14
NETARHAT RESIDENTIAL SCHOOL DISCRIPTION OF CIVIL WORK FOR CONSTRUCTION OF GUARD ROOM AT NETARHAT RESIDENTIAL SCHOOL NETARHAT AT NETARHAT (PLEASE FILL THE RATE & SUBMIT WITH QUOTATION) ANNEXURE – 1 (Financial Bid) Sl. No. DESCRIPTION NOS. LENGTH WIDTH HEIGHT/DEPTH TOTAL QTY UNIT RATE AMOUNT 1/5.1.1 E/W in excavation in foundation trenches in ordinary soil (Vide classification of soil item A) and disposal of excavated earth as obtained to a distance up to 50M including all lifts leveling ramming the foundation trenches removing roots of trees shrubs all complete as per specification and direction of E/I. Column 4 3.00 3.00 3.50 126.00 cft Wall 2 8.83 3.00 3.50 3.57 cft 2 6.83 3.00 3.50 71.72 cft 201.28 cft 5.70 M 3 2/5.1.2 Extra for E/W in hard soil as per specification and direction of E/I (Vide classification of soil item B) Qty item no. 1 5.70 M 3
Transcript
Page 1: NETARHAT RESIDENTIAL SCHOOL DISCRIPTION OF CIVIL WORK … · measurement connected volume) Column 4 3.00 3.00 0.50 18.00 cft Wall 2 8.83 3.00 0.50 26.49 cft 2 6.83 3.00 0.50 20.49

NETARHAT RESIDENTIAL SCHOOL

DISCRIPTION OF CIVIL WORK FOR CONSTRUCTION OF GUARD ROOM AT NETARHAT RESIDENTIAL SCHOOL NETARHAT AT NETARHAT

(PLEASE FILL THE RATE & SUBMIT WITH QUOTATION)

ANNEXURE – 1 (Financial Bid)

Sl. No. DESCRIPTION NOS. LENGTH WIDTH HEIGHT/DEPTH

TOTAL

QTY UNIT RATE AMOUNT

1/5.1.1

E/W in excavation in

foundation trenches in

ordinary soil (Vide

classification of soil

item A) and disposal of

excavated earth as

obtained to a distance

up to 50M including all

lifts leveling ramming

the foundation

trenches removing

roots of trees shrubs

all complete as per

specification and

direction of E/I.

Column 4 3.00 3.00 3.50 126.00 cft

Wall 2 8.83 3.00 3.50 3.57 cft

2 6.83 3.00 3.50 71.72 cft

201.28 cft

5.70 M3

2/5.1.2

Extra for E/W in hard

soil as per specification

and direction of E/I

(Vide classification of

soil item B)

Qty item no. 1 5.70 M3

Page 2: NETARHAT RESIDENTIAL SCHOOL DISCRIPTION OF CIVIL WORK … · measurement connected volume) Column 4 3.00 3.00 0.50 18.00 cft Wall 2 8.83 3.00 0.50 26.49 cft 2 6.83 3.00 0.50 20.49

3/5.1.10

Providing coarse clean

sand in filling in

foundation trenches or

in plinth including

ramming and watering

in layers not exceeding

150mm thick with all

leads and lifts

including cost of all

materials labour

royalty and taxes all

complete as per

building specifiation

and direction of E/I

(Mode of

measurement

connected volume)

Column 4 3.00 3.00 0.50 18.00 cft

Wall 2 8.83 3.00 0.50 26.49 cft

2 6.83 3.00 0.50 20.49 cft

64.98 M3

4/5.6.3

Providing designation

75B one brick flat

soling joints filled with

local sand including

cost of watering taxes

royalty all complete as

per building

specification and

direction of E/I.

Column 4 3.00 3.00 36.00 sft

Wall 2 8.83 3.00 52.98 sft

2 6.63 3.00 39.78 sft

128.76 sft

3.65 M2

Page 3: NETARHAT RESIDENTIAL SCHOOL DISCRIPTION OF CIVIL WORK … · measurement connected volume) Column 4 3.00 3.00 0.50 18.00 cft Wall 2 8.83 3.00 0.50 26.49 cft 2 6.83 3.00 0.50 20.49

5/5.3.2.1.

Providing P.C.C.M-200

in nominal mix of

(1:1.5:3) in foundation

with approved quality

of stone chips 20mm

to 6mm size graded

and clean coarse sand

of F.M. 2.5 to 3

including screening.

Shuttering, mixing

cement concrete in

mixer and placing in

position vibrating

striking curing taxes

and royalty all comlete

as per building

specification and

direction E/I.

