Case Study Page 1 of 13 Case TitleNetwork Management System (NMS) for RTN600 Equipment Kwan Chan Yip (K00714421) Optical Network Product Department Abstract Network Management system (NMS) is a system comprising software, firmware, and hardware used to manage a large and complex network. An NMS may receive alarms and alerts from multiple element management systems (EMSs), each of which manages one or more specific intelligent network elements (NEs). This study describe about transmission of the NM Information and the guide to connect NMS on OptiX RTN600 equipment. KeywordsMicrowave, NMS, Ethernet, WebLCT. Case Text: Situation One NMS trial had been done. This trial had involved 11 links. This case study is to provide the guide on how to configure and connect NMS. Description of problems or challenges OptiX RTN 600 equipment can connect the network with third-party microwave equipment, either comprised between the OptiX RTN 600 equipment only or from different manufacturers. The OptiX RTN 600 provides two auto-sensing 10M/100M Ethernet NM ports, which was connected through the internal HUB. For the connection between the equipment from different manufacturers, the NM information needs to be transparently transmitted among them to ensure the centralized management of all the microwave equipment on the network. In this case, a flexible access solution to the NM system can be used and help to improve the competitive capacity of the OptiX RTN 600 equipment. [1] When the network is comprised between the OptiX RTN 600 equipment only, the HW ECC protocol data is transmitted through the uniform DCC channel among the NEs. As we know, DCC cannot be transmitted when no microwave link or optical port
Transcript
Page 1: Network Management System (NMS) for RTN600 Equipment.pdf

Case Study

Page 1 of 13

Case Title: Network Management System (NMS) for RTN600 Equipment

Kwan Chan Yip (K00714421)

Optical Network Product Department

Abstract:Network Management system (NMS) is a system comprising software,

firmware, and hardware used to manage a large and complex network. An NMS may

receive alarms and alerts from multiple element management systems (EMSs), each of

which manages one or more specific intelligent network elements (NEs). This study

describe about transmission of the NM Information and the guide to connect NMS on

OptiX RTN600 equipment.

Keywords:Microwave, NMS, Ethernet, WebLCT.

Case Text:

Situation One NMS trial had been done. This trial had involved 11 links. This case study is

to provide the guide on how to configure and connect NMS.

Description of problems or challenges

OptiX RTN 600 equipment can connect the network with third-party microwave

equipment, either comprised between the OptiX RTN 600 equipment only or from

different manufacturers. The OptiX RTN 600 provides two auto-sensing 10M/100M

Ethernet NM ports, which was connected through the internal HUB.

For the connection between the equipment from different manufacturers, the NM

information needs to be transparently transmitted among them to ensure the centralized

management of all the microwave equipment on the network. In this case, a flexible

access solution to the NM system can be used and help to improve the competitive

capacity of the OptiX RTN 600 equipment. [1]

When the network is comprised between the OptiX RTN 600 equipment only, the

HW ECC protocol data is transmitted through the uniform DCC channel among the NEs.

As we know, DCC cannot be transmitted when no microwave link or optical port

Page 2: Network Management System (NMS) for RTN600 Equipment.pdf

Case Study

Page 2 of 13

connection exists between two sets of OptiX RTN 600 equipment. Therefore, the network

cables is using to connect the NE cascading ports between two sets of OptiX RTN 600 to

implement the ECC communication and transmit the NM information. [1]

This case study was concentrated on comprised between the OptiX RTN 600

equipment and describe about transmission of the NM Information and the guide to

connect NMS on OptiX RTN600 equipment.

This NMS trial was done:

1. To configure IP address at Huawei GNE radio link.

2. To test connectivity from NOC to NE through Kuantan GNE (Test visiblility router

from Kuala Lumpur up to Kuantan, and NE at GNE site up to last mile).

3. To initial / discover NE up to last mile.

4. To test NE NMS function.

Analysis, Strategies and Actions

We connect the internal HUB Ethernet for site A to site L via NM ports.

A B D C

H G F E

I J K L

Figure 1 NMS Lan cable connection

Page 3: Network Management System (NMS) for RTN600 Equipment.pdf

Case Study

Page 3 of 13

A BF CE

G

D

IH J K L

Figure 2 Visio NMS Connection

1. Connection between OptiX RTN and router.

We need to connect the NM port in site A, which was between OptiX RTN

620 and customer’s router which will connect to HQ Kuala Lumpur.

Figure 3 OptiX RTN 620

Figure 4 Router

Page 4: Network Management System (NMS) for RTN600 Equipment.pdf

Case Study

Page 4 of 13

Figure 5 Connection from OptiX RTN 600 to router via Lan cable

2. Connection between OptiX RTN and OptiX RTN.

We need to connect the NM port for other OptiX RTN equipment to

access the NMS. We connect Eth Hub to Eth to extend the Nm signal, where we

connect ETH HUB for upper equipment and connect to HUB for lower equipment.

Figure 6 SCC front panel

Page 5: Network Management System (NMS) for RTN600 Equipment.pdf

Case Study

Page 5 of 13

F

ETH HUB

ETH

igure 7 SCC front panel

There are two extension modes for the extended ECC which we can configure via

WebLCT:

1. Automatic mode

On an Ethernet, the NE with the largest IP address is automatically

considered as server and other NEs are automatically clients. The NEs

automatically establish TCP connections between the server and clients

and also establish corresponding MAC connections according to the TCP

connections. In the automatic mode, the server and clients need not be

manually specified.

2. Manual mode

In the manual mode, NEs establish TCP connections between the server

and clients according to the server, clients, IDs of connecting ports, which

are set manually and other information that is entered manually. They then

establish corresponding MAC connections according to the TCP

connections.

