+ All Categories
Home > Documents > Network Management System User Manul

Network Management System User Manul

Date post: 05-Apr-2018
Category:
Upload: genesis-robert
View: 222 times
Download: 0 times
Share this document with a friend

of 37

Transcript
  • 8/2/2019 Network Management System User Manul

    1/37

    Content

    Chapter 1 Introduction to Network Management System (NMS) ..........................................................2

    1 Network Management System Structure ..............................................................................2

    2 Targets in Network Management system .............................................................................3

    3 Emanager NMS Platform .....................................................................................................3

    4 Network Management Agent Module ..................................................................................5

    5 Uplink Module .......................................................................................................................6

    6 16-slot NMS chassis ..............................................................................................................6

    Chapter 2 Installation ...............................................................................................................................8

    1 Install Emanager ...................................................................................................................8

    2 NMS hardware Sketch Map: .................................................................................................9

    3 Connections in NMS ............................................................................................................94 Management Agent Module OC-MB-C16M Description ................................................11

    5 Uplink Module OC-UL-C16M Description .......................................................................12

    6 OC-C16M Chassis Description .........................................................................................13

    7 Network Manageable Ethernet Media Converter ..............................................................14

    Chapter 3 Settings and Commands of Network Management Agent................................................... 16

    1 Set Network With Console ................................................................................................16

    2 Set Network Through Telnet ..............................................................................................18

    3 Base command of networks management agent ................................................................19

    Chapter 4 Emanager Network Management Platform ........................................................................24

    1 Toolbar ................................................................................................................................25

    2 Popup Menu .........................................................................................................................25

    3 Enter and Exit of the system ...............................................................................................27

    4 User Management ...............................................................................................................27

    5 Search networks equipment ................................................................................................28

    6 Inquire, Backup, Clear to alarm data or to landing log..................................................... 30

    7 The picture notes of control tree nodes ..............................................................................31

    8 The simulated map of equipment....................................................................................... 32

    9 Card Management ...............................................................................................................33

    Chapter 5 Web Management ...................................................................................................................361 User Login ...........................................................................................................................36

    2 Main Function .....................................................................................................................37

  • 8/2/2019 Network Management System User Manul

    2/37

    OptiCin Network Management System User Manual

    Chapter 1 Introduction to Network Management System (NMS)

    1 Network Management System Structure

    As the development of network communication, safety and reliability of networkhardware is becoming more and more important. The manageable Media ConverterModule can monitor the far and near Ethernet media converter through the controlcenter in hub house, defend and maintenance the network, and help networks operators

    better their service quality.

    Ethernet Media Converter Network Management System is specially designed tosuit the condition of Ethernet Media Converter, fiber link, temperature in the chassis,

    power supply module and fan of the chassis,etc., which are in the 16 slot far-distancemonitoring and management chassis.

    Based on the widely used Simple Network Management Protocol (SNMP),Network Management System (NMS) provides users a Windows2000 based solutionfar-distance management, which suits to establish a Wide Area Network (WAN) andfacilitates usersstable broad band IP network service.

    The Configuration of Network Management System is shown as below:

    Network Management System is composed of 3 sects

    1) Emanager software with graphical interfaces, running under Windows 2000 on PC

    2) Agent program, embedded in network management agent module OC-MB-C16M

    3) Ethernet Media Converter module, which is managed by the software.

    Two communication courses in networks management system

    1) Network management software Emanager and network management agent module

    OC-MB-C16M are all connected to the management net through Ethernet which isbased on TCP/IP, communicate with each other, transfer and manage messages

    with standard Simple Network Management Protocol (SNMP).

    2

  • 8/2/2019 Network Management System User Manul

    3/37

    OptiCin Network Management System User Manual

    2) OC-MB-C16M and OC-UL-C16M series Ethernet Media Converter are connectedto Chassis Monitor Module through Serial Communication Bus. The ChassisMonitor Module work with them with a PTM (Point To Mu1tipoint) mode and getthe working condition of Ethernet Media Converters supposed to be managed. A

    network management agent module OC-MB-C16M can monitor at least 15Ethernet media converters, and through Downlink Port, it can also manage otherEthernet media converters in other three chassis. So, if there is a Uplink ModuleOC-UL-C16M in each chassis, a OC-MB-C16M can manage at least 60 Ethernetmedia converters. The OC-UL-C16M is used to transmit serial data.

    2 Targets in Network Management system

    2.1 Main Equipments

    NMS and chassis work together to manage Ethernet Media Converters.

    Main equipment or module:

    1) Ethernet Media Converter module

    2) Multi Mode to Single Mode Converter module

    3) Power supply of chassis

    4) Chassis

    2.2 Main parameters

    1) Version informations of NMS module and chassis

    2) Voltages of power supply and electric fan

    3) Temperature of chassis

    4) Device informations of converter

    5) Physical informations of ports of converter

    6) Information Settings and working condition informations of converter

    3 Emanager NMS Platform

    3.1 Main functions

    Emanager can be anywhere in the TCP/IP management net and connect with

    network management agent modules through TCP/IP.

    Its structure and functions are shown as below.

    3

  • 8/2/2019 Network Management System User Manul

    4/37

    OptiCin Network Management System User Manual

    Emanager provide user a graphic user interface(GUI), through which user can do

    standard SNMP management and control operation, then transmit commands to agent.

    Meanwhile, through data storage adapted module, the software converts settings and

    condition data of the managed modules to a structure suitable to be saved, and save

    them into local files.

    3.2 Main Functions of Emanager

    Main functions of the software include Log on, Search, History, Request, Manage, and

    Help. Details are below.

    1) Log on: To log in or out

    2) Search: Setting of search function, auto-search, hand-search.

    3) Search is mainly to add a new node, which needs to be monitored, to the system by

    automatic or manual searching. User can import and export the node list, which

    includes all nodes found before.

