indications: 0.458"Max group length of Cluster Rounded Indications if 1 group is present in a 6" length of weld: 1.00"Max group length of Cluster Rounded Indications if more than 1 group is present in a 6" length of weld: 1.0"

UW-52Cracks, Incomplete Penetration, and Incomplete Fusion: None AllowedSlag Inclusions:Max Size of slag inclusions: 0.750"Max Cumulative length of acceptable in-line indications (other than rounded): 1.375" in a 8.250" length ofwelds and must be seperated by the length of 3L of acceptable weld metal.

Technique Sheet Info (Source Side of Object to Film and Source Distances)Reinforcement is found in the applicable penetrameter selection boxes above.

Source to Source Side of Object; As measured in the field.Source Side of Object to Film Distance: 1.375"

Page 314: NDT Code Book Made Easy

S

ASME SECTION VIII - PLATE ONLY

1 7/16" Plate - 1.4375" Wall

PENETRAMETER SELECTIONNote: Esn. Wire: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Hole 30 S/S Wire: 0.025 Esn Wire: B2 F/S Hole: 25 F/S Wire: 0.020 Esn Wire: B3Reinforced welds welded fromone side: S/S Hole: 35 S/S Wire: 0.032 Esn. Wire: B1 or C6

F/S Hole: 30 S/S Wire: 0.025 Esn. Wire: B2Reinforced welds welded fromtwo sides: S/S Hole: 35 S/S Wire: 0.032 Esn. Wire: B1 or C6

F/S Hole: 30 S/S Wire: 0.025 Esn. Wire: B2

Maximum allowable reinforcement if welded from one side: 0.125" Total of Wall + Reinforcement 1.563"Maximum allowable reinforcement if welded from two sides: 0.250" Total of Wall + Reinforcement 1.688"

PENETRAMETER SELECTION FOR API 620, 650, & 653Welds without reinforcement: Same as aboveWelds with reinforcement: S/S Hole: 35 S/S Wire: 0.032 Esn. Wire: B1 or C6

F/S Hole: 30 F/S Wire: 0.025 Esn. Wire: B2

Maximum allowable reinforcement: 0.125" Total of Wall + Reinforcement 1.563"

UW-51; API 620, 650, & 653Cracks, Incomplete Penetration, and Incomplete Fusion: None AllowedOther Elongated Indications (UW-51 only):Max Length of other elongated indications: 0.479"Max Cumulative length of aligned indications is 1.4375" in a length of weld equal to 17.250" unlessseperated by the length of 6L Rounded Indications (UW-51 Only):Relevant Indications: 0.031Max Size of Random Indications: 0.156" Max Size of Isolated Rounded Indications: 0.250"Max sum of diameters of Aligned Rounded Indications: 1.4375" in a 17.250" length of weldMax group length of Aligned Rounded Indications: 0.479"Max group length of Cluster Rounded Indications if 1 group is present in a 6" length of weld: 1.00"Max group length of Cluster Rounded Indications if more than 1 group is present in a 6" length of weld: 1.0"

UW-52Cracks, Incomplete Penetration, and Incomplete Fusion: None AllowedSlag Inclusions:Max Size of slag inclusions: 0.750"Max Cumulative length of acceptable in-line indications (other than rounded): 1.4375" in a 8.625" length ofwelds and must be seperated by the length of 3L of acceptable weld metal.

Technique Sheet Info (Source Side of Object to Film and Source Distances)Reinforcement is found in the applicable penetrameter selection boxes above.

Source to Source Side of Object; As measured in the field.Source Side of Object to Film Distance: 1.4375"

Page 315: NDT Code Book Made Easy

S

ASME SECTION VIII - PLATE ONLY

1 1/2" Plate - 1.500" Wall

PENETRAMETER SELECTIONNote: Esn. Wire: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Hole 30 S/S Wire: 0.025 Esn Wire: B2 F/S Hole: 25 F/S Wire: 0.020 Esn Wire: B3Reinforced welds welded fromone side: S/S Hole: 35 S/S Wire: 0.032 Esn. Wire: B1 or C6

F/S Hole: 30 S/S Wire: 0.025 Esn. Wire: B2Reinforced welds welded fromtwo sides: S/S Hole: 35 S/S Wire: 0.032 Esn. Wire: B1 or C6

F/S Hole: 30 S/S Wire: 0.025 Esn. Wire: B2

Maximum allowable reinforcement if welded from one side: 0.125" Total of Wall + Reinforcement 1.625"Maximum allowable reinforcement if welded from two sides: 0.250" Total of Wall + Reinforcement 1.750"

PENETRAMETER SELECTION FOR API 620, 650, & 653Welds without reinforcement: Same as aboveWelds with reinforcement: S/S Hole: 35 S/S Wire: 0.032 Esn. Wire: B1 or C6

F/S Hole: 30 F/S Wire: 0.025 Esn. Wire: B2

Maximum allowable reinforcement: 0.125" Total of Wall + Reinforcement 1.625"

UW-51; API 620, 650, & 653Cracks, Incomplete Penetration, and Incomplete Fusion: None AllowedOther Elongated Indications (UW-51 only):Max Length of other elongated indications: 0.500"Max Cumulative length of aligned indications is 1.500" in a length of weld equal to 18.0" unlessseperated by the length of 6L Rounded Indications (UW-51 Only):Relevant Indications: 0.031Max Size of Random Indications: 0.156" Max Size of Isolated Rounded Indications: 0.250"Max sum of diameters of Aligned Rounded Indications: 1.500" in a 18.0" length of weldMax group length of Aligned Rounded Indications: 0.500"Max group length of Cluster Rounded Indications if 1 group is present in a 6" length of weld: 1.00"Max group length of Cluster Rounded Indications if more than 1 group is present in a 6" length of weld: 1.0"

UW-52Cracks, Incomplete Penetration, and Incomplete Fusion: None AllowedSlag Inclusions:Max Size of slag inclusions: 0.750"Max Cumulative length of acceptable in-line indications (other than rounded): 1.500" in a 9.0" length ofwelds and must be seperated by the length of 3L of acceptable weld metal.

Technique Sheet Info (Source Side of Object to Film and Source Distances)Reinforcement is found in the applicable penetrameter selection boxes above.

Source to Source Side of Object; As measured in the field.Source Side of Object to Film Distance: 1.500"

Page 316: NDT Code Book Made Easy

S

ASME SECTION VIII - PLATE ONLY

1 9/16" Plate - 1.5625" Wall

PENETRAMETER SELECTIONNote: Esn. Wire: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Hole 35 S/S Wire: 0.032 Esn Wire: B1 or C6 F/S Hole: 30 F/S Wire: 0.025 Esn Wire: B2Reinforced welds welded fromone side: S/S Hole: 35 S/S Wire: 0.032 Esn. Wire: B1 or C6

F/S Hole: 30 S/S Wire: 0.025 Esn. Wire: B2Reinforced welds welded fromtwo sides: S/S Hole: 35 S/S Wire: 0.032 Esn. Wire: B1 or C6

F/S Hole: 30 S/S Wire: 0.025 Esn. Wire: B2

Maximum allowable reinforcement if welded from one side: 0.125" Total of Wall + Reinforcement 1.688"Maximum allowable reinforcement if welded from two sides: 0.250" Total of Wall + Reinforcement 1.813"

PENETRAMETER SELECTION FOR API 620, 650, & 653Welds without reinforcement: Same as aboveWelds with reinforcement: S/S Hole: 35 S/S Wire: 0.032 Esn. Wire: B1 or C6

F/S Hole: 30 F/S Wire: 0.025 Esn. Wire: B2

Maximum allowable reinforcement: 0.125" Total of Wall + Reinforcement 1.688"

UW-51; API 620, 650, & 653Cracks, Incomplete Penetration, and Incomplete Fusion: None AllowedOther Elongated Indications (UW-51 only):Max Length of other elongated indications: 0.521"Max Cumulative length of aligned indications is 1.5625" in a length of weld equal to 18.75" unlessseperated by the length of 6L Rounded Indications (UW-51 Only):Relevant Indications: 0.031Max Size of Random Indications: 0.156" Max Size of Isolated Rounded Indications: 0.250"Max sum of diameters of Aligned Rounded Indications: 1.5625" in a 18.75" length of weldMax group length of Aligned Rounded Indications: 0.521"Max group length of Cluster Rounded Indications if 1 group is present in a 6" length of weld: 1.00"Max group length of Cluster Rounded Indications if more than 1 group is present in a 6" length of weld: 1.0"

UW-52Cracks, Incomplete Penetration, and Incomplete Fusion: None AllowedSlag Inclusions:Max Size of slag inclusions: 0.750"Max Cumulative length of acceptable in-line indications (other than rounded): 1.5625" in a 9.375" length ofwelds and must be seperated by the length of 3L of acceptable weld metal.

Technique Sheet Info (Source Side of Object to Film and Source Distances)Reinforcement is found in the applicable penetrameter selection boxes above.

Source to Source Side of Object; As measured in the field.Source Side of Object to Film Distance: 1.5625"

Page 317: NDT Code Book Made Easy

S

ASME SECTION VIII - PLATE ONLY

1 5/8" Plate - 1.625" Wall

PENETRAMETER SELECTIONNote: Esn. Wire: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Hole 35 S/S Wire: 0.032 Esn Wire: B1 or C6 F/S Hole: 30 F/S Wire: 0.025 Esn Wire: B2Reinforced welds welded fromone side: S/S Hole: 35 S/S Wire: 0.032 Esn. Wire: B1 or C6

F/S Hole: 30 S/S Wire: 0.025 Esn. Wire: B2Reinforced welds welded fromtwo sides: S/S Hole: 35 S/S Wire: 0.032 Esn. Wire: B1 or C6

F/S Hole: 30 S/S Wire: 0.025 Esn. Wire: B2

Maximum allowable reinforcement if welded from one side: 0.125" Total of Wall + Reinforcement 1.750"Maximum allowable reinforcement if welded from two sides: 0.250" Total of Wall + Reinforcement 1.875"

PENETRAMETER SELECTION FOR API 620, 650, & 653Welds without reinforcement: Same as aboveWelds with reinforcement: S/S Hole: 35 S/S Wire: 0.032 Esn. Wire: B1 or C6

F/S Hole: 30 F/S Wire: 0.025 Esn. Wire: B2

Maximum allowable reinforcement: 0.125" Total of Wall + Reinforcement 1.750"

UW-51; API 620, 650, & 653Cracks, Incomplete Penetration, and Incomplete Fusion: None AllowedOther Elongated Indications (UW-51 only):Max Length of other elongated indications: 0.542"Max Cumulative length of aligned indications is 1.625" in a length of weld equal to 19.500" unlessseperated by the length of 6L Rounded Indications (UW-51 Only):Relevant Indications: 0.031Max Size of Random Indications: 0.156" Max Size of Isolated Rounded Indications: 0.250"Max sum of diameters of Aligned Rounded Indications: 1.625" in a 19.500" length of weldMax group length of Aligned Rounded Indications: 0.542"Max group length of Cluster Rounded Indications if 1 group is present in a 6" length of weld: 1.00"Max group length of Cluster Rounded Indications if more than 1 group is present in a 6" length of weld: 1.0"

UW-52Cracks, Incomplete Penetration, and Incomplete Fusion: None AllowedSlag Inclusions:Max Size of slag inclusions: 0.750"Max Cumulative length of acceptable in-line indications (other than rounded): 1.625" in a 9.750" length ofwelds and must be seperated by the length of 3L of acceptable weld metal.

Technique Sheet Info (Source Side of Object to Film and Source Distances)Reinforcement is found in the applicable penetrameter selection boxes above.

Source to Source Side of Object; As measured in the field.Source Side of Object to Film Distance: 1.625"

Page 318: NDT Code Book Made Easy

S

ASME SECTION VIII - PLATE ONLY

1 11/16" Plate - 1.6875" Wall

PENETRAMETER SELECTIONNote: Esn. Wire: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Hole 35 S/S Wire: 0.032 Esn Wire: B1 or C6 F/S Hole: 30 F/S Wire: 0.025 Esn Wire: B2Reinforced welds welded fromone side: S/S Hole: 35 S/S Wire: 0.032 Esn. Wire: B1 or C6

F/S Hole: 30 S/S Wire: 0.025 Esn. Wire: B2Reinforced welds welded fromtwo sides: S/S Hole: 35 S/S Wire: 0.032 Esn. Wire: B1 or C6

F/S Hole: 30 S/S Wire: 0.025 Esn. Wire: B2

Maximum allowable reinforcement if welded from one side: 0.125" Total of Wall + Reinforcement 1.813"Maximum allowable reinforcement if welded from two sides: 0.250" Total of Wall + Reinforcement 1.938"

PENETRAMETER SELECTION FOR API 620, 650, & 653Welds without reinforcement: Same as aboveWelds with reinforcement: S/S Hole: 35 S/S Wire: 0.032 Esn. Wire: B1 or C6

F/S Hole: 30 F/S Wire: 0.025 Esn. Wire: B2

Maximum allowable reinforcement: 0.125" Total of Wall + Reinforcement 1.813"

UW-51; API 620, 650, & 653Cracks, Incomplete Penetration, and Incomplete Fusion: None AllowedOther Elongated Indications (UW-51 only):Max Length of other elongated indications: 0.563"Max Cumulative length of aligned indications is 1.6875" in a length of weld equal to 20.250" unlessseperated by the length of 6L Rounded Indications (UW-51 Only):Relevant Indications: 0.031Max Size of Random Indications: 0.156" Max Size of Isolated Rounded Indications: 0.250"Max sum of diameters of Aligned Rounded Indications: 1.6875" in a 20.250" length of weldMax group length of Aligned Rounded Indications: 0.563"Max group length of Cluster Rounded Indications if 1 group is present in a 6" length of weld: 1.00"Max group length of Cluster Rounded Indications if more than 1 group is present in a 6" length of weld: 1.0"

UW-52Cracks, Incomplete Penetration, and Incomplete Fusion: None AllowedSlag Inclusions:Max Size of slag inclusions: 0.750"Max Cumulative length of acceptable in-line indications (other than rounded): 1.6875" in a 10.125" length ofwelds and must be seperated by the length of 3L of acceptable weld metal.

Technique Sheet Info (Source Side of Object to Film and Source Distances)Reinforcement is found in the applicable penetrameter selection boxes above.

Source to Source Side of Object; As measured in the field.Source Side of Object to Film Distance: 1.6875"

Page 319: NDT Code Book Made Easy

S

ASME SECTION VIII - PLATE ONLY

1 3/4" Plate - 1.750" Wall

PENETRAMETER SELECTIONNote: Esn. Wire: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Hole 35 S/S Wire: 0.032 Esn Wire: B1 or C6 F/S Hole: 30 F/S Wire: 0.025 Esn Wire: B2Reinforced welds welded fromone side: S/S Hole: 35 S/S Wire: 0.032 Esn. Wire: B1 or C6

F/S Hole: 30 S/S Wire: 0.025 Esn. Wire: B2Reinforced welds welded fromtwo sides: S/S Hole: 35 S/S Wire: 0.032 Esn. Wire: B1 or C6

F/S Hole: 30 S/S Wire: 0.025 Esn. Wire: B2

Maximum allowable reinforcement if welded from one side: 0.125" Total of Wall + Reinforcement 1.875"Maximum allowable reinforcement if welded from two sides: 0.250" Total of Wall + Reinforcement 2.000"

PENETRAMETER SELECTION FOR API 620, 650, & 653Welds without reinforcement: Same as aboveWelds with reinforcement: S/S Hole: 35 S/S Wire: 0.032 Esn. Wire: B1 or C6

F/S Hole: 30 F/S Wire: 0.025 Esn. Wire: B2

Maximum allowable reinforcement: 0.125" Total of Wall + Reinforcement 1.875"

UW-51; API 620, 650, & 653Cracks, Incomplete Penetration, and Incomplete Fusion: None AllowedOther Elongated Indications (UW-51 only):Max Length of other elongated indications: 0.583"Max Cumulative length of aligned indications is 1.750" in a length of weld equal to 21.0" unlessseperated by the length of 6L Rounded Indications (UW-51 Only):Relevant Indications: 0.031Max Size of Random Indications: 0.156" Max Size of Isolated Rounded Indications: 0.250"Max sum of diameters of Aligned Rounded Indications: 1.750" in a 21.0" length of weldMax group length of Aligned Rounded Indications: 0.583"Max group length of Cluster Rounded Indications if 1 group is present in a 6" length of weld: 1.00"Max group length of Cluster Rounded Indications if more than 1 group is present in a 6" length of weld: 1.0"

UW-52Cracks, Incomplete Penetration, and Incomplete Fusion: None AllowedSlag Inclusions:Max Size of slag inclusions: 0.750"Max Cumulative length of acceptable in-line indications (other than rounded): 1.750" in a 10.500" length ofwelds and must be seperated by the length of 3L of acceptable weld metal.

Technique Sheet Info (Source Side of Object to Film and Source Distances)Reinforcement is found in the applicable penetrameter selection boxes above.

Source to Source Side of Object; As measured in the field.Source Side of Object to Film Distance: 1.750"

Page 320: NDT Code Book Made Easy

S

ASME SECTION VIII - PIPING ONLY

2" s/10 - 0.109" Wall

PENETRAMETER SELECTIONNote: Esn. Wire: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Hole 12 S/S Wire: 0.008 Esn Wire: A2 F/S Hole: 10 F/S Wire: 0.006 Esn Wire: A3Reinforced welds welded fromone side: S/S Hole: 12 S/S Wire: 0.008 Esn. Wire: A2

F/S Hole: 10 S/S Wire: 0.006 Esn. Wire: A3Reinforced welds welded fromtwo sides: S/S Hole: 15 S/S Wire: 0.010 Esn. Wire: A1 or B6

F/S Hole: 12 S/S Wire: 0.008 Esn. Wire: A2

Maximum allowable reinforcement if welded from one side: 0.125" Total of Wall + Reinforcement 0.234"Maximum allowable reinforcement if welded from two sides: 0.250" Total of Wall + Reinforcement 0.359"

PENETRAMETER SELECTION FOR API 620, 650, & 653Welds without reinforcement: Same as aboveWelds with reinforcement: S/S Hole: 12 S/S Wire: 0.008 Esn. Wire: A2

F/S Hole: 10 F/S Wire: 0.006 Esn. Wire: A3

Maximum allowable reinforcement: 0.0625" Total of Wall + Reinforcement 0.172"

UW-51; API 620, 650, & 653Cracks, Incomplete Penetration, and Incomplete Fusion: None AllowedOther Elongated Indications (UW-51 only):Max Length of other elongated indications: 0.250"Max Cumulative length of aligned indications is 0.109" in a length of weld equal to 1.308" unlessseperated by the length of 6L Rounded Indications (UW-51 Only):Relevant Indications: 0.012Max Size of Random Indications: 0.027" Max Size of Isolated Rounded Indications: 0.036"Max sum of diameters of Aligned Rounded Indications: 0.109" in a 1.308" length of weldMax group length of Aligned Rounded Indications: 0.250"Max group length of Cluster Rounded Indications if 1 group is present in a 6" length of weld: 0.218"Max group length of Cluster Rounded Indications if more than 1 group is present in a 6" length of weld: 1.0"Max number of relevant rounded indications in a 6" length of weld = 12

UW-52Cracks, Incomplete Penetration, and Incomplete Fusion:Slag Inclusions:Max Size of slag inclusions:Max Cumulative length of acceptable in-line indications (other than rounded): 0.109" in a 0.654" length ofwelds and must be seperated by the length of 3L of acceptable weld metal.

Technique Sheet Info (Source Side of Object to Film and Source Distances)Reinforcement is found in the applicable penetrameter selection boxes above.

Source to Source Side of Object; As measured in the field.Source Side of Object to Film Distance: 2.375"

Page 321: NDT Code Book Made Easy

S

ASME SECTION VIII - PIPING ONLY

2" s/40 & Std. - 0.154" Wall

PENETRAMETER SELECTIONNote: Esn. Wire: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Hole 12 S/S Wire: 0.008 Esn Wire: A2 F/S Hole: 10 F/S Wire: 0.006 Esn Wire: A3Reinforced welds welded fromone side: S/S Hole: 15 S/S Wire: 0.010 Esn. Wire: A1 or B6

F/S Hole: 12 S/S Wire: 0.008 Esn. Wire: A2Reinforced welds welded fromtwo sides: S/S Hole: 17 S/S Wire: 0.013 Esn. Wire: B5

F/S Hole: 15 S/S Wire: 0.010 Esn. Wire: A1 or B6

Maximum allowable reinforcement if welded from one side: 0.125" Total of Wall + Reinforcement 0.279"Maximum allowable reinforcement if welded from two sides: 0.250" Total of Wall + Reinforcement 0.404"

PENETRAMETER SELECTION FOR API 620, 650, & 653Welds without reinforcement: Same as aboveWelds with reinforcement: S/S Hole: 12 S/S Wire: 0.008 Esn. Wire: A2

F/S Hole: 10 F/S Wire: 0.006 Esn. Wire: A3

Maximum allowable reinforcement: 0.0625" Total of Wall + Reinforcement 0.217"

UW-51; API 620, 650, & 653Cracks, Incomplete Penetration, and Incomplete Fusion: None AllowedOther Elongated Indications (UW-51 only):Max Length of other elongated indications: 0.250"Max Cumulative length of aligned indications is 0.154" in a length of weld equal to 1.848" unlessseperated by the length of 6L Rounded Indications (UW-51 Only):Relevant Indications: 0.016Max Size of Random Indications: 0.039" Max Size of Isolated Rounded Indications: 0.051"Max sum of diameters of Aligned Rounded Indications: 0.154" in a 1.848" length of weldMax group length of Aligned Rounded Indications: 0.250"Max group length of Cluster Rounded Indications if 1 group is present in a 6" length of weld: 0.308"Max group length of Cluster Rounded Indications if more than 1 group is present in a 6" length of weld: 1.0"

UW-52Cracks, Incomplete Penetration, and Incomplete Fusion:Slag Inclusions:Max Size of slag inclusions: 0.250"Max Cumulative length of acceptable in-line indications (other than rounded): 0.154" in a 0.924"` length ofwelds and must be seperated by the length of 3L of acceptable weld metal.

Technique Sheet Info (Source Side of Object to Film and Source Distances)Reinforcement is found in the applicable penetrameter selection boxes above.

Source to Source Side of Object; As measured in the field.Source Side of Object to Film Distance: 2.375"

Page 322: NDT Code Book Made Easy

S

ASME SECTION VIII - PIPING ONLY

2" s/80 & Extra Strong - 0.218" Wall

PENETRAMETER SELECTIONNote: Esn. Wire: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Hole 12 S/S Wire: 0.008 Esn Wire: A2 F/S Hole: 10 F/S Wire: 0.006 Esn Wire: A3Reinforced welds welded fromone side: S/S Hole: 15 S/S Wire: 0.010 Esn. Wire: A1 or B6

F/S Hole: 12 S/S Wire: 0.008 Esn. Wire: A2Reinforced welds welded fromtwo sides: S/S Hole: 20 S/S Wire: 0.016 Esn. Wire: B4

F/S Hole: 17 S/S Wire: 0.013 Esn. Wire: B5

Maximum allowable reinforcement if welded from one side: 0.156" Total of Wall + Reinforcement 0.374"Maximum allowable reinforcement if welded from two sides: 0.312" Total of Wall + Reinforcement 0.530"

PENETRAMETER SELECTION FOR API 620, 650, & 653Welds without reinforcement: Same as aboveWelds with reinforcement: S/S Hole: 15 S/S Wire: 0.010 Esn. Wire: A1 or B6

F/S Hole: 12 F/S Wire: 0.008 Esn. Wire: A2

Maximum allowable reinforcement: 0.0625" Total of Wall + Reinforcement 0.281"

UW-51; API 620, 650, & 653Cracks, Incomplete Penetration, and Incomplete Fusion: None AllowedOther Elongated Indications (UW-51 only):Max Length of other elongated indications: 0.250"Max Cumulative length of aligned indications is 0.218" in a length of weld equal to 2.616" unlessseperated by the length of 6L Rounded Indications (UW-51 Only):Relevant Indications: 0.016Max Size of Random Indications: 0.055" Max Size of Isolated Rounded Indications: 0.073"Max sum of diameters of Aligned Rounded Indications: 0.218" in a 2.616" length of weldMax group length of Aligned Rounded Indications: 0.250"Max group length of Cluster Rounded Indications if 1 group is present in a 6" length of weld: 0.436"Max group length of Cluster Rounded Indications if more than 1 group is present in a 6" length of weld: 1.0"

UW-52Cracks, Incomplete Penetration, and Incomplete Fusion:Slag Inclusions:Max Size of slag inclusions: 0.250"Max Cumulative length of acceptable in-line indications (other than rounded): 0.218" in a 1.308" length ofwelds and must be seperated by the length of 3L of acceptable weld metal.

Technique Sheet Info (Source Side of Object to Film and Source Distances)Reinforcement is found in the applicable penetrameter selection boxes above.

Source to Source Side of Object; As measured in the field.Source Side of Object to Film Distance: 2.375"

Page 323: NDT Code Book Made Easy

S

ASME SECTION VIII - PIPING ONLY

2" s/160 - 0.344" Wall

PENETRAMETER SELECTIONNote: Esn. Wire: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Hole 15 S/S Wire: 0.010 Esn Wire: A1 or B6 F/S Hole: 12 F/S Wire: 0.008 Esn Wire: A2Reinforced welds welded fromone side: S/S Hole: 17 S/S Wire: 0.013 Esn. Wire: B 5

F/S Hole: 15 S/S Wire: 0.010 Esn. Wire: A1 or B6Reinforced welds welded fromtwo sides: S/S Hole: 20 S/S Wire: 0.016 Esn. Wire: B4

F/S Hole: 17 S/S Wire: 0.013 Esn. Wire: B5

Maximum allowable reinforcement if welded from one side: 0.156" Total of Wall + Reinforcement 0.500"Maximum allowable reinforcement if welded from two sides: 0.312" Total of Wall + Reinforcement 0.656"

PENETRAMETER SELECTION FOR API 620, 650, & 653Welds without reinforcement: Same as aboveWelds with reinforcement: S/S Hole: 17 S/S Wire: 0.013 Esn. Wire: B5

F/S Hole: 15 F/S Wire: 0.010 Esn. Wire: A1 or B6

Maximum allowable reinforcement: 0.0625" Total of Wall + Reinforcement 0.407"

UW-51; API 620, 650, & 653Cracks, Incomplete Penetration, and Incomplete Fusion: None AllowedOther Elongated Indications (UW-51 only):Max Length of other elongated indications: 0.250"Max Cumulative length of aligned indications is 0.344" in a length of weld equal to 4.128" unlessseperated by the length of 6L Rounded Indications (UW-51 Only):Relevant Indications: 0.031Max Size of Random Indications: 0.086" Max Size of Isolated Rounded Indications: 0.115Max sum of diameters of Aligned Rounded Indications: 0.344" in a 4.128" length of weldMax group length of Aligned Rounded Indications: 0.250"Max group length of Cluster Rounded Indications if 1 group is present in a 6" length of weld: 0.688"Max group length of Cluster Rounded Indications if more than 1 group is present in a 6" length of weld: 1.0"

UW-52Cracks, Incomplete Penetration, and Incomplete Fusion:Slag Inclusions:Max Size of slag inclusions: 0.250"Max Cumulative length of acceptable in-line indications (other than rounded): 0.344" in a 2.064" length ofwelds and must be seperated by the length of 3L of acceptable weld metal.

Technique Sheet Info (Source Side of Object to Film and Source Distances)Reinforcement is found in the applicable penetrameter selection boxes above.

