Neptune SafeAir Smoke evacuation The complete solution for evacuating surgical smoke from your operating theatre
Transcript
Page 1: Neptune SafeAir Smoke evacuation€¦ · The Neptune SafeAir Smoke Evacuation Pencils are also compatible with Stryker’s full offering of the Colorado MicroDissection needles. Part

Neptune SafeAirSmoke evacuation

The complete solution for evacuating surgical smoke from your operating theatre

The complete solution for evacuating surgical smoke from your operating theatre

Page 2: Neptune SafeAir Smoke evacuation€¦ · The Neptune SafeAir Smoke Evacuation Pencils are also compatible with Stryker’s full offering of the Colorado MicroDissection needles. Part

On-tip suction: surgical smoke is captured directly from the source

Push button: tactile feel push buttons for ease of operation

Rocker switch: rocker switch provides ergonomics activation

SafeAirSmoke Evacutation Pencils

EF

Captures smoke – and the potential hazards it carries – directly at the source reducing exposure

Ergonomic design aids transition from standard electrosurgical pencils

Pencil weighs just 21.7g to help preserve the surgeon's natural touch and feel

Compatible with the Neptune Waste Management System and the SafeAir Compact Smoke Evacuator

2-in-1 monopolar pencils perform smoke evacuation, electrosurgical cutting and coagulation

As part of the operating theatre team, you provide lifesaving and life changing care every day. And you do it in an environment with inherent risks such as surgical smoke. Surgical smoke is a genuine health concern spurring clinical, quality and safety groups around the world to take action – including us. With simple device solutions, education and fi nancing options we’re here to help you create a safer, smoke-free operating theatre.

Data shows that surgical smoke particles can travel 40 mph and multiply to more than 35 million particles/cubic metre in fi ve minutes1, 2. That’s why professional organisations advocate “on tip” smoke evacuation directly at the surgical site.3, 4, 5 To achieve this, we offer two SafeAir Smoke Evacuation Pencils; standard and telescoping enabling use on open surfaces and inside cavities.

Capture surgical smokeat the source

Page 3: Neptune SafeAir Smoke evacuation€¦ · The Neptune SafeAir Smoke Evacuation Pencils are also compatible with Stryker’s full offering of the Colorado MicroDissection needles. Part

Surface use: pencil shaft retracted with suction sleeve extended

Inside open cavities: pencil shaft extended with suction sleeve retracted

A full range of electrodes

SafeAir electrodes

Colorado MicroDisection Needles

A

B

C

DG

H

A Compatible with a range of SafeAir electrodes and Colorado Needles

B Tactile buttons provide security and control; available in push button or rocker switch

C Ergonomic design optimises grip and comfort

D Fully integrated suction/power cord is light and ultra fl exible for ease of motion and tangle-free cord management

E Electrode and suction sleeve telescope simultaneously reducing the need to change electrode

F Adjustable suction sleeve encircles electrode for smoke capture at any angle

G Pencil shaft telescopes up to 120mm, for a smoke inlet reach of 127mm

H Locking ring secures telescopic shaft at desired length

• Styles to suit specifi c needs (blade, ball, loop and conization)

• Coated, uncoated and insulated options

• A variety of diameters/widths (3-20mm), depths (8-20mm) and lengths (60-165mm)

• Versatility; 40+ confi gurations for microdissection

• Ultra sharp 5µ tungsten alloy tip

Page 4: Neptune SafeAir Smoke evacuation€¦ · The Neptune SafeAir Smoke Evacuation Pencils are also compatible with Stryker’s full offering of the Colorado MicroDissection needles. Part

The choice is yours:scalable solutions

Neptune 3Waste Management System

Safety and effi ciency• Compatible with SafeAir Smoke

Evacuation Pencils

• Integrated ULPA smoke evacuator fi lter captures potentially hazardous submicron particulates with 99.999% effi ciency6

• Auto mode automatically detects surgical smoke and adjusts fl ow

• Reduces hazardous exposure by suctioning surgical site fl uid, fl oor fl uid and surgical smoke

• Closed system locks away suctioned fl uids during cases, manifold changes, docking and transport; reducing exposure and spills

• Three layers of protection at manifold site via SealShut Technology; no open access points to internal canister

• Enables patient-to-patient use via simple manifold change

For the ultimate in streamlined functionality, look to the Neptune 3 Waste Management System. Not only does it provide smoke evacuation, but also quickly and effi ciently suctions and locks away surgical site and fl oor fl uids. The result is a simple way to perform multiple tasks while reducing exposure to potential hazards, from the fl oor you walk on to the air you breathe.

captures potentially hazardous submicron

Auto mode automatically detects surgical

Reduces hazardous exposure by suctioning surgical site fl uid, fl oor fl uid and surgical

Closed system locks away suctioned fl uids during cases, manifold changes, docking