    4) Warning record: setting of alarm stock, alarm inquire, export records, import records,

    alarm music.

    5) Request: To get the equipment conditions, loading log of user and status of broken-

    down records.

    6) Manage: To manage users (to add, delete and search a user, or edit the user

    properties.), to manage settings node name, node position, temperature warning

    threshold and the TreeList (to add and delete host node and sub-nodes, to add

    activated equipment, edit node name, delete the current equipment).

    7) Help: Operation specification, readme file about the software and the company.

    4

  • 8/2/2019 Network Management System User Manul

    5/37

    OptiCin Network Management System User Manual

    4 Network Management Agent Module

    4.1 Main functions

    Its structure and functions are shown as below.

    The agent program has the functions of SNMP Agent, and provides user a standardCommand Line Interface(CLI). With CLI, user can do managing work through localCONSOLE or far-distance TELNET, including setting SNMP Agent, operating on thetarget equipment, and setting system parameters, etc.

    SNMP Agent is the managed substantiality in the SNMP system. It converts theoperations in the management into operations on the target board. SNMP adapted layercan finish the protocol task of SNMP, including the splitting and sealing of SNMPdata,Traps sending, multi-protocols support, safe confirmation of user; SNMP MIB ismanaged information store, including standard MIB-II and user-defined managed

    information; SNMP MIB managed control connector offers the management to SNMPprotocol adapted layer and the visit to SNMP.

    The agent controlled substantiality makes SNMP Agent and managed control layervisit the object board. The serial target control channel offers the communication meanswith the managed module, for the agent controlled substantiality. The communicationframe in the said layer is user-defined.

    4.2 Main Functions and Features of Agent program

    The Agent program provides network management, through Telnet, Console andSNMP, user can easily get equipment running condition, and change equipment

    parameter settings on line .

    5

  • 8/2/2019 Network Management System User Manul

    6/37

    OptiCin Network Management System User Manual

    1) V1,V2C of SNMP are supported.

    2) User can backup data. After restarted, the system can restore all settings of before.

    3) User can monitor the sending and receiving data during serial communication, datasynchronization, and SNMP Agent running condition, etc.

    4) User can set time of all equipments with a target equipment, which ensures thenetwork synchronization.

    5) User can update on line.

    4.3 Agent module

    The kernel part of Agent module is integrated communication processor whichadopts Sumsung ARM7.Details are shown as below:

    1) ARM7 work frequency: 66MHz.

    2) 16MByte 8-bit FLASH

    3) 16MByte 8-bit SDRAM

    4) 1 10/100M RJ-45 connector

    5) 1 RS232 communication port with main parameters:

    Baud rate : 115200bps;

    Data Bit: 8;

    Stop Bit: 1;

    Parity Bit: No.

    5 Uplink Module

    Two main functions of uplink module: distributes passively the RS232 signal in the

    three serial communication channels which connect to the RJ45 socket on the main

    chassis to the RJ45 socket 1 and RJ45 socket 2 of the chassis who supports uplink

    module; converts the RS232 signal of serial communication channel in the chassis who

    supports uplink module into TTL signal, and connects the bottom board of uplink

    module with the bottom board of the chassis by connecting socket.

    6 16-slot NMS chassis

    The main features of 16-slot NMS chassis are detailed as below.

    1) 16 slots for modules, Agent control module or uplink module will be inserted into

    the first slot in the chassis.

    2) 15 manageable Ethernet Media Converters can be inserted; but those that are

    6

  • 8/2/2019 Network Management System User Manul

    7/37

    OptiCin Network Management System User Manual

    unmanageable, can not be managed by the system.

    3) Condition of temperature, fan and power supply in chassis can be measured.

    4) Double backup AC or DC power supply

    5) 3U height, suitable for 19 inches rack or frame.

    7

  • 8/2/2019 Network Management System User Manul

    8/37

    OptiCin Network Management System User Manual

    Chapter 2 Installation

    1 Install Emanager

    1.1 System SettingsTo install Emanager, system requirements are below:

    1) CPU:Pentium II 450 or further; Memory: 128Mbit; Harddisk space: more than

    20Mbit left.

    2) Windows 2000 Professional/Server with Service Pack 2

    3) Display resolution: 1024X768.

    4) A 10M or 10M/100M Ethernet card.

    1.2 Software Installation

    Install Windows 2000 Professional/Server and Service Pack 2.

    A. Confirm the operating system.B. Put the Emanager involved CD into CD-ROM, an installation interface will

    automatically appear. If not, please double click and run the Setup.exe file in the CD,

    run the software installation, or just run X:\Setup.exe in the command dialog. When a

    "Wise Installation System" dialog appear, click OK.

    C. Click "Next" button in the "Welcome" page.

    D. When the installation wizard ask to "Choose Destination Location", click "Browse"

    and choose a folder, or just use the default directory. Then click "Next".

    E. When the installation wizard ask to "Select Program Manager Group", enter the

    name of program group, or just use the default value, then click "Next".

    F. When the "Start Installation" page appears, click "Next".G. When the "Password" dialog pop up, enter and confirm your password which in

    included in the Sn.txt in the CD, then click "OK".

    H. Then the installation will begin, and when it is finished, a "Installation Complete"

    page will appear. Click "Finish" to complete the whole installation.

    1.3 Install SNMP Trap Service under Windows 2000

    To conform whether "SNMP Trap Service" is running under the operation

    system,select "Start"->"Setting"->"Control Panel"->"Managed Tool"->"Service". If

    there is no "SNMP Trap Service" service, just follow as below:

    First copy the SnmpTrap.exe in the CD and paste it under the X:\Winnt\System32directory. Then select "Start"->"Setting"->"Control Panel"->"Managed Tool"-

    >"Service"double click "SNMP Trap Service" in the service list, and click "Start" in

    the next pop-up dialog, then select Auto in the start-up sort option and click OK.