Source to Source Side of Object; As measured in the field.Source Side of Object to Film Distance: 2.375"

Page 324: NDT Code Book Made Easy

S

ASME SECTION VIII - PLATE ONLY

2" Plate - 2.00" Wall

PENETRAMETER SELECTIONNote: Esn. Wire: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Hole 35 S/S Wire: 0.032 Esn Wire: B5 F/S Hole: 15 F/S Wire: 0.010 Esn Wire: A1 or B6Reinforced welds welded fromone side: S/S Hole: 20 S/S Wire: 0.016 Esn. Wire: B4

F/S Hole: 17 S/S Wire: 0.013 Esn. Wire: B5Reinforced welds welded fromtwo sides: S/S Hole: 20 S/S Wire: 0.016 Esn. Wire: B4

F/S Hole: 17 S/S Wire: 0.013 Esn. Wire: B5

Maximum allowable reinforcement if welded from one side: 0.156" Total of Wall + Reinforcement 0.592"Maximum allowable reinforcement if welded from two sides: 0.312" Total of Wall + Reinforcement 0.748"

PENETRAMETER SELECTION FOR API 620, 650, & 653Welds without reinforcement: Same as aboveWelds with reinforcement: S/S Hole: 17 S/S Wire: 0.013 Esn. Wire: B5

F/S Hole: 15 F/S Wire: 0.010 Esn. Wire: A1 or B6

Maximum allowable reinforcement: 0.0625" Total of Wall + Reinforcement 0.499"

UW-51; API 620, 650, & 653Cracks, Incomplete Penetration, and Incomplete Fusion: None AllowedOther Elongated Indications (UW-51 only):Max Length of other elongated indications: 0.250"Max Cumulative length of aligned indications is 0.436" in a length of weld equal to 5.232" unlessseperated by the length of 6L Rounded Indications (UW-51 Only):Relevant Indications: 0.031Max Size of Random Indications: 0.109" Max Size of Isolated Rounded Indications: 0.145"Max sum of diameters of Aligned Rounded Indications: 0.436" in a 5.232" length of weldMax group length of Aligned Rounded Indications: 0.250"Max group length of Cluster Rounded Indications if 1 group is present in a 6" length of weld: 0.872"Max group length of Cluster Rounded Indications if more than 1 group is present in a 6" length of weld: 1.0"

UW-52Cracks, Incomplete Penetration, and Incomplete Fusion:Slag Inclusions:Max Size of slag inclusions: 0.291"Max Cumulative length of acceptable in-line indications (other than rounded): 0.436" in a 2.616" length ofwelds and must be seperated by the length of 3L of acceptable weld metal.

Technique Sheet Info (Source Side of Object to Film and Source Distances)Reinforcement is found in the applicable penetrameter selection boxes above.

Source to Source Side of Object; As measured in the field.Source Side of Object to Film Distance: 2.375"

Page 325: NDT Code Book Made Easy

S

ASME SECTION VIII - PLATE ONLY

2" Plate - 2.00" Wall

PENETRAMETER SELECTIONNote: Esn. Wire: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Hole 35 S/S Wire: 0.032 Esn Wire: B1 or C6 F/S Hole: 30 F/S Wire: 0.025 Esn Wire: B2Reinforced welds welded fromone side: S/S Hole: 40 S/S Wire: 0.040 Esn. Wire: C5

F/S Hole: 35 S/S Wire: 0.032 Esn. Wire: B1 or C6Reinforced welds welded fromtwo sides: S/S Hole: 40 S/S Wire: 0.040 Esn. Wire: C5

F/S Hole: 35 S/S Wire: 0.032 Esn. Wire: B1 or C6

Maximum allowable reinforcement if welded from one side: 0.125" Total of Wall + Reinforcement 2.125"Maximum allowable reinforcement if welded from two sides: 0.250" Total of Wall + Reinforcement 2.250"

PENETRAMETER SELECTION FOR API 620, 650, & 653Welds without reinforcement: Same as aboveWelds with reinforcement: S/S Hole: 40 S/S Wire: 0.040 Esn. Wire: C5

F/S Hole: 35 F/S Wire: 0.032 Esn. Wire: B1 or C6

Maximum allowable reinforcement: 0.125" Total of Wall + Reinforcement 2.125"

UW-51; API 620, 650, & 653Cracks, Incomplete Penetration, and Incomplete Fusion: None AllowedOther Elongated Indications (UW-51 only):Max Length of other elongated indications: 0.667"Max Cumulative length of aligned indications is 2.00" in a length of weld equal to 24.0" unlessseperated by the length of 6L Rounded Indications (UW-51 Only):Relevant Indications: 0.031Max Size of Random Indications: 0.156" Max Size of Isolated Rounded Indications: 0.250"Max sum of diameters of Aligned Rounded Indications: 2.00" in a 24.0" length of weldMax group length of Aligned Rounded Indications: 0.667"Max group length of Cluster Rounded Indications if 1 group is present in a 6" length of weld: 1.00"Max group length of Cluster Rounded Indications if more than 1 group is present in a 6" length of weld: 1.0"

UW-52Cracks, Incomplete Penetration, and Incomplete Fusion: None AllowedSlag Inclusions:Max Size of slag inclusions: 0.750"Max Cumulative length of acceptable in-line indications (other than rounded): 2.00" in a 12.0" length ofwelds and must be seperated by the length of 3L of acceptable weld metal.

Technique Sheet Info (Source Side of Object to Film and Source Distances)Reinforcement is found in the applicable penetrameter selection boxes above.

Source to Source Side of Object; As measured in the field.Source Side of Object to Film Distance: 2.00"

Page 326: NDT Code Book Made Easy

S

ASME SECTION VIII - PLATE ONLY

2 1/16" Plate - 2.0625" Wall

PENETRAMETER SELECTIONNote: Esn. Wire: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Hole 40 S/S Wire: 0.040 Esn Wire: C5 F/S Hole: 35 F/S Wire: 0.032 Esn Wire: B1 or C6Reinforced welds welded fromone side: S/S Hole: 40 S/S Wire: 0.040 Esn. Wire: C5

F/S Hole: 35 S/S Wire: 0.032 Esn. Wire: B1 or C6Reinforced welds welded fromtwo sides: S/S Hole: 40 S/S Wire: 0.040 Esn. Wire: C5

F/S Hole: 35 S/S Wire: 0.032 Esn. Wire: B1 or C6

Maximum allowable reinforcement if welded from one side: 0.156" Total of Wall + Reinforcement 2.219"Maximum allowable reinforcement if welded from two sides: 0.3125" Total of Wall + Reinforcement 2.375"

PENETRAMETER SELECTION FOR API 620, 650, & 653Welds without reinforcement: Same as aboveWelds with reinforcement: S/S Hole: 40 S/S Wire: 0.040 Esn. Wire: C5

F/S Hole: 35 F/S Wire: 0.032 Esn. Wire: B1 or C6

Maximum allowable reinforcement: 0.125" Total of Wall + Reinforcement 2.188"

UW-51; API 620, 650, & 653Cracks, Incomplete Penetration, and Incomplete Fusion: None AllowedOther Elongated Indications (UW-51 only):Max Length of other elongated indications: 0.688"Max Cumulative length of aligned indications is 2.0625" in a length of weld equal to 24.750" unlessseperated by the length of 6L Rounded Indications (UW-51 Only):Relevant Indications: 0.063Max Size of Random Indications: 0.156" Max Size of Isolated Rounded Indications: 0.375"Max sum of diameters of Aligned Rounded Indications: 2.0625" in a 24.750" length of weldMax group length of Aligned Rounded Indications: 0.688"Max group length of Cluster Rounded Indications if 1 group is present in a 6" length of weld: 1.00"Max group length of Cluster Rounded Indications if more than 1 group is present in a 6" length of weld: 1.0"

UW-52Cracks, Incomplete Penetration, and Incomplete Fusion: None AllowedSlag Inclusions:Max Size of slag inclusions: 0.750"Max Cumulative length of acceptable in-line indications (other than rounded): 2.0625" in a 12.375" length ofwelds and must be seperated by the length of 3L of acceptable weld metal.

Technique Sheet Info (Source Side of Object to Film and Source Distances)Reinforcement is found in the applicable penetrameter selection boxes above.

Source to Source Side of Object; As measured in the field.Source Side of Object to Film Distance: 2.0625"

Page 327: NDT Code Book Made Easy

S

ASME SECTION VIII - PLATE ONLY

2 1/8" Plate - 2.125" Wall

PENETRAMETER SELECTIONNote: Esn. Wire: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Hole 40 S/S Wire: 0.040 Esn Wire: C5 F/S Hole: 35 F/S Wire: 0.032 Esn Wire: B1 or C6Reinforced welds welded fromone side: S/S Hole: 40 S/S Wire: 0.040 Esn. Wire: C5

F/S Hole: 35 S/S Wire: 0.032 Esn. Wire: B1 or C6Reinforced welds welded fromtwo sides: S/S Hole: 40 S/S Wire: 0.040 Esn. Wire: C5

F/S Hole: 35 S/S Wire: 0.032 Esn. Wire: B1 or C6

Maximum allowable reinforcement if welded from one side: 0.156" Total of Wall + Reinforcement 2.281"Maximum allowable reinforcement if welded from two sides: 0.3125" Total of Wall + Reinforcement 2.438"

PENETRAMETER SELECTION FOR API 620, 650, & 653Welds without reinforcement: Same as aboveWelds with reinforcement: S/S Hole: 40 S/S Wire: 0.040 Esn. Wire: C5

F/S Hole: 35 F/S Wire: 0.032 Esn. Wire: B1 or C6

Maximum allowable reinforcement: 0.125" Total of Wall + Reinforcement 2.250"

UW-51; API 620, 650, & 653Cracks, Incomplete Penetration, and Incomplete Fusion: None AllowedOther Elongated Indications (UW-51 only):Max Length of other elongated indications: 0.708"Max Cumulative length of aligned indications is 2.125" in a length of weld equal to 25.500" unlessseperated by the length of 6L Rounded Indications (UW-51 Only):Relevant Indications: 0.063Max Size of Random Indications: 0.156" Max Size of Isolated Rounded Indications: 0.375"Max sum of diameters of Aligned Rounded Indications: 2.125" in a 25.500" length of weldMax group length of Aligned Rounded Indications: 0.708"Max group length of Cluster Rounded Indications if 1 group is present in a 6" length of weld: 1.00"Max group length of Cluster Rounded Indications if more than 1 group is present in a 6" length of weld: 1.0"

UW-52Cracks, Incomplete Penetration, and Incomplete Fusion: None AllowedSlag Inclusions:Max Size of slag inclusions: 0.750"Max Cumulative length of acceptable in-line indications (other than rounded): 2.125" in a 12.750" length ofwelds and must be seperated by the length of 3L of acceptable weld metal.

Technique Sheet Info (Source Side of Object to Film and Source Distances)Reinforcement is found in the applicable penetrameter selection boxes above.

Source to Source Side of Object; As measured in the field.Source Side of Object to Film Distance: 2.125"

Page 328: NDT Code Book Made Easy

S

ASME SECTION VIII - PLATE ONLY

2 3/16" Plate - 2.1875" Wall

PENETRAMETER SELECTIONNote: Esn. Wire: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Hole 40 S/S Wire: 0.040 Esn Wire: C5 F/S Hole: 35 F/S Wire: 0.032 Esn Wire: B1 or C6Reinforced welds welded fromone side: S/S Hole: 40 S/S Wire: 0.040 Esn. Wire: C5

F/S Hole: 35 S/S Wire: 0.032 Esn. Wire: B1 or C6Reinforced welds welded fromtwo sides: S/S Hole: 40 S/S Wire: 0.040 Esn. Wire: C5

F/S Hole: 35 S/S Wire: 0.032 Esn. Wire: B1 or C6

Maximum allowable reinforcement if welded from one side: 0.156" Total of Wall + Reinforcement 2.344"Maximum allowable reinforcement if welded from two sides: 0.3125" Total of Wall + Reinforcement 2.500"

PENETRAMETER SELECTION FOR API 620, 650, & 653Welds without reinforcement: Same as aboveWelds with reinforcement: S/S Hole: 40 S/S Wire: 0.040 Esn. Wire: C5

F/S Hole: 35 F/S Wire: 0.032 Esn. Wire: B1 or C6

Maximum allowable reinforcement: 0.125" Total of Wall + Reinforcement 2.313"

UW-51; API 620, 650, & 653Cracks, Incomplete Penetration, and Incomplete Fusion: None AllowedOther Elongated Indications (UW-51 only):Max Length of other elongated indications: 0.729"Max Cumulative length of aligned indications is 2.1875" in a length of weld equal to 26.250" unlessseperated by the length of 6L Rounded Indications (UW-51 Only):Relevant Indications: 0.063Max Size of Random Indications: 0.156" Max Size of Isolated Rounded Indications: 0.375"Max sum of diameters of Aligned Rounded Indications: 2.1875" in a 26.250" length of weldMax group length of Aligned Rounded Indications: 0.729"Max group length of Cluster Rounded Indications if 1 group is present in a 6" length of weld: 1.00"Max group length of Cluster Rounded Indications if more than 1 group is present in a 6" length of weld: 1.0"

UW-52Cracks, Incomplete Penetration, and Incomplete Fusion: None AllowedSlag Inclusions:Max Size of slag inclusions: 0.750"Max Cumulative length of acceptable in-line indications (other than rounded): 2.1875" in a 13.125" length ofwelds and must be seperated by the length of 3L of acceptable weld metal.

Technique Sheet Info (Source Side of Object to Film and Source Distances)Reinforcement is found in the applicable penetrameter selection boxes above.

Source to Source Side of Object; As measured in the field.Source Side of Object to Film Distance: 2.1875"

Page 329: NDT Code Book Made Easy

S

ASME SECTION VIII - PLATE ONLY

2 1/4" Plate - 2.250" Wall

PENETRAMETER SELECTIONNote: Esn. Wire: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Hole 40 S/S Wire: 0.040 Esn Wire: C5 F/S Hole: 35 F/S Wire: 0.032 Esn Wire: B1 or C6Reinforced welds welded fromone side: S/S Hole: 40 S/S Wire: 0.040 Esn. Wire: C5

F/S Hole: 35 S/S Wire: 0.032 Esn. Wire: B1 or C6Reinforced welds welded fromtwo sides: S/S Hole: 50 S/S Wire: 0.050 Esn. Wire: C4

F/S Hole: 40 S/S Wire: 0.040 Esn. Wire: C5

Maximum allowable reinforcement if welded from one side: 0.156" Total of Wall + Reinforcement 2.406"Maximum allowable reinforcement if welded from two sides: 0.3125" Total of Wall + Reinforcement 2.563"

PENETRAMETER SELECTION FOR API 620, 650, & 653Welds without reinforcement: Same as aboveWelds with reinforcement: S/S Hole: 40 S/S Wire: 0.040 Esn. Wire: C5

F/S Hole: 35 F/S Wire: 0.032 Esn. Wire: B1 or C6

Maximum allowable reinforcement: 0.125" Total of Wall + Reinforcement 2.375"

UW-51; API 620, 650, & 653Cracks, Incomplete Penetration, and Incomplete Fusion: None AllowedOther Elongated Indications (UW-51 only):Max Length of other elongated indications: 0.750"Max Cumulative length of aligned indications is 2.250" in a length of weld equal to 27.0" unlessseperated by the length of 6L Rounded Indications (UW-51 Only):Relevant Indications: 0.063Max Size of Random Indications: 0.156" Max Size of Isolated Rounded Indications: 0.375"Max sum of diameters of Aligned Rounded Indications: 2.250" in a 27.0" length of weldMax group length of Aligned Rounded Indications: 0.750"Max group length of Cluster Rounded Indications if 1 group is present in a 6" length of weld: 1.00"Max group length of Cluster Rounded Indications if more than 1 group is present in a 6" length of weld: 1.0"

UW-52Cracks, Incomplete Penetration, and Incomplete Fusion: None AllowedSlag Inclusions:Max Size of slag inclusions: 0.750"Max Cumulative length of acceptable in-line indications (other than rounded): 2.250" in a 13.500" length ofwelds and must be seperated by the length of 3L of acceptable weld metal.

Technique Sheet Info (Source Side of Object to Film and Source Distances)Reinforcement is found in the applicable penetrameter selection boxes above.

Source to Source Side of Object; As measured in the field.Source Side of Object to Film Distance: 2.250"

Page 330: NDT Code Book Made Easy

S

ASME SECTION VIII - PLATE ONLY

2 5/16" Plate - 2.3125" Wall

PENETRAMETER SELECTIONNote: Esn. Wire: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Hole 40 S/S Wire: 0.040 Esn Wire: C5 F/S Hole: 35 F/S Wire: 0.032 Esn Wire: B1 or C6Reinforced welds welded fromone side: S/S Hole: 40 S/S Wire: 0.040 Esn. Wire: C5

F/S Hole: 35 S/S Wire: 0.032 Esn. Wire: B1 or C6Reinforced welds welded fromtwo sides: S/S Hole: 50 S/S Wire: 0.050 Esn. Wire: C4

F/S Hole: 40 S/S Wire: 0.040 Esn. Wire: C5

Maximum allowable reinforcement if welded from one side: 0.156" Total of Wall + Reinforcement 2.469"Maximum allowable reinforcement if welded from two sides: 0.3125" Total of Wall + Reinforcement 2.625"

PENETRAMETER SELECTION FOR API 620, 650, & 653Welds without reinforcement: Same as aboveWelds with reinforcement: S/S Hole: 40 S/S Wire: 0.040 Esn. Wire: C5

F/S Hole: 35 F/S Wire: 0.032 Esn. Wire: B1 or C6

Maximum allowable reinforcement: 0.125" Total of Wall + Reinforcement 2.438"

UW-51; API 620, 650, & 653Cracks, Incomplete Penetration, and Incomplete Fusion: None AllowedOther Elongated Indications (UW-51 only):Max Length of other elongated indications: 0.750"Max Cumulative length of aligned indications is 2.3125" in a length of weld equal to 27.750" unlessseperated by the length of 6L Rounded Indications (UW-51 Only):Relevant Indications: 0.063Max Size of Random Indications: 0.156" Max Size of Isolated Rounded Indications: 0.375"Max sum of diameters of Aligned Rounded Indications: 2.3125" in a 27.750" length of weldMax group length of Aligned Rounded Indications: 0.750"Max group length of Cluster Rounded Indications if 1 group is present in a 6" length of weld: 1.00"Max group length of Cluster Rounded Indications if more than 1 group is present in a 6" length of weld: 1.0"

UW-52Cracks, Incomplete Penetration, and Incomplete Fusion: None AllowedSlag Inclusions:Max Size of slag inclusions: 0.750"Max Cumulative length of acceptable in-line indications (other than rounded): 2.3125" in a 13.875" length ofwelds and must be seperated by the length of 3L of acceptable weld metal.

Technique Sheet Info (Source Side of Object to Film and Source Distances)Reinforcement is found in the applicable penetrameter selection boxes above.

Source to Source Side of Object; As measured in the field.Source Side of Object to Film Distance: 2.3125"

Page 331: NDT Code Book Made Easy

S

ASME SECTION VIII - PLATE ONLY

2 3/8" Plate - 2.375" Wall

PENETRAMETER SELECTIONNote: Esn. Wire: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Hole 40 S/S Wire: 0.040 Esn Wire: C5 F/S Hole: 35 F/S Wire: 0.032 Esn Wire: B1 or C6Reinforced welds welded fromone side: S/S Hole: 50 S/S Wire: 0.050 Esn. Wire: C4

F/S Hole: 40 S/S Wire: 0.040 Esn. Wire: C5Reinforced welds welded fromtwo sides: S/S Hole: 50 S/S Wire: 0.050 Esn. Wire: C4

F/S Hole: 40 S/S Wire: 0.040 Esn. Wire: C5

Maximum allowable reinforcement if welded from one side: 0.156" Total of Wall + Reinforcement 2.531"Maximum allowable reinforcement if welded from two sides: 0.3125" Total of Wall + Reinforcement 2.688"

PENETRAMETER SELECTION FOR API 620, 650, & 653Welds without reinforcement: Same as aboveWelds with reinforcement: S/S Hole: 40 S/S Wire: 0.040 Esn. Wire: C5

F/S Hole: 35 F/S Wire: 0.032 Esn. Wire: B1 or C6

Maximum allowable reinforcement: 0.125" Total of Wall + Reinforcement 2.500"

UW-51; API 620, 650, & 653Cracks, Incomplete Penetration, and Incomplete Fusion: None AllowedOther Elongated Indications (UW-51 only):Max Length of other elongated indications: 0.750"Max Cumulative length of aligned indications is 2.375" in a length of weld equal to 28.5" unlessseperated by the length of 6L Rounded Indications (UW-51 Only):Relevant Indications: 0.063Max Size of Random Indications: 0.156" Max Size of Isolated Rounded Indications: 0.375"Max sum of diameters of Aligned Rounded Indications: 2.375" in a 28.5" length of weldMax group length of Aligned Rounded Indications: 0.750"Max group length of Cluster Rounded Indications if 1 group is present in a 6" length of weld: 1.00"Max group length of Cluster Rounded Indications if more than 1 group is present in a 6" length of weld: 1.0"

UW-52Cracks, Incomplete Penetration, and Incomplete Fusion: None AllowedSlag Inclusions:Max Size of slag inclusions: 0.750"Max Cumulative length of acceptable in-line indications (other than rounded): 2.375" in a 14.25" length ofwelds and must be seperated by the length of 3L of acceptable weld metal.

Technique Sheet Info (Source Side of Object to Film and Source Distances)Reinforcement is found in the applicable penetrameter selection boxes above.

Source to Source Side of Object; As measured in the field.Source Side of Object to Film Distance: 2.375"

Page 332: NDT Code Book Made Easy

S

ASME SECTION VIII - PLATE ONLY

2 7/16" Plate - 2.4375" Wall

PENETRAMETER SELECTIONNote: Esn. Wire: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Hole 40 S/S Wire: 0.040 Esn Wire: C5 F/S Hole: 35 F/S Wire: 0.032 Esn Wire: B1 or C6Reinforced welds welded fromone side: S/S Hole: 50 S/S Wire: 0.050 Esn. Wire: C4

F/S Hole: 40 S/S Wire: 0.040 Esn. Wire: C5Reinforced welds welded fromtwo sides: S/S Hole: 50 S/S Wire: 0.050 Esn. Wire: C4

F/S Hole: 40 S/S Wire: 0.040 Esn. Wire: C5

Maximum allowable reinforcement if welded from one side: 0.156" Total of Wall + Reinforcement 2.594"Maximum allowable reinforcement if welded from two sides: 0.3125" Total of Wall + Reinforcement 2.750"

PENETRAMETER SELECTION FOR API 620, 650, & 653Welds without reinforcement: Same as aboveWelds with reinforcement: S/S Hole: 50 S/S Wire: 0.050 Esn. Wire: C4

F/S Hole: 40 F/S Wire: 0.040 Esn. Wire: C5

Maximum allowable reinforcement: 0.125" Total of Wall + Reinforcement 2.563"

UW-51; API 620, 650, & 653Cracks, Incomplete Penetration, and Incomplete Fusion: None AllowedOther Elongated Indications (UW-51 only):Max Length of other elongated indications: 0.750"Max Cumulative length of aligned indications is 2.4375" in a length of weld equal to 29.250" unlessseperated by the length of 6L Rounded Indications (UW-51 Only):Relevant Indications: 0.063Max Size of Random Indications: 0.156" Max Size of Isolated Rounded Indications: 0.375"Max sum of diameters of Aligned Rounded Indications: 2.4375" in a 29.250" length of weldMax group length of Aligned Rounded Indications: 0.750"Max group length of Cluster Rounded Indications if 1 group is present in a 6" length of weld: 1.00"Max group length of Cluster Rounded Indications if more than 1 group is present in a 6" length of weld: 1.0"

UW-52Cracks, Incomplete Penetration, and Incomplete Fusion: None AllowedSlag Inclusions:Max Size of slag inclusions: 0.750"Max Cumulative length of acceptable in-line indications (other than rounded): 2.4375" in a 14.625" length ofwelds and must be seperated by the length of 3L of acceptable weld metal.

Technique Sheet Info (Source Side of Object to Film and Source Distances)Reinforcement is found in the applicable penetrameter selection boxes above.

Source to Source Side of Object; As measured in the field.Source Side of Object to Film Distance: 2.4375"

Page 333: NDT Code Book Made Easy

S

ASME SECTION VIII - PLATE ONLY

2 1/2" Plate - 2.500" Wall

PENETRAMETER SELECTIONNote: Esn. Wire: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Hole 40 S/S Wire: 0.040 Esn Wire: C5 F/S Hole: 35 F/S Wire: 0.032 Esn Wire: B1 or C6Reinforced welds welded fromone side: S/S Hole: 50 S/S Wire: 0.050 Esn. Wire: C4

F/S Hole: 40 S/S Wire: 0.040 Esn. Wire: C5Reinforced welds welded fromtwo sides: S/S Hole: 50 S/S Wire: 0.050 Esn. Wire: C4

F/S Hole: 40 S/S Wire: 0.040 Esn. Wire: C5

Maximum allowable reinforcement if welded from one side: 0.156" Total of Wall + Reinforcement 2.656"Maximum allowable reinforcement if welded from two sides: 0.3125" Total of Wall + Reinforcement 2.813"

PENETRAMETER SELECTION FOR API 620, 650, & 653Welds without reinforcement: Same as aboveWelds with reinforcement: S/S Hole: 50 S/S Wire: 0.050 Esn. Wire: C4

F/S Hole: 40 F/S Wire: 0.040 Esn. Wire: C5

Maximum allowable reinforcement: 0.125" Total of Wall + Reinforcement 2.625"

UW-51; API 620, 650, & 653Cracks, Incomplete Penetration, and Incomplete Fusion: None AllowedOther Elongated Indications (UW-51 only):Max Length of other elongated indications: 0.750"Max Cumulative length of aligned indications is 2.500" in a length of weld equal to 30.0" unlessseperated by the length of 6L Rounded Indications (UW-51 Only):Relevant Indications: 0.063Max Size of Random Indications: 0.156" Max Size of Isolated Rounded Indications: 0.375"Max sum of diameters of Aligned Rounded Indications: 2.500" in a 30.0" length of weldMax group length of Aligned Rounded Indications: 0.750"Max group length of Cluster Rounded Indications if 1 group is present in a 6" length of weld: 1.00"Max group length of Cluster Rounded Indications if more than 1 group is present in a 6" length of weld: 1.0"

UW-52Cracks, Incomplete Penetration, and Incomplete Fusion: None AllowedSlag Inclusions:Max Size of slag inclusions: 0.750"Max Cumulative length of acceptable in-line indications (other than rounded): 2.500" in a 15.0" length ofwelds and must be seperated by the length of 3L of acceptable weld metal.

Technique Sheet Info (Source Side of Object to Film and Source Distances)Reinforcement is found in the applicable penetrameter selection boxes above.

Source to Source Side of Object; As measured in the field.Source Side of Object to Film Distance: 2.500"

Page 334: NDT Code Book Made Easy

S

ASME SECTION VIII - PLATE ONLY

2 9/16" Plate - 2.5625" Wall

PENETRAMETER SELECTIONNote: Esn. Wire: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Hole 50 S/S Wire: 0.050 Esn Wire: C4 F/S Hole: 40 F/S Wire: 0.040 Esn Wire: C5Reinforced welds welded fromone side: S/S Hole: 50 S/S Wire: 0.050 Esn. Wire: C4

F/S Hole: 40 S/S Wire: 0.040 Esn. Wire: C5Reinforced welds welded fromtwo sides: S/S Hole: 50 S/S Wire: 0.050 Esn. Wire: C4

F/S Hole: 40 S/S Wire: 0.040 Esn. Wire: C5

Maximum allowable reinforcement if welded from one side: 0.156" Total of Wall + Reinforcement 2.719"Maximum allowable reinforcement if welded from two sides: 0.3125" Total of Wall + Reinforcement 2.875"

PENETRAMETER SELECTION FOR API 620, 650, & 653Welds without reinforcement: Same as aboveWelds with reinforcement: S/S Hole: 50 S/S Wire: 0.050 Esn. Wire: C4

F/S Hole: 40 F/S Wire: 0.040 Esn. Wire: C5

Maximum allowable reinforcement: 0.125" Total of Wall + Reinforcement 2.688"

UW-51; API 620, 650, & 653Cracks, Incomplete Penetration, and Incomplete Fusion: None AllowedOther Elongated Indications (UW-51 only):Max Length of other elongated indications: 0.750"Max Cumulative length of aligned indications is 2.5625" in a length of weld equal to 30.750" unlessseperated by the length of 6L Rounded Indications (UW-51 Only):Relevant Indications: 0.063Max Size of Random Indications: 0.156" Max Size of Isolated Rounded Indications: 0.375"Max sum of diameters of Aligned Rounded Indications: 2.5625" in a 30.750" length of weldMax group length of Aligned Rounded Indications: 0.750"Max group length of Cluster Rounded Indications if 1 group is present in a 6" length of weld: 1.00"Max group length of Cluster Rounded Indications if more than 1 group is present in a 6" length of weld: 1.0"

UW-52Cracks, Incomplete Penetration, and Incomplete Fusion: None AllowedSlag Inclusions:Max Size of slag inclusions: 0.750"Max Cumulative length of acceptable in-line indications (other than rounded): 2.5625" in a 15.375" length ofwelds and must be seperated by the length of 3L of acceptable weld metal.

Technique Sheet Info (Source Side of Object to Film and Source Distances)Reinforcement is found in the applicable penetrameter selection boxes above.