Column 4 3.00 3.00 0.25 9.00 cft

Wall 2 8.83 3.00 0.25 13.25 cft

2 6.83 3.00 0.25 10.25 cft

Room 1 8.00 6.00 0.25 32.49 cft

0.92 M3

6/5.3.14

Providing R.C.C.M. -

200 with nominal mix

of (1:1.5:3) in columns

with approved quality

or stone chips 20mm

to 6mm size graded

and clean coarse sand

of F.M. 2.5 to 3

including screening

shuttering mixing

cement concrete in

mixer and placing in

position vibrating

striking curing (but

excluding the cost of

reinforcement taxes

and royalty all

complete as per

building specification

and direction of E/I.

6 0.83 0.83 8.00 33.07 cft

0.94 M3

Page 4: NETARHAT RESIDENTIAL SCHOOL DISCRIPTION OF CIVIL WORK … · measurement connected volume) Column 4 3.00 3.00 0.50 18.00 cft Wall 2 8.83 3.00 0.50 26.49 cft 2 6.83 3.00 0.50 20.49

7/5.2.6

Providing desination

75B B/W in C.M. (1:6)

in foundation and

plinth with approved

qality of clean course

sand of FM 2 to 2.5

including providing 10

mm thick mortar joints

cost of screening

materials raking out

joints to 15mm depth

curing taxes and

royalty all complete as

per building

specification and

direction E/I.

1 31.32 1.25 1.50 58.73 cft

1 31.32 0.83 1.00 26.00 cft

84.72 cft

2.40 M3

8/5.3.6.1

Providing R.C.c.M. -

200 in bnd at plinth

level with approved

quality of stone chips

20mm to 6mm size

graded and clean

coarse sand of F.M. 2.5

to 3 including

screening shuttering

mixing cement

concrete in mixer and

placing in position

vibrating striking

curing (but excluding

the cost of

reinforcement taxes

and royalty all

complete as per

building specification

and direction E/I.

1 31.32 0.83 0.50 13.00 cft

0.37 M3

Page 5: NETARHAT RESIDENTIAL SCHOOL DISCRIPTION OF CIVIL WORK … · measurement connected volume) Column 4 3.00 3.00 0.50 18.00 cft Wall 2 8.83 3.00 0.50 26.49 cft 2 6.83 3.00 0.50 20.49

9/5.2.14

Providing designation

75B B/W in C.M. (1:6)

in superstructure with

approved quality of

clean coarse sand of

F.M. 2 to 2.5 including

providing 10mm thick

mortar joints cost of

screening materials

raking out joints to

15mm depth curing all

complete as per

building construction

and direction E/I.

1 31.32 0.83 9.00 233.96

1 7.00 4.00 0.83 23.24

2 4.00 4.00 0.83 26.56

4 4.00 2.00 1.00 32.00

1 31.32 0.83 0.50 13.00

4 0.83 0.83 9.00 24.80

114.36

3.24

M3

10/5.3.8.1

Providing R.C.C.M. -

200 with nominal mix

of (1:1.5:3) in intel

with approved quality

of stone chips 20mm

to 6mm size graded

and clean coarse sand

of F.M. 2.5 to 3

including screening

shuttering, mixing

cement concrete in

mixer and placing in

position vibrating

striking curing (but

excluding the cost of

reinforcement) taxes

and royalty all

complete as per

building specification

and direction E/I.

1 31.32 0.83 0.50 13.00 cft

Page 6: NETARHAT RESIDENTIAL SCHOOL DISCRIPTION OF CIVIL WORK … · measurement connected volume) Column 4 3.00 3.00 0.50 18.00 cft Wall 2 8.83 3.00 0.50 26.49 cft 2 6.83 3.00 0.50 20.49

0.37 M3

11/5.3.9.1

Providing R.C.C.M. -

200 with nominal mix

of (1:1.5:3) in roof slab

with approved quality

of stone chips 20 mm

to 6mm size graded

and clean coarse sand

of F.M. 2.5 to 3

including screening

shuttering mixing

cement concrete in

mixer and placing in

position vibrating

striking curing (but not

exceeding the cost of

reinforcement) taxes

and royalty all

complete as per

building specification

and direction E/I.

1 9.50 7.50 0.42 29.93 cft

1 8.00 6.00 0.25 12.00 cft

41.93 cft

0.85 M3

12/5.5.12

S/F/F M.S. grill made

of 20X6mm M.S. flat as

per approved design

and drawing properly

fabricated with joints

continuous filled

welded and finished

smooth carriage of grill

to work site hosting as

per building

specification and

direction of E/I.