    1.4 Double click "Fiber Transceiver Network Management System" on the desktop and

    run the network management software.

    1.5 Enter username in the next Login dialog, where the default username is "admin" and

    default password, "123". Click "Login" and enter the Network Management System

    main interface.

    8

  • 8/2/2019 Network Management System User Manul

    9/37

    OptiCin Network Management System User Manual

    2 NMS hardware Sketch Map:

    Map 1

    3 Connections in NMS

    If the 10/100M RJ45 Ethernet port of the Network Management Agent Module is

    to be connected with Ethernet equipment, such as switch, a parallel mode twisted-pair

    should be used, while connected to NMS, the intersect mode twisted-pair. To make

    9

  • 8/2/2019 Network Management System User Manul

    10/37

    OptiCin Network Management System User Manual

    operation easier, lines between chassis and lines from OC-MB-C16M control port to

    NMS are all parallel mode twisted-pairs. And user can also use UTP or STP.

    Map 1 shows how to connect the network management system. The system is

    composed of at most 4 chassis. Each managed node should have a OC-MB-C16M,other chassis should have Uplink Module. The chassis with OC-MB-C16M is defined

    as No. 1 chassis, and others with OC-UL-C16M are defined as Chassis No.2, Chassis

    No.3, and Chassis No.4.

    Connection between chassis:

    1. Connect Downlink of OC-MB-C16M in Chassis No.1 to Uplink of OC-UL-C16M in Chassis No.2

    2. Connect Downlink1 of OC-UL-C16M in Chassis No.2 to Uplink of OC-UL-C16M in Chassis No.3

    3. Connect Downlink2 of OC-UL-C16M in Chassis No.2 to Uplink of OC-UL-C16M in Chassis No.4

    Setting Up Steps:

    1. Check and confirm the chassis is a manageable chassis. Model OC-C16M isrequired.

    2. Mark each chassis with No.1, No.2, No.3 and No.4, then fix them on the 19inches frame.

    3. Insert OC-MB-C16M into the first bus of Chassis No.1, and insert OC-UL-C16M into the first bus of Chassis No.2, Chassis No.3, and Chassis No.4.

    4. Insert the OC series network manageable Ethernet Media Converters into the4 chassis.

    5. Connect among the chassis.

    6. Connect the 10/100M Ethernet port of OC-MB-C16M in Chassis No.1 to thenet where the computer with EManager runs in.

    7. Connect the Console of OC-MB-C16M of Chassis No.1 to the terminal of

    configuration or the computer where the terminal emluator runs.

    8. Log in the embedded system of OC-MB-C16M through Console, and setparameters with system commands. Usually , user just changes the IP addressinto another IP address of the local net, and set the TRAP target IP address asthe IP address of the computer where EManager will run.

    9. Run Emanager software, and manage equipments through the main interface.

    10

  • 8/2/2019 Network Management System User Manul

    11/37

    OptiCin Network Management System User Manual

    4 Management Agent Module OC-MB-C16M Description

    There are 3 RJ45 ports in the front board of OC-MB-C16M. After inserted intochassis, the ports from the top to the bottom are detailed as below.

    4.1 The first port is for a 10/100 Ethernet connectormarked with 10/100M. Thisport is used to connect TCP/IP based network management net, so it can connectwith the NMS where EManager runs. Parallel lines can be used here.

    Pins of 10/100M Ethernet port are defined as below.

    PIN SIGNAL PIN SIGNAL

    1 Tx+ 5 NC2 Tx- 6 Rx-3 Rx+ 7 NC4 NC 8 NC

    4.2 The second port is for RS232 Consolemarked with Console. This is used toconnect the Console terminal or the computer where the Console terminal emluatorruns.

    Pins of the Console setting port are defined as below.

    PIN SIGNAL PIN SIGNAL

    1 NC 5 GND2 NC 6 RxD3 TxD 7 NC4 GND 8 NC

    4.3 The third port is for connection among chassis, marked with Downlink, signalsfrom 3 serial communication channels are included here to connect the other 3chassis.

    Pins are defined as below.

    PIN SIGNAL PIN SIGNAL

    1 RxD2(Chassis No.2) 5 GND2 TxD2(Chassis No.2) 6 TxD3(Chassis No.3)3 RxD3(Chassis No.3) 7 RxD4(Chassis No.4)4 GND 8 TxD4(Chassis No.4)

    11

  • 8/2/2019 Network Management System User Manul

    12/37

    OptiCin Network Management System User Manual

    4.4 The front panel of OC-MB-C16M has four indicate lights, details are below.

    IndicatorLight

    Definition Function

    PWR Power Indicator

    Link Link ConditionRx Receiving IndicatorTx Sending Indicator

    5 Uplink Module OC-UL-C16M Description

    There are 3 RJ45 ports in the front board of OC-UL-C16M. After inserted intochassis, the ports from the top to the bottom are detailed as below.

    1) The uplink RJ45port, marked with Uplink;

    2) The downlink RJ45port, marked with Downlink 1 ;

    3) The downlink RJ45port, marked with Downlink 2 ;

    If OC-UL-C16M is in the Chassis No.2, connect the RJ45 Uplink port to the RJ45Downlink port of the Chassis No.1 with eight cores parallel line.

    If OC-UL-C16M is in the Chassis No.3 or 4, connect the RJ45 Uplink port to theRJ45 Downlink1 or Downlink2 port of the Chassis No.2 with eight core parallel line.

    The Downlink1 of Chassis No.2 is used to connect the Uplink of Chassis No.3, and

    Downlink2 is used to connect the Uplink of Chassis No.4.

    And Downlink1 and Downlink2 of Chassis No.3 and 4, are not used here.