Source to Source Side of Object; As measured in the field.Source Side of Object to Film Distance: 2.5625"

Page 335: NDT Code Book Made Easy

S

ASME SECTION VIII - PLATE ONLY

2 5/8" Plate - 2.625" Wall

PENETRAMETER SELECTIONNote: Esn. Wire: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Hole 50 S/S Wire: 0.050 Esn Wire: C4 F/S Hole: 40 F/S Wire: 0.040 Esn Wire: C5Reinforced welds welded fromone side: S/S Hole: 50 S/S Wire: 0.050 Esn. Wire: C4

F/S Hole: 40 S/S Wire: 0.040 Esn. Wire: C5Reinforced welds welded fromtwo sides: S/S Hole: 50 S/S Wire: 0.050 Esn. Wire: C4

F/S Hole: 40 S/S Wire: 0.040 Esn. Wire: C5

Maximum allowable reinforcement if welded from one side: 0.156" Total of Wall + Reinforcement 2.781"Maximum allowable reinforcement if welded from two sides: 0.3125" Total of Wall + Reinforcement 2.938"

PENETRAMETER SELECTION FOR API 620, 650, & 653Welds without reinforcement: Same as aboveWelds with reinforcement: S/S Hole: 50 S/S Wire: 0.050 Esn. Wire: C4

F/S Hole: 40 F/S Wire: 0.040 Esn. Wire: C5

Maximum allowable reinforcement: 0.125" Total of Wall + Reinforcement 2.750"

UW-51; API 620, 650, & 653Cracks, Incomplete Penetration, and Incomplete Fusion: None AllowedOther Elongated Indications (UW-51 only):Max Length of other elongated indications: 0.750"Max Cumulative length of aligned indications is 2.625" in a length of weld equal to 31.5" unlessseperated by the length of 6L Rounded Indications (UW-51 Only):Relevant Indications: 0.063Max Size of Random Indications: 0.156" Max Size of Isolated Rounded Indications: 0.375"Max sum of diameters of Aligned Rounded Indications: 2.625" in a 31.5" length of weldMax group length of Aligned Rounded Indications: 0.750"Max group length of Cluster Rounded Indications if 1 group is present in a 6" length of weld: 1.00"Max group length of Cluster Rounded Indications if more than 1 group is present in a 6" length of weld: 1.0"

UW-52Cracks, Incomplete Penetration, and Incomplete Fusion: None AllowedSlag Inclusions:Max Size of slag inclusions: 0.750"Max Cumulative length of acceptable in-line indications (other than rounded): 2.625" in a 15.750" length ofwelds and must be seperated by the length of 3L of acceptable weld metal.

Technique Sheet Info (Source Side of Object to Film and Source Distances)Reinforcement is found in the applicable penetrameter selection boxes above.

Source to Source Side of Object; As measured in the field.Source Side of Object to Film Distance: 2.625"

Page 336: NDT Code Book Made Easy

S

ASME SECTION VIII - PLATE ONLY

2 11/16" Plate - 2.6875" Wall

PENETRAMETER SELECTIONNote: Esn. Wire: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Hole 50 S/S Wire: 0.050 Esn Wire: C4 F/S Hole: 40 F/S Wire: 0.040 Esn Wire: C5Reinforced welds welded fromone side: S/S Hole: 50 S/S Wire: 0.050 Esn. Wire: C4

F/S Hole: 40 S/S Wire: 0.040 Esn. Wire: C5Reinforced welds welded fromtwo sides: S/S Hole: 50 S/S Wire: 0.050 Esn. Wire: C4

F/S Hole: 40 S/S Wire: 0.040 Esn. Wire: C5

Maximum allowable reinforcement if welded from one side: 0.156" Total of Wall + Reinforcement 2.844"Maximum allowable reinforcement if welded from two sides: 0.3125" Total of Wall + Reinforcement 3.000"

PENETRAMETER SELECTION FOR API 620, 650, & 653Welds without reinforcement: Same as aboveWelds with reinforcement: S/S Hole: 50 S/S Wire: 0.050 Esn. Wire: C4

F/S Hole: 40 F/S Wire: 0.040 Esn. Wire: C5

Maximum allowable reinforcement: 0.125" Total of Wall + Reinforcement 2.813"

UW-51; API 620, 650, & 653Cracks, Incomplete Penetration, and Incomplete Fusion: None AllowedOther Elongated Indications (UW-51 only):Max Length of other elongated indications: 0.750"Max Cumulative length of aligned indications is 2.6875" in a length of weld equal to 32.250" unlessseperated by the length of 6L Rounded Indications (UW-51 Only):Relevant Indications: 0.063Max Size of Random Indications: 0.156" Max Size of Isolated Rounded Indications: 0.375"Max sum of diameters of Aligned Rounded Indications: 2.6875" in a 32.250" length of weldMax group length of Aligned Rounded Indications: 0.750"Max group length of Cluster Rounded Indications if 1 group is present in a 6" length of weld: 1.00"Max group length of Cluster Rounded Indications if more than 1 group is present in a 6" length of weld: 1.0"

UW-52Cracks, Incomplete Penetration, and Incomplete Fusion: None AllowedSlag Inclusions:Max Size of slag inclusions: 0.750"Max Cumulative length of acceptable in-line indications (other than rounded): 2.6875" in a 16.125" length ofwelds and must be seperated by the length of 3L of acceptable weld metal.

Technique Sheet Info (Source Side of Object to Film and Source Distances)Reinforcement is found in the applicable penetrameter selection boxes above.

Source to Source Side of Object; As measured in the field.Source Side of Object to Film Distance: 2.6875"

Page 337: NDT Code Book Made Easy

S

ASME SECTION VIII - PLATE ONLY

2 3/4" Plate - 2.750" Wall

PENETRAMETER SELECTIONNote: Esn. Wire: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Hole 50 S/S Wire: 0.050 Esn Wire: C4 F/S Hole: 40 F/S Wire: 0.040 Esn Wire: C5Reinforced welds welded fromone side: S/S Hole: 50 S/S Wire: 0.050 Esn. Wire: C4

F/S Hole: 40 S/S Wire: 0.040 Esn. Wire: C5Reinforced welds welded fromtwo sides: S/S Hole: 50 S/S Wire: 0.050 Esn. Wire: C4

F/S Hole: 40 S/S Wire: 0.040 Esn. Wire: C5

Maximum allowable reinforcement if welded from one side: 0.156" Total of Wall + Reinforcement 2.906"Maximum allowable reinforcement if welded from two sides: 0.3125" Total of Wall + Reinforcement 3.0625"

PENETRAMETER SELECTION FOR API 620, 650, & 653Welds without reinforcement: Same as aboveWelds with reinforcement: S/S Hole: 50 S/S Wire: 0.050 Esn. Wire: C4

F/S Hole: 40 F/S Wire: 0.040 Esn. Wire: C5

Maximum allowable reinforcement: 0.125" Total of Wall + Reinforcement 2.875"

UW-51; API 620, 650, & 653Cracks, Incomplete Penetration, and Incomplete Fusion: None AllowedOther Elongated Indications (UW-51 only):Max Length of other elongated indications: 0.750"Max Cumulative length of aligned indications is 2.750" in a length of weld equal to 33.0" unlessseperated by the length of 6L Rounded Indications (UW-51 Only):Relevant Indications: 0.063Max Size of Random Indications: 0.156" Max Size of Isolated Rounded Indications: 0.375"Max sum of diameters of Aligned Rounded Indications: 2.750" in a 33.0" length of weldMax group length of Aligned Rounded Indications: 0.750"Max group length of Cluster Rounded Indications if 1 group is present in a 6" length of weld: 1.00"Max group length of Cluster Rounded Indications if more than 1 group is present in a 6" length of weld: 1.0"

UW-52Cracks, Incomplete Penetration, and Incomplete Fusion: None AllowedSlag Inclusions:Max Size of slag inclusions: 0.750"Max Cumulative length of acceptable in-line indications (other than rounded): 2.750" in a 16.5" length ofwelds and must be seperated by the length of 3L of acceptable weld metal.

Technique Sheet Info (Source Side of Object to Film and Source Distances)Reinforcement is found in the applicable penetrameter selection boxes above.

Source to Source Side of Object; As measured in the field.Source Side of Object to Film Distance: 2.750"

Page 338: NDT Code Book Made Easy

S

ASME SECTION VIII - PLATE ONLY

2 13/16" Plate - 2.8125" Wall

PENETRAMETER SELECTIONNote: Esn. Wire: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Hole 50 S/S Wire: 0.050 Esn Wire: C4 F/S Hole: 40 F/S Wire: 0.040 Esn Wire: C5Reinforced welds welded fromone side: S/S Hole: 50 S/S Wire: 0.050 Esn. Wire: C4

F/S Hole: 40 S/S Wire: 0.040 Esn. Wire: C5Reinforced welds welded fromtwo sides: S/S Hole: 50 S/S Wire: 0.050 Esn. Wire: C4

F/S Hole: 40 S/S Wire: 0.040 Esn. Wire: C5

Maximum allowable reinforcement if welded from one side: 0.156" Total of Wall + Reinforcement 2.969"Maximum allowable reinforcement if welded from two sides: 0.3125" Total of Wall + Reinforcement 3.125"

PENETRAMETER SELECTION FOR API 620, 650, & 653Welds without reinforcement: Same as aboveWelds with reinforcement: S/S Hole: 50 S/S Wire: 0.050 Esn. Wire: C4

F/S Hole: 40 F/S Wire: 0.040 Esn. Wire: C5

Maximum allowable reinforcement: 0.125" Total of Wall + Reinforcement 2.938"

UW-51; API 620, 650, & 653Cracks, Incomplete Penetration, and Incomplete Fusion: None AllowedOther Elongated Indications (UW-51 only):Max Length of other elongated indications: 0.750"Max Cumulative length of aligned indications is 2.8125" in a length of weld equal to 33.750" unlessseperated by the length of 6L Rounded Indications (UW-51 Only):Relevant Indications: 0.063Max Size of Random Indications: 0.156" Max Size of Isolated Rounded Indications: 0.375"Max sum of diameters of Aligned Rounded Indications: 2.8125" in a 33.750" length of weldMax group length of Aligned Rounded Indications: 0.750"Max group length of Cluster Rounded Indications if 1 group is present in a 6" length of weld: 1.00"Max group length of Cluster Rounded Indications if more than 1 group is present in a 6" length of weld: 1.0"

UW-52Cracks, Incomplete Penetration, and Incomplete Fusion: None AllowedSlag Inclusions:Max Size of slag inclusions: 0.750"Max Cumulative length of acceptable in-line indications (other than rounded): 2.8125" in a 16.875" length ofwelds and must be seperated by the length of 3L of acceptable weld metal.

Technique Sheet Info (Source Side of Object to Film and Source Distances)Reinforcement is found in the applicable penetrameter selection boxes above.

Source to Source Side of Object; As measured in the field.Source Side of Object to Film Distance: 2.8125"

Page 339: NDT Code Book Made Easy

S

ASME SECTION VIII - PLATE ONLY

2 7/8" Plate - 2.875" Wall

PENETRAMETER SELECTIONNote: Esn. Wire: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Hole 50 S/S Wire: 0.050 Esn Wire: C4 F/S Hole: 40 F/S Wire: 0.040 Esn Wire: C5Reinforced welds welded fromone side: S/S Hole: 50 S/S Wire: 0.050 Esn. Wire: C4

F/S Hole: 40 S/S Wire: 0.040 Esn. Wire: C5Reinforced welds welded fromtwo sides: S/S Hole: 50 S/S Wire: 0.050 Esn. Wire: C4

F/S Hole: 40 S/S Wire: 0.040 Esn. Wire: C5

Maximum allowable reinforcement if welded from one side: 0.156" Total of Wall + Reinforcement 3.031"Maximum allowable reinforcement if welded from two sides: 0.3125" Total of Wall + Reinforcement 3.188"

PENETRAMETER SELECTION FOR API 620, 650, & 653Welds without reinforcement: Same as aboveWelds with reinforcement: S/S Hole: 50 S/S Wire: 0.050 Esn. Wire: C4

F/S Hole: 40 F/S Wire: 0.040 Esn. Wire: C5

Maximum allowable reinforcement: 0.125" Total of Wall + Reinforcement 3.00"

UW-51; API 620, 650, & 653Cracks, Incomplete Penetration, and Incomplete Fusion: None AllowedOther Elongated Indications (UW-51 only):Max Length of other elongated indications: 0.750"Max Cumulative length of aligned indications is 2.875" in a length of weld equal to 34.5" unlessseperated by the length of 6L Rounded Indications (UW-51 Only):Relevant Indications: 0.063Max Size of Random Indications: 0.156" Max Size of Isolated Rounded Indications: 0.375"Max sum of diameters of Aligned Rounded Indications: 2.875" in a 34.5" length of weldMax group length of Aligned Rounded Indications: 0.750"Max group length of Cluster Rounded Indications if 1 group is present in a 6" length of weld: 1.00"Max group length of Cluster Rounded Indications if more than 1 group is present in a 6" length of weld: 1.0"

UW-52Cracks, Incomplete Penetration, and Incomplete Fusion: None AllowedSlag Inclusions:Max Size of slag inclusions: 0.750"Max Cumulative length of acceptable in-line indications (other than rounded): 2.875" in a 17.25" length ofwelds and must be seperated by the length of 3L of acceptable weld metal.

Technique Sheet Info (Source Side of Object to Film and Source Distances)Reinforcement is found in the applicable penetrameter selection boxes above.

Source to Source Side of Object; As measured in the field.Source Side of Object to Film Distance: 2.875"

Page 340: NDT Code Book Made Easy

S

ASME SECTION VIII - PLATE ONLY

2 15/16" Plate - 2.9375" Wall

PENETRAMETER SELECTIONNote: Esn. Wire: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Hole 50 S/S Wire: 0.050 Esn Wire: C4 F/S Hole: 40 F/S Wire: 0.040 Esn Wire: C5Reinforced welds welded fromone side: S/S Hole: 50 S/S Wire: 0.050 Esn. Wire: C4

F/S Hole: 40 S/S Wire: 0.040 Esn. Wire: C5Reinforced welds welded fromtwo sides: S/S Hole: 50 S/S Wire: 0.050 Esn. Wire: C4

F/S Hole: 40 S/S Wire: 0.040 Esn. Wire: C5

Maximum allowable reinforcement if welded from one side: 0.156" Total of Wall + Reinforcement 3.094"Maximum allowable reinforcement if welded from two sides: 0.3125" Total of Wall + Reinforcement 3.250"

PENETRAMETER SELECTION FOR API 620, 650, & 653Welds without reinforcement: Same as aboveWelds with reinforcement: S/S Hole: 50 S/S Wire: 0.050 Esn. Wire: C4

F/S Hole: 40 F/S Wire: 0.040 Esn. Wire: C5

Maximum allowable reinforcement: 0.125" Total of Wall + Reinforcement 3.063"

UW-51; API 620, 650, & 653Cracks, Incomplete Penetration, and Incomplete Fusion: None AllowedOther Elongated Indications (UW-51 only):Max Length of other elongated indications: 0.750"Max Cumulative length of aligned indications is 2.9375" in a length of weld equal to 35.250" unlessseperated by the length of 6L Rounded Indications (UW-51 Only):Relevant Indications: 0.063Max Size of Random Indications: 0.156" Max Size of Isolated Rounded Indications: 0.375"Max sum of diameters of Aligned Rounded Indications: 2.9375" in a 35.250" length of weldMax group length of Aligned Rounded Indications: 0.750"Max group length of Cluster Rounded Indications if 1 group is present in a 6" length of weld: 1.00"Max group length of Cluster Rounded Indications if more than 1 group is present in a 6" length of weld: 1.0"

UW-52Cracks, Incomplete Penetration, and Incomplete Fusion: None AllowedSlag Inclusions:Max Size of slag inclusions: 0.750"Max Cumulative length of acceptable in-line indications (other than rounded): 2.9375" in a 17.625" length ofwelds and must be seperated by the length of 3L of acceptable weld metal.

Technique Sheet Info (Source Side of Object to Film and Source Distances)Reinforcement is found in the applicable penetrameter selection boxes above.

Source to Source Side of Object; As measured in the field.Source Side of Object to Film Distance: 2.9375"

Page 341: NDT Code Book Made Easy

S

ASME SECTION VIII - PIPING ONLY

3" s/40 & Std. - 0.216" Wall

PENETRAMETER SELECTIONNote: Esn. Wire: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Hole 12 S/S Wire: 0.008 Esn Wire: A2 F/S Hole: 10 F/S Wire: 0.006 Esn Wire: A3Reinforced welds welded fromone side: S/S Hole: 15 S/S Wire: 0.010 Esn. Wire: A1 or B6

F/S Hole: 12 S/S Wire: 0.008 Esn. Wire: A2Reinforced welds welded fromtwo sides: S/S Hole: 20 S/S Wire: 0.016 Esn. Wire: B4

F/S Hole: 17 S/S Wire: 0.013 Esn. Wire: B5

Maximum allowable reinforcement if welded from one side: 0.156" Total of Wall + Reinforcement 0.372"Maximum allowable reinforcement if welded from two sides: 0.312" Total of Wall + Reinforcement 0.528"

PENETRAMETER SELECTION FOR API 620, 650, & 653Welds without reinforcement: Same as aboveWelds with reinforcement: S/S Hole: 15 S/S Wire: 0.010 Esn. Wire: A1 or B6

F/S Hole: 12 F/S Wire: 0.008 Esn. Wire: A2

Maximum allowable reinforcement: 0.0625" Total of Wall + Reinforcement 0.279"

UW-51; API 620, 650, & 653Cracks, Incomplete Penetration, and Incomplete Fusion: None AllowedOther Elongated Indications (UW-51 only):Max Length of other elongated indications: 0.250"Max Cumulative length of aligned indications is 0.216" in a length of weld equal to 2.592" unlessseperated by the length of 6L Rounded Indications (UW-51 Only):Relevant Indications: 0.016Max Size of Random Indications: 0.054" Max Size of Isolated Rounded Indications: 0.072"Max sum of diameters of Aligned Rounded Indications: 0.216" in a 2.592" length of weldMax group length of Aligned Rounded Indications: 0.250"Max group length of Cluster Rounded Indications if 1 group is present in a 6" length of weld: 0.432"Max group length of Cluster Rounded Indications if more than 1 group is present in a 6" length of weld: 1.0"

UW-52Cracks, Incomplete Penetration, and Incomplete Fusion:Slag Inclusions:Max Size of slag inclusions: 0.250"Max Cumulative length of acceptable in-line indications (other than rounded): 0.216" in a 1.296" length ofwelds and must be seperated by the length of 3L of acceptable weld metal.

Technique Sheet Info (Source Side of Object to Film and Source Distances)Reinforcement is found in the applicable penetrameter selection boxes above.

Source to Source Side of Object distance; DWE/DWV 3.284"Source Side of Object to Film Distance: 0.216"

Page 342: NDT Code Book Made Easy

S

ASME SECTION VIII - PIPING ONLY

3" s/80 & Extra Strong - 0.300" Wall

PENETRAMETER SELECTIONNote: Esn. Wire: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Hole 15 S/S Wire: 0.010 Esn Wire: A1 or B6 F/S Hole: 12 F/S Wire: 0.008 Esn Wire: A2Reinforced welds welded fromone side: S/S Hole: 17 S/S Wire: 0.013 Esn. Wire: B5

F/S Hole: 15 S/S Wire: 0.010 Esn. Wire: A1 or B6Reinforced welds welded fromtwo sides: S/S Hole: 20 S/S Wire: 0.016 Esn. Wire: B4

F/S Hole: 17 S/S Wire: 0.013 Esn. Wire: B5

Maximum allowable reinforcement if welded from one side: 0.156" Total of Wall + Reinforcement 0.456"Maximum allowable reinforcement if welded from two sides: 0.312" Total of Wall + Reinforcement 0.612"

PENETRAMETER SELECTION FOR API 620, 650, & 653Welds without reinforcement: Same as aboveWelds with reinforcement: S/S Hole: 15 S/S Wire: 0.010 Esn. Wire: A1 or B6

F/S Hole: 12 F/S Wire: 0.008 Esn. Wire: A2

Maximum allowable reinforcement: 0.0625" Total of Wall + Reinforcement 0.363"

UW-51; API 620, 650, & 653Cracks, Incomplete Penetration, and Incomplete Fusion: None AllowedOther Elongated Indications (UW-51 only):Max Length of other elongated indications: 0.250"Max Cumulative length of aligned indications is 0.300" in a length of weld equal to 3.600" unlessseperated by the length of 6L Rounded Indications (UW-51 Only):Relevant Indications: 0.031Max Size of Random Indications: 0.075" Max Size of Isolated Rounded Indications: 0.100"Max sum of diameters of Aligned Rounded Indications: 0.300" in a 3.600" length of weldMax group length of Aligned Rounded Indications: 0.250"Max group length of Cluster Rounded Indications if 1 group is present in a 6" length of weld: 0.600"Max group length of Cluster Rounded Indications if more than 1 group is present in a 6" length of weld: 1.0"

UW-52Cracks, Incomplete Penetration, and Incomplete Fusion:Slag Inclusions:Max Size of slag inclusions: 0.250"Max Cumulative length of acceptable in-line indications (other than rounded): 0.300" in a 1.800" length ofwelds and must be seperated by the length of 3L of acceptable weld metal.

Technique Sheet Info (Source Side of Object to Film and Source Distances)Reinforcement is found in the applicable penetrameter selection boxes above.

Source to Source Side of Object distance; DWE/DWV 3.200"Source Side of Object to Film Distance: 0.300"

Page 343: NDT Code Book Made Easy

S

ASME SECTION VIII - PIPING ONLY

3" s/160 - 0.438" Wall

PENETRAMETER SELECTIONNote: Esn. Wire: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Hole 17 S/S Wire: 0.013 Esn Wire: B5 F/S Hole: 15 F/S Wire: 0.010 Esn Wire: A1 or B6Reinforced welds welded fromone side: S/S Hole: 20 S/S Wire: 0.016 Esn. Wire: B4

F/S Hole: 17 S/S Wire: 0.013 Esn. Wire: B5Reinforced welds welded fromtwo sides: S/S Hole: 20 S/S Wire: 0.016 Esn. Wire: B4

F/S Hole: 17 S/S Wire: 0.013 Esn. Wire: B5

Maximum allowable reinforcement if welded from one side: 0.156" Total of Wall + Reinforcement 0.594"Maximum allowable reinforcement if welded from two sides: 0.312" Total of Wall + Reinforcement 0.750"

PENETRAMETER SELECTION FOR API 620, 650, & 653Welds without reinforcement: Same as aboveWelds with reinforcement: S/S Hole: 20 S/S Wire: 0.016 Esn. Wire: B4

F/S Hole: 17 F/S Wire: 0.013 Esn. Wire: B5

Maximum allowable reinforcement: 0.0625" Total of Wall + Reinforcement 0.501"

UW-51; API 620, 650, & 653Cracks, Incomplete Penetration, and Incomplete Fusion: None AllowedOther Elongated Indications (UW-51 only):Max Length of other elongated indications: 0.250"Max Cumulative length of aligned indications is 0.438" in a length of weld equal to 5.256" unlessseperated by the length of 6L Rounded Indications (UW-51 Only):Relevant Indications: 0.031Max Size of Random Indications: 0.110" Max Size of Isolated Rounded Indications: 0.146"Max sum of diameters of Aligned Rounded Indications: 0.438" in a 5.256" length of weldMax group length of Aligned Rounded Indications: 0.250"Max group length of Cluster Rounded Indications if 1 group is present in a 6" length of weld: 0.876"Max group length of Cluster Rounded Indications if more than 1 group is present in a 6" length of weld: 1.0"

UW-52Cracks, Incomplete Penetration, and Incomplete Fusion:Slag Inclusions:Max Size of slag inclusions: 0.292"Max Cumulative length of acceptable in-line indications (other than rounded): 0.438" in a 2.628" length ofwelds and must be seperated by the length of 3L of acceptable weld metal.

Technique Sheet Info (Source Side of Object to Film and Source Distances)Reinforcement is found in the applicable penetrameter selection boxes above.

Source to Source Side of Object distance; DWE/DWV 3.062"Source Side of Object to Film Distance: 0.438"

Page 344: NDT Code Book Made Easy

S

ASME SECTION VIII - PIPING ONLY

3" XX Strong - 0.600" Wall

PENETRAMETER SELECTIONNote: Esn. Wire: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Hole 20 S/S Wire: 0.016 Esn Wire: B4 F/S Hole: 17 F/S Wire: 0.013 Esn Wire: B5Reinforced welds welded fromone side: S/S Hole: 25 S/S Wire: 0.020 Esn. Wire: B3

F/S Hole: 20 S/S Wire: 0.016 Esn. Wire: B4Reinforced welds welded fromtwo sides: S/S Hole: 25 S/S Wire: 0.020 Esn. Wire: B3

F/S Hole: 20 S/S Wire: 0.016 Esn. Wire: B4

Maximum allowable reinforcement if welded from one side: 0.188" Total of Wall + Reinforcement 0.788"Maximum allowable reinforcement if welded from two sides: 0.375" Total of Wall + Reinforcement 0.975"

PENETRAMETER SELECTION FOR API 620, 650, & 653Welds without reinforcement: Same as aboveWelds with reinforcement: S/S Hole: 20 S/S Wire: 0.016 Esn. Wire: B4

F/S Hole: 17 F/S Wire: 0.013 Esn. Wire: B5

Maximum allowable reinforcement: 0.094" Total of Wall + Reinforcement 0.694"

UW-51; API 620, 650, & 653Cracks, Incomplete Penetration, and Incomplete Fusion: None AllowedOther Elongated Indications (UW-51 only):Max Length of other elongated indications: 0.250"Max Cumulative length of aligned indications is 0.600" in a length of weld equal to 7.200" unlessseperated by the length of 6L Rounded Indications (UW-51 Only):Relevant Indications: 0.031Max Size of Random Indications: 0.150" Max Size of Isolated Rounded Indications: 0.200"Max sum of diameters of Aligned Rounded Indications: 0.600" in a 7.200" length of weldMax group length of Aligned Rounded Indications: 0.250"Max group length of Cluster Rounded Indications if 1 group is present in a 6" length of weld: 1.00"Max group length of Cluster Rounded Indications if more than 1 group is present in a 6" length of weld: 1.0"

UW-52Cracks, Incomplete Penetration, and Incomplete Fusion:Slag Inclusions:Max Size of slag inclusions: 0.400"Max Cumulative length of acceptable in-line indications (other than rounded): 0.600" in a 3.600" length ofwelds and must be seperated by the length of 3L of acceptable weld metal.

Technique Sheet Info (Source Side of Object to Film and Source Distances)Reinforcement is found in the applicable penetrameter selection boxes above.

Source to Source Side of Object distance; DWE/DWV 2.900"Source Side of Object to Film Distance: 0.600"

Page 345: NDT Code Book Made Easy

S

ASME SECTION VIII - PLATE ONLY

3" Plate - 3.00" Wall

PENETRAMETER SELECTIONNote: Esn. Wire: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Hole 50 S/S Wire: 0.050 Esn Wire: C4 F/S Hole: 40 F/S Wire: 0.040 Esn Wire: C5Reinforced welds welded fromone side: S/S Hole: 50 S/S Wire: 0.050 Esn. Wire: C4

F/S Hole: 40 S/S Wire: 0.040 Esn. Wire: C5Reinforced welds welded fromtwo sides: S/S Hole: 50 S/S Wire: 0.050 Esn. Wire: C4

F/S Hole: 40 S/S Wire: 0.040 Esn. Wire: C5

Maximum allowable reinforcement if welded from one side: 0.156" Total of Wall + Reinforcement 3.156"Maximum allowable reinforcement if welded from two sides: 0.3125" Total of Wall + Reinforcement 3.3125"

PENETRAMETER SELECTION FOR API 620, 650, & 653Welds without reinforcement: Same as aboveWelds with reinforcement: S/S Hole: 50 S/S Wire: 0.050 Esn. Wire: C4

F/S Hole: 40 F/S Wire: 0.040 Esn. Wire: C5

Maximum allowable reinforcement: 0.125" Total of Wall + Reinforcement 3.125"

UW-51; API 620, 650, & 653Cracks, Incomplete Penetration, and Incomplete Fusion: None AllowedOther Elongated Indications (UW-51 only):Max Length of other elongated indications: 0.750"Max Cumulative length of aligned indications is 3.00" in a length of weld equal to 36.0" unlessseperated by the length of 6L Rounded Indications (UW-51 Only):Relevant Indications: 0.063Max Size of Random Indications: 0.156" Max Size of Isolated Rounded Indications: 0.375"Max sum of diameters of Aligned Rounded Indications: 3.00" in a 36.0" length of weldMax group length of Aligned Rounded Indications: 0.750"Max group length of Cluster Rounded Indications if 1 group is present in a 6" length of weld: 1.00"Max group length of Cluster Rounded Indications if more than 1 group is present in a 6" length of weld: 1.0"

UW-52Cracks, Incomplete Penetration, and Incomplete Fusion: None AllowedSlag Inclusions:Max Size of slag inclusions: 0.750"Max Cumulative length of acceptable in-line indications (other than rounded): 3.00" in a 18.0" length ofwelds and must be seperated by the length of 3L of acceptable weld metal.