1. Select the NE from the Object Tree in the NE Explorer. Choose

Communication > ECC Management from the Function Tree.

Page 6: Network Management System (NMS) for RTN600 Equipment.pdf

Case Study

Page 6 of 13

F

2. Set the ECC extended mode. If ECC Extended Mode is set to

Auto mode, other parameters are invalid.

3. Set other parameters when the ECC extended mode is set to the

manual mode.

For the equipment which connects to router, we need set to Specified Mode. We will enter the parameters manually, while the other equipments from other sites in this

NMS connection were set to Auto Mode, where the largest IP address will be considered

as server.

igure 8 ECC Management

Page 7: Network Management System (NMS) for RTN600 Equipment.pdf

Case Study

Page 7 of 13

Next, we need to enter the IP address, subnet mask and gateway into the IDU that

we set to Specified Mode, which was connecting directly to router. In this case, the IDU

is in Wisma Celcom. An Internet Protocol (IP) address is a unique number that can

identify each host on a network. Gateway IP refers to a device on a network which sends

local network traffic to other networks, and subnet mask number helps to define the

relationship between the host and the rest of the network. In this case, the IP address,

subnet mask and gateway were given by the customer, which was record in their

database. Therefore, we just need to key in the related information and parameter into

the communication parameter setting.

HQ

Region office

igure 9 IP information & Parameter F

Page 8: Network Management System (NMS) for RTN600 Equipment.pdf

Case Study

Page 8 of 13

igure 10 NE Communication Parameter Setting F

Result

Now, we can connect the entire network via NMS. We now can access and login

from any of these site which was connect to NMS (Site A – Site L) and remote all others

site via remote and manage all site’s information.

F igure 11 NE Search list (Before Logged In)

Page 9: Network Management System (NMS) for RTN600 Equipment.pdf

Case Study

Page 9 of 13

Site Name

F igure 12 NE Search list (After Logged In)

F igure 13 NE ECC Link Management List

Page 10: Network Management System (NMS) for RTN600 Equipment.pdf

Case Study

Page 10 of 13

Suggestion or Review

For information, there was NO service will affected when we connect to NMS and

configure the IP address for router according to nature of work.

Besides, the NE cascading ports cannot be connected as a ring due to network

broadcast storm may occur, which will causes repeated reset of the SCC board [1]. As

both the Ethernet NM ports and the NE cascading ports on the SCC board of the OptiX

RTN 600 support the MDI and MDI-X auto-sensing function the network cable used for

the extended ECC can be the straight-through cable or the crossover cable. (The cable

type’s information will be provided below).

We also need to plan the IDs of NEs for all IDU in NMS. We need to follow few principles

when planning NE IDs [2]:

• The IDs of the NEs in a DCN should not be repeated.

• When the number of existing NEs does not exceed the range represented by the

basic ID, do not use the extended ID if possible.

Page 11: Network Management System (NMS) for RTN600 Equipment.pdf

Case Study

Page 11 of 13

Reference

[1] Song Xiaobin (2005), NM System Access Solutions for the OptiX RTN 600. Huawei Technologies Co., Ltd.

[2] Kwan Chan Yip (2008). Modified the NE ID on WebLCT. Huawei Technologies Co.,Ltd. [3] http://www.ertyu.org/steven_nikkel/ethernetcables.html

Date accessed: 20.10.2008 [4] http://en.wikipedia.org/wiki/Ethernet_crossover_cable Date accessed: 20.10.2008 [5] http://www.yourdictionary.com/nms Date accessed: 20.10.2008 [6] http://www.more.net/technical/netserv/tcpip/viewip.html

Date accessed: 26.10.2008

Appreciation 1. Mr. Liu WenTing

2. Mr. Kevin ChenKai

3. Mr. Silver Cheng ZhiYin

4. Mr. Tiou Chin Eng

5. Mr. Syabani Bin Ahmad

6. Celcom Microwave Project Team

Page 12: Network Management System (NMS) for RTN600 Equipment.pdf

Case Study

Page 12 of 13

LAN cable and pin assignment

Figure 14 SCC front panel

Source: NM System Access Solutions for the OptiX RTN 600

Figure 15 Modular plug pin positioning

igure 16 ETH/ETH-HUB interface pin assignment F

Page 13: Network Management System (NMS) for RTN600 Equipment.pdf

Case Study

Page 13 of 13

Table 1 ETH/ETH-HUB interface pin assignment

Interface Pin Signal

1 Transmitting data (+)

2 Transmitting data (-)

3 Receiving data (+)

6 Receiving data (-)

ETH/ETH-HUB

4, 5, 7, 8 Reserved The ETH/ETH-HUB interface supports MDI/MDI-X auto-sensing, which means it can also transmit data through pins 3 and 6, and receive data through pins 1 and 3.

Table 2 Straight-Through Wiring (both ends are the same)

RJ45 Pin # Wire Color (T568B)

Wire Diagram(T568B)

10Base-T Signal 100Base-TX Signal 1000Base-T Signal

1 White/Orange Transmit+ BI_DA+

2 Orange Transmit- BI_DA-

3 White/Green Receive+ BI_DB+

4 Blue Unused BI_DC+

5 White/Blue Unused BI_DC-

6 Green Receive- BI_DB-

7 White/Brown Unused BI_DD+

8 Brown Unused BI_DD-

Table 3 Cross Over Cable

RJ45 Pin # (END 1) Wire Color Diagram End

#1 RJ45 Pin #

(END 2) Wire Color Diagram End #2

1 White/Orange 1 White/Green

2 Orange 2 Green

3 White/Green 3 White/Orange

4 Blue 4 White/Brown

5 White/Blue 5 Brown

6 Green 6 Orange

7 White/Brown 7 Blue

8 Brown 8 White/Blue


Recommended