    There are three kinds of signal from the Uplink, they are all transferred to thenetwork management Agent module. Pins of the port are defined as below.

    PIN SIGNAL PIN SIGNAL

    1 RxD2(Chassis No.2) 5 GND2 TxD2(Chassis No.2) 6 TxD3(Chassis No.3)

    3 RxD3(Chassis No.3) 7 RxD4(Chassis No.4)4 GND 8 TxD4(Chassis No.4)

    12

  • 8/2/2019 Network Management System User Manul

    13/37

    OptiCin Network Management System User Manual

    Pins of the Downlink 1 are defined as below.

    PIN SIGNAL PIN SIGNAL

    1 RxD3(Chassis No.3) 5 GND

    2 TxD3(Chassis No.3) 6 NC3 NC 7 NC4 GND 8 NC

    Pins of the Downlink 2 are defined as below.

    PIN SIGNAL PIN SIGNAL

    1 RxD4(chassis4) 5 GND2 TxD4(chassis4) 6 NC3 NC 7 NC4 GND 8 NC

    There are two indicator lights PWR and Rx on the front panel of OC-UL-C16M,where PWR indicates the power status, and Rx indicates whether there are datatransferred or received.

    6 OC-C16MChassis Description

    The front panel of the 16-slot OC-C16M chassis are shown as below.

    As we can see from above, The OC-MB-C16M and OC-UL-C16M can be inserted in the first slot in

    the 16-slotOC-C16M chassis, and manage other 15 Ethernet Media Converters in other slots.

    Led status:

    Power Indicate Light

    LIGHT FUNCTION DESCRIPTION

    PS1 Power 1, +5V On: Normal; Off: Lack or faultFS1 Fan 1, +12V On: Normal; Off: Lack or faultPS2 Power 2, +5V On: Normal; Off: Lack or faultFS2 Fan 2, +12V On: Normal; Off: Lack or fault

    13

  • 8/2/2019 Network Management System User Manul

    14/37

    OptiCin Network Management System User Manual

    The definition of Pins (from the top down)

    Serial Status Description

    1 TxD Defined from secondary card, the serialcommunication signal outputs;

    Defined from agent card, the said serial signalis RxD

    2 RxD Defined from secondary card, the serialcommunication signal inputs;

    Defined from agent card, the said serial signal

    is TxD

    3 NC4 NC5 +5V Power 6 Ground7 GND8 A0 Address code positionA0, A0 is on low level9 A1 Address code positionA110 A2 Address code positionA211 A3 Address code positionA3

    The sketch map of module configuration

    7 Network Manageable Ethernet Media Converter

    14

  • 8/2/2019 Network Management System User Manul

    15/37

    OptiCin Network Management System User Manual

    Indicate Light of Ethernet Media Converter

    IndicateLight FUNCTION DESCRIPTION

    PWR Power On: Power OnFxLink Optical fiber link On: Connected

    Off: Disconnected

    FxRx Light signal receiving Flashing: Receiving Data

    Off: Not Receiving Data

    TxLink Electric link On: Connection Correct

    Off: No Connection

    TxRx Electric signal receiving Flashing: Receiving Data

    Off: Not Receiving Data

    15

  • 8/2/2019 Network Management System User Manul

    16/37

    OptiCin Network Management System User Manual

    Chapter 3 Settings and Commands of Network Management Agent

    Network Management Agent provides user Console interface and Telnet far-distance to login the system and manage network.

    1 Set Network With Console

    Connecting the serial communication port(s) (Com1 or Com2) of a computer andConsole of Network Management Agent through standard RS232 line(s), user can usethe computer terminal emulation program such as the super terminal program ofWindows 2000 or NetTerm etc.,enter the embed operating system and manageequipments and set the settings with commands provided by Network ManagementAgent.

    Port Settings:Baud rate: 115200bps;

    Data Bit: 8;

    Stop Bit: 1;

    Parity Bit: No

    Flow Control: No

    An example below shows how to set through Console with Hyper Terminal ofWindows operating system.

    1) Click Start and select Program -> Accesary -> super terminal, andclick super terminal to start the super terminal. Or just click Start, selectRun , enter Hypertrm and hit Enter.

    3) A Connection Description dialog will pop up at the beginning of the super

    terminal. Enter a connection name in Name, as ftnms, then select a icon andclick confirm, as shown below.

    4) Then a Connect To dialog will appear, if the console has been connected to

    Com1 of network managing computer Select COM1 or COM2 in the

    16

  • 8/2/2019 Network Management System User Manul

    17/37

    OptiCin Network Management System User Manual

    connection in use list box, and press Enter. As shown below.

    4) In the COM1 Properties dialog, set bite rate as 115200, data position as 8, oddor even efficacy code asno, stop position as 1, flow control asNo and finishit by click OK.As shown below.

    Now, user can set parameters of OC-MB-C16M through super terminal.

    5) System will display information as below.

    17

  • 8/2/2019 Network Management System User Manul

    18/37

    OptiCin Network Management System User Manual

    ---------------------------------------------------------------

    Fiber Transceiver BootLoader (Ver2.2 20060901)

    ---------------------------------------------------------------

    Now running code!Fiber Transceiver Network Management System

    Version 2.2

    Cannot Connect the time server!Initialization Finished, Exitingnms>? //The DOS prompt of common user mode isnms>, ? List out allexecutable commandsmenus: User_mode_commands :

    enable - Turn on admin_mode commandshelp - Description of the interactive help systemping - Send echo messages

    nms>enable //Turn on admin modePassword: //The default password of super user mode isadminafter logging in,

    change the password to your own.nms# //The DOS prompt of super user mode isnms#.

    After logging in as admin, user can set the network management system withcommands provided by managed terminal.