Technique Sheet Info (Source Side of Object to Film and Source Distances)Reinforcement is found in the applicable penetrameter selection boxes above.

Source to Source Side of Object; As measured in the field.Source Side of Object to Film Distance: 3.00"

Page 346: NDT Code Book Made Easy

S

ASME SECTION VIII - PIPING ONLY

4" s/10 - 0.120" Wall

PENETRAMETER SELECTIONNote: Esn. Wire: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Hole 12 S/S Wire: 0.008 Esn Wire: A2 F/S Hole: 10 F/S Wire: 0.006 Esn Wire: A3Reinforced welds welded fromone side: S/S Hole: 12 S/S Wire: 0.008 Esn. Wire: A2

F/S Hole: 10 S/S Wire: 0.006 Esn. Wire: A3Reinforced welds welded fromtwo sides: S/S Hole: 15 S/S Wire: 0.010 Esn. Wire: A1 or B6

F/S Hole: 12 S/S Wire: 0.008 Esn. Wire: A2

Maximum allowable reinforcement if welded from one side: 0.125" Total of Wall + Reinforcement 0.245"Maximum allowable reinforcement if welded from two sides: 0.250" Total of Wall + Reinforcement 0.370"

PENETRAMETER SELECTION FOR API 620, 650, & 653Welds without reinforcement: Same as aboveWelds with reinforcement: S/S Hole: 12 S/S Wire: 0.008 Esn. Wire: A2

F/S Hole: 10 F/S Wire: 0.006 Esn. Wire: A3

Maximum allowable reinforcement: 0.0625" Total of Wall + Reinforcement 0.183"

UW-51; API 620, 650, & 653Cracks, Incomplete Penetration, and Incomplete Fusion: None AllowedOther Elongated Indications (UW-51 only):Max Length of other elongated indications: 0.250"Max Cumulative length of aligned indications is 0.120" in a length of weld equal to 1.440" unlessseperated by the length of 6L Rounded Indications (UW-51 Only):Relevant Indications: 0.013Max Size of Random Indications: 0.030" Max Size of Isolated Rounded Indications: 0.040"Max sum of diameters of Aligned Rounded Indications: 0.120" in a 1.440" length of weldMax group length of Aligned Rounded Indications: 0.250"Max group length of Cluster Rounded Indications if 1 group is present in a 6" length of weld: 0.240"Max group length of Cluster Rounded Indications if more than 1 group is present in a 6" length of weld: 1.0"Max number or relevant rounded indications in a 6" length of weld = 12UW-52Cracks, Incomplete Penetration, and Incomplete Fusion:Slag Inclusions:Max Size of slag inclusions: 0.250"Max Cumulative length of acceptable in-line indications (other than rounded): 0.120" in a 0.720" length ofwelds and must be seperated by the length of 3L of acceptable weld metal.

Technique Sheet Info (Source Side of Object to Film and Source Distances)Reinforcement is found in the applicable penetrameter selection boxes above.

Source to Source Side of Object distance; DWE/DWV 4.380"Source Side of Object to Film Distance: 0.120"

Page 347: NDT Code Book Made Easy

S

ASME SECTION VIII - PIPING ONLY

4" s/40 & Std. - 0.237" Wall

PENETRAMETER SELECTIONNote: Esn. Wire: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Hole 12 S/S Wire: 0.008 Esn Wire: A2 F/S Hole: 10 F/S Wire: 0.006 Esn Wire: A3Reinforced welds welded fromone side: S/S Hole: 17 S/S Wire: 0.013 Esn. Wire: B5

F/S Hole: 15 S/S Wire: 0.010 Esn. Wire: A1 or B6Reinforced welds welded fromtwo sides: S/S Hole: 20 S/S Wire: 0.016 Esn. Wire: B4

F/S Hole: 17 S/S Wire: 0.013 Esn. Wire: B5

Maximum allowable reinforcement if welded from one side: 0.156" Total of Wall + Reinforcement 0.393"Maximum allowable reinforcement if welded from two sides: 0.312" Total of Wall + Reinforcement 0.549"

PENETRAMETER SELECTION FOR API 620, 650, & 653Welds without reinforcement: Same as aboveWelds with reinforcement: S/S Hole: 15 S/S Wire: 0.010 Esn. Wire: A1 or B6

F/S Hole: 12 F/S Wire: 0.008 Esn. Wire: A2

Maximum allowable reinforcement: 0.0625" Total of Wall + Reinforcement 0.300"

UW-51; API 620, 650, & 653Cracks, Incomplete Penetration, and Incomplete Fusion: None AllowedOther Elongated Indications (UW-51 only):Max Length of other elongated indications: 0.250"Max Cumulative length of aligned indications is 0.237" in a length of weld equal to 2.844" unlessseperated by the length of 6L Rounded Indications (UW-51 Only):Relevant Indications: 0.016Max Size of Random Indications: 0.059" Max Size of Isolated Rounded Indications: 0.079"Max sum of diameters of Aligned Rounded Indications: 0.237" in a 2.844" length of weldMax group length of Aligned Rounded Indications: 0.250"Max group length of Cluster Rounded Indications if 1 group is present in a 6" length of weld: 0.474"Max group length of Cluster Rounded Indications if more than 1 group is present in a 6" length of weld: 1.0"

UW-52Cracks, Incomplete Penetration, and Incomplete Fusion:Slag Inclusions:Max Size of slag inclusions: 0.250"Max Cumulative length of acceptable in-line indications (other than rounded): 0.237" in a 1.422" length ofwelds and must be seperated by the length of 3L of acceptable weld metal.

Technique Sheet Info (Source Side of Object to Film and Source Distances)Reinforcement is found in the applicable penetrameter selection boxes above.

Source to Source Side of Object distance; DWE/DWV 4.263"Source Side of Object to Film Distance: 0.237"

Page 348: NDT Code Book Made Easy

S

ASME SECTION VIII - PIPING ONLY

4" s/80 & Extra Strong - 0.337" Wall

PENETRAMETER SELECTIONNote: Esn. Wire: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Hole 15 S/S Wire: 0.010 Esn Wire: A1 or B6 F/S Hole: 12 F/S Wire: 0.008 Esn Wire: A2Reinforced welds welded fromone side: S/S Hole: 17 S/S Wire: 0.013 Esn. Wire: B5

F/S Hole: 15 S/S Wire: 0.010 Esn. Wire: A1 or B6Reinforced welds welded fromtwo sides: S/S Hole: 20 S/S Wire: 0.016 Esn. Wire: B4

F/S Hole: 17 S/S Wire: 0.013 Esn. Wire: B5

Maximum allowable reinforcement if welded from one side: 0.156" Total of Wall + Reinforcement 0.493"Maximum allowable reinforcement if welded from two sides: 0.312" Total of Wall + Reinforcement 0.649"

PENETRAMETER SELECTION FOR API 620, 650, & 653Welds without reinforcement: Same as aboveWelds with reinforcement: S/S Hole: 17 S/S Wire: 0.013 Esn. Wire: B5

F/S Hole: 15 F/S Wire: 0.010 Esn. Wire: A1 or B6

Maximum allowable reinforcement: 0.0625" Total of Wall + Reinforcement 0.400"

UW-51; API 620, 650, & 653Cracks, Incomplete Penetration, and Incomplete Fusion: None AllowedOther Elongated Indications (UW-51 only):Max Length of other elongated indications: 0.250"Max Cumulative length of aligned indications is 0.337" in a length of weld equal to 4.044" unlessseperated by the length of 6L Rounded Indications (UW-51 Only):Relevant Indications: 0.031Max Size of Random Indications: 0.084" Max Size of Isolated Rounded Indications: 0.112"Max sum of diameters of Aligned Rounded Indications: 0.337" in a 4.044" length of weldMax group length of Aligned Rounded Indications: 0.250"Max group length of Cluster Rounded Indications if 1 group is present in a 6" length of weld: 0.674"Max group length of Cluster Rounded Indications if more than 1 group is present in a 6" length of weld: 1.0"

UW-52Cracks, Incomplete Penetration, and Incomplete Fusion:Slag Inclusions:Max Size of slag inclusions: 0.250"Max Cumulative length of acceptable in-line indications (other than rounded): 0.337" in a 2.022" length ofwelds and must be seperated by the length of 3L of acceptable weld metal.

Technique Sheet Info (Source Side of Object to Film and Source Distances)Reinforcement is found in the applicable penetrameter selection boxes above.

Source to Source Side of Object distance; DWE/DWV 4.163"Source Side of Object to Film Distance: 0.337"

Page 349: NDT Code Book Made Easy

S

ASME SECTION VIII - PIPING ONLY

4" s/120 - 0.438" Wall

PENETRAMETER SELECTIONNote: Esn. Wire: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Hole 17 S/S Wire: 0.013 Esn Wire: B5 F/S Hole: 15 F/S Wire: 0.010 Esn Wire: A1 or B6Reinforced welds welded fromone side: S/S Hole: 20 S/S Wire: 0.016 Esn. Wire: B4

F/S Hole: 17 S/S Wire: 0.013 Esn. Wire: B5Reinforced welds welded fromtwo sides: S/S Hole: 20 S/S Wire: 0.016 Esn. Wire: B4

F/S Hole: 17 S/S Wire: 0.013 Esn. Wire: B5

Maximum allowable reinforcement if welded from one side: 0.156" Total of Wall + Reinforcement 0.594"Maximum allowable reinforcement if welded from two sides: 0.312" Total of Wall + Reinforcement 0.750"

PENETRAMETER SELECTION FOR API 620, 650, & 653Welds without reinforcement: Same as aboveWelds with reinforcement: S/S Hole: 20 S/S Wire: 0.016 Esn. Wire: B4

F/S Hole: 17 F/S Wire: 0.013 Esn. Wire: B5

Maximum allowable reinforcement: 0.0625" Total of Wall + Reinforcement 0.501"

UW-51; API 620, 650, & 653Cracks, Incomplete Penetration, and Incomplete Fusion: None AllowedOther Elongated Indications (UW-51 only):Max Length of other elongated indications: 0.250"Max Cumulative length of aligned indications is 0.438" in a length of weld equal to 5.256" unlessseperated by the length of 6L Rounded Indications (UW-51 Only):Relevant Indications: 0.031Max Size of Random Indications: 0.110" Max Size of Isolated Rounded Indications: 0.146"Max sum of diameters of Aligned Rounded Indications: 0.438" in a 5.256" length of weldMax group length of Aligned Rounded Indications: 0.250"Max group length of Cluster Rounded Indications if 1 group is present in a 6" length of weld: 0.876"Max group length of Cluster Rounded Indications if more than 1 group is present in a 6" length of weld: 1.0"

UW-52Cracks, Incomplete Penetration, and Incomplete Fusion:Slag Inclusions:Max Size of slag inclusions: 0.292"Max Cumulative length of acceptable in-line indications (other than rounded): 0.438" in a 2.628" length ofwelds and must be seperated by the length of 3L of acceptable weld metal.

Technique Sheet Info (Source Side of Object to Film and Source Distances)Reinforcement is found in the applicable penetrameter selection boxes above.

Source to Source Side of Object distance; DWE/DWV 4.062"Source Side of Object to Film Distance: 0.438"

Page 350: NDT Code Book Made Easy

S

ASME SECTION VIII - PIPING ONLY

4" s/160 - 0.531" Wall

PENETRAMETER SELECTIONNote: Esn. Wire: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Hole 20 S/S Wire: 0.016 Esn Wire: B4 F/S Hole: 17 F/S Wire: 0.013 Esn Wire: B5Reinforced welds welded fromone side: S/S Hole: 20 S/S Wire: 0.016 Esn. Wire: B4

F/S Hole: 17 S/S Wire: 0.013 Esn. Wire: B5Reinforced welds welded fromtwo sides: S/S Hole: 25 S/S Wire: 0.020 Esn. Wire: B3

F/S Hole: 20 S/S Wire: 0.016 Esn. Wire: B4

Maximum allowable reinforcement if welded from one side: 0.188" Total of Wall + Reinforcement 0.719"Maximum allowable reinforcement if welded from two sides: 0.375" Total of Wall + Reinforcement 0.906"

PENETRAMETER SELECTION FOR API 620, 650, & 653Welds without reinforcement: Same as aboveWelds with reinforcement: S/S Hole: 20 S/S Wire: 0.016 Esn. Wire: B4

F/S Hole: 17 F/S Wire: 0.013 Esn. Wire: B5

Maximum allowable reinforcement: 0.094" Total of Wall + Reinforcement 0.625"

UW-51; API 620, 650, & 653Cracks, Incomplete Penetration, and Incomplete Fusion: None AllowedOther Elongated Indications (UW-51 only):Max Length of other elongated indications: 0.250"Max Cumulative length of aligned indications is 0.531" in a length of weld equal to 6.372" unlessseperated by the length of 6L Rounded Indications (UW-51 Only):Relevant Indications: 0.031Max Size of Random Indications: 0.133" Max Size of Isolated Rounded Indications: 0.177"Max sum of diameters of Aligned Rounded Indications: 0.531" in a 6.372" length of weldMax group length of Aligned Rounded Indications: 0.250"Max group length of Cluster Rounded Indications if 1 group is present in a 6" length of weld: 1.0"Max group length of Cluster Rounded Indications if more than 1 group is present in a 6" length of weld: 1.0"

UW-52Cracks, Incomplete Penetration, and Incomplete Fusion:Slag Inclusions:Max Size of slag inclusions: 0.354"Max Cumulative length of acceptable in-line indications (other than rounded): 0.531" in a 3.186" length ofwelds and must be seperated by the length of 3L of acceptable weld metal.

Technique Sheet Info (Source Side of Object to Film and Source Distances)Reinforcement is found in the applicable penetrameter selection boxes above.

Source to Source Side of Object distance; DWE/DWV 3.969"Source Side of Object to Film Distance: 0.531"

Page 351: NDT Code Book Made Easy

S

ASME SECTION VIII - PIPING ONLY

4" XX Strong - 0.674" Wall

PENETRAMETER SELECTIONNote: Esn. Wire: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Hole 20 S/S Wire: 0.016 Esn Wire: B4 F/S Hole: 17 F/S Wire: 0.013 Esn Wire: B5Reinforced welds welded fromone side: S/S Hole: 25 S/S Wire: 0.020 Esn. Wire: B3

F/S Hole: 20 S/S Wire: 0.016 Esn. Wire: B4Reinforced welds welded fromtwo sides: S/S Hole: 30 S/S Wire: 0.025 Esn. Wire: B2

F/S Hole: 25 S/S Wire: 0.020 Esn. Wire: B3

Maximum allowable reinforcement if welded from one side: 0.188" Total of Wall + Reinforcement 0.862"Maximum allowable reinforcement if welded from two sides: 0.375" Total of Wall + Reinforcement 1.049"

PENETRAMETER SELECTION FOR API 620, 650, & 653Welds without reinforcement: Same as aboveWelds with reinforcement: S/S Hole: 25 S/S Wire: 0.020 Esn. Wire: B3

F/S Hole: 20 F/S Wire: 0.016 Esn. Wire: B4

Maximum allowable reinforcement: 0.094" Total of Wall + Reinforcement 0.768"

UW-51; API 620, 650, & 653Cracks, Incomplete Penetration, and Incomplete Fusion: None AllowedOther Elongated Indications (UW-51 only):Max Length of other elongated indications: 0.250"Max Cumulative length of aligned indications is 0.674" in a length of weld equal to 8.088" unlessseperated by the length of 6L Rounded Indications (UW-51 Only):Relevant Indications: 0.031Max Size of Random Indications: 0.156" Max Size of Isolated Rounded Indications: 0.225"Max sum of diameters of Aligned Rounded Indications: 0.674" in a 8.088" length of weldMax group length of Aligned Rounded Indications: 0.250"Max group length of Cluster Rounded Indications if 1 group is present in a 6" length of weld: 1.0"Max group length of Cluster Rounded Indications if more than 1 group is present in a 6" length of weld: 1.0"

UW-52Cracks, Incomplete Penetration, and Incomplete Fusion:Slag Inclusions:Max Size of slag inclusions: 0.450"Max Cumulative length of acceptable in-line indications (other than rounded): 0.674" in a 4.044" length ofwelds and must be seperated by the length of 3L of acceptable weld metal.

Technique Sheet Info (Source Side of Object to Film and Source Distances)Reinforcement is found in the applicable penetrameter selection boxes above.

Source to Source Side of Object distance; DWE/DWV 3.826"Source Side of Object to Film Distance: 0.674"

Page 352: NDT Code Book Made Easy

S

ASME SECTION VIII - PIPING ONLY

4" XX Strong - 0.674" Wall

PENETRAMETER SELECTIONNote: Esn. Wire: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Hole 20 S/S Wire: 0.016 Esn Wire: B4 F/S Hole: 17 F/S Wire: 0.013 Esn Wire: B5Reinforced welds welded fromone side: S/S Hole: 25 S/S Wire: 0.020 Esn. Wire: B3

F/S Hole: 20 S/S Wire: 0.016 Esn. Wire: B4Reinforced welds welded fromtwo sides: S/S Hole: 30 S/S Wire: 0.025 Esn. Wire: B2

F/S Hole: 25 S/S Wire: 0.020 Esn. Wire: B3

Maximum allowable reinforcement if welded from one side: 0.188" Total of Wall + Reinforcement 0.862"Maximum allowable reinforcement if welded from two sides: 0.375" Total of Wall + Reinforcement 1.049"

PENETRAMETER SELECTION FOR API 620, 650, & 653Welds without reinforcement: Same as aboveWelds with reinforcement: S/S Hole: 25 S/S Wire: 0.020 Esn. Wire: B3

F/S Hole: 20 F/S Wire: 0.016 Esn. Wire: B4

Maximum allowable reinforcement: 0.094" Total of Wall + Reinforcement 0.768"

UW-51; API 620, 650, & 653Cracks, Incomplete Penetration, and Incomplete Fusion: None AllowedOther Elongated Indications (UW-51 only):Max Length of other elongated indications: 0.250"Max Cumulative length of aligned indications is 0.674" in a length of weld equal to 8.088" unlessseperated by the length of 6L Rounded Indications (UW-51 Only):Relevant Indications: 0.031Max Size of Random Indications: 0.156" Max Size of Isolated Rounded Indications: 0.225"Max sum of diameters of Aligned Rounded Indications: 0.674" in a 8.088" length of weldMax group length of Aligned Rounded Indications: 0.250"Max group length of Cluster Rounded Indications if 1 group is present in a 6" length of weld: 1.0"Max group length of Cluster Rounded Indications if more than 1 group is present in a 6" length of weld: 1.0"

UW-52Cracks, Incomplete Penetration, and Incomplete Fusion:Slag Inclusions:Max Size of slag inclusions: 0.450"Max Cumulative length of acceptable in-line indications (other than rounded): 0.674" in a 4.044" length ofwelds and must be seperated by the length of 3L of acceptable weld metal.

Technique Sheet Info (Source Side of Object to Film and Source Distances)Reinforcement is found in the applicable penetrameter selection boxes above.

Source to Source Side of Object distance; DWE/DWV 3.826"Source Side of Object to Film Distance: 0.674"

Page 353: NDT Code Book Made Easy

S

ASME SECTION VIII - PIPING ONLY

6" s/10 - 0.134" Wall

PENETRAMETER SELECTIONNote: Esn. Wire: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Hole 12 S/S Wire: 0.008 Esn Wire: A2 F/S Hole: 10 F/S Wire: 0.006 Esn Wire: A3Reinforced welds welded fromone side: S/S Hole: 15 S/S Wire: 0.010 Esn. Wire: A1 or B6

F/S Hole: 12 S/S Wire: 0.008 Esn. Wire: A2Reinforced welds welded fromtwo sides: S/S Hole: 17 S/S Wire: 0.013 Esn. Wire: B5

F/S Hole: 15 S/S Wire: 0.010 Esn. Wire: A1 or B6

Maximum allowable reinforcement if welded from one side: 0.125" Total of Wall + Reinforcement 0.259"Maximum allowable reinforcement if welded from two sides: 0.250" Total of Wall + Reinforcement 0.384"

PENETRAMETER SELECTION FOR API 620, 650, & 653Welds without reinforcement: Same as aboveWelds with reinforcement: S/S Hole: 12 S/S Wire: 0.008 Esn. Wire: A2

F/S Hole: 10 F/S Wire: 0.006 Esn. Wire: A3

Maximum allowable reinforcement: 0.0625" Total of Wall + Reinforcement 0.197"

UW-51; API 620, 650, & 653Cracks, Incomplete Penetration, and Incomplete Fusion: None AllowedOther Elongated Indications (UW-51 only):Max Length of other elongated indications: 0.250"Max Cumulative length of aligned indications is 0.134" in a length of weld equal to 1.608" unlessseperated by the length of 6L Rounded Indications (UW-51 Only):Relevant Indications: 0.031Max Size of Random Indications: 0.034" Max Size of Isolated Rounded Indications: 0.045"Max sum of diameters of Aligned Rounded Indications: 0.134" in a 1.608" length of weldMax group length of Aligned Rounded Indications: 0.250"Max group length of Cluster Rounded Indications if 1 group is present in a 6" length of weld: 0.268"Max group length of Cluster Rounded Indications if more than 1 group is present in a 6" length of weld: 1.0"

UW-52Cracks, Incomplete Penetration, and Incomplete Fusion:Slag Inclusions:Max Size of slag inclusions: 0.250"Max Cumulative length of acceptable in-line indications (other than rounded): 0.134" in a 0.804" length ofwelds and must be seperated by the length of 3L of acceptable weld metal.

Technique Sheet Info (Source Side of Object to Film and Source Distances)Reinforcement is found in the applicable penetrameter selection boxes above.

Source to Source Side of Object distance; DWE/DWV 6.491" Panoramic: 3.179"Source Side of Object to Film Distance: 0.134"

Page 354: NDT Code Book Made Easy

S

ASME SECTION VIII - PIPING ONLY

6" s/40 & Std. - 0.280" Wall

PENETRAMETER SELECTIONNote: Esn. Wire: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Hole 15 S/S Wire: 0.010 Esn Wire: A1 or B6 F/S Hole: 12 F/S Wire: 0.008 Esn Wire: A2Reinforced welds welded fromone side: S/S Hole: 17 S/S Wire: 0.013 Esn. Wire: B5

F/S Hole: 15 S/S Wire: 0.010 Esn. Wire: A1 or B6Reinforced welds welded fromtwo sides: S/S Hole: 20 S/S Wire: 0.016 Esn. Wire: B4

F/S Hole: 17 S/S Wire: 0.013 Esn. Wire: B5

Maximum allowable reinforcement if welded from one side: 0.156" Total of Wall + Reinforcement 0.436"Maximum allowable reinforcement if welded from two sides: 0.312" Total of Wall + Reinforcement 0.592"

PENETRAMETER SELECTION FOR API 620, 650, & 653Welds without reinforcement: Same as aboveWelds with reinforcement: S/S Hole: 15 S/S Wire: 0.010 Esn. Wire: A1 or B6

F/S Hole: 12 F/S Wire: 0.008 Esn. Wire: A2

Maximum allowable reinforcement: 0.0625" Total of Wall + Reinforcement 0.343

UW-51; API 620, 650, & 653Cracks, Incomplete Penetration, and Incomplete Fusion: None AllowedOther Elongated Indications (UW-51 only):Max Length of other elongated indications: 0.250"Max Cumulative length of aligned indications is 0.280" in a length of weld equal to 3.360" unlessseperated by the length of 6L Rounded Indications (UW-51 Only):Relevant Indications: 0.031Max Size of Random Indications: 0.070" Max Size of Isolated Rounded Indications: 0.093"Max sum of diameters of Aligned Rounded Indications: 0.280" in a 3.360" length of weldMax group length of Aligned Rounded Indications: 0.250"Max group length of Cluster Rounded Indications if 1 group is present in a 6" length of weld: 0.560"Max group length of Cluster Rounded Indications if more than 1 group is present in a 6" length of weld: 1.0"

UW-52Cracks, Incomplete Penetration, and Incomplete Fusion:Slag Inclusions:Max Size of slag inclusions: 0.250"Max Cumulative length of acceptable in-line indications (other than rounded): 0.280" in a 1.680" length ofwelds and must be seperated by the length of 3L of acceptable weld metal.

Technique Sheet Info (Source Side of Object to Film and Source Distances)Reinforcement is found in the applicable penetrameter selection boxes above.

Source to Source Side of Object distance; DWE/DWV 6.345" Panoramic: 3.033"Source Side of Object to Film Distance: 0.280"

Page 355: NDT Code Book Made Easy

S

ASME SECTION VIII - PIPING ONLY

6" s/80 & Extra Strong - 0.432" Wall

PENETRAMETER SELECTIONNote: Esn. Wire: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Hole 17 S/S Wire: 0.013 Esn Wire: B5 F/S Hole: 15 F/S Wire: 0.010 Esn Wire: A1 or B6Reinforced welds welded fromone side: S/S Hole: 20 S/S Wire: 0.016 Esn. Wire: B4

F/S Hole: 17 S/S Wire: 0.013 Esn. Wire: B5Reinforced welds welded fromtwo sides: S/S Hole: 20 S/S Wire: 0.016 Esn. Wire: B4

F/S Hole: 17 S/S Wire: 0.013 Esn. Wire: B5

Maximum allowable reinforcement if welded from one side: 0.156" Total of Wall + Reinforcement 0.588"Maximum allowable reinforcement if welded from two sides: 0.312" Total of Wall + Reinforcement 0.744"

PENETRAMETER SELECTION FOR API 620, 650, & 653Welds without reinforcement: Same as aboveWelds with reinforcement: S/S Hole: 17 S/S Wire: 0.013 Esn. Wire: B5

F/S Hole: 15 F/S Wire: 0.010 Esn. Wire: A1 or B6

Maximum allowable reinforcement: 0.0625" Total of Wall + Reinforcement 0.495"

UW-51; API 620, 650, & 653Cracks, Incomplete Penetration, and Incomplete Fusion: None AllowedOther Elongated Indications (UW-51 only):Max Length of other elongated indications: 0.250"Max Cumulative length of aligned indications is 0.432" in a length of weld equal to 5.184" unlessseperated by the length of 6L Rounded Indications (UW-51 Only):Relevant Indications: 0.031Max Size of Random Indications: 0.108" Max Size of Isolated Rounded Indications: 0.144"Max sum of diameters of Aligned Rounded Indications: 0.432" in a 5.184" length of weldMax group length of Aligned Rounded Indications: 0.250"Max group length of Cluster Rounded Indications if 1 group is present in a 6" length of weld: 0.864"Max group length of Cluster Rounded Indications if more than 1 group is present in a 6" length of weld: 1.0"

UW-52Cracks, Incomplete Penetration, and Incomplete Fusion:Slag Inclusions:Max Size of slag inclusions: 0.288"Max Cumulative length of acceptable in-line indications (other than rounded): 0.432" in a 2.592" length ofwelds and must be seperated by the length of 3L of acceptable weld metal.

Technique Sheet Info (Source Side of Object to Film and Source Distances)Reinforcement is found in the applicable penetrameter selection boxes above.

Source to Source Side of Object distance; DWE/DWV 6.193" Panoramic: 2.881"Source Side of Object to Film Distance: 0.432"

Page 356: NDT Code Book Made Easy

S

ASME SECTION VIII - PIPING ONLY

6" s/120 - 0.562" Wall

PENETRAMETER SELECTIONNote: Esn. Wire: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Hole 20 S/S Wire: 0.016 Esn Wire: B4 F/S Hole: 17 F/S Wire: 0.013 Esn Wire: B5Reinforced welds welded fromone side: S/S Hole: 20 S/S Wire: 0.016 Esn. Wire: B4

F/S Hole: 17 S/S Wire: 0.013 Esn. Wire: B5Reinforced welds welded fromtwo sides: S/S Hole: 25 S/S Wire: 0.020 Esn. Wire: B3

F/S Hole: 20 S/S Wire: 0.016 Esn. Wire: B4

Maximum allowable reinforcement if welded from one side: 0.188" Total of Wall + Reinforcement 0.750"Maximum allowable reinforcement if welded from two sides: 0.375" Total of Wall + Reinforcement 0.937"

PENETRAMETER SELECTION FOR API 620, 650, & 653Welds without reinforcement: Same as aboveWelds with reinforcement: S/S Hole: 20 S/S Wire: 0.016 Esn. Wire: B4

F/S Hole: 17 F/S Wire: 0.013 Esn. Wire: B5

Maximum allowable reinforcement: 0.094" Total of Wall + Reinforcement 0.656"

UW-51; API 620, 650, & 653Cracks, Incomplete Penetration, and Incomplete Fusion: None AllowedOther Elongated Indications (UW-51 only):Max Length of other elongated indications: 0.250"Max Cumulative length of aligned indications is 0.562" in a length of weld equal to 6.744" unlessseperated by the length of 6L Rounded Indications (UW-51 Only):Relevant Indications: 0.031Max Size of Random Indications: 0.141" Max Size of Isolated Rounded Indications: 0.187"Max sum of diameters of Aligned Rounded Indications: 0.562" in a 6.744" length of weldMax group length of Aligned Rounded Indications: 0.250"Max group length of Cluster Rounded Indications if 1 group is present in a 6" length of weld: 1.0"Max group length of Cluster Rounded Indications if more than 1 group is present in a 6" length of weld: 1.0"

UW-52Cracks, Incomplete Penetration, and Incomplete Fusion:Slag Inclusions:Max Size of slag inclusions: 0.375"Max Cumulative length of acceptable in-line indications (other than rounded): 0.562" in a 3.372" length ofwelds and must be seperated by the length of 3L of acceptable weld metal.