2 4.00 4.00 32.00 sft

4 4.00 2.00 32.00 sft

64.00 sft

160.00 kg

Page 7: NETARHAT RESIDENTIAL SCHOOL DISCRIPTION OF CIVIL WORK … · measurement connected volume) Column 4 3.00 3.00 0.50 18.00 cft Wall 2 8.83 3.00 0.50 26.49 cft 2 6.83 3.00 0.50 20.49

13/21.1

Providing and fixing

aluminium work for

doors windows,

ventilators and

partition with

extruded built up

standard tubular

section/appropriate Z

section and other

sections of approved

make up forming to IS

733 and Is 1285 fixed

with rawl plugs and

screws or with fixing

clips or with expansion

hold fasteners

including necessary

filling up of gaps at

junctions at top

bottom and side with

required PVC

neoprene felt etc.

Aluminium sections

shall be smooth rust

free straight mirred

and jointed

machenically

whereever required.

21.1.1 For fixed position

Anodised aluminium

)anodized transparent

or dyed to required

shade according to IS

1868 Minimum anodic

coating of grade AC

15) kg 348.50

W 2 4.00 4.00 32.00 SFT

V 4 4.00 2.00 32.00 SFT

64.00 SFT

371.20 kg

Page 8: NETARHAT RESIDENTIAL SCHOOL DISCRIPTION OF CIVIL WORK … · measurement connected volume) Column 4 3.00 3.00 0.50 18.00 cft Wall 2 8.83 3.00 0.50 26.49 cft 2 6.83 3.00 0.50 20.49

14/21.3

Providing and fixing

glazing in aluminium

door, window,

ventilator shutters and

partitions etc. with

PVC/neoprene gasket

etc complete as per

the architectural

drawing and the

direction of E/I (Cost of

Aluminium snap

breading shall be paid

in basic item.

21.3.2 With flat glass panes of

5.50 mm thickness

Qty item no 13 64.00 sft

5.95 M2

5.5 Steel Work

Band at Plinth Level 13.00 2.0 kg/cft 26.00 ko

Column 33.07 2.5 kg/cft 82.67 ko

Band at plinth level 13.00 2 kg / cft 26.00 ko

Roof Slab 47.63 2.5 kg/cft 119.07 ko

253.74 ko

0.25 MT

15/5.5.4

Providing Tor steel

reinforcement 8mm

dia rods as per

approved design and

drawing excluding

carriage of MS bars to

work site cutting

bending and binding

with annealed wire

with cost of wire

removal of rust placing

the rods in position all

complete as per

building specification

and direction E/I. (TMT

coil Fe 500)

Page 9: NETARHAT RESIDENTIAL SCHOOL DISCRIPTION OF CIVIL WORK … · measurement connected volume) Column 4 3.00 3.00 0.50 18.00 cft Wall 2 8.83 3.00 0.50 26.49 cft 2 6.83 3.00 0.50 20.49

5.5.4+5.5.5

Providing Tor steel

reinforcement rods as

per approved design

and drawing excluding

carriage of M.S. bars to

work site cutting

bending and binding

with annealed wire

with cost of wire

removal of rust placing

the rods in position all

complete as per

building specification

and direction of E/I.

a) 10 mm (TMT coil Fe

500) + (b) 12mm TMT

COIL Fe 500 0.253 MT

16/5.7.3

Providing 12mm thick

cement plaster (1:6)

with clean coarse sand

of F.M. 1.5 including

screening curing with

all leads and lifts of

water scaffolding taxes

and royalty all

complete as per

building specification

and direction of E/I.

outer plaster 2 14.00 10.00 280.00 sft a

inner plaster 2 14.00 10.00 280.00 sft b

Total 546.00 sft

Deduction for opnin

D 1 7.00 4.00 28.00 sft

W 2 4.00 5.00 40.00 sft

V 2 4.00 4.00 32.00 sft

100.00 sft

446.00 M2

Page 10: NETARHAT RESIDENTIAL SCHOOL DISCRIPTION OF CIVIL WORK … · measurement connected volume) Column 4 3.00 3.00 0.50 18.00 cft Wall 2 8.83 3.00 0.50 26.49 cft 2 6.83 3.00 0.50 20.49

Providing 6mm thick

cement plaster (1:4) in

celling with clean

coarse sand of FM 1.5

including screening

curing with all leads

and lifts of water

scaffolding taxes and

royalty all complete as

per building

specification and

direction of E/I.

1 8.00 6.00 48.00 sft

4.46 M2

18/5.8.32

Providing two coats of

oil bound distemper of

approved shade and

make over a coat of

cement primer over

new surface including

preparing the

plastered surface by

rubbing smooth with

pumice stone of fine

sand paper applying

putty wherever

required scaffolding

washing of floors and

taxes all complete as

per building

specification and

direction of E/I.