    And user can also save the settings above into a file by selecting Save in theFile menu.

    2 Set Network Through Telnet

    User can also set network by logging onto OC-MB-C16M through Intranet orInternet by telnet. If it is the first time for the OC-MB-C16M to be used and powered,and the IP address of Ethernet port has not been set properly yet, then the default IPaddress is 192.168.0.168.

    Detailed steps are shown as below.1 Intranet: Connect the computer with OC-MB-C16M through Ethernet.

    Internet: Connect the computer with far-distance OC-MB-C16M throughnetworks equipment such as router.

    2 Just select Start -> Run, enter TelnetIP address and press Enter.3 Then the Telnet dialog appears:

    Fiber Transceiver NMS,Ver 2.2(20060901)

    login: //Enter admin as username, and press Enter.password: //Enter admin as password, and turn on the common user mode.

    //Turn on the common user mode directly by console.

    nms>? //The DOS prompt of common user mode isnms>, ? List out all

    18

  • 8/2/2019 Network Management System User Manul

    19/37

    OptiCin Network Management System User Manual

    executable commandsnms>enable //Turn on admin modePassword: //The password of super user mode is adminafter logging in, change

    the password to your own.nms# //The DOS prompt of super user modenms#.

    After logging in as supperuser, user can set the network management system with

    commands provided by managed terminal.

    Note: If not necessary, do not change the IP address of Ethernet when setting

    through Telnet. Change it only when it is needed, and the parameter values are

    confirmed right. After the IP is changed, the Telnet will be disconnected and can

    be connected only after loading again. If user wants to delete the last letter,some

    conditions, press backspace key to show^Hin stead of delete, so please press

    Delete key to remove.

    3 Base command of networks management agent

    NMS Agent provides TELNET and CONSOLE interface, user can operate withcommand lines, and very easy get and monitor system settings, and if necessary usercan also set system parameters neatly according different requirement.

    Note:

    Required parameters when using the command[] Optional parameters , not required in the command| One of the parameters on the two sides of | can be chosen

    Time New Roman Font Part of command line, what user will enter withkeyboard

    italic Replaceable option,should be changed into parameter what userwants to set.

    No. 6 Black Output in the screen

    Skill:

    A All command of the system is in small letter, the system can distinguish the letterin small or in capital.

    B Help command: Enter ? to display help information of all commands; enter

    command ? or command parameter ? to display help information of the command.

    3.1 ethconfig

    Function: To set the Ethernet port parameter

    Format:

    ethconfig [stat]

    ethconfig [ip ]ethconfig [mask ]ethconfig [gateway ]

    Description:

    Ethconfig : To set IP address, subnet mask,gateway of the Ethernet.

    Option:ethconfig stat To display the current settings of the Ethernet

    19

  • 8/2/2019 Network Management System User Manul

    20/37

    OptiCin Network Management System User Manual

    module.ethconfig ipIP_ADDR To set the IP address of the Ethernet

    IP_ADDR format:A.B.C.Dethconfig maskMASK To set the sub-networks mask code subnet

    mask of EthernetMASKformat: A.B.C.D

    ethconfig gateway GATEWAY To set the networks bridge address of EthernetGATEWAYformat: A.B.C.D

    Notice: After parameters are changed, it can work only after the system is

    restarted.

    3.2 debug

    Function: Tool for Debugging

    Format:

    debug [stat]debug [snmp ]debug [com ]

    Description:

    This command provides user a on-line debugging method, through which user cantrace the running status of the current system and have the orientation of users fault.

    It is only when user manages system with command through the terminal of serialports that the debugging command information can be displayed; if through Telnet, it

    can not be invisible .Option:

    debug stat To display the current debugging statusdebug snmp on|off To open or close the debugging status of

    SNMP Agent,disable as defaultdebug com on|off To open or close the debugging status of serial

    communication port,disable as default

    3.3 password

    Function: To change users password

    Format:

    passwd [admin]

    Description:

    passwd is used to change password of user enable or admin.Option:

    passwd To change user enables password.passwd admin To change user admins password.

    If command line passwd XXX is used to change password of a user with

    username XXX, the system will give clew:Changing password forXXX

    Old password:

    Now enter the old password. If it is incorrect, system will clew Incorrectpassword.

    passwd: The password forXXXis unchanged., then finish the command.

    20

  • 8/2/2019 Network Management System User Manul

    21/37

    OptiCin Network Management System User Manual

    If the entered old password is correct, then system will clew:

    Enter the new password (minimum of 3, maximum of 10 characters)

    Please use a combination of upper and lower case letters and numbers.

    Enter new password:

    Now enter the new password, and press Enter. Password should be composed of3~10 letters, and not blank key. The below letters can be used as password:A~Z, a~z,0~9, ~!@#$%&_*+=etc.

    Then system will clew:

    Re-enter new password:

    Now enter the new password again. The input should be the same as the input ofabove, otherwise it will not be able to be changed.

    Remarks: If you have forgot the password, please contact the technique support of

    our company.

    3.4 reboot

    Function: To reboot the system

    Format:

    reboot

    Descriptio:

    This command is used to reboot the NMS Agent.After rebooted, new parameters will be set into the system. So this command can

    renew the system settings when systems are changed.

    Exmpale:

    nms#rebootNow will doing the system reboot,this will reboot the NMS agent,

    Are you sure?(Y for sure,other for no)?Now start rebooting...

    //Press any other key (including Enter) to cancel.You have cancelled the rebooting.

    //If you are using CONSOLE, you can see the rebooting informations. ( Not forTelent )

    3.5 system

    Function: To get or set the current system settings

    Format:system [stat]

    system [name ]system [contact ]system [location ]system [tmptmax ]system [tmptmin ]

    Description:

    This command is used to get or set system name, contact, location, system currenttime, etc. All these parameters are called Standard Settings in MIB of SNMP.