Technique Sheet Info (Source Side of Object to Film and Source Distances)Reinforcement is found in the applicable penetrameter selection boxes above.

Source to Source Side of Object distance; DWE/DWV 6.063" Panoramic: 2.751"Source Side of Object to Film Distance: 0.562"

Page 357: NDT Code Book Made Easy

S

ASME SECTION VIII - PIPING ONLY

6" s/160 - 0.719" Wall

PENETRAMETER SELECTIONNote: Esn. Wire: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Hole 20 S/S Wire: 0.016 Esn Wire: B4 F/S Hole: 17 F/S Wire: 0.013 Esn Wire: B5Reinforced welds welded fromone side: S/S Hole: 25 S/S Wire: 0.020 Esn. Wire: B3

F/S Hole: 20 S/S Wire: 0.016 Esn. Wire: B4Reinforced welds welded fromtwo sides: S/S Hole: 30 S/S Wire: 0.025 Esn. Wire: B2

F/S Hole: 25 S/S Wire: 0.020 Esn. Wire: B3

Maximum allowable reinforcement if welded from one side: 0.188" Total of Wall + Reinforcement 0.907"Maximum allowable reinforcement if welded from two sides: 0.375" Total of Wall + Reinforcement 1.094"

PENETRAMETER SELECTION FOR API 620, 650, & 653Welds without reinforcement: Same as aboveWelds with reinforcement: S/S Hole: 25 S/S Wire: 0.020 Esn. Wire: B3

F/S Hole: 20 F/S Wire: 0.016 Esn. Wire: B4

Maximum allowable reinforcement: 0.094" Total of Wall + Reinforcement 0.813"

UW-51; API 620, 650, & 653Cracks, Incomplete Penetration, and Incomplete Fusion: None AllowedOther Elongated Indications (UW-51 only):Max Length of other elongated indications: 0.250"Max Cumulative length of aligned indications is 0.719" in a length of weld equal to 8.628" unlessseperated by the length of 6L Rounded Indications (UW-51 Only):Relevant Indications: 0.031Max Size of Random Indications: 0.156" Max Size of Isolated Rounded Indications: 0.240"Max sum of diameters of Aligned Rounded Indications: 0.719" in a 8.628" length of weldMax group length of Aligned Rounded Indications: 0.250"Max group length of Cluster Rounded Indications if 1 group is present in a 6" length of weld: 1.0"Max group length of Cluster Rounded Indications if more than 1 group is present in a 6" length of weld: 1.0"

UW-52Cracks, Incomplete Penetration, and Incomplete Fusion:Slag Inclusions:Max Size of slag inclusions: 0.480"Max Cumulative length of acceptable in-line indications (other than rounded): 0.719" in a 4.314" length ofwelds and must be seperated by the length of 3L of acceptable weld metal.

Technique Sheet Info (Source Side of Object to Film and Source Distances)Reinforcement is found in the applicable penetrameter selection boxes above.

Source to Source Side of Object distance; DWE/DWV 5.906" Panoramic: 2.594"Source Side of Object to Film Distance: 0.719"

Page 358: NDT Code Book Made Easy

S

ASME SECTION VIII - PIPING ONLY

6" XX Strong - 0.864" Wall

PENETRAMETER SELECTIONNote: Esn. Wire: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Hole 25 S/S Wire: 0.020 Esn Wire: B3 F/S Hole: 20 F/S Wire: 0.016 Esn Wire: B4Reinforced welds welded fromone side: S/S Hole: 30 S/S Wire: 0.025 Esn. Wire: B2

F/S Hole: 25 S/S Wire: 0.020 Esn. Wire: B3Reinforced welds welded fromtwo sides: S/S Hole: 30 S/S Wire: 0.025 Esn. Wire: B2

F/S Hole: 25 S/S Wire: 0.020 Esn. Wire: B3

Maximum allowable reinforcement if welded from one side: 0.188" Total of Wall + Reinforcement 1.052"Maximum allowable reinforcement if welded from two sides: 0.375" Total of Wall + Reinforcement 1.239"

PENETRAMETER SELECTION FOR API 620, 650, & 653Welds without reinforcement: Same as aboveWelds with reinforcement: S/S Hole: 25 S/S Wire: 0.020 Esn. Wire: B3

F/S Hole: 20 F/S Wire: 0.016 Esn. Wire: B4

Maximum allowable reinforcement: 0.094" Total of Wall + Reinforcement 0.958"

UW-51; API 620, 650, & 653Cracks, Incomplete Penetration, and Incomplete Fusion: None AllowedOther Elongated Indications (UW-51 only):Max Length of other elongated indications: 0.288"Max Cumulative length of aligned indications is 0.864" in a length of weld equal to 10.368" unlessseperated by the length of 6L Rounded Indications (UW-51 Only):Relevant Indications: 0.031Max Size of Random Indications: 0.156" Max Size of Isolated Rounded Indications: 0.250"Max sum of diameters of Aligned Rounded Indications: 0.864" in a 10.368" length of weldMax group length of Aligned Rounded Indications: 0.288"Max group length of Cluster Rounded Indications if 1 group is present in a 6" length of weld: 1.0"Max group length of Cluster Rounded Indications if more than 1 group is present in a 6" length of weld: 1.0"

UW-52Cracks, Incomplete Penetration, and Incomplete Fusion:Slag Inclusions:Max Size of slag inclusions: 0.576"Max Cumulative length of acceptable in-line indications (other than rounded): 0.864" in a 5.184" length ofwelds and must be seperated by the length of 3L of acceptable weld metal.

Technique Sheet Info (Source Side of Object to Film and Source Distances)Reinforcement is found in the applicable penetrameter selection boxes above.

Source to Source Side of Object distance; DWE/DWV 5.761" Panoramic: 2.449"Source Side of Object to Film Distance: 0.864"

Page 359: NDT Code Book Made Easy

S

ASME SECTION VIII - PIPING ONLY

8" s/10 - 0.148" Wall

PENETRAMETER SELECTIONNote: Esn. Wire: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Hole 12 S/S Wire: 0.008 Esn Wire: A2 F/S Hole: 10 F/S Wire: 0.006 Esn Wire: A3Reinforced welds welded fromone side: S/S Hole: 15 S/S Wire: 0.010 Esn. Wire: A1 or B6

F/S Hole: 12 S/S Wire: 0.008 Esn. Wire: A2Reinforced welds welded fromtwo sides: S/S Hole: 17 S/S Wire: 0.013 Esn. Wire: B5

F/S Hole: 15 S/S Wire: 0.010 Esn. Wire: A1 or B6

Maximum allowable reinforcement if welded from one side: 0.125" Total of Wall + Reinforcement 0.273"Maximum allowable reinforcement if welded from two sides: 0.250" Total of Wall + Reinforcement 0.398"

PENETRAMETER SELECTION FOR API 620, 650, & 653Welds without reinforcement: Same as aboveWelds with reinforcement: S/S Hole: 12 S/S Wire: 0.008 Esn. Wire: A2

F/S Hole: 10 F/S Wire: 0.006 Esn. Wire: A3

Maximum allowable reinforcement: 0.0625" Total of Wall + Reinforcement 0.211"

UW-51; API 620, 650, & 653Cracks, Incomplete Penetration, and Incomplete Fusion: None AllowedOther Elongated Indications (UW-51 only):Max Length of other elongated indications: 0.250"Max Cumulative length of aligned indications is 0.148" in a length of weld equal to 1.776" unlessseperated by the length of 6L Rounded Indications (UW-51 Only):Relevant Indications: 0.016Max Size of Random Indications: 0.037" Max Size of Isolated Rounded Indications: 0.049"Max sum of diameters of Aligned Rounded Indications: 0.148" in a 1.776" length of weldMax group length of Aligned Rounded Indications: 0.250"Max group length of Cluster Rounded Indications if 1 group is present in a 6" length of weld: 0.296"Max group length of Cluster Rounded Indications if more than 1 group is present in a 6" length of weld: 1.0"

UW-52Cracks, Incomplete Penetration, and Incomplete Fusion:Slag Inclusions:Max Size of slag inclusions: 0.250"Max Cumulative length of acceptable in-line indications (other than rounded): 0.148" in a 0.888" length ofwelds and must be seperated by the length of 3L of acceptable weld metal.

Technique Sheet Info (Source Side of Object to Film and Source Distances)Reinforcement is found in the applicable penetrameter selection boxes above.

Source to Source Side of Object distance; DWE/DWV 8.447" Panoramic: 4.165"Source Side of Object to Film Distance: 0.148"

Page 360: NDT Code Book Made Easy

S

ASME SECTION VIII - PIPING ONLY

8" s/40 & Std. - 0.322" Wall

PENETRAMETER SELECTIONNote: Esn. Wire: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Hole 15 S/S Wire: 0.010 Esn Wire: A1 or B6 F/S Hole: 12 F/S Wire: 0.008 Esn Wire: A2Reinforced welds welded fromone side: S/S Hole: 17 S/S Wire: 0.013 Esn. Wire: B5

F/S Hole: 15 S/S Wire: 0.010 Esn. Wire: A1 or B6Reinforced welds welded fromtwo sides: S/S Hole: 20 S/S Wire: 0.016 Esn. Wire: B4

F/S Hole: 17 S/S Wire: 0.013 Esn. Wire: B5

Maximum allowable reinforcement if welded from one side: 0.156" Total of Wall + Reinforcement 0.478"Maximum allowable reinforcement if welded from two sides: 0.312" Total of Wall + Reinforcement 0.634"

PENETRAMETER SELECTION FOR API 620, 650, & 653Welds without reinforcement: Same as aboveWelds with reinforcement: S/S Hole: 17 S/S Wire: 0.013 Esn. Wire: B5

F/S Hole: 15 F/S Wire: 0.010 Esn. Wire: A1 or B6

Maximum allowable reinforcement: 0.0625" Total of Wall + Reinforcement 0.385"

UW-51; API 620, 650, & 653Cracks, Incomplete Penetration, and Incomplete Fusion: None AllowedOther Elongated Indications (UW-51 only):Max Length of other elongated indications: 0.250"Max Cumulative length of aligned indications is 0.322" in a length of weld equal to 3.864" unlessseperated by the length of 6L Rounded Indications (UW-51 Only):Relevant Indications: 0.031"Max Size of Random Indications: 0.081" Max Size of Isolated Rounded Indications: 0.107"Max sum of diameters of Aligned Rounded Indications: 0.322" in a 3.864" length of weldMax group length of Aligned Rounded Indications: 0.250"Max group length of Cluster Rounded Indications if 1 group is present in a 6" length of weld: 0.644"Max group length of Cluster Rounded Indications if more than 1 group is present in a 6" length of weld: 1.0"

UW-52Cracks, Incomplete Penetration, and Incomplete Fusion:Slag Inclusions:Max Size of slag inclusions: 0.250"Max Cumulative length of acceptable in-line indications (other than rounded): 0.322" in a 1.932" length ofwelds and must be seperated by the length of 3L of acceptable weld metal.

Technique Sheet Info (Source Side of Object to Film and Source Distances)Reinforcement is found in the applicable penetrameter selection boxes above.

Source to Source Side of Object distance; DWE/DWV 8.303" Panoramic: 3.991"Source Side of Object to Film Distance: 0.322"

Page 361: NDT Code Book Made Easy

S

ASME SECTION VIII - PIPING ONLY

8" s/80 & Extra Strong - 0.500" Wall

PENETRAMETER SELECTIONNote: Esn. Wire: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Hole 17 S/S Wire: 0.013 Esn Wire: B5 F/S Hole: 15 F/S Wire: 0.010 Esn Wire: A1 or B6Reinforced welds welded fromone side: S/S Hole: 20 S/S Wire: 0.016 Esn. Wire: B4

F/S Hole: 17 S/S Wire: 0.013 Esn. Wire: B5Reinforced welds welded fromtwo sides: S/S Hole: 25 S/S Wire: 0.020 Esn. Wire: B3

F/S Hole: 20 S/S Wire: 0.016 Esn. Wire: B4

Maximum allowable reinforcement if welded from one side: 0.156" Total of Wall + Reinforcement 0.656"Maximum allowable reinforcement if welded from two sides: 0.312" Total of Wall + Reinforcement 0.812"

PENETRAMETER SELECTION FOR API 620, 650, & 653Welds without reinforcement: Same as aboveWelds with reinforcement: S/S Hole: 20 S/S Wire: 0.016 Esn. Wire: B4

F/S Hole: 17 F/S Wire: 0.013 Esn. Wire: B5

Maximum allowable reinforcement: 0.0625" Total of Wall + Reinforcement 0.563"

UW-51; API 620, 650, & 653Cracks, Incomplete Penetration, and Incomplete Fusion: None AllowedOther Elongated Indications (UW-51 only):Max Length of other elongated indications: 0.250"Max Cumulative length of aligned indications is 0.500" in a length of weld equal to 6.00" unlessseperated by the length of 6L Rounded Indications (UW-51 Only):Relevant Indications: 0.031"Max Size of Random Indications: 0.125" Max Size of Isolated Rounded Indications: 0.167"Max sum of diameters of Aligned Rounded Indications: 0.500" in a 6.00" length of weldMax group length of Aligned Rounded Indications: 0.250"Max group length of Cluster Rounded Indications if 1 group is present in a 6" length of weld: 1.0"Max group length of Cluster Rounded Indications if more than 1 group is present in a 6" length of weld: 1.0"

UW-52Cracks, Incomplete Penetration, and Incomplete Fusion:Slag Inclusions:Max Size of slag inclusions: 0.334"Max Cumulative length of acceptable in-line indications (other than rounded): 0.500" in a 3.00" length ofwelds and must be seperated by the length of 3L of acceptable weld metal.

Technique Sheet Info (Source Side of Object to Film and Source Distances)Reinforcement is found in the applicable penetrameter selection boxes above.

Source to Source Side of Object distance; DWE/DWV 8.125" Panoramic: 3.813"Source Side of Object to Film Distance: 0.500"

Page 362: NDT Code Book Made Easy

S

ASME SECTION VIII - PIPING ONLY

8" s/120 - 0.719" Wall

PENETRAMETER SELECTIONNote: Esn. Wire: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Hole 20 S/S Wire: 0.016 Esn Wire: B4 F/S Hole: 17 F/S Wire: 0.013 Esn Wire: B5Reinforced welds welded fromone side: S/S Hole: 25 S/S Wire: 0.020 Esn. Wire: B3

F/S Hole: 20 S/S Wire: 0.016 Esn. Wire: B4Reinforced welds welded fromtwo sides: S/S Hole: 30 S/S Wire: 0.025 Esn. Wire: B2

F/S Hole: 25 S/S Wire: 0.020 Esn. Wire: B3

Maximum allowable reinforcement if welded from one side: 0.188" Total of Wall + Reinforcement 0.907"Maximum allowable reinforcement if welded from two sides: 0.375" Total of Wall + Reinforcement 1.094"

PENETRAMETER SELECTION FOR API 620, 650, & 653Welds without reinforcement: Same as aboveWelds with reinforcement: S/S Hole: 25 S/S Wire: 0.020 Esn. Wire: B3

F/S Hole: 20 F/S Wire: 0.016 Esn. Wire: B4

Maximum allowable reinforcement: 0.094" Total of Wall + Reinforcement 0.813"

UW-51; API 620, 650, & 653Cracks, Incomplete Penetration, and Incomplete Fusion: None AllowedOther Elongated Indications (UW-51 only):Max Length of other elongated indications: 0.250"Max Cumulative length of aligned indications is 0.719" in a length of weld equal to 8.628" unlessseperated by the length of 6L Rounded Indications (UW-51 Only):Relevant Indications: 0.031"Max Size of Random Indications: 0.156" Max Size of Isolated Rounded Indications: 0.240"Max sum of diameters of Aligned Rounded Indications: 0.719" in a 8.628" length of weldMax group length of Aligned Rounded Indications: 0.250"Max group length of Cluster Rounded Indications if 1 group is present in a 6" length of weld: 1.0"Max group length of Cluster Rounded Indications if more than 1 group is present in a 6" length of weld: 1.0"

UW-52Cracks, Incomplete Penetration, and Incomplete Fusion:Slag Inclusions:Max Size of slag inclusions: 0.480"Max Cumulative length of acceptable in-line indications (other than rounded): 0.719" in a 4.314" length ofwelds and must be seperated by the length of 3L of acceptable weld metal.

Technique Sheet Info (Source Side of Object to Film and Source Distances)Reinforcement is found in the applicable penetrameter selection boxes above.

Source to Source Side of Object distance; DWE/DWV 7.906" Panoramic: 3.594"Source Side of Object to Film Distance: 0.719"

Page 363: NDT Code Book Made Easy

S

ASME SECTION VIII - PIPING ONLY

8" s/160" - 0.906" Wall

PENETRAMETER SELECTIONNote: Esn. Wire: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Hole 25 S/S Wire: 0.020 Esn Wire: B3 F/S Hole: 20 F/S Wire: 0.016 Esn Wire: B4Reinforced welds welded fromone side: S/S Hole: 30 S/S Wire: 0.025 Esn. Wire: B2

F/S Hole: 25 S/S Wire: 0.020 Esn. Wire: B3Reinforced welds welded fromtwo sides: S/S Hole: 30 S/S Wire: 0.025 Esn. Wire: B2

F/S Hole: 25 S/S Wire: 0.020 Esn. Wire: B3

Maximum allowable reinforcement if welded from one side: 0.188" Total of Wall + Reinforcement 1.094"Maximum allowable reinforcement if welded from two sides: 0.375" Total of Wall + Reinforcement 1.281"

PENETRAMETER SELECTION FOR API 620, 650, & 653Welds without reinforcement: Same as aboveWelds with reinforcement: S/S Hole: 25 S/S Wire: 0.020 Esn. Wire: B3

F/S Hole: 20 F/S Wire: 0.016 Esn. Wire: B4

Maximum allowable reinforcement: 0.094" Total of Wall + Reinforcement 1.00"

UW-51; API 620, 650, & 653Cracks, Incomplete Penetration, and Incomplete Fusion: None AllowedOther Elongated Indications (UW-51 only):Max Length of other elongated indications: 0.302"Max Cumulative length of aligned indications is 0.906" in a length of weld equal to 10.872" unlessseperated by the length of 6L Rounded Indications (UW-51 Only):Relevant Indications: 0.031"Max Size of Random Indications: 0.156" Max Size of Isolated Rounded Indications: 0.250"Max sum of diameters of Aligned Rounded Indications: 0.906" in a 10.872" length of weldMax group length of Aligned Rounded Indications: 0.302"Max group length of Cluster Rounded Indications if 1 group is present in a 6" length of weld: 1.0"Max group length of Cluster Rounded Indications if more than 1 group is present in a 6" length of weld: 1.0"

UW-52Cracks, Incomplete Penetration, and Incomplete Fusion:Slag Inclusions:Max Size of slag inclusions: 0.604"Max Cumulative length of acceptable in-line indications (other than rounded): 0.906" in a 5.436" length ofwelds and must be seperated by the length of 3L of acceptable weld metal.

Technique Sheet Info (Source Side of Object to Film and Source Distances)Reinforcement is found in the applicable penetrameter selection boxes above.

Source to Source Side of Object distance; DWE/DWV 7.719" Panoramic: 3.407"Source Side of Object to Film Distance: 0.906"

Page 364: NDT Code Book Made Easy

S

ASME SECTION VIII - PIPING ONLY

8" XX Strong - 0.875" Wall

PENETRAMETER SELECTIONNote: Esn. Wire: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Hole 25 S/S Wire: 0.020 Esn Wire: B3 F/S Hole: 20 F/S Wire: 0.016 Esn Wire: B4Reinforced welds welded fromone side: S/S Hole: 30 S/S Wire: 0.025 Esn. Wire: B2

F/S Hole: 25 S/S Wire: 0.020 Esn. Wire: B3Reinforced welds welded fromtwo sides: S/S Hole: 30 S/S Wire: 0.025 Esn. Wire: B2

F/S Hole: 25 S/S Wire: 0.020 Esn. Wire: B3

Maximum allowable reinforcement if welded from one side: 0.188" Total of Wall + Reinforcement 1.063"Maximum allowable reinforcement if welded from two sides: 0.375" Total of Wall + Reinforcement 1.250"

PENETRAMETER SELECTION FOR API 620, 650, & 653Welds without reinforcement: Same as aboveWelds with reinforcement: S/S Hole: 25 S/S Wire: 0.020 Esn. Wire: B3

F/S Hole: 20 F/S Wire: 0.016 Esn. Wire: B4

Maximum allowable reinforcement: 0.094" Total of Wall + Reinforcement 0.969"

UW-51; API 620, 650, & 653Cracks, Incomplete Penetration, and Incomplete Fusion: None AllowedOther Elongated Indications (UW-51 only):Max Length of other elongated indications: 0.292"Max Cumulative length of aligned indications is 0.875" in a length of weld equal to 10.5" unlessseperated by the length of 6L Rounded Indications (UW-51 Only):Relevant Indications: 0.031"Max Size of Random Indications: 0.156" Max Size of Isolated Rounded Indications: 0.250"Max sum of diameters of Aligned Rounded Indications: 0.875" in a 10.5" length of weldMax group length of Aligned Rounded Indications: 0.292"Max group length of Cluster Rounded Indications if 1 group is present in a 6" length of weld: 1.0"Max group length of Cluster Rounded Indications if more than 1 group is present in a 6" length of weld: 1.0"

UW-52Cracks, Incomplete Penetration, and Incomplete Fusion:Slag Inclusions:Max Size of slag inclusions: 0.584"Max Cumulative length of acceptable in-line indications (other than rounded): 0.875" in a 5.250" length ofwelds and must be seperated by the length of 3L of acceptable weld metal.

Technique Sheet Info (Source Side of Object to Film and Source Distances)Reinforcement is found in the applicable penetrameter selection boxes above.

Source to Source Side of Object distance; DWE/DWV 7.750" Panoramic: 3.438"Source Side of Object to Film Distance: 0.875"

Page 365: NDT Code Book Made Easy

S

ASME SECTION VIII - PIPING ONLY

10" s/10 - 0.165" Wall

PENETRAMETER SELECTIONNote: Esn. Wire: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Hole 12 S/S Wire: 0.008 Esn Wire: A2 F/S Hole: 10 F/S Wire: 0.006 Esn Wire: A3Reinforced welds welded fromone side: S/S Hole: 15 S/S Wire: 0.010 Esn. Wire: A1 or B6

F/S Hole: 12 S/S Wire: 0.008 Esn. Wire: A2Reinforced welds welded fromtwo sides: S/S Hole: 17 S/S Wire: 0.013 Esn. Wire: B5

F/S Hole: 15 S/S Wire: 0.010 Esn. Wire: A1 or B6

Maximum allowable reinforcement if welded from one side: 0.125" Total of Wall + Reinforcement 0.290"Maximum allowable reinforcement if welded from two sides: 0.250" Total of Wall + Reinforcement 0.415"

PENETRAMETER SELECTION FOR API 620, 650, & 653Welds without reinforcement: Same as aboveWelds with reinforcement: S/S Hole: 12 S/S Wire: 0.008 Esn. Wire: A2

F/S Hole: 10 F/S Wire: 0.006 Esn. Wire: A3

Maximum allowable reinforcement: 0.0625" Total of Wall + Reinforcement 0.228"

UW-51; API 620, 650, & 653Cracks, Incomplete Penetration, and Incomplete Fusion: None AllowedOther Elongated Indications (UW-51 only):Max Length of other elongated indications: 0.250"Max Cumulative length of aligned indications is 0.165" in a length of weld equal to 1.980" unlessseperated by the length of 6L Rounded Indications (UW-51 Only):Relevant Indications: 0.016Max Size of Random Indications: 0.041" Max Size of Isolated Rounded Indications: 0.055"Max sum of diameters of Aligned Rounded Indications: 0.165" in a 1.980" length of weldMax group length of Aligned Rounded Indications: 0.250"Max group length of Cluster Rounded Indications if 1 group is present in a 6" length of weld: 0.330"Max group length of Cluster Rounded Indications if more than 1 group is present in a 6" length of weld: 1.0"

UW-52Cracks, Incomplete Penetration, and Incomplete Fusion:Slag Inclusions:Max Size of slag inclusions: 0.250"Max Cumulative length of acceptable in-line indications (other than rounded): 0.165" in a 0.990" length ofwelds and must be seperated by the length of 3L of acceptable weld metal.

Technique Sheet Info (Source Side of Object to Film and Source Distances)Reinforcement is found in the applicable penetrameter selection boxes above.

Source to Source Side of Object distance; DWE/DWV 10.585" Panoramic: 5.210"Source Side of Object to Film Distance: 0.165"

Page 366: NDT Code Book Made Easy

S

ASME SECTION VIII - PIPING ONLY

10" s/40 & Std. - 0.365" Wall

PENETRAMETER SELECTIONNote: Esn. Wire: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Hole 15 S/S Wire: 0.010 Esn Wire: A1 or B6 F/S Hole: 12 F/S Wire: 0.008 Esn Wire: A2Reinforced welds welded fromone side: S/S Hole: 20 S/S Wire: 0.016 Esn. Wire: B4

F/S Hole: 17 S/S Wire: 0.013 Esn. Wire: B5Reinforced welds welded fromtwo sides: S/S Hole: 20 S/S Wire: 0.016 Esn. Wire: B4

F/S Hole: 17 S/S Wire: 0.013 Esn. Wire: B5

Maximum allowable reinforcement if welded from one side: 0.156" Total of Wall + Reinforcement 0.521"Maximum allowable reinforcement if welded from two sides: 0.312" Total of Wall + Reinforcement 0.677"

PENETRAMETER SELECTION FOR API 620, 650, & 653Welds without reinforcement: Same as aboveWelds with reinforcement: S/S Hole: 17 S/S Wire: 0.013 Esn. Wire: B5

F/S Hole: 15 F/S Wire: 0.010 Esn. Wire: A1 or B6

Maximum allowable reinforcement: 0.0625" Total of Wall + Reinforcement 0.428"

UW-51; API 620, 650, & 653Cracks, Incomplete Penetration, and Incomplete Fusion: None AllowedOther Elongated Indications (UW-51 only):Max Length of other elongated indications: 0.250"Max Cumulative length of aligned indications is 0.365" in a length of weld equal to 4.380" unlessseperated by the length of 6L Rounded Indications (UW-51 Only):Relevant Indications: 0.031Max Size of Random Indications: 0.091" Max Size of Isolated Rounded Indications: 0.122"Max sum of diameters of Aligned Rounded Indications: 0.365" in a 4.380" length of weldMax group length of Aligned Rounded Indications: 0.250"Max group length of Cluster Rounded Indications if 1 group is present in a 6" length of weld: 0.730"Max group length of Cluster Rounded Indications if more than 1 group is present in a 6" length of weld: 1.0"

UW-52Cracks, Incomplete Penetration, and Incomplete Fusion:Slag Inclusions:Max Size of slag inclusions: 0.250"Max Cumulative length of acceptable in-line indications (other than rounded): 0.365" in a 2.190" length ofwelds and must be seperated by the length of 3L of acceptable weld metal.

Technique Sheet Info (Source Side of Object to Film and Source Distances)Reinforcement is found in the applicable penetrameter selection boxes above.