Qty v item no 16 (b) 266.00 sft

less qty item no. 16 100.00 sft

166.00 sft

15.43 M2

19/5.8.45

Providing two coat of

synthetic enamel paint

of approved shade and

make over steel

surface including

cleanning the surface

thoroughly scaffolding

and taxes all complete

as per building

specification and

direction of E/I.

Page 11: NETARHAT RESIDENTIAL SCHOOL DISCRIPTION OF CIVIL WORK … · measurement connected volume) Column 4 3.00 3.00 0.50 18.00 cft Wall 2 8.83 3.00 0.50 26.49 cft 2 6.83 3.00 0.50 20.49

qty v iteno - 5 64.00 sft

5.95 M2

20/5.4.38

S/F/F 35mm thick solid

core type

non0decorative single

leaf flush shutters in

doors and windows

with block board core

blended with high

quality phenol

formaldehyde

synthetic resin both

side commercial

veneered of standard

make with oxidized

iron fitting such as

hinges sliding door

bolts tower bolts

bandles cleats sand

blocks and taxes all

complete as per

building specification

and direction E/I.

D 1 7.00 4.00 28.00 sft

2.60 M2

Providing two coats of

synthetic enamel paint

of approved shade and

make over old wooden

surface including

cleaning the surface

after removing dirt

including scales

smokes grease and

sand papering

including cost of

scaffolding and taxes

all complete as per

building specification

and direction of E/I.

qty v item no. 22 28.00 sft

2.60 M2

Page 12: NETARHAT RESIDENTIAL SCHOOL DISCRIPTION OF CIVIL WORK … · measurement connected volume) Column 4 3.00 3.00 0.50 18.00 cft Wall 2 8.83 3.00 0.50 26.49 cft 2 6.83 3.00 0.50 20.49

22/13.26

Providing and applying

plaster of paris putty

of 2mm thickness over

plastered surface to

prepare the surface

even and smooth

complete job as per

direction of E/I.

446.00 M2

23/13.46

Finishing walls with

Acrylic Smooth

exterior paint of

required shade.

13.46.1

New work (Two or

more coat applied @

1.67 ltr/10 sqm over

and including priming

coat of exterior primer

applied @ 2.20 kg/10

sqm)

280.00 sft

100.00 sft

180.00 sft

16.73 M2

24/5.8.45

Providing two coat of

synthetic enamel paint

of approved shade and

make over steel

surface including

cleaning the surface

thoroughly scaffoldind

and taxes all complete

as per building

specification and

direction of E/I.

qty v item no 12 64.00 sft

5.95 M2

Page 13: NETARHAT RESIDENTIAL SCHOOL DISCRIPTION OF CIVIL WORK … · measurement connected volume) Column 4 3.00 3.00 0.50 18.00 cft Wall 2 8.83 3.00 0.50 26.49 cft 2 6.83 3.00 0.50 20.49

25/11.41

Providing and laying

vitrified floor tiles in

different sizes

(thickness to be

specified by the

manufacturer) with

water absorption's less

than 0.08 % and

conforming to IS

15622 of approved

make in all colours and

shade laid on 20 mm

thick cement mortrar

1:4 (1 Cement 4

Coarse Sand) including

grouting the joints

with white cement and

matching pigment etc.

complete.

11.41.2 Size of Tile 600 X 600

mm

1 8.00 6.00 48.00 sft

4.46 M2

26/11.47

Providing and laying

vitrified tiles in

different sizes

(thickness to be

specified by the

manufacturer). With

water absorption less

than 0.08% and

conforming to IS

15622 of approved

brand & manufacturer

in all colours and

shade in skirting riser

of steps laid with

cement based high

polymer modified

quick set tile adhesive

(water based)

conforming to IS

15477, in average 6

mm thickness

including grouting of

joints )Payment for

grouting joints to be

made)

27/47.2 Size of Tile 600 X 600

mm

Page 14: NETARHAT RESIDENTIAL SCHOOL DISCRIPTION OF CIVIL WORK … · measurement connected volume) Column 4 3.00 3.00 0.50 18.00 cft Wall 2 8.83 3.00 0.50 26.49 cft 2 6.83 3.00 0.50 20.49

1 14.00 0.50 7.00 sft

0.65 M2

Carriage cost of

materials - all

complete as per

direction E/I.

SAND av. LEAD 30 KM 162.21 M2

Stone chips lead 37 km 3.14 M2

Bricks (1k + 29P) 113218.00 %

Date Vender Seal & Signature


Recommended