    Option:

    system stat To get the current information.

    21

  • 8/2/2019 Network Management System User Manul

    22/37

    OptiCin Network Management System User Manual

    system name SYSNAME To set systemname, less than 256 characters.system contact SYSCONTAC To set contact address, less than 256 characters.

    Usually set as contacts email.system location SYSLOCATION To set location less than 256 characters.system tmptmax Temperature Alarm Threshold To set temperature warning

    high threshold. When temperature inside

    reaches higher than the threshold, systemwill send temperature warning Trap

    system tmptmin Temperature Alarm Threshold To set temperature warninglow threshold. When temperature insidereaches lower than the threshold, systemwill send temperature warning Trap

    3.6 timesync

    Function: To set address of time synchronization server, which synchronizes time of

    the local machineFormat:

    timesync [addr [IP_ADDRESS|null]]timesync [update]

    Description:

    NMS control board has no CMOS clock like that in PC, in order to get the correctcurrent time, the system DayTime defined in RFC876 protocol to get the current time.

    When the system reboots, it will get the current time from DayTime time server, andrenew the time of the system.Option:

    timesync addr To get IP address of DayTime server.timesync addrIP_ADDRESS To set IP address of DayTime server. Usually the

    server is set on a stably running host computer.timesync addr null To cancel the address of DayTime. At this moment, time

    synchronization operation is not permitted.timesync update To get the current time from DayTime server, and renew the

    time of the system. If the DayTime server does not exist, or it isnot opened, system will give error massage.

    Notice: If user has set a DayTime server for the system, while system can not visit

    the IP address, or the IP address doesnt exist, during rebooting, system will

    need more time to wait for answer from the server, which make the rebooting

    process very long. At this moment, user can connect NMS Agent throughTelnet, and cancel the IP address, or reset the IP address of the DayTime

    server.

    3.7 trap

    Function: To get or set the trap settings

    Format:

    trap [stat]trap [rocommunity [ROCOMMUNITY]]trap [target [TARGET]]

    Description:

    22

  • 8/2/2019 Network Management System User Manul

    23/37

    OptiCin Network Management System User Manual

    This command is used to get or set parameters of TRAP, e.g. ROCOMMUNITY,TARGET. By default, ROCOMMUNITY is set null, PORT is set 162. IfROCOMMUNITY or TARGET is set null, TRAP will not be sent.Option:

    trap stat To get the current Trap settings

    trap rocommunity To get the current ROCOMMUNITY settings, default value ispublic.

    trap rocommunity ROCOMMUNITY To set rocommunity value.trap target To get the current TARGET, default value is null.trap target index TARGET To set the target IP address where Trap will be

    sent(index=1,2,3)

    If TARGET is not set, system will not send trap defined in NMS MIB. After changing

    the target address, user needs to reboot the system with reboot command.

    3.8 upgrade

    Function: To upgrade the system online.

    Format:

    upgrade ftpip

    Description:

    This command is used to upgrade the system. Before updating the system, put the

    mapping file Image.ram into the given FTP server directory, and run thiscommand. After user entering upgradeftpip, system will prompt:

    Now will doing the system upgrade,this will cover the origin program,do you sure?(Yfor sure,other for no)?

    Then system continues to prompt:Upgrade the system application will need several miniutes,please wait....

    After upgrade, user needs to reboot the system manually.

    Notice: When system is running this command, it should not be stopped, for

    example , to reboot the system. Otherwise, unexpected error may occur, and the

    system may not be able to start anymore. If this happens, please contact the

    technique supports of our company.

    3.9 version

    Function: To get the version of the software.

    Format:

    version

    Description:

    To display the system version, and SNMP version.If the system reports any error, please contact and give the version numbers to

    technique supports of our company.

    For example:System Version:

    Fiber Transceiver NMS SNMP Agent Software-Version V2.2 Sep 1 2006

    23

  • 8/2/2019 Network Management System User Manul

    24/37

    OptiCin Network Management System User Manual

    Chapter 4 Emanager Network Management Platform

    The main interface of Emanager is shown as below:

    Emanager has functions like User Login, System Configure, Search Device, Data

    Query, Remote Configure, User Management, and Help.

    Menu and Toolbar are detailed below.

    The Menu of Emanager is shown above. It includes User Login, SystemConfigure, Search Device, Data Query, Remote Configure, User Management, andHelp. User Login provide function to identify user, and ensures the security of thesystem. With System Configure, user can edit equipment nodes in equipment-tree toarrange the network equipment according to its essentiality or location, arrange warning

    24

  • 8/2/2019 Network Management System User Manul

    25/37

    OptiCin Network Management System User Manual

    messages, and back up the database. With Search Device, user can search newequipment. User can query the warning messages and landing log. With RemoteConfigure, use can set parameters of an equipment. With User Management, users can

    be managed.

    1 Toolbar

    Mostly used tools are provided in the Toolbar, which facilitates users work. User

    can also use right button of the mouse to manage the system.

    2 Popup Menu

    1. Select the device node, and right clickit, and a menu will popup, allowinguser to set system.

    2. Disable agent device: Select "Disable

    agent device" if user doesnt want to

    manage it temporarily, then the item

    will change to Enable agent device ,

    what user can use to activate the device

    so that it can be managed.

    3. Modify IP address: User can

    set/change IP address of current

    selected device node. Select the node in

    the managing tree, right click it and

    select " Modify IP address "in the

    popup menu, then a dialog will appear.

    Enter the IP address that needed to be

    changed to. If the input is incorrect or

    operation is not successful, system will

    give error massages.(Because this is a

    synchronous operation, after OK is

    clicked, it may need some time to finish

    and close the dialog.) After the Agent IP

    is changed, it can work only after the

    agent computer is rebooted. It may

    bring some exception unexpected, so

    user should be very carefully to use this

    25

  • 8/2/2019 Network Management System User Manul

    26/37

    OptiCin Network Management System User Manual

    command.