Three layers of protection at manifold site via SealShut Technology; no open access

For the ultimate in streamlined functionality, look to the Neptune 3 Waste Management System. Not only does it provide smoke evacuation, but also quickly and effi ciently suctions and locks away surgical site and fl oor fl uids. The result is a simple way to perform multiple tasks while reducing exposure to potential hazards, from

Page 5: Neptune SafeAir Smoke evacuation€¦ · The Neptune SafeAir Smoke Evacuation Pencils are also compatible with Stryker’s full offering of the Colorado MicroDissection needles. Part

Simple to use; front panel coincides left-to-right with chronological setup steps

Minimal sound producing just 46dBa

Easily portable with minimal footprint (13 kg; 14cm H x 38cm W x 30cm D)

SafeAir Compact Smoke Evacuator

Simple to use; front panel coincides left-to-right with chronological setup steps

Minimal sound producing just 46dBa

Easily portable with minimal footprint (13 kg; 14cm H x 38cm W x 30cm D)

A B C D E F

The SafeAir Compact Smoke Evacuator provides suction for SafeAir Smoke Evacuation Pencils and is easily portable for use in the operating theatre or other procedure rooms. It contains many features that allow you to customise performance settings to suit the needs of various surgeons, patients and procedures.

A Auto activation via integrated sensor that detects pencil current

B ULPA fi ltration provides multiple benefi ts

• ULPA media – Captures potentially hazardous submicron particulates

• Carbon media – activated charcoal bed removes volatile organic compounds and odors from the air

C LED indicator tracks fi lter life; alerts when fi lter replacement is needed

D Proprietary vacuum design ensures instant “on-tip” suction at the desired level

• No ramp up time required to reach desired suction power

• Customisable via 10 speed settings

E Multiple activation modes: automatic, permanent and foot switch

F Customisable time delay; up to 10 seconds of smoke evacuation after pencil deactivation

Only ProCare technicians have the proprietary knowledge, tooling and parts to care for your surgical equipment, including Neptune and Safe Air smoke evacuators, in accordance with our manufacturing specifi cations. The ProCare Protect service plan provides annual preventive maintenance visits, plus unlimited repairs, with options like next day loaned equipment, to keep your Stryker equipment up and running.

ProCareServices

Page 6: Neptune SafeAir Smoke evacuation€¦ · The Neptune SafeAir Smoke Evacuation Pencils are also compatible with Stryker’s full offering of the Colorado MicroDissection needles. Part

Part number Description Length

SHK-EST-0065L Suction tip 65mm

SHK-EST-0125L Suction tip 125mm

SHK-EST-0165L Suction tip 165mm

Pencil – push button switch

Part number Description

SHK-VS-CL Integrated smoke evacuation pencil, coated 70mm blade, push button switch

SHK-VSL Integrated smoke evacuation pencil, non-coated 70mm blade, push button switch

Pencil – rocker switch

SHK-VS-C-RSL Integrated smoke evacuation pencil, coated 70mm blade, rocker switch

SHK-VS-RSL Integrated smoke evacuation pencil, non-coated 70mm blade, rocker switch

Telescopic pencil – push button switch

SHK-TSP-CL Integrated telescopic smoke evacuation pencil; coated 70mm blade; push button switch

SHK-TSPL Integrated telescopic smoke evacuation pencil; uncoated 70mm blade; push button switch

Suction sleeve

SHK-553-S-70 Needle electrode 70mm

SHK-553-S-70-MD MicroDissection Needle electrode 70mm

SHK-553-S-125 Needle electrode 125mm

Needle electrodes

Squared Blade

SHK-554-S-3-120 Ball electrode 3mm diameter 120mm

SHK-554-S-5-120 Ball electrode 5mm diameter 120mm

SHK-552-S-70-C-SQ Blade Electrode, 70mm, Coated, Square 70mm

Ball

SafeAir Smoke Evacuation Pencils & Electrodes

Pk/40

Pk/40

Pk/10

Pk/10

Pk/10

Pk/10

Pk/10

Page 7: Neptune SafeAir Smoke evacuation€¦ · The Neptune SafeAir Smoke Evacuation Pencils are also compatible with Stryker’s full offering of the Colorado MicroDissection needles. Part

Part number Description Length

SHK-552-S-70-C Blade electrode coated 70mm

SHK-552-S-70 Blade electrode 70mm

SHK-552-S-70-CI Blade electrode coated and insulated 70mm

SHK-552-S-70-CI2 Blade electrode coated and insulated, 2mm tip 70mm

SHK-552-S-125-C Blade electrode coated 125mm

SHK-552-S-125 Blade electrode 125mm

SHK-552-S-125-CI Blade electrode coated and insulated 125mm

SHK-552-S-165-C Blade electrode coated 165mm

SHK-552-S-165 Blade electrode 165mm

SHK-552-S-165-CI Blade electrode coated and insulated 165mm

Blade

The Neptune SafeAir Smoke Evacuation Pencils are also compatible with Stryker’s full offering of the Colorado MicroDissection needles.