Source to Source Side of Object distance; DWE/DWV 10.385" Panoramic: 5.010"Source Side of Object to Film Distance: 0.365"

Page 367: NDT Code Book Made Easy

S

ASME SECTION VIII - PIPING ONLY

10" Extra Strong - 0.500" Wall

PENETRAMETER SELECTIONNote: Esn. Wire: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Hole 17 S/S Wire: 0.013 Esn Wire: B5 F/S Hole: 15 F/S Wire: 0.010 Esn Wire: A1 or B6Reinforced welds welded fromone side: S/S Hole: 20 S/S Wire: 0.016 Esn. Wire: B4

F/S Hole: 17 S/S Wire: 0.013 Esn. Wire: B5Reinforced welds welded fromtwo sides: S/S Hole: 25 S/S Wire: 0.020 Esn. Wire: B3

F/S Hole: 20 S/S Wire: 0.016 Esn. Wire: B4

Maximum allowable reinforcement if welded from one side: 0.156" Total of Wall + Reinforcement 0.656"Maximum allowable reinforcement if welded from two sides: 0.312" Total of Wall + Reinforcement 0.812"

PENETRAMETER SELECTION FOR API 620, 650, & 653Welds without reinforcement: Same as aboveWelds with reinforcement: S/S Hole: 20 S/S Wire: 0.016 Esn. Wire: B4

F/S Hole: 17 F/S Wire: 0.013 Esn. Wire: B5

Maximum allowable reinforcement: 0.0625" Total of Wall + Reinforcement 0.563"

UW-51; API 620, 650, & 653Cracks, Incomplete Penetration, and Incomplete Fusion: None AllowedOther Elongated Indications (UW-51 only):Max Length of other elongated indications: 0.250"Max Cumulative length of aligned indications is 0.500" in a length of weld equal to 6.00" unlessseperated by the length of 6L Rounded Indications (UW-51 Only):Relevant Indications: 0.031"Max Size of Random Indications: 0.125" Max Size of Isolated Rounded Indications: 0.167"Max sum of diameters of Aligned Rounded Indications: 0.500" in a 6.00" length of weldMax group length of Aligned Rounded Indications: 0.250"Max group length of Cluster Rounded Indications if 1 group is present in a 6" length of weld: 1.0"Max group length of Cluster Rounded Indications if more than 1 group is present in a 6" length of weld: 1.0"

UW-52Cracks, Incomplete Penetration, and Incomplete Fusion:Slag Inclusions:Max Size of slag inclusions: 0.334"Max Cumulative length of acceptable in-line indications (other than rounded): 0.500" in a 3.00" length ofwelds and must be seperated by the length of 3L of acceptable weld metal.

Technique Sheet Info (Source Side of Object to Film and Source Distances)Reinforcement is found in the applicable penetrameter selection boxes above.

Source to Source Side of Object distance; DWE/DWV 10.250" Panoramic: 4.875"Source Side of Object to Film Distance: 0.500"

Page 368: NDT Code Book Made Easy

S

ASME SECTION VIII - PIPING ONLY

10" s/80 - 0.594" Wall

PENETRAMETER SELECTIONNote: Esn. Wire: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Hole 20 S/S Wire: 0.016 Esn Wire: B4 F/S Hole: 17 F/S Wire: 0.013 Esn Wire: B5Reinforced welds welded fromone side: S/S Hole: 25 S/S Wire: 0.020 Esn. Wire: B3

F/S Hole: 20 S/S Wire: 0.016 Esn. Wire: B4Reinforced welds welded fromtwo sides: S/S Hole: 25 S/S Wire: 0.020 Esn. Wire: B3

F/S Hole: 20 S/S Wire: 0.016 Esn. Wire: B4

Maximum allowable reinforcement if welded from one side: 0.188" Total of Wall + Reinforcement 0.782"Maximum allowable reinforcement if welded from two sides: 0.375" Total of Wall + Reinforcement 0.969"

PENETRAMETER SELECTION FOR API 620, 650, & 653Welds without reinforcement: Same as aboveWelds with reinforcement: S/S Hole: 20 S/S Wire: 0.016 Esn. Wire: B4

F/S Hole: 17 F/S Wire: 0.013 Esn. Wire: B5

Maximum allowable reinforcement: 0.094" Total of Wall + Reinforcement 0.688"

UW-51; API 620, 650, & 653Cracks, Incomplete Penetration, and Incomplete Fusion: None AllowedOther Elongated Indications (UW-51 only):Max Length of other elongated indications: 0.250"Max Cumulative length of aligned indications is 0.594" in a length of weld equal to 7.128" unlessseperated by the length of 6L Rounded Indications (UW-51 Only):Relevant Indications: 0.031"Max Size of Random Indications: 0.149" Max Size of Isolated Rounded Indications: 0.198"Max sum of diameters of Aligned Rounded Indications: 0.594" in a 7.128" length of weldMax group length of Aligned Rounded Indications: 0.250"Max group length of Cluster Rounded Indications if 1 group is present in a 6" length of weld: 1.0"Max group length of Cluster Rounded Indications if more than 1 group is present in a 6" length of weld: 1.0"

UW-52Cracks, Incomplete Penetration, and Incomplete Fusion:Slag Inclusions:Max Size of slag inclusions: 0.396"Max Cumulative length of acceptable in-line indications (other than rounded): 0.594" in a 3.564" length ofwelds and must be seperated by the length of 3L of acceptable weld metal.

Technique Sheet Info (Source Side of Object to Film and Source Distances)Reinforcement is found in the applicable penetrameter selection boxes above.

Source to Source Side of Object distance; DWE/DWV 10.156" Panoramic: 4.781"Source Side of Object to Film Distance: 0.594"

Page 369: NDT Code Book Made Easy

S

ASME SECTION VIII - PIPING ONLY

10" s/120 - 0.844" Wall

PENETRAMETER SELECTIONNote: Esn. Wire: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Hole 25 S/S Wire: 0.020 Esn Wire: B3 F/S Hole: 20 F/S Wire: 0.016 Esn Wire: B4Reinforced welds welded fromone side: S/S Hole: 30 S/S Wire: 0.025 Esn. Wire: B2

F/S Hole: 25 S/S Wire: 0.020 Esn. Wire: B3Reinforced welds welded fromtwo sides: S/S Hole: 30 S/S Wire: 0.025 Esn. Wire: B2

F/S Hole: 25 S/S Wire: 0.020 Esn. Wire: B3

Maximum allowable reinforcement if welded from one side: 0.188" Total of Wall + Reinforcement 1.032"Maximum allowable reinforcement if welded from two sides: 0.375" Total of Wall + Reinforcement 1.219"

PENETRAMETER SELECTION FOR API 620, 650, & 653Welds without reinforcement: Same as aboveWelds with reinforcement: S/S Hole: 25 S/S Wire: 0.020 Esn. Wire: B3

F/S Hole: 20 F/S Wire: 0.016 Esn. Wire: B4

Maximum allowable reinforcement: 0.094" Total of Wall + Reinforcement 0.938"

UW-51; API 620, 650, & 653Cracks, Incomplete Penetration, and Incomplete Fusion: None AllowedOther Elongated Indications (UW-51 only):Max Length of other elongated indications: 0.281"Max Cumulative length of aligned indications is 0.844" in a length of weld equal to 10.128" unlessseperated by the length of 6L Rounded Indications (UW-51 Only):Relevant Indications: 0.031"Max Size of Random Indications: 0.156" Max Size of Isolated Rounded Indications: 0.250"Max sum of diameters of Aligned Rounded Indications: 0.844" in a 10.128" length of weldMax group length of Aligned Rounded Indications: 0.281"Max group length of Cluster Rounded Indications if 1 group is present in a 6" length of weld: 1.0"Max group length of Cluster Rounded Indications if more than 1 group is present in a 6" length of weld: 1.0"

UW-52Cracks, Incomplete Penetration, and Incomplete Fusion:Slag Inclusions:Max Size of slag inclusions: 0.563"Max Cumulative length of acceptable in-line indications (other than rounded): 0.844" in a 5.064" length ofwelds and must be seperated by the length of 3L of acceptable weld metal.

Technique Sheet Info (Source Side of Object to Film and Source Distances)Reinforcement is found in the applicable penetrameter selection boxes above.

Source to Source Side of Object distance; DWE/DWV 9.906" Panoramic: 4.531"Source Side of Object to Film Distance: 0.844"

Page 370: NDT Code Book Made Easy

S

ASME SECTION VIII - PIPING ONLY

10" XX Strong - 1.00" Wall

PENETRAMETER SELECTIONNote: Esn. Wire: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Hole 25 S/S Wire: 0.020 Esn Wire: B3 F/S Hole: 20 F/S Wire: 0.016 Esn Wire: B4Reinforced welds welded fromone side: S/S Hole: 30 S/S Wire: 0.025 Esn. Wire: B2

F/S Hole: 25 S/S Wire: 0.020 Esn. Wire: B3Reinforced welds welded fromtwo sides: S/S Hole: 30 S/S Wire: 0.025 Esn. Wire: B2

F/S Hole: 25 S/S Wire: 0.020 Esn. Wire: B3

Maximum allowable reinforcement if welded from one side: 0.188" Total of Wall + Reinforcement 1.188"Maximum allowable reinforcement if welded from two sides: 0.375" Total of Wall + Reinforcement 1.375"

PENETRAMETER SELECTION FOR API 620, 650, & 653Welds without reinforcement: Same as aboveWelds with reinforcement: S/S Hole: 30 S/S Wire: 0.025 Esn. Wire: B2

F/S Hole: 25 F/S Wire: 0.020 Esn. Wire: B3

Maximum allowable reinforcement: 0.094" Total of Wall + Reinforcement 1.094"

UW-51; API 620, 650, & 653Cracks, Incomplete Penetration, and Incomplete Fusion: None AllowedOther Elongated Indications (UW-51 only):Max Length of other elongated indications: 0.333"Max Cumulative length of aligned indications is 1.00" in a length of weld equal to 12.00" unlessseperated by the length of 6L Rounded Indications (UW-51 Only):Relevant Indications: 0.031"Max Size of Random Indications: 0.156" Max Size of Isolated Rounded Indications: 0.250"Max sum of diameters of Aligned Rounded Indications: 1.00" in a 12.00" length of weldMax group length of Aligned Rounded Indications: 0.333"Max group length of Cluster Rounded Indications if 1 group is present in a 6" length of weld: 1.0"Max group length of Cluster Rounded Indications if more than 1 group is present in a 6" length of weld: 1.0"

UW-52Cracks, Incomplete Penetration, and Incomplete Fusion:Slag Inclusions:Max Size of slag inclusions: 0.667"Max Cumulative length of acceptable in-line indications (other than rounded): 1.00" in a 6.00" length ofwelds and must be seperated by the length of 3L of acceptable weld metal.

Technique Sheet Info (Source Side of Object to Film and Source Distances)Reinforcement is found in the applicable penetrameter selection boxes above.

Source to Source Side of Object distance; DWE/DWV 9.750" Panoramic: 4.375"Source Side of Object to Film Distance: 1.00"

Page 371: NDT Code Book Made Easy

S

ASME SECTION VIII - PIPING ONLY

12" s/80 - 0.688" Wall

PENETRAMETER SELECTIONNote: Esn. Wire: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Hole 20 S/S Wire: 0.016 Esn Wire: B4 F/S Hole: 17 F/S Wire: 0.013 Esn Wire: B5Reinforced welds welded fromone side: S/S Hole: 25 S/S Wire: 0.020 Esn. Wire: B3

F/S Hole: 20 S/S Wire: 0.016 Esn. Wire: B4Reinforced welds welded fromtwo sides: S/S Hole: 30 S/S Wire: 0.025 Esn. Wire: B2

F/S Hole: 25 S/S Wire: 0.020 Esn. Wire: B3

Maximum allowable reinforcement if welded from one side: 0.188" Total of Wall + Reinforcement 0.876"Maximum allowable reinforcement if welded from two sides: 0.375" Total of Wall + Reinforcement 1.063"

PENETRAMETER SELECTION FOR API 620, 650, & 653Welds without reinforcement: Same as aboveWelds with reinforcement: S/S Hole: 25 S/S Wire: 0.020 Esn. Wire: B3

F/S Hole: 20 F/S Wire: 0.016 Esn. Wire: B4

Maximum allowable reinforcement: 0.094" Total of Wall + Reinforcement 0.782"

UW-51; API 620, 650, & 653Cracks, Incomplete Penetration, and Incomplete Fusion: None AllowedOther Elongated Indications (UW-51 only):Max Length of other elongated indications: 0.250"Max Cumulative length of aligned indications is 0.688" in a length of weld equal to 8.256" unlessseperated by the length of 6L Rounded Indications (UW-51 Only):Relevant Indications: 0.031"Max Size of Random Indications: 0.156" Max Size of Isolated Rounded Indications: 0.229"Max sum of diameters of Aligned Rounded Indications: 0.688" in a 8.256" length of weldMax group length of Aligned Rounded Indications: 0.250"Max group length of Cluster Rounded Indications if 1 group is present in a 6" length of weld: 1.0"Max group length of Cluster Rounded Indications if more than 1 group is present in a 6" length of weld: 1.0"

UW-52Cracks, Incomplete Penetration, and Incomplete Fusion:Slag Inclusions:Max Size of slag inclusions: 0.459"Max Cumulative length of acceptable in-line indications (other than rounded): 0.688" in a 4.128" length ofwelds and must be seperated by the length of 3L of acceptable weld metal.

Technique Sheet Info (Source Side of Object to Film and Source Distances)Reinforcement is found in the applicable penetrameter selection boxes above.

Source to Source Side of Object distance; DWE/DWV 12.062" Panoramic: 5.687"Source Side of Object to Film Distance: 0.688"

Page 372: NDT Code Book Made Easy

S

ASME SECTION VIII - PIPING ONLY

12" Extra Strong - 0.500" Wall

PENETRAMETER SELECTIONNote: Esn. Wire: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Hole 17 S/S Wire: 0.013 Esn Wire: B5 F/S Hole: 15 F/S Wire: 0.010 Esn Wire: A1 or B6Reinforced welds welded fromone side: S/S Hole: 20 S/S Wire: 0.016 Esn. Wire: B4

F/S Hole: 17 S/S Wire: 0.013 Esn. Wire: B5Reinforced welds welded fromtwo sides: S/S Hole: 25 S/S Wire: 0.020 Esn. Wire: B3

F/S Hole: 20 S/S Wire: 0.016 Esn. Wire: B4

Maximum allowable reinforcement if welded from one side: 0.156" Total of Wall + Reinforcement 0.656"Maximum allowable reinforcement if welded from two sides: 0.312" Total of Wall + Reinforcement 0.812"

PENETRAMETER SELECTION FOR API 620, 650, & 653Welds without reinforcement: Same as aboveWelds with reinforcement: S/S Hole: 20 S/S Wire: 0.016 Esn. Wire: B4

F/S Hole: 17 F/S Wire: 0.013 Esn. Wire: B5

Maximum allowable reinforcement: 0.0625" Total of Wall + Reinforcement 0.563"

UW-51; API 620, 650, & 653Cracks, Incomplete Penetration, and Incomplete Fusion: None AllowedOther Elongated Indications (UW-51 only):Max Length of other elongated indications: 0.250"Max Cumulative length of aligned indications is 0.500" in a length of weld equal to 6.00" unlessseperated by the length of 6L Rounded Indications (UW-51 Only):Relevant Indications: 0.031"Max Size of Random Indications: 0.125" Max Size of Isolated Rounded Indications: 0.167"Max sum of diameters of Aligned Rounded Indications: 0.500" in a 6.00" length of weldMax group length of Aligned Rounded Indications: 0.250"Max group length of Cluster Rounded Indications if 1 group is present in a 6" length of weld: 1.0"Max group length of Cluster Rounded Indications if more than 1 group is present in a 6" length of weld: 1.0"

UW-52Cracks, Incomplete Penetration, and Incomplete Fusion:Slag Inclusions:Max Size of slag inclusions: 0.334"Max Cumulative length of acceptable in-line indications (other than rounded): 0.500" in a 3.00" length ofwelds and must be seperated by the length of 3L of acceptable weld metal.

Technique Sheet Info (Source Side of Object to Film and Source Distances)Reinforcement is found in the applicable penetrameter selection boxes above.

Source to Source Side of Object distance; DWE/DWV 12.250" Panoramic: 5.875"Source Side of Object to Film Distance: 0.500"

Page 373: NDT Code Book Made Easy

S

ASME SECTION VIII - PIPING ONLY

12" s/120 - 1.00" Wall

PENETRAMETER SELECTIONNote: Esn. Wire: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Hole 25 S/S Wire: 0.020 Esn Wire: B3 F/S Hole: 20 F/S Wire: 0.016 Esn Wire: B4Reinforced welds welded fromone side: S/S Hole: 30 S/S Wire: 0.025 Esn. Wire: B2

F/S Hole: 25 S/S Wire: 0.020 Esn. Wire: B3Reinforced welds welded fromtwo sides: S/S Hole: 30 S/S Wire: 0.025 Esn. Wire: B2

F/S Hole: 25 S/S Wire: 0.020 Esn. Wire: B3

Maximum allowable reinforcement if welded from one side: 0.188" Total of Wall + Reinforcement 1.188"Maximum allowable reinforcement if welded from two sides: 0.375" Total of Wall + Reinforcement 1.375"

PENETRAMETER SELECTION FOR API 620, 650, & 653Welds without reinforcement: Same as aboveWelds with reinforcement: S/S Hole: 30 S/S Wire: 0.025 Esn. Wire: B2

F/S Hole: 25 F/S Wire: 0.020 Esn. Wire: B3

Maximum allowable reinforcement: 0.094" Total of Wall + Reinforcement 1.094"

UW-51; API 620, 650, & 653Cracks, Incomplete Penetration, and Incomplete Fusion: None AllowedOther Elongated Indications (UW-51 only):Max Length of other elongated indications: 0.333"Max Cumulative length of aligned indications is 1.00" in a length of weld equal to 12.00" unlessseperated by the length of 6L Rounded Indications (UW-51 Only):Relevant Indications: 0.031"Max Size of Random Indications: 0.156" Max Size of Isolated Rounded Indications: 0.250"Max sum of diameters of Aligned Rounded Indications: 1.00" in a 12.00" length of weldMax group length of Aligned Rounded Indications: 0.333"Max group length of Cluster Rounded Indications if 1 group is present in a 6" length of weld: 1.0"Max group length of Cluster Rounded Indications if more than 1 group is present in a 6" length of weld: 1.0"

UW-52Cracks, Incomplete Penetration, and Incomplete Fusion:Slag Inclusions:Max Size of slag inclusions: 0.667"Max Cumulative length of acceptable in-line indications (other than rounded): 1.00" in a 6.00" length ofwelds and must be seperated by the length of 3L of acceptable weld metal.

Technique Sheet Info (Source Side of Object to Film and Source Distances)Reinforcement is found in the applicable penetrameter selection boxes above.

Source to Source Side of Object distance; DWE/DWV 11.750" Panoramic: 5.375"Source Side of Object to Film Distance: 1.00"

Page 374: NDT Code Book Made Easy

S

ASME SECTION VIII - PIPING ONLY

12" s/160 - 1.312" Wall

PENETRAMETER SELECTIONNote: Esn. Wire: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Hole 30 S/S Wire: 0.025 Esn Wire: B2 F/S Hole: 25 F/S Wire: 0.020 Esn Wire: B3Reinforced welds welded fromone side: S/S Hole: 35 S/S Wire: 0.032 Esn. Wire: B1 or C6

F/S Hole: 30 S/S Wire: 0.025 Esn. Wire: B2Reinforced welds welded fromtwo sides: S/S Hole: 35 S/S Wire: 0.032 Esn. Wire: B1 or C6

F/S Hole: 30 S/S Wire: 0.025 Esn. Wire: B2

Maximum allowable reinforcement if welded from one side: 0.250" Total of Wall + Reinforcement 1.562"Maximum allowable reinforcement if welded from two sides: 0.500" Total of Wall + Reinforcement 1.812"

PENETRAMETER SELECTION FOR API 620, 650, & 653Welds without reinforcement: Same as aboveWelds with reinforcement: S/S Hole: 30 S/S Wire: 0.025 Esn. Wire: B2

F/S Hole: 25 F/S Wire: 0.020 Esn. Wire: B3

Maximum allowable reinforcement: 0.125" Total of Wall + Reinforcement 1.437"

UW-51; API 620, 650, & 653Cracks, Incomplete Penetration, and Incomplete Fusion: None AllowedOther Elongated Indications (UW-51 only):Max Length of other elongated indications: 0.437"Max Cumulative length of aligned indications is 1.312" in a length of weld equal to 15.744" unlessseperated by the length of 6L Rounded Indications (UW-51 Only):Relevant Indications: 0.031"Max Size of Random Indications: 0.156" Max Size of Isolated Rounded Indications: 0.250"Max sum of diameters of Aligned Rounded Indications: 1.312" in a 15.744" length of weldMax group length of Aligned Rounded Indications: 0.437"Max group length of Cluster Rounded Indications if 1 group is present in a 6" length of weld: 1.0"Max group length of Cluster Rounded Indications if more than 1 group is present in a 6" length of weld: 1.0"

UW-52Cracks, Incomplete Penetration, and Incomplete Fusion:Slag Inclusions:Max Size of slag inclusions: 0.750"Max Cumulative length of acceptable in-line indications (other than rounded): 1.312" in a 7.872" length ofwelds and must be seperated by the length of 3L of acceptable weld metal.

Technique Sheet Info (Source Side of Object to Film and Source Distances)Reinforcement is found in the applicable penetrameter selection boxes above.

Source to Source Side of Object distance; DWE/DWV 11.438" Panoramic: 5.063"Source Side of Object to Film Distance: 1.312"

Page 375: NDT Code Book Made Easy

S

ASME SECTION VIII - PIPING ONLY

12" XX Strong - 1.00" Wall

PENETRAMETER SELECTIONNote: Esn. Wire: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Hole 25 S/S Wire: 0.020 Esn Wire: B3 F/S Hole: 20 F/S Wire: 0.016 Esn Wire: B4Reinforced welds welded fromone side: S/S Hole: 30 S/S Wire: 0.025 Esn. Wire: B2

F/S Hole: 25 S/S Wire: 0.020 Esn. Wire: B3Reinforced welds welded fromtwo sides: S/S Hole: 30 S/S Wire: 0.025 Esn. Wire: B2

F/S Hole: 25 S/S Wire: 0.020 Esn. Wire: B3

Maximum allowable reinforcement if welded from one side: 0.188" Total of Wall + Reinforcement 1.188"Maximum allowable reinforcement if welded from two sides: 0.375" Total of Wall + Reinforcement 1.375"

PENETRAMETER SELECTION FOR API 620, 650, & 653Welds without reinforcement: Same as aboveWelds with reinforcement: S/S Hole: 30 S/S Wire: 0.025 Esn. Wire: B2

F/S Hole: 25 F/S Wire: 0.020 Esn. Wire: B3

Maximum allowable reinforcement: 0.094" Total of Wall + Reinforcement 1.094"

UW-51; API 620, 650, & 653Cracks, Incomplete Penetration, and Incomplete Fusion: None AllowedOther Elongated Indications (UW-51 only):Max Length of other elongated indications: 0.333"Max Cumulative length of aligned indications is 1.00" in a length of weld equal to 12.00" unlessseperated by the length of 6L Rounded Indications (UW-51 Only):Relevant Indications: 0.031"Max Size of Random Indications: 0.156" Max Size of Isolated Rounded Indications: 0.250"Max sum of diameters of Aligned Rounded Indications: 1.00" in a 12.00" length of weldMax group length of Aligned Rounded Indications: 0.333"Max group length of Cluster Rounded Indications if 1 group is present in a 6" length of weld: 1.0"Max group length of Cluster Rounded Indications if more than 1 group is present in a 6" length of weld: 1.0"

UW-52Cracks, Incomplete Penetration, and Incomplete Fusion:Slag Inclusions:Max Size of slag inclusions: 0.667"Max Cumulative length of acceptable in-line indications (other than rounded): 1.00" in a 6.00" length ofwelds and must be seperated by the length of 3L of acceptable weld metal.

Technique Sheet Info (Source Side of Object to Film and Source Distances)Reinforcement is found in the applicable penetrameter selection boxes above.

Source to Source Side of Object distance; DWE/DWV 11.750" Panoramic: 5.375"Source Side of Object to Film Distance: 1.00"

Page 376: NDT Code Book Made Easy

S

ASME SECTION VIII - PIPING ONLY

16" s/10 - 0.188" Wall

PENETRAMETER SELECTIONNote: Esn. Wire: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Hole 12 S/S Wire: 0.008 Esn Wire: A2 F/S Hole: 10 F/S Wire: 0.006 Esn Wire: A3Reinforced welds welded fromone side: S/S Hole: 15 S/S Wire: 0.010 Esn. Wire: A1 or B6

F/S Hole: 12 S/S Wire: 0.008 Esn. Wire: A2Reinforced welds welded fromtwo sides: S/S Hole: 17 S/S Wire: 0.013 Esn. Wire: B5

F/S Hole: 15 S/S Wire: 0.010 Esn. Wire: A1 or B6

Maximum allowable reinforcement if welded from one side: 0.125" Total of Wall + Reinforcement 0.313"Maximum allowable reinforcement if welded from two sides: 0.250" Total of Wall + Reinforcement 0.438"

PENETRAMETER SELECTION FOR API 620, 650, & 653Welds without reinforcement: Same as aboveWelds with reinforcement: S/S Hole: 15 S/S Wire: 0.010 Esn. Wire: A1 or B6

F/S Hole: 12 F/S Wire: 0.008 Esn. Wire: A2

Maximum allowable reinforcement: 0.0625" Total of Wall + Reinforcement 0.251"

UW-51; API 620, 650, & 653Cracks, Incomplete Penetration, and Incomplete Fusion: None AllowedOther Elongated Indications (UW-51 only):Max Length of other elongated indications: 0.250"Max Cumulative length of aligned indications is 0.188" in a length of weld equal to 2.256" unlessseperated by the length of 6L Rounded Indications (UW-51 Only):Relevant Indications: 0.016Max Size of Random Indications: 0.047" Max Size of Isolated Rounded Indications: 0.063"Max sum of diameters of Aligned Rounded Indications: 0.188" in a 2.256" length of weldMax group length of Aligned Rounded Indications: 0.250"Max group length of Cluster Rounded Indications if 1 group is present in a 6" length of weld: 0.376"Max group length of Cluster Rounded Indications if more than 1 group is present in a 6" length of weld: 1.0"

UW-52Cracks, Incomplete Penetration, and Incomplete Fusion:Slag Inclusions:Max Size of slag inclusions: 0.250"Max Cumulative length of acceptable in-line indications (other than rounded): 0.188" in a 1.128" length ofwelds and must be seperated by the length of 3L of acceptable weld metal.

Technique Sheet Info (Source Side of Object to Film and Source Distances)Reinforcement is found in the applicable penetrameter selection boxes above.

Source to Source Side of Object distance; DWE/DWV 15.812" Panoramic: 7.812"Source Side of Object to Film Distance: 0.188"

Page 377: NDT Code Book Made Easy

S

ASME SECTION VIII - PIPING ONLY

16" Standard - 0.375" Wall

PENETRAMETER SELECTIONNote: Esn. Wire: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Hole 15 S/S Wire: 0.010 Esn Wire: A1 or B6 F/S Hole: 12 F/S Wire: 0.008 Esn Wire: A2Reinforced welds welded fromone side: S/S Hole: 20 S/S Wire: 0.016 Esn. Wire: B4

F/S Hole: 17 S/S Wire: 0.013 Esn. Wire: B5Reinforced welds welded fromtwo sides: S/S Hole: 20 S/S Wire: 0.016 Esn. Wire: B4

F/S Hole: 17 S/S Wire: 0.013 Esn. Wire: B5

Maximum allowable reinforcement if welded from one side: 0.156" Total of Wall + Reinforcement 0.531"Maximum allowable reinforcement if welded from two sides: 0.312" Total of Wall + Reinforcement 0.687"

PENETRAMETER SELECTION FOR API 620, 650, & 653Welds without reinforcement: Same as aboveWelds with reinforcement: S/S Hole: 17 S/S Wire: 0.013 Esn. Wire: B5

F/S Hole: 15 F/S Wire: 0.010 Esn. Wire: A1 or B6

Maximum allowable reinforcement: 0.0625" Total of Wall + Reinforcement 0.438"

UW-51; API 620, 650, & 653Cracks, Incomplete Penetration, and Incomplete Fusion: None AllowedOther Elongated Indications (UW-51 only):Max Length of other elongated indications: 0.250"Max Cumulative length of aligned indications is 0.375" in a length of weld equal to 4.500" unlessseperated by the length of 6L Rounded Indications (UW-51 Only):Relevant Indications: 0.031"Max Size of Random Indications: 0.094" Max Size of Isolated Rounded Indications: 0.125"Max sum of diameters of Aligned Rounded Indications: 0.375" in a 4.500" length of weldMax group length of Aligned Rounded Indications: 0.250"Max group length of Cluster Rounded Indications if 1 group is present in a 6" length of weld: 0.750"Max group length of Cluster Rounded Indications if more than 1 group is present in a 6" length of weld: 1.0"

UW-52Cracks, Incomplete Penetration, and Incomplete Fusion:Slag Inclusions:Max Size of slag inclusions: 0.250"Max Cumulative length of acceptable in-line indications (other than rounded): 0.375" in a 2.250" length ofwelds and must be seperated by the length of 3L of acceptable weld metal.