    4. Set Trap address: To set/change the IP address sent by Trap of the current selected

    agent node, this IP address is the IP address of the computer where the

    Emanager is installed. User can set 3 IP address, so that the networkmanagement agent module can send messages, including error messages, to

    the IP address. Be sure the IP address is set correctly, otherwise Emanager

    cannot receive Trap massages from networks managed module. After

    changing Trap address, user need to log on the system through Telnet, and

    reboot the system with "reboot" command.

    5. Find warning record: To check warning messages of the current selected agent

    device.

    6. Watch agent: Select and right click the device node in the managing-tree, andselect " Watch agent ". This command should be used to screen the error

    status windows of some agent module, such as remove the status of some

    module, and take the current status as normal status.

    7. Refresh agent: To get new information from the selected agent device node, select

    and right click the node in the managing-tree, then select " Refresh agent ".

    System will check the agent status every 100 seconds. This command is also

    usedto get and refresh the current status of the agent node.

    8. Confirm status: If user changes some settings, NMS may keep giving warning

    messages. If the setting is correct, select this item in the popup menu, and the

    26

  • 8/2/2019 Network Management System User Manul

    27/37

    OptiCin Network Management System User Manual

    system will accept it as normal status.

    9. Delete agent device: To delete the selected agent node.

    3 Enter and Exit of the system

    Only after logging on, can user operate on the system. If user has not logged on, he

    can not do any operation work. User can log on with his own usenam, right click the

    in the taskbar and select the first item to quit management. Another user can double

    click the icon, enter the correct usename and password to log on the system, and do

    management work.

    4 User Management

    1. Add user(Only for superuser)

    Select "User Management " -> "Add User", the a dialog will appear, enter

    username, authority, and password, then click "Modify". If the user has existed

    already, system will not allow to add user with the same username.

    27

  • 8/2/2019 Network Management System User Manul

    28/37

    OptiCin Network Management System User Manual

    2. Delete user(Only for superuser)

    Select "User Management" -> "Delete User", a dialog will appear. Enter the

    username you want to delete, when system ask you confirm, click "Yes" to delete or

    "No" to cancel.

    3Modify the purview of user(Only for superuser)

    Click"Modify Purview" in the Toolbar, a dialog will pop up. Enter the username

    and choose authority, then click" Modify ".

    4Modify the password of user

    Click "Modify Password" in the Toolbar, a dialog will pop up. Enter the

    username,old password and new password, then click Modify. If the old password

    is incorrect, the system will give the clew message.

    5 Search networks equipment

    5.1 Hand search

    Click"Manual" in the Toolbar or select from the Menu, a dialog will popup. Enter

    the IP address you want to search in the node IP entry box, and click "search" to

    search, or "cancel" to cancel. If system finds a device, a new ialog will appear, as

    shown as below.

    28

  • 8/2/2019 Network Management System User Manul

    29/37

    OptiCin Network Management System User Manual

    Enter the agent node name, location, managing-status(whether to be managed or

    not), high temperature threshold, and low temperature threshold, then click

    "Confirm", and it will be added into the managing-tree.

    5.2 The setting of Auto Search

    If user doesnt know the exact IP address, user can enter the IP address or a range

    of some IP addresses. Quit, then system can automatically search IP address.

    5.3 Auto Search

    Select Search Device -> Auto Search, then system will automatically search IP

    address in the IP range set above. When new devices are found, system will append it to

    the end of the managing-tree. System searches device asynchronously, so user can also

    do some other work at the same time, and the searching process is shown in the statusbar.

    29

  • 8/2/2019 Network Management System User Manul

    30/37

    OptiCin Network Management System User Manual

    6 Inquire, Backup, Clear to alarm data or to landing log.

    6.1 Inquire alarm records

    Select and right click a device node in the managing-tree, and select Find warningrecord in the popup menu. A dialog will pop up, showing all serious warning

    messages. User can choose or enter the condition to query the result. User can also

    select the tool from the Menu or Toolbar, to check warning records. When the

    dialog appears, enter the agent serial number to check.

    6.2 Inquire landing log

    Select item in Menu or click button in the Toolbar, a dialog will popup. Then edit

    query condition to search the result.

    30

  • 8/2/2019 Network Management System User Manul

    31/37

    OptiCin Network Management System User Manual

    6.3 Datas backup

    Select Backup Database in the System Configure menu, system will backup

    database to the folder named databak. User can backup database everyday. If it has

    been backed up already, the old backup file will be replaced.

    6.4 Datas clear

    Clean Data is used to clean the warning-message table and log table, so that

    system can have more recourse. System automatically clean the two tables every 15

    days, but user can also set how often to delete them. When entering the data cleaning

    dialog, user can set the condition and delete those records.

    6.5 Adjust the control equipment

    This is used to move one node to another place, or move an unknown device node

    to another place.

    7 The picture notes of control tree nodes

    ------------------ The device works well.(Green icon)

    ------------------ Warning. (Yellow icon)

    ------------------ Serious warning. (Red icon)

    ------------------ Device lost. (Yellow icon)

    ------------------ Device is disconnected, needs to be managed. (Red icon)

    ------------------ Device is connected, no need to be managed. (Red icon)

    31

  • 8/2/2019 Network Management System User Manul

    32/37

    OptiCin Network Management System User Manual

    ------------------ Device is connected, no need to be managed. (Yellowicon)

    8 The simulated map of equipment

    This picture simulates the agent nodes. PS1 and PS2 are power supply. If the indicatelight is green, that means it works well; yellow, power supply warning. Temperature is

    shown at the right-bottom corner.