Part number Description Width Depth Length

SHK-C1315-S-120 Conization electrode 13mm 15mm 120mm

SHK-C1320-S-120 Conization electrode 13mm 20mm 120mm

SHK-C1608-S-120 Conization electrode 16mm 8mm 120mm

SHK-C1618-S-120 Conization electrode 16mm 18mm 120mm

SHK-C2020-S-120 Conization electrode 20mm 20mm 120mm

SHK-T1010-S-120 Loop t-bar electrode 10mm 10mm 120mm

SHK-T1512-S-120 Loop t-bar electrode 15mm 12mm 120mm

SHK-T2015-S-120 Loop t-bar electrode 20mm 15mm 120mm

SHK-T2020-S-120 Loop t-bar electrode 20mm 20mm 120mm

SHK-T2015-S-60 Loop t-bar electrode 20mm 15mm 60mm

SHK-T2020-S-60 Loop t-bar electrode 20mm 20mm 60mm

SHK-U2020-S-120 Loop u-bar electrode 20mm 20mm 120mm

Loop and conization

Pk/10

Pk/10

Page 8: Neptune SafeAir Smoke evacuation€¦ · The Neptune SafeAir Smoke Evacuation Pencils are also compatible with Stryker’s full offering of the Colorado MicroDissection needles. Part

Compact smoke evacuator

SFR-COMPACT Compact smoke evacuator, stand alone 1

SFR-FIL-C ULPA fi lter, compact smoke evacuator 24

SFR-CON Smoke tubing for canister/fl uid trap 10

SFR-FSW Foot pedal, compact smoke evacuator 1

SFR-GC Grounding cable, compact smoke evacuator 1

Neptune Waste Management System

Neptune 3 Hardware

Part number Description

0703-002-000ENG Neptune 3 Rover 1

0702-015-000 Docking station (230V) 1

Neptune 3 Disposables

0702-020-000 4-Port manifold 20

0702-020-001 4-Port manifold with specimen collection 20

0702-034-000 Fluid suction HEPA fi ler with activated carbon 4

0700-001-026 Neptune docking station detergent 2

Neptune 3 Smoke Evacuation

0702-040-000 Smoke evacuator ULPA fi lter 4

0700-025-000 7/8” x 10’ Smoke evacuation tubing 10

0700-528-001 Tubing adapter 6mm x 22mm 1

0700-528-020 Tubing adapter 10mm x 22mm 1

Compact Smoke Evacuator

This document is intended solely for the use of healthcare professionalsA healthcare professional must always rely on his or her own professional clinical judgment when deciding whether to use a particular product when treating a particular patient. Stryker does not dispense medical advice and recommends that healhcare professionals be trained in the use of any particular product before using it in surgery. The information presented is intended to demonstrate the breadth of Stryker product offerings. A healthcare professional must always refer to the package insert, product label and/or instructions for use before using any Stryker product. Products may not be available in all markets because product availability is subject to the regulatory and/or medical practices in individual markets. Please contact your Stryker representative if you have questions about the availability of Stryker products in your area. ProCare service plans will be subject to the terms and conditions outlined in the service contract.

Stryker Corporation or its divisions or other corporate affi liated entities own, use or have applied for the following trademarks or service marks: SafeAir Neptune, ProCare, Stryker. All other trademarks are trademarks of their respective owners or holders. The medical devices depicted are CE marked in accordance with applicable EU Regulations and Directives. The material is not intended for distribution outside the EU and EFTA.

References:1. Recommended Practices for Electrosurgery (AORN; 2013;123-41) 2. 20. Brandon H.J. et al. “Characterization and removal of electrosurgical smoke.” Surg Serv Manage 3.3

(1997): 14-16.3. McCormick, P. “Bovie Smoke a Perilous Plume.” AANS Neurosurgeon 17.1 (2008): 10-12. Web. Accessed

March 3, 2016.4. Association of Perioperative Nurses (AORN). “Position Statement on Surgical Smoke and Bio-Aerosols, and

Recommended Practices for Electro-, Laser and MIS Surgery.” AORN Management of Surgical Smoke. Web Accessed March 3, 2016.

5. National Institute for Occupational Safety and Health (NIOSH). “Control of Smoke from Laser/Electric Surgical Procedures.” Hazard Control Alert HC11: (DHHS Publication #96-128). Web. Accessed March 3, 2016.

6. Stryker Instruments engineering data on fi le, September 2015, Kalamazoo, MI

Stryker European Operations B.V.Herikerbergweg 1101101 CM AmsterdamNetherlands P: + 31 20 219 2600

SMACC number:2018-19323 Rev None RK/2PM© 2018 Stryker | www.stryker.com