Technique Sheet Info (Source Side of Object to Film and Source Distances)Reinforcement is found in the applicable penetrameter selection boxes above.

Source to Source Side of Object distance; DWE/DWV 15.625" Panoramic: 7.625"Source Side of Object to Film Distance: 0.375"

Page 378: NDT Code Book Made Easy

S

ASME SECTION VIII - PIPING ONLY

16" s/40 & Extra Strong - 0.500" Wall

PENETRAMETER SELECTIONNote: Esn. Wire: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Hole 17 S/S Wire: 0.013 Esn Wire: B5 F/S Hole: 15 F/S Wire: 0.010 Esn Wire: A1 or B6Reinforced welds welded fromone side: S/S Hole: 20 S/S Wire: 0.016 Esn. Wire: B4

F/S Hole: 17 S/S Wire: 0.013 Esn. Wire: B5Reinforced welds welded fromtwo sides: S/S Hole: 25 S/S Wire: 0.020 Esn. Wire: B3

F/S Hole: 20 S/S Wire: 0.016 Esn. Wire: B4

Maximum allowable reinforcement if welded from one side: 0.156" Total of Wall + Reinforcement 0.656"Maximum allowable reinforcement if welded from two sides: 0.312" Total of Wall + Reinforcement 0.812"

PENETRAMETER SELECTION FOR API 620, 650, & 653Welds without reinforcement: Same as aboveWelds with reinforcement: S/S Hole: 20 S/S Wire: 0.016 Esn. Wire: B4

F/S Hole: 17 F/S Wire: 0.013 Esn. Wire: B5

Maximum allowable reinforcement: 0.0625" Total of Wall + Reinforcement 0.563"

UW-51; API 620, 650, & 653Cracks, Incomplete Penetration, and Incomplete Fusion: None AllowedOther Elongated Indications (UW-51 only):Max Length of other elongated indications: 0.250"Max Cumulative length of aligned indications is 0.500" in a length of weld equal to 6.00" unlessseperated by the length of 6L Rounded Indications (UW-51 Only):Relevant Indications: 0.031"Max Size of Random Indications: 0.125" Max Size of Isolated Rounded Indications: 0.167"Max sum of diameters of Aligned Rounded Indications: 0.500" in a 6.00" length of weldMax group length of Aligned Rounded Indications: 0.250"Max group length of Cluster Rounded Indications if 1 group is present in a 6" length of weld: 1.00"Max group length of Cluster Rounded Indications if more than 1 group is present in a 6" length of weld: 1.0"

UW-52Cracks, Incomplete Penetration, and Incomplete Fusion:Slag Inclusions:Max Size of slag inclusions: 0.334"Max Cumulative length of acceptable in-line indications (other than rounded): 0.500" in a 3.00" length ofwelds and must be seperated by the length of 3L of acceptable weld metal.

Technique Sheet Info (Source Side of Object to Film and Source Distances)Reinforcement is found in the applicable penetrameter selection boxes above.

Source to Source Side of Object distance; DWE/DWV 15.500" Panoramic: 7.500"Source Side of Object to Film Distance: 0.500"

Page 379: NDT Code Book Made Easy

S

ASME SECTION VIII - PIPING ONLY

16" s/80 - 0.844" Wall

PENETRAMETER SELECTIONNote: Esn. Wire: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Hole 25 S/S Wire: 0.020 Esn Wire: B3 F/S Hole: 20 F/S Wire: 0.016 Esn Wire: B4Reinforced welds welded fromone side: S/S Hole: 30 S/S Wire: 0.025 Esn. Wire: B2

F/S Hole: 25 S/S Wire: 0.020 Esn. Wire: B3Reinforced welds welded fromtwo sides: S/S Hole: 30 S/S Wire: 0.025 Esn. Wire: B2

F/S Hole: 25 S/S Wire: 0.020 Esn. Wire: B3

Maximum allowable reinforcement if welded from one side: 0.188" Total of Wall + Reinforcement 1.032"Maximum allowable reinforcement if welded from two sides: 0.375" Total of Wall + Reinforcement 1.219"

PENETRAMETER SELECTION FOR API 620, 650, & 653Welds without reinforcement: Same as aboveWelds with reinforcement: S/S Hole: 25 S/S Wire: 0.020 Esn. Wire: B3

F/S Hole: 20 F/S Wire: 0.016 Esn. Wire: B4

Maximum allowable reinforcement: 0.094" Total of Wall + Reinforcement 0.938"

UW-51; API 620, 650, & 653Cracks, Incomplete Penetration, and Incomplete Fusion: None AllowedOther Elongated Indications (UW-51 only):Max Length of other elongated indications: 0.281"Max Cumulative length of aligned indications is 0.844" in a length of weld equal to 10.128" unlessseperated by the length of 6L Rounded Indications (UW-51 Only):Relevant Indications: 0.031"Max Size of Random Indications: 0.156" Max Size of Isolated Rounded Indications: 0.250"Max sum of diameters of Aligned Rounded Indications: 0.844" in a 10.128" length of weldMax group length of Aligned Rounded Indications: 0.281"Max group length of Cluster Rounded Indications if 1 group is present in a 6" length of weld: 1.00"Max group length of Cluster Rounded Indications if more than 1 group is present in a 6" length of weld: 1.0"

UW-52Cracks, Incomplete Penetration, and Incomplete Fusion:Slag Inclusions:Max Size of slag inclusions: 0.563"Max Cumulative length of acceptable in-line indications (other than rounded): 0.844" in a 5.064" length ofwelds and must be seperated by the length of 3L of acceptable weld metal.

Technique Sheet Info (Source Side of Object to Film and Source Distances)Reinforcement is found in the applicable penetrameter selection boxes above.

Source to Source Side of Object distance; DWE/DWV 15.156" Panoramic: 7.156"Source Side of Object to Film Distance: 0.844"

Page 380: NDT Code Book Made Easy

S

ASME SECTION VIII - PIPING ONLY

16" s/120 - 1.219" Wall

PENETRAMETER SELECTIONNote: Esn. Wire: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Hole 30 S/S Wire: 0.025 Esn Wire: B2 F/S Hole: 25 F/S Wire: 0.020 Esn Wire: B3Reinforced welds welded fromone side: S/S Hole: 30 S/S Wire: 0.025 Esn. Wire: B2

F/S Hole: 25 S/S Wire: 0.020 Esn. Wire: B3Reinforced welds welded fromtwo sides: S/S Hole: 35 S/S Wire: 0.032 Esn. Wire: B1 or C6

F/S Hole: 30 S/S Wire: 0.025 Esn. Wire: B2

Maximum allowable reinforcement if welded from one side: 0.250" Total of Wall + Reinforcement 1.469"Maximum allowable reinforcement if welded from two sides: 0.500" Total of Wall + Reinforcement 1.719"

PENETRAMETER SELECTION FOR API 620, 650, & 653Welds without reinforcement: Same as aboveWelds with reinforcement: S/S Hole: 30 S/S Wire: 0.025 Esn. Wire: B2

F/S Hole: 25 F/S Wire: 0.020 Esn. Wire: B3

Maximum allowable reinforcement: 0.125" Total of Wall + Reinforcement 1.344"

UW-51; API 620, 650, & 653Cracks, Incomplete Penetration, and Incomplete Fusion: None AllowedOther Elongated Indications (UW-51 only):Max Length of other elongated indications: 0.406"Max Cumulative length of aligned indications is 1.219" in a length of weld equal to 14.628" unlessseperated by the length of 6L Rounded Indications (UW-51 Only):Relevant Indications: 0.031"Max Size of Random Indications: 0.156" Max Size of Isolated Rounded Indications: 0.250"Max sum of diameters of Aligned Rounded Indications: 1.219" in a 14.628" length of weldMax group length of Aligned Rounded Indications: 0.406"Max group length of Cluster Rounded Indications if 1 group is present in a 6" length of weld: 1.00"Max group length of Cluster Rounded Indications if more than 1 group is present in a 6" length of weld: 1.0"

UW-52Cracks, Incomplete Penetration, and Incomplete Fusion:Slag Inclusions:Max Size of slag inclusions: 0.750"Max Cumulative length of acceptable in-line indications (other than rounded): 1.219" in a 7.314" length ofwelds and must be seperated by the length of 3L of acceptable weld metal.

Technique Sheet Info (Source Side of Object to Film and Source Distances)Reinforcement is found in the applicable penetrameter selection boxes above.

Source to Source Side of Object distance; DWE/DWV 14.781" Panoramic: 6.781"Source Side of Object to Film Distance: 1.219"

Page 381: NDT Code Book Made Easy

S

ASME SECTION VIII - PIPING ONLY

16" s/160 - 1.594" Wall

PENETRAMETER SELECTIONNote: Esn. Wire: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Hole 35 S/S Wire: 0.032 Esn Wire: B1 or C6 F/S Hole: 30 F/S Wire: 0.025 Esn Wire: B2Reinforced welds welded fromone side: S/S Hole: 35 S/S Wire: 0.032 Esn. Wire: B1 or C6

F/S Hole: 30 S/S Wire: 0.025 Esn. Wire: B2Reinforced welds welded fromtwo sides: S/S Hole: 40 S/S Wire: 0.040 Esn. Wire: C5

F/S Hole: 35 S/S Wire: 0.032 Esn. Wire: B1 or C6

Maximum allowable reinforcement if welded from one side: 0.250" Total of Wall + Reinforcement 1.844"Maximum allowable reinforcement if welded from two sides: 0.500" Total of Wall + Reinforcement 2.094"

PENETRAMETER SELECTION FOR API 620, 650, & 653Welds without reinforcement: Same as aboveWelds with reinforcement: S/S Hole: 35 S/S Wire: 0.032 Esn. Wire: B1 or C6

F/S Hole: 30 F/S Wire: 0.025 Esn. Wire: B2

Maximum allowable reinforcement: 0.125" Total of Wall + Reinforcement 1.719"

UW-51; API 620, 650, & 653Cracks, Incomplete Penetration, and Incomplete Fusion: None AllowedOther Elongated Indications (UW-51 only):Max Length of other elongated indications: 0.531"Max Cumulative length of aligned indications is 1.594" in a length of weld equal to 19.128" unlessseperated by the length of 6L Rounded Indications (UW-51 Only):Relevant Indications: 0.031"Max Size of Random Indications: 0.156" Max Size of Isolated Rounded Indications: 0.250"Max sum of diameters of Aligned Rounded Indications: 1.594" in a 19.128" length of weldMax group length of Aligned Rounded Indications: 0.531"Max group length of Cluster Rounded Indications if 1 group is present in a 6" length of weld: 1.00"Max group length of Cluster Rounded Indications if more than 1 group is present in a 6" length of weld: 1.0"

UW-52Cracks, Incomplete Penetration, and Incomplete Fusion:Slag Inclusions:Max Size of slag inclusions: 0.750"Max Cumulative length of acceptable in-line indications (other than rounded): 1.594" in a 9.564" length ofwelds and must be seperated by the length of 3L of acceptable weld metal.

Technique Sheet Info (Source Side of Object to Film and Source Distances)Reinforcement is found in the applicable penetrameter selection boxes above.

Source to Source Side of Object distance; DWE/DWV 14.406" Panoramic: 6.406"Source Side of Object to Film Distance: 1.594"

Page 382: NDT Code Book Made Easy

S

ASME SECTION VIII - PIPING ONLY

20" s/10 - 0.218" Wall

PENETRAMETER SELECTIONNote: Esn. Wire: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Hole 12 S/S Wire: 0.008 Esn Wire: A2 F/S Hole: 10 F/S Wire: 0.006 Esn Wire: A3Reinforced welds welded fromone side: S/S Hole: 15 S/S Wire: 0.010 Esn. Wire: A1 or B6

F/S Hole: 12 S/S Wire: 0.008 Esn. Wire: A2Reinforced welds welded fromtwo sides: S/S Hole: 20 S/S Wire: 0.016 Esn. Wire: B4

F/S Hole: 17 S/S Wire: 0.013 Esn. Wire: B5

Maximum allowable reinforcement if welded from one side: 0.156" Total of Wall + Reinforcement 0.374"Maximum allowable reinforcement if welded from two sides: 0.312" Total of Wall + Reinforcement 0.530"

PENETRAMETER SELECTION FOR API 620, 650, & 653Welds without reinforcement: Same as aboveWelds with reinforcement: S/S Hole: 15 S/S Wire: 0.010 Esn. Wire: A1 or B6

F/S Hole: 12 F/S Wire: 0.008 Esn. Wire: A2

Maximum allowable reinforcement: 0.0625" Total of Wall + Reinforcement 0.281"

UW-51; API 620, 650, & 653Cracks, Incomplete Penetration, and Incomplete Fusion: None AllowedOther Elongated Indications (UW-51 only):Max Length of other elongated indications: 0.250"Max Cumulative length of aligned indications is 0.218" in a length of weld equal to 2.616" unlessseperated by the length of 6L Rounded Indications (UW-51 Only):Relevant Indications: 0.016Max Size of Random Indications: 0.055" Max Size of Isolated Rounded Indications: 0.073"Max sum of diameters of Aligned Rounded Indications: 0.218" in a 2.616" length of weldMax group length of Aligned Rounded Indications: 0.250"Max group length of Cluster Rounded Indications if 1 group is present in a 6" length of weld: 0.436"Max group length of Cluster Rounded Indications if more than 1 group is present in a 6" length of weld: 1.0"

UW-52Cracks, Incomplete Penetration, and Incomplete Fusion:Slag Inclusions:Max Size of slag inclusions: 0.250"Max Cumulative length of acceptable in-line indications (other than rounded): 0.218" in a 1.308" length ofwelds and must be seperated by the length of 3L of acceptable weld metal.

Technique Sheet Info (Source Side of Object to Film and Source Distances)Reinforcement is found in the applicable penetrameter selection boxes above.

Source to Source Side of Object distance; DWE/DWV 19.782" Panoramic: 9.782"Source Side of Object to Film Distance: 0.218"

Page 383: NDT Code Book Made Easy

S

ASME SECTION VIII - PIPING ONLY

20" Standard - 0.375" Wall

PENETRAMETER SELECTIONNote: Esn. Wire: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Hole 15 S/S Wire: 0.010 Esn Wire: A1 or B6 F/S Hole: 12 F/S Wire: 0.008 Esn Wire: A2Reinforced welds welded fromone side: S/S Hole: 20 S/S Wire: 0.016 Esn. Wire: B4

F/S Hole: 17 S/S Wire: 0.013 Esn. Wire: B5Reinforced welds welded fromtwo sides: S/S Hole: 20 S/S Wire: 0.016 Esn. Wire: B4

F/S Hole: 17 S/S Wire: 0.013 Esn. Wire: B5

Maximum allowable reinforcement if welded from one side: 0.156" Total of Wall + Reinforcement 0.531"Maximum allowable reinforcement if welded from two sides: 0.312" Total of Wall + Reinforcement 0.687"

PENETRAMETER SELECTION FOR API 620, 650, & 653Welds without reinforcement: Same as aboveWelds with reinforcement: S/S Hole: 17 S/S Wire: 0.013 Esn. Wire: B5

` F/S Hole: 15 F/S Wire: 0.010 Esn. Wire: A1 or B6

Maximum allowable reinforcement: 0.0625" Total of Wall + Reinforcement 0.438"

UW-51; API 620, 650, & 653Cracks, Incomplete Penetration, and Incomplete Fusion: None AllowedOther Elongated Indications (UW-51 only):Max Length of other elongated indications: 0.250"Max Cumulative length of aligned indications is 0.375" in a length of weld equal to 4.500" unlessseperated by the length of 6L Rounded Indications (UW-51 Only):Relevant Indications: 0.031Max Size of Random Indications: 0.094" Max Size of Isolated Rounded Indications: 0.125"Max sum of diameters of Aligned Rounded Indications: 0.375" in a 4.500" length of weldMax group length of Aligned Rounded Indications: 0.250"Max group length of Cluster Rounded Indications if 1 group is present in a 6" length of weld: 0.750"Max group length of Cluster Rounded Indications if more than 1 group is present in a 6" length of weld: 1.0"

UW-52Cracks, Incomplete Penetration, and Incomplete Fusion:Slag Inclusions:Max Size of slag inclusions: 0.250"Max Cumulative length of acceptable in-line indications (other than rounded): 0.375" in a 2.250" length ofwelds and must be seperated by the length of 3L of acceptable weld metal.

Technique Sheet Info (Source Side of Object to Film and Source Distances)Reinforcement is found in the applicable penetrameter selection boxes above.

Source to Source Side of Object distance; DWE/DWV 19.625" Panoramic: 9.625"Source Side of Object to Film Distance: 0.375"

Page 384: NDT Code Book Made Easy

S

ASME SECTION VIII - PIPING ONLY

20" s/40 - 0.594" Wall

PENETRAMETER SELECTIONNote: Esn. Wire: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Hole 20 S/S Wire: 0.016 Esn Wire: B4 F/S Hole: 17 F/S Wire: 0.013 Esn Wire: B5Reinforced welds welded fromone side: S/S Hole: 25 S/S Wire: 0.020 Esn. Wire: B3

F/S Hole: 20 S/S Wire: 0.016 Esn. Wire: B4Reinforced welds welded fromtwo sides: S/S Hole: 25 S/S Wire: 0.020 Esn. Wire: B3

F/S Hole: 20 S/S Wire: 0.016 Esn. Wire: B4

Maximum allowable reinforcement if welded from one side: 0.188" Total of Wall + Reinforcement 0.782"Maximum allowable reinforcement if welded from two sides: 0.375" Total of Wall + Reinforcement 0.969"

PENETRAMETER SELECTION FOR API 620, 650, & 653Welds without reinforcement: Same as aboveWelds with reinforcement: S/S Hole: 20 S/S Wire: 0.016 Esn. Wire: B4

` F/S Hole: 17 F/S Wire: 0.013 Esn. Wire: B5

Maximum allowable reinforcement: 0.094" Total of Wall + Reinforcement 0.688"

UW-51; API 620, 650, & 653Cracks, Incomplete Penetration, and Incomplete Fusion: None AllowedOther Elongated Indications (UW-51 only):Max Length of other elongated indications: 0.250"Max Cumulative length of aligned indications is 0.594" in a length of weld equal to 7.128" unlessseperated by the length of 6L Rounded Indications (UW-51 Only):Relevant Indications: 0.031Max Size of Random Indications: 0.149" Max Size of Isolated Rounded Indications: 0.198"Max sum of diameters of Aligned Rounded Indications: 0.594" in a 7.128" length of weldMax group length of Aligned Rounded Indications: 0.250"Max group length of Cluster Rounded Indications if 1 group is present in a 6" length of weld: 1.00"Max group length of Cluster Rounded Indications if more than 1 group is present in a 6" length of weld: 1.0"

UW-52Cracks, Incomplete Penetration, and Incomplete Fusion:Slag Inclusions:Max Size of slag inclusions: 0.396"Max Cumulative length of acceptable in-line indications (other than rounded): 0.594" in a 3.564" length ofwelds and must be seperated by the length of 3L of acceptable weld metal.

Technique Sheet Info (Source Side of Object to Film and Source Distances)Reinforcement is found in the applicable penetrameter selection boxes above.

Source to Source Side of Object distance; DWE/DWV 19.406" Panoramic: 9.406"Source Side of Object to Film Distance: 0.594"

Page 385: NDT Code Book Made Easy

S

ASME SECTION VIII - PIPING ONLY

20" Extra Strong - 0.500" Wall

PENETRAMETER SELECTIONNote: Esn. Wire: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Hole 17 S/S Wire: 0.013 Esn Wire: B5 F/S Hole: 15 F/S Wire: 0.010 Esn Wire: A1 or B6Reinforced welds welded fromone side: S/S Hole: 20 S/S Wire: 0.016 Esn. Wire: B4

F/S Hole: 17 S/S Wire: 0.013 Esn. Wire: B5Reinforced welds welded fromtwo sides: S/S Hole: 25 S/S Wire: 0.020 Esn. Wire: B3

F/S Hole: 20 S/S Wire: 0.016 Esn. Wire: B4

Maximum allowable reinforcement if welded from one side: 0.156" Total of Wall + Reinforcement 0.656"Maximum allowable reinforcement if welded from two sides: 0.312" Total of Wall + Reinforcement 0.812"

PENETRAMETER SELECTION FOR API 620, 650, & 653Welds without reinforcement: Same as aboveWelds with reinforcement: S/S Hole: 20 S/S Wire: 0.016 Esn. Wire: B4

F/S Hole: 17 F/S Wire: 0.013 Esn. Wire: B5

Maximum allowable reinforcement: 0.0625" Total of Wall + Reinforcement 0.563"

UW-51; API 620, 650, & 653Cracks, Incomplete Penetration, and Incomplete Fusion: None AllowedOther Elongated Indications (UW-51 only):Max Length of other elongated indications: 0.250"Max Cumulative length of aligned indications is 0.500" in a length of weld equal to 6.00" unlessseperated by the length of 6L Rounded Indications (UW-51 Only):Relevant Indications: 0.031Max Size of Random Indications: 0.125" Max Size of Isolated Rounded Indications: 0.167"Max sum of diameters of Aligned Rounded Indications: 0.500" in a 6.00" length of weldMax group length of Aligned Rounded Indications: 0.250"Max group length of Cluster Rounded Indications if 1 group is present in a 6" length of weld: 1.00"Max group length of Cluster Rounded Indications if more than 1 group is present in a 6" length of weld: 1.0"

UW-52Cracks, Incomplete Penetration, and Incomplete Fusion:Slag Inclusions:Max Size of slag inclusions: 0.334"Max Cumulative length of acceptable in-line indications (other than rounded): 0.500" in a 3.00" length ofwelds and must be seperated by the length of 3L of acceptable weld metal.

Technique Sheet Info (Source Side of Object to Film and Source Distances)Reinforcement is found in the applicable penetrameter selection boxes above.

Source to Source Side of Object distance; DWE/DWV 19.500" Panoramic: 9.500"Source Side of Object to Film Distance: 0.500"

Page 386: NDT Code Book Made Easy

S

ASME SECTION VIII - PIPING ONLY

20" s/80 - 1.031" Wall

PENETRAMETER SELECTIONNote: Esn. Wire: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Hole 30 S/S Wire: 0.025 Esn Wire: B2 F/S Hole: 25 F/S Wire: 0.020 Esn Wire: B3Reinforced welds welded fromone side: S/S Hole: 30 S/S Wire: 0.025 Esn. Wire: B2

F/S Hole: 25 S/S Wire: 0.020 Esn. Wire: B3Reinforced welds welded fromtwo sides: S/S Hole: 35 S/S Wire: 0.032 Esn. Wire: B1 or C6

F/S Hole: 30 S/S Wire: 0.025 Esn. Wire: B2

Maximum allowable reinforcement if welded from one side: 0.250" Total of Wall + Reinforcement 1.281"Maximum allowable reinforcement if welded from two sides: 0.500" Total of Wall + Reinforcement 1.531"

PENETRAMETER SELECTION FOR API 620, 650, & 653Welds without reinforcement: Same as aboveWelds with reinforcement: S/S Hole: 30 S/S Wire: 0.025 Esn. Wire: B2

F/S Hole: 25 F/S Wire: 0.020 Esn. Wire: B3

Maximum allowable reinforcement: 0.125" Total of Wall + Reinforcement 1.156"

UW-51; API 620, 650, & 653Cracks, Incomplete Penetration, and Incomplete Fusion: None AllowedOther Elongated Indications (UW-51 only):Max Length of other elongated indications: 0.344"Max Cumulative length of aligned indications is 1.031" in a length of weld equal to 12.372" unlessseperated by the length of 6L Rounded Indications (UW-51 Only):Relevant Indications: 0.031Max Size of Random Indications: 0.156" Max Size of Isolated Rounded Indications: 0.250"Max sum of diameters of Aligned Rounded Indications: 1.031" in a 12.372" length of weldMax group length of Aligned Rounded Indications: 0.344"Max group length of Cluster Rounded Indications if 1 group is present in a 6" length of weld: 1.00"Max group length of Cluster Rounded Indications if more than 1 group is present in a 6" length of weld: 1.0"

UW-52Cracks, Incomplete Penetration, and Incomplete Fusion:Slag Inclusions:Max Size of slag inclusions: 0.688"Max Cumulative length of acceptable in-line indications (other than rounded): 1.031" in a 6.186" length ofwelds and must be seperated by the length of 3L of acceptable weld metal.

Technique Sheet Info (Source Side of Object to Film and Source Distances)Reinforcement is found in the applicable penetrameter selection boxes above.

Source to Source Side of Object distance; DWE/DWV 18.969" Panoramic: 8.969"Source Side of Object to Film Distance: 1.031"

Page 387: NDT Code Book Made Easy

S

ASME SECTION VIII - PIPING ONLY

20" s/120 - 1.500" Wall

PENETRAMETER SELECTIONNote: Esn. Wire: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Hole 30 S/S Wire: 0.025 Esn Wire: B2 F/S Hole: 25 F/S Wire: 0.020 Esn Wire: B3Reinforced welds welded fromone side: S/S Hole: 35 S/S Wire: 0.032 Esn. Wire: B1 or C6

F/S Hole: 30 S/S Wire: 0.025 Esn. Wire: B2Reinforced welds welded fromtwo sides: S/S Hole: 35 S/S Wire: 0.032 Esn. Wire: B1 or C6

F/S Hole: 30 S/S Wire: 0.025 Esn. Wire: B2

Maximum allowable reinforcement if welded from one side: 0.250" Total of Wall + Reinforcement 1.750"Maximum allowable reinforcement if welded from two sides: 0.500" Total of Wall + Reinforcement 2.000"

PENETRAMETER SELECTION FOR API 620, 650, & 653Welds without reinforcement: Same as aboveWelds with reinforcement: S/S Hole: 35 S/S Wire: 0.032 Esn. Wire: B1 or C6

F/S Hole: 30 F/S Wire: 0.025 Esn. Wire: B2

Maximum allowable reinforcement: 0.125" Total of Wall + Reinforcement 1.625"

UW-51; API 620, 650, & 653Cracks, Incomplete Penetration, and Incomplete Fusion: None AllowedOther Elongated Indications (UW-51 only):Max Length of other elongated indications: 0.500"Max Cumulative length of aligned indications is 1.500" in a length of weld equal to 18.00" unlessseperated by the length of 6L Rounded Indications (UW-51 Only):Relevant Indications: 0.031Max Size of Random Indications: 0.156" Max Size of Isolated Rounded Indications: 0.250"Max sum of diameters of Aligned Rounded Indications: 1.500" in a 18.00" length of weldMax group length of Aligned Rounded Indications: 0.500"Max group length of Cluster Rounded Indications if 1 group is present in a 6" length of weld: 1.00"Max group length of Cluster Rounded Indications if more than 1 group is present in a 6" length of weld: 1.0"

UW-52Cracks, Incomplete Penetration, and Incomplete Fusion:Slag Inclusions:Max Size of slag inclusions: 0.750"Max Cumulative length of acceptable in-line indications (other than rounded): 1.500" in a 9.00" length ofwelds and must be seperated by the length of 3L of acceptable weld metal.

Technique Sheet Info (Source Side of Object to Film and Source Distances)Reinforcement is found in the applicable penetrameter selection boxes above.