    If a converter card does not exist, then it will be blue. If condition of the electric port

    Link is normal, then it will be green, otherwise gray. If condition of the optical port

    Link is normal, then it will be green, otherwise gray.

    If condition of a link is normal, it will be green; otherwise, gray. If the card is lost, then

    only a blue area is displayed. If a link works well, the Rx light will be green; otherwise

    it will be gray.

    32

  • 8/2/2019 Network Management System User Manul

    33/37

    OptiCin Network Management System User Manual

    Press button1 or button 2 in Chassis: to switch between chassis. At most 4 chassis can

    be connected by up-link and down-link .

    Double click the card panel, a new dialog will pop up, displaying informations about

    the current card. User can change the values. ( After values are changed, it may needmuch longer time to close the dialog, because here software works in synchronization)

    And Double click the agent panel, another dialog will pop up, displaying informations

    about the agent. User can also change the values. ( After values are changed, it may

    need much longer time to close the dialog, because here software works in

    synchronization)

    9 Card Management

    9.1 10/100M card,enable the remote management

    (1) Sketch Map

    (2) New function of local card

    1) Slot mode set: S&F Mode, Converter Mode, Cut Through Mode, Auto Sense Mode.

    2) EPort Auto-negotiation Set: On, Off.

    3) EPort Speed Set: 100Mbps, 10Mbps

    4) EPort Duplex Set: Full, half.

    (3) New function of remote card

    33

  • 8/2/2019 Network Management System User Manul

    34/37

    OptiCin Network Management System User Manual

    1) Slot mode set: S&F Mode, Converter Mode, Cut Through Mode, Auto Sense Mode.

    2) EPort Auto-negotiation Set: On, Off.

    3) EPort Speed Set: 100Mbps, 10Mbps

    4) EPort Duplex Set: Full, half.

    (4) Rate Limit

    The input speed and output speed of the EPort can be set for rate control. It

    includes 4 choice: 1/4, 2/4, 3/4, 4/4 of Eports current speed.

    (5) Loopback Test

    There are three kinds of package numbers to send for loopback test. They are 4, 10,

    and 100. And the result of loopback test will appear in the text area below.

    9.2 Gigabit Card

    (1)Sketch Map

    (2) Information

    1) Slot Information: Slot Type, Slot Module, Slot SN.

    2) Eport Status: Link, Auto-negotiation, Speed, Duplex.

    3) Fport Status: Link, Speed, Duplex.

    (3) Function

    34

  • 8/2/2019 Network Management System User Manul

    35/37

    OptiCin Network Management System User Manual

    1) Line Name

    2) Open/Close the Eport

    3) Slot Reset

    4) EPort Auto-negotiation Set: On, Off.

    5) EPort Speed Set: 1000Mbps , 100Mbps, 10Mbps6) EPort Duplex Set: Full, half.

    9.3 Dual power ports media converter

    (1) Sketch Map

    (2) Information

    1) Slot Information: Slot Pose, Slot Type, Slot SN, Line Name, Trouble Shift.

    2) Eport Status: Link, Auto-negotiation, Speed, Duplex, Rate Limit, Tag.

    3) Fport Status: Link, Speed, Duplex.

    (3) Function

    1) Line Name

    2) Trouble Shift: Enable, Disable. If there is an error occur on the Fport or the Fport is link down,

    the Eport will be closed. And if the Fport become normal, the Eport will be opened again.

    3) Open/Close the Eport

    4) Slot Reset

    5) EPort Auto-negotiation Set: On, Off.

    6) EPort Speed Set: 100Mbps, 10Mbps

    7) EPort Duplex Set: Full, half.

    35

  • 8/2/2019 Network Management System User Manul

    36/37

    OptiCin Network Management System User Manual

    8) Rate Limit: 32Kbps * N. If the Eports current speed is 10Mbps, N is between 1 and 320. And

    if the Eports current speed is 10Mbps, N is between 1 and 3200.

    9) Tag: Enable, Disable.It is used for 802.1Q VLAN.If the package the Eport received includes

    tag, the Eport should enable tag. And if the package the Eport received includes untag, the

    Eport should disable tag.Chapter 5 Web Management

    1 User Login

    Open the IE, enter the IP address in the URL, http://192.168.0.168 for example, a

    dialog will popup.

    The user name is admin, and the default password is admin. And if you login

    successfully, you can change the password for the user admin by web.

    If you login successfully, you can manage the system by web. Wait a moment, the

    status of chassis and cards will appear, such as below:

    36

  • 8/2/2019 Network Management System User Manul

    37/37

    OptiCin Network Management System User Manual

    2 Main Function

    1) Device Status: The web can show 4 chassis and 60 cards. And the pictures showed is the sameas the status of the object. The web will refresh every 5 seconds. And the pictures will be

    changed in time, if the status of the chassis or cards have changed. If you want to request the

    information of the card, please click the card picture.

    Note: If you click Device Status again, please wait a moment, for the web is getting the status of

    chassis and cards again.

    2) System Information: Request the information of system.

    3) Agent Configuration: Request/Configure the agent module, such as name, location,

    contact,trap address, and temperature threshold of chassis. Request the IP address and current

    temperature of the agent module.

    4) IP Configuration: Request/Configure the agent module, such as IP address, subnet mask,

    and gateway.

    5) Trap Log: Request the warning records, such as the abnormal status of chassis and cards. If the

    log time is incorrect, please set the systems time by the timesync in the same web.

    6) LEDs Hint: The description of the pictures in the Device Status web.

    7) Password Update: Password changed for the user admin.

    8) FTP Upgrade: When system is running this command, it should not be stopped, for example ,

    to reboot the system. Otherwise, unexpected error may occur, and the system may not be able

    to start anymore. If this happens, please contact the technique supports of our company.

    9) System Reboot: Reboot the system to take configuration effect