Source to Source Side of Object distance; DWE/DWV 18.500" Panoramic: 8.500"Source Side of Object to Film Distance: 1.500"

Page 388: NDT Code Book Made Easy

S

ASME SECTION VIII - PIPING ONLY

20" s/160 - 1.969" Wall

PENETRAMETER SELECTIONNote: Esn. Wire: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Hole 35 S/S Wire: 0.032 Esn Wire: B1 or C6 F/S Hole: 30 F/S Wire: 0.025 Esn Wire: B2Reinforced welds welded fromone side: S/S Hole: 40 S/S Wire: 0.040 Esn. Wire: C5

F/S Hole: 35 S/S Wire: 0.032 Esn. Wire: B1 or C6Reinforced welds welded fromtwo sides: S/S Hole: 40 S/S Wire: 0.040 Esn. Wire: C5

F/S Hole: 35 S/S Wire: 0.032 Esn. Wire: B1 or C6

Maximum allowable reinforcement if welded from one side: 0.250" Total of Wall + Reinforcement 2.129"Maximum allowable reinforcement if welded from two sides: 0.500" Total of Wall + Reinforcement 2.469"

PENETRAMETER SELECTION FOR API 620, 650, & 653Welds without reinforcement: Same as aboveWelds with reinforcement: S/S Hole: 40 S/S Wire: 0.040 Esn. Wire: C5

F/S Hole: 35 F/S Wire: 0.032 Esn. Wire: B1 or C6

Maximum allowable reinforcement: 0.125" Total of Wall + Reinforcement 2.094"

UW-51; API 620, 650, & 653Cracks, Incomplete Penetration, and Incomplete Fusion: None AllowedOther Elongated Indications (UW-51 only):Max Length of other elongated indications: 0.656"Max Cumulative length of aligned indications is 1.969" in a length of weld equal to 23.628" unlessseperated by the length of 6L Rounded Indications (UW-51 Only):Relevant Indications: 0.031Max Size of Random Indications: 0.156" Max Size of Isolated Rounded Indications: 0.250"Max sum of diameters of Aligned Rounded Indications: 1.969" in a 23.628" length of weldMax group length of Aligned Rounded Indications: 0.656"Max group length of Cluster Rounded Indications if 1 group is present in a 6" length of weld: 1.00"Max group length of Cluster Rounded Indications if more than 1 group is present in a 6" length of weld: 1.0"

UW-52Cracks, Incomplete Penetration, and Incomplete Fusion:Slag Inclusions:Max Size of slag inclusions: 0.750"Max Cumulative length of acceptable in-line indications (other than rounded): 1.969" in a 11.814" length ofwelds and must be seperated by the length of 3L of acceptable weld metal.

Technique Sheet Info (Source Side of Object to Film and Source Distances)Reinforcement is found in the applicable penetrameter selection boxes above.

Source to Source Side of Object distance; DWE/DWV 18.031" Panoramic: 8.031"Source Side of Object to Film Distance: 1.969"

Page 389: NDT Code Book Made Easy

S

ASME SECTION VIII - PIPING ONLY

24" s/10 - 0.250" Wall

PENETRAMETER SELECTIONNote: Esn. Wire: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Hole 12 S/S Wire: 0.008 Esn Wire: A2 F/S Hole: 10 F/S Wire: 0.006 Esn Wire: A3Reinforced welds welded fromone side: S/S Hole: 17 S/S Wire: 0.013 Esn. Wire: B5

F/S Hole: 15 S/S Wire: 0.010 Esn. Wire: A1 or B6Reinforced welds welded fromtwo sides: S/S Hole: 20 S/S Wire: 0.016 Esn. Wire: B4

F/S Hole: 17 S/S Wire: 0.013 Esn. Wire: B5

Maximum allowable reinforcement if welded from one side: 0.156" Total of Wall + Reinforcement 0.406"Maximum allowable reinforcement if welded from two sides: 0.312" Total of Wall + Reinforcement 0.562"

PENETRAMETER SELECTION FOR API 620, 650, & 653Welds without reinforcement: Same as aboveWelds with reinforcement: S/S Hole: 15 S/S Wire: 0.010 Esn. Wire: A1 or B6

F/S Hole: 12 F/S Wire: 0.008 Esn. Wire: A2

Maximum allowable reinforcement: 0.0625" Total of Wall + Reinforcement 0.313"

UW-51; API 620, 650, & 653Cracks, Incomplete Penetration, and Incomplete Fusion: None AllowedOther Elongated Indications (UW-51 only):Max Length of other elongated indications: 0.250"Max Cumulative length of aligned indications is 0.250" in a length of weld equal to 3.00" unlessseperated by the length of 6L Rounded Indications (UW-51 Only):Relevant Indications: 0.016"Max Size of Random Indications: 0.063" Max Size of Isolated Rounded Indications: 0.083"Max sum of diameters of Aligned Rounded Indications: 0.250" in a 3.00" length of weldMax group length of Aligned Rounded Indications: 0.250"Max group length of Cluster Rounded Indications if 1 group is present in a 6" length of weld: 0.500"Max group length of Cluster Rounded Indications if more than 1 group is present in a 6" length of weld: 1.0"

UW-52Cracks, Incomplete Penetration, and Incomplete Fusion:Slag Inclusions:Max Size of slag inclusions: 0.250"Max Cumulative length of acceptable in-line indications (other than rounded): 0.250" in a 1.500" length ofwelds and must be seperated by the length of 3L of acceptable weld metal.

Technique Sheet Info (Source Side of Object to Film and Source Distances)Reinforcement is found in the applicable penetrameter selection boxes above.

Source to Source Side of Object distance; DWE/DWV 23.750" Panoramic: 11.750"Source Side of Object to Film Distance: 0.250"

Page 390: NDT Code Book Made Easy

S

ASME SECTION VIII - PIPING ONLY

24" Standard - 0.375" Wall

PENETRAMETER SELECTIONNote: Esn. Wire: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Hole 15 S/S Wire: 0.010 Esn Wire: A1 or B6 F/S Hole: 12 F/S Wire: 0.008 Esn Wire: A2Reinforced welds welded fromone side: S/S Hole: 20 S/S Wire: 0.016 Esn. Wire: B4

F/S Hole: 17 S/S Wire: 0.013 Esn. Wire: B5Reinforced welds welded fromtwo sides: S/S Hole: 20 S/S Wire: 0.016 Esn. Wire: B4

F/S Hole: 17 S/S Wire: 0.013 Esn. Wire: B5

Maximum allowable reinforcement if welded from one side: 0.156" Total of Wall + Reinforcement 0.531"Maximum allowable reinforcement if welded from two sides: 0.312" Total of Wall + Reinforcement 0.687"

PENETRAMETER SELECTION FOR API 620, 650, & 653Welds without reinforcement: Same as aboveWelds with reinforcement: S/S Hole: 17 S/S Wire: 0.013 Esn. Wire: B5

F/S Hole: 15 F/S Wire: 0.010 Esn. Wire: A1 or B6

Maximum allowable reinforcement: 0.0625" Total of Wall + Reinforcement 0.438"

UW-51; API 620, 650, & 653Cracks, Incomplete Penetration, and Incomplete Fusion: None AllowedOther Elongated Indications (UW-51 only):Max Length of other elongated indications: 0.250"Max Cumulative length of aligned indications is 0.375" in a length of weld equal to 4.500" unlessseperated by the length of 6L Rounded Indications (UW-51 Only):Relevant Indications: 0.031"Max Size of Random Indications: 0.094" Max Size of Isolated Rounded Indications: 0.125"Max sum of diameters of Aligned Rounded Indications: 0.375" in a 4.500" length of weldMax group length of Aligned Rounded Indications: 0.250"Max group length of Cluster Rounded Indications if 1 group is present in a 6" length of weld: 0.750"Max group length of Cluster Rounded Indications if more than 1 group is present in a 6" length of weld: 1.0"

UW-52Cracks, Incomplete Penetration, and Incomplete Fusion:Slag Inclusions:Max Size of slag inclusions: 0.250"Max Cumulative length of acceptable in-line indications (other than rounded): 0.375" in a 2.250" length ofwelds and must be seperated by the length of 3L of acceptable weld metal.

Technique Sheet Info (Source Side of Object to Film and Source Distances)Reinforcement is found in the applicable penetrameter selection boxes above.

Source to Source Side of Object distance; DWE/DWV 23.625" Panoramic: 11.625"Source Side of Object to Film Distance: 0.375"

Page 391: NDT Code Book Made Easy

S

ASME SECTION VIII - PIPING ONLY

24" s/40 - 0.688" Wall

PENETRAMETER SELECTIONNote: Esn. Wire: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Hole 20 S/S Wire: 0.016 Esn Wire: B4 F/S Hole: 17 F/S Wire: 0.013 Esn Wire: B5Reinforced welds welded fromone side: S/S Hole: 25 S/S Wire: 0.020 Esn. Wire: B3

F/S Hole: 20 S/S Wire: 0.016 Esn. Wire: B4Reinforced welds welded fromtwo sides: S/S Hole: 30 S/S Wire: 0.025 Esn. Wire: B2

F/S Hole: 25 S/S Wire: 0.020 Esn. Wire: B3

Maximum allowable reinforcement if welded from one side: 0.188" Total of Wall + Reinforcement 0.876"Maximum allowable reinforcement if welded from two sides: 0.375" Total of Wall + Reinforcement 1.063"

PENETRAMETER SELECTION FOR API 620, 650, & 653Welds without reinforcement: Same as aboveWelds with reinforcement: S/S Hole: 25 S/S Wire: 0.020 Esn. Wire: B3

F/S Hole: 20 F/S Wire: 0.016 Esn. Wire: B4

Maximum allowable reinforcement: 0.094" Total of Wall + Reinforcement 0.782"

UW-51; API 620, 650, & 653Cracks, Incomplete Penetration, and Incomplete Fusion: None AllowedOther Elongated Indications (UW-51 only):Max Length of other elongated indications: 0.250"Max Cumulative length of aligned indications is 0.688" in a length of weld equal to 8.256" unlessseperated by the length of 6L Rounded Indications (UW-51 Only):Relevant Indications: 0.031"Max Size of Random Indications: 0.156" Max Size of Isolated Rounded Indications: 0.229"Max sum of diameters of Aligned Rounded Indications: 0.688" in a 8.256" length of weldMax group length of Aligned Rounded Indications: 0.250"Max group length of Cluster Rounded Indications if 1 group is present in a 6" length of weld: 1.00"Max group length of Cluster Rounded Indications if more than 1 group is present in a 6" length of weld: 1.0"

UW-52Cracks, Incomplete Penetration, and Incomplete Fusion:Slag Inclusions:Max Size of slag inclusions: 0.459"Max Cumulative length of acceptable in-line indications (other than rounded): 0.688" in a 4.128" length ofwelds and must be seperated by the length of 3L of acceptable weld metal.

Technique Sheet Info (Source Side of Object to Film and Source Distances)Reinforcement is found in the applicable penetrameter selection boxes above.

Source to Source Side of Object distance; DWE/DWV 23.312" Panoramic: 11.312"Source Side of Object to Film Distance: 0.688"

Page 392: NDT Code Book Made Easy

S

ASME SECTION VIII - PIPING ONLY

24" Extra Strong - 0.500" Wall

PENETRAMETER SELECTIONNote: Esn. Wire: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Hole 17 S/S Wire: 0.013 Esn Wire: B5 F/S Hole: 15 F/S Wire: 0.010 Esn Wire: A1 or B6Reinforced welds welded fromone side: S/S Hole: 20 S/S Wire: 0.016 Esn. Wire: B4

F/S Hole: 17 S/S Wire: 0.013 Esn. Wire: B5Reinforced welds welded fromtwo sides: S/S Hole: 25 S/S Wire: 0.020 Esn. Wire: B3

F/S Hole: 20 S/S Wire: 0.016 Esn. Wire: B4

Maximum allowable reinforcement if welded from one side: 0.156" Total of Wall + Reinforcement 0.656"Maximum allowable reinforcement if welded from two sides: 0.312" Total of Wall + Reinforcement 0.812"

PENETRAMETER SELECTION FOR API 620, 650, & 653Welds without reinforcement: Same as aboveWelds with reinforcement: S/S Hole: 20 S/S Wire: 0.016 Esn. Wire: B4

F/S Hole: 17 F/S Wire: 0.013 Esn. Wire: B5

Maximum allowable reinforcement: 0.0625" Total of Wall + Reinforcement 0.563"

UW-51; API 620, 650, & 653Cracks, Incomplete Penetration, and Incomplete Fusion: None AllowedOther Elongated Indications (UW-51 only):Max Length of other elongated indications: 0.250"Max Cumulative length of aligned indications is 0.500" in a length of weld equal to 6.00" unlessseperated by the length of 6L Rounded Indications (UW-51 Only):Relevant Indications: 0.031"Max Size of Random Indications: 0.125" Max Size of Isolated Rounded Indications: 0.167"Max sum of diameters of Aligned Rounded Indications: 0.500" in a 6.00" length of weldMax group length of Aligned Rounded Indications: 0.250"Max group length of Cluster Rounded Indications if 1 group is present in a 6" length of weld: 1.00"Max group length of Cluster Rounded Indications if more than 1 group is present in a 6" length of weld: 1.0"

UW-52Cracks, Incomplete Penetration, and Incomplete Fusion:Slag Inclusions:Max Size of slag inclusions: 0.334"Max Cumulative length of acceptable in-line indications (other than rounded): 0.500" in a 3.00" length ofwelds and must be seperated by the length of 3L of acceptable weld metal.

Technique Sheet Info (Source Side of Object to Film and Source Distances)Reinforcement is found in the applicable penetrameter selection boxes above.

Source to Source Side of Object distance; DWE/DWV 23.500" Panoramic: 11.500"Source Side of Object to Film Distance: 0.500"

Page 393: NDT Code Book Made Easy

S

ASME SECTION VIII - PIPING ONLY

24" s/80 - 1.219" Wall

PENETRAMETER SELECTIONNote: Esn. Wire: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Hole 30 S/S Wire: 0.025 Esn Wire: B2 F/S Hole: 25 F/S Wire: 0.020 Esn Wire: B3Reinforced welds welded fromone side: S/S Hole: 30 S/S Wire: 0.025 Esn. Wire: B2

F/S Hole: 25 S/S Wire: 0.020 Esn. Wire: B3Reinforced welds welded fromtwo sides: S/S Hole: 35 S/S Wire: 0.032 Esn. Wire: B1 or C6

F/S Hole: 30 S/S Wire: 0.025 Esn. Wire: B2

Maximum allowable reinforcement if welded from one side: 0.250" Total of Wall + Reinforcement 1.469"Maximum allowable reinforcement if welded from two sides: 0.500" Total of Wall + Reinforcement 1.719"

PENETRAMETER SELECTION FOR API 620, 650, & 653Welds without reinforcement: Same as aboveWelds with reinforcement: S/S Hole: 30 S/S Wire: 0.025 Esn. Wire: B2

F/S Hole: 25 F/S Wire: 0.020 Esn. Wire: B3

Maximum allowable reinforcement: 0.125" Total of Wall + Reinforcement 1.344"

UW-51; API 620, 650, & 653Cracks, Incomplete Penetration, and Incomplete Fusion: None AllowedOther Elongated Indications (UW-51 only):Max Length of other elongated indications: 0.406"Max Cumulative length of aligned indications is 1.219" in a length of weld equal to 14.628" unlessseperated by the length of 6L Rounded Indications (UW-51 Only):Relevant Indications: 0.031"Max Size of Random Indications: 0.156" Max Size of Isolated Rounded Indications: 0.250"Max sum of diameters of Aligned Rounded Indications: 1.219" in a 14.628" length of weldMax group length of Aligned Rounded Indications: 0.406"Max group length of Cluster Rounded Indications if 1 group is present in a 6" length of weld: 1.00"Max group length of Cluster Rounded Indications if more than 1 group is present in a 6" length of weld: 1.0"

UW-52Cracks, Incomplete Penetration, and Incomplete Fusion:Slag Inclusions:Max Size of slag inclusions: 0.750"Max Cumulative length of acceptable in-line indications (other than rounded): 1.219" in a 7.314" length ofwelds and must be seperated by the length of 3L of acceptable weld metal.

Technique Sheet Info (Source Side of Object to Film and Source Distances)Reinforcement is found in the applicable penetrameter selection boxes above.

Source to Source Side of Object distance; DWE/DWV 22.781" Panoramic: 10.781"Source Side of Object to Film Distance: 1.219"

Page 394: NDT Code Book Made Easy

S

ASME SECTION VIII - PIPING ONLY

24" s/160 - 2.344" Wall

PENETRAMETER SELECTIONNote: Esn. Wire: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Hole 40 S/S Wire: 0.040 Esn Wire: C5 F/S Hole: 35 F/S Wire: 0.032 Esn Wire: B1 or C6Reinforced welds welded fromone side: S/S Hole: 50 S/S Wire: 0.050 Esn. Wire: C4

F/S Hole: 40 S/S Wire: 0.040 Esn. Wire: C5Reinforced welds welded fromtwo sides: S/S Hole: 50 S/S Wire: 0.050 Esn. Wire: C4

F/S Hole: 40 S/S Wire: 0.040 Esn. Wire: C5

Maximum allowable reinforcement if welded from one side: 0.250" Total of Wall + Reinforcement 2.594"Maximum allowable reinforcement if welded from two sides: 0.500" Total of Wall + Reinforcement 2.844"

PENETRAMETER SELECTION FOR API 620, 650, & 653Welds without reinforcement: Same as aboveWelds with reinforcement: S/S Hole: 40 S/S Wire: 0.040 Esn. Wire: C5

F/S Hole: 35 F/S Wire: 0.032 Esn. Wire: B1 or C6

Maximum allowable reinforcement: 0.125" Total of Wall + Reinforcement 2.469"

UW-51; API 620, 650, & 653Cracks, Incomplete Penetration, and Incomplete Fusion: None AllowedOther Elongated Indications (UW-51 only):Max Length of other elongated indications: 0.750"Max Cumulative length of aligned indications is 2.344" in a length of weld equal to 28.128" unlessseperated by the length of 6L Rounded Indications (UW-51 Only):Relevant Indications: 0.063"Max Size of Random Indications: 0.156" Max Size of Isolated Rounded Indications: 0.375"Max sum of diameters of Aligned Rounded Indications: 2.344" in a 28.128" length of weldMax group length of Aligned Rounded Indications: 0.750"Max group length of Cluster Rounded Indications if 1 group is present in a 6" length of weld: 1.00"Max group length of Cluster Rounded Indications if more than 1 group is present in a 6" length of weld: 1.0"

UW-52Cracks, Incomplete Penetration, and Incomplete Fusion:Slag Inclusions:Max Size of slag inclusions: 0.750"Max Cumulative length of acceptable in-line indications (other than rounded): 2.344" in a 14.064" length ofwelds and must be seperated by the length of 3L of acceptable weld metal.

Technique Sheet Info (Source Side of Object to Film and Source Distances)Reinforcement is found in the applicable penetrameter selection boxes above.

Source to Source Side of Object distance; DWE/DWV 21.656" Panoramic: 9.656"Source Side of Object to Film Distance: 2.344"

Page 395: NDT Code Book Made Easy

S

ASME SECTION VIII - PIPING ONLY

36" s/10 - 0.312" Wall

PENETRAMETER SELECTIONNote: Esn. Wire: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Hole 15 S/S Wire: 0.010 Esn Wire: A1 or B6 F/S Hole: 12 F/S Wire: 0.008 Esn Wire: A2Reinforced welds welded fromone side: S/S Hole: 17 S/S Wire: 0.013 Esn. Wire: B5

F/S Hole: 15 S/S Wire: 0.010 Esn. Wire: A1 or B6Reinforced welds welded fromtwo sides: S/S Hole: 20 S/S Wire: 0.016 Esn. Wire: B4

F/S Hole: 17 S/S Wire: 0.013 Esn. Wire: B5

Maximum allowable reinforcement if welded from one side: 0.156" Total of Wall + Reinforcement 0.468"Maximum allowable reinforcement if welded from two sides: 0.312" Total of Wall + Reinforcement 0.624"

PENETRAMETER SELECTION FOR API 620, 650, & 653Welds without reinforcement: Same as aboveWelds with reinforcement: S/S Hole: 15 S/S Wire: 0.010 Esn. Wire: A1 or B6

F/S Hole: 12 F/S Wire: 0.008 Esn. Wire: A2

Maximum allowable reinforcement: 0.0625" Total of Wall + Reinforcement 0.375"

UW-51; API 620, 650, & 653Cracks, Incomplete Penetration, and Incomplete Fusion: None AllowedOther Elongated Indications (UW-51 only):Max Length of other elongated indications: 0.250"Max Cumulative length of aligned indications is 0.312" in a length of weld equal to 3.744" unlessseperated by the length of 6L Rounded Indications (UW-51 Only):Relevant Indications: 0.031"Max Size of Random Indications: 0.078" Max Size of Isolated Rounded Indications: 0.104"Max sum of diameters of Aligned Rounded Indications: 0.312" in a 3.744" length of weldMax group length of Aligned Rounded Indications: 0.250"Max group length of Cluster Rounded Indications if 1 group is present in a 6" length of weld: 0.624"Max group length of Cluster Rounded Indications if more than 1 group is present in a 6" length of weld: 1.0"

UW-52Cracks, Incomplete Penetration, and Incomplete Fusion:Slag Inclusions:Max Size of slag inclusions: 0.250"Max Cumulative length of acceptable in-line indications (other than rounded): 0.312" in a 1.872" length ofwelds and must be seperated by the length of 3L of acceptable weld metal.

Technique Sheet Info (Source Side of Object to Film and Source Distances)Reinforcement is found in the applicable penetrameter selection boxes above.

Source to Source Side of Object distance; DWE/DWV 35.688" Panoramic: 17.688"Source Side of Object to Film Distance: 0.312"

Page 396: NDT Code Book Made Easy

S

ASME SECTION VIII - PIPING ONLY

36" s/10 - 0.312" Wall

PENETRAMETER SELECTIONNote: Esn. Wire: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Hole 15 S/S Wire: 0.010 Esn Wire: A1 or B6 F/S Hole: 12 F/S Wire: 0.008 Esn Wire: A2Reinforced welds welded fromone side: S/S Hole: 17 S/S Wire: 0.013 Esn. Wire: B5

F/S Hole: 15 S/S Wire: 0.010 Esn. Wire: A1 or B6Reinforced welds welded fromtwo sides: S/S Hole: 20 S/S Wire: 0.016 Esn. Wire: B4

F/S Hole: 17 S/S Wire: 0.013 Esn. Wire: B5

Maximum allowable reinforcement if welded from one side: 0.156" Total of Wall + Reinforcement 0.468"Maximum allowable reinforcement if welded from two sides: 0.312" Total of Wall + Reinforcement 0.624"

PENETRAMETER SELECTION FOR API 620, 650, & 653Welds without reinforcement: Same as aboveWelds with reinforcement: S/S Hole: 15 S/S Wire: 0.010 Esn. Wire: A1 or B6

F/S Hole: 12 F/S Wire: 0.008 Esn. Wire: A2

Maximum allowable reinforcement: 0.0625" Total of Wall + Reinforcement 0.375"

UW-51; API 620, 650, & 653Cracks, Incomplete Penetration, and Incomplete Fusion: None AllowedOther Elongated Indications (UW-51 only):Max Length of other elongated indications: 0.250"Max Cumulative length of aligned indications is 0.312" in a length of weld equal to 3.744" unlessseperated by the length of 6L Rounded Indications (UW-51 Only):Relevant Indications: 0.031"Max Size of Random Indications: 0.078" Max Size of Isolated Rounded Indications: 0.104"Max sum of diameters of Aligned Rounded Indications: 0.312" in a 3.744" length of weldMax group length of Aligned Rounded Indications: 0.250"Max group length of Cluster Rounded Indications if 1 group is present in a 6" length of weld: 0.624"Max group length of Cluster Rounded Indications if more than 1 group is present in a 6" length of weld: 1.0"

UW-52Cracks, Incomplete Penetration, and Incomplete Fusion:Slag Inclusions:Max Size of slag inclusions: 0.250"Max Cumulative length of acceptable in-line indications (other than rounded): 0.312" in a 1.872" length ofwelds and must be seperated by the length of 3L of acceptable weld metal.

Technique Sheet Info (Source Side of Object to Film and Source Distances)Reinforcement is found in the applicable penetrameter selection boxes above.

Source to Source Side of Object distance; DWE/DWV 35.688" Panoramic: 17.688"Source Side of Object to Film Distance: 0.312"

Page 397: NDT Code Book Made Easy

S

ASME SECTION VIII - PIPING ONLY

36" Standard - 0.375" Wall

PENETRAMETER SELECTIONNote: Esn. Wire: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Hole 15 S/S Wire: 0.010 Esn Wire: A1 or B6 F/S Hole: 12 F/S Wire: 0.008 Esn Wire: A2Reinforced welds welded fromone side: S/S Hole: 20 S/S Wire: 0.016 Esn. Wire: B4

F/S Hole: 17 S/S Wire: 0.013 Esn. Wire: B5Reinforced welds welded fromtwo sides: S/S Hole: 20 S/S Wire: 0.016 Esn. Wire: B4

F/S Hole: 17 S/S Wire: 0.013 Esn. Wire: B5

Maximum allowable reinforcement if welded from one side: 0.156" Total of Wall + Reinforcement 0.531"Maximum allowable reinforcement if welded from two sides: 0.312" Total of Wall + Reinforcement 0.438"

PENETRAMETER SELECTION FOR API 620, 650, & 653Welds without reinforcement: Same as aboveWelds with reinforcement: S/S Hole: 17 S/S Wire: 0.013 Esn. Wire: B5

F/S Hole: 15 F/S Wire: 0.010 Esn. Wire: A1 or B6

Maximum allowable reinforcement: 0.0625" Total of Wall + Reinforcement 0.438"

UW-51; API 620, 650, & 653Cracks, Incomplete Penetration, and Incomplete Fusion: None AllowedOther Elongated Indications (UW-51 only):Max Length of other elongated indications: 0.250"Max Cumulative length of aligned indications is 0.375" in a length of weld equal to 4.500" unlessseperated by the length of 6L Rounded Indications (UW-51 Only):Relevant Indications: 0.031"Max Size of Random Indications: 0.094" Max Size of Isolated Rounded Indications: 0.125"Max sum of diameters of Aligned Rounded Indications: 0.375" in a 4.500" length of weldMax group length of Aligned Rounded Indications: 0.250"Max group length of Cluster Rounded Indications if 1 group is present in a 6" length of weld: 0.750"Max group length of Cluster Rounded Indications if more than 1 group is present in a 6" length of weld: 1.0"

UW-52Cracks, Incomplete Penetration, and Incomplete Fusion:Slag Inclusions:Max Size of slag inclusions: 0.250"Max Cumulative length of acceptable in-line indications (other than rounded): 0.375" in a 2.250" length ofwelds and must be seperated by the length of 3L of acceptable weld metal.

Technique Sheet Info (Source Side of Object to Film and Source Distances)Reinforcement is found in the applicable penetrameter selection boxes above.

Source to Source Side of Object distance; DWE/DWV 35.625" Panoramic: 17.625"Source Side of Object to Film Distance: 0.375"

Page 398: NDT Code Book Made Easy

S

ASME SECTION VIII - PIPING ONLY

36" Extra Strong - 0.500" Wall

PENETRAMETER SELECTIONNote: Esn. Wire: The letter refers to the ASTM set, the number is how many wires must be visible from largest to smallest.Welds without reinforcement: S/S Hole 17 S/S Wire: 0.013 Esn Wire: B5 F/S Hole: 15 F/S Wire: 0.010 Esn Wire: A1 or B6Reinforced welds welded fromone side: S/S Hole: 20 S/S Wire: 0.016 Esn. Wire: B4

F/S Hole: 17 S/S Wire: 0.013 Esn. Wire: B5Reinforced welds welded fromtwo sides: S/S Hole: 25 S/S Wire: 0.020 Esn. Wire: B3

F/S Hole: 20 S/S Wire: 0.016 Esn. Wire: B4

Maximum allowable reinforcement if welded from one side: 0.156" Total of Wall + Reinforcement 0.656"Maximum allowable reinforcement if welded from two sides: 0.312" Total of Wall + Reinforcement 0.812"

PENETRAMETER SELECTION FOR API 620, 650, & 653Welds without reinforcement: Same as aboveWelds with reinforcement: S/S Hole: 20 S/S Wire: 0.016 Esn. Wire: B4

F/S Hole: 17 F/S Wire: 0.013 Esn. Wire: B5

Maximum allowable reinforcement: 0.0625" Total of Wall + Reinforcement 0.563"

UW-51; API 620, 650, & 653Cracks, Incomplete Penetration, and Incomplete Fusion: None AllowedOther Elongated Indications (UW-51 only):Max Length of other elongated indications: 0.250"Max Cumulative length of aligned indications is 0.500" in a length of weld equal to 6.00" unlessseperated by the length of 6L Rounded Indications (UW-51 Only):Relevant Indications: 0.031"Max Size of Random Indications: 0.125" Max Size of Isolated Rounded Indications: 0.167"Max sum of diameters of Aligned Rounded Indications: 0.500" in a 6.00" length of weldMax group length of Aligned Rounded Indications: 0.250"Max group length of Cluster Rounded Indications if 1 group is present in a 6" length of weld: 1.00"Max group length of Cluster Rounded Indications if more than 1 group is present in a 6" length of weld: 1.0"

UW-52Cracks, Incomplete Penetration, and Incomplete Fusion:Slag Inclusions:Max Size of slag inclusions: 0.334"Max Cumulative length of acceptable in-line indications (other than rounded): 0.500" in a 3.00" length ofwelds and must be seperated by the length of 3L of acceptable weld metal.

Technique Sheet Info (Source Side of Object to Film and Source Distances)Reinforcement is found in the applicable penetrameter selection boxes above.

Source to Source Side of Object distance; DWE/DWV 35.500" Panoramic: 17.500"Source Side of Object to Film Distance: 